INDIAN RAILWAY INSTITUTE OF ELECTRICAL ENGINEERING

NASIK ROAD
PERFORMANCE TEST REPORT Ref.no.: 300

MODE OF OPERATION : INDIVIDUAL RUN

Suction Transmitter Delivery Transmitter * Velocity Total Flow Meter Discharge Voltage Current Power Motor Pump Overall Temp.1 Temp.2
Reading Reading Reading
Pump Guage Head Head Input Output Efficiency
SL.No. Frequency
Dist. Correction (H)

1 2 3 4 (2-1+3+4) (Q)

(Hz) bar m bar m m m m lps Volts Amps watts kW kW % 'C 'C

1 0.00 0.07 0.71 0.25 2.55 0.54 0.00 2.38 0.00 0.00 0.00 0.00 0 0.00 35.20 30.40
COMPUTED READINGS AT RATED FREQUENCY 50 Hz 0.00 0.00 SHUT OFF
2 16.12 0.05 0.51 0.25 2.55 0.54 0.10 2.68 3.48 3.48 455.00 2.62 181 0.18 35.20 30.40
COMPUTED READINGS AT RATED FREQUENCY 50 Hz 2.68 3.48 0.09 50.80
3 23.58 0.03 0.31 0.33 3.37 0.54 0.25 3.85 5.35 5.35 294.00 2.78 426 0.43 35.30 30.60

File : D:\IRIEEN_pumptest\17-06-2021\p1 system curve pgs.PDA


COMPUTED READINGS AT RATED FREQUENCY 50 Hz 3.85 5.35 0.20 46.96
4 33.79 -0.01 -0.10 0.47 4.79 0.54 0.53 5.97 7.84 7.84 368.00 3.15 1095 1.10 35.20 30.30
COMPUTED READINGS AT RATED FREQUENCY 50 Hz 5.97 7.84 0.46 41.72
5 40.11 -0.05 -0.51 0.59 6.02 0.54 0.76 7.83 9.37 9.37 409.00 3.15 1789 1.79 35.10 30.60
COMPUTED READINGS AT RATED FREQUENCY 50 Hz 7.83 9.37 0.72 40.18
6 50.00 -0.09 -0.92 0.92 9.38 0.54 1.04 11.88 10.98 10.98 445.00 5.61 3329 3.33 34.70 30.40

COMPUTED READINGS AT RATED FREQUENCY 50 Hz 11.88 10.98 1.28 38.40

Date :17.06.21

Tested by:

MBK

Checked by:

MS