Professional Documents
Culture Documents
Tag Qty
BP-01/02 2
Pump Information
Pump Notes
Motor Information
Motor Notes
Suction Diffuser
4 X 3 FLG X FLG SUCTION DIFFUSER
Page 1 of 9
Page 1
August 23, 2018
Job 922 HOTEL AREQUIPA
Client
Engineer
Tag BP-01/02
Page 2 of 9
Page 2
August 23, 2018
Suct Disc B1 B2 B3 B4 H1 H2 D
3.00 2.50 2.25 21.32 5.88 6.62 7.00 7.50 0.625
Job 922 HOTEL AREQUIPA
Client
Engineer
Tag BP-01/02
Page 3 of 9
Page 3
August 23, 2018
Performance Curve
Curves based on shop test using clear cold water on a closed loop system at a temperature of not over 85°F at specific gravity 1.0
Performance guaranteed at operating point indicated only.
Page 4 of 9
Page 4
MULTI-FUNCTION VALVE
Product Specifications
SINCE 1981
Technical
Pressure:
Class125
Working Temp:
-20°C -120°C
-4°F -248°F
Flange to:
ANSI B16.1
Dimensions (mm/in)
√
0200- 0250- 0300- 0400- 0500- 0600- 0800- 1000- 1200-
MFV
150F 150F 150F 150F 150F 150F 150F 150F 150F
NPS 2 2 1/2 3 4 5 6 8 10 12
50 65 80 100 125 150 200 250 300
DN
1.97 2.56 3.15 3.94 4.92 5.90 7.88 9.84 11.81
213 250 254 368 407 457 546 648 762
L
8.39 9.84 10 14.49 16.02 17.99 21.50 25.51 30.00
226 240 257 295 330 352 530 584 609
H1
8.90 9.45 10.12 11.61 12.99 13.85 20.87 22.99 23.98
251 265 282 320 363 380 579 663 711
H2
9.88 10.43 11.10 12.60 14.29 14.96 22.80 26.10 27.99
180 250 350 450
Ød
7.09 9.84 13.78 17.72
M 6.35 - 1/4’’ NPT
Products Specifications
No. Name Material
working pressure Class125
1 Body DI
∅d 2 Disc
working Temp.
DI+EPDM
EPDM -20℃~+120
Medium W. O. G
7 6 5 3 Shaft SS410
Shell Test 2.5 MPa
4 Cover DIFlanged acc.to ANSI B16.1
4
5 Gasket EPDM
3 6 Scale Plate Plastic
7 Handwheel Carbon Steel
2
H2
1
Technical
H1
N Pressure:
Class250
Working Temp:
∅D
∅K
DN
-20°C-120°C
-4°F -248°F
2-M
T T Flange
7 to:
Handwheel 1 Carbon s
n-∅P L ANSI B16.1
L1 6 Scale plate 1 Plasti
5 Gasket 1
Dimensions (mm/in) 4 Cover 1 DI
√
0200- 0250- 0300- 0400- 0500- 0600-
3
0800-
Shaft
1000-
1
1200-
SS410
MFV
250F 250F 250F 250F 250F 250F 2250F 250F
Disc 250F
1 DI+EPD
NPS 2 2 1/2 3 4 5 6 8 10 12
1200 Body 1 DI
50 65 80 100 125 150 250 300
DN
1.97 2.56 3.15 3.94 4.92 5.90 NO.
7.88 NAME
9.84 Q'TY
11.81 MATERI
213 250 254 368 407 457 546 648 762
L
8.39 9.84 10 14.49 16.02 17.99 21.50 25.51 30.00
309 336 340 439 472 560 691 787 951
L1
12.17 13.23 13.39 17.28 18.58 22.05 27.20 30.98 37.44
226 1/4"NPT
240 257 295 330 352
晏奎
530 flange589
drilled to 691SHANGHAI FLOW V
H1 Class250
8.90 9.45 1"NPT
10.12 11.61 12.99 13.85 20.87 23.19 27.20
251 265 282 320 363 380 579 668 809
H2
9.88 10.43 11.10 12.60 14.29 14.96 22.80 26.30 31.85
180 250 350 450
Ød
7.09 9.84 13.78 17.72
165.1 190.5 209.6 254 279.4 317.5 381 444.5 520.7
ØD
6.5 7.5 8.25 10 11 12.5 15 17.5 20.5
127 149.4 168.2 200.2 235 269.8 330.2 387.4 450.9
ØK
5 5.88 6.62 7.88 9.25 10.62 13 15.25 17.75
401.32 444.5 485.14 607.06 645.16 723.9 767.08 807.72
T
15.8 17.5 19.1 23.9 25.4 28.5 30.2 31.8
M 6.35mm - 1/4’’ NPT
N 12.7mm - 1/2’’ NPT 25.4mm - 1’’ NPT
Features
Low Pressure Drop
The multi-function valve streamlined design results in low pressure drop making it
extremely energy efficient.
Control
Greater range of control allows precise flow control versus On-Off throttling valves.
Positive Shut-Off
Without valve chattering. These valves are positive shut-off valves, when using MFV
valves, other types of valves are not required
Calibrated Nameplate
The multi-function valve allows you to return to the balance position after shutting
it off.
Durability
Bronze seat and disc with stainless steel stem construction ensure long life and re-
liability.
Design
The multi-function valve is a double regulating, control and shut-off valve with a built
in pressure drop measuring in-line flow. Balancing problems are quite evident in a
system, like central air conditioning plants and in process heat exchangers. The MFV
valve is a combination of a shut-off valve (gate / plug / ball / butterfly valve) plus a
flow regulating (globe style valve), a flow measuring station. It is not merely a valve
but a system control valve in itself. It provides a scientific basis for flow balancing
in a system with database. The valves are used HVAC systems and other process
applications wherever balancing is required. Balancing is done to improve the peifor-
manceof a closed circuit, forced circulation water in the system for heating and coo-
ling. Balancing makes the building provide the desired indoor climate under all opera-
ting conditions at minimum energy cost. Balancing is a matter of adjusting pressure
drops to get the precise required flow of water in a circuit. Balancing reduces energy
costs by almost 10% to 40% by reducing average temperature in a heating system
and increasing average temperature in a cooling system with less energy for pum-
ping. Replacing three valves with one MFV-F (flange) or MFV-G (grooved) valves can
dramatically reduce your up-front material and labor costs
Spring Loaded Clapper
Allows the Multi-function valve to be installed horizontally or vertically upward. ln-line
Serviceability
Allows easy maintenance and replacement without disturbing the piping.
Benefits
1) Using a multifunction valve avoid user’s complaints with unbalanced heating or
cooling systems in different parts of the building.
2) Easy correction of system design and installation errors
3) Better accuracy of flow measurement
4) Economic; system components like boilers/chillers don’t have to be oversized for
possible errors and varying conditions. A balanced system only needs the actually
required flows which is usually less than system when not balanced.
Performance Curves
MFV0200-150F // MFV0200-250F
Performance Curves
MFV0250-150F // MFV0250-250F
Performance Curves
MFV0300-150F // MFV0300-250F
Performance Curves
MFV0400-150F // MFV0400-250F
Performance Curves
MFV0500-150F // MFV0500-250F
Performance Curves
MFV0600-150F // MFV0600-250F
Performance Curves
MFV0800-150F // MFV0800-250F
Performance Curves
MFV1000-150F // MFV1000-250F
Performance Curves
MFV1200-150F // MFV1200-250F
Performance Curves
SINCE 1981
MFV1400-150F
Performance Curves
SINCE 1981
MFV1600-150F
Performance Curves
SINCE 1981
MFV1800-150F
Product Specifications
SINCE 1981
Flo Fab SEP ASME Vortex type Air Separators eliminate air
quickly and efficiently from open and closed loop heating/coo-
SEP
ling systems. Water enters and exits through unique “tangen-
tial” connections, which promote a low velocity swirling effect Performance Limitations
in the center of the unit. Natural centrifugal forces allow the Maximum Design Temperature:
heavier air-free water to move toward the outer edges while 450°F
entrained air is captured within the “eye” of the vortex and re- Maximum Design Pressure:
leased out of the top of the separator. The bubble-free water 150 PSI (2’’-8’’ inlet/outlet)
then exits near the bottom of the unit, protecting the systems 125 PSI (10’’-30’’ inlet/outlet)
against the noise, corrosion, and damage commonly caused
by entrained air. SEP units also include system strainer. *200 & 250 PSIG available
WITH STRAINER
Product Specifications
Flo Fab SEP ASME Vortex type Air Separators eliminate air SEP
quickly and efficiently from open and closed loop heating/coo-
ling systems. Water enters and exits through unique “tangen- Performance Limitations
tial” connections, which promote a low velocity swirling effect
in the center of the unit. Natural centrifugal forces allow the Maximum Design Temperature:
heavier air-free water to move toward the outer edges while 450°F
entrained air is captured within the “eye” of the vortex and re- Maximum Design Pressure:
leased out of the top of the separator. The bubble-free water 150 PSI (2’’-8’’ inlet/outlet)
then exits near the bottom of the unit, protecting the systems 125 PSI (10’’-30’’ inlet/outlet)
against the noise, corrosion, and damage commonly caused
by entrained air. SEP units also include system strainer. *200 & 250 PSIG available
WITHOUT STRAINER
Performance Curves
SINCE 1981
SEP
Pressure Drop Charts Comparing Feet of Head Versus
Flow in Gallons Per Minute for Tangential Flo Fab Air Separators...
With Strainer
Without Strainer
Features
The FLO FAB suction diffusers are designed to reduce space and installation cost by
replacing a long radius elbow, Y strainer and extended entry pipe on the suction side
of the pump. The flow stabilizing vane reduces turbulence and prevents stress and
vibration.
In addition, the suction diffuser strainer removes foreign particles which may be
hazardous for the pump and other system equipment. FLO FAB suction diffusers are
available in a variety of materials recommendation based on the flow media.
Pressure: Class125
Working Pressure: 200 PSI
Working Temp: NBR -12°C~+82°C
-53.6°F~+179.6°F
EPDM -35°C~+135°C
-95°F~+275°F
Medium: W. O. G.
Shell Test: 2.07 Mpa
Flange: ASME/ANSI, B16.1, C125
1 Body 150CI/250DI
2 Cover 150CI/250DI
Perforated
3 SS304
Screen
Wire Woven
4 SS304
Screen
5 O-Ring NBR/EPDM
6 Knob, Bolt WCB
7 Plug WCB
Dimensions (in/mm)
√ Size L1 L1 L2 L2 L3 L3 L4 L4 L5 L5
NPT
(in) (mm) (in) (mm) (in) (mm) (in) (mm) (in) (mm)
2x2 4.5 114.3 4.5 114.3 6.65 169 5.94 151 9.96 253
2.5x2
5 127 5 127 7.52 191 6.57 167 10.63 270
2.5x2.5 19.05mm
3x2 4.5 114.3 7.68 195 6.04 153.6 9.92 252 0.75’’
3x2.5 5.5 139.7
5.5 139.7 8.50 216 7.04 179 11.18 284
3x3
4x3 10.35 263 8.77 223 13.15 334
6.5 165 6.5 165
4x4 10.24 260 8.27 210 12.91 328
5x4
7.5 190.5 7.5 190.5 13.07 332 10 254 15.51 394
5x5
25.4mm
6x4 6.50 165 12.95 329 8.78 223 13.58 345
1’’
6x5 7.99 203
7.99 203 14.45 367 10.70 272 16.65 423
6x6
8x5 7.56 192 9 228.6 13.11 333 12.95 329 19.17 487
8x6 8 203.2 15.47 393 11.69 297 17.91 455
9 228.6
8x8 17.24 438 21.34 542
9 228.6 11.61 295
10x8 19.21 488 21.22 539
11 279.4
10x10 11 279.4 20.75 527 14.17 360 26.69 678 31.75mm
12x8 11.2 280 11.2 280 19.21 488 13.62 346 21.69 551 1.25’’
12x10 11 279.4 14.17 360
12 21.78 553 26.69 678
12x12 304.8 12 304.8 15.35 390
NOTE: LARGER SIZE UP TO 20’’ AVAILABLE
TYPICAL INSTALLATION
Pressure Drop
SINCE 1981
VS Flow Rate
1 2 34 5 6 7 8 910 11
1 2 34 5 6 7 8 910 11
Pressure Drop (ft)
2 ASDGF2502
2
Curve ASDFF2502
Models 2.5 x 2
Dimensions Curve 2.5 x Models
2
Dimensions
Pressure Drop
VS
Flow Rate
Water Service, Clean Basket, 1/32’’ - 1/4’’
Perforated Screen
23.1
10
x
14
&
2.31 12
x
12
0.231
100 1000 10000
Flow Rate (GPM)
2 4 6 8
x1 x1 x1 x1
16 18 20 24
& & &
2 14 14 16 6 8 & 18 20 0 24
x1 x x x x1 x1 x x 4x2 4x
14 14 16 16 18 18 20 20 2 2
2.31
0.231
1000 10000 40000
Product Specifications
RDT
Flo Fab type RDT expansion tanks are designed for use in Hydronic heating/cooling systems to
absorb the expansion force resulting from the changes in temperature of the heating/cooling
fluid. As the system fluid expands, it is forced into the precharged tank to the maximum system
pressure. The precharged air cushion then forces the fluid back into the system as it contracts.
The extra heavy butyl diaphragm keeps the fluid permanently isolated from the precharged air
cushion. This arrangement eliminates water logging and absorption of air into the system. It
also helps prevent air bound terminal units, excessive corrosion, inefficient balancing and pump
cavitation over the life of the system. The large acceptance volume allows maximum storage
and reduction of up to 80% in tank size. Energy consumption is reduced by eliminating unne-
cessary system water volume.