You are on page 1of 1

Our ref.

: P-16290
Rev.01 / Dt:- 06.07.21
TLT ENGG. INDIA PVT. LTD. Client : M/S. Mascot Cement
Technical Data Sheet
Sr. Parameter Unit
1 Project 1250 TPD green field
2 Fan Type RABH FAN ( 1x100%)
3 Blade Type Backward curved
5 Fan Model 20071Z/ 1056

6 Gas flow m3/h 180000


3 50.00
m /s
7 Suction press. mmwc -375
8 Differential press. mmwc 375
9 Total System press. Pa 3823
10 Inlet gas temp. °C 120
11 Mechanical desing temp. °C 260
12 Dust load gm/Nm
3 0.05
13 Inlet gas density kg/m3 0.65
14 No. of inlet Double Inlet
15 Impeller mounting Simply supported
16 Impeller Diameter mm 2110
17 Type of control VFD/ Damper
18 Fan speed rpm 980
19 Fan shaft power kW 224
20 Fan rotor GD^2 kg-m
2 3760
21 Fan efficiency % 84.4
22 Recomm. Motor 250 kW/ 6 pole
23 Bearing type & size (DE/ NDE) Antifriction Roller, 100/ 100, GREASE
85 at 1m with inlet & outlet system connected at
24 Fan Noise Level dBA
site
25 Material of construction
Casing IS 2062 E250 Gr.A/B, 6 mm
Suction Box IS 2062 E250 Gr.A/B, 6 mm
Impeller (Shroud) IS 2062 E250 Gr.A/B, 8 mm
Impeller (Back plate) IS 2062 E250 Gr.A/B, 15 mm
Impeller (Blade) IS 2062 E250 Gr.A/B, 6 mm
Blade liner, hardfacing 3 mm Cr.C H/F on 5 mm MS liner over 100%
working area of blade
Shaft EN-8
Note All above dimensions are subject to change at the time of final design.
Recommended motor, considering 10% margin on fan shaft power with i/l damper closed condition.
Total system Pressure includes all pressure drops.
All above performance parameters subject to tolerance as per IS-4894 / BS- 848.

You might also like