Features / Benefits
Combination indicator (top and center) for easy identification of blown fuses
High interrupting rating up to 120 kA
Voltage ratings AC 400 - 1500 V
Operating classes gG / gB / aM / gTr / gTF available for all applications
Fuse-bases and accessories available, made of sheet steel base plate with ceramic support
Low power losses and low temperature rise
All fuse-links are entirely corrosion resistant
Gripping-lugs: metal/live for standard application, metal/insulated for increased safety
www.siba.de NH 1
NH SICHERUNGEN/FUSES
Current limiting
NH 2 www.siba.de
SICHERUNGEN/FUSES
NH
The discrimination between two fuse links of diffe- required during such operation is safely achieved by
rent current ratings can only be determined when SIBA LV-fuse-links type aM at low cut-off currents.
considering the service voltage. The degree of discri-
mination in radially operated systems of 1:1.6, as
well as the use of fuse links of the same rated cur-
rent in meshed networks, is only applicable at servi- gTr
ce voltages 1.1 x UN 3.
SIBA LV-fuse-links of duty gTr are with a specific
curve adapted to the load charcterisitc of the trans-
former. Therefore better utilization of the overload
Characteristic stability capacity of transformers is achieved. SIBA transfor-
mer-fuse-links are capable of carrying 1.3-times the
SIBA LV fuse links are extremely resistant to ageing. current rating of a transformer as a continuous load
for minimum 10hrs. The fuse operates within 2hrs.,
They have, without ageing, successfully passed at 1.5-times the current rating of the transformer.
longterm overload tests according to VDE 0636, Characteristic corresponds to VDE 0636/2011.
where a specified cyclic load is applied for a period
of 200 hours at a test current equal to 1.15 times the
fuse rated current.
gB
aM
www.siba.de NH 3
NH SICHERUNGEN/FUSES
NH 4 www.siba.de
SICHERUNGEN/FUSES
NH
www.siba.de NH 5
NH SICHERUNGEN/FUSES
NH 6 www.siba.de
SICHERUNGEN/FUSES
NH
www.siba.de NH 7
NH SICHERUNGEN/FUSES
Size Standard
000 Metal Gripping-Lugs with Combi Indicator IEC 60269-2-1
Rated Voltage AC 500 V / DC 220 V Rated Voltage AC 690 V / DC 220 V
Rated Part No. Weight Pack Rated Part No. Weight Pack
Current Current
[A] [kg/1] [A] [kg/1]
2 20 000 13.2 0.11 10
4 20 000 13.4 0.11 10
6 20 000 13.6 0.11 10 6 20 477 13.6 0.11 3
10 20 000 13.10 0.11 10 10 20 477 13.10 0.11 3
16 20 000 13.16 0.11 10 16 20 477 13.16 0.11 3
20 20 000 13.20 0.11 10 20 20 477 13.20 0.11 3
25 20 000 13.25 0.11 10 25 20 477 13.25 0.11 3
32 20 000 13.32 0.11 10 32 20 477 13.32 0.11 3
35 20 000 13.35 0.11 10 35 20 477 13.35 0.11 3
40 20 000 13.40 0.11 10 40 20 477 13.40 0.11 3
50 20 000 13.50 0.11 10 50 20 477 13.50 0.11 3
63 20 000 13.63 0.11 10
80 20 000 13.80 0.11 10
100 20 000 13.100 0.11 10
Size Standard
00 Metal Gripping-Lugs with Combi Indicator IEC 60269-2-1
Rated Voltage AC 500 V / DC 220 V Rated Voltage AC 690 V / DC 220 V
Rated Part No. Weight Pack Rated Part No. Weight Pack
Current Current
[A] [kg/1] [A] [kg/1]
63 20 209 13.63 0.154 3
80 20 209 13.80 0.154 3
100 20 209 13.100 0.154 3
125 20 001 13.125 0.154 10 125 20 209 13.125 0.154 3
160 20 001 13.160 0.154 10
NH 8 www.siba.de
SICHERUNGEN/FUSES
NH
Size Standard
0 Metal Gripping-Lugs with Combi Indicator IEC 60269-2-1
Rated Voltage AC 500 V / DC 440 V Rated Voltage AC 690 V / DC 440 V
Rated Part No. Weight Pack Rated Part No. Weight Pack
Current Current
[A] [kg/1] [A] [kg/1]
2 20 002 13.2 0.23 3
4 20 002 13.4 0.23 3
6 20 002 13.6 0.23 3 6 20 210 13.6 0.23 3
10 20 002 13.10 0.23 3 10 20 210 13.10 0.23 3
16 20 002 13.16 0.23 3 16 20 210 13.16 0.23 3
20 20 002 13.20 0.23 3 20 20 210 13.20 0.23 3
25 20 002 13.25 0.23 3 25 20 210 13.25 0.23 3
32 20 002 13.32 0.23 3 32 20 210 13.32 0.23 3
35 20 002 13.35 0.23 3 35 20 210 13.35 0.23 3
40 20 002 13.40 0.23 3 40 20 210 13.40 0.23 3
50 20 002 13.50 0.23 3 50 20 210 13.50 0.23 3
63 20 002 13.63 0.23 3 63 20 210 13.63 0.23 3
80 20 002 13.80 0.23 3 80 20 210 13.80 0.23 3
100 20 002 13.100 0.23 3 100 20 210 13.100 0.23 3
125 20 002 13.125 0.23 3 125 20 210 13.125 0.23 3
160 20 002 13.160 0.23 3
Size Standard
1 Metal Gripping-Lugs with Combi Indicator IEC 60269-2-1
Rated Voltage AC 500 V / DC 440 V Rated Voltage AC 690 V / DC 440 V
Rated Part No. Weight Pack Rated Part No. Weight Pack
Current Current
[A] [kg/1] [A] [kg/1]
16 20 003 13.16 0.28 3 16 20 211 13.16 0.44 3
20 20 003 13.20 0.28 3 20 20 211 13.20 0.44 3
25 20 003 13.25 0.28 3 25 20 211 13.25 0.44 3
32 20 003 13.32 0.28 3 32 20 211 13.32 0.44 3
35 20 003 13.35 0.28 3 35 20 211 13.35 0.44 3
40 20 003 13.40 0.28 3 40 20 211 13.40 0.44 3
50 20 003 13.50 0.28 3 50 20 211 13.50 0.44 3
63 20 003 13.63 0.28 3 63 20 211 13.63 0.44 3
80 20 003 13.80 0.28 3 80 20 211 13.80 0.44 3
100 20 003 13.100 0.28 3 100 20 211 13.100 0.44 3
125 20 003 13.125 0.28 3 125 20 211 13.125 0.44 3
160 20 003 13.160 0.28 3 160 20 211 13.160 0.44 3
200 20 003 13.200 0.44 3 200 20 211 13.200 0.44 3
224 20 003 13.224 0.44 3 224 20 211 13.224 0.44 3
250 20 003 13.250 0.44 3 250 20 211 13.250 0.44 3
Dimensions see Page NH 12 + NH 13
www.siba.de NH 9
NH SICHERUNGEN/FUSES
Size Standard
2 Metal Gripping-Lugs with Combi Indicator IEC 60269-2-1
Rated Voltage AC 500 V / DC 440 V Rated Voltage AC 690 V / DC 440 V
Rated Part No. Weight Pack Rated Part No. Weight Pack
Current Current
[A] [kg/1] [A] [kg/1]
35 20 004 13.35 0.28 3 35 20 212 13.35 0.48 3
40 20 004 13.40 0.28 3 40 20 212 13.40 0.48 3
50 20 004 13.50 0.28 3 50 20 212 13.50 0.48 3
63 20 004 13.63 0.28 3 63 20 212 13.63 0.48 3
80 20 004 13.80 0.28 3 80 20 212 13.80 0.48 3
100 20 004 13.100 0.28 3 100 20 212 13.100 0.48 3
125 20 004 13.125 0.28 3 125 20 212 13.125 0.48 3
160 20 004 13.160 0.28 3 160 20 212 13.160 0.48 3
200 20 004 13.200 0.48 3 200 20 212 13.200 0.48 3
224 20 004 13.224 0.48 3 224 20 212 13.224 0.65 3
250 20 004 13.250 0.48 3 250 20 212 13.250 0.65 3
300 20 004 13.300 0.65 3 300 20 212 13.300 0.65 3
315 20 004 13.315 0.65 3 315 20 212 13.315 0.65 3
355 20 004 13.355 0.65 3 355 20 212 13.355 0.65 3
400 20 004 13.400 0.65 3 400 20 212 13.400 0.65 3
Size Standard
3 Metal Gripping-Lugs with Combi Indicator IEC 60269-2-1
Rated Voltage AC 500 V / DC 400 V Rated Voltage AC 690 V / DC 400 V
Rated Part No. Weight Pack Rated Part No. Weight Pack
Current Current
[A] [kg/1] [A] [kg/1]
300 20 213 13.300 0.88 3
315 20 005 13.315 0.65 3 315 20 213 13.315 0.88 3
355 20 005 13.355 0.65 3 355 20 213 13.355 0.88 3
400 20 005 13.400 0.65 3 400 20 213 13.400 0.88 3
425 20 005 13.425 0.88 3 425 20 213 13.425 0.88 3
500 20 005 13.500 0.88 3 500 20 213 13.500* 1.27 3
630 20 005 13.630 0.88 3
* with Top indicator
NH 10 www.siba.de
SICHERUNGEN/FUSES
NH
Size Standard
4 Metal Gripping-Lugs with Top Indicator IEC 60269-2-1
Rated Voltage AC 500 V Rated Voltage AC 690 V
Rated Part No. Weight Pack Rated Part No. Weight Pack
Current Current
[A] [kg/1] [A] [kg/1]
400 20 006 13.400 2.46 1 400 20 225 13.400 2.46 1
500 20 006 13.500 2.46 1 500 20 225 13.500 2.46 1
630 20 006 13.630 2.46 1 630 20 225 13.630 2.46 1
800 20 006 13.800 2.46 1 800 20 225 13.800 2.46 1
1 000 20 006 13.1000 2.46 1
1 250 20 006 13.1250 2.46 1
1 600 20 228 13.1600 3.20 1
Size Standard
4a Metal Gripping-Lugs with Top Indicator IEC 60269-2-1
Rated Voltage AC 500 V Rated Voltage AC 690 V
Rated Part No. Weight Pack Rated Part No. Weight Pack
Current Current
[A] [kg/1] [A] [kg/1]
400 20 120 13.400 3.2 1 400 20 227 13.400 3.0 1
500 20 120 13.500 3.2 1 500 20 227 13.500 3.0 1
630 20 120 13.630 3.2 1 630 20 227 13.630 3.0 1
800 20 120 13.800 3.2 1 800 20 227 13.800 3.0 1
1 000 20 120 13.1000 3.2 1
1 250 20 120 13.1250 3.2 1
1 600 20 120 13.1600 3.2 1
www.siba.de NH 11
NH SICHERUNGEN/FUSES
A max. 2.13 ” (54 mm) A max. 2.13 ” (54 mm) A max. 2.80 ” (71.5mm) A max. 2.95 ” (75 mm) A max. 2.95 ” (75 mm)
B 0.60” (15 mm) B 0.60 ” (15 mm) B 0.60 ” (15 mm) B 0.80 ” (20 mm) B 0.80 ” (20 mm)
C 1.85 ” (47 mm) C 1.85 ” (47 mm) C 2.56 ” (65 mm) C 2.56 ” (65 mm) C 2.56 ” (65 mm)
D 0.80 ” (20.5 mm) D 1.16 ” (29.5 mm) D 1.16 ” (29.5 mm) D 1.16 ” (29.5 mm) D 1.65 ” (42 mm)
E 1.60” (40.5 mm) E 1.80 ” (46 mm) E 1.80 ” (46 mm) E 1.80 ” (46 mm) E 2.03 ” (51.5 mm)
F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm)
G 1.38 ” (35 mm) G 1.38 ” (35 mm) G 1.38 ” (35 mm) G 1.57 ” (40 mm) G 1.57 ” (40 mm)
H 2.05 ” (52 mm) H 2.28 ” (58 mm) H 2.28 ” (58 mm) H 2.28 ” (58 mm) H 2.52 ” (64 mm)
I 0.28 ” (7 mm) I 0.50 ” (13 mm) I 0.50 ” (13 mm) I 0.30 ” (8 mm) I 0.55 ” (14 mm)
L 3.07 ” (78 mm) L 3.07 ” (78 mm) L 4.92 ” (125 mm) L 5.30 ” (135 mm) L 5.30 ” (135 mm)
A max. 2.95 ” (75 mm) A max. 2.95 ” (75 mm) A max. 2.95 ” (75 mm) A max. 2.95 ” (75 mm) A max. 2.95 ” (75 mm)
B 0.80 ” (20 mm) B 0.80 ” (20 mm) B 1.02 ” (26 mm) B 1.02 ” (26 mm) B 1.26 ” (32 mm)
C 2.56 ” (65 mm) C 2.56 ” (65 mm) C 2.56 ” (65 mm) C 2.56 ” (65 mm) C 2.56 ” (65 mm)
D 1.16 ” (29.5 mm) D 1.65 ” (42 mm) D 2.10 ” (53 mm) D 2.10 ” (53 mm) D 2.56 ” (65 mm)
E 1.80 ” (46 mm) E 2.03 ” (51.5 mm) E 2.32 ” (59 mm) E 2.32 ” (59 mm) E 2.90 ” (73.5 mm)
F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm)
G 1.90 ” (48 mm) G 1.90 ” (48 mm) G 1.90 ” (48 mm) G 2.36 ” (60 mm) G 2.36 ” (60 mm)
H 2.48 ” (63 mm) H 2.83 ” (72 mm) H 2.83 ” (72 mm) H 3.27 ” (83 mm) H 3.40 ” (86 mm)
I 0.24 ” (8 mm) I 0.55 ” (14 mm) I 0.55 ” (14 mm) I 0.55 ” (14 mm) I 0.67 ” (17 mm)
L 5.90 ” (150 mm) L 5.90 ” (150 mm) L 5.90 ” (150 mm) L 5.90 ” (150 mm) L 5.90 ” (150 mm)
A max. 3.54 ” (90 mm) A 3.54 ” (100 mm) A max. 3.94 ” (100 mm)
B 1.97 ” (50 mm) B 1.97 ” (50 mm) B 1.97 ” (50 mm)
C 2.56 ” (65 mm) C 3.42 ” (87 mm) C 3.43 ” (87 mm)
D 3.94 ” (100 mm) D 3.54 ” (100 mm) D 3.94 ” (100 mm)
E 4.25 ” (108 mm) E 4.25 ” (108 mm) E 4.25 ” (108 mm)
F 0.30 ” (8 mm) F 0.30 ” (8 mm) F 0.24 ” (6 mm)
G 3.35 ” (85 mm) G 3.35 ” (85 mm) G 3.35 ” (85 mm)
H 4.84 ” (123 mm) H 4.84 ” (123 mm) H 4.84 ” (123 mm)
I 1.10 ” (28 mm) I 1.10 ” (28 mm) I 1.10 ” (28 mm)
J 0.63 ” (16 mm) J 0.63 ” (16 mm) J –
K 5.90 ” (150 mm) K 5.90 ” (150 mm) K –
L 7.87 ” (200 mm) L 7.87 ” (200 mm) L 7.87 ” (200 mm)
NH 12 www.siba.de
SICHERUNGEN/FUSES
NH
A max. 2.13 ” (54 mm) A max. 2.13 ” (54 mm) A max. 2.80 ” (71.5mm) A max. 2.95 ” (75 mm) A max. 2.95 ” (75 mm)
B 0.60 ” (15 mm) B 0.60 ” (15 mm) B 0.60 ” (15 mm) B 0.80 ” (20 mm) B 0.80 ” (20 mm)
C 1.85 ” (47 mm) C 1.85 ” (47 mm) C 2.56 ” (65 mm) C 2.56 ” (65 mm) C 2.56 ” (65 mm)
D 0.80 ” (20.5 mm) D 1.16 ” (29.5 mm) D 1.16 ” (29.5 mm) D 1.65 ” (42 mm) D 1.65 ” (42 mm)
E 1.60 ” (40.5 mm) E 1.80 ” (46 mm) E 1.80 ” (46 mm) E 2.03 ” (51.5 mm) E 2.03 ” (51.5 mm)
F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm)
G 1.38 ” (35 mm) G 1.38 ” (35 mm) G 1.38 ” (35 mm) G 1.57 ” (40 mm) G 1.90 ” (48 mm)
H 2.05 ” (52 mm) H 2.28 ” (58 mm) H 2.28 ” (58 mm) H 2.52 ” (64 mm) H 2.83 ” (72 mm)
I 0.28 ” (7 mm) I 0.50 ” (13 mm) I 0.50 ” (13 mm) I 0.55 ” (14 mm) I 0.55 ” (14 mm)
L 3.07 ” (78 mm) L 3.07 ” (78 mm) L 4.92 ” (125 mm) L 5.30 ” (135 mm) L 5.90 ” (150 mm)
A max. 2.95 ” (75 mm) A max. 2.95 ” (75 mm) A max. 2.95 ” (75 mm) A max. 2.95 ” (75 mm)
B 1.02 ” (26 mm) B 1.02 ” (26 mm) B 1.26 ” (32 mm) B 1.26 ” (32 mm)
C 2.56 ” (65 mm) C 2.56 ” (65 mm) C 2.56 ” (65 mm) C 2.56 ” (65 mm)
D 2.10 ” (53 mm) D 2.10 ” (53 mm) D 2.56 ” (65 mm) D 2.87 ” (73 mm)
E 2.32 ” (59 mm) E 2.32 ” (59 mm) E 2.90 ” (73.5 mm) E 2.87 ” (73 mm)
F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm)
G 1.90 ” (48 mm) G 2.36 ” (60 mm) G 2.36 ” (60 mm) G 2.36 ” (60 mm)
H 2.83 ” (72 mm) H 3.27 ” (83 mm) H 3.40 ” (86 mm) H 3.40 ” (86 mm)
I 0.55 ” (14 mm) I 0.55 ” (14 mm) I 0.67 ” (17 mm) I 0.63 ” (16 mm)
L 5.90 ” (150 mm) L 5.90 ” (150 mm) L 5.90 ” (150 mm) L 5.90 ” (150 mm)
20 225 13 20 227 13
www.siba.de NH 13
NH SICHERUNGEN/FUSES
Size Standard
000 Metal Insulated Gripping-Lugs with Combi Indicator IEC 60269-2-1
Rated Voltage AC 500 V Rated Voltage AC 690 V
Rated Part No. Weight Pack Rated Part No. Weight Pack
Current Current
[A] [kg/1] [A] [kg/1]
2 20 438 13.2 0.12 10 2 20 452 13.2 0.12 10
4 20 438 13.4 0.12 10 4 20 452 13.4 0.12 10
6 20 438 13.6 0.12 10 6 20 452 13.6 0.12 10
10 20 438 13.10 0.12 10 10 20 452 13.10 0.12 10
16 20 438 13.16 0.12 10 16 20 452 13.16 0.12 10
20 20 438 13.20 0.12 10 20 20 452 13.20 0.12 10
25 20 438 13.25 0.12 10 25 20 452 13.25 0.12 10
32 20 438 13.32 0.12 10 32 20 452 13.32 0.12 10
35 20 438 13.35 0.12 10 35 20 452 13.35 0.12 10
40 20 438 13.40 0.12 10 40 20 452 13.40 0.12 10
50 20 438 13.50 0.12 10 50 20 452 13.50 0.12 10
63 20 438 13.63 0.12 10
80 20 438 13.80 0.12 10
100 20 438 13.100 0.12 10
Size Standard
00 Metal Insulated Gripping-Lugs with Combi Indicator IEC 60269-2-1
Rated Voltage AC 500 V Rated Voltage AC 690 V
Rated Part No. Weight Pack Rated Part No. Weight Pack
Current Current
[A] [kg/1] [A] [kg/1]
63 20 453 13.63 0.154 10
80 20 453 13.80 0.154 10
100 20 453 13.100 0.154 10
125 20 439 13.125 0.154 10 125 20 453 13.125 0.154 10
160 20 439 13.160 0.154 10
NH 14 www.siba.de
SICHERUNGEN/FUSES
NH
Size Standard
1 Insulated Gripping-Lugs with Combi Indicator IEC 60269-2-1
Rated Voltage AC 500 V Rated Voltage AC 690 V
Rated Part No. Weight Pack Rated Part No. Weight Pack
Current Current
[A] [kg/1] [A] [kg/1]
16 20 441 13.16 0.28 3 16 20 455 13.16 0.44 3
20 20 441 13.20 0.28 3 20 20 455 13.20 0.44 3
25 20 441 13.25 0.28 3 25 20 455 13.25 0.44 3
32 20 441 13.32 0.28 3 32 20 455 13.32 0.44 3
35 20 441 13.35 0.28 3 35 20 455 13.35 0.44 3
40 20 441 13.40 0.28 3 40 20 455 13.40 0.44 3
50 20 441 13.50 0.28 3 50 20 455 13.50 0.44 3
63 20 441 13.63 0.28 3 63 20 455 13.63 0.44 3
80 20 441 13.80 0.28 3 80 20 455 13.80 0.44 3
100 20 441 13.100 0.28 3 100 20 455 13.100 0.44 3
125 20 441 13.125 0.28 3 125 20 455 13.125 0.44 3
160 20 441 13.160 0.28 3 160 20 455 13.160 0.44 3
200 20 441 13.200 0.44 3 200 20 455 13.200 0.44 3
224 20 441 13.224 0.44 3
250 20 441 13.250 0.44 3
Size Standard
2 Insulated Gripping-Lugs with Combi Indicator IEC 60269-2-1
Rated Voltage AC 500 V Rated Voltage AC 690 V
Rated Part No. Weight Pack Rated Part No. Weight Pack
Current Current
[A] [kg/1] [A] [kg/1]
35 20 442 13.35 0.28 3 35 20 456 13.35 0.48 3
40 20 442 13.40 0.28 3 40 20 456 13.40 0.48 3
50 20 442 13.50 0.28 3 50 20 456 13.50 0.48 3
63 20 442 13.63 0.28 3 63 20 456 13.63 0.48 3
80 20 442 13.80 0.28 3 80 20 456 13.80 0.48 3
100 20 442 13.100 0.28 3 100 20 456 13.100 0.48 3
125 20 442 13.125 0.28 3 125 20 456 13.125 0.48 3
160 20 442 13.160 0.28 3 160 20 456 13.160 0.48 3
200 20 442 13.200 0.48 3 200 20 456 13.200 0.48 3
224 20 442 13.224 0.48 3 224 20 456 13.224 0.65 3
250 20 442 13.250 0.48 3 250 20 456 13.250 0.65 3
300 20 442 13.300 0.65 3 300 20 456 13.300 0.65 3
315 20 442 13.315 0.65 3 315 20 456 13.315 0.65 3
355 20 442 13.355 0.65 3
400 20 442 13.400 0.65 3
www.siba.de NH 15
NH SICHERUNGEN/FUSES
NH 16 www.siba.de
SICHERUNGEN/FUSES
NH
Standard
Dimensions Metal Insulated Gripping-Lugs IEC 60269-2-1
20 438 13 20 439 13 20 441 13 20 441 13 20 442 13
≤ 160 A > 160 A ≤ 160 A
A max. 2.13 ” (54 mm) A max. 2.13 ” (54 mm) A max. 2.95 ” (75 mm) A max. 2.95 ” (75 mm) A max. 2.95 ” (75 mm)
B 0.60 ” (15 mm) B 0.60 ” (15 mm) B 0.80 ” (20 mm) B 0.80 ” (20 mm) B 0.80 ” (20 mm)
C 1.85 ” (47 mm) C 1.85 ” (47 mm) C 2.56 ” (65 mm) C 2.56 ” (65 mm) C 2.56 ” (65 mm)
D 0.80 ” (20.5 mm) D 1.16 ” (29.5 mm) D 1.16 ” (29.5 mm) D 1.65 ” (42 mm) D 1.16 ” (29.5 mm)
E 1.60 ” (40.5 mm) E 1.80 ” (46 mm) E 1.80 ” (46 mm) E 2.03 ” (51.5 mm) E 1.80 ” (46 mm)
F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm)
G 1.38 ” (35 mm) G 1.38 ” (35 mm) G 1.57 ” (40 mm) G 1.57 ” (40 mm) G 1.90 ” (48 mm)
H 2.05 ” (52 mm) H 2.28 ” (58 mm) H 2.28 ” (58 mm) H 2.52 ” (64 mm) H 2.48 ” (63 mm)
I 0.28 ” (7 mm) I 0.50 ” (13 mm) I 0.30 ” (8 mm) I 0.55 ” (14 mm) I 0.24 ” (6 mm)
L 3.07 ” (78 mm) L 3.07 ” (78 mm) L 5.30 ” (135 mm) L 5.30 ” (135 mm) L 5.90 ” (150 mm)
A max. 2.95 ” (75 mm) A max. 2.95 ” (75 mm) A max. 2.95 ” (75 mm) A max. 2.13 ” (54 mm) A max. 2.13 ” (54 mm)
B 0.80 ” (20 mm) B 1.02 ” (26 mm) B 1.26 ” (32 mm) B 0.60 ” (15 mm) B 0.60 ” (15 mm)
C 2.56 ” (65 mm) C 2.56 ” (65 mm) C 2.56 ” (65 mm) C 1.85 ” (47 mm) C 1.85 ” (47 mm)
D 1.65 ” (42 mm) D 2.10 ” (53 mm) D 2.56 ” (65 mm) D 0.80 ” (20.5 mm) D 1.16 ” (29.5 mm)
E 2.03 ” (51.5 mm) E 2.32 ” (59 mm) E 2.90 ” (73.5 mm) E 1.60 ” (40.5 mm) E 1.80 ” (46 mm)
F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm)
G 1.90 ” (48 mm) G 1.90 ” (48 mm) G 2.36 ” (60 mm) G 1.38 ” (35 mm) G 1.38 ” (35 mm)
H 2.83 ” (72 mm) H 2.83 ” (72 mm) H 3.40 ” (86 mm) H 2.05 ” (52 mm) H 2.28 ” (58 mm)
I 0.55 ” (14 mm) I 0.55 ” (14 mm) I 0.67 ” (17 mm) I 0.28 ” (7 mm) I 0.50 ” (13 mm)
L 5.90 ” (150 mm) L 5.90 ” (150 mm) L 5.90 ” (150 mm) L 3.07 ” (78 mm) L 3.07 ” (78 mm)
A max. 2.95 ” (75 mm) A max. 2.95 ” (75 mm) A max. 2.95 ” (75 mm)
B 0.80 ” (20 mm) B 0.80 ” (20 mm) B 1.02 ” (26 mm)
C 2.56 ” (65 mm) C 2.56 ” (65 mm) C 2.56 ” (65 mm)
D 1.65 ” (42 mm) D 1.65 ” (42 mm) D 2.10 ” (53 mm)
E 2.03 ” (51.5 mm) E 2.03 ” (51.5 mm) E 2.32 ” (59 mm)
F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm)
G 1.57 ” (40 mm) G 1.90 ” (48 mm) G 1.90 ” (48 mm)
H 2.52 ” (64 mm) H 2.83 ” (72 mm) H 2.83 ” (72 mm)
I 0.55 ” (14 mm) I 0.55 ” (14 mm) I 0.55 ” (14 mm)
L 5.30 ” (135 mm) L 5.90 ” (150 mm) L 5.90 ” (150 mm)
www.siba.de NH 17
NH SICHERUNGEN/FUSES
20 389 03 20 386 03
NH 18 www.siba.de
SICHERUNGEN/FUSES
NH
www.siba.de NH 19
NH SICHERUNGEN/FUSES
NH 20 www.siba.de
SICHERUNGEN/FUSES
NH
www.siba.de NH 21
NH SICHERUNGEN/FUSES
A max. 2.13 ” (54 mm) A max. 2.13 ” (54 mm) A max. 2.80 ” (71.5mm) A max. 2.95 ” (75 mm) A max. 2.95 ” (75 mm)
B 0.60 ” (15 mm) B 0.60 ” (15 mm) B 0.60 ” (15 mm) B 0.80 ” (20 mm) B 0.80 ” (20 mm)
C 1.85 ” (47 mm) C 1.85 ” (47 mm) C 2.56 ” (65 mm) C 2.56 ” (65 mm) C 2.56 ” (65 mm)
D 0.80 ” (20.5 mm) D 1.16 ” (29.5 mm) D 1.16 ” (29.5 mm) D 1.65 ” (42 mm) D 1.65 ” (42 mm)
E 1.60 ” (40.5 mm) E 1.80 ” (46 mm) E 1.80 ” (46 mm) E 2.03 ” (51.5 mm) E 2.03 ” (51.5 mm)
F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm)
G 1.38 ” (35 mm) G 1.38 ” (35 mm) G 1.38 ” (35 mm) G 1.57 ” (40 mm) G 1.90 ” (48 mm)
H 2.05 ” (52 mm) H 2.28 ” (58 mm) H 2.28 ” (58 mm) H 2.52 ” (64 mm) H 2.83 ” (72 mm)
I 0.28 ” (7 mm) I 0.50 ” (13 mm) I 0.50 ” (13 mm) I 0.55 ” (14 mm) I 0.55 ” (14 mm)
L 3.07 ” (78 mm) L 3.07 ” (78 mm) L 4.92 ” (125 mm) L 5.30 ” (135 mm) L 5.90 ” (150 mm)
A max. 2.95 ” (75 mm) A max. 2.95 ” (75 mm) A max. 2.95 ” (75 mm) A max. 2.95 ” (75 mm)
B 1.02 ” (26 mm) B 1.02 ” (26 mm) B 1.26 ” (32 mm) B 1.26 ” (32 mm)
C 2.56 ” (65 mm) C 2.56 ” (65 mm) C 2.56 ” (65 mm) C 2.56 ” (65 mm)
D 2.10 ” (53 mm) D 2.10 ” (53 mm) D 2.56 ” (65 mm) D 2.87 ” (73 mm)
E 2.32 ” (59 mm) E 2.32 ” (59 mm) E 2.90 ” (73.5 mm) E 2.87 ” (73 mm)
F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm)
G 1.90 ” (48 mm) G 2.36 ” (60 mm) G 2.36 ” (60 mm) G 2.36 ” (60 mm)
H 2.83 ” (72 mm) H 3.27 ” (83 mm) H 3.40 ” (86 mm) H 3.40 ” (86 mm)
I 0.55 ” (14 mm) I 0.55 ” (14 mm) I 0.67 ” (17 mm) I 0.63 ” (16 mm)
L 5.90 ” (150 mm) L 5.90 ” (150 mm) L 5.90 ” (150 mm) L 5.90 ” (150 mm)
20 225 08 20 227 08
NH 22 www.siba.de
SICHERUNGEN/FUSES
NH
20 386 08 20 389 08
www.siba.de NH 23
NH SICHERUNGEN/FUSES
NH 24 www.siba.de
SICHERUNGEN/FUSES
NH
20 004 15 20 005 15
≤ 577 A
20 005 15 20 120 15
> 577 A
www.siba.de NH 25
NH SICHERUNGEN/FUSES
20 246 02
NH 26 www.siba.de
Electrical Characteristics
SICHERUNGEN/FUSES
NH
Size Rated Voltage Operating Class Rated Breaking Capacity Standard
000 AC 500 V gG 120 kA IEC 60269-2-1
Rated Part No. Power Pre-arcing Total Total
Current Loss l2t-value l2t-value @ 254 V l2t-value @ 440 V
[A] [W] [A2s] [A2s] [A2s]
6 20 000 13.6 / 20 438 13.6 1.4 36 75 130
10 20 000 13.10 / 20 438 13.10 1.2 230 320 560
16 20 000 13.16 / 20 438 13.16 1.6 420 490 810
20 20 000 13.20 / 20 438 13.20 1.8 760 910 1 480
25 20 000 13.25 / 20 438 13.25 2.3 1 440 1 780 2 890
32 20 000 13.32 / 20 438 13.32 3.1 2 600 3 360 5 630
35 20 000 13.35 / 20 438 13.35 3.8 3 100 4 770 7 610
40 20 000 13.40 / 20 438 13.40 4.0 4 700 6 750 11 300
50 20 000 13.50 / 20 438 13.50 4.0 5 900 8 340 13 600
63 20 000 13.63 / 20 438 13.63 4.5 10 300 16 200 26 400
80 20 000 13.80 / 20 438 13.80 5.4 17 300 27 200 45 500
100 20 000 13.100 / 20 438 13.100 6.5 28 900 45 500 88 600
www.siba.de NH 27
NH SICHERUNGEN/FUSES
Electrical Characteristics
NH 28 www.siba.de
Electrical Characteristics
SICHERUNGEN/FUSES
NH
Size Rated Voltage Operating Class Rated Breaking Capacity Standard
4 AC 500 V gG 120 kA IEC 60269-2-1
Rated Part No. Power Pre-arcing Total Total
Current Loss l2t-value l2t-value @ 254 V l2t-value @ 440 V
[A] [W] [A2s] [A2s] [A2s]
400 20 006 13.400 26 859 000 1 236 000 2 008 000
500 20 006 13.500 38 1 130 000 1 670 000 2 800 000
630 20 006 13.630 49 1 950 000 2 980 000 4 840 000
800 20 006 13.800 66 3 700 000 5 450 000 8 900 000
1000 20 006 13.1000 78 5 800 000 8 900 000 14 400 000
1250 20 006 13.1250 95 11 000 000 16 200 000 27 200 000
1600 20 228 13.1600 138 14 000 000 20 700 000 33 600 000
www.siba.de NH 29
NH SICHERUNGEN/FUSES
Electrical Characteristics
t(s)
Cut-Off Characteristics
Ic
(kA)
Cut-off Current Peak
NH 30 www.siba.de
Electrical Characteristics
SICHERUNGEN/FUSES
NH
Size Rated Voltage Operating Class Rated Breaking Capacity Standard
000 AC 690 V gG 120 kA IEC 60269-2-1
Rated Part No. Power Pre-arcing Total Total Total
Current Loss l2t-value l2t-value @ 254 V l2t-value @ 440 V l2t-value @ 500 V
[A] [W] [A2s] [A2s] [A2s] [A2s]
16 20 477 13.16 / 20 452 13.16 1.9 420 490 810 920
20 20 477 13.20 / 20 452 13.20 2.35 760 910 1 480 1 670
25 20 477 13.25 / 20 452 13.25 2.75 1 440 1 780 2 890 3 270
32 20 477 13.32 / 20 452 13.32 3.6 2 600 3 360 5 630 6 360
35 20 477 13.35 / 20 452 13.35 4 3 100 4 770 7 610 8 600
40 20 477 13.40 / 20 452 13.40 4.4 4 700 6 750 11 300 12 800
50 20 477 13.50 / 20 452 13.50 5 5 900 8 340 13 600 15 300
www.siba.de NH 31
NH SICHERUNGEN/FUSES
Electrical Characteristics
NH 32 www.siba.de
Electrical Characteristics
SICHERUNGEN/FUSES
NH
Size Rated Voltage Operating Class Rated Breaking Capacity Standard
4 AC 690 V gG 120 kA IEC 60269-2-1
Rated Part No. Power Pre-arcing Total Total Total
Current Loss l2t-value l2t-value @ 254 V l2t-value @ 440 V l2t-value @ 500 V
[A] [W] [A2s] [A2s] [A2s] [A2s]
400 20 225 13.400 32 859 000 1 236 000 2 008 000 2 558 000
500 20 225 13.500 42 1 113 000 1 670 000 2 800 000 3 360 000
630 20 225 13.630 51 1 950 000 2 980 000 4 840 000 6 000 000
800 20 225 13.800 65 3 700 000 5 450 000 8 900 000 11 300 000
www.siba.de NH 33
NH SICHERUNGEN/FUSES
Electrical Characteristics
t(s)
Cut-Off Characteristics
Ic
(kA)
Cut-off Current Peak
NH 34 www.siba.de
Electrical Characteristics
SICHERUNGEN/FUSES
NH
Size Rated Voltage Operating Class Rated Breaking Capacity
000 AC 1000 V gB 25 kA
Rated Part No. Pre-arcing Total
Current l2t-value l2t-value @ 760 V
[A] [A2s] [A2s]
6 20 386 03.6 6 18
10 20 386 03.10 31 93
16 20 386 03.16 83 250
20 20 386 03.20 145 435
25 20 386 03.25 210 630
35 20 386 03.35 440 1 320
50 20 386 03.50 870 2 610
63 20 386 03.63 1 350 4 050
80 20 386 03.80 2 300 6 900
100 20 386 03.100 3 300 9 900
www.siba.de NH 35
NH SICHERUNGEN/FUSES
Electrical Characteristics
t(s)
Cut-Off Characteristics
Ic
(kA)
Cut-off Current Peak
NH 36 www.siba.de
Electrical Characteristics
SICHERUNGEN/FUSES
NH
Size Rated Voltage Operating Class Rated Breaking Capacity Standard
000 AC 690 V aM 120 kA IEC 60269-2
Rated Part No. Power Pre-arcing Total Total Total
Current Loss l2t-value l2t-value @ 254 V l2t-value @ 440 V l2t-value @ 500 V
[A] [W] [A2s] [A2s] [A2s] [A2s]
16 20 477 08.16 0.8 476 780 950 1 280
20 20 477 08.20 1.0 921 1 500 1 850 2 500
25 20 477 08.25 1.4 1 441 2 400 2 880 3 900
35 20 477 08.35 1.8 2 820 4 700 5 640 7 600
50 20 477 08.50 2.4 7 290 12 000 14 600 19 700
www.siba.de NH 37
NH SICHERUNGEN/FUSES
Electrical Characteristics
NH 38 www.siba.de
Electrical Characteristics
SICHERUNGEN/FUSES
NH
Size Rated Voltage Operating Class Rated Breaking Capacity Standard
4 AC 690 V aM 120 kA IEC 60269-2
Rated Part No. Power Pre-arcing Total Total Total
Current Loss l2t-value l2t-value @ 254 V l2t-value @ 440 V l2t-value @ 500 V
[A] [W] [A2s] [A2s] [A2s] [A2s]
400 20 225 08.400 31 623 000 1 030 000 1 246 000 1 680 000
500 20 225 08.500 40 829 000 1 370 000 1 658 000 2 240 000
630 20 225 08.630 48 1 470 000 2 245 000 2 940 000 3 970 000
800 20 225 08.800 58 2 780 000 4 590 000 5 560 000 7 510 000
1000 20 225 08.1000 71 4 510 000 7 460 000 9 020 000 12 200 000
www.siba.de NH 39
NH SICHERUNGEN/FUSES
Electrical Characteristics
t(s)
Cut-Off Characteristics
Ic
(kA)
Cut-off Current Peak
NH 40 www.siba.de
Electrical Characteristics
SICHERUNGEN/FUSES
NH
Size Rated Voltage Operating Class Rated Breaking Capacity Standard
000 AC 1000 V aM 25 kA IEC 60269-2
Rated Part No. Pre-arcing Total
Current l2t-value l2t-value @ 760 V
[A] [A2s] [A2s]
16 20 386 08.16 520 2 100
20 20 386 08.20 930 3 700
25 20 386 08.25 1 450 5 800
35 20 386 08.35 2 450 9 800
50 20 386 08.50 5 500 22 000
63 20 386 08.63 10 500 42 000
80 20 386 08.80 13 000 52 000
100 20 386 08.100 19 000 76 000
t(s) Ic
(kA)
Virtual Pre-arcing Time
www.siba.de NH 41
NH SICHERUNGEN/FUSES
Electrical Characteristics
NH 42 www.siba.de
Electrical Characteristics SICHERUNGEN/FUSES
NH
Time-Current Characteristics Rated Voltage AC 400 V Operating Class gTr
t(s)
Cut-Off Characteristics
Ic
(kA)
Cut-off Current Peak
www.siba.de NH 43
NH SICHERUNGEN/FUSES
t(s) Ic
(kA)
Virtual Pre-arcing Time
NH 44 www.siba.de
SICHERUNGEN/FUSES
NH
Sizes Rated Voltage Standard
Knife-Links 00 - 4a AC 690 V DIN 43620
B 0.60 ” (15 mm) B 0.60 ” (15 mm) B 0.80 ” (20 mm) B 0.60 ” (15 mm) B 1.02 ” (26 mm)
C 1.90 ” (48 mm) C 2.56 ” (65 mm) C 2.56 ” (65 mm) C 1.90 ” (48 mm) C 2.56 ” (65 mm)
F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm) F 0.24 ” (6 mm)
G 1.38 ” (35 mm) G 1.46 ” (37 mm) G 1.65 ” (42 mm) G 1.38 ” (35 mm) G 2.13 ” (54 mm)
J – J – J – J – J –
K – K – K – K – K –
L 3.07 ” (78 mm) L 4.92 ” (125 mm) L 5.30 ” (135 mm) L 3.07 ” (78 mm) L 5.90 ” (150 mm)
1 Insulated Gripping-Lugs
Size 4 Size 4a
Part No. Part No.
24 006 02 24 006 07
www.siba.de NH 45
NH SICHERUNGEN/FUSES
Part No.
21 001 01
A 3.94 ” (100 mm)
B 0.80 ” (20 mm)
C 1.26 ” (32 mm)
D 3.90 ” (99 mm)
E 1.32 ” (33.5 mm)
F 1.14 ” (29 mm)
G 2.32 ” (59 mm)
H 3.40 ” (86 mm)
I 2.24 ” (57 mm)
J 4.72 ” (120 mm)
L 5.30 ” (135 mm)
M M8
N 0.98 ” (25 mm)
O 0.30 ” (7.5 mm)
Size Standard
External Wall 000 + 00 DIN 43620
Part No.
25 001 01
F 3.15 ” (80 mm)
H 3.40 ” (86 mm)
L 5.30 ” (135 mm)
Size Standard
Partition Wall 000 + 00 DIN 43620
Part No.
25 001 03-2
H 3.15 ” (80 mm)
L 5.30 ” (135 mm)
NH 46 www.siba.de
SICHERUNGEN/FUSES
NH
Size Rated Voltage Standard
Fuse-Bases 3 pole 000 + 00 AC 690 V DIN 43620
Rated Current Part No. Weight Pack
[A] [kg/1]
160 21 001 03 0.81 1
Part No.
21 001 03
A 3.94 ” (100 mm)
B 0.80 ” (20 mm)
C 1.26 ” (32 mm)
D 3.90 ” (99 mm)
E 1.32 ” (33.5 mm)
F 1.14 ” (29 mm)
G 2.32 ” (59 mm)
H 3.40 ” (86 mm)
I 2.24 ” (57 mm)
J 4.72 ” (120 mm)
L 5.30 ” (135 mm)
M M8
N 0.98 ” (25 mm)
O 0.30 ” (7.5 mm)
Size Standard
External Wall 000 + 00 DIN 43620
Part No.
25 001 01
F 3.15 ” (80 mm)
H 3.40 ” (86 mm)
L 5.30 ” (135 mm)
www.siba.de NH 47
NH SICHERUNGEN/FUSES
Part No.
21 002 04
A 5.98 ” (152 mm)
B 0.79 ” (20 mm)
C 1.26 ” (32 mm)
D 1.14 ” (29 mm)
G 2.32 ” (59 mm)
I 2.87 ” (73 mm)
J 5.35 ” (136 mm)
L 6.81 ” (173 mm)
M M8
N 0.98 ” (25 mm)
O 0.30 ” (7.5 mm)
Size Standard
External Wall 0 DIN 43620
Part No.
25 002 01
F 4.16 ” (106 mm)
H 4.52 ” (115 mm)
L 7.85 ” (200 mm)
NH 48 www.siba.de
SICHERUNGEN/FUSES
NH
Size Rated Voltage Standard
Fuse-Bases 1 pole 1-3 AC 690 V DIN 43620
Rated Current Part No. Weight Pack
[A] [kg/1]
250 21 003 01 0.72 1
400 21 004 01 0.88 1
630 21 005 01 1.16 1
Size Standard
External Wall 1-3 DIN 43620
Size
Contact Insulating Covers for NH Fuse-Base 1-3
Size Part No. for Weight Pack
Fuse-Base [kg/1]
1 21 003 01.26 21 003 01 0.020 10
2 21 004 01.26 21 004 01 0.025 10
3 21 005 01.26 21 005 01 0.030 10
www.siba.de NH 49
NH SICHERUNGEN/FUSES
Size 1 Size 2
Part No. Part No.
21 003 03 21 004 03
A 6.90 ” (175 mm) A 7.87 ” (200 mm)
B 1.30 ” (33 mm) B 1.30 ” (33 mm)
C 1.97 ” (50 mm) C 1.97 ” (50 mm)
D 6.54 ” (166 mm) D 7.00 ” (178 mm)
E 2.52 ” (64 mm) E 2.68 ” (68 mm)
F 1.38 ” (35 mm) F 1.38 ” (35 mm)
G 3.30 ” (84 mm) G 3.58 ” (91 mm)
H 4.20 ” (107 mm) H 4.72 ” (120 mm)
L 7.87 ” (200 mm) L 9.06 ” (230 mm)
M M 10 M M 10
O 0.40 ” (10 mm) O 0.40 ” (10 mm)
P 0.65 ” (16.5 mm) P 0.65 ” (16.5 mm)
V 0.40 ” (10 mm) V 0.40 ” (10 mm)
Size Standard
External Wall 1+2 DIN 43620
Size 1 Size 2
Part No. Part No.
25 003 01 25 004 01
H 4.20 ” (107 mm) H 4.72 ” (120 mm)
L 7.87 ” (200 mm) L 9.06 ” (230 mm)
NH 50 www.siba.de
SICHERUNGEN/FUSES
NH
Size Rated Voltage Standard
Fuse-Bases with Binding Screw Contacts 4 AC 690 V DIN 43620
Rated Current Part No. Weight Pack
[A] [kg/1]
1250 21 006 01 3.65 1
1600 21 006 05 3.65 1
www.siba.de NH 51
NH SICHERUNGEN/FUSES
Part No.
21 031 01
A 10.50 ” (267 mm)
B 1.30 ” (33 mm)
C 2.17 ” (55 mm)
F 1.46 ” (37 mm)
G 3.86 ” (98 mm)
I 5.40 ” (137 mm)
J 8.07 ” (205 mm)
L 11.65 ” (296 mm)
M M 12
N 1.18 ” (30 mm)
O 0.40 ” (10.5 mm)
P 0.65 ” (16.5 mm)
NH 52 www.siba.de
SICHERUNGEN/FUSES
NH
Size Rated Voltage
Grip-Handle 00 - 3 500 - 690 V
Grip Handle Part No. Weight Pack
[kg/1]
Standard 22 001 02 0.24 1
Protected by Leather Glove 22 001 05 0.63 1
www.siba.de NH 53
NH SICHERUNGEN/FUSES
Rated Voltage
GL-Switch for Gripping Lug AC 250 V – DC 30 / 24 V
Part No. Breaking Capacity Breaking Capacity Terminal
Non Inductive Load Inductive Load (L/R = 10 ms) IEC 760
[A] [A]
28 002 02 3 3 AMP 2,8 x 0,5
(Red hammer)
NH 54 www.siba.de