9209-509 DECEMBER 2016
Level 5 Advanced Technician
Diploma in Electrical and
Electronic Engineering
Principles and operation of electrical.machines

If provided, stick your candidate Monday 5 December 2016


barcode labei here. 09:30 12:30

Candidate name (first, last)


First
Last

Candidate enrolment number Date of birth (DDMMYYYY) Gender (M/A)

Assessment date (DDMMYYYY Centre number Candidate signature and declaration

If any additional answer sheets are used, enter the additional number of pages in this box.
Please ensure that you staple additional answer sheets to the back of this answer
booklet, clearly labelling them with your full name, enrolment number, centre number
and qualification number in BLOCK CAPITALS.
All candidates need to use a black/blue pen. Do not use a pencil or
gel pen.
If provided with source documents, these documents will not be returned to City & Guilds,
and will be shredded. Do 'not write on the source documents.
1 declare that I had no prior knowledge of the questions in this assessment
and that I will not divulge to any person any information about the questions.

You should have the following for this assessment


a non-programmable scientific caiculator
a pen with black or blue ink
a pencil
drawing instruments
General instructions
Use black or blue ball-point pen. Use pencil for drawmg only.
.The marks for questions are shown in brackets.
Answer all questions.
Answer the questions in the spaces provided. Answers written in marg1ns
or on blank pages will not be marked.
Cross through any work you do not want to be marked.
Round numbers to three significant figures where appropriate.
Show all calculations. f you use a calculator, show sufficient steps to justify
your answer.
Write all your working out and answers in this booklet.

The Cty and Gakts of Londor insttute 2016


ST0048831 A3 PO4500121449 10758357
416067160450116
5 December 2016

plain the function and operation of automatic tapchangers on power transformers. (8 marks)

**** ******* ******


* *****

*** ****

**** * ****

**

(Total marks 8)

2 Evaluate a method of earth fault protection for a three-phase power transformer using
Current transformers. (8 marks)

****************** ******

************ ******************* ******* *********

** * **

**** *****

(Total marks 8)

2
+
+
9209.509 5 Decem

3 Atfull load, a 325 kVA transformer has an iron loss of 1.5 kW anda copper loss of 4.5 k.
Calculate the efficiency at 70 %full load at a power factor of 0.8 lag (14 mark

(Total marks 14)

3
See next page
416067160450316
+
5 December 2016

Draw a labelled equivalent circuit of an induction motor 8 marks)

the
b An induction motor has the following impedance parameters referred to
stator and measured in ohms per phase
Stator R 0.2 X1 =1
=

Rotor R2 = 0.3 X2 = 1

Magnetising components Rm 150 X 20 (2 marks)


Calculate the value of the load component at 0.05 slip.

(Total marks 10)

4
A1 EAE716nAFnA1r
9209-509 5 Decem

5 A 40 kW three-phase irnduction motor has stator losses of 1 kW and iron losses of


0.5 kW when running with a slip of 0.04. Mechanical losses are 0.8 kW.
a) Calculate the
rotor copper losses (4 marks)

ii) mechanical power developed by the rotor (2 marks)

ii) efficiency. (4 marks)

b) If the slip is increased to 0.05, calculate the efficiency.


(6 marks)

* *

(Total marks 16)

+ 416067160450516
See next page
5 December 2016

Draw a labelled phasor diagram for a synchronous machine


running with a lagging power factor. operating asa motor
(8 marks)

6
A1C 71AnEnci
9209 S09 5 Decer

b) The gereraled emls of two alternators, A and B, are 1000 V and (1000-j100) v
respectively, with corresponding impedances of (0.1 +j1.0) 2 and (0.2 + j2) 2.
Both alterrnators are connected to a common busbar of
voltage (1100-j100) V.
Calculate the
) load currents of each machine (8 marks)

I) total current
(2 marks)

(Total marks 18)

7
See next page
416067160450716
5 December 2016

which must be
lain the consequences of not satisfying the four conditions
busbar system (12 marks)
chieved when synchronising an alternator to an infinite

**

* *
***** ***
**

(Total marks 12)

NN +
9209-509 5 Dece

8 a) Explain how a three-phase motor can'be started using a variable frequency supply,
giving details of the equipment required. (8 ma

b) A 1.5 kW
synchronous motor withastar connected stator has a synchronous
reactance of 1.4 2 per phase. It is
operated at unity power factor from a 2.3 kV
supply.Calculate the
motor emf per phase
(6 marks)

*******************

- - -

load angle.
(1 mark)

See nextpage
416067160450916
5 December 2016

xplain the effect of over exciting a synchronous motor. (3 marks)

(Total marks 18)

9 Two generators rated at 20 MW, O.15 p.u.reactance and 10 MW, 0.1 p.u.reactance,
feed an 11 kV/33 kV transformer rated 30 MVA with 0.05 p.u. reactance.
The transformer is connected to a 33 kV cable. The cable has a symmetrical short
circuit fault with an impedance (3 + j15)2.
Calculate the overall fault MVA. (20 marks)

-- --

(Total marks 20)

10 +
416067160451016
9209-509 5 Dec

10 a) Explain howa bipolar transistor can be used as a power switching device.


6

b) With the aid of a circuit


of a voltage source diagram, analyse the operation of the three main parts
bridge inverter for supplying a three-phase induction motor.
(10 marks

11
416067160451116 See next page
5 December 2016

With the aid of time related diagrams, explain the operation of a pulse width
modulated inverter suitable for supplying a three-phase induction motor.
(10 marks)

12
9209-509 5 Decembe 2016
+
Question 10 c) continued

** * **

* " **

-- -

(Total marks 26)

13 End of assessment