You are on page 1of 2

3700 Series, 50 HP—60 Hz Horsepower Rated

MODEL 3707 3709 3710 3712


Compressor Performance*
Full Load Pressure - psig 100 125 150 175
Capacity at Full Load Pressure - acfm 250 222 196 179
Power at Full Load Pressure - bhp 55.7 55.2 53.2 53.4
Package kW Air-cooled 46.0 45.6 44.0 44.1
Package kW Water-cooled 44.7 44.3 42.7 42.8
Gear Ratio 2.56 2.30 2.06 1.91

Electrical Data (Typical) 200V 230V 460V 575V


Motor hp 50 50 50 50
Motor Nominal Efficiency 93.0% 93.0% 93.0% 93.0%
Nominal rpm 1765 1765 1765 1765
Frame Size (ODP) 326TSC 326TSC 326TSC 326TSC
Service Factor 1.2 1.2 1.2 1.2
Nameplate Amps 138.0 120.0 60.2 48.2
Locked Rotor Amps - Max. 775 674 337 270
Starter Size – NEMA/Amps 200 160 100 100
Electrical Enclosure NEMA 4 NEMA 4 NEMA 4 NEMA 4

Cooling Data
Fluid Flow – gpm 13 12.5 13.7 15
Heat Rejection - Fluid Clr. BTU/min. 1906 1939 1900 1936
Heat Rejection - Aft. Clr. BTU/min.** 456 405 358 327

Air/Fluid Receiver
Fluid Fill Capacity - U.S. Gal. 3.5 3.5 3.5 3.5
Volume - Cubic Feet Air (U.S. Gal.) 10 10 10 10
Rated Pressure - psig 210 210 210 210

Dimensions & Weights w/Enclosure – Uncrated (Crated)


Length - inches 62 (68) 62 (68) 62 (68)
Width - inches 34.5 (49.5) 34.5 (49.5) 34.5 (49.5)
Height - inches 61.5 (76) 61.5 (76) 61.5 (76)
Weight - lbs. 1040 (2370) 2040 (2370) 2040 (2370)
Discharge Connection - in. NPT 1 1/2 1 1/2 1 1/2
Moisture Drain Connection - in. NPT 1/4 1/4 1/4

This document may not be reproduced or distributed without express consent from Sullair.
Page 1 of 2
Issued:5/1/2006
3000 Series 60Hz

MODEL 3707 3709 3710 3712


dBA Ratings at 1 Meter (Typical)
Air-cooled w/enclosure 68 68 68 68
Water-cooled w/enclosure Consult Factory C/F C/F C/F C/F

Water-cooled Series Flow (w/aftercooler)


Flow at 80°F Water in - gpm 9.3 9.3 9.3 9.3
Pipe connection NPT In/Out - inches 3/4 / 3/4 3/4 / 3/4 3/4 / 3/4 3/4 / 3/4
Max./Min. Water Pressure - psig 75 / 25 75 / 25 75 / 25 75 / 25
Water Outlet Temperature °F 110 110 110 110

Cooling Air Flows


Air Flow Water-cooled Fan w/encl. - cfm 730 730 730 730
Water-cooled Vent Fan - hp 1/30 1/30 1/30 1/30
Air Flow Air-cooled Fan - cfm 4800 4800 4800 4800
Air-cooled Fan Motor - hp 1.5 1.5 1.5 1.5

Filter Rating
Inlet Air 99.99% Eff. Per SAE J726C
Main Lubricant Flow Beta 15 = 75 Per ISO 16889

*Capacity per CAGI / PNEUROP PN2CPTC2 (Annex C to ISO 1217.)

NOTE: Data subject to change without notice.

Sullair Corporation
3700 E. Michigan Blvd., Michigan City, IN 46360
Tel: 1-800-SULLAIR FAX: 219-874-1273
www.sullair.com

This document may not be reproduced or distributed without express consent from Sullair.
Page 2 of 2
Issued: 5/1/2006