SPLIT MAGNETIC INDUCTION

WATER HEATER
BY

HARVER

INSTRUCTION MANUAL
CN50LH-2kw + 2kw
CN75LH-2kw + 2kw
Thank you for purchasing and using our product.

Please read this instruction manual carefully before


using the unit and keep this manual for future
reference

CONTENTS

PRODUCT INFORMATION-----------------------------PAGE 2

SAFETY PRECAUTIONS---------------------------------PAGE 3

INSTALLATION PRECAUTIONS----------------------PAGE 4

TROUBLE SHOOTING CODES-------------------------PAGE 5

TECHNICAL SPECIFICATIONS-------------------------PAGE 5

HEATING TIMES-----------------------------------------PAGE 5

INSTALLATION INSTRUCTIONS----------------------PAGE 6/7

Page1
1. PRODUCT INFORMATION

This product has been developed from Western Harver


Technology and also using new temperature sensing technology.
These units are tested to CE specification and l local SANS &
NRCS requirements have been installed and passed.
The unit is split into two parts, the storage tank and the
generator unit.
The process of heating the water uses magnetic induction, which
heats the water more rapidly than conventional water heaters.
The electrical supply to the generator is converted into a
magnetic energy that then causes a resistance field which in
turn heats the water. This means that there is no direct electrical
a/c current in close proximity to the water, making it safer.
The unit uses new temperature sensing technology that is more
accurate. There is a high density thermal insulation layer, to
sustain the water temperature.
All these processes increase the efficiency and therefore save
electricity.
There are several protection systems in place such as: dry burn,
over heat, low/ high voltage, surge and over heat protection.

PLEASE NOTE – THIS UNIT IS NOT AN INSTANTANEOUS WATER


HEATER

Page 2
SAFETY PRECAUTIONS
Please ensure the amp rating of the socket is rated above that of
the unit.
To avoid damage and chance of electric shock, please do not wet
the generator unit.
Do not put any metal object into the exhaust duct of the
generator unit to avoid electric shock.
If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified person
in order to prevent a hazard.
Do not block the air intake or exhaust vent of the generator unit.
Allow 150mm free space around generator intake/exhaust ports
Do not place objects that are affected by magnetism such as
watches, radios, televisions, bank cards etc .near the unit.
Persons with pacemakers, please consult your doctor before
using.
It is recommended to remove the drain plug to remove the dirty
water annually
Place unit out of reach of children and make sure children are
supervised in the use of the hot water.
People that are mentally challenged or physically handicapped
must be supervised in the operation of this unit.
If there any defects or malfunction that are not able to be fixed
by switching the unit off and then on – please contact after sales
service. Water may drip from the discharge pipe of the
expansion control valve and that this pipe must be left open to
the atmosphere. Discharge pipes connected to the expansion
control valve and the TP valve are to be of metal and installed in
a continuously downward direction, in a frost-free ambient with
the outlet being left open to the atmosphere.
DO NOT attempt to repair the unit yourself.
Page 3
3.

DO NOT ATTEMPT TO INSTALL THE UNIT AS PER THE PICTURES BELOW

THE UNT WILL NOT OPERATE CORRECTLY AND WILL CAUSE A DRY
BURN ERROR

THE WARRANTY WILL BE NULL AND VOID

Page 4
5. TROUBLE SHOOTING CODES.

E0 No power output.

E1 Input voltage low (less than 90 volts a/c)

E2 Input voltage high (above 270 volts a/c)

E4 Electronics temperature too high

E5 No water in heater (dry burn)

E6 Unable to read temperature output

6. TECHNICAL SPECIFICATIONS

Unit 50 Litre 75 Litre


Power supply 230V 50Hz 230V 50Hz
Rated Power 2000w+2000w 2000w+2000w
Rated Current 9 amp + 9 amp 9amp + 9 amp
Water
pressure 600 kpa 600 kpa
Waterproof
Level IPX4 IPX4
Dimensions mm 1180 x 440 x 240 1550 x 440 x 240

7. HEATING TIMES

Time to heat water per 1 deg.


Unit 50 Litre 75 Litre
2KW 1.3 min
4KW 0.7 min 0.9 min

Page 5
1 2 3
INSTALLATION DIAGRAM CN50L

DRILL TWO HOLES INTO WALL


FIT SUPPLIED RAWL HOOKS
HANG MAIN UNIT ON HOOKS
NOTE: UNIT IS A HORIZONTAL FIT GENERATOR UNIT ON FIT GENERATOR UNIT ON
WALL MOUNTED LEFT SIDE OF UNIT. RIGHT SIDE OF UNIT.
PLUMB UNIT INTO WATER PLUG INTO WALL SOCKET PLUG INTO WALL SOCKET
SUPPLY AS PER PLUMBING CONTROLS WILL FACE TO NOTE: UNIT WITH SPEC
DIAGRAM REAR LABEL IS RIGHT SIDE
FILL UNIT WITH WATER NOTE: LEFT UNIT MASTER UNIT.
BEFORE APPLYING CONTROLLED BY RIGHT DOUBLE SOCKET WITH
ELECTRICAL POWER TO UNIT UNIT. NO NEED TO PRESS 25AMP CB and 2.5mm
ENSURE ALL AIR IS OUT OF THE POWER BUTTON TO BE USED
UNIT BY OPENING HOT
WATER OUTLET TO ALLOW ALLOW 150MM FREE ALLOW 150MM FREE SPACE
AIR TO ESCAPE SPACE AROUND AROUND INTAKE/EXHAUST
NOTE:
INTAKE/EXHAUST DUCTS DUCTS
COLD WATER SUPPLY SHOULD COME FROM ABOVE UNIT TO PREVENT
4 5 6
UNCONTROLLED DRAINAGE
1) THIS UNIT MUST BE INSTALLED AS PER THE DIAGRAM
2) THIS IS A WALL MOUNTED UNIT (HORIZONTAL ONLY)
3) NOTE: IT CANNOT BE POSITIONED UPRIGHT OR LAID DOWN ON A SHELF OR THE
FLOOR
4) ENSURE THE T\P VALVE IS 600 kpa AND IS PLUMBED TO THE DRAIN OR ATOMSHPERE
IN A SAFE AREA
5) A THERMOSTATIC TEMPERING VALVE SHOULD BE USED IF THE TEMPERATURE IS SET
ABOVE 65 DEG. UNIT WILL HEAT TO 75° C
SWITCH ON AT WALL PLUGS WAIT 2 MIN - UNIT WILL
6) THE MULTI VALVE MUST BE AN APPROVED MAKE AND A 400 KPA VALVE IS TO ADJUST TEMP SETTING
INDICATOR LIGHT ON RIGHT SWITCH ON
RECOMMENDED PRESS TEMP BUTTON –
UNIT WILL FLASH (RECOMMENDED)
7) ENSURE THE ELECTRICAL SUPPLY IS CAPABLE OF 22 AMPS WITH 2+2 KW UNITS (Min TEMP SETTING WILL SHOW.
ONE BEEP WILL SOUND OR
PRESS TO CHANGE TEMP
2.5mm² cable) 38 WILL APPEAR ON DISPLAY PRESS POWER BUTTON
SETTING BY 5 DEG FROM
8) DO NOT REMOVE 15 AMP PLUG – WARRANTY IS AFFECTED ON RIGHT SIDE & WATER ONCE UNIT WILL START
40-75 DEG
9) DRIP TRAY REQUIRED IF INSTALLED IN ROOF OR CUPBOARD TEMP AFTER 5 SECONDS 75 SHOWS ON DIGITAL
10) ALLOW 150mm OPEN AREA ON GENERATOR FAN DUCTS READOUT FOR 5 SEC
IF FITTED IN A CUPBOARD DIMENSIONS MUST BE: TEMP SHOWS AFTER 5 SEC
50LH– 170(W)x100(H)x40(D) cm
75LH– 190(W)x100(H)x40(D) cm