You are on page 1of 8

+1-205-614-8601 (tel:+1-205-614- Search here..

8601)

Engineering & Design (https://empoweringpumps.com/blog/category/engineering-design/)

(/) Maintenance & Reliability (https://empoweringpumps.com/blog/category/maintenance-reliability/)

Pumps & Operations (https://empoweringpumps.com/blog/category/pumps/)

Industry News (https://empoweringpumps.com/blog/category/news/)

Knowledge Shared (https://empoweringpumps.com/blog/category/knowledge-shared/)

Connect with Us (https://empoweringpumps.com/about/)

NPSH MARGIN — HOW MUCH?


Home (https://empoweringpumps.com/) » NPSH Margin — How Much?

Search here..

(https://servedbyadbutler.com/redirect.spark?
MID=167973&plid=1548582&setID=205919&channelID=0&CID=564268&banID=520452868&PID=0&textadID=0&tc=1&mt=1625581453395299&sw=1920&sh

Industry Topics (https://empoweringpumps.com/blog/category/pump-topics/) March 5, 2017

(https://servedbyadbutler.com/redire
MID=167973&plid=1548585&setID=20

Latest Articles

Remarkable power saving


with SALOMIX™ agitator
(https://empoweringpumps.com/su
remarkable-power-saving-
with-salomix-agitator/)
Energy Efficiency
(/blog/category/energy-
efficiency)

Rubber Check Valves Offers


Many Benefits For Processing
Harsh Fluids
(https://empoweringpumps.com/pr
benefits-of-rubber-check-
valves-for-processing-harsh-
fluids-extreme-weather/)
Water & Wastewater
(/blog/category/water-
wastewater)

NPSH Margin — How Much? Tsurumi B Series pumps


integral to Aquascape’s
overhaul of a 1-acre pond at
the Mabery Gelvin Botanical
By: Randal Ferman (https://empoweringpumps.com/author/randal-ferman/) Gardens in Illinois
(https://empoweringpumps.com/ts
Author: Randal Ferman (https://empoweringpumps.com/industry-pros/randal-ferman/) b-series-pumps-integral-to-
aquascapes-overhaul-of-a-1-
acre-pond-at-the-mabery-
A word on the terminology: Net Positive Suction Head (NPSH) is the sum of the total static plus kinetic pressure gelvin-botanical-gardens-in-
minus the liquid vapor pressure, at the pump suction nozzle or impeller entry, expressed in terms of ‘head.’ illinois/)
Confusion may occur if one does not know that there are two basic NPSH parameters to consider. One is the Water & Wastewater
(/blog/category/water-
NPSH of the system, and this is commonly referred to as NPSH Available or NPSHA. The other is the NPSH
wastewater)
Required by the pump, or NPSHR.

(https://servedbyadbutler.com/redire
MID=167973&plid=1548590&setID=20

Related Categories

Industry Topics
(https://empoweringpumps.com/blo
topics/)
Maintenance & Reliability
(https://empoweringpumps.com/blo
reliability/)
(https://empoweringpumps.com/wp-content/uploads/2017/03/Figure-1-Component- Pumps & Operations
parts-of-NPSHA.jpg)
(https://empoweringpumps.com/blo
Figure 1. Component Parts of NPSHa

Figure 1 above illustrates the component factors of NPSHA. In this chart, atmospheric pressure is dominant but in
other systems the other factors may have relatively greater or lesser importance. In a system open to
atmosphere, the liquid surface elevation above or below the first stage impeller and estimated intake friction
losses may be used in lieu of a pressure reading at the pump intake. Convert pressures readings to head, in units
of meters or feet, by dividing by the specific weight. Pump texts, and other publications show how and where the
readings are taken and how to perform the calculations.

Determining NPSHR requires testing the pump over a series of carefully controlled flow and suction conditions in
a laboratory or factory test facility. For some pump types, such as larger size open pit vertical pumps, a full scale
unit NPSHR test is very often not practical. Scale model pump testing may be the most practical means of (https://servedbyadbutler.com/redire
MID=167973&plid=1548586&setID=36
obtaining the NPSHR data. The accepted industry standard is that, at a given rate of flow, NPSHR represents the
level at which 3% degradation in pump total head occurs at the first stage impeller. The NPSHR characteristic
curve representing 3% head drop is also known as ‘NPSH3.’ Some manufacturers publish their NPSHR curves, or
portions thereof, with margin above NPSH3.

A typical set of pump performance curves at a fixed operating speed, including NPSHR versus rate of flow, are
shown in Figure 2 below.
(https://empoweringpumps.com/wp-content/uploads/2017/03/Figure-2-Pump-
performance-characteristics.jpg)
Figure 2. Pump performance characteristics

Some additional information on the chart is shown for reference, including a curve of NPSHA, the preferred
operating range (POR), the allowable operation range (AOR), and identification of the best efficiency point (BEP)
flow.

A few characteristics of the NPSHR curve deserve mention. At its left side the curve begins not at zero, but at
some intermediate flow. This intermediate flow may be the lowest flow for which a reference pump was tested,
below which the pump experienced heavy internal recirculation and elevated levels of vibration. The low flow end
of the NPSHR curve may, in fact, represent the pump’s minimum continuous flow.  Then from left to right, the
curve continues with a mostly shallow rise characteristic, or sometimes dipping, and then rising gradually towards
Best Efficiency Point (BEP) flow. Beyond BEP flow the NPSHR curve climbs steeply. The high NPSHR often
effectively limits the pump’s maximum flow capability.

It is important to understand how the system’s NPSHA varies across the range of pump operation. This may
influence the pump selection, the intake piping and the necessary NPSH Margin. Intake friction losses vary with
the rate of flow, and can be significant with long lengths of piping and a number of fittings. Changes in overall
system pressure or changes in the liquid elevation above the pump intake impeller directly add or subtract from
the NPSHA. A curve of the system NPSHA as shown at the top of Figure 2, can be determined by the process
engineer. For a vertically suspended pump placed in an open tank or sump, the minimum NPSHA is determined
by the minimum submergence of the pump’s intake impeller. In such an arrangement, the NPSHA can normally
be assumed constant for a given submergence and at any rate of flow.

It is important to understand uncertainties in the system resistance and process head requirements as a function
of flow, including allowance for the as-built conditions. The pump’s rated head-flow point will normally have a
unilateral ‘plus’ tolerance. The operating point or operating range of a rotodynamic (centrifugal/mixed flow/axial
flow impeller) pump will be determined by the intersection of the system characteristic curve and the pump head-
flow curve.

In the range of flow greater than the pump’s Best Efficiency Point (BEP), NPSHR rises. Of particular interest is the
intersection of the NPSHA and NPSHR curves which defines the highest rate of flow for which the pump can safely
operate. As the rate of flow increases, NPSHR climbs steeply and may quickly exceed the NPSHA. This condition is
to be avoided. At the very least, the pump will lose head and fall short on hydraulic performance demand.
Vibration levels increase. Significant cavitation and erosion damage may result.  In some instances, cavitation can
lead to system instability and severe hydraulic transients (water hammer). Insufficient NPSHA may cause the
pumped liquid to flash into vapor causing loss of prime. Inside the pump, close running clearances may run dry
and catastrophic damage is a real possibility.

How do we define ‘NPSH Margin’? There are two ways. One way is to express NPSH Margin as the ratio of [NPSHA
divided by NPSHR]. Another way is to express NPSH Margin in absolute terms as the difference of [NPSHA minus
NPSHR]. For instance, an NPSH Margin ratio of 1.1 indicates the NPSHA is 10% above the NPSHR. Alternatively, say
the value of NPSHR at a given rate of flow is 10 meters and the NPSH Margin is 1 meter. These two example
expressions of NPSH Margin are equivalent. Both ways of expressing NPSH Margin are used in practice, although
for higher energy pumps where the value NPSHR may be high, an NPSH Margin ratio is more commonly used.
A margin ratio of 1.0 means there is sufficient NPSHA for operation of the pump, but in theory, there is zero
margin. In practice, even with ‘zero margin,’ the suction impeller may actually have margin. With a vertical
condensate pump in a suction barrel, for instance, it is common practice to specify 0.0 NPSHA at the suction
nozzle. The liquid height in the barrel provides a static head of NPSHA to the pump intake impeller. Also, the zero
margin condition would be specified for the highest expected rate of flow – a condition that may or may not ever
be seen in actual operation. At rates of flow less than the maximum, the NPSHR will be lower and the NPSH
Margin will exceed 1.0.

In hydrocarbon applications, the cavitation behavior is not so abrupt and unforgiving compared with that of cold
water. With decreasing suction pressure the pump loses performance more gradually and even when the NPSH
margin ratio drops below a value of 1.0, the pump may still operate satisfactorily. The standard API 610 / ISO
13709 Centrifugal Pumps for Petroleum, Petrochemical and Natural Gas Industries disallows a hydrocarbon
correction which would otherwise reduce the NPSHR, for shop NPSH tests on water. This, in effect, provides NSPH
margin.

What are the factors that can affect NPSH Margin? To preface an answer to this, there are issues inherent in the
design and selection of the pump itself, and then there are issues that relate to the properties of the fluid being
pumped and to the operation of the pump.

The impeller material, in addition to its compatibility with the pumped liquid properties, must be appropriate for
the velocity of flow. An index for this is the peripheral tip speed (velocity) at the impeller eye, and in terms of the
potential for cavitation erosion damage, the impeller tip speed, coupled with liquid density, are primary factors.

The impeller vane design at the inlet may also factor into NPSH Margin. Impellers with a high level of suction
performance capability are sensitive, from the standpoint of cavitation and vibration, to operation at off-BEP flow
conditions. The key parameter for pump suction performance is Suction Specific Speed, S (NSS). Values of S > 210
metric (NSS > 11,000 in U.S. customary units) may require closer attention to pump operating range, depending
upon size of the pump, its speed and other design and application factors.

What level of NPSH margin should be specified? There are numerous variables that enter in and there is no one-
size-fits-all answer to this. Traditionally manufacturers, engineering firms and consultants specify NPSH Margin
recommendations, often based on sound experience. As one might expect, NPSH Margin values for a given
application based on information provided by different sources is not always consistent.

The Hydraulic Institute’s publication ANSI/HI 9.6.1-2012 Guideline for NPSH Margin provides specific values and
margin ratios, for common pump application categories. Table A (below) provides selected values from this
guideline applicable to the pump’s Allowable Operating Range (AOR). The HI guideline provides NPSH Margin
recommendations for other industries and application categories, as well as additional values for the Preferred
Operating Range (POR), in the range closer to the BEP flow. It should be noted that the values provided in the HI
publication are not normative and the use of other margin values may be justified.

Is there a benefit to specifying a greater NPSH Margin? Maybe ‘yes,’ and quite possibly ‘no.’ It depends primarily
upon two separate issues. One – do the uncertainties in the pump system characteristics, interactions and other
unknowns warrant a greater NPSH Margin? Or two – does adding to the NPSH Margin improve pump
performance and/or reliability? To increase the NPSH Margin either additional NPSHA must be designed into
system or a pump with a lower NPSHR must be selected.

Building in additional NPSHA into a system may require larger piping to reduce intake friction losses, elevating
tank or pressure vessel liquid levels or placing pumps at a lower elevation setting. These design measures add to
the capital cost of the system.

Selecting a pump with a higher level of suction performance might possibly lead to operational compromises. The
pump with a higher value of S (NSS) will almost certainly have a narrower window of operation with respect to
acceptable vibration levels, seal and bearing longevity, and impeller cavitation erosion life.

Alternatively, lower NPSHR could be achieved by selecting a pump with a slower rotational speed. This pump
option will cost more, but it may be a lot less expensive than attempting to alter the intake piping design.

Otherwise, an incremental increase of the NPSH Margin, especially if there is already an NPSH Margin ratio
greater than 1.0 at the normal operating conditions, will probably not measurably improve pump performance or
reliability. Typical NPSH Margin ratios are in the range of 1.0 to 1.3; a few are greater than this. But to fully
suppress cavitation may require an NPSH Margin ratio of 4.0 or higher depending on the operating flow range.
For most applications, this is simply not practical.

Table A. Selected NPSH Margins from ANSI/HI 9.6.1-2012 Guideline for NPSH Margin
NPSH Margin for the AOR; select
Industry Application the greater value

Petroleum /
Typical, except vertical canned pumps 1.1 ratio or 1.0 m (3.3 ft)
hydrocarbon process

1.1 to 1.2 ratio or 0.6 m (2.0 ft) to 1.0


Chemical process Typical m (3.3 ft)

Electric power Circulating / cooling water 1.0 m (3.3 ft)


generation

Electric power
generation Boiler feed < 250 kW/stage 1.3 ratio

Water Typical, stainless steel or aluminum-bronze 1.1 ratio or 1.5 m (4.9 ft) minimum
impeller, < 75 kW/stage

Typical for pumps in open systems (not 1.0 ratio up to a 1.1 ratio or 0.6 m (2.0
Building services pressurized) ft)

General Often a standard catalog pump 1.1 ratio or 1.0 m (3.3 ft)

Certain applications such as high pressure water injection pumps, pipeline pumps, nuclear service pumps, high
suction performance, large custom engineered pumps and high energy designs are beyond the HI document’s
scope and require individual attention.

Does the appropriate NPSH Margin eliminate cavitation? An NPSH Margin ratio of 2 to 10 – often greater than a
ratio of 4 – would be required to suppress all cavitation. It depends mainly upon the inlet geometry of the pump
and the range of operation. For most applications, the pump will tolerate some cavitation without compromising
reliability. For most applications it is impractical and unnecessary to completely suppress all cavitation.

NPSH Margin can only be determined by understanding the performance of both the pump and system. An
appropriate NPSH Margin will allow the pump to operate over the range of flows required by the process, will
keep the pump from cavitating excessively or losing suction prime and it should not add excessively to the capital
cost of the system.

For an independent evaluation of the NPSH Margin for your pumping system, contact an experienced
consulting engineer who can help with your specific application.

RELATED ARTICLES

(https://servedbyadbutler.com/redirect.spark?
(https://empoweringpumps.com/sulzer-(https://empoweringpumps.com/proco-(https://empoweringpumps.com/tsur
MID=167973&plid=1548591&setID=440527&channelID=0&CID=564271&banID=520452883&PID=0&textadID=0&tc=1&mt=1625581461228659&spr=1&hc=e
remarkable-power-saving-with- benefits-of-rubber-check-valves- b-series-pumps-integral-to-
3-questions-ask-considering- salomix-agitator/) for-processing-harsh-fluids- aquascapes-overhaul-of-a-1-acre-
sealless-pump/) extreme-weather/) pond-at-the-mabery-gelvin-
botanical-gardens-in-illinois/)

3 QUESTIONS TO REMARKABLE
RUBBER CHECK
ASK YOURSELF POWER SAVING TSURUMI B SERIES
VALVES OFFERS
WHEN WITH SALOMIX™ PUMPS INTEGRAL
MANY BENEFITS
CONSIDERING A AGITATOR TO AQUASCAPE’S
FOR PROCESSING
SEALLESS PUMP (HTTPS://EMPOWERINGPUMPS.COM/SULZER- OVERHAUL OF A 1-
HARSH FLUIDS
REMARKABLE-
(HTTPS://EMPOWERINGPUMPS.COM/DICKOW- ACRE POND AT THE
(HTTPS://EMPOWERINGPUMPS.COM/PROCO-
3-QUESTIONS-ASK- POWER-SAVING- MABERY GELVIN
BENEFITS-OF-
CONSIDERING- WITH-SALOMIX- BOTANICAL
RUBBER-CHECK-
SEALLESS-PUMP/) AGITATOR/) GARDENS IN
VALVES-FOR-
ILLINOIS
PROCESSING-
SPONSORED
(HTTPS://EMPOWERING
Sulzer was looking for a field HARSH-FLUIDS- B-SERIES-PUMPS-
test installation for the new
EXTREME- INTEGRAL-TO-
SALOMIX SSF100 side-
mounted agitator. A Swedish WEATHER/) AQUASCAPES-
customer was interested… OVERHAUL-OF-A-1-
Learn how Rubber Check
ACRE-POND-AT-THE-
Valves can help municipalities MABERY-GELVIN-
prepare for extreme weather BOTANICAL-
and other challenging
GARDENS-IN-
conditions.
Natural disasters
remind us of…
ILLINOIS/)

After almost half a century of


delighting visitors at a forest
preserve in Illinois, a large
man-made pond that is…

See More Articles (https://empoweringpumps.com/blog/category/pump-topics/)

RELATED WHITEPAPERS

10 ESSENTIALS VERDERFLEX WHY PRESSURE ACCURATE,


FOR SELECTING A DURA 65 MANAGEMENT? RELIABLE,
DOUBLE DATASHEET (HTTPS://EMPOWERINGPUMPS.COM/WHITE-
EFFICIENT PUMPS
DIAPHRAGM (HTTPS://EMPOWERINGPUMPS.COM/WHITE- PAPERS/CLA-VAL- THAT HANDLE
PUMP PAPERS/VERDER- WHY-PRESSURE- PARTICULATES
(HTTPS://EMPOWERINGPUMPS.COM/WHITE-VERDERFLEX- MANAGEMENT/) FOR WATER &
PAPERS/VERDER- DURA-65- There are many ways and
WASTEWATER
10-ESSENTIALS- DATASHEET/) reasons that pressure can TREATMENT AND
FOR-SELECTING-A- Verderflex Dura 65
and should be managed in a REVERSE OSMOSIS
network from source to tap.
DOUBLE- Peristaltic Hose Pump The aim is to create…
(HTTPS://EMPOWERIN
DIAPHRAGM- Designed for applications PAPERS/WANNER-
such as Metering, Dosing,
PUMP/) and Transfer duties (strong
ACCURATE-
In almost all factories you advantages on sludges, RELIABLE-
can find at least a couple of slurries and abrasives) EFFICIENT-PUMPS-
Benefits Class-leading…
air-operated double THAT-HANDLE-
diaphragm pumps. Not
always in the heart of the
VIEW WHITEPAPERS (/WHITE-PAPERS/) PARTICULATES-
process, and… FOR-WATER-
WASTEWATER-
COMMENTS TREATMENT-AND-
REVERSE-
4 RESPONSES TO “NPSH MARGIN — HOW MUCH?”
OSMOSIS/)
Compact, Seal-less Pumps
Mikhail Gaibov
November 20, 2017 at 7:45 pm (https://empoweringpumps.com/npsh-net-positive-suction-head/#comment-279)
Reduce Costs and Provide
Dependable Performance
The unique seal-less,
Thank you for a very useful article! Each pump engineer & professional must understand the content for to prevent cavitation
multiple-diaphragm
& pumps design
damage/erosion. In this case your pumps will have longer service life. If not,- you must be ready to replace often the pumps
of Hydra-Cell
seals, impellers,
offersbearings,
distinct
becuse of the wrong equipment selection benefits throughout many
applications in the water…
Reply

Sirelkhatim Nugud
November 25, 2017 at 3:30 pm (https://empoweringpumps.com/npsh-net-positive-suction-head/#comment-280)

Very useful article, is there any difference between API & ANSI regarding the NPSH margin?

Reply

Randal Ferman (http://ekwestrel.com)


November 27, 2017 at 11:12 am (https://empoweringpumps.com/npsh-net-positive-suction-head/#comment-281)

The standard API 610 states that the purchaser, in consultation with the vendor, should consider the appropriate NPSH margin for the
anticipated range of pump operation.

ASME B73.1-2012 (horizontal ‘ANSI’ pump dimensional standard) specifies the greater of a minimum margin of 3 ft (0.9 m) or a margin ratio of
1.2, and refers to the Hydraulic Institute standard ANSI/HI 9.6.1 NPSH Margin for additional application information.

Reply

Rafael Ocampo
March 10, 2021 at 4:05 pm (https://empoweringpumps.com/npsh-net-positive-suction-head/#comment-47366)

Dear Mr Ferman:

A value of NPSH margin ratio could be calculated at the normal operating conditions or at any other flowrate handled by the pump. However, in almost
all the recommendations the MSCF is determined starting from suction specific speed and by definition Nss should be calculated for the BEP capacity.
Also, MSCF is expressed as percent of the BEP flowrate, then for the determination of MSCF, should the NPSH calculations should be referred to the BEP
capacity also?

I would appreciate your comments. Thank you.

Reply

LEAVE A REPLY
CANCEL REPLY (/NPSH-NET-POSITIVE-SUCTION-HEAD/#RESPOND)
Your email address will not be published. Required fields are marked *

Comment

Name *

Email *

Website

Save my name, email, and website in this browser for the next time I comment.

POST COMMENT
(https://servedbyadbutler.com/redirect.spark?
MID=167973&plid=1548583&setID=427157&channelID=0&CID=564268&banID=520452868&PID=0&textadID=0&tc=1&mt=1625581453399159&sw=1920&sh

SIGN UP FOR OUR NEWSLETTER!


*First Name *Email Company

*Last Name *Phone Industry

SIGN UP

Contact Information Sitemap Latest News


social@empoweringpumps.com About Us Remarkable power saving with
(mailto:social@empoweringpumps.com)(https://empoweringpumps.com/about/)
SALOMIX™ agitator
(/) Empowering Industry Podcast (https://empoweringpumps.com/sulze
+1-205-614-8601 (tel:+1-205-614- (/podcast) remarkable-power-saving-with-
8601) salomix-agitator/)
Events & Training (/events)
Partner Hub (/companies) Rubber Check Valves Offers Many
Benefits For Processing Harsh
Media Kit
Fluids
(https://empoweringpumps.com/about/download-
media-kit/) (https://empoweringpumps.com/proc
benefits-of-rubber-check-valves-
Subscribe to our eNewsletter
for-processing-harsh-fluids-
(https://empoweringpumps.com/enewsletter-
archive/) extreme-weather/)
Industry Pros (/industry-pros) Industry Person of the Week- RJ
Editorial Guidelines Russell
(https://empoweringpumps.com/indu
(https://empoweringpumps.com/editorial-
guidelines/) person-of-the-week-rj-russell/)
Opt in / Opt Out Preferences
(https://empoweringpumps.com/opt-
in-opt-out-preferences/)

You might also like