Professional Documents
Culture Documents
MODEL MT5011E/BMT5011E
MEDIUM DUTY DOOR OPERATOR
ith
Now lwt in
Bui ceiver
a d i o Re
R
I N TENDED F O R P R O F ES
INTENDED E SSI
S I O NA L Radio Receiver
Built on Board
IINSTALLATI
N STALLA TIO
ON OONNLL Y
Visit www.LiftMaster.com to locate a professional installing dealer in your area.
2 YEAR WARRANTY
315MHz
Serial #
NOT FOR RESIDENTIAL USE
(located on electrical box)
Installation Date
SAFETY INFORMATION
IMPORTANT NOTES:
WARNING
WARNING WARNING
• BEFORE attempting to install, operate or maintain the operator,
Mechanical you must read and fully understand this manual and follow all
safety instructions.
CAUTION
WARNING WARNING
• DO NOT attempt repair or service of your commercial door and
Electrical gate operator unless you are an Authorized Service Technician.
When you see these Safety Symbols and Signal Words on the
following pages, they will alert you to the possibility of serious
injury or death if you do not comply with the warnings that
accompany them. The hazard may come from something
WARNING
mechanical or from electric shock. Read the warnings carefully.
WARNING
CAUTION WARNING
When you see this Signal Word on the following pages, it will
alert you to the possibility of damage to your door and/or the
AVERTISSEMENT
AVERTISSEMENT
door operator if you do not comply with the cautionary AVERTISSEMENT
statements that accompany it. Read them carefully.
ATTENTION
AVERTISSEMENT AVERTISSEMENT
2
APPLICATION
INTRODUCTION
This Medium Duty Commercial Door Operator includes a number of features that will provide years of reliable and safe operation.
Features:
• Supports both monitored and non-monitored safety devices: Safety devices detect obstructions in the door's path and
automatically reverse a closing door. Safety devices are highly recommended by the manufacturer.
• Radio receiver: A factory installed radio receiver allows remote controls, keyless entries and other remote command devices to be
programmed to the operator.
• Timer To Close: The Timer To Close feature allows the door to automatically close after a preset time (only available with B2
wiring and a monitored safety device).
• Wiring Types: The functionality of the operator is based on the wiring type. The operator is shipped from the factory in standard
C2 wiring type (factory default). Some wiring types will require an optional safety device. Refer to Basic Programming Section for
descriptions of wiring types, requirements and programming.
24 ga.
STANDARD SECTIONAL
20 ga. 16 ga.
--- 22 ga.
Steel Steel
---
Steel
Aluminum Wood
Fiberglass --- ---
Doors Doors
310 260 225 150 100 NOTE: Actual track length will exceed door height by 2'.
3
OPERATOR DIMENSIONS
WEIGHTS AND DIMENSIONS
HANGING WEIGHT:80-110 LBS. (36.29-49.9 kg) (Including Track)
12-1/2"
(31.75 cm)
4"
(10.16 cm)
9-1/2"
(24.13 cm)
Path Of Highest Point On
Door
16-3/16"
(41.12 cm)
OPERATOR SPECIFICATIONS
MOTOR ELECTRICAL
TYPE: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Limited duty OPERATOR VOLTAGE: . . . . . . . . . 115 Vac, Single Phase, 60 Hz
HORSEPOWER: . . . . . . . . . . . . . . . . . . . . . . . . 1/2 Horsepower WIRING TYPE: . . . . . . . C2 Standard B2 configurable (see Basic
VOLTAGE: . . . . . . . . . . . . . . . . . . . . 115Vac, Single Phase, 60Hz Programming section)
FULL LOAD AMPS:. . . . . . . . . . . . . . . . . . . . . . . . . . . 6.0 Amps CONTROL WIRING: . . . . . . . . . . . . . . . . . . . . . . . . . .16-22 AWG
MECHANICAL SAFETY
DOOR SPEED:. . . . . . . . . . . . . . . . . . . . 12" (30.48 cm) / second DISCONNECT . . . . . . . . . . . . . . . . . . Quick disconnect door arm
OUTPUT FORCE:. . . . . . . . . . . . . . . . . . . . . . . . . 125 ft. lbs/ sec. for emergency manual door operation.
BRAKE (BMT ONLY): . . . . . . . . . . Solenoid actuated disc brake ENTRAPMENT PROTECTION: . . . . Supports both monitored and
LIMIT ADJUST:. . . . . .Fully adjustable up to 14' door maximum non-monitored safety devices including LiftMaster CPS
DUTY: . . . . . . . . . . . . . . . . . . . . . .12 Cycles per hour maximum photo-eyes and industry standard sensing edges.
50 Cycles per day maximum
BEARINGS: . . . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance Free
FINISH: . . . . . . . . . . . Powder coated, Corrosion Resistant Steel
ENVIRONMENTAL
LOCATION: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Indoor, dry location
OPERATING TEMPERATURE: . . . . . . . . . . . . . . . -4˚ F to +122˚F (-20C˚ to + 50˚C)
4
CARTON INVENTORY
Before beginning your installation check that all components
were provided. ITEM DESCRIPTION QTY
1 Operator 1
2 Track (left & right)
15 Door height plus 2' 2
1 3 Track Spacers 2
4 Front Idler 1
5 Trolley 1
6 Take-up Bolt 1
7 Chain 1
^
OP
EN
8 Master Links 2
14 ^
CLOS
O
STOP
E
9 Header Bracket 1
10 Header Pivot Shaft 1
11 Curved Door Arm 1
8 4 12 Straight Arm 1
13 Door Bracket 1
10 14 3-Button Station 1
9 15 Warning Sign 2
NOT SHOWN
Installation Manual 1
Quickstart Guide 1
3 User’s Guide 1
7
Caution Label 1
Installation Hardware Bag 1
Complete with: Bolts 3/8"-16 x 3/4 " (10),
6 Flanged Hex Nuts 3/8"-16 (14), Bolt 3/8"-16 x 1
13 (3), Lockwashers 3/8" (3), Cotter Pins (2) and
2 Carriage Bolts (2)
11 NOTE: Depending on door height, the quantity of track
12
5 spacers and hardware may vary.
PREPARATION
PREPARING YOUR DOOR
WARNING
The manufacturer recommends 3' (91.4 cm) of clearance around
the operator for serviceability. Before you begin: To prevent possible SERIOUS INJURY or DEATH:
• DO NOT connect electric power until instructed to do so.
• Disable locks. CAUTION
• If the door lock needs to remain functional, install an
• Remove any ropes connected to door.
interlock switch.
• Before the operator is installed, be sure the door has been
properly aligned and is working smoothly. Although each • ALWAYS call a trained professional door serviceman if door
binds, sticks or is out of balance. An unbalanced door may
installation will vary due to particular building characteristics,
not reverse when required.
refer to the following general procedures to install the operator.
• NEVER try to loosen, move or adjust doors, door springs,
cables, pulleys, brackets or their hardware, ALL of which are
under extreme tension and can cause SERIOUS personal
INJURY.
• Disable ALL locks and remove ALL ropes connected to door
BEFORE installing and operating door operator to avoid
entanglement.
AVERTISSEMENT
5
ASSEMBLY
Header End
1 Install track spacers
Flange
Position the track spacers evenly Hex Nut
over the length of the track using Bolt
the pre-punched holes. For doors Track 3/8" - 16 x 3/4"
up to 12' use 2 track spacers, for Spacers
14' doors use 3 spacers.
Track
Bolt
3/8" - 16 x 3/4"
Flange
Hex Nut
Operator End
Front Idler
Header End
Trolley
Take-Up Bolt
Track
6
ASSEMBLY
4 Slide trolley onto the track
Track
Track Operator End
Trolley
Trolley
Operator
End
Bolt
3/8" - 16 x 3/4"
Bolt
3/8" - 16 x 3/4"
Flange Hex
Operator Nut
End
Bolt
3/8" - 16 x 3/4"
Bolt
3/8" - 16 x 3/4"
Operator
7
ASSEMBLY
6 Install chain
Attach chain
to front of Wrap chain
trolley Chain Track around front
idler
Front Idler
Trolley
Master Link
Chain
Run chain around
track in the direction
indicated Slide trolley 2" away from front idler
2"
Wrap chain
around drive
Attach chain
sprocket
to back of
trolley
Adjust the
chain by
tightening the
inner nut
Operator
Trolley
Drive
Sprocket Inner Nut
Chain
Master Link
Bottom of Bottom of
More
Track 3" Track
than 3"
Chain
Chain
8
TYPICAL INSTALLATION
DETERMINE HEADER BRACKET MOUNTING LOCATION
The trolley operator is generally mounted over the center of the door. However, off center
mounting may be required due to interfering structures or location of door stile / top section
support. Typically, the operator may be mounted up to 24" (60.96 cm) off center on torsion
spring doors. Extension springs require center mounting.
Level (Optional)
Header Wall
Level
High Point of
Door Travel
9
T Y P I C A L I N S T A L L A T I O N WARNING
Highest Point
of Door Travel
4 ATTENTION
Secure header bracket
Swing the operator to a horizontal position and temporarily NOTE: Secure the header bracket to the
secure with rope, chain or support from floor. Make sure that header using the appropriate method.
the operator is aligned with the header bracket.
ADVERTENCIA
Torsion
PRECAUCIÓN
Spring
Track
Temporary
Support
Cotter Pin
Header
Pivot Shaft
10
T Y P I C A L I N S T A L L A T I O N WARNING
Lock Nut
Washer
Bolt
(Not Provided)
AVERTISSEMENT
Bolt
Nut (Not Provided)
Bolt
(Not Provided)
ATTENTION
Lock
Washer
Nut
Lock
Washer
Straight Door
Arm Vertical
Center line
ADVERTENCIA
of Door
Bolt
3/8-16 x 3/4
Vertical
Flange
ECITO
N
Door Arm PRECAUCIÓN
Hex Nut
Bolt Door
3/8-16 x 3/4
Lock
Nut
Curved
Door Bracket Door
Door Arm
Bracket
11
NG WARNING
TYPICAL INSTALLATION
N WARNING
To reduce the risk of SEVERE INJURY or DEATH: • ALL electrical connections MUST be made by a qualified
• ANY maintenance to the operator or in the area near the individual.
operator MUST NOT be performed until disconnecting the • DO NOT install ANY wiring or attempt to run the operator
electrical power and locking-out the power via the operator without consulting the wiring diagram.
power switch. Upon completion of maintenance the area • Reversing devices are recommended for ALL installations.
MUST be cleared and secured, at that time the unit may be • ALL power wiring should be on a dedicated circuit and well
returned to service. protected. The location of the power disconnect should be
• Disconnect power at the fuse box BEFORE proceeding. visible and clearly labeled.
Operator MUST be properly grounded and connected in • ALL power and control wiring MUST be run in separate
accordance with local electrical codes. The operator should be conduit.
on a separate fused line of adequate capacity.
EMENT AVERTISSEMENT
POWER AND GROUND WIRING CONNECTIONS POWER WIRING CHART
NOTE: Power and control wiring must be run in separate conduit
DISTANCE GAUGE
in accordance with local electrical codes. Must use 14 AWG or
ON AVERTISSEMENT
50'
heavier wire for power wiring. Use conduit knockouts for wiring as 14 AWG
indicated on the electrical box labels. 100' 12 AWG
200' 8 AWG*
IMPORTANT NOTE: Operator must be properly grounded. Failure 350' 6 AWG*
to properly ground the operator could result in electric shock and 500' 4 AWG*
serious injury. 1000' 2 AWG*
* Maximum wire gauge that can be connected to the
8 Remove cover operator’s terminal is 12 AWG. When a larger wire gauge
is required, the wire must be gauged down to 12 AWG.
NCIA ADVERTENCIA
ÓN ADVERTENCIA
Conduit
Power
Ground
Neutral
Hot
Control
Do NOT turn power on until you have finished making ALL power and control wiring connections.
12
T Y P I C A L I N S T A L L A T I O N WARNING
11 Install 3-button control station
CAUTION
To prevent possible SEVERE INJURY or DEATH, install
Select location for 3-button control station reversing sensors when:
• The radio is used.
• The 3-button control station is out of sight of the door.
• Or ANY other control (automatic or manual) is used.
Remove
cover
Reversing devices are recommended for ALL installations.
^
OP
EN
Screws ^
CL
OS
E
O
ST
OP
Select appropriate knockout and
run wire according to local
electrical code from operator to
3-button control station.
Wall
Secure using AVERTISSEMENT
appropriate
hardware
ATTENTION
5' (1.5 m) 3-Button
Control Station
^
OP
EN
^
CL
OS
E
O
STO
P
Power
Wire 3-button control
station
^
OP
EN
^
CL Knockout
OS
E
O
ST
OP
^^^^
AUX
AUX ANT ANT
AUX ANT
1 2 3 4 5 6 7
R27
ADVERTENCIA
TTC LEARN STOP CLOSE OPEN
D14
LED
Remove
factory jumper
if external
1 2 3 4 5 6 7 PRECAUCIÓN
Warning
sign
interlock is
used
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN
Stop
Close
Open
3-Button
Control Station
^
^
OPEN
Warning
sign
CLOSE
Common
O
STOP
13
TYPICAL INSTALLATION
Standoff
Antenna
Antenna
Retaining Plate
Increase
OPEN Limit Nut Door Travel
OPEN Limit Switch Decrease
CLOSE Limit Nut Door Travel
SAFETY
Limit Switch
NOTE: When retaining plate is released, verify that the retaining plate is fully seated with the notches of the limit nut.
14
ADJUSTMENT
A B
To
Loosen
Bend
ends of
cotterpin
to secure
clutch
nut
Clutch Nut Clutch Nut
To
Tighten
SENSING EDGES
When properly connected, the sensing edge will make contact
with an obstruction while the door is closing, the door will stop
and typically reverse to the full open position.
The sensing edge must be installed on the bottom of the door.
15
OPTIONAL SAFETY DEVICE CONFIGURATIONS
X ANT
ANT
CPS Photo-Eyes
TTC
^^^^
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN
LED
2
(White)
D14
LEARN
(White/Black)
3
4
STOP
5
NOTE: When installing model CPS-LN4, connect the brown wire to
CLOSE OPEN
terminal 1 and the blue wire to terminal 2.
6
7
AUX ANT
CPS Photo-Eyes with 2-wire sensing edge
AUX ANT
2-wire electric or pneumatic sensing edge
TTC
^^^^
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN
LED
2
(White)
D14
LEARN
(White/Black)
3
4
STOP
5
CLOSE OPEN
6
7
(White)
^^^^
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN
LED
2
D14
LEARN
3
4
STOP
5
CLOSE OPEN
6
7
AUX ANT
AUX ANT
(White)
LED
2
D14
LEARN
3
4
STOP
5
CLOSE OPEN
6
7
16
LOGIC BOARD LAYOUT
4 3 2 1
6 ^^^^
AUX
AUX ANT ANT
1 2 3 4 5 6 7
8 9
10
17
BASIC PROGRAMMING
WARNING
DETERMINE THE WIRING TYPE
The functionality of this operator is based on the wiring type. The
CAUTION
operator is shipped from the factory in standard C2 wiring type
(factory default). Some wiring types will require an optional To prevent possible SEVERE INJURY or DEATH, install
reversing sensors when:
safety device. Refer to the following descriptions of wiring types,
requirements and programming. • The radio is used.
• The 3-button control station is out of sight of the door.
NOTE: 1. The LED on the logic board will blink once when in C2 • Or ANY other control (automatic or manual) is used.
and twice when in B2.
Reversing devices are recommended for ALL installations.
2. The operator will automatically convert to B2 wiring
(option D) when Monitored Safety Device is installed. If
the Monitored Safety Device is removed, the operator
will go into a Restricted Close mode**. Turn power
OFF and ON to reset wiring type.
** Restricted close mode requires a constant pressure close
command. The operator will begin closing after a 5 second AVERTISSEMENT
delay and will continue to close to the close limit switch. The
operator will stop if the pressure to close is released before
reaching the close limit.
ATTENTION
C2 WIRING TYPE WITHOUT MONITORED SAFETY DEVICE C2 WIRING TYPE WITH MONITORED SAFETY DEVICE
A (Factory Default) B
• Momentary contact to open and stop with constant • Momentary contact to open and stop with constant
pressure to close. pressure to close.
• Open override that reverses when closing by any opening • Open override that reverses when closing by any opening
device. device.
• Wiring for safety device to reverse. NOTE: The operator • Wiring for safety device to reverse. NOTE: The operator
will automatically convert to B2 wiring (option D) when will automatically convert to B2 wiring (option D) when
Monitored Safety Device is installed. (See accessories Monitored Safety Device is installed. (See accessories
page for Monitored Safety Devices) page for Monitored Safety Devices)
• Timer to Close (TTC) feature not available. • Timer to Close (TTC) feature not available.
NON-MONITORED SAFETY DEVICE MONITORED SAFETY DEVICE
ADVERTENCIA
PRECAUCIÓN
Sensing Edge
Photo Eye
D7 D5
U4 D6 D4
J4
014A1030 C32
C20
TP1 R25
C9
C31
U1
C21
J2 R27
D14
K2
D7 D5
TTC LEARN STOP CLOSE OPEN LT
U4 D6 D4
J4 LED C29
014A1030 R24
D14
1 2 3 4 5 6 7
C32 P1
C20
LED
TP1 R25
C9
C31
U1
C21
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN
D9
L5
J2 R27
D14
K2
TTC LEARN STOP CLOSE OPEN LT
LED C29
1 2 3 4 5 6 7 R24
D14
P1
D9
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN
LED
1 2 3 4 5 6 7
1 2 3 4 5 6 7
18
BASIC PROGRAMMING
B2 WIRING TYPE WITHOUT MONITORED SAFETY DEVICE B2 WIRING TYPE WITH MONITORED SAFETY DEVICE
C Requires a non-monitored safety device.
D
• Momentary contact to open, close and stop. • Momentary contact to open, close and stop.
• Open override that reverses when closing by any opening • Open override that reverses when closing by any opening
device. device.
• Wiring for safety device to reverse. NOTE: The operator • Wiring for safety device to reverse. NOTE: The operator
will automatically convert to B2 wiring (option D) when will automatically convert to B2 wiring when Monitored
Monitored Safety Device is installed. (See accessories Safety Device is installed. (See accessories page for
page for Monitored Safety Devices) Monitored Safety Devices)
• Timer to Close (TTC) feature not available. • Timer to Close (TTC) feature available.
D7 D5
U4 D6 D4
J4
014A1030 C32
C20
TP1 R25
C9
C31
U1
C21
J2 R27
D14
K2
TTC LEARN STOP CLOSE OPEN LT
LED C29
D14
1 2 3 4 5 6 7 R24
P1
D9
LMEP1 LMEP2 COM INTRLK STOP CLOSE OPEN
LED
1 2 3 4 5 6 7
19
BASIC PROGRAMMING
REMOTE CONTROLS TIMER TO CLOSE (TTC)
SINGLE BUTTON REMOTE CONTROL Timer to Close feature enables the operator to close from the
Built in 315 MHz radio receiver permits as many as 20 open limit after a preset time, adjustable from 5 to 60 seconds.
Security✚® remote controls or dip switch remote controls in any Requires LiftMaster monitored safety device.
combination. TO PROGRAM
TO PROGRAM 1. Begin with door in fully closed position.
1. Press and release the LEARN button (LED will light). 2. Press and release the LEARN button (LED will light).
2. Press and hold the button on the remote control until the 3. Press and release the TTC button.
LED flashes rapidly, then release to complete programming 4. Every press and release of the STOP button will add 5 seconds
(LED will go out). to the Timer to Close. Example: 30 second TTC = 6 presses of
3. Repeat steps 1 and 2 for additional remote controls. the STOP button.
Electrical Box Logic Board 5. Press and release the TTC button to exit programming mode.
6. The LED will flash once per 5 seconds of timer setting.
LEARN STOP CLOSE OPEN
The TTC will become active after completion of the next open
D14
LED
cycle.
C9
TP1
C20
014A1030
J4
C32
R25
D7
U4 D6
D5
D4
U1
C21
L5
^^^^
AUX
AUX ANT
ANT
C18
J2 R27
D14
K2
1 2 3 4 5 OPEN 6 7
TO VERIFY TIMER TO CLOSE (TTC) SETTING
TTC LEARN STOP CLOSE OPEN LT
LED C29
1 2 3 4 5 6 7 R24
P1
Open
D4
J4
U1
C21
L5
1 2 3 4 5
Close
^^^^
AUX
AUX ANT
ANT
C18
J2 R27
Stop
LED C29
1 2 3 4 5 6 7 R24
P1
3. Press and hold the desired button of the remote control until
LED flashes rapidly, then release.
4. Repeat steps 1 through 3 to program additional buttons. CLEAR THE TIMER TO CLOSE (TTC)
1. Press and release the LEARN button (LED will light.)
TO ERASE ALL REMOTE CONTROLS
2. Press and hold the TTC button for 6 seconds.
Press and hold the LEARN button (over 5 seconds) until the
LED goes out. All programmed remote controls will be erased. 3. Release the TTC button (LED will go out).
The TTC will no longer be active.
Electrical Box Logic Board
TIMER DEFEAT
The TTC can be temporarily disabled by pressing a STOP button.
D14
LEARN STOP CLOSE OPEN
TTC will become enabled after the next open command.
LED
D7 D5
U4 D6 D4
J4
014A1030 C32
C20
TP1 R25
C9
C31
U1
C21
L5
^^^^
AUX
AUX ANT
ANT
C18
J2 R27
1 2 3 4 5 6 7
RADIO OPERATION
D14
K2
TTC LEARN STOP CLOSE OPEN LT
LED C29
1 2 3 4 5 6 7 R24
P1
20
WARNING TESTING
WARNING
Turn on power, LED will flash 7 times on power up. Test all
CAUTION
controls and safety devices to make sure they are working WARNING
properly. It may be necessary to refer back to the Adjustment
section for adjustment of the limits. To avoid SERIOUS PERSONAL INJURY or DEATH from
IMPORTANT NOTES: electrocution, disconnect ALL electric power BEFORE
performing ANY maintenance.
• Do not leave power to the operator on unless all safety and
entrapment protection devices have been tested and are
working properly. TEST THE SAFETY DEVICES (IF INSTALLED)
• Be sure you have read and understand all safety instructions 1. Open the door.
included in this manual. 2. Place an obstruction in the path of the photo eyes or sensing
• Be sure the owner or person(s) responsible for operation of the edge.
door have read and understand the safety instructions, know 3. Press the CLOSE button.
how to electrically operate the door in a safe manner and how The door should not close if photo eyes are installed. The door
to manually disconnect the door from the operator. should close to obstruction and reverse if sensing edge is
AVERTISSEMENT
TEST 3-BUTTON CONTROL STATION installed. AVERTISSEMENT
1. Press OPEN button. (The door should move in the open 4. Remove the obstruction.
direction.) 5. Press CLOSE button. Door should close.
ATTENTION
2. Press STOP button. (The door should stop.)
3. Press CLOSE button. (The door should move in the close
AVERTISSEMENT
If door did not reverse from obstruction, check safety devices.
WARNING
MANUAL DISCONNECT
ADVERTENCIA ADVERTENCIA
CAUTION
PRECAUCIÓN door or arm:
ADVERTENCIA
To prevent possible SERIOUS INJURY or DEATH from a falling
Emergency • DO NOT stand under the door arm when pulling the
Disconnect emergency release.
• If possible, use emergency release handle to disengage trolley
ONLY when door is CLOSED. Weak or broken springs or
unbalanced door could result in an open door falling rapidly
and/or unexpectedly.
• NEVER use emergency release handle unless doorway is clear
of persons and obstructions.
22
TROUBLESHOOTING
The status of the operator can be determined by counting the number of flashes of the LED on the logic board.
DIAGRAM
Green
L2
Blue* Black
L1
Capacitor
Yellow
Red
Yellow
Red
OPEN
Motor CLOSE
CLOSE OPEN
STOP
Brown**
6
5
STOP
Purple
3
Yellow
LED
Safety
TTC
Limit
Switch
ANT
J2
AUX
ANT
Open Close
Limit Limit
Switch Switch
Grey
23
REPAIR PARTS
ELECTRICAL BOX
4 K2
K3
K4
2
K1
1
K5
24
REPAIR PARTS
2
K6
3 4
21
20
K1
5
K3
14 7
14
6 K5
15
17 16
9 10
11
15
14
12
14 6
18
8
K4
K2
13
K1
19
25
REPAIR PARTS
26
OPEN
OPEN
ACCESSORIES
REMOTE CONTROLS 315MHz ENTRAPMENT PROTECTION DEVICES
371LM ®
1-Button SECURITY✚ Remote Control: Monitored PRESS
TO
® R ING
Includes visor clip. CPS-LN4 Commercial Protector System :
OPEN
Provides protection on doors up
to 45' wide. NEMA-4 rated.
OPEN
CONTROL STATIONS
WIRE
02-102 2-Button Control Station:
65-7WIREL 7 Conductor 20 AWG Wire (500'):
Steel enclosure.
Recommended for control wiring.
OPEN
CLOSE
CLOSE
OPEN
27
PRESS
CONTROL CONNECTION DIAGRAM
IMPORTANT NOTES:
1. The 3-Button Control Station provided must be connected for operation.
2. If a STOP button is not used, a jumper must be placed between terminals 3 and 5.
3. If INTERLOCK is not used a jumper must be placed between terminals 3 and 4.
4. When adding accessories, install them one at a time and test each one after it is added to ensure proper installation and operation
with the Commercial Door Operator.
3 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON
STANDARD 2 OR MORE KEY LOCKOUT
7 6 3 5
7 6 3 5 7 6 3 5
Open
Open
Open Open
Close
Close
Close Close Stop
Stop
Stop Stop
Keyswitch
C2 C2
MODE ONLY MODE ONLY
Open Open Open
Sensing Device
ONE 2 OR MORE
All Wiring Types