FEATURES
• universal input (85~264 Vac)
• 2.5 × 1.8 x 0.75 in (63.5 x 45.7 x 19 mm)
• class B EMI performance, meets CISPR32 / EN55032
• output short circuit, overcurrent & overvoltage protection
• designed to meet: IEC/EN/UL 60335 & 62368
• safety certified: IEC/EN/UL 62368
MODEL output
voltage
output
current
output
power
ripple
and noise1
efficiency2
VOF-15C - SXX
cui.com
CUI Inc │ SERIES: VOF-15C │ DESCRIPTION: AC-DC POWER SUPPLY date 10/25/2019 │ page 2 of 6
INPUT
parameter conditions/description min typ max units
85 264 Vac
voltage
100 370 Vdc
frequency 47 60 Hz
at 115 Vac .37 A
current
at 230 Vac .22 A
at 115 Vac 20 A
inrush current
at 230 Vac 30 A
no load power consumption 0.5 W
OUTPUT
parameter conditions/description min typ max units
3.3 Vdc output models 20,000 µF
5 Vdc output models 10,000 µF
9 Vdc output models 5,800 µF
capacitive load
12 Vdc output models 5,200 µF
15 Vdc output models 4,500 µF
24 Vdc output models 1,000 µF
3.3 Vdc output models ±3 %
initial set point accuracy
all other models ±2 %
line regulation at full load ±0.5 %
load regulation from 0~100% load ±1 %
at 115 Vac, full load 10 ms
hold-up time
at 230 Vac, full load 60 ms
switching frequency 60 kHz
temperature coefficient ±0.02 %/°C
PROTECTIONS
parameter conditions/description min typ max units
output voltage clamp, auto recovery
3.3, 5 Vdc output models 7.5 Vdc
over voltage protection 9 Vdc output models 15 Vdc
12, 15 Vdc output models 20 Vdc
24 Vdc output models 30 Vdc
over current protection hiccup, auto recovery 130 300 %
short circuit protection hiccup, continuous, auto-recovery
cui.com
CUI Inc │ SERIES: VOF-15C │ DESCRIPTION: AC-DC POWER SUPPLY date 10/25/2019 │ page 3 of 6
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature see derating curves -25 70 °C
storage temperature -25 85 °C
storage humidity non-condensing 90 %
DERATING CURVES
Load vs. Ambient Temperature Load vs. Input Voltage
(at 85~264 Vac / 100~370 Vdc Input Voltage) (at 25°C Ambient Temperature)
100 100
85
80
Load (%)
Load (%)
75
60 60
40 40
20 20
cui.com
CUI Inc │ SERIES: VOF-15C │ DESCRIPTION: AC-DC POWER SUPPLY date 10/25/2019 │ page 4 of 6
EFFICIENCY CURVES
Efficiency vs. Input Voltage Efficiency vs. Load Current
(at full load) (at 230 Vac)
DESIGN REFERENCE
cui.com
CUI Inc │ SERIES: VOF-15C │ DESCRIPTION: AC-DC POWER SUPPLY date 10/25/2019 │ page 5 of 6
MECHANICAL
parameter conditions/description min typ max units
dimensions 63.50 x 45.70 x 19.00 mm
weight 36 g
PIN-Out
PIN Function Connector Terminal
1 AC(L)
VH-3A VH-3Y
2 NoPin or B2P3-VH or VHR-3N
or the same Spec. or the same Spec.
3 AC(N)
4 -Vo VH-2A VH-2Y
or B2P-VH or VHR-2N
5 +Vo
or the same Spec. or the same Spec.
cui.com
CUI Inc │ SERIES: VOF-15C │ DESCRIPTION: AC-DC POWER SUPPLY date 10/25/2019 │ page 6 of 6
REVISION HISTORY
Headquarters
20050 SW 112th Ave. Fax 503.612.2383
Tualatin, OR 97062 cui.com
800.275.4899 techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.