You are on page 1of 1

RAIN CII

60% SO2 removal case


Stream 8 7 6 5 4 3 2 1
Gas Volume, ACFM 500 TBD 350 n/a n/a 425,705 347,542 351,769

Temp, Deg F 100 TBD 100 n/a 80 450 200 200

Negative pressure, inches of W.C. TBD n/a n/a -28 -30.75 -36.25

Flue gas Density, #/CF TBD n/a n/a 0.0364 0.05227 0.0477

SO2 n/a n/a n/a n/a n/a 4,130 #/hr 1,858 #/hr 1,652#/hr

8,310 CaSO4,
4820 Ca(OH)2, 419
Particulate, lbs/hr 1,007,262 TBD inerts, ash and n/a 500 Flyash, etc 1,007,265 2.87
alkali inerts
Ca(OH)2

Liquid phase H20 n/a n/a n/a n/a 78 gpm 0 0 0

Hydrated lime cost Based on


$419/hour
guarantee consumption, scrubber
Hydrated lime cost Based on
$377/hour
estimated consumption, scrubber
Hydrated lime cost Based on Spray
$838/hour
dryer
Hydrated lime cost Based on Single
point injection, this would require $1676/hr
some gas cooling also to meet 60%

Assumptions Ca(OH)2 cost $160/ton