You are on page 1of 110

ZTE Low Level Design for MSAG Upgrade Project

ZTE Low Level Design MSAG


Upgrade Project

All Rights reserved, No Spreading abroad without Permission of ZTE 1


ZTE Low Level Design for MSAG Upgrade Project

TABLE OF CONTENTS
Records of Change...................................................................................................................................................7

1 Background...........................................................................................................................................................9

2 MSAG Upgrade Project topology......................................................................................................................11

2.1 C300M Logical Topology........................................................................................................................11

2.2 MSAG 5200 Upgrade Topology..............................................................................................................11

2.3 NM Server Topology...............................................................................................................................13

2.4 Traffic flow modules...............................................................................................................................13

2.4.1 General traffic module of HSI services........................................................................................14

2.4.2 Broadband traffic between different BRAS.................................................................................15

2.4.3 General traffic module of VoIP service........................................................................................15

2.4.4 Link protection diagram...............................................................................................................16

2.5 42 MSAG physical topology introduction..............................................................................................18

3 Hardware and Software Infrastructure Design...................................................................................................63

3.1 Hardware Infrastructure Design..............................................................................................................63

3.1.1 C300M Hardware Infrastructure Design......................................................................................63

3.2 Software Infrastructure Design................................................................................................................71

3.2.1 C300M Software Infrastructure Design.......................................................................................71

4 Cabinet List and Dimensioning..........................................................................................................................74

4.1 EC40CE Outdoor Cabinet (C300M).......................................................................................................74

5 Network Reliability.............................................................................................................................................76

5.1 C300M Equipment protection.................................................................................................................76

5.2 C300M Link Aggregation protection......................................................................................................76

5.3 C300M MSTP protection........................................................................................................................78

All Rights reserved, No Spreading abroad without Permission of ZTE 2


ZTE Low Level Design for MSAG Upgrade Project

6 NMS U31 Solution.............................................................................................................................................80

6.1 Overview..................................................................................................................................................80

6.2 System Characteristics.............................................................................................................................81

6.3 Solution Introduction...............................................................................................................................81

6.4 Software Deployment..............................................................................................................................82

7 Service Deployment............................................................................................................................................84

7.1 VOIP Service...........................................................................................................................................84

7.2 Broadband Service...................................................................................................................................85

7.3 GPON Service.........................................................................................................................................86

8 DATA planning...................................................................................................................................................87

8.1 Detail IP,VLAN and port planning..........................................................................................................87

8.2 Equipment & interface naming convention.............................................................................................96

8.3 Configuration script.................................................................................................................................97

8.3.1 C300M(Enhanced MSAG 306 as sample)...................................................................................97

8.3.2 5200 V3(Old MSAG-306 as sample)...........................................................................................98

9 Power Solution..................................................................................................................................................103

9.1 Overview................................................................................................................................................103

9.2 Power System Design of MSAG Upgrade Solution.............................................................................104

9.3 Rectifier unit..........................................................................................................................................106

9.4 The high loop performance battery.......................................................................................................107

9.5 Central Monitoring System(iENERGY)...............................................................................................107

10 Acronyms........................................................................................................................................................109

All Rights reserved, No Spreading abroad without Permission of ZTE 3


ZTE Low Level Design for MSAG Upgrade Project

Figures & Tables


Figure 2-1 C300M Logical Topology...................................................................................................................11

Figure 2-2 Old MSAG 5200 Control Boards Upgrade........................................................................................12

Figure 2-3 Old MSAG 5200 Uplink Optimization..............................................................................................12

Figure 2-4 NM server Topology...........................................................................................................................13

Figure 2-5 General traffic module of HSI services.............................................................................................14

Figure 2-6 Broadband traffic between different BRAS.......................................................................................15

Figure 2-7 General traffic module of VoIP service..............................................................................................15

Figure 2-8 Link protection diagram in MSAG ring.............................................................................................16

Figure 2-9 Ring 01 of New MSAG Topology......................................................................................................20

Figure 2-10 Ring 02 of New MSAG topology.....................................................................................................24

Figure 2-11 Ring 03 of New MSAG topology.....................................................................................................28

Figure 2-12 Ring 04 of New MSAG topology.....................................................................................................33

Figure 2-13 Ring 05 of New MSAG topology.....................................................................................................36

Figure 2-14 Ring 06 of New MSAG topology.....................................................................................................40

Figure 2-15 Ring 07 of New MSAG topology.....................................................................................................42

Figure 2-16 Ring 08 of New MSAG topology.....................................................................................................46

Figure 2-17 Ring 09 of New MSAG topology.....................................................................................................49

Figure 2-18 Ring 10 of New MSAG topology.....................................................................................................51

Figure 2-19 Ring 11 of New MSAG topology.....................................................................................................53

Figure 2-20 Ring 12 of New MSAG topology.....................................................................................................56

Figure 2-21 Ring 13 of New MSAG topology.....................................................................................................58

Figure 2-22 Ring 14 of New MSAG topology.....................................................................................................60

All Rights reserved, No Spreading abroad without Permission of ZTE 4


ZTE Low Level Design for MSAG Upgrade Project

Figure 3-1 ZXA10 C300M working principle.....................................................................................................63

Figure 3-2 Appearance of ZXA10 C300M IEC 19” Service Shelf.....................................................................64

Figure 3-3 Layout of ZXA10 C300M IEC 19” Service Shelf.............................................................................65

Figure 3-4 ZXA10 C300M inner physical connection.........................................................................................67

Figure 3-5 Then connection between master shelf and slave shelf......................................................................67

Figure 3-6 Software Architecture.........................................................................................................................71

Figure 4-1 EC40CE Cabinet.................................................................................................................................74

Figure 4-2 Cable Inlet Holes at the EC40CE Cabinet Bottom.............................................................................74

Figure 4-3 EC40CE Cabinet Structure.................................................................................................................75

Figure 5-1 Link Aggregation Protection Mode ...................................................................................................76

Figure 6-1 NMS U31 System Architecture..........................................................................................................80

Figure 6-2 HA – Remote Disaster Recovery System Architecture......................................................................81

Figure 7-1 VOIP service traffic module...............................................................................................................84

Figure 7-2 Broadband service traffic module.......................................................................................................85

Figure 7-3 GPON service traffic module.............................................................................................................86

Figure 9-1 The upgraded Power solution for enhanced MSAG........................................................................105

Figure 9-2 the high efficiency rectifier unit ......................................................................................................106

Figure 9-3 the high efficiency 3KW Power unit................................................................................................106

Figure 9-4 ZXDC12 HL170Ah Battery.............................................................................................................107

Table 2-1 Phase I site list......................................................................................................................................18

Table 2-2 Aggregation Port allocation for Ring 1................................................................................................20

Table 2-3 Ring 01 MSTP design(Instance 2).......................................................................................................21

Table 2-4 Ring 01 MSTP design(Instance 3).......................................................................................................23

Table 2-5 Aggregation Port allocation for Ring 2................................................................................................24

Table 2-6 Ring 02 MSTP design(instance 2)........................................................................................................25

All Rights reserved, No Spreading abroad without Permission of ZTE 5


ZTE Low Level Design for MSAG Upgrade Project

Table 2-7 Ring 02 MSTP design(instance 3).......................................................................................................27

Table 2-8 Aggregation Port allocation for Ring 3................................................................................................29

Table 2-9 Ring 03 MSTP design(Instance 2)...............................................................................................30

Table 2-10 Ring 03 MSTP design(Instance 3).............................................................................................32

Table 2-11 Aggregation Port allocation for Ring 4..............................................................................................33

Table 2-12 Ring 04 MSTP design(Instance 4)..................................................................................................34

Table 2-13 Ring 04 MSTP design(Instance 5)..................................................................................................35

Table 2-14 Aggregation Port allocation for Ring 5..............................................................................................37

Table 2-15 Ring 05 MSTP design(Instance 4)..................................................................................................38

Table 2-16 Ring 05 MSTP design(Instance 5)..................................................................................................39

Table 2-17 Aggregation Port allocation for Ring 6..............................................................................................40

Table 2-18 Ring 06 MSTP design(Instance 2)..................................................................................................41

Table 2-19 Ring 06 MSTP design(Instance 3)..................................................................................................41

Table 2-20 Aggregation Port allocation for Ring 7..............................................................................................42

Table 2-21 Ring 07 MSTP design(Instance 4)..................................................................................................43

Table 2-22 Ring 07 MSTP design(Instance 5)..................................................................................................45

Table 2-23 Aggregation Port allocation for Ring 8..............................................................................................46

Table 2-24 Ring 08 MSTP design(Instance 6)..................................................................................................47

Table 2-25 Ring 08 MSTP design(Instance 7)..................................................................................................48

Table 2-26 Aggregation Port allocation for Ring 9..............................................................................................50

Table 2-27 Ring 09 MSTP design(Instance 2)..................................................................................................50

Table 2-28 Ring 09 MSTP design(Instance 3)..................................................................................................51

Table 2-29 Aggregation Port allocation for Ring 10............................................................................................52

Table 2-30 Ring 10 MSTP design(Instance 2)..................................................................................................52

Table 2-31 Ring 10 MSTP design(Instance 3)..................................................................................................53

Table 2-32 Aggregation Port allocation for Ring 11............................................................................................54

All Rights reserved, No Spreading abroad without Permission of ZTE 6


ZTE Low Level Design for MSAG Upgrade Project

Table 2-33 Ring 11 MSTP design(Instance 4)..................................................................................................55

Table 2-34 Ring 11 MSTP design(Instance 5)..................................................................................................56

Table 2-35 Aggregation Port allocation for Ring 12............................................................................................57

Table 2-36 Ring 12 MSTP design(Instance 8)..................................................................................................57

Table 2-37 Ring 12 MSTP design(Instance 9).................................................................................................58

Table 2-38 Aggregation Port allocation for Ring 13............................................................................................59

Table 2-39 Ring 13 MSTP design(Instance 6)..................................................................................................59

Table 2-40 Ring 13 MSTP design(Instance 7)..................................................................................................60

Table 2-41 Aggregation Port allocation for Ring 14............................................................................................61

Table 2-42 Ring 14 MSTP design(Instance 4)..................................................................................................62

Table 2-43 Ring 14 MSTP design(Instance 5)..................................................................................................62

Table 3-1 IEC 19-inch Shelf Configuration.........................................................................................................66

Table 3-2 Card list in ET Phase 4 Project.............................................................................................................68

Table 3-3 Sites detail information........................................................................................................................70

Table 3-4 Subsystem Description of the Software Architecture..........................................................................71

Table 4-1 Dimensions of ZTE EC40CE Cabinet.................................................................................................74

Table 6-1 Software Deployment for Remote 1+1 Redundant System (Server-based) .......................................82

Table 8-1 EMS Port planning...............................................................................................................................87

Table 8-2 EMS IP address/Vlan planning............................................................................................................87

Table 8-3 iENERGY IP address/Port planning....................................................................................................88

Table 8-4 MSAG uplink CS devices port planning..............................................................................................88

Table 8-5 Detail IP Address and VLAN Assignment of C300M.........................................................................90

Table 8-6 Detail VLAN Assignment of Old MSAG 5200...................................................................................94

Table 10-1 Acronyms...........................................................................................................................................109

All Rights reserved, No Spreading abroad without Permission of ZTE 7


ZTE Low Level Design for MSAG Upgrade Project

Records of Change

Version Date Author Remarks

V1.0 14-11-19 Guo HongBo First released

Modified Table of IP/VLAN


V1.1 25-11-19 GuoHongBo Design,add LACP
confguration

Updated contents as ET’s


V1.2 28-11-19 GuoHongBo
comments

V1.3 10-12-19 GuoHongBo Replaced template

V1.4 12-12-19 GuoHongBo Added new ring information

Divided to 10 sites and 32


V1.5 17-12-19 GuoHongBo
sites as two different batch

Updated documentation
V1.6 18-12-19 GuoHongBo
template

Added switch port and


V1.7 27-12-19 GuoHongBo
SVLAN of MSAG 5200

Updated contents as ET’s


V1.8 30-12-19 GuoHongBo
comments

Updated IP/VLAN/MSTP
V1.9 15-01-20 GuoHongBo planning, added iENERGY
contents

All Rights reserved, No Spreading abroad without Permission of ZTE 8


ZTE Low Level Design for MSAG Upgrade Project

1 Background
In the existing MSAG network of Ethio Telecom, most of the AA Zones (819+ MSAGs) and regional main
towns (more than 61 towns having 1110 + MSAGs) are covered by MSAG giving to more than 640K
POTs (voice), 640K ADSL and 40K Combo services (voice + data). There are also around 1543 Ethernet
passive optical network (EPON) cards (fiber connection) all over the country.

The MSAGs have been serving for 10 years and the MSAGs will be challenged to fulfill the subscribers’
requirements in the coming future. Hence, it time to plan and take prompt move to upgrade these access
equipment

The decline of the data package tariff has contributed a lot in subscribers increasing and higher
bandwidth demand. The existing MSAG covers most of the major area in a large scale and is close
to the major broadband subscribers in the country, if Ethio Telecom continues to use the
geographical advantage of MSAG to access broadband users, it will greatly save investment in
passive optical network. However, after 10 years’ operation, there are some challenges in the
existing MSAG network.

To provide higher bandwidth, advanced access technology should be deployed in the MSAG
network, such as VDSL vectoring and GPON. Moreover, the EPON card that is used to provide high
speed data/internet services with fiber cable has already been stopped manufacturing. And the
widely deployed MSAGs don’t support GPON and VDSL vectoring. So the existing MSAG network
needs to upgrade to meet the higher bandwidth demand.

Because of the rectifier system, battery, and MSAG integrated design, the battery space has the
same temperature with MSAG. But there is only one heat-exchanger for the whole cabinet. And the
aged heat-exchanger and rectifier system result in low efficiency. The heat generated from different
cards is found to shorten the life time of the battery systems. Due to the above mentioned
temperature issue and aging, the batteries backup time is reduced to 10-30 minutes. The MSAGs
require better solution to improve the power system performance.

All Rights reserved, No Spreading abroad without Permission of ZTE 9


ZTE Low Level Design for MSAG Upgrade Project

The architecture of existing MSAGs which are connected in link or ring topologies using CWDM
system is complicated, resulting in low efficiency for maintenance and high OPEX. Besides, lack of
spares is a big challenge in the CWDM network. So the CWDM needs to be removed.

This LLD offer the direction of 42 MSAG sites deployment. For example, MSAG work principle,
topology information, data plan. The LLD document will be used as a primary reference for
deployment and to some extent for the operation and maintenance.

Figure 1-1 Typical existing MSAG network

The architecture of existing MSAGs which are connected in link or ring topologies using CWDM
system is complicated, resulting in low efficiency for maintenance and high OPEX. Besides, lack of
spares is a big challenge in the CWDM network. So the CWDM needs to be removed

All Rights reserved, No Spreading abroad without Permission of ZTE 10


ZTE Low Level Design for MSAG Upgrade Project

2 MSAG Upgrade Project topology

2.1 C300M Logical Topology

The upgraded MSAG provides multiple GE/10GE ports for uplink and ring network, then the CWDM
Transmission can be removed to simplify the network. Taking consideration of reliability and user
experience, 1 to 5 AG sites in one ring is recommended. The network architecture is as below:

Figure 2-1 C300M Logical Topology

2.2 MSAG 5200 Upgrade Topology

In order to solve the problem of the power system and introduce new access service, MSAG
upgrade solution is described as below.

The existing cabinet is connected to new added cabinet with Ethernet & fiber cable, power cable.
The new service (GPON) will be introduced in enhanced MSAG shelf.

All Rights reserved, No Spreading abroad without Permission of ZTE 11


ZTE Low Level Design for MSAG Upgrade Project

The new power system in new cabinet will provide the power for new and existing cabinets, and the
old power system in MSAG will be stopped or dismantled. This solution will solve the temperature
and backup time issue.

In the new cabinet, there will be two separate spaces to completely separate the MSAG equipment
and power system. Right side cabin is for new enhanced MSAG shelf with heat exchanger. The other
cabin is for power system and battery. DC air conditioner will be deployed for battery heat
dissipation.

Figure 2-2 Old MSAG 5200 Control Boards Upgrade

Figure 2-3 Old MSAG 5200 Uplink Optimization

All Rights reserved, No Spreading abroad without Permission of ZTE 12


ZTE Low Level Design for MSAG Upgrade Project

2.3 NM Server Topology

Figure 2-4 NM server Topology

All Rights reserved, No Spreading abroad without Permission of ZTE 13


ZTE Low Level Design for MSAG Upgrade Project

Two new servers are installed to manage the new deployed MSAG. The servers work in active and
standby mode and they are installed at Kirkos and Old airport sites. Each NM server has three GE
uplinks by Ethernet cable. Two links are used for data synchronization and heart beat between two
servers. The third link is connected to CS and it’s in charge of equipment management and client
access. There are 5 PC worked as NM client.

We will deploy 42 C300M sites in Addis. The dual server should manage all devices.

2.4 Traffic flow modules

ZTE 42 MSAGs are deployed on EAAZ/SAAZ/CAAZ/NAAZ/WAAZ/CNR/SWAAZ. And they are


converged to 6 CS 8912E and 8 HuaWei ASG. These 5 CS 8912E are
Yeka 、 Bole 、 Legehar 、 Nifasilk 、 Arada and Adis Ketema.These 8 ASG are
Bole_Mchael、Kality、Akaki、Addis Ketema、Ayat、Kotebe、Hanamariam and Gerji.

2.4.1 General traffic module of HSI services

The HSI services traffic module in Addis is shown in the figure below. The new connection is
created between MSAG C300M and CS/ASG in these 14 equipment room
(Yeka 、 Bole 、 Legehar 、 Nifasilk 、 Arada 、 Adis Ketema 、 Bole_Mchael 、 Kality 、 Akaki 、 Addis

All Rights reserved, No Spreading abroad without Permission of ZTE 14


ZTE Low Level Design for MSAG Upgrade Project

Ketema 、 Ayat 、 Kotebe 、 Hanamariam and Gerji). The connection bandwidth is 10GE to the
CS/ASG. And they have to be co-site (two switches: one leg of the ring will be on CS/ASG A and
the other leg will be on CS/ASG B). The gateway of HSI is on BRAS.

IPoE & PPPoE service will adopt QinQ VLAN on MSAG C300M. Each MSAG C300M will be
assigned unique SVLAN. BRAS will terminate QinQ VLAN. VoIP service will adopt single VLAN on
MSAG. ER will terminate the single VLAN .

Old MSAG 5200 will adopt QINQ after upgrade. Both EPON/ADSL services will adopt unique
SVLAN and common CVLAN in Old MSAG 5200.

Figure 2-5 General traffic module of HSI services

2.4.2 Broadband traffic between different BRAS

The gateway of broadband is located on BRAS. The customer VLAN is terminated on BRAS. The

All Rights reserved, No Spreading abroad without Permission of ZTE 15


ZTE Low Level Design for MSAG Upgrade Project

traffic to IP-Backbone is forwarded by routing table. So it’s layer 3 network between two BRAS.

Figure 2-6 Broadband traffic between different BRAS

2.4.3 General traffic module of VoIP service

Figure 2-7 is the VOIP services traffic module in Addis. The gateway of VOIP is located on
CS/ASG. Each MSAG ring will be assigned unique VOIP VLAN. Signal and media will share the
same VLAN and IP address.

Old MSAG 5200 will keep adopt single VOIP VLAN after upgrade.

Figure 2-7 General traffic module of VoIP service

All Rights reserved, No Spreading abroad without Permission of ZTE 16


ZTE Low Level Design for MSAG Upgrade Project

There are two ZTE softswitch in Addis. They are worked in master/backup mode. When the link to
master SS is down, MSAG signal traffic will be swap to backup SS. The softswitch IP is 10.208.0.4 in
Bole. The softswitch IP is 10.209.0.4 in Kirkos.

2.4.4 Link protection diagram

Figure 2-8 Link protection diagram in MSAG ring

All Rights reserved, No Spreading abroad without Permission of ZTE 17


ZTE Low Level Design for MSAG Upgrade Project

Normally one link between MSAG is block by MSTP protocol. Otherwise the ring is formed. It can
lead to broadcast storm. The traffic module is shown as above topology. For protocol detail
information you can find in “5.3 C300M MSTP protection”.

All Rights reserved, No Spreading abroad without Permission of ZTE 18


ZTE Low Level Design for MSAG Upgrade Project

2.5 42 MSAG physical topology introduction


The phase I site list and new rings confirmed are as below Table 2-1

Table 2-1 Phase I site list

All Rights reserved, No Spreading abroad without Permission of ZTE 19


MSAG Longitu
Ring IP node Area Latitude
ID de

38.81909
NAAZ 9.023680
306 Yeka 7
ZTE Low Level Design for MSAG Upgrade Project
38.81690
EAAZ 9.019383
330 Yeka 5
1
326 Yeka NAAZ 9.020949 38.80495

322 Yeka EAAZ 9.013769 38.8075

38.82041
EAAZ 9.009396
321 Yeka 8

808 Bole EAAZ 9.0105,0 38.78945

812 Bole EAAZ 9.016270 38.79047

830 Bole EAAZ 9.01014, 38.78564


2
817 Bole EAAZ 9.009733 38.7805

38.77990
EAAZ 9.003582
806 Bole 6

789 Leghar CAAZ 9.01173 38.75652

743 Leghar CAAZ 9.00881 38.76419

3 794 Leghar CAAZ 9.00655 38.76714

737 Leghar CAAZ 9.01007 38.77266

730 Leghar CAAZ 9.0097 38.45896

793 Leghar CAAZ 9.00541 38.76727

729 Leghar CAAZ 8.99361 38.77419


4
727 Leghar CAAZ 8.99767 38.77205

720 Leghar CAAZ 9.00423 38.76876

870 Bole EAAZ 8.99861 38.78561

804 Bole EAAZ 8.99075 38.78484


5
805 Bole EAAZ 8.98106 38.77426

855 Bole EAAZ 8.99623 38.79092

6 839 Nifas Sild EAAZ 8.98128 38.77461

202 Nifas Silk SAAZ 8.96462 38.76321

201 Nifas Silk SAAZ 8.96481 38.76299

7 203 Nifas Silk SAAZ 8.97087 38.76125

222 Nifas Silk SAAZ 8.94636 38.76591

221 Nifas Silk SAAZ 8.94606 38.76498

2301 Nifas Silk SAAZ 8.93244 38.76289

2309 Nifas Silk SAAZ 8.918 38.76136


8
2307 Nifas Silk SAAZ 8.9092 38.76477

14 Nifas Silk SAAZ 8.89424 38.77222

9 630 Ketema WAAZ 9.04946 38.72447

10 485 Arada NAAZ 9.03549 38.7453

2504 abroad
All Rights reserved, No Spreading Yeka without Permission
EAAZ of9.03019
ZTE 38.87582 20

11 1640 Yeka EAAZ 9.04878 38.53102

1639 Yeka EAAZ 9.04833 38.5434


ZTE Low Level Design for MSAG Upgrade Project

For each ring there are two IP nodes to be connected, the information is shown as
following figures.

Figure 2-9 Ring 01 of New MSAG Topology

Table 2-2 Aggregation Port allocation for Ring 1

Aggregation Remote
Site Name Local Port Equipment Port

xgei-
xgei_1/19/1 111082-YK-CS-A 0/2/0/2
New MSAG-306
xgei_1/20/1 New MSAG-330 xgei_1/19/1

gei_1/19-20/3 Old MSAG-306 gei_0/9/2-3

xgei_1/19/1 New MSAG-306 xgei_1/20/1

New MSAG-326 xgei_1/20/1 New MSAG-326 xgei_1/19/1

gei_1/19-20/3 Old MSAG-330 gei_0/9/2-3

All Rights reserved, No Spreading abroad without Permission of ZTE 21


ZTE Low Level Design for MSAG Upgrade Project

Site MSTP MSTP MSTP MSTP MSTP Remark


xgei_1/19/1 New MSAG-330 xgei_1/20/1
instance instance instance instance instance
name revision number priority VLANs
New MSAG-330 xgei_1/20/1 New MSAG-322 xgei_1/19/1
111082-YK- Yeka_MSA 10 2 0 2405,2406,2 Root
CS-A G_Ring 407,2298,22
gei_1/19-20/3 Old MSAG-326 gei_0/9/2-3
99,2607,260
9,2615,3180,
xgei_1/19/1 New MSAG-326 xgei_1/20/1
3200,3204,3
630,3650,36
New MSAG-322 xgei_1/20/1 New MSAG-321 54
xgei_1/19/1
111082-YK- Yeka_MSA 10 2 4096 2405,2406,2 Backup Root
CS-B G_Ring gei_1/19-20/3 Old MSAG-322 gei_0/9/2-3
407,2298,22
99,2607,260
New MSAG-321 xgei_1/19/1 New MSAG-322 9,2615,3180,
xgei_1/20/1
3200,3204,3
xgei-
630,3650,36
xgei_1/20/1 111082-YK-CS-B 54
0/2/0/2
New Yeka_MSA 10 2 32768 2405,2406,2
MSAG_306 G_Ring gei_1/19-20/3 Old MSAG-321 gei_0/9/2-3
407,2298,22
99,2607,260
9,2615,3180,
3200,3204,3
630,3650,36
54
New Yeka_MSA 10 2 32768 2405,2406,2
MSAG_326 G_Ring 407,2298,22
99,2607,260
9,2615,3180,
3200,3204,3
630,3650,36
54
New Yeka_MSA 10 2 32768 2405,2406,2
MSAG_330 G_Ring 407,2298,22
99,2607,260
9,2615,3180,
3200,3204,3
630,3650,36
54
New Yeka_MSA 10 2 32768 2405,2406,2
MSAG_322 G_Ring 407,2298,22
99,2607,260
9,2615,3180,
3200,3204,3
630,3650,36
54
New Yeka_MSA 10 2 32768 2405,2406,2
MSAG_321 G_Ring 407,2298,22
99,2607,260
All Rights reserved, No Spreading abroad without Permission of ZTE 9,2615,3180, 22
3200,3204,3
630,3650,36
54
ZTE Low Level Design for MSAG Upgrade Project

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs

111082-YK- Yeka_MSA 10 2 0 2405,2406,2 Root


CS-A G_Ring 407,2298,22
99,2607,260
9,2615,3180,
3200,3204,3
630,3650,36
54

111082-YK- Yeka_MSA 10 2 4096 2405,2406,2 Backup Root


CS-B G_Ring 407,2298,22
99,2607,260
9,2615,3180,
3200,3204,3
630,3650,36
54
New Yeka_MSA 10 2 32768 2405,2406,2
MSAG_306 G_Ring 407,2298,22
99,2607,260
9,2615,3180,
3200,3204,3
630,3650,36
54
New Yeka_MSA 10 2 32768 2405,2406,2
MSAG_326 G_Ring 407,2298,22
99,2607,260
9,2615,3180,
3200,3204,3
630,3650,36
54
New Yeka_MSA 10 2 32768 2405,2406,2
MSAG_330 G_Ring 407,2298,22
99,2607,260
9,2615,3180,
3200,3204,3
630,3650,36
54
New Yeka_MSA 10 2 32768 2405,2406,2
MSAG_322 G_Ring 407,2298,22
99,2607,260
9,2615,3180,
3200,3204,3
630,3650,36
54
New Yeka_MSA 10 2 32768 2405,2406,2
MSAG_321 G_Ring 407,2298,22
99,2607,260
All Rights reserved, No Spreading abroad without Permission of ZTE 9,2615,3180, 23
3200,3204,3
630,3650,36
54
ZTE Low Level Design for MSAG Upgrade Project

Table 2-4 Ring 01 MSTP design(Instance 3)

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs

111082-YK- Yeka_MSA 10 3 4096 2408,2409,2 Backup Root


CS-A G_Ring 611,2667,31
95,3196,364
5,2646

111082-YK- Yeka_MSA 10 3 0 2408,2409,2 Root


CS-B G_Ring 611,2667,31
95,3196,364
5,2646
New Yeka_MSA 10 3 32768 2408,2409,2
MSAG_306 G_Ring 611,2667,31
95,3196,364
5,2646
New Yeka_MSA 10 3 32768 2408,2409,2
MSAG_326 G_Ring 611,2667,31
95,3196,364
5,2646
New Yeka_MSA 10 3 32768 2408,2409,2
MSAG_330 G_Ring 611,2667,31
95,3196,364
5,2646
New Yeka_MSA 10 3 32768 2408,2409,2
MSAG_322 G_Ring 611,2667,31
95,3196,364
5,2646
New Yeka_MSA 10 3 32768 2408,2409,2
MSAG_321 G_Ring 611,2667,31
95,3196,364
5,2646

Figure 2-10 Ring 02 of New MSAG topology

All Rights reserved, No Spreading abroad without Permission of ZTE 24


ZTE Low Level Design for MSAG Upgrade Project

Table 2-5 Aggregation Port allocation for Ring 2

Aggregation Remote
Site Name Local Port Equipment Port

xgei-
xgei_1/19/1 111136-BL-CS-A 0/2/0/2
New MSAG-806
xgei_1/20/1 New MSAG-817 xgei_1/19/1

gei_1/19-20/3 Old MSAG-806 gei_0/9/2-3

xgei_1/19/1 New MSAG-806 xgei_1/20/1

New MSAG-817 xgei_1/20/1 New MSAG-830 xgei_1/19/1

gei_1/19-20/3 Old MSAG-817 gei_0/9/2-3

xgei_1/19/1 New MSAG-817 xgei_1/20/1


New MSAG-830
xgei_1/20/1 New MSAG-812 xgei_1/19/1

All Rights reserved, No Spreading abroad without Permission of ZTE 25


ZTE Low Level Design for MSAG Upgrade Project

gei_1/19-20/3 Old MSAG-830 gei_0/9/2-3

xgei_1/19/1 New MSAG-830 xgei_1/20/1

New MSAG-812 xgei_1/20/1 New MSAG-808 xgei_1/19/1

gei_1/19-20/3 Old MSAG-812 gei_0/9/2-3

xgei_1/19/1 New MSAG-812 xgei_1/20/1

xgei-
New MSAG-808
xgei_1/20/1 111136-BL-CS-B 0/2/0/2

gei_1/19-20/3 Old MSAG-808 gei_0/9/2-3

There will be two MSTP instances in Ring 2, instance 2 will contain the BB/VOIP/MGMT service of
MSAG 5200 806/817/830,BB service of C300M 806/817/830 and VOIP/MGMT service of C300M
806/817/830/812/808. 111136-BL-CS-A will be Root of instance 2.

And instance 3 will contain the BB/VOIP/MGMT service of MSAG5200 812/808.BB service of C300M
812/808. 111136-BL-CS-B will be Root of instance 3.

Table 2-6 Ring 02 MSTP design(instance 2)

All Rights reserved, No Spreading abroad without Permission of ZTE 26


ZTE Low Level Design for MSAG Upgrade Project

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111136-BL- Bole_MSAG 20 2 0 2298,2299,2 Root
CS-A _Ring 511,2529,25
39,2590,259
1,2592,3123.
3125.3133,3
621,3622,36
27
111136-BL- Bole_MSAG 20 2 4096 2298,2299,2 Backup Root
CS-B _Ring 511,2529,25
39,2590,259
1,2592,3123.
3125.3133,3
621,3622,36
27
New Bole_MSAG 20 2 32768 2298,2299,2
MSAG_806 _Ring 511,2529,25
39,2590,259
1,2592,3123.
3125.3133,3
621,3622,36
27
New Bole_MSAG 20 2 32768 2298,2299,2
MSAG_817 _Ring 511,2529,25
39,2590,259
1,2592,3123.
3125.3133,3
621,3622,36
27
New Bole_MSAG 20 2 32768 2298,2299,2
MSAG_830 _Ring 511,2529,25
39,2590,259
1,2592,3123.
3125.3133,3
621,3622,36
27
New Bole_MSAG 20 2 32768 2298,2299,2
MSAG_812 _Ring 511,2529,25
39,2590,259
1,2592,3123.
3125.3133,3
621,3622,36
27
New Bole_MSAG 20 2 32768 2298,2299,2
MSAG_808 _Ring 511,2529,25
39,2590,259
All Rights reserved, No Spreading abroad without Permission of ZTE 1,2592,3123. 27
3125.3133,3
621,3622,36
27
ZTE Low Level Design for MSAG Upgrade Project

Table 2-7 Ring 02 MSTP design(instance 3)

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111136-BL- Bole_MSAG 20 3 4096 2503,2533,2 Backup Root
CS-A _Ring 593,2594,31
22,3128,362
5,3640
111136-BL- Bole_MSAG 20 3 0 2503,2533,2 Root
CS-B _Ring 593,2594,31
22,3128,362
5,3640
New Bole_MSAG 20 3 32768 2503,2533,2
MSAG_806 _Ring 593,2594,31
22,3128,362
5,3640
New Bole_MSAG 20 3 32768 2503,2533,2
MSAG_817 _Ring 593,2594,31
22,3128,362
5,3640
New Bole_MSAG 20 3 32768 2503,2533,2
MSAG_830 _Ring 593,2594,31
22,3128,362
5,3640
New Bole_MSAG 20 3 32768 2503,2533,2
MSAG_812 _Ring 593,2594,31
22,3128,362
5,3640
New Bole_MSAG 20 3 32768 2503,2533,2
MSAG_808 _Ring 593,2594,31
22,3128,362
5,3640

Figure 2-11 Ring 03 of New MSAG topology

All Rights reserved, No Spreading abroad without Permission of ZTE 28


ZTE Low Level Design for MSAG Upgrade Project

Table 2-8 Aggregation Port allocation for Ring 3

Aggregation Remote
Site Name Local Port Equipment Port

xgei-
xgei_1/19/1 111058-LGH-CS-A 0/2/0/4
New MSAG-789
xgei_1/20/1 New MSAG-743 xgei_1/19/1

gei_1/19-20/3 Old MSAG-789 gei_0/9/2-3

xgei_1/19/1 New MSAG-789 xgei_1/20/1

New MSAG-743 xgei_1/20/1 New MSAG-794 xgei_1/19/1

gei_1/19-20/3 Old MSAG-743 gei_0/9/2-3

xgei_1/19/1 New MSAG-743 xgei_1/20/1

New MSAG-794 xgei_1/20/1 New MSAG-737 xgei_1/19/1

gei_1/19-20/3 Old MSAG-794 gei_0/9/2-3

All Rights reserved, No Spreading abroad without Permission of ZTE 29


ZTE Low Level Design for MSAG Upgrade Project

xgei_1/19/1 New MSAG-794 xgei_1/20/1

New MSAG-737 xgei_1/20/1 New MSAG-730 xgei_1/19/1

gei_1/19-20/3 Old MSAG-737 gei_0/9/2-3

xgei_1/19/1 New MSAG-737 xgei_1/20/1


New MSAG-730
xgei-
xgei_1/20/1 111058-LGH-CS-B 0/2/0/4

gei_1/19-20/3 Old MSAG-730 gei_0/9/2-3

There will be two MSTP instances in Ring 3, instance 2 will contain the BB/VOIP/MGMT service of
MSAG 5200 789/743/794,BB service of C300M 789/743/794 and VOIP/MGMT service of C300M
789/743/794/737/730. 111058-LGH-CS-A will be Root of instance 2.

And instance 3 will contain the BB/VOIP/MGMT service of MSAG5200 737/730.BB service of C300M
737/730. 111058-LGH-CS-B will be Root of instance 3.

Table 2-9 Ring 03 MSTP design(Instance 2)

All Rights reserved, No Spreading abroad without Permission of ZTE 30


ZTE Low Level Design for MSAG Upgrade Project

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111058-LGH- Leghar_MS 30 2 0 2298,2299,2 Root
CS-A AG_Ring 300,2547,2
593,2595,27
87,2788,278
9,3194,319
9,3613,368
9,3699
111058-LGH- Leghar_MS 30 2 4096 2298,2299,2 Backup Root
CS-B AG_Ring 300,2547,2
593,2595,27
87,2788,278
9,3194,319
9,3613,368
9,3699
New Leghar_MS 30 2 32768 2298,2299,2
MSAG_789 AG_Ring 300,2547,2
593,2595,27
87,2788,278
9,3194,319
9,3613,368
9,3699
New Leghar_MS 30 2 32768 2298,2299,2
MSAG_743 AG_Ring 300,2547,2
593,2595,27
87,2788,278
9,3194,319
9,3613,368
9,3699
New Leghar_MS 30 2 32768 2298,2299,2
MSAG_794 AG_Ring 300,2547,2
593,2595,27
87,2788,278
9,3194,319
9,3613,368
9,3699
New Leghar_MS 30 2 32768 2298,2299,2
MSAG_737 AG_Ring 300,2547,2
593,2595,27
87,2788,278
9,3194,319
9,3613,368
9,3699
New Leghar_MS 30 2 32768 2298,2299,2
MSAG_730 AG_Ring 300,2547,2
593,2595,27
All Rights reserved, No Spreading abroad without Permission of ZTE 87,2788,278 31
9,3194,319
9,3613,368
9,3699
ZTE Low Level Design for MSAG Upgrade Project

Table 2-10 Ring 03 MSTP design(Instance 3)

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111058-LGH- Leghar_MS 30 3 4096 2459,2527,3 Backup Root
CS-A AG_Ring 121,2790,27
91,3138,362
1,3638
111058-LGH- Leghar_MS 30 3 0 2459,2527,3 Root
CS-B AG_Ring 121,2790,27
91,3138,362
1,3638
New Leghar_MS 30 3 32768 2459,2527,3
MSAG_789 AG_Ring 121,2790,27
91,3138,362
1,3638
New Leghar_MS 30 3 32768 2459,2527,3
MSAG_743 AG_Ring 121,2790,27
91,3138,362
1,3638
New Leghar_MS 30 3 32768 2459,2527,3
MSAG_794 AG_Ring 121,2790,27
91,3138,362
1,3638
New Leghar_MS 30 3 32768 2459,2527,3
MSAG_737 AG_Ring 121,2790,27
91,3138,362
1,3638
New Leghar_MS 30 3 32768 2459,2527,3
MSAG_730 AG_Ring 121,2790,27
91,3138,362
1,3638

Figure 2-12 Ring 04 of New MSAG topology

All Rights reserved, No Spreading abroad without Permission of ZTE 32


ZTE Low Level Design for MSAG Upgrade Project

Table 2-11 Aggregation Port allocation for Ring 4

Aggregation Remote
Site Name Local Port Equipment Port

xgei-
xgei_1/19/1 111058-LGH-CS-A 0/2/0/5
New MSAG-793
xgei_1/20/1 New MSAG-729 xgei_1/19/1

gei_1/19-20/3 Old MSAG-793 gei_0/9/2-3

xgei_1/19/1 New MSAG-793 xgei_1/20/1

New MSAG-729 xgei_1/20/1 New MSAG-727 xgei_1/19/1

gei_1/19-20/3 Old MSAG-729 gei_0/9/2-3

xgei_1/19/1 New MSAG-729 xgei_1/20/1

New MSAG-727 xgei_1/20/1 New MSAG-720 xgei_1/19/1

gei_1/19-20/3 Old MSAG-727 gei_0/9/2-3

All Rights reserved, No Spreading abroad without Permission of ZTE 33


ZTE Low Level Design for MSAG Upgrade Project

xgei_1/19/1 New MSAG-727 xgei_1/20/1

New MSAG-720 xgei_1/20/1 111058-LGH-CS-B xgei-0/2/0/5

gei_1/19-20/3 Old MSAG-720 gei_0/9/2-3

There will be two MSTP instances in Ring 4, instance 4 will contain the BB/VOIP/MGMT service of MSAG
5200 793/729,BB service of C300M 793/729 and VOIP/MGMT service of C300M 793/729/727/720. 111058-
LGH-CS-A will be Root of instance 4.

And instance 5 will contain the BB/VOIP/MGMT service of MSAG5200 727/720.BB service of C300M
727/720. 111058-LGH-CS-B will be Root of instance 5.

Table 2-12 Ring 04 MSTP design(Instance 4)

All Rights reserved, No Spreading abroad without Permission of ZTE 34


ZTE Low Level Design for MSAG Upgrade Project

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111058-LGH- Leghar_MS 30 4 0 2296,2297,2 Root
CS-A AG_Ring 592,2593,25
97,2605,318
7,3198,3690,
3694
111058-LGH- Leghar_MS 30 4 4096 2296,2297,2 Backup Root
CS-B AG_Ring 592,2593,25
97,2605,318
7,3198,3690,
3694
New Leghar_MS 30 4 32768 2296,2297,2
MSAG_793 AG_Ring 592,2593,25
97,2605,318
7,3198,3690,
3694
New Leghar_MS 30 4 32768 2296,2297,2
MSAG_729 AG_Ring 592,2593,25
97,2605,318
7,3198,3690,
3694
New Leghar_MS 30 4 32768 2296,2297,2
MSAG_727 AG_Ring 592,2593,25
97,2605,318
7,3198,3690,
3694
New Leghar_MS 30 4 32768 2296,2297,2
MSAG_720 AG_Ring 592,2593,25
97,2605,318
7,3198,3690,
3694

Table 2-13 Ring 04 MSTP design(Instance 5)

All Rights reserved, No Spreading abroad without Permission of ZTE 35


ZTE Low Level Design for MSAG Upgrade Project

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111058-LGH- Leghar_MS 30 5 4096 2499,2594,2 Backup Root
CS-A AG_Ring 595,2639,31
07,3186,360
7,3692
111058-LGH- Leghar_MS 30 5 0 2499,2594,2 Root
CS-B AG_Ring 595,2639,31
07,3186,360
7,3692
New Leghar_MS 30 5 32768 2499,2594,2
MSAG_793 AG_Ring 595,2639,31
07,3186,360
7,3692
New Leghar_MS 30 5 32768 2499,2594,2
MSAG_729 AG_Ring 595,2639,31
07,3186,360
7,3692
New Leghar_MS 30 5 32768 2499,2594,2
MSAG_727 AG_Ring 595,2639,31
07,3186,360
7,3692
New Leghar_MS 30 5 32768 2499,2594,2
MSAG_720 AG_Ring 595,2639,31
07,3186,360
7,3692

Figure 2-13 Ring 05 of New MSAG topology

All Rights reserved, No Spreading abroad without Permission of ZTE 36


ZTE Low Level Design for MSAG Upgrade Project

Table 2-14 Aggregation Port allocation for Ring 5

Aggregation Remote
Site Name Local Port Equipment Port

xgei-
xgei_1/19/1 111136-BL-CS-A 0/2/0/6
New MSAG-870
xgei_1/20/1 New MSAG-804 xgei_1/19/1

gei_1/19-20/3 Old MSAG-870 gei_0/9/2-3

xgei_1/19/1 New MSAG-870 xgei_1/20/1

New MSAG-804 xgei_1/20/1 New MSAG-805 xgei_1/19/1

gei_1/19-20/3 Old MSAG-804 gei_0/9/2-3

xgei_1/19/1 New MSAG-804 xgei_1/20/1

New MSAG-805 xgei_1/20/1 New MSAG-855 xgei_1/19/1

gei_1/19-20/3 Old MSAG-805 gei_0/9/2-3

New MSAG-855 xgei_1/19/1 New MSAG-805 xgei_1/20/1

All Rights reserved, No Spreading abroad without Permission of ZTE 37


ZTE Low Level Design for MSAG Upgrade Project

xgei_1/20/1 111136-BL-CS-B xgei-0/2/0/6

gei_1/19-20/3 Old MSAG-855 gei_0/9/2-3

There will be two MSTP instances in Ring 5, instance 4 will contain the BB/VOIP/MGMT service of MSAG
5200 870/804,BB service of C300M 870/804 and VOIP/MGMT service of C300M 870/804/805/855. 111136-
BL-CS-A will be Root of instance 4.

And instance 5 will contain the BB/VOIP/MGMT service of MSAG5200 805/855.BB service of C300M
805/855. 111136-BL-CS-B will be Root of instance 5.

Table 2-15 Ring 05 MSTP design(Instance 4)

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111136-BL- Bole_MSAG 20 4 0 2296,2297,2 Root
CS-A _Ring 427,2499,25
95,2596,310
2,3120,3602,
3634
111136-BL- Bole_MSAG 20 4 4096 2296,2297,2 Backup Root
CS-B _Ring 427,2499,25
95,2596,310
2,3120,3602,
3634
New Bole_MSAG 20 4 32768 2296,2297,2
MSAG_870 _Ring 427,2499,25
95,2596,310
2,3120,3602,
3634
New Bole_MSAG 20 4 32768 2296,2297,2
MSAG_804 _Ring 427,2499,25
95,2596,310
2,3120,3602,
3634
New Bole_MSAG 20 4 32768 2296,2297,2
MSAG_805 _Ring 427,2499,25
95,2596,310
2,3120,3602,
3634
New Bole_MSAG 20 4 32768 2296,2297,2
MSAG_855 _Ring 427,2499,25
All Rights reserved, No Spreading abroad without Permission of ZTE 95,2596,310 38
2,3120,3602,
3634
ZTE Low Level Design for MSAG Upgrade Project

Table 2-16 Ring 05 MSTP design(Instance 5)

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111136-BL- Bole_MSAG 20 5 4096 2435,2497,2 Backup Root
CS-A _Ring 597,2598,31
21,3136,361
9,3620
111136-BL- Bole_MSAG 20 5 0 2435,2497,2 Root
CS-B _Ring 597,2598,31
21,3136,361
9,3620
New Bole_MSAG 20 5 32768 2435,2497,2
MSAG_870 _Ring 597,2598,31
21,3136,361
9,3620
New Bole_MSAG 20 5 32768 2435,2497,2
MSAG_804 _Ring 597,2598,31
21,3136,361
9,3620
New Bole_MSAG 20 5 32768 2435,2497,2
MSAG_805 _Ring 597,2598,31
21,3136,361
9,3620
New Bole_MSAG 20 5 32768 2435,2497,2
MSAG_855 _Ring 597,2598,31
21,3136,361
9,3620

Figure 2-14 Ring 06 of New MSAG topology

All Rights reserved, No Spreading abroad without Permission of ZTE 39


ZTE Low Level Design for MSAG Upgrade Project

Table 2-17 Aggregation Port allocation for Ring 6

Aggregation Remote
Site Name Local Port Equipment Port

111010_Bole_Mch GigabitEth
xgei_1/19/1 ael_ASG_A ernet8/0/3

New MSAG-839 111010_Bole_Mch GigabitEther


xgei_1/20/1 ael_ASG_B net8/0/3

gei_1/19-20/3 Old MSAG-839 gei_0/9/2-3

There will be two MSTP instances in Ring 6, instance 2 will contain the BB/VOIP/MGMT service of MSAG
5200 839,111010_Bole_Mchael_ASG_A will be Root of instance 2.

And instance 3 will contain the BB/VOIP/MGMT service of C300M 839. 111010_Bole_Mchael_ASG_B will
be Root of instance 3.

Table 2-18 Ring 06 MSTP design(Instance 2)

All Rights reserved, No Spreading abroad without Permission of ZTE 40


ZTE Low Level Design for MSAG Upgrade Project

Table 2-19 Ring 06 MSTP design(Instance 3)

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
Site MSTP
name MSTP
revision MSTP
number MSTP
priority MSTP
VLANs Remark
instance instance instance instance instance
111010_Bole_ NS_MSAG_
name 40
revision 2
number 0
priority 2721,3207,3
VLANs Root
Mchael_ASG Ring 601
111010_Bole_
_A NS_MSAG_ 40 3 4096 2290,2291,2 Backup Root
Mchael_ASG Ring 600
111010_Bole_
_A NS_MSAG_ 40 2 4096 2721,3207,3 Backup Root
Mchael_ASG Ring 601
111010_Bole_
_B NS_MSAG_ 40 3 0 2290,2291,2 Root
Mchael_ASG Ring 600
_B New NS_MSAG_ 40 2 32768 2721,3207,3
MSAG_839 Ring 601
New NS_MSAG_ 40 3 32768 2290,2291,2
MSAG_839 Ring 600

Figure 2-15 Ring 07 of New MSAG topology

Table 2-20 Aggregation Port allocation for Ring 7

Site Name Local Port Aggregation Remote

All Rights reserved, No Spreading abroad without Permission of ZTE 41


ZTE Low Level Design for MSAG Upgrade Project

Equipment Port

xgei-
xgei_1/19/1 111007-NS-CS-A 0/2/0/3
New MSAG-202
xgei_1/20/1 New MSAG-201 xgei_1/19/1

gei_1/19-20/3 Old MSAG-202 gei_0/9/2-3

xgei_1/19/1 New MSAG-202 xgei_1/20/1

New MSAG-201 xgei_1/20/1 New MSAG-203 xgei_1/19/1

gei_1/19-20/3 Old MSAG-201 gei_0/9/2-3

xgei_1/19/1 New MSAG-201 xgei_1/20/1

New MSAG-203 xgei_1/20/1 New MSAG-222 xgei_1/19/1

gei_1/19-20/3 Old MSAG-203 gei_0/9/2-3

xgei_1/19/1 New MSAG-203 xgei_1/20/1

New MSAG-222 xgei_1/20/1 New MSAG-221 xgei_1/19/1

gei_1/19-20/3 Old MSAG-222 gei_0/9/2-3

xgei_1/19/1 New MSAG-222 xgei_1/20/1

xgei-
New MSAG-221
xgei_1/20/1 111007-NS-CS-B 0/2/0/3

gei_1/19-20/3 Old MSAG-221 gei_0/9/2-3

There will be two MSTP instances in Ring 7, instance 4 will contain the BB/VOIP/MGMT service of MSAG
5200 202/201/203,BB service of C300M 202/201/203 and VOIP/MGMT service of C300M
202/201/203/222/221. 111007-NS-CS-A will be Root of instance 4.

And instance 5 will contain the BB/VOIP/MGMT service of MSAG5200 222/221.BB service of C300M
222/221. 111007-NS-CS-B will be Root of instance 5.

All Rights reserved, No Spreading abroad without Permission of ZTE 42


ZTE Low Level Design for MSAG Upgrade Project

Table 2-21 Ring 07 MSTP design(Instance 4)

All Rights reserved, No Spreading abroad without Permission of ZTE 43


ZTE Low Level Design for MSAG Upgrade Project

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111007-NS- NS_MSAG_ 40 4 0 2298,2299,2 Root
CS-A Ring 391,2392,23
93,2557,261
1,2613,3100,
3101,3102,3
606,3607,36
08
111007-NS- NS_MSAG_ 40 4 4096 2298,2299,2 Backup Root
CS-B Ring 391,2392,23
93,2557,261
1,2613,3100,
3101,3102,3
606,3607,36
08
New NS_MSAG_ 40 4 32768 2298,2299,2
MSAG_202 Ring 391,2392,23
93,2557,261
1,2613,3100,
3101,3102,3
606,3607,36
08
New NS_MSAG_ 40 4 32768 2298,2299,2
MSAG_201 Ring 391,2392,23
93,2557,261
1,2613,3100,
3101,3102,3
606,3607,36
08
New NS_MSAG_ 40 4 32768 2298,2299,2
MSAG_203 Ring 391,2392,23
93,2557,261
1,2613,3100,
3101,3102,3
606,3607,36
08
New NS_MSAG_ 40 4 32768 2298,2299,2
MSAG_222 Ring 391,2392,23
93,2557,261
1,2613,3100,
3101,3102,3
606,3607,36
08
New NS_MSAG_ 40 4 32768 2298,2299,2
MSAG_221 Ring 391,2392,23
93,2557,261
All Rights reserved, No Spreading abroad without Permission of ZTE 1,2613,3100, 44
3101,3102,3
606,3607,36
08
ZTE Low Level Design for MSAG Upgrade Project

Table 2-22 Ring 07 MSTP design(Instance 5)

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111007-NS- NS_MSAG_ 40 5 4096 2394,2395,2 Backup Root
CS-A Ring 601,2603,31
18,3119,362
4,2625
111007-NS- NS_MSAG_ 40 5 0 2394,2395,2 Root
CS-B Ring 601,2603,31
18,3119,362
4,2625
New NS_MSAG_ 40 5 32768 2394,2395,2
MSAG_202 Ring 601,2603,31
18,3119,362
4,2625
New NS_MSAG_ 40 5 32768 2394,2395,2
MSAG_201 Ring 601,2603,31
18,3119,362
4,2625
New NS_MSAG_ 40 5 32768 2394,2395,2
MSAG_203 Ring 601,2603,31
18,3119,362
4,2625
New NS_MSAG_ 40 5 32768 2394,2395,2
MSAG_222 Ring 601,2603,31
18,3119,362
4,2625
New NS_MSAG_ 40 5 32768 2394,2395,2
MSAG_221 Ring 601,2603,31
18,3119,362
4,2625

Figure 2-16 Ring 08 of New MSAG topology

All Rights reserved, No Spreading abroad without Permission of ZTE 45


ZTE Low Level Design for MSAG Upgrade Project

Table 2-23 Aggregation Port allocation for Ring 8

Aggregation Remote
Site Name Local Port Equipment Port

111767_Kality_AS GigabitEth
xgei_1/19/1 G_A ernet8/2/0
New MSAG-2301
xgei_1/20/1 New MSAG-2309 xgei_1/19/1

gei_1/19-20/3 Old MSAG-2301 gei_0/9/2-3

xgei_1/19/1 New MSAG-2301 xgei_1/20/1

New MSAG-2309 xgei_1/20/1 New MSAG-2307 xgei_1/19/1

gei_1/19-20/3 Old MSAG-2309 gei_0/9/2-3

xgei_1/19/1 New MSAG-2309 xgei_1/20/1

New MSAG-2307 xgei_1/20/1 New MSAG-214 xgei_1/19/1

gei_1/19-20/3 Old MSAG-2307 gei_0/9/2-3

All Rights reserved, No Spreading abroad without Permission of ZTE 46


ZTE Low Level Design for MSAG Upgrade Project

xgei_1/19/1 New MSAG-2307 xgei_1/20/1

111408_Akaki_AS GigabitEth
New MSAG-14
xgei_1/20/1 G_A ernet8/0/2

gei_1/19-20/3 Old MSAG-14 gei_0/9/2-3

There will be two MSTP instances in Ring 8, instance 6 will contain the BB/VOIP/MGMT service of MSAG
5200 2301/2309,BB service of C300M 2301/2309 and VOIP/MGMT service of C300M
2301/2309/2307/14.111767_Kality_ASG_A will be Root of instance 6.

And instance 7 will contain the BB/VOIP/MGMT service of MSAG5200 2307/14.BB service of C300M
2307/14.111408_Akaki_ASG_A will be Root of instance 7.

Table 2-24 Ring 08 MSTP design(Instance 6)

All Rights reserved, No Spreading abroad without Permission of ZTE 47


ZTE Low Level Design for MSAG Upgrade Project

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111767_Kality NS_MSAG_ 40 6 0 2296,2297,2 Root
_ASG_A Ring 396,2397,25
29,2647,319
4,3202,3635,
3643
111408_Akaki NS_MSAG_ 40 6 4096 2296,2297,2 Backup Root
_ASG_A Ring 396,2397,25
29,2647,319
4,3202,3635,
3643
New NS_MSAG_ 40 6 32768 2296,2297,2
MSAG_2301 Ring 396,2397,25
29,2647,319
4,3202,3635,
3643
New NS_MSAG_ 40 6 32768 2296,2297,2
MSAG_2309 Ring 396,2397,25
29,2647,319
4,3202,3635,
3643
New NS_MSAG_ 40 6 32768 2296,2297,2
MSAG_2307 Ring 396,2397,25
29,2647,319
4,3202,3635,
3643
New NS_MSAG_ 40 6 32768 2296,2297,2
MSAG_14 Ring 396,2397,25
29,2647,319
4,3202,3635,
3643

Table 2-25 Ring 08 MSTP design(Instance 7)

All Rights reserved, No Spreading abroad without Permission of ZTE 48


ZTE Low Level Design for MSAG Upgrade Project

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111767_Kality NS_MSAG_ 40 7 4096 2398,2399,2 Backup Root
_ASG_A Ring 535,2683,31
62,3200,364
1,3659
111408_Akaki NS_MSAG_ 40 7 0 2398,2399,2 Root
_ASG_A Ring 535,2683,31
62,3200,364
1,3659
New NS_MSAG_ 40 7 32768 2398,2399,2
MSAG_2301 Ring 535,2683,31
62,3200,364
1,3659
New NS_MSAG_ 40 7 32768 2398,2399,2
MSAG_2309 Ring 535,2683,31
62,3200,364
1,3659
New NS_MSAG_ 40 7 32768 2398,2399,2
MSAG_2307 Ring 535,2683,31
62,3200,364
1,3659
New NS_MSAG_ 40 7 32768 2398,2399,2
MSAG_14 Ring 535,2683,31
62,3200,364
1,3659

Figure 2-17 Ring 09 of New MSAG topology

All Rights reserved, No Spreading abroad without Permission of ZTE 49


ZTE Low Level Design for MSAG Upgrade Project

Table 2-26 Aggregation Port allocation for Ring 9

Aggregation Remote
Site Name Local Port Equipment Port

111057_Addis_Ket GigabitEth
xgei_1/19/1 ema_ASG_A ernet8/2/1

New MSAG-630 111057_Addis_Ket GigabitEth


xgei_1/20/1 ema_ASG_B ernet8/2/1

gei_1/19-20/3 Old MSAG-630 gei_0/9/2-3

There will be two MSTP instances in Ring 9, instance 2 will contain the BB/VOIP/MGMT service of MSAG
5200 630,111057_Addis_Ketema_ASG_A will be Root of instance 2.

And instance 3 will contain the BB/VOIP/MGMT service of C300M 630. 111057_Addis_Ketema_ASG_B will
be Root of instance 3.

Table 2-27 Ring 09 MSTP design(Instance 2)

All Rights reserved, No Spreading abroad without Permission of ZTE 50


ZTE Low Level Design for MSAG Upgrade Project

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111057_Addis KT_MSAG_ 50 2 0 2483,3109,3 Root
_Ketema_AS Ring 608
G_A
111057_Addis KT_MSAG_ 50 2 4096 2483,3109,3 Backup Root
_Ketema_AS Ring 608
G_B
New KT_MSAG_ 50 2 32768 2483,3109,3
MSAG_630 Ring 608

Table 2-28 Ring 09 MSTP design(Instance 3)

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111057_Addis KT_MSAG_ 50 3 4096 2298,2299,2 Backup Root
_Ketema_AS Ring 400
G_A
111057_Addis KT_MSAG_ 50 3 0 2298,2299,2 Root
_Ketema_AS Ring 400
G_B
New KT_MSAG_ 50 3 32768 2298,2299,2
MSAG_630 Ring 400

Figure 2-18 Ring 10 of New MSAG topology

All Rights reserved, No Spreading abroad without Permission of ZTE 51


ZTE Low Level Design for MSAG Upgrade Project

Table 2-29 Aggregation Port allocation for Ring 10

Aggregation Remote
Site Name Local Port Equipment Port

xgei-
xgei_1/19/1 111055-AD-CS-A 0/2/0/4

New MSAG-485 xgei-


xgei_1/20/1 111055-AD-CS-B 0/2/0/4

gei_1/19-20/3 Old MSAG-485 gei_0/9/2-3

There will be two MSTP instances in Ring 10, instance 2 will contain the BB/VOIP/MGMT service of MSAG
5200 485,111055-AD-CS-A will be Root of instance 2.

And instance 3 will contain the BB/VOIP/MGMT service of C300M 485. 111055-AD-CS-B will be Root of
instance 3.

Table 2-30 Ring 10 MSTP design(Instance 2)

All Rights reserved, No Spreading abroad without Permission of ZTE 52


ZTE Low Level Design for MSAG Upgrade Project

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111055-AD- ARADA_MS 60 2 0 2443,3100 Root
CS-A AG_Ring ,2611
111055-AD- ARADA_MS 60 2 4096 2443,3100 Backup Root
CS-B AG_Ring ,2611
New ARADA_MS 60 2 32768 2443,3100
MSAG_485 AG_Ring ,2611

Table 2-31 Ring 10 MSTP design(Instance 3)

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111055-AD- ARADA_MS 60 3 4096 2298,2299 Backup Root
CS-A AG_Ring ,2691
111055-AD- ARADA_MS 60 3 0 2298,2299 Root
CS-B AG_Ring ,2691
New ARADA_MS 60 3 32768 2298,2299
MSAG_485 AG_Ring ,2691

Figure 2-19 Ring 11 of New MSAG topology

All Rights reserved, No Spreading abroad without Permission of ZTE 53


ZTE Low Level Design for MSAG Upgrade Project

Table 2-32 Aggregation Port allocation for Ring 11

Aggregation Remote
Site Name Local Port Equipment Port

111165_Ayat_ASG GigabitEth
xgei_1/19/1 _A ernet8/0/4
New MSAG-2504
xgei_1/20/1 New MSAG-1640 xgei_1/19/1

gei_1/19-20/3 Old MSAG-2504 gei_0/9/2-3

xgei_1/19/1 New MSAG-2504 xgei_1/20/1

New MSAG-1640 xgei_1/20/1 New MSAG-1639 xgei_1/19/1

gei_1/19-20/3 Old MSAG-1640 gei_0/9/2-3

xgei_1/19/1 New MSAG-1640 xgei_1/20/1

111086_Kotebe_A GigabitEther
New MSAG-1639
xgei_1/20/1 SG_A net8/0/4

gei_1/19-20/3 Old MSAG-1639 gei_0/9/2-3

All Rights reserved, No Spreading abroad without Permission of ZTE 54


ZTE Low Level Design for MSAG Upgrade Project

There will be two MSTP instances in Ring 11, instance 4 will contain the BB/VOIP/MGMT service of MSAG
5200 2504/1640,BB service of C300M 2504/1640 and VOIP/MGMT service of C300M
2504/1640/1639.111165_Ayat_ASG_A will be Root of instance 4.

And instance 5 will contain the BB/VOIP/MGMT service of MSAG5200 1639.BB service of C300M
1639.111086_Kotebe_ASG_A will be Root of instance 5.

Table 2-33 Ring 11 MSTP design(Instance 4)

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111165_Ayat_ Yeka_MSA 10 4 0 2296,229724 Root
ASG_A G_Ring 10,2411,253
3,2781,3140,
3144,3603,3
715
111086_Kote Yeka_MSA 10 4 4096 2296,229724 Backup Root
be_ASG_A G_Ring 10,2411,253
3,2781,3140,
3144,3603,3
715
New Yeka_MSA 10 4 32768 2296,229724
MSAG_2504 G_Ring 10,2411,253
3,2781,3140,
3144,3603,3
715
New Yeka_MSA 10 4 32768 2296,229724
MSAG_1640 G_Ring 10,2411,253
3,2781,3140,
3144,3603,3
715
New Yeka_MSA 10 4 32768 2296,229724
MSAG_1639 G_Ring 10,2411,253
3,2781,3140,
3144,3603,3
715

Table 2-34 Ring 11 MSTP design(Instance 5)

All Rights reserved, No Spreading abroad without Permission of ZTE 55


ZTE Low Level Design for MSAG Upgrade Project

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111165_Ayat_ Yeka_MSA 10 5 4096 2412,2779,3 Backup Root
ASG_A G_Ring 139,3714
111086_Kote Yeka_MSA 10 5 0 2412,2779,3 Root
be_ASG_A G_Ring 139,3714
New Yeka_MSA 10 5 32768 2412,2779,3
MSAG_2504 G_Ring 139,3714
New Yeka_MSA 10 5 32768 2412,2779,3
MSAG_1640 G_Ring 139,3714
New Yeka_MSA 10 5 32768 2412,2779,3
MSAG_1639 G_Ring 139,3714

Figure 2-20 Ring 12 of New MSAG topology

Table 2-35 Aggregation Port allocation for Ring 12

Site Name Local Port


Aggregation Remote

All Rights reserved, No Spreading abroad without Permission of ZTE 56


ZTE Low Level Design for MSAG Upgrade Project

Equipment Port

111120_Hanamaria GigabitEth
xgei_1/19/1 m_ASG_A ernet8/2/0

New MSAG-1913 111120_Hanamaria GigabitEth


xgei_1/20/1 m_ASG_A ernet8/2/0

gei_1/19-20/3 Old MSAG-1913 gei_0/9/2-3

There will be two MSTP instances in Ring 12, instance 8 will contain the BB/VOIP/MGMT service of MSAG
5200 1913,111120_Hanamariam_ASG_A will be Root of instance 8.

And instance 9 will contain the BB/VOIP/MGMT service of C300M 1913. 111120_Hanamariam_ASG_B will
be Root of instance 9.

Table 2-36 Ring 12 MSTP design(Instance 8)

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs

111120_Hana NS_MSAG_ 40 8 0 2483,3187,3 Root


mariam_ASG Ring 686
_A
111120_Hana NS_MSAG_ 40 8 4096 2483,3187,3 Backup Root
mariam_ASG Ring 686
_B
New NS_MSAG_ 40 8 32768 2483,3187,3
MSAG_1913 Ring 686

Table 2-37 Ring 12 MSTP design(Instance 9)

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111120_Hana NS_MSAG_ 40 9 4096 2294,2295,2 Backup Root
mariam_ASG Ring 400
_A
111120_Hana NS_MSAG_ 40 9 0 2294,2295,2 Root
mariam_ASG Ring 400
All Rights
_B reserved, No Spreading abroad without Permission of ZTE 57

New NS_MSAG_ 40 9 32768 2294,2295,2


MSAG_1913 Ring 400
ZTE Low Level Design for MSAG Upgrade Project

Figure 2-21 Ring 13 of New MSAG topology

Table 2-38 Aggregation Port allocation for Ring 13

Aggregation Remote
Site Name Local Port Equipment Port

111089_Gerji_ASG GigabitEth
xgei_1/19/1 _A ernet8/0/4

New MSAG-1102 111089_Gerji_ASG GigabitEth


xgei_1/20/1 _B ernet8/0/4

gei_1/19-20/3 Old MSAG-1102 gei_0/9/2-3

There will be two MSTP instances in Ring 13, instance 6 will contain the BB/VOIP/MGMT service of MSAG
5200 1102,111089_Gerji_ASG_A will be Root of instance 6.

And instance 7 will contain the BB/VOIP/MGMT service of C300M 1102. 111089_Gerji_ASG_B will be Root
of instance 7.

Table 2-39 Ring 13 MSTP design(Instance 6)

All Rights reserved, No Spreading abroad without Permission of ZTE 58


ZTE Low Level Design for MSAG Upgrade Project

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111089_Gerji Yeka_MSA 10 6 0 2469,3158,3 Root
_ASG_A G_Ring 610
111089_Gerji Yeka_MSA 10 6 4096 2469,3158,3 Backup Root
_ASG_B G_Ring 610
New Yeka_MSA 10 6 32768 2469,3158,3
MSAG_1102 G_Ring 610

Table 2-40 Ring 13 MSTP design(Instance 7)

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111089_Gerji Yeka_MSA 10 7 4096 2292,2293,2 Backup Root
_ASG_A G_Ring 601
111089_Gerji Yeka_MSA 10 7 0 2292,2293,2 Root
_ASG_B G_Ring 601
New Yeka_MSA 10 7 32768 2292,2293,2
MSAG_1102 G_Ring 601

Figure 2-22 Ring 14 of New MSAG topology

All Rights reserved, No Spreading abroad without Permission of ZTE 59


ZTE Low Level Design for MSAG Upgrade Project

Table 2-41 Aggregation Port allocation for Ring 14

Aggregation Remote
Site Name Local Port Equipment Port

xgei-
xgei_1/19/1 111055-AD-CS-A 0/2/0/5
New MSAG-469
xgei_1/20/1 New MSAG-490 xgei_1/19/1

gei_1/19-20/3 Old MSAG-469 gei_0/9/2-3

xgei_1/19/1 New MSAG-469 xgei_1/20/1

New MSAG-490 xgei_1/20/1 111055-AD-CS-B xgei-0/2/0/5

gei_1/19-20/3 Old MSAG-490 gei_0/9/2-3

There will be two MSTP instances in Ring 14, instance 4 will contain the BB/VOIP/MGMT service of
MSAG 5200 469,BB service of C300M 469 and VOIP/MGMT service of C300M 469/490.111055-AD-
CS-A will be Root of instance 4.

And instance 5 will contain the BB/VOIP/MGMT service of MSAG5200 490.BB service of C300M
490.111055-AD-CS-A will be Root of instance 5.

All Rights reserved, No Spreading abroad without Permission of ZTE 60


ZTE Low Level Design for MSAG Upgrade Project

Table 2-42 Ring 14 MSTP design(Instance 4)

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111055-AD- ARADA_MS 60 3 0 2294,2296,2 Root
CS-A AG_Ring 457,2689,31
31,3642
111055-AD- ARADA_MS 60 3 4096 2294,2296,2 Backup Root
CS-B AG_Ring 457,2689,31
31,3642
New ARADA_MS 60 3 32768 2294,2296,2
MSAG_469 AG_Ring 457,2689,31
31,3642
New ARADA_MS 60 3 32768 2294,2296,2
MSAG_490 AG_Ring 457,2689,31
31,3642

Table 2-43 Ring 14 MSTP design(Instance 5)

All Rights reserved, No Spreading abroad without Permission of ZTE 61


ZTE Low Level Design for MSAG Upgrade Project

Site MSTP MSTP MSTP MSTP MSTP Remark


instance instance instance instance instance
name revision number priority VLANs
111055-AD- ARADA_MS 60 5 4096 2489,2690,3 Backup Root
CS-A AG_Ring 116,3627
111055-AD- ARADA_MS 60 5 0 2489,2690,3 Root
CS-B AG_Ring 116,3627
New ARADA_MS 60 5 32768 2489,2690,3
MSAG_469 AG_Ring 116,3627
New ARADA_MS 60 5 32768 2489,2690,3
MSAG_490 AG_Ring 116,3627

3 Hardware and Software Infrastructure Design

3.1 Hardware Infrastructure Design

3.1.1 C300M Hardware Infrastructure Design

Overall Architecture

The core technology in ZXA10 C300M is TDM + IP. It supports two switching types:

 Circuit switching

 Ethernet switching

Figure 3-23 ZXA10 C300M working principle

All Rights reserved, No Spreading abroad without Permission of ZTE 62


ZTE Low Level Design for MSAG Upgrade Project

As shown in Figure 3-1, the outmost block represents the system boundary. The dotted frame
represents the card functions. The dotted frame at the lower-right corner represents the sub-card on the
main control card.

At the user side, ZXA10 C300M provides POTS, ISDN, and xDSL access. At the network side, ZXA10
C300M provides IP uplink.

ZXA10 C300M working principle is as follows:

 Narrowband service data enters the TDM switching module of SCXN card.

 TDM switching module performs circuit switching on the voice signals and sends them
to VoIP processing card.

 VoIP processing card converts voice traffic into IP packets and sends them to Ethernet
switching module.

 Ethernet switching chip switches the IP packets and send them to NAT module for
network address translation.

 IP packets enter the IP network through an uplink interface after Ethernet switching.

 Broadband service data enters Ethernet switching chip of control and switching card
and directly goes to IP network through an uplink interface.

All Rights reserved, No Spreading abroad without Permission of ZTE 63


ZTE Low Level Design for MSAG Upgrade Project

MSAG C300M Dimension

The dimensions of 19-inch service shelf are 443.7 mm × 482.6 mm × 270 mm (Height × Width × Depth).

Figure 3-24 Appearance of ZXA10 C300M IEC 19” Service Shelf

As it is shown in the figure, the leftmost slots are Slots 0 and 1. Slot 0 and 1 are dedicated for the
power cards. The rightmost slots are Slots 19 and 20, which are dedicated for the network
interface cards.

Figure 3-25 Layout of ZXA10 C300M IEC 19” Service Shelf

All Rights reserved, No Spreading abroad without Permission of ZTE 64


ZTE Low Level Design for MSAG Upgrade Project

Table 3-44 IEC 19-inch Shelf Configuration

Slot Card Description

0/1 Power card Slots of 4.5U height, used for the


power cards

2–9 Line card

10/11 Control and switch card

12 – 17 Line card

18 Common interface card Slot used for the common interface


card, providing clock output/input
interface, management interface,
and monitoring interface
(environment, power, and other
parameters)

19/20 Ethernet uplink card of Providing FE, GE, 10GE Ethernet


4.5U height uplink interfaces

All Rights reserved, No Spreading abroad without Permission of ZTE 65


ZTE Low Level Design for MSAG Upgrade Project

Internal Physical Connection

The user lines are connected to MDF and extended to user’s side.

Figure 3-26 ZXA10 C300M inner physical connection

Connection between master shelf and slave shelf

The uplink card of master shelf is connected to the uplink card of slave shelves. One pair of cascade
cables work in either 1+1 or 1:1 protection mode.

Figure 3-27 Then connection between master shelf and slave shelf

All Rights reserved, No Spreading abroad without Permission of ZTE 66


ZTE Low Level Design for MSAG Upgrade Project

LC cards

LC: Line Card, including narrowband line card and broadband line card.

Table 3-45 Card list in ET Phase 4 Project

Card Function Capability


SCXN System control and switching  System kernel of services
and management

 Local and remote OAM

 Active / Standby
redundancy

 Load sharing

 10 GE to any subscriber
card(for each card)

All Rights reserved, No Spreading abroad without Permission of ZTE 67


ZTE Low Level Design for MSAG Upgrade Project

PTWV 64-port POTS subscriber card 64 subscriber ports on the


front panel; Build-in line test
APWV 64-port ADSL2+ over POTS 64 ADSL2+ over POTS
subscriber card with built-in service channels (built-in
splitters splitters)
ACWK 48-port ADSL2+ and POTS 48 subscriber ports on the
COMBO subscriber card (built-in front panel
splitter)
VCWK 48-port VDSL2 and POTS 48 subscriber ports on the
COMBO subscriber card front panel (It’s configured in
test bed)
 16 SHDSL.TDM service
channels

16-port SHDSL TDM balanced  16 E1 (balanced interface )


DSWB
interface card service channels

 ISDN PRI

PRWG Power card Power interface;


Test bus port; two RJ-45 ports
VOPSF VoIP Processing Sub-Card 512 RTP resources

GUSQ Ethernet Uplink 2 x 1000Base-FX and 2 x


10/100/1000Base-T ports
Uplinks
GUFQ Ethernet Uplink 4 x 1000Base-FX ports
Uplinks
CICK Common interface, Environment BITS clock interfaces,
Monitor Maintenance interfaces,
Temperature/ Humidity/ Smog/
Flood/ Entrance sensor
interfaces.

All Rights reserved, No Spreading abroad without Permission of ZTE 68


ZTE Low Level Design for MSAG Upgrade Project

Table 3-46 Sites detail information

GPON(GTG Type of
MSAG No/Name TYPE
HK) MSAG

New MSAG-306 C300M 16 Outdoor

New MSAG-330 C300M 16 Outdoor

New MSAG-326 C300M 16 Outdoor

New MSAG-322 C300M 16 Outdoor

New MSAG-321 C300M 16 Outdoor

New MSAG-808 C300M 16 Outdoor

New MSAG-812 C300M 16 Outdoor

New MSAG-830 C300M 16 Outdoor

New MSAG-817 C300M 16 Outdoor

New MSAG-806 C300M 16 Outdoor

All Rights reserved, No Spreading abroad without Permission of ZTE 69


ZTE Low Level Design for MSAG Upgrade Project

3.2 Software Infrastructure Design

3.2.1 C300M Software Infrastructure Design

Figure 3-6 shows the ZXA10 C300M software architecture.

Figure 3-28 Software Architecture

Table 3-4 describes the subsystem functions of the overall software architecture of the ZXA10
C300M&C350M system.

Table 3-47 Subsystem Description of the Software Architecture

All Rights reserved, No Spreading abroad without Permission of ZTE 70


ZTE Low Level Design for MSAG Upgrade Project

Sub Module Functionality Description


Operation and
The operation and management subsystem is on the highest
management
layer of the total system software. It supports the SNMP
subsystem
management and CLI management and provides inner
interface for the operation and maintenance platform. The
network element can be managed by a serial port terminal, a
telnet/ssh connection or ZTE EMS.

Service
The service subsystem is in the core layer of the total system
subsystem
software. It is responsible for the implementation of relevant
services. The service subsystem consists of the broadband
protocol subsystem and the narrowband protocol subsystem.

Protocol
The protocol subsystem implements TCP, UDP, IP, ICMP,
subsystem
ARP, RARP, TFTP, FTP, SNMP, Telnet, IGMP, MSTP, and
other protocols.

Bearer
Detection of subscriber circuits
subsystem

Subscriber circuit testing

Announcement play

DTMF digit receiving

ISDN subscribers message collection and forwarding

VoIP coding & decoding

16K switching network connection

xDSL subscriber configuration management

Specific function interfaces to the upper layer

All Rights reserved, No Spreading abroad without Permission of ZTE 71


ZTE Low Level Design for MSAG Upgrade Project

Sub Module Functionality Description


Operation
System control
support
subsystem
Intra-card and inter-card communications

Version management

Task and process management

Memory management

Timer management

File system management

Operating
The real-time operating system consists of board support
system
package and drivers, supporting the upper-layer subsystem.

All Rights reserved, No Spreading abroad without Permission of ZTE 72


ZTE Low Level Design for MSAG Upgrade Project

4 Cabinet List and Dimensioning

4.1 EC40CE Outdoor Cabinet (C300M)

ZTE EC40CE Cabinet is an outdoor cabinet that is used for installing integrated access devices
the ZXA10 C300M and providing a reliable operating environment for them. It dissipates heat
through the heat exchanger. Figure 4-2 shows the appearance of ZTE EC40CE Cabinet:

Table 4-48 Dimensions of ZTE EC40CE Cabinet

Item Dimensions (mm)

Cabinet 1680 (H) x 1500 (W) x 750 (D)


Battery section 1050(H) × 570 (W) × 570(D)
Full configuration weight 500kg

Main device installation space Width: 19 inch, height: 31U

Figure 4-29 EC40CE Cabinet

All Rights reserved, No Spreading abroad without Permission of ZTE 73


ZTE Low Level Design for MSAG Upgrade Project

Figure 4-30 Cable Inlet Holes at the EC40CE Cabinet Bottom

Figure 4-31 EC40CE Cabinet Structure

All Rights reserved, No Spreading abroad without Permission of ZTE 74


ZTE Low Level Design for MSAG Upgrade Project

5 Network Reliability

5.1 C300M Equipment protection

 Providing 1+1 protection of the main control & switching unit, backplane bus and uplink card;

 Rack and shelf provide 1+1 protection of dual power supplies;

 Providing N+1 protection of fan units.

5.2 C300M Link Aggregation protection

Definition of Link Aggregation

All Rights reserved, No Spreading abroad without Permission of ZTE 75


ZTE Low Level Design for MSAG Upgrade Project

 Link aggregation, also called trunking, binds multiple physical ports of the MSAG into a logic port. Link
aggregation is used to balance load of outgoing/incoming traffic among these ports. The maximum
port number is 4 in one link aggregation group. In this project the port number is 2 in one link
aggregation group. The total bandwidth is 2*GE. There are two free GE optical ports for the future
expansion.

 At the same time, it provides backup. When some link is faulty, other uplink interfaces can work
normally to ensure the continuity of services. The load sharing adopts the algorithm based on L2 MAC
address, which evenly distributes service traffics to several links.

 When any link is interrupted (signal interruption on the physical layer, such as broken optical fibers,
broken cables, damaged optical module and so on), the interrupted services on the interrupted link are
immediately switched over to another link to minimize the service interruption. After the interrupted link
recovers, the services on the original link automatically judge and readopt the load sharing mode.

 The link aggregation not only provides a link protection function that's impossible in the single link
condition, but also evenly distributes services on different links to provide wider physical channels for
the service bearings.

Figure 5-32 Link Aggregation Protection Mode

Uplink Network

Aggregation

Link Aggregation Protection Mode

Rules of Link Aggregation Protection Configuration

All Rights reserved, No Spreading abroad without Permission of ZTE 76


ZTE Low Level Design for MSAG Upgrade Project

 Support two link aggregation modes: static Trunk and LACP. Static trunk directly adds multiple
physical ports to a trunk group, thus forming a logical port. The realization of this mode is rather
simple, but it is not suitable for observing the status of the link aggregation port. LACP (Link
Aggregation Control Protocol) is link aggregation control protocol, which follows IEEE 802.3ad
standard.

 LACP converges multiple physical ports into a trunk group to form a logical port and automatically
generates aggregation to obtain the maximum bandwidth.

 At most eight Trunk groups can be configured, and each trunk group has at most eight member ports;

 It supports cross-interface card aggregation, and member ports can be distributed on any interface
card, but member ports selected must operate in full duplex mode, with the consistent rate.

 Member port modes must be consistent, such as access, trunk, or hybrid;

 The logical port formed by link aggregation on the ZXA10 C300M is called a smartgroup. A
smartgroup can be used as a common port, and has the same default VLAN attributes as the common
Ethernet ports;

 Configure the load-balance mode of link aggregation group: ZXA10 C300M supports two types of
load-balance: based on the source IP, and based on the source MAC. The default mode is based on
the source MAC addresses.

5.3 C300M MSTP protection

 Produce a single spanning tree active topology for any given VLAN, ensuring that there is only
one data path between any two end stations for frames associated to said VLAN. Frames for
different VLANs may follow different paths.

 Provide fault tolerance by automatically reconfiguring topology after Bridge or data path failures.

 Achieve stable topology in minimal amount of time.

 Operate transparent to end stations.

 Minimal required memory requirements and device configuration.

All Rights reserved, No Spreading abroad without Permission of ZTE 77


ZTE Low Level Design for MSAG Upgrade Project

Eliminates the need for having a separate RSTP spanning tree for each VLAN.

Saves processing and memory consumption on the device.

 Much easier control when a large number of VLANs are used.

 The design of the multiple spanning tree protocol is based on RSTP and extended to allow for
different VLANs to travel along separate “instances” of spanning tree while allowing compatibility
with legacy STP devices.

 bridge priorities may be different depending on the instance, frames may travel a different paths
in the active topology depending on what instance they are assigned to.

 The following operations are implemented by exchanging BPDU messages:

Selects a root bridge in a stable spanning tree topology.

Specifies a switch in each switch network segment.

Configures the state of redundant switch ports as "Discard" to avoid loops formed in the
network.

 ZXA10 C300M STP supports the following three modes:

SSTP

SSTP complies with the IEEE802.1d standard. The bridge running SSTP can interwork
with the bridges running RSTP and MSTP.

RSTP

RSTP converges faster than SSTP. When a topology changes, the state of a configured
redundant switch port transits rapidly in the point-to-point connection.

MSTP

MSTP provides the concepts of instances and VLAN mapping, and supports rapid VLAN
convergence and load balance. MSTP supports multiple spanning-tree instances and
different forwarding states of a port in different VLANs. It allows formation of multiple
independent sub-tree instances within an MST area for load balance.

All Rights reserved, No Spreading abroad without Permission of ZTE 78


ZTE Low Level Design for MSAG Upgrade Project

6 NMS U31 Solution

6.1 Overview

NetNumen U31 is the integrated network management system developed by ZTE and is also the
future-oriented network management product and solution. It improves the capability, scalability
and ease of use with the mature and advanced network management architecture. It is a highly
customer-friendly, carrier-class and cross-platform integrated network management system.

All Rights reserved, No Spreading abroad without Permission of ZTE 79


ZTE Low Level Design for MSAG Upgrade Project

Figure 6-33 NMS U31 System Architecture

NetNumen U31 provides centralized management and monitoring over network elements, helping

the operators to know the actual status of the network, adjust the equipment conveniently, and
make the network in its best status.

NetNumen U31 system adopts client/server architecture. The server software provides northbound
interfaces for BOSS/NMS, while southbound interfaces for NEs. The client software provides graphical
user interfaces to operate and maintain NEs.

For each site we deploy one IBM V5020 Disk Array, one Dell R740 Linux server and one KVM. Server
in Old airport is master. Server in Kirkos is backup one.

6.2 System Characteristics

 The EMS system should be able to quickly recover from disasters. When the active site fails to
function properly due to earthquakes, floods or snow disasters, the standby site should be able to

All Rights reserved, No Spreading abroad without Permission of ZTE 80


ZTE Low Level Design for MSAG Upgrade Project

take over the charge of all the operations and continue the uninterrupted service to subscribers.

 The active site should be far away from the standby sites so that the mentioned disasters cannot
affect both of the sites at the same time.

6.3 Solution Introduction

It is implemented by deploying the active EMS system, HA fault-tolerant software, and the standby
EMS system. Generally, O&M personnel can perform the remote backup and restore operations
from a subordinate network O&M center. Compared with local two-server redundancy, the remote
1+1 redundancy solution has two characteristics:

 The active and standby sites are monitored by third-party products so that when one fails,
applications on it can be switched over to the other immediately.

 Third-party products are used to implement remote data replication between the active and
standby sites.

Figure 6-34 HA – Remote Disaster Recovery System Architecture

Before the occurrence of failure, two EMS systems A and B have the same capabilities on which all

All Rights reserved, No Spreading abroad without Permission of ZTE 81


ZTE Low Level Design for MSAG Upgrade Project

EMS applications and databases have been installed. But only A which is active to provide the
management service. If A fails to function properly due to disasters, B will takes over the charge as
the active site and continues the delivery of the services.

6.4 Software Deployment

To supervise the condition of EMS servers and enable data replication and switchover between
them, we need to install a HA software system. The software configuration for a remote 1+1
redundant system is shown below:

Table 6-49 Software Deployment for Remote 1+1 Redundant System (Server-based)

Software Position Purpose

Third-party products Active server Condition detection,


(VCS+ VVR+ GCO) switchover and data
replication

Third-party products Standby server Condition detection,


(VCS+ VVR+ GCO) switchover and data
replication

Database system Active server Operating environment for


EMS databases

Database system Standby server Operating environment for


EMS databases

NetNumen EMS Disk array (active


applications server)

NetNumen EMS Disk array


applications (standby server)

All Rights reserved, No Spreading abroad without Permission of ZTE 82


ZTE Low Level Design for MSAG Upgrade Project

7 Service Deployment

7.1 VOIP Service

ZXA10 C300M supports voice services in NGN/IMS based on H.248 and SIP, including
POTS/ISDN voice, FAX, MODEM, PBX, and various supplementary services. From the view of
voice service, ZXA10 C300M acts as an AG (Access Gateway) in NGN/IMS.

Figure 7-35 VOIP service traffic module

All Rights reserved, No Spreading abroad without Permission of ZTE 83


ZTE Low Level Design for MSAG Upgrade Project

When deployed in the softswitch based NGN, the ZXA10 C300M/C350M will be under the control
of the softswitch through H.248 or SIP protocol. When deployed in IMS, the ZXA10 C300M will be
under the control of the P-CSCF through SIP protocol or under the control of the AGCF through
H.248 or SIP protocol. In NGN/IMS, the ZXA10 C300M is acting as an AG to support various voice
related services, such as VoIP (voice over IP), FoIP (FAX over IP), MoIP (MODEM over IP),
through various subscriber interfaces ,such as POTS, ISDN BRA, and ISDN PRA.

7.2 Broadband Service

ZXA10 C300M supports broadband access services based on copper, such as ADSL/2/2+, VDSL2, and
SHDSL.bis, with enhanced DSL features, to provide users with various broadband services such as
High Speed Internet (HSI) and video service.

Figure 7-36 Broadband service traffic module

All Rights reserved, No Spreading abroad without Permission of ZTE 84


ZTE Low Level Design for MSAG Upgrade Project

The dial-up data of the users are transmitted transparently to the BRAS equipment via MSAG, or GPON
network, the BRAS sends the relevant authentication information and billing information to the AAA
server, after the authentication is passed, the BRAS allocated IP addresses for the users.

The STB of the IPTV user gets the IP address via DHCP or PPPoE, whether the request of On Demand
programs needs the authentication of the AAA server. After the user information authentication has
passed, IPTV platform forwards corresponding multicast flows to corresponding MSAG, or GPON
network.

7.3 GPON Service


As one of PON technologies, the GPON is developed based on a Gigabit PON complying with the ITU-T
G.984.x recommendations. A GPON system consists of OLTs in offices, ONU/ONTs in clients and ODNs.
It uses a point-to-point network architecture, satisfying the high requirements of broadband subscribers.

ZXA10 C300M GPON card supports up to 16 GPON interfaces. A single shelf supports up to 128 GPON
interfaces, supports a split ratio of 1:128 and can be connected with up to 16384 ONUs.

All Rights reserved, No Spreading abroad without Permission of ZTE 85


ZTE Low Level Design for MSAG Upgrade Project

Figure 7-37 GPON service traffic module

8 DATA planning

8.1 Detail IP,VLAN and port planning

Table 8-50 EMS Port planning

site type IP node EMS Port CS port

All Rights reserved, No Spreading abroad without Permission of ZTE 86


ZTE Low Level Design for MSAG Upgrade Project

EMS
Server 111128-OA-CS-A em1 Gei-0/7/0/39

Old EMS
Gei-0/7/0/40
airport Server 111128-OA-CS-A em2

EMS
Gei-0/7/0/41
Server 111128-OA-CS-A em3

EMS
Gei-0/7/0/42
Server 111168-KK-CS-B em1

EMS
Gei-0/7/0/46
Kirkos Server 111168-KK-CS-B em2

EMS
Gei-0/7/0/47
Server 111168-KK-CS-B em3

Table 8-51 EMS IP address/Vlan planning

site type IP address Mask Gateway NIC Fix/Float Remark Vlan

EMS 255.25 PE-A


Serve 10.204.204.193 5.255. 10.204.2 Em1 3760
r 248 04.196 Fix Host ip

Old EMS 255.25 PE-B


Cluster
airpor Serve 10.204.204.194 5.255. 10.204.2 Em2 Float 3760
ip
t r 248 04.197

EMS 255.25 VRRP


Heartbe
Serve 10.204.204.195 5.255. 10.204.2 Em3 Float 3760
at ip
r 248 04.198

Kirko EMS 255.25 PE-A


s Serve 10.204.204.201 5.255. 10.204.2 Em1 Fix Host ip 3760
r 248 04.204

EMS 10.204.204.202 255.25 PE-B Em2 Float Cluster 3760


Serve 5.255. 10.204.2 ip
r 248 04.205

All Rights reserved, No Spreading abroad without Permission of ZTE 87


ZTE Low Level Design for MSAG Upgrade Project

EMS 255.25
Heartbe
Serve 10.204.204.203 5.255. Em3 Float 3760
VRRP at ip
r 248
10.204.2

Table 8-52 iENERGY IP address/Port planning

Server MGMT Netmas Gatewa


site type IP node CS port Vlan
Port IP k y

PE-A
10.204.2
04.36

Old iENE PE-B


111128- Gei- 10.204.2 255.255.
airpor RG em1 10.204.2 3761
OA-CS-A 0/7/0/42 04.33 255.248
t Y 04.37

VRRP
10.204.2
04.38

Table 8-53 MSAG uplink CS devices port planning

Rin
Site uplink CS device CS port
g

New MSAG_306 111082-YK-CS-A xgei-0/2/0/2


1
New MSAG_321 111082-YK-CS-B xgei-0/2/0/2

New MSAG_808 111136-BL-CS-A xgei-0/2/0/2


2
New MSAG_806 111136-BL-CS-B xgei-0/2/0/2

New MSAG_789 111058-LGH-CS-A xgei-0/2/0/4


3
New MSAG_730 111058-LGH-CS-B xgei-0/2/0/4

All Rights reserved, No Spreading abroad without Permission of ZTE 88


ZTE Low Level Design for MSAG Upgrade Project

New MSAG_793 111058-LGH-CS-A xgei-0/2/0/5


4
New MSAG_720 111058-LGH-CS-B xgei-0/2/0/5

New MSAG_870 111136-BL-CS-A xgei-0/2/0/6


5
New MSAG_855 111136-BL-CS-B xgei-0/2/0/6

111010_Bole_Mch
GigabitEthernet8/0/3
ael_ASG_A
6 New MSAG_839
111010_Bole_Mch
GigabitEthernet8/0/3
ael_ASG_B

New MSAG_202 111007-NS-CS-A xgei-0/2/0/3


7
New MSAG_221 111007-NS-CS-B xgei-0/2/0/3

111767_Kality_AS
New MSAG_2301 GigabitEthernet8/2/0
G_A
8
111408_Akaki_AS
New MSAG_14 GigabitEthernet8/0/2
G_A

111057_Addis_Ket
GigabitEthernet8/2/1
ema_ASG_A
9 New MSAG_630
111057_Addis_Ket
GigabitEthernet8/2/1
ema_ASG_B

111055-AD-CS-A xgei-0/2/0/4
10 New MSAG_485
111055-AD-CS-B xgei-0/2/0/4

111165_Ayat_ASG
New MSAG_2504 GigabitEthernet8/0/4
_A
11
111086_Kotebe_A
New MSAG_1639 GigabitEthernet8/0/4
SG_A

111120_Hanamari
GigabitEthernet8/2/0
am_ASG_A
12 New MSAG_1913
111120_Hanamari
GigabitEthernet8/2/0
am_ASG_B

All Rights reserved, No Spreading abroad without Permission of ZTE 89


ZTE Low Level Design for MSAG Upgrade Project

111089_Gerji_AS
GigabitEthernet8/0/4
G_A
13 New MSAG_1102
111089_Gerji_AS
GigabitEthernet8/0/4
G_B

14 New MSAG_469 111055-AD-CS-A xgei-0/2/0/5

New MSAG_490 111055-AD-CS-B xgei-0/2/0/5

Table 8-54 Detail IP Address and VLAN Assignment of C300M

VOI
BB MGMT
Ri P MGMT IP MGMT IP of MGMT &
site SVLA VLAN of VOIP IP VOIP GW
ng VLA of C300M ZXDU68 B301 DU GW
N C300M
N

New 10.109. vrf FL vrf OAM


229 10.109.23 10.109.232.4
MSAG_30 2405 2299 234.17/ 10.109.234. 10.109.23
8 2.33/27 1/27
6 28 30 2.62

New 10.109. vrf FL vrf OAM


229 10.109.23 10.109.232.4
MSAG_32 2406 2299 234.18/ 10.109.234. 10.109.23
8 2.34/27 2/27
6 28 30 2.62

New 10.109. vrf FL vrf OAM


229 10.109.23 10.109.232.4
1 MSAG_33 2407 2299 234.19/ 10.109.234. 10.109.23
8 2.35/27 3/27
0 28 30 2.62

New 10.109. vrf FL vrf OAM


229 10.109.23 10.109.232.4
MSAG_32 2408 2299 234.20/ 10.109.234. 10.109.23
8 2.36/27 4/27
2 28 30 2.62

New 10.109. vrf FL vrf OAM


229 10.109.23 10.109.232.4
MSAG_32 2409 2299 234.21/ 10.109.234. 10.109.23
8 2.37/27 5/27
1 28 30 2.62

2 New 2590 229 2299 10.109. 10.109.23 10.109.232.1 vrf FL vrf OAM
MSAG_80 234.1/2

All Rights reserved, No Spreading abroad without Permission of ZTE 90


ZTE Low Level Design for MSAG Upgrade Project

10.109.234. 10.109.23
8 8 8 2.1/27 1/27
14 2.30

New 10.109. vrf FL vrf OAM


229 10.109.23 10.109.232.1
MSAG_81 2591 2299 234.2/2 10.109.234. 10.109.23
8 2.2/27 2/27
2 8 14 2.30

New 10.109. vrf FL vrf OAM


229 10.109.23 10.109.232.1
MSAG_83 2592 2299 234.3/2 10.109.234. 10.109.23
8 2.3/27 3/27
0 8 14 2.30

New 10.109. vrf FL vrf OAM


229 10.109.23 10.109.232.1
MSAG_81 2593 2299 234.4/2 10.109.234. 10.109.23
8 2.4/27 4/27
7 8 14 2.30

New 10.109. vrf FL vrf OAM


229 10.109.23 10.109.232.1
MSAG_80 2594 2299 234.5/2 10.109.234. 10.109.23
8 2.5/27 5/27
6 8 14 2.30

10.109. vrf FL vrf OAM


New 229 10.109.23 10.109.232.7
MSAG_78 2787 2299 234.33/ 10.109.234. 10.109.23
8 2.65/27 5/27
9 28 46 2.94

10.109. vrf FL vrf OAM


New 229 10.109.23 10.109.232.7
MSAG_74 2788 2299 234.34/ 10.109.234. 10.109.23
8 2.66/27 6/27
3 28 46 2.94

10.109. vrf FL vrf OAM


New 229 10.109.23 10.109.232.7
3 MSAG_79 2789 2299 234.35/ 10.109.234. 10.109.23
8 2.67/27 7/27
4 28 46 2.94

10.109. vrf FL vrf OAM


New 229 10.109.23 10.109.232.7
MSAG_73 2790 2299 234.36/ 10.109.234. 10.109.23
8 2.68/27 8/27
7 28 46 2.94

10.109. vrf FL vrf OAM


New 229 10.109.23 10.109.232.7
MSAG_73 2791 2299 234.37/ 10.109.234. 10.109.23
8 2.69/27 9/27
0 28 46 2.94

All Rights reserved, No Spreading abroad without Permission of ZTE 91


ZTE Low Level Design for MSAG Upgrade Project

10.109. vrf FL vrf OAM


New 229 10.109.23 10.109.232.1
MSAG_79 2592 2297 234.49/ 10.109.234. 10.109.23
6 2.97/27 06/27
3 28 62 2.126

10.109. vrf FL vrf OAM


New 229 10.109.23 10.109.232.1
MSAG_72 2593 2297 234.50/ 10.109.234. 10.109.23
6 2.98/27 07/27
9 28 62 2.126
4
10.109. vrf FL vrf OAM
New 229 10.109.23 10.109.232.1
MSAG_72 2594 2297 234.51/ 10.109.234. 10.109.23
6 2.99/27 08/27
7 28 62 2.126

10.109. vrf FL vrf OAM


New 229 10.109.23 10.109.232.1
MSAG_72 2595 2297 234.52/ 10.109.234. 10.109.23
6 2.100/27 09/27
0 28 62 2.126

10.109. vrf FL vrf OAM


New 229 10.109.23 10.109.232.1
MSAG_87 2595 2297 234.65/ 10.109.234. 10.109.23
6 2.129/27 38/27
0 28 78 2.158

10.109. vrf FL vrf OAM


New 229 10.109.23 10.109.232.1
MSAG_80 2596 2297 234.66/ 10.109.234. 10.109.23
6 2.130/27 39/27
4 28 78 2.158
5
10.109. vrf FL vrf OAM
New 229 10.109.23 10.109.232.1
MSAG_80 2597 2297 234.67/ 10.109.234. 10.109.23
6 2.131/27 40/27
5 28 78 2.158

10.109. vrf FL vrf OAM


New 229 10.109.23 10.109.232.1
MSAG_85 2598 2297 234.68/ 10.109.234. 10.109.23
6 2.132/27 41/27
5 28 78 2.158

New 10.109. vrf FL vrf OAM


229 10.109.23 10.109.232.2
6 MSAG_83 2600 2291 234.81/ 10.109.234. 10.109.23
0 2.225/28 30/28
9 28 94 2.238

7 New 2391 229 2299 10.109. 10.109.23 10.109.232.1 vrf FL vrf OAM
MSAG_20 8 234.97/ 2.161/27 70/27
10.109.234. 10.109.23
2 28

All Rights reserved, No Spreading abroad without Permission of ZTE 92


ZTE Low Level Design for MSAG Upgrade Project

110 2.190

10.109. vrf FL vrf OAM


New 229 10.109.23 10.109.232.1
MSAG_20 2392 2299 234.98/ 10.109.234. 10.109.23
8 2.162/27 71/27
1 28 110 2.190

10.109. vrf FL vrf OAM


New 229 10.109.23 10.109.232.1
MSAG_20 2393 2299 234.99/ 10.109.234. 10.109.23
8 2.163/27 72/27
3 28 110 2.190

10.109. vrf FL vrf OAM


New 229 10.109.23 10.109.232.1
MSAG_22 2394 2299 234.100 10.109.234. 10.109.23
8 2.164/27 73/27
2 /28 110 2.190

10.109. vrf FL vrf OAM


New 229 10.109.23 10.109.232.1
MSAG_22 2395 2299 234.101 10.109.234. 10.109.23
8 2.165/27 74/27
1 /28 110 2.190

10.109. vrf FL vrf OAM


New 229 10.109.23 10.109.232.2
MSAG_23 2396 2297 234.113 10.109.234. 10.109.23
6 2.193/27 02/27
01 /28 126 2.222

10.109. vrf FL vrf OAM


New 229 10.109.23 10.109.232.2
MSAG_23 2397 2297 234.114 10.109.234. 10.109.23
6 2.194/27 03/27
09 /28 126 2.222
8
10.109. vrf FL vrf OAM
New 229 10.109.23 10.109.232.2
MSAG_23 2398 2297 234.115 10.109.234. 10.109.23
6 2.195/27 04/27
07 /28 126 2.222

10.109. vrf FL vrf OAM


229 10.109.23 10.109.232.2
New 2399 2297 234.116 10.109.234. 10.109.23
6 2.196/27 05/27
MSAG_14 /28 126 2.222

New 10.109. vrf FL vrf OAM


229 10.109.23 10.109.232.2
9 MSAG_63 2400 2299 234.129 10.109.234. 10.109.23
8 2.241/28 45/28
0 /28 142 2.254

10 New 2691 229 2297 10.109. 10.109.23 10.109.233.8 vrf FL vrf OAM

All Rights reserved, No Spreading abroad without Permission of ZTE 93


MGM
Rin BB VOIP
site T
g SVLAN VLAN
VLAN

MSAG_306 2615 3180 3630

MSAG_330 2609 ZTE 3204


Low Level3654
Design for MSAG Upgrade Project

1 MSAG_326 2607 3200 3650

MSAG_48 MSAG_32234.145
2 2611 3196 3646 10.109.234. 10.109.23
5 3.1/28 /28
5 MSAG_321 /28 2667 3195 3645 158 3.14

MSAG_808
10.109. 2529 3123 3621 vrf FL vrf OAM
New 229 10.109.23 10.109.233.2
MSAG_25 2410 2297
MSAG_8 234.161 2539
12 3125 3627 10.109.234. 10.109.23
6 3.17/28 4/28
04 2 MSAG_830 /28 2511 3133 3622 174 3.30

MSAG_817 2503 3128 3625 vrf FL vrf OAM


New 10.109.
229 MSAG_8 06 10.109.233122
2533 10.109.233.2
3640
11 MSAG_16 2411 2297 234.162 10.109.234. 10.109.23
6 3.18/28 5/28
40 MSAG_789 /28 2593 3194 3699 174 3.30
MSAG_743 2547 2300 3613
10.109. vrf FL vrf OAM
New 3229 MSAG_794 2595
10.109.233199 3689
10.109.233.2
MSAG_16 2412 2297 234.163 10.109.234. 10.109.23
6 MSAG_737 3.19/28 3121
2459 6/28
3621
39 /28 174 3.30
MSAG_730 2527 3138 3638
10.109. 2597 vrf FL vrf OAM
New MSAG_793 3198 3690
229 10.109.23 10.109.233.3
12 MSAG_19 2400 2295 234.177 2605
MSAG_729 10.109.234. 10.109.23
4 3.33/28 3187 3694
8/28
4 /28
13 MSAG_727 2639 3186 3692 190 3.46

MSAG_720
10.109. 2499 3107 3607 vrf FL vrf OAM
New 229 10.109.23 10.109.233.5
13 MSAG_11 2601 2293 234.193 2427
MSAG_870 3102 3602 10.109.234. 10.109.23
2 3.49/28 5/28
02 MSAG_804 /28 2499 3120 3634 206 3.62
5
MSAG_805 2435 3121 3619 vrf FL vrf OAM
New 10.109.
229 10.109.233136
10.109.233.7
MSAG_46 2689 2296 234.209 2497
MSAG_855 3620
10.109.234. 10.109.23
4 3.65/28 2/28
9 6 MSAG_839 /28 2721 3207 3601 222 3.78
14
MSAG_202 2613 3101 3607
10.109. vrf FL vrf OAM
New 229 10.109.233100
10.109.233.7
MSAG_201 2611 3606
MSAG_49 2690 2296 234.210 10.109.234. 10.109.23
74 MSAG_203 /28 3.66/28 3102 3/28
2557 3608
0 222 3.78
MSAG_222 2603 3119 3625

MSAG_221 2601 3118 3624

MSAG_2301 2647 3194 3635

MSAG_2309 2529 3202 3643


8
Table 8-55 Detail VLAN
MSAG_2307 2535 3200 3641
Assignment of Old
MSAG_14 2683 3162 3659
MSAG 5200
9 MSAG_630 2483 3109 3618
10 MSAG_485 2443 3100 3611

MSAG_2504 2533 3144 3603


11 MSAG_1640 2781 3140 3715
All Rights reserved, No Spreading abroad without Permission of ZTE 94
MSAG_1639 2779 3139 3714
12 MSAG_1913 2483 3187 3686
13
ZTE Low Level Design for MSAG Upgrade Project

8.2 Equipment & interface naming convention


Equipment naming convention:

[region]-[city]-[zone or town]-[site name]-[site ID]-[vendor]-[equipment type]

For example:

The site is MSAG-0330. The equipment name should be Addis-CAAZ-0330-C300M

8.3 Configuration script

8.3.1 C300M(Enhanced MSAG 306 as sample)

ZXAN#configure terminal

ZXAN(config)#add-rack rackno 1 racktype IEC19

ZXAN(config)#add-shelf shelfno 1 shelftype IEC_SHELF

ZXAN(config)#set-pnp enable

ZXAN(config)#del-subcard shelfno 1 slotno 10 subcardno 1

ZXAN(config)#add-subcard shelfno 1 slotno 10 subcardno 1 voip

ZXAN(config)#vlan 2405,2298,2299-2301,2615,3180,3310,3630

ZXAN(config-vlan)#exit

ZXAN(config)#interface xgei_1/19/1

ZXAN(config-if)#switchport vlan 2405,2298,2299-2301,2615,3180,3310,3630 tag

ZXAN(config)#interface xgei_1/20/1

ZXAN(config-if)#switchport vlan 2405,2298,2299-2301,2615,3180,3310,3630 tag

All Rights reserved, No Spreading abroad without Permission of ZTE 95


ZTE Low Level Design for MSAG Upgrade Project

ZXAN(config-if)#exit

ZXAN(config)#interface vlan 2299

ZXAN(config-if-vlan100)#ip address 10.109.232.2 255.255.255.192

ZXAN(config-if-vlan100)#exit

ZXAN(config)#snmp-server host 10.204.204.193 version 2c public enable NOTIFICATIONS target-addr-


name zte isnmsserver udp-port 162

ZXAN(config)#spanning-tree enable

ZXAN(config)#spanning-tree mode mstp

ZXAN(config)#spanning-tree mst configuration

ZXAN(config-mstp)#revision 10

ZXAN(config-mstp)#name MSAG_Ring01

ZXAN(config-mstp)#instance 2 vlans 2405,2298,2299-2301,2615,3180,3310,3630

ZXAN(config-mstp)#exit

ZXAN(config)#spanning-tree mst instance 2 priority 256

ZXAN(config)#interface gei_1/19/3

ZXAN(config-if)#switchport vlan 2300-2301,2615,3180,3310,3630 tag

ZXAN(config)#interface gei_1/20/3

ZXAN(config-if)#switchport vlan 2300-2301,2615,3180,3310,3630 tag

ZXAN(config)#interface smartgroup1

ZXAN(config-smartgroup1)#smartgroup load-balance src-dst-mac

ZXAN(config-smartgroup1)#switchport vlan 2300-2301,2615,3180,3310,3630 tag

ZXAN(config)#interface gei_1/19/3

ZXAN(config-if)#smartgroup 1 mode active

ZXAN(config)#interface gei_1/20/3

ZXAN(config-if)#smartgroup 1 mode active

All Rights reserved, No Spreading abroad without Permission of ZTE 96


ZTE Low Level Design for MSAG Upgrade Project

ZXAN(config-if)#lacp timeout long

ZXAN#write

8.3.2 5200 V3(Old MSAG-306 as sample)

ZXAN#configure terminal

ZXAN(config)#

ZXAN(config)#add-rack rackno 1 racktype MSAG

ZXAN(config)#add-shelf rackno 1 shelfno 1 shelftype MESL_CTL

ZXAN(config)#add-shelf rackno 1 shelfno 2 shelftype MESL_EX connectid 1

ZXAN(config)#add-shelf rackno 1 shelfno 3 shelftype MESL_EX connectid 2

ZXAN(config)#add-shelf rackno 1 shelfno 4 shelftype MESL_EX connectid 3

ZXAN(config)#add-shelf rackno 1 shelfno 5 shelftype MESL_EX connectid 4

ZXAN(config)#add-card rackno 1 shelfno 1 slotno 3 GILCA

ZXAN(config)#add-card rackno 1 shelfno 1 slotno 4 EPOI

ZXAN(config)#add-card rackno 1 shelfno 1 slotno 5 ALC

ZXAN(config)#add-card rackno 1 shelfno 1 slotno 6 DTI

ZXAN(config)#add-subcard rackno 1 shelfno 1 slotno 9 subcardno 1 GEI_B

ZXAN(config)#vlan 2300-2301,2615,3180,3310,3630

ZXAN(config-vlan)#exit

ZXAN(config)#interface vlan 3630

ZXAN(config-if)#ip address 10.109.198.244 255.255.255.0

ZXAN(config-if)#exit

ZXAN(config)#interface gei_1/9/1

ZXAN(config-if)#switchport 2300-2301,2615,3180,3310,3630 tag

ZXAN(config-if)#exit

ZXAN(config)#interface gei_1/9/2

ZXAN(config-if)#switchport 2300-2301,2615,3180,3310,3630 tag

All Rights reserved, No Spreading abroad without Permission of ZTE 97


ZTE Low Level Design for MSAG Upgrade Project

ZXAN(config-if)#exit

ZXAN(config)#interface smartgroup1

ZXAN(config-if)#smartgroup load-balance src-ip

ZXAN(config-if)#exit

ZXAN(config)#interface gei_1/9/1-2

ZXAN(config-if-range)#smartgroup 1 mode on

ZXAN(config-if)#exit

ZXAN(config)#interface smartgroup1

ZXAN(config-if)#switchport mode trunk

ZXAN(config-if)#switchport vlan 2300-2301,2615,3180,3310,3630 tag

ZXAN(config-if)#end

ZXAN(config)#vlan 1000-1200

ZXAN(config-vlan)#exit

ZXAN(config)#interface adsl_1/3/1-16

ZXAN(config-if-range)#switchport mode access

ZXAN(config-if-range)#switchport default cvlan 1000-1200 one-to-one pvc 1

ZXAN(config-if-range)#switchport default vlan 2615 one-to-one pvc 1

ZXAN(config-if-range)#exit

ZXAN(config)#adsl profile 8Mprofile

This profile does not exist. Would you like to create? [y/n][y]y ZXAN(config)#adsl profile 2Mprofile

AtucConfRateMode(1-fixed,2-adaptAtStartup,3-adaptAtRuntime):[2] AtucConfRateChanRatio(0..100%):[0]
AtucConfTargetSnrMgn(0..310(0.1dB)):[80] AtucConfMaxSnrMgn(80..310(0.1dB)):[310]
AtucConfMinSnrMgn(0..80(0.1dB)):[0] AtucConfDownshiftSnrMgn(0(0.1dB)):[0]
AtucConfUpshiftSnrMgn(0(0.1dB)):[0] AtucConfMinUpshiftTime(0..16383s):[0]
AtucConfMinDownshiftTime(0..16383s):[0] ConfProfileLineType(1-fast-only,2-interleaved-only):[2]
AtucChanConfFastMaxTxRate(0..131040kbps):[1024] AtucChanConfFastMinTxRate(0..1024kbps):[32]
AtucChanConfInterleaveMaxTxRate(0..131040kbps):[1024]2048

All Rights reserved, No Spreading abroad without Permission of ZTE 98


ZTE Low Level Design for MSAG Upgrade Project

AtucChanConfInterleaveMinTxRate(0..1024kbps):[32] AtucChanConfMaxInterleaveDelay(0..255ms):[16]
AturConfRateMode(1-fixed,2-adaptAtStartup,3-adaptAtRuntime):[2] AturConfRateChanRatio(0..100%):[0]
AturConfTargetSnrMgn(0..310(0.1dB)):[80] AturConfMaxSnrMgn(80..310(0.1dB)):[310]
AturConfMinSnrMgn(0..80(0.1dB)):[0] AturConfDownshiftSnrMgn(0(0.1dB)):[0]
AturConfUpshiftSnrMgn(0(0.1dB)):[0] AturConfMinUpshiftTime(0..16383s):[0]
AturConfMinDownshiftTime(0..16383s):[0] AturChanConfFastMaxTxRate(0..10240kbps):[512]
AturChanConfFastMinTxRate(0..512kbps):[32] AturChanConfInterleaveMaxTxRate(0..10240kbps):[512]
AturChanConfInterleaveMinTxRate(0..512kbps):[32] AturChanConfMaxInterleaveDelay(0..255ms):[16]
AtucDMTConfFreqBinsOperType(1-open,2-cancel):[2] AturDMTConfFreqBinsOperType(1-open,2-cancel):
[2] LineDMTConfEOC(1-byte ,2-streaming ):[1]

LineDMTConfTrellis(1-on,2-off):[1] AtucConfMaxBitsPerBin(0..15):[15] AtucConfUseCustomBins(1-on,2-


off):[2] AtucConfDnBitSwap(1-on,2-off):[2] AtucConfUpBitSwap(1-on,2-off):[2]
AtucConfREADSL2Enable(1-on,2-off):[2] AtucConfPsdMaskType(1-DMT_PSD_MSK,2-
ADSL2_PSD_MSK,3-ADSL2_READSL_WIDE_PSD_MSK,4- ADSL2_READSL_NARROW_PSD_MSK):
[3] AtucConfPMMode(1-DISABLE,2-L3_ENABLE,3-L2_ENABLE,4-L3_ENABLE|L2_ENABLE):[1]
AtucConfPML0Time(0..255s):[240] AtucConfPML2Time(0..255s):[120] AtucConfPML2ATPR(0..31db):[3]
AtucConfPML2Rate(512..1024kbps):[512] AtucConfMinInp(0-INP_AUTO,1-INP_0,2-INP_POINT5,3-
INP_1,4-INP_2,5-INP_4,6-INP_8,7 -INP_16):[2] AturConfMinInp(0-INP_AUTO,1-INP_0,2-INP_POINT5,3-
INP_1,4-INP_2,5-INP_4,6-INP_8,7 -INP_16):[2]

ZXAN(config)#interface adsl_1/3/1-16

ZXAN(config-if-range)#adsl profile 8Mprofile

ZXAN#configure terminal

ZXAN(config)#vlan 1401

ZXAN(config-vlan)#exit

ZXAN(config)#interface gei_1/9/1

ZXAN(config-if)#no shutdown

ZXAN(config-if)#switchport mode hybrid

ZXAN(config-if)#switchport vlan 1401 tag

ZXAN(config-if)#exit

ZXAN(config)#show onu unauthentication epon-olt_1/4/1

Onu Interface : epon-onu_1/8/1:1

Onu Model : ZTE-D422

All Rights reserved, No Spreading abroad without Permission of ZTE 99


ZTE Low Level Design for MSAG Upgrade Project

MAC Address : 0019.c600.0011

SN : 0019c6000011

LOID : 0019c6000011

Online State : authentication deny

ExtOam State : complete

Software Version : V1.1.0P2

Hardware Version : D422V1

RegTime : 2012/06/20 01:26:33

ZXAN(config)#interface epon-olt_1/4/1

ZXAN(config-if)#onu 1 type ZTE-D422 mac 0019.c600.0011

ZXAN(config-if)#exit

ZXAN(config)#interface epon-onu_1/4/1:1

ZXAN(config-if)#sla upstream assured 5120 maximum 10240

ZXAN(config-if)#sla downstream maximum 10240

ZXAN(config-if)#switchport mode trunk

ZXAN(config-if)#switchport vlan 1401 tag

ZXAN(config-if)#exit

ZXAN(config)#pon-onu-mng epon-onu_1/8/1:1

ZXAN(epon-onu-mng)#vlan port eth_0/1 mode tag vlan 1401 priority 0

ZXAN(epon-onu-mng)#end

ZXAN#configure terminal

ZXAN(config)#msag

ZXAN(config-msag)#mgc add 1 10.208.0.4 port 2944 type 1

ZXAN(config-msag)#mg add 1 1 port 2944

ZXAN(config-msag)#voip interface add ctrl-ip 10.109.30.132 ctrl-mask

All Rights reserved, No Spreading abroad without Permission of ZTE 100


ZTE Low Level Design for MSAG Upgrade Project

255.255.255.248 media-ip 10.109.30.132 media-mask 255.255.255.248 mgid 1

ZXAN(config-msag)#voip route add 10.109.30.132 mgid 1

ZXAN(config-msag)#rtp terminationid add RTP 240 mgid 1 type 2 begin-no 0

ZXAN(config-msag)#slc terminationid add rack 1 shelf 1 5 begin-index 1

num 32 USER digit-length 3 begin-no 0 type 3 mgid 1

ZXAN(config-msag)#media-nat add 11 1 9 5 5 10.31.1.2 12000

ZXAN(config-msag)#media-nat add 12 1 9 5 5 10.31.1.2 14000

ZXAN(config-msag)#exit

ZXAN(config)#vlan 3180

ZXAN(config-vlan)#

ZXAN(config-vlan)#voip-ctrl

ZXAN(config-vlan)#voip-bind

ZXAN(config-vlan)#exit

ZXAN(config)#

ZXAN(config)#interface gei_1/9/1

ZXAN(config-if)#

ZXAN(config)#exit

ZXAN#write

All Rights reserved, No Spreading abroad without Permission of ZTE 101


ZTE Low Level Design for MSAG Upgrade Project

9 Power Solution

9.1 Overview

In the current fix line network, there two types of FL equipment, MSAG 5200(in NGN
project) and MSAG C300M (in TEP project). For existing MSAG sites, the power
system and MSAG have an integrated design, and has worked more than ten years.
The rectifier system is facing the shortage of spare parts, and the batteries are coming
to end of life.

At the same time, the rectifier system, the batteries and MSAG share the total space.
This design has leaded the internal temperature rising, and the batteries will work in
poor environment condition.

9.2 Power System Design of MSAG Upgrade Solution

 According to the environment of Ethiopia and the requirement from the upgraded MSAG, the
new power system should be designed for this project. The new power solution should provide
the main following functions:

 Rectifier and battery spaces are independent with separated cooling system. The rectifier space
will adopt the heat ex-changer and the battery space will use DC air conditioner.

1. heat ex-changer inside of main equipment rack: power consumption is 200W, the heat
dissipation ability is 1800W.
2. heat ex-changer inside of main power system rack: power consumption is 100W, the heat
dissipation ability is 1000W.
3.  air-conditioner inside of battery rack: power consumption is 320W.

 Advanced rectifier system can provide more powerful functions, such as modular design, higher
efficiency (≥95% (peak efficiency); ≥94.5%(full load); ) power system, and fast charging.New cycling
batteries :ZXDC12 HL170 (170AH)to against the poor commercial power condition. Refer to PD
of battery.

All Rights reserved, No Spreading abroad without Permission of ZTE 102


ZTE Low Level Design for MSAG Upgrade Project

 Enough battery capacity guarantees backup time, and improves the customer experience and
network KPI.

The battery configuration is 3 banks of 170AH battery, based on the different load, back up time will be
change:

C =1.1× KT×T×I1 T=C/(1.1×KT×I1)

1.1-----Redundancy factor

I1----load current

12V battery KT table


MSAG Load Backup time(h) MSAG Load Backup time(h)
≤ 20A ≥ 23.2 26A 17.8
21A 22.1 27A 17.2
22A 21.1 28A 16.6
23A 20.2 29A 16
24A 19.3 30A 15.5
25A 18.5 ≥30A ≤ 15

Power down priority control: LLVD1 and BLVD

LLVD1-45V BLVD 43.2V

 This function can ensure that the MSAG load will work maximum time after the grid power off.

a) LLVD1 connect for the common loads, like the heat ex-changer, DC cooling
system and so on. Those equipment will be firstly down when the voltage drop
to LLVD1 voltage 45v.

b) BLVD for the important loads, like MSAG. Those load will be off when the
battery voltage drop to 43.2V(BLVD), and the important loads will be closed if
the AC power still not recovered.

All Rights reserved, No Spreading abroad without Permission of ZTE 103


ZTE Low Level Design for MSAG Upgrade Project

Figure 9-38 The upgraded Power solution for enhanced MSAG

9.3 Rectifier unit

The ZXDU68 B301 system is a 6U height, 19-inch width embedded DC power system.
The system can provide power to -48 V series communication equipment. When fully
configured, the system is equipped with four ZXD3000 rectifiers and can provide a
rated output current of 200A.

Figure 9-39 the high efficiency rectifier unit

All Rights reserved, No Spreading abroad without Permission of ZTE 104


ZTE Low Level Design for MSAG Upgrade Project

ZXD3000 power module can support high efficiency, in the sleep mode, the output
power of the rectifier is lower than 4W.

Figure 9-40 the high efficiency 3KW Power unit

9.4 The high loop performance battery

ZXDC12 HL series battery can achieve a high charge rate of 0.32C 10 , and has
excellent deep cycle performance with 1500 cycles@60%DOD at 25℃.The designed
life is 12 years.

Figure 9-41 ZXDC12 HL170Ah Battery

All Rights reserved, No Spreading abroad without Permission of ZTE 105


ZTE Low Level Design for MSAG Upgrade Project

9.5 Central Monitoring System(iENERGY)

U31 server

Client Clien Databas Server


t e

IP NETWORK
ip
IP network

RJ45 RJ45 RJ45


RJ45 RJ45 RJ45

NE

NO Parameter Default Value Remark


.

  Menu > Network > Network Type

1 MODEM Exist No   Net Source can be set to


ETHO only when MODEM
Exist is set to No.

2 Net Source ETHO  Set it to ETHO

  Menu > Network Para. > Wire Net.Para.

3 TCP Mode Server Must set to Server

4 Local IP Mode Static Set this parameter based on


network requirement.

If Local IP Mode is set to


Dynamic, Local IP, Mask,

All Rights reserved, No Spreading abroad without Permission of ZTE 106


ZTE Low Level Design for MSAG Upgrade Project

and Gateway are


automatically obtained,
which do not need to be set
manually.

5 Local IP 192.168.1.2 If Local IP Mode is set to


Static, set it to the actual IP
address.

6 Mask 255.255.255.0 If Local IP Mode is set to


Static, set it to the actual sub-
net mask.

7 Gateway 192.168.1.1 If Local IP Mode is set to


Static, set it to the actual
gateway IP address.

8 Remote IP-1# Enter the U31 server’s IP address. Initial address:0.0.0.0

9 Remote Port-1# 5000 Enter the actual U31’s


ETHO Port no.

10 Acronyms

Table 10-56Acronyms

Acronyms English

Asymmetric Digital
ADSL
Subscriber Line

AC Alternating Current

ACL Access Control List

AG Access Gateway

CATV Cable Television

CES Circuit Emulation Service

CLI Command Line Interface

All Rights reserved, No Spreading abroad without Permission of ZTE 107


ZTE Low Level Design for MSAG Upgrade Project

Dynamic Bandwidth
DBA
Allocation

DC Direct Current

DDN Digital Data Network

DSL Digital Subscriber Line

Element Management
EMS
System

Ethernet Passive Optical


EPON
Network

FTTB Fiber to the Building

FTTC Fiber to the Curb

FTTCab Fiber to the Cabinet

FTTH Fiber to the Home

GE Gigabit Ethernet

Giga Ethernet Interface


GEI
Card

Gigabit Passive Optical


GPON
Network

ITU-T Rec. H.248


H.248 Gateway Control
Protocol

Hypertext Transfer
HTTP
Protocol

HW High speed data Way

Internet Group
IGMP
Management Protocol

IP Internet Protocol

Internet Protocol
IPTV
Television

IPV4 Internet Protocol version

All Rights reserved, No Spreading abroad without Permission of ZTE 108


ZTE Low Level Design for MSAG Upgrade Project

Internet Protocol version


IPV6
4

Integrated Services
ISDN
Digital Network

International
Telecommunication
ITU-T Union -
Telecommunication
Standardization Sector

Link Aggregation Control


LACP
Protocol

LAN Local Area Network

MDF Main Distribution Frame

MDU Multiple Dwelling Unit

MG Media Gateway

Media Gateway
MGC
Controller

MSAG Packet
MPRB Processing & Resource
CardType B

Multi-Service Access
MSAG
Gateway

Multiple Spanning Tree


MSTP
Protocol

NE Network Element

Optical Distribution
ODF
Frame

Optical Distribution
ODN
Network

OLT Optical Line Terminal

All Rights reserved, No Spreading abroad without Permission of ZTE 109


ZTE Low Level Design for MSAG Upgrade Project

ONU Optical Network Unit

PON Passive Optical Network

Plain Old Telephone


POTS
Service

Point to Point Protocol


PPPoE
over Ethernet

Public Switched
PSTN
Telephone Network

PVC Permanent Virtual Circuit

Real-time Transport
RTP
Protocol

Single-pair High Digital


SHDSL
Subscriber Line

SLC Subscriber Line Circuit

VCI Virtual Channel Identifier

Very High Speed Digital


VDSL
Subscriber Line

Very High Bit Rate


VDSL2
Digital Subscriber Line 2

Virtual Local Area


VLAN
Network

Voice over Internet


VLAN
Protocol

Virtual Path Identifier


VPI

WAN Wide Area Network

All Rights reserved, No Spreading abroad without Permission of ZTE 110