Ventilation Portfolio – Hospital Products
CV If you want to replicate CV mode where the ventilator triggers and cycles all breaths then set the trigger type to OFF.
T If you want to replicate T mode where the ventilator triggers and cycles all breaths then set the trigger type to OFF.
Synchronized Intermittent Mandatory Ventilation (Volume Control) mode is similar to SIMV-PC, but with volume
SIMV SIMV-VC
control.
Synchronized Intermittent Mandatory Ventilation (Pressure Control) mode is a pressure control mode that provides a
mixture of mandatory, assist-control and spontaneous breaths with optional pressure support. It guarantees one
PC-SIMV SIMV-PC
mandatory breath in each cycle. The breath rate determines the length of the cycle. Optional: Inspiratory Time
min/max. for the spontaneous breaths.
Simple
Modes and settings: Trilogy 202 to Trilogy EV300
Pressure Support Ventilation mode is patient-triggered, pressure-limited, and flow-cycled. The patient
S PSV determines the breath rate and timing so it is recommended to set back-up ventilation. Optional: AVAPS and
Ti min/max.
Spontaneous/Timed is a bi-level therapy mode where each breath is patient-triggered and patient-cycled, or
S/T S/T
ventilator-triggered and ventilator-cycled.
In Continuous Positive Airway Pressure mode, all breaths are spontaneous with the CPAP set pressure
CPAP CPAP
delivered in both inhalation and exhalation.
AVAPS-Auto EPAP mode automatically adjusts pressure support, to maintain the target tidal volume, and
EPAP, to maintain a patent airway, within the set min/max ranges; and simplifies the set-up of the backup
AVAPS-AE AVAPS-AE
breath rate when set to auto.
Note: auto back-up rate maximum is 20bpm. Optional: Inspiratory Time min/max.
Simple
Modes and settings: Trilogy 202 to Trilogy EV300
Once enabled, this setting treats inspiration time as a variable value for patient-initiated, patient-cycled
breaths.
Inspiratory Time
-
Min/Max
It is available in S/T, PSV, SIMV-PC, SIMV-VC, and AVAPS-AE modes, under Advanced in the Prescription
Settings window.
This sets the maximum rate of change in pressure between the min and max values while AVAPS is seeking a
AVAPS Rate AVAPS Speed
volume target.
PC Breath Available in AVAPS-AE mode. When PC Breath is on, the set inspiratory time applies to
-
(AVAPS-AE) all breaths.
In Trilogy EV300, available in A/C-VC mode under Advanced in the Prescription window. Sigh volume can be
Sigh Sigh set between 1.5 – 2.5 times the set volume and the frequency every 50 – 250 breaths. While in Trilogy, sigh
was fixed at 1.5 times the set volume every 100 breaths.
Available under Advanced in the Prescription window. When turned on an Apnea interval needs to be set in
Back-up
- the alarm settings tab. Within the apnea interval; if no breaths are triggered by the patient, the vent delivers
Ventilation
breaths at the set pressure of volume based on the Backup Rate and Backup Insp Time.
Adaptable
Dynamic parameters
1 Bacteria/Viral filter
2 Exhalation leak port
3 Non-vented (without integrated leak) Non-invasive Invasive
NIV mask
4 Tracheostomy tube
(trach adapter not shown and optional to connect to circuit)
1
5 Endotracheal Tube (ETT)
(trach adapter not shown and optional to connect to circuit)
1 Bacteria/Viral filter
2 FEP exhalation leak port
3 Non-vented (without integrated leak) Non-invasive Invasive
NIV mask
4 Tracheostomy tube 2
(trach adapter not shown and optional to connect to circuit)
1
5
Endotracheal Tube (ETT)
(trach adapter not shown and optional to connect to circuit)
Passive circuit: 6
Option 3 – J circuit 5 7
1 Bacteria/viral filter
2 Wye (Y) connector
3 Exhalation leak port Non-invasive Invasive
4 End cap
5 Non-vented (without integrated leak) 2
NIV mask 1
6 Tracheostomy tube
(trach adapter not shown and optional to connect to circuit)
3
4
Dual Limb circuit: 8
Option 1 7 9
1 Bacteria/Viral filter
2 Proximal pressure line
3 Dual Limb active exhalation valve Non-invasive Invasive
2
3
4
Trilogy EV300 Ventilator Overview
1. On/Off indicator
2. AC power indicator
3. Alarm silence
button/alarm indicator
4. Alarm lens
5. Touchscreen
4. Air vents
5. Air inlet
6. O2 blending module
(OBM)
7. O2 inlet fitting
Trilogy EV300 Ventilator Overview
1. USB port
5. Dual-limb active
exhalation valve connection
(from patient)
1. AC power connector
2. Air vents
6. USB port
8. DC power connector
Trilogy EV300 Ventilator Overview
1. Menu bar
2. Workspace
3. Status bar
4. Monitored
parameters pane
Use the menu bar to navigate, manage alarms, set ventilator options, and see the
active prescription:
1. Tap the Home button to go to the home window
4. When in the home window, tap the Prescription List to see a list of prescriptions
Use the status bar to monitor device status and the availability of manual
therapeutic actions:
1. Touch the
Prescription Settings icon
3. Select the
appropriate mode from
the dropdown menu
4. Touch Accept to
save the change
1. Touch the
Prescription Settings
icon
3. Use – or + to increase
or decrease setting
Alarm Changes
3. Use – or + to increase
or decrease setting
• Device Options
• Data Transfer
• Information
• Device language
• Alarm loudness Screen
• brightness Light bar on/off
• Auto screen lock Screen saver
• System date and format
• System time and format FiO2
• sensor on/off
• NFC on/off Bluetooth on/off
• Encryption on/off Pressure &
• CO2 units of measure
•
•
•
• Transfer Data
• Changes to alarms,
prescriptions, accessories and
oxygen
• 30-second averages of each therapy
parameter related to patient
provided thereapy CO2 monitored
data
• Oximeter data
• FiO2 monitored data
•
• Model number
• Serial number
• Software version number
• Hardware version number
• Internal battery serial number
• Detachable battery serial
number
• Operational Hours
• Total blower hours
• Total patient hours
• Software licenses
• Page up/down