You are on page 1of 4

The Scully Groundhog™ ELECTRONIC

PRODUCT
Vehicle Static Grounding System LINE

Featuring Dynacheck® – Automatic and Continuous Self-Checking Circuitry

DESCRIPTION

Don't let unsure grounding methods The system consists of a rack mounted
leave you guessing. Transport vehicles control housing with two installation
should be properly tied to ground before methods. It can operate in conjunction
and during the loading operation. There with your existing Scully Overfill
should never be any doubt that the Prevention System or as an independent
grounding systems at your terminals unit. Scully Signal Company has over 30
are performing their proper function. years of electronic liquid handling system
Many systems give you little assurance of experience along with the dependability,
their operation. The Scully Groundhog™ service and safety Scully is known for.
gives you complete assurance that a
The Scully Groundhog™ grounding
proper ground tie-in is present. The
system can be used for a wide variety
Groundhog™ is a self-proving grounding
of loading applications for use with tank
system for maximum safety in loading
trucks, rail cars, and aircraft refuelers.
operations.
Groundhog™
Ground Verification System

F E AT U R E S A N D B E N E F I T S
ONLY THE SCULLY GROUNDHOG™ OFFERS YOU ALL OF THESE ADVANTAGES:

 Self-Proving, the Groundhog™  Direct grounding tie point at gantry


monitors the grounding connection available.

 Immediately shuts down the loading


throughout the loading operation.

 Can be used in conjunction with your operation if proper grounding is not


Scully Overfill Prevention System present.

 CENELEC, FM, CSA approved


offering one quick connection for
overfill protection and grounding
models available.
verification.
 No manual checks are needed.
 Can also be used as a completely
independent grounding system  Direct grounding tie point at gantry
with a special quick-release plug for available.
grounding connection to a specially
designed, vehicle mounted, electronic
ball.

60733 Rev D


Scully Signal Company 70 Industrial Way Wilmington MA 01887-3479 USA ISO 9001
www.scully.com  sales@scully.com  phone: 617 692 8600  toll-free phone: 800 2 SCULLY(728559)  fax: 617 692 8620 registered
Scully Groundhog™ Vehicle Static Grounding System

T H E S C U L LY G R O U N D H O G ™ P R O V E S I T !

The Scully Groundhog™ gives you The Groundhog™ control monitor is


complete assurance that grounding to the mounted at the gantry. Indicator lights
vehicle's frame has been accomplished*. on the face of the control monitor are
The Groundhog™ is an intelligent system visual proof that proper grounding has
which continuously and automatically been accomplished.
monitors the grounding connection during
The Groundhog™ requires that each
the entire loading operation.
vehicle is equipped with a specially
The Groundhog™ is designed to designed Scully electronic ground ball
immediately shut down the loading or bolt. Before the loading operation
operation if the ground tie-in is broken. can begin, the controller must see an
That’s proof-positive, something no other intelligent return signal from the ground
system can provide. ball or bolt, indicating that a proper
Scully Ground Bolt grounding connection has been made.

ARE YOUR GROUNDING SYSTEM OPTIONS LIMITED?


AS PART OF YOUR SCULLY OVERFILL PREVENTION SYSTEM:

The Groundhog™ Control Unit can be Prevention Plug and Cable together with
wired into your existing Scully Overfill a special Scully Ground Bolt mounted
Prevention System for the ultimate safety on each vehicle. The Scully Ground Bolt’s
system. Just one connection gives you sensing lead is wired to the Scully Overfill
overfill and grounding protection. This Prevention Socket.
single connection simplifies loading and
Only Scully offers you a complete,
eliminates the need for additional plugs
integrated overfill prevention and vehicle
One Connection for Overfill and cables at the gantry.
grounding system for maximum safety in
Prevention and Grounding
The Groundhog™ utilizes a spare your loading operations.
conductor in the existing Scully Overfill

O R D E R I N G I N F O R M AT I O N
If you intend to wire the Groundhog™ in conjunction with your existing Scully Overfill Prevention System, you need only
order the control monitor. For the independent system, order the control monitor and junction box with plug and cable.

C O N T R O L U N I T S A N D P L U G & C A B L E A S S E M B LY
Model Description Part #
ST-47-115 EL Control monitor with lamps (115 VAC operation) 08508
ST-47-115 ELK Control monitor with lamps and key protected bypass switch (115 VAC operation) 08220
ST-47-115 ELK/D Control monitor with lamps, key protected bypass switch with additional circuitry
for deadman switch 08749
ST-47-240 EL Control monitor with lamps (240 VAC operation) 08675
ST-47-240 ELK Control monitor with lamps and key protected bypass switch (240 VAC operation) 08502
SC-47 Rack mounted heavy duty junction box with 20' straight cable and ground proving
plug for connection to vehicle mounted ground proving ball (Independent System) 08249
SC-47CC Rack mounted heavy duty junction box with 32' coiled cable and ground proving plug
for connection to vehicle mounted ground proving ball (Independent System) 08567
SC-47CC/D Same as SC-47-CC with additional circuitry for the deadman switch for aviation applications 08653


Scully Signal Company 70 Industrial Way Wilmington MA 01887-3479 USA ISO 9001
www.scully.com  sales@scully.com  phone: 617 692 8600  toll-free phone: 800 2 SCULLY(728559)  fax: 617 692 8620 registered
Scully Groundhog™ Vehicle Static Grounding System

D O N ’ T U S E A S Y S T E M T H AT I S E A S I LY C H E AT E D .
There are many systems that claim to that unless the proper grounding
be foolproof and even self-checking. It is connection has been made, the loading
possible with many of these systems to process will not begin. It will automatically
bypass a safe ground tie-in by attaching shut down the loading operation if the
the clamp to the rack, a metal shim or by ground is broken. The Groundhog’s™
jumping the plug contacts with a paper intelligent monitoring capabilities and the
clip. In many cases, there is no proof that special electronic circuitry inside the
proper grounding has been made or the Scully Ground Ball and Ground Bolt form
system is functioning correctly. a self-proving system. No manual checks
are needed.
The Scully Groundhog™ foils these
typical cheating methods and mal- Only the Scully Groundhog™ can provide
functioning problems that can lead you with the safest and most dependable
to grounding vehicles improperly. means for vehicle static grounding. It
maintains the integrity of your loading
The Scully Grounding System insures
operation.

S C U L LY H A S A S Y S T E M F O R E V E R Y A P P L I C AT I O N !
AS A SEPARATE AND INDEPENDENT GROUNDING SYSTEM:

The Groundhog™ can be used as a a specially designed electronic Scully


completely independent system. Ground Ball mounted on each vehicle.
This system is ideal for top loading The controller in conjunction with the
or applications where a Scully Overfill ground ball provides and verifies vehicle
Prevention System is not in use. grounding before loading can begin.
The controller must receive an electronic
The control monitor connects to a heavy
return signal from the ball throughout the
Scully Groundhog™ Control duty Sculcon® junction box with attached
loading operation.
Monitor with Plug and Cable cable and special quick release snap-on
and Ground Ball™ plug. The Scully Ground Plug connects to

R E P L A C E M E N T PA R T S

Model Description Part #


Ground Ball™ Truck mounted electronic ground proving ball for independent Grounding System 08274
Ground Bolt™ Truck mounted electronic ground proving bolt for wiring to overfill prevention socket 08560
Coiled Cable Replacement plug and 32' coiled cable assembly for SC-47 08566
Straight Cable Replacement plug and 20' straight cable assembly for SC-47 08219
Plug Replacement plug only for SC-47 08565
Module 115 Replacement module for 115 VAC models 22040
Bulb 135V Replacement indicator lamp bulb for 115 VAC models 27005
Module 240 Replacement module for 240 VAC models 22407
Bulb, 250V Replacement indicator lamp bulb for 240 VAC models 27006
Deadman Control Deadman switch with coiled cable 08863


Scully Signal Company 70 Industrial Way Wilmington MA 01887-3479 USA ISO 9001
www.scully.com  sales@scully.com  phone: 617 692 8600  toll-free phone: 800 2 SCULLY(728559)  fax: 617 692 8620 registered
Vehicle Static Grounding System Specifications

M20 x 1.5 All Dimensions in Inches


(Millimeters in Parenthesis) 27 mm (1.06" Hole for
50.8 Conduit Hub (Cable Gland)
(2.0)
CL

31.3 mm
43.2 43.2 (3.20")
(1.7) (1.7)

Top View Mounting Centers for


36.6 mm
#8 (4 mm) Hex Socket
Mtg. (1.44")
Head Screws (4 Places)
Lug 146 100.0 mm
Ctr. (5.75) 27 mm (1.06")
(3.94")
Knockout for 65.5 mm
Conduit Hub (2.58")
(Cable Gland)

12.7
100.0 mm 186.2 mm
(.50)
(3.94") (7.33")
347.7
(13.62) 200.0 mm
171.5
(7.87")
(6.75)

Back View
scully

214.3
(8.37)

Front View

31.8
(1.25) M20 x 1.5

CL

50.8
(2.0)
171.5
(6.75) 169.3
(6.62)
Bottom View
42.6 Side View
(1.68)

Model ST-47C ELK Shown in Illustration Model SC-47 CC Shown in Illustration*


*Dimensions of units manufactured prior to 3/1/97 may vary.

T E C H N I C A L S P E C I F I C AT I O N S
Operation Temp.: -40° to +60° C (-40° to +140° F). Output Control: One normally open user contact
Enclosure: Explosion-Proof/Weather-Proof rated 250, 5A
IP65 suffix “E”. Power Requirements:
Indicators: Red: Not Grounded/Non-Permit. ST-47C-240 Models: 208-240 VAC, 50/60 Hz.
Green: Grounded/Permit. 0.125 Amperes maximum.
Response Time: 0.5 Seconds Maximum. ST-47C-120 Models: 105-125 VAC, 50/60 Hz.
Electrical Connections: Internal terminal strips, 0.250 Amperes maximum.
identified for easy installation. Shipping Weights: ST-47C-ELK; 12 kgs (26 lbs)
Bypass Switch: Key lockable off-on bypass switch ST-47C-EL; 12 kgs (26 lbs)
for ELK model only. SC-47; 4 kgs (9 lbs)

The explosion-proof housing is approved for mounting in Class I, Division 1, Groups C & D environments by FM Global (FM) and the Canadian
Standards Association (CSA). The intrinsically safe outputs are approved for use in Class I, Division 1, Groups A, B, C & D environments by FM and CSA.

The Scully Groundhog™, when used in conjunction with an overfill prevention controller and connected to a vehicle mounted Ground Bolt™ via the
overfill prevention system's plug and cable, is protected under U.S. Patent No. 4,901,195.
Copyright © 2008 Scully Signal Company. Biclops, Dynacheck, Dynamic Self-Checking, Dynamic Self-Test, Faylsafe, IntelliCheck, Intellitrol, Intelliview, Load Anywhere,
Maxsafety, MulteCept, Sculcon, Scully, Scultrol, Scul-Lock,Scul-Tel, Scul-Tite, TABS and V.I.P. are registered trademarks of Scully Signal Company. All Rights Reserved.
Specifications are subject to change without notice.

Scully Signal Company Scully UK Ltd.


70 Industrial Way, email: sales@scullyuk.com
Wilmington, MA 01887-3479, USA website: www.scully.com
tel: (800) 272 8559
(617) 692 8600 Scully Systems Europe NV
fax: (617) 692 8620 email: info@scully.be 60733 Rev D
website: www.scully.com © Scully Signal Company
email: sales@scully.com May 2008
website: www.scully.com

You might also like