You are on page 1of 2

1 2 3 4 5 6

515
30×20×2
30 475

18
140

130
255
Supply
R3/4" R3/4"
795 30 160
9 7 8 4-φ10×5
Return
128
Main technical parameters
Z101 Model CFP-1.7WA
Cooling capacity 2kW
Heating capacity 2.2kW

155
3
Air flow 340m/h
Fan capacity 55W
3
Water flow 0.42m/h
7℃
6-φ10×5 DN20(Rc3/4")
234

180
56

DN20(Rc3/4")
Power supply AC220V 50Hz 1ph
Outline dimension 795×475×255mm
90

Quantity left type :3sets

42
right type:2sets
515
120 545 15
9 Connection box 1
Installation drawing 8 YDK110/20-6 Motor 1
Centrifugal fan

≥150
7 SYP145/190J 1
≥200
6 2
≥200
5 1
4 2

≥150
3 1
2 Water pan 1
Technical requirements
1.Fan coil shall be insulated; insulation material must be stick firmly. The dimensions
1 Surface air cooler 1
in drawing don't include the thickness of rubber insulation material.
2.Each part shall be tidy and without leakage. Outside surface of the unit can have
crack, rust or indentation. FMC DOCKYARD LTD.
COSTAL PASSENGER VESSEL FMC-84 1:1
3.face the front of air conditioner, if chilled water inlet/outlet pipe andEl terminal
box are at the left side of the unit.
4.Surface air cooler should be equipped with drain valve and exhaust valve, drain valve C1
shall be set in the bottom of surface air cooler. General Drawing
5.Test pressure of fan coil is 1.0MPa (pressure).
WM19037-CFP-1.7WA.01-00ZT
6.Water pond height is 80mm, double-deck type.
7.The color of this unit is RAL9016 Traffic white.
8.The machine parts provide FX-6 temperature controller and electric 3-way valve.
1 2 3 4 5 6
715
30×20×2
30 475

18
140

130
255
Supply
R3/4" R3/4"
995 30 160
9 8 7 4-φ10×5
128 Return
Main technical parameters
Z101 Model CFP-3WA
Cooling capacity 3.5kW
Heating capacity 3.8kW

155
3
Air flow 680m/h
Fan capacity 80W
3
Water flow 0.75m/h
7℃
6-φ10×5 DN20(Rc3/4")
234

180
DN20(Rc3/4")
56

Power supply AC220V 50Hz 1ph


Outline dimension 995×475×255mm
90

Quantity left type :3sets


right type:3sets

42
715
120 745 15
9 Connection box 1
Installation drawing 8 YSK110/30-6 Motor 1

≥150
7 SYP145/130J Centrifugal fan 2
≥200 6 2
≥200
5 1
4 2

≥150
3 1
2 Water pan 1
Technical requirements
1.Fan coil shall be insulated; insulation material must be stick firmly. The dimensions
1 Surface air cooler 1
in drawing don't include the thickness of rubber insulation material.
2.Each part shall be tidy and without leakage. Outside surface of the unit can have
crack, rust or indentation. FMC DOCKYARD LTD.
COSTAL PASSENGER VESSEL FMC-84 1:1
3.face the front of air conditioner, if chilled water inlet/outlet pipe andEl terminal
box are at the left side of the unit.
4.Surface air cooler should be equipped with drain valve and exhaust valve, drain valve C1
shall be set in the bottom of surface air cooler. General Drawing
5.Test pressure of fan coil is 1.0MPa (pressure).
WM19037-CFP-3WA.01-00ZT
6.Water pond height is 80mm, double-deck type.
7.The color of this unit is RAL9016 Traffic white.
8.The machine parts provide FX-6 temperature controller and electric 3-way valve.