You are on page 1of 260

5 Port Solenoid Valve New

Plug-in Type
Thanks to the flow increase, valve size can be reduced!
Saves energy and space .
New
SY3000 SY5000 SY7000
10 mm 15 mm
18 mm

ø2, ø3.2,
ø4, ø6, ø8∗
fittings are connectable.
∗ Type M10/M11 manifold

At 300 mm/s ø4, ø6, ø8


fittings are connectable.
ø32
Existing At 300 mm/s
Valve ø6, ø8, ø10, ø12
size fittings are connectable.
ø50 DOWN ø50
Existing
Possible to drive cylinders At 300 mm/s
50
Valve

Up to ø
(ø80 at 100 mm/s)
ø63
size
DOWN
ø63
Existing
Possible to drive cylinders

Plug-in
Page 16
Sub-plate newly added!
Up to ø63 ∗
ø80
(ø125 at 100 mm/s)
SY3000/5000
Possible to drive cylinders
New
Up to

ø80
(ø160 at 100 mm/s)
∗ Values based on comparison with the existing
SMC model. For details, refer to page 1.

Power consumption
∗ Refer to Features 2.

0.1 w (With power saving circuit)

New¡The SY7000 newly added ¡


0.35 w (Standard)
Plug-in Sub-plate Rubber seal (Service life: 70 million cycles)
¡With residual pressure release valve ¡With safety slide locking manual override Metal seal (Service life: 200 million cycles)
¡D-sub connector [IP67] manifold ¡PC wiring (with power supply terminal) manifold ∗ According to SMC life test conditions

Series SY3000/5000/7000 CAT.NAS11-103C


5 Port Solenoid Valve
Plug-in Metal Base [IP40]
Side ported From page 29 Bottom ported From page 29 Top ported From page 49

Plug-in Connector Connecting Base [IP67 Note)]


Note) Refer to page 77 for details on IP67.

Manifold
Side ported From page 81 Bottom ported From page 81 Top ported From page 93

Plug-in Compatible sub-plate type  Connector


(Only SY3000/5000) type manifold Plug-in
New

¡IP67 enclosure in standard specifications


¡M12 waterproof connector type ensuring
easy attaching/detaching and wiring
¡Applicable to the side, top and bottom <Enlarged view
ported. (4A, 2B port) of the connector>
Connector type manifold 32 outputs
Wiring
D-sub connector Flat ribbon cable PC wiring Terminal block box
Lead wire Circular connector Serial transmission
Serial Transmission Variations
Integrated-type (for input/output) Integrated-type
Gateway-type serial transmission system serial transmission (for input/output) serial Integrated-type (for output) serial transmission system
system (Fieldbus system) transmission system
Series EX510 EX500 EX600 EX250 EX260 EX126 EX120

Applicable protocol

DeviceNetTM
PROFIBUS DP
CC-Link
EtherNet/IPTM
EtherCAT
PROFINET
CANopen
AS-Interface
OMRON CompoBus/S
CompoNetTM

Features 1
Series SY3000/5000/7000
Power saving
Power consumption [Electrical power waveform with power saving circuit]
Applied voltage
Power consumption is
reduced by power saving
24 V
circuit.

0.1w 0.35 w
0V Power consumption is decreased by
approx. 1/3 by reducing the wattage
Standard required to hold the valve in an
0.35 (0.9) W
With power energized state. (Effective
saving circuit
0.1 (0.4) W energizing time is over 67 ms at 24
With power Standard VDC.) Refer to the electrical power
saving circuit 0W waveform as shown on the left.
67 ms (40 ms)

Space saving/Improved operability


The value in ( ) are for the quick
response and high pressure types.

Wiring, piping and operation are integrated on one side. 4-position dual 3-port valve available
Multiple layer type is available as an From page 226 (Only rubber seal type)
option. This saves space in Piping • Two 3-port valves built into one body
the lateral direction.
Wiring Can be operated from the top.

SUP stop valve spacer


with residual pressure
release valve
Individual SUP/EXH
spacer

A side
spool valve B side
Bottom ported is prepared. Space saving spool valve
Top or bottom ported reduces
the footprint.
• 3-port valves on the A and B sides can operate independently.
• When used as a 3-port valve, only half the number of stations is required.
• Can also be used as a 4-position, 5-port valve.
• 4-position dual 3-port valve with back pressure check valve is
available.
• Combination examples

Series A side B side


SYA030 N.C. valve N.C. valve
Panel fitting
Installation SYB030 N.O. valve N.O. valve
SYC030 N.C. valve N.O. valve

Different sizes (SY3000/5000 or SY5000/7000) can be mixed! From page 189 Manifold overall length

Possible to reduce installation space, the number of serial units and wirings. Approx. 29%
reduced
For serial transmission SY5000 manifold SY3000 manifold Mixed manifold
EX260 SY5000 3 stations SY3000 4 stations SY5000 3 stations SY3000 4 stations

BA BA BA B A B A B A B A B A B A B A B A B A B A B A

Installation 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A

space
12 B 12 B 12 B 12 B 12 B 12 B 12 B 12 B

12 B 12 B 12 B 12 B 12 B 12 B

136.7 mm 124.7 mm 186.7 mm

2 sets 1 set
Number of
serial units

Features 2
5 Port Solenoid Valve
Improved safety
Back pressure check valve
This prevents actuator and air operated valve malfunctions caused by the exhaust from other valves.∗
Built-in valve type Back pressure check valve Retrofit or pre-installed type
(Check seal) If the product is affected by back pressure after
installation, the back pressure check
(A) (B)
4 2 valve assembly can be added. Page 232

5 1 3
5 4 1 2 3 (EA) (P) (EB)
(EA) (A) (P) (B) (EB)

∗ For back pressure check valve precautions,


refer to the Specific Product Precautions on page 243. Back pressure check
valve assembly

New With residual pressure release valve (Only SY5000) Page 13 IP67 compliant
Indicator
For residual pressure release of [When 1(P) port is pressurized] [When 1(P) port is not pressurized]
the 3-position closed center valve When P port is not pressurized
EXH. EXH.
·The pressure of the 4 (A) and 2 (B) ports is al-
EXH. EXH.
so exhausted automatically at the same when When P port is pressurized
the pressure of the 1 (P) port is exhausted. 4 2 4 2
·The pressure can be visualized using the indicator (red).
·Since this valve is not a spacer type, the flow rate is 5 3 5 3
1 1
equivalent to that of the normal closed center valve.

SUP stop valve spacer Page 227 Double check spacer Page 227
(With residual pressure release valve) (With residual pressure release valve)
Air supply to each valve can be stopped individually. The Long time of intermediate stop and position holding are possible.
valve and cylinder can be replaced without stopping other [Intermediate stop] [Drop prevention]
devices and equipment. Button for manual release
of residual pressure Double check spacer assembly Double check spacer assembly
Button for manual release
To exhaust residual pressure
of residual pressure on cylinder side.
To exhaust residual pressure 2-position single valve
on cylinder side. 4(A)
2(B)

SUP stop valve


spacer assembly

4(A) 2(B) 5(EA) 4(A) 2(B) 5(EA)


1(P) 1(P)
3(EB) 3(EB)
5(EA)
1(P)
3(EB) Exhaust center 2-position single/double
2-position single valve example

With slide locking manual override


ON/OFF operation and locking can be performed with the manual slide. ON

OFF
ON/B side

Yellow Blue OFF/A side


B side A side

ON/OFF state can be checked at a glance.


Features 3
Series SY3000/5000/7000
Improved safety
New With safety slide locking manual override
SY3000/5000/7000-X13 Page 14
SY7000-X13
Double action manual override prevents
incorrect operation! SY5000-X13
 Double action operation SY3000-X13

Before operation Operation 1 Operation 2


The slide manual overrides cannot be turned ON Operates the safety slide cover The slide manual overrides
with the safety slide cover. (OFF status: Locked) upward. (Unlocked) can be operated.
Safety slide cover Slide manual overrides

<OFF>

<ON>

 Visual check <Vertical sliding> <Horizontal sliding>


Red lines in three directions can be checked ∗ The safety slide cover cannot be locked when the slide manual override is turned ON.
whether the safety slide cover is unlocked (FREE).
Safety slide covers can be checked from their raised
Red lines and lowered positions.
Safety slide cover

Valve state
Unlocked (raised/lowered)

Piping options
Locked

To mount the piping on top To mount the piping on the side Mixed mounting of
top ported and side
Port block assembly One-touch fitting ported is possible.
for A, B port
Top ported
Replace the
Thread piping Body cover fitting and the
assembly port plug only.
Cover assembly

Side ported

Pressure switch
Port block assembly It is possible to detect the
for P, E port output of 4(A) and 2(B) port
with a pressure switch by
mounting the top ported
valve onto the side ported or
bottom ported manifold.
(Pressure switch etc., needs
Refer to page 247 for how to change piping types. to be ordered separately.)
Features 4
5 Port Solenoid Valve Variations
Wiring Manifold
Common
Connection

with residual pressure release valve

with residual pressure release valve


specification
Valve
Serial transmission

Individual SUP spacer


Individual EXH spacer
Series

SUP stop valve spacer

Double check spacer


Terminal block box

Circular connector

Negative common
Blanking plate
Positive common
Flat ribbon cable
D-sub connector

M12 connector
Variations

PC wiring

Lead wire

EX510
EX500
EX600
EX250
EX260
EX126
EX120
5 ports

SY303 
Sub-plate

From
— — — — — — — — — — — — — — — — 
Plug-in

page 18 
M12 connector SY503 

SY30
Bottom ported Side ported

Type
50 SY50 — — — — — — — — — —     
From
page 29 P.29 P.29 P.29 P.57
SY70
Metal Base

Type
SY30
51 SY50 — — — — — — — — — —     
From
page 29 P.29 P.29 P.29 P.57
SY70
Plug-in

SY33
Top ported

Type
52 SY53 — — — — — — — — — —     —
From
page 49 P.49 P.49 P.49 P.67
SY73
SY30
Bottom ported Side ported

Type
Plug-in Connector Connecting Base

10 SY50 — —     
From
page 81 P.81 P.81 P.81 P.99 P.109 P.119 P.129 P.137 P.149 P.157 P.165 P.173
SY70

Type
SY50
Manifold

11 — —     
From
page 81 P.81 P.81 P.81 P.99 P.109 P.119 P.129 P.137 P.149 P.157 P.165 P.173
SY70
SY33
Top ported

Type
12 SY53 — —     —
Plug-in

From
page 93 P.93 P.93 P.93 P.105 P.115 P.125 P.135 P.147 P.155 P.163 P.171 P.179
SY73
Standard  Option  Made-to-Order (Refer to page 14.)

Features 5
Series SY3000/5000/7000
Options (Pages 226 to 234) A, B Port Size Valve Options

Oil resistant (Other than designated turbine oil)


Silencer (One-touch fitting connection type)

Vacuum/Low pressure specification


Back pressure check valve assembly
Individual SUP block assembly
Individual EXH block assembly

SY3000/5000 mixed mounting


SY5000/7000 mixed mounting
One-touch fittings

SUP/EXH blocking disk


Label for blocking disk

(Manifold installed type)

Different pressures
Interface regulator

Mixed fitting sizes


Reverse pressure
Dual flow fitting

Enclosure IP67
C2 C3 C4 C6 C8 C10 C12

Plug (White)
Name plate
(N1) (N3) (N7) (N9) (N11)
M5 1/8 1/4

Elbow piping Note 1)

Elbow piping Note 1)

Elbow piping Note 1)

Elbow piping Note 1)

Elbow piping Note 1)


Straight piping

Straight piping

Straight piping

Straight piping
Straight piping
Straight piping
Straight piping

 — — — — — — — — — — — — — — — — — — — — — — — —  — —
External External
— Pilot Pilot

— —
— —
 — — — — — — —  — — — — — — — — —   —
— — External Individual External
Pilot SUP Pilot

— —
— —
 — — — — — — —  — — — — — — — — —  —  — —
— — Individual
SUP

— —
— — —
 — — — — — — —  — — — — — — — — —   —
— — External Individual External
Pilot SUP Pilot

— —
 — — — — Note 2)
         — — — — P.189  
— — External Individual External
Pilot SUP Pilot
— — — — P.193

— — — Note 2)
      —    — — — — — — — — — — P.189  
External Individual External
Pilot SUP Pilot
— — P.193
— —
— — Note 2)
      —   — — — — — — P.201  
— — — External Individual External
Pilot SUP Pilot
— — — P.201
Note 1) Elbow piping may specify size only in millimeters, depending on the port size. Refer to How to Order Manifold for details.
Note 2) Refer to Manifold Specifications on page 77 for details on IP67.
Straight piping Elbow piping
 One-touch fittings (Upward)

Features 6
Manifold Variations ·················································· Features 5 Valve Replacement Parts ············································ Page 11

Optimum Actuation Size Chart of Air Cylinder ·············· Page 1 With Residual Pressure Release Valve ······················ Page 13

Valve Specifications ······················································· Page 3 Made-to-Order for Valve ·············································· Page 14


(Specifications, Response Time, Weight)

Valve Construction ························································· Page 7

Sub-plate

Plug-in Sub-plate Page 16


M12 connector

Plug-in Sub-plate Specifications (M12 Connector) ······························································ Page 17

Sub-plate Parts No. ·················································································································· Page 19

Manifold

Plug-in Metal Base Page 26


Type 52/
Type 50/ Type 51/
Side ported Bottom ported Top ported

Type 50/Side Ported, Type 51/Bottom Ported, Type 52/Top Ported


Plug-in Metal Base ················································································································· Page 27
D-sub connector
D-sub Connector, Flat Ribbon Cable, PC Wiring System [IP40]
Flat ribbon cable

Type 50/Side Ported ············································································································· Page 29

Type 51/Bottom Ported ········································································································ Page 29


PC wiring
Type 52/Top Ported ·············································································································· Page 49

Wiring Specifications ··············································································································· Page 54

EX510 Gateway-type Serial Transmission System [IP20]


EX510
Type 50/Side Ported ············································································································ Page 57

Type 51/Bottom Ported ········································································································ Page 57

Type 52/Top Ported ············································································································· Page 67

Manifold Exploded View [Exploded View, Manifold Parts No.] ············································· Page 73

Front matter 1
Valve
Manifold

Plug-in Connector Page 76


Connecting
LOCK
LOCK
FREE

Type 10/ Type 11/ Type 12/


FREE

Sub-plate
Base Side ported Bottom ported Top ported

Type 10/Side Ported, Type 11/Bottom Ported, Type 12/Top Ported

Plug-in
Plug-in Connector Connecting Base ············································································· Page 77
D-sub PC
connector wiring
D-sub Connector, Flat Ribbon Cable, PC Wiring System [IP40/67] ······························ Page 81
Flat Terminal
ribbon cable block box Terminal Block Box [IP67] ······························································································· Page 99

Metal Base
Lead wire Circular Lead Wire [IP67] ············································································································ Page 109
connector

Plug-in
Circular Connector [IP67] ······························································································ Page 119
EX500
EX500 Gateway-type Serial Transmission System [IP67] ·········································· Page 129
EX600

Manifold Exploded View


Type 50, 51, 52
EX600 Integrated-type (For Input/Output) Serial Transmission System (Fieldbus System) [IP67] ····Page 137
EX250

EX260 EX250 Integrated-type (For Input/Output) Serial Transmission System [IP67] ··········Page 149

EX260 Integrated type (For Output) Serial Transmission System [IP67] ··················· Page 157
EX126

Connector Connecting Base


EX126 Integrated-type (For Output) Serial Transmission System [IP67] ··················· Page 165
EX120
EX120 Integrated-type (For Output) Serial Transmission System [IP20] ··················· Page 173

Type 10/Side ported Common Dimensions


(External Pilot, Silencer, Elbow Fittings, Slide Locking Manual Override) ················ Page 181

Plug-in
Type 11/Bottom Ported Common Dimensions ··························································· Page 184

Manifold Exploded View


Type 10, 11, 12
Type 12/Top Ported Common Dimensions ································································ Page 186

Mixed
mounting
Plug-in Manifold Mixed Mounting Type ······································································· Page 189

Manifold Exploded View [Exploded View, Manifold Parts No.] ··································· Page 206
Plug Assembly Part No.
One-touch Fittings/

How to Increase Connector Type Manifold ································································ Page 219

One-touch Fittings, Plug Assembly/Part No. ··························································································································· Page 224


Manifold Options

Manifold Options [ Plug-in Metal Base, Plug-in Connector Connecting Base] ································································ Page 225

Specific Product Precautions ··················································································································································· Page 242

Front matter 2
Optimum Actuation Size Chart of Air Cylinder
Applicable Applicable cylinder
Main valve
cylinder Series
seal type
speed ø6 ø10 ø16 ø20 ø25

SY3000

Rubber seal SY5000

SY7000
100 mm/s
or less
SY3000

Metal seal SY5000

SY7000

SY3000

Rubber seal SY5000

SY7000
300 mm/s
or less
SY3000

Metal seal SY5000

SY7000

SY3000

Rubber seal SY5000

SY7000
500 mm/s
or less
SY3000

Metal seal SY5000

SY7000
[Common conditions]
• Pressure: 73 psi (0.5 MPa)
• Piping length: 1 m
• Load ratio: 50%
• Stroke: 200 mm
Connector type manifold (for side and bottom ported type)
∗ Use as a guide for selection.
Please check the actual conditions with SMC Model Selection Software.

1
ø32
ø40
ø50
ø63
ø80
Applicable cylinder

ø100
ø125
ø140
ø160

2
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Series SY3000/5000/7000
Valve Specifications
Valve Specifications

Valve type Rubber seal Metal seal


Fluid Air
2-position single 22 to 102 (0.15 to 0.7)
Internal pilot 2-position double 0.1 to 0.7 (High pressure type: 0.1 to 1)
15 to 102 (0.1 to 0.7)
operating pressure range
psi (MPa) 3-position 29 to 102 (0.2 to 0.7)
4-position dual 3-port valve 22 to 102 (0.15 to 0.7) —
–15 to 102 (–100 kPa to 0.7) –15 to 102 (–100 kPa to 0.7)
Operating pressure range
(4-position: –15 to 87 (–100 kPa to 0.6)) (High pressure type: –15 to 145 (–100 kPa to 1))
External pilot 2-position single
15 to 102 (0.1 to 0.7)
operating pressure range Pilot 2-position double 36 to 102 (0.25 to 0.7)
psi (MPa) (High pressure type: 15 to 145 (0.1 to 1))
pressure 3-position
range Operating pressure + 15 (0.1) or more
4-position dual 3-port valve —
(Min. 36 (0.25)) to 102 (0.7)
Ambient and fluid temperature °F (°C) 14 to 122 (–10 to 50) (No freezing)
2-position single/double
SY3000 5 20 Note 1)
4-position dual 3-port valve
SY5000
Max. operating frequency 3-position 3 10 Note 1)
(Hz) 2-position single/double 5 10 Note 1)
SY7000 4-position dual 3-port valve 3 —
3-position 3 10 Note 1)
Non-locking push type
Push-turn locking slotted type
Manual override
Push-turn locking lever type
Slide locking type
Internal pilot Main/Pilot valve common exhaust Main/Pilot valve individual exhaust
Pilot exhaust type
External pilot Pilot valve individual exhaust
Lubrication Not required
Single: Unrestricted
Mounting orientation Note 2) Unrestricted
Double/3-position: Main valve is horizontal.
Impact/Vibration resistance Note 2) (m/s2) 150/30
Enclosure IP67 (Based on IEC60529)∗
Coil rated voltage (DC) 24, 12 V
Allowable voltage fluctuation (V) ±10% of rated voltage Note 3)
Standard 0.35 (With indicator light: 0.4)
High pressure type, Quick response type 0.9 (With indicator light: 0.95)
Power consumption (W)
Standard: 0.1 Note 4) (With indicator light only) [Inrush 0.35, Holding 0.1],
With power saving circuit
High pressure type: 0.4 Note 4) (With indicator light only) [Inrush 0.9, Holding 0.4]
Surge voltage suppressor Diode (Varistor for non-polar type)
Indicator light LED
∗ In the case of a metal seal, there are restrictions in the operating environment. Refer to the Specific Product Precautions (page 242).
Note 1) Use below 5 Hz for with the power saving circuit.
Note 2) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right angles to the main valve and armature in both energized and
de-energized states every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in
the axial direction and at the right angles to the main valve and armature. (Values at the initial period)
Refer to page 247 for the fixation of DIN rail mounting type manifold.
Note 3) Due to voltage drops by the internal circuit in S/Z type and T type (with power saving circuit), use within the allowable voltage fluctuation as follows.
24 VDC: –7% to +10% 24 VDC: –8% to +10%
S/Z type T type
12 VDC: –4% to +10% 12 VDC: –6% to +10%
Note 4) For details, refer to page 244.

3
Valve Specifications Series SY3000/5000/7000

Valve
Response Time

Sub-plate
Response time (ms)
Standard Quick response type
Series Seal type Model Type of actuation Without light/ With light/surge Without light/ With light/surge
surge voltage voltage suppressor surge voltage voltage suppressor

Plug-in
suppressor S/Z type R/U type suppressor S/Z type R/U type
Rubber seal SY310 15 or less 20 or less 15 or less 12 or less 15 or less 12 or less
2-position single
Metal seal SY311 15 or less 20 or less 15 or less 12 or less 15 or less 12 or less
Rubber seal SY320 12 or less 15 or less 12 or less 10 or less 13 or less 10 or less
2-position double
SY3000 Metal seal SY321 12 or less 15 or less 12 or less 10 or less 13 or less 10 or less
Rubber seal SY33/4/50 18 or less 22 or less 18 or less 14 or less 18 or less 14 or less
3-position
Metal seal SY33/4/51 18 or less 22 or less 18 or less 14 or less 18 or less 14 or less

Metal Base
Rubber seal SY3A/B/C0 4-position dual 3-port valve 18 or less 22 or less 18 or less 15 or less 19 or less 15 or less
Rubber seal SY510 24 or less 31 or less 24 or less 18 or less 25 or less 18 or less
2-position single
Metal seal SY511 24 or less 31 or less 24 or less 18 or less 25 or less 18 or less
Rubber seal SY520 12 or less 15 or less 12 or less 10 or less 13 or less 10 or less
2-position double

Plug-in
SY5000 Metal seal SY521 12 or less 15 or less 12 or less 10 or less 13 or less 10 or less
Rubber seal SY53/4/50 30 or less 34 or less 30 or less 24 or less 28 or less 24 or less
3-position
Metal seal SY53/4/51 28 or less 30 or less 28 or less 23 or less 25 or less 23 or less
Rubber seal SY5A/B/C0 4-position dual 3-port valve 35 or less 42 or less 35 or less 28 or less 35 or less 28 or less
Rubber seal SY710 47 or less 58 or less 53 or less 42 or less 52 or less 44 or less

Manifold Exploded View


2-position single
SY711

Type 50, 51, 52


Metal seal 39 or less 48 or less 39 or less 34 or less 43 or less 34 or less
Rubber seal SY720 18 or less 19 or less 19 or less 18 or less 17 or less 17 or less
2-position double
SY7000 Metal seal SY721 17 or less 17 or less 16 or less 16 or less 16 or less 16 or less
Rubber seal SY73/4/50 52 or less 54 or less 47 or less 42 or less 46 or less 40 or less
3-position
Metal seal SY73/4/51 38 or less 45 or less 39 or less 33 or less 38 or less 34 or less
Rubber seal SY7A/B/C0 4-position dual 3-port valve 52 or less 60 or less 54 or less 49 or less 53 or less 48 or less

Connector Connecting Base


Plug-in
Manifold Exploded View
Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

4
Series SY3000/5000/7000
Valve Weight
Series SY3000
Valve model Seal type Type of actuation Weight g Valve model Seal type Type of actuation Weight g
Single 74 Single 76
2-position 2-position
Double 83 Double 86
Closed center SY301 Metal seal Closed center
SY300 Rubber seal
3-position Exhaust center 87 3-position Exhaust center 90
Pressure center Pressure center
4-position Dual 3-port valve 83

Seal Port size Weight Seal Port size Weight


Valve model Type of actuation Valve model Type of actuation
type 4, 2 (A, B) g type 4, 2 (A, B) g
Single 74 Single 76
2-position 2-position
Double 83 Double 86
SY330-M5 Closed center
M5 x 0.8
SY331-M5 Closed center M5 x 0.8
3-position Exhaust center 87 3-position Exhaust center 90
Pressure center Pressure center
4-position Dual 3-port valve 83 Single 84
2-position
Single 82 Double C2 94
2-position
Double
C2
91 SY331-C2 Closed center ø2 One-touch
Closed center 3-position Exhaust center fitting 98
SY330-C2 ø2 One-touch
3-position Exhaust center 95 Pressure center
fitting
Pressure center Single 87
2-position
4-position Dual 3-port valve 91 Double C3 97
Metal
Single 85 SY331-C3 seal Closed center ø3.2 One-touch
2-position
Double 94 3-position Exhaust center fitting 101
C3
Rubber Closed center Pressure center
SY330-C3 ø3.2 One-touch
seal 3-position Exhaust center 98 Single 79
fitting 2-position
Pressure center Double C4 89
4-position Dual 3-port valve 94 SY331-C4 Closed center ø4 One-touch
Single 77 3-position Exhaust center fitting 93
2-position
Double 86 Pressure center
C4
Closed center Single 82
SY330-C4 ø4 One-touch 2-position
3-position Exhaust center 90 Double C6 92
fitting
Pressure center SY331-C6 Closed center ø6 One-touch
4-position Dual 3-port valve 86 3-position Exhaust center fitting 96
Single 80 Pressure center
2-position
Double 89
C6
Closed center
SY330-C6 ø6 One-touch
3-position Exhaust center 93
fitting
Pressure center
4-position Dual 3-port valve 89

Series SY5000
Valve model Seal type Type of actuation Weight g Valve model Seal type Type of actuation Weight g
Single 82 Single 91
2-position 2-position
Double 90 Double 101
Closed center SY501 Metal seal Closed center
SY500 Rubber seal
3-position Exhaust center 3-position Exhaust center
100 111
Pressure center Pressure center
4-position Dual 3-port valve 90

Seal Port size Weight Seal Port size Weight


Valve model Type of actuation Valve model Type of actuation
type 4, 2 (A, B) g type 4, 2 (A, B) g
Single 102 Single 111
2-position 2-position
Double 110 Double 121
Closed center SY531-01 Closed center 1/8
SY530-01 3-position Exhaust center
1/8
Exhaust center
120 3-position 131
Pressure center Pressure center
4-position Dual 3-port valve 110 Single 124
2-position
Single 115 Double C4 134
2-position
Double
C4
123 SY531-C4 Closed center ø4 One-touch
Closed center 3-position Exhaust center fitting 144
SY530-C4 3-position Exhaust center
ø4 One-touch
Metal Pressure center
133
fitting
Pressure center seal Single 120
2-position
Rubber 4-position Dual 3-port valve 123 Double C6 130
seal
2-position
Single 110 SY531-C6 Closed center ø6 One-touch
Double 118 3-position Exhaust center fitting 140
C6
Closed center Pressure center
SY530-C6 3-position Exhaust center
ø6 One-touch
Single
128 108
fitting 2-position
Pressure center Double C8 118
4-position Dual 3-port valve 118 SY531-C8 Closed center ø8 One-touch
Single 99 3-position Exhaust center fitting 128
2-position
Double 107 Pressure center
C8
Closed center
SY530-C8 3-position Exhaust center
ø8 One-touch
117
fitting
Pressure center
4-position Dual 3-port valve 107

5
Valve Specifications Series SY3000/5000/7000

Valve
Valve Weight
Series SY7000
Valve model Seal type Type of actuation Weight g Valve model Seal type Type of actuation Weight g
Single 110 Single 122
2-position 2-position
Double 118 Double 133
SY701

Sub-plate
Closed center Metal seal Closed center
SY700 Rubber seal
3-position Exhaust center 133 3-position Exhaust center 150
Pressure center Pressure center
4-position Dual 3-port valve 114

Plug-in
Seal Port size Weight Seal Port size Weight
Valve model Type of actuation Valve model Type of actuation
type 4, 2 (A, B) g type 4, 2 (A, B) g
Single 125 Single 136
2-position 2-position
Double 133 Double 148
SY730-02 Closed center
1/4
SY731-02 Closed center 1/4
3-position Exhaust center 147 3-position Exhaust center 164
Pressure center Pressure center
4-position Dual 3-port valve 129 Single 174
2-position
Single 163 Double C6 186
2-position
SY731-C6

Metal Base
Double 171 Closed center ø6 One-touch
C6
Closed center 3-position Exhaust center fitting 202
SY730-C6 ø6 One-touch
3-position Exhaust center 186 Pressure center
fitting
Pressure center Single 162
2-position
4-position Dual 3-port valve 167 Double C8 174
Metal
Single 151 SY731-C8 Closed center ø8 One-touch

Plug-in
2-position seal
Double 159 3-position Exhaust center fitting 190
C8
Rubber Closed center Pressure center
SY730-C8 seal ø8 One-touch
3-position Exhaust center 174 Single 148
fitting 2-position
Pressure center Double C10 159
4-position Dual 3-port valve 155 SY731-C10 Closed center ø10 One-touch
Single 136 3-position Exhaust center fitting 176

Manifold Exploded View


2-position
Double 144 Pressure center
C10

Type 50, 51, 52


Closed center Single 157
SY730-C10 ø10 One-touch 2-position
3-position Exhaust center 159 Double C12 169
fitting
Pressure center SY731-C12 Closed center ø12 One-touch
4-position Dual 3-port valve 140 3-position Exhaust center fitting 185
Single 146 Pressure center
2-position
Double 154
C12
Closed center
SY730-C12 ø12 One-touch
3-position Exhaust center 169
fitting
Pressure center

Connector Connecting Base


4-position Dual 3-port valve 150

Plug-in
Manifold Exploded View
Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

6
Series SY3000/5000/7000
Valve Construction
Rubber Seal
2-position single Top ported
(A) (B)
4 2

t e q w r t e q w r

2-position single
5 4 1 2 3 5 1 3 (A)4 2(B)
(EA) (A) (P) (B) (EB) (EA) (P) (EB)

(EA)5 1 3(EB)
(P)

2-position double
t e q w r

2-position double
5 4 1 2 3 (A)4 2(B)
(EA) (A) (P) (B) (EB)

(EA)5 1 3(EB)
(P)

3-position closed center/exhaust center/pressure center


t e q w r 3-position closed center 3-position exhaust center
(A)4 2(B) (A)4 2(B)

(EA)5 1 3(EB) (EA)5 1 3(EB)


(P) (P)

3-position pressure center


(A)4 2(B)
5 4 1 2 3
(EA) (A) (P) (B) (EB)

(EA)5 1 3(EB)
(P)

Component Parts
No. Description Material Note
SY3000: Zinc die-casted
1 Body
SY5000/SY7000: Aluminum die-casted
Special resin/HNBR

( )
2 Spool valve 3-position valve:
Aluminum/HNBR
3 Piston Resin
Body cover assembly Resin For side/bottom ported
SY3000: Resin
4
Port block assembly SY5000: Zinc die-casted For top ported
SY7000: Aluminum die-casted
5 Pilot valve assembly — Refer to page 12.

7
Valve Construction Series SY3000/5000/7000

Valve
Rubber Seal
4-position dual 3-port valve
4-position dual 3-port valve
N.C. valve x 2 pcs. N.O. valve x 2 pcs.
t e q w r 4(A) 2(B) 4(A) 2(B)

Sub-plate
Plug-in
5(EA) 1(P) 3(EB) 5(EA) 1(P) 3(EB)
N.C. valve, N.O. valve 1 pc. of each
5 4 1 2 3 4(A) 2(B)
(EA) (A) (P) (B) (EB)

Metal Base
5(EA) 1(P) 3(EB)

2-position double with back pressure check valve (Built-in valve type)

Plug-in
t e q w r
2-position double
with back pressure check valve
(A)4 2(B)

Manifold Exploded View


Type 50, 51, 52
(EA)5 1 3(EB)
(P)
5 4 1 2 3
(EA) (A) (P) (B) (EB)
∗ The built-in valve type back pressure check valve is not available for the SY7000.

Connector Connecting Base


4-position dual 3-port valve with back pressure check valve (Built-in valve type)

4-position dual 3-port valve with back pressure check valve


t e q w r N.C. valve x 2 pcs. N.O. valve x 2 pcs.
4(A) 2(B) 4(A) 2(B)

Plug-in
Manifold Exploded View
Type 10, 11, 12
5(EA) 1(P) 3(EB) 5(EA) 1(P) 3(EB)
5 4 1 2 3 N.C. valve, N.O. valve 1 pc. of each
(EA) (A) (P) (B) (EB)
4(A) 2(B)
Plug Assembly Part No.
One-touch Fittings/

5(EA) 1(P) 3(EB)

∗ The built-in valve type back pressure check valve is not available for the SY7000.
Manifold Options

8
Series SY3000/5000/7000
Metal Seal
2-position single Top ported
(A) (B)
4 2

t e q w r t e q w r

2-position single
5 4 1 2 3 5 1 3 (A)4 2(B)
(EA) (A) (P) (B) (EB) (EA) (P) (EB)

(EA)5 1 3(EB)
(P)

2-position double
t e q w r

2-position double
5 4 1 2 3 (A)4 2(B)
(EA) (A) (P) (B) (EB)

(EA)5 1 3(EB)
(P)

3-position closed center/exhaust center/pressure center


t e q w r

3-position closed center 3-position exhaust center


(A)4 2(B) (A)4 2(B)

(EA)5 1 3(EB) (EA)5 1 3(EB)


(P) (P)
5 4 1 2 3
(EA) (A) (P) (B) (EB) 3-position pressure center
(A)4 2(B)

(EA)5 1 3(EB)
(P)

Component Parts
No. Description Material Note
SY3000: Zinc die-casted
1 Body
SY5000/SY7000: Aluminum die-casted
2 Spool, Sleeve Stainless steel/HNBR
3 Piston Resin
Body cover assembly Resin For side/bottom ported
SY3000: Resin
4
Port block assembly SY5000: Zinc die-casted For top ported
SY7000: Aluminum die-casted
5 Pilot valve assembly — Refer to page 12.

9
10
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Series SY3000/5000/7000
Valve Replacement Parts
How to Order Port Block Assembly
Mounting screw

SY 0V 6A One-touch fitting

Series Thread type


3 3000 Nil Rc
5 5000 F G
7 7000 N NPT
T NPTF
Pilot type ∗ Except M5
Nil Internal pilot
A, B port size
R External pilot Thread piping
Symbol Port size Applicable series
Option for mounting M5 M5 x 0.8 SY3000
Nil Standard (Valve mounting screw 01 1/8 SY5000
“not” falling-out-prevention type)
02 1/4 SY7000
Valve mounting screw
1 falling-out-prevention type Metric size (One-touch fitting)
Applicable series
Symbol Port size
SY3000 SY5000 SY7000
C2 ø2  — —
C3 ø3.2  — —
C4 ø4   —
C6 ø6   
C8 ø8 —  
C10 ø10 — — 
C12 ø12 — — 
Inch size (One-touch fitting)
Applicable series
Symbol Port size
SY3000 SY5000 SY7000
N1 ø1/8"  — —
N3 ø5/32"   —
N7 ø1/4"   
N9 ø5/16" —  
N11 ø3/8" — — 

 Possible to replace only the One-touch fitting.


Port size SY3000 SY5000 SY7000
ø2 VVQ1000-50A-C2 — —
ø3.2 VVQ1000-50A-C3 — —
ø4 VVQ1000-50A-C4 VVQ1000-51A-C4 —
Metric size ø6 VVQ1000-50A-C6 VVQ1000-51A-C6 VVQ2000-51A-C6
ø8 — VVQ1000-51A-C8 VVQ2000-51A-C8
ø10 — — VVQ2000-51A-C10
ø12 — — KQ2H12-17-X899
ø1/8" VVQ1000-50A-N1 — —
ø5/32" VVQ1000-50A-N3 VVQ1000-51A-N3 —
Inch size ø1/4" VVQ1000-50A-N7 VVQ1000-51A-N7 VVQ2000-51A-N7
ø5/16" — VVQ1000-51A-N9 VVQ2000-51A-N9
ø3/8" — — VVQ2000-51A-N11

Refer to pages 247 and 248 for how to replace


the port block assembly, One-touch fitting and
body cover assembly.

11
Valve Replacement Parts Series SY3000/5000/7000

Valve
Body Cover Assembly
∗ Used when the top ported is changed to the side or bottom ported.

Mounting screw

Sub-plate
Part no.
Series Standard (Valve mounting screw Valve mounting screw
“not” falling-out-prevention type) falling-out-prevention type
Internal pilot SY30V-16A SY30V-16A-1

Plug-in
SY3000
External pilot SY30V-16AR SY30V-16AR-1
Internal pilot SY50V-16A SY50V-16A-1
SY5000
External pilot SY50V-16AR SY50V-16AR-1
Internal pilot SY70V-16A SY70V-16A-1
SY7000
External pilot SY70V-16AR SY70V-16AR-1
∗ The part number is not indicated on the product.

Metal Base
Plug-in
How to Order Pilot Valve Assembly (With a gasket and two mounting screws)

V112 A How to replace pilot valves

Manifold Exploded View


Type 50, 51, 52
Pilot valve option Pilot cover assembly Pilot valve assembly
Nil Standard (102 psi (0.7 MPa)) Series Part no.
Quick response type SY3000 SY30V-25A
B (102 psi (0.7 MPa)) SY5000 Gasket
SY50V-25A
SY7000
High pressure type a-side pilot valve
K (145 psi (1.0 MPa))∗ ∗ Pilot cover x 1 + B tight flat
head screw x 1
∗ Only metal seal type is available for the

Connector Connecting Base


high pressure type. (145 psi (1.0 MPa)) w
Pilot cover

Coil type
Nil Standard q
Socket
w
T With power saving circuit
b-side pilot valve
Rated voltage

Plug-in
5 24 VDC B tight flat head screw (M1.7)
Tightening torque: 0.09 lbf·ft (0.12 N·m) Pilot valve mounting screw (M2 x 16.5)
6 12 VDC
Tightening torque: 0.11 lb·ft (0.15 N·m)

Manifold Exploded View


Caution

Type 10, 11, 12


Pilot valve mounting screw (M2 x 25)
1. The coil specification and voltage (including
light/surge voltage suppressor) cannot be Tightening torque: 0.11 lb·ft (0.15 N·m)
changed by changing the pilot valve
assembly. • Loosen B tight flat head screw to remove the pilot cover in the direction indicated by
2. When selecting the coil type with power
saving circuit, it is not possible to change to
the arrow q.
high pressure/power saving circuit type. • Remove the pilot valve mounting screws.
• Remove the pilot valve in the direction indicated by the arrow w.
Plug Assembly Part No.
One-touch Fittings/

∗ Assemble by following the removal procedure in reverse.


Note 1) Ensure the gasket is mounted, and take care not to bend the socket.
Note 2) Be noted for mounting that there are two types of lengths for the pilot valve mounting
screws.
Manifold Options

12
Series SY5000 RoHS

With Residual Pressure Release Valve


Mountable manifold
SS5Y5-50/51 type manifold
SS5Y5-(M)10/11 type manifold
Sub-plate single unit How to Order (With mounting screw)

SY 5 3 0 0 5 U D 1 E
Series       With residual pressure release valve
5 SY5000 E With residual pressure release valve∗
∗ Mounting screw types, hexagon socket head cap
Type of actuation Base mounted screw B and screw falling-out-prevention type K,
3 3-position closed center∗ (Top ported is not available.) H are not available.
∗ Only closed center type is available. Protective class
class  (Mark: )

 Seal type  Rated voltage  Manual override


0 Rubber seal 5 24 VDC Nil: D:
1 Metal seal 6 12 VDC Non-locking Push-turn
∗ The applicable rated voltage varies depending on push type locking slotted
type
 Pilot valve option the manifold wiring type. Refer to the “How to
Order Manifold” pages.
Nil Standard (102 psi (0.7 MPa))
B Quick response type (102 psi (0.7 MPa)) Light/surge voltage suppressor
 and common specification
K∗ High pressure type (145 psi (1.0 MPa))
Surge voltage Common E: F:
∗ Only metal seal type is available for the high pressure type. Symbol With light Push-turn Slide locking
suppressor specification
locking lever type
Nil — —
 Coil type R — Non-polar
type

Nil Standard U 
T With power saving circuit (Continuous duty type) S — Positive

∗ Be sure to select the power saving circuit type when the Z  common
∗ Refer to page 14 for with the safety slide locking
valve is continuously energized for long periods of time. NS — Negative
∗ Be careful of the energizing time when the power saving manual override.
NZ  common
circuit is selected. Refer to page 244 for details.
∗ Only “Z” and “NZ” types are available for with the
power saving circuit.
Symbol
Valve Specifications <When 1(P) port is <When 1(P) port is
not pressurized> pressurized>
Rubber seal Metal seal
Valve construction EXH. EXH.
3-position closed center valve with residual pressure release valve Note 1)
EXH. EXH.
Fluid Air
44 to 102 (0.3 to 0.7) 4 2 4 2
Operating pressure range psi MPa Note 2) 44 to 102 (0.3 to 0.7) (High pressure: 44 to 145 (0.3 to 1))
Weight g 117 128
5 3 5 3
Note 1) Rubber seal is used for the residual pressure release valve. 1 1
Note 2) Internal pilot type only A mechanism is used that exhausts the pressure of the
Note 3) Other specifications are common to the valve specifications on page 3. cylinder port when the P port supply pressure of the 3
position closed center valve is exhausted.
Dimensions
(Light/surge voltage suppressor)
116.6
Manual override 84.5

( ) 39.8 30.7
12.6

Push-turn locking slotted


type: Press, then rotate it.
4(A) port side : Blue
2(B) port side : Yellow
A side indicator (Red) Note 4) Manual override part 2 x ø3.2
Exhausted: Concave (For manifold mounting)
Pressurized: End face EXH port
1.3 15
EXH port

B side indicator (Red) Note 4)


47.6
45.1

Exhausted: Concave
62.3 (For F type)
(For E type: 60.2)

30.1

Pressurized: End face


56.6

Note 4) The indicator shows the pressurization


status. Do not push it.
13
Series SY3000/5000/7000
Made to Order

Valve
Please contact SMC for detailed dimensions, specifications and lead times.

Symbol
1 Main Valve Fluororubber Specification

Sub-plate
-X90
Fluororubber is used for rubber parts of the main valve to allow use in applications such as the following.

Plug-in
· When using a lubricant other than the recommended turbine oil, and there is a possibility of malfunction due to swelling of the spool valve seals.

Applicable valves series SY3 03 0, SY5 03 0, SY7 03 0 (Only rubber seal type)

3 0
SY 5 3 0 1 X90
7

Metal Base
Entry is the same as standard products.
Specifications and performance are the same as standard products.

Plug-in
Symbol
2 With Safety Slide Locking Manual Override -X13

Manifold Exploded View


Type 50, 51, 52
A safety lock is added to the slide locking manual override.
(Refer to Features 4.)
3 00
SY 5 31 G1 X13
7

Connector Connecting Base


Entry is the same as standard products.
Specifications and performance are the same as standard products.

Symbol
3 Metal Seal Valve, Main/Pilot Valve Common Exhaust -X16

Plug-in
This is the type where the exhaust method of the pilot valve is integrated into the exhaust port of the main valve.
3

Manifold Exploded View


0
SY 5 3 1 1 X16
Type 10, 11, 12
7

Entry is the same as standard products.


∗ Note that the response time of the valve becomes slower than standard products.
Please contact SMC for details.
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

14
15
Plug-in
[IP67 Compliant]
Sub-plate Type

16
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Series SY3000/5000
Plug-in Sub-plate Type [IP67 Compliant]
(Side ported, Bottom ported, Top ported)

Plug-in Sub-plate Specifications


Manifold type Plug-in sub-plate
Side ported 1(P), 5(EA)/3(EB) port, 4(A)/2(B) port Side ported
Bottom ported 1(P), 5(EA)/3(EB) port, 4(A)/2(B) port Bottom ported
Piping direction
1(P), 5(EA)/3(EB) port Side ported
Top ported
4(A)/2(B) port Top ported
SUP/EXH port type SUP/EXH individual port [5(EA), 3(EB) individual]
Applicable connector M12 waterproof connector
Internal wiring Positive common, Negative common
SY3000 1/8
Side ported 1(P), 5(EA)/3(EB) port, 4(A)/2(B) port
SY5000 1/4
SY3000 1/8
Bottom ported 1(P), 5(EA)/3(EB) port, 4(A)/2(B) port
Port size SY5000 1/4
SY3000 1/8
1(P), 5(EA)/3(EB) port
Top ported SY5000 1/4
4(A)/2(B) port Compliant with the valve. Note 1)
Enclosure (Based on IEC60529) IP67
Side ported 99
SY3000 Bottom ported 109
Top ported 104
Weight: W [g] Note 2)
Side ported 150
SY5000 Bottom ported 172
Top ported 159
Note 1) Refer to page 3 for valve specifications.
Note 2) The valve and cable weights are not included. To obtain the weight with valves attached, add the valve weights given on page 5.

Plug-in Sub-plate Flow-rate Characteristics


Rubber Seal Metal Seal
Sub-plate Fitting port size 1  4/2 4/2  5/3 Sub-plate Fitting port size 1  4/2 4/2  5/3
Series Series
piping location (P,E) (A,B) C b C b piping location (P,E) (A,B) C b C b
Side ported 01 01 1.8 0.27 1.7 0.26 Side ported 01 01 1.4 0.14 1.3 0.26
SY3000 Bottom ported 01 01 1.7 0.23 1.4 0.27 SY3000 Bottom ported 01 01 1.3 0.13 1.3 0.22
Top ported 01 C6 1.3 0.34 1.5 0.27 Top ported 01 C6 1.2 0.22 1.4 0.29
Side ported 02 02 4.2 0.21 4.0 0.26 Side ported 02 02 3.2 0.13 3.5 0.16
SY5000 Bottom ported 02 02 4.0 0.19 4.0 0.23 SY5000 Bottom ported 02 02 3.0 0.12 3.2 0.17
Top ported 02 C8 2.9 0.29 4.1 0.33 Top ported 02 C8 2.6 0.23 3.2 0.19
∗ Calculation of effective area S and sonic conductance C: S = 5.0 x C
Note) The value is for individually operated 2-position type.

17
Series SY3000/5000
Sub-plate Type [IP67 Compliant]
Plug-in
(Side ported, Bottom ported, Top ported)

Valve
RoHS
How to Order
In the case of Valve + Sub-plate (Built-in valve type part no.)

Sub-plate
SY 3 1 0 0 5 U D 1 C6 W1 01

Plug-in
                 
Light/surge voltage suppressor A, B port thread type
 Series  and common specification  (Top ported valve only)
3 SY3000 Surge voltage Common Nil Rc
Symbol With light
5 SY5000 suppressor specification F G
Nil — — N NPT
 Type of actuation R — Non-polar T NPTF

Metal Base
1 Single U ∗ Only Nil is available for M5.
2-position
2 Double S — Positive
3 Closed center Z
common  Type of mounting screw
4 3-position Exhaust center NS — Negative Nil Round head combination screw
5 Pressure center NZ common B Hexagon socket head cap screw

Plug-in

A∗ N.C./N.C. ∗ Only “Z” and “NZ” types are available for with the K
Round head combination screw
4-position
B∗ dual 3-port N.O./N.O. power saving circuit.
(Falling-out-prevention type)
C∗ N.C./N.O. H Hexagon socket head cap screw
∗ Only rubber seal type is available for the  Manual override (Falling-out-prevention type)
4-position dual 3-port valve. Nil: D: ∗ For “K” and “H”, the valve body cover has a drop

Manifold Exploded View


Non-locking Push-turn prevention construction to stop the mounting
 Valve piping type

Type 50, 51, 52


push type locking screws from falling out when the valve is
0 Base mounted (Port location: Side, Bottom) slotted removed for maintenance etc.
type ∗ When ordering a valve individually, the base
3 Top ported (4A, 2B port location: Top)
gasket is not included. Since the base gasket is
 Seal type attached to the manifold, please order the base
gasket separately if it is needed for maintenance
0 Rubber seal service.
1 Metal seal E: F: Refer to page 19 for part numbers of the base
Push-turn Slide locking gasket and mounting screw.
 Pilot type

Connector Connecting Base


locking lever type ∗ When using an optional spacer assembly, “B”
Nil Internal pilot type and “H” cannot be selected.
R External pilot  Wiring specifications
 Back pressure check valve (Built-in valve type) WO Without M12 connector cable
Nil None W1 With M12 connector cable (300 mm)
H Built-in ∗ Refer to page 14 for with the safety slide locking W2 With M12 connector cable (500 mm)
∗ Only rubber seal type manual override. W3 With M12 connector cable (1000 mm)
∗ The built-in valve type back pressure check W4 With M12 connector cable (2000 mm)

Plug-in
valve is not available for the 3-position type.  A, B port size (∗Top ported valve only) W7 With M12 connector cable (5000 mm)
Thread piping ∗ When ordering a product with M12 connector
 Pilot valve option Symbol Port size Applicable series
cable, the connector cable is included.

Manifold Exploded View


Nil Standard (102 psi (0.7 MPa)) M5 M5 x 0.8 SY3000

Type 10, 11, 12


B Quick response type (102 psi (0.7 MPa)) 01 1/8 SY5000  Port location (Sub-plate)
K∗ High pressure type (145 psi (1.0 MPa))
Nil Side ported
Metric size (One-touch fitting)
∗ Only metal seal type is available for the high B Bottom ported
pressure type. Symbol A, B port SY3000 SY5000
C2 ø2 —
V Top ported (1P, 5EA, 3EB port: Side ported)
 Coil type C3 ø3.2 —  Port size
Nil Standard C4 ø4
Symbol Port size Applicable series
T With power saving circuit (Continuous duty type) C6 ø6
01 1/8 SY3000
∗ Be sure to select the power saving circuit type C8 ø8 —
Plug Assembly Part No.

02 1/4 SY5000
One-touch Fittings/

when the valve is continuously energized for


Inch size (One-touch fitting)
long periods of time.
∗ Be careful of the energizing time when the power Symbol A, B port SY3000 SY5000  Sub-plate thread type
saving circuit is selected. Refer to page 244 for N1 ø1/8" — Nil Rc
details. N3 ø5/32" F G
N7 ø1/4" N NPT
 Rated voltage N9 ø5/16" — T NPTF
Manifold Options

5 24 VDC
6 12 VDC

Note) When mounting a special order (including Made-to-Order specification) valve on the sub-plate, add the valve part number under the sub-plate part number to
place an order. For details, refer to the ordering example on page 19.

18
Series SY3000/5000

How to Order

In the case of Sub-plate (Sub-plate single unit part no.)


∗ Without valve
SY 3 0M 27 1 W1 01
    
 Series  Port location (Sub-plate)  Sub-plate thread type
3 SY3000 Nil Side ported Nil Rc
5 SY5000 B Bottom ported F G
V Top ported [1(P), 5(EA), 3(EB) port: Side ported] N NPT
 Wiring specifications T NPTF
WO Without M12 connector cable  Port size
W1 With M12 connector cable (300 mm) Symbol Port size Applicable series
W2 With M12 connector cable (500 mm) 01 1/8 SY3000
W3 With M12 connector cable (1000 mm) 02 1/4 SY5000
W4 With M12 connector cable (2000 mm)
W7 With M12 connector cable (5000 mm)
Note 1) Refer to the table below for connector How to Order when mounting a special order (including Made-to-Order specification)
cable part numbers. valve on the sub-plate (Ordering example: X90)
Note 2) When ordering a product with M12
connector cable, the connector cable is SY30M-27-1-W1-01·····1 set (Sub-plate single unit part no.)
included. ∗SY3200-5U1-X90 ·········1 set (2-position double part no./Main valve fluororubber specification)

Sub-plate Parts No.

q Part no.
No. Description Note
SY3000 SY5000
Round head SY3000-23-24A SY5000-221-1A
Valve combination screw (M2 x 32) (M3 x 32.5) Part numbers shown on
q mounting the left are for 10 valves
screw Hexagon socket SY3000-222-1A SY5000-222-1A (20 pcs.).
head cap screw (M2 x 32) (M3 x 32.5)
Base gasket Part numbers shown on the
w (for sub-plate) SY30M-11-1A SY50M-11-1A left are for 10 valves (10 pcs.).
ZS-37-L Cable length: 300 mm
w ZS-37-M Cable length: 500 mm
M12 waterproof
e connector cable ZS-37-N Cable length: 1000 mm
ZS-37-P Cable length: 2000 mm
ZS-37-C Cable length: 5000 mm

e Caution
Tightening torque
M2: 0.12 (0.16 N·m) (SY3000)
M3: 0.59 (0.8 N·m) (SY5000)

19
Series SY3000/5000
Plug-in Sub-plate Type [IP67 Compliant]
(Side ported, Bottom ported, Top ported)

Valve
Plug-in Side Ported
Dimensions: Series SY3000 Sub-plate Top Ported
14.5 13.3
SY3001 -1-W-01 (Side ported) For "F" marking 1/8

Sub-plate
(Thread type) [4(A), 2(B) port]

12

19
F

Plug-in
Manual override 83.2

(
Push-turn locking slotted type:
Press, then rotate it. ) 51.1
34.5 8.8 2 x ø3.2
4(A) port side: Blue (For rubber seal) (For mounting)
: Gray (For metal seal)

Metal Base
4A 2B
2(B) port side: Yellow

35.9
32.9
BA
14 A

12 B
PE X
(Light/surge voltage suppressor) 5EA 1P 3EB

10.6
(42.1)

Plug-in
52.2 5.8

11.9
67.9 (15.3)
(For 3-position)
1/8
[1(P) port]

(For E type: 62.2)


(For F type: 64.3)

Manifold Exploded View


1: Brown (Unused) 3: Blue (COM.)

Type 50, 51, 52


58.6
2: White (SOL.b) 4: Black (SOL.a)

28
19.5
17.7

20
Sub-plate side pin arrangement Triangle mark

7.4
(No numeric indication)
M5 x 0.8 M5 x 0.8
COM. (PE: External pilot EXH port) (X: External pilot port)
1/8 11 11 9.5

Connector Connecting Base


3
4 2 [5(EA), 3(EB) port]
28.6 5.2
SOL.a 1 SOL.b
Unused (Without terminal)
Note 1) These figures show the “SY3200-5Z1-WO-01F”.

SY3301 -1--W-V01 (Top ported) Plug

Plug-in
F

Manifold Exploded View


Type 10, 11, 12
(Max. 3)

4A 2B
B A
4 A

2B

PE X
(Light/surge voltage suppressor) 5EA 1P 3EB
Plug Assembly Part No.
One-touch Fittings/

11 15 M5 x 0.8 (For threaded type)


One-touch fitting
[4(A), 2(B) port]
[4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
: ø6, ø1/4"
Manifold Options
(M5 threaded type)
(72.8)
58.6

Note 2) These figures show the “SY3230-5Z1-C6-WO-V01F”.


Note 3) 1 (P), 5 (EA), 3 (EB), X and PE ports are side ported. 20
Series SY3000/5000

Plug-in
Dimensions: Series SY3000 Sub-plate Bottom Ported
SY3001 -1-W-B01 (Bottom ported)
For "F" marking
Plug
(Thread type)

19
F

Manual override 83.2

( )

(Max. 3)
Push-turn locking slotted type: 51.1
Press, then rotate it. 34.5 8.8 2 x ø3.2
4(A) port side: Blue (For rubber seal) (For mounting)
: Gray (For metal seal) 4A 2B
2(B) port side: Yellow

35.9
32.9
B A
14 A

12 B
PE X
(Light/surge voltage suppressor) 5EA 1P 3EB

10.6
(42.1)

52.2 5.8

(Max. 3)

11.9
Sub-plate side pin arrangement 67.9 (15.3)
(No numeric indication) (For 3-position)

COM.

1: Brown (Unused) 3: Blue (COM.) 3

(For E type: 62.2)


(For F type: 64.3)
4 2

2: White (SOL.b) 4: Black (SOL.a) SOL.a 1 SOL.b

58.6
Unused (Without terminal)

28
19.5

20
Panel fitting dimensions
Triangle mark Plug M5 x 0.8
M5 x 0.8 28.6 5.2 (X: External pilot port)
(PE: External pilot EXH port) Plug
32.5
3.7

14.7

13 13 7.5
8.2
3.5

29.5
5 3 1
28.3

34.5 2 x M3
2 x ø3.4 4 2
42.5 1/8
[1(P), 2(A), 4(B), 5(EA), 3(EB) port] Fitting dimensions for panel mounting
14.5 13.3 Refer to panel fitting dimensions
for details.

Note) These figures show the “SY3200-5Z1-WO-B01F”.

21
Series SY3000/5000
Plug-in Sub-plate Type [IP67 Compliant]
(Side ported, Bottom ported, Top ported)

Valve
Plug-in Side Ported
Dimensions: Series SY5000 Sub-plate Top Ported
SY5001 -1-W-02 (Side ported)
For "F" marking 1/4

Sub-plate
46.4 10.8
(Thread type) [4(A), 2(B) port]
M5 x 0.8 18 25 M5 x 0.8
(PE: External pilot EXH port) (X: External pilot port)

15.5

Plug-in
13

17.5
F

Manual override 103.4

(
Push-turn locking slotted type:
Press, then rotate it. ) 2 x ø4.3 71.3

Metal Base
(For mounting) 62 7.4
4(A) port side: Blue (For rubber seal)
: Gray (For metal seal) PE 4A 2B X
2(B) port side: Yellow

32

40
B A
14 A

12 B
(Light/surge voltage suppressor)

Plug-in
5EA 1P 3EB

4
10.6
(42.1)

74.6 3.4

11.9
90.3 (16.6)
(For 3-position)

Manifold Exploded View


Sub-plate side pin arrangement 1/4

Type 50, 51, 52


(No numeric indication) [1(P) port]

(For E type: 62.2)


(For F type: 64.3)
1: Brown (Unused) 3: Blue (COM.) COM.

58.6
2: White (SOL.b) 4: Black (SOL.a)
3
4 2

28
15.5
SOL.a SOL.b

13
1

Unused (Without terminal) Triangle mark


18 18 16

Connector Connecting Base


1/4
[5(EA), 3(EB) port]
Note 1) These figures show the “SY5200-5Z1-WO-02F”.

SY5301 -1--W-V02 (Top ported) Plug

Plug-in
Manifold Exploded View
Type 10, 11, 12
(Max. 3)

For "F" marking


14.5 26.8
(Thread type)
<For 01> PE 4A 2B X
F
B A
4 A

2 B

5EA 1P 3EB

One-touch fitting (16.2) 25.9 1/8 (For threaded type)


Plug Assembly Part No.
One-touch Fittings/

[4(A), 2(B) port] (For threaded type) (For threaded type) [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
ø6, ø1/4"
ø8, ø5/16"
(For 01 threaded type)
(76.7)
(62.3)

Manifold Options

Note 2) These figures show the “SY5230-5Z1-C8-WO-V02F”.


Note 3) 1 (P), 5 (EA), 3 (EB), X and PE ports are side ported.
22
Series SY3000/5000

Plug-in
Dimensions: Series SY5000 Sub-plate Bottom Ported
SY5001 -1-W-B02 (Bottom ported)
For "F" marking
(Thread type) 46.4 10.8
M5 x 0.8 M5 x 0.8
Plug
(PE: External pilot EXH port) (X: External pilot port)

15.5

17.5
F

103.4
Manual override
71.3

(Max. 3)
(Push-turn locking slotted type:
Press, then rotate it. ) 2 x ø4.3
(For mounting)
62 7.4
4(A) port side: Blue (For rubber seal)
: Gray (For metal seal) PE 4A 2B X
2(B) port side: Yellow

(Max. 3)

32

40
B A
14 A

12 B
(Light/surge voltage suppressor) 5EA 1P 3EB

4
10.6
(42.1)

74.6 3.4

11.9
90.3 (16.6)
(For 3-position)

Sub-plate side pin arrangement


(No numeric indication)
1: Brown (Unused) 3: Blue (COM.)

(For E type: 62.2)


(For F type: 64.3)
2: White (SOL.b) COM.
4: Black (SOL.a)

58.6
3
4

28
2

15.5
SOL.a 1 SOL.b
Panel fitting dimensions
Triangle mark Plug
2 x M4
Unused (Without terminal)
2 x ø4.5
Fitting dimensions for panel mounting
Refer to panel fitting dimensions
4.5

32
40

for details.
18 18 16

3.5 57
4

30.5

62
9.5

5 1 3
4 2

1/4 18 25
[1(P), 2(A), 4(B), 5(EA), 3(EB) port]

Note) These figures show the “SY5200-5Z1-WO-B02F”.

23
24
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
25
Plug-in

Bottom ported
Side ported

Top ported
Metal Base

26
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Series SY3000/5000/7000 Type 50, 51, 52
Plug-in Metal Base
Manifold Specifications

D-sub connector Flat ribbon cable Serial wiring


Model PG type S5 type
F type P type PH type
J type (EX510)
Manifold type Plug-in metal base
SUP/EXH port type Common SUP/EXH
2 to 9 stations
All double wiring 2 to 4 stations 2 to 8 stations
Valve stations 2 to 12 stations (J type: 2 to 8 stations)
All single wiring 2 to 12 stations 2 to 8 stations 2 to 12 stations

Flat ribbon cable connector


D-sub connector with strain relief
Conforming to Conforming to MIL-C-83503
Applicable connector —
MIL-C-24308
JIS-X-5101 Socket: 26 pins Socket: 20 pins Socket: 10 pins
MIL type MIL type MIL type
Internal wiring Positive common, Negative common
SY3000 1/8
1(P), 3/5(E) port SY5000 1/4
SY7000 3/8

M5 x 0.8, 1/8
SY3000 ø2 One-touch fitting, ø3.2 One-touch fitting, ø4 One-touch fitting, ø6 One-touch fitting
ø1/8" One-touch fitting, ø5/32" One-touch fitting, ø1/4" One-touch fitting
Port size
1/8, 1/4
4(A), 2(B) port SY5000 ø4 One-touch fitting, ø6 One-touch fitting, ø8 One-touch fitting
ø5/32" One-touch fitting, ø1/4" One-touch fitting, ø5/16" One-touch fitting

1/4
SY7000 ø6 One-touch fitting, ø8 One-touch fitting, ø10 One-touch fitting, ø12 One-touch fitting
ø1/4" One-touch fitting, ø5/16" One-touch fitting, ø3/8" One-touch fitting

Enclosure (Based on IEC60529) IP40 IP20

27
50, 51, 52
Series SY3000/5000/7000
Type

Plug-in Metal Base

Valve
Manifold Flow-rate Characteristics Note 1)/Manifold Weight
Valve Seal Type: Rubber Seal

Sub-plate
Port size Valve flow-rate characteristics Weight: W [g] Note 2)
Model 1, 5, 3 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→E) (n: stations)
(P, EA, EB) (A, B) C [dm3/(s·bar)] b C [dm3/(s·bar)] b Fixed: C Replaceable: KC

Plug-in
SS5Y3-50 (Side ported) 1/8 C6 1.1 0.19 1.1 0.15 39n + 247 43.5n + 247
SS5Y3-51 (Bottom ported) 1/8 C6 1.2 0.31 1.2 0.14 41.5n + 251 48.5n + 251
SS5Y3-52 (Top ported) 1/8 C6 1.1 0.29 1.2 0.20 44n + 247
SS5Y5-50 (Side ported) 1/4 C8 2.6 0.28 2.6 0.14 93n + 379 110n + 379
SS5Y5-51 (Bottom ported) 1/4 C8 2.7 0.35 2.8 0.20 93n + 413 113n + 413
SS5Y5-52 (Top ported) 1/4 C8 2.6 0.26 3.1 0.13 103n + 379

Metal Base
SS5Y7-50 (Side ported) 3/8 C10 3.8 0.27 4.0 0.20 144n + 510 158n + 510
SS5Y7-51 (Bottom ported) 3/8 C10 4.1 0.34 4.8 0.20 150n + 549 172n + 549
SS5Y7-52 (Top ported) 3/8 C10 4.5 0.27 4.9 0.24 164n + 510

Plug-in
Valve Seal Type: Metal Seal
Port size Valve flow-rate characteristics Weight: W [g] Note 2)
Model 1, 5, 3 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→E) (n: stations)
(P, EA, EB) (A, B) Fixed: C Replaceable: KC

Manifold Exploded View


C [dm3/(s·bar)] b C [dm3/(s·bar)] b

Type 50, 51, 52


SS5Y3-50 (Side ported) 1/8 C6 0.9 0.14 1.0 0.12 39n + 247 43.5n + 247
SS5Y3-51 (Bottom ported) 1/8 C6 1.0 0.21 1.1 0.10 41.5n + 251 48.5n + 251
SS5Y3-52 (Top ported) 1/8 C6 1.1 0.15 1.1 0.14 44n + 247
SS5Y5-50 (Side ported) 1/4 C8 2.2 0.20 2.3 0.13 93n + 379 110n + 379
SS5Y5-51 (Bottom ported) 1/4 C8 2.4 0.26 2.5 0.16 93n + 413 113n + 413
SS5Y5-52 (Top ported) 1/4 C8 2.4 0.18 2.6 0.12 103n + 379

Connector Connecting Base


SS5Y7-50 (Side ported) 3/8 C10 3.2 0.23 3.5 0.18 144n + 510 158n + 510
SS5Y7-51 (Bottom ported) 3/8 C10 3.5 0.25 4.0 0.16 150n + 549 172n + 549
SS5Y7-52 (Top ported) 3/8 C10 3.5 0.21 3.8 0.18 164n + 510
∗ Calculation of effective area S and sonic conductance C: S = 5.0 x C
Note 1) The value is for manifold base with 5 stations and individually operated 2-position type.
Note 2) Weight: W is the value for the D-sub connector manifold.
To obtain the weight with valves attached, add the valve weights given on page 5 for the appropriate number of stations.

Plug-in
Manifold Exploded View
Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

28
Type 50
Side Ported
Plug-in Metal Base RoHS
D-sub Connector Flat Ribbon Cable PC Wiring
Type 51
Bottom Ported
Series SY3000/5000/7000
How to Order Manifold

SS5Y 3 50 F 1 05 D C6
         
 Series  Type  Connector type
3 SY3000 50 Side ported F: D-sub connector P: Flat ribbon cable PG: Flat ribbon cable
5 SY5000 51 Bottom ported (25 pins) (26 pins) (20 pins)
7 SY7000 50R Side ported, External pilot
∗ External pilot is not available for
the bottom ported type.

 Connector entry direction


1: Upward 2: Lateral PH: Flat ribbon cable J: PC wiring
(10 pins) (20 pins)

 Wiring type
Nil All double wiring Note 1)
S All single wiring Note 2)
How to Order Manifold Assembly Note 1) All double wiring: 2-position single, double, 3-position and 4-position
valves can be used on all manifold stations.
Note 2) All single wiring: Available only for the manifold which has 2-position
Example (SS5Y3-50F2-) single for all stations.
2-position double (24 VDC) Note that 2-position double, 3- or 4-position valves cannot be used.
2-position single (24 VDC)
SY3200-5U1 (1 set) Note 3) If a mix of single and double wiring is required, it is supplied as a
SY3100-5U1 (3 sets)
3-position closed special order.
center (24 VDC)
SY3300-5U1 (1 set)

 Valve stations
F: D-sub connector (25 pins) P: Flat ribbon cable (26 pins) PG: Flat ribbon cable (20 pins)
Symbol Stations Note Symbol Stations Note Symbol Stations Note
ide 02 2 stations All 02 2 stations All 02 2 stations All
Us
double double double
s

12 12 stations wiring 12 12 stations wiring 09 9 stations wiring


n
tio
ta
S

Manifold base 02 2 stations All 02 2 stations All 02 2 stations All


3

(5 stations) single single single


2

SS5Y3-50F2-05D-C6
1

ide 12 12 stations wiring 12 12 stations wiring 12 12 stations wiring


Ds
PH: Flat ribbon cable (10 pins) J: PC wiring (20 pins)
SS5Y3-50F2-05D-C6 ···1 set (Type 50 5-station manifold base part no.) Symbol Stations Note Symbol Stations Note
∗SY3100-5U1 ·················3 sets (2-position single part no.) 02 2 stations All 02 2 stations All
∗SY3200-5U1 ·················1 set (2-position double part no.) double double
∗SY3300-5U1 ·················1 set (3-position closed center part no.)
04 4 stations wiring 08 8 stations wiring
The asterisk denotes the symbol for assembly. 02 2 stations All 02 2 stations All
Prefix it to the part numbers of the valve etc.
single single
• The valve arrangement is numbered as the 1st station from the D side. 08 8 stations wiring 12 12 stations wiring
• Under the manifold part number, state the valves to be mounted in order from
∗ This also includes the number of blanking plate assembly.
the 1st station as shown in the figure above. If the arrangement becomes
complicated, specify on a manifold specification sheet.
Note) When mixing top ported configurations, select from page 50.
In this case, use caution as there is also output on the A and B port on base side.
Specify on a manifold specification sheet if plugs are required on the A and B port
on base side.
29
Plug-in Metal Base Series SY3000/5000/7000

Valve
Sub-plate
 P, E port entry  A, B port size

Plug-in
U U side Note 1) Thread piping
D D side Note 1, Note 2) Symbol A, B port SY3000 SY5000 SY7000
B Both sides M5 M5 x 0.8  — —
Note 1) Plugs are mounted on the opposite 01 1/8   —
side of the selected ports. 02 1/4 —  
Note 2) Only D side is available for Type 51
(Bottom ported). One-touch fitting (Metric)

Metal Base
Symbol A, B port SY3000 SY5000 SY7000
 Thread type C2 ø2  — —

Nil Rc C3 ø3.2  — —
F G C4 ø4   —
Fixed

Plug-in
N NPT C6 ø6   —
T NPTF C8 ø8 —  
C10 ø10 — — 
 Mounting KC2 ø2  — — Type 50 Type 51
Nil Direct mounting KC3 (Side ported) (Bottom ported)

Manifold Exploded View


ø3.2  — —
D

Type 50, 51, 52


DIN rail mounting (With DIN rail) KC4 ø4   —
Replaceable

D0 DIN rail mounting (Without DIN rail)


KC6 ø6   
D3 For 3 stations
Specify a longer rail than KC8 ø8 —  
···

···

the standard length.


D12 For 12 stations KC10 ø10 — — 
Note 1) Only direct mounting is available for Type KC12 ø12 — — 
51 (Bottom ported).
Note 2) Refer to page 247 for the fixation of DIN
M∗ Mixed sizes   
P, E port size (Thread piping) 1/8 1/4 3/8

Connector Connecting Base


rail mounting type manifold.
One-touch fitting (Inch)
Symbol A, B port SY3000 SY5000 SY7000
N1 ø1/8"  — —
N3 ø5/32"   —
Fixed

N7 ø1/4"   —
N9 ø5/16" —  
N11 ø3/8" — — 

Plug-in
KN1 ø1/8"  — — Type 50 Type 51
(Side ported) (Bottom ported)
KN3 ø5/32"   —
Replaceable

Manifold Exploded View


KN7 ø1/4"   

Type 10, 11, 12


KN9 ø5/16" —  
KN11 ø3/8" — — 
M∗ Mixed sizes   
P, E port size (Thread piping) 1/8 1/4 3/8
∗ When ports are mixed sizes, indicate the piping specifications on the
manifold specification sheet.
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

Protective class
class III (Mark: )

30
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 0 0 5 1
          
Base mounted

 Series  Pilot valve option  Manual override


3 SY3000 Nil Standard (102 psi (0.7 MPa)) Nil: D:
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Non-locking Push-turn
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa)) push type locking
∗ Only metal seal type is available for the high slotted type
pressure type.
 Type of actuation
1
2-position
Single  Coil type
2 Double Nil Standard E: F:
3 Closed center T With power saving circuit (Continuous duty type) Push-turn Slide locking
4 3-position Exhaust center
∗ Be sure to select the power saving circuit type
locking lever type
5 Pressure center type
when the valve is continuously energized for
A∗ N.C./N.C. long periods of time.
4-position
B∗ dual 3-port N.O./N.O. ∗ Be careful of the energizing time when the power
C∗ N.C./N.O. saving circuit is selected. Refer to page 244 for
details.
∗ Only rubber seal type is available for the
4-position dual 3-port valve. ∗ Refer to page 14 for with the safety slide locking
manual override.
 Rated voltage
5 24 VDC
 Seal type 6 12 VDC  Type of mounting screw
0 Rubber seal
Nil Round head combination screw
1 Metal seal
B Hexagon socket head cap screw
 Light/surge voltage suppressor K
Round head combination screw
(Falling-out-prevention type)
and common specification
 Pilot type Surge voltage Common H
Hexagon socket head cap screw
Symbol With light (Falling-out-prevention type)
Nil Internal pilot suppressor specification
R External pilot ∗ For “K” and “H”, the valve body cover has a drop
Nil — —
prevention construction to stop the mounting screws
R — Non-polar from falling out when the valve is removed for
U  maintenance etc.
 Back pressure check valve S —

Positive ∗ When ordering a valve individually, the base gasket is
(Built-in valve type) Z  common not included. Since the base gasket is attached to the
NS — Negative manifold, please order the base gasket separately if it
Nil None is needed for maintenance service.
H Built-in NZ  common
Refer to page 73 for part numbers of the base gasket
∗ Only rubber seal type ∗ Only “Z” and “NZ” types are available for with the and mounting screw.
∗ Back pressure check valve is not available for power saving circuit. ∗ “B” and “H” cannot be selected for the individual
the 3-position type and the SY7000. SUP/EXH spacer assembly, interface regulator or
double check spacer assembly with residual pressure
release valve.

Protective class
class ΙΙΙ (Mark: )

31
Plug-in Metal Base Series SY3000/5000/7000

Valve
Plug-in Type 50/Side Ported

Dimensions: Series SY3000 Metal Base D-sub Connector

U M5 D side U side
SS5Y3-50(R)F 12 - Stations D - KC
C, N (D)
, KN L3

Sub-plate
B
5.3 L4
(DIN rail mounting hole pitch: 12.5)
Manual override
(Pitch)
JIS-X-5101
( ) DIN rail holding screw 45.1 P = 10.5 (
Push-turn locking slotted type:
)

Plug-in
Applicable connector: D-sub equivalent Press, then rotate it.
MIL-C-24308 (For DIN rail mounting)
14 24.1 4(A) port side : Blue (For rubber seal)
(Light/surge : Gray (For metal seal)
M5 x 0.8 (External pilot) DIN rail bracket mounting screw (7.9) voltage 2(B) port side : Yellow
[Pilot EXH port] (For DIN rail mounting) suppressor)

DIN rail

(Connector entry
upward direction) B A B A B A B A B A

92.7

Metal Base
14 A 14 A 14 A 14 A 14 A

89
PE
5EA
16.8 17.2
15.9 16.2
79

5.5
64.4

35

56.9
21.8 16
1P
29.8

35

26.6
X

12 B 12 B 12 B 12 B 12 B
3EB

4 x ø4.5

Plug-in
8.6 2 x M2.6
(For mounting) 4 L2 8
)

2 x 4-40 UNC
Replaceable: 7.7

14.5 (L5)
[For N or T thread] L1
22.1
Fixed: 4.1

6.1 (Station 1) --- (Station n)


28

Manifold Exploded View


1/8

manual override)

Type 50, 51, 52


(

(Slide locking
[1(P), 5(EA), 3(EB) port]
(68.7)

68.3
62.6
M5 x 0.8 (External pilot)
54.7

2B 2B
[External pilot port]

7.1

32
22.6
4A 4A

50RF12 - Stations UD

(For DIN rail


mounting)
C2, C3: 5.4

7.5

Connector Connecting Base


11.8
3 C4, C6: 6.6
[Plug for external pilot] C2, C3: 42.4 (Pitch)
2B
C4, C6: 41.8 P = 10.5 One-touch fitting
4A [4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
∗ The above drawing shows when P, E : ø6, ø1/4"
port entry is D.
Note) These figures show the “SS5Y3-50F2-05B-C6”.

Plug-in
Port size M5 One-touch fitting (Replaceable)

Manifold Exploded View


Type 10, 11, 12
2B 2B
7.1

7.1
32

32
22.6

22.6

4A 4A

M5 x 0.8
6.6 (Pitch)
[4(A), 2(B) port] P = 10.5
(Pitch) 48.4
41.8 P = 10.5
Plug Assembly Part No.

One-touch fitting
One-touch Fittings/

[4(A), 2(B) port]


Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
: ø6, ø1/4"

n: Stations 2 3 4 5 6 7 8 9 10 11 12
Manifold Options

L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17

32
Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Dimensions: Series SY3000 Metal Base D-sub Connector

U
SS5Y3-50(R)F 12 - Stations -D01(D)
B
D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5)
Manual override
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308
equivalent ) DIN rail holding screw 45.1
(Pitch)
P = 12.5 (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 14 24.1
M5 x 0.8 (External pilot) 4(A) port side : Blue (For rubber seal)
(Light/surge
DIN rail bracket mounting screw (7.9) : Gray (For metal seal)
[Pilot EXH port] voltage
suppressor) 2(B) port side : Yellow
(For DIN rail mounting)

DIN rail

(Connector entry B A B A B A B A B A

upward direction)

92.7
14 A 14 A 14 A 14 A 14 A
5EA

89
PE
16.8 17.2
15.9 16.2
79

5.5
64.4

35

56.9
21.8 16
1P
29.8

35
X

26.6
12 B 12 B 12 B 12 B 12 B
3EB

8.6 2 x M2.6 4 x ø4.5 4 L2 8


2 x 4-40 UNC (For mounting)
14.5 [For N or T thread] (L5) L1
22.1
(Station 1) ------ (Station n)
28 6.1

1/8

manual override)
(Slide locking
[1(P), 5(EA), 3(EB) port]
(68.7)

68.3
62.6
M5 x 0.8 (External pilot)
54.7

2B 2B
[External pilot port]
7.1

32
22.6
4A 4A

(For DIN rail


6.6

mounting)
7.5
(Pitch)
50RF 12 - Stations U
D 1/8
11.8
41.8 P = 12.5
[4(A), 2(B) port]

3
[Plug for external pilot]
2B
Note) These figures show the “SS5Y3-50F2-05B-01”.
4A

∗ The above drawing shows when P, E


port entry is D.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5
L4 100 112.5 125 137.5 150 162.5 175 187.5 200 212.5 225
L5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5

33
Plug-in Metal Base Series SY3000/5000/7000

Valve
Plug-in Type 50/Side Ported

Dimensions: Series SY5000 Metal Base D-sub Connector

U 01
SS5Y5-50(R)F12 - Stations - D C, N
B KC, KN
(D) D side
L3
U side

Sub-plate
5.3 L4 Manual override
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent
DIN rail holding screw
(DIN rail mounting hole pitch: 12.5)
(Pitch) (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 50 P = 16 (Light/surge

Plug-in
4(A) port side : Blue (For rubber seal)
M5 x 0.8 (External pilot) 16 24.1 voltage : Gray (For metal seal)
[Pilot EXH port] DIN rail bracket mounting screw suppressor) 2(B) port side : Yellow
(7.9)
(For DIN rail mounting)

DIN rail

(Connector entry B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
PE
5EA

upward direction)

106.2
5.5
23.2

116.6
96.2

35
20

Metal Base
81.6

20

74.1
1P
24.6
20

52.2

43.8
40.2

3EB

8
30.2
X

12 B 12 B 12 B 12 B 12 B

Plug-in
4 x ø4.5
12.3 (For mounting) 5 L2
)
Replaceable: 8.5

2 x M2.6
18 (L5) L1
2 x 4-40 UNC
[For N or T thread]
Fixed: 4.9

28
6.1 (Station 1) ----------- (Station n)
34

Manifold Exploded View


1/4

Type 50, 51, 52


manual override)
(

(Slide locking
[1(P), 5(EA), 3(EB) port]
(74.7)

M5 x 0.8 (External pilot)

74.3
68.6
60.7

[External pilot port] 2B 2B

7.8

38
27.3
4A
50RF 12 - Stations U 4A
D

10

(For DIN rail


3 8.4

Connector Connecting Base


mounting)
(Pitch)

14.3
[Plug for external pilot] 45.8 P = 16
2B
One-touch fitting
4A [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"
∗ The above drawing shows when P, E
port entry is D. Note) These figures show the “SS5Y5-50F2-05B-C8”.

Plug-in
Port size 01 One-touch fitting (Replaceable)

Manifold Exploded View


Type 10, 11, 12
2B 2B
9.8
7.8

38

38
27.3

27.3

4A 4A

8.4 (Pitch)
(Pitch)
51.6 P = 16
45.8 P = 16
Plug Assembly Part No.

One-touch fitting
One-touch Fittings/

1/8 [4(A), 2(B) port]


[4(A), 2(B) port] Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"

n: Stations 2 3 4 5 6 7 8 9 10 11 12
Manifold Options

L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5

34
Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Dimensions: Series SY5000 Metal Base D-sub Connector

U
SS5Y5-50(R)F 12- Stations D -02(D)
B

D side U side
L3
5.3 L4
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent (DIN rail mounting hole pitch: 12.5) Manual override
DIN rail holding screw
(For DIN rail mounting) 50
(Pitch)
P = 17.5
(
Push-turn locking slotted type:
Press, then rotate it. )
M5 x 0.8 (External pilot) (Light/surge 4(A) port side : Blue (For rubber seal)
[Pilot EXH port] DIN rail bracket mounting screw 16 24.1 voltage : Gray (For metal seal)
(For DIN rail mounting) suppressor) 2(B) port side : Yellow

DIN rail

(Connector entry B A B A B A B A B A
upward direction) 14 A 14 A 14 A 14 A 14 A
PE
5EA

106.2
5.5
23.2

116.6
96.2

35
20
81.6

20

74.1
1P
24.6
20

52.2

43.8
40.2

3EB

8
30.2
X

12 B 12 B 12 B 12 B 12 B

4 x ø4.5
12.3
(For mounting) 5 L2
18 2 x M2.6 (L5) L1
28 2 x 4-40 UNC
[For N or T thread]
34 6.1 (Station 1) ------------- (Station n)

1/4

manual override)
[1(P), 5(EA), 3(EB) port]

(Slide locking
(74.7)

M5 x 0.8 (External pilot)

74.3
68.6
60.7

2B 2B
[External pilot port] 9.8

38
4A 4A 27.3

10

(For DIN rail


8.4 1/4

mounting)
(Pitch)
[4(A), 2(B) port] 14.3
50RF12 - Stations U
D
45.8 P = 17.5

3
[Plug for external pilot]
2B

4A

Note) These figures show the “SS5Y5-50F2-05B-02”.

∗ The above drawing shows when P, E


port entry is D.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 123 135.5 148 173 185.5 210.5 223 235.5 260.5 273 298
L4 112.5 125 137.5 162.5 175 200 212.5 225 250 262.5 287.5
L5 17.5 15 12.5 16 13.5 17.5 15 12.5 16 13.5 17.5

35
Plug-in Metal Base Series SY3000/5000/7000

Valve
Plug-in Type 50/Side Ported

Dimensions: Series SY7000 Metal Base D-sub Connector

U 02
SS5Y7-50(R)F 12 - Stations D - KC
C, N (D)
, KN
D side
L3
U side

Sub-plate
B
5.3 L4

(
JIS-X-5101
Applicable connector: D-sub MIL-C-24308 equivalent ) (DIN rail mounting hole pitch: 12.5)

(Pitch) (
Manual override
Push-turn locking slotted type:
)
DIN rail holding screw Press, then rotate it.
52 P = 19

Plug-in
M5 x 0.8 (External pilot) (For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
16 24.1 (Light/surge voltage : Gray (For metal seal)
PE: Pilot EXH port DIN rail bracket mounting screw
(7.9) suppressor) 2(B) port side: Yellow
(For DIN rail mounting)

(DIN rail)

B A B A B A B A B A
(Connector entry

5.5
14 A 14 A 14 A 14 A 14 A
PE
5EA

upward direction)

116.7
23.8
28

35
102.1

Metal Base
133.2
92.1

84.6
24
1P
23.8

62.6
28.2

49.7
44.1

2 x M2.6 8
3EB
X

2 x 4-40 UNC 32.1 12 B 12 B 12 B 12 B 12 B

[For N or T thread]

NC
NC

Plug-in
18.1 4 x ø4.5
(5.4)

20.9 (For mounting) 5 L2


34.5 (L5) L1
M5 x 0.8 (External pilot)
40.5
X: External pilot port
(Station 1) (Station n)

Manifold Exploded View


3/8 6.1

Type 50, 51, 52


(Slide locking manual override)
[1(P), 5(EA), 3(EB) port]

50RF12 - Stations U
D
(81.2)

78.3
84
2B 2B
67.2

44.5
9.4
3

32.4
4A 4A
[Plug for external pilot]

Connector Connecting Base


2B

(For DIN rail


10
10.8 (Pitch)

mounting)
14.3
4A
46.6 P = 19
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø8, ø5/16"
∗ The above drawing shows when P, : ø10, ø3/8"
E port entry is D.
Note) These figures show the “SS5Y7-50F2-05B-C10”.

Plug-in
Port size 02 One-touch fitting (Replaceable)

Manifold Exploded View


Type 10, 11, 12
2B 2B
44.5

44.5
10.3
9.4
32.4

31.5

4A 4A

10.8 (Pitch)
(Pitch) 55.7 P = 19
46.6 P = 19 (11)
Plug Assembly Part No.

One-touch fitting
One-touch Fittings/

1/4 (22.9) [4(A), 2(B) port]


[4(A), 2(B) port] (For ø12) Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
: ø10, ø3/8"
: ø12

n: Stations 2 3 4 5 6 7 8 9 10 11 12
Manifold Options

L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 123 148 160.5 185.5 198 223 235.5 260.5 273 298 310.5
L4 112.5 137.5 150 175 187.5 212.5 225 250 262.5 287.5 300
L5 15.5 18.5 15.5 18.5 15 18 15 18 14.5 17.5 14.5

36
Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Dimensions: Series SY3000 Metal Base Flat Ribbon Cable

P
U M5
SS5Y3-50(R) PG 1
PH 2 - Stations D - KC
C, N
, KN
(D) B
D side
L3
U side
J
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override
Applicable connector:
26 pins MIL type with strain relief
(Conforming to MIL-C-83503) DIN rail holding screw 45.1
(Pitch)
P = 10.5
(Push-turn locking slotted type:
Press, then rotate it. )
(Light/surge 4(A) port side : Blue (For rubber seal)
(For DIN rail mounting) 14 24.1
M5 x 0.8 (External pilot) Triangle mark : Gray (For metal seal)
voltage
[Pilot EXH port] DIN rail bracket mounting screw (9.9) suppressor) 2(B) port side : Yellow
(For DIN rail mounting)

DIN rail

B A B A B A B A B A
(Connector entry

92.7
PE

14 A 14 A 14 A 14 A 14 A
5EA

89
16.8 17.2
15.9 16.2
79

5.5
upward direction)
64.4

35

56.9
21.8 16
1P
29.8

35
X

26.6
12 B 12 B 12 B 12 B 12 B
3EB

8.6 M5 x 0.8 (External pilot) 4 L2 8


)Replaceable: 7.7

[External pilot port]


14.5 4 x ø4.5 (L5) L1
22.1 1/8 (For mounting)
Fixed: 4.1

[1(P), 5(EA), 3(EB) port] (Station 1) --- (Station n)


28
18
(

50PJG (20 pins)

manual override)
50PH (10 pins)

(Slide locking
(80.6)

Triangle mark

68.3
62.6
Triangle mark
56.7

For PC wiring 2B 2B

7.1

32
22.6
4A 4A

(For DIN rail


mounting)
C2, C3: 5.4

7.5
5EA

5EA
PCW type
PE

PE

11.8
C4, C6: 6.6
1P

1P

C2, C3: 42.4 (Pitch)


X

X
3EB

3EB

C4, C6: 41.8 P = 10.5 One-touch fitting


[4(A), 2(B) port]
Applicable tube O.D.: ø2
Applicable connector: Applicable connector: : ø3.2, ø1/8"
20 pins MIL type with strain relief 10 pins MIL type with strain relief : ø4, ø5/32"
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) : ø6, ø1/4"

Note 1) These figures show the


Port size M5 One-touch fitting (Replaceable)
“SS5Y3-50P2-05B-C6”.
Note 2) Only connectors are different for
50PG, 50PH and 50J.
L1 to L5 dimensions are the
same as 50P type.

2B 2B
50R PJ 12 - Stations UD
7.1

7.1
32

32
22.6

22.6

4A 4A

3
6.6 M5 x 0.8 (Pitch) [Plug for external pilot]
[4(A), 2(B) port] 48.4 P = 10.5 2B
(Pitch)
41.8 P = 10.5 One-touch fitting 4A

[4(A), 2(B) port]


Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32" ∗ The above drawing shows when P, E
: ø6, ø1/4" port entry is D.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17

37
Plug-in Metal Base Series SY3000/5000/7000

Valve
Plug-in Type 50/Side Ported

Dimensions: Series SY3000 Metal Base Flat Ribbon Cable

P
U
PH 2 - Stations D -01(D)
SS5Y3-50(R) PG 1

Sub-plate
J B
D side U side
L3

Applicable connector: 5.3 L4 Manual override

Plug-in
26 pins MIL type with strain relief
(Conforming to MIL-C-83503)
(DIN rail mounting hole pitch: 12.5)
(Pitch) (
Push-turn locking slotted type:
Press, then rotate it. )
DIN rail holding screw 45.1 P = 12.5 4(A) port side : Blue (For rubber seal)
Triangle mark : Gray (For metal seal)
(For DIN rail mounting) 14 24.1 (Light/surge
M5 x 0.8 (External pilot) voltage 2(B) port side : Yellow
[Pilot EXH port] DIN rail bracket mounting screw (9.9) suppressor)
(For DIN rail mounting)
DIN rail

Metal Base
B A B A B A B A B A

92.7
14 A 14 A 14 A 14 A 14 A

89
5EA

PE
16.8 17.2
15.9 16.2
79

5.5
64.4

35

56.9
21.8 16
1P
29.8

35
X

26.6
12 B 12 B 12 B 12 B 12 B

Plug-in
3EB

8.6 4 x ø4.5 4 L2 8
(For mounting)
14.5 (L5) L1
22.1 (Connector entry

Manifold Exploded View


upward direction) (Station 1) ----- (Station n)

Type 50, 51, 52


28
18
1/8

manual override)
[1(P), 5(EA), 3(EB) port]

(Slide locking
(80.6)

68.3
62.6
56.7

M5 x 0.8 (External pilot) 2B 2B


[External pilot port]

7.1

32
22.6
4A 4A

Connector Connecting Base


(For DIN rail
6.6 (Pitch)

mounting)
7.5
50PJG (20 pins) 50PH (10 pins)

11.8
41.8 P = 12.5
1/8
Triangle mark
[4(A), 2(B) port]
For PC wiring Triangle mark

Note 1) These figures show the “SS5Y3-50P2-05B-01”.


Note 2) Only connectors are different for 50PG, 50PH and 50J.
L1 to L5 dimensions are the same as 50P type.

Plug-in
5EA

5EA
PCW type
PE

PE

50R PJ 12 - Stations UD

Manifold Exploded View


1P

1P

Type 10, 11, 12


X

X
3EB

3EB

3
Applicable connector: Applicable connector: [Plug for external pilot]
2B
20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) 4A
Plug Assembly Part No.

∗ The above drawing shows when P, E


One-touch Fittings/

port entry is D.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
Manifold Options

L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193


L3 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5
L4 100 112.5 125 137.5 150 162.5 175 187.5 200 212.5 225
L5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5

38
Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Dimensions: Series SY5000 Metal Base Flat Ribbon Cable

P
U 01
SS5Y5-50(R) PG 1
PH 2 - Stations D - KC
C, N
, KN
(D) B
D side
L3
U side
J
Applicable connector: 5.3 L4
Manual override
26 pins MIL type with strain relief (DIN rail mounting hole pitch: 12.5)
(Conforming to MIL-C-83503)
Triangle mark
DIN rail holding screw
(For DIN rail mounting) 50
(Pitch)
P = 16
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
(Light/surge
M5 x 0.8 (External pilot) 16 24.1 : Gray (For metal seal)
DIN rail bracket mounting screw voltage
[Pilot EXH port] (9.9) suppressor) 2(B) port side : Yellow
(For DIN rail mounting)

DIN rail

B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
(Connector entry
PE
5EA

106.2
5.5
23.2

116.6
upward direction)
96.2

35
20
81.6

20

74.1
1P
24.6
20

52.2

43.8
40.2

8
3EB

30.2
X

12 B 12 B 12 B 12 B 12 B

12.3
L2
)

5
Replaceable: 8.5

18 4 x ø4.5
(L5) L1
28 (For mounting)
Fixed: 4.9

34 M5 x 0.8 (External pilot)


[External pilot port] (Station 1) ----------- (Station n)
1/4 18
[1(P), 5(EA), 3(EB) port]
(

manual override)
50PJG (20 pins) 50PH (10 pins)

(Slide locking
(86.6)

Triangle mark

74.3
Triangle mark

68.6
62.7

2B 2B
For PC wiring

7.8

38
27.3
4A 4A

10

(For DIN rail


8.4
PCW type
PE

PE

(Pitch)

mounting)
5EA

5EA

P = 16

14.3
45.8
1P

1P

One-touch fitting
[4(A), 2(B) port]
3EB

3EB

Applicable tube O.D.: ø4, ø5/32"


X

: ø6, ø1/4"
: ø8, ø5/16"
Note 1) These figures show the “SS5Y5-50P2-05B-C8”.
Applicable connector: Applicable connector:
Note 2) Only connectors are different for 50PG, 50PH and 50J.
20 pins MIL type with strain relief 10 pins MIL type with strain relief
L1 to L5 dimensions are the same as 50P type.
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

Port size 01 One-touch fitting (Replaceable) 50R PJ 12 - Stations UD

3
[Plug for external pilot]
2B

2B
2B 4A
9.8

38
7.8

27.3
38

4A
27.3

4A

One-touch fitting ∗ The above drawing shows when P, E


(Pitch) [4(A), 2(B) port] port entry is D.
8.4 (Pitch)
51.6 P = 16 Applicable tube O.D.: ø4, ø5/32"
45.8 P = 16 : ø6, ø1/4"
1/8 : ø8, ø5/16"
[4(A), 2(B) port]

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5

39
Plug-in Metal Base Series SY3000/5000/7000

Valve
Plug-in Type 50/Side Ported

Dimensions: Series SY5000 Metal Base Flat Ribbon Cable

P
U
PH 2 - Stations D -02(D)
SS5Y5-50(R) PG 1
D side U side

Sub-plate
J B L3
Applicable connector: 5.3 L4 Manual override
26 pins MIL type with strain relief (DIN rail mounting hole pitch: 12.5)
(Conforming to MIL-C-83503) DIN rail holding screw (
Push-turn locking slotted type:
)

Plug-in
(Pitch) Press, then rotate it.
Triangle mark (For DIN rail mounting) 50 P = 17.5 4(A) port side : Blue (For rubber seal)
M5 x 0.8 (External pilot) 16 24.1 (Light/surge : Gray (For metal seal)
DIN rail bracket mounting screw
voltage suppressor) 2(B) port side : Yellow
[Pilot EXH port] (For DIN rail mounting) (9.9)

DIN rail

B A B A B A B A B A

Metal Base
(Connector entry 14 A 14 A 14 A 14 A 14 A
PE
5EA

106.2
5.5
23.2

116.6
upward direction)
96.2

35
20
81.6

20

74.1
1P
24.6
20

52.2

43.8
40.2

3EB

8
30.2
X

12 B 12 B 12 B 12 B 12 B

Plug-in
12.3
5 L2
18
(L5) 4 x ø4.5
M5 x 0.8 (External pilot) L1
28 (For mounting)

Manifold Exploded View


[External pilot port]
34

Type 50, 51, 52


1/4 (Station 1) ------------- (Station n)
[1(P), 5(EA), 3(EB) port] 18

50PJG (20 pins) 50PH (10 pins)

manual override)
(Slide locking
Triangle mark
(86.6)

Triangle mark

74.3
For PC wiring

68.6
62.7

2B 2B

9.8

38
27.3
4A 4A

Connector Connecting Base


10
PCW type
PE

PE
5EA

5EA

(For DIN rail


8.4 1/4

mounting)
(Pitch)
[4(A), 2(B) port]

14.3
45.8 P = 17.5
1P

1P
3EB

3EB
X

Note 1) These figures show the “SS5Y5-50P2-05B-02”.


Note 2) Only connectors are different for 50PG, 50PH and 50J.

Plug-in
Applicable connector: Applicable connector: L1 to L5 dimensions are the same as 50P type.
20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

Manifold Exploded View


50R PJ 12 - Stations UD

Type 10, 11, 12


3
[Plug for external pilot]
2B

4A
Plug Assembly Part No.
One-touch Fittings/

∗ The above drawing shows when P,


E port entry is D.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
Manifold Options

L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 123 135.5 148 173 185.5 210.5 223 235.5 260.5 273 298
L4 112.5 125 137.5 162.5 175 200 212.5 225 250 262.5 287.5
L5 17.5 15 12.5 16 13.5 17.5 15 12.5 16 13.5 17.5

40
Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Dimensions: Series SY7000 Metal Base Flat Ribbon Cable

P
U 02 D side U side
SS5Y7-50(R) PG 1
PH 2 - Stations D - KC
C, N
, KN
(D) B
L3
J 5.3 L4
Applicable connector: Manual override
(DIN rail mounting hole pitch: 12.5)

( )
26 pins MIL type with strain relief Push-turn locking slotted type:
(Conforming to MIL-C-83503) (Pitch)
DIN rail holding screw 52 P = 19 Press, then rotate it.
Triangle mark (For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
16 24.1 (Light/surge voltage : Gray (For metal seal)
M5 x 0.8 (External pilot) DIN rail bracket mounting screw
(9.9) suppressor) 2(B) port side: Yellow
PE: Pilot EXH port (For DIN rail mounting)
(DIN rail)

B A B A B A B A B A

(Connector entry 14 A 14 A 14 A 14 A 14 A
PE
5EA

116.7
upward direction)

5.5
23.8

35
28
102.1

133.2
92.1

84.6
24
1P
23.8

62.6
28.2

49.7
44.1

8
3EB
X

32.1
12 B 12 B 12 B 12 B 12 B

NC
NC
4 x ø4.5
18.1
(5.4)

(For mounting) 5 L2
20.9
M5 x 0.8 (External pilot) (L5) L1
34.5
40.5 X: External pilot port
(Station 1) (Station n)
3/8 18
[1(P), 5(EA), 3(EB) port]

manual override)
(Slide locking
50PJG (20 pins) 50PH (10 pins)
(93.1)

78.3
84
For PC wiring Triangle mark Triangle mark
69.2

2B 2B

44.5
9.4
32.4
4A 4A
PE

PE
PCW type
5EA

5EA

(For DIN rail


10.8 (Pitch)

mounting)
10
46.6 P = 19

14.3
1P

1P

One-touch fitting
[4(A), 2(B) port]
3EB

3EB
X

Applicable tube O.D.: ø8, ø5/16"


: ø10,ø3/8"

Note) These figures show the “SS5Y7-50P2-05B-C10”.


Applicable connector: Applicable connector:
20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

Port size 02 One-touch fitting (Replaceable) 50RF12 - Stations UD

3
[Plug for external pilot]

2B 2B 2B
44.5

44.5
10.3
9.4
32.4

31.5

4A 4A 4A

10.8 55.7 (Pitch) P = 19


(Pitch) ∗ The above drawing shows when P,
46.6 P = 19 One-touch fitting E port entry is D.
(11)
[4(A), 2(B) port]
1/4 Applicable tube O.D.: ø6 ,ø1/4"
(22.9)
[4(A), 2(B) port] : ø8, ø5/16"
(For ø12) : ø10, ø3/8"
: ø12

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 123 148 160.5 185.5 198 223 235.5 260.5 273 298 310.5
L4 112.5 137.5 150 175 187.5 212.5 225 250 262.5 287.5 300
L5 15.5 18.5 15.5 18.5 15 18 15 18 14.5 17.5 14.5

41
Plug-in Metal Base Series SY3000/5000/7000

Valve
Plug-in Type 51/Bottom Ported

Dimensions: Series SY3000 Metal Base D-sub Connector

M5, 01
SS5Y3-51F 12- Stations D- CKC, N,   D side U side Manual override
KN
( )

Sub-plate
(Light/surge voltage suppressor) Push-turn locking slotted type:
Press, then rotate it.
(Pitch) 4(A) port side : Blue (For rubber seal)
2 x M2.6
45.1 P = 10.5 : Gray (For metal seal)
2 x 4-40 UNC
14 24.1 2(B) port side : Yellow
[For N or T thread]

Plug-in
(7.9)
4 x ø4.5
(For mounting)
B A B A B A B A B A

92.7
16

89
14 A 14 A 14 A 14 A 14 A

64.4

35
12 B 12 B 12 B 12 B 12 B

21.8
(Max. 3) L1

Metal Base
6.1 (Station 1) --- (Station n)

manual override)
(Slide locking
(68.7)

68.3
62.6
54.7
Panel fitting dimensions

Plug-in
32
(For 9 stations or more)

(4.1)
2 x ø4.5
(For 9 stations or more) (Pitch)
4

46.4 P = 10.5 One-touch fitting


40 23.6 [4(A), 2(B) port]

Manifold Exploded View


17.8

(For 9 stations or more) Applicable tube O.D.: ø2


4 x M4 x 0.7, thread depth 4

Type 50, 51, 52


4 x ø4.5 (For mounting) : ø3.2, ø1/8"

21.1
16.8

: ø4, ø5/32"
52.4
56.4
16

: ø6, ø1/4"
29.8

3EB 2B 2B
4 x M4 x 0.7

56.4
4 x ø4.5 4 4
1P

5EA 4A 4A

L3
16.8

Fitting dimensions for panel mounting


L2 1/8
C2, C3, C4 : 16
: 15

Refer to panel fitting dimensions for details.


[1(P), 5(EA), 3(EB) port]

Connector Connecting Base


2 x M4 x 0.7 L3
(For 9 stations or more) L2
C6

Note) These figures show the “SS5Y3-


Port size M5 Port size 01 One-touch fitting (Replaceable)
51F2-05D-C6”.
32

32

32

Plug-in
)C6: 12.8
N7: 16.6

(Pitch) (Pitch) (Pitch)


46.4 P = 10.5 46.4 P = 12.5 46.4 P = 10.5
21.1
20.1

20.1

Manifold Exploded View


(
29.8

29.8

29.8

3EB 2B 3EB 2B 3EB 2B

Type 10, 11, 12


17

17

1P 1P 1P

5EA 4A 5EA 4A 5EA 4A


14

M5 x 0.8 1/8 One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
Plug Assembly Part No.

: ø4, ø5/32"
One-touch Fittings/

: ø6, ø1/4"

Port Size M5, C, N, KC, KN


n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 — — — — — — — 68.5 73.8 79 84.3
Manifold Options

Port Size 01
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 — — — — — — — 77.8 84 90.3 96.5

42
Series SY3000/5000/7000

Plug-in Type 51/Bottom Ported

Dimensions: Series SY5000 Metal Base D-sub Connector

01, 02 D side U side


SS5Y5-51F 12- Stations D- CKC, N, 
KN
 (Light/surge voltage suppressor) Manual override

50
(Pitch)
P = 16
(
Push-turn locking slotted type:
Press, then rotate it. )
2 x M2.6 4(A) port side : Blue (For rubber seal)
16 24.1 : Gray (For metal seal)
2 x 4-40 UNC
2(B) port side : Yellow
[For N or T thread] (7.9)
4 x ø4.5
(For mounting)
B A B A B A B A B A

106.2
14 A 14 A 14 A 14 A 14 A

116.6
81.6

30.2 20
52.2
12 B 12 B 12 B 12 B 12 B

(Max. 3) L1

6.1 (Station 1) ------ (Station n)

manual override)
(Slide locking
(74.7)

74.3
68.6
60.7

38
Panel fitting dimensions

(4.9)
(Pitch)
2 x ø4.5 50 P = 16
2 x M4 x 0.7
25.2

(For 9 stations or more) 24 One-touch fitting


5

4 x M4 x 0.7, thread depth 5 (For 9 stations or more)


4 x ø4.5 [4(A), 2(B) port]
(For mounting)
Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
61.6
71.6

40.2

3EB 2B 2B
20

: ø8, ø5/16"
20 20

4 x M4 x 0.7

71.6
1P

4 x ø4.5
5EA 4A 4A
5 5
Fitting dimensions for panel mounting
L3 1/4
C4, C6 : 14.8
: 17.2

Refer to panel fitting dimensions for details.


L2 [1(P), 5(EA), 3(EB) port]
L3
L2
C8

Port size 01 Port size 02 One-touch fitting (Replaceable) Note) These figures show the “SS5Y5-
51F2-05D-C8”.
38

38

38
(15.5)

(Pitch) (Pitch) (Pitch)


50 P = 16 50 P = 17.5 50 P = 16
9.7
40.2

40.2

40.2

3EB 2B 3EB 2B 3EB 2B

1P 1P 1P
17.5
14.8

14.5

5EA 4A 5EA 4A 5EA 4A

1/8 1/4 One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"

Port Size 01, C, N, KC, KN


n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 — — — — — — — 93 101 109 117

Port Size 02
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 — — — — — — — 100.5 109.3 118 126.8

43
Plug-in Metal Base Series SY3000/5000/7000

Valve
Plug-in Type 51/Bottom Ported

Dimensions: Series SY7000 Metal Base D-sub Connector

02
SS5Y7-51(R)F 12 - Stations D- CKC, N, 
KN
(D) D side U side

Sub-plate
Manual override
(Light/surge voltage suppressor)
(
Push-turn locking slotted type:
Press, then rotate it. )
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent 52
(Pitch)
P = 19 4(A) port side: Blue (For rubber seal)

Plug-in
16 24.1 : Gray (For metal seal)
(23.9) 2(B) port side: Yellow

4 x ø4.5
B A B A B A B A B A

(For mounting) 14 A 14 A 14 A 14 A 14 A

116.7
133.2
92.1

84.6
32.1 24
62.6
(Connector entry upward direction)

Metal Base
12 B 12 B 12 B 12 B 12 B

2 x M2.6

NC
NC
2 x 4-40 UNC
[For N or T thread]

6.1 (Station 1) (Station n)

Plug-in
manual override)
(Slide locking
(81.2)

78.3
84
67.2

44.5

Manifold Exploded View


(5.4)

Type 50, 51, 52


(Pitch) 3/8
(Max. 3) 52 P = 19 [1(P), 5(EA), 3(EB) port]
M4 x 0.7 thread depth 5
4 x M4 x 0.7 thread depth 5
(For 9 stations or more)
(For mounting) 27
Fitting dimensions for
panel mounting

Connector Connecting Base


5

Refer to panel fitting

22 33.1
Port size 02 One-touch fitting (Replaceable) dimensions for details.
46.1

3EB 2B 2B
23 23
81.1

1P
(For ø12)

5EA 4A 4A
(29.5)

One-touch fitting
[4(A), 2(B) port]
L3 Applicable tube O.D. C8 : ø8
C10: ø10
5 L2

Plug-in
N9 : ø5/16"
L1 N11: ø3/8"
(17.6)

Note) These figures show the “SS5Y7-51F2-05D-C10”.

Manifold Exploded View


Type 10, 11, 12
One-touch fitting
[4(A), 2(B) port] Panel fitting dimensions
Applicable tube O.D.: ø6, ø1/4"
1/4" : ø8, ø5/16" 4 x ø4.5 2 x ø4.5
[4(A), 2(B) port] : ø10, ø3/8" (For 9 stations or more)
5

: ø12
24 27.1

Plug Assembly Part No.


32.8
22 33.1

One-touch Fittings/

3EB 2B 3EB 2B
81.1
72.1

1P 1P

4 x M4 x 0.7
22.6

5EA 4A 5EA 4A 5 5 4 x ø4.5


L3
L2
Manifold Options

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 — — — — — — — 107.5 117 126.5 136

44
Series SY3000/5000/7000

Plug-in Type 51/Bottom Ported

Dimensions: Series SY3000 Metal Base Flat Ribbon Cable

P M5, 01 D side U side


SS5Y3-51 PG 1
PH 2 - Stations D- C, N  Manual override
KC, KN
J
Applicable connector:
(Light/surge voltage suppressor)
(Pitch) (
Push-turn locking slotted type:
Press, then rotate it. )
45.1 P = 10.5 4(A) port side : Blue (For rubber seal)
26 pins MIL type with strain relief
(Conforming to MIL-C-83503) 14 24.1 : Gray (For metal seal)
2(B) port side : Yellow
(9.9)
51PJG (20 pins) 51PH (10 pins) 4 x ø4.5
(For mounting)
Triangle Triangle B A B A B A B A B A

92.7
16

89
For PC wiring mark mark
14 A 14 A 14 A 14 A 14 A

64.4

35
12 B 12 B 12 B 12 B 12 B

21.8
(Connector entry
PCW type

upward direction)
(Max. 3) L1
(Station 1) --- (Station n)
18

manual override)
Applicable connector: Applicable connector:

(Slide locking
20 pins MIL type with strain relief 10 pins MIL type with strain relief

(80.6)

68.3
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

62.6
56.7

32
Panel fitting dimensions

(4.1)
(For 9 stations or more)

(Pitch)
46.4 P = 10.5 One-touch fitting
2 x ø4.5 23.6 [4(A), 2(B) port]
4

(For 9 stations or more)


4 x M4 x 0.7, thread depth 4
40
(For mounting)
17.8

21.1
(For 9 stations or more)
16.8

4 x ø4.5
29.8

3EB 2B 2B
52.4
56.4
16

56.4
1P

4 x M4 x 0.7 5EA 4A 4A

4 x ø4.5
16.8

4 4 Fitting dimensions for panel mounting


1/8
C2, C3, C4 : 16
: 15

L3 Refer to panel fitting dimensions for details.


[1(P), 5(EA), 3(EB) port] L3
L2 2 x M4 x 0.7
(For 9 stations or more) L2
C6

Port size M5 Port size 01 One-touch fitting (Replaceable) Note) These figures show the “SS5Y3-
51P2-05D-C6”.
32

32

32

(Pitch) (Pitch) (Pitch)


20.1

21.1

20.1

46.4 P = 10.5 46.4 P = 12.5 46.4 P = 10.5


)C6: 12.8
N7: 16.6
29.8

29.8

29.8

3EB 2B 3EB 2B 3EB 2B


17

17
(

1P 1P 1P

5EA 4A 5EA 4A 5EA 4A


14

One-touch fitting
M5 x 0.8 1/8
[4(A), 2(B) port]
[4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
: ø6, ø1/4"
Port Size M5, C, N, KC, KN
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 — — — — — — — 68.5 73.8 79 84.3
Port Size 01
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 — — — — — — — 77.8 84 90.3 96.5
45
Plug-in Metal Base Series SY3000/5000/7000

Valve
Plug-in Type 51/Bottom Ported

Dimensions: Series SY5000 Metal Base Flat Ribbon Cable

P 01, 02 D side U side


SS5Y5-51 PG 1
PH 2 - Stations D- C, N  Manual override

Sub-plate
KC, KN
J Applicable connector:
26 pins MIL type with strain relief
(Light/surge voltage suppressor)
(Pitch)
(
Push-turn locking slotted type:
Press, then rotate it. )
(Conforming to MIL-C-83503) 4(A) port side : Blue (For rubber seal)
50 P = 16
: Gray (For metal seal)
Triangle mark 16 24.1 2(B) port side : Yellow

Plug-in
(9.9) 4 x ø4.5
(For mounting)
B A B A B A B A B A

106.2
14 A 14 A 14 A 14 A 14 A

116.6
51PJG (20 pins) 51PH (10 pins)

81.6

30.2 20
52.2
For PC wiring Triangle mark Triangle mark 12 B 12 B 12 B 12 B 12 B

(Max. 3) L1

Metal Base
(Connector entry
PCW type

upward direction) (Station 1) ------ (Station n)


18

manual override)
(Slide locking
(86.6)

74.3

Plug-in
68.6
62.7
Applicable connector: Applicable connector:

38
20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)
(Pitch)

(4.9)
50 P = 16

Manifold Exploded View


Panel fitting dimensions 2 x M4 x 0.7

Type 50, 51, 52


(For 9 stations or more)
24 One-touch fitting
2 x ø4.5 4 x M4 x 0.7, thread depth 5 [4(A), 2(B) port]
25.2

(For 9 stations or more) (For mounting) Applicable tube O.D.: ø4, ø5/32"
5

4 x ø4.5 : ø6, ø1/4"


40.2

3EB 2B 2B
: ø8, ø5/16"
20 20

71.6
61.6
71.6
20

1P

4 x M4 x 0.7 5EA 4A 4A

4 x ø4.5 Fitting dimensions for panel mounting


5 5 1/4

Connector Connecting Base


L3 Refer to panel fitting dimensions for details.

C4, C6 : 14.8
: 17.2
[1(P), 5(EA), 3(EB) port]
L2 L3
L2
C8
Port size 01 Port size 02 One-touch fitting (Replaceable)
Note) These figures show the “SS5Y5-
51P2-05D-C8”.

Plug-in
38

38

38

(Pitch) (Pitch) (Pitch)


50 P = 16 50 P = 17.5 50 P = 16
(15.5)

Manifold Exploded View


9.7

Type 10, 11, 12


40.2

40.2

40.2

3EB 2B 3EB 2B 3EB 2B

1P 1P 1P
17.5

14.5
14.8

5EA 4A 5EA 4A
5EA 4A

1/8 1/4 One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
Plug Assembly Part No.
One-touch Fittings/

: ø6, ø1/4"
: ø8, ø5/16"

Port Size 01, C, N, KC, KN


n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
Manifold Options

L3 — — — — — — — 93 101 109 117


Port Size 02
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 — — — — — — — 100.5 109.3 118 126.8

46
Series SY3000/5000/7000
Plug-in Type 51/Bottom Ported

Dimensions: Series SY7000 Metal Base Flat Ribbon Cable

P 02
SS5Y7-51(R) PG 1
PH 2 - Stations D- C, N (D) D side U side
J KC, KN
Manual override
(Light/surge voltage suppressor)
(Pitch)
(Push-turn locking slotted type:
Press, then rotate it. )
52 P = 19 4(A) port side: Blue (For rubber seal)
Applicable connector: : Gray (For metal seal)
16 24.1
Triangle mark 26 pins MIL type with strain relief 2(B) port side: Yellow
(25.9)
(Conforming to MIL-C-83503)

4 x ø4.5
B A B A B A B A B A

(For mounting) 14 A 14 A 14 A 14 A 14 A

116.7
133.2
92.1

84.6
32.1 24
62.6
(Connector entry upward direction)
12 B 12 B 12 B 12 B 12 B

NC
NC
18 (Station 1) (Station n)
50PJG (20 pins) 51PH (10 pins)
Triangle mark

manual override)
Triangle mark

(Slide locking
For PC wiring
(93.1)

78.3
84
69.2

44.5
PCW type

(5.4)
4 x M4 x 0.7 thread depth 5
(For mounting) 3/8
(Pitch)
(Max. 3) 52 P = 19 [1(P), 5(EA), 3(EB) port]

Applicable connector: Applicable connector: M4 x 0.7 thread depth 5


20 pins MIL type with strain relief 10 pins MIL type with strain relief 27 (For 9 stations or more)
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) Fitting dimensions for
panel mounting
5

Refer to panel fitting


dimensions for details.
22 33.1
Port size 02 One-touch fitting (Replaceable)
46.1

3EB 2B 2B
23 23
81.1

1P

5EA 4A 4A
(For ø12)
(29.5)

One-touch fitting
[4(A), 2(B) port]
L3 Applicable tube O.D. C8 : ø8
C10: ø10
5 L2 N9 : ø5/16"
L1 N11: ø3/8"
(17.6)

One-touch fitting Note) These figures show the “SS5Y7-51P2-05D-C10”.


[4(A), 2(B) port]
Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16" Panel fitting dimensions
: ø10, ø3/8"
: ø12
4 x ø4.5 2 x ø4.5
1/4
(For 9 stations or more)
[4(A), 2(B) port]
5

24 27.1
32.8
22 33.1

3EB 2B 3EB 2B
81.1
72.1

1P 1P

4 x M4 x 0.7
22.6

5EA 4A 5EA 4A
5 5 4 x ø4.5
L3
L2

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 — — — — — — — 107.5 117 126.5 136

47
48
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Plug-in Metal Base
Type 52
D-sub Connector Flat Ribbon Cable PC Wiring
Top Ported

Series SY3000/5000/7000
RoHS
How to Order Manifold

SS5Y 3 52 F 1 05 D
        
 Series  Type  Connector type
3 SY3000 52 Top ported F: D-sub connector P: Flat ribbon cable PG: Flat ribbon cable
5 SY5000 52R Top ported, External pilot (25 pins) (26 pins) (20 pins)
7 SY7000

 Connector entry direction


1: Upward 2: Lateral

PH: Flat ribbon cable J: PC wiring


(10 pins) (20 pins)

 Wiring type
Nil All double wiring Note 1)
S All single wiring Note 2)  Valve stations
Note 1) All double wiring: 2-position single, double, 3-position and 4-position
valves can be used on all manifold stations. F: D-sub connector (25 pins) P: Flat ribbon cable (26 pins) PG: Flat ribbon cable (20 pins)
Note 2) All single wiring: Available only for the manifold which has 2-position Symbol Stations Note Symbol Stations Note Symbol Stations Note
single for all stations. 02 2 stations All 02 2 stations All 02 2 stations All
Note that 2-position double, 3- or 4-position valves cannot be used.
Note 3) If a mix of single and double wiring is required, it is supplied as a double double double
special order. 12 12 stations wiring 12 12 stations wiring 09 9 stations wiring
02 2 stations All 02 2 stations All 02 2 stations All
How to Order Manifold Assembly single single single
12 12 stations wiring 12 12 stations wiring 12 12 stations wiring

Example (SS5Y3-52F2-) PH: Flat ribbon cable (10 pins) J: PC wiring (20 pins)
2-position double (24 VDC) Symbol Stations Note Symbol Stations Note
2-position single (24 VDC)
SY3130-5U1-C6 (3 sets) SY3230-5U1-C6 (1 set) 02 2 stations All 02 2 stations All
3-position closed double double
center (24 VDC) 04 4 stations wiring 08 8 stations wiring
SY3330-5U1-C6 (1 set) 02 2 stations 02 2 stations
All All
single single
08 8 stations wiring 12 12 stations wiring
∗ This also includes the number of blanking plate assembly.

Us
ide  P, E port entry  Thread type
on
s U U side Note) Nil Rc
ati
St D D side Note) 00F G
Manifold base 3 B Both sides 00N NPT
2
(5 stations) 1 00T NPTF
e Note) Plugs are mounted on the opposite
SS5Y3-52F2-05D sid
D side of the selected ports.

SS5Y3-52F2-05D ·········1 set (Type 52 5-station manifold base part no.)  Mounting
∗SY3130-5U1-C6 ···········3 sets (2-position single part no.)
∗SY3230-5U1-C6 ···········1 set (2-position double part no.) Nil Direct mounting
∗SY3330-5U1-C6 ···········1 set (3-position closed center part no.) D DIN rail mounting (With DIN rail)
The asterisk denotes the symbol for assembly.
D0 DIN rail mounting (Without DIN rail)
Prefix it to the part numbers of the valve etc. D3 For 3 stations
Specify a longer rail than
• The valve arrangement is numbered as the 1st station from the D side. the standard length.
D12 For 12 stations
• Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement Note) Refer to page 247 for the fixation of DIN rail
becomes complicated, specify on a manifold specification sheet. mounting type manifold.

49
Plug-in Metal Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
            

Plug-in
Top ported

 Series  Coil type  A, B port size


3 SY3000 Nil Standard Thread piping
5 SY5000 With power saving circuit Symbol Port size Applicable series
T
7 SY7000 (Continuous duty type) M5 M5 x 0.8 SY3000
∗ Be sure to select the power saving circuit type 01 1/8 SY5000

Metal Base
when a valve is continuously energized for long 02 1/4 SY7000
 Type of actuation periods of time.
1 Single ∗ Be careful of the energizing time when the One-touch fitting (Metric)
2-position power saving circuit is selected. Refer to page Symbol A, B port SY3000 SY5000 SY7000
2 Double
3 Closed center 244 for details. C2 ø2  — —

Plug-in
4 3-position Exhaust center C3 ø3.2  — —
5 Pressure center  Rated voltage C4 ø4   —
A∗ 4-position N.C./N.C. 5 24 VDC
C6 ø6   
B∗ dual N.O./N.O. 6 12 VDC
C8 ø8 —  
C∗ 3-port N.C./N.O. C10 ø10 — — 
C12 ø12 — —

Manifold Exploded View



∗ Only rubber seal type is available for the
 Light/surge voltage suppressor

Type 50, 51, 52


4-position dual 3-port valve. One-touch fitting (Inch)
and common specification Symbol A, B port SY3000 SY5000 SY7000
 Seal type Symbol With light
Surge voltage Common N1 ø1/8"  — —
suppressor specification N3 ø5/32"   —
0 Rubber seal
Nil — — N7 ø1/4"   
1 Metal seal
R — Non-polar N9 ø5/16" —  
U  N11 ø3/8" — — 
 Pilot type S — Positive

Connector Connecting Base


 common
Nil Z 
Internal pilot
NS — Negative
 Thread type
R External pilot
NZ  common Nil Rc
∗ Only “Z” and “NZ” types are available for with the F G
 Back pressure check valve power saving circuit. N NPT
(Built-in valve type) T NPTF
Nil None  Manual override ∗ Only Nil is available for M5.
H Built-in
Nil: D:
 Type of mounting screw

Plug-in
∗ Only rubber seal type
Non-locking Push-turn
∗ Back pressure check valve is not available for the
3-position type and the SY7000. push type locking Nil Round head combination screw
slotted B Hexagon socket head cap screw

Manifold Exploded View


type Round head combination screw
K

Type 10, 11, 12


(Falling-out-prevention type)
 Pilot valve option H Hexagon socket head cap screw
Nil Standard (102 psi (0.7 MPa)) (Falling-out-prevention type)
B Quick response type (102 psi (0.7 MPa)) E: F: ∗ For “K” and “H”, the valve body cover has a drop
Push-turn Slide locking
K∗ High pressure type (145 psi (1.0 MPa)) prevention construction to stop the mounting
locking lever type screws from falling out when the valve is
∗ Only metal seal type is available for the high type removed for maintenance etc.
pressure type. ∗ When ordering a valve individually, the base
gasket is not included. Since the base gasket is
Plug Assembly Part No.

attached to the manifold, please order the base


One-touch Fittings/

gasket separately if it is needed for maintenance


service.
∗ Refer to page 14 for with the safety slide locking
Refer to page 73 for part numbers of the base
manual override.
gasket and mounting screw.
∗ "B" and "H" cannot be selected for the individual
SUP/EXH spacer assembly or interface
regulator.
Manifold Options

Protective class
class III (Mark: )

50
Series SY3000/5000/7000

Plug-in Type 52/Top Ported

Dimensions: Series SY3000 Metal Base D-sub Connector, Flat Ribbon Cable

F
P 1 U D side U side
SS5Y3-52(R) PG - Stations D -(D) L3
PH 2 B
J 5.3 L4
(DIN rail mounting hole pitch: 12.5)
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent (Pitch) Manual override

68.3
DIN rail holding screw
(For DIN rail mounting)
14
45.1
24.1
P = 10.5
(Push-turn locking slotted type:
Press, then rotate it. )
(Light/surge 4(A) port side : Blue (For rubber seal)
(Slide locking manual override) (7.9) voltage : Gray (For metal seal)
M5 x 0.8 (External pilot) DIN rail bracket mounting screw suppressor) 2(B) port side : Yellow
[Pilot EXH port] (For DIN rail mounting)

DIN rail

5.5
(Connector entry B A B A B A B A B A

upward direction)

92.7
4A 4A 4A 4A 4A
5EA

89
PE
16.8 17.2
79

15.9 16.2
64.4

56.9
16
1P

2 x M2.6

11
32.1
35
29.8

35
X

26.6
2 x 4-40 UNC

21.8
2B 2B 2B 2B 2B
3EB

[For N or T thread]
8.6 4 x ø4.5
8 One-touch fitting
14.5 (For mounting) 4 L2
M5 x 0.8 (External pilot) [4(A), 2(B) port]
22.1 (L5) L1 Applicable tube O.D.: ø2
[External pilot port]
28 : ø3.2, ø1/8"
1/8 M5 x 0.8
: ø4, ø5/32"
[1(P), 5(EA), 3(EB) port] [4(A), 2(B) port] : ø6, ø1/4"
(Station 1) --- (Station n)
6.1
F
52R PJ 12 - Stations U
D

)C6: 76.8
N7: 80.6
(68.7)
62.6
54.7

(
[Plug for external pilot]

32

(For DIN rail


7.5

mounting)
11.8
∗ The above drawing shows when P, E
port entry is D.

Note) These figures show the “SS5Y3-52F2-05B”.

52P (26 pins) 52PJG (20 pins) 52PH (10 pins)


For PC wiring
Triangle mark Triangle mark Triangle mark
14 (9.9) 14 (9.9) 14 (9.9)

B A B A B A
4A 4A 4A
5EA

5EA

5EA
PE

PE

PE
PCW type
1P

1P

1P
X

2B 2B 2B
3EB

3EB

3EB

Applicable connector: Applicable connector: Applicable connector:


26 pins MIL type with strain relief 20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17

51
Plug-in Metal Base Series SY3000/5000/7000

Valve
Plug-in Type 52/Top Ported

Dimensions: Series SY5000 Metal Base D-sub Connector, Flat Ribbon Cable

F
P U
SS5Y5-52(R) PG D -(D)
1 Stations
- D side U side

Sub-plate
PH 2 B
L3 Manual override
J L4
( ) ( )
JIS-X-5101 5.3 Push-turn locking slotted type:
Applicable connector: D-sub MIL-C-24308 equivalent (DIN rail mounting hole pitch: 12.5) Press, then rotate it.
(Pitch) 4(A) port side : Blue (For rubber seal)
74.3
P = 16 (Light/surge

Plug-in
DIN rail holding screw 50 : Gray (For metal seal)
(Slide locking manual override) voltage
68.6 (For DIN rail mounting) 16 24.1 2(B) port side : Yellow
M5 x 0.8 (External pilot) suppressor)
DIN rail bracket mounting screw (7.9)
[Pilot EXH port]

01 : 16.2
C : 14.5
(For DIN rail mounting)
DIN rail

(Connector entry B A B A B A B A B A
4A 4A 4A 4A 4A
PE

upward direction)
5EA

106.2
5.5
23.2

116.6
96.2

35
20
81.6

Metal Base
20

74.1
1P
24.6
20

52.2

43.8
2 x M2.6

40.2
40.2

8
3EB

30.2
X

2B 2B 2B 2B 2B
2 x 4-40 UNC
[For N or T thread]
12.3

Plug-in
1/8
M5 x 0.8 (External pilot) 4 x ø4.5 One-touch fitting
18 [4(A), 2(B) port]
[External pilot port] (For mounting) [4(A), 2(B) port]
28 5 L2
1/4 Applicable tube O.D.: ø4, ø5/32"
34 (L5) L1 : ø6, ø1/4"
[1(P), 5(EA), 3(EB) port]
: ø8, ø5/16"

52P (26 pins) (Station 1) ----------- (Station n)

Manifold Exploded View


Type 50, 51, 52
6.1
Triangle mark 16 (9.9)

(86.7)
(74.7)
72.3
60.7

B A
4A
PE
5EA

38

Connector Connecting Base


1P
3EB
X

(For DIN rail


10
2B

mounting)
14.3
Applicable connector: Note) These figures show the “SS5Y5-52F2-05B”.
26 pins MIL type with strain relief
(Conforming to MIL-C-83503)

Plug-in
F
52PJG (20 pins) 52PH (10 pins) 52R PJ 12 - Stations UD
For PC wiring
16 (9.9) Triangle mark 16 (9.9)
Triangle mark

Manifold Exploded View


Type 10, 11, 12
3
[Plug for external pilot]
B A B A
4A 4A
PE

PE
5EA

5EA
PCW type
1P

1P
3EB

3EB
X

2B 2B
∗ The above drawing shows when P, E
Plug Assembly Part No.

port entry is D.
One-touch Fittings/

Applicable connector: Applicable connector:


20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

n: Stations 2 3 4 5 6 7 8 9 10 11 12
Manifold Options

L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5

52
Series SY3000/5000/7000

Plug-in Type 52/Top Ported

Dimensions: Series SY7000 Metal Base D-sub Connector, Flat Ribbon Cable
F
1 P U
SS5Y7-52(R) PG
PH 2
- Stations D -(D) D side
L3 U side
B L4
J JIS-X-5101 5.3
(
Applicable connector: D-sub MIL-C-24308 equivalent ) (DIN rail mounting hole pitch: 12.5)
Manual override

84
DIN rail holding screw 52
P = 19
(Pitch)
(
Push-turn locking slotted type:
Press, then rotate it. )
(Slide locking manual override) 16 24.1 4(A) port side : Blue (For rubber seal)
(For DIN rail mounting) (Light/surge voltage
M5 x 0.8 (External pilot) 78.3 suppressor) : Gray (For metal seal)
(7.9) 2(B) port side : Yellow
PE: Pilot EXH port
DIN rail bracket mounting screw
(For DIN rail mounting)

(DIN rail) B A B A B A B A B A

5.5
4A 4A 4A 4A 4A
PE
5EA

116.7
23.8
28

35
102.1

133.2
92.1

84.6
24
1P
23.8

62.6
28.2

49.7
45.6
44.1

22.6
8
3EB
X

2 x M2.6

32.1
2B 2B 2B 2B 2B
2 x 4-40 UNC

NC
NC
[For N or T thread]
18.1 4 x ø4.5 1/4
20.9 (For mounting) [1 (A), 2 (B) port]
One-touch fitting
34.5 M5 x 0.8 (External pilot) 5 L2
[4(A), 2(B) port]
40.5 X: External pilot port (L5) L1 Applicable tube O.D. : ø6, ø1/4"
3/8
(Connector entry upward direction) : ø8, ø5/16"
[1 (P), 5 (EA), 3 (EB) port] : ø10, ø3/8"
(Station 1) (Station n) : ø12
52P (26 pins)
Triangle mark 16 (9.9) 6.1

(A, B port: ø12)


(110.3)
(98.4)
B A
(81.2)
87

4A
PE
5EA

67.2

44.5
1P
3EB
X

2B

(For DIN rail


10

mounting)
14.3
Applicable connector:
26 pins MIL type with strain relief Note) These figures show the “SS5Y7-52F2-05B”.
(Conforming to MIL-C-83503)
F
52PJG (20 pins) 52PH (10 pins) 52R PJ 12 - Stations UD
For PC wiring Triangle mark 16 (9.9) Triangle mark 16 (9.9)

3
[Plug for external pilot]
B A B A
4A 4A
PE

PE
PCW type
5EA

5EA
1P

1P
3EB

3EB
X

2B 2B

∗ The above drawing shows when P,


E port entry is D.
Applicable connector: Applicable connector:
20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 123 148 160.5 185.5 198 223 235.5 260.5 273 298 310.5
L4 112.5 137.5 150 175 187.5 212.5 225 250 262.5 287.5 300
L5 15.5 18.5 15.5 18.5 15 18 15 18 14.5 17.5 14.5

53
Plug-in Metal Base Series SY3000/5000/7000

Valve
Electrical Wiring Specifications Cable Assembly
015
D-sub connector
AXT100-DS25- 030 (N) [IP40 compliant]

Sub-plate
050 Lead wire color for
Nil: Metric size
N: Inch size D-sub connector
1
cable assembly by
14 2 terminal number
15 Cable

Plug-in
3 Lead Dot
16 4 0.3 mm2 x 25 cores Terminal wire
17 no. marking
5 O.D. ø1.4 color
18 6 1 Black None
19 Approx. ø10
7 2 Brown None
20 8
21 9 3 Red None
22 Connector terminal no. Seal (Length)
10 015 4 Orange None
23 11
24 5 Yellow None
12

L
25 13 Molded cover 6 Pink None

Metal Base
7 Blue None
2 x M2.6 x 0.45

44
or 2 x 4-40 UNC 8 Purple White
Connector JBZ-25S-3 9 Gray Black
<All single wiring> <All double wiring> made by J.S.T. Mfg. 10 White Black

8
Terminal no. Terminal no. Polarity Co., Ltd.
11 White Red

Plug-in
(2.4)
SOL.a SOL.a 55 12 Yellow Red
Station 1 1 1 (–) (+) Socket side
SOL.a Station 1 SOL.b 13 Orange Red
Station 2 14 14 (–) (+) 14 25
SOL.a SOL.a 14 Yellow Black
Station 3 2 2 (–) (+) Terminal no.
Station 2

16
SOL.a SOL.b 15 Pink Black
Station 4 15 15 (–) (+)
SOL.a SOL.a 16 Blue White
Station 5 3 3 (–) (+) 1 13

Manifold Exploded View


SOL.a Station 3 SOL.b 47.04 17 Purple None
Station 6 16 16 (–) (+)

Type 50, 51, 52


SOL.a 4 SOL.a 18 Gray None
Station 7 4 (–) (+)
SOL.a Station 4 SOL.b 19 Orange Black
Station 8 17 17 (–) (+)
SOL.a 5 SOL.a 20 Red White
Station 9 5 (–) (+)
SOL.a Station 5 SOL.b 21 Brown White
Station 10 18 18 (–) (+)
SOL.a SOL.a D-sub connector cable assembly 22 Pink Red
Station 11 6 6 (–) (+)
SOL.a Station 6 SOL.b Cable 23 Gray Red
Station 12 19 19 (–) (+) Assembly part no. Note
SOL.a length (L) 24 Black White
7 7 (–) (+)
Station 7 SOL.b 1.5 m AXT100-DS25-015 25 White None

Connector Connecting Base


20 20 (–) (+) Cable
8 SOL.a 3m AXT100-DS25-030 0.3 mm2 x 25 cores
8 (–) (+)
Station 8 SOL.b 5m AXT100-DS25-050
21 21 (–) (+)
SOL.a ∗ When using a standard commercial
9 9 (–) (+)
Station 9 SOL.b connector, use a 25-pin type female
22 22 (–) (+) connector conforming to MIL-C-24308.
SOL.a
10 10 (–) (+) ∗ Cannot be used for movable wiring.
Station 10 SOL.b
23 23 (–) (+) ∗ Lengths other than the above are also
11 SOL.a available. Please contact SMC for details.
11 (–) (+)
Station 11 SOL.b
24 24 (–) (+)
Electrical characteristics Connector Manufacturers’ Example

Plug-in
12 SOL.a
12 (–) (+)
Station 12 SOL.b Item Property
25 25 (–) (+) • Fujitsu, Ltd.
Conductor resistance • Japan Aviation Electronics Industry, Ltd.
Ω/km, 20°C 65 or less
• J.S.T. Mfg. Co., Ltd.

Manifold Exploded View


COM. COM.
13 13 (+) (–) • Hirose Electric Co., Ltd.

Type 10, 11, 12


Voltage limit
Positive Negative V, 1 minute, AC 1000
common common
Insulation resistance
MΩ/km, 20°C 5 or more
Note) When using a valve with no polarity, either positive common or negative
common can be used. Note) The minimum bending radius
of the D-sub connector cable
is 20 mm.
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

54
Series SY3000/5000/7000
Electrical Wiring Specifications Cable Assembly
10 1
Flat ribbon cable connector AXT100-FC 20 - 2
26 3
26 25
24 23
6 Terminal no. 28AWG
Red
22 21
20 19

17.2 (10 pins)

37.5 (26 pins)


30 (20 pins)

1
18 17
16 15
14 13
12 11 Connector terminal no.
10 9

26

25
8 7
Triangle mark indicator position (15.6)
6 5
4 3 L
2 1
Flat ribbon cable connector assembly
Cable Assembly part no.
P: Flat ribbon cable (26 pins) length (L) 26 pins 20 pins 10 pins
<All single wiring> <All double wiring> 1.5 m AXT100-FC26-1 AXT100-FC20-1 AXT100-FC10-1
Terminal no. Terminal no. Polarity 3m AXT100-FC26-2 AXT100-FC20-2 AXT100-FC10-2
SOL.a 1 SOL.a (–) (+) AXT100-FC26-3 AXT100-FC20-3 AXT100-FC10-3
Station 1 1 5m
Station 2
SOL.a 2 Station 1 SOL.b 2 (–) (+) ∗ When using a standard commercial connector, use a 26-pin, 20-pin or 10-pin
SOL.a 3 SOL.a 3 (–) (+)
Station 3 type connector conforming to MIL-C-83503 with strain relief.
Station 4
SOL.a 4 Station 2 SOL.b 4 (–) (+) ∗ Cannot be used for movable wiring.
Station 5 SOL.a 5 SOL.a 5 (–) (+) ∗ Lengths other than the above are also available. Please contact SMC for
Station 6
SOL.a 6 Station 3 SOL.b 6 (–) (+) details.
Station 7 SOL.a 7 SOL.a 7 (–) (+)
Station 8 SOL.a 8 Station 4 SOL.b 8 (–) (+) Connector Manufacturers’ Example
Station 9 SOL.a 9 SOL.a 9 (–) (+)
Station 10 SOL.a 10 Station 5 SOL.b 10 (–) (+) • Hirose Electric Co., Ltd. • Japan Aviation Electronics Industry, Ltd.
Station 11 SOL.a 11 SOL.a 11 (–) (+) • Sumitomo 3M Limited • J.S.T. Mfg. Co., Ltd.
Station 12 SOL.a 12 Station 6 SOL.b 12 (–) (+) • Fujitsu, Ltd. • Oki Electric Cable Co., Ltd.
13 SOL.a 13 (–) (+)
Station 7 SOL.b 14
14 (–) (+)
15 SOL.a 15 (–) (+) PH: Flat ribbon cable (10 pins)
Station 8 SOL.b 16
16 (–) (+) <All single wiring> <All double wiring>
17 SOL.a 17 (–) (+)
Station 9 SOL.b 18 Terminal no. Terminal no. Polarity
18 (–) (+) SOL.a SOL.a
19 SOL.a 19 (–) (+) Station 1 1 1 (–) (+)
Station 10 SOL.a Station 1 SOL.b
SOL.b 20 (–) (+) Station 2 2 2 (–) (+)
20 SOL.a SOL.a
SOL.a 21 (–) (+) Station 3 3 3 (–) (+)
21 SOL.a Station 2 SOL.b
Station 11 SOL.b 22 Station 4 4 4 (–) (+)
22 (–) (+) SOL.a SOL.a
23 SOL.a 23 (–) (+) Station 5 5 5 (–) (+)
Station 12 SOL.a Station 3 SOL.b
24 SOL.b 24 (–) (+) Station 6 6 6 (–) (+)
Station 7 SOL.a SOL.a 7 (–) (+)
COM. COM. 7
25 25 (+) (–) SOL.a Station 4 SOL.b
COM. 26 COM. Station 8 8 8 (–) (+)
26 (+) (–) COM. COM.
9 9 (+) (–)
Positive Negative COM. 10 COM.
10 (+) (–)
common common
Positive Negative
common common
PG: Flat ribbon cable (20 pins)
<All single wiring> <All double wiring> J: Flat ribbon cable (20 pins) PC wiring
Terminal no. Terminal no. Polarity
SOL.a SOL.a <All single wiring> <All double wiring>
Station 1 1 1 (–) (+)
SOL.a Station 1 SOL.b Terminal no. Terminal no. Polarity
Station 2 2 2 (–) (+)
SOL.a SOL.a (–) (+) SOL.a 20 SOL.a 20 (–) (+)
Station 3 3 3 Station 1
SOL.a Station 2 SOL.b SOL.a Station 1 SOL.b 18
Station 4 4 4 (–) (+) Station 2 18 (–) (+)
Station 5 SOL.a SOL.a 5 (–) (+) SOL.a SOL.a 16 (–) (+)
5 Station 3 16
SOL.a Station 3 SOL.b SOL.a Station 2 SOL.b 14
Station 6 6 6 (–) (+) Station 4 14 (–) (+)
Station 7 SOL.a SOL.a 7 (–) (+) Station 5 SOL.a SOL.a 12
7 12 (–) (+)
SOL.a Station 4 SOL.b SOL.a Station 3 SOL.b 10
Station 8 8 8 (–) (+) Station 6 10 (–) (+)
Station 9 SOL.a SOL.a 9 (–) (+) Station 7 SOL.a SOL.a
9 8 8 (–) (+)
SOL.a Station 5 SOL.b 10 SOL.a Station 4 SOL.b
Station 10 10 (–) (+) Station 8 6 6 (–) (+)
Station 11 SOL.a SOL.a 11 (–) (+) Station 9 SOL.a SOL.a
11 19 19 (–) (+)
SOL.a Station 6 SOL.b 12 SOL.a 17 Station 5 SOL.b
Station 12 12 (–) (+) Station 10 17 (–) (+)
SOL.a 13 (–) (+) Station 11 SOL.a 15 SOL.a
13 15 (–) (+)
Station 7 SOL.b 14 SOL.a 13 Station 6 SOL.b
14 (–) (+) Station 12 13 (–) (+)
SOL.a 15 (–) (+) 11 SOL.a
15 11 (–) (+)
Station 8 SOL.b 16 Station 7 SOL.b
16 (–) (+) 9 9 (–) (+)
SOL.a 17 (–) (+) 7 SOL.a
17 7 (–) (+)
Station 9 SOL.b 18 Station 8 SOL.b
18 (–) (+) 5 5 (–) (+)
COM. 19 COM. 4 4
19 (+) (–)
COM. 20 COM. 3 3
20 (+) (–)
COM. 2 COM. 2 (+) (–)
Positive Negative
common common COM. 1 COM. 1 (+) (–)
Positive Negative
Note) When using a valve with no polarity, either positive common or negative
common common
common can be used.

55
56
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Type 50
Side Ported Plug-in Metal Base EX510

Series SY3000/5000/7000
Type 51
Bottom Ported

How to Order Manifold

SS5Y 3 50 S5 05 D C6
        
 Series  Type  Valve stations
3 SY3000 50 Side ported Symbol Stations Note Symbol Stations Note
5 SY5000 51 Bottom ported 02 2 stations 02 2 stations
All double All single
7 SY7000 50R Side ported, External pilot
wiring wiring
∗ External pilot is not available for 08 8 stations 12 12 stations
 SI unit output polarity the bottom ported type. ∗ This also includes the number of blanking plate assembly.
Nil Positive common
N Negative common
 P, E port entry
U U side Note 1) Note 1) Plugs are mounted on the opposite
side of the selected ports.
 Wiring type D D side Note 1) Note 2)
Note 2) Only D side is available for Type 51
B Both sides (Bottom ported).
Nil All double wiring Note 1)
S All single wiring Note 2)  A, B port size
Note 1) All double wiring: 2-position single, double, 3-position and 4-position Thread piping
valves can be used on all manifold stations.
Note 2) All single wiring: Available only for the manifold which has 2-position
Symbol A, B port SY3000 SY5000 SY7000
single for all stations. M5 M5 x 0.8  — —
Note that 2-position double, 3- or 4-position valves cannot be used. 01 1/8   —
Note 3) If a mix of single and double wiring is required, it is supplied as a 02 1/4 —  
special order. One-touch fitting (Metric)
Symbol A, B port SY3000 SY5000 SY7000
C2 ø2  — —
C3 ø3.2  — —
How to Order Manifold Assembly C4 ø4   —
Fixed

C6 ø6   —
Example (SS5Y3-50S5-) C8 ø8 —  
2-position double (24 VDC)
2-position single (24 VDC) C10 ø10 — — 
SY3100-5U1 (3 sets) SY3200-5U1 (1 set)
3-position closed KC2 ø2  — — Type 50 Type 51
center (24 VDC) (Side ported) (Bottom ported)
KC3 ø3.2  — —
SY3300-5U1 (1 set)
KC4 ø4   —
Replaceable

KC6 ø6   
KC8 ø8 —  
KC10 ø10 — — 
KC12 ø12 — — 
ide M∗ Mixed sizes   
Us
P, E port size (Thread piping) 1/8 1/4 3/8
s
n
tio
ta

One-touch fitting (Inch)


S

3
Manifold base 2 Symbol A, B port SY3000 SY5000 SY7000
1
(5 stations) ide N1 ø1/8" — —
SS5Y3-50S5-05D-C6 Ds 
N3 ø5/32"   —
Fixed

SS5Y3-50S5-05D-C6 ···1 set (Type 50 5-station manifold base part no.)


N7 ø1/4"   —
∗SY3100-5U1 ·················3 sets (2-position single part no.)
∗SY3200-5U1 ·················1 set (2-position double part no.) N9 ø5/16" —  
∗SY3300-5U1 ·················1 set (3-position closed center part no.) N11 ø3/8" — — 
The asterisk denotes the symbol for assembly. KN1 ø1/8"  — — Type 50 Type 51
Prefix it to the part numbers of the valve etc. (Side ported) (Bottom ported)
KN3 ø5/32"   —
Replaceable

• The valve arrangement is numbered as the 1st station from the D side.
KN7 ø1/4"   
• Under the manifold part number, state the valves to be mounted in order from
the 1st station as shown in the figure above. If the arrangement becomes KN9 ø5/16" —  
complicated, specify on a manifold specification sheet. KN11 ø3/8" — — 
Note) When mixing top ported configurations, select from page 68. M∗ Mixed sizes   
In this case, use caution as there is also output on the A and B port on base side.
P, E port size (Thread piping) 1/8 1/4 3/8
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side. ∗ When ports are mixed sizes, indicate the piping specifications on the manifold specification sheet.

57
Plug-in Metal Base Series SY3000/5000/7000

Valve
 Thread type  Mounting

Sub-plate
Nil Rc Nil Direct mounting
F G DIN rail mounting
D
N NPT (With DIN rail) For details about the EX510 Gateway-type
T NPTF

Plug-in
DIN rail mounting Serial Transmission System, refer to the
D0 (Without DIN rail) WEB catalog or the Best Pneumatics No. 1
D3 For 3 stations and the Operation Manual. Please download
Specify a longer rail than the Operation Manual via SMC website,
the standard length. http://www.smcworld.com
D12 For 12 stations
Note 1) Only direct mounting is available for Type
51 (Bottom ported).
Note 2) Refer to page 247 for the fixation of DIN
rail mounting type manifold.

Metal Base
How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 0 0 5 1

Plug-in
 Manual override
           Nil: D:
Non-locking Push-turn
Base mounted

Manifold Exploded View


push type locking

Type 50, 51, 52


slotted
 Series  Pilot valve option type
3 SY3000 Nil Standard (102 psi (0.7 MPa))
5 SY5000 B Quick response type (102 psi (0.7 MPa))
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa))
E: F:
∗ Only metal seal type is available for the high
Push-turn Slide locking
 Type of actuation pressure type.
locking lever type

Connector Connecting Base


1 Single type
2
2-position
Double
 Coil type
3 Closed center Nil Standard
4 3-position Exhaust center T With power saving circuit (Continuous duty type)
5 Pressure center ∗ Be sure to select the power saving circuit type
∗ Refer to page 14 for with the safety slide locking
A∗ N.C./N.C. when the valve is continuously energized for
4-position manual override.
B∗ dual 3-port
N.O./N.O. long periods of time.
∗ Be careful of the energizing time when the
C∗ N.C./N.O.
∗ Only rubber seal type is available for the
power saving circuit is selected. Refer to page
244 for details.
 Type of mounting screw

Plug-in
4-position dual 3-port valve. Nil Round head combination screw
B Hexagon socket head cap screw
 Rated voltage
 Seal type 5 K
Round head combination screw

Manifold Exploded View


24 VDC (Falling-out-prevention type)
0 Rubber seal

Type 10, 11, 12


Hexagon socket head cap screw
1 Metal seal H (Falling-out-prevention type)
 Light/surge voltage suppressor
and common specification ∗For “K” and “H”, the valve body cover has a drop
 Pilot type Surge voltage Common
prevention construction to stop the mounting
Nil Internal pilot Symbol With light screws from falling out when the valve is
suppressor specification
R External pilot removed for maintenance etc.
R —
∗ When ordering a valve individually, the base
Non-polar
U  gasket is not included. Since the base gasket is
 Back pressure check valve S — Positive attached to the manifold, please order the base
Plug Assembly Part No.

 common
Z
One-touch Fittings/

(Built-in valve type)  gasket separately if it is needed for maintenance


Nil None NS — Negative service.
NZ  common Refer to page 73 for part numbers of the base
H Built-in
∗ Only “Z” and “NZ” types are available for with the gasket and mounting screw.
∗ Only rubber seal type ∗ “B” and “H” cannot be selected for the individual
∗ Back pressure check valve is not available for power saving circuit. Select a valve from R, U, S
or Z when the SI unit output polarity is Nil SUP/EXH spacer assembly, interface regulator
the 3-position type and the SY7000. or double check spacer assembly with residual
(positive common).
Manifold Options

Select a valve from R, U, NS or NZ when the SI pressure release valve.


unit output polarity is N (negative common).

Protective class
class III (Mark: )
58
Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Dimensions: Series SY3000 Metal Base EX510

U M5
SS5Y3-50(R)S5- Stations D - KC
C, N (D)
, KN
D side
L3
U side
B
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override

M5 x 0.8 (External pilot) DIN rail holding screw


45.1
(Pitch)
P = 10.5 (
Push-turn locking slotted type:
Press, then rotate it. )
18.5 19.6 (Light/surge 4(A) port side : Blue (For rubber seal)
[Pilot EXH port] (For DIN rail mounting)
voltage : Gray (For metal seal)
DIN rail bracket mounting screw suppressor) 2(B) port side : Yellow
(For DIN rail mounting)
DIN rail

B A B A B A B A B A

92.7
14 A 14 A 14 A 14 A 14 A
5EA

89
PE
16.8 17.2
79

15.9 16.2

5.5
64.4

35

56.9
21.8 16
1P
29.8

26.6
12 B 12 B 12 B 12 B 12 B
3EB

8.6 4 x ø4.5 SI unit 8


)

(For mounting)
Replaceable: 7.7

14.5 4 L2
22.1 (L5) L1
Fixed: 4.1

28 M5 x 0.8 (External pilot)


[External pilot port] (Station 1) --- (Station n)
1/8
(

[1(P), 5(EA), 3(EB) port]

manual override)
(Slide locking
50RS5- Stations UD

68.3
65.6

62.6
2B 2B

7.1

32
22.6
4A 4A

3
[Plug for external pilot]

(For DIN rail


2B
C2, C3: 5.4 One-touch fitting

mounting)
7.5
C4, C6: 6.6

11.8
4A [4(A), 2(B) port]
Applicable tube O.D.: ø2
C2, C3: 42.4 (Pitch) : ø3.2, ø1/8"
C4, C6: 41.8 P = 10.5 : ø4, ø5/32"
∗ The above drawing shows when P, E : ø6, ø1/4"
port entry is D.
Note) These figures show the “SS5Y3-50S5-05B-C6”.

Port size M5 One-touch fitting (Replaceable)

2B 2B
7.1
32

32
7.1
22.6

22.6

4A 4A

One-touch fitting
M5 x 0.8 [4(A), 2(B) port]
[4(A), 2(B) port] Applicable tube O.D.: ø2
6.6 (Pitch)
(Pitch) : ø3.2, ø1/8"
41.8 P = 10.5 : ø4, ø5/32"
48.4 P = 10.5
: ø6, ø1/4"

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17

59
Plug-in Metal Base Series SY3000/5000/7000

Valve
Plug-in Type 50/Side Ported

Dimensions: Series SY3000 Metal Base EX510

U
SS5Y3-50(R)S5- Stations D -01(D)

Sub-plate
B
D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override

Plug-in
M5 x 0.8 (External pilot)
[Pilot EXH port]
DIN rail holding screw 45.1
(Pitch)
P = 12.5 ( Push-turn locking slotted type:
Press, then rotate it. )
18.5 19.6 4(A) port side : Blue (For rubber seal)
(For DIN rail mounting) (Light/surge voltage : Gray (For metal seal)
suppressor) 2(B) port side : Yellow
DIN rail bracket mounting screw
(For DIN rail mounting)

DIN rail

Metal Base
B A B A B A B A B A

92.7
14 A 14 A 14 A 14 A 14 A
5EA

89
PE
16.8 17.2
79

15.9 16.2

5.5
64.4

35

56.9
16
1P
29.8

26.6
12 B 12 B 12 B 12 B 12 B
21.8
3EB

Plug-in
8.6 4 x ø4.5 SI unit 8
14.5 (For mounting) 4 L2
22.1 M5 x 0.8 (External pilot) (L5) L1
28 [External pilot port]

Manifold Exploded View


1/8

Type 50, 51, 52


[1(P), 5(EA), 3(EB) port]
(Station 1) ------ (Station n)

manual override)
(Slide locking
68.3
65.6

62.6
50RS5- Stations UD 2B 2B

7.1

Connector Connecting Base


32
22.6
4A 4A

(For DIN rail


[Plug for external pilot] 6.6 (Pitch) 1/8

mounting)
2B 41.8 P = 12.5 [4(A), 2(B) port] 7.5
4A
11.8

Plug-in
∗ The above drawing shows when P, E
port entry is D. Note) These figures show the “SS5Y3-50S5-05B-01”.

Manifold Exploded View


Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
Manifold Options

L3 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5
L4 100 112.5 125 137.5 150 162.5 175 187.5 200 212.5 225
L5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5

60
Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Dimensions: Series SY5000 Metal Base EX510

U 01
SS5Y5-50(R)S5- Stations D - KC
C, N (D)
, KN D side U side
B
L3
M5 x 0.8 (External pilot) 5.3 L4
Manual override
[Pilot EXH port] (DIN rail mounting hole pitch: 12.5)
DIN rail holding screw
50
(Pitch)
P = 16
(
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail bracket mounting screw 20.5 19.6 (Light/surge voltage : Gray (For metal seal)
(For DIN rail mounting) suppressor) 2(B) port side : Yellow

DIN rail
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
PE
5EA

106.2
5.5
23.2

116.6
35
96.2

20
81.6

20

74.1
1P
24.6
20

43.8
40.2

3EB

30.2
X

12 B 12 B 12 B 12 B 12 B

4 x ø4.5
)

12.3 SI unit
Replaceable: 8.5

(For mounting)
18 5 L2
28 (L5) L1
Fixed: 4.9

34 M5 x 0.8 (External pilot)


[External pilot port]
(

1/4
(Station 1) ----------- (Station n)
[1(P), 5(EA), 3(EB) port]

50RS5- Stations UD

manual override)
(Slide locking
74.3
71.6

68.6
3 2B 2B

[Plug for external pilot]

7.8

38
27.3
4A 4A
2B

4A

8.4

(For DIN rail


(Pitch) One-touch fitting
10

mounting)
45.8 P = 16 [4(A), 2(B) port]
∗ The above drawing shows when P, E Applicable tube O.D.: ø4, ø5/32" 14.3
port entry is D. : ø6, ø1/4"
: ø8, ø5/16"
Note) These figures show the “SS5Y5-50S5-05B-C8”.

Port size 01 One-touch fitting (Replaceable)

2B 2B
7.8

9.8
38

38
27.3

27.3

4A 4A

One-touch fitting
8.4 1/8 [4(A), 2(B) port]
(Pitch) Applicable tube O.D.: ø4, ø5/32"
[4(A), 2(B) port]
45.8 P = 16
(Pitch) : ø6, ø1/4"
51.6 P = 16 : ø8, ø5/16"

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5

61
Plug-in Metal Base Series SY3000/5000/7000

Valve
Plug-in Type 50/Side Ported

Dimensions: Series SY5000 Metal Base EX510

U
SS5Y5-50(R)S5- Stations D -02(D)

Sub-plate
B

D side U side
L3

Plug-in
M5 x 0.8 (External pilot)
5.3 L4
[Pilot EXH port] Manual override
(DIN rail mounting hole pitch: 12.5)
DIN rail holding screw
(For DIN rail mounting)
50
(Pitch)
P = 17.5
(
Push-turn locking slotted type:
Press, then rotate it. )
DIN rail bracket mounting screw 4(A) port side : Blue (For rubber seal)
20.5 19.6 (Light/surge voltage : Gray (For metal seal)
(For DIN rail mounting) suppressor)
2(B) port side : Yellow

Metal Base
DIN rail

B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
PE
5EA

106.2
5.5
23.2

116.6
35
96.2

20

Plug-in
81.6

20

74.1
1P
24.6
20

43.8
40.2

8
3EB

30.2
X

12 B 12 B 12 B 12 B 12 B

12.3 4 x ø4.5 SI unit

Manifold Exploded View


(For mounting)
L2

Type 50, 51, 52


18 5
28 (L5) L1
34 M5 x 0.8 (External pilot)
[External pilot port]
1/4
[1(P), 5(EA), 3(EB) port] (Station 1) ------------- (Station n)

Connector Connecting Base


manual override)
(Slide locking
50RS5- Stations UD

74.3
71.6

68.6
2B 2B
9.8

38
27.3
4A 4A
3
[Plug for external pilot]
2B
8.4 1/4 (For DIN rail
10

(Pitch) mounting)

Plug-in
4A
[4(A), 2(B) port]
14.3

45.8 P = 17.5

Manifold Exploded View


∗ The above drawing shows when P,

Type 10, 11, 12


E port entry is D. Note) These figures show the “SS5Y5-50S5-05B-02”.

Plug Assembly Part No.


One-touch Fittings/

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
Manifold Options

L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 123 135.5 148 173 185.5 210.5 223 235.5 260.5 273 298
L4 112.5 125 137.5 162.5 175 200 212.5 225 250 262.5 287.5
L5 17.5 15 12.5 16 13.5 17.5 15 12.5 16 13.5 17.5

62
Series SY3000/5000/7000

Plug-in Type 50/Side Ported

Dimensions: Series SY7000 Metal Base EX510

U 02
SS5Y7-50(R)S5- Stations D - KC
C, N (D)
, KN
D side
L3
U side
B
5.3 L4 Manual override
(DIN rail mounting hole pitch: 12.5)
(Pitch) (Push-turn locking slotted type:
Press, then rotate it. )
DIN rail holding screw 52 P = 19 4(A) port side : Blue (For rubber seal)
M5 x 0.8 (External pilot) (For DIN rail mounting) 20.5 19.6 (Light/surge voltage : Gray (For metal seal)
PE: Pilot EXH port suppressor) 2(B) port side : Yellow
DIN rail bracket mounting screw
(For DIN rail mounting)

(DIN rail)
BA BA BA BA B A

5.5
14 A 14 A 14 A 14 A 14 A
PE
5EA

116.7
23.8
28

35
102.1

133.2
92.1

84.6
24
1P
23.8
28.2

49.7
44.1

8
3EB
X

32.1
12 B 12 B 12 B 12 B 12 B

NC
NC
4 x ø4.5
18.1 SI unit
(5.4)

(For mounting)
20.9 5 L2
34.5 M5 x 0.8 (External pilot) (L5) L1
40.5 X: External pilot port
3/8 (Station 1) (Station n)
[1(P), 5(EA), 3(EB) port]

(Slide locking manual override)


50RS5- Stations UD

78.3
78.1

84
2B 2B

44.5
3

9.4
32.4
4A 4A
[Plug for external pilot]

2B

(For DIN rail


10.8 (Pitch)

10

mounting)
4A
46.6 P = 19

14.3
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D. : ø8, ø5/16"
∗ The above drawing shows when P, : ø10, ø3/8"
E port entry is D.
Note) These figures show the “SS5Y7-50S5-05B-C10”.

Port size 02 One-touch fitting (Replaceable)

2B 2B
44.5

44.5
10.3
9.4
32.4

31.5

4A 4A

10.8 (Pitch) (Pitch)


46.6 P = 19 55.7 P = 19
(11)
One-touch fitting
(22.9) [4(A), 2(B) port]
1/4 (For ø12) Applicable tube O.D. : ø6, ø1/4"
[4(A), 2(B) port] : ø8, ø5/16"
: ø10, ø3/8"
: ø12

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 123 148 160.5 185.5 198 223 235.5 260.5 273 298 310.5
L4 112.5 137.5 150 175 187.5 212.5 225 250 262.5 287.5 300
L5 15.5 18.5 15.5 18.5 15 18 15 18 14.5 17.5 14.5

63
Plug-in Metal Base Series SY3000/5000/7000

Valve
Plug-in Type 51/Bottom Ported

Dimensions: Series SY3000 Metal Base EX510

M5, 01
SS5Y3-51S5- Stations D- CKC, N, 
KN
 D side
45.1
(Pitch)
P = 10.5
U side
Manual override

Sub-plate
18.5 19.6 (Light/surge voltage
suppressor) (Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
: Gray (For metal seal)

Plug-in
2(B) port side : Yellow

B A B A B A B A B A

92.7
14 A 14 A 14 A 14 A 14 A

89
64.4

56.9
21.8 16
12 B 12 B 12 B 12 B 12 B

4 x ø4.5 SI unit
(For mounting)

Metal Base
(Max. 3) L1
(Station 1)--- (Station n)

manual override)
(Slide locking

Plug-in
Panel fitting dimensions

68.3
65.6

62.6
16 17.8 (For 9 stations or more)

32
2 x ø4.5
(For 9 stations or more)
4

(4.1)

Manifold Exploded View


40 (Pitch)
One-touch fitting
46.4 P = 10.5

Type 50, 51, 52


(For 9 stations or more) 4 x M4 x 0.7, thread depth 4 [4(A), 2(B) port]
(For mounting) 23.6 Applicable tube O.D.: ø2
4 x ø4.5
: ø3.2, ø1/8"

21.1
3EB 2B 2B
29.8

: ø4, ø5/32"
52.4
56.4

16.8 16.8

: ø6, ø1/4"

56.4
1P
4 x M4 x 0.7
4 x ø4.5 5EA 4A 4A
4 4
Fitting dimensions for panel mounting
L3 1/8
C2, C3, C4 : 16
: 15
Refer to panel fitting dimensions for details.

Connector Connecting Base


L2 [1(P), 5(EA), 3(EB) port]
2 x M4 x 0.7 L3 C6

(For 9 stations or more) L2 Note) These figures show the


“SS5Y3-51S5-05D-C6”.

Port size M5 Port size 01 One-touch fitting (Replaceable)

Plug-in
32

32

32

Manifold Exploded View


Type 10, 11, 12
(Pitch) (Pitch) (Pitch)
) C6: 12.8
N7: 16.6

46.4 P = 10.5 46.4 P = 12.5 46.4 P = 10.5


17 20.1

17 20.1
14 21.1

3EB 2B 3EB 2B 3EB 2B


29.8

29.8

29.8

1P 1P 1P

5EA 4A 5EA 4A 5EA 4A


Plug Assembly Part No.
One-touch Fittings/

M5 x 0.8 1/8 One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
: ø6, ø1/4"
Manifold Options

Port Size M5, C, N, KC, KN Port Size 01


n: Stations 2 3 4 5 6 7 8 9 10 11 12 n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5 L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5 L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 — — — — — — — 68.5 73.8 79 84.3 L3 — — — — — — — 77.8 84 90.3 96.5

64
Series SY3000/5000/7000

Plug-in Type 51/Bottom Ported

Dimensions: Series SY5000 Metal Base EX510

01, 02 D side (Pitch) U side


SS5Y5-51S5- Stations D - CKC, N, 
KN
 50 P = 16
Manual override
20.5 19.6 (Light/surge
voltage suppressor)
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
: Gray (For metal seal)
B A B A B A B A B A 2(B) port side : Yellow
14 A 14 A 14 A 14 A 14 A

106.2
116.6
81.6

74.1
20
30.2
12 B 12 B 12 B 12 B 12 B

4 x ø4.5
SI unit
(For mounting)
(Max. 3) L1
(Station 1) ----------- (Station n)

manual override)
(Slide locking
74.3
71.6

68.6
38
Panel fitting dimensions
2 x ø4.5
(For 9 stations or more) 4 x M4 x 0.7, thread depth 5

(4.9)
5

(Pitch) 2 x M4 x 0.7
4 x ø4.5 (For mounting) 50 P = 16
(For 9 stations or more)
20 25.2

24
One-touch fitting
61.6
71.6

[4(A), 2(B) port]


3EB 2B 2B
Applicable tube O.D.: ø4, ø5/32"
40.2

4 x M4 x 0.7
: ø6, ø1/4"
20

4 x ø4.5
: ø8, ø5/16"

71.6
1P
5 5
20

L3 5EA 4A 4A
L2 Fitting dimensions for panel mounting
Refer to panel fitting dimensions for details.
C4, C6 : 14.8
: 17.2

1/4
[1(P), 5(EA), 3(EB) port]
L3
L2 Note) These figures show the
C8

“SS5Y5-51S5-05D-C8”.

Port size 01 Port size 02 One-touch fitting (Replaceable)


38

38

38

(Pitch) (Pitch) (Pitch)


50 P = 16 50 P = 17.5 50 P = 16
(15.5)

3EB 2B 3EB 2B 3EB 2B


40.2

40.2

40.2
9.7

17.5

14.5
14.8

1P 1P 1P

5EA 4A 5EA 4A 5EA 4A

1/8 1/4 One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"

Port Size 01, C, N, KC, KN Port Size 02


n: Stations 2 3 4 5 6 7 8 9 10 11 12 n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244 L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 74 90 106 122 138 154 170 186 202 218 234 L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 — — — — — — — 93 101 109 117 L3 — — — — — — — 100.5 109.3 118 126.8

65
Plug-in Metal Base Series SY3000/5000/7000

Valve
Plug-in Type 51/Bottom Ported

Dimensions: Series SY7000 Metal Base EX510

02
SS5Y7-51(R)S5- Stations D- CKC, N, 
KN
(D) D side U side
Manual override

Sub-plate
(Light/surge voltage suppressor) (Push-turn locking slotted type:
Press, then rotate it. )
(Pitch) 4(A) port side : Blue (For rubber seal)
52 P = 19 : Gray (For metal seal)
20.5 19.6 2(B) port side : Yellow

Plug-in
4 x ø4.5
B A B A B A B A B A
(For mounting) 14 A 14 A 14 A 14 A 14 A

116.7
133.2
92.1

84.6
24
32.1

Metal Base
12 B 12 B 12 B 12 B 12 B

NC
NC
SI unit

Port size 02 One-touch fitting (Replaceable)

Plug-in
(For ø12)
(29.5)

Manifold Exploded View


(Station 1) (Station n)

Type 50, 51, 52


(Slide locking manual override)
(17.6)

78.3
78.1

84
44.5
One-touch fitting

Connector Connecting Base


[4(A), 2(B) port]

(5.4)
Applicable tube O.D. : ø6, ø1/4"
1/4 : ø8, ø5/16"
[4(A), 2(B) port] : ø10, ø3/8"
: ø12
32.8
33.1

3EB 2B 3EB 2B

4 x M4 x 0.7 thread depth 5


22.6
22

1P 1P
(For mounting)

Plug-in
3/8
[1(P), 5(EA), 3(EB) port]
5EA 4A 5EA 4A
(Pitch) M4 x 0.7 thread depth 5
(Max. 3) 52 P = 19

Manifold Exploded View


(For 9 stations or more)
27

Type 10, 11, 12


Fitting dimensions for panel mounting
5

Refer to panel fitting dimensions


for details.
33.1

2B 2B
Panel fitting dimensions
46.1

3EB
23

4 x ø4.5 2 x ø4.5
81.1

22

(For 9 stations or more) 1P


5

23
27.1

5EA 4A 4A
One-touch fitting
Plug Assembly Part No.
One-touch Fittings/
81.1
72.1

[4(A), 2(B) port]


24

Applicable tube O.D. C8 : ø8


L3 C10: ø10
4 x M4 x 0.7 N9 : ø5/16"
5 L2
4 x ø4.5 N11: ø3/8"
5 5 L1
L3
L2
Manifold Options

Note) These figures show the “SS5Y7-51S5-05D-C10”.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 — — — — — — — 107.5 117 126.5 136

66
Type 52 Plug-in Metal Base EX510
Top Ported

Series SY3000/5000/7000
How to Order Manifold

SS5Y 3 52 S5 05 D
       
 Series  Wiring type  Valve stations
3 SY3000 Nil All double wiring Note 1) Symbol Stations Note
5 SY5000 S All single wiring Note 2) 02 2 stations
All double
7 SY7000 Note 1) All double wiring: 2-position single, double, wiring
3-position and 4-position valves can be 08 8 stations
used on all manifold stations. 02 2 stations
All single
Note 2) All single wiring: Available only for the
 Type manifold which has 2-position single for all 12 12 stations
wiring

52 Top ported stations.


∗ This also includes the number of blanking plate
Note that 2-position double, 3- or 4-position
52R Top ported, External pilot assembly.
valves cannot be used.
Note 3) If a mix of single and double wiring is
required, it is supplied as a special order.
 SI unit output polarity  P, E port entry
U U side Note)
Nil Positive common
D D side Note)
N Negative common
B Both sides
Note) Plugs are mounted on the opposite side of
the selected ports.

How to Order Manifold Assembly  Thread type


Nil Rc
Example (SS5Y3-52S5-) 00F G
2-position double (24 VDC) 00N NPT
2-position single (24 VDC) SY3230-5U1-C6 (1 set) 00T NPTF
SY3130-5U1-C6 (3 sets)
3-position closed
center (24 VDC)
SY3330-5U1-C6 (1 set)  Mounting
Nil Direct mounting
DIN rail mounting
D (With DIN rail)
DIN rail mounting
D0 (Without DIN rail)
ide D3
Us For 3 stations
Specify a longer rail than the
standard length.
s
n
tio

D12 For 12 stations


ta
S

3 Note) Refer to page 247 for the fixation of DIN rail


2
1 mounting type manifold.
Manifold base ide
(5 stations) Ds
SS5Y3-52S5-05D

SS5Y3-52S5-05D ······1 set (Type 52 5-station manifold base part no.)


∗SY3130-5U1-C6 ·······3 sets (2-position single part no.)
∗SY3230-5U1-C6 ·······1 set (2-position double part no.)
∗SY3330-5U1-C6 ·······1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
For details on the EX510 Gateway-type Serial Transmission System,
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order refer to the WEB catalog or the Best Pneumatics No. 1 and the
from the 1st station as shown in the figure above. If the arrangement Operation Manual.
becomes complicated, specify on a manifold specification sheet. Please download the Operation Manual via SMC website,
http://www.smcworld.com

67
Plug-in Metal Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
            

Plug-in
Top ported

 Series  Coil type  A, B port size


3 SY3000 Nil Standard Thread piping
5 SY5000 T With power saving circuit (Continuous duty type) Symbol Port size Applicable series
7 SY7000 ∗ Be sure to select the power saving circuit type M5 M5 x 0.8 SY3000
when the valve is continuously energized for 01 1/8 SY5000

Metal Base
long periods of time. 02 1/4 SY7000
 Type of actuation ∗ Be careful of the energizing time when the
1 Single power saving circuit is selected. Refer to page One-touch fitting (Metric)
2-position 244 for details. Symbol A, B port SY3000 SY5000 SY7000
2 Double
3 Closed center C2 ø2  — —

Plug-in
C3 ø3.2  — —
4 3-position Exhaust center  Rated voltage C4 ø4   —
5 Pressure center
5 24 VDC C6
A∗ 4-position N.C./N.C. ø6   
B∗ dual N.O./N.O. C8 ø8 —  
C∗ 3-port C10 ø10 — — 
N.C./N.O.  Light/surge voltage suppressor C12 ø12 — —

Manifold Exploded View



∗ Only rubber seal type is available for the and common specification

Type 50, 51, 52


4-position dual 3-port valve. One-touch fitting (Inch)
Symbol Surge voltage Common
With light Symbol A, B port SY3000 SY5000 SY7000
suppressor specification
 Seal type R — N1 ø1/8"  — —
Non-polar N3 ø5/32"   —
0 Rubber seal
U 
S — Positive N7 ø1/4"   
1 Metal seal  N9 ø5/16" —  
Z  common
NS — Negative N11 ø3/8" — — 
 Pilot type NZ common

Connector Connecting Base



Nil Internal pilot ∗ Only “Z” and “NZ” types are available for with the  Thread type
R External pilot power saving circuit. Select a valve from R, U, S
or Z when the SI unit polarity is Nil (positive Nil Rc
common). Select a valve from R, U, NS or NZ F G
 Back pressure check valve when the SI unit output polarity is N (negative N NPT
common). T NPTF
(Built-in valve type)
Nil None ∗ Only Nil is available for M5.
H Built-in  Manual override
 Type of mounting screw

Plug-in
∗ Only rubber seal type Nil: D:
∗ Back pressure check valve is not available Non-locking Push-turn Nil Round head combination screw
for the 3-position type and the SY7000. push type locking B Hexagon socket head cap screw

Manifold Exploded View


slotted
Round head combination screw
K

Type 10, 11, 12


type
 Pilot valve option (Falling-out-prevention type)
Nil Standard (102 psi (0.7 MPa)) H Hexagon socket head cap screw
(Falling-out-prevention type)
B Quick response type (102 psi (0.7 MPa))
K∗ High pressure type (145 psi (1.0 MPa)) E: F: ∗ For “K” and “H”, the valve body cover has a drop
prevention construction to stop the mounting
∗ Only metal seal type is available for the high Push-turn Slide locking
screws from falling out when the valve is
pressure type. locking lever type removed for maintenance etc.
type ∗ When ordering a valve individually, the base
gasket is not included. Since the base gasket is
Plug Assembly Part No.
One-touch Fittings/

attached to the manifold, please order the base


gasket separately if it is needed for maintenance
service.
∗ Refer to page 14 for with the safety slide locking Refer to page 73 for part numbers of the base
manual override. gasket and mounting screw.
∗ "B" and "H" cannot be selected for the individual
SUP/EXH spacer assembly or interface
Manifold Options

regulator.

Protective class
class III (Mark: )

68
Series SY3000/5000/7000

Plug-in Type 52/Top Ported

Dimensions: Series SY3000 Metal Base EX510

D side U side

DIN rail holding screw L3


(For DIN rail mounting) 5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override
DIN rail bracket mounting screw

68.3
(For DIN rail mounting)
45.1
(Pitch)
P = 10.5 (
Push-turn locking slotted type:
Press, then rotate it. )
(Slide locking manual override) 18.5 19.6 (Light/surge voltage 4(A) port side : Blue (For rubber seal)
suppressor) : Gray (For metal seal)
M5 x 0.8 (External pilot) 2(B) port side : Yellow
[Pilot EXH port]
DIN rail

B A B A B A B A B A

92.7
4A 4A 4A 4A 4A
5EA

89
PE
16.8 17.2
79

15.9 16.2

5.5
35
64.4

56.9
16
1P
29.8

26.6
21.8

2B 2B 2B 2B 2B
3EB

8.6 4 x ø4.5 SI unit 8


14.5 (For mounting) One-touch fitting
4 L2
[4(A), 2(B) port]
22.1 (L5) L1 Applicable tube O.D.: ø2
28 : ø3.2, ø1/8"
M5 x 0.8
: ø4, ø5/32"
1/8 [4(A), 2(B) port] : ø6, ø1/4"
[1(P), 5(EA), 3(EB) port]
(Station 1) --- (Station n)
M5 x 0.8 (External pilot)
[External pilot port] ) C6: 76.8
N7: 80.6
65.6
62.6

(
32

52RS5- Stations UD
(For DIN rail
mounting)
7.5
11.8

3
[Plug for external pilot]

Note) These figures show the “SS5Y3-52S5-05B”.

∗ The above drawing shows when P, E


port entry is D.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17

69
Plug-in Metal Base Series SY3000/5000/7000

Valve
Plug-in Type 52/Top Ported

Dimensions: Series SY5000 Metal Base EX510

U
SS5Y5-52(R)S5- Stations D -(D)

Sub-plate
B

D side U side
L3

Plug-in
DIN rail holding screw 5.3 L4
(For DIN rail mounting) (DIN rail mounting hole pitch: 12.5) Manual override

( )
DIN rail bracket mounting screw (Pitch) Push-turn locking slotted type:
(For DIN rail mounting) 50 P = 16 Press, then rotate it.
74.3 20.5 19.6 4(A) port side : Blue (For rubber seal)
(Slide locking manual override) (Light/surge voltage : Gray (For metal seal)
M5 x 0.8 (External pilot) 68.6 suppressor) 2(B) port side : Yellow
[Pilot EXH port]

Metal Base
01 : 16.2
C : 14.5
DIN rail

5.5
B A B A B A B A B A
4A 4A 4A 4A 4A
PE
5EA

106.2

Plug-in
23.2

116.6
35
96.2

20
81.6

20

74.1
1P
24.6
20

43.8
40.2

40.2
3EB

8
30.2
X

2B 2B 2B 2B 2B

Manifold Exploded View


12.3 1/8

Type 50, 51, 52


18 4 x ø4.5 SI unit [4(A), 2(B) port]
(For mounting) One-touch fitting
28 5 L2
[4(A), 2(B) port]
34 (L5) L1 Applicable tube O.D.: ø4, ø5/32"
1/4 : ø6, ø1/4"
: ø8, ø5/16"
[1(P), 5(EA), 3(EB) port]
M5 x 0.8 (External pilot)

Connector Connecting Base


[External pilot port] (Station 1) ----------- (Station n) (86.7)

52RS5- Stations UD
72.3
71.6

38

Plug-in
3
[Plug for external pilot]
(For DIN rail
10

Manifold Exploded View


mounting)
14.3

Type 10, 11, 12


Note) These figures show the “SS5Y5-52S5-05B”.
∗ The above drawing shows when P, E
port entry is D.
Plug Assembly Part No.
One-touch Fittings/

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148
Manifold Options

164 180 196 212 228 244


L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5

70
Series SY3000/5000/7000

Plug-in Type 52/Top Ported

Dimensions: Series SY7000 Metal Base EX510

U
SS5Y7-52(R)S5- Stations D -(D)
B

D side U side

L3
5.3 L4 Manual override
M5 x 0.8 (External pilot)
PE: Pilot EXH port
(DIN rail mounting hole pitch: 12.5)
( Push-turn locking slotted type:
Press, then rotate it. )
DIN rail holding screw (Pitch) 4(A) port side : Blue (For rubber seal)
84 52 P = 19 : Gray (For metal seal)
(For DIN rail mounting)
(Slide locking manual override) 78.3 (Light/surge voltage 2(B) port side : Yellow
20.5 19.6
DIN rail bracket mounting screw suppressor)
(For DIN rail mounting)

(DIN rail) B A B A B A B A B A

5.5
4 A 4 A 4 A 4 A 4 A
PE
5EA

116.7
23.8
28
102.1

35

133.2
92.1

84.6
24
1P
23.8
28.2

49.7
45.6
44.1

22.6
8
3EB
X

32.1

2B 2B 2B 2B 2B

NC
NC
18.1 4 x ø4.5 1/4
20.9 (For mounting) [4(A), 2(B) port]
34.5 5 L2 One-touch fitting
40.5 (L5) L1 [4(A), 2(B) port]
Applicable tube O.D. : ø6, ø1/4"
3/8 : ø8, ø5/16"
[1(P), 5(EA), 3(EB) port] : ø10, ø3/8"
: ø12
M5 x 0.8 (External pilot)
X: External pilot port

(Station 1) (Station n)
U
52RS5- Stations D
(A, B port: ø12)

3
(110.3)

[Plug for external pilot]


(98.4)
87
78.1

44.5

(For DIN rail


10

mounting)

∗ The above drawing shows when P, E


14.3

port entry is D.

Note) These figures show the “SS5Y7-52S5-05B”.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 123 148 160.5 185.5 198 223 235.5 260.5 273 298 310.5
L4 112.5 137.5 150 175 187.5 212.5 225 250 262.5 287.5 300
L5 15.5 18.5 15.5 18.5 15 18 15 18 14.5 17.5 14.5

71
72
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Series SY3000/5000/7000 Type 50, 51, 52
Plug-in Metal Base Manifold Exploded View
q

Tightening torque: 1.03 lbf·ft (1.4 N·m)

Tightening torque: 1.03 lbf·ft (1.4 N·m) w

Holding screw

e It is mounted only for the DIN rail


mounting type (with DIN rail).

r It is mounted only for the DIN rail mounting type.


(Tightening torque of holding screw: 1.03 lbf·ft (1.4 N·m))
Caution Note) Refer to page 247 for the fixation of DIN rail
mounting type manifold.
Tightening torque
M2: 0.12 lbf ft (0.16 N·m) (SY3000)
M3: 0.59 lbf ft (0.8 N·m) (SY5000/7000)

Manifold Parts No.

Part no.
No. Description Note
SY3000 SY5000 SY7000
Round head SY3000-23-24A SY5000-221-1A SY7000-221-1A
combination screw (M2 x 32) (M3 x 32.5) (M3 x 36.5) Part numbers shown on the left are
Valve mounting
q for 10 valves (20 pcs.).
screw Hexagon socket SY3000-222-1A SY5000-222-1A SY7000-222-1A (30 pcs. for the SY7000)
head cap screw (M2 x 32) (M3 x 32.5) (M3 x 36.5)
Base gasket Part numbers shown on the left are
w (for plug-in metal base and sub-plate)
SY30M-11-1A SY50M-11-1A SY70M-11-1A for 10 valves (10 pcs.).
e DIN rail VZ1000-11-1- VZ1000-11-4- VZ1000-11-4- Refer to page 225.
Part numbers shown on the left are for
Clamp bracket assembly the clamp bracket assembly for one
r (for plug-in metal base) SY30M-15-2A SY50M-15-2A SY70M-15-2A
manifold (two sets of clamp brackets).

73
Type 50, 51, 52
Plug-in Metal Base Manifold Exploded View Series SY3000/5000/7000

Valve
Manifold Parts No.
 Blanking plate assembly (With mounting screw)

Sub-plate
Used when expecting valve additions, or for maintenance.
A structure to prevent screws falling out is in place on the blanking plate, making it much harder for the mounting screws to fall out.

Plug-in
Metal Base
SY30M-26-2A (-B) SY50M-26-2A (-B) SY70M-26-2A (-B)

Refer to pages 236, 238, 240 for dimensions.

Plug-in
Refer to pages 226 to 230 for individual SUP/EXH and other options.

Manifold Exploded View


How to Order Blanking Plate Assembly

Type 50, 51, 52


SY 0M 26 2 A
Series
3 SY3000 Option for mounting
5 SY5000 With mounting screw
7 SY7000 Nil (Round head combination screw)
With mounting screw

Connector Connecting Base


B (Hexagon socket head cap screw)
(A) (B)
4 2 Base type
2 For plug-in metal base

5 1 3
(EA) (P) (EB)
Circuit diagram

Plug-in
Manifold Exploded View
Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

74
75
Plug-in

Bottom ported
Side ported

Top ported
Connector Connecting Base

76
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Series SY3000/5000/7000 Type 10, 11, 12
Plug-in Connector Connecting Base
Manifold Specifications

D-sub Terminal Circular


Flat ribbon cable Lead wire Serial wiring
connector block box connector
Model PG type SA2 type S type
S6 type (EX500) S3 type
F type FW type P type J type PH type T type L type M type (EX250)
(EX600) S4 type (EX120)
G type (EX126) (EX260)

Manifold type Plug-in connector connecting base


SUP/EXH port type Common SUP/EXH (Common for 3/5 port)
2 to 18
stations 2 to 8 2 to 20 2 to 16 2 to 24 2 to 16
Valve stations 2 to 24 stations (J/G type: 2 to 24 stations
2 to 16 stations stations stations stations stations
stations)
D-sub Flat ribbon cable connector
connector with strain relief
Dedicated
Conforming to Conforming to MIL-C-83503
connector
Applicable connector MIL-C-24308 (Refer to page 97.) —
(Refer to
JIS-X-5101 Socket: Socket: Socket:
page 95.)
(Refer to 26 pins 20 pins 10 pins
page 95.) MIL type MIL type MIL type
Internal wiring Positive common, Negative common
ø8 One-touch fitting
SY3000
ø5/16" One-touch fitting
1(P), 3/5(E) ø10 One-touch fitting
port SY5000
ø3/8" One-touch fitting
ø12 One-touch fitting
SY7000
Port ø1/2" One-touch fitting
size ø2 One-touch fitting, ø3.2 One-touch fitting, ø4 One-touch fitting, ø6 One-touch fitting
SY3000
ø1/8" One-touch fitting, ø5/32" One-touch fitting, ø1/4" One-touch fitting
4(A), 2(B) ø4 One-touch fitting, ø6 One-touch fitting, ø8 One-touch fitting
port SY5000
ø5/32" One-touch fitting, ø1/4" One-touch fitting, ø5/16" One-touch fitting
ø6 One-touch fitting, ø8 One-touch fitting, ø10 One-touch fitting, ø12 One-touch fitting
SY7000
ø1/4" One-touch fitting, ø5/16" One-touch fitting, ø3/8" One-touch fitting
IP67∗ IP67∗
IP67∗

( )( )
Enclosure (Based on IEC60529) EX500
IP40 IP67∗ IP40 IP67∗ I/O unit:
gateway (Partially IP20
partially IP40)
IP40 unit, input
unit: IP65
∗ In the case of a metal seal, there are restrictions in the operating environment. Refer to the Specific Product Precautions (page 242).

77
Type 10, 11, 12
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Manifold Flow-rate Characteristics Note 1)/Manifold Weight
Valve Seal Type: Rubber Seal

Sub-plate
Port size Valve flow-rate characteristics
Weight: W [g] Note 2)
Model 1, 3/5 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→E)
(n: stations)
(P, E) (A, B) C [dm3/(s·bar)] b C [dm3/(s·bar)] b

Plug-in
SS5Y3-10 (Side ported) C8 C6 1.4 0.30 1.6 0.19 28.9n + 293
SS5Y3-12 (Top ported) C8 C6 1.2 0.29 1.3 0.19 25.1n + 314
SS5Y5-10 (Side ported) C10 C8 3.3 0.30 3.6 0.17 74.7n + 398
SS5Y5-11 (Bottom ported) C10 C8 3.3 0.29 4.2 0.26 76.8n + 445
SS5Y5-12 (Top ported) C10 C8 2.8 0.27 3.8 0.23 66.3n + 417
SS5Y7-10 (Side ported) C12 C12 6.2 0.23 5.9 0.20 106.6n + 496

Metal Base
SS5Y7-11 (Bottom ported) C12 C12 6.2 0.25 6.6 0.21 117.9n + 532
SS5Y7-12 (Top ported) C12 C12 5.6 0.31 5.7 0.24 84.1n + 519

Valve Seal Type: Metal Seal

Plug-in
Port size Valve flow-rate characteristics
Weight: W [g] Note 2)
Model 1, 3/5 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→E)
(n: stations)
(P, E) (A, B) C [dm3/(s·bar)] b C [dm3/(s·bar)] b
SS5Y3-10 (Side ported) C8 C6 1.2 0.19 1.3 0.18 28.9n + 293
SS5Y3-12 (Top ported)

Manifold Exploded View


C8 C6 1.2 0.16 1.3 0.18 25.1n + 314

Type 50, 51, 52


SS5Y5-10 (Side ported) C10 C8 2.7 0.24 3.1 0.17 74.7n + 398
SS5Y5-11 (Bottom ported) C10 C8 2.8 0.25 3.5 0.15 76.8n + 445
SS5Y5-12 (Top ported) C10 C8 2.6 0.18 3.0 0.16 66.3n + 417
SS5Y7-10 (Side ported) C12 C12 4.4 0.14 4.4 0.17 106.6n + 496
SS5Y7-11 (Bottom ported) C12 C12 4.6 0.16 4.7 0.18 117.9n + 532
SS5Y7-12 (Top ported) C12 C12 3.9 0.21 4.1 0.14 84.1n + 519

Connector Connecting Base


∗ Calculation of effective area S and sonic conductance C: S = 5.0 x C
Note 1) The value is for manifold base with 5 stations and individually operated 2-position type.
Note 2) Weight: W is the value of the internal pilot, and D-sub connector manifold with One-touch fitting straight piping type.
To obtain the weight with valves attached, add the valve weights given on page 5 for the appropriate number of stations.

Plug-in
Manifold Exploded View
Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

78
Series SY3000/5000/7000

Connector Wiring Layout


For both serial and parallel wiring, additional valves are sequentially assigned pins on the connector.
This makes it completely unnecessary to disassemble the connector unit.

 Single solenoid valve is installed to all double wiring. (in the case of all double wiring)
(Manifold specification sheet is not necessary.)
Solenoid Connector side
(D-sub connector etc.)

Common (+, –)
SOL.a
Station 1
SOL.b
SOL.a Station 2
Unused terminal
SOL.a Station 3
SOL.b

···
Double solenoid Single solenoid Double solenoid
Station 3 (Double wiring) Station 1
Station 2

 Single/double wiring are mixed.


(Manifold specification sheet is necessary.) Connector side
Solenoid
(D-sub connector etc.)

Common (+, –)
SOL.a Station 1
SOL.b
SOL.a Station 2
SOL.a
SOL.b Station 3
···

Double solenoid Single solenoid Double solenoid


Station 3 Station 2 Station 1

Note) These diagrams are for the purpose of explanation, and differ from the connector wiring used for testing.

79
80
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Type 10
Side Ported
Plug-in Connector Connecting Base
Type 11 D-sub Connector Flat Ribbon Cable PC Wiring

Series SY3000/5000/7000
Bottom Ported

RoHS
How to Order Manifold

Refer to pages 184 (SY5000) and SS5Y 3 10 F 1 05 U C6


185 (SY7000) for dimensions
of Type 11/Bottom ported type.         
 Series  Type  Connector type
3 SY3000 10 Side ported F: D-sub connector FW: D-sub connector <IP67> P: Flat ribbon cable PG: Flat ribbon cable
5 SY5000 11 Bottom ported∗ <IP40> New (25 pins) (26 pins) (20 pins)
7 SY7000 (25 pins)
∗ The SY5000 manifold base is used for
the bottom ported of the SY3000. When
ordering, refer to “Plug-in Mixed Mounting
Type Manifold” (from page 189). LOC
K
LOC
K
LOC
K
FRE FRE FRE
E E E

 Connector entry direction


∗ The connector entry di- PH: Flat ribbon cable J: PC wiring (20 pins) G: PC wiring (20 pins)
1: Upward 2: Lateral with power
rection for connector (10 pins) New supply terminal
Yellow ink
type "FW" D-sub con- Yellow ink
nector <IP67> can not
be rotated. If it is neces-
LOC
K
LOC
K sary to change, order LOC
K
LOC
K
FRE
E
FRE
E connector block assem- FRE
E
FRE
E

bly (page 208) sepa-


rately.
 Valve stations
F/FW: D-sub connector (25 pins) P: Flat ribbon cable (26 pins)
How to Order Manifold Assembly Symbol Stations
02 2 stations
Note Symbol Stations
02 2 stations
Note

Double wiring Note 1) Double wiring Note 1)


Example (SS5Y3-10F1-) 12 12 stations 12 12 stations
2-position double (24 VDC) 02 2 stations Specified layout Note 2) 02 2 stations Specified layout Note 2)
2-position single (24 VDC) SY3200-5U1 (1 set) (Available up to (Available up to
SY3100-5U1 (3 sets) 3-position closed 24 24 stations 24 solenoids) 24 24 stations 24 solenoids)
center (24 VDC)
SY3300-5U1 (1 set)
PG: Flat ribbon cable (20 pins) PH: Flat ribbon cable (10 pins)
Symbol Stations Note Symbol Stations Note
02 2 stations 02 2 stations
Double wiring Note 1) Double wiring Note 1)
LOC
09 9 stations 04 4 stations
K
ide 02 2 stations Specified layout Note 2) 02 2 stations Specified layout Note 2)
FRE Us
E s (Available up to (Available up to
on
ati 18 18 stations 18 solenoids) 08 8 stations 8 solenoids)
St
Manifold base 3
(5 stations) 2 J/G: PC wiring (20 pins) Note 1) Double wiring: 2-position single,
1
double, 3-position and 4-position
SS5Y3-10F1-05D-C6 ide Symbol Stations Note
Ds 02 2 stations valves can be used on all
manifold stations.
Double wiring Note 1)
SS5Y3-10F1-05D-C6 ···1 set (Type 10 5-station manifold base part no.) Use of a 2-position single
∗SY3100-5U1 ·················3 sets (2-position single part no.) 08 8 stations solenoid will result in an unused
∗SY3200-5U1 ·················1 set (2-position double part no.) 02 2 stations Specified layout Note 2) control signal. If this is not
∗SY3300-5U1 ·················1 set (3-position closed center part no.) (Available up to desired, order with a specified
16 16 stations 16 solenoids) layout.
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
Note 2) Specified layout: Indicate the wiring specifications on the manifold specification
• The valve arrangement is numbered as the 1st station from the D side. sheet. (Note that 2-position double, 3-position and 4- position valves cannot be
• Under the manifold part number, state the valves to be mounted in order from used where single wiring has been specified.)
the 1st station as shown in the figure above. If the arrangement becomes Note 3) This also includes the number of blanking plate assembly.
complicated, specify on a manifold specification sheet.
Note) When mixing top ported configurations, select from page 94.
In this case, use caution as there is also output on the A and B port on base side.
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side.

81
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
 P, E port entry  SUP/EXH block assembly  Mounting and Option

Sub-plate
U U side (2 to 10 stations) Nil Internal pilot Option DIN Rail Option
Symbol Mounting
D D side (2 to 10 stations) Internal pilot, Name plate Station number Nil Direct mounting
S
B Both sides (2 to 24 stations) Built-in silencer Nil — — 0 Without DIN rail (with bracket)
Direct

Plug-in
R External pilot AA mounting   3 For 3 stations Specify a longer rail
∗ 3/5(E) port is plugged for the BA  — than the total length
built-in silencer type. D — — 24 For 24 stations of specified stations.
DIN rail
A mounting  
B  —
Note 1) Enter the number of stations inside  when it is larger than the
number of valve stations. (Refer to “DIN Rail Option” above.)
Note 2) Only direct mounting is available for Type 11 (Bottom ported).

Metal Base
Note 3) Refer to page 247 for the fixation of DIN rail mounting type manifold.

 A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)

Plug-in
Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2  — — — — N1 ø1/8"  — — — —
C3 ø3.2  — — — — N3 ø5/32"   —  —

Straight
C4 ø4   —  — N7 ø1/4"     

Manifold Exploded View


Straight

C6 ø6      N9 ø5/16" —    

Type 50, 51, 52


C8 ø8 —     N11 ø3/8" — —  — 
C10 ø10 — —  —  CM∗ Straight port, mixed sizes     
C12 ø12 — —  —  LN3 ø5/32"  — — — —
CM∗
Upward

Straight port, mixed sizes      LN7 ø1/4"   — — —


L4 ø4   — — — LN9 ø5/16" —  — — —
L6 ø6    — — LN11 ø3/8" — —  — —
Upward

Elbow Note)

Connector Connecting Base


L8 ø8 —   — — BN3 ø5/32"  — — — —
Downward

L10 ø10 — —  — — BN7 ø1/4"   — — —


L12 ø12 — —  — — BN9 ø5/16" —  — — —
Elbow Note)

B4 ø4   — — — BN11 ø3/8" — —  — —
Downward

B6 ø6    — — Elbow port, mixed sizes


LM∗ (Including upward and    — —
B8 ø8 —   — — downward piping)
B10 ø10 — —  — — P, E port size
ø5/16" ø3/8" ø1/2" ø3/8" ø1/2"
B12 ø12 — —  — — (One-touch fittings)

Plug-in
Elbow port, mixed sizes
LM∗ (Including upward and    — —
downward piping)

P, E port size

Manifold Exploded View


ø8 ø10 ø12 ø10 ø12
(One-touch fittings)

Type 10, 11, 12


Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 226 to 228).
∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting direction.

Plug Assembly Part No.


One-touch Fittings/
Manifold Options

Protective class
class III (Mark: )

82
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 0 0 5 1
          
Base mounted

 Series  Pilot valve option  Manual override


3 SY3000 Nil Standard (102 psi (0.7 MPa)) Nil: D:
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Non-locking Push-turn
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa)) push type locking
∗ Only metal seal type is available for the high slotted
pressure type. type

 Type of actuation
1 Single E: F:
2
2-position
Double  Coil type Push-turn Slide locking
3 Closed center Nil Standard locking lever type
4 3-position Exhaust center T With power saving circuit (Continuous duty type) type
5 Pressure center ∗ Be sure to select the power saving circuit type
A∗ 4-position N.C./N.C. when the valve is continuously energized for
B∗ dual N.O./N.O. long periods of time.
C∗ 3-port N.C./N.O. ∗ Be careful of the energizing time when the ∗ Refer to page 14 for with the safety slide locking
power saving circuit is selected. Refer to page manual override.
∗ Only rubber seal type is available for the 244 for details.
4-position dual 3-port valve.

 Rated voltage  Type of mounting screw


 Seal type Nil Round head combination screw
5 24 VDC
0 Rubber seal B Hexagon socket head cap screw
6 12 VDC
1 Metal seal Round head combination screw
∗ Connector type "G" (PC wiring with power K (Falling-out-prevention type)
supply terminal) of the manifold type is only
Hexagon socket head cap screw
available in 24 VDC. H (Falling-out-prevention type)
 Pilot type ∗ For “K” and “H”, the valve body cover has a drop
Nil Internal pilot prevention construction to stop the mounting
R External pilot  Light/surge voltage suppressor screws from falling out when the valve is
and common specification removed for maintenance etc.
∗ When ordering a valve individually, the base
Surge voltage Common
Symbol With light gasket is not included. Since the base gasket is
suppressor specification
 Back pressure check valve (Built-in valve type) Nil — —
attached to the manifold, please order the base
gasket separately if it is needed for maintenance
Nil None R — Non-polar service.
H Built-in U  Refer to page 220 for part numbers of the base
∗ Only rubber seal type. Manifold installed type is S — Positive gasket and mounting screw.
available if the back pressure check valve is  common ∗ “B” and “H” cannot be selected for the individual
Z 
required for a valve with metal seal. Refer to SUP/EXH spacer assembly, interface regulator
page 232 for Ordering Example. However, it is
NS — Negative or double check spacer assembly with residual
NZ  common pressure release valve.
not recommended to use the built-in valve type
and the manifold installed type at the same time ∗ Only “Z” and “NZ” types are available for with the
because it will reduce the flow. power saving circuit.
∗ The built-in valve type back pressure check ∗ For connector type "G" (PC wiring with power
valve is not available for the 3-position type and supply terminal) of the manifold type, select
the SY7000. non-polar or positive common.

Protective class
class III (Mark: )

83
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY3000 Connector Connecting Base D-sub Connector (IP40)

C2
U
SS5Y3-10F 21 - Stations D - C3,
C4, N3 (D)
N1

Sub-plate
B C6, N7
D side U side
Manual override Note 2)
DIN rail holding screw (L5) L1
(Push-turn locking slotted type:
)

Plug-in
(For DIN rail mounting) (8) Press, then rotate it.
4(A) port side : Blue (For rubber seal)
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent (Light/surge voltage suppressor) : Gray (For metal seal)
2(B) port side : Yellow

(5.5)
(8)
LOCK

B A B A B A B A B A

(35)

92.6
14 A 14 A 14 A 14 A 14 A

70.6
83

Metal Base
60.5
FREE

(40.9)
44.8

4.6
12 B 12 B 12 B 12 B 12 B

Plug-in
2 x M2.6
4.6
9.5

1.7
(4.9)

)
2 x 4-40 UNC

C6: 3.6
N7: 7.4
(Connector entry
[4(A), 2(B) port: 4 x M4 mounting hole
N (inch size)] upward direction)
(Fitting for the type with P/E

(
19.6 L2 1.5 ports on the U and/or D sides)
(L4)

Manifold Exploded View


(5.3)

Type 50, 51, 52


(DIN rail mounting hole pitch: 12.5)
(L3)
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø2
(Station 1) --- (Station n) : ø3.2, ø1/8"
6.1 : ø4, ø5/32"
: ø6, ø1/4"

Connector Connecting Base


1 P 1 P
(62.7)

63.1
13.6
10.6
56.6
48.6

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

21.6
4 A4 A4 A4 A4 A
18

(For DIN rail


mounting)
(7.5)

One-touch fitting (Pitch)


(11.8)

[1(P), 3/5(E) port] 31.4 15.5 P = 10.5 (17.8)

Plug-in
Applicable tube O.D.: ø8, ø5/16"

Manifold Exploded View


Type 10, 11, 12
Note 1) These figures show the “SS5Y3-10F2-05D-C6”.
Note 2) Refer to page 181 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 186 for dimensions of A or B port top-ported type.
Plug Assembly Part No.
One-touch Fittings/

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1
Manifold Options

88.6 99.1 109.6 120.1 130.6 141.1 151.6 162.1 172.6 183.1 193.6 204.1 214.6 225.1 235.6 246.1 256.6 267.1 277.6 288.1 298.6 309.1 319.6
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 123 135.5 148 160.5 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 298 298 310.5 323 335.5 348 360.5
L4 112.5 125 137.5 150 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275 287.5 287.5 300 312.5 325 337.5 350
L5 20.5 21.5 22.5 23.5 18 19 20 21 22 23 18 19 20 21 22 23 23.5 18.5 19.5 20.5 21.5 22.5 23.5

84
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base D-sub Connector (IP40)

U C4, N3
SS5Y5-10F 21 - Stations D - C6, N7 (D)
B C8, N9

D side U side
Manual override Note 2)
(L5) L1
DIN rail holding screw
(For DIN rail mounting) (8)
( Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent
DIN rail
(Light/surge voltage suppressor)
: Gray (For metal seal)
2(B) port side : Yellow

(5.5)
(8)
LOCK

BA BA BA BA BA

(35)
14 A 14 A 14 A 14 A 14 A
70.6
97.5

113.4
FREE

81.2
(61.7)
65.6

5.5
12 B 12 B 12 B 12 B 12 B
10.9
30.3

4.7
2 x M2.6
(5.9)
(8.3)

4 x M5 mounting hole
2 x 4-40 UNC
[4(A), 2(B) port: 21.9 L2 1.5 (Fitting for the type with P/E
N (inch size)] ports on the U and/or D sides)
(5.3) (L4)
(Connector entry upward direction) (DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting
[4(A), 2(B) port]
(Station 1) ----------- (Station n) Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"
6.1

1 P 1 P
14.1

73.2
(62.7)

8.7

2 B2 B2 B2 B2 B
56.6
48.6

12.4

3/5 E 3/5 E
33.4

29.1

4 A4 A4 A4 A4 A

One-touch fitting
(For DIN rail

(Pitch)
(7.5)

mounting)

[1(P), 3/5(E) port]


(11.8)

Applicable tube O.D.: ø10, ø3/8" 35.9 18 P = 16 (20.5)

Note 1) These figures show the “SS5Y5-10F2-05D-C8”.


Note 2) Refer to page 182 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 187 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 108.4 124.4 140.4 156.4 172.4 188.4 204.4 220.4 236.4 252.4 268.4 284.4 300.4 316.4 332.4 348.4 364.4 380.4 396.4 412.4 428.4 444.4 460.4
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 148 160.5 173 198 210.5 223 235.5 260.5 273 285.5 298 323 335.5 348 373 385.5 398 410.5 435.5 448 460.5 485.5 498
L4 137.5 150 162.5 187.5 200 212.5 225 250 262.5 275 287.5 312.5 325 337.5 362.5 375 387.5 400 425 437.5 450 475 487.5
L5 23 21 19.5 24 22 20.5 18.5 23 21.5 19.5 18 22.5 20.5 19 23.5 21.5 20 18 22.5 21 19 23.5 22

85
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY7000 Connector Connecting Base D-sub Connector (IP40)

U C6, N7
C10, N11(D)
SS5Y7-10F 12- Stations DB - C8, N9

Sub-plate
C12
D side U side
Manual override Note 2)
DIN rail holding screw (L5) L1
(Push-turn locking slotted type:
)

Plug-in
(For DIN rail mounting) Press, then rotate it.
(8)

(
JIS-X-5101
Applicable connector: D-sub MIL-C-24308 equivalent ) (Light/surge voltage suppressor)
4(A) port side : Blue (For rubber seal)
: Gray (For metal seal)
2(B) port side : Yellow

(8)
(DIN rail)
LOCK

B A B A B A B A B A

(35)

Metal Base
14 A 14 A 14 A 14 A 14 A
70.6

128.8
115
FREE

(5.5)

96.7
(77.1)
79.5

Plug-in
12 B 12 B 12 B 12 B 12 B
44.2

5.5
8.8

2 x M2.6

3.9
(6)
(9.3)

Manifold Exploded View


2 x 4-40 UNC
(A, B port: ø12)
(17.9)

4 x M5 mounting hole

Type 50, 51, 52


[4(A), 2(B) port: N (inch size)]
20.7 L2 1.5 (Fitting for the type with P/E
(Connector entry upward direction) ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting
[4(A), 2(B) port]

Connector Connecting Base


Applicable tube O.D.: ø6, ø1/4"
(Station 1) (Station n) : ø8, ø5/16"
: ø10, ø3/8"
: ø12
6.1

2
1 P 1 P
2 B2 B2 B2 B2 B 82.7
(62.7)

Plug-in
56.6
48.6

14.2

3/5 E 3/5 E
11.1
8.7
35.2

31.6

4 A4 A4 A4 A4 A

Manifold Exploded View


Type 10, 11, 12
(Pitch)
(For DIN rail

One-touch fitting (21.7)


(10)

mounting)

39.5 20.5 P = 19
(14.3)

[1(P), 3/5(E) port]


Applicable tube O.D.: ø12, ø1/2"

Note 1) These figures show the “SS5Y7-10F2-05D-C10”.


Note 2) Refer to page 183 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Plug Assembly Part No.

Note 3) Refer to page 188 for dimensions of A or B port top-ported type.


One-touch Fittings/

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Manifold Options

L1 121.2 140.2 159.2 178.2 197.2 216.2 235.2 254.2 273.2 292.2 311.2 330.2 349.2 368.2 387.2 406.2 425.2 444.2 463.2 482.2 501.2 520.2 539.2
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 160.5 173 198 210.5 235.5 248 273 285.5 310.5 323 348 360.5 385.5 398 423 435.5 460.5 485.5 498 523 535.5 560.5 573
L4 150 162.5 187.5 200 225 237.5 262.5 275 300 312.5 337.5 350 375 387.5 412.5 425 450 475 487.5 512.5 525 550 562.5
L5 22.5 19.5 22.5 19 22 19 22 18.5 21.5 18.5 21.5 18 21 18 21 17.5 20.5 23.5 20.5 23.5 20 23 20

86
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY3000 Connector Connecting Base D-sub Connector (IP67)

U C2
SS5Y3-10FW 12 - C4, N3 (D)
Stations D - C3, N1
B C6, N7
D side U side
(L5) Manual override Note 2)
L1
DIN rail holding screw
(15)
(Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor) : Gray (For metal seal)
(Connector entry upward direction)
2(B) port side : Yellow

DIN rail

(8)

(5.5)
B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A

92.6
83
70.6

60.5
(40.9)
38.7

12 B 12 B 12 B 12 B 12 B

4.6
3.4

4.6
1.7
(4.9)

)C6: 3.6
N7: 7.4

2 x M2.6
2 x 4-40 UNC 4 x M4 mounting hole
(

[4(A), 2(B) port: N (inch size)]


36.5 L2 1.5 (Fitting for the type with P/E
ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
Applicable connector: D-sub
( JIS-X-5101
MIL-C-24308 )
equivalent (L3)

(Station 1) (Station n)
One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: ø2, ø1/8"
Applicable tube O.D.: ø8, ø5/16" : ø3, ø5/32"
4.5 : ø4, ø1/4"
: ø6

1 P 1 P
(61.1)

63.1
56.6

10.6
13.6

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

4 A4 A4 A4 A4 A
21.6
23
18

(17.8)
(For DIN rail
(7.5)

(Pitch)
mounting)
(11.8)

48.3 15.5 P=10.5

Note 1) These figures show the “SS5Y3-10FW2-05D-C6”.


Note 2) Refer to page 181 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 186 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 105.5 116 126.5 137 147.5 158 168.5 179 189.5 200 210.5 221 231.5 242 252.5 263 273.5 284 294.5 305 315.5 326 336.5
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 135.5 148 160.5 173 185.5 198 198 210.5 223 235.5 248 260.5 260.5 273 285.5 298 310.5 323 323 335.5 348 360.5 373
L4 125 137.5 150 162.5 175 187.5 187.5 200 212.5 225 237.5 250 250 262.5 275 287.5 300 312.5 312.5 325 337.5 350 362.5
L5 17.5 18.5 19.5 20.5 21.5 22.5 17 18 19 20 21 22 17 18 19 20 21 22 16.5 17.5 18.5 19.5 20.5

87
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base D-sub Connector (IP67)

U C4, N3
SS5Y5-10FW 12 - Stations D- C6, N7 (D)

Sub-plate
B C8, N9
D side U side
Manual override Note 2)
(L5) L1
(
Push-turn locking slotted type:
Press, then rotate it. )

Plug-in
DIN rail holding screw
(15) 4(A) port side : Blue (For rubber seal)
(For DIN rail mounting) (Light/surge voltage suppressor)
(Connector entry upward direction) : Gray (For metal seal)
2(B) port side : Yellow
DIN rail
(8)

(5.5)
B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A

Metal Base
97.5
70.6

113.4
81.2
(61.7)
59.5

5.5
12 B 12 B 12 B 12 B 12 B
24.2

Plug-in
10.9
4.7
2 x M2.6 (5.9)
(8.3)

2 x 4-40 UNC 4 x M5 mounting hole


[4(A), 2(B) port: 36 L2 1.5
(Fitting for the type with P/E

Manifold Exploded View


N (inch size)] (5.3) (L4)
ports on the U and/or D sides)

Type 50, 51, 52


(DIN rail mounting hole pitch: 12.5)
( )
Applicable connector: D-sub JIS-X-5101 equivalent
MIL-C-24308 (L3)

(Station 1) (Station n)
One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: ø4, ø5/32"

Connector Connecting Base


Applicable tube O.D.: ø10, ø3/8" : ø6, ø1/4"
: ø8, ø5/16"
4.5

1 P 1 P
14.1

73.2
8.7
(61.1)

2 B2 B2 B2 B2 B
56.6

3/5 E 3/5 E
33.4

29.1
23

4 A4 A4 A4 A4 A

Plug-in
12.4

(For DIN rail

(Pitch)
(7.5)

mounting)

50 18 P=16 (20.5)
(11.8)

Manifold Exploded View


Type 10, 11, 12

Note 1) These figures show the “SS5Y5-10FW2-05D-C8”.


Note 2) Refer to page 182 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Plug Assembly Part No.
One-touch Fittings/

Note 3) Refer to page 187 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Manifold Options

L1 122.5 138.5 154.5 170.5 186.5 202.5 218.5 234.5 250.5 266.5 282.5 298.5 314.5 330.5 346.5 362.5 378.5 394.5 410.5 426.5 442.5 458.5 474.5
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 160.5 173 185.5 210.5 223 235.5 248 273 285.5 298 310.5 335.5 348 360.5 385.5 398 410.5 423 448 460.5 473 498 510.5
L4 150 162.5 175 200 212.5 225 237.5 262.5 275 287.5 300 325 337.5 350 375 387.5 400 412.5 437.5 450 462.5 487.5 500
L5 21.5 19.5 18 22.5 20.5 19 17 21.5 20 18 16.5 21 19 17.5 22 20 18.5 16.5 21 19.5 17.5 22 20.5

88
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY7000 Connector Connecting Base D-sub Connector (IP67)

U C6, N7
SS5Y7-10FW 12 - Stations D - C8, N9 (D)
B C10, N11
C12
D side U side

Manual override Note 2)


(L5) L1
DIN rail holding screw
(For DIN rail mounting) (15) (Push-turn locking slotted type:
Press, then rotate it. )
(Light/surge voltage suppressor) 4(A) port side : Blue (For rubber seal)
(Connector entry upward direction) : Gray (For metal seal)
2(B) port side : Yellow

(8)
(DIN rail)
B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A
70.6

128.8
115

(5.5)

96.7
(77.1)
74.9

12 B 12 B 12 B 12 B 12 B

5.5
39.6
8.8

3.9
(6)
(9.3)

2 x M2.6
(17.9)

2 x 4-40 UNC (A, B port: ø12) 4 x M5 mounting hole


[4(A), 2(B) port: N (inch size)]
36.2 L2 1.5 (Fitting for the type with P/E
(5.3) (L4) ports on the U and/or D sides)
Applicable connector: D-sub
( JIS-X-5101
MIL-C-24308)equivalent (DIN rail mounting hole pitch: 12.5)
(L3)

(Station 1) (Station n) One-touch fitting


[4(A), 2(B) port]
Applicable tube O.D.: ø6, ø1/4"
One-touch fitting : ø8, ø5/16"
[1(P), 3/5(E) port] : ø10, ø3/8"
Applicable tube O.D.: ø12, ø1/2" : ø12
4.5
2

1 P 1 P
82.7

2 B2 B2 B2 B2 B
(61.1)

56.6

3/5 E 3/5 E
11.1
8.7
35.2

31.6

4 A4 A4 A4 A4 A
23
14.2

(For DIN rail

(Pitch) (21.7)
(10)

mounting)
(14.3)

55 20.5 P = 19

Note 1) These figures show the “SS5Y7-10FW2-05D-C10”.


Note 2) Refer to page 183 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 188 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 136.7 155.7 174.7 193.7 212.7 231.7 250.7 269.7 288.7 307.7 326.7 345.7 364.7 383.7 402.7 421.7 440.7 459.7 478.7 497.7 516.7 535.7 554.7
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 173 185.5 210.5 223 248 260.5 285.5 298 323 335.5 360.5 385.5 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5
L4 162.5 175 200 212.5 237.5 250 275 287.5 312.5 325 350 375 387.5 412.5 425 450 462.5 487.5 500 525 537.5 562.5 575
L5 20.5 17 20 17 20 16.5 19.5 16.5 19.5 16 19 22 19 22 18.5 21.5 18.5 21.5 18 21 18 21 17.5

89
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY3000 Connector Connecting Base Flat Ribbon Cable

P C2
U D side U side
PH 2 - Stations D - C4, N3 (D)
SS5Y3-10 PG 1 C3, N1

Sub-plate
B C6, N7 (L5) L1 Manual override Note 2)
J

(Connector entry upward direction)


DIN rail holding screw (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
(Light/surge : Gray (For metal seal)
Triangle mark DIN rail (8)

Plug-in
2(B) port side : Yellow
voltage suppressor)

(8)

(5.5)
LOCK

B A B A B A B A B A

(35)

92.6
14 A 14 A 14 A 14 A 14 A

70.6
83

60.5
FREE

(40.9)
44.8

Metal Base
4.6
12 B 12 B 12 B 12 B 12 B
4.6
9.5

N7: 7.4 )

1.7
(4.9)
(Fitting for the type

3.6
Applicable connector:
with P/E ports on the

(C6:
26 pins MIL type with strain relief

Plug-in
U and/or D sides)
(Conforming to MIL-C-83503) 19.6 L2 1.5 4 x M4 mounting hole
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)
For PC wiring with power One-touch fitting

Manifold Exploded View


supply terminals (Station 1)---(Station n) [4(A), 2(B) port]

Type 50, 51, 52


Applicable tube O.D.: ø2
18.8
: ø3.2, ø1/8"
: ø4, ø5/32"
1 P 1 P
: ø6, ø1/4"
(75.4)

63.1
10.6
13.6
56.6
48.6

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

4 A4 A4 A4 A4 A

21.6
18

Connector Connecting Base


(Pitch)

(For DIN rail


(7.5)
One-touch fitting 7.9 31.4 15.5 P=10.5 (17.8)

mounting)
[1(P), 3/5(E) port] (11.8)
Applicable tube O.D.: ø8, ø5/16"

Note 1) These figures show the “SS5Y3-10P2-05D-C6”.


Note 2) Refer to page 181 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 186 for dimensions of A or B port top-ported type.
Note 4) Only connectors are different for 10PG, 10PH, 10J and 10G. L1 to L5 dimensions are the same as 10P type.

Plug-in
10PJG (20 pins) 10PH (10 pins) 10G (20 pins)
For PC wiring Switch for locking a connector

Manifold Exploded View


Triangle mark Triangle mark LED Triangle mark

Type 10, 11, 12


Power supply terminal
( 24 VDC
+COM )
− (Negative)
LOCK

+ (Positive)
LOCK

LOCK
PCW type

(M3 terminal screw)


FREE
FREE

FREE

44.8

Plug Assembly Part No.


One-touch Fittings/

Applicable connector: Applicable connector: Applicable connector: 20 pins


20 pins MIL type with strain relief 10 pins MIL type with strain relief MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Manifold Options

L1 88.6 99.1 109.6 120.1 130.6 141.1 151.6 162.1 172.6 183.1 193.6 204.1 214.6 225.1 235.6 246.1 256.6 267.1 277.6 288.1 298.6 309.1 319.6
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 123 135.5 148 160.5 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 298 298 310.5 323 335.5 348 360.5
L4 112.5 125 137.5 150 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275 287.5 287.5 300 312.5 325 337.5 350
L5 20.5 21.5 22.5 23.5 18 19 20 21 22 23 18 19 20 21 22 23 23.5 18.5 19.5 20.5 21.5 22.5 23.5

90
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base Flat Ribbon Cable

P
U C4, N3
PH 2 - Stations D - C6, N7 (D)
SS5Y5-10 PG 1 D side U side
J B C8, N9 (L5) L1 Manual override Note 2)

(Connector entry upward direction)


DIN rail holding screw
(For DIN rail mounting)
(8) (Push-turn locking slotted type:
Press, then rotate it. )
(Light/surge voltage suppressor) 4(A) port side : Blue (For rubber seal)
Triangle mark DIN rail : Gray (For metal seal)
2(B) port side : Yellow

(5.5)
(8)
LOCK

BA BA BA BA BA

(35)
14 A 14 A 14 A 14 A 14 A

70.6
97.5

113.4
FREE

81.2
(61.7)
65.6

5.5
12 B 12 B 12 B 12 B 12 B
30.3
10.9

4 x M5 mounting hole

4.7
(5.9)
(8.3)
Applicable connector: (Fitting for the type with P/E
26 pins MIL type with strain relief 21.9 L2 1.5
ports on the U and/or D sides)
(Conforming to MIL-C-83503) (5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3) One-touch fitting
For PC wiring with power
supply terminals [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
(Station 1)----------- (Station n) : ø6, ø1/4"
: ø8, ø5/16"
18.8
(75.4)

1 P 1 P

14.1

73.2
8.7
2 B2 B2 B2 B2 B
56.6
48.6

12.4

3/5 E 3/5 E
33.4

29.1
4 A4 A4 A4 A4 A

(For DIN rail


One-touch fitting
(7.5)

(Pitch)

mounting)
(11.8)
[1(P), 3/5(E) port] 7.9 35.9 18 P=16 (20.5)
Applicable tube O.D.: ø10, ø3/8"

10PJG (20 pins) 10PH (10 pins) 10G (20 pins)


For PC wiring Switch for locking a connector
Note 1) These figures show the Triangle mark
LED
“SS5Y5-10P2-05D-C8”. Triangle mark Triangle mark
Power supply terminal
Note 2) Refer to page 182 for
dimensions of external ( 24 VDC
+COM )
pilot, silencer, elbow −(Negative)
LOCK

+(Positive)
LOCK

fittings and slide locking


LOCK
PCW type

manual override. (M3 terminal screw)


Note 3) Refer to page 187 for
FREE
FREE

dimensions of A or B port
FREE

top-ported type.
65.6

Note 4) Only connectors are


different for 10PG, 10PH
and 10J.
L1 to L5 dimensions are
the same as 10P type.
Applicable connector: Applicable connector: Applicable connector: 20 pins
20 pins MIL type with strain relief 10 pins MIL type with strain relief MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 108.4 124.4 140.4 156.4 172.4 188.4 204.4 220.4 236.4 252.4 268.4 284.4 300.4 316.4 332.4 348.4 364.4 380.4 396.4 412.4 428.4 444.4 460.4
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 148 160.5 173 198 210.5 223 235.5 260.5 273 285.5 298 323 335.5 348 373 385.5 398 410.5 435.5 448 460.5 485.5 498
L4 137.5 150 162.5 187.5 200 212.5 225 250 262.5 275 287.5 312.5 325 337.5 362.5 375 387.5 400 425 437.5 450 475 487.5
L5 23 21 19.5 24 22 20.5 18.5 23 21.5 19.5 18 22.5 20.5 19 23.5 21.5 20 18 22.5 21 19 23.5 22

91
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY7000 Connector Connecting Base Flat Ribbon Cable


P
PG U C6, N7
SS5Y7-10 PH D 12 - Stations DB - C8,
C10, N11 (D)
N9 D side U side Manual override Note 2)

Sub-plate
J
G C12
DIN rail holding screw
(L5) L1 (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) (8) (Light/surge voltage suppressor) 4(A) port side : Blue (For rubber seal)
: Gray (For metal seal)
Triangle mark (Connector entry upward direction) 2(B) port side : Yellow

Plug-in
(8)
(DIN rail)
LOCK

B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A

70.6

128.8
115
FREE

(5.5)

96.7

Metal Base
(77.1)
79.5

44.2

12 B 12 B 12 B 12 B 12 B

5.5

Plug-in
8.8

3.9
(6)
Applicable connector:
(9.3)

(A, B port: ø12)


(17.9)
26 pins MIL type with strain relief
20.7 L2 1.5 4 x M5 mounting hole
(Conforming to MIL-C-83503)
(5.3) (L4) (Fitting for the type with P/E
(DIN rail mounting hole pitch: 12.5) ports on the U and/or D sides)

Manifold Exploded View


(L3)

Type 50, 51, 52


One-touch fitting
One-touch fitting (Station 1) (Station n) [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: ø6, ø1/4"
Applicable tube O.D.: ø12, ø1/2" : ø8, ø5/16"
: ø10, ø3/8"
18.8 : ø12
Note 1) These figures show the

2
“SS5Y7-10P2-05D-C8”.
Note 2) Refer to page 183 for 1 P 1 P

82.7
(75.4)

2 B2 B2 B2 B2 B
dimensions of external pilot,

56.6

Connector Connecting Base


48.6

silencer, elbow fittings and


14.2

3/5 E 3/5 E

11.1
8.7
35.2

31.6
4 A4 A4 A4 A4 A
slide locking manual override.
Note 3) Refer to page 188 for
dimensions of A or B port
top-ported type.
Note 4) Only connectors are different

(For DIN rail


(Pitch)
(10)
(21.7)
for 10PG, 10PH, 10J and

mounting)
(14.3)
39.5 20.5 P = 19
10G. L1 to L5 dimensions are
the same as 10P type.

10PJG (20 pins) 10PH (10 pins) 10G (20 pins)

Plug-in
For PC wiring LED Switch for locking a connector
Triangle mark
Triangle mark Power supply terminal Triangle mark

Manifold Exploded View


(
24 VDC
)

Type 10, 11, 12


+COM
–(Negative)
LOCK

LOCK

LOCK

+(Positive)
PCW type

PCW type

(M3 terminal screw)


FREE

FREE

FREE
65.6

Plug Assembly Part No.


One-touch Fittings/

Applicable connector: Applicable connector: Applicable connector:


20 pins MIL type with strain relief 10 pins MIL type with strain relief 20 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Manifold Options

L1 121.2 140.2 159.2 178.2 197.2 216.2 235.2 254.2 273.2 292.2 311.2 330.2 349.2 368.2 387.2 406.2 425.2 444.2 463.2 482.2 501.2 520.2 539.2
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 160.5 173 198 210.5 235.5 248 273 285.5 310.5 323 348 360.5 385.5 398 423 435.5 460.5 485.5 498 523 535.5 560.5 573
L4 150 162.5 187.5 200 225 237.5 262.5 275 300 312.5 337.5 350 375 387.5 412.5 425 450 475 487.5 512.5 525 550 562.5
L5 22.5 19.5 22.5 19 22 19 22 18.5 21.5 18.5 21.5 18 21 18 21 17.5 20.5 23.5 20.5 23.5 20 23 20

92
Plug-in Connector Connecting Base
Type 12
Top Ported D-sub Connector Flat Ribbon Cable PC Wiring

Series SY3000/5000/7000 How to Order Manifold

SS5Y 3 12 F 1 05 U RoHS
Refer to pages 186 to 188 for
dimensions of Type 12/Top ported type.        
 Series  Connector entry direction
3 SY3000 1: Upward 2: Lateral ∗ The connector entry direc-
5 SY5000 tion for connector type "FW"
7 SY7000 D-sub connector <IP67>
can not be rotated. If it is
 Connector type LOC
K
LOC
K
necessary to change, order
F: D-sub connector FW: D-sub connector P: Flat ribbon cable PG: Flat ribbon cable FRE
E
FRE
E
connector block assembly
<IP40> <IP67> (26 pins) (20 pins) (page 208) separately.
(25 pins) New (25 pins)
 Valve stations
LOC
K
LOC
K
LOC
K
F/FW: D-sub connector (25 pins) P: Flat ribbon cable (26 pins)
FRE
E
FRE
E
FRE
E
Symbol Stations Note Symbol Stations Note
02 2 stations 02 2 stations
Double wiring Note 1) Double wiring Note 1)
PH: Flat ribbon cable J: PC wiring (20 pins) G: PC wiring (20 pins) 12 12 stations 12 12 stations
with power
(10 pins) Yellow ink New supply terminal 02 2 stations Specified layout Note 2) 02 2 stations Specified layout Note 2)
Yellow ink (Available up to (Available up to
24 24 stations 24 solenoids) 24 24 stations 24 solenoids)

LOC LOC
PG: Flat ribbon cable (20 pins) PH: Flat ribbon cable (10 pins)
K K
FRE PC FRE
Symbol Stations Note Symbol Stations Note
W ty
02 2 stations 02 2 stations
E E
pe

Double wiring Note 1) Double wiring Note 1)


09 9 stations 04 4 stations
 P, E port entry Note)  For type “S”, supply/exhaust 02 2 stations Specified layout Note 2) 02 2 stations Specified layout Note 2)
U Note) U side (2 to 10 stations) block assembly with built-in (Available up to (Available up to
D Note) D side (2 to 10 stations) silencer, choose U or D for P 18 18 stations 18 solenoids) 08 8 stations 8 solenoids)
B Both sides (2 to 24 stations) port entry.
J/G: PC wiring (20 pins) Note 1) Double wiring: 2-position
single, double, 3-position and
How to Order Manifold Assembly Symbol Stations
02 2 stations
Note
4-position valves can be
Double wiring Note 1) used on all manifold stations.
Use of a 2-position single
08 8 stations
Example (SS5Y3-12F1-) 02 2 stations Specified layout Note 2)
solenoid will result in an
2-position double (24 VDC) unused control signal. If this
2-position single (24 VDC) (Available up to is not desired, order with a
SY3230-5U1-C6 (1 set)
SY3130-5U1-C6 (3 sets) 16 16 stations 16 solenoids) specified layout.
3-position closed Note 2) Specified layout: Indicate the wiring specifications on the manifold
center (24 VDC)
specification sheet. (Note that 2-position double, 3-position and 4-position
SY3330-5U1-C6 (1 set) valves cannot be used where single wiring has been specified.)
Note 3) This also includes the number of blanking plate assembly.

 SUP/EXH block assembly  Mounting


LOC
K Nil Internal pilot Nil Direct mounting
ide
FRE Us Internal pilot, D DIN rail mounting (With DIN rail)
E
S
Built-in silencer D0 DIN rail mounting (Without DIN rail)
s
n
tio
ta

R External pilot D3 For 3 stations Specify a longer


S

Manifold base
3

∗ For built-in silencer type, P and rail than the


2

(5 stations) e D24 For 24 stations standard length.


1

sid E ports are available on U and


SS5Y3-12F1-05D D D sides. 3/5(E) port is plugged. Note) Refer to page 247 for the fixation
The silencer exhaust port is
SS5Y3-12F1-05D ······ 1 set (Type 12 5-station manifold base part no.) located on the opposite side of of DIN rail mounting type
∗SY3130-5U1-C6 ········ 3 sets (2-position single part no.) P, E port entry. (Example: When manifold.
∗SY3230-5U1-C6 ········ 1 set (2-position double part no.) the P, E port entry is D side, the
∗SY3330-5U1-C6 ········ 1 set (3-position closed center part no.) silencer exhaust port is U side.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
 P, E port size (One-touch fittings)
Symbol SY3000 SY5000 SY7000
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order Nil ø8 ø10 ø12
from the 1st station as shown in the figure above.
If the arrangement becomes complicated, specify on a manifold N ø5/16" ø3/8" ø1/2"
specification sheet.
∗ For N, sizes are in inches.

93
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
            

Plug-in
Top ported

 Series  Pilot valve option  A, B port size


3 SY3000 Nil Standard (102 psi (0.7 MPa)) Thread piping
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Symbol Port size Applicable series
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa)) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000

Metal Base
 Type of actuation pressure type. 02 1/4 SY7000
1 Single One-touch fitting (Metric)
2
2-position
Double
 Coil type Symbol A, B port SY3000 SY5000 SY7000
3 Closed center Nil Standard
C2 ø2  — —
4 T With power saving circuit (Continuous duty type)

Plug-in
3-position Exhaust center C3 ø3.2  — —
5 Pressure center ∗ Be sure to select the power saving circuit type C4 ø4   —
A∗ 4-position N.C./N.C. when the valve is continuously energized for
C6 ø6   
long periods of time.
B∗ dual N.O./N.O. C8 ø8 —  
∗ Be careful of the energizing time when the
C∗ 3-port N.C./N.O. power saving circuit is selected. Refer to page C10 ø10 — — 
∗ Only rubber seal type is available for the 244 for details. C12 ø12 — —

Manifold Exploded View



4-position dual 3-port valve.

Type 50, 51, 52


One-touch fitting (Inch)
 Rated voltage Symbol A, B port SY3000 SY5000 SY7000
5 24 VDC N1 ø1/8"  — —
 Seal type 6 12 VDC N3 ø5/32"   —
0 Rubber seal ∗ Connector type "G" (PC wiring with power supply N7 ø1/4"   
1 Metal seal terminal) of the manifold type is only available in 24 VDC. N9 ø5/16" —  
N11 ø3/8" — — 
 Light/surge voltage suppressor

Connector Connecting Base


 Pilot type and common specification
Surge voltage Common
 Thread type
Nil Internal pilot Symbol With light Nil Rc
suppressor specification
R External pilot F G
Nil — —
R — Non-polar N NPT
U  T NPTF
 Back pressure check valve S — Positive ∗ Only Nil is available for M5.
(Built-in valve type)  common
Z 
Nil None NS — Negative

Plug-in
H Built-in NZ  common  Type of mounting screw
∗ Only rubber seal type. Manifold installed type is ∗ Only “Z” and “NZ” types are available for with the Nil Round head combination screw
available if the back pressure check valve is power saving circuit. B Hexagon socket head cap screw

Manifold Exploded View


required for a valve with metal seal. Refer to ∗ For connector type "G" (PC wiring with power Round head combination screw

Type 10, 11, 12


page 232 for Ordering Example. However, it is supply terminal) of the manifold type, select K (Falling-out-prevention type)
not recommended to use the built-in valve type non-polar or positive common. Hexagon socket head cap screw
and the manifold installed type at the same time H (Falling-out-prevention type)
because it will reduce the flow.  Manual override
∗ The built-in valve type back pressure check ∗ For “K” and “H”, the valve body cover has a
Nil: D: drop prevention construction to stop the
valve is not available for the 3-position type and
Non-locking Push-turn mounting screws from falling out when the valve
the SY7000.
push type locking is removed for maintenance etc.
slotted ∗ When ordering a valve individually, the base
type gasket is not included. Since the base gasket is
Plug Assembly Part No.

attached to the manifold, please order the base


One-touch Fittings/

gasket separately if it is needed for


maintenance service.
Refer to page 220 for part numbers of the base
E: F:
gasket and mounting screw.
Push-turn Slide locking
∗ "B" and "H" cannot be selected for the individual
locking lever type SUP/EXH spacer assembly or interface
type regulator.
Manifold Options

∗ Refer to page 14 for with safety slide locking Protective class


manual override. class III (Mark: )

94
Series SY3000/5000/7000
Electrical Wiring Specifications Cable Assembly
015 015
D-sub connector
AXT100-DS25- 030 (N) [IP40] SY30M-DS25- 030 (N) [IP67]
050 050
Nil: Metric Nil: Metric
If alignment is not specified,
N: Inch N: Inch
the internal wiring is double
1
14 2 wiring (connected to SOL. a
15 and SOL. b) regardless of Cable Cable
3 0.3 mm2 x 25 cores 0.3 mm2 x 25 cores
16 4 number of stations, valve
17 O.D. ø1.4 O.D. ø1.4
5 and option types.
18 6 Approx. ø10
19 7
20 8
21 Approx. ø8
9 Connector terminal no. Seal (Length)
22 10
23 015
11
24 12 Molded cover

L
25 13 2 x M2.6 x 0.45
or Seal (Length)

44
2 x 4 − 40 UNC 015
Connector JBZ-25S-3 Connector hood
Terminal no. Polarity made by J.S.T. Mfg.

L
SOL.a Co.,Ltd.
1 (−) (+) (2.4)
Station 1 SOL.b 55
14 (−) (+)
SOL.a Socket side 2 x M2.6 x 0.45
2 (−) (+) 14 25

(86.5)
Station 2 SOL.b or
15 (−) (+)
SOL.a Terminal no. 2 x 4 − 40 UNC
16

3 (−) (+)
Station 3 SOL.b
16 (−) (+)
SOL.a 1 13
4 (−) (+)

8.7
Station 4 SOL.b 47.04
17 (−) (+)
SOL.a
5 (−) (+)
Station 5 SOL.b
18 (−) (+) Connector
SOL.a
6 (−) (+) JBZ-25S-3 made by
Station 6 SOL.b
19 (−) (+) J.S.T. Mfg. Co.,Ltd.
SOL.a
7 (−) (+)
Station 7 SOL.b 14…………25 Socket side
20 (−) (+)
SOL.a
8 (−) (+)
Station 8 SOL.b

22
21 (−) (+) Terminal no.
SOL.a
9 (−) (+)
Station 9 SOL.b 1…………13
22 (−) (+) 47.04
SOL.a
10 (−) (+)
Station 10 SOL.b
23 (−) (+) D-sub connector cable assembly [IP40] D-sub connector cable assembly [IP67]
SOL.a
11 (−) (+)
Station 11 SOL.b Cable Cable
24 (−) (+) Assembly part no. Note Assembly part no. Note
SOL.a length (L) length (L)
12 (−) (+)
Station 12 SOL.b 1.5 m AXT100-DS25-015 1.5 m SY30M-DS25-015
25 (−) (+) Cable Cable
3m AXT100-DS25-030 0.3 mm2 x 25 cores 3m SY30M-DS25-030
0.3 mm2 x 25 cores
COM. 5m AXT100-DS25-050 5m SY30M-DS25-050
13 (+) (−) ∗ Be sure to use the connector cable assembly
∗ When using a standard commercial
Positive Negative connector, use a 25-pin type female in the table, to satisfy enclosure IP67.
common common connector conforming to MIL-C-24308. ∗ Cannot be used for movable wiring.
Note) When using a valve with no polarity, either positive ∗ Cannot be used for movable wiring.
common or negative common can be used. ∗ Lengths other than the above are also
available. Please contact SMC for details.

Electrical characteristics Connector Manufacturers’ Example


Specified Layout
Item Property • Fujitsu, Ltd.
(25 pins) Mixed wiring of single and Conductor resistance • Japan Aviation Electronics Industry, Ltd.
65 or less
double wiring can be specified /km, 68°F (20°C) • J.S.T. Mfg. Co., Ltd.
on the manifold specification Voltage limit
• Hirose Electric Co., Ltd.
V, 1 minute, AC 1000
1 sheet. The maximum number
14
15
2
of stations is determined Insulation resistance
3
M/km, 68°F (20°C) 5 or more
16
17
4 according to the number of
5
18 6 solenoids. The total number of Note) The minimum bending radius
19
20
7
solenoids should be 24 or less. of the D-sub connector cable
8
21 is 20 mm.
22
9 1 solenoid is required for
10
23
24
11 2-position single, and 2 D-sub connector cable assembly terminal numbers
12
25 13 solenoids for 2-position double,
Terminal
3-position and 4-position. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
no.
Brown

Brown
White
White

White
Orange

Orange

Orange
Yellow

Yellow

Yellow
Purple

Purple
Black

Black

COM. Lead wire


Gray

Gray

Gray
Blue

Blue
Pink

Pink

Pink
Red

Red

color
White

White

White
White

White

Dot
Black
Black

Black
Black

Black
None
None
None
None
None
None
None

None
None

None
Red
Red
Red

Red
Red

marking

95
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Electrical Wiring Specifications
Flat ribbon cable connector
If alignment is not specified, the internal wiring
is double wiring (connected to SOL. a and
26 25
24 23
SOL. b) regardless of number of stations,
22 21 valve and option types.

Sub-plate
20 19
18 17
16 15
14 13
12 11 Connector terminal no.

Plug-in
10 9
8 7
Triangle mark indicator position
6 5
4 3
2 1

P: Flat ribbon cable (26 pins) PG: Flat ribbon cable (20 pins) G: Flat ribbon cable (20 pins)
<Double wiring> <Double wiring> PC wiring (with power supply terminal)

Metal Base
Terminal no. Polarity Terminal no. Polarity Terminal no.
SOL.a 1 (−) (+) SOL.a 1 (−) (+) SOL.a
Station 1 SOL.b Station 1 SOL.b 20 19 20
2 (−) (+) 2 (−) (+) Station 1 SOL.b
SOL.a SOL.a 18
3 (−) (+) 3 (−) (+)
Station 2 SOL.b Station 2 SOL.b SOL.a 16
4 (−) (+) 4 (−) (+)
SOL.a SOL.a 18 17 Station 2 SOL.b
5 (−) (+) 5 (−) (+)

Plug-in
14
Station 3 SOL.b Station 3 SOL.b
6 (−) (+) 6 (−) (+) SOL.a
SOL.a SOL.a 12
7 (−) (+) 7 (−) (+) 16 15 Station 3
Station 4 SOL.b Station 4 SOL.b SOL.b 10
8 (−) (+) 8 (−) (+)
SOL.a 9 (−) (+) SOL.a 9 (−) (+) SOL.a 8
Station 5 SOL.b Station 5 SOL.b Station 4
10 (−) (+) 10 (−) (+) 14 13 SOL.b 6
SOL.a 11 (−) (+) SOL.a 11 (−) (+) SOL.a

Manifold Exploded View


Station 6 SOL.b Station 6 SOL.b 19
12 (−) (+) 12 (−) (+)
Station 5

Type 50, 51, 52


SOL.a SOL.a 12 11 SOL.b 17
13 (−) (+) 13 (−) (+)
Station 7 SOL.b Station 7 SOL.b SOL.a
14 (−) (+) 14 (−) (+) 15
SOL.a 15 (−) (+) SOL.a 15 (−) (+) Station 6 SOL.b 13
Station 8 SOL.b Station 8 SOL.b 10 9
16 (−) (+) 16 (−) (+)
SOL.a SOL.a SOL.a 11
17 (−) (+) 17 (−) (+)
Station 9 SOL.b Station 9 SOL.b Station 7 SOL.b
18 (−) (+) 18 (−) (+) 8 7 9
SOL.a 19 (−) (+) COM. SOL.a
Station 10 SOL.b 19 (+) (−) 7
20 (−) (+) COM. Station 8 SOL.b
SOL.a 20 (+) (−) 5
21 (−) (+) Positive Negative 6 5
Station 11 SOL.b

Connector Connecting Base


22 (−) (+) common common
SOL.a 23 (−) (+)
Station 12 SOL.b 4 3
24 (−) (+)
COM.
25 (+) (−)
COM. J: Flat ribbon cable (20 pins)
26 (+) (−) 2 1
Positive Negative PC wiring
common common <Double wiring> Triangle mark 3,4
Terminal no. Polarity
SOL.a 20 (−) (+)
Station 1 SOL.b

Plug-in
18 (−) (+)
SOL.a 1,2
16 (−) (+) 24 VDC − +
Station 2 SOL.b 14 (−)
PH: Flat ribbon cable (10 pins) (+)
SOL.a Power supply terminal
12 (−) (+)

Manifold Exploded View


<Double wiring> Station 3 SOL.b 10 (−) (+)

Type 10, 11, 12


Terminal no. Polarity SOL.a
8 (−) (+)
SOL.a Station 4 SOL.b
1 (−) (+) 6 (−) (+)
Station 1 SOL.b SOL.a Note 1) This circuits are for the specifications with up to 8
2 (−) (+) 19 (−) (+)
SOL.a Station 5 SOL.b stations of 2-position double, 3-position and
3 (−) (+) 17 (−) (+)
Station 2 SOL.b SOL.a 4-position dual 3 port valve. There should be
4 (−) (+) 15 (−) (+)
SOL.a Station 6 SOL.b wired in order 20→18→16→14 without skipping
5 (−) (+) 13 (−) (+)
Station 3 SOL.b SOL.a or leaving any connectors remaining.
6 (−) (+) 11 (−) (+)
SOL.a Station 7 SOL.b Note 2) For details on PC wiring system, refer to the
7 (−) (+) 9 (−) (+)
Station 4 SOL.b SOL.a WEB catalog or the Best Pneumatics No. 1.
8 (−) (+) 7 (−) (+)
Station 8 SOL.b
COM. 5 (−) (+)
Plug Assembly Part No.

9 (+) (−)
One-touch Fittings/

COM. 4 (−) (+)


10 (+) (−)
Positive Negative 3 (−) (+)
common common COM. 2 (+) (−)
COM. 1 (+) (−)
Positive Negative
common common
Note) When using a valve with no polarity,
Manifold Options

either positive common or negative Note 1) This circuits are for the specifications with up to 8 stations of
common can be used. 2-position double, 3-position and 4-position dual 3 port valve.
There should be wired in order 20→18→16→14 without
skipping or leaving any connectors remaining.
Note 2) For details on PC wiring system, refer to the WEB catalog or
the Best Pneumatics No. 1.

96
Series SY3000/5000/7000
Flat Ribbon Cable Assembly
10 1
AXT100-FC 20 - 2
26 3

6 Terminal no. 28AWG


Red

17.2 (10 pins)


30 (20 pins)
37.5 (26 pins)

1
26

25
(15.6)
L

Flat ribbon cable connector assembly


Cable Assembly part no. Connector Manufacturers’ Example
length (L) 26 pins 20 pins 10 pins
• Hirose Electric Co., Ltd.
1.5 m AXT100-FC26-1 AXT100-FC20-1 AXT100-FC10-1
• Sumitomo 3M Limited
3m AXT100-FC26-2 AXT100-FC20-2 AXT100-FC10-2 • Fujitsu, Ltd.
5m AXT100-FC26-3 AXT100-FC20-3 AXT100-FC10-3 • Japan Aviation Electronics Industry, Ltd.
• J.S.T. Mfg. Co., Ltd.
∗ When using a standard commercial connector, use a 26-pin, 20-pin or 10-pin
• Oki Electric Cable Co., Ltd.
type connector conforming to MIL-C-83503 with strain relief.
∗ Cannot be used for movable wiring.
∗ Lengths other than the above are also available. Please contact SMC for details.

Specified Layout

COM. COM.

26 25
24 23 COM. COM.
22 21
20 19 20 19 20 19
18 17 18 17 18 17
16 15 16 15 16 15
14 13 14 13 COM. COM. 14 13
12 11 12 11 12 11
10 9 10 9 10 9
10 9
8 7 8 7 8 7
8 7
6 5 6 5 6 5
6 5
4 3 4 3 4 3
4 3
2 1 2 1 2 1
2 1
COM. COM.
(P: 26 pins) (PG: 20 pins) (PH: 10 pins) (J,G: 20 pins PC wiring)

Mixed wiring of single and double wiring can be specified on the manifold specification. The maximum number of stations is determined according to the number of solenoids. The
total number of solenoids should be 24 or less for P, 18 or less for PG, 8 or less for PH, and 16 or less for J/G. 1 solenoid is required for 2-position single, and 2 solenoids for
2-position double, 3-position and 4-position.

97
98
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Type 10 Plug-in Connector Connecting Base
Side Ported RoHS
Terminal Block Box

Series SY3000/5000/7000
Type 11
Bottom Ported

How to Order Manifold

Refer to pages 184 (SY5000) and


SS5Y 3 10 T 05 U C6
185 (SY7000) for dimensions of
Type 11/Bottom ported type.

 Series  Valve stations  P, E port entry


3 SY3000 Symbol Stations Note U U side (2 to 10 stations)
5 SY5000 02 2 stations D D side (2 to 10 stations)
7 SY7000 Double wiring Note 1) B Both sides (2 to 20 stations)
10 10 stations
02 2 stations
Specified layout Note 2)
 Type (Available up to 20 solenoids)
10 Side ported 20 20 stations  SUP/EXH block assembly
11 Bottom ported∗ Note 1) Double wiring: 2-position single, double, 3-position and Nil Internal pilot
4-position valves can be used on all manifold stations. S Internal pilot, Built-in silencer
∗ The SY5000 manifold base is
Use of a 2-position single solenoid will result in an unused
used for the bottom ported of the
control signal. If this is not desired, order with a specified R External pilot
SY3000. When ordering, refer to ∗ 3/5(E) port is plugged for the built-in silencer type.
layout.
“Plug-in Mixed Mounting Type ∗ When the built-in silencer type is used, keep the
Note 2) Specified layout: Indicate the wiring specifications with the
Manifold” (from page 189). exhaust port from coming in direct contact with water
manifold specification sheet. (Note that 2-position double,
3-position and 4-position valves cannot be used where or other liquids.
single wiring has been specified.)
Note 3) This also includes the number of blanking plate assembly.

Refer to the page on the right for .


How to Order Manifold Assembly
 Mounting and Option
Example (SS5Y3-10T-) Option
2-position double (24 VDC) Symbol Mounting
Name plate Station number
2-position single (24 VDC) SY3200-5U1 (1 set) Nil — —
3-position closed Direct
SY3100-5U1 (3 sets) AA mounting
 
center (24 VDC)
BA  —
SY3300-5U1 (1 set)
D — —
DIN rail
A mounting
 
B  —
Note 1) Enter the number of stations inside  when it is
larger than the number of valve stations. (Refer
ide to “DIN Rail Option” below.)
Us
s Note 2) Only direct mounting is available for Type 11
on
ati (Bottom ported).
St
3 Note 3) Refer to page 247 for the fixation of DIN rail
2
1 mounting type manifold.
ide
Ds
Manifold base DIN Rail Option
(5 stations)
Nil Direct mounting
SS5Y3-10T-05D-C6
0 Without DIN rail (with bracket)
SS5Y3-10T-05D-C6 ···1 set (Type 10 5-station manifold base part no.) 3 For 3 stations
Specify a longer rail than the
∗SY3100-5U1 ···············3 sets (2-position single part no.) total length of specified stations.
∗SY3200-5U1 ···············1 set (2-position double part no.) 24 For 24 stations
∗SY3300-5U1 ···············1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order from
the 1st station as shown in the figure above. If the arrangement becomes
complicated, specify on a manifold specification sheet.
Note) When mixing top ported configurations, select from page 106.
In this case, use caution as there is also output on the A and B port on base side.
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side.

99
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
 A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)

Sub-plate
Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2  — — — — N1 ø1/8"  — — — —

Plug-in
C3 ø3.2  — — — — N3 ø5/32"   —  —

Straight
C4 ø4   —  — N7 ø1/4"     
Straight

C6 ø6      N9 ø5/16" —    
C8 ø8 —     N11 ø3/8" — —  — 
C10 ø10 — —  —  CM∗ Straight port, mixed sizes     
C12 ø12 — —  —  LN3 ø5/32"  — — — —
CM∗

Upward
Straight port, mixed sizes      LN7 ø1/4"   — — —

Metal Base
L4 ø4   — — — LN9 ø5/16" —  — — —
L6 ø6    — — LN11 ø3/8" — —  — —
Upward

Elbow Note)
L8 ø8 —   — — BN3 ø5/32"  — — — —

Downward
L10 ø10 — —  — — BN7 ø1/4"   — — —

Plug-in
L12 ø12 — —  — — BN9 ø5/16" —  — — —
Elbow Note)

B4 ø4   — — — BN11 ø3/8" — —  — —
Downward

B6 ø6    — — Elbow port, mixed sizes


LM∗ (Including upward and    — —
B8 ø8 —   — — downward piping)

Manifold Exploded View


B10 ø10 — —  — — P, E port size
ø5/16" ø3/8" ø1/2" ø3/8" ø1/2"

Type 50, 51, 52


B12 ø12 — —  — — (One-touch fittings)
Elbow port, mixed sizes
LM∗ (Including upward and    — —
downward piping)

P, E port size
ø8 ø10 ø12 ø10 ø12
(One-touch fittings)

Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 226 to 228).
∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.

Connector Connecting Base


∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting direction.

Plug-in
Manifold Exploded View
Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

Protective class
class III (Mark: )

100
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 0 0 5 1
          
Base mounted

 Series  Pilot valve option  Manual override


3 SY3000 Nil Standard (102 psi (0.7 MPa)) Nil: D:
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Non-locking Push-turn
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa)) push type locking
∗ Only metal seal type is available for the high slotted
pressure type. type

 Type of actuation
1
2-position
Single  Coil type E: F:
2 Double Nil Standard Push-turn Slide locking
3 Closed center T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust center ∗ Be sure to select the power saving circuit type lever
5 Pressure center when the valve is continuously energized for type
A∗ N.C./N.C. long periods of time.
4-position
B∗ dual 3-port N.O./N.O. ∗ Be careful of the energizing time when the
C∗ N.C./N.O. power saving circuit is selected. Refer to page
∗ Refer to page 14 for with the safety slide locking
244 for details.
∗ Only rubber seal type is available for the manual override.
4-position dual 3-port valve.
 Rated voltage
5 24 VDC  Type of mounting screw
 Seal type 6 12 VDC
Nil Round head combination screw
0 Rubber seal B Hexagon socket head cap screw
1 Metal seal Round head combination screw
K (Falling-out-prevention type)
 Light/surge voltage suppressor
and common specification Hexagon socket head cap screw
H (Falling-out-prevention type)
 Pilot type Symbol With light
Surge voltage Common
Nil Internal pilot suppressor specification ∗ For “K” and “H”, the valve body cover has a drop
R External pilot Nil — — prevention construction to stop the mounting screws
R — Non-polar from falling out when the valve is removed for
U  maintenance etc.
∗ When ordering a valve individually, the base gasket is
S — Positive
 Back pressure check valve (Built-in valve type) Z 
 common
not included. Since the base gasket is attached to the
manifold, please order the base gasket separately if it
Nil None NS — Negative is needed for maintenance service.
H Built-in NZ  common Refer to page 220 for part numbers of the base
∗ Only rubber seal type. Manifold installed type is ∗ Only “Z” and “NZ” types are available for with the gasket and mounting screw.
available if the back pressure check valve is power saving circuit. ∗ "B" and "H" cannot be selected for the individual
required for a valve with metal seal. Refer to SUP/EXH spacer assembly, interface regulator or
page 232 for Ordering Example. However, it is double check spacer assembly with residual pressure
not recommended to use the built-in valve type release valve.
and the manifold installed type at the same time
because it will reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type and
the SY7000.

Protective class
class III (Mark: )

101
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY3000 Connector Connecting Base Terminal Block Box

C2
U
C4, N3 (D)
SS5Y3-10T- Stations D - C3, N1

Sub-plate
B C6, N7

D side U side

Plug-in
(L5) L1
Manual override Note 2)

( )
DIN rail holding screw Push-turn locking slotted type:
DIN rail holding screw
(For DIN rail mounting) Press, then rotate it.
(For DIN rail mounting)

(8)
DIN rail 4(A) port side : Blue (For rubber seal)
(Light/surge : Gray (For metal seal)
voltage suppressor) 2(B) port side : Yellow

D side

U side

Metal Base
(5.5)
(8)
B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A
126

83

92.6

Plug-in
80

60.5
(40.9)
12 B 12 B 12 B 12 B 12 B

4.6

20.4
4.6
1.7
16

Manifold Exploded View


Type 50, 51, 52
)
1 4 x M4 mounting hole
(4.9)
C6: 3.6
N7: 7.4

2 x M5 mounting hole (Fitting for the type with P/E


ports on the U and/or D sides)
(

7.1 88.2 L2 1.5

(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

Connector Connecting Base


One-touch fitting One-touch fitting
[1(P), 3/5(E) port] [4(A), 2(B) port]
2 x G3/4 Applicable tube O.D.: ø8, ø5/16" Applicable tube O.D.: ø2
Conduit port : ø3.2, ø1/8"
(Station 1) --- (Station n) : ø4, ø5/32"
: ø6, ø1/4"

1 P 1 P

Plug-in
77.7

63.1
13.6
10.6

56.6
45.5

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

4 A4 A4 A4 A4 A
21.6
18

Manifold Exploded View


Type 10, 11, 12
13.2

(For DIN rail


(7.5)

mounting)

34.9
(11.8)

(Pitch)
107.1 15.5 P = 10.5 (17.8)

Note 1) These figures show the “SS5Y3-10T-05D-C6”.


Note 2) Refer to page 181 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 186 for dimensions of A or B port top-ported type.
Plug Assembly Part No.
One-touch Fittings/

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L1 164.3 174.8 185.3 195.8 206.3 216.8 227.3 237.8 248.3 258.8 269.3 279.8 290.3 300.8 311.3 321.8 332.3 342.8 353.3
Manifold Options

L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252
L3 198 198 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 335.5 335.5 348 360.5 373 385.5
L4 187.5 187.5 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 325 325 337.5 350 362.5 375
L5 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12 13 14 15 16

102
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base Terminal Block Box

U C4, N3
SS5Y5-10T- Stations D - C6, N7 (D)
B C8, N9

D side U side

DIN rail holding screw


(L5) L1 Manual override Note 2)
(For DIN rail mounting) DIN rail holding screw
(For DIN rail mounting)
( Push-turn locking slotted type:
Press, then rotate it. )
DIN rail (8) 4(A) port side : Blue (For rubber seal)
: Gray (For metal seal)
(Light/surge
2(B) port side : Yellow
voltage suppressor)
D side

U side

(5.5)
(8)
BA BA BA BA BA

(35)
14 A 14 A 14 A 14 A 14 A
126.4

97.5

113.4
80

81.2
(61.7)
5.5
12 B 12 B 12 B 12 B 12 B
16.4

10.9
1

4.7
(5.9)
(8.3)

2 x M5 mounting hole
4 x M5 mounting hole
7.1 87.7 L2 1.5
(Fitting for the type with P/E
(5.3) (L4) ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting
[1(P), 3/5(E) port] One-touch fitting
Applicable tube O.D.: ø10, ø3/8" [4(A), 2(B) port]
(Station 1) ----------- (Station n) Applicable tube O.D.: ø4, ø5/32"
2 x G3/4
: ø6, ø1/4"
Conduit port : ø8, ø5/16"

1 P 1 P
77.7

14.1

73.2
8.7

2 B2 B2 B2 B2 B
56.6
45.5

3/5 E 3/5 E
33.4

29.1

4 A4 A4 A4 A4 A
13.2

12.4

(For DIN rail


(7.5)

mounting)

34.9
(11.8)

(Pitch)
108.8 18 P = 16 (20.5)

Note 1) These figures show the “SS5Y5-10T-05D-C8”.


Note 2) Refer to page 182 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 187 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L1 181.3 197.3 213.3 229.3 245.3 261.3 277.3 293.3 309.3 325.3 341.3 357.3 373.3 389.3 405.3 421.3 437.3 453.3 469.3
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368
L3 210.5 223 248 260.5 273 285.5 310.5 323 335.5 360.5 373 385.5 398 423 435.5 448 460.5 485.5 498
L4 200 212.5 237.5 250 262.5 275 300 312.5 325 350 362.5 375 387.5 412.5 425 437.5 450 475 487.5
L5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14 12.5 17 15 13.5 11.5 16 14.5

103
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY7000 Connector Connecting Base Terminal Block Box

C6, N7
U
C10, N11 (D)
SS5Y7-10T- Stations D - C8, N9

Sub-plate
B C12

D side U side

(L5) Manual override Note 2)

Plug-in
L1
DIN rail holding screw DIN rail holding screw (
Push-turn locking slotted type:
Press, then rotate it. )
(8)
(For DIN rail mounting) (For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor) : Gray (For metal seal)
2(B) port side : Yellow

D side

U side
(8)
(DIN rail)

Metal Base
B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A
141.8
80

128.8
115
(5.5)

96.7

Plug-in
(77.1)
12 B 12 B 12 B 12 B 12 B

5.5
31.8

Manifold Exploded View


1

8.8
3.9
(6)

Type 50, 51, 52


(9.3)

2 x M5 mounting hole
(A, B port: ø12)
(17.9)

4 x M5 mounting hole
7.1 87.9 L2 1.5
(Fitting for the type with P/E
(5.3) (L4) ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

Connector Connecting Base


One-touch fitting One-touch fitting
[1(P), 3/5(E) port] [4(A), 2(B) port]
Applicable tube O.D.: ø12, ø1/2" Applicable tube O.D.: ø6, ø1/4"
(Station 1) (Station n) : ø8, ø5/16"
2 x G3/4 : ø10, ø3/8"
: ø12
Conduit port

Plug-in
1 P 1 P
82.7
77.7

2 B2 B2 B2 B2 B
56.6
45.5

3/5 E 3/5 E
11.1
8.7
35.2

31.6

4 A4 A4 A4 A4 A

Manifold Exploded View


Type 10, 11, 12
14.2
13.2

(For DIN rail


(10)

34.9 (Pitch) (21.7)


mounting)
(14.3)

113.8 20.5 P = 19

Note 1) These figures show the “SS5Y7-10T-05D-C10”.


Note 2) Refer to page 183 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Plug Assembly Part No.

Note 3) Refer to page 188 for dimensions of A or B port top-ported type.


One-touch Fittings/

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Manifold Options

L1 195.5 214.5 233.5 252.5 271.5 290.5 309.5 328.5 347.5 366.5 385.5 404.5 423.5 442.5 461.5 480.5 499.5 518.5 537.5
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436
L3 223 248 260.5 285.5 298 323 335.5 360.5 373 398 410.5 435.5 448 473 485.5 510.5 523 548 573
L4 212.5 237.5 250 275 287.5 312.5 325 350 362.5 387.5 400 425 437.5 462.5 475 500 512.5 537.5 562.5
L5 14 17 13.5 16.5 13.5 16.5 13 16 13 16 12.5 15.5 12.5 15.5 12 15 12 15 18

104
Plug-in Connector Connecting Base
Type 12 RoHS
Top Ported Terminal Block Box

Series SY3000/5000/7000
How to Order Manifold

SS5Y 3 12T 05 U
Refer to pages 186 to 188 for
dimensions of Type 12/Top ported type.      
 Series  Valve stations  SUP/EXH block assembly
3 SY3000 Symbol Stations Note Nil Internal pilot
5 SY5000 02 2 stations S Internal pilot, Built-in silencer
7 SY7000 Double wiring Note 1) R External pilot
10 10 stations ∗ For built-in silencer type, P and E ports are
02 2 stations available on U and D sides. 3/5(E) port is
Specified layout Note 2)
 P, E port entry (Available up to 20 solenoids)
plugged. The silencer exhaust port is located on
20 20 stations the opposite side of P, E port entry. (Example:
U Note) U side (2 to 10 stations) When the P, E port entry is D side, the silencer
D Note) D side (2 to 10 stations) Note 1) Double wiring: 2-position single, double, exhaust port is U side.)
3-position and 4-position valves can be ∗ When the built-in silencer type is used, keep the
B Both sides (2 to 20 stations)
used on all manifold stations. exhaust port from coming in direct contact with
Note) For type “S”, supply/exhaust block assembly Use of a 2-position single solenoid will result
with built-in silencer, choose U or D for P port water or other liquids.
in an unused control signal. If this is not
entry. desired, order with a specified layout.
Note 2) Specified layout: Indicate the wiring
specifications on the manifold specification
sheet. (Note that 2-position double,
3-position and 4-position valves cannot be  P, E port size
used where single wiring has been (One-touch fittings)
specified.)
Note 3) This also includes the number of blanking
Symbol SY3000 SY5000 SY7000
plate assembly. Nil ø8 ø10 ø12
N ø5/16" ø3/8" ø1/2"
∗ For N, sizes are in inches.
How to Order Manifold Assembly

Example (SS5Y3-12T-)
2-position double (24 VDC)
 Mounting
SY3230-5U1-C6 (1 set) Nil Direct mounting
2-position single (24 VDC) 3-position closed DIN rail mounting
SY3130-5U1-C6 (3 sets) center (24 VDC) D
(With DIN rail)
SY3330-5U1-C6 (1 set) DIN rail mounting
D0
(Without DIN rail)
D3 For 3 stations Specify a longer rail than
the standard length.
D20 For 20 stations
Note) Refer to page 247 for the fixation of DIN rail
ide
Us mounting type manifold.
s
n
tio
ta
S
3
2

ide
1

Ds
Manifold base
(5 stations)
SS5Y3-12T-05D
SS5Y3-12T-05D ············1 set (Type 12 5-station manifold base part no.)
∗SY3130-5U1-C6 ············3 sets (2-position single part no.)
∗SY3230-5U1-C6 ············1 set (2-position double part no.)
∗SY3330-5U1-C6 ············1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.

105
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
            

Plug-in
Top ported

 Series  Pilot valve option  A, B port size


3 SY3000 Nil Standard (102 psi (0.7 MPa)) Thread piping
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Symbol Port size Applicable series
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa)) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000

Metal Base
pressure type. 02
 Type of actuation 1/4 SY7000

1 Single One-touch fitting (Metric)


2
2-position
Double  Coil type Symbol A, B port SY3000 SY5000 SY7000
3 Closed center Nil Standard C2 ø2  — —

Plug-in
4 3-position Exhaust center T With power saving circuit (Continuous duty type) C3 ø3.2  — —
5 Pressure center ∗ Be sure to select the power saving circuit type C4 ø4   —
A∗ N.C./N.C. when the valve is continuously energized for C6 ø6   
4-position
B∗ dual 3-port
N.O./N.O. long periods of time. C8 ø8 —  
C∗ N.C./N.O. ∗ Be careful of the energizing time when the C10 ø10 — — 
power saving circuit is selected. Refer to page C12

Manifold Exploded View


∗ Only rubber seal type is available for the ø12 — — 
244 for details.

Type 50, 51, 52


4-position dual 3-port valve. One-touch fitting (Inch)
Symbol A, B port SY3000 SY5000 SY7000
 Rated voltage N1 ø1/8"  — —
 Seal type 5 24 VDC N3 ø5/32"   —
6 12 VDC N7 ø1/4"   
0 Rubber seal
1 Metal seal N9 ø5/16" —  
N11 ø3/8" — — 

Connector Connecting Base


 Light/surge voltage suppressor
 Pilot type and common specification
Surge voltage Common  Thread type
Nil Internal pilot Symbol With light
suppressor specification
R External pilot
Nil Rc
Nil — — F G
R — Non-polar N NPT
U  T NPTF
 Back pressure check valve S —

Positive ∗ Only Nil is available for M5.
(Built-in valve type) Z  common

Plug-in
Nil None NS — Negative
H NZ  common
Built-in
∗ Only “Z” and “NZ” types are available for with the
 Type of mounting screw
∗ Only rubber seal type. Manifold installed type is

Manifold Exploded View


available if the back pressure check valve is power saving circuit. Nil Round head combination screw

Type 10, 11, 12


required for a valve with metal seal. Refer to B Hexagon socket head cap screw
page 232 for Ordering Example. However, it is Round head combination screw
not recommended to use the built-in valve type
 Manual override K (Falling-out-prevention type)
and the manifold installed type at the same time D: Hexagon socket head cap screw
Nil: H (Falling-out-prevention type)
because it will reduce the flow. Non-locking Push-turn
∗ The built-in valve type back pressure check push type locking ∗ For “K” and “H”, the valve body cover has a drop
valve is not available for the 3-position type and slotted type prevention construction to stop the mounting
the SY7000. screws from falling out when the valve is
removed for maintenance etc.
Plug Assembly Part No.

∗ When ordering a valve individually, the base


One-touch Fittings/

gasket is not included. Since the base gasket is


attached to the manifold, please order the base
E: F: gasket separately if it is needed for maintenance
Push-turn Slide locking service.
locking lever type Refer to page 220 for part numbers of the base
type gasket and mounting screw.
∗ "B" and "H" cannot be selected for the individual
Manifold Options

SUP/EXH spacer assembly or interface


regulator.

∗ Refer to page 14 for with the safety slide locking


manual override. Protective class
class III (Mark: )
106
Series SY3000/5000/7000

Terminal Block Connection


Step 1. Removing the terminal block cover Step 2. The below diagram shows the terminal block wiring.
Loosen the 4 mounting screws (M4) to remove the All stations are provided with double wiring
terminal block cover. regardless of the mounted valves.
Connect each wire to the power supply side, according
Terminal block cover to the markings provided inside the terminal block.
Mounting screw (M4)
M3 screw

Gasket

m
6m
Electrical entry
2 x G3/4

Step 3. Mounting the terminal block cover


Securely tighten the screws to the torque shown in the
below table only after confirming that the gasket is
installed correctly.
Proper tightening torque • Applicable crimped terminal: 1.25-3S, 1.25Y-3, 1.25Y-3N, 1.25Y-3.5
0.52 to 0.89 lbf·ft (0.7 to 1.2N·m)
• Name plate: VVQ5000-N-T
• Drip-proof plug assembly (for G3/4): AXT100-B06A

Electrical Wiring Specifications (IP67 compatible)


Standard wiring Specified Layout
Terminal no. Polarity Mixed wiring of single and double wiring can be
SOL.a
1A (−) (+) specified on the manifold specification sheet. The
Station 1 SOL.b
1B (−) (+) maximum number of stations is determined
1A

SOL.a
1B
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM

2A (−) (+) according to the number of solenoids. The total


1B 2B 3B 4B 5B 6B 7B 8B 9B 10B

2A

Station 2
2B

SOL.b
(−) number of solenoids should be 20 or less. 1
3A

2B (+)
3B

SOL.a
4A

3A (−) (+) solenoid is required for 2-position single, and 2


4B

Station 3 SOL.b
5A

3B (−) (+) solenoids for 2-position double, 3-position and


5B

SOL.a
6A 7A

4A (−) (+) 4-position.


6B

Station 4 SOL.b
4B (−) (+)
7B
8A

SOL.a
8B

5A (−) (+)
9A 10A COM

Station 5 SOL.b
9B 10B

5B (−) (+)
SOL.a
6A (−) (+)
Station 6 SOL.b
6B (−) (+)
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM

SOL.a
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM

1B 2B 3B 4B 5B 6B 7B 8B 9B 10B

7A (−) (+)
Station 7 SOL.b
1B 2B 3B 4B 5B 6B 7B 8B 9B 10B

7B (−) (+)
SOL.a
8A (−) (+)
If alignment is not specified, the Station 8 SOL.b
8B (−) (+)
internal wiring is double wiring SOL.a
9A (−) (+)
(connected to SOL. a and SOL. b) Station 9 SOL.b
regardless of number of stations, 9B (−) (+)
SOL.a
valve and option types. 10A (−) (+)
Station 10 SOL.b
10B (−) (+)

Note) When using a valve with no COM. (+) (−)


polarity, either positive Positive Negative
common or negative common common
common can be used.

107
108
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Type 10 Plug-in Connector Connecting Base
Side Ported RoHS
Lead Wire
Type 11
Bottom Ported
Series SY3000/5000/7000
How to Order Manifold

Refer to pages 184 (SY5000) and


SS5Y 3 10 L1 1 05 U C6
185 (SY7000) for dimensions of
Type 11/Bottom ported type.

 Series  Number of cores  Valve stations


3 SY3000 (Lead wire) (L1) (L3)
5 SY5000 L1 34 cores Symbol Stations Note Symbol Stations Note
7 SY7000 L2 17 cores 02 2 stations 02 2 stations
L3 9 cores Double wiring Note 1) Double wiring Note 1)
16 16 stations 04 4 stations
 Type 02 2 stations Specified layout Note 2) 02 2 stations Specified layout Note 2)
 Lead wire length (Available up to (Available up to
10 Side ported
24 24 stations 32 solenoids) 08 8 stations 8 solenoids)
11 Bottom ported∗ 1 0.6 m
∗ The SY5000 manifold base is 2 1.5 m (L2)
used for the bottom ported of the 3 3m Symbol Stations Note
SY3000. When ordering, refer to 02 2 stations
“Plug-in Mixed Mounting Type Double wiring Note 1)
Manifold” (from page 189).
08 8 stations
02 2 stations Specified layout Note 2)
(Available up to
16 16 stations 16 solenoids)
Note 1) Double wiring: 2-position single, double, 3-position and 4-position
How to Order Manifold Assembly valves can be used on all manifold stations.
Use of a 2-position single solenoid will result in an unused control
signal. If this is not desired, order with a specified layout.
Note 2) Specified layout: Indicate the wiring specifications on the manifold
Example (SS5Y3-10L11-) specification sheet. (Note that 2-position double, 3-position and
2-position double (24 VDC) 4-position valves cannot be used where single wiring has been
SY3200-5U1 (1 set) specified.)
2-position single (24 VDC)
3-position closed Note 3) This also includes the number of blanking plate assembly.
SY3100-5U1 (3 sets)
center (24 VDC)
SY3300-5U1 (1 set)  P, E port entry
U U side (2 to 10 stations)
D D side (2 to 10 stations)
B Both sides (2 to 24 stations)

e
s
U sid  SUP/EXH block assembly
on
ati Nil Internal pilot
St
3 S Internal pilot, Built-in silencer
2
e
1 R External pilot
D sid
∗ 3/5(E) port is plugged for the built-in silencer type.
Manifold base ∗ When the built-in silencer type is used, keep the exhaust port from coming in
(5 stations) direct contact with water or other liquids.
SS5Y3-10L11-05D-C6
SS5Y3-10L11-05D-C6 ···1 set (Type 10 5-station manifold base part no.)
∗SY3100-5U1 ···················3 sets (2-position single part no.)
∗SY3200-5U1 ···················1 set (2-position double part no.)
∗SY3300-5U1 ···················1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order from
the 1st station as shown in the figure above. If the arrangement becomes
complicated, specify on a manifold specification sheet.
Note) When mixing top ported configurations, select from page 116.
In this case, use caution as there is also output on the A and B port on base side.
Specify on a manifold specification sheet if plugs are required on the A and B port
on base side.

109
Valve
 A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)

Sub-plate
Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2  — — — — N1 ø1/8"  — — — —

Plug-in
C3 ø3.2  — — — — N3 ø5/32"   —  —

Straight
C4 ø4   —  — N7 ø1/4"     
Straight

C6 ø6      N9 ø5/16" —    
C8 ø8 —     N11 ø3/8" — —  — 
C10 ø10 — —  —  CM∗ Straight port, mixed sizes     
C12 ø12 — —  —  LN3 ø5/32"  — — — —
CM∗

Upward
Straight port, mixed sizes      LN7 ø1/4"   — — —

Metal Base
L4 ø4   — — — LN9 ø5/16" —  — — —
L6 ø6    — — LN11 ø3/8" — —  — —
Upward

Elbow Note)
L8 ø8 —   — — BN3 ø5/32"  — — — —

Downward
L10 ø10 — —  — — BN7 ø1/4"   — — —

Plug-in
L12 ø12 — —  — — BN9 ø5/16" —  — — —
Elbow Note)

B4 ø4   — — — BN11 ø3/8" — —  — —
Downward

B6 ø6    — — Elbow port, mixed sizes


LM∗ (Including upward and    — —
B8 ø8 —   — — downward piping)

B10 ø10 — —  — — P, E port size

Manifold Exploded View


ø5/16" ø3/8" ø1/2" ø3/8" ø1/2"
B12 ø12 — —  — — (One-touch fittings)

Type 50, 51, 52


Elbow port, mixed sizes
LM∗ (Including upward and    — —
downward piping)

P, E port size
ø8 ø10 ø12 ø10 ø12
(One-touch fittings)
Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 226 to 228).
∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting direction.

Connector Connecting Base


 Mounting and Option
Option DIN Rail Option
Symbol Mounting
Name plate Station number Nil Direct mounting
Nil — — 0 Without DIN rail (with bracket)
Direct
AA mounting
  3 For 3 stations Specify a longer rail than the
BA — total length of specified
···

···

Plug-in
D — — 24 For 24 stations stations.
DIN rail
A mounting
 
B  —

Manifold Exploded View


Note 1) Enter the number of stations inside  when it is larger than the

Type 10, 11, 12


number of valve stations. (Refer to “DIN Rail Option” above.)
Note 2) Only direct mounting is available for Type 11 (Bottom ported).
Note 3) Refer to page 247 for the fixation of DIN rail mounting type manifold.

Plug Assembly Part No.


One-touch Fittings/
Manifold Options

110
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 0 0 5 1
          
Base mounted

 Series  Pilot valve option  Manual override


3 SY3000 Nil Standard (102 psi (0.7 MPa)) Nil: D:
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Non-locking Push-turn
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa)) push type locking
∗ Only metal seal type is available for the high slotted
pressure type. type

 Type of actuation
1 Single  Coil type
2-position E: F:
2 Double Nil Standard Push-turn Slide locking
3 Closed center T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust center ∗ Be sure to select the power saving circuit type lever
5 Pressure center when the valve is continuously energized for type
A∗ N.C./N.C. long periods of time.
4-position ∗ Be careful of the energizing time when the
B∗ dual 3-port
N.O./N.O.
power saving circuit is selected. Refer to page
C∗ N.C./N.O.
244 for details. ∗ Refer to page 14 for with the safety slide locking
∗ Only rubber seal is available for the 4-position manual override.
dual 3-port valve.
 Rated voltage
5 24 VDC  Type of mounting screw
 Seal type 6 12 VDC
Nil Round head combination screw
0 Rubber seal B Hexagon socket head cap screw
1 Metal seal Round head combination screw
 Light/surge voltage suppressor K (Falling-out-prevention type)
and common specification H Hexagon socket head cap screw
(Falling-out-prevention type)
 Pilot type Symbol With light
Surge voltage Common
suppressor specification ∗ For “K” and “H”, the valve body cover has a drop
Nil Internal pilot
prevention construction to stop the mounting
Nil — —
R External pilot screws from falling out when the valve is
R — Non-polar
removed for maintenance etc.
U 
∗ When ordering a valve individually, the base
S — Positive gasket is not included. Since the base gasket is

 Back pressure check valve Z  common attached to the manifold, please order the base
(Built-in valve type) NS — Negative gasket separately if it is needed for maintenance
Nil None NZ  common service.
Refer to page 220 for part numbers of the base
H Built-in ∗ Only “Z” and “NZ” types are available for with the
power saving circuit. gasket and mounting screw.
∗ Only rubber seal type. Manifold installed type is ∗ "B" and "H" cannot be selected for the individual
available if the back pressure check valve is SUP/EXH spacer assembly, interface regulator
required for a valve with metal seal. Refer to or double check spacer assembly with residual
page 232 for Ordering Example. However, it is pressure release valve.
not recommended to use the built-in valve type
and the manifold installed type at the same time
because it will reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type and
the SY7000.

Protective class
class III (Mark: )

111
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY3000 Connector Connecting Base Lead Wire

C2
1 U
SS5Y3-10L 2 - Stations D - C3,
C4, N3 (D)
N1

Sub-plate
3 B C6, N7
D side U side
Manual override Note 2)
(L5) L1
DIN rail holding screw (
Push-turn locking slotted type:
Press, then rotate it. )

Plug-in
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail (Light/surge : Gray (For metal seal)
2(B) port side : Yellow
voltage suppressor)

(5.5)
(8)
B A B A B A B A B A

(35)

92.6
14 A 14 A 14 A 14 A 14 A

83

Metal Base
67.8

60.5
(40.9)
4.6
12 B 12 B 12 B 12 B 12 B
17

Plug-in
4.6
1.7
)C6: 3.6
N7: 7.4
(4.9)
4 x M4 mounting hole

(
18 (Fitting for the type with P/E
ports on the U and/or D sides)
43 L2 1.5

Manifold Exploded View


(L4)

Type 50, 51, 52


18 (5.3)
(Lead wire length)
0.6 m, 1.5 m, 3 m

(DIN rail mounting hole pitch: 12.5)


(L3)

One-touch fitting
[4(A), 2(B) port]
One-touch fitting
Applicable tube O.D.: ø2
(Station 1) --- (Station n)

Connector Connecting Base


[1(P), 3/5(E) port] : ø3.2, ø1/8"
Applicable tube O.D.: ø8, ø5/16" : ø4, ø5/32"
: ø6, ø1/4"
1 P 1 P
13.6
10.6

63.1
56.6

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

4 A4 A4 A4 A4 A
21.6
18

Plug-in
(For DIN rail
(7.5)

mounting)

(Pitch)
(11.8)

54.8 15.5 P = 10.5 (17.8)

Manifold Exploded View


Note 1) These figures show the “SS5Y3-10L1-05D-C6”. Type 10, 11, 12
Note 2) Refer to page 181 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 186 for dimensions of A or B port top-ported type.
Plug Assembly Part No.
One-touch Fittings/

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 112 122.5 133 143.5 154 164.5 175 185.5 196 206.5 217 227.5 238 248.5 259 269.5 280 290.5 301 311.5 322 332.5 343
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
Manifold Options

L3 135.5 148 160.5 173 185.5 198 210.5 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 335.5 335.5 348 360.5 373
L4 125 137.5 150 162.5 175 187.5 200 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 325 325 337.5 350 362.5
L5 12 13 14 15 16 17 18 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12 13 14 15

112
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base Lead Wire

1 U C4, N3
SS5Y5-10L 2 - Stations D - C6, N7 (D)
3 B C8, N9
D side U side
Manual override Note 2)
(L5)
DIN rail holding screw
L1
(Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail (Light/surge : Gray (For metal seal)
voltage suppressor) 2(B) port side : Yellow

(5.5)
(8)
BA BA BA BA BA

(35)
14 A 14 A 14 A 14 A 14 A

97.5
113.4
64.4

81.2
(61.7)
5.5
12 B 12 B 12 B 12 B 12 B
24.2

10.9
4.7
(5.9)
(8.3)

4 x M5 mounting hole
18
(Fitting for the type with P/E
18
42.5 L2 1.5
ports on the U and/or D sides)
(Lead wire length)
0.6 m, 1.5 m, 3 m

(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting
[4(A), 2(B) port]
(Station 1) ----------- (Station n) Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
One-touch fitting : ø8, ø5/16"
[1(P), 3/5(E) port]
Applicable tube O.D.: ø10, ø3/8"
14.1

1 P 1 P
73.2

2 B2 B2 B2 B2 B
56.6
8.7

3/5 E 3/5 E
33.4

29.1

4 A4 A4 A4 A4 A
12.4

(For DIN rail


(7.5)

(Pitch)
mounting)
(11.8)

56.5 18 P = 16 (20.5)

Note 1) These figures show the “SS5Y5-10L1-05D-C8”.


Note 2) Refer to page 182 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 187 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 129 145 161 177 193 209 225 241 257 273 289 305 321 337 353 369 385 401 417 433 449 465 481
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 160.5 173 185.5 210.5 223 235.5 260.5 273 285.5 298 323 335.5 348 360.5 385.5 398 410.5 435.5 448 460.5 473 498 510.5
L4 150 162.5 175 200 212.5 225 250 262.5 275 287.5 312.5 325 337.5 350 375 387.5 400 425 437.5 450 462.5 487.5 500
L5 16 14 12.5 17 15 13.5 18 16 14.5 12.5 17 15.5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15

113
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY7000 Connector Connecting Base Lead Wire

C6, N7
1 U
SS5Y7-10L 2 - Stations D - C8,
C10, N11 (D)
N9

Sub-plate
3 B C12

D side U side

Manual override Note 2)

Plug-in
(L5) L1
DIN rail holding screw (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
(Light/surge voltage suppressor) : Gray (For metal seal)
2(B) port side: Yellow

(8) (DIN rail)

Metal Base
B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A
64.4

128.8
115
(5.5)

96.7

Plug-in
(77.1)
12 B 12 B 12 B 12 B 12 B

5.5
39.6
(Lead wire length)
0.6 m, 1.5 m, 3 m

Manifold Exploded View


8.8
3.9
(6)

Type 50, 51, 52


(9.3)

18 (A, B port: ø12)


(17.9)

4 x M5 mounting hole
42.7 L2 1.5
(Fitting for the type with P/E
18 (5.3) (L4) ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

Connector Connecting Base


(Station 1) (Station n)

One-touch fitting
[1(P), 3/5(E) port] 2
Applicable tube O.D.: ø12, ø1/2"
1 P 1 P
82.7
2 B2 B2 B2 B2 B
56.6

3/5 E 3/5 E
11.1

Plug-in
8.7
35.2

31.6

4 A4 A4 A4 A4 A
14.2

Manifold Exploded View


Type 10, 11, 12
(Pitch)
(For DIN rail

(21.7)
(10)

mounting)

61.5 20.5 P = 19
One-touch fitting
(14.3)

[4(A), 2(B) port]


Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
: ø10, ø3/8"
: ø12
Plug Assembly Part No.

Note 1) These figures show the “SS5Y7-10L1-05D-C10”.


One-touch Fittings/

Note 2) Refer to page 183 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 188 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 143.2 162.2 181.2 200.2 219.2 238.2 257.2 276.2 295.2 314.2 333.2 352.2 371.2 390.2 409.2 428.2 447.2 466.2 485.2 504.2 523.2 542.2 561.2
Manifold Options

L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 173 185.5 210.5 235.5 248 273 285.5 310.5 323 348 360.5 385.5 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5
L4 162.5 175 200 225 237.5 262.5 275 300 312.5 337.5 350 375 387.5 412.5 425 450 462.5 487.5 500 525 537.5 562.5 575
L5 15 11.5 14.5 17.5 14.5 17.5 14 17 14 17 13.5 16.5 13.5 16.5 13 16 13 16 12.5 15.5 12.5 15.5 12

114
Plug-in Connector Connecting Base
Type 12 Lead Wire
Top Ported
Series SY3000/5000/7000
RoHS
How to Order Manifold

SS5Y 3 12 L1 1 05 U
Refer to pages 186 to 188 for
dimensions of Type 12/Top        
ported type.

 Series  Valve stations


3 SY3000 (L1) (L3)
5 SY5000 Symbol Stations Note Symbol Stations Note
7 SY7000 02 2 stations 02 2 stations
Double wiring Note 1) Double wiring Note 1)
 Number of cores 16 16 stations 04 4 stations
(Lead wire)  Lead wire length 02 2 stations Specified layout Note 2) 02 2 stations Specified layout Note 2)
L1 34 cores 1 0.6 m (Available up to (Available up to
L2 17 cores 2 1.5 m 24 24 stations 32 solenoids) 08 8 stations 8 solenoids)
L3 9 cores 3 3m (L2)
Symbol Stations Note
 P, E port entry 02 2 stations
U Note) U side (2 to 10 stations) Double wiring Note 1)
D Note) D side (2 to 10 stations) 08 8 stations
B Both sides (2 to 24 stations) 02 2 stations Specified layout Note 2)
Note)  For type “S”, supply/exhaust block assembly (Available up to
with built-in silencer, choose U or D for P port 16 16 stations 16 solenoids)
entry. Note 1) Double wiring: 2-position single, double, 3-position and 4-position
valves can be used on all manifold stations.
How to Order Manifold Assembly Use of a 2-position single solenoid will result in an unused control
signal. If this is not desired, order with a specified layout.
Note 2) Specified layout: Indicate the wiring specifications on the manifold
specification sheet. (Note that 2-position double, 3-position and
Example (SS5Y3-12L11-) 4-position valves cannot be used where single wiring has been
specified.)
2-position double (24 VDC) Note 3) This also includes the number of blanking plate assembly.
SY3230-5U1-C6 (1 set)
2-position single (24 VDC)
3-position closed
 SUP/EXH block assembly
SY3130-5U1-C6 (3 sets) center (24 VDC) Nil Internal pilot
SY3330-5U1-C6 (1 set) S Internal pilot, Built-in silencer
R External pilot
∗ For built-in silencer type, P and E ports are available on U and D sides.
3/5(E) port is plugged. The silencer exhaust port is located on the opposite
side of P, E port entry. (Example: When the P, E port entry is D side, the
silencer exhaust port is U side.)
∗ When the built-in silencer type is used, keep the exhaust port from coming in
e direct contact with water or other liquids.
U sid
s
on
ati
St

1
2
3
 P, E port size (One-touch fittings)
e
D sid Symbol SY3000 SY5000 SY7000
Manifold base
(5 stations) Nil ø8 ø10 ø12
SS5Y3-12L11-05D
N ø5/16" ø3/8" ø1/2"
∗ For N, sizes are in inches.
SS5Y3-12L11-05D ···1 set (Type 12 5-station manifold base part no.)
∗SY3130-5U1-C6 ·······3 sets (2-position single part no.)
∗SY3230-5U1-C6 ·······1 set (2-position double part no.)  Mounting
∗SY3330-5U1-C6 ·······1 set (3-position closed center part no.) Nil Direct mounting
The asterisk denotes the symbol for assembly. D DIN rail mounting (With DIN rail)
Prefix it to the part numbers of the valve etc. D0 DIN rail mounting (Without DIN rail)
• The valve arrangement is numbered as the 1st station from the D side. D3 For 3 stations
Specify a longer rail than
···

···

• Under the manifold part number, state the valves to be mounted in order the standard length.
from the 1st station as shown in the figure above. If the arrangement D24 For 24 stations
becomes complicated, specify on a manifold specification sheet. Note) Refer to page 247 for the fixation of DIN rail mounting type manifold.

115
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
            

Plug-in
Top ported

 Series  Pilot valve option  A, B port size


3 SY3000 Nil Standard (102 psi (0.7 MPa)) Thread piping
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Symbol Port size Applicable series
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa)) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000

Metal Base
pressure type. 02 1/4 SY7000
 Type of actuation One-touch fitting (Metric)
1 Single  Coil type Symbol A, B port SY3000 SY5000 SY7000
2-position C2 ø2 — —
2 Double Nil Standard 

Plug-in
3 Closed center T With power saving circuit (Continuous duty type) C3 ø3.2  — —
4 3-position Exhaust center ∗ Be sure to select the power saving circuit type C4 ø4   —
5 Pressure center when the valve is continuously energized for C6 ø6   
A∗ N.C./N.C. long periods of time. C8 ø8 —  
4-position ∗ Be careful of the energizing time when the
B∗ dual 3-port
N.O./N.O. C10 ø10 — — 
power saving circuit is selected. Refer to page
C∗

Manifold Exploded View


N.C./N.O. C12 ø12 — — 
244 for details.

Type 50, 51, 52


∗ Only rubber seal type is available for the One-touch fitting (Inch)
4-position dual 3-port valve.  Rated voltage Symbol A, B port SY3000 SY5000 SY7000
5 24 VDC N1 ø1/8"  — —
6 12 VDC N3 ø5/32"   —
 Seal type N7 ø1/4"   
0 Rubber seal N9 ø5/16" —  
1 Metal seal N11 ø3/8" — — 
 Light/surge voltage suppressor

Connector Connecting Base


and common specification
Surge voltage Common
 Pilot type Symbol With light
suppressor specification  Thread type
Nil Internal pilot Nil — — Nil Rc
R External pilot R — Non-polar F G
U  N NPT
S — Positive T NPTF
 common
Z  ∗ Only Nil is available for M5.
 Back pressure check valve NS — Negative

Plug-in
(Built-in valve type) NZ  common
Nil None ∗ Only “Z” and “NZ” types are available for with the  Type of mounting screw
H Built-in power saving circuit.

Manifold Exploded View


Nil Round head combination screw
∗ Only rubber seal type. Manifold installed type is

Type 10, 11, 12


available if the back pressure check valve is B Hexagon socket head cap screw
required for a valve with metal seal. Refer to  Manual override K
Round head combination screw
(Falling-out-prevention type)
page 232 for Ordering Example. However, it is Nil: D:
not recommended to use the built-in valve type Hexagon socket head cap screw
Non-locking Push-turn H (Falling-out-prevention type)
and the manifold installed type at the same time push type locking slotted
because it will reduce the flow. type ∗ For “K” and “H”, the valve body cover has a drop
∗ The built-in valve type back pressure check prevention construction to stop the mounting
valve is not available for the 3-position type and screws from falling out when the valve is
the SY7000. removed for maintenance etc.
Plug Assembly Part No.

∗ When ordering a valve individually, the base


One-touch Fittings/

gasket is not included. Since the base gasket is


E: F: attached to the manifold, please order the base
Push-turn Slide locking gasket separately if it is needed for maintenance
locking lever type service.
type Refer to page 220 for part numbers of the base
gasket and mounting screw.
∗ "B" and "H" cannot be selected for the individual
Manifold Options

SUP/EXH spacer assembly or interface


regulator.

∗ Refer to page 14 for with the safety slide locking


manual override.
Protective class
class III (Mark: )
116
Series SY3000/5000/7000
Electrical Wiring Specifications
Lead wire Electrical characteristics
Item Property
If alignment is not specified, the internal Conductor resistance
34 cores Lead wire
wiring is double wiring (connected to SOL. Ω/km, 68°F (20°C)
143 or less
0.18 mm2 x 34 cores a and SOL. b) regardless of number of Voltage limit
stations, valve and option types. 2000
34 1 2
V, 1 minute, AC
33 11 3
32 26 12 4 Insulation resistance
25 17 13 10 or more
31 21 18 5 MΩ/km, 68°F (20°C)
30 24 20 19 14 6
29 23 15 7
Note) Cannot be used for movable wiring.
22 16
28 8 The minimum bending radius of the cable
27 10 9
Sheath O.D. is 55 mm.
Approx. ø8.8

Lead Printed mark


wire (Both sides)
Lead wire no. Polarity color Type Color
SOL.a
1 (−) (+) Red
Station 1 SOL.b Orange
2 (−) (+) Black
SOL.a
3 (−) (+) Light Red
Station 2 SOL.b gray
4 (−) (+) Black
SOL.a
5 (−) (+) Red
Station 3 SOL.b White
6 (−) (+) Black
SOL.a
7 (−) (+) Red
Station 4 SOL.b Yellow
8 (−) (+) Black
SOL.a
9 (−) (+) Red
Station 5 SOL.b Pink
10 (−) (+) Black
SOL.a
11 (−) (+) Red
Station 6 SOL.b Orange
12 (−) (+) Black
SOL.a
13 (−) (+) Light Red
Station 7 SOL.b
14 (−) (+) gray Black
SOL.a
15 (−) (+) Red
Station 8 SOL.b White
16 (−) (+) Black
SOL.a
17 (−) (+) Red
Station 9 SOL.b Yellow
18 (−) (+) Black
SOL.a
19 (−) (+) Red
Station 10 SOL.b Pink
20 (−) (+) Black
SOL.a
21 (−) (+) Red
Station 11 SOL.b Orange
22 (−) (+) Black
SOL.a
23 (−) (+) Light Red
Station 12 SOL.b
24 (−) (+) gray Black
SOL.a
25 (−) (+) Red
Station 13 SOL.b White
26 (−) (+) Black
SOL.a
27 (−) (+) Red
Station 14 SOL.b Yellow
28 (−) (+) Black
SOL.a
29 (−) (+) Red
Station 15 SOL.b Pink
30 (−) (+) Black
SOL.a 31 (−) (+) Red
Station 16 SOL.b Orange
32 (−) (+) Black
COM.
33 (+) (−) Light Red
COM. gray
34 (+) (−) Black
Positive Negative
common common
Note) For negative common specification, a valve for negative
common or a valve without polarity should be used.

Specified Layout
Mixed wiring of single and double wiring can be specified on the manifold
specification. The maximum number of stations is determined according
to the number of solenoids. The total number of solenoids should be 32
or less. 1 solenoid is required for 2-position single, and 2 solenoids for
2-position double, 3-position and 4-position.

117
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Electrical Wiring Specifications
Lead wire Electrical characteristics

Sub-plate
Item Property
Conductor resistance
Lead wire 143 or less
17 cores 9 cores Lead wire Ω/km, 68°F (20°C)
0.18 mm2 x 17 cores 0.18 mm2 x 9 cores
Voltage limit
2000
V, 1 minute, AC

Plug-in
1
17 2
1
16 13 8 9 3 9 2 Insulation resistance
10 or more
15 12 10 4
8 5 3 MΩ/km, 68°F (20°C)
11 7 4
14 5 6
7 6 Note) Cannot be used for movable wiring. Note) Cannot be used for movable wiring.
The minimum bending radius of the cable The minimum bending radius of the cable
is 45 mm. is 40 mm.
Sheath O.D. Sheath O.D.
Lead Printed mark Lead Printed mark
ø6.8 ø6.3
wire (Both sides) wire (Both sides)
Lead wire no. Polarity

Metal Base
Lead wire no. Polarity color Type Color color Type Color
SOL.a SOL.a
1 (−) (+) Red 1 (−) (+) Red
Station 1 SOL.b Orange Station 1 SOL.b Orange
2 (−) (+) Black 2 (−) (+) Black
SOL.a SOL.a
3 (−) (+) Light Red 3 (−) (+) Light Red
Station 2 SOL.b Station 2 SOL.b
4 (−) (+) gray 4 (−) (+) gray Black

Plug-in
Black
SOL.a SOL.a
5 (−) (+) Red 5 (−) (+) Red
Station 3 SOL.b White Station 3 SOL.b White
6 (−) (+) Black 6 (−) (+) Black
SOL.a SOL.a
7 (−) (+) Red 7 (−) (+) Red
Station 4 SOL.b Yellow Station 4 SOL.b Yellow
8 (−) (+) Black 8 (−) (+) Black
SOL.a COM.
9 (−) (+) Red 9 (+) (−) Pink Red

Manifold Exploded View


Station 5 SOL.b Pink

Type 50, 51, 52


10 (−) (+) Black Positive Negative
SOL.a common common
11 (−) (+) Red
Station 6 SOL.b Orange
12 (−) (+) Black
SOL.a Red
13 (−) (+) Light
Station 7 SOL.b gray
14 (−) (+) Black
SOL.a Red
15 (−) (+)
Station 8 SOL.b White
16 (−) (+) Black
COM. Yellow
17 (+) (−) Red

Connector Connecting Base


Positive Negative
common common

Note) For negative common specification, a valve for negative


common or a valve without polarity should be used.

Plug-in
Manifold Exploded View
Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

118
Type 10 Plug-in Connector Connecting Base
Side Ported
Circular Connector

Series SY3000/5000/7000
Type 11
Bottom Ported

RoHS
How to Order Manifold

Refer to pages 184 (SY5000) and


SS5Y 5 10 M 05 U C6
185 (SY7000) for dimensions of
Type 11/Bottom ported type.       
 Series  Valve stations  P, E port entry
3 SY3000 Symbol Stations Note U U side (2 to 10 stations)
5 SY5000 02 2 stations D D side (2 to 10 stations)
7 SY7000 Double wiring Note 1) B Both sides (2 to 24 stations)
···

···

12 12 stations
02 2 stations
 Type Specified layout Note 2)  SUP/EXH block assembly
···

···

(Available up to 24 solenoids)
10 Side ported 24 24 stations Nil Internal pilot
11 Bottom ported∗ Note 1) Double wiring: 2-position single, double, 3-position and S Internal pilot, Built-in silencer
∗ The SY5000 manifold base is 4-position valves can be used on all manifold stations. R External pilot
used for the bottom ported of the Use of a 2-position single solenoid will result in an ∗ 3/5(E) port is plugged for the built-in silencer type.
SY3000. When ordering, refer to unused control signal. If this is not desired, order with a ∗ When the built-in silencer type is used, keep the
“Plug-in Mixed Mounting Type specified layout. exhaust port from coming in direct contact with
Manifold” (from page 189). Note 2) Specified layout: Indicate the wiring specifications on the water or other liquids.
manifold specification sheet. (Note that 2-position
double, 3-position and 4-position valves cannot be used
where single wiring has been specified.)
Note 3) This also includes the number of blanking plate
Refer to the page on the right for .
assembly.

How to Order Manifold Assembly  Mounting and Option


Option
Symbol Mounting
Name plate Station number
Example (SS5Y3-10M-) Nil — —
2-position double (24 VDC) Direct
AA mounting
 
SY3200-5U1 (1 set) BA  —
2-position single (24 VDC)
3-position closed D — —
SY3100-5U1 (3 sets) center (24 VDC) DIN rail
A mounting
 
SY3300-5U1 (1 set)
B  —
Note 1) Enter the number of stations inside 
when it is larger than the number of valve
stations. (Refer to “DIN Rail Option”
below.)
Note 2) Only direct mounting is available for Type
ide 11 (Bottom ported).
Us Note 3) Refer to page 247 for the fixation of DIN
s
on rail mounting type manifold.
ati
St
3
2 DIN Rail Option
1
ide Nil Direct mounting
Ds
Manifold base 0 Without DIN rail (with bracket)
(5 stations) 3 For 3 stations
Specify a longer rail than the
SS5Y3-10M-05D-C6
···

···

total length of specified stations.


SS5Y3-10M-05D-C6 ···1 set (Type 10 5-station manifold base part no.) 24 For 24 stations
∗SY3100-5U1 ···············3 sets (2-position single part no.)
∗SY3200-5U1 ···············1 set (2-position double part no.)
∗SY3300-5U1 ···············1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.
Note) When mixing top ported configurations, select from page 126.
In this case, use caution as there is also output on the A and B port on base side.
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side.

119
Valve
 A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)

Sub-plate
Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2  — — — — N1 ø1/8"  — — — —

Plug-in
C3 ø3.2  — — — — N3 ø5/32"   —  —

Straight
C4 ø4   —  — N7 ø1/4"     
Straight

C6 ø6      N9 ø5/16" —    
C8 ø8 —     N11 ø3/8" — —  — 
C10 ø10 — —  —  CM∗ Straight port, mixed sizes     
C12 ø12 — —  —  LN3 ø5/32"  — — — —
CM∗

Upward
Straight port, mixed sizes      LN7 ø1/4"   — — —

Metal Base
L4 ø4   — — — LN9 ø5/16" —  — — —
L6 ø6    — — LN11 ø3/8" — —  — —
Upward

Elbow Note)
L8 ø8 —   — — BN3 ø5/32"  — — — —

Downward
L10 ø10 — —  — — BN7 ø1/4"   — — —

Plug-in
L12 ø12 — —  — — BN9 ø5/16" —  — — —
Elbow Note)

B4 ø4   — — — BN11 ø3/8" — —  — —
Downward

B6 ø6    — — Elbow port, mixed sizes


LM∗ (Including upward and    — —
B8 ø8 —   — — downward piping)

B10 ø10 — —  — — P, E port size

Manifold Exploded View


ø5/16" ø3/8" ø1/2" ø3/8" ø1/2"
B12 (One-touch fittings)

Type 50, 51, 52


ø12 — —  — —
Elbow port, mixed sizes
LM∗ (Including upward and    — —
downward piping)

P, E port size
ø8 ø10 ø12 ø10 ø12
(One-touch fittings)

Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 226 to 228).
∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.

Connector Connecting Base


∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting direction.

Plug-in
Manifold Exploded View
Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

Protective class
class III (Mark: )

120
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 0 0 5 1
          
Base mounted

 Series  Pilot valve option  Manual override


3 SY3000 Nil Standard (102 psi (0.7 MPa)) Nil: D:
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Non-locking Push-turn
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa)) push type locking
∗ Only metal seal type is available for the high slotted
pressure type. type

 Type of actuation
1 Single  Coil type
2-position E: F:
2 Double Nil Standard Push-turn Slide locking
3 Closed center T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust center ∗ Be sure to select the power saving circuit type lever
5 Pressure center when the valve is continuously energized for type
A∗ N.C./N.C. long periods of time.
4-position ∗ Be careful of the energizing time when the
B∗ dual 3-port
N.O./N.O.
power saving circuit is selected. Refer to page
C∗ N.C./N.O.
244 for details. ∗ Refer to page 14 for with the safety slide locking
∗ Only rubber seal type is available for the 4-position manual override.
dual 3-port valve.  Rated voltage
5 24 VDC
6 12 VDC  Type of mounting screw
 Seal type Nil Round head combination screw
0 Rubber seal B Hexagon socket head cap screw
1 Metal seal
 Light/surge voltage suppressor Round head combination screw
K (Falling-out-prevention type)
and common specification
Hexagon socket head cap screw
Symbol With light
Surge voltage Common H (Falling-out-prevention type)
 Pilot type suppressor specification
Nil — — ∗ For “K” and “H”, the valve body cover has a drop
Nil Internal pilot prevention construction to stop the mounting
R External pilot R — Non-polar
screws from falling out when the valve is
U  removed for maintenance etc.
S — Positive ∗ When ordering a valve individually, the base
 common
Z  gasket is not included. Since the base gasket is
 Back pressure check valve NS — Negative attached to the manifold, please order the base
(Built-in valve type) NZ  common gasket separately if it is needed for maintenance
service.
Nil None ∗ Only “Z” and “NZ” types are available for with the Refer to page 220 for part numbers of the base
H Built-in power saving circuit. gasket and mounting screw.
∗ Only rubber seal type. Manifold installed type is ∗ "B" and "H" cannot be selected for the individual
available if the back pressure check valve is SUP/EXH spacer assembly, interface regulator
required for a valve with metal seal. Refer to or double check spacer assembly with residual
page 232 for Ordering Example. However, it is pressure release valve.
not recommended to use the built-in valve type
and the manifold installed type at the same time
because it will reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type and
the SY7000.

Protective class
class III (Mark: )

121
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY3000 Connector Connecting Base Circular Connector

C2
U
C4, N3 (D)
SS5Y3-10M- Stations D - C3, N1

Sub-plate
B C6, N7
D side U side
(L5) L1 Manual override Note 2)

DIN rail holding screw (


Push-turn locking slotted type:
)

Plug-in
Press, then rotate it.
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail (Light/surge : Gray (For metal seal)
voltage suppressor) 2(B) port side : Yellow

(5.5)
(8)
B A B A B A B A B A

(35)

92.6
14 A 14 A 14 A 14 A 14 A

Metal Base
83
67.8

60.5
(40.9)
4.6
12 B 12 B 12 B 12 B 12 B

Plug-in
21.9

1.7

4.6
)
(4.9)

C6: 3.6
N7: 7.4
4 x M4 mounting hole
18
18 ( (Fitting for the type with P/E ports on the U and/or D sides)

43 L2 1.5

Manifold Exploded View


(5.3) (L4)

Type 50, 51, 52


(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] (Station 1) --- (Station n) Applicable tube O.D.: ø2
Applicable tube O.D.: ø8, ø5/16" : ø3.2, ø1/8"
: ø4, ø5/32"

Connector Connecting Base


Circular connector cable assembly : ø6, ø1/4"
1 P 1 P
AXT100-MC26-015: 1.5 m
AXT100-MC26-030: 3 m
63.1
13.6
10.6

56.6
AXT100-MC26-050: 5 m 3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

4 A4 A4 A4 A4 A
21.6
18

(For DIN rail

Circular connector (26 pins)


(7.5)

mounting)

(Pitch)
(11.8)

Plug-in
made by CONINVERS GmbH 54.8 15.5 (17.8)
P = 10.5

Manifold Exploded View


Type 10, 11, 12
Note 1) These figures show the “SS5Y3-10M-05D-C6”.
Note 2) Refer to page 181 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 186 for dimensions of A or B port top-ported type.

Plug Assembly Part No.


One-touch Fittings/

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Manifold Options

L1 112 122.5 133 143.5 154 164.5 175 185.5 196 206.5 217 227.5 238 248.5 259 269.5 280 290.5 301 311.5 322 332.5 343
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 135.5 148 160.5 173 185.5 198 210.5 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 335.5 335.5 348 360.5 373
L4 125 137.5 150 162.5 175 187.5 200 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 325 325 337.5 350 362.5
L5 12 13 14 15 16 17 18 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12 13 14 15

122
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base Circular Connector

U C4, N3
SS5Y5-10M- Stations D - C6, N7 (D)
B C8, N9 D side U side
Manual override Note 2)
(L5)
DIN rail holding screw
L1
(
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail (Light/surge voltage suppressor) : Gray (For metal seal)
2(B) port side : Yellow

(5.5)
(8)
BA BA BA BA BA

(35)
14 A 14 A 14 A 14 A 14 A

97.5
113.4
64.4

81.2
61.7
5.5
12 B 12 B 12 B 12 B 12 B
24.2

10.9
4.7
18
(5.9)
(8.3)

18 4 x M5 mounting hole
42.5 L2 1.5 (Fitting for the type with P/E
ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
Circular connector cable assembly (L3)
AXT100-MC26-015: 1.5 m
AXT100-MC26-030: 3 m
AXT100-MC26-050: 5 m
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
(Station 1)----------- (Station n)
: ø6, ø1/4"
One-touch fitting : ø8, ø5/16"
[1(P), 3/5(E) port]
Applicable tube O.D.: ø10, ø3/8"

1 P 1 P
14.1

73.2

2 B2 B2 B2 B2 B
56.6
12.4

8.7

3/5 E 3/5 E
33.4

29.1

4 A4 A4 A4 A4 A
(For DIN rail
mounting)
(7.5)

Circular connector (26 pins) (Pitch)


(11.8)

made by CONINVERS GmbH 56.5 18 P = 16 (20.5)

Note 1) These figures show the “SS5Y5-10M-05D-C8”.


Note 2) Refer to page 182 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 187 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 129 145 161 177 193 209 225 241 257 273 289 305 321 337 353 369 385 401 417 433 449 465 481
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 160.5 173 185.5 210.5 223 235.5 260.5 273 285.5 298 323 335.5 348 360.5 385.5 398 410.5 435.5 448 460.5 473 498 510.5
L4 150 162.5 175 200 212.5 225 250 262.5 275 287.5 312.5 325 337.5 350 375 387.5 400 425 437.5 450 462.5 487.5 500
L5 16 14 12.5 17 15 13.5 18 16 14.5 12.5 17 15.5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15

123
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY7000 Connector Connecting Base Circular Connector

C6, N7
U
C10, N11 (D)
SS5Y7-10M- Stations D - C8, N9

Sub-plate
B C12

D side U side

Manual override Note 2)

Plug-in
(L5) L1
DIN rail holding screw (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
: Gray (For metal seal)
(Light/surge voltage suppressor) 2(B) port side: Yellow

(8) (DIN rail)

Metal Base
B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A
64.4

128.8
115
(5.5)

96.7

Plug-in
(77.1)
12 B 12 B 12 B 12 B 12 B

5.5
39.6

Manifold Exploded View


8.8
3.9
18
(6)

Type 50, 51, 52


(9.3)

(A, B port: ø12)


(17.9)

18 4 x M5 mounting hole
42.7 L2 1.5 (Fitting for the type with P/E ports
(5.3) (L4) on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

Connector Connecting Base


One-touch fitting
Circular connector cable assembly
[4(A), 2(B) port]
AXT100-MC26-015: 1.5 m
Applicable tube O.D.: ø6, ø1/4"
AXT100-MC26-030: 3 m (Station 1) (Station n)
: ø8, ø5/16"
AXT100-MC26-050: 5 m
: ø10, ø3/8"
: ø12
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: ø12, ø1/2"
2

Plug-in
1 P 1 P
82.7

2 B2 B2 B2 B2 B
56.6

3/5 E 3/5 E
11.1
8.7
35.2

31.6

Manifold Exploded View


4 A4 A4 A4 A4 A

Type 10, 11, 12


14.2

(Pitch)
(For DIN rail

(21.7)
(10)

Circular connector (26 pins)


mounting)

61.5 20.5 P = 19
Made by CONINVERS GmbH
(14.3)

Note 1) These figures show the “SS5Y7-10M-05D-C10”.


Plug Assembly Part No.

Note 2) Refer to page 183 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
One-touch Fittings/

Note 3) Refer to page 188 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 143.2 162.2 181.2 200.2 219.2 238.2 257.2 276.2 295.2 314.2 333.2 352.2 371.2 390.2 409.2 428.2 447.2 466.2 485.2 504.2 523.2 542.2 561.2
Manifold Options

L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 173 185.5 210.5 235.5 248 273 285.5 310.5 323 348 360.5 385.5 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5
L4 162.5 175 200 225 237.5 262.5 275 300 312.5 337.5 350 375 387.5 412.5 425 450 462.5 487.5 500 525 537.5 562.5 575
L5 15 11.5 14.5 17.5 14.5 17.5 14 17 14 17 13.5 16.5 13.5 16.5 13 16 13 16 12.5 15.5 12.5 15.5 12

124
Plug-in Connector Connecting Base
Circular Connector
Type 12
Top Ported
Series SY3000/5000/7000
RoHS
How to Order Manifold

SS5Y 3 12M 05 U
Refer to pages 186 to 188 for
dimensions of Type 12/Top
ported type.
     
 Series  Valve stations  P, E port entry
3 SY3000 Symbol Stations Note U Note) U side (2 to 10 stations)
5 SY5000 02 2 stations D Note) D side (2 to 10 stations)
7 SY7000 Double wiring Note 1) B Both sides (2 to 24 stations)
···

···

12 12 stations Note) For type “S”, supply/exhaust block


02 2 stations assembly with built-in silencer, choose U or
Specified layout Note 2) D for P port entry.
···

···

(Available up to 24 solenoids)
24 24 stations
Note 1) Double wiring: 2-position single, double,
3-position and 4-position valves can be used
on all manifold stations.  SUP/EXH block assembly
Use of a 2-position single solenoid will result
in an unused control signal. If this is not Nil Internal pilot
desired, order with a specified layout. S Internal pilot, Built-in silencer
Note 2) Specified layout: Indicate the wiring R External pilot
specifications on the manifold specification ∗ For built-in silencer type, P and E ports are
sheet. (Note that 2-position double, 3-position available on U and D sides. 3/5(E) port is
and 4-position valves cannot be used where plugged. The silencer exhaust port is located on
single wiring has been specified.) the opposite side of P, E port entry. (Example:
Note 3) This also includes the number of blanking When the P, E port entry is D side, the silencer
plate assembly. exhaust port is U side.)
∗ When the built-in silencer type is used, keep the
exhaust port from coming in direct contact with
How to Order Manifold Assembly water or other liquids.

Example (SS5Y3-12M-)
2-position single (24 VDC)
2-position double (24 VDC)
SY3230-5U1-C6 (1 set)
 P, E port size (One-touch fittings)
SY3130-5U1-C6 (3 sets) Symbol SY3000 SY5000 SY7000
3-position closed
center (24 VDC)
Nil ø8 ø10 ø12
SY3330-5U1-C6 (1 set)
N ø5/16" ø3/8" ø1/2"
∗ For N, sizes are in inches.

Us
ide  Mounting
s
on Nil Direct mounting
ati
St
3 DIN rail mounting
2 D (With DIN rail)
1
e
sid DIN rail mounting
D D0 (Without DIN rail)
Manifold base (5 stations)
D3 For 3 stations
SS5Y3-12M-05D Specify a longer rail than
···

···

the standard length.


D24 For 24 stations
SS5Y3-12M-05D ········1 set (Type 12 5-station manifold base part no.)
Note) Refer to page 247 for the fixation of DIN rail
∗SY3130-5U1-C6 ········3 sets (2-position single part no.)
mounting type manifold.
∗SY3230-5U1-C6 ········1 set (2-position double part no.)
∗SY3330-5U1-C6 ········1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.

125
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
            

Plug-in
Top ported

 Series  Pilot valve option  A, B port size


3 SY3000 Nil Standard (102 psi (0.7 MPa)) Thread piping
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Symbol Port size Applicable series
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa)) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000

Metal Base
pressure type. 02 1/4 SY7000
 Type of actuation One-touch fitting (Metric)
1 Single  Coil type Symbol A, B port SY3000 SY5000 SY7000
2-position C2 ø2 — —
2 Double Nil Standard 

Plug-in
3 Closed center T With power saving circuit (Continuous duty type) C3 ø3.2  — —
4 3-position Exhaust center ∗ Be sure to select the power saving circuit type C4 ø4   —
5 Pressure center when the valve is continuously energized for C6 ø6   
A∗ N.C./N.C. long periods of time. C8 ø8 —  
4-position
B∗ dual 3-port N.O./N.O. ∗ Be careful of the energizing time when the C10 ø10 — — 
power saving circuit is selected. Refer to page
C∗ C12

Manifold Exploded View


N.C./N.O. ø12 — — 
244 for details.

Type 50, 51, 52


∗ Only rubber seal is available for the One-touch fitting (Inch)
4-position dual 3-port valve.  Rated voltage Symbol A, B port SY3000 SY5000 SY7000
5 24 VDC N1 ø1/8"  — —
6 12 VDC N3 ø5/32"   —
 Seal type N7 ø1/4"   
0 Rubber seal
N9 ø5/16" —  
1 N11 ø3/8" — — 
Metal seal  Light/surge voltage suppressor

Connector Connecting Base


and common specification
Surge voltage Common
 Pilot type Symbol With light
suppressor specification  Thread type
Nil — — Nil Rc
Nil Internal pilot
R — Non-polar F G
R External pilot
U  N NPT
S — Positive T NPTF
 common
Z  ∗ Only Nil is available for M5.
 Back pressure check valve NS — Negative

Plug-in
(Built-in valve type) NZ  common
Nil None ∗ Only “Z” and “NZ” types are available for with  Type of mounting screw
H Built-in the power saving circuit.

Manifold Exploded View


Nil Round head combination screw
∗ Only rubber seal type. Manifold installed type is

Type 10, 11, 12


available if the back pressure check valve is
B Hexagon socket head cap screw
required for a valve with metal seal. Refer to
 Manual override K
Round head combination screw
(Falling-out-prevention type)
page 232 for Ordering Example. However, it is Nil: D:
not recommended to use the built-in valve type Hexagon socket head cap screw
Non-locking Push-turn H (Falling-out-prevention type)
and the manifold installed type at the same time push type locking
because it will reduce the flow. slotted ∗ For “K” and “H”, the valve body cover has a drop
∗ The built-in valve type back pressure check type prevention construction to stop the mounting
valve is not available for the 3-position type and screws from falling out when the valve is
the SY7000. removed for maintenance etc.
Plug Assembly Part No.
One-touch Fittings/

∗ When ordering a valve individually, the base


gasket is not included. Since the base gasket is
E: F: attached to the manifold, please order the base
Push-turn Slide locking gasket separately if it is needed for maintenance
locking type service.
lever Refer to page 220 for part numbers of the base
type gasket and mounting screw.
Manifold Options

∗ "B" and "H" cannot be selected for the individual


SUP/EXH spacer assembly or interface
regulator.
∗ Refer to page 14 for with the safety slide locking
manual override. Protective class
class III (Mark: )

126
Series SY3000/5000/7000

Electrical Wiring Specifications Cable Assembly


015
Circular connector
AXT100-MC26- 030
If alignment is not specified, the 050
internal wiring is double wiring Cable
!5 q (connected to SOL. a and SOL. b) 0.3 mm2 x 26 cores
!4 !6 w
regardless of number of stations, O.D. ø1.4 Lead wire color for circular
!3 @4 !7 e
valve and option types. connector cable assembly
!2 @3 @5 !8 r
Approx. ø10 by terminal number
!1 @2 @6 !9 t Lead
Terminal Dot
!0 @1 @0 y Seal (Length) no.
wire
color marking
o i u
015 1
2
3
Black
Brown
Red
None
None
None
4 Orange None
Terminal no. Polarity
5 Yellow None
SOL.a
1 (−) (+) 6 Pink None
Station 1 SOL.b
2 (−) (+) 7 Blue None
SOL.a
3 (−) (+) 8 Purple White

L
Station 2 SOL.b
4 (−) (+) 9 Gray Black
SOL.a
5 (−) (+) 10 White Black
Station 3 SOL.b
6 (−) (+) 11 White Red

60
SOL.a
7 (−) (+) 12 Yellow Red
Station 4 SOL.b
8 (−) (+) 13 Orange Red
SOL.a Plug
9 (−) (+) 14 Yellow Black
Station 5 SOL.b
10 (−) (+) 15 Pink Black
SOL.a
11 (−) (+) 16 Blue White
Station 6 SOL.b
12 (−) (+) 17 Purple None
SOL.a
13 (−) (+) 18 Gray None
Station 7 SOL.b
14 (−) (+) 19 Orange Black
SOL.a ø30
15 (−) (+) 20 Red White
Station 8 SOL.b
16 (−) (+) 21 Brown White
SOL.a 15 1
17 (−) (+) 14 16 2 Terminal no. 22 Pink Red
Station 9 SOL.b 24 17
18 (−) (+) 13 3 23 Gray Red
SOL.a 25
19 (−) (+) 23 18
Station 10 12 4 24 Black White
SOL.b
20 (−) (+) 22 26 19 25 White None
SOL.a 11 21 20 5
21 (−) (+) 26 White None
Station 11 SOL.b 10 6
22 (−) (+) M27 female
SOL.a 9 8 7
23 (−) (+) thread
Station 12 SOL.b Electrical characteristics
24 (−) (+) Item Property
COM.
25 (+) (−) Conductor
COM. 65 or
26 (+) (−) resistance
less
Ω/km, 68°F (20°C)
Positive Negative
Voltage limit
common common 1000
V, 1 minute, AC
Circular connector cable assembly
Insulation
Cable Assembly part no. 5 or
resistance
length (L) 26 pins more
MΩ/km, 68°F (20°C)
Note) When using a valve with no polarity, either positive common or 1.5 m AXT100-MC26-015
negative common can be used. Note) The minimum bending
3m AXT100-MC26-030 radius of the circular
5m AXT100-MC26-050 connector cable is 20 mm.
∗ Cannot be used for movable wiring.
∗ Lengths other than the above is also
Specified Layout available. Please contact SMC for details.
Mixed wiring of single and double wiring can be specified on the manifold
specification sheet. The maximum number of stations is determined
according to the number of solenoids. The total number of solenoids
should be 24 or less. 1 solenoid is required for 2-position single, and 2
solenoids for 2-position double, 3-position and 4-position.

127
128
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Type 10 Plug-in Connector Connecting Base
Side Ported RoHS
EX500

Series SY3000/5000/7000
Type 11
Bottom Ported

How to Order Manifold

Refer to pages 184 (SY5000) and


SS5Y 3 10 S A2 05 U C6
185 (SY7000) for dimensions of
Type 11/Bottom ported type.        
 Series  SI unit  Valve stations
3 SY3000 0 Without SI unit Symbol Stations Note
5 SY5000 DeviceNet™/PROFIBUS DP/ 02 2 stations
7 SY7000 A2 EtherNet/IP™ Double wiring Note 1)

···

···
(Positive common) 08 8 stations
DeviceNet™/PROFIBUS DP/ 02 2 stations
 Type A2N EtherNet/IP™
Specified layout Note 2)

···

···
(Available up to 16 solenoids)
10 Side ported (Negative common) 16 16 stations
11 Bottom ported∗ Note) Ensure a match with the common Note 1) Double wiring: 2-position single, double,
∗ The SY5000 manifold base is used for the specification of the valve to be used. 3-position and 4-position valves can be
bottom ported of the SY3000. When ordering, used on all manifold stations.
refer to “Plug-in Mixed Mounting Type Manifold” Use of a 2-position single solenoid will
(from page 189). result in an unused control signal. If this is
not desired, order with a specified layout.
Note 2) Specified layout: Indicate the wiring
specifications on the manifold specification
sheet. (Note that 2-position double,
3-position and 4-position valves cannot be
used where single wiring has been
specified.)
Note 3) This also includes the number of blanking
How to Order Manifold Assembly plate assembly.
Note 4) For the product without the SI unit (S0),
note the maximum number of solenoids of
Example (SS5Y3-10SA2-) the SI unit that will be mounted. If the
2-position double (24 VDC) layout is specified, indicate it on the
2-position single (24 VDC) SY3200-5U1 (1 set) manifold specification sheet.
SY3100-5U1 (3 sets)
3-position closed
center (24 VDC)
SY3300-5U1 (1 set)
 P, E port entry
U U side (2 to 10 stations)
D D side (2 to 10 stations)
B Both sides (2 to 16 stations)

ide
 SUP/EXH block assembly
Us
Nil Internal pilot
s
n

S
tio

Internal pilot, Built-in silencer


ta
S

3 R External pilot
2
1 ∗ 3/5(E) port is plugged for the built-in silencer
e
D sid type.
∗ When the built-in silencer type is used, keep the
Manifold base (5 stations)
exhaust port from coming in direct contact with
SS5Y3-10SA2-05D-C6 water or other liquids.
SS5Y3-10SA2-05D-C6 ···1 set (Type 10 5-station manifold base part no.)
∗SY3100-5U1 ····················3 sets (2-position single part no.)
∗SY3200-5U1 ····················1 set (2-position double part no.)
∗SY3300-5U1 ····················1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.

• The valve arrangement is numbered as the 1st station from the D side. For details about the EX500 Gateway-type Serial
• Under the manifold part number, state the valves to be mounted in order from Transmission System, refer to the WEB catalog or the Best
the 1st station as shown in the figure above. If the arrangement becomes Pneumatics No. 1 and the Operation Manual. For details about
complicated, specify on a manifold specification sheet. part numbers of SI units to be mounted, refer to page 212 in
Note) When mixing top ported configurations, select from page 136. this catalog. Please download the Operation Manual via SMC
In this case, use caution as there is also output on the A and B port on base side. website, http://www.smcworld.com
Specify on a manifold specification sheet if plugs are required on the A and B port
on base side.

129
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
 A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)

Sub-plate
Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2  — — — — N1 ø1/8"  — — — —

Plug-in
C3 ø3.2  — — — — N3 ø5/32"   —  —

Straight
C4 ø4   —  — N7 ø1/4"     
Straight

C6 ø6      N9 ø5/16" —    
C8 ø8 —     N11 ø3/8" — —  — 
C10 ø10 — —  —  CM∗ Straight port, mixed sizes     
C12 ø12 — —  —  LN3 ø5/32"  — — — —
CM∗

Upward
Straight port, mixed sizes      LN7 ø1/4"   — — —

Metal Base
L4 ø4   — — — LN9 ø5/16" —  — — —
L6 ø6    — — LN11 ø3/8" — —  — —
Upward

Elbow Note)
L8 ø8 —   — — BN3 ø5/32"  — — — —

Downward
L10 ø10 — —  — — BN7 ø1/4"   — — —

Plug-in
L12 ø12 — —  — — BN9 ø5/16" —  — — —
Elbow Note)

B4 ø4   — — — BN11 ø3/8" — —  — —
Downward

B6 ø6    — — Elbow port, mixed sizes


LM∗ (Including upward and    — —
B8 ø8 —   — — downward piping)

B10 ø10 — —  — — P, E port size

Manifold Exploded View


ø5/16" ø3/8" ø1/2" ø3/8" ø1/2"
B12 ø12 — —  — — (One-touch fittings)

Type 50, 51, 52


Elbow port, mixed sizes
LM∗ (Including upward and    — —
downward piping)

P, E port size
ø8 ø10 ø12 ø10 ø12
(One-touch fittings)
Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 226 to 228).
∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting direction.

Connector Connecting Base


 Mounting and Option
Option
Symbol Mounting
Name plate Station number
Nil — —
Direct
AA mounting
 
BA  —

Plug-in
D — —
DIN rail
A mounting
 
B  —

Manifold Exploded View


Note 1) Enter the number of stations inside  when it

Type 10, 11, 12


is larger than the number of valve stations.
(Refer to “DIN Rail Option” below.)
Note 2) Only direct mounting is available for Type 11
(Bottom ported).
Note 3) Refer to page 247 for the fixation of DIN rail
mounting type manifold.
DIN Rail Option
Nil Direct mounting
Plug Assembly Part No.

0 Without DIN rail (with bracket)


One-touch Fittings/

3 For 3 stations Specify a longer rail


than the total length of
···

···

16 For 16 stations specified stations.


∗ When it is necessary to mount a DIN rail without
an SI unit, select D0 and order DIN rail length
separately, referring to L3 in the dimensions.
Manifold Options

(Refer to page 225 for part numbers of DIN rail.) Protective class
class III (Mark: )

130
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 0 0 5 1
          
Base mounted

 Series  Pilot valve option  Manual override


3 SY3000 Nil Standard (102psi (0.7 MPa)) Nil: D:
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Non-locking Push-turn
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa)) push type locking
∗ Only metal seal type is available for the high slotted
pressure type. type

 Type of actuation
1 Single  Coil type
2-position E: F:
2 Double Nil Standard Push-turn Slide locking
3 Closed center T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust center ∗ Be sure to select the power saving circuit type lever
5 Pressure center when the valve is continuously energized for type
A∗ N.C./N.C. long periods of time.
4-position ∗ Be careful of the energizing time when the
B∗ dual 3-port N.O./N.O.
power saving circuit is selected. Refer to page
C∗ N.C./N.O.
244 for details. ∗ Refer to page 14 for with the safety slide locking
∗ Only rubber seal type is available for the manual override.
4-position dual 3-port valve.
 Rated voltage
5 24 VDC
 Seal type  Type of mounting screw
Nil Round head combination screw
0 Rubber seal
B Hexagon socket head cap screw
1 Metal seal  Light/surge voltage suppressor Round head combination screw
K
and common specification (Falling-out-prevention type)
Surge voltage Common Hexagon socket head cap screw
Symbol With light H
 Pilot type suppressor specification (Falling-out-prevention type)
R — ∗ For “K” and “H”, the valve body cover has a drop
Nil Internal pilot Non-polar
U  prevention construction to stop the mounting
R External pilot screws from falling out when the valve is
S — Positive

common removed for maintenance etc.
Z 
∗ When ordering a valve individually, the base
NS — Negative gasket is not included. Since the base gasket is
 Back pressure check valve NZ  common attached to the manifold, please order the base
(Built-in valve type) ∗ Only “Z” and “NZ” types are available for with gasket separately if it is needed for maintenance
Nil None the power saving circuit. Select a valve from R, service.
U, S or Z when the SI unit specification is A2 Refer to page 220 for part numbers of the base
H Built-in
(positive common). Select a valve from R, U, NS gasket and mounting screw.
∗ Only rubber seal type. Manifold installed type is or NZ when the SI unit specification is A2N ∗ "B" and "H" cannot be selected for the individual
available if the back pressure check valve is (negative common). SUP/EXH spacer assembly, interface regulator
required for a valve with metal seal. Refer to or double check spacer assembly with residual
page 232 for Ordering Example. However, it is pressure release valve.
not recommended to use the built-in valve type
and the manifold installed type at the same time
because it will reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type and
the SY7000.

Protective class
class III (Mark: )

131
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY3000 Connector Connecting Base EX500

C2
U
C4, N3 (D)
SS5Y3-10SA2- Stations D - C3, N1

Sub-plate
B C6, N7

D side U side
Manual override Note 2)
(L5)
( )

Plug-in
L1 Push-turn locking slotted type:
DIN rail holding screw Press, then rotate it.
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
: Gray (For metal seal)
(Light/surge voltage suppressor) 2(B) port side : Yellow
SI unit

(5.5)
(8)

Metal Base
B A B A B A B A B A

(35)

92.6
14 A 14 A 14 A 14 A 14 A

83
67.8

60.5
(40.9)
12 B 12 B 12 B 12 B 12 B

Plug-in
4.6

4.6
1.7
)
(4.9)
C6: 3.6
N7: 7.4
12.1

4 x M4 mounting hole
(Fitting for the type with P/E ports on the U and/or D sides)
(

Manifold Exploded View


34.5 L2 1.5

Type 50, 51, 52


(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: ø8, ø5/16" [4(A), 2(B) port]
Applicable tube O.D.: ø2

Connector Connecting Base


(Station 1) --- (Station n)
M12 : ø3.2, ø1/8"
8-pin socket : ø4, ø5/32"
: ø6, ø1/4"
0
1 P 1 P
63.1
10.6
13.6

1
56.6
60

3/5 E 2 B2 B2 B2 B2 B 3/5 E
43.2
40.2
22.2

21.6

4 A4 A4 A4 A4 A
18

Plug-in
M12
(For DIN rail
(7.5)

mounting)

17.5 (Pitch)
8-pin plug
(11.8)

46.3 15.5 P = 10.5 (17.8)

Manifold Exploded View


Note 1) These figures show the “SS5Y3-10SA2-05D-C6”. Type 10, 11, 12
Note 2) Refer to page 181 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 186 for dimensions of A or B port top-ported type.
Plug Assembly Part No.
One-touch Fittings/

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 103.5 114 124.5 135 145.5 156 166.5 177 187.5 198 208.5 219 229.5 240 250.5
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210
L3 135.5 148 148 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5
Manifold Options

L4 125 137.5 137.5 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275
L5 16 17 12 13 14 15 16 17 18 12.5 13.5 14.5 15.5 16.5 17.5

132
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base EX500

U C4, N3
SS5Y5-10SA2- Stations D - C6, N7 (D)
B C8, N9

D side U side
Manual override Note 2)

DIN rail holding screw


(L5) L1
(
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor)
: Gray (For metal seal)
SI unit 2(B) port side : Yellow

DIN rail

(5.5)
(8)
BA BA BA BA BA

(35)
14 A 14 A 14 A 14 A 14 A

97.5
113.4
79.9

81.2
(61.7)
5.5
12 B 12 B 12 B 12 B 12 B

10.9
8.7

4.7
(5.9)
(8.3)

4 x M5 mounting hole

34 L2 1.5
(Fitting for the type with P/E
(5.3) (L4) ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: ø4, ø5/32"
Applicable tube O.D.: ø10, ø3/8" (Station 1) ----------- (Station n) : ø6, ø1/4"
: ø8, ø5/16"
M12
8-pin socket
0
1 P 1 P
14.1

73.2

2 B2 B2 B2 B2 B
1
56.6
60
43.2

3/5 E 3/5 E
33.4

29.1
22.2

4 A4 A4 A4 A4 A
12.4
8.7

(For DIN rail


mounting)
(7.5)

17.5
(11.8)

M12 (Pitch)
48 18 P = 16 (20.5)
8-pin plug

Note 1) These figures show the “SS5Y5-10SA2-05D-C8”.


Note 2) Refer to page 182 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 187 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 120.5 136.5 152.5 168.5 184.5 200.5 216.5 232.5 248.5 264.5 280.5 296.5 312.5 328.5 344.5
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304
L3 148 160.5 185.5 198 210.5 235.5 248 260.5 273 298 310.5 323 348 360.5 373
L4 137.5 150 175 187.5 200 225 237.5 250 262.5 287.5 300 312.5 337.5 350 362.5
L5 14 12 16.5 15 13 17.5 16 14 12.5 17 15 13.5 18 16 14.5

133
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY7000 Connector Connecting Base EX500

C6, N7
U
C10, N11 (D)
SS5Y7-10SA2- Stations D - C8, N9

Sub-plate
B C12

D side U side
(L5) L1 Manual override Note 2)

Plug-in
DIN rail holding screw (
Push-turn locking slotted type:
Press, then rotate it. )
SI unit (For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
: Gray (For metal seal)
(Light/surge voltage suppressor)
2(B) port side: Yellow

(8) (DIN rail)

Metal Base
B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A

128.8
115
79.9

(5.5)

96.7

Plug-in
(77.1)
12 B 12 B 12 B 12 B 12 B

5.5
24.1

Manifold Exploded View


8.8
3.9
(6)

Type 50, 51, 52


(9.3)

(A, B port: ø12) 4 x M5 mounting hole


(17.9)

34.2 L2 1.5 (Fitting for the type with P/E


(5.3) (L4) ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

Connector Connecting Base


One-touch fitting
[4(A), 2(B) port]
One-touch fitting
Applicable tube O.D.: ø6, ø1/4"
[1(P), 3/5(E) port] (Station 1) (Station n) : ø8, ø5/16"
Applicable tube O.D.: ø12, ø1/2" : ø10, ø3/8"
M12 : ø12
8-pin socket
2

0
1 P 1 P
82.7

2 B2 B2 B2 B2 B

Plug-in
1
56.6
60
43.2

3/5 E 3/5 E
11.1
8.7
35.2

31.6

4 A4 A4 A4 A4 A
22.2

Manifold Exploded View


Type 10, 11, 12
14.2

(For DIN rail

17.5 (Pitch) (21.7)


(10)

(14.3)

M12
mounting)

8-pin plug 53 20.5 P = 19

Note 1) These figures show the “SS5Y7-10SA2-05D-C10”.


Note 2) Refer to page 183 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Plug Assembly Part No.

Note 3) Refer to page 188 for dimensions of A or B port top-ported type.


One-touch Fittings/

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 134.7 153.7 172.7 191.7 210.7 229.7 248.7 267.7 286.7 305.7 324.7 343.7 362.7 381.7 400.7
L2 151 170 189 208 227 246 265 284 303 322 341 360
Manifold Options

94 113 132
L3 160.5 185.5 198 223 235.5 260.5 273 298 310.5 335.5 348 373 398 410.5 435.5
L4 150 175 187.5 212.5 225 250 262.5 287.5 300 325 337.5 362.5 387.5 400 425
L5 13 16 12.5 15.5 12.5 15.5 12 15 12 15 11.5 14.5 17.5 14.5 17.5

134
Plug-in Connector Connecting Base
EX500

Series SY3000/5000/7000
Type 12
Top Ported

RoHS
How to Order Manifold

SS5Y 3 12S A2 05 U
Refer to pages 186 to 188 for
dimensions of Type 12/Top
ported type.
      
 Series  P, E port entry  Valve stations
3 SY3000 U Note) U side (2 to 10 stations) Symbol Stations Note
5 SY5000 D Note) D side (2 to 10 stations) 02 2 stations
7 SY7000 B Both sides (2 to 16 stations) Double wiring Note 1)

···

···
Note) For type “S”, supply/exhaust block 08 8 stations
assembly with built-in silencer, choose U or 02 2 stations
 SI unit D for P port entry. Specified layout Note 2)

···

···
(Available up to 16 solenoids)
0 Without SI unit 16 16 stations
DeviceNet™/PROFIBUS DP/ Note 1) Double wiring: 2-position single, double,
A2 EtherNet/IP™  SUP/EXH block assembly 3-position and 4-position valves can be used on
(Positive common) Nil Internal pilot all manifold stations.
DeviceNet™/PROFIBUS DP/ S Internal pilot/Built-in silencer Use of a 2-position single solenoid will result in
A2N EtherNet/IP™ R External pilot an unused control signal. If this is not desired,
(Negative common) order with a specified layout.
∗ For built-in silencer type, P and E ports are Note 2) Specified layout: Indicate the wiring
Note) Ensure a match with the common available on U and D sides. 3/5(E) port is specifications on the manifold specification
specification of the valve to be used. plugged. The silencer exhaust port is located on sheet. (Note that 2-position double, 3-position
the opposite side of P, E port entry. (Example: and 4-position valves cannot be used where
When the P, E port entry is D side, the silencer single wiring has been specified.)
exhaust port is U side.) Note 3) This also includes the number of blanking plate
∗ When the built-in silencer type is used, keep the assembly.
exhaust port from coming in direct contact with Note 4) For the product without the SI unit (S0), note the
water or other liquids. maximum number of solenoids of the SI unit that
will be mounted. If the layout is specified,
How to Order Manifold Assembly indicate it on the manifold specification sheet.

Example (SS5Y3-12SA2-)
2-position double (24 VDC)
SY3230-5U1-C6 (1 set)
 P, E port size (One-touch fittings)
2-position single (24 VDC) Symbol SY3000 SY5000 SY7000
SY3130-5U1-C6 (3 sets) 3-position closed
center (24 VDC) Nil ø8 ø10 ø12
SY3330-5U1-C6 (1 set)
N ø5/16" ø3/8" ø1/2"
∗ For N, sizes are in inches.

 Mounting
sid
e Nil Direct mounting
U DIN rail mounting
D
s
n

(With DIN rail)


tio
ta
S

3 DIN rail mounting


2 D0 (Without DIN rail)
1
ide D3
Manifold base Ds For 3 stations
Specify a longer rail than
···

···

(5 stations) the standard length.


SS5Y3-12SA2-05D D16 For 16 stations
Note 1) When mounted on the DIN rail without the SI unit, please
SS5Y3-12SA2-05D ···1 set (Type 12 5-station manifold base part no.) select D0 and refer to L3 of the dimensions for the DIN rail
∗SY3130-5U1-C6 ········3 sets (2-position single part no.) length, then order separately. (Refer to page 225 for the
∗SY3230-5U1-C6 ········1 set (2-position double part no.) DIN rail part number.)
∗SY3330-5U1-C6 ········1 set (3-position closed center part no.) Note 2) Refer to page 247 for the fixation of DIN rail mounting type
manifold.
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
For details about the EX500 Gateway-type Serial
• The valve arrangement is numbered as the 1st station from the D side. Transmission System, refer to the WEB catalog or the Best
• Under the manifold part number, state the valves to be mounted in order Pneumatics No. 1 and the Operation Manual. For details about
from the 1st station as shown in the figure above. If the arrangement part numbers of SI units to be mounted, refer to page 212 in
becomes complicated, specify on a manifold specification sheet. this catalog. Please download the Operation Manual via SMC
website, http://www.smcworld.com

135
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
            

Plug-in
Top ported

 Series  Pilot valve option  A, B port size


3 SY3000 Nil Standard (102 psi (0.7 MPa)) Thread piping
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Symbol Port size Applicable series
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa)) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000

Metal Base
pressure type. 02 1/4 SY7000
 Type of actuation  Coil type One-touch fitting (Metric)
1 Single Symbol A, B port SY3000 SY5000 SY7000
2-position Nil Standard
2 Double C2 ø2  — —
T With power saving circuit (Continuous duty type)

Plug-in
3 Closed center C3 ø3.2  — —
∗ Be sure to select the power saving circuit type
4 3-position Exhaust center when the valve is continuously energized for
C4 ø4   —
5 Pressure center long periods of time. C6 ø6   
A∗ N.C./N.C. ∗ Be careful of the energizing time when the C8 ø8 —  
4-position
B∗ dual 3-port N.O./N.O. power saving circuit is selected. Refer to page C10 ø10 — — 
C∗ 244 for details. C12

Manifold Exploded View


N.C./N.O. ø12 — — 

Type 50, 51, 52


∗ Only rubber seal type is available for the One-touch fitting (Inch)
4-position dual 3-port valve.  Rated voltage Symbol A, B port SY3000 SY5000 SY7000
5 24 VDC N1 ø1/8"  — —
N3 ø5/32"   —
 Seal type  Light/surge voltage suppressor N7 ø1/4"   
0 N9 ø5/16" —  
Rubber seal and common specification
1 Metal seal
N11 ø3/8" — — 
Surge voltage Common
Symbol With light

Connector Connecting Base


suppressor specification
R —
Non-polar
 Pilot type U   Thread type
S — Positive Nil Rc
Nil Internal pilot 
common
Z  F G
R External pilot
NS — Negative N NPT
NZ  common T NPTF
∗ Only “Z” and “NZ” types are available for with ∗ Only Nil is available for M5.
 Back pressure check valve the power saving circuit. Select a valve from R,

Plug-in
U, S or Z when the SI unit specification is A2
(Built-in valve type) (positive common). Select a valve from R, U, NS
Nil None or NZ when the SI unit specification is A2N  Type of mounting screw
H Built-in (negative common).

Manifold Exploded View


Nil Round head combination screw
∗ Only rubber seal type. Manifold installed type is

Type 10, 11, 12


available if the back pressure check valve is
B Hexagon socket head cap screw
Round head combination screw
required for a valve with metal seal. Refer to  Manual override K (Falling-out-prevention type)
page 232 for Ordering Example. However, it is
not recommended to use the built-in valve type Nil: D: Hexagon socket head cap screw
H (Falling-out-prevention type)
and the manifold installed type at the same time Non-locking Push-turn
because it will reduce the flow. push type locking slotted
∗ For “K” and “H”, the valve body cover has a drop
∗ The built-in valve type back pressure check type
prevention construction to stop the mounting
valve is not available for the 3-position type and
screws from falling out when the valve is
the SY7000.
removed for maintenance etc.
Plug Assembly Part No.
One-touch Fittings/

∗ When ordering a valve individually, the base


gasket is not included. Since the base gasket is
E: F: attached to the manifold, please order the base
Push-turn Slide locking gasket separately if it is needed for maintenance
locking lever type service.
type Refer to page 220 for part numbers of the base
gasket and mounting screw.
Manifold Options

∗ "B" and "H" cannot be selected for the individual


SUP/EXH spacer assembly or interface
regulator.

∗ Refer to page 14 for with the safety slide locking


manual override. Protective class
class III (Mark: )

136
Type 10
Side Ported
Plug-in Connector Connecting Base
RoHS
EX600

Series SY3000/5000/7000
Type 11
Bottom Ported

How to Order Manifold

Refer to pages 184 (SY5000) and


SS5Y 3 10 S6 Q 2 05 U C6
185 (SY7000) for dimensions of
Type 11/Bottom ported type.         
 Series  I/O unit stations  Mounting and Option
3 SY3000 Nil None Option
Symbol Mounting
5 SY5000 1 1 station Name plate Station number
7 SY7000 Nil — —
···

···
Direct
9 9 stations AA mounting
 
Note 1) Without SI unit, the symbol is nil. BA  —
 Type Note 2) SI unit is not included in I/O unit stations.
Note 3) When I/O unit is selected, it is shipped
D
DIN rail
— —
A  
10 Side ported separately, and assembled by users. mounting
B  —
11 Bottom ported∗ Refer to the attached operation manual for
mounting. Note 1) Enter the number of stations inside 
∗ The SY5000 manifold base is used for the
when it is larger than the number of valve
bottom ported of the SY3000. When ordering,
stations. (Refer to “DIN Rail Option”
refer to “Plug-in Mixed Mounting Type Manifold”
below.)
(from page 189).
 Valve stations Note 2) Only direct mounting is available for Type
11 (Bottom ported).
Symbol Stations Note Note 3) Refer to page 247 for the fixation of DIN
 SI unit 02 2 stations rail mounting type manifold.
0 Without SI unit Double wiring Note 1)
···

···

DIN Rail Option


Q DeviceNet™ 16 16 stations Nil Direct mounting
N PROFIBUS DP 02 2 stations 0 Without DIN rail (with bracket)
Specified layout Note 2)
V CC-Link
···

···

(Available up to 32 solenoids) 3 For 3 stations


ZE EtherNet/IP™ 24 24 stations Specify a longer rail than the

···
···

D EtherCAT Note 1) Double wiring: 2-position single, double, 24 For 24 stations


total length of specified stations.
F PROFINET 3-position and 4-position valves can be
∗ If the DIN rail must be mounted without an SI
Note 1) I/O unit cannot be mounted without SI used on all manifold stations.
unit, select D0. Then, refer to L3 of the
unit. Use of a 2-position single solenoid will
dimensions for the DIN rail length and order
Note 2) Valve plate which connects manifold and result in an unused control signal. If this is
separately. (Refer to page 225 for the DIN rail
SI unit is not mounted to a valve without SI not desired, order with a specified layout.
part number.)
unit. Refer to the EX600 catalog Note 2) Specified layout: Indicate the wiring
(CAT.E02-24) for mounting. specifications on the manifold specification
sheet. (Note that 2-position double,
3-position and 4-position valves cannot be
used where single wiring has been
specified.)
Note 3) This also includes the number of blanking
 SI unit output polarity, end plate type plate assembly.
Power supply Power supply
SI unit output polarity with M12 with 7/8 inch
connector connector
Without SI unit Nil  P, E port entry, SUP/EXH block assembly
SI unit positive common 2 3 Internal Internal pilot, External
SI unit negative common 4 5 P, E port entry
pilot Built-in silencer pilot
Note 1) Ensure a match with the common U side (2 to 10 stations) U C G
specification of the valve to be used. D side (2 to 10 stations) D E H
Note 2) Without SI unit, the symbol is nil.
Both sides (2 to 24 stations) B F J
∗ 3/5(E) port is plugged for the built-in silencer type.
∗ When the built-in silencer type is used, keep the exhaust port from coming in
direct contact with water or other liquids.

Refer to the page on the right for .

For details about the EX600 Integrated-type (For Input/Output) Serial


Transmission System, refer to the WEB catalog or the Best Pneumatics No. 1
and the Operation Manual. For details about part numbers of SI units to be
mounted, refer to pages 213 and 214 in this catalog. (IP40 specifications may be
required according to the I/O unit to be selected.) Please download the Operation
Manual via SMC website, http://www.smcworld.com

137
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)

Sub-plate
Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2  — — — — N1 ø1/8"  — — — —

Plug-in
C3 ø3.2  — — — — N3 ø5/32"   —  —

Straight
C4 ø4   —  — N7 ø1/4"     
Straight

C6 ø6      N9 ø5/16" —    
C8 ø8 —     N11 ø3/8" — —  — 
C10 ø10 — —  —  CM∗ Straight port, mixed sizes     
C12 ø12 — —  —  LN3 ø5/32"  — — — —
CM∗

Upward
Straight port, mixed sizes      LN7 ø1/4"   — — —

Metal Base
L4 ø4   — — — LN9 ø5/16" —  — — —
L6 ø6    — — LN11 ø3/8" — —  — —
Upward

Elbow Note)
L8 ø8 —   — — BN3 ø5/32"  — — — —

Downward
L10 ø10 — —  — — BN7 ø1/4"   — — —

Plug-in
L12 ø12 — —  — — BN9 ø5/16" —  — — —
Elbow Note)

B4 ø4   — — — BN11 ø3/8" — —  — —
Downward

B6 ø6    — — Elbow port, mixed sizes


LM∗ (Including upward and    — —
B8 ø8 —   — — downward piping)

B10 ø10 — —  — — P, E port size


ø5/16" ø3/8"

Manifold Exploded View


ø1/2" ø3/8" ø1/2"
B12 ø12 — —  — — (One-touch fittings)

Type 50, 51, 52


Elbow port, mixed sizes
LM∗ (Including upward and    — —
downward piping)

P, E port size
ø8 ø10 ø12 ø10 ø12
(One-touch fittings)
Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 226 to 228).
∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting direction.

Connector Connecting Base


How to Order Manifold Assembly

Example (SS5Y3-10S6-) SS5Y3-10S6Q42-05B-C6 ···1 set (Type 10 5-station manifold base part no.)
∗SY3100-5U1 ·······················3 sets (2-position single part no.)
∗SY3200-5U1 ·······················2 sets (2-position double part no.)

Plug-in
Digital input unit Digital output unit 2-position single ∗EX600-DXPD ·····················1 set I/O unit part number (Station 1)
EX600-DXPD EX600-DYPB SY3100-5U1 (3 sets) ∗EX600-DYPB ·····················1 set I/O unit part number (Station 2)
End plate Note 1) SI unit Note 1) 2-position double The asterisk denotes the symbol for assembly.

Manifold Exploded View


EX600-ED2 EX600-SDN1 SY3200-5U1 (2 sets) Prefix it to the part numbers of the valve etc.

Type 10, 11, 12


0 1 • The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted, then the I/O
2 3
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A units in order from the 1st station as shown in the figure above.
D side
PWR
OUT U side If the arrangement becomes complicated, specify on a manifold specification
0 1
4 5 sheet.
2 3 12 B 12 B 12 B 12 B 12 B
PCI
BUS BUS
IN OUT
Note 1) Do not enter the SI unit part number and the end plate part number
8 7
together.
Note 2) When mixing top ported configurations, select from page 148.
1 2 3 4 5 Valve stations
Plug Assembly Part No.

In this case, use caution as there is also output on the A and B port on
1 2 I/O unit stations
One-touch Fittings/

base side.
Specify on a manifold specification sheet if plugs are required on the A and
B port on base side.
Manifold Options

Protective class
class III (Mark: )

138
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 0 0 5 1
          
Base mounted

 Series  Pilot valve option  Manual override


3 SY3000 Nil Standard (102 psi (0.7 MPa) Nil: D:
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Non-locking Push-turn
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa)) push type locking
∗ Only metal seal type is available for the high slotted
pressure type. type

 Type of actuation
1 Single  Coil type
2-position E: F:
2 Double Nil Standard Push-turn Slide locking
3 Closed center T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust center ∗ Be sure to select the power saving circuit type lever
5 Pressure center when the valve is continuously energized for type
A∗ N.C./N.C. long periods of time.
4-position ∗ Be careful of the energizing time when the
B∗ dual 3-port
N.O./N.O.
power saving circuit is selected. Refer to page
C∗ N.C./N.O.
244 for details. ∗ Refer to page 14 for with the safety slide locking
∗ Only rubber seal type is available for the manual override.
4-position dual 3-port valve.
 Rated voltage
5 24 VDC

 Seal type  Type of mounting screw


Nil Round head combination screw
0 Rubber seal
1 Metal seal
 Light/surge voltage suppressor B Hexagon socket head cap screw
and common specification Round head combination screw
K (Falling-out-prevention type)
Surge voltage Common
Symbol With light Hexagon socket head cap screw
suppressor specification H
(Falling-out-prevention type)
 Pilot type R —
Non-polar
Nil Internal pilot U  ∗ For “K” and “H”, the valve body cover has a drop
R External pilot S — Positive prevention construction to stop the mounting
 screws from falling out when the valve is
Z  common
removed for maintenance etc.
NS — Negative ∗ When ordering a valve individually, the base
NZ  common gasket is not included. Since the base gasket is
 Back pressure check valve ∗ Select a valve from R, U, S or Z when the SI unit attached to the manifold, please order the base
(Built-in valve type) polarity is positive common. Select a valve from gasket separately if it is needed for maintenance
Nil None R, U, NS or NZ when the SI unit output polarity service.
H Built-in is negative common. Refer to page 220 for part numbers of the base
∗ Only rubber seal type. Manifold installed type is ∗ Only “Z” and “NZ” types are available for with gasket and mounting screw.
the power saving circuit. ∗ "B" and "H" cannot be selected for the individual
available if the back pressure check valve is
SUP/EXH spacer assembly, interface regulator
required for a valve with metal seal. Refer to
or double check spacer assembly with residual
page 232 for Ordering Example. However, it is
pressure release valve.
not recommended to use the built-in valve type
and the manifold installed type at the same time
because it will reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type and
the SY7000.

Protective class
class III (Mark: )

139
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY3000 Connector Connecting Base EX600 (M12 Connector)

U C2
SS5Y3-10S6 42 - Stations D - C3,
C4, N3 (D)
N1

Sub-plate
B C6, N7
D side (L3) U side
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5) Manual override Note 2)

Plug-in
(L5) L1
DIN rail holding screw 5.5 L6 L2 ( Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 47 8 DIN rail holding screw 1.5 4(A) port side
Communication connector
(For DIN rail mounting) : Blue (For rubber seal)
Power connector 2 x M4 mounting hole : Gray (For metal seal)
85.1 (Light/surge 2(B) port side : Yellow
Marker groove
voltage suppressor)

0 1

(5.5)

Metal Base
B A B A B A B A B A
2 3

(35)

92.6
14 A 14 A 14 A 14 A 14 A

83
106

PWR
90

OUT

60.5
0 1

(40.9)
4 5
2 3

Plug-in
4.6
(8)
12 B 12 B 12 B 12 B 12 B
BUS PCI BUS
IN OUT

8 7
8

1.7

4.6
)
(4.9)

C6: 3.6
N7: 7.4
86.6 FE
terminal 5.4 4 x M4 mounting hole

Manifold Exploded View


End plate (Fitting for the type with P/E

Type 50, 51, 52


Digital input unit ports on the U and/or D sides)
Valve plate
Input connector
SI unit
Output connector One-touch fitting
Digital output unit Connector for handheld terminal [4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
(Station 1) --- (Station n) : ø4, ø5/32"
11.5

: ø6, ø1/4"

Connector Connecting Base


8

1 P 1 P

63.1
56.6

3/5 E 2 B2 B2 B2 B2 B 3/5 E
13.2

40.2
21.6
4 A4 A4 A4 A4 A

18
10.6
13.6
(For DIN rail

(7.5)
mounting)

One-touch fitting
(Pitch)
(11.8)

Plug-in
[1(P), 3/5(E) port] 18.3 15.5 P = 10.5 (17.8)
Applicable tube O.D.: ø8, ø5/16"

L1 = 10.5 x n1 + 135.5 + 47 x n2 Note 1) These figures show the “SS5Y3-10S6Q22-05D-C6”.

Manifold Exploded View


L2 = 10.5 x n1 + 42 Note 2) Refer to page 181 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

Type 10, 11, 12


L4 = L3 – 10.5 Note 3) Refer to page 186 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 47 x n2 + 82
n1: Valve stations
n2: I/O unit stations
L3: DIN Rail Overall Length
Valve
stations
Plug Assembly Part No.

I/O (n1) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
One-touch Fittings/

unit
stations
(n2)
0 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423
1 235.5 248 248 260.5 273 285.5 298 310.5 323 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5 448 448 460.5
2 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 410.5 423 435.5 448 460.5 473 485.5 485.5 498 510.5
3 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5 448 448 460.5 473 485.5 498 510.5 510.5 523 535.5 548 560.5
Manifold Options

4 373 385.5 398 410.5 410.5 423 435.5 448 460.5 473 473 485.5 498 510.5 523 535.5 548 548 560.5 573 585.5 598 610.5
5 423 435.5 448 448 460.5 473 485.5 498 510.5 510.5 523 535.5 548 560.5 573 573 585.5 598 610.5 623 635.5 635.5 648
6 473 473 485.5 498 510.5 523 535.5 535.5 548 560.5 573 585.5 598 610.5 610.5 623 635.5 648 660.5 673 673 685.5 698
7 510.5 523 535.5 548 560.5 573 573 585.5 598 610.5 623 635.5 635.5 648 660.5 673 685.5 698 698 710.5 723 735.5 748
8 560.5 573 585.5 598 598 610.5 623 635.5 648 660.5 673 673 685.5 698 710.5 723 735.5 735.5 748 760.5 773 785.5 798
9 610.5 623 635.5 635.5 648 660.5 673 685.5 698 698 710.5 723 735.5 748 760.5 760.5 773 785.5 798 810.5 823 835.5 835.5

140
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY3000 Connector Connecting Base EX600 (7/8 Inch Connector)

U C2
SS5Y3-10S6 53 - Stations D - C3,
C4, N3 (D)
N1
B C6, N7
D side (L3) U side
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L5) L1 Manual override Note 2)

DIN rail holding screw


5.5 L6 L2 ( Push-turn locking slotted type:
Press, then rotate it. )
Communication connector 47 8 DIN rail holding screw 1.5 4(A) port side
(For DIN rail mounting) (For DIN rail mounting) : Blue (For rubber seal)
2 x M4 mounting hole
(Light/surge : Gray (For metal seal)
Marker groove 2(B) port side : Yellow
voltage suppressor)

0 1

(5.5)
B A B A B A B A B A
2 3

(35)

92.6
14 A 14 A 14 A 14 A 14 A

83
106
90

60.5
0 1

(40.9)
4 5
PWR

2 3

4.6
(8)
12 B 12 B 12 B 12 B 12 B
BUS PCI BUS
53

IN OUT

8 7

4.6
1.7
8

)
(4.9)

C6: 3.6
N7: 7.4
36.7 FE
terminal 5.4 4 x M4 mounting hole

(
Power connector End plate
(Fitting for the type with P/E
Digital input unit ports on the U and/or D sides)
Valve plate
Input connector One-touch fitting
Output connector SI unit [4(A), 2(B) port]
Applicable tube O.D.: ø2
Digital output unit Connector for handheld terminal : ø3.2, ø1/8"
: ø4, ø5/32"
11.5

(Station 1)---(Station n)
: ø6, ø1/4"
8

1 P 1 P

63.1
56.6

3/5 E 2 B2 B2 B2 B2 B 3/5 E
13.2

40.2
21.6
4 A4 A4 A4 A4 A

18
10.6
13.6
(For DIN rail

(7.5)

One-touch fitting
mounting)

(Pitch)
(11.8)

[1(P), 3/5(E) port] 18.3 15.5 P = 10.5 (17.8)


Applicable tube O.D.: ø8, ø5/16"

Note 1) These figures show the “SS5Y3-10S6Q32-05D-C6”.


L1 = 10.5 x n1 + 152 + 47 x n2 Note 2) Refer to page 181 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
L2 = 10.5 x n1 + 42 Note 3) Refer to page 186 for dimensions of A or B port top-ported type.
L4 = L3 – 10.5
L5 = (L3 – L1)/2
L6 = 47 x n2 + 82
n1: Valve stations
n2: I/O unit stations
L3: DIN Rail Overall Length
Valve
stations
I/O (n1)
unit 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 198 210.5 223 235.5 248 260.5 260.5 273 285.5 298 310.5 323 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5
1 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 360.5 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5
2 298 310.5 323 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5 448 448 460.5 473 485.5 498 510.5 523 523
3 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548 548 560.5 573
4 385.5 398 410.5 423 435.5 448 448 460.5 473 485.5 498 510.5 510.5 523 535.5 548 560.5 573 585.5 585.5 598 610.5 623
5 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548 548 560.5 573 585.5 598 610.5 610.5 623 635.5 648 660.5 673
6 485.5 498 510.5 510.5 523 535.5 548 560.5 573 573 585.5 598 610.5 623 635.5 648 648 660.5 673 685.5 698 710.5 710.5
7 535.5 548 548 560.5 573 585.5 598 610.5 610.5 623 635.5 648 660.5 673 673 685.5 698 710.5 723 735.5 735.5 748 760.5
8 573 585.5 598 610.5 623 635.5 635.5 648 660.5 673 685.5 698 710.5 710.5 723 735.5 748 760.5 773 773 785.5 798 810.5
9 623 635.5 648 660.5 673 673 685.5 698 710.5 723 735.5 735.5 748 760.5 773 785.5 798 798 810.5 823 835.5 848 860.5

141
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base EX600 (M12 Connector)

U C4, N3
SS5Y5-10S6 42 - Stations D - C6, N7 (D)

Sub-plate
B C8, N9
D side
(L3)
U side
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
DIN rail holding screw

Plug-in
(L5) L1 Manual override Note 2)
(For DIN rail mounting)
Power connector
5.5
Communication connector
L6 L2
( Push-turn locking slotted type:
Press, then rotate it. )
47 8 DIN rail holding screw 1.5 4(A) port side
DIN rail
2 x M4 mounting hole (For DIN rail mounting) : Blue (For rubber seal)
(Light/surge voltage suppressor) : Gray (For metal seal)
85.1 Marker groove 2(B) port side : Yellow

0 1

Metal Base
(5.5)
BA BA BA BA BA
2 3

(35)
14 A 14 A 14 A 14 A 14 A

97.5
113.4
PWR
90

OUT
0 1
4 5

81.2
2 3

Plug-in
PCI (8)

(61.7)
BUS BUS
IN OUT

5.5
7.4

12 B 12 B 12 B 12 B 12 B
8 7

10.9
15.4

4.7
(5.9)
(8.3)

Manifold Exploded View


86.6 FE terminal 5.4

Type 50, 51, 52


4 x M5 mounting hole
End plate
(Fitting for the type with P/E
Digital input unit
ports on the U and/or D sides)
Valve plate
Input connector
One-touch fitting
SI unit
Output connector [4(A), 2(B) port]
Connector for handheld terminal Applicable tube O.D.: ø4, ø5/32"
Digital output unit : ø6, ø1/4"
(Station 1) ---------- (Station n) : ø8, ø5/16"

Connector Connecting Base


11.5

1 P 1 P

73.2
2 B2 B2 B2 B2 B
56.6

13.2

3/5 E 3/5 E

33.4
29.1
4 A4 A4 A4 A4 A
12.4
14.1
8.7

One-touch fitting
(7.5)
(For DIN rail
mounting)

Plug-in
[1(P), 3/5(E) port] (Pitch)
(11.8)

Applicable tube O.D.: ø10, ø3/8" 20 18 P = 16 (20.5)

Manifold Exploded View


L1 = 16 x n1 + 141.5 + 47 x n2 Note 1) These figures show the “SS5Y5-10S6Q22-05D-C8”.

Type 10, 11, 12


L2 = 16 x n1 + 48 Note 2) Refer to page 182 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
L4 = L3 – 10.5 Note 3) Refer to page 187 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 47 x n2 + 81.5
n1: Valve stations
n2: I/O unit stations
L3: DIN Rail Overall Length
Valve
stations
Plug Assembly Part No.

I/O (n1)
One-touch Fittings/

unit 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 198 223 235.5 248 273 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 560.5
1 248 260.5 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598
2 298 310.5 323 348 360.5 373 398 410.5 423 435.5 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 623 635.5 648
3 348 360.5 373 398 410.5 423 435.5 460.5 473 485.5 498 523 535.5 548 573 585.5 598 610.5 635.5 648 660.5 685.5 698
Manifold Options

4 385.5 410.5 423 435.5 460.5 473 485.5 498 523 535.5 548 573 585.5 598 610.5 635.5 648 660.5 673 698 710.5 723 748
5 435.5 448 473 485.5 498 523 535.5 548 560.5 585.5 598 610.5 635.5 648 660.5 673 698 710.5 723 748 760.5 773 785.5
6 485.5 498 523 535.5 548 560.5 585.5 598 610.5 623 648 660.5 673 698 710.5 723 735.5 760.5 773 785.5 810.5 823 835.5
7 535.5 548 560.5 585.5 598 610.5 623 648 660.5 673 698 710.5 723 735.5 760.5 773 785.5 798 823 835.5 848 873 885.5
8 573 598 610.5 623 648 660.5 673 685.5 710.5 723 735.5 760.5 773 785.5 798 823 835.5 848 873 885.5 898 910.5 935.5
9 623 648 660.5 673 685.5 710.5 723 735.5 748 773 785.5 798 823 835.5 848 860.5 885.5 898 910.5 935.5 948 960.5 973

142
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base EX600 (7/8 Inch Connector)

U C4, N3
SS5Y5-10S6 53 - Stations D - C6, N7 (D)
B C8, N9
D side (L3) U side
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L5) L1 Manual override Note 2)

DIN rail holding screw


5.5 L6 L2 ( Push-turn locking slotted type:
Press, then rotate it. )
16.5 2 x M4 mounting hole 47 8 DIN rail holding screw 1.5 4(A) port side
(For DIN rail mounting) Communication connector (For DIN rail mounting) : Blue (For rubber seal)
(Light/surge voltage suppressor) : Gray (For metal seal)
DIN rail Marker groove 2(B) port side: Yellow

0 1

(5.5)
BA BA BA BA BA
2 3

(35)
14 A 14 A 14 A 14 A 14 A
90

97.5
0 1

113.4
4 5

81.2
PWR

2 3
PCI (8)

(61.7)
BUS BUS
60.4

IN OUT

5.5
7.4

12 B 12 B 12 B 12 B 12 B
8 7

10.9
15.4

4.7
(5.9)
(8.3)
36.7
Power connector FE terminal 5.4 4 x M5 mounting hole

End plate (Fitting for the type with P/E


ports on the U and/or D sides)
Digital input unit
Valve plate
Input connector One-touch fitting
SI unit
[4(A), 2(B) port]
Output connector Connector for handheld terminal Applicable tube O.D.: ø4, ø5/32"
Digital output unit (Station 1) ---------- (Station n) : ø6, ø1/4"
: ø8, ø5/16"
11.5

1 P 1 P

73.2
2 B2 B2 B2 B2 B
56.6

13.2

3/5 E 3/5 E

33.4
29.1
4 A4 A4 A4 A4 A

14.1
12.4
8.7
(For DIN rail

(7.5)
mounting)

One-touch fitting (Pitch)


(11.8)

[1(P), 3/5(E) port] 20 18 P = 16 (20.5)


Applicable tube O.D.: ø10, ø3/8"

L1 = 16 x n1 + 158 + 47 x n2 Note 1) These figures show the “SS5Y5-10S6Q32-05D-C8”.


L2 = 16 x n1 + 48 Note 2) Refer to page 182 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
L4 = L3 – 10.5 Note 3) Refer to page 187 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 47 x n2 + 81.5
n1: Valve stations
n2: I/O unit stations

L3: DIN Rail Overall Length


Valve
stations
I/O (n1)
unit 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 223 235.5 248 273 285.5 298 310.5 335.5 348 360.5 385.5 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 560.5 573
1 260.5 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 560.5 573 585.5 598 623
2 310.5 335.5 348 360.5 373 398 410.5 423 435.5 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 623 635.5 648 660.5
3 360.5 373 398 410.5 423 435.5 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 610.5 635.5 648 660.5 685.5 698 710.5
4 410.5 423 435.5 460.5 473 485.5 498 523 535.5 548 573 585.5 598 610.5 635.5 648 660.5 685.5 698 710.5 723 748 760.5
5 460.5 473 485.5 498 523 535.5 548 560.5 585.5 598 610.5 635.5 648 660.5 673 698 710.5 723 748 760.5 773 785.5 810.5
6 498 523 535.5 548 560.5 585.5 598 610.5 635.5 648 660.5 673 698 710.5 723 735.5 760.5 773 785.5 810.5 823 835.5 848
7 548 560.5 585.5 598 610.5 623 648 660.5 673 698 710.5 723 735.5 760.5 773 785.5 810.5 823 835.5 848 873 885.5 898
8 598 610.5 623 648 660.5 673 685.5 710.5 723 735.5 760.5 773 785.5 798 823 835.5 848 873 885.5 898 910.5 935.5 948
9 648 660.5 673 685.5 710.5 723 735.5 760.5 773 785.5 798 823 835.5 848 860.5 885.5 898 910.5 935.5 948 960.5 973 —

143
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY7000 Connector Connecting Base EX600 (M12 Connector)

U C6, N7
SS5Y7-10S6 42 - Stations D - C8,
C10, N11 (D)
N9

Sub-plate
B C12 (L3)
D side U side
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
Manual override Note 2)
DIN rail holding screw (L5) L1

Plug-in
(For DIN rail mounting)
Power connector
5.5 L6 L2 ( Push-turn locking slotted
type: Press, then rotate it. )
2 x M4 mounting hole 47 8 DIN rail holding screw 1.5 4(A) port side
(DIN rail) Communication connector (For DIN rail mounting) : Blue (For rubber seal)
: Gray (For metal seal)
Marker groove Valve plate Light/surge voltage suppressor 2(B) port side: Yellow
85.1

0 1

(5.5)

Metal Base
B A B A B A B A B A
2 3

(35)
14 A 14 A 14 A 14 A 14 A
PWR
90

OUT

128.8
115
0 1
4 5
2 3
FE PCI
(8)

96.7
BUS BUS
IN OUT
terminal

Plug-in
(77.1)
8 7
12 B 12 B 12 B 12 B 12 B

5.5
30.8
22.8

5.4

8.8
3.9
(6)
86.6 SI unit

Manifold Exploded View


(9.3) 4 x M5 mounting hole
(A, B port: ø12)

(17.9)

Type 50, 51, 52


End plate Connector for (Fitting for the type with P/E
handheld terminal ports on the U and/or D sides)
Digital input unit Digital output unit
One-touch fitting
Input connector Output connector [4(A), 2(B) port]
(Station 1) (Station n) Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
: ø10, ø3/8"
: ø12
11.5

Connector Connecting Base


2
8

82.7
1 P 1 P
2 B2 B2 B2 B2 B
(56.6)

56.6
13.2

3/5 E 3/5 E

35.2
31.6
4 A4 A4 A4 A4 A

11.1
14.2
8.7

(Pitch)
(For DIN rail

(10)
(14.3)

mounting)

One-touch fitting 25 20.5 P = 19 (21.7)

Plug-in
[1(P), 3/5(E) port]
Applicable tube O.D.: ø12, ø1/2"

L1 = 19 x n1 + 149.7 + 47 x n2 Note 1) These figures show the “SS5Y7-10S6Q22-05D-C10”.

Manifold Exploded View


L2 = 19 x n1 + 56 Note 2) Refer to page 183 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

Type 10, 11, 12


L3 = DIN rail dimension Note 3) Refer to page 188 for dimensions of A or B port top-ported type.
L4 = L3 – 10.5
L5 = (L3 – L1)/2
L6 = 47 x n2 + 81.7
n1: Valve stations
n2: I/O unit stations

L3: DIN Rail Overall Length


Valve
Plug Assembly Part No.

I/O stations
One-touch Fittings/

unit (n1) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 223 235.5 260.5 273 298 310.5 335.5 348 373 385.5 410.5 423 448 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5
1 260.5 285.5 298 323 335.5 360.5 373 398 410.5 435.5 448 473 498 510.5 535.5 548 573 585.5 610.5 623 648 660.5 685.5
2 310.5 335.5 348 373 385.5 410.5 423 448 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5 648 673 685.5 710.5 723
3 360.5 373 398 410.5 435.5 448 473 485.5 510.5 523 548 573 585.5 610.5 623 648 660.5 685.5 698 723 735.5 760.5 773
Manifold Options

4 410.5 423 448 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5 798 823
5 448 473 485.5 510.5 523 548 560.5 585.5 598 623 648 660.5 685.5 698 723 735.5 760.5 773 798 810.5 835.5 848 873
6 498 523 535.5 560.5 573 598 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5 798 823 835.5 860.5 873 898 923
7 548 560.5 585.5 598 623 635.5 660.5 673 698 723 735.5 760.5 773 798 810.5 835.5 848 873 885.5 910.5 923 948 960.5
8 598 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5 798 823 835.5 860.5 873 898 910.5 935.5 948 973 — —
9 635.5 660.5 673 698 710.5 735.5 748 773 798 810.5 835.5 848 873 885.5 910.5 923 948 960.5 985.5 — — — —

144
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY7000 Connector Connecting Base EX600 (7/8 Inch Connector)

U C6, N7
SS5Y7-10S6 53 - Stations D - C8,
C10, N11 (D)
N9
B C12
D side (L3) U side
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L5) L1 Manual override Note 2)

DIN rail holding screw


5.5
16.5 2 x M4 mounting hole
L6
47 8 DIN rail holding screw
L2
1.5
( Push-turn locking slotted
type: Press, then rotate it. )
(For DIN rail mounting) 4(A) port side
Communication connector (For DIN rail mounting) : Blue (For rubber seal)
Power connector (DIN rail) Light/surge voltage suppressor : Gray (For metal seal)
Marker groove
2(B) port side: Yellow

0 1

(5.5)
B A B A B A B A B A

(35)
2 3
14 A 14 A 14 A 14 A 14 A
90

128.8
115
0 1
4 5
PWR

2 3
FE PCI

96.7
BUS BUS
IN OUT (8)
terminal

(77.1)
75.8

8 7

5.5
12 B 12 B 12 B 12 B 12 B
31
22.8

5.4

8.8
End plate

3.9
36.7

(6)
(9.3)
(A, B port: ø12) 4 x M5 mounting hole

(17.9)
Digital input unit

Input connector Valve plate (Fitting for the type with P/E
ports on the U and/or D sides)
Output connector SI unit
Digital output unit Connector for One-touch fitting
handheld terminal [4(A), 2(B) port]
(Station 1) (Station n) Applicable tube O.D.: ø6, ø1/4"
One-touch fitting : ø8, ø5/16"
: ø10, ø3/8"
[1(P), 3/5(E) port] : ø12
Applicable tube O.D.: ø12, ø1/2"
11.5

2
8

82.7
1 P 1 P
2 B2 B2 B2 B2 B
(56.6)

56.6
13.2

8.7
3/5 E 3/5 E

35.2
31.6
4 A4 A4 A4 A4 A

11.1
14.2
(Pitch)
(For DIN rail

(10)

(21.7)
mounting)
(14.3)

25 20.5 P = 19

L1 = 19 x n1 + 166.2 + 47 x n2 Note 1) These figures show the “SS5Y7-10S6Q32-05D-C10”.


L2 = 19 x n1 + 56 Note 2) Refer to page 183 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
L4 = L3 – 10.5 Note 3) Refer to page 188 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 47 x n2 + 81.7
n1: Valve stations
n2: I/O unit stations

L3: DIN Rail Overall Length


Valve
I/O stations
unit (n1) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 235.5 248 273 285.5 310.5 323 348 360.5 385.5 410.5 423 448 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5 648
1 285.5 298 323 335.5 360.5 373 398 410.5 435.5 448 473 485.5 510.5 523 548 560.5 585.5 598 623 635.5 660.5 685.5 698
2 323 348 360.5 385.5 398 423 435.5 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5 648 673 685.5 710.5 723 748
3 373 398 410.5 435.5 448 473 485.5 510.5 523 548 560.5 585.5 598 623 635.5 660.5 673 698 710.5 735.5 760.5 773 798
4 423 435.5 460.5 473 498 510.5 535.5 560.5 573 598 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5 798 823 835.5
5 473 485.5 510.5 523 548 560.5 585.5 598 623 635.5 660.5 673 698 710.5 735.5 748 773 785.5 810.5 835.5 848 873 885.5
6 510.5 535.5 548 573 585.5 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5 798 823 835.5 860.5 873 898 910.5 935.5
7 560.5 585.5 598 623 635.5 660.5 673 698 710.5 735.5 748 773 785.5 810.5 823 848 860.5 885.5 910.5 923 948 960.5 985.5
8 610.5 623 648 660.5 685.5 710.5 723 748 760.5 785.5 798 823 835.5 860.5 873 898 910.5 935.5 948 973 985.5 — —
9 660.5 673 698 710.5 735.5 748 773 785.5 810.5 823 848 860.5 885.5 898 923 935.5 960.5 985.5 — — — — —

145
146
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Plug-in Connector Connecting Base
RoHS
EX600

Series SY3000/5000/7000
Type 12
Top Ported
How to Order Manifold

SS5Y 3 12S6 Q 2 05 U
Refer to pages 186 to 188 for
dimensions of Type 12/Top
ported type.        
 Series  SI unit output polarity, end plate type  Valve stations
3 SY3000 Power supply Power supply Symbol Stations Note
SI unit output polarity with M12 with 7/8 inch
5 SY5000 connector connector 02 2 stations
7 SY7000 Without SI unit Nil Double wiring Note 1)

···

···
SI unit positive common 2 3 16 16 stations
 SI unit SI unit negative common 4 5 02 2 stations
Specified layout Note 2)
Note 1) Without SI unit, the symbol is nil.

···

···
0 Without SI unit (Available up to 32 solenoids)
Note 2) Ensure a match with the common 24 24 stations
Q DeviceNet™ specification of the valve to be used. Note 1) Double wiring: 2-position single, double,
N PROFIBUS DP
3-position and 4-position valves can be used on
V CC-Link  I/O unit stations all manifold stations.
ZE EtherNet/IP™ Nil None Use of a 2-position single solenoid will result in
D EtherCAT 1 1 stations an unused control signal. If this is not desired,
F PROFINET order with a specified layout.
···

···

Note 2) Specified layout: Indicate the wiring


Note 1) I/O unit cannot be mounted without SI 9 9 stations
specifications on the manifold specification
unit. Note 1) Without SI unit, the symbol is nil. sheet. (Note that 2-position double, 3-position
Note 2) Valve plate which connects manifold and Note 2) SI unit is not included in I/O unit stations. and 4-position valves cannot be used where
SI unit is not mounted to a valve without SI Note 3) When I/O unit is selected, it is shipped single wiring has been specified.)
unit. Refer to the EX600 catalog separately, and assembled by users. Refer Note 3) This also includes the number of blanking plate
(CAT.E02-24) for mounting. to the attached operation manual for assembly.
mounting.
 P, E port entry, SUP/EXH block assembly
Internal pilot,
P, E port entry Internal pilot External pilot
Built-in silencer
U side (2 to 10 stations) U C Note) G
How to Order Manifold Assembly D side (2 to 10 stations) D E Note) H
Both sides (2 to 24 stations) B — J
∗ For built-in silencer type, P and E ports are available on U and D sides.
Example (SS5Y3-12S6-) 3/5(E) port is plugged. The silencer exhaust port is located on the opposite
side of P, E port entry. (Example: When the P, E port entry is D side, the
Digital input unit Digital output unit 2-position single silencer exhaust port is U side.)
EX600-DXPD EX600-DYPB SY3130-5U1-C6 (3 sets) ∗ When the built-in silencer type is used, keep the exhaust port from coming in
End plate Note) SI unit Note) 2-position double direct contact with water or other liquids.
EX600-ED2 EX600-SDN1 SY3230-5U1-C6 (2 sets) Note) For SUP/EXH block assembly specifications, built-in silencer types will
have P port entry stipulated.

 P, E port size (One-touch fittings)


0 1

PE PE
X X
3/5E B A B A B A B A B A 3/5E

SY3000 SY5000 SY7000


2 3
Symbol
4A 4A 4A 4A 4A

D side U side
PWR
OUT
0 1
4 5
2 3
PCI
1P
2B 2B 2B 2B 2B
1P Nil ø8 ø10 ø12
BUS BUS
IN OUT

8 7
N ø5/16" ø3/8" ø1/2"

1 2 3 4 5 Valve stations ∗ For N, sizes are in inches.


1 2 I/O unit stations  Mounting
Nil Direct mounting
SS5Y3-12S6Q42-05B ··········1 set (Type 12 5-station manifold base part no.) D DIN rail mounting (With DIN rail)
∗SY3130-5U1-C6 ·················3 sets (2-position single part no.)
D0 DIN rail mounting (Without DIN rail)
∗SY3230-5U1-C6 ················2 sets (2-position double part no.)
D3 For 3 stations
Specify a longer rail
∗EX600-DXPD ······················1 set I/O unit part number (Station 1)
···

···

∗EX600-DYPB ······················1 set I/O unit part number (Station 2) than the standard length.
D24 For 24 stations
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc. Note 1) When it is necessary to mount a DIN rail without an SI unit, select D0
and order DIN rail length separately, referring to L3 in the dimensions.
• The valve arrangement is numbered as the 1st station from the D side. (Refer to page 225 for part numbers of DIN rail.)
• Under the manifold part number, state the valves to be mounted, then the Note 2) Refer to page 247 for the fixation of DIN rail mounting type manifold.
I/O units in order from the 1st station as shown in the figure above.
For details about the EX600 Integrated-type (For Input/Output) Serial
If the arrangement becomes complicated, specify on a manifold Transmission System, refer to the WEB catalog or the Best Pneumatics No. 1
specification sheet. and the Operation Manual. For details about part numbers of SI units to be
Note) Do not enter the SI unit part number and the end plate part number mounted, refer to pages 213 and 214 in this catalog. (IP40 specifications may be
together. required according to the I/O unit to be selected.) Please download the Operation
Manual via SMC website, http://www.smcworld.com

147
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
            

Plug-in
Top ported

 Series  Pilot valve option  A, B port size


3 SY3000 Nil Standard (102 psi (0.7 MPa)) Thread piping
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Symbol Port size Applicable series
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa)) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000

Metal Base
pressure type. 02 1/4 SY7000

 Type of actuation  Coil type


One-touch fitting (Metric)
1 Single
Symbol A, B port SY3000 SY5000 SY7000
2-position Nil Standard C2 ø2  — —
2 Double

Plug-in
T With power saving circuit (Continuous duty type) C3 ø3.2  — —
3 Closed center
∗ Be sure to select the power saving circuit type C4 ø4   —
4 3-position Exhaust center when the valve is continuously energized for C6 ø6   
5 Pressure center long periods of time. C8 ø8 —
A∗ N.C./N.C. ∗ Be careful of the energizing time when the
 
4-position C10 ø10 — —
B∗ dual 3-port N.O./N.O. power saving circuit is selected. Refer to page 
C12

Manifold Exploded View


ø12 — —
C∗ N.C./N.O. 244 for details. 

Type 50, 51, 52


∗ Only rubber seal type is available for the One-touch fitting (Inch)
4-position dual 3-port valve.  Rated voltage Symbol A, B port SY3000 SY5000 SY7000
5 24 VDC N1 ø1/8"  — —
N3 ø5/32"   —
N7 ø1/4"   
 Seal type N9 ø5/16" —  
0 Rubber seal
 Light/surge voltage suppressor N11 ø3/8" — — 
1 Metal seal
and common specification

Connector Connecting Base


Surge voltage Common
Symbol With light
suppressor specification
R —
Non-polar  Thread type
 Pilot type U 
Nil Rc
Nil Internal pilot S — Positive F G

Z  common
R External pilot N NPT
NS — Negative T NPTF
NZ  common
∗ Only Nil is available for M5.
∗ Select a valve from R, U, S or Z when the SI unit

Plug-in
 Back pressure check valve polarity is positive common. Select a valve from
R, U, NS or NZ when the SI unit output polarity
Nil None is negative common.
H Built-in ∗ Only “Z” and “NZ” types are available for with  Type of mounting screw

Manifold Exploded View


∗ Only rubber seal type. Manifold installed type is the power saving circuit. Nil Round head combination screw

Type 10, 11, 12


available if the back pressure check valve is B Hexagon socket head cap screw
required for a valve with metal seal. Refer to Round head combination screw
page 232 for Ordering Example. However, it is  Manual override K (Falling-out-prevention type)
not recommended to use the built-in valve type
Nil: D: Hexagon socket head cap screw
and the manifold installed type at the same time
Non-locking Push-turn H (Falling-out-prevention type)
because it will reduce the flow.
push type locking slotted
∗ The built-in valve type back pressure check ∗ For “K” and “H”, the valve body cover has a drop
type
valve is not available for the 3-position type and prevention construction to stop the mounting
the SY7000. screws from falling out when the valve is
Plug Assembly Part No.

removed for maintenance etc.


One-touch Fittings/

∗ When ordering a valve individually, the base


gasket is not included. Since the base gasket is
E: F: attached to the manifold, please order the base
Push-turn Slide locking gasket separately if it is needed for maintenance
locking lever type service.
type Refer to page 220 for part numbers of the base
gasket and mounting screw.
Manifold Options

∗ "B" and "H" cannot be selected for the individual


SUP/EXH spacer assembly or interface
regulator.

∗ Refer to page 14 for with the safety slide locking Protective class
manual override. class III (Mark: )
148
Type 10 Plug-in Connector Connecting Base
Side Ported
EX250

Series SY3000/5000/7000
Type 11
Bottom Ported

How to Order Manifold

Refer to pages 184 (SY5000) and


SS5Y 3 10 S Q 05 U C6
185 (SY7000) for dimensions of
Type 11/Bottom ported type.         
 Series  SI unit  Input block type
3 SY3000 0 Without SI unit PNP input NPN input
5 SY5000 Q DeviceNet™ (Negative common) (Positive common) (Negative common)
7 SY7000 N PROFIBUS DP (Negative common) Without input block Nil
V CC-Link (Positive common) M12, 2 inputs A D
 Type TA 2 power 8 in/8 out, 31 slave modes
supply
M12, 4 inputs B E
TB AS-Interface systems 4 in/4 out, 31 slave modes M8, 4 inputs C F
10 Side ported (Negative 1 power
11 Bottom ported∗ TC common) supply 8 in/8 out, 31 slave modes Note) Without SI unit, the symbol is nil.
∗ The SY5000 manifold base is used for the
TD systems 4 in/4 out, 31 slave modes
bottom ported of the SY3000. When ordering, Y CANopen (Negative common)  Valve stations
refer to “Plug-in Mixed Mounting Type Manifold” ZE EtherNet/IP™ (Negative common) Symbol Stations Note
(from page 189). Note 1) Ensure a match with the common specification 02 2 stations
of the valve to be used. Double wiring Note 1)
 Input block stations

···

···
Note 2) Input block cannot be mounted without SI unit. 16 16 stations
Nil None Note 3) The supply current from the SI unit of 02 2 stations
1 1 station AS-Interface applicable 1 power supply Specified layout Note 2)

···

···
system specification to the input block and (Available up to 32 solenoids)
···

···

valve is limited. 24 24 stations


8 8 stations Note 1) Double wiring: 2-position single, double,
Note) Without SI unit, the symbol is nil. The 3-position and 4-position valves can be used
maximum number of stations is limited for on all manifold stations.
the AS-Interface applicable SI unit. Use of a 2-position single solenoid will result
in an unused control signal. If this is not
desired, order with a specified layout.
How to Order Manifold Assembly Note 2) Specified layout: Indicate the wiring
specifications on the manifold specification
sheet. (Note that 2-position double, 3-position
and 4-position valves cannot be used where
Example (SS5Y3-10S-) 3-position closed single wiring has been specified.)
2-position double (24 VDC) center (24 VDC) When determining the number of valve
SY3300-5U1 (1 set) stations, note that the maximum number of
SY3200-5U1 (1 set) solenoids for the AS-Interface applicable SI
unit specification is as follows.
• 8 in/8 out specification: Max. 8 solenoids
2-position single (24 VDC) • 4 in/4 out specification: Max. 4 solenoids
SY3100-5U1 (3 sets) Note 3) This also includes the number of blanking
plate assembly.
Note 4) For the product without the SI unit (S0), note
ide
Us the maximum number of solenoids of the SI
unit that will be mounted. If the layout is
s
n

specified, indicate it on the manifold


tio
ta
S

specification sheet.
23
1
e
sid
D  P, E port entry, SUP/EXH block assembly
Manifold base (5 stations) Internal pilot,
SS5Y3-10SQ1C-05D-C6 P, E port entry Internal pilot External pilot
Built-in silencer

SS5Y3-10SQ1C-05D-C6 ···1 set (Type 10 5-station manifold base part no.)


U side (2 to 10 stations) U C G
∗SY3100-5U1 ······················3 sets (2-position single part no.) D side (2 to 10 stations) D E H
∗SY3200-5U1 ······················1 set (2-position double part no.) Both sides (2 to 24 stations) B F J
∗SY3300-5U1 ······················1 set (3-position closed center part no.) ∗ 3/5(E) port is plugged for the built-in silencer type.
The asterisk denotes the symbol for assembly.
∗ When the built-in silencer type is used, keep the exhaust port from coming in
Prefix it to the part numbers of the valve etc. direct contact with water or other liquids.

• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement For details about the EX250 Integrated-type (For Input/Output) Serial
becomes complicated, specify on a manifold specification sheet. Transmission System, refer to the WEB catalog or the Best Pneumatics
No. 1 and the Operation Manual. For details about part numbers of SI units
Note) When mixing top ported configurations, select from page 156. to be mounted, refer to page 215 in this catalog. Please download the
In this case, use caution as there is also output on the A and B port on base side. Operation Manual via SMC website, http://www.smcworld.com
Specify on a manifold specification sheet if plugs are required on the A and B port
on base side.
149
Valve
 A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)

Sub-plate
Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2  — — — — N1 ø1/8"  — — — —

Plug-in
C3 ø3.2  — — — — N3 ø5/32"   —  —

Straight
C4 ø4   —  — N7 ø1/4"     
Straight

C6 ø6      N9 ø5/16" —    
C8 ø8 —     N11 ø3/8" — —  — 
C10 ø10 — —  —  CM∗ Straight port, mixed sizes     
C12 ø12 — —  —  LN3 ø5/32"  — — — —
CM∗

Upward
Straight port, mixed sizes      LN7 ø1/4"   — — —

Metal Base
L4 ø4   — — — LN9 ø5/16" —  — — —
L6 ø6    — — LN11 ø3/8" — —  — —
Upward

Elbow Note)
L8 ø8 —   — — BN3 ø5/32"  — — — —

Downward
L10 ø10 — —  — — BN7 ø1/4"   — — —

Plug-in
L12 ø12 — —  — — BN9 ø5/16" —  — — —
Elbow Note)

B4 ø4   — — — BN11 ø3/8" — —  — —
Downward

B6 ø6    — — Elbow port, mixed sizes


LM∗ (Including upward and    — —
B8 ø8 —   — — downward piping)

B10 ø10 — —  — — P, E port size

Manifold Exploded View


ø5/16" ø3/8" ø1/2" ø3/8" ø1/2"
B12 ø12 — —  — — (One-touch fittings)

Type 50, 51, 52


Elbow port, mixed sizes
LM∗ (Including upward and    — —
downward piping)

P, E port size
ø8 ø10 ø12 ø10 ø12
(One-touch fittings)
Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 226 to 228).
∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting direction.

Connector Connecting Base


 Mounting and Option
Option DIN Rail Option
Symbol Mounting
Name plate Station number Nil Direct mounting
Nil — — 0 Without DIN rail (with bracket)
Direct 3 For 3 stations Specify a longer
AA mounting
 
rail than the total
BA
···

···

 — length of specified

Plug-in
D — — 24 For 24 stations stations.
DIN rail
A mounting  
B  —

Manifold Exploded View


Type 10, 11, 12
Note 1) Enter the number of stations inside  when it is larger than the
number of valve stations. (Refer to “DIN Rail Option” above.)
Note 2) Only direct mounting is available for Type 11 (Bottom ported).
Note 3) Refer to page 247 for the fixation of DIN rail mounting type manifold.
∗ When it is necessary to mount a DIN rail without an SI unit, select D0 and
order DIN rail length separately, referring to L3 in the dimensions. (Refer to
page 225 for part numbers of DIN rail.)
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

Protective class
class III (Mark: )

150
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 0 0 5 1
          
Base mounted

 Series  Pilot valve option  Manual override


3 SY3000 Nil Standard (102 psi (0.7 MPa)) Nil: D:
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Non-locking Push-turn
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa)) push type locking
∗ Only metal seal type is available for the high slotted
pressure type. type

 Type of actuation
1 Single  Coil type
2-position E: F:
2 Double Nil Standard Push-turn Slide locking
3 Closed center T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust center ∗ Be sure to select the power saving circuit type lever
5 Pressure center when the valve is continuously energized for type
A∗ N.C./N.C. long periods of time.
4-position ∗ Be careful of the energizing time when the
B∗ dual 3-port
N.O./N.O.
power saving circuit is selected. Refer to page
C∗ N.C./N.O.
244 for details. ∗ Refer to page 14 for with the safety slide locking
∗ Only rubber seal type is available for the manual override.
4-position dual 3-port valve.
 Rated voltage
5 24 VDC  Type of mounting screw
 Seal type Nil Round head combination screw
0 Rubber seal B Hexagon socket head cap screw
1 Metal seal  Light/surge voltage suppressor K
Round head combination screw
and common specification (Falling-out-prevention type)
Surge voltage Common H Hexagon socket head cap screw
Symbol With light (Falling-out-prevention type)
 Pilot type suppressor specification
R — ∗ For “K” and “H”, the valve body cover has a drop
Nil Internal pilot Non-polar prevention construction to stop the mounting
U 
R External pilot screws from falling out when the valve is
S — Positive removed for maintenance etc.

Z  common ∗ When ordering a valve individually, the base
NS — Negative gasket is not included. Since the base gasket is
 Back pressure check valve NZ  common attached to the manifold, please order the base
gasket separately if it is needed for maintenance
(Built-in valve type) ∗ “R" and “U” are applicable for every SI unit. service.
Nil None However, “S” and “Z” can be used only for Refer to page 220 for part numbers of the base
H Built-in CC-Link applicable unit and “NS” and “NZ” are gasket and mounting screw.
for units which are not CC-Link applicable. ∗ "B" and "H" cannot be selected for the individual
∗ Only rubber seal type. Manifold installed type is ∗ Only “Z” and “NZ” types are available for with
available if the back pressure check valve is SUP/EXH spacer assembly, interface regulator
the power saving circuit. or double check spacer assembly with residual
required for a valve with metal seal. Refer to
page 232 for Ordering Example. However, it is pressure release valve.
not recommended to use the built-in valve type
and the manifold installed type at the same time
because it will reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type and
the SY7000.

Protective class
class # (Mark: )
151
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY3000 Connector Connecting Base EX250

C2
U
SS5Y3-10S- Stations D - C3,
C4, N3 (D)
N1

Sub-plate
B C6, N7
D side U side
(L5) L1 Manual override Note 2)

DIN rail holding screw 18 21 63 (Push-turn locking slotted type:


Press, then rotate it. )

Plug-in
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor)
: Gray (For metal seal)
DIN rail holding screw
DIN rail 2(B) port side : Yellow
(For DIN rail mounting)

(5.5)
(8)
B A B A B A B A B A

(35)

92.6
14 A 14 A 14 A 14 A 14 A

83

Metal Base
0

1
66

60.5
2

(40.9)
3
12 B 12 B 12 B 12 B 12 B

4.6

Plug-in
4.6
2.7

1.7
)
(4.9)
SI unit

C6: 3.6
N7: 7.4
7.5

2 x M4 mounting hole Input block 4 x M4 mounting hole

(
(Fitting for the type with P/E
5.5 L6 L2 1.5 ports on the U and/or D sides)
(5.3) (L4)

Manifold Exploded View


(DIN rail mounting hole pitch: 12.5)

Type 50, 51, 52


(L3)
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø2
One-touch fitting : ø3.2, ø1/8"
[1(P), 3/5(E) port] (Station 1) --- (Station n)
: ø4, ø5/32"
Applicable tube O.D.: ø8, ø5/16" : ø6, ø1/4"

Connector Connecting Base


1 P 1 P
0
BUS

63.1
1
10.6

13.6

56.6
60

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

2
PWR 4 A4 A4 A4 A4 A
21.6

3
18

13.2

(For DIN rail


mounting)
(Pitch)
(7.5)

M3
(11.8)

4 x M8 18.3 15.5 P = 10.5 (17.8)


2 x M12

Plug-in
3-pin socket

L1 = 10.5 x n1 + 135.5 + 21 x n2 Note 1) These figures show the “SS5Y3-10SQ1A-05D-C6”.

Manifold Exploded View


L2 = 10.5 x n1 + 42 Note 2) Refer to page 181 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.

Type 10, 11, 12


L4 = L3 – 10.5 Note 3) Refer to page 186 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 21 x n2 + 82
n1: Valve stations
n2: Input block stations
L3: DIN Rail Overall Length
Valve
stations
(n1)
Plug Assembly Part No.

Input 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
One-touch Fittings/

block
stations (n2)
0 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423
1 210.5 223 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5
2 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5
3 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5
Manifold Options

4 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498
5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523
6 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548
7 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548 548 560.5
8 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548 548 560.5 573 585.5

152
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base EX250

U C4, N3
SS5Y5-10S- Stations D - C6, N7 (D)
B C8, N9
D side U side
(L5) L1
Manual override Note 2)
18 21 63
DIN rail holding screw
(For DIN rail mounting)
(Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
DIN rail holding screw (Light/surge voltage suppressor) : Gray (For metal seal)
(For DIN rail mounting) 2(B) port side : Yellow
Input block
DIN rail SI unit

(5.5)
(8)
BA BA BA BA BA

(35)
14 A 14 A 14 A 14 A 14 A
0

97.5

113.4
1
66

81.2
3

(61.7)
5.5
12 B 12 B 12 B 12 B 12 B
23.5

10.9
4.7
(5.9)
2 x M4 mounting hole
(8.3)

4 x M5 mounting hole
5.5 L6 L2 1.5 (Fitting for the type with P/E
ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)
One-touch fitting
[4(A), 2(B) port]
(Station 1) ----------- (Station n) Applicable tube O.D.: ø4, ø5/32"
One-touch fitting : ø6, ø1/4"
[1(P), 3/5(E) port] : ø8, ø5/16"
Applicable tube O.D.: ø10, ø3/8"

0
BUS 1 P 1 P

73.2
1 2 B2 B2 B2 B2 B

56.6
60

12.4

13.2

2
3/5 E 3/5 E
33.4

29.1

PWR
3
4 A4 A4 A4 A4 A
14.1
8.7
(For DIN rail

(7.5)
mounting)

M3 (Pitch)
(11.8)

20 18 P = 16 (20.5)
4 x M8 2 x M12
3-pin socket

L1 = 16 x n1 + 141.5 + 21 x n2 Note 1) These figures show the “SS5Y5-10SQ1A-05D-C8”.


L2 = 16 x n1 + 48 Note 2) Refer to page 182 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
L4 = L3 – 10.5 Note 3) Refer to page 187 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 21 x n2 + 81.5
n1: Valve stations
n2: Input block stations
L3: DIN Rail Overall Length
Valve
stations
(n1) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Input
block
stations (n2)
0 198 223 235.5 248 273 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 560.5
1 223 235.5 260.5 273 285.5 298 323 335.5 348 373 385.5 398 410.5 435.5 448 460.5 485.5 498 510.5 523 548 560.5 573
2 248 260.5 273 298 310.5 323 335.5 360.5 373 385.5 410.5 423 435.5 448 473 485.5 498 523 535.5 548 560.5 585.5 598
3 260.5 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 623
4 285.5 298 323 335.5 348 373 385.5 398 410.5 435.5 448 460.5 473 498 510.5 523 548 560.5 573 585.5 610.5 623 635.5
5 310.5 323 335.5 360.5 373 385.5 398 423 435.5 448 473 485.5 498 510.5 535.5 548 560.5 585.5 598 610.5 623 648 660.5
6 323 348 360.5 373 398 410.5 423 435.5 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 623 635.5 648 660.5 685.5
7 348 360.5 385.5 398 410.5 435.5 448 460.5 473 498 510.5 523 548 560.5 573 585.5 610.5 623 635.5 648 673 685.5 698
8 373 385.5 398 423 435.5 448 473 485.5 498 510.5 535.5 548 560.5 573 598 610.5 623 648 660.5 673 685.5 710.5 723

153
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY7000 Connector Connecting Base EX250

C6, N7
U
SS5Y7-10S- Stations D - C8,
C10, N11 (D)
N9

Sub-plate
B C12
U side
D side (L5) Manual override Note 2)
L1
18 21 63 DIN rail holding screw
(For DIN rail mounting)
(
Push-turn locking slotted type:
Press, then rotate it. )
DIN rail holding screw

Plug-in
4(A) port side : Blue (For rubber seal)
(For DIN rail mounting) (Light/surge voltage suppressor) : Gray (For metal seal)
Input 2(B) port side : Yellow
connector
SI unit
(8) (DIN rail)

B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A
0

1
66

128.8
115

Metal Base
2

(5.5)

96.7
(77.1)
12 B 12 B 12 B 12 B 12 B

5.5
38.9

Plug-in
8.8
3.9
2 x M4 mounting hole (6)
(9.3)

(A, B port: ø12) 4 x M5 mounting hole


(17.9)
(Fitting for the type with P/E
5.5 L6 L2 1.5

Manifold Exploded View


ports on the U and/or D sides)

Type 50, 51, 52


(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)
One-touch fitting
[4(A), 2(B) port ]
(Station 1) (Station n) Applicable tube O.D.: ø6, ø1/4"
One-touch fitting : ø8, ø5/16"
[1(P), 3/5(E) port] : ø10, ø3/8"
Applicable tube O.D.: ø12, ø1/2" : ø12

Connector Connecting Base


2
0

82.7
1 P 1 P
BUS 2 B2 B2 B2 B2 B
1

56.6
60

13.2
14.2

2 3/5 E 3/5 E
11.1
35.2

8.7

4 A4 A4 A4 A4 A
31.6
PWR
3
(For DIN rail

(Pitch)
(10)

M3

Plug-in
mounting)

25 20.5 P = 19 (21.7)
2 x M12
(14.3)

4 x M8
3-pin socket

Manifold Exploded View


Type 10, 11, 12
L1 = 19 x n1 + 149.7 + 21 x n2 Note 1) These figures show the “SS5Y7-10SQ1A-05D-C10”.
L2 = 19 x n1 + 56 Note 2) Refer to page 183 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
L4 = L3 – 10.5 Note 3) Refer to page 188 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 21 x n2 + 81.7
n1: Valve stations
n2: Input block stations

L3: DIN Rail Overall Length


Plug Assembly Part No.

Valve
One-touch Fittings/

stations
(n1) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
I/O unit
stations (n2)
0 223 235.5 260.5 273 298 310.5 335.5 348 373 385.5 410.5 423 448 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5
1 235.5 260.5 273 298 310.5 335.5 348 373 385.5 410.5 423 448 460.5 485.5 498 523 548 560.5 585.5 598 623 635.5 660.5
2 260.5 273 298 310.5 335.5 348 373 398 410.5 435.5 448 473 485.5 510.5 523 548 560.5 585.5 598 623 635.5 660.5 673
Manifold Options

3 285.5 298 323 335.5 360.5 373 398 410.5 435.5 448 473 485.5 510.5 523 548 560.5 585.5 598 623 635.5 660.5 673 698
4 298 323 335.5 360.5 373 398 410.5 435.5 448 473 485.5 510.5 523 548 573 585.5 610.5 623 648 660.5 685.5 698 723
5 323 335.5 360.5 373 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5 610.5 623 648 660.5 685.5 698 723 735.5
6 348 360.5 385.5 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5 610.5 623 648 660.5 685.5 698 723 748 760.5
7 360.5 385.5 398 423 435.5 460.5 473 498 510.5 535.5 548 573 598 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5
8 385.5 398 423 448 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5 798

154
Plug-in Connector Connecting Base
EX250

Series SY3000/5000/7000
Type 12
Top Ported

How to Order Manifold

SS5Y 3 12S Q 05 U
Refer to pages 186 to 188 for
dimensions of Type 12/Top
ported type.        
 Series  SI unit  Valve stations
3 SY3000 0 Without SI unit Symbol Stations Note
5 SY5000 Q DeviceNet™ (Negative common) 02 2 stations
7 SY7000 N PROFIBUS DP (Negative common) Double wiring Note 1)

···

···
V CC-Link (Positive common) 16 16 stations
 Input block stations TA 2 power 8 in/8 out, 31 slave modes
AS-Interface supply 4 in/4 out, 31 slave modes
02 2 stations
Specified layout Note 2)
TB

···

···
systems
Nil None (Negative 1 power (Available up to 32 solenoids)
1 1 station
TC common) supply 8 in/8 out, 31 slave modes 24 24 stations
TD systems 4 in/4 out, 31 slave modes Note 1) Double wiring: 2-position single, double, 3-position
···

···

8 8 stations
Y CANopen (Negative common) and 4-position valves can be used on all manifold
stations.
ZE EtherNet/IP™ (Negative common) Use of a 2-position single solenoid will result in an
Note) Without SI unit, the symbol is nil. The
maximum number of stations is limited for Note 1) Ensure a match with the common specification unused control signal. If this is not desired, order with
a specified layout.
the AS-Interface applicable SI unit. of the valve to be used. Note 2) Specified layout: Indicate the wiring specifications on
Note 2) Input block cannot be mounted without SI unit. the manifold specification sheet. (Note that 2-position
Note 3) The supply current from the SI unit of
 Input block type AS-Interface applicable 1 power supply system
double, 3-position and 4-position valves cannot be
used where single wiring has been specified.)
PNP input NPN input specification to the input block and valve is When determining the number of valve stations, note
limited. that the maximum number of solenoids for the
(Positive common) (Negative common)
AS-Interface applicable SI unit specification is as
Without input block Nil follows.
M12, 2 inputs A D • 8 in/8 out specification: Max. 8 solenoids
• 4 in/4 out specification: Max. 4 solenoids
M12, 4 inputs B E Note 3) This also includes the number of blanking plate
M8, 4 inputs C F assembly.
Note 4) For the product without the SI unit (S0), note the
Note) Without SI unit, the symbol is nil. maximum number of solenoids of the SI unit that will
be mounted. If the layout is specified, indicate it on
the manifold specification sheet.
How to Order Manifold Assembly  P, E port entry, SUP/EXH block assembly
Internal pilot,
P, E port entry Internal pilot External pilot
Built-in silencer
Example (SS5Y3-12S-) U side (2 to 10 stations) U C Note) G
3-position closed
center (24 VDC) D side (2 to 10 stations) D E Note) H
2-position double (24 VDC)
SY3330-5U1-C6 (1 set) Both sides (2 to 24 stations) B — J
SY3230-5U1-C6 (1 set)
∗ For built-in silencer type, P and E ports are available on U and D sides. 3/5(E) port is plugged.
2-position single (24 VDC) The silencer exhaust port is located on the opposite side of P, E port entry. (Example: When the
SY3130-5U1-C6 (3 sets) P, E port entry is D side, the silencer exhaust port is U side.)
∗ When the built-in silencer type is used, keep the exhaust port from coming in direct contact with
water or other liquids.
Note) For SUP/EXH block assembly specifications, built-in silencer types will have P port entry
stipulated.
ide
Us  P, E port size (One-touch fittings)
s
n
tio
ta

Symbol SY3000 SY5000 SY7000


S

2 3
1 Nil ø8 ø10 ø12
ide
Ds
N ø5/16" ø3/8" ø1/2"
Manifold base (5 stations) ∗ For N, sizes are in inches.
SS5Y3-12SQ1C-05D
 Mounting Note 1) If the DIN rail must be mounted
SS5Y3-12SQ1C-05D ···1 set (Type 12 5-station manifold base part no.)
Nil Direct mounting without an SI unit, select D0. Then,
D DIN rail mounting (With DIN rail) refer to L3 of the dimensions for the
∗SY3130-5U1-C6 ···········3 sets (2-position single part no.) DIN rail length and order separately.
∗SY3230-5U1-C6 ···········1 set (2-position double part no.) D0 DIN rail mounting (Without DIN rail) (Refer to page 225 for the DIN rail
∗SY3330-5U1-C6 ···········1 set (3-position closed center part no.) D3 For 3 stations Specify a longer part number.)
rail than the Note 2) Refer to page 247 for the fixation of
···

···

The asterisk denotes the symbol for assembly. DIN rail mounting type manifold.
Prefix it to the part numbers of the valve etc. D24 For 24 stations standard length.

• The valve arrangement is numbered as the 1st station from the D side. For details about the EX250 Integrated-type (For Input/Output) Serial
• Under the manifold part number, state the valves to be mounted in order Transmission System, refer to the WEB catalog or the Best Pneumatics No. 1
from the 1st station as shown in the figure above. If the arrangement and the Operation Manual. For details about part numbers of SI units to be
becomes complicated, specify on a manifold specification sheet. mounted, refer to page 215 in this catalog. Please download the Operation Manual
via SMC website, http://www.smcworld.com

155
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
            

Plug-in
Top ported

 Series  Pilot valve option  A, B port size


3 SY3000 Nil Standard (102 psi (0.7 MPa)) Thread piping
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Symbol Port size Applicable series
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa)) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000

Metal Base
pressure type. 02 1/4 SY7000
 Type of actuation One-touch fitting (Metric)
1 Single  Coil type Symbol A, B port SY3000 SY5000 SY7000
2-position C2
2 Double Nil Standard ø2  — —

Plug-in
3 Closed center T With power saving circuit (Continuous duty type) C3 ø3.2  — —
4 3-position Exhaust center ∗ Be sure to select the power saving circuit type C4 ø4   —
5 Pressure center when the valve is continuously energized for C6 ø6   
A∗ N.C./N.C. long periods of time. C8 ø8 —  
4-position ∗ Be careful of the energizing time when the
B∗ dual 3-port
N.O./N.O. C10 ø10 — — 
power saving circuit is selected. Refer to page
C∗ C12

Manifold Exploded View


N.C./N.O. ø12 — — 
244 for details.

Type 50, 51, 52


∗ Only rubber seal type is available for the One-touch fitting (Inch)
4-position dual 3-port valve.  Rated voltage Symbol A, B port SY3000 SY5000 SY7000
5 24 VDC N1 ø1/8"  — —
N3 ø5/32"   —
 Seal type N7 ø1/4"   
N9 ø5/16" —  
0 Metal seal  Light/surge voltage suppressor N11 ø3/8" — — 
1 Rubber seal and common specification

Connector Connecting Base


Surge voltage Common
Symbol With light
suppressor specification
 Pilot type R —
Non-polar
 Thread type
U  Nil Rc
Nil Rubber seal
S — Positive F G
R Metal seal
Z

common
 N NPT
NS — Negative T NPTF
NZ  common ∗ Only Nil is available for M5.
 Back pressure check valve ∗ “R" and “U” are applicable for every SI unit.

Plug-in
(Built-in valve type) However, “S” and “Z” can be used only for
CC-Link applicable unit and “NS” and “NZ” are
Nil None for units which are not CC-Link applicable.  Type of mounting screw
H Built-in ∗ Only “Z” and “NZ” types are available for with

Manifold Exploded View


Nil Round head combination screw
∗ Only rubber seal type. Manifold installed type is the power saving circuit.

Type 10, 11, 12


available if the back pressure check valve is B Hexagon socket head cap screw
required for a valve with metal seal. Refer to Round head combination screw
K (Falling-out-prevention type)
page 232 for Ordering Example. However, it is
not recommended to use the built-in valve type
 Manual override Hexagon socket head cap screw
and the manifold installed type at the same time Nil: D: H (Falling-out-prevention type)
because it will reduce the flow. Non-locking Push-turn
∗ For “K” and “H”, the valve body cover has a drop
∗ The built-in valve type back pressure check push type locking slotted
prevention construction to stop the mounting
valve is not available for the 3-position type and type
screws from falling out when the valve is
the SY7000.
removed for maintenance etc.
Plug Assembly Part No.
One-touch Fittings/

∗ When ordering a valve individually, the base


gasket is not included. Since the base gasket is
attached to the manifold, please order the base
E: F: gasket separately if it is needed for maintenance
Push-turn Slide locking service.
locking lever type Refer to page 220 for part numbers of the base
type gasket and mounting screw.
Manifold Options

∗ "B" and "H" cannot be selected for the individual


SUP/EXH spacer assembly or interface
regulator.

∗ Refer to page 14 for with the safety slide locking Protective class
manual override. class III (Mark: )
156
Type 10 Plug-in Connector Connecting Base
Side Ported
EX260

Series SY3000/5000/7000
Type 11
Bottom Ported

RoHS
How to Order Manifold

Refer to pages 184 (SY5000)


and 185 (SY7000) for
SS5Y 3 10 S NA N 05 U C6
dimensions of Type
11/Bottom ported type.         
 Series  Valve stations  P, E port entry
3 SY3000 In the case of the 32-output SI unit U U side (2 to 10 stations)
5 SY5000 Symbol Stations Note D D side (2 to 10 stations)
7 SY7000 02 2 stations B Both sides (2 to 24 stations)
Double wiring Note 1)
···

···

 Type 16 16 stations
02 2 stations  SUP/EXH block assembly
10 Side ported Specified layout Note 2) Nil Internal pilot
···

···

11 Bottom ported∗ (Available up to 32 solenoids)


24 24 stations S Internal pilot, Built-in silencer
∗ The SY5000 manifold base is used for the R External pilot
bottom ported of the SY3000. When ordering, In the case of the 16-output SI unit
refer to “Plug-in Mixed Type Manifold” (from Symbol Stations Note ∗ 3/5(E) port is plugged for the built-in silencer
page 189). type.
02 2 stations ∗ When the built-in silencer type is used, keep the
Double wiring Note 1)
···

···

exhaust port from coming in direct contact with


 SI unit specifications 08 8 stations water or other liquids.
02 2 stations
Number Communication Specified layout Note 2)
Symbol Protocol
···

···

of outputs connector (Available up to 16 solenoids)


0 Without SI unit 16 16 stations Refer to the page on the right for 
.

QA DeviceNet™ 32 Note 1) Double wiring: 2-position single, double,


M12 3-position and 4-position valves can be
QB 16
 Mounting and Option
NA 32 used on all manifold stations.
M12 Use of a 2-position single solenoid will Option
NB PROFIBUS 16 Symbol Mounting
result in an unused control signal. If this is Name plate Station number
NC DP 32
D-sub Note) not desired, order with a specified layout
ND 16
Note 2) Specified layout: Indicate the wiring
Nil — —
Direct
VA 32 specifications on the manifold specification AA mounting
 
CC-Link M12
VB 16 sheet. BA  —
DA 32 (Note that 2-position double, 3-position D — —
EtherCAT M12 DIN rail
DB 16 and 4-position valves cannot be used A  
FA 32 where single wiring has been specified.) mounting
PROFINET M12 B  —
FB 16 Note 3) This also includes the number of blanking
plate assembly. Note 1) Enter the number of stations inside 
EA 32
when it is larger than the number of valve
EtherNet/IP™ M12 Note 4) For the model without the SI unit (S0),
EB 16 stations. (Refer to “DIN Rail Option”
note the maximum number of solenoids of
Note) IP40 for the D-sub applicable below.)
the SI unit that will be mounted. If the
communication connector specification. Note 2) Only direct mounting is available for Type
layout is specified, indicate it on the
DIN rail cannot be mounted without SI unit. 11 (Bottom ported).
manifold specification sheet.
Note 3) Refer to page 247 for the fixation of DIN
rail mounting type manifold.

 SI unit output polarity DIN Rail Option


Nil Positive common (NPN) Nil Standard length
N Negative common (PNP) 0 Without DIN rail (with bracket)
Note 1) Ensure a match with the common 3 For 3 stations Specify a longer rail
than the total length of
···

···

specification of the valve to be used.


Note 2) Without SI unit, the symbol is nil. 24 For 24 stations specified stations.
∗ When it is necessary to mount a DIN rail without
an SI unit, select D0 and order DIN rail length
separately, referring to L3 in the dimensions.
(Refer to page 225 for part numbers of DIN rail.)

For details about the EX260 Integrated-type (For Output)


Serial Transmission System, refer to the WEB catalog or the
Best Pneumatics No. 1 and the Operation Manual. For details
about part numbers of SI units to be mounted, refer to page
216 in this catalog. Please download the Operation Manual via
SMC website, http://www.smcworld.com

157
Valve
Sub-plate
A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)

Plug-in
Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2  — — — — N1 ø1/8"  — — — —
C3 ø3.2  — — — — N3 ø5/32"   —  —

Straight
C4 ø4   —  — N7 ø1/4"     
Straight

C6 ø6      N9 ø5/16" —    
C8 N11

Metal Base
ø8 —     ø3/8" — —  — 
C10 ø10 — —  —  CM∗ Straight port, mixed sizes     
C12 ø12 — —  —  LN3 ø5/32"  — — — —
CM∗

Upward
Straight port, mixed sizes      LN7 ø1/4"   — — —
L4 ø4 — — — LN9 ø5/16" — — — —

Plug-in
  
L6 ø6    — — LN11 ø3/8" — —  — —
Upward

Elbow Note)
L8 ø8 —   — — BN3 ø5/32"  — — — —

Downward
L10 ø10 — —  — — BN7 ø1/4"   — — —
L12 ø12 — —  — — BN9 ø5/16" —  — — —
Elbow Note)

Manifold Exploded View


B4 ø4   — — — BN11 ø3/8" — —  — —

Type 50, 51, 52


Downward

B6 ø6    — — Elbow port, mixed sizes


LM∗ (Including upward and    — —
B8 ø8 —   — — downward piping)

B10 ø10 — —  — — P, E port size


ø5/16" ø3/8" ø1/2" ø3/8" ø1/2"
B12 ø12 — —  — — (One-touch fittings)
Elbow port, mixed sizes
LM∗ (Including upward and    — —
downward piping)

Connector Connecting Base


P, E port size
ø8 ø10 ø12 ø10 ø12
(One-touch fittings)

Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 226 to 228).
∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting direction.

How to Order Manifold Assembly

Plug-in
Manifold Exploded View
Example (SS5Y3-10SNAN-)

Type 10, 11, 12


SS5Y3-10SNAN-04D-C6···1 set (Type 10 4-station manifold base part no.)
2-position single (24 VDC) 2-position double (24 VDC) ∗SY3100-5U1·····················2 sets (2-position single part no.)
SY3100-5U1 (2 sets) SY3200-5U1 (1 set) ∗SY3200-5U1·····················1 set (2-position double part no.)
3-position closed center (24 VDC) ∗SY3300-5U1·····················1 set (3-position closed center part no.)
SY3300-5U1 (1 set)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.

• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in
Plug Assembly Part No.
One-touch Fittings/

order from the 1st station as shown in the figure above.


ide If the arrangement becomes complicated, specify on a manifold
Us specification sheet.
s
n
tio

Note) When mixing top ported configurations, select from page 164.
ta
S

3 Specify on a manifold specification sheet if plugs are required on the A


2
1 and B port on the manifold.
Manifold base (4 stations) ide
Manifold Options

Ds
SS5Y3-10SNAN-04D-C6

Protective class
class III (Mark: )

158
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 0 0 5 1
          
Base mounted

 Series  Pilot valve option  Manual override


3 SY3000 Nil Standard (102 psi (0.7 MPa)) Nil: D:
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Non-locking Push-turn
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa)) push type locking slotted
∗ Only metal seal type is available for the high type
pressure type.
 Type of actuation
1
2-position
Single  Coil type
2 Double Nil Standard E: F:
3 Closed center T With power saving circuit (Continuous duty type) Push-turn Slide locking
4 3-position Exhaust center locking lever type
∗ Be sure to select the power saving circuit type
type
5 Pressure center when a valve is continuously energized for long
A∗ N.C./N.C. periods of time.
4-position
B∗ dual 3-port
N.O./N.O. ∗ Be careful of the energizing time when the
C∗ N.C./N.O. power saving circuit is selected. Refer to page
244 for details.
∗ Only rubber seal type is available for the
∗ Refer to page 14 for with the safety slide locking
4-position dual 3-port valve.
 Rated voltage manual override.

5 24 VDC
 Seal type  Type of mounting screw
0 Rubber seal Nil Round head combination screw
1 Metal seal  Light/surge voltage suppressor B Hexagon socket head cap screw
and common specification Round head combination screw
Surge voltage Common K (Falling-out-prevention type)
Symbol With light
suppressor specification
 Pilot type R — H
Hexagon socket head cap screw
Non-polar (Falling-out-prevention type)
Nil Internal pilot U  ∗ For “K” and “H”, the valve body cover has a drop
R External pilot S — Positive
 prevention construction to stop the mounting
Z  common screws from falling out when the valve is
NS — Negative removed for maintenance etc.
NZ common ∗ When ordering a valve individually, the base
 Back pressure check valve 
gasket is not included. Since the base gasket is
(Built-in valve type) ∗ Select a valve from R, U, S or Z when the SI unit
attached to the manifold, please order the base
output polarity is Nil (positive common). Select a
Nil None valve from R, U, NS or NZ when the SI unit
gasket separately if it is needed for maintenance
H Built-in service.
output polarity is N (negative common).
Refer to page 220 for part numbers of the base
∗ Only rubber seal type. Manifold installed type is ∗ Only “Z” and “NZ” types are available for with
gasket and mounting screw.
available if the back pressure check valve is the power saving circuit.
∗ “B” and “H” cannot be selected for the individual
required for a valve with metal seal. Refer to SUP/EXH spacer assembly, interface regulator
page 232 for details. However, it is not or double check spacer assembly with residual
recommended to use the built-in valve type and pressure release valve.
the manifold installed type at the same time
because it will reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type and
the SY7000.

Protective class
class III (Mark: )

159
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY3000 Connector Connecting Base EX260

U C2
D - C3, N3 (D)
N1
B C4,

Sub-plate
C6, N7
D side U side
Manual override Note 2)

(
Push-turn locking slotted type:
Press, then rotate it. )

Plug-in
(L5) 4(A) port side : Blue (For rubber seal)
DIN rail holding screw L1
: Gray (For metal seal)
(For DIN rail mounting)
2(B) port side : Yellow
(Light/surge voltage
(DIN rail) suppressor) (8)

(5.5)

Metal Base
B A B A B A B A

(35)

92.6
14 A 14 A 14 A 14 A

83
80.2
(114.8)

60.5
(40.9)
12 B 12 B 12 B 12 B

4.6

Plug-in
22.2

4.6
1.7
(4.9) 4 x M4 mounting hole
SI unit
) C6: 3.6
N7: 7.4

Manifold Exploded View


(Fitting for the type with P/E

Type 50, 51, 52


ports on U and/or D sides)
(
L2 1.5
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)
One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: ø2

Connector Connecting Base


[Communication connector D-sub] Applicable tube O.D.: ø8, ø5/16" : ø3.2, ø1/8"
(Station 1) ----------- (Station n) : ø4, ø5/32"
: ø6, ø1/4"

BUS BUS OUT

manual override)
1 P

(Slide locking
1 P 1 P
76.7

76.7

63.1
10.6
13.6

BUS IN 68.8
56.6

3/5 E 2 B2
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

PWR 4 A4 PWR
21.6

4 A4 A4 A4 A4 A

Plug-in
18

46.5 46.5 (17.8)

Manifold Exploded View


(7.5)
(11.8)

15.5 (Pitch)

Type 10, 11, 12


P = 10.5
Note 1) These figures show the “SS5Y3-10SQA-05D-C6”.
Note 2) Refer to page 181 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 186 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
L1 103.7 114.2 124.7 135.2 145.7 156.2 166.7 177.2 187.7 198.2 208.7 219.2 229.7 240.2 250.7 261.2
Plug Assembly Part No.
One-touch Fittings/

L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5
L3 135.5 148 148 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 285.5
L4 125 137.5 137.5 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275 275
L5 16 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12

n: Stations 18 19 20 21 22 23 24
Manifold Options

L1 271.7 282.2 292.7 303.2 313.7 324.2 334.7


L2 231 241.5 252 262.5 273 283.5 294
L3 298 310.5 323 335.5 348 348 360.5
L4 287.5 300 312.5 325 337.5 337.5 350
L5 13 14 15 16 17 12 13

160
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base EX260

U C4, N3
SS5Y5-10S- D - C6, N7 (D)
B C8, N9
D side U side Manual override Note 2)

(Push-turn locking slotted type:


Press, then rotate it. )
DIN rail holding screw (L5) 4(A) port side : Blue (For rubber seal)
L1
(For DIN rail mounting) : Gray (For metal seal)
2(B) port side : Yellow
(Light/surge voltage suppressor)
(DIN rail) (8)

(5.5)
B A B A B A B A

(35)
14 A 14 A 14 A 14 A
(114.8)

97.5
113.4
101

81.2
(61.7)
5.5
12 B 12 B 12 B 12 B

10.9
1.4

4.7
(5.9)
(8.3)

SI unit
4 x M5 mounting hole

34.2 L2 1.5
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5) (Fitting for the type with P/E
(L3) ports on U and/or D sides)

One-touch fitting
[4(A), 2(B) port]
One-touch fitting Applicable tube O.D.: : ø4, ø5/32"
[Communication connector D-sub] [1(P), 3/5(E) port] : ø6, ø1/4"
Applicable tube O.D.: ø10 (Station 1) ----------- (Station n) : ø8, ø5/16"
: ø3/8"

BUS

manual override)
1 P BUS OUT (Slide locking
76.7

2 B2
78.9

1 P 1 P
76.7

14.1

73.2

3/5 E BUS IN 2 B2 B2 B2 B2 B
56.6

PWR

3/5 E 3/5 E
33.4

4 A4
29.1

PWR

4 A4 A4 A4 A4 A

48.2
8.7
12.4

(20.5)
(11.8)

(Pitch)
(7.5)

48.2 18 P=16

Note 1) These figures show the “SS5Y5-10SQA-05D-C8”.


Note 2) Refer to page 182 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 187 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 360.7
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320
L3 148 160.5 185.5 198 210.5 235.5 248 260.5 273 298 310.5 323 348 360.5 373 385.5
L4 137.5 150 175 187.5 200 225 237.5 250 262.5 287.5 300 312.5 337.5 350 362.5 375
L5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14 12.5

n: Stations 18 19 20 21 22 23 24
L1 376.7 392.7 408.7 424.7 440.7 456.7 472.7
L2 336 352 368 384 400 416 432
L3 410.5 423 435.5 448 473 485.5 498
L4 400 412.5 425 437.5 462.5 475 487.5
L5 17 15 13.5 11.5 16 14.5 12.5

161
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY7000 Connector Connecting Base EX260

C6, N7
U
SS5Y7-10S- Stations D - C8,
C10, N11 (D)
N9
D side U side

Sub-plate
B C12
(L5) L1
DIN rail holding screw Manual override Note 2)
(For DIN rail mounting) Light/surge voltage suppressor
(
Push-turn locking slotted type:
Press, then rotate it. )

Plug-in
4(A) port side: Blue (For rubber seal)
2(B) port side: Yellow

(8) (DIN rail)

B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A
102.3

128.8

Metal Base
115
(5.5)

96.7
(77.1)
12 B 12 B 12 B 12 B 12 B

5.5

Plug-in
14

8.8
3.9
SI unit
(6)
(9.3)

(A, B port: ø12) 4 x M5 mounting hole


(17.9)

Manifold Exploded View


34.4 L2 1.5 (Fitting for the type with P/E

Type 50, 51, 52


(5.3) (L4) ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting
[1(P), 3/5(E) port]

Connector Connecting Base


Applicable tube O.D.: ø12, ø1/2"
(Station 1) (Station n)
[Communication connector D-sub]

2
BUS OUT
BUS OUT
1 P 1 P
82.7
76.7

1 P 2 B2 B2 B2 B2 B
76.7

BUS IN
2 B2
56.6

BUS IN
3/5 E 3/5 E
11.1
35.2

8.7

31.6

3/5 E PWR 4 A4 A4 A4 A4 A

Plug-in
PWR 4 A4
14.2

Manifold Exploded View


(For DIN rail

(21.7)
(10)

mounting)

Type 10, 11, 12


53.2
(14.3)

(Pitch)
53.2 20.5 P = 19 One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
: ø10, ø3/8"
: ø12
Note 1) These figures show the “SS5Y7-10SQA-05D-C10”.
Plug Assembly Part No.

Note 2) Refer to page 183 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
One-touch Fittings/

Note 3) Refer to page 188 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 134.9 153.9 172.9 191.9 210.9 229.9 248.9 267.9 286.9 305.9 324.9 343.9 362.9 381.9 400.9 419.9 438.9 457.9 476.9 495.9 514.9 533.9 552.9
Manifold Options

L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 160.5 185.5 198 223 235.5 260.5 273 298 310.5 335.5 348 373 398 410.5 435.5 448 473 485.5 510.5 523 548 560.5 585.5
L4 150 175 187.5 212.5 225 250 262.5 287.5 300 325 337.5 362.5 387.5 400 425 437.5 462.5 475 500 512.5 537.5 550 575
L5 13 16 12.5 15.5 12.5 15.5 12 15 12 15 11.5 14.5 17.5 14.5 17.5 14 17 14 17 13.5 16.5 13.5 16.5

162
Plug-in Connector Connecting Base
RoHS
EX260

Series SY3000/5000/7000
Type 12
Top Ported
How to Order Manifold

Refer to pages 186 to 188


SS5Y 3 12S NA N 05 U
for Type 12/Top ported
dimensions.        
 Series  Valve stations  P, E port entry
3 SY3000 In the case of the 32-output SI unit U Note) U side (2 to 10 stations)
5 SY5000 Symbol Stations Note D Note) D side (2 to 10 stations)
7 SY7000 02 2 stations B Both sides (2 to 24 stations)
Double wiring Note 1)
···

··· Note)  For type “S”, supply/exhaust block assembly with


 SI unit specifications 16 16 stations built-in silencer, choose U or D for P port entry.
Number of Communication 02 2 stations
Symbol Protocol outputs connector Specified layout Note 2)
 SUP/EXH block assembly
···

···

(Available up to 32 solenoids)
0 Without SI unit 24 24 stations
Nil Internal pilot
QA 32 In the case of the 16-output SI unit
DeviceNet™ M12 S Internal pilot, Built-in silencer
QB 16
Symbol Stations Note
NA 32
R External pilot
M12 02 2 stations
NB PROFIBUS 16 ∗ For built-in silencer type, P and E ports are available on U
Double wiring Note 1)
···

···

and D sides. 3/5(E) port is plugged. The silencer exhaust


NC DP 32 08 8 stations
D-sub Note) port is located on the opposite side of P, E port entry.
ND 16 02 2 stations (Example: When the P, E port entry is D side, the silencer
VA 32 Specified layout Note 2) exhaust port is U side.)
CC-Link M12
···

···

VB 16 (Available up to 16 solenoids) ∗ When the built-in silencer type is used, keep the exhaust
16 16 stations port from coming in direct contact with water or other
DA 32
Note 1) Double wiring: 2-position single, double,
EtherCAT M12 liquids.
DB 16 3-position and 4-position valves can be used
FA 32 on all manifold stations.  P, E port size (One-touch fittings)
PROFINET M12 Use of a 2-position single solenoid will result
FB 16
in an unused control signal. If this is not Symbol SY3000 SY5000 SY7000
EA 32
EtherNet/IP™ M12 desired, order with a specified layout.
EB 16 Note 2) Specified layout: Indicate the wiring Nil ø8 ø10 ø12
Note) IP40 for the D-sub applicable communication specifications on the manifold specification
connector specification. sheet. N ø5/16" ø3/8" ø1/2"
DIN rail cannot be mounted without SI unit. (Note that 2-position double, 3-position and ∗ For N, sizes are in inches.
4-position valves cannot be used where
 SI unit output polarity single wiring has been specified.)  Mounting
Note 3) This also includes the number of blanking
Nil Positive common (NPN) plate assembly. Nil Direct mounting
N Negative common (PNP) Note 4) For the model without the SI unit (S0), note D DIN rail mounting (With DIN rail)
Note 1) Ensure a match with the common
the maximum number of solenoids of the SI D0 DIN rail mounting (Without DIN rail)
unit that will be mounted. If the layout is D3 For 3 stations
specification of the valve to be used. specified, indicate it on the manifold Specify a longer rail than
Note 2) Without SI unit, the symbol is nil.
···

···

specification sheet. the standard length.


D24 For 24 stations
For details about the EX260 Integrated-type (For Output) Serial Transmission System, refer to the WEB Note 1) When it is necessary to mount a DIN rail without an
catalog or the Best Pneumatics No. 1 and the Operation Manual. For details about part numbers of SI SI unit, select D0 and order DIN rail length
units to be mounted, refer to page 216 in this catalog. Please download the Operation Manual via SMC separately, referring to L3 in the dimensions. Refer
website, http://www.smcworld.com to page 225 for part numbers of DIN rail.
Note 2) Refer to page 247 for the fixation of DIN rail
How to Order Manifold Assembly mounting type manifold.

Example (SS5Y3-12SNAN-)
2-position single (24 VDC) 2-position double (24 VDC)
SS5Y3-12SNAN-04D ····· 1 set (Type 12 4-station manifold base part no.)
SY3130-5U1-C6 (2 sets) SY3230-5U1-C6 (1 set)
∗SY3130-5U1-C6 ············· 2 sets (2-position single part no.)
3-position closed center (24 VDC) ∗SY3230-5U1-C6 ············· 1 set (2-position double part no.)
SY3330-5U1-C6 (1 set) ∗SY3330-5U1-C6 ············· 1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.

• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in
de

order from the 1st station as shown in the figure above.


si
U

If the arrangement becomes complicated, specify on a manifold


s
n
tio
ta

specification sheet.
S
3
2
1

Manifold base (4 stations)


de
si
D

SS5Y3-12SNAN-04D

163
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
            

Plug-in
Top ported

 Series  Coil type  A, B port size


3 SY3000 Nil Standard Thread piping
5 SY5000 T With power saving circuit (Continuous duty type) Symbol Port size Applicable series
7 SY7000 ∗ Be sure to select the power saving circuit type M5 M5 x 0.8 SY3000
when a valve is continuously energized for long 01 1/8 SY5000

Metal Base
periods of time. 02 1/4 SY7000
 Type of actuation ∗ Be careful of the energizing time when the
power saving circuit is selected. Refer to page One-touch fitting (Metric)
1 Single 244 for details.
2-position Symbol A, B port SY3000 SY5000 SY7000
2 Double
C2 ø2  — —
3 Closed center  Rated voltage

Plug-in
C3 ø3.2  — —
4 3-position Exhaust center
5 24 VDC C4 ø4   —
5 Pressure center
C6 ø6   
A∗ N.C./N.C.
4-position C8 ø8 —  
B∗ N.O./N.O.
C∗
dual 3-port
N.C./N.O.  Light/surge voltage suppressor C10 ø10 — — 
C12

Manifold Exploded View


and common specification ø12 — — 
∗ Only rubber seal type is available for the

Type 50, 51, 52


4-position dual 3-port valve. Symbol With light
Surge voltage Common One-touch fitting (Inch)
suppressor specification Symbol A, B port SY3000 SY5000 SY7000
R — N1 ø1/8"  — —
Non-polar
 Seal type U  N3 ø5/32"   —
S — Positive N7 ø1/4"   
0 Rubber seal 
common
Z  N9 ø5/16" —  
1 Metal seal
NS — Negative N11 ø3/8" — — 
NZ  common

Connector Connecting Base


 Pilot type ∗ Select a valve from R, U, S or Z when the SI unit
output polarity is Nil (positive common).  Thread type
Nil Internal pilot Select a valve from R, U, NS or NZ when the SI
R External pilot unit output polarity is N (negative common). Nil Rc
∗ Only “Z” and “NZ” types are available for with F G
the power saving circuit. N NPT
T NPTF
 Back pressure check valve ∗ Only Nil is available for M5.
(Built-in valve type)
Nil None  Manual override

Plug-in
H Built-in Nil: D:  Type of mounting screw
∗ Only rubber seal type. Manifold installed type is Non-locking Push-turn
available if the back pressure check valve is push type locking slotted Nil Round head combination screw

Manifold Exploded View


required for a valve with metal seal. Refer to type B Hexagon socket head cap screw

Type 10, 11, 12


page 232 for details. However, it is not Round head combination screw
K (Falling-out-prevention type)
recommended to use the built-in valve type and
the manifold installed type at the same time Hexagon socket head cap screw
because it will reduce the flow. H (Falling-out-prevention type)
∗ The built-in valve type back pressure check
valve is not available for the 3-position type and E: F: ∗ For “K” and “H”, the valve body cover has a drop
the SY7000. Push-turn Slide locking prevention construction to stop the mounting
locking lever type screws from falling out when the valve is
type removed for maintenance etc.
 Pilot valve option ∗ When ordering a valve individually, the base
Plug Assembly Part No.

gasket is not included. Since the base gasket is


One-touch Fittings/

Nil Standard (102 psi (0.7 MPa)) attached to the manifold, please order the base
B Quick response type (102 psi (0.7 MPa)) gasket separately if it is needed for maintenance
K∗ High pressure type (145 psi (1.0 MPa)) service.
∗ Refer to page 14 for with the safety slide locking Refer to page 220 for part numbers of the base
∗ Only metal seal type is available for the high manual override.
pressure type. gasket and mounting screw.
∗ “B” and “H” cannot be selected for the individual
SUP/EXH spacer assembly or interface
Manifold Options

regulator.

Protective class
class III (Mark: )

164
Type 10 Plug-in Connector Connecting Base RoHS
Side Ported
EX126

Series SY3000/5000/7000
Type 11
Bottom Ported

How to Order Manifold

Refer to pages 184 (SY5000)


and 185 (SY7000) for
SS5Y 3 10 S4 V 05 U C6
dimensions of Type
11/Bottom ported type.        
 Series  Type  Valve stations
3 SY3000 10 Side ported Symbol Stations Note
5 SY5000 11 Bottom ported∗ 02 2 stations
7 SY7000 ∗ The SY5000 manifold base is used for the Double wiring Note 1)

···

···
bottom ported of the SY3000. When ordering, 08 8 stations
refer to “Plug-in Mixed Mounting Type Manifold” 02 2 stations
(from page 189). Specified layout Note 2)

···

···
(Available up to 16 solenoids)
16 16 stations
Note 1) Double wiring: 2-position single, double,
 SI unit 3-position and 4-position valves can be used on
0 Without SI unit all manifold stations.
V CC-Link (Positive common NPN) Use of a 2-position single solenoid will result in
an unused control signal. If this is not desired,
∗ Only a terminal block plate is mounted for the
order with a specified layout.
valve without SI unit.
Note 2) Specified layout: Indicate the wiring
specifications with the manifold specification
sheet. (Note that 2-position double, 3-position
How to Order Manifold Assembly and 4-position valves cannot be used where
single wiring has been specified.)
Note 3) This also includes the number of blanking plate
Example (SS5Y3-10S4V--) assembly.

2-position double (24 VDC)


2-position single (24 VDC) SY3200-5U1 (1 set)  P, E port entry
SY3100-5U1 (3 sets)
3-position closed U U side (2 to 10 stations)
SI unit center (24 VDC) D D side (2 to 10 stations)
SY3300-5U1 (1 set) B Both sides (2 to 16 stations)

 SUP/EXH block assembly


Nil Internal pilot
ide S
Us Internal pilot, Built-in silencer
s
ati
on R External pilot
St
3 ∗ 3/5(E) port is plugged for the built-in silencer type.
2 ∗ When the built-in silencer type is used, keep the
1
e exhaust port from coming in direct contact with water
D sid
or other liquids.

Terminal block plate assembly


Manifold base (5 stations)
SS5Y3-10S4V-05D-C6
For details about the EX126 Integrated-type (For Output) Serial
SS5Y3-10S4V-05D-C6 ···1 set (Type 10 5-station manifold base part no.) Transmission System, refer to the WEB catalog or the Best
∗SY3100-5U1 ···················3 sets (2-position single part no.) Pneumatics No. 1 and the Operation Manual. For details about
∗SY3200-5U1 ···················1 set (2-position double part no.) part numbers of SI units to be mounted, refer to page 217 in
∗SY3300-5U1 ···················1 set (3-position closed center part no.) this catalog. Please download the Operation Manual via SMC
The asterisk denotes the symbol for assembly. website, http://www.smcworld.com
Prefix it to the part numbers of the valve etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order
from the 1st station as shown in the figure above. If the arrangement
becomes complicated, specify on a manifold specification sheet.
Note) When mixing top ported configurations, select from page 172.
In this case, use caution as there is also output on the A and B port on base
side.
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side.

165
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Sub-plate
 A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)

Plug-in
Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2  — — — — N1 ø1/8"  — — — —
C3 ø3.2  — — — — N3 ø5/32"   —  —

Straight
C4 ø4   —  — N7 ø1/4"     
Straight

C6 ø6      N9 ø5/16" —    
C8 ø8 — N11 ø3/8" — — —

Metal Base
     
C10 ø10 — —  —  CM∗ Straight port, mixed sizes     
C12 ø12 — —  —  LN3 ø5/32"  — — — —
CM∗

Upward
Straight port, mixed sizes      LN7 ø1/4"   — — —
L4 — — — LN9

Plug-in
ø4   ø5/16" —  — — —
L6 ø6    — — LN11 ø3/8" — —  — —
Upward

Elbow Note)
L8 ø8 —   — — BN3 ø5/32"  — — — —

Downward
L10 ø10 — —  — — BN7 ø1/4"   — — —
L12 ø12 — —  — — BN9 ø5/16" —  — — —
Elbow Note)

Manifold Exploded View


B4 ø4   — — — BN11 ø3/8" — —  — —

Type 50, 51, 52


Downward

B6 ø6    — — Elbow port, mixed sizes


LM∗ (Including upward and    — —
B8 ø8 —   — — downward piping)

B10 ø10 — —  — — P, E port size


ø5/16" ø3/8" ø1/2" ø3/8" ø1/2"
B12 ø12 — —  — — (One-touch fittings)
Elbow port, mixed sizes
LM∗ (Including upward and    — —
downward piping)

P, E port size

Connector Connecting Base


ø8 ø10 ø12 ø10 ø12
(One-touch fittings)

Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 226 to 228).
∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting direction.

 Mounting and Option


Option

Plug-in
Symbol Mounting
Name plate Station number
Nil — —
Direct
AA mounting
 

Manifold Exploded View


BA  —

Type 10, 11, 12


D — —
DIN rail
A mounting
 
B  —
Note 1) Enter the number of stations inside 
when it is larger than the number of valve
stations. (Refer to “DIN Rail Option”
below.)
Note 2) Only direct mounting is available for Type
11 (Bottom ported).
Plug Assembly Part No.
One-touch Fittings/

Note 3) Refer to page 247 for the fixation of DIN


rail mounting type manifold.
DIN Rail Option
Nil Direct mounting
0 Without DIN rail (with bracket)
3 For 3 stations Specify a longer rail
Manifold Options

than the total length


···

···

16 For 16 stations of specified stations.

Protective class
class III (Mark: )

166
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 0 0 5 1
          
Base mounted

 Series  Pilot valve option  Manual override


3 SY3000 Nil Standard (102 psi (0.7 MPa)) Nil: D:
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Non-locking Push-turn
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa)) push type locking
∗ Only metal seal type is available for the high slotted
pressure type. type

 Type of actuation
1 Single  Coil type
2-position E: F:
2 Double Nil Standard Push-turn Slide locking
3 Closed center T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust center ∗ Be sure to select the power saving circuit type lever
5 Pressure center when the valve is continuously energized for type
A∗ N.C./N.C. long periods of time.
4-position ∗ Be careful of the energizing time when the
B∗ dual 3-port
N.O./N.O.
power saving circuit is selected. Refer to page
C∗ N.C./N.O.
244 for details. ∗ Refer to page 14 for with the safety slide locking
∗ Only rubber seal type is available for the manual override.
4-position dual 3-port valve.
 Rated voltage
5 24 VDC  Type of mounting screw
 Seal type
Nil Round head combination screw
0 Rubber seal
B Hexagon socket head cap screw
1 Metal seal
 Light/surge voltage suppressor K
Round head combination screw
and common specification (Falling-out-prevention type)
Surge voltage Common H Hexagon socket head cap screw
 Pilot type Symbol With light (Falling-out-prevention type)
suppressor specification
Nil Internal pilot R — ∗ For “K” and “H”, the valve body cover has a drop
Non-polar prevention construction to stop the mounting
R External pilot U 
 screws from falling out when the valve is
S — Positive
removed for maintenance etc.
Z  common
∗ When ordering a valve individually, the base
∗ Only “Z” type is available for with the power gasket is not included. Since the base gasket is
 Back pressure check valve saving circuit. attached to the manifold, please order the base
(Built-in valve type) gasket separately if it is needed for maintenance
Nil None service.
H Built-in Refer to page 220 for part numbers of base
gasket and mounting screw.
∗ Only rubber seal type. Manifold installed type is ∗ “B” and “H” cannot be selected for the individual
available if the back pressure check valve is SUP/EXH spacer assembly, interface regulator
required for a valve with metal seal. Refer to or double check spacer assembly with residual
page 232 for Ordering Example. However, it is pressure release valve.
not recommended to use the built-in valve type
and the manifold installed type at the same time
because it will reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type and
the SY7000.

Protective class
class III (Mark: )

167
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY3000 Connector Connecting Base EX126

U C2
N1 ( )
SS5Y3-10S4V- Stations D - C3, D

Sub-plate
B C4, N3 C6, N7
D side U side
Manual override Note 2)
(L5) L1
DIN rail holding screw (Push-turn locking slotted type:
)

Plug-in
(Light/surge voltage suppressor) Press, then rotate it.
(For DIN rail mounting)
DIN rail holding screw 4(A) port side : Blue (For rubber seal)
DIN rail : Gray (For metal seal)
(For DIN rail mounting)
2(B) port side : Yellow

(5.5)
(8)
B A B A B A B A B A

Metal Base
(35)

92.6
14 A 14 A 14 A 14 A 14 A

83
116
42

80

60.5
(40.9)
4.6
12 B 12 B 12 B 12 B 12 B
36.6

Plug-in
4.6
11

1.7
)
(4.9)

15.4
4 x M4

C6: 3.6
N7: 7.4
55.4
mounting hole
2 x M5 mounting hole

(
1 (Fitting for the type with P/E

Manifold Exploded View


7.1 88.2 L2 1.5 ports on the U and/or D sides)

Type 50, 51, 52


(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

4 x G1/2 One-touch fitting


Signal/Electrical entry [1(P), 3/5(E) port] One-touch fitting
Applicable tube O.D.: ø8, ø5/16" [4(A), 2(B) port]
2.6

SI unit Applicable tube O.D.: ø2

Connector Connecting Base


: ø3.2, ø1/8"
(Station 1) --- (Station n) : ø4, ø5/32"
: ø6, ø1/4"
90.7

1 P 1 P

63.1
13.6
10.6

56.6
55.4

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

4 A4 A4 A4 A4 A
21.6
18

Plug-in
13.2

(For DIN rail

33.4
(7.5)

mounting)

(Pitch)
(11.8)

Terminal block plate assembly

Manifold Exploded View


107.1 15.5 P = 10.5 (17.8)

Type 10, 11, 12


Note 1) These figures show the “SS5Y3-10S4V-05D-C6”.
Note 2) Refer to page 181 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 186 for dimensions of A or B port top-ported type.
Plug Assembly Part No.
One-touch Fittings/

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 164.3 174.8 185.3 195.8 206.3 216.8 227.3 237.8 248.3 258.8 269.3 279.8 290.3 300.8 311.3
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210
Manifold Options

L3 198 198 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 335.5 335.5
L4 187.5 187.5 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 325 325
L5 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12

168
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base EX126

U C4, N3
SS5Y5-10S4V - Stations D - C6, N7 (D)
B C8, N9

D side U side
Manual override Note 2)
(L5) L1
DIN rail holding screw
(For DIN rail mounting)
DIN rail holding screw (Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail (Light/surge voltage suppressor) : Gray (For metal seal)
2(B) port side : Yellow

(5.5)
(8)
B A B A B A B A B A

(35)
14 A 14 A 14 A 14 A 14 A
121.4
116
42

97.5
113.4
80

81.2
(61.7)
5.5
42.4

12 B 12 B 12 B 12 B 12 B

10.9
16.4

4.7
55.4
(5.9)
(8.3)

2 x M5 mounting hole 4 x M5 mounting hole

7.1 87.7 L2 1.5 (Fitting for the type with P/E


ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

4 x G1/2 One-touch fitting


Signal/Electrical entry [1(P), 3/5(E) port]
One-touch fitting
Applicable tube O.D.: ø10, ø3/8"
[4(A), 2(B) port]
2.6

SI unit (Station 1) ----------- (Station n) Applicable tube O.D.: ø4, ø5/32"


: ø6, ø1/4"
: ø8, ø5/16"
90.7

1 P 1 P
14.1

73.2
8.7

2 B2 B2 B2 B2 B
56.6
55.4

3/5 E 3/5 E
33.4

29.1

4 A4 A4 A4 A4 A
13.2
12.4

33.4
(For DIN rail

(Pitch)
(7.5)

mounting)

Terminal block plate assembly (20.5)


(11.8)

108.8 18 P = 16

Note 1) These figures show the “SS5Y5-10S4V-05D-C8”.


Note 2) Refer to page 182 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 187 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 181.3 197.3 213.3 229.3 245.3 261.3 277.3 293.3 309.3 325.3 341.3 357.3 373.3 389.3 405.3
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304
L3 210.5 223 248 260.5 273 285.5 310.5 323 335.5 360.5 373 385.5 398 423 435.5
L4 200 212.5 237.5 250 262.5 275 300 312.5 325 350 362.5 375 387.5 412.5 425
L5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14 12.5 17 15

169
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY7000 Connector Connecting Base EX126

U C6, N7
SS5Y7-10S4- Stations D - C8, N9 ( )
C10, N11 D

Sub-plate
B C12
D side U side
(L5) L1
Manual override Note 2)

(Push-turn locking slotted type:


)

Plug-in
DIN rail holding screw DIN rail holding screw (Light/surge voltage suppressor) Press, then rotate it.
(For DIN rail mounting) (For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
: Gray (For metal seal)
2(B) port side: Yellow

(8) (DIN rail)

B A B A B A B A B A

Metal Base
(35)
14 A 14 A 14 A 14 A 14 A
116
42

136.8

80

128.8
115
(5.5)

96.7
(77.1)

Plug-in
57.8

12 B 12 B 12 B 12 B 12 B

5.5
31.8

8.8
4 x M5

3.9
(6)
(9.3)

Manifold Exploded View


55.4 mounting hole
2 x M5 mounting hole (A, B port: ø12)

Type 50, 51, 52


1 (17.9) (Fitting for the type with P/E
7.1 87.9 L2 1.5 ports on the U and/or D sides)

(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting
[1(P), 3/5(E) port]

Connector Connecting Base


Applicable tube O.D.: ø12, ø1/2"

4 x G1/2 SI unit
(2.6)

(Signal/Electrical entry) (Station 1) (Station n)

Plug-in
90.7

1 P 1 P 82.7
2 B2 B2 B2 B2 B
56.6
55.4

3/5 E 3/5 E
11.1
35.2

8.7

31.6

4 A4 A4 A4 A4 A

Manifold Exploded View


Type 10, 11, 12
13.2
14.2

(For DIN rail

(21.7)
mounting)
(10)

(14.3)

33.4 (Pitch)
Terminal block plate assembly
113.8 20.5 P = 19
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
Plug Assembly Part No.
One-touch Fittings/

Note 1) These figures show the “SS5Y7-10S4V-05D-C10”. : ø10, ø3/8"


Note 2) Refer to page 183 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override. : ø12
Note 3) Refer to page 188 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Manifold Options

L1 195.5 214.5 233.5 252.5 271.5 290.5 309.5 328.5 347.5 366.5 385.5 404.5 423.5 442.5 461.5
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360
L3 223 248 260.5 285.5 298 323 335.5 360.5 373 398 410.5 435.5 448 473 485.5
L4 212.5 237.5 250 275 287.5 312.5 325 350 362.5 387.5 400 425 437.5 462.5 475
L5 14 17 13.5 16.5 13.5 16.5 13 16 13 16 12.5 15.5 12.5 15.5 12

170
Plug-in Connector Connecting Base
RoHS
EX126
Type 12
Top Ported
Series SY3000/5000/7000
How to Order Manifold

Refer to pages 186 to 188


SS5Y 3 12S4 V 05 U
for dimensions of Type
12/Top ported type.
      
 Series  Valve stations  P, E port entry
3 SY3000 Symbol Stations Note U Note) U side (2 to 10 stations)
5 SY5000 02 2 stations D Note) D side (2 to 10 stations)
7 SY7000 Double wiring Note 1) B Both sides (2 to 16 stations)
···

···

08 8 stations Note)  For type “S”, supply/exhaust block


02 2 stations assembly with built-in silencer, choose U or
 SI unit Specified layout Note 2) D for P port entry.
···

···

(Available up to 16 solenoids)
0 Without SI unit 16 16 stations
V CC-Link (Positive common NPN)
∗ Only a terminal block plate is mounted for the
Note 1) Double wiring: 2-position single, double,
3-position and 4-position valves can be used
 SUP/EXH block assembly
valve without SI unit. on all manifold stations. Nil Internal pilot
Use of a 2-position single solenoid will result S Internal pilot, Built-in silencer
in an unused control signal. If this is not R External pilot
desired, order with a specified layout.
Note 2) Specified layout: Indicate the wiring ∗ For built-in silencer type, P and E ports are
specifications on the manifold specification available on U and D sides. 3/5(E) port is
sheet. (Note that 2-position double, 3-position plugged. The silencer exhaust port is located on
and 4-position valves cannot be used where the opposite side of P, E port entry. (Example:
single wiring has been specified.) When the P, E port entry is D side, the silencer
Note 3) This also includes the number of blanking exhaust port is U side.)
plate assembly. ∗ When the built-in silencer type is used, keep the
exhaust port from coming in direct contact with
How to Order Manifold Assembly water or other liquids.

Example (SS5Y3-12S4V--)  P, E port size (One-touch fittings)


2-position double (24 VDC) Symbol SY3000 SY5000 SY7000
2-position single (24 VDC) SY3230-5U1-C6 (1 set) Nil ø8 ø10 ø12
SY3130-5U1-C6 (3 sets) 3-position closed
center (24 VDC) N ø5/16" ø3/8" ø1/2"
SI unit
SY3330-5U1-C6 (1 set) ∗ For N, sizes are in inches.

 Mounting
Nil Direct mounting
ide D DIN rail mounting (With DIN rail)
Us D0 DIN rail mounting (Without DIN rail)
s
on
ati D3 For 3 stations Specify a longer rail
St
3 than the standard
···

···

2
1 D16 For 16 stations length.
e
D sid
Note) Refer to page 247 for the fixation of DIN rail
mounting type manifold.
Terminal block plate assembly

Manifold base (5 stations)


SS5Y3-12S4V-05D

SS5Y3-12S4V-05D ···1 set (Type 12 5-station manifold base part no.)


∗SY3130-5U1-C6 ········3 sets (2-position single part no.)
∗SY3230-5U1-C6 ········1 set (2-position double part no.)
∗SY3330-5U1-C6 ········1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
For details about the EX126 Integrated-type (For Output) Serial
• The valve arrangement is numbered as the 1st station from the D side. Transmission System, refer to the WEB catalog or the Best
• Under the manifold part number, state the valves to be mounted in order Pneumatics No. 1 and the Operation Manual. For details about
from the 1st station as shown in the figure above. If the arrangement part numbers of SI units to be mounted, refer to page 217 in
becomes complicated, specify on a manifold specification sheet. this catalog. Please download the Operation Manual via SMC
website, http://www.smcworld.com

171
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
            

Plug-in
Top ported

 Series  Pilot valve option  A, B port size


3 SY3000 Nil Standard (102 psi (0.7 MPa)) Thread piping
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Symbol Port size Applicable series
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa)) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000

Metal Base
pressure type. 02 1/4 SY7000
 Type of actuation  Coil type One-touch fitting (Metric)
1 Single Symbol A, B port SY3000 SY5000 SY7000
2-position Nil Standard C2 ø2 — —
2 Double 
T

Plug-in
With power saving circuit (Continuous duty type) C3 ø3.2 — —
3 Closed center 
4 3-position Exhaust center ∗ Be sure to select the power saving circuit type C4 ø4   —
when the valve is continuously energized for C6 ø6
5 Pressure center
long periods of time.
  
A∗ N.C./N.C. ∗ Be careful of the energizing time when the
C8 ø8 —  
4-position
B∗ dual 3-port
N.O./N.O. power saving circuit is selected. Refer to page C10 ø10 — — 
C∗ C12

Manifold Exploded View


N.C./N.O. 244 for details. ø12 — — 

Type 50, 51, 52


∗ Only rubber seal type is available for the One-touch fitting (Inch)
4-position dual 3-port valve.
 Rated voltage Symbol A, B port SY3000 SY5000 SY7000
N1 ø1/8"  — —
 Seal type 5 24 VDC
N3 ø5/32"   —
0 Rubber seal N7 ø1/4"   
1 Metal seal N9 ø5/16" —  
 Light/surge voltage suppressor N11 ø3/8" — — 
and common specification

Connector Connecting Base


Surge voltage Common
 Pilot type Symbol With light
suppressor specification  Thread type
Nil Internal pilot R — Nil Rc
Non-polar
R External pilot U  F G

S — Positive N NPT
Z  common T NPTF
∗ Only “Z” type is available for with the power ∗ Only Nil is available for M5.
 Back pressure check valve saving circuit.
(Built-in valve type)

Plug-in
Nil None
H Built-in  Manual override  Type of mounting screw
∗ Only rubber seal type. Manifold installed type is Nil

Manifold Exploded View


Nil: D: Round head combination screw
available if the back pressure check valve is

Type 10, 11, 12


Non-locking Push-turn B Hexagon socket head cap screw
required for a valve with metal seal. Refer to push type locking slotted Round head combination screw
page 232 for Ordering Example. However, it is type
K (Falling-out-prevention type)
not recommended to use the built-in valve type
Hexagon socket head cap screw
and the manifold installed type at the same time H (Falling-out-prevention type)
because it will reduce the flow.
∗ The built-in valve type back pressure check ∗ For “K” and “H”, the valve body cover has a drop
valve is not available for the 3-position type and prevention construction to stop the mounting
the SY7000. E: F: screws from falling out when the valve is
Push-turn Slide locking removed for maintenance etc.
Plug Assembly Part No.

locking lever type ∗ When ordering a valve individually, the base


One-touch Fittings/

type gasket is not included. Since the base gasket is


attached to the manifold, please order the base
gasket separately if it is needed for maintenance
service.
Refer to page 220 for part numbers of base
gasket and mounting screw.
∗ Refer to page 14 for with the safety slide locking ∗ “B” and “H” cannot be selected for the individual
Manifold Options

manual override. SUP/EXH spacer assembly or interface


regulator.

Protective class
class III (Mark: )

172
Type 10 Plug-in Connector Connecting Base
Side Ported RoHS
EX120

Series SY3000/5000/7000
Type 11
Bottom Ported

How to Order Manifold

Refer to pages 184 (SY5000)


and 185 (SY7000) for
SS5Y 3 10 S3 R1 05 U C6
dimensions of Type
11/Bottom ported type.        
 Series  SI unit  Valve stations
3 SY3000 0 Without SI unit Symbol Stations Note
5 SY5000 Q DeviceNet™ (Positive common NPN) 02 2 stations
7 SY7000 R1 OMRON CompoBus/S 16 outputs Double wiring Note 1)

···

···
R2 (Positive common NPN) 8 outputs 08 8 stations
V CC-Link (Positive common NPN) 02 2 stations
 Type ZB Note 2) Positive common NPN
Specified layout Note 2)

···

···
CompoNet™ (Available up to 16 solenoids)
10 Side ported ZBN Note 2) Negative common PNP 16 16 stations
11 Bottom ported∗ Note 1) Ensure a match with the common specification Note 1) Double wiring: 2-position single, double,
∗ The SY5000 manifold base is used for the of the valve to be used. 3-position and 4-position valves can be
bottom ported of the SY3000. When ordering, Note 2) The communication connector (for the opposite used on all manifold stations.
refer to “Plug-in Mixed Mounting Type Manifold” side) is not provided. Please order it Use of a 2-position single solenoid will
(from page 189). separately. result in an unused control signal. If this is
not desired, order with a specified layout.
Note 2) Specified layout: Indicate the wiring
specifications on the manifold
specification sheet. (Note that 2-position
double, 3-position and 4-position valves
cannot be used where single wiring has
How to Order Manifold Assembly been specified.)
Note 3) This also includes the number of blanking
plate assembly.
Example (SS5Y3-10S3V-) Note 4) Since R2 type SI unit has 8 outputs, note
that up to 8 solenoids can be
accommodated.
2-position double (24 VDC)
2-position single (24 VDC) SY3200-5U1 (1 set)
SY3100-5U1 (3 sets) 3-position closed
 P, E port entry
center (24 VDC) U U side (2 to 10 stations)
SY3300-5U1 (1 set) D D side (2 to 10 stations)
B Both sides (2 to 16 stations)

 SUP/EXH block assembly


Nil Internal pilot
ide S Internal pilot, Built-in silencer
Us
on
s R External pilot
ati
St ∗ 3/5(E) port is plugged for the built-in silencer type.
3
2
1
e
D sid
Manifold base (5 stations)
SS5Y3-10S3V-05D-C6

SS5Y3-10S3V-05D-C6 ···1 set (Type 10 5-station manifold base part no.)


∗SY3100-5U1 ···················3 sets (2-position single part no.)
∗SY3200-5U1 ···················1 set (2-position double part no.)
∗SY3300-5U1 ···················1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order from For details about the EX120 Integrated-type (For Output) Serial
the 1st station as shown in the figure above. If the arrangement becomes Transmission System, refer to the WEB catalog or the Best
complicated, specify on a manifold specification sheet. Pneumatics No. 1 and the Operation Manual. For details about
part numbers of SI units to be mounted, refer to page 218 in
Note) When mixing top ported configurations, select from page 180.
this catalog. Please download the Operation Manual via SMC
In this case, use caution as there is also output on the A and B port on base
side. website, http://www.smcworld.com
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side.

173
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
 A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)

Sub-plate
Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 ø2  — — — — N1 ø1/8"  — — — —

Plug-in
C3 ø3.2  — — — — N3 ø5/32"   —  —

Straight
C4 ø4   —  — N7 ø1/4"     
Straight

C6 ø6      N9 ø5/16" —    
C8 ø8 —     N11 ø3/8" — —  — 
C10 ø10 — —  —  CM∗ Straight port, mixed sizes     
C12 ø12 — —  —  LN3 ø5/32"  — — — —
CM∗

Upward
Straight port, mixed sizes      LN7 ø1/4"   — — —

Metal Base
L4 ø4   — — — LN9 ø5/16" —  — — —
L6 ø6    — — LN11 ø3/8" — —  — —
Upward

Elbow Note)
L8 ø8 —   — — BN3 ø5/32"  — — — —

Downward
L10 ø10 — —  — — BN7 ø1/4"   — — —

Plug-in
L12 ø12 — —  — — BN9 ø5/16" —  — — —
Elbow Note)

B4 ø4   — — — BN11 ø3/8" — —  — —
Downward

B6 ø6    — — Elbow port, mixed sizes


LM∗ (Including upward and    — —
B8 ø8 —   — — downward piping)

B10 ø10 — —  — — P, E port size

Manifold Exploded View


ø5/16" ø3/8" ø1/2" ø3/8" ø1/2"
B12 (One-touch fittings)

Type 50, 51, 52


ø12 — —  — —
Elbow port, mixed sizes
LM∗ (Including upward and    — —
downward piping)

P, E port size
ø8 ø10 ø12 ø10 ø12
(One-touch fittings)

Note) To avoid interference with the body or piping, select downward elbow port when mounting the optional spacer assembly (pages 226 to 228).
∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.

Connector Connecting Base


∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”, indicate it on the manifold specification sheet for the P, E port fitting direction.

 Mounting and Option


Option
Symbol Mounting
Name plate Station number
Nil — —
Direct
AA mounting
 
BA  —

Plug-in
D — —
DIN rail
A mounting
 
B  —

Manifold Exploded View


Note 1) Enter the number of stations inside 

Type 10, 11, 12


when it is larger than the number of valve
stations. (Refer to “DIN Rail Option”
below.)
Note 2) Only direct mounting is available for Type
11 (Bottom ported).
Note 3) Refer to page 247 for the fixation of DIN
rail mounting type manifold.
DIN Rail Option
Nil Direct mounting
Plug Assembly Part No.
One-touch Fittings/

0 Without DIN rail (with bracket)


3 For 3 stations Specify a longer rail
than the total length
···

···

16 For 16 stations of specified stations.


∗ When it is necessary to mount a DIN rail without
an SI unit, select D0 and order DIN rail length
Manifold Options

separately, referring to L3 in the dimensions.


(Refer to page 225 for part numbers of DIN rail.)

Protective class
class III (Mark: )

174
Series SY3000/5000/7000

How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 0 0 5 1
          
Base mounted

 Series  Pilot valve option  Manual override


3 SY3000 Nil Standard (102 psi (0.7 MPa)) Nil: D:
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Non-locking Push-turn
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa)) push type locking
slotted
∗ Only metal seal type is available for the high
type
pressure type.
 Type of actuation
1
2-position
Single  Coil type
2 Double Nil Standard E: F:
3 Closed center T With power saving circuit (Continuous duty type) Push-turn Slide locking
4 3-position Exhaust center ∗ Be sure to select the power saving circuit type locking type
5 Pressure center when the valve is continuously energized for lever
A∗ N.C./N.C. long periods of time. type
4-position
B∗ dual 3-port
N.O./N.O. ∗ Be careful of the energizing time when the
power saving circuit is selected. Refer to page
C∗ N.C./N.O.
244 for details.
∗ Only rubber seal type is available for the ∗ Refer to page 14 for with the safety slide locking
4-position dual 3-port valve. manual override.
 Rated voltage
5 24 VDC
 Seal type  Type of mounting screw
0 Rubber seal Nil Round head combination screw
1 Metal seal  Light/surge voltage suppressor B Hexagon socket head cap screw
and common specification Round head combination screw
Surge voltage Common K (Falling-out-prevention type)
 Pilot type Symbol With light
suppressor specification Hexagon socket head cap screw
Nil Internal pilot H (Falling-out-prevention type)
R —
Non-polar
R External pilot U  ∗ For “K” and “H”, the valve body cover has a drop
S — Positive prevention construction to stop the mounting

Z  common screws from falling out when the valve is
 Back pressure check valve NS — Negative removed for maintenance etc.
(Built-in valve type) NZ  common ∗ When ordering a valve individually, the base
Nil None gasket is not included. Since the base gasket is
∗ Select a valve from R, U, S or Z when the SI unit attached to the manifold, please order the base
H Built-in specification is positive common. Select a valve gasket separately if it is needed for maintenance
∗ Only rubber seal type. Manifold installed type is from R, U, NS or NZ when the SI unit service.
available if the back pressure check valve is specification is ZBN (negative common). Refer to page 220 for part numbers of the base
required for a valve with metal seal. Refer to ∗ Only “Z” and “NZ” types are available for with gasket and mounting screw.
page 232 for Ordering Example. However, it is the power saving circuit. ∗ "B" and "H" cannot be selected for the individual
not recommended to use the built-in valve type SUP/EXH spacer assembly, interface regulator
and the manifold installed type at the same time or double check spacer assembly with residual
because it will reduce the flow. pressure release valve.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type and
the SY7000.

Protective class
class III (Mark: )

175
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY3000 Connector Connecting Base EX120

C2
U
SS5Y3-10S3- Stations D - C3,
C4, N3 (D)
N1

Sub-plate
B C6, N7

D side U side
Manual override Note 2)
(L5)
DIN rail holding screw L1
(
Push-turn locking slotted type:
)

Plug-in
(For DIN rail mounting) Press, then rotate it.
4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor) : Gray (For metal seal)
2(B) port side : Yellow

(5.5)
(8)
B A B A B A B A B A

Metal Base
(35)

92.6
14 A 14 A 14 A 14 A 14 A

64
83
6.2

60.5
(40.9)
12 B 12 B 12 B 12 B 12 B

M3

Plug-in
Terminal screw
16.1

4.6

1.7
4.6

)
(4.9)
C6: 3.6
N7: 7.4
4 x M4 mounting hole

27.9
( L2 1.5
(Fitting for the type with P/E
ports on the U and/or D sides)

Manifold Exploded View


(5.3) (L4)

Type 50, 51, 52


(DIN rail mounting hole pitch: 12.5)
(L3)
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø2
One-touch fitting
(Station 1) --- (Station n) : ø3.2, ø1/8"
[1(P), 3/5(E) port]
: ø4, ø5/32"
Applicable tube O.D.: ø8, ø5/16"
: ø6, ø1/4"

Connector Connecting Base


1 P 1 P

63.1
10.6
13.6

56.6
61

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

21.6

4 A4 A4 A4 A4 A
18

(For DIN rail


(7.5)

(Pitch)
mounting)
(11.8)

39.7 15.5 P = 10.5 (17.8)

Plug-in
Manifold Exploded View
Type 10, 11, 12
Note 1) These figures show the “SS5Y3-10S3V-05D-C6”.
Note 2) Refer to page 181 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 186 for dimensions of A or B port top-ported type.
Plug Assembly Part No.
One-touch Fittings/

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 96.9 107.4 117.9 128.4 138.9 149.4 159.9 170.4 180.9 191.4 201.9 212.4 222.9 233.4 243.9
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210
L3 123 135.5 148 160.5 173 173 185.5 198 210.5 223 235.5 235.5 248 260.5 273
Manifold Options

L4 112.5 125 137.5 150 162.5 162.5 175 187.5 200 212.5 225 225 237.5 250 262.5
L5 13 14 15 16 17 12 13 14 15 16 17 11.5 12.5 13.5 14.5

176
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000 Connector Connecting Base EX120

U C4, N3
SS5Y5-10S3- Stations D - C6, N7 (D)
B C8, N9

D side U side
Manual override Note 2)
(L5) L1
DIN rail holding screw
(For DIN rail mounting)
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
M3 DIN rail (Light/surge voltage suppressor) : Gray (For metal seal)
Terminal screw 2(B) port side : Yellow

(5.5)
(8)
6.2

BA BA BA BA BA

(35)
14 A 14 A 14 A 14 A 14 A
64
97.5

113.4
81.2
(61.7)
36.9

5.5
12 B 12 B 12 B 12 B 12 B
10.9

4.7
(5.9)
(8.3)

4 x M5 mounting hole

30.2 L2 1.5 (Fitting for the type with P/E


ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
One-touch fitting (Station 1) ----------- (Station n) : ø6, ø1/4"
: ø8, ø5/16"
[1(P), 3/5(E) port]
Applicable tube O.D.: ø10, ø3/8"

1 P 1 P
73.2

2 B2 B2 B2 B2 B
56.6
61

14.1

3/5 E 3/5 E
33.4

29.1

4 A4 A4 A4 A4 A
12.4
8.7

(For DIN rail


(7.5)

mounting)

(Pitch)
(11.8)

44.2 18 P = 16 (20.5)

Note 1) These figures show the “SS5Y5-10S3V-05D-C8”.


Note 2) Refer to page 182 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 187 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 116.7 132.7 148.7 164.7 180.7 196.7 212.7 228.7 244.7 260.7 276.7 292.7 308.7 324.7 340.7
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304
L3 148 160.5 173 198 210.5 223 248 260.5 273 285.5 310.5 323 335.5 348 373
L4 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5 275 300 312.5 325 337.5 362.5
L5 15.5 14 12 16.5 15 13 17.5 16 14 12.5 17 15 13.5 11.5 16

177
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY7000 Connector Connecting Base EX120

C6, N7
U
SS5Y7-10S3- Stations D - C8,
C10, N11 (D)
N9

Sub-plate
B C12

D side U side
Manual override Note 2)
(L5) L1
(Push-turn locking slotted type:
)

Plug-in
DIN rail holding screw Press, then rotate it.
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
(Light/surge voltage suppressor) : Gray (For metal seal)
2(B) port side: Yellow

(8)
(DIN rail)

B A B A B A B A B A

Metal Base
(35)
14 A 14 A 14 A 14 A 14 A
64
6.2

128.8
115
(5.5)

96.7
(77.1)

Plug-in
M3
50.8

12 B 12 B 12 B 12 B 12 B

5.5
Terminal screw

8.8
3.9
(6)

Manifold Exploded View


(9.3)

Type 50, 51, 52


(A, B port: ø12)
(17.9)

4 x M5 mounting hole

(Fitting for the type with P/E


28.9 L2 1.5 ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

Connector Connecting Base


(Station 1) (Station n)
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: ø12, ø1/2" 2

1 P 1 P
82.7

2 B2 B2 B2 B2 B
56.6
61

3/5 E 3/5 E
11.1

Plug-in
35.2

8.7

31.6

4 A4 A4 A4 A4 A
14.2

Manifold Exploded View


Type 10, 11, 12
(For DIN rail

(21.7)
(10)

mounting)
(14.3)

(Pitch)
47.7 20.5 P = 19
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
: ø10, ø3/8"
: ø12
Plug Assembly Part No.
One-touch Fittings/

Note 1) These figures show the “SS5Y7-10S3V-05D-C10”.


Note 2) Refer to page 183 for dimensions of external pilot, silencer, elbow fittings and slide locking manual override.
Note 3) Refer to page 188 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Manifold Options

L1 129.4 148.4 167.4 186.4 205.4 224.4 243.4 262.4 281.4 300.4 319.4 338.4 357.4 376.4 395.4
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360
L3 160.5 173 198 210.5 235.5 248 273 285.5 310.5 335.5 348 373 385.5 410.5 423
L4 150 162.5 187.5 200 225 237.5 262.5 275 300 325 337.5 362.5 375 400 412.5
L5 15.5 12.5 15.5 12 15 12 15 11.5 14.5 17.5 14.5 17.5 14 17 14

178
Plug-in Connector Connecting Base
EX120

Series SY3000/5000/7000
Type 12
Top Ported

RoHS
How to Order Manifold

Refer to pages 186 to 188


SS5Y 3 12S3 R1 05 U
for dimensions of Type
12/Top ported type.
      
 Series  Valve stations  P, E port entry
3 SY3000 Symbol Stations Note U Note) U side (2 to 10 stations)
5 SY5000 02 2 stations D Note) D side (2 to 10 stations)
7 SY7000 Double wiring Note 1) B Both sides (2 to 16 stations)
···

···

08 8 stations Note)  For type “S”, supply/exhaust block


02 2 stations assembly with built-in silencer, choose U or
 SI unit Specified layout Note 2) D for P port entry.
···

···

(Available up to 16 solenoids)
0 Without SI unit 16 16 stations
Q DeviceNet™ (Positive common NPN) Note 1) Double wiring: 2-position single, double,
R1 OMRON CompoBus/S 16 outputs 3-position and 4-position valves can be
 SUP/EXH block assembly
R2 (Positive common NPN) 8 outputs used on all manifold stations. Nil Internal pilot
V CC-Link (Positive common NPN) Use of a 2-position single solenoid will result S Internal pilot, Built-in silencer
in an unused control signal. If this is not R External pilot
ZB Note 2) Positive common NPN
desired, order with a specified layout.
CompoNet™
ZBN Note 2) Negative common PNP Note 2) Specified layout: Indicate the wiring ∗ For built-in silencer type, P and E ports are
Note 1) Ensure a match with the common specifications on the manifold specification available on U and D sides. 3/5(E) port is
specification of the valve to be used. sheet. (Note that 2-position double, plugged. The silencer exhaust port is located on
Note 2) The communication connector (for the 3-position and 4-position valves cannot be the opposite side of P, E port entry. (Example:
opposite side) is not provided. Please used where single wiring has been When the P, E port entry is D side, the silencer
order it separately. specified.) exhaust port is U side.)
Note 3) This also includes the number of blanking
plate assembly.
Note 4) Since R2 type SI unit has 8 outputs, note
that up to 8 solenoids can be
accommodated.
How to Order Manifold Assembly  P, E port size (One-touch fittings)
Symbol SY3000 SY5000 SY7000
Example (SS5Y3-12S3V-) Nil ø8 ø10 ø12
2-position double (24 VDC)
N ø5/16" ø3/8" ø1/2"
SY3230-5U1-C6 (1 set)
2-position single (24 VDC) ∗ For N, sizes are in inches.
SY3130-5U1-C6 (3 sets) 3-position closed
center (24 VDC)
SY3330-5U1-C6 (1 set)
 Mounting
Nil Direct mounting
D DIN rail mounting (With DIN rail)
D0 DIN rail mounting (Without DIN rail)
D3 For 3 stations Specify a longer rail
ide than the standard
Us
···

···

ati
on
s D16 For 16 stations length.
St
3 Note 1) When mounted on the DIN rail without the
2 SI unit, please select D0 and refer to L3 of
1
Manifold base the dimensions for the DIN rail length,
ide
(5 stations) Ds then order separately. (Refer to page 225
SS5Y3-12S3V-05D for the DIN rail part number.)
Note 2) Refer to page 247 for the fixation of DIN
SS5Y3-12S3V-05D ···1 set (Type 12 5-station manifold base part no.) rail mounting type manifold.
∗SY3130-5U1-C6 ·······3 sets (2-position single part no.)
∗SY3230-5U1-C6 ·······1 set (2-position double part no.)
∗SY3330-5U1-C6 ·······1 set (3-position closed center part no.)
The asterisk denotes the symbol for assembly.
For details about the EX120 Integrated-type (For Output) Serial
Prefix it to the part numbers of the valve etc.
Transmission System, refer to the WEB catalog or the Best
• The valve arrangement is numbered as the 1st station from the D side. Pneumatics No. 1 and the Operation Manual. For details about
• Under the manifold part number, state the valves to be mounted in order part numbers of SI units to be mounted, refer to page 218 in
from the 1st station as shown in the figure above. If the arrangement this catalog. Please download the Operation Manual via SMC
becomes complicated, specify on a manifold specification sheet. website, http://www.smcworld.com

179
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
            

Plug-in
Top ported

 Series  Pilot valve option  A, B port size


3 SY3000 Nil Standard (102 psi (0.7 MPa)) Thread piping
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Symbol Port size Applicable series
7 SY7000 K∗ High pressure type (145 psi (1.0 MPa)) M5 M5 x 0.8 SY3000
∗ Only metal seal type is available for the high 01 1/8 SY5000

Metal Base
pressure type. 02 1/4 SY7000
 Type of actuation One-touch fitting (Metric)
1 Single
2
2-position
Double
 Coil type Symbol A, B port SY3000 SY5000 SY7000
C2 ø2  — —
3 Closed center Nil Standard

Plug-in
C3 ø3.2  — —
4 3-position Exhaust center T With power saving circuit (Continuous duty type)
C4 ø4   —
5 Pressure center ∗ Be sure to select the power saving circuit type
C6 ø6   
A∗ N.C./N.C. when the valve is continuously energized for
C8 ø8 —  
4-position
B∗ dual 3-port
N.O./N.O. long periods of time.
C10 ø10 — —
∗ Be careful of the energizing time when the 
C∗ N.C./N.O.
C12

Manifold Exploded View


power saving circuit is selected. Refer to page ø12 — — 
∗ Only rubber seal type is available for the 244 for details.

Type 50, 51, 52


4-position dual 3-port valve. One-touch fitting (Inch)
Symbol A, B port SY3000 SY5000 SY7000
 Rated voltage N1 ø1/8"  — —
 Seal type 5 24 VDC N3 ø5/32"   —
0 Rubber seal N7 ø1/4"   
1 Metal seal N9 ø5/16" —  
 Light/surge voltage suppressor N11 ø3/8" — — 
and common specification

Connector Connecting Base


 Pilot type Symbol With light
Surge voltage Common
Nil Internal pilot
suppressor specification  Thread type
R External pilot R — Nil Rc
Non-polar
U  F G
S —

Positive N NPT
Z common T
 Back pressure check valve NS

— Negative
NPTF
(Built-in valve type) ∗ Only Nil is available for M5.
NZ  common
Nil None

Plug-in
∗ Select a valve from R, U, S or Z when the SI unit
H Built-in
∗ Only rubber seal type. Manifold installed type is
specification is positive common. Select a valve
from R, U, NS or NZ when the SI unit
 Type of mounting screw
available if the back pressure check valve is specification is ZBN (negative common). Nil Round head combination screw

Manifold Exploded View


required for a valve with metal seal. Refer to ∗ Only “Z” and “NZ” types are available for with B Hexagon socket head cap screw

Type 10, 11, 12


page 232 for Ordering Example. However, it is the power saving circuit. Round head combination screw
not recommended to use the built-in valve type K (Falling-out-prevention type)
and the manifold installed type at the same time Hexagon socket head cap screw
because it will reduce the flow.  Manual override H (Falling-out-prevention type)
∗ The built-in valve type back pressure check
valve is not available for the 3-position type and Nil: D:
the SY7000. Non-locking Push-turn ∗ For “K” and “H”, the valve body cover has a drop
push type locking slotted prevention construction to stop the mounting
type screws from falling out when the valve is
removed for maintenance etc.
Plug Assembly Part No.

∗ When ordering a valve individually, the base


One-touch Fittings/

gasket is not included. Since the base gasket is


attached to the manifold, please order the base
gasket separately if it is needed for maintenance
E: F: service.
Push-turn Slide locking Refer to page 220 for part numbers of the base
locking lever type gasket and mounting screw.
type ∗ “B” and “H” cannot be selected for the individual
Manifold Options

SUP/EXH spacer assembly or interface


regulator.

∗ Refer to page 14 for with the safety slide locking Protective class
manual override. class III (Mark: )

180
Series SY3000/5000/7000
Common Dimensions
Plug-in Type 10/Side Ported

Series SY3000 Connector Connecting Base External Pilot, Silencer, Elbow Fittings, Slide Locking Manual Override

U
SS5Y3-10- Stations D (S, R)- LB D side U side
B
One-touch fitting 7.4 85.5
[PE: Pilot EXH port] (For 5 stations)
[X: External pilot port]
(73.2) (7.4) (11.6)
Applicable tube O.D.: ø4, ø5/32"
(Fitting for the type with P/E
ports on the U and/or D sides)

5.3
PE PE
LOCK

X X
3/5E B A B A B A B A B A 3/5E
14 A 14 A 14 A 14 A 14 A

(127.8)
58.5
FREE

40.9
1P 1P
12 B 12 B 12 B 12 B 12 B

11.6

6.9
1.7

17.3
27.6
35.2

2(B) port (Fitting for the type with P/E


ports on the U and/or D sides)
70.6 1(P) port 4(A) port
3/5(E) port
One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: ø4, ø5/32"
Applicable tube O.D.: ø8, ø5/16" : ø6, ø1/4"
External pilot for straight piping (Station 1) --- (Station n)
P, E port entry: D

7.4 85.5

manual override)
(Slide locking
(For 5 stations) 1 P
(65.4)

68.8
63.1
56.6
(43.2)

3/5 E

PE
LOCK

X
B A B A B
14 A 14 A 14

)
)
L6 : 32.4
LN7 : 34.9
L6 : 43.4
LN7 : 45.9
(Pitch)
FREE

(42.8)
(37.5)

1P
12 B 12 B
15.5 P= 10.5 (17.8)
(
78.6 One-touch fitting
Note) These figures show the “SS5Y3-10F2-05DR-L6”. (
82.3 [PE: Pilot EXH port]
[X: External pilot port]
Applicable tube O.D.: ø4, ø5/32"

Built-in silencer Downward (Type B)


<Internal pilot>
[SUP/EXH block] [Valve]
P, E port entry: D

Silencer (Exhaust port)


(Built-in silencer specification)
LOCK

LOCK
FREE

FREE
LOCK

B A B A B (11.2)
14 A 14 A 14

4(A) port
3/5(E) port
FREE

12 B 12 B
2(B) port

1(P) port
(0.2)
(7.2) (15)
Plug
3/5(E) port

181
Common Dimensions Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Series SY5000 Connector Connecting Base External Pilot, Silencer, Elbow Fittings, Slide Locking Manual Override

U One-touch fitting D side U side


SS5Y5-10- Stations D (S, R)- LB [PE: Pilot EXH port] 118.2

Sub-plate
B
[X: External pilot port] (For 5 stations)
(65.4) (12)
Applicable tube O.D.: ø4, ø5/32"
(Fitting for the type with P/E
ports on the U and/or D sides)

Plug-in
PE PE

LOCK
3/5 B A B A B A B A B A 3/5
14 A 14 A 14 A 14 A 14 A

26.9
113.4
E E
FREE

X X
1 1

(159.5)

61.7
P P

52.8
12 B 12 B 12 B 12 B 12 B

4.7
12.6
17.9

Metal Base
28.6
36.9
(Fitting for the type with P/E
2(B) port ports on the U and/or D sides)

Plug-in
1(P) port
External pilot for straight piping 4(A) port One-touch fitting
(118.2) 3/5(E) port [4(A), 2(B) port]
P, E port entry: D
(For 5 stations) One-touch fitting Applicable tube O.D.: ø4
(20°) : ø6, ø1/4"
[1(P), 3/5(E) port]
Applicable tube O.D.: ø10, ø3/8" : ø8, ø5/16"

Manifold Exploded View


(Station 1) ----------- (Station n)

Type 50, 51, 52


PE
LOCK

3/5 BA BA
14 A 14 A

E
X
FREE

manual override)
(59.8)

(Slide locking
P
(31.7)

12 B 12 B 12 B

78.9
1 P
66.1
(59.8)

(54.3)
(39.3)
(38.8)

3/5 E
70.8 One-touch fitting

Connector Connecting Base


4 A4 A4 A4 A4 A
74.5 [PE: Pilot EXH port]
[X: External pilot port]
Applicable tube O.D.: ø4, ø5/32" (Pitch)
18 P = 16 (20.5)
Built-in silencer
P, E port entry: D
Silencer (Exhaust port)
(Built-in silencer specification) Note) These figures show the “SS5Y5-10F2-05DR-L8”.

Plug-in
LOCK

BA BA
14 A 14 A
FREE

Manifold Exploded View


Type 10, 11, 12
12 B 12 B 12 B

Valve/Series SY3000 (Mixed Mounting)


Plug
3/5(E) port Downward (Type B) Upward (Type U)

Downward (Type B)
[SUP/EXH block] [Valve]
Plug Assembly Part No.
LOCK

LOCK

One-touch Fittings/

One-touch fitting
[4(A), 2(B) port]
LOCK

LOCK

FREE

FREE

( )
B6 : 10.7 Applicable tube O.D.: ø4, ø5/32"
BN7 : 13.2 : ø6, ø1/4"
FREE

FREE

6.5

16.9

Manifold Options

4(A) port

2(B) port ( L6 : 32.9


LN7 : 35.4 )
( B6 : 9.7
)
(14) (7)
(11.1) (3.9)
BN7 : 7.2
( L6 : 53.3
LN7 : 55.8 )
182
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Series SY7000 Connector Connecting Base External Pilot, Silencer, Elbow Fittings, Slide Locking Manual Override

U
SS5Y7-10- Stations D (S, R)- LB One-touch fitting
[PE: Pilot EXH port]
D side U side
B 138.1
[X: External pilot port]
(69.5) (For 5 stations) (10.9)
Applicable tube O.D.: ø6, ø1/4"
(Fitting for the type with P/E
ports on the U and/or D sides)

PE PE
LOCK

3/5E B A B A B A B A B A 3/5E
14 A 14 A 14 A 14 A 14 A

49.4
128.8
FREE

(175.6)
1P 1P

(77.1)
X X

45.4
12 B 12 B 12 B 12 B 12 B

15.6
3.9

34.6
37.6
16.6
(Fitting for the type with P/E
1(P) port ports on the U and/or D sides)
3/5(E) port One-touch fitting
External pilot for straight piping One-touch fitting 4(A) port [4(A), 2(B) port]
P, E port entry: D Applicable tube O.D.: ø12
[1(P), 3/5(E) port] 2(B) port
(138.1) Applicable tube O.D.: ø12, ø1/2"
One-touch fitting
(For 5 stations) [4(A), 2(B) port]
(20°) Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
: ø10, ø3/8"
(Station 1) (Station n)

(Slide locking manual override)


PE
LOCK

3/5E B A B A
14 A 14 A
FREE

85.8
1 P
(For ø10, ø3/8")

(For ø12)
69.7
(53.1)

(58)
(For ø12)
1P
(For ø10, ø3/8")
(74.2)
(23.5)

(37.5)
3/5 E
(32.6)

12 B 12 B

20.5 (Pitch) (21.7)


77.7 One-touch fitting P = 19
82.7 [PE: Pilot EXH port]
[X: External pilot port]
Applicable tube O.D.: ø6, ø1/4"
Note) These figures show the “SS5Y7-10F2-05DR-LM”.
Built-in silencer
P, E port entry: D Downward (Type B)
[SUP/EXH block] [Valve]
Silencer (Exhaust port)
(Built-in silencer specification)
LOCK

LOCK
LOCK

B A B A
FREE

FREE

14 A 14 A
FREE

12 B 12 B

3/5(E) port 4(A) port


Plug 2(B) port
3/5(E) port 1(P) port
(7.3) (13.7) ( ø10: 15.3
ø12: 10.4 ) ( ø10: 5.2
ø12: 10.1 )
183
Common Dimensions Series SY3000/5000/7000

Valve
Plug-in Type 11/Bottom Ported

Series SY5000 Connector Connecting Base All Wirings

U
SS5Y5-11- Stations D

Sub-plate
B D side U side
L2 1.5 Manual override

(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)

Plug-in
: Gray (For metal seal)
2(B) port side : Yellow

4 x M5 mounting hole

LOCK
BA BA BA BA B A
14 A 14 A 14 A 14 A 14 A

97.5
113.4
FREE

Metal Base
5.5
12 B 12 B 12 B 12 B 12 B

10.9

Plug-in
4.7
External pilot
P, E port entry: D (118.2) (Station 1) ---------- (Station n)
(For 5 stations)
(20°)

manual override)
(Slide locking

Manifold Exploded View


78.9
73.2

Type 50, 51, 52


PE
LOCK

3/5 B A B A

8.7
14 A 14 A

4.7
E
FREE

X
1
(59.8)

(12.9)

(9.5)
P
12 B 12 B 12 B
(Fitting for the type with P/E
(31.7)

ports on the U and/or D sides)

Connector Connecting Base


120.5
70.8 One-touch fitting
(For 5 stations)
74.5 [PE: Pilot EXH port]
[X: External pilot port] (Pitch)
Applicable tube O.D.: ø4, ø5/32" 18 P = 16 (20.5)
4.7

Built-in silencer
31.8

P, E port entry: D
39.7

Silencer (Exhaust port) 3/5 E 3/5 E


(Built-in silencer specification) 2 B2 B2 B2 B2 B
18

Plug-in
15

1 P 1 P
4 A4 A4 A4 A4 A

Fitting dimensions for panel mounting


LOCK

Manifold Exploded View


BA BA
14 A 14 A Refer to panel fitting dimensions

Type 10, 11, 12


for details.
FREE

One-touch fitting One-touch fitting


12 B 12 B 12 B [1(P), 3/5(E) port] [4(A), 2(B) port]
Applicable tube O.D.: ø10, ø3/8" Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"
Plug Note 1) These figures show the “SS5Y5-11F2-05D-C8”.
Note 2) Refer to the below pages for L2 dimensions and other dimensions
Plug Assembly Part No.

that are not specified in each wiring specification.


One-touch Fittings/

Panel fitting dimensions D-sub connector <IP40> : P. 85


D-sub connector <IP67> : P. 88
Flat ribbon cable : P. 91
7

Terminal block box : P. 103


Lead wire : P. 113
Circular connector : P. 123
60

EX500 : P. 133
Manifold Options
97.5

EX600 : P. 142, 143


EX250 : P. 153
EX260 : P. 161
EX126 : P. 169
EX120 : P. 177
L2 4 x M5 mounting hole
4 x ø5.5
184
Series SY3000/5000/7000

Plug-in Type 11/Bottom Ported

Series SY7000 Connector Connecting Base All Wirings

U L2 1.5
SS5Y7-11- Stations D D side U side
Manual override
B
( Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side:
Blue (For rubber seal)
Gray (For metal seal)
2(B) port side : Yellow

LOCK
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A

115
FREE

12 B 12 B 12 B 12 B 12 B

5.5
8.8
External pilot
P, E port entry: D (138.1) 4 x M5 mounting hole
(For 5 stations)
40.1 (20°) (Station 1) (Station n)

(Slide locking manual override)


2
PE
LOCK

3/5E B A B A

85.8
82.7
14 A 14 A

56.6
FREE

8.7
1P
(74.2)

12 B 12 B

9.1
(12)
(14.5)
(23.5)

X
(23.9)

(A, B port: ø12) (Fitting for the type with P/E


One-touch fitting ports on the U and/or D sides)
77.7 117
[PE: Pilot EXH port] (For 5 stations)
82.7
[X: External pilot port]
Applicable tube O.D.: ø6, ø1/4" (Pitch)
39.5 20.5 P = 19 (21.7)
3.9

Built-in silencer
P, E port entry: D
Silencer (Exhaust port)
39.9

(Built-in silencer specification)


48.7

3/5 E 3/5 E

2 B2 B2 B2 B2 B
21

19.5
LOCK

B A B A 4 A4 A4 A4 A4 A
14 A 14 A
1 P 1 P
FREE

Fitting dimensions for panel mounting


Refer to panel fitting dimensions
for details.
Plug
12 B 12 B

One-touch fitting One-touch fitting


[1(P), 3/5(E) port] [4(A), 2(B) port]
Applicable tube O.D.: ø12, ø1/2" Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
: ø10, ø3/8"
Panel fitting dimensions : ø12
Note 1) These figures show the “SS5Y7-11F2-05D-C10”.
16

Note 2) Refer to the below pages for L2 dimensions and other dimensions
that are not specified in each wiring specification.
D-sub connector <IP40> : P. 86
D-sub connector <IP67> : P. 89
60

Flat ribbon cable : P. 92


115

Terminal block box : P. 104


Lead wire : P. 114
Circular connector : P. 124
EX500 : P. 134
EX600 : P. 144, 145
EX250 : P. 154
4 x M5 EX260 : P. 162
L2 mounting hole
4 x ø5.5 EX126 : P. 170
185 EX120 : P. 178
Common Dimensions Series SY3000/5000/7000

Valve
Plug-in Type 12/Top Ported

Series SY3000 Connector Connecting Base All Wirings

U
SS5Y3-12- Stations D (R)
B

Sub-plate
D side U side
89.3
(For 5 stations) Light/surge voltage suppressor

One-touch fitting (External pilot) (Pitch) Manual override

Plug-in
[PE: Pilot EXH port]
[X: External pilot port]
7.4
16 P = 10.5
(15.3)
(
Push-turn locking slotted type:
Press, then rotate it. )
Applicable tube O.D.: ø4, ø5/32" 4(A) port side : Blue (For rubber seal)
(73.2) : Gray (For metal seal)
2(B) port side : Yellow

5.3 PE PE
LOCK

X X

Metal Base
3/5E B A B A B A B A B A 3/5E

92.6
4A 4A 4A 4A 4A
15

11

60.5
58.5
FREE
(40.9)

1P 1P
31.8

30.2
2B 2B 2B 2B 2B

Plug-in
1.7
One-touch fitting

(A/B port, side ported)


[1(P), 3/5(E) port]
(Fitting for the type with P/E
Applicable tube O.D.: ø8, ø5/16"
ports on the U and/or D sides)

) C6: 3.6
N7: 7.4
M5 x 0.8

Manifold Exploded View


One-touch fitting

Type 50, 51, 52


[4(A), 2(B) port] (
[4(A), 2(B) port]
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
: ø6, ø1/4"

(Station 1) --- (Station n)

Connector Connecting Base


)C6: 77.3
N7: 81.1

1 P 1 P
(73.8)

3/5 E 2 B2 B2 B2 B2 B 3/5 E
(

4 A4 A4 A4 A4 A

Plug-in
Manifold Exploded View
Note 1) These figures show the “SS5Y3-12F2-05D”.

Type 10, 11, 12


Note 2) For built-in silencer type, a silencer is mounted on the opposite side of U or D side with P or E port.
Refer to page 181 for dimensions of silencer.
Note 3) Refer to the below pages for dimensions that are not specified in each wiring specification.
D-sub connector <IP40> : P. 84
D-sub connector <IP67> : P. 87
Flat ribbon cable : P. 90
Terminal block box : P. 102
Lead wire : P. 112
Circular connector : P. 122
Plug Assembly Part No.

EX500 : P. 132
One-touch Fittings/

EX600 : P. 140, 141


EX250 : P. 152
EX260 : P. 160
EX126 : P. 168
EX120 : P. 176
Manifold Options

186
Series SY3000/5000/7000
Plug-in Type 12/Top Ported

Series SY5000 Connector Connecting Base All Wirings

U
SS5Y5-12- Stations D (R)
B
D side U side
Light/surge voltage suppressor
123.6
(For 5 stations)

(Pitch) Manual override


78.9
(Slide locking
manual override)
5.4
21.1 P = 16 (17.4)
(5.4)
(
Push-turn locking slotted type:
Press, then rotate it. )
One-touch fitting (External pilot) 4(A) port side : Blue (For rubber seal)
(65.4) [PE: Pilot EXH port] : Gray (For metal seal)
[X: External pilot port] 2(B) port side : Yellow
Applicable tube O.D.: ø4, ø5/32"
26.5

PE PE
LOCK

BA BA BA BA B A
3/5 3/5
4A 4A 4A 4A 4A
26.9

113.4
116.7
E E
X X
FREE

1 1

81.2
(61.7)

01 : 16.2
C : 14.5
P P
52.8

47.3
39.5

2B 2B 2B 2B 2B

One-touch fitting (Fitting for the type with P/E


2.7
4.7

[1(P), 3/5(E) port] ports on the U and/or D sides)


Applicable tube O.D.: ø10, ø3/8" 1/8
[4(A), 2(B) port] One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"
: ø8, ø5/16"

(Station 1) ----------- (Station n) (91.3)

1 P 1 P
76.9
(69.7)

2 B2 B2 B2 B2 B

3/5 E 3/5 E

4 A4 A4 A4 A4 A

Note 1) These figures show the “SS5Y5-12F2-05D”.


Note 2) For built-in silencer type, a silencer is mounted on the opposite side of U or D side with P or E port.
Refer to page 182 for dimensions of silencer.
Note 3) Refer to the below pages for dimensions that are not specified in each wiring specification.
D-sub connector <IP40> : P. 85
D-sub connector <IP67> : P. 88
Flat ribbon cable : P. 91
Terminal block box : P. 103
Lead wire : P. 113
Circular connector : P. 123
EX500 : P. 133
EX600 : P. 142, 143
EX250 : P. 153
EX260 : P. 161
EX126 : P. 169
EX120 : P. 177

187
Common Dimensions Series SY3000/5000/7000

Valve
Plug-in Type 12/Top Ported

Series SY7000 Connector Connecting Base All Wirings

U
SS5Y7-12- Stations D (R)

Sub-plate
B

One-touch fitting
(External pilot) D side U side
[PE: Pilot EXH port] (Light/surge voltage suppressor)

Plug-in
[X: External pilot port]
144.3 Manual override
Applicable tube O.D.: ø6, ø1/4"
85.8
(Slide locking manual override)
(Pitch)
26.1 P = 19
(For 5 stations)
(17.1)
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
(69.5) 6.2 (6.2) : Gray (For metal seal)
2(B) port side: Yellow

Metal Base
PE PE
LOCK

3/5E B A B A B A B A B A 3/5E
4A 4A 4A 4A 4A
(49.4)
21

128.8
133.2
FREE

22.6

Plug-in
96.7
1P 1P
(77.1)

X X
59.9
(45.5)

46.4
2B 2B 2B 2B 2B

Manifold Exploded View


Type 50, 51, 52
One-touch fitting 1/4 4 x M5 mounting hole
2.4
3.9

[1(P), 3/5(E) port] [4(A), 2(B) port] One-touch fitting


Applicable tube O.D.: ø12, ø1/2"
[4(A), 2(B) port]
Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16"
(Station 1) (Station n) : ø10, ø3/8"
: ø12
(A, B port: ø12)
(Fitting for the type with P/E

Connector Connecting Base


ports on the U and/or D sides)

(112.1)
(100.3)
88.8

1 P 1 P
(75.1)

2 B2 B2 B2 B2 B

Plug-in
3/5 E 3/5 E
8.7

4 A4 A4 A4 A4 A

Manifold Exploded View


Type 10, 11, 12
(10)

(For DIN rail


mounting)
(14.3)

Note 1) These figures show the “SS5Y7-12F2-05D”.


Note 2) For built-in silencer type, a silencer is mounted on the opposite side of U or D side with P or E port.
Plug Assembly Part No.
One-touch Fittings/

Refer to page 183 for dimensions of silencer.


Note 3) Refer to the below pages for dimensions that are not specified in each wiring specification.
D-sub connector <IP40> : P. 86
D-sub connector <IP67> : P. 89
Flat ribbon cable : P. 92
Terminal block box : P. 104
Lead wire : P. 114
Manifold Options

Circular connector : P. 124


EX500 : P. 134
EX600 : P. 144, 145
EX250 : P. 154
EX260 : P. 162
EX126 : P. 170
EX120 : P. 178
188
Plug-in Connector Connecting Base: Plug-in Mixed Mounting Type Manifold
Type 10
D-sub Connector (IP40/67) Flat Ribbon Cable PC Wiring Terminal Block Box (IP67) Lead Wire (IP67)
Side Ported
Circular Connector (IP67) EX500 (IP67) EX600 (IP67) EX250 (IP67) EX260 (IP67) EX126 (IP67) EX120

Series SY3000/5000
Type 11
Bottom Ported

The SY3000 can be mounted onto the


SY5000 size manifold. How to Order Manifold
Refer to page 198 for
dimensions of Type
11/Bottom ported type.
SS5Y5 M 10 F 1 05 U C 8 6
Mixed Mounting Type
It is possible to mount the SY3000 size valves on all stations.
         
In this case, there is no need to fill in part in the order code.
However, the manifold block width should be 12.5 mm.

 Type  Valve stations  SUP/EXH block assembly


10 Side ported Symbol Stations Note Nil Internal pilot
11 Bottom ported 02 2 stations Some connectors have a limitation Internal pilot,
on the number of stations. Refer to S Built-in silencer
···

···

the pages shown in the table


24 R External pilot
 Connector type 24 stations “Connector type” for details.
∗ 3/5(E) port is plugged for the built-in silencer type.
Connector
Symbol type Type Page ∗ Refer to page 137 for the EX600 and  on page
F D-sub connector IP40  P, E port entry 149 for the EX250.
FW (25 pins) IP67
U U side (2 to 10 stations)
P 26 pins
D D side (2 to 10 stations)
PG Flat ribbon cable 20 pins 81
B Both sides (2 to 24 stations)
PH 10 pins
∗ Refer to page 137 for the EX600 and  on page
J PC wiring

149 for the EX250.
With power
G (20 pins)
supply terminal
T Terminal block box 99  Fitting type: One-touch fitting
L1 34 cores Symbol A, B port
L2 Lead wire 17 cores 109 C Straight
L3 9 cores L Metric size Upward Note)
M Circular connector 119 Elbow
B Downward Note)
S EX500 129 N Straight
S6 EX600 137 LN Inch size Upward Note)
S Serial EX250 149 Elbow
BN Downward Note)
transmission
S EX260 157 CM∗ Straight
Mixed sizes
S4 EX126 165 LM∗ Elbow (Including upward and downward piping) Note)
S3 EX120 173 Note) To avoid interference with the body or piping, select downward elbow port
∗ Refer to the pages shown in the table above for details. when mounting the optional spacer assembly (pages 226 to 228). Elbow
fittings are not available for Type 11 (Bottom ported).
 ∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”,
• With Lead wire indicate it on the manifold specification sheet for the P, E port fitting direction.
∗ Elbow fittings: ø2, ø3.2 and ø1.8" are not available for the SY3000 series. ø2,
Lead wire length ø3.2, ø1.8" and ø5/32" are not available for the SY5000 series.
1 0.6 m
2 1.5 m
3 3m

• With D-sub connector (IP40/67), Flat


ribbon cable and PC wiring
Connector entry direction
1 Upward
2 Lateral

∗ It is not necessary to select the items above for the


valve with terminal block box or with circular
connector or the serial transmission type.

189
Plug-in Connector Connecting Base Series SY3000/5000

Valve
Sub-plate
 SY5000: A, B port size  Mounting

Plug-in
(Metric/One-touch fitting) (Inch/One-touch fitting) Nil Direct mounting
Symbol Port size Symbol Port size D DIN rail mounting (With DIN rail)
4 ø4 3 ø5/32" D0 DIN rail mounting (Without DIN rail)
6 ø6 7 ø1/4" D3 For 3 stations Specify a longer rail than the standard length.
8 ø8 9 ø5/16" [The SY5000 valve is now at a mountable length

···

···
Nil For all stations of SY3000 Nil For all stations of SY3000 D24 For 24 stations (manifold block length of 16 mm).]
∗ No symbol needs to be specified when fitting type “CM”, “LM” is selected. Note 1) Only direct mounting is available for Type 11 (Bottom ported).

Metal Base
Note 2) Refer to page 196 to determine the L3 using “Calculation formula” for
the DIN rail length.
Note 3) Refer to page 247 for the fixation of DIN rail mounting type manifold.
 SY3000: A, B port size
(Metric/One-touch fitting) (Inch/One-touch fitting)

Plug-in
Symbol Port size Symbol Port size
2 ø2 1 ø1/8"
3 ø3.2 3 ø5/32"
4 ø4 7 ø1/4"
6 ø6 9 ø5/16" Note)

Manifold Exploded View


8 ø8 Note)

Type 50, 51, 52


Note) The valve pitch is the same as the SY5000.
∗ No symbol needs to be specified when fitting type “CM”, “LM” is selected.

How to Order Manifold Assembly

Connector Connecting Base


Example (SS5Y5-M10F1-)
2-position double
2-position double SY3200-5U1 (2 sets)
SY5200-5U1 (3 sets) Manifold base (5 stations)
SS5Y5-M10F1-05D-C86

Plug-in
Manifold Exploded View
ide

Type 10, 11, 12


Us
s
on
ati
St
3
2
1
ide
Ds

SS5Y5-M10F1-05D-C86 ···1 set (Type M10 5-station manifold base part no.)
∗SY5200-5U1 ·····················3 sets (2-position double part no.)
Plug Assembly Part No.
One-touch Fittings/

∗SY3200-5U1 ·····················2 sets (2-position double part no.)


The asterisk denotes the symbol for assembly.
Prefix it to the part numbers of the valve etc.
• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order from
the 1st station as shown in the figure above. If the arrangement becomes
Manifold Options

complicated, specify on a manifold specification sheet.


Note) When mixing top ported configurations, select from page 202.
In this case, use caution as there is also output on the A and B port on base
side.
Specify on a manifold specification sheet if plugs are required on the A and B
Protective class
port on base side. class III (Mark: )

190
Series SY3000/5000

How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 0 0 5 1
          
Base mounted

 Series  Pilot valve option  Manual override


3 SY3000 Nil Standard (102 psi (0.7 MPa)) Nil: D:
5 SY5000 B Quick response type (102 psi (0.7 MPa)) Non-locking Push-turn
K∗ High pressure type (145 psi (1.0 MPa)) push type locking
∗ Only metal seal type is available for the high slotted
pressure type. type
 Type of actuation
1 Single
2
2-position
Double  Coil type
E: F:
3 Closed center Nil Standard Push-turn Slide locking
4 3-position Exhaust center T With power saving circuit (Continuous duty type) locking type
5 Pressure center ∗ Be sure to select the power saving circuit type lever
A∗ N.C./N.C. when the valve is continuously energized for type
4-position
B∗ dual 3-port
N.O./N.O. long periods of time.
C∗ N.C./N.O. ∗ Be careful of the energizing time when the
power saving circuit is selected. Refer to page
∗ Only rubber seal type is available for the 244 for details. ∗ Refer to page 14 for with the safety slide locking
4-position dual 3-port valve. manual override.

 Rated voltage
 Seal type 5 24 VDC  Type of mounting screw
0 Rubber seal 6 12 VDC Nil Round head combination screw
1 Metal seal ∗ Only 24 VDC is available for the serial B Hexagon socket head cap screw
transmission type. Round head combination screw
K (Falling-out-prevention type)
Hexagon socket head cap screw
 Pilot type  Light/surge voltage suppressor H (Falling-out-prevention type)
Nil Internal pilot and common specification ∗ For “K” and “H”, the valve body cover has a drop
R External pilot Symbol With light
Surge voltage Common prevention construction to stop the mounting
suppressor specification screws from falling out when the valve is
Nil — — removed for maintenance etc.
∗ When ordering a valve individually, the base
R — Non-polar
 Back pressure check valve U 
gasket is not included. Since the base gasket is
attached to the manifold, please order the base
(Built-in valve type) S — Positive
 gasket separately if it is needed for maintenance
Nil None Z  common service.
H Built-in NS — Negative Refer to page 220 for part numbers of the base
∗ Only rubber seal type. Manifold installed type is NZ  common gasket and mounting screw.
available if back pressure check valve is ∗ “B” and “H” cannot be selected for the individual
∗ “Nil” is not available for the SI unit manifold. SUP/EXH spacer assembly, interface regulator
required for the valve with metal seal. Refer to ∗ Only “Z” and “NZ” types are available for with
page 232 for Ordering Example. However, it is or double check spacer assembly with residual
the power saving circuit. Select a valve which is pressure release valve.
not recommended to use the built-in valve type suited to the SI unit output polarity or SI unit
and the manifold installed type at the same time specification when the SI unit is selected.
because it will reduce the flow. Refer to the pages below for details.
∗ The built-in valve type back pressure check EX500: P. 131 EX600: P. 139 EX250: P. 151
valve is not available for the 3-position type. EX260: P. 159 EX126: P. 167 EX120: P. 175

Protective class
class III (Mark: )

191
192
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Type 10 Plug-in Connector Connecting Base: Plug-in Mixed Mounting Type Manifold
D-sub Connector (IP40/67) Flat Ribbon Cable PC Wiring Terminal Block Box (IP67) Lead Wire (IP67)
Side Ported Circular Connector (IP67) EX500 (IP67) EX600 (IP67) EX250 (IP67) EX260 (IP67) EX126 (IP67) EX120

Series SY5000/7000
Type 11
Bottom Ported

The SY5000 can be mounted onto the


SY7000 size manifold. How to Order Manifold
Refer to page 199 for
dimensions of Type
11/Bottom ported type.
SS5Y7 M 10 F 1 05 U C 10 8
Mixed Mounting Type          
It is possible to mount the SY5000 size valves on all stations.
In this case, there is no need to fill in part in the order code.
However, the manifold block width should be 19 mm.

 Type  Valve stations  SUP/EXH block assembly


10 Side ported Symbol Stations Note Nil Internal pilot
11 Bottom ported 02 2 stations Some connectors have a limitation Internal pilot,
on the number of stations. Refer to S Built-in silencer
···

···

the pages shown in the table


24 R External pilot
 Connector type 24 stations “Connector type” for details.
∗ 3/5(E) port is plugged for the built-in silencer
Connector
Symbol type Type Page type.
F D-sub connector IP40  P, E port entry ∗ Refer to page 137 for the EX600 and  on page
FW (25 pins) IP67 149 for the EX250.
U U side (2 to 10 stations)
P 26 pins
D D side (2 to 10 stations)
PG Flat ribbon cable 20 pins 81
B Both sides (2 to 24 stations)
PH 10 pins
∗ Refer to page 137 for the EX600 and  on page
J PC wiring —
149 for the EX250.
G (20 pins) With power supply terminal
T Terminal block box 99
L1 34 cores  Fitting type: One-touch fitting
L2 Lead wire 17 cores 109 Symbol A, B port
L3 9 cores C Straight
M Circular connector 119 L Metric size Upward Note)
Elbow
S EX500 129 B Downward Note)
S6 EX600 137 N Straight
S Serial EX250 149 LN Inch size Upward Note)
Elbow
S transmission EX260 157 BN Downward Note)
S4 EX126 165 CM∗ Straight
Mixed sizes
S3 EX120 173 LM∗ Elbow (Including upward and downward piping) Note)
∗ Refer to the pages shown in the table above for Note) To avoid interference with the body or piping, select downward elbow port
details. when mounting the optional spacer assembly (pages 226 to 228). Elbow
fittings are not available for Type 11 (Bottom ported).
 ∗ Indicate the sizes on the manifold specification sheet in the case of “CM”, “LM”.
∗ The direction of P, E port fittings is the same as for A, B port. If selecting “LM”,
• With Lead wire indicate it on the manifold specification sheet for the P, E port fitting direction.
∗ Elbow fittings: ø1/4" and ø5/16" are not available.
Lead wire length
1 0.6 m
2 1.5 m
3 3m

• With D-sub connector (IP40/67), Flat


ribbon cable and PC wiring
Connector entry direction
1 Upward
2 Lateral

∗ It is not necessary to select the items above for


the valve with terminal block box or with circular
connector or the serial transmission type.

193
Plug-in Connector Connecting Base Series SY5000/7000

Valve
 SY7000: A, B port size  Mounting and Option

Sub-plate
(Metric/One-touch fitting) (Inch/One-touch fitting) Option DIN Rail Option
Symbol Mounting
Symbol Port size Symbol Port size Name plate Station number Nil Direct mounting
6 ø6 7 ø1/4" Nil — — 0 Without DIN rail (with bracket)
Direct

Plug-in
8 ø8 9 ø5/16" AA mounting
  3 For 3 stations Specify a longer
10 ø10 11 ø3/8" BA  — rail than the total

···

···
D — — length of
12 ø12 Nil For all stations of SY5000
A
DIN rail 24 For 24 stations specified stations.
Nil For all stations of SY5000 mounting  
∗ No symbol needs to be specified when fitting type “CM”, “LM” is selected. B  —
Note 1) Enter the number of stations inside  when it is larger than the
number of valve stations. (Refer to “DIN Rail Option” above.)
Note 2) Only direct mounting is available for Type 11 (Bottom ported).
 SY5000: A, B port size

Metal Base
Note 3) Refer to page 196 to determine the L3 using “Calculation formula” for
(Metric/One-touch fitting) (Inch/One-touch fitting) the DIN rail length. (For the SY3000 and SY5000 mixed mounting
Symbol Port size Symbol Port size type)
6 ø6 7 ø1/4" Note 4) The manifold block width is 19 mm for both the SY5000 and SY7000
8 sizes.
ø8 9 ø5/16"
Note 5) Refer to page 247 for the fixation of DIN rail mounting type manifold.

Plug-in
10 ø10 11 ø3/8"
12 ø12
Note) The valve pitch is 19 mm, the same as the SY7000.
∗ No symbol needs to be specified when fitting type “CM”, “LM” is selected.

Manifold Exploded View


Type 50, 51, 52
How to Order Manifold Assembly

Example (SS5Y7-M10F1-)

Connector Connecting Base


2-position double
SY5200-5U1 (2 sets)
2-position double
SY7200-5U1 (3 sets) Manifold base (5 stations)
SS5Y7-M10F1-05D-C128

Plug-in
ide
Us
s
on

Manifold Exploded View


ati
St

Type 10, 11, 12


3
2
1
ide
Ds

SS5Y7-M10F1-05D-C128 ··1 set (Type M10 5-station manifold base part no.)
∗SY7200-5U1 ·····················3 sets (2-position double part no.)
∗SY5200-5U1 ·····················2 sets (2-position double part no.)
The asterisk denotes the symbol for assembly.
Plug Assembly Part No.

Prefix it to the part numbers of the valve etc.


One-touch Fittings/

• The valve arrangement is numbered as the 1st station from the D side.
• Under the manifold part number, state the valves to be mounted in order from
the 1st station as shown in the figure above. If the arrangement becomes
complicated, specify on a manifold specification sheet.
Note) When mixing top ported configurations, select from page 202.
In this case, use caution as there is also output on the A and B port on base
Manifold Options

side.
Specify on a manifold specification sheet if plugs are required on the A and B
port on base side.
Protective class
class III (Mark: )

194
Series SY5000/7000

How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 7 1 0 0 5 1
          
Base mounted

 Series  Pilot valve option  Manual override


5 SY5000 Nil Standard (102 psi (0.7 MPa)) Nil: D:
7 SY7000 B Quick response type (102 psi (0.7 MPa)) Non-locking Push-turn
K∗ High pressure type (145 psi (1.0 MPa)) push type locking
∗ Only metal seal type is available for the high slotted
pressure type. type
 Type of actuation
1 Single
2
2-position
Double  Coil type
E: F:
3 Closed center Nil Standard Push-turn Slide locking
4 3-position Exhaust center T With power saving circuit (Continuous duty type) locking type
5 Pressure center ∗ Be sure to select the power saving circuit type lever
A∗ N.C./N.C. when the valve is continuously energized for type
4-position
B∗ dual 3-port
N.O./N.O. long periods of time.
C∗ N.C./N.O. ∗ Be careful of the energizing time when the
power saving circuit is selected. Refer to page
∗ Only rubber seal type is available for the 244 for details. ∗ Refer to page 14 for with the safety slide locking
4-position dual 3-port valve. manual override.

 Rated voltage
 Seal type 5 24 VDC  Type of mounting screw
0 Rubber seal 6 12 VDC Nil Round head combination screw
1 Metal seal ∗ Only 24 VDC is available for the serial B Hexagon socket head cap screw
transmission type. Round head combination screw
K (Falling-out-prevention type)
Hexagon socket head cap screw
 Pilot type  Light/surge voltage suppressor H (Falling-out-prevention type)
Nil Internal pilot and common specification
∗ For “K” and “H”, the valve body cover has a drop
R External pilot Symbol With light
Surge voltage Common prevention construction to stop the mounting
suppressor specification screws from falling out when the valve is
Nil — — removed for maintenance etc.
R — Non-polar ∗ When ordering a valve individually, the base
 Back pressure check valve U  gasket is not included. Since the base gasket is
(Built-in valve type) attached to the manifold, please order the base
S —

Positive gasket separately if it is needed for maintenance
Nil None Z  common service.
H Built-in NS — Negative Refer to page 220 for part numbers of the base
∗ Only rubber seal type. Manifold installed type is NZ  common gasket and mounting screw.
available if back pressure check valve is ∗ “Nil” is not available for the SI unit manifold. ∗ “B” and “H” cannot be selected for the individual
required for the valve with metal seal. Refer to ∗ Only “Z” and “NZ” types are available for with SUP/EXH spacer assembly, interface regulator
page 232 for Ordering Example. However, it is the power saving circuit. Select a valve which is or double check spacer assembly with residual
not recommended to use the built-in valve type suited to the SI unit output polarity or SI unit pressure release valve.
and the manifold installed type at the same time specification when the SI unit is selected.
because it will reduce the flow. Refer to the pages below for details.
∗ The built-in valve type back pressure check EX500: P. 131 EX600: P. 139 EX250: P. 151
valve is not available for the 3-position type and EX260: P. 159 EX126: P. 167 EX120: P. 175
the SY7000.

Protective class
class III (Mark: )
195
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 10/Side Ported

Dimensions: Series SY3000/5000 Connector Connecting Base Mixed Mounting Type

U
SS5Y5-M10- Stations D D side
(L5) L1
U side
Manual override

Sub-plate
B

DIN rail holding screw (


Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail Light/surge voltage suppressor : Gray (For metal seal)

Plug-in
2(B) port side : Yellow

5.5
LOCK

B A B A B A B A B A

35
14 A 14 A 14 A 14 A 14 A

97.5

113.4
FREE

81.2

Metal Base
12 B 12 B
(61.7)

61.7
5.5
12 B 12 B
10.9

4 x M5

Plug-in
4.7
(5.9)
(8.3)
mounting hole
21.9 L2 1.5 (Fitting for the type with P
and E ports on both sides)
5.3 (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

Manifold Exploded View


One-touch fitting

Type 50, 51, 52


(Station 1) --------- (Station n) [4(A), 2(B) port]
One-touch fitting
Applicable tube O.D.: ø2
[4(A), 2(B) port] Compatible with mixed : ø3.2, ø1/8"
Applicable tube O.D.: ø4, ø5/32" mounting type: ø8, ø5/16" : ø4, ø5/32"
: ø6, ø1/4" SY3000 : ø6, ø1/4"

(Slide locking manual override)


: ø8, ø5/16"

(SY3000)

(SY3000)
11.1

31.5

78.9
1 P 1 P

Connector Connecting Base


73.2
2 B2 B2 B2 B2 B

3/5 E 4 A4 A4 A 3/5 E 8.7


33.4

4 A4 A
12.4

14.1
(SY5000 and SY3000: ø8, ø5/16")
29.1
(SY5000 and SY3000: ø8, ø5/16")
(11.8)
One-touch fitting 35.9 18 (20.5) (For DIN rail mounting)
(7.5)

[1(P), 3/5(E) port]


Applicable tube O.D.: ø10, ø3/8" (
Pitch of
SY5000 ) (
Pitch of
SY3000 )
P = 16

Plug-in
P = 12.5
Calculation formula for dimensions with
D-sub connector <IP40>, Flat ribbon cable and PC wiring
L1 = 12.5 x n1 + 16 x n2 + 76.4
L2 = 12.5 x n1 + 16 x n2 + 48
( Pitch of SY3000: ø8,
ø5/16"
P = 16
) One-touch fitting
[4(A), 2(B)port]

Manifold Exploded View


Applicable tube O.D.: ø8, ø5/16"
M = (L1 + 6.1)/12.5 + 1 Decimal fractions are truncated.

Type 10, 11, 12


L3 = 12.5 x M + 23
L4 = L3 – 10.5
L5 = (L3 – L1 + 6.1)/2
Note) Refer to pages 181 and 182 for
n1: Number of valve stations of the SY3000
n2: Number of valve stations of the SY5000 dimensions of external pilot,
(Including the stations of the SY3000: ø8, ø5/16") built-in silencer and elbow fittings.

Calculation formula for dimensions with


D-sub connector <IP67>, Terminal block box, Lead wire,
Circular connector, EX500/600/250/260/126/120
Plug Assembly Part No.

serial transmission
One-touch Fittings/

Coefficient a b c
L1 = 12.5 x n1 + 16 x n2 + a + b x n3
L2 = 12.5 x n1 + 16 x n2 x 48 D-sub connector <IP67> 90.5 — —
M = L1/12.5 + 1 Decimal fractions are truncated. Terminal block box or Serial transmission: EX126 149.3 — —
L3 = 12.5 x M + 23
L4 = L3 – 10.5 Lead wire or Circular connector 97 — —
L5 = (L3 – L1)/2 Serial transmission: EX500 88.5 — —
L6 = b x n3 + c
Manifold Options

Serial transmission: EX600 (M12 connector) 141.5 47 81.5


n1: Number of valve stations of the SY3000
n2: Number of valve stations of the SY5000 Serial transmission: EX600 (7/8 inch connector) 158 47 81.5
(Including the stations of the SY3000: ø8, ø5/16") Serial transmission: EX250 141.5 21 81.5
n3: Number of I/O units or input block stations
Serial transmission: EX260 88.7 — —
Note) Refer to pages 142 to 143 for dimensions of the EX600 serial Serial transmission: EX120 84.7 — —
transmission with I/O unit and page 153 for the EX250 serial
transmission with input block when L6, b and
c are used for the calculation formula. 196
Series SY3000/5000/7000

Plug-in Type 10/Side Ported

Dimensions: Series SY5000/7000 Connector Connecting Base Mixed Mounting Type

U
SS5Y7-M10- Stations D
B D side U side Manual override

(L5) L1 ( Push-turn locking slotted type:


Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
DIN rail holding screw : Gray (For metal seal)
(For DIN rail mounting) 2(B) port side : Yellow
Light/surge voltage suppressor (8)

(DIN rail)
LOCK

B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A

128.8
115

SY5000: 95.7
SY7000: 96.7
FREE

(5.5)
(35)
(77.1)

12 B 12 B 12 B

12 B 12 B

5.5
8.8

3.9
(6)
(9.3)

(A, B port: ø12)


(17.9)

4 x M5 mounting hole

(Fitting for the type with P/E


20.7 L2 1.5 ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)
One-touch fitting (For SY5000)
[4(A), 2(B) port]
Applicable tube O.D.: ø6 ,ø1/4"
(Station 1) (Station n)
: ø8 ,ø5/16"
: ø10,ø3/8"
: ø12
manual override)
(Slide locking
85.8
82.7

1 P 1 P
2 B2 B2 B2 B2 B

3/5
11.1

3/5 E E
8.7
35.2

31.6

4 A4 A4 A4 A4 A
14.2

(10)

(For DIN rail

(21.7)
mounting)
(14.3)

One-touch fitting 39.5 20.5


[1(P), 3/5(E) port]
Applicable tube O.D.: ø12, ø1/2" (Pitch) (Pitch)
P = 19 P = 19

One-touch fitting (For SY7000)


[4(A),2(B) port]
Applicable tube O.D.: ø6 ,ø1/4"
: ø8 ,ø5/16"
: ø10,ø3/8"
: ø12
Note 1) Refer to page 183 for dimensions of external pilots and built-in silencers.
Note 2) Refer to the below pages for L1, L2, L3, L4 dimensions and other dimensions that are not specified in each wiring specification.
D-sub connector <IP40> : P. 86
D-sub connector <IP67> : P. 89
Flat ribbon cable : P. 92
Terminal block box : P. 104
Lead wire : P. 114
Circular connector : P. 124
EX500 : P. 134
EX600 : P. 144, 145
EX250 : P. 154
EX260 : P. 162
EX126 : P. 170
197 EX120 : P. 178
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 11/Bottom Ported

Dimensions: Series SY3000/5000 Connector Connecting Base Mixed Mounting Type

U L1 U side
SS5Y5-M11- Stations D D side

Sub-plate
B Manual override

(Push-turn locking slotted type:


Press, then rotate it. )
4(A) port side : Blue (For rubber seal) 4 x M5 mounting hole
: Gray (For metal seal)

Plug-in
2(B) port side : Yellow

LOCK
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A

97.5
113.4
FREE

81.2
12 B 12 B

Metal Base
5.5
12 B 12 B

10.9
21.9 L2 1.5

Plug-in
(Station 1) --------- (Station n)
Compatible with mixed
mounting type: ø8, ø5/16"
Panel fitting dimensions
SY3000

manual override)

Manifold Exploded View


(Slide locking
7

Type 50, 51, 52


78.9
73.2
60

97.5

4.7

(SY3000)
(12.9)

(SY5000)

(Fitting for the type with P

(7.3)
(9.5)

and E ports on both sides)

Connector Connecting Base


L2 4 x M5 mounting hole (Pitch of SY3000: ø8, ø5/16")
4 x ø5.5 P=16
(Pitch of SY5000) (Pitch of SY3000)
P=16 P=12.5
4.7

35.9 18 (20.5)

Calculation formula for dimensions )


SY5000 and

ø8, ø5/16"
31.8

SY3000:

(SY3000)
L1 = 12.5 x n1 + 16 x n2 + a + b x n3
39.7

3/5 E 3/5 E 49.6


L2 = 12.5 x n1 + 16 x n2 + 48

Plug-in
2 B2 B2 B
L6 = b x n3 + c
) (
18

2 B2 B
Fitting dimensions for panel mounting
n1: Number of valve stations of the SY3000
(

Refer to panel fitting dimensions 1 P


4 A4 A4 A
1 P
n2: Number of valve stations of the SY5000
(SY3000)

Manifold Exploded View


for details. 4 A4 A
SY5000 and

ø8, ø5/16"

(Including the stations of the SY3000: ø8, ø5/16")


SY3000:

11

Type 10, 11, 12


n3: Number of I/O units or input block stations
15

Note) Refer to pages 142 and 143 for dimen- One-touch fitting
sions of the EX600 serial transmission
(

[1(P), 3/5(E) port]


with I/O unit and page 153 for the EX250 Applicable tube O.D.: ø10, ø3/8" One-touch fitting
serial transmission with input block when One-touch fitting [4(A), 2(B) port]
L6, b and c are used for the calculation Applicable tube O.D.: ø2
[4(A), 2(B) port]
formula. Applicable tube O.D.: ø4, ø5/32" : ø3.2, ø1/8"
: ø6, ø1/4" : ø4, ø5/32"
: ø8, ø5/16" One-touch fitting : ø6, ø1/4"
Plug Assembly Part No.
One-touch Fittings/

Coefficient a b c [4(A), 2(B) port]


Applicable tube O.D.: ø8, ø5/16"
D-sub connector <IP40>, Flat ribbon cable or PC wiring 76.4 — —
D-sub connector <IP67> 90.5 — —
Terminal block box or Serial transmission: EX126 149.3 — —
Lead wire or Circular connector 97 — —
Serial transmission: EX500 88.5 — — Note) Refer to page 184 for dimensions of external pilots
Manifold Options

Serial transmission: EX600 (M12 connector) 141.5 47 81.5 and built-in silencers.
Serial transmission: EX600 (7/8 inch connector) 158 47 81.5
Serial transmission: EX250 141.5 21 81.5
Serial transmission: EX260 88.7 — —
Serial transmission: EX120 84.7 — —

198
Series SY3000/5000/7000

Plug-in Type 11/Bottom Ported

Dimensions: Series SY5000/7000 Connector Connecting Base Mixed Mounting Type

U
SS5Y7-M11- Stations D D side
L1
U side
B
Manual override

(Push-turn locking slotted type:


Press, then rotate it. )
4(A) port side: Blue (For rubber seal) (Light/surge voltage suppressor)
: Gray (For metal seal)
2(B) port side: Yellow

LOCK
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A

128.8
115

SY5000: 95.7
SY7000: 96.7
FREE

12 B 12 B 12 B

12 B 12 B

5.5
8.8

20.7 L2 1.5 4 x M5 mounting hole

(Station 1) (Station n)

(Slide locking manual override)


Panel fitting dimensions

2
16

85.8
82.7
56.6
9.1
60

115

(12)
(14.5)
(23.9)

(Fitting for the type with P/E


(A, B port: ø12) ports on the U and/or D sides)

L2 4 x M5 mounting hole (Pitch) (Pitch)


4 x ø5.5 39.5 20.5 P = 19 P = 19 (21.7)
3.9
39.9

48.7

3/5 E 3/5 E

2 B2 B2 B2 B2 B
21

19.5

4 A4 A4 A4 A4 A

1 P 1 P

Fitting dimensions for panel


One-touch fitting mounting
[1(P), 3/5(E) port] Refer to panel fitting
Applicable tube O.D.: ø12,ø1/2" dimensions for details.

Note 1) Refer to page 185 for dimensions of external pilots and built-in silencers.
Note 2) Refer to the below pages for L1, L2 dimensions and other dimensions One-touch fitting (For SY7000) One-touch fitting (For SY5000)
that are not specified in each wiring specification. [4(A), 2(B) port] [4(A), 2(B) port]
Dimensions of Type 11/Bottom ported : P. 185 Applicable tube O.D.: ø6 ,ø1/4" Applicable tube O.D.: ø6 ,ø1/4"
: ø8 ,ø5/16" : ø8 ,ø5/16"
D-sub connector <IP40> : P. 86
: ø10,ø3/8" : ø10,ø3/8"
D-sub connector <IP67> : P. 89 : ø12 : ø12
Flat ribbon cable : P. 92
Terminal block box : P. 104
Lead wire : P. 114
Circular connector : P. 124
EX500 : P. 134
EX600 : P. 144, 145
EX250 : P. 154
EX260 : P. 162
EX126 : P. 170
199 EX120 : P. 178
200
One-touch Fittings/ Type 10, 11, 12 Type 50, 51, 52
Manifold Options Plug-in Connector Connecting Base Plug-in Metal Base Plug-in Sub-plate Valve
Plug Assembly Part No. Manifold Exploded View Manifold Exploded View
Plug-in Connector Connecting Base: Plug-in Mixed Mounting Type Manifold
D-sub Connector (IP40/67) Flat Ribbon Cable PC Wiring Terminal Block Box (IP67) Lead Wire (IP67)
Circular Connector (IP67) EX500 (IP67) EX600 (IP67) EX250 (IP67) EX260 (IP67) EX126 (IP67) EX120

Series SY3000/5000/7000
Type 12
Top Ported
For the SY5000 series, the SY5000 and the SY3000
can be mounted on the same manifold.
For the SY7000 series, the SY7000 and the SY5000
can be mounted on the same manifold. How to Order Manifold
Refer to pages 187 and 188
for dimensions of Type
12/Top ported type.
SS5Y 5 M 12 F 1 05 U
       
Mixed Mounting Type
For the SY5000 series, it is possible to mount the SY3000 size valves on all
stations. However, the SY3000 manifold block width should be 12.5 mm.
(16 mm for ø8 or ø5/16" One-touch fitting)
Also, for the SY7000 series, it is possible to mount the SY5000 size valves on
all stations. However, the SY3000 cannot be mounted onto the SY7000 series.

 Series  Connector type  Valve stations


5 SY5000 Symbol Type Page Symbol Stations Note
7 SY7000 F D-sub connector IP40 02 2 stations Some connectors have a limitation
FW (25 pins) IP67 on the number of stations. Refer


···

···
to the pages shown in the table
P 26 pins 24 24 stations “Connector type” for details.
• With Lead wire PG Flat ribbon cable 20 pins 93
PH 10 pins
Lead wire length J PC wiring —
1 0.6 m G (20 pins) With power supply terminal
 P, E port entry
2 1.5 m T Terminal block box 105 U Note) U side (2 to 10 stations)
3 3m L1 34 cores D Note) D side (2 to 10 stations)
L2 Lead wire 17 cores 115 B Both sides (2 to 24 stations)
• With D-sub connector (IP40/67), Flat L3 9 cores ∗ Refer to page 147 for the EX600 and  on page
ribbon cable and PC wiring M Circular connector 125 155 for the EX250.
Connector entry direction S EX500 135 Note) For type “S”, supply/exhaust block assembly
with built-in silencer, choose U or D for P
1 Upward S6 EX600 147
port entry.
2 Lateral S Serial EX250 155
S transmission EX260 163
∗ It is not necessary to select the items above for S4 EX126 171  SUP/EXH block assembly
the valve with terminal block box or with circular
S3 EX120 179 Nil Internal pilot
connector or the serial transmission type.
∗ Refer to the pages shown in the table above for details. S Internal pilot, Built-in silencer
How to Order Manifold Assembly R External pilot
∗ For built-in silencer type, P and E ports are
available on U and D sides. 3/5(E) port is
Example (SS5Y5-M12F1-) plugged. The silencer exhaust port is located on
the opposite side of P, E port entry. (Example:
2-position double 2-position double
When the P, E port entry is D side, the silencer
SY5230-5U1-C8 (3 sets) SY3230-5U1-C6 (2 sets) exhaust port is U side.)
∗ Refer to page 147 for the EX600 and  on page
Manifold base (5 stations) 155 for the EX250.
SS5Y5-M12F1-05D

 P, E port size
(One-touch fittings)
e
Symbol SY5000 SY7000 Note
U sid Nil ø10 ø12 Metric size
s
ati
on N ø3/8" ø1/2" Inch size
St
3
2
ide
1
 Mounting
Ds
Nil Direct mounting
SS5Y5-M12F1-05D ···1 set (Type M12 5-station manifold base part no.) D DIN rail mounting (With DIN rail)
∗SY5230-5U1-C8 ········3 sets (2-position double part no.) D0 DIN rail mounting (Without DIN rail)
∗SY3230-5U1-C6 ········2 sets (2-position double part no.) D3 For 3 stations Specify a longer rail than the standard
length. [For the SS5Y5-M12, the SY5000
The asterisk denotes the symbol for assembly.
···

···

valve is now at a mountable length


Prefix it to the part numbers of the valve etc. D24 For 24 stations (manifold block length of 16 mm).]
• The valve arrangement is numbered as the 1st station from the D side. Note 1) Refer to page 203 to determine the L3 using “Calculation
• Under the manifold part number, state the valves to be mounted in order formula” for the DIN rail length. (For the SY3000 and
from the 1st station as shown in the figure above. If the arrangement SY5000 mixed mounting type)
becomes complicated, specify on a manifold specification sheet. Note 2) Refer to page 247 for the fixation of DIN rail mounting type
manifold.
201
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
How to Order Valves (With mounting screw) Refer to page 3 for valve specifications.

SY 3 1 3 0 5 1 C6

Sub-plate
            

Plug-in
Top ported

 Series  Coil type  A, B port size


3 SY3000 Nil Standard Thread piping
5 SY5000 T With power saving circuit (Continuous duty type) Symbol Port size Applicable series
7 SY7000 ∗ Be sure to select the power saving circuit type M5 M5 x 0.8 SY3000
when a valve is continuously energized for long 01 1/8 SY5000

Metal Base
periods of time. 02 1/4 SY7000
∗ Be careful of the energizing time when the
 Type of actuation power saving circuit is selected. Refer to page One-touch fitting (Metric)
1 Single 244 for details. Symbol A, B port SY3000 SY5000 SY7000
2-position
2 Double C2 ø2  — —
3

Plug-in
Closed center  Rated voltage C3 ø3.2  — —
4 3-position Exhaust center C4 ø4   —
5 24 VDC
5 Pressure center C6 ø6   
6 12 VDC
A∗ N.C./N.C. C8 ø8 —  
4-position ∗ Only 24 VDC is available for the serial
B∗ dual 3-port
N.O./N.O. C10 ø10 — — 
transmission type.
C∗ N.C./N.O. C12

Manifold Exploded View


ø12 — — 
∗ Only rubber seal type is available for the

Type 50, 51, 52


4-position dual 3-port valve.  Light/surge voltage suppressor One-touch fitting (Inch)
and common specification Symbol A, B port SY3000 SY5000 SY7000
Surge voltage Common N1 ø1/8"  — —
Symbol With light N3 ø5/32"   —
 Seal type suppressor specification
N7 ø1/4"   
Nil — —
0 Rubber seal N9 ø5/16" —  
R — Non-polar
1 Metal seal N11 ø3/8" — — 
U 

Connector Connecting Base


S — Positive

Z  common
 Pilot type NS — Negative  Thread type
Nil Internal pilot NZ  common Nil Rc
R External pilot ∗ “Nil” is not available for the SI unit manifold. F G
∗ Only “Z” and “NZ” types are available for with N NPT
the power saving circuit. Select a valve which is T NPTF
suited to the SI unit output polarity or SI unit
 Back pressure check valve specification when the SI unit is selected. ∗ Only Nil is available for M5.
(Built-in valve type) Refer to the pages below for details.

Plug-in
Nil None EX500: P. 136 EX600: P. 148 EX250: P. 156
H Built-in EX260: P. 164 EX126: P. 172 EX120: P. 180  Type of mounting screw
∗ Only rubber seal type. Manifold installed type is Nil Round head combination screw

Manifold Exploded View


available if the back pressure check valve is
B Hexagon socket head cap screw

Type 10, 11, 12


required for a valve with metal seal. Refer to
Round head combination screw
page 232 for Ordering Example. However, it is  Manual override K (Falling-out-prevention type)
not recommended to use the built-in valve type
and the manifold installed type at the same time Nil: D: Hexagon socket head cap screw
H (Falling-out-prevention type)
because it will reduce the flow. Non-locking Push-turn
∗ The built-in valve type back pressure check push type locking ∗ For “K” and “H”, the valve body cover has a
valve is not available for the 3-position type and slotted drop prevention construction to stop the
the SY7000. type mounting screws from falling out when the
valve is removed for maintenance etc.
 Pilot valve option ∗ When ordering a valve individually, the base
Plug Assembly Part No.
One-touch Fittings/

gasket is not included. Since the base gasket is


Nil Standard (102 psi (0.7 MPa)) attached to the manifold, please order the base
B Quick response type (102 psi (0.7 MPa)) E: F: gasket separately if it is needed for
K∗ High pressure type (145 psi (1.0 MPa)) Push-turn Slide locking maintenance service.
locking type Refer to page 220 for part numbers of the base
∗ Only metal seal type is available for the high lever
pressure type. gasket and mounting screw.
type ∗ “B” and “H” cannot be selected for the individual
Manifold Options

SUP/EXH spacer assembly or interface


regulator.

∗ Refer to page 14 for with the safety slide locking


manual override. Protective class
class III (Mark: )

202
Series SY3000/5000/7000

Plug-in Type 12/Top Ported

Dimensions: Series SY5000 Connector Connecting Base Mixed Mounting Type

U
SS5Y5-M12- Stations D D side U side
B
(L5) L1

( Pitch of
SY5000 ) Manual override
Light/surge voltage suppressor
32.8 21.1 P = 16
(
Push-turn locking slotted type:
Press, then rotate it. )
78.9
(Slide locking manual override)
(
Pitch of
SY3000 ) 4(A) port side : Blue (For rubber seal)
: Gray (For metal seal)
P = 12.5
2(B) port side : Yellow

(8)
PE
LOCK

3/5 B A B A B A B A B A

(5.5)

(35)
4A 4A
4A 4A 4A

113.4
E
26.5
FREE

X
1

(SY3000)

81.2
(SY3000)
2B 2B
(61.7)

(SY5000)
11
01 : 16.2
C: 14.5
(SY5000)

56.4
P

47.3
39.5

2B 2B 2B

2.7
4.7

One-touch fitting
[1(P), 3/5(E) port] One-touch fitting One-touch fitting
Applicable tube O.D.: ø10, ø3/8" [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: ø4, ø5/32" Applicable tube O.D.: ø2
: ø6, ø1/4" : ø3.2, ø1/8"
: ø8, ø5/16" : ø4, ø5/32"
5.3 L4 : ø6, ø1/4"
(DIN rail mounting hole pitch: 12.5)
L3

(Station 1) --------- (Station n)

Calculation formula for dimensions with


(SY5000)

(SY3000)
(91.3)

D-sub connector <IP40>, Flat ribbon cable (87.4)


1 P 1 P
(69.7)

and PC wiring 2 B2 B2 B2 B2 B

L1 = 12.5 x n1 + 16 x n2 + 76.4 3/5 E 4 A4 A4 A 3/5 E


4 A4 A
L2 = 12.5 x n1 + 16 x n2 + 48
M = (L1 + 6.1)/12.5 + 1 Decimal fractions are truncated.
L3 = 12.5 x M + 23
L4 = L3 – 10.5
(For DIN rail
(7.5)

mounting)
(11.8)

L5 = (L3 – L1 + 6.1)/2
n1: Number of valve stations of the SY3000
n2: Number of valve stations of the SY5000

Calculation formula for dimensions with D-sub Note) Refer to page 182 for dimensions of
connector <IP67>, Terminal block box, Lead wire, external pilot and elbow fittings.
Circular connector, EX500/600/250/260/126/120
serial transmission
L1 = 12.5 x n1 + 16 x n2 + a + b x n3
L2 = 12.5 x n1 + 16 x n2 x 48
M = L1/12.5 + 1 Decimal fractions are truncated.
L3 = 12.5 x M + 23 Coefficient a b c
L4 = L3 – 10.5 D-sub connector <IP67> 90.5 — —
L5 = (L3 – L1)/2 Terminal block box or Serial transmission: EX126 149.3 — —
L6 = b x n3 + c Lead wire or Circular connector 97 — —
n1: Number of valve stations of the SY3000 Serial transmission: EX500 88.5 — —
n2: Number of valve stations of the SY5000 Serial transmission: EX600 (M12 connector) 141.5 47 81.5
n3: Number of I/O units or input block stations
Serial transmission: EX600 (7/8 inch connector) 158 47 81.5
Note) Refer to pages 142 and 143 for dimensions of the
Serial transmission: EX250 141.5 21 81.5
EX600 serial transmission with I/O unit and page 153
for the EX250 serial transmission with input block Serial transmission: EX260 88.7 — —
when L6, b and c are used for the calculation formula. Serial transmission: EX120 84.7 — —

203
Plug-in Connector Connecting Base Series SY3000/5000/7000

Valve
Plug-in Type 12/Top Ported

Dimensions: Series SY7000 Connector Connecting Base Mixed Mounting Type

U
SS5Y7-M12- Stations D

Sub-plate
B
D side U side
L1

(Light/surge voltage suppressor)

Plug-in
Manual override
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: ø12, ø1/2"
33.9
(Pitch)
26.1 P = 19
(Pitch)
P = 19 42.2 (
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
85.8 : Gray (For metal seal)
(Slide locking manual override) 2(B) port side: Yellow

Metal Base
PE
LOCK

3/5E B A B A B A B A B A
4A 4A 4A 4A 4A
21

128.8
FREE

SY5000: 95.7
SY7000: 96.7

Plug-in
(SY5000)
C: 14.5
01: 16.2
1P

(SY5000)
77.1

(SY7000)

(SY7000)

X 2B 2B 2B
22.6

61.8
59.9

57.7

2B 2B

Manifold Exploded View


Type 50, 51, 52
1/8
2.4
3.9

4 x M5 mounting hole
1/4 [A(A), 2(B) port]
[A(A), 2(B) port]
20.7 L2 1.5
(DIN rail mounting hole pitch: 12.5) One-touch fitting (For SY5000)
One-touch fitting (For SY7000) [4(A), 2(B) port]
[4(A), 2(B) port] Applicable tube O.D.: ø4, ø5/32"
Applicable tube O.D.: ø6 , ø1/4" : ø6, ø1/4"
: ø8 , ø5/16" (Station 1) (Station n) : ø8, ø5/16"
: ø10, ø 3/8"

Connector Connecting Base


: ø12
(A, B port: ø12)
(SY7000)
(112.1)

(SY7000)

(SY5000)
(100.3)

(SY7000)

(98.2)
(SY5000)

Plug-in
88.8

83.8

1 P 1 P
(75.1)

2 B2 B2 B2 B2 B

3/5 E 3/5 E
4 A4 A4 A4 A4 A

Manifold Exploded View


Type 10, 11, 12

Note 1) Refer to page 183 for dimensions of external pilot and elbow fittings.
Plug Assembly Part No.

Note 2) Refer to the below pages for L1, L2, L3, L4 dimensions and other
One-touch Fittings/

dimensions that are not specified in each wiring specification.


Dimensions of Type 12/Top ported : P. 188
D-sub connector <IP40> : P. 86
D-sub connector <IP67> : P. 89
Flat ribbon cable : P. 92
Terminal block box : P. 104
Lead wire : P. 114
Manifold Options

Circular connector : P. 124


EX500 : P. 134
EX600 : P. 144, 145
EX250 : P. 154
EX260 : P. 162
EX126 : P. 170
EX120 : P. 178
204
205
Series SY3000/5000/7000 Type 10, 11, 12

Valve
Connector Connecting Base Manifold Exploded View
Manifold Exploded View Page 219 U side

Sub-plate
Plug-in
D side

Metal Base
Plug-in
LOC
K
FRE
E

Manifold Exploded View


Type 50, 51, 52
∗ The figures show the SY3000 series.

Connector Connecting Base


D-sub connector <IP40> D-sub connector <IP67> Terminal block box
/Flat ribbon cable Page 208 Page 209
Page 207

Wiring

Plug-in
Manifold Exploded View
Type 10, 11, 12
Lead wire Circular connector EX500 EX600
Page 210 Page 211 Page 212 Page 213

Plug Assembly Part No.


One-touch Fittings/

EX250 EX260 EX126 EX120


Page 215 Page 216 Page 217 Page 218
Manifold Options

206
Series SY3000/5000/7000
Wiring
D-sub Connector <IP40>/Flat Ribbon Cable Manifold exploded view

q
U side
Locking bracket
(For D-sub connector)
LOC
Cover assembly K

Silencer cover assembly FRE


E
Port block assembly a
Refer to page 223. Tension
bolt

Holding screw
D side
w Clamp bracket assembly
It is mounted only for the DIN rail mounting type. Refer to pages 219 to 222
The holding screw of the clamping bracket is for details about common parts.
tightened at one point.
(Tightening torque of holding screw: 10.3 lbf·ft (1.4 N·m))

Manifold Parts No.


qSUP/EXH block assembly
Mounting
SY 3 0M 1 11 A 1 C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series
∗ For bottom ported, the symbol is nil.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Connector entry direction
1 Upward C8 ø8  — — Side/Bottom/
SUP/EXH block assembly 2 Lateral C10 ø10 —  — Top ported
11 D-sub connector <IP40> C12 ø12 — —  Metric size
12 Flat ribbon cable (26 pins) N9 ø5/16"  — — Side/Bottom/
13 Flat ribbon cable (20 pins) Pilot, Silencer/Piping type N11 ø3/8" —  — Top ported
14 Flat ribbon cable (10 pins) Pilot type Built-in Piping N13 ø1/2" — —  Inch size
Symbol Internal External silencer direction
L8 ø8  — —
Downward elbow Upward elbow

Side ported
Nil  — — L10 ø10 —  — Metric size
S  —  Side L12 ø12 — — 
R —  — LN9 ø5/16"  — —
Side ported
V  — — LN11 ø3/8" —  — Inch size
RV —  — Top LN13 ø1/2" — — 
VP  — ∗ B8 ø8  — —
Side ported
B  — — B10 ø10 —  — Metric size
BS  —  Bottom B12 ø12 — — 
BR —  — BN9 ø5/16"  — —
Side ported
∗ For silencer (supply side). E port is BN11 ø3/8" —  — Inch size
plugged. BN13 ø1/2" — — 
Note) “B” for bottom ported can be 00 Note 1) Plug    P/E port entry on one
selected for the SY5000/7000 00U Note 2) Plug    side or Top ported
series. Note 1) It can be selected only if no symbol or “S” or “V” or “B” is
SUP/EXH block assembly (D side) selected for the pilot and the piping.
accessories and the number of accessories Note 2) “00U” is available only for the D-sub connector type and it has
an inch size locking bracket.
Accessories SY3000 SY5000
SY7000
a Tension bolt None Note) 3 pcs.
Note) Since the nuts are embedded in the SUP/EXH block.

wClamp bracket assembly


Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A
∗ Part number is for one assembly.

207
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View Series SY3000/5000/7000

Valve
Wiring
D-sub Connector <IP67> Manifold exploded view

q
U side

Sub-plate
w

Plug-in
Locking a
bracket Tension
bolt

Mounting screw
(Tightening torque:

Metal Base
0.59 lbf·ft (0.8 N·m))
D side
Holding screw
Refer to pages 219 to 222
e Clamp bracket assembly for details about common parts.

Plug-in
It is mounted only for the DIN rail mounting type.
The holding screws of the clamping bracket is
tightened at two points.
(Tightening torque of holding screw: 10.3 lbf·ft (1.4 N·m))

Manifold Exploded View


Manifold Parts No.

Type 50, 51, 52


q SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series
∗ For bottom ported, the symbol is nil.
3 SY3000
5

Connector Connecting Base


SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
C8 ø8  — — Side/Bottom/
C10 ø10 —  — Top ported
C12 ø12 — —  Metric size
N9 ø5/16"  — — Side/Bottom/
Pilot, Silencer/Piping type N11 ø3/8" —  — Top ported
Pilot type Built-in Piping N13 ø1/2" — —  Inch size
Symbol Internal External silencer direction
L8 ø8  — —
Downward elbow Upward elbow

Nil — — Side ported


 L10 ø10 —  — Metric size
S — Side L12 ø12

Plug-in
  — — 
R —  — LN9 ø5/16"  — —
V — — Side ported
 LN11 ø3/8" —  — Inch size
RV —  — Top LN13 ø1/2" — — 
∗

Manifold Exploded View


VP  — B8 ø8  — —
Side ported

Type 10, 11, 12


B  — — B10 ø10 —  — Metric size
BS  —  Bottom B12 ø12 — — 
BR —  — BN9 ø5/16"  — —
Side ported
∗ For silencer (supply side). E port is BN11 ø3/8" —  — Inch size
plugged. BN13 ø1/2" — — 
Note) “B” for bottom ported can be 00 Note 1) Plug    P/E port entry on one
selected for the SY5000/7000 00U Note 2) Plug    side or Top ported
series. Note 1) It can be selected only if no symbol or “S” or “V” or “B” is
SUP/EXH block assembly (D side) selected for the pilot and the piping.
Note 2) “00U” has an inch size locking bracket.
Plug Assembly Part No.

accessories and the number of accessories


One-touch Fittings/

Accessories SY3000 SY5000


SY7000
aTension bolt None Note) 3 pcs.
Note) Since the nuts are embedded in the SUP/EXH block.
Manifold Options

w D-sub connector block assembly <IP67> e Clamp bracket assembly


Part no. Connector direction Locking bracket Series Part no.
SY30M-14-9A1 Top SY3000 SY30M-15-1A
Metric size
SY30M-14-9A2 Side SY5000/7000 SY50M-15-1A
SY30M-14-9A1U Top ∗ Part number is for one assembly.
Inch size
SY30M-14-9A2U Side
208
Series SY3000/5000/7000
Wiring
Terminal Block Box Manifold exploded view
Mounting screw q
(Tightening torque: 0.59 lbf·ft (0.8 N·m))
U side
w

a
Tension
bolt

Mounting screw for


connecting parts Holding D side
(Tightening torque: screw
0.59 lbf·ft (0.8 N·m)) Refer to pages 219 to 222
for details about common parts.
e
r Clamp bracket assembly
It is mounted only for the DIN rail mounting type.
The holding screws of the clamping bracket is tightened at two points.
(Tightening torque of holding screw: 10.3 lbf·ft (1.4 N·m))

Mounting screw
DIN rail holding screw (Tightening torque: 10.3 lbf·ft (1.4 N·m))
(Tightening torque: 10.3 lbf·ft (1.4 N·m))

Manifold Parts No.


q SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series
∗ For bottom ported, the symbol is nil.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type
Pilot type
C8 ø8  — — Side/Bottom/
Built-in Piping
Symbol Internal External silencer direction C10 ø10 —  — Top ported
C12 ø12 — —  Metric size
Nil  — —
N9 ø5/16"  — — Side/Bottom/
S  —  Side N11 ø3/8" —  — Top ported
R —  —
N13 ø1/2" — —  Inch size
V  — —
L8 ø8  — —
Downward elbow Upward elbow

RV —  — Top L10 ø10 —  —


Side ported
VP  — ∗ Metric size
L12 ø12 — — 
B  — —
LN9 ø5/16"  — —
BS  —  Bottom LN11 ø3/8" —  —
Side ported
BR —  — Inch size
LN13 ø1/2" — — 
∗ For silencer (supply side). E port is B8 ø8  — —
plugged. Side ported
B10 ø10 —  — Metric size
Note) “B” for bottom ported can be selected B12 ø12 — — 
for the SY5000/7000 series. BN9 ø5/16"  — —
SUP/EXH block assembly (D side) Side ported
BN11 ø3/8" —  — Inch size
accessories and the number of accessories BN13 ø1/2" — — 
P/E port entry on one
Accessories SY3000 SY5000
SY7000
00 Note) Plug   
side or Top ported
a Tension bolt None Note) 3 pcs. Note) It can be selected only if no symbol or “S” or “V” or “B” is selected
Note) Since the nuts are embedded in the SUP/EXH block. for the pilot and the piping.

w Terminal block box housing assembly


VVQC1000 T0 1 r Clamp bracket assembly
e Clamp bracket assembly for terminal block box Series Part no.

SY30M 15 4A SY3000
SY5000/7000
SY30M-15-1A
SY50M-15-1A
∗ Part number is for one assembly.
∗ Part number is for one assembly.

209
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View Series SY3000/5000/7000

Valve
Wiring
Lead Wire Manifold exploded view

q
U side

Sub-plate
w

Plug-in
a
Tension
bolt

Mounting screw

Metal Base
(Tightening torque:
0.59 lbf·ft (0.8 N·m)) D side

Refer to pages 219 to 222 for


Holding screw details about common parts.

Plug-in
e Clamp bracket assembly
It is mounted only for the DIN rail mounting type.
The holding screws of the clamping bracket is
tightened at two points.
(Tightening torque of holding screw: 10.3 lbf·ft (1.4 N·m))
Manifold Parts No.

Manifold Exploded View


Type 50, 51, 52
q SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series
∗ For bottom ported, the symbol is nil.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000

Connector Connecting Base


Pilot, Silencer/Piping type Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot type
C8 ø8  — — Side/Bottom/
Built-in Piping
Symbol Internal External silencer direction C10 ø10 —  — Top ported
C12 ø12 — —  Metric size
Nil  — —
N9 ø5/16"  — — Side/Bottom/
S  —  Side N11 ø3/8" —  — Top ported
R —  —
N13 ø1/2" — —  Inch size
V  — —
L8 ø8  — —
Downward elbow Upward elbow

RV —  — Top L10 ø10 —  —


Side ported
VP  — ∗ Metric size
L12 ø12 — — 
B  — —
LN9 ø5/16"  — —

Plug-in
BS  —  Bottom LN11 ø3/8" —  —
Side ported
BR —  — Inch size
LN13 ø1/2" — — 
∗ For silencer (supply side). E port is B8 ø8  — —
plugged. Side ported

Manifold Exploded View


B10 ø10 —  — Metric size
Note) “B” for bottom ported can be B12

Type 10, 11, 12


ø12 — — 
selected for the SY5000/7000 BN9 ø5/16"  — —
series. Side ported
SUP/EXH block assembly (D side) BN11 ø3/8" —  — Inch size
accessories and the number of accessories BN13 ø1/2" — — 
P/E port entry on one
Accessories SY3000 SY5000
SY7000
00 Note) Plug   
side or Top ported
aTension bolt None Note) 3 pcs. Note) It can be selected only if no symbol or “S” or “V” or “B” is
Note) Since the nuts are embedded in the SUP/EXH block. selected for the pilot and the piping.

wLead wire connector block assembly


Plug Assembly Part No.
One-touch Fittings/

SY30M 14 4A
Number of cores Lead wire length (m)
1 34 1 0.6
2 17 2 1.5
Manifold Options

3 9 3 3

eClamp bracket assembly


Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A
∗ Part number is for one assembly. 210
Series SY3000/5000/7000
Wiring
Circular Connector Manifold exploded view

q
U side

a
Tension
bolt

Mounting screw
(Tightening torque:
0.59 lbf·ft (0.8 N·m)) D side

Holding Refer to pages 219 to 222


screw
e Clamp bracket assembly for details about common parts.
It is mounted only for the DIN rail mounting type.
The holding screws of the clamping bracket is
tightened at two points.
(Tightening torque of holding screw: 1.03 lbf·ft (1.4 N·m))

Manifold Parts No.


q SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series
∗ For bottom ported, the symbol is nil.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type
Pilot type
C8 ø8  — — Side/Bottom/
Built-in Piping
Symbol Internal External silencer direction C10 ø10 —  — Top ported
C12 ø12 — —  Metric size
Nil  — —
N9 ø5/16"  — — Side/Bottom/
S  —  Side N11 ø3/8" —  — Top ported
R —  —
N13 ø1/2" — —  Inch size
V  — —
L8 ø8  — —
Downward elbow Upward elbow

RV —  — Top L10 ø10 —  —


Side ported
VP  — ∗ Metric size
L12 ø12 — — 
B  — —
LN9 ø5/16"  — —
BS  —  Bottom LN11 ø3/8" —  —
Side ported
BR —  — Inch size
LN13 ø1/2" — — 
∗ For silencer (supply side). E port is B8 ø8  — —
plugged. Side ported
B10 ø10 —  — Metric size
Note) “B” for bottom ported can be B12 ø12 — — 
selected for the SY5000/7000 BN9 ø5/16"  — —
series. Side ported
BN11 ø3/8" —  — Inch size
SUP/EXH block assembly (D side) BN13 ø1/2" — — 
accessories and the number of accessories P/E port entry on one
00 Note) Plug   
side or Top ported
Accessories SY3000 SY5000
SY7000 Note) It can be selected only if no symbol or “S” or “V” or “B” is selected
a Tension bolt None Note) 3 pcs. for the pilot and the piping.
Note) Since the nuts are embedded in the SUP/EXH block.

w Circular connector block assembly


SY30M 14 5A
∗ 26 pins

e Clamp bracket assembly


Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A
∗ Part number is for one assembly.

211
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View Series SY3000/5000/7000

Valve
Wiring
EX500 Manifold exploded view

Sub-plate
U side

Plug-in
a
Tension
bolt

Mounting screw
(Tightening torque:

Metal Base
0.59 lbf·ft (0.8 N·m))
D side

Holding screw Refer to pages 219 to 222


e Clamp bracket assembly for details about common parts.

Plug-in
It is mounted only for the DIN rail mounting type.
The holding screws of the clamping bracket is
tightened at two points.
(Tightening torque of holding screw: 1.03 lbf·ft (1.4 N·m))

Manifold Parts No.

Manifold Exploded View


Type 50, 51, 52
q SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series
∗ For bottom ported, the symbol is nil.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note

Connector Connecting Base


Pilot, Silencer/Piping type
Pilot type
C8 ø8  — — Side/Bottom/
Built-in Piping
Symbol Internal External silencer direction C10 ø10 —  — Top ported
C12 ø12 — —  Metric size
Nil  — —
N9 ø5/16"  — — Side/Bottom/
S  —  Side N11 ø3/8" —  — Top ported
R —  —
N13 ø1/2" — —  Inch size
V  — —
L8 ø8  — —
Downward elbow Upward elbow

RV —  — Top L10 ø10 —  —


Side ported
VP  — ∗ Metric size
L12 ø12 — — 
B  — —
LN9 ø5/16"  — —
BS

Plug-in
 —  Bottom Side ported
LN11 ø3/8" —  — Inch size
BR —  —
LN13 ø1/2" — — 
∗ For silencer (supply side). E port is B8 ø8  — —
plugged. Side ported
B10 ø10 — —

Manifold Exploded View


 Metric size
Note) “B” for bottom ported can be B12 ø12 — — 

Type 10, 11, 12


selected for the SY5000/7000 BN9 ø5/16"  — —
series. Side ported
SUP/EXH block assembly (D side) BN11 ø3/8" —  — Inch size
accessories and the number of accessories BN13 ø1/2" — — 
P/E port entry on one
00 Note) Plug
SY3000 SY5000
  
side or Top ported
Accessories
SY7000
aTension bolt None Note) 3 pcs. Note) It can be selected only if no symbol or “S” or “V” or “B” is
selected for the pilot and the piping.
Note) Since the nuts are embedded in the SUP/EXH block.
Plug Assembly Part No.

w EX500 SI unit
One-touch Fittings/

EX500 Q 0 01
Output specifications
0 NPN (Positive common)
1 PNP (Negative common)
Manifold Options

∗ Compatible with DeviceNet™, PROFIBUS DP, EtherNet/IP™

eClamp bracket assembly


Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A
∗ Part number is for one assembly. 212
Series SY3000/5000/7000
Wiring
EX600 Manifold exploded view

Mounting screw q
(Tightening torque: 0.59 lbf·ft (0.8 N·m)) U side
w

e
a
Tension
t bolt

D side

Refer to pages 219 to 222


for details about common parts.
u

Holding screw

r Clamp bracket assembly


It is mounted only for the DIN rail mounting type.
The holding screws of the clamping bracket is tightened at two points.
(Tightening torque of holding screw: 1.03 lbf·ft (1.4 N·m))
Manifold Parts No.
qSUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series
∗ For bottom ported, the symbol is nil.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type
Pilot type Built-in Piping C8 ø8  — — Side/Bottom/
Symbol Internal External silencer direction C10 ø10 —  — Top ported
C12 ø12 — —  Metric size
Nil  — —
S  —  Side N9 ø5/16"  — — Side/Bottom/
R —  — N11 ø3/8" —  — Top ported
N13 ø1/2" — —  Inch size
V  — —
RV L8 ø8  — —
Downward elbow Upward elbow

—  — Top Side ported


VP  — ∗ L10 ø10 —  — Metric size
B  — — L12 ø12 — — 
BS  —  Bottom LN9 ø5/16"  — —
Side ported
BR —  — LN11 ø3/8" —  — Inch size
LN13 ø1/2" — — 
∗ For silencer (supply side). E port is plugged. B8 ø8  — —
Note) “B” for bottom ported can be selected for Side ported
B10 ø10 —  — Metric size
the SY5000/7000 series. B12 ø12 — — 
SUP/EXH block assembly (D side) BN9 ø5/16"  — —
accessories and the number of accessories Side ported
BN11 ø3/8" —  — Inch size
BN13 ø1/2" —
SY3000 SY5000
— 
Accessories
SY7000 00 Note) Plug
P/E port entry on one
  
a Tension bolt None Note) 3 pcs. side or Top ported
Note) Since the nuts are embedded in the SUP/EXH block. Note) It can be selected only if no symbol or “S” or “V” or “B” is
selected for the pilot and the piping.

wValve plate e EX600 SI unit


EX600 ZMV2 EX600 S PR 1
∗ With mounting screws
(2 pcs. of M4 x 6 and 2 pcs. of M3 x 8) Protocol Version
Symbol Description Symbol Description
PR PROFIBUS DP Nil When MJ, EN, EC or PN is selected
rClamp bracket assembly DN DeviceNet™ A When PR or DN is selected
MJ CC-Link
Series Part no.
EN EtherNet/IP™ Note) Output type
SY3000 SY30M-15-1A EC EtherCAT Note) Symbol Description
SY5000/7000 SY50M-15-1A PN PROFINET Note) 1 PNP (Negative common)
∗ Part number is for one assembly. Note) Cannot be communicated 2 NPN (Positive common)
with the EX600-HT1-.
213
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View Series SY3000/5000/7000

Valve
Manifold Parts No.
t EX600 digital input unit

Sub-plate
EX600 DX P B
Input type Number of inputs, open circuit detection, and connector
Symbol Description Symbol Number of inputs Open circuit detection Connector

Plug-in
P PNP B 8 No M12 connector (5 pins) 4 pcs.
N NPN C 8 No M8 connector (3 pins) 8 pcs.
C1 8 Yes M8 connector (3 pins) 8 pcs.
D 16 No M12 connector (5 pins) 8 pcs.
E 16 No D-sub connector (25 pins) Note 1) 2)
F 16 No Spring type terminal block (32 pins) Note 1) 2)

t EX600 digital output unit

Metal Base
EX600 DY P B
Output type Number of outputs and connector
Symbol Description Symbol Number of outputs Connector
P PNP B 8 M12 connector (5 pins) 4 pcs.

Plug-in
N NPN E 16 D-sub connector (25 pins) Note 1) 2)
F 16 Spring type terminal block (32 pins) Note 1) 2)

t EX600 digital input/output unit


EX600 DM P E

Manifold Exploded View


Type 50, 51, 52
Input/Output type Number of inputs/outputs and connector
Symbol Description Symbol Number of inputs Number of outputs Connector
P PNP E 8 8 D-sub connector (25 pins) Note 1) 2)
N NPN F 8 8 Spring type terminal block (32 pins) Note 1) 2)

t EX600 analog input/output unit

Connector Connecting Base


EX600 AX A
Analog input/output Number of input channels and connector
Symbol Description Symbol Number of input channels Connector
AX Analog input A 2 channels M12 connector (5 pins) 2 pcs.∗
AY Analog output ∗ Refer to Notes 1) and 2) below for AY.

t EX600 analog input/output unit

Plug-in
EX600 AM B
Analog input/output Number of input/output channels and connector

Manifold Exploded View


Symbol Number of input channels Number of output channels Connector

Type 10, 11, 12


M12 connector (5 pins)
B 2 channels 2 channels 4 pcs. Note 1) 2)

y EX600 end plate


EX600 ED 2
Power connector Mounting
Plug Assembly Part No.

Symbol Connector Symbol Description


One-touch Fittings/

2 M12 (5 pins) Nil Without DIN rail mounting bracket


3 7/8 inch (5 pins) 3 With DIN rail mounting bracket

u Clamp bracket for EX600


Manifold Options

EX600 ZMA3
Enclosed parts
Round head screw with washer (M4 x 20) 1 pc.
P-tight screw (4 x 14) 2 pcs. Note 1) Cannot be communicated with the EX600-HT1- (Old version of the Handheld Terminal).
Note 2) Cannot be connected with the EX600-SPR1, EX600-SPR2, EX600-SDN1, or EX600-SDN2.

214
Series SY3000/5000/7000
Wiring
EX250 Manifold exploded view

q
U side

w
r a
Tension
t bolt

y
Holding screw D side

e Clamp bracket assembly Refer to pages 219 to 222


It is mounted only for the DIN rail for details about common parts.
mounting type.
The holding screws of the clamping
bracket is tightened at two points.
(Tightening torque of holding screw:
1.03 lbf·ft (1.4 N·m))
Manifold Parts No.
q SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series
∗ For bottom ported, the symbol is nil.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000
Pilot, Silencer/Piping type Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot type Built-in Piping C8 ø8  — — Side/Bottom/
Symbol Internal External silencer direction C10 ø10 —  — Top ported
C12 ø12 — —  Metric size
Nil  — —
S  —  Side
N9 ø5/16"  — — Side/Bottom/
R —  — N11 ø3/8" —  — Top ported
N13 ø1/2" — —  Inch size
V  — —
L8 ø8  — —
Downward elbow Upward elbow

RV —  — Top Side ported


VP  — ∗ L10 ø10 —  — Metric size
B  — — L12 ø12 — — 
BS  —  Bottom
LN9 ø5/16"  — —
Side ported
SUP/EXH block assembly (D side) BR —  — LN11 ø3/8" —  — Inch size
accessories and the number of accessories LN13 ø1/2" — — 
∗ For silencer (supply side). E port is plugged. B8 ø8  — —
Side ported
Accessories SY3000 SY5000
SY7000
Note) “B” for bottom ported can be selected for B10 ø10 —  — Metric size
the SY5000/7000 series. B12 ø12 — — 
a Tension bolt None Note) 3 pcs.
BN9 ø5/16"  — —
Side ported
Note) Since the nuts are embedded in the SUP/EXH block. BN11 ø3/8" —  — Inch size
BN13 ø1/2" — — 
w EX250 SI unit 00 Note) Plug 
P/E port entry on one
 
side or Top ported
EX250 S DN1 Note) It can be selected only if no symbol or “S” or “V” or “B” is
selected for the pilot and the piping.

Communication protocol r Input block


DN1 DeviceNet™ (Negative common)
PR1
MJ2
PROFIBUS DP (Negative common)
CC-Link (Positive common)
EX250 IE 1
AS3 AS-Interface (8 in/8 out, 31 slave modes, 2 isolated common type) (Negative common) Block type
AS5 AS-Interface (4 in/4 out, 31 slave modes, 2 isolated common type) (Negative common) 1 M12 connector, 2 inputs
AS7 AS-Interface (8 in/8 out, 31 slave modes, 1 common type) (Negative common) 2 M12 connector, 4 inputs
AS9 AS-Interface (4 in/4 out, 31 slave modes, 1 common type) (Negative common) 3 M8 connector, 4 inputs
CA1A CANopen (Negative common)
EN1 EtherNet/IP™ (Negative common) t EX250 end plate assembly

eClamp bracket assembly EX250 EA1


∗ With mounting screws (2 pcs. of M3 x 10)
Series Part no.
SY3000 SY30M-15-1A y Clamp bracket assembly for EX250 SI unit
SY5000/7000 SY50M-15-1A
∗ Part number is for one assembly. SY30M 15 3A
215 ∗ Part number is for one assembly.
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View Series SY3000/5000/7000

Valve
Wiring
EX260 Manifold exploded view
q U side

Sub-plate
a

Plug-in
Tension
bolt

Holding screw
e Clamp bracket assembly
It is mounted only for the DIN rail mounting type. D side Refer to pages 219 to 222

Metal Base
The holding screws of the clamping bracket is tightened
for details about common parts.
at two points. (Tightening torque of holding screw: 1.03 lbf·ft (1.4 N·m))

Manifold Parts No.

Plug-in
qSUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series
∗ For bottom ported, the symbol is nil.
3 SY3000

Manifold Exploded View


5 SY5000 P, E port size (One-touch fittings)

Type 50, 51, 52


7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type
C8 ø8  — — Side/Bottom/
Pilot type Built-in Piping
Symbol Internal External silencer direction C10 ø10 —  — Top ported
C12 ø12 — —  Metric size
Nil  — — N9 ø5/16"  — — Side/Bottom/
S  —  Side N11 ø3/8" —  — Top ported
R —  — N13 ø1/2" — —  Inch size
V  — — L8 ø8  — —
Downward elbow Upward elbow

RV —  — Top Side ported

Connector Connecting Base


L10 ø10 —  —
VP  — ∗ L12 ø12 — — 
Metric size
SUP/EXH block assembly (D side) B  — —
accessories and the number of accessories LN9 ø5/16"  — —
BS  —  Bottom LN11 ø3/8" —  —
Side ported
SY3000 SY5000 BR —  — Inch size
Accessories
SY7000 LN13 ø1/2" — — 
∗ For silencer (supply side). E port is B8 ø8  — —
aTension bolt None Note) 3 pcs. plugged. Side ported
B10 ø10 —  — Metric size
Note) Since the nuts are embedded in the Note) “B” for bottom ported can be B12 ø12 — — 
SUP/EXH block. selected for the SY5000/7000 BN9 ø5/16"  — —
series. Side ported
BN11 ø3/8" —  — Inch size
w EX260 SI unit BN13 ø1/2" — — 

Plug-in
P/E port entry on one
00 Note) Plug  
EX260 S PR1

side or Top ported
Note) It can be selected only if no symbol or “S” or “V” or “B” is

Manifold Exploded View


selected for the pilot and the piping.
Communication protocol

Type 10, 11, 12


Symbol Protocol Number of
outputs SI unit output polarity Communication
connector Manifold symbol Symbol Protocol Number of
outputs SI unit output polarity Communication
connector Manifold symbol
DN1 32
Source/PNP (Negative common) QAN EC1 32
Source/PNP (Negative common) DAN
DN2 DeviceNet™ Sink/NPN (Positive common)
M12
QA EC2 EtherCAT Sink/NPN (Positive common)
M12
DA
DN3 16
Source/PNP (Negative common) QBN EC3 16
Source/PNP (Negative common) DBN
DN4 Sink/NPN (Positive common) QB EC4 Sink/NPN (Positive common) DB
PR1 32
Source/PNP (Negative common) NAN PN1 32
Source/PNP (Negative common) FAN
PR2 Sink/NPN (Positive common)
M12
NA PN2 PROFINET Sink/NPN (Positive common)
M12
FA
PR3 16
Source/PNP (Negative common) NBN PN3 16
Source/PNP (Negative common) FBN
PR4 PROFIBUS DP Sink/NPN (Positive common) NB PN4 Sink/NPN (Positive common) FB
Plug Assembly Part No.

PR5 Source/PNP (Negative common) EN1 Source/PNP (Negative common)


One-touch Fittings/

NCN EAN
32 32
PR6 Sink/NPN (Positive common) NC EN2 EtherNet/IP™ Sink/NPN (Positive common) EA
Source/PNP (Negative common) D-sub M12
Note)
PR7 16
NDN EN3 16
Source/PNP (Negative common) EBN
PR8 Sink/NPN (Positive common) ND EN4 Sink/NPN (Positive common) EB
MJ1 32
Source/PNP (Negative common) VAN
MJ2 CC-Link
Sink/NPN (Positive common)
M12
VA
MJ3 16
Source/PNP (Negative common) VBN
MJ4
Manifold Options

Sink/NPN (Positive common) VB


Note) Enclosure is IP40 when the communication connector is D-sub.

e Clamp bracket assembly


Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A
∗ Part number is for one assembly. 216
Series SY3000/5000/7000
Wiring
EX126 Manifold exploded view

q
U side
w

a
Tension
bolt
e

Mounting screw for D side


connecting parts
(Tightening torque: Refer to pages 219 to 222
Holding screw
0.59 lbf·ft (0.8 N·m)) for details about common parts.
r t Clamp bracket assembly
It is mounted only for the DIN rail mounting type.
The holding screws of the clamping bracket is
tightened at two points.
(Tightening torque of holding screw: 1.03 lbf·ft (1.4 N·m))

Manifold Parts No.


qSUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series
∗ For bottom ported, the symbol is nil.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type
C8 ø8  — — Side/Bottom/
Pilot type Built-in Piping
Symbol silencer direction
C10 ø10 —  — Top ported
Internal External Metric size
C12 ø12 — — 
Nil  — — N9 ø5/16"  — — Side/Bottom/
S  —  Side N11 ø3/8" —  — Top ported
R —  — N13 ø1/2" — —  Inch size
V  — — L8 ø8  — —
Downward elbow Upward elbow

RV —  — Top L10 ø10 —  —


Side ported
VP  — ∗ L12 ø12 — — 
Metric size
B  — — LN9 ø5/16"  — —
BS  —  Bottom LN11 ø3/8" —  —
Side ported
BR —  — Inch size
LN13 ø1/2" — — 
∗ For silencer (supply side). E port is plugged. B8 ø8  — —
Note) “B” for bottom ported can be selected for Side ported
B10 ø10 —  — Metric size
the SY5000/7000 series. B12 ø12 — — 
SUP/EXH block assembly (D side)
BN9 ø5/16"  — —
Side ported
BN11 ø3/8" —  — Inch size
accessories and the number of accessories BN13 ø1/2" — — 
Accessories SY3000 SY5000 00 Note) Plug
P/E port entry on one
  
SY7000 side or Top ported
a Tension bolt None Note) 3 pcs. Note) It can be selected only if no symbol or “S” or “V” or “B” is
Note) Since the nuts are embedded in the SUP/EXH block. selected for the pilot and the piping.

wEX126 SI unit r Clamp bracket assembly for EX126 SI unit

EX126D SMJ1 SY30M 15 4A


∗ CC-Link (Positive common) ∗ Part number is for one assembly.

t Clamp bracket assembly


eTerminal block plate assembly Series Part no.
VVQC1000 74A 2 SY3000
SY5000/7000
SY30M-15-1A
SY50M-15-1A
∗ Part number is for one assembly.
217
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View Series SY3000/5000/7000

Valve
Wiring
EX120 Manifold exploded view

q
U side

Sub-plate
w

Plug-in
a
Tension
bolt

Metal Base
D side

Holding screw Refer to pages 219 to 222


e Clamp bracket assembly for details about common parts.
It is mounted only for the DIN rail mounting type.

Plug-in
The holding screw of the clamping bracket is
tightened at one point.
(Tightening torque of holding screw: 1.03 lbf·ft (1.4 N·m))

Manifold Parts No.

Manifold Exploded View


Type 50, 51, 52
q SUP/EXH block assembly
Mounting
SY 3 0M 1 16A C8 Nil Direct mounting
D0 DIN rail mounting (Without DIN rail)
Series
∗ For bottom ported, the symbol is nil.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type

Connector Connecting Base


Pilot type
C8 ø8  — — Side/Bottom/
Built-in Piping
Symbol
Internal External silencer direction
C10 ø10 —  — Top ported
C12 ø12 — —  Metric size
Nil  — —
N9 ø5/16"  — — Side/Bottom/
S  —  Side N11 ø3/8" —  — Top ported
R —  —
N13 ø1/2" — —  Inch size
V  — —
L8 ø8  — —
Downward elbow Upward elbow

RV —  — Top L10 ø10 —  —


Side ported
VP  — ∗ Metric size
L12 ø12 — — 
B  — —
LN9 ø5/16"  — —
BS — Bottom Side ported

Plug-in
 
LN11 ø3/8" —  —
BR —  —
LN13 ø1/2" — — 
Inch size
∗ For silencer (supply side). E port is plugged. B8 ø8  — —
Note) “B” for bottom ported can be selected for Side ported
B10 ø10 —  —

Manifold Exploded View


the SY5000/7000 series. Metric size
SUP/EXH block assembly (D side) B12 ø12 — — 

Type 10, 11, 12


BN9 ø5/16"  — —
accessories and the number of accessories Side ported
BN11 ø3/8" —  — Inch size
Accessories SY3000 SY5000
SY7000
BN13 ø1/2" — — 
P/E port entry on one
aTension bolt None Note) 3 pcs. 00 Note) Plug    side or Top ported
Note) Since the nuts are embedded in the SUP/EXH block. Note) It can be selected only if no symbol or “S” or “V” or “B” is
selected for the pilot and the piping.
w EX120 SI unit
EX120 S DN1
Plug Assembly Part No.
One-touch Fittings/

Communication protocol
DN1 DeviceNet™ (Positive common)
CS1 OMRON Corp.: CompoBus/S (16 outputs) (Positive common)
CS2 OMRON Corp.: CompoBus/S (8 outputs) (Positive common)
MJ1 CC-Link (Positive common)
Manifold Options

CM1 CompoNet™ NPN (Positive common)


CM3 CompoNet™ PNP (Negative common)

e Clamp bracket assembly


Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A
∗ Part number is for one assembly.
218
Series SY3000/5000/7000
Manifold Exploded View (Common Parts)
y Valve mounting screw
Caution (SY7000: 3 pcs.)
B SUP/EXH end block assembly
(Includes a.)
Tightening torque Details Page 222 U side

M2: 0.12 lbf·ft (0.16 N·m) (SY3000)


M3: 0.59 lbf·ft (0.8 N·m) (SY5000/7000)

Note) Refer to page 220 for order numbers.


a Tension bolt

SUP blocking disk assembly


Refer to “Manifold Options” A-w
A-q ( Tightening torque: 0.59 lbf ft (0.8 N·m)
SY3000: 2 pcs.
SY5000/7000: 3 pcs.
)
on page 231.
A-e
A-r

u DIN rail
It is mounted only for
the DIN rail mounting
type (with DIN rail.)

A Manifold block
assembly
D side Details Page 221
EXH blocking disk assembly
t Refer to “Manifold Options”
Tie-rod on page 231. Holding screw
(SY5000/7000: 3 pcs.)
i Clamp bracket assembly
It is mounted only for the DIN
rail mounting type. (Tightening
∗ The figures show the SY3000 series. torque of holding screw: 1.03 lb·ft (1.4 N·m))

Type 10, 11, 12: How to Increase Connector Type Manifold

1 Loosen the U-side tension bolt a, and remove the B <For SY3000>
SUP/EXH end block assembly.

2 Screw in r tie-rods for additional stations to


the t tie-rod of the manifold.
Screw them in until there is no gap Manifold block assembly∗
between the tie-rods.
q Base gasket

3 Connect the A manifold block assembly and B w Connector


SUP/EXH end block assembly to be added, and gasket
tighten the tension bolt a.
r Tie-rod for
additional
e Manifold stations
Tightening torque for tension bolt a (M3): 0.59 lbf ft (0.8 N·m)
block gasket

Caution
1. Be sure to shut off the power and air supplies before Gaskets are mounted.
disassembly.
Furthermore, since air may remain inside the actuator, piping ∗ Manifold block assembly
and manifold, confirm that the air is completely exhausted No. Description Q'ty Note
before performing any work. For base, connector
qwe Gasket 3
2. When disassembly and assembly are performed, air leakage and manifold block
may result if the tightening of the tension bolt is inadequate.
Tie-rod for SY3000 2 pcs.
r additional stations SY5000 3 pcs.
SY7000 3 pcs.
Refer to page 220 for ordering single unit.
219
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View Series SY3000/5000/7000

Valve
For SS5Y3-10/11/12, SS5Y5-(M)10/11/12, SS5Y7-(M)10/11/12

No. Description SY3000 SY5000 SY7000 Note

Sub-plate
Base gasket Part numbers shown on the left are
A-q
(for connector connecting base) SY30M-9-1A SY50M-9-1A SY70M-9-1A for 10 valves. (10 pcs.)
Manifold block assembly

A-w Connector gasket SX3000-146-2 Supplied individually.


Manifold block gasket SY30M-9-2 SY50M-9-2 SY70M-9-2

Plug-in
A-e Supplied individually.
Note 2)
2 pcs. supplied (SY3000),
SY3000/5000/7000 SY30M-49-2-A SV2000-55-2A-A SY70M-49-2-A 3 pcs. supplied (SY5000/7000)
stations Note 1)
Tie-rod for
additional

For mixed mounting of SY3000/5000:


A-r
except A, B port size ø8, ø5/16" — SY50M-49-2-A — 3 pcs. supplied.

For mixed mounting of SY3000/5000:


A, B port size ø8, ø5/16" — SV2000-55-2A-A — 3 pcs. supplied.

Metal Base
: Manifold stations (2 stations to 24
SY3000/5000/7000 VVQC1000-TR- SV2000-55-1--A SY70M-49-1--A stations) 2 pcs. supplied (SY3000),
t Tie-rod 3 pcs. supplied (SY5000/7000)
Mixed mounting type manifold
(for mounting only SY3000 on — SY50M-49-1--A SY70M-49-1--A 3 pcs. supplied.

Plug-in
SY5000 manifolds)

Round head combination screw


SY3000-23-24A SY5000-221-1A SY7000-221-1A Part numbers shown on the left are as follows.
Valve (M2 x 32) (M3 x 32.5) (M3 x 36.5) SY3000/5000:
y mounting for 10 valves (20 pcs. included)
screw Hexagon socket head cap screw
SY3000-222-1A SY5000-222-1A SY7000-222-1A SY7000:
(M2 x 32) (M3 x 32.5) (M3 x 36.5) for 10 valves (30 pcs. included)

Manifold Exploded View


u DIN rail VZ1000-11-1- VZ1000-11-4- Refer to page 225.

Type 50, 51, 52


i Clamp bracket assembly (for connector connecting base) SY30M-15-1A SY50M-15-1A Supplied individually.
Note 1) For the SS5Y5/7-(M)10/11/12, the manifold cannot be assembled with only the tie-rod for additional stations. Be sure to use the tie-rod t.
Note 2) For the SY7000, order this part number also when the SY5000 is mounted.

Connector Connecting Base


Plug-in
Manifold Exploded View
Type 10, 11, 12
Plug Assembly Part No.
One-touch Fittings/
Manifold Options

220
Series SY3000/5000/7000
Manifold Parts No.
AManifold block assembly
SY 3 0M 2 1 D A C6
Series A, B port size (One-touch fittings)
3 SY3000 Symbol A, B port SY3000 SY5000 SY7000 Note Symbol A, B port SY3000 SY5000 SY7000 Note
5 SY5000 C2 ø2  — — L4 ø4   — Side
7 SY7000 C3 ø3.2  — — Side/ L6 ø6    ported

Upward elbow
C4 ø4    Bottom L8 ø8 — Note)   Metric
Piping direction C6 ø6    ported L10 ø10 — —  size
1 Side/Top ported C8 ø8 — Note)   Metric LN3 ø5/32"  — — Side
2 Bottom ported C10 ø10 — —  size LN7 ø1/4"   — ported
Note) “2” for bottom ported can
C12 ø12 — —  LN9 ø5/16" — Note)  — Inch
be selected for the
N1 ø1/8"  — — Side/ LN11 ø3/8" — —  size
SY5000/7000 series.
N3 ø5/32"   — Bottom B4 ø4   — Side

Downward elbow
N7 ø1/4"    ported B6 ø6    ported
N9 ø5/16" — Note)   Inch B8 ø8 — Note)   Metric
N11 ø3/8" — —  size B10 ø10 — —  size
Note) Refer to mixed mounting type for ø8, ø5/16". BN3 ø5/32"  — — Side
Single wiring BN7 ø1/4"   — ported
Marked with ß BN9 ø5/16" — Note)  — Inch
BN11 ø3/8" — —  size
00 Plug    Top ported
Wiring type
S Single wiring
D Double wiring A Manifold (All parts inside are included.)
block assembly
q Base gasket
A Mixed mounting of the SY3000/5000 w Connector r Tie-rod for
gasket
Manifold block assembly for mounting the SY3000 additional
stations
SY50M 2 3 D A C6
Piping direction A, B port size (One-touch fittings)
3 Side/Top ported Symbol A, B port Note Symbol A, B port Note
4 Bottom ported C2 ø2 L4 ø4 Side ported
Downward elbow Upward elbow

Side/Bottom
C3 ø3.2
ported L6 ø6 Metric size
Wiring type C4 ø4 Metric size LN3 ø5/32" Side ported
S Single wiring C6 ø6 LN7 ø1/4" Inch size
D Double wiring N1 ø1/8" Side/Bottom B4 ø4 Side ported
N3 ø5/32" ported B6 ø6 Metric size
N7 ø1/4" Inch size BN3 ø5/32" Side ported
BN7 ø1/4" Inch size
00 Plug Top ported Gaskets are mounted.

A Mixed mounting of the SY3000/5000 e Manifold block gasket


Manifold block assembly for mounting the SY3000 for ø8, ø5/16"
(A manifold block assembly for mounting the SY3000 valves on the Manifold block assembly accessories and
SY5000 manifolds at A, B port size: ø8, ø5/16") the number of accessories

SY50M 2 5 D A C8 Accessories SY3000 SY5000


SY7000 Note)
q Base gasket 1 pc.
Piping direction A, B port size (One-touch fittings) w Connector gasket 1 pc.
5 Side ported Symbol A, B port Note e Manifold block gasket 1 pc.
6 Bottom ported C8 ø8 Side/Bottom ported Metric size rTie-rod assembly for additional stations 2 pcs. 3 pcs.
N9 ø5/16" Side/Bottom ported Inch size Note) Including mixed mounting type
Wiring type L8 Upward ø8 Side ported Metric size
S Single wiring LN9 elbow ø5/16" Side ported Inch size
D Double wiring B8 Downward ø8 Side ported Metric size
BN9 elbow ø5/16" Side ported Inch size

A Mixed mounting of the SY5000/7000


Manifold block assembly for mounting the SY5000
SY70M 2 3 DA C10
Piping direction A, B port size (One-touch fittings)
3 Side/Bottom ported Symbol A, B port Note Symbol A, B port Note Symbol A, B port Note
4 Bottom ported C6 ø6 L6 ø6 B6 ø6
Downward elbow
Upward elbow

Side/Bottom
C8 ø8
ported L8 ø8 Side ported B8 ø8 Side ported
Wiring type C10 ø10 Metric size L10 ø10 Metric size B10 ø10 Metric size
S Single wiring C12 ø12 L12 ø12 B12 ø12
D Double wiring N7 ø1/4" Side/Bottom Side ported Side ported
N9 ø5/16" ported LN11 ø3/8"
Inch size BN11 ø3/8"
Inch size
N11 ø3/8" Inch size 00 Plug Top ported
221
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View Series SY3000/5000/7000

Valve
Manifold Parts No.
B SUP/EXH end block assembly

Sub-plate
SY 3 0M 3 1A C8
Series Mounting

Plug-in
3 SY3000 Nil Direct mounting
5 SY5000 D0 DIN rail mounting (Without DIN rail)
7 SY7000 ∗ For bottom ported, the symbol is nil.

Pilot, Silencer/Piping type


Pilot type Built-in Piping

Metal Base
Symbol
Internal External silencer direction
Nil  — — B SUP/EXH end block assembly
(Includes a.)
S  —  Side
R —  —
V  — —
RV

Plug-in
—  — Top
VP  — ∗
B  — —
BS —  Bottom
BR

—  —
A-e
a Tension bolt

( )
∗ For silencer (supply side). E port is plugged.
Tightening torque:

Manifold Exploded View


Note) “B” for bottom ported can be selected for the
0.59 lbf ft (0.8 N·m)

Type 50, 51, 52


SY5000/7000 series.
SY3000: 2 pcs.
SY5000/7000: 3 pcs.

P, E port size (One-touch fittings)


Symbol P, E port SY3000 SY5000 SY7000 Note
C8 ø8  — —
Side/Bottom/Top ported
C10 ø10 —  — Metric size
C12 ø12 — —  SUP/EXH end block assembly accessories and the number of accessories
N9

Connector Connecting Base


ø5/16"  — —
Side/Bottom/Top ported Accessories SY3000 SY5000/7000
N11 ø3/8" —  — Inch size aTension bolt 2 pcs. 3 pcs.
N13 ø1/2" — —  A-eManifold block gasket 1 pc.
L8 ø8  — —
Downward elbow Upward elbow

Side ported Gasket is mounted.


L10 ø10 —  — Metric size
L12 ø12 — — 
LN9 ø5/16"  — —
Side ported
LN11 ø3/8" —  — Inch size
LN13 ø1/2" — — 
B8 ø8  — —
Side ported
B10 ø10 —  —

Plug-in
Metric size
B12 ø12 — — 
BN9 ø5/16"  — —
Side ported
BN11 ø3/8" —  — Inch size
BN13

Manifold Exploded View


ø1/2" — — 
P/E port entry on one side

Type 10, 11, 12


00 Note) Plug   
or Top ported
Note) It can be selected only if no symbol or “S” or “V” or “B” is selected for
the pilot and the piping.

Plug Assembly Part No.


One-touch Fittings/
Manifold Options

222
Series SY3000/5000/7000

Manifold Parts No.


 Cover assembly/Silencer cover assembly/Port block assembly for SUP/EXH (end) block assembly
Mounting screw (M3)

Cover assembly
(Internal pilot) SY 3 0M 4 1A
Dent for positioning

Silencer cover assembly


(Internal pilot, Built-in silencer) SY 3 0M 5 1A

X, PE port

Port block assembly


(Side/Bottom ported, External pilot) SY 3 0M 6 1AR 00
X, PE port One-touch fitting type
Symbol X, PE port SY3000 SY5000 SY7000
ø4   —
Nil Metric size
ø6 — — 
ø5/32"   —
P port U Inch size
ø1/4" — — 
E port

Port block assembly


(Top ported, Internal pilot, for silencer SY 3 0M 6 3 AV C8
(supply side))
P port
E port
X, PE port
Port block assembly
(Top ported, Internal/External pilot) SY 3 0M 6 1A V C8
Series Pilot type
3 SY3000 Nil Internal pilot
5 SY5000 R External pilot
∗ Cover assembly, silencer cover assembly 7 SY7000
and port block assembly are included in the
SUP/EXH (end) block assembly, but they P, E port size (One-touch fittings)
need to be ordered for piping direction Symbol P, E port SY3000 SY5000 SY7000
change. C8 ø8  — —
C10 ø10 —  —
Tightening torque for mounting screw
C12 ø12 — — 
SY3000/5000 (M3): 0.59 lbf ft (0.8 N·m)
N9 ø5/16"  — —
SY7000 (M4): 1.03 lbf ft (1.4 N·m) N11 ø3/8" —  —
N13 ø1/2" — — 
00 Note) Plug
Caution  
Note) Cannot be selected for the SY0M-6-3AV- and


1. Be sure to shut off the power and air supplies before SY0M-6-1ARV-.
disassembly.
Furthermore, since air may remain inside the actuator, piping
and manifold, confirm that the air is completely exhausted
before performing any work.
2. When disassembly and assembly are performed, air leakage
may result if the tightening of the cover and port block
assemblies are inadequate.

223
Series SY3000/5000/7000
One-touch Fittings

Valve
and Plug Assembly/Part No.
Refer to “Changing One-touch Fittings” on page 248 for replacement method.
 One-touch fittings

Sub-plate
Port size SY3000 SY5000 SY7000
ø2 VVQ1000-50A-C2 — —
ø3.2 VVQ1000-50A-C3 — —
ø4 VVQ1000-50A-C4 VVQ1000-51A-C4 —

Plug-in
ø6 Straight type VVQ1000-50A-C6 VVQ1000-51A-C6 VVQ2000-51A-C6
ø8 — VVQ1000-51A-C8 VVQ2000-51A-C8
ø10 — — VVQ2000-51A-C10
ø12 — — KQ2H12-17-X224
Metric size

ø4 SZ3000-73-1A-L4 SZ3000-74-1A-L4 —
ø6 SZ3000-73-1A-L6 SZ3000-74-1A-L6 SZ3000-83-1A-L6
ø8 Elbow type — SZ3000-74-1A-L8 SZ3000-83-1A-L8

Metal Base
ø10 — — SZ3000-83-1A-L10
ø12 — — KQ2L12-17N-X224
ø4 SZ3000-73-2A-L4 SZ3000-74-2A-L4 —
A, B port Note1)

ø6 SZ3000-73-2A-L6 SZ3000-74-2A-L6 SZ3000-83-2A-L6

Plug-in
ø8 Long elbow type — SZ3000-74-2A-L8 SZ3000-83-2A-L8
ø10 — — SZ3000-83-2A-L10
ø12 — — KQ2W12-17N-X224
ø1/8" VVQ1000-50A-N1 — —

Manifold Exploded View


ø5/32" VVQ1000-50A-N3 VVQ1000-51A-N3 —

Type 50, 51, 52


ø1/4" Straight type VVQ1000-50A-N7 VVQ1000-51A-N7 VVQ2000-51A-N7
ø5/16" — VVQ1000-51A-N9 VVQ2000-51A-N9
ø3/8" — — VVQ2000-51A-N11
Inch size

ø5/32" KJL03-95-X224 — —
ø1/4" KJL07-95-X224 KQ2L07-14-X224 —
Elbow type
ø5/16" — KQ2L09-14-X224 —
ø3/8" — — KQ2L11-14-X224

Connector Connecting Base


ø5/32" KJL03-95-X225 — —
ø1/4" KJL07-95-X225 KQ2L07-14-X225 —
Long elbow type
ø5/16" — KQ2L09-14-X225 —
ø3/8" — — KQ2L11-14-X225
ø8 VVQ1000-51A-C8 — —
ø10 Straight type — VVQ2000-51A-C10 —
ø12 — — VVQ4000-50B-C12
Metric size

ø8 SZ3000-74-1A-L8 — —

Plug-in
ø10 Elbow type — SZ3000-83-1A-L10 —
ø12 — KQ2L12-19N-X224
ø8 SZ3000-74-2A-L8 — —

Manifold Exploded View


ø10 Long elbow type — SZ3000-83-2A-L10 —

Type 10, 11, 12


P, E port

ø12 — — KQ2W12-19N-X224
ø5/16" VVQ1000-51A-N9 — —
ø3/8" Straight type — VVQ2000-51A-N11 —
ø1/2" — — VVQ4000-50B-N13
Inch size

ø5/16" KQ2L09-14-X224 — —
ø3/8" Elbow type — KQ2L11-14-X224 —
ø1/2" — — KQ2L13-19N-X224
Plug Assembly Part No.
One-touch Fittings/

ø5/16" KQ2L09-14-X225 — —
ø3/8" Long elbow type — KQ2L11-14-X225 —
ø1/2" — — KQ2W13-19N-X224
Note 1) A and B ports (ø8 and ø5/16") of the SY3000 and 5000 mixed mounting type are the same as those of the SY5000.
Note 2) The basic order unit of the One-touch fitting part number is 1 pc. Additionally, when performing the piping in the same orientation using the elbow type,
please order “elbow type” or “long elbow type” appropriately.
Manifold Options

 Plug assembly
SY3000 SY5000 SY7000
A, B port VVQ0000-58A VVQ1000-58A VVQ2000-58A
P, E port VVQ1000-58A VVQ2000-58A SY9000-62-1A
Note) The basic order unit of the plug assembly part number is 1 pc.
224
Series SY3000/5000/7000
Manifold Options
 DIN rail dimensions/weight for the SY3000 Plug-in metal base and
the SY3000/5000 Plug-in connector connecting base
VZ1000-11-1-
∗ After confirming the L3 dimension in the dimensions table of each series, refer to the DIN rail dimensions table below and
specify the number in the box .
L
8 (7.5)
5.5

(35)
(25)
Rail mounting hole pitch 12.5

No. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
L dimension 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 273 285.5 298 310.5 323
Weight (g) 17.6 19.9 22.1 24.4 26.6 28.9 31.1 33.4 35.6 37.9 40.1 42.4 44.6 46.9 49.1 51.4 53.6 55.9 58.1
No. 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
L dimension 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 523 535.5 548 560.5
Weight (g) 60.4 62.5 64.9 67.1 69.4 71.6 73.9 76.1 78.4 80.6 82.9 85.1 87.4 89.6 91.9 94.1 96.4 98.6 100.9
No. 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56
L dimension 573 585.5 598 610.5 623 635.5 648 660.5 673 685.5 698 710.5 723 735.5 748 760.5 773 785.5 798
Weight (g) 103.1 105.4 107.6 109.9 112.1 114.4 116.6 118.9 121.1 123.4 125.6 127.9 130.1 132.4 134.6 136.9 139.1 141.4 143.6
No. 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71
L dimension 810.5 823 835.5 848 860.5 873 885.5 898 910.5 923 935.5 948 960.5 973 985.5
Weight (g) 145.9 148.1 150.4 152.6 154.9 157.1 159.4 161.6 163.9 166.1 168.4 170.6 172.9 175.1 177.4

 DIN rail dimensions/weight for the SY5000/7000 Plug-in metal base and
the SY7000 Plug-in connector connecting base
VZ1000-11-4-
∗ After confirming the L3 dimension in the dimensions table of each series, refer to the DIN rail dimensions table below and
specify the number in the box .
L
8
5.5

(35)
(25)

Rail mounting hole pitch 12.5 (10)

No. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
L dimension 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 273 285.5 298 310.5 323
Weight (g) 24.8 28 31.1 34.3 37.4 40.6 43.8 46.9 50.1 53.3 56.4 59.6 62.7 65.9 69.1 72.2 75.4 78.6 81.7
No. 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
L dimension 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 523 535.5 548 560.5
Weight (g) 84.9 88 91.2 94.4 97.5 100.7 103.9 107 110.2 113.3 116.5 119.7 122.8 126 129.2 132.3 135.5 138.6 141.8
No. 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56
L dimension 573 585.5 598 610.5 623 635.5 648 660.5 673 685.5 698 710.5 723 735.5 748 760.5 773 785.5 798
Weight (g) 145 148.1 151.3 154.5 157.6 160.8 163.9 167.1 170.3 173.4 176.6 179.8 182.9 186.1 189.2 192.4 195.6 198.7 201.9
No. 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71
L dimension 810.5 823 835.5 848 860.5 873 885.5 898 910.5 923 935.5 948 960.5 973 985.5
Weight (g) 205.1 208.2 211.4 214.5 217.7 220.9 224 227.2 230.4 233.5 236.7 239.8 243 246.2 249.3

225
Manifold Options Series SY3000/5000/7000

Valve
Caution
Tightening torque for mounting screw
M2: 0.12 lbf ft (0.16 N·m) (SY3000)
Manifold Options ∗ Refer to pages 236, 238, 240 for dimensions. M3: 0.59 lbf ft (0.8 N·m) (SY5000/7000)

 Blanking plate assembly How to Order Blanking Plate Assembly

Sub-plate
[With two mounting screws (3 pcs. for the SY7000)]
Used when valve additions are expected or for maintenance. A SY 3 0M 26 1 A
structure is in place on the blanking plate to prevent the mounting
screws from sliding. Mounting Series Option for mounting
Mounting screw
Mounting 3 SY3000 With mounting screw

Plug-in
screw (3 pcs.) Nil
screw 5 SY5000 (Round head combination screw)
(2 pcs.)
(2 pcs.)
7 SY7000 With mounting screw
B (Hexagon socket head cap screw)
(A) (B)
4 2 Base type
1 For plug-in connector connecting base
2 For plug-in metal base
5 1 3
(EA) (P) (EB)

Metal Base
SY30M-26-A (-B) SY50M-26-A (-B) SY70M-26-A (-B) Circuit diagram

 Individual SUP spacer assembly How to Order Individual SUP/EXH Spacer Assembly
[With a connector gasket, a base gasket, and two mounting screws (3 One-touch fitting
SY 3 0M 38 1 A C6

Plug-in
pcs. for the SY7000)] Straight type
When the same manifold is used for different pressures, an individual
SUP spacer assembly is used as a supply port for different pressures. One-touch fitting
Note) When selecting a One-touch fitting elbow type for a spacer Elbow type SY 3 0M 38 2 A L6
assembly, use it faced upward, since it interferes with A and B port
piping in Type 50 and Type 10 manifolds.
Series

Manifold Exploded View


3 SY3000

Type 50, 51, 52


5 SY5000
4(A)
2-position single valve 2(B) 7 SY7000
Individual SUP spacer
assembly Spacer type
Mounting 1(P') 38 Individual SUP spacer
screw 39 Individual EXH spacer
5(EA)
1(P)
3(EB) Individual SUP/EXH spacer assembly
Circuit diagram
2 Short elbow type

Connector Connecting Base


(Mounting example of a
2-position single valve) 3 Long elbow type
Base gasket Part numbers of mounting Note) Select the long elbow type for a 3-position
screw (For repairs) valve when using Type 11 and Type 12
SY3000: SY3000-23-12A (2 pcs.) downward. However,
SY5000: SY5000-221-2A (2 pcs.) Type 11 of the SY3000 series for the
SY7000: SY7000-221-2A (3 pcs.) mixed mounting of connector connecting
bases cannot be used downward.

Port size (Metric/One-touch fittings)


Connector gasket
Symbol P, E port SY3000 SY5000 SY7000

Plug-in
L4 ø4   —
 Individual EXH spacer assembly L6 ø6   
[With a connector gasket, a base gasket, and two mounting screws (3 pcs. for L8 ø8 —  
the SY7000)] L10 ø10 — — 

Manifold Exploded View


When valve exhaust affects other stations due to the circuit configuration, this L12 ø12 — — 

Type 10, 11, 12


spacer assembly is used for individual valve exhaust.
Port size (Inch/One-touch fittings)
Note) When selecting a One-touch fitting elbow type for a spacer assembly, use
Symbol P, E port SY3000 SY5000 SY7000
it faced upward, since it interferes with A and B port piping in Type 50 and
LN3 ø5/32"  — —
Type 10 manifolds.
LN7 ø1/4"   —
LN9 ø5/16" —  —
2-position single valve 4(A) LN11 ø3/8" — — 
2(B)
Individual EXH spacer
assembly
Port size (Metric/One-touch fittings)
Plug Assembly Part No.

3/5(E') Symbol P, E port SY3000 SY5000 SY7000


Mounting
One-touch Fittings/

screw C2 ø2  — —
5(EA)
1(P) C3 ø3  — —
3(EB) C4 ø4   —
Circuit diagram
C6 ø6   
(Mounting example of a
2-position single valve) C8 ø8 —  
Part numbers of mounting
C10 ø10 — — 
Base gasket screw (For repairs) C12 ø12 — — 
Manifold Options

SY3000: SY3000-23-12A (2 pcs.)


SY5000: SY5000-221-2A (2 pcs.) Port size (Inch/One-touch fittings)
SY7000: SY7000-221-2A (3 pcs.) Symbol P, E port SY3000 SY5000 SY7000
N1 ø1/8"  — —
N3 ø5/32"   —
N7 ø1/4"   
Connector gasket N9 ø5/16" —  
N11 ø3/8" — — 
226
Series SY3000/5000/7000
Caution
Tightening torque for mounting screw
M2: 0.12 lbf ft (0.16 N·m) (SY3000)
Manifold Options ∗ Refer to pages 236 to 241 for dimensions. M3: 0.59 lbf ft (0.8 N·m) (SY5000/7000)

 SUP stop valve spacer assembly with residual


pressure release valve
[With a connector gasket, a base gasket, and two mounting
screws (3 pcs. for the SY7000)] 2-position single valve
It is used to shut off the supply air to valves individually. 4(A)
2(B)
Note) Cannot be selected when the elbows are facing
upward in A and B ports in Type 10 manifolds, since they
will interfere with the piping for the spacer assembly.
EXH.
5(EA)
Series Part no. 1(P) Connector gasket
3(EB) Base gasket
SY3000 SY30M-50-1A SUP stop valve spacer assembly with residual
SY5000 SY50M-50-1A pressure release valve Mounting screw
SY7000 SY70M-50-1A Circuit diagram
(Mounting example of a Part numbers of mounting
2-position single valve) screw (For repairs)
SY3000: SY30M-56-1A (2 pcs.)
SY5000: SY50M-56-1A (2 pcs.)
SY7000: SY70M-56-1A (3 pcs.)

Valve mounting screw


[How to mount SUP stop valve spacer assembly with residual Tightening torque:
pressure release valve] Series SY3000: 0.12 lbf·ft (0.16 N·m)
Insert the SUP stop valve mounting screw from the side of the spacer assembly, and Series SY5000/7000: 0.59 lbf·ft (0.8 N·m)
mount it to the manifold. or Hexagon socket head cap screws
Nominal wrench size:
Tighten the SUP stop valve mounting screw to the specified tightening torque. Series SY3000: 1.5
Mount the valve and tighten the valve mounting screws to the specified tightening Series SY5000/7000: 2.5 Valve
torque after mounting the SUP stop valve spacer assembly with residual pressure
exhaust valve.
SUP stop valve spacer
assembly with residual pressure
Note 1) Install the plate type nut to the spacer assembly as shown in the figure if it
comes off. The SUP stop valve mounting screws can be tightened with a Plate type nut Hexagon wrench
hexagon wrench without removing the plate type nut. Nominal wrench size:
Note 2) When the elbows are facing upward in A and B ports in Type 10 manifolds, Series SY3000: 1.3
SUP stop valve mounting screw
they will interfere with the piping for the spacer assembly. Therefore, combine Series SY5000/7000: 2
Tightening torque:
the A and B ports with straight types or elbows facing downward. Series SY3000: 0.12 lbf·ft (0.16 N·m)
Series SY5000/7000: 0.59 lbf·ft (0.8 N·m)

 Double check spacer assembly with residual pressure release valve (Side/Bottom <Example>
ported) Double check spacer assembly with residual pressure release valve
[With a connector gasket, a base gasket, and two mounting screws (3 pcs. for the SY7000)] 3-position exhaust center valve
It is used to hold the intermediate position of the cylinder for a long period of time. Use a 3-position exhaust
center valve when the double check spacer assembly with residual exhaust valve is used.
It can also be used for drop prevention at the cylinder stroke end when supply residual pressure is released by
using a 2-position single/double valve.
Note) When the elbows are facing upward in A and B ports in Type 10 manifolds, they will interfere with the piping for
the spacer assembly. Therefore, combine the A and B ports with straight types or elbows facing downward.

Series Part no.


SY3000 SY30M-60-1A 4(A) 2(B) EXH.
SY5000 SY50M-60-1A 5(EA)
1(P)
SY7000 SY70M-60-1A 3(EB)
Mounting screw Circuit diagram
Intermediate stop Drop prevention (Intermediate stop: When 3-position exhaust center valve is mounted)
3 31 0
Applicable 0
SY5 40 1 SY57 2 0 1
valve 7
Double check spacer assembly with residual pressure release valve

Caution 2-position single valve

• Air leakage from the pipe between the valve and cylinder or from
the fittings will prevent the cylinder from stopping for a long period
of time. Check the leakage using neutral household detergent,
Base gasket such as dish washing soap. Also, check the cylinder’s tube
gasket, piston packing and rod packing for air leakage.
• Combining with 3-position closed center or pressure center valve
will not work.
• If the exhaust of the double check spacer is restricted too much,
4(A) 2(B) EXH.
the cylinder may not operate properly and may not stop 5(EA)
intermediately. 1(P)
Connector gasket 3(EB)
• Set the cylinder load so that the cylinder pressure will be within two Circuit diagram
Part numbers of times that of the supply pressure. (Drop prevention: When 2-position single valve is mounted)
mounting screw (For repairs)
SY3000: SY3000-23-27A (2 pcs.)
SY5000: SY5000-221-4A (2 pcs.)
SY7000: SY7000-221-4A (3 pcs.)

227
Manifold Options Series SY3000/5000/7000

Valve
Caution
Tightening torque for mounting screw
M2: 0.12 lbf ft (0.16 N·m) (SY3000)
Manifold Options ∗ Refer to pages 237, 239, 241 for dimensions. M3: 0.59 lbf ft (0.8 N·m) (SY5000/7000)

 Interface regulator
[With a connector gasket, a base gasket, and two mounting screws (3 pcs. for the SY7000)]

Sub-plate
Used when the supply pressure for each valve on the same manifold must be individually set (reduced pressure).
How to Order

SY 3 0M 05 P

Plug-in
Series Applicable valve Note 3)
3 SY3000 Nil For single, double, and 4-position
3 For 3-position
Pressure gauge option Note 1)
Note 1) In the case of the SY3000 series with a pressure gauge, when mounting on the manifold,
M1 No pressure gauge use caution that the part numbers are different between the odd no. stations and the even
05 Pressure gauge with MPa display (For odd number station) no. stations to prevent the pressure gauges from interfering with each other.

Metal Base
06 Pressure gauge with MPa display (For even number station) If using a connector connecting base M10/11/12 (mixed mounting type), you can use only
the model without a pressure gauge (M1).
N5 Pressure gauge with psi display (For odd number station) Note 2)
Note 2) As per the new Measurement Law, gauges with a psi display will only be sold to overseas
N6 Pressure gauge with psi display (For even number station) Note 2) customers.
Note 3) In the case of the SY3000 series, use caution that the part numbers will differ depending on
the one for single/double and 4- and 3-position due to the different length of solenoid
SY 5 0M 00 P

Plug-in
valves. Also, if you have selected a model with a pressure gauge, and if at least the one for
3-position is included in the same manifold, use all the ones for 3-position to prevent the
pressure gauges from interfering with each other.
Series
5 SY5000
7 SY7000 Regulating port

Manifold Exploded View


Part numbers of mounting screw (For repairs)
P 1(P) port
Pressure gauge option

Type 50, 51, 52


SY3000: SY3000-23-12A (2 pcs.)
A1 4(A) port (P controlled type, A port regulation) SY5000: SY5000-221-6A (2 pcs.)
M1 No pressure gauge B1 2(B) port (P controlled type, B port regulation) SY7000: SY7000-221-6A (3 pcs.)
00 Pressure gauge with MPa display
N0 Pressure gauge with psi display Note 2)

Mounting screw

Connector Connecting Base


Base gasket

Connector gasket

Plug-in
SY30M-05/N5- SY30M-06/N6- SY30M-M1- SY50M-00/N0- SY50M-M1- SY70M-00/N0- SY70M-M1-
(With pressure gauge/ (With pressure gauge/ (Without pressure gauge) (With pressure gauge) (Without pressure gauge) (With pressure gauge) (Without pressure gauge)
For odd number station) For even number station)

Manifold Exploded View


Specifications

Type 10, 11, 12


Interface regulator model SY30M--- SY50M-- SY70M-- Note 1) Always apply pressure from 1(P) port in the base for
Applicable valve model Note 2) SY303 (R) SY503 (R) SY703 (R) interface regulator.
Note 2) 3-position closed center and pressure center, and
Regulating port 1(P), 4(A), 2(B)
4-position dual 3-port valves are only available for
Set pressure range 0.1 to 0.7 MPa 1(P) port pressure regulation.
Maximum operating pressure 1.0 MPa Note 3) Gasket and mounting screws are included in the
Fluid Air weight.
Ambient and fluid temperature –10 to 50°C (No freezing) Note 4) ( ): Denotes the values of SY30M---3.
Plug Assembly Part No.

With pressure gauge 33(35) Note 4) 75 93


One-touch Fittings/

Weight [g] Note 3)


Without pressure gauge 27(29) Note 4) 69 87

Symbol (A)4 2(B)


(A)4 2(B)

2(B) (A)4
Manifold Options

(EA)5 3(EB)
(EA)5 3(EB) (EA)5 3(EB)

1 4(A) port regulation 2(B) port regulation


1(P) port regulation (P) 1 1
(P controlled type, A port regulation) (P) (P controlled type, B port regulation) (P)

228
Series SY3000/5000/7000 Caution
Tightening torque for mounting screw
M2: 0.12 lbf·ft (0.16 N·m) (SY3000)
Mounting Screw Part No. q (when adding optional lamination layers) M3: 0.59 lbf·ft (0.8 N·m) (SY5000/7000)

q SY3000 (M2) w SY5000 (M3) e SY7000 (M3)


Combination
Round head Hexagon socket Round head Hexagon socket Round head Hexagon socket
combination screw head cap screw combination screw head cap screw combination screw head cap screw

<Round head combination screw> SY3000- SY3000- SY5000- SY5000- SY7000- SY7000-
q: SY3000-23-24A A Valve 23-24A 222-1A 221-1A 222-1A 221-1A 222-1A
[for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves
w: SY5000-221-1A
(20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)] (30 pcs.)] (30 pcs.)]
e: SY7000-221-1A
<Hexagon socket head cap screw> SUP stop valve
A q: SY3000-222-1A spacer assembly
w: SY5000-222-1A B with residual
B e: SY7000-221-1A pressure
release valve SY30M-56-2A SY50M-56-2A SY70M-56-2A
q: SY30M-56-2A
(2 pcs.) (2 pcs.) (3 pcs.)
C w: SY50M-56-2A Individual
e: SY70M-56-2A SUP (EXH)
C spacer
assembly

A Valve
<Round head combination screw>
q: SY3000-23-33A
w: SY5000-221-5A Double check
A e: SY7000-221-5A spacer assembly SY3000- SY5000- SY7000-
B with residual 23-33A — 221-5A — 221-5A —
B pressure release (2 pcs.) (2 pcs.) (3 pcs.)
valve
C Individual
SUP (EXH)
C spacer
assembly

A Valve
<Round head combination screw>
q: SY3000-23-32A
w: SY5000-221-3A
A Individual
e: SY7000-221-3A SUP (EXH)
SY3000- SY5000- SY7000-
B B spacer 23-32A — 221-3A — 221-3A —
assembly (2 pcs.) (2 pcs.) (3 pcs.)

C Individual
EXH (SUP)
C spacer
assembly

SY3000- SY3000- SY5000- SY5000- SY7000- SY7000-


23-24A 222-1A 221-1A 222-1A 221-1A 222-1A
A Valve
<Round head combination screw> [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves
(20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)] (30 pcs.)] (30 pcs.)]
q: SY3000-23-24A
w: SY5000-221-1A SUP stop valve
e: SY7000-221-1A spacer assembly
<Hexagon socket head cap screw> B with residual
A q: SY3000-222-1A pressure
w: SY5000-222-1A release valve
B e: SY7000-222-1A
Individual
C SUP (EXH) SY30M-56-4A SY50M-56-4A SY70M-56-4A
C spacer
(2 pcs.) (2 pcs.) (3 pcs.)
q: SY30M-56-4A
D assembly
w: SY50M-56-4A
e: SY70M-56-4A
Individual
EXH (SUP)
D spacer
assembly

∗ Mounting onto a manifold follows the order explained above.


Note) The fitting for individual SUP/EXH spacers comes in a straight type only, since an elbow type would interfere with each spacer assembly when laminated.

229
Manifold Options Series SY3000/5000/7000
Caution

Valve
Tightening torque for mounting screw
M2: 0.12 lbf·ft (0.16 N·m) (SY3000)
Mounting Screw Part No. w (when adding optional lamination layers) M3: 0.59 lbf·ft (0.8 N·m) (SY5000/7000)

q SY3000 (M2) w SY5000 (M3) e SY7000 (M3)

Sub-plate
Combination
Round head Hexagon socket Round head Hexagon socket Round head Hexagon socket
combination screw head cap screw combination screw head cap screw combination screw head cap screw

<Round head combination screw> SY3000- SY3000- SY5000- SY5000- SY7000- SY7000-
23-24A 222-1A 221-1A 222-1A 221-1A 222-1A

Plug-in
q: SY3000-23-24A A Valve
w: SY5000-221-1A [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves
e: SY7000-221-1A (20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)] (30 pcs.)] (30 pcs.)]
<Hexagon socket head cap screw> SUP stop valve
q: SY3000-222-1A spacer assembly
A
w: SY5000-222-1A B with residual
e: SY7000-222-1A pressure
B release valve
SY30M-56-3A SY50M-56-3A SY70M-56-3A

Metal Base
q: SY30M-56-3A Double check (2 pcs.) (2 pcs.) (3 pcs.)
C w: SY50M-56-3A spacer
assembly with
e: SY70M-56-3A C residual
pressure
release valve

Plug-in
SY3000- SY3000- SY5000- SY5000- SY7000- SY7000-
23-24A 222-1A 221-1A 222-1A 221-1A 222-1A
<Round head combination screw> A Valve
[for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves
q: SY3000-23-24A (20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)] (30 pcs.)] (30 pcs.)]
w: SY5000-221-1A

Manifold Exploded View


e: SY7000-221-1A SUP stop valve

Type 50, 51, 52


<Hexagon socket head cap screw> spacer assembly
q: SY3000-222-1A B with residual
A w: SY5000-222-1A pressure
release valve
e: SY7000-222-1A
B Double check
spacer
q: SY30M-56-5A assembly with SY30M-56-5A SY50M-56-5A SY70M-56-5A
C w: SY50M-56-5A C residual
(2 pcs.) (2 pcs.) (3 pcs.)
e: SY70M-56-5A pressure

Connector Connecting Base


D release valve

Individual
D EXH (SUP)
spacer
assembly

A Valve

Plug-in
<Round head combination screw>
q: SY3000-23-32A
A w: SY5000-221-7A

Manifold Exploded View


e: SY7000-221-7A SY3000- SY5000- SY7000-

Type 10, 11, 12


Interface
B
regulator
23-32A — 221-7A — 221-7A —
B (2 pcs.) (2 pcs.) (3 pcs.)

C
Individual
C SUP (EXH)
spacer
assembly
Plug Assembly Part No.

∗ Mounting onto a manifold follows the order explained above.


One-touch Fittings/

Note 1) The fitting for individual SUP/EXH spacers comes in a straight type only, since an elbow type would interfere with each spacer assembly when laminated.
Note 2) When laminating an interface regulator with other options, only the combinations in the table above are possible.
Manifold Options

230
Series SY3000/5000/7000
Caution
Tightening torque for mounting screw
M2: 0.12 lbf·ft (0.16 N·m) (SY3000)
Manifold Options ∗ Refer to pages 237, 239, 241 for dimensions. M3: 0.59 lbf·ft (0.8 N·m) (SY5000/7000)

 Individual SUP block assembly Mounting screw How to Order Individual SUP/EXH Block Assembly
On the circuit of the plug-in connector
One-touch fitting
connection base, an individual SUP block
assembly can be used to supply air to a Straight type SY 3 0M 78 1 A C6
series of valves if a separate air supply is One-touch fitting
required, or if addition air is required for Elbow type SY 3 0M 78 2 A L6
additional air flow.
Individual SUP block assembly occupies 1 Series
station. 3 SY3000
Blocking disks also supplied (2 pieces). 5 SY5000 Block type
Can be used to block both sides of the 7 SY7000
78 Individual SUP block
number of stations being isolated for SUP blocking disk
assembly 79 Individual EXH block
individual air supply (as shown in
example).
<Example> Individual SUP/EXH block assembly
∗ Specify the mounting position of the
2 Short elbow type (Type 12)
block as well as the position where the D side U side
3 Long elbow type (Type 11)
SUP passage is to be blocked on the 5(EA) 5(EA)
1(P) X X 1(P) Note) Long elbow type is for the
manifold specification sheet. 3(EB) 3(EB) SY5000/7000 only.
Blocking is required for 1 or 2 positions for
1 set. (2 SUP blocking disks to block SUP Port size (Metric/One-touch fittings)
is attached to individual SUP block.) Symbol P, E port SY3000 SY5000 SY7000
∗ Electrical wiring is connected to a
L4 ø4   —
number of stations in the individual SUP L6 ø6   
block manifold. 1(P)
L8 ø8 —  
(A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B)
∗ When used in M10/11/12 (mixed L10 ø10 — — 
mounting type), select the SY50M type L12 ø12 — — 
for SS5Y5 and the SY70M type for
SS5Y7. Port size (Inch/One-touch fittings)
∗ A structure to prevent screws falling out Mounting screw Symbol P, E port SY3000 SY5000 SY7000
is in place on the individual SUP block, LN3 ø5/32"  — —
making it much harder for the mounting LN7 ø1/4"   —
screws to fall out. LN9 ø5/16" —  —
LN11 ø3/8" — — 
 Individual EXH block assembly
On the circuit of the plug-in connector
Port size (Metric/One-touch fittings)
connection base, individual EXH block
Symbol P, E port SY3000 SY5000 SY7000
assembly can be used to individually
C2 ø2  — —
exhaust series of valves when the exhaust
C3 ø3  — —
from the valves would affect a number of
EXH blocking disk C4 ø4   —
other stations. assembly C6 ø6   
Individual EXH block assembly occupies 1
C8 ø8 —  
station. <Example>
C10 ø10 — — 
Blocking disks also supplied (4 pieces). D side U side
C12 ø12 — — 
Can be used to block both sides of the 5(EA) X X 5(EA)
1(P) 1(P)
number of stations being isolated for 3(EB) X X 3(EB) Port size (Inch/One-touch fittings)
individual exhaust. (as shown in example). Symbol P, E port SY3000 SY5000 SY7000
∗ Specify the mounting position of the N1 ø1/8"  — —
block as well as the position where the N3 ø5/32"   —
EXH passage is to be blocked on the N7 ø1/4"   
manifold specification sheet. N9 ø5/16" —  
Blocking is required for 1 or 2 positions 3(R) N11 ø3/8" — — 
(A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B)
for 1 set. (2 sets of EXH blocking disks (4
pcs.) to block EXH is attached to
individual EXH block.)
∗ Electrical wiring is connected to a
number of stations in the individual EXH
block manifold.
∗ When used in M10/11/12 (mixed
mounting type), select the SY50M type
for SS5Y5 and the SY70M type for
SS5Y7.
∗ A structure to prevent screws falling out
is in place on the individual EXH block,
making it much harder for the mounting
screws to fall out.
231
Manifold Options Series SY3000/5000/7000

Valve
Manifold Options

 SUP/EXH blocking disk assembly (for connector type manifold, Type 10, 11, 12)

Sub-plate
[SUP blocking disk]
By inserting the SUP blocking disk in the pressure supply passage of the
manifold valve, can provide two different high and low pressure in one
manifold.

Plug-in
[EXH blocking disk]
By inserting the EXH blocking disk in the exhaust passage of the manifold SUP blocking EXH blocking
Series
valve, can separate the exhaust from the valve so it does not affect the disk assembly disk assembly
other valves. It can also be used for the manifold for the positive pressure SY3000 SY30M-40-1A SY30M-40-2A
and vacuum mixed manifold. (2 pcs. are required to block FA/EB both SY5000 SY50M-40-1A SY50M-40-1A
sides of the EXH.) SY7000 SY70M-40-1A SY70M-40-1A

Metal Base
 Label for blocking disk ∗ If the blocking disk assembly is ordered using
Label to indicate and confirm on the manifold where the SUP/EXH blocking the manifold specification sheet and ordered at
disk assemblies were inserted. (3 sheets each) the same time as the manifold, the position
where the blocking disk assembly is inserted will

Plug-in
SUP/EXH blocking SUP blocking EXH blocking be labeled and shipped out.
disk label disk label disk label

Manifold Exploded View


Type 50, 51, 52
Series Part no.
SY3000
SY5000 SJ3000-155-1A
SY7000

Connector Connecting Base


 Back pressure check valve assembly (Retrofit or
pre-installed type) For SY3000
It prevents cylinder malfunction caused by other valve exhaust entry.
Insert it into EA/EB port (valve mounting side) on the manifold side of a EA port
valve which is affected. It is effective when a single-acting cylinder is used. Back pressure check EB port
valve assembly
∗ When ordering assemblies incorporated with a manifold, refer to the
2 pcs. in 1 set
Ordering Example below
(when installed in all stations.)
Note) When a check valve for back pressure prevention is desired and is

Plug-in
to be installed only in certain manifold stations, clearly indicate the For SY5000/7000
part number and specify the mounting position on the manifold
specification sheet. EA port

Manifold Exploded View


<Precautions>

Type 10, 11, 12


1. The manifold installed type back pressure check valve assembly is EB port
assembly parts with a check valve structure. However, since slight air
leakage against the back pressure is allowed due to its structure, adverse
effects of the back pressure due to increase in exhaust resistance cannot Mount the back pressure check valve
be prevented if the manifold exhaust port and other exhaust ports are put assemblies on the EA and EB ports in
together for piping or if the piping diameter is narrowed. As a result, this the order shown in the figure above.
may cause the actuator and air operated equipment to malfunction. So, be
careful not to restrict the exhaust air. If the exhaust resistance becomes Series Part no.
SY3000 SY30M-24-1A
Plug Assembly Part No.

large, select a built-in valve type with rubber seal.


One-touch Fittings/

2. When the back pressure check valve assembly is mounted, please contact SY5000 SY50M-24-1A
SMC for valve flow-rate characteristics. SY7000 SY70M-24-1A

Ordering Example
SS5Y3-10F1-05B-C6·····1 set (Type 10 5-station manifold base part no.)
∗SY3201-5U1··················5 sets (2-position double part no.)
Manifold Options

∗SY30M-24-1A················5 sets (Back pressure check valve assembly part no.)


∗The asterisk denotes the symbol for assembly.

232
Series SY3000/5000/7000
Manifold Options
 Dual flow fitting (for connector connecting base, Type 10, side ported)
This is a fitting for cylinder ports which enables simultaneous actuation and increase in flow rate of valves for 2 stations.
∗ When ordering assemblies incorporated into a manifold, refer to the Ordering Example below and specify on the manifold specification sheet.

How to Order Dual Flow Fitting

SY 3 0M 120 1A C8
Series A, B port size (One-touch fittings) Clip
3 SY3000 Symbol A, B port SY3000 SY5000
5 SY5000 C8 ø8  —
Metric size
C10 ø10 — 
Dual flow fitting
N9 Inch size
ø5/16"  —
N11 ø3/8" — 
Ordering Example
SS5Y3-10F1-08B-CM
∗SY3100-5U1
∗SY30M-120-1A-C8
∗The asterisk denotes the symbol for assembly.
Note 1) Specifically for side porting for a connector
SY3000 SY5000 connecting base. Cannot be attached to bottom or
(22.8) (24.1)
top ported, or mixed mounting types that are metal
or connector connecting bases.
Note 2) When adding or changing clips, push them into the
very end of the manifold for each station. Also,
13.6

make sure to use the clip that was packed


11.1

32.1
26.3

together, as the clip and the fitting for one station


differ among products that can be used with the
SY5000.
Note 3) Not available for the SY7000 series.

 Silencer A
C
(One-touch fitting connection type)
This silencer can be mounted to the 3/5 Series Model Effective area A B C
øB
ød

(E: EXH) port of the manifold in one step. For SY3000 (ø8) AN15-C08 20 mm2 45 13 20
For SY5000 (ø10) AN20-C10 30 mm2 57.5 16.5 30.5
Body Sound absorbing material For SY7000 (ø12) AN30-C12 41 mm2 71.5 20 43.5
Note) Shipped together with the product. (Resin) (Resin sintered body)

 Plug (White) Dimensions


These are inserted in unused cylinder ports Applicable fitting size Applicable fitting size
Model A L øD Model A L øD
and P, E ports. ød (Metric size) ød (Inch size)
KJP-02 KQ2P-01
ød

2 8.2 17 3 1/8" 16 31.5 5


3.2 KQ2P-23 16 31.5 5 5/32" KQ2P-03 16 32 6
øD

4 KQ2P-04 16 32 6 1/4" KQ2P-07 18 35 8.5


A 6 KQ2P-06 18 35 8 5/16" KQ2P-09 20.5 39 10
L 8 KQ2P-08 20.5 39 10 3/8" KQ2P-11 22 43 11.5
10 KQ2P-10 22 43 12 1/2" KQ2P-13 24 46 15
12 KQ2P-12 24 45.5 14
Note) Shipped together with the product.

233
Manifold Options Series SY3000/5000/7000

Valve
Manifold Options A transparent plastic plate to put a label with the name of the function of the solenoid valve.

 Name plate (For connector connecting base)

SY3000: For SS5Y3-10 (Side ported)


SY5000: For SS5Y5-10/11 (Side/Bottom ported)

Sub-plate
SY7000: For SS5Y7-(M)10/11 (Side/Bottom ported)
SS5Y3-10
Name plate bracket assembly and name plate mounting
instructions SS5Y5- 10
11

Plug-in
Insert it into the groove on the name plate bracket onto which a
SUP/EXH (end) block is mounted, as shown in Figure 2. SS5Y7-(M) 10
11
∗ When ordering assemblies incorporated with a manifold, refer to the
Ordering Example below.
Mounting and Option
Mounting option
Symbol Printing DIN rail Direct
Yes No With Without Specified length mounting

Metal Base
AA  — — — — 
A  —  — — —
A0  — —  — —
A3  — — — For 3 stations —

Plug-in

A24  — — — For 24 stations —
BA —  — — — 
B —   — — —
B0 —  —  — —
B3 —  — — For 3 stations —

Manifold Exploded View


Type 50, 51, 52


B24 —  — — For 24 stations —
Ordering Example
Note 1) Name plates cannot be mounted onto Type 12 (Top ported) and Type 10
SS5Y3-10F1-05UR-C6AA 1 set (Side ported) mixed mounting types with top ported valves, nor onto
∗SY3200R-5U1 5 sets manifolds with optional laminated spacers.
Note 2) No name plate settings are available for the SY3000/SY5000 mixed
∗ The asterisk denotes the symbol for assembly.
mounting types. However, they are available for the SY5000/SY7000 mixed
mounting types.

Connector Connecting Base


<SY3000> <SY5000/7000>
n = 1 to 3 n = 4 to 24 n = 1 to 3 n = 4 to 24
42.3

62.5

3 1 2 3 4 5 n: Number
of stations
1 3 1 2 3 4 5 n: Number
Pitch of stations
Pitch
10.5
P = 16 (SY5000)

Plug-in
P = 19 (SY7000)
Make sure to mount
Make sure to mount
in the right direction. (20°)
in the right direction.

Manifold Exploded View


SY5000: SY50M-86-(N)

Type 10, 11, 12


Tightening torque for mounting screw (M3): Tightening torque for mounting screw (M3):
0.59 lbf·ft (0.8 N·m) 0.59 lbf·ft (0.8 N·m) SY7000: SY70M-86-(N)
SY30M-86-(N) Name plate
Mounting screw Name plate Mounting screw  is the number of stations (1 to 24).
Name plate bracket Name plate bracket
(M3)  is the number of stations (1 to 24). (M3)
SY30M-85-1A
Name plate bracket assembly
(Supplied individually) SY50M-85-1A
Align this line along (For SY5000 only) Align this line along
the end of the
Plug Assembly Part No.

Name plate insertion hole the end of the Name plate bracket assembly
One-touch Fittings/

Port block 2-position valve. (Supplied individually) 2-position valve.

Valve end Valve end


SUP/EXH end block SUP/EXH
(External pilot type) end block
Manifold Options

SUP/EXH
SUP/EXH block
Figure 1 Figure 2
block
Figure 1 Figure 2
Insertion hole
234
Series SY3000/5000/7000

Manifold Options A transparent plastic plate to put a label with the name of the function of the solenoid valve.

 If adding a name plate


If adding a name plate to a manifold in use, order a name plate bracket assembly, in addition to ordering a name plate.
Refer to the table below for the part number and the amount.

Name plate part no.


Series SS5Y3-10 SS5Y5-10/11 SS5Y7-(M)10/11 Note
Name Printed SY30M-86-N SY50M-86-N SY70M-86-N :Number of stations
plate No printing SY30M-86- SY50M-86- SY70M-86- (1 to 24)

Name plate bracket assembly part no. and number of items ordered
Series SS5Y3-10 SS5Y5-10/11
Name plate assembly part no. SY30M-85-1A SY50M-85-1A
Internal pilot
2 pcs.
Manifold SUP/EXH U/D piping
block assembly Internal pilot
2 pcs.
Pilot type
double sided piping
2 pcs. Caution
External pilot
and 1 pc. Note) 1. Be sure to shut off the power and air supplies before
U/D piping
P, E port entry mounting the name plate bracket assembly.
External pilot Furthermore, since air may remain inside the actuator,
Not required Note)
double sided piping
piping and manifold, confirm that the air is completely
Note 1) If the manifold is an external pilot, an insertion slot for name plates is on the port block of exhausted before performing any work.
the SUP/EXH block assembly. Thus, a bracket assembly is no longer required on the 2. When disassembly and assembly are performed, air
port piping side. leakage may result if the tightening of the bracket
Note 2) Name plate bracket assembly is not required for the SY7000. mounting screws is inadequate.

235
Manifold Options Series SY3000/5000/7000

Valve
Dimensions: Manifold Options/Series SY3000
Blanking plate assembly Individual SUP/EXH spacer assembly

Sub-plate
(Top/Bottom ported)

Plug-in
B A B A B A B A B A B A 3/5E

92.6

92.6
92.7
14 A 14 A 4A 4A 4A 4A
89

89
101.2

101.2
111.6

111.6
1P
12 B 12 B 2B 2B 2B 2B

3.6

14
7.2

Metal Base
13.9
One-touch fitting
(SUP port, EXH port)
One-touch fitting Applicable tube O.D.: ø4, ø5/32"
1 P
(SUP port, EXH port) : ø6, ø1/4"
Applicable tube O.D.: ø4, ø5/32"

Plug-in
62.6

63.1

: ø6, ø1/4"
2B 2 B2 B 3/5 E

4 A4 A
4A

<Type 50, 51, 52> <Type 10, 12>

C6: 92.3
N7: 96.1

Manifold Exploded View


C6: 91.8
N7: 95.6
1 P

Type 50, 51, 52


LN7: 63.8
LN7: 63.3

L6 : 61.3
L6 : 60.8
2 B2 B 3/5 E

4 A4 A

<Type 51, 52> <Type 12>

Connector Connecting Base


Individual SUP/EXH spacer assembly SUP stop valve spacer assembly
(Side ported) with residual pressure release valve

B A B A B A B A B A B A B A B A
92.6

92.6
14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A
89

89

101.2

101.2

Plug-in
12 B 12 B 12 B 12 B 12 B 12 B 12 B 12 B

LOCK LOCK

Manifold Exploded View


PUSH PUSH
(3.9)

Type 10, 11, 12


One-touch fitting One-touch fitting
(SUP port, EXH port) (SUP port, EXH port)
Applicable tube O.D.: ø2 Applicable tube O.D.: ø2
: ø3.2, ø1/8" : ø3.2, ø1/8"
: ø4, ø5/32" : ø4, ø5/32"
: ø6, ø1/4" : ø6, ø1/4"
Plug Assembly Part No.
One-touch Fittings/

1 P 1 P
1 P 1 P
77.6
78.1
77.6

78.1

2B 2 B2 B 3/5 E 2B 2 B2 B 3/5 E
39.5
39

4 A4 A 4 A4 A
4A 4A
Manifold Options

<Type 50> <Type 10>


<Type 50, 51, 52> <Type 10, 12>

236
Series SY3000/5000/7000

Dimensions: Manifold Options/Series SY3000


Double check spacer assembly with residual  Individual SUP/EXH block assembly
pressure release valve (Top ported)

B A B A B A B A B A 3/5E

92.6

92.6
14 A 14 A 14 A 14 A 4 A
89

101.2
112.8

112.8
SUP
1P
12 B 12 B 12 B 12 B 2 B

LOCK LOCK

3.6
PUSH PUSH

One-touch fitting
(SUP port, EXH port)
Applicable tube O.D.: ø4, ø5/32"
: ø6, ø1/4"

1 P 1 P
83.6

LN7: 72.3
84.1

L6 : 69.8
2B 2 B2 B 3/5 E 2 B2 B 3/5 E

4 A4 A 4 A4 A
4A

<Type 50, 51> <Type 10> <Type 12>

 Interface regulator  Individual SUP/EXH block assembly


(Side ported)

B A B A B A B A B A B A B A B A B A
(100.7)

(100.7)

92.6

14 A 14 A 14 A 14 A 14 A
92.2

14 A 14 A 14 A 14 A
92.2
92.6
89

(111.7)
103.2

103.2
(118.3)

(111.7)
109.8

109.8
(118.3)

SUP

12 B 12 B 12 B 12 B 12 B 12 B 12 B 12 B 12 B
Max. 14

Max. 14

05
SY30M- N5 --
06
SY30M- N6-- One-touch fitting
SY30M-M1-- (SUP port, EXH port)
Applicable tube O.D.: ø2
: ø3.2, ø1/8"
: ø4, ø5/32"
1 P
: ø6, ø1/4"
1 P 1 P
77.6
76.9

78.1
77.4
62.1

62.6

2B B 3/5
2 B2 B 3/5 E
48

2 B2 B2 B2 E
39.9

40.4

4 A4 A
4 A4 A4 A4 A
4A

<Type 50, 51, 52> <Type 10, 12> <Type 10>

∗The dimensions within ( ) applies to the SY30M---3.

237
Manifold Options Series SY3000/5000/7000

Valve
Dimensions: Manifold Options/Series SY5000
Blanking plate assembly Individual SUP/EXH spacer assembly

Sub-plate
(Top/Bottom ported)

Plug-in
BA BA BA BA BA BA 3/5
14 A 14 A 4A 4A 4A 4A

106.2
113.4

113.4

116.7
116.6

126.5
126.4
E
81.6

142.5
142.4
1

P
12 B 12 B 2B 2B 2B 2B

12.6

Metal Base
5.5

18.2
18.2
1 P
One-touch fitting One-touch fitting
73.2
68.6

2 B2 B (SUP port, EXH port) (SUP port, EXH port)

Plug-in
2B

3/5 E
Applicable tube O.D.: ø4 Applicable tube O.D.: ø4,
4A : ø6, ø1/4" : ø6, ø1/4"
4 A4 A
: ø8, ø5/16" : ø8, ø5/16"

<Type 50, 51, 52> <Type 10, 11, 12>

Manifold Exploded View


Type 50, 51, 52
(108.8)
(104.2)

(76.8)
(72.2)
1 P
2 B2 B

3/5 E

4 A4 A

<Type 51, 52> <Type 11, 12>

Connector Connecting Base


Individual SUP/EXH spacer assembly SUP stop valve spacer assembly
(Side ported) with residual pressure release valve

Plug-in
BA BA BA BA BA BA BA BA
14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A
106.2

106.2
113.4

113.4
127.7

127.9

Manifold Exploded View


Type 10, 11, 12
12 B 12 B 12 B 12 B 12 B 12 B 12 B 12 B

LOCK LOCK
(6.1)

PUSH PUSH

One-touch fitting One-touch fitting


(SUP port, EXH port) (SUP port, EXH port)
Applicable tube O.D.: ø4, ø5/32" Applicable tube O.D.: ø4, ø5/32"
Plug Assembly Part No.
One-touch Fittings/

: ø6, ø1/4" : ø6, ø1/4"


: ø8, ø5/16" : ø8, ø5/16"
90.7
86.1

1 P
2 B2 B
2B
3/5 E
1 P
1 P 4A
90.7
86.1

4 A4 A
1 P
Manifold Options

2 B2 B
2B
51.6

<Type 50, 51, 52> <Type 10, 11, 12>


47

3/5 E
4A
4 A4 A

<Type 50> <Type 10>

238
Series SY3000/5000/7000

Dimensions: Manifold Options/Series SY5000


Double check spacer assembly with residual  Individual SUP/EXH block  Individual SUP/EXH block
pressure release valve assembly (Top ported) assembly (Side ported)

B A B A B A B A
14 A 14 A 14 A 14 A B A 3/5 B A
106.2

4 A 14 A

113.4

113.4
113.4
138.6

138.8
E

126.7
1

12 B 12 B 12 B 12 B SUP SUP
P
2 B 12 B

LOCK LOCK
PUSH PUSH

5.7
One-touch fitting
(SUP port, EXH port) One-touch fitting
Applicable tube O.D.: ø4 (SUP port, EXH port)
: ø6, ø1/4" Applicable tube O.D.: ø4, ø5/32"
101.2

: ø8, ø5/16" : ø6, ø1/4"


96.6

1 P : ø8, ø5/16"
2 B2 B
2B

3/5 E P
4A
4 A4 A 1 1

(88.9)
1 P 1 P
<Type 50, 51> <Type 10, 11> 2 B2 B 2 B2 B

63.7
3/5 E 3/5 E

4 A4 A 4 A4 A

<Type 12> <Type 10>

 Interface regulator  Individual SUP/EXH block assembly


(Bottom ported)

BA BA BA BA BA BA
14 A 14 A 14 A 14 A 14 A 14 A B A
106.2

14 A
113.4

113.4
127.5

127.5
145.5

145.7

142.7

12 B 12 B 12 B 12 B 12 B 12 B SUP

12 B
21.7
Max. 21

Max. 21

00 One-touch fitting
SY50M- N0-
(SUP port, EXH port)
SY50M-M1- Applicable tube O.D.: ø4,
: ø6, ø1/4"
P : ø8, ø5/16"
96.2

1 P
92.4
91.6
87.8

(38.5)

2 B2 B2 B
74.5

79.1
54.6

2B
50

3/5 E
4A
4 A4 A4 A

<Type 50, 51, 52> <Type 10, 11, 12> <Type 11>

239
Manifold Options Series SY3000/5000/7000

Valve
Dimensions: Manifold Options/Series SY7000
Blanking plate assembly  Individual SUP/EXH spacer assembly

Sub-plate
(Top/Bottom ported)

Plug-in
B A B A B A B A B A B A
14 A 14 A 4A 4A 4A 4A

116.7

116.7
128.8

128.8

133.2
145.1

145.1
92.1

164.1

164.1
12 B 12 B 2B 2B 2B 2B

19.2

38.2

Metal Base
21.7
7.1
One-touch fitting One-touch fitting
(SUP port, EXH port) (SUP port, EXH port)

Plug-in
1 P
Applicable tube O.D.: ø6, ø3/8" Applicable tube O.D.: ø6, ø3/8"
80.1
78.3

2B 2 B2 B : ø8 : ø8
3/5 E : ø10 : ø10
4A
4 A4 A
: ø12 : ø12

<Type 50, 51, 52> <Type 10, 11, 12>

Manifold Exploded View


Type 50, 51, 52
(121.1)
(119.8)

(83.2)
(81.4)
1 P
2 B2 B

3/5 E
4 A4 A

Connector Connecting Base


<Type 51, 52> <Type 11, 12>

 Individual SUP/EXH spacer assembly  SUP stop valve spacer assembly with residual
(Side ported) pressure release valve

B A B A B A B A B A B A B A B A

Plug-in
14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A
116.7

116.7
(126.3)

(For ø12)

128.8
(138.2)

148.7

148.7

Manifold Exploded View


Type 10, 11, 12
(9.6)

12 B 12 B 12 B 12 B 12 B 12 B 12 B 12 B

PUSH LOCK PUSH LOCK


(For ø12)
(21.5)

One-touch fitting One-touch fitting


Plug Assembly Part No.

(SUP port, EXH port) (SUP port, EXH port)


One-touch Fittings/

Applicable tube O.D.: ø6, ø1/4" Applicable tube O.D.: ø6, ø1/4"
: ø8, ø5/16" : ø8, ø5/16"
100.9

: ø10, ø3/8" : ø10, ø3/8"


99.6

: ø12 : ø12 2B 2 B2 B
1 P

3/5 E
4 A4 A
4A
Manifold Options

1 P
100.9
99.6

1 P <Type 10> <Type 10, 11, 12>


2B 2 B2 B
56.8
55

3/5 E
4 A4 A
4A

<Type 50> <Type 10> 240


Series SY3000/5000/7000

Dimensions: Manifold Options/Series SY7000


Double check spacer assembly with residual  Individual SUP/EXH block  Individual SUP/EXH block
pressure release valve assembly (Top ported) assembly (Side ported)

B A B A B A B A B A B A
14 A 14 A 14 A 14 A 4A 14 A
116.7

(126.3)

(For ø12)
128.8

128.8

(138.2)
145.1
167.1

167.1
SUP SUP

12 B 12 B 12 B 12 B 2B 12 B

7.1
PUSH LOCK PUSH LOCK

One-touch fitting
(SUP port, EXH port)
One-touch fitting
Applicable tube O.D.: ø6, ø3/8"
: ø8 (SUP port, EXH port)
: ø10 Applicable tube O.D.: ø6, ø3/8"
: ø12 : ø8
: ø10
: ø12
113.6

114.9

P
1 P
2B 2 B2 B
1 1

(95.2)
3/5 E
4 A4 A 1 P 1 P
4A
2 B2 B 2 B2 B

68.8
3/5 E 3/5 E
4 A4 A 4 A4 A
<Type 50, 51> <Type 10, 11>

<Type 12> <Type 10>

 Interface regulator  Individual SUP/EXH block assembly


(Bottom ported)

B A
B A B A B A B A B A B A
14 A
14 A 14 A 14 A 14 A 14 A 14 A
116.7

128.8
143.8

143.8

154.9

164.1
161.8

161.8

SUP

12 B
12 B 12 B 12 B 12 B 12 B 12 B
Max. 21

Max. 21

00
SY70M- N0- P

SY70M-M1-

1 P
(42.4)

3/5 E

One-touch fitting
(SUP port, EXH port)
101.8

103.1

<Type 11> Applicable tube O.D.: ø8, ø3/8"


96.1
94.3

82.8

1 P
81

2B 2 B2 B2 B : ø10
58.3
56.5

3/5 E
: ø12
4 A4 A4 A
4A

241 <Type 50, 51, 52> <Type 10, 11, 12>


Series SY3000/5000/7000
Specific Product Precautions 1
Be sure to read before handling. Refer to back cover for Safety Instructions. For 3/4/5 Port Solenoid Valve Precautions, refer
to “Handling Precautions for SMC Products” and the Operation Manual on SMC website, http://www.smcworld.com

Environment Manual Override

Warning Warning
1. Do not use valves in atmospheres of corrosive gases, chemicals,  Push-turn locking lever type [Type E]
sea water, water, water vapor, or where there is direct contact with Push down on the manual override by finger until it stops, and
any of these. then turn it 60° clockwise. The manual override is then locked. To
2. Products compliant with IP67 enclosures (based on IEC60529) are release it, turn it counterclockwise. If it is not turned, it can be
protected against dust and water, however, these products cannot operated the same way as the non-locking type.
be used in water. If using in an environment that is exposed to
water and dust splashes, take measures such as using a
Locked
protective cover.
position
3. When using built-in silencer type manifold with an IP67 enclosure,
keep the exhaust port of the silencer from coming in direct contact
with water or other liquids.
4. The metal seal valve is provided with a hole to discharge the pilot OFF
EXH. When using in atmospheres containing water and dust,
mount it horizontally. ON
B
Valve Mounting

Caution Carefully check the manual override


Mount it so that there is no Model Thread size Tightening torque projection amount.
slippage or deformation in

(3.7)
SY3000 M2 0.12 lbf ft (0.16 N·m Max. (at OFF): 3.7 mm
gaskets, and tighten with SY5000/7000 M3 0.59 lbf ft (0.8 N·m)
the tightening torque as
shown below.

Manual Override

Warning Caution
Regardless of an electric signal for the valve, the manual override is Do not apply excessive torque when turning the manual override.
used for switching the main valve. Connected actuator is started by [0.1 N·m]
manual operation. Use the manual override after confirming that When locking the manual override, be sure to push it down before
there is no danger. turning. Turning without first pushing it down can cause damage to
 Non-locking push type the manual override and other trouble such as air leakage etc.
Push down on the manual
override button until it stops.  Slide locking type (Manual)
It is locked by sliding the manual override all the way in the
direction indicated by the arrow (ON side) with a small flat head
screwdriver or with your fingers. Slide it in the direction indicated
by the arrow (OFF side) to release it.

OFF Locked
 Push-turn locking slotted type [Type D] position
Push down on the manual override with a small flat head screw- ON
driver until it stops, and then turn it 90° clockwise. The manual
override is then locked. To release it, turn it counterclockwise. OFF
If it is not turned, it can be operated the same way as the
non-locking type. B
ON A
Locked
position

PUSH
TURN

B A

242
Series SY3000/5000/7000
Specific Product Precautions 2
Be sure to read before handling. Refer to back cover for Safety Instructions. For 3/4/5 Port Solenoid Valve Precautions, refer
to “Handling Precautions for SMC Products” and the Operation Manual on SMC website, http://www.smcworld.com

Back Pressure Check Valve Valve and Manifold Combination

Caution The SY series plug-in valve has the common configuration of the valve
3
mounting surface between base mounted type (SY 57 0) and top
3
There are two types of back pressure check valves; the one which is ported type (SY 57 3), therefore, it can be mounted to all manifolds of
built into a valve (with rubber seal type only) and the one which is the side ported type (Type 50 and Type 10), the bottom ported type
built in on the manifold side with connector connection. Both of them (Type 51 and Type 11) and the top ported type (Type 52 and Type 12).
have a check valve built-in to prevent back pressure. For this reason, For example, air output can be obtained from both sides of the A and B
use caution that the valves with external pilot specification cannot be ports of the manifold and the valve by mounting a top ported valve to a
pressurized from exhaust port [3/5(E)]. As compared with the types side ported or bottom ported manifold, and a pressure switch can be
which do not integrate the back pressure check valve, C value of the connected to the output port on one side. However, when selecting
flow-rate characteristics goes down. Please contact SMC for details. valves and manifolds, note that when a base mounted valve is
The manifold installed type back pressure check valve assembly is mounted to a top ported manifold, there will be no output from the A
assembly parts with a check valve structure. However, since slight air and B port.
leakage against the back pressure is allowed due to its structure,
adverse effects of the back pressure due to increase in exhaust
resistance cannot be prevented if the manifold exhaust port and other
exhaust ports are put together for piping or if the piping diameter is
narrowed. As a result, this may cause the actuator and air operated
equipment to malfunction. So, be careful not to restrict the exhaust
air. If the exhaust resistance becomes large, select a built-in valve
type with rubber seal.
Do not switch valves when A or B port is open to the atmosphere, or
while the actuators and air operated equipment are in operation. For
built-in valve type with rubber seal, the back pressure prevention seal
may be peeled off, which may cause air leakage or malfunctions.
Use caution especially when performing a trial operation or
maintenance work.

Exhaust Throttle

Caution
The SY series pilot valve and main valve share a common exhaust
inside the valve. Therefore, do not block the exhaust port
when arranging the piping.

Used as a 3-Port Valve

Caution
 In case of using a 5-port valve as a 3-port valve
The SY3000/5000/7000 series can be used as normally closed
(N.C.) or normally open (N.O.) 3-port port valves by closing one of
the cylinder ports 4(A) or 2(B) with a plug. However, they should be
used with the exhaust ports kept open. They are convenient at times
when a double solenoid type 3-port valve is required.

Plug position B port A port


Type of actuation N.C. N.O.
(A)4 2(B) (A)4 2(B)
Number of solenoids

Single
(EA)5 1 3(EB) (EA)5 1 3(EB)
(P) (P)

(A)4 2(B) (A)4 2(B)


Double
(EA)5 1 3(EB) (EA)5 1 3(EB)
(P) (P)

243
Series SY3000/5000/7000
Specific Product Precautions 3
Be sure to read before handling. Refer to back cover for Safety Instructions. For 3/4/5 Port Solenoid Valve Precautions, refer
to “Handling Precautions for SMC Products” and the Operation Manual on SMC website, http://www.smcworld.com

Light/Surge Voltage Suppressor

Caution
 Polar type  With power saving circuit
Positive common Negative common Power consumption is decreased by approx. 1/3 by reducing the
Single solenoid Single solenoid wattage required to hold the valve in an energized state. (Effective
energizing time is over 67 ms at 24 VDC.)
Light/surge voltage suppressor (Z) Light/surge voltage suppressor (NZ) Note) Be careful of the energizing time, as quick response and high pressure types
Polarity protection diode Polarity protection diode will become operational when the energizing time is over 40 ms.
COM COM
(+) (−) <Standard> <High pressure>
LED Electric circuit diagram
LED
Coil

Coil
(With power saving circuit) Polarity protection diode
[SOL.a] [SOL.a] (Orange) In the case of single solenoid
(−) (+)
(+) (+)

Timer circuit
Surge voltage suppressor (S) Surge voltage suppressor (NS)

Diode

Diode

PWM circuit
Coil

Coil
LED
Polarity protection diode Polarity protection diode
COM COM i2 i1
(+) (−) (−)
(−)
Coil
Coil

[SOL.a] [SOL.a] i1: Starting current, i2: Holding current


(−) (+) Polarity protection diode
Not available for the 12 VDC
Positive common Negative common specification.

Double solenoid, Double solenoid, The above circuit reduces the power consumption for holding in order to
3-position, 4-position 3-position, 4-position save energy. Refer to the electrical power waveform as shown below.
Light/surge voltage suppressor (Z) Light/surge voltage suppressor (NZ) <Electrical power waveform with power saving circuit>
[SOL.b] [SOL.b]
(−) (+) LED Applied voltage
LED
(Green)
Coil

Coil

(Green) 24 V
COM COM
(+) (−)
LED
0V
Coil

Coil

LED (Orange)
[SOL.a] (Orange) [SOL.a]
(−) (+)
Polarity protection diode Polarity protection diode

Surge voltage suppressor (S) Surge voltage suppressor (NS) Standard


0.35 (0.9) W
[SOL.b] [SOL.b] With power saving
(−) (+) circuit
0.1 (0.4) W
Coil

Coil

COM COM
(+) (−) 0W
67 ms (40 ms)
Coil

Coil

[SOL.a] [SOL.a]
(−) (+) The values in ( ) are for the high pressure and quick response types.
Polarity protection diode Polarity protection diode
• The 12 VDC specification with power saving circuit (standard
 Non-polar type specification) does not have the polarity protection diode. Do not make
With surge voltage suppressor (R) a mistake with the polarity.
Single solenoid Double solenoid • Since the voltage will drop by approx. 0.5 V due to the transistor, pay
SOL.b
attention to the allowable voltage fluctuation. (For details, refer to the
(−,+) solenoid specifications of each type of valve.)
COM
Coil

(+,−) Varistor
COM Residual voltage of the surge voltage suppressor
Coil

Varistor
(+,−)
SOL.a Note) If a varistor or diode surge voltage suppressor is used, there is
Coil

(−,+) Varistor
some residual voltage to the protection element and rated voltage.
SOL.a
(−,+) Therefore, refer to the below table and pay attention to the surge
voltage protection on the controller side. Also, since the response
With light/surge voltage suppressor (U) time does change, refer to the valve specifications on page 4.
Single solenoid Double solenoid
Residual Voltage
SOL.b LED
(−,+) Surge voltage DC
COM suppressor
Varistor 24 V 12 V
Coil

(+,−)
COM S, Z Approx. 1 V
Coil

Varistor (+,−)
SOL.a
R, U Approx. 47 V Approx. 32 V
Coil

(−,+) Varistor
LED
SOL.a
(−,+) LED 244
Series SY3000/5000/7000
Specific Product Precautions 4
Be sure to read before handling. Refer to back cover for Safety Instructions. For 3/4/5 Port Solenoid Valve Precautions, refer
to “Handling Precautions for SMC Products” and the Operation Manual on SMC website, http://www.smcworld.com

Continuous Duty Countermeasure for Surge Voltage Intrusion


 Sneak-in of surge voltage
Caution With non-polar type valves, at times of sudden interruption of the
If a valve is energized continuously for a long period of time, the rise in loading power supply, such as emergency shutdown, surge voltage
temperature due to heat-up of the coil assembly may cause a decline intrusion may be generated from loading equipment with a large
in solenoid valve performance, reduce service life, or have adverse capacity (power consumption), and the valve in a de-energized state
effects on peripheral equipment. If the valve is energized continuously may switch over (see Figure 1).
for a long period of time, be sure to use a valve with power saving When installing a breaker circuit for the loading power supply,
circuit. In particular, if three or more adjacent stations on the manifold consider using a valve with polarity (with polarity protection diode),
are energized simultaneously for extended periods of time or if the or install a surge absorption diode between the loading equipment
valves on A side and B side are energized simultaneously for a long COM line and the output equipment COM line (see Figure 2).
period of time, take special care as the temperature rise will be
greater. Output circuit

Surge voltage
24 V
sol.1: Energized
0V

R −60 V
Surge voltage
Internal circuit 24 V
0V
sol.2: De-energized
R −60 V
Surge voltage
24 V
0V
Large capacity
R load: Energized −60 V

Relay
Power supply circuit breaker

24 VDC

Figure 1. Surge intrusion circuit example (NPN outlet example) (24 VDC)

Output circuit

Surge voltage
24 V
0V
sol.1: Energized
−2 V
R
Surge voltage
24 V
Internal circuit

0V
sol.2: De-energized
−2 V
R
Surge voltage
24 V
0V
Large capacity −2 V
R load: Energized

Countermeasure
Diode parts

– (Anode) + (Cathode)

Relay
Power supply circuit breaker

24 VDC

Figure 2. Surge intrusion circuit example (NPN outlet example) (24 VDC)

245
Series SY3000/5000/7000
Specific Product Precautions 5
Be sure to read before handling. Refer to back cover for Safety Instructions. For 3/4/5 Port Solenoid Valve Precautions, refer
to “Handling Precautions for SMC Products” and the Operation Manual on SMC website, http://www.smcworld.com

Light Indication Type 1 (Connector Connecting Base)


When equipped with indicator light and surge voltage suppressor, the light Changing Connector Entry Direction
window turns orange when solenoid a is energized, and it turns green
when solenoid b is energized. Caution
Light Connector direction for electrical entry of D-sub connector <IP40>, flat
A side: Orange ribbon cable and PC wiring can be changed. If the directional change
B side: Green is required, slide the lever on the side of the connector block to the
FREE position, and then change the direction as shown in the figure.
Also, before connecting the connector, be sure to return the lever to
the LOCK position. (If the lever is difficult to slide, move the connector
a little bit to make it easier to slide the lever.)
If an excessive force is applied on the connector in the LOCK position,
Solenoid a
the connector block may be damaged. Also, using in such a way that
the connector floats in the FREE position, it may cause the lead wire
etc., to break. Thus, refrain from using in these ways.
Solenoid b

Type 5 (Metal Base) Changing Connector Entry Direction

Caution
E
Connector direction for electrical entry of D-sub connector, flat ribbon FRE
cable and PC wiring can be changed. If the directional change is LOC
K
required, push the lever on both sides to remove the connector and
change the connector direction for electrical entry as shown in the
figure. Since lead wire assemblies are attached to the connector,
excessive pulling or twisting can cause broken wires or other trouble.
Also, take precautions so that lead wires are not caught and pinched
when installing the connector.
How to Order Manifold

Caution
The letter “Í” is indicated on manifold blocks for the SY series Type 1
 (connector connecting base) as shown below. This indication refers
to the type of substrate assembly (single wiring) inside the manifold
blocks. When there is no symbol, double wiring is used.
When the manifold specification sheet does not include a wiring
specification, all stations will be double wiring specification. In this
case, single and double solenoid valves can be mounted in any
position, but when a single valve is used, there will be an unused
control signal. To avoid this, indicate positions of manifold blocks for
single wiring specification and double wiring specification on a manifold
specification sheet. (Note that double, 3-or 4-position valves cannot be
used for manifolds blocks with single wiring specification Í.)

Single wiring
marked with Í

246
Series SY3000/5000/7000
Specific Product Precautions 6
Be sure to read before handling. Refer to back cover for Safety Instructions. For 3/4/5 Port Solenoid Valve Precautions, refer
to “Handling Precautions for SMC Products” and the Operation Manual on SMC website, http://www.smcworld.com

Substrate Assemblies inside Manifolds Port Block Assembly and How to Change Piping Types between Top and Side

Caution Caution
Substrate assemblies inside of manifolds cannot be taken apart. For top ported type, the port size of A and B ports can be changed by
Attempting to do so may damage parts. switching the port block assemblies which are mounted on the body.
The piping method can also be changed by switching the top ported
type port block assembly with the side ported type cover assembly.
Also, it may cause air leakage if the mounting screws are not tightened
Fixation of DIN Rail Mounting Type Manifold securely enough when they are switched. Take care to tighten to the
correct tightening torque.
Caution Refer to page 223 for part numbers of port block assembly and body
cover assembly.
1. When the manifold is fixed with bolts on a mounting surface etc., it
When switching them while valves are mounted on a manifold, remove
can be operated just by fixing on both ends of the DIN rail if the
the clip with a flat head screwdriver before switching the port plugs and
bottom surface of the DIN rail is entirely in contact with the mounting
the One-touch fittings. It may cause air leakage if the mounting screws
surface when mounted horizontally. However, if it is used with other
are not tightened or the clip is not inserted securely enough when they
mounting or with side or reverse mounting, fix the DIN rail with bolts
are switched. Take care to tighten to the correct tightening torque.
at regular intervals. As a guide, insert bolts in 2 locations for 2-5
stations, 3 locations for 6-10 stations, 4 locations for 11-15 stations, Caution
5 locations for 16-20 stations and 6 locations for 21-24 stations.
Tightening torque Mounting screw
2. When using the manifold with DIN rail in an environment where any
M2: 0.12 lbf·ft (0.16 N·m) (SY3000)
vibration or impact is applied to it, the DIN rail itself may be broken. M3: 0.59 lbf·ft (0.8 N·m) (SY5000/7000)
In particular, if the installation surface vibrates when mounting the
Port block assembly
manifold on the wall or if a load is directly applied to the manifold, Thread piping
the DIN rail may be broken, causing the manifold to drop. When any
vibration, impact, or load is applied to the manifold, be sure to use
Mounting screw
the direct mounting manifold.

Port block assembly


One-touch fitting

∗ Part number is not shown on


Body cover assembly the body cover assembly.

 How to change while mounted on a manifold


Port block assembly
Refer to page 223.

Exchange the One-touch


fittings with the port plugs.
Clip
Tension bolt a
Refer to page 222.

Plate

Plug assembly
For SY3000
Removable by screwing
an M3 screw into the
Plug assembly center hole.
Plate Refer to page 224.
247
Series SY3000/5000/7000
Specific Product Precautions 7
Be sure to read before handling. Refer to back cover for Safety Instructions. For 3/4/5 Port Solenoid Valve Precautions, refer
to “Handling Precautions for SMC Products” and the Operation Manual on SMC website, http://www.smcworld.com

Changing One-touch Fittings Changing One-touch Fittings

Caution Caution
By replacing One-touch fittings of valve or manifold base, it is possible Bottom ported (Type 11)
to change the connection diameter of the 4(A), 2(B), 1(P), 3/5(E) ports. Secure enough space between
When replacing the One-touch fittings, remove the clip or the plate and the manifold blocks when the
the plate mounting screws with a screwdriver before pulling the plate is detached and attached.
One-touch fittings off. Mount the One-touch fittings by following the Plate part no. (10 pcs. included)
removal procedure in reverse. Plate Series Part no.
It may cause air leakage if the mounting screws are not tightened or SY5000 Note) SY50M-10-4A
the clip and the clip plate are not inserted securely enough when they SY3000/5000 SY50M-10-5A
are switched. Take care to tighten to the correct tightening torque. Mixed mounting type
Refer to page 224 for part numbers of One-touch fittings for valve or SY7000 SY70M-10-4A
manifold. Note) A and B ports (ø8 and ø5/16") of
 Valve the SY3000/5000 mixed mount-
Manifold block ing type are those for the
SY5000.
One-touch fitting
Other Tube Brands

Port plate
Caution
Caution 1. When using other than SMC brand tube, confirm that
the following specifications are satisfied with respect to
Tightening torque
the tube outside diameter tolerance.
M2: 0.12 lbf ft (0.16 N·m) 1) Nylon tube within ±0.1 mm
(SY3000) 2) Soft nylon tube within ±0.1 mm
M3: 0.59 lbf ft (0.8 N·m) 3) Polyurethane tube within +0.15 mm
(SY5000/7000) –0.2 mm
 Plug-in metal base Do not use tube which do not meet these outside diameter
tolerances. It may not be possible to connect them, or they may
Side ported (Type 50) Bottom ported (Type 51)
cause other trouble, such as air leakage or the tube pulling out after
Clip connection.
One-touch One-touch Fittings
fitting
 Tube attachment/detachment for One-touch fittings
Plate 1) Tube attachment
1. Take a tube having no flaws on its periphery and cut it off at a
Plate mounting right angle. When cutting the tube, use tube cutters TK-1, 2 or
screw 3. Do not use pinchers, nippers or scissors, etc. If cutting is
done with tools other than tube cutters, the tube may be cut
Plate assembly part no. diagonally or become flattened, etc., making a secure
Clip part no. (10 pcs. included) (10 pcs. included)
installation impossible, and causing problems such as the tube
Series Part no. Series Part no.
pulling out after installation or air leakage. Allow some extra
SY3000 SY30M-19-2A SY3000 SY30M-10-3A
length in the tube.
SY5000 SY50M-19-2A SY5000 SY50M-10-6A
2. Grasp the tube and push it in slowly, inserting it securely all the
SY7000 SY70M-19-2A SY7000 SY70M-10-7A
way into the fitting.
Note) Including mounting screw 3. After inserting the tube, pull on it lightly to confirm that it will not
 Plug-in connector connecting base come out. If it is not installed securely all the way into the
fitting, this can cause problems such as air leakage or the tube
Side ported (Type 10) Clip part no. (10 pcs. included) pulling out.
Port plate SUP/EXH block Series Part no.
2) Tube detachment
Clip SY3000 SY30M-19-1A
One-touch SY5000 Note 1) SY50M-19-6A 1. Push in the release button sufficiently, pushing its collar
fitting SY3000/5000 equally around the circumference.
SY50M-19-1A 2. Pull out the tube while holding down the release button so that
Mixed mounting type
SY7000 SV3000-70-1A it does not come out. If the release button is not pressed down
sufficiently, there will be increased bite on the tube and it will
Note 1) A and B ports (ø8 and ø5/16") of
become more difficult to pull it out.
the SY3000/5000 mixed mounting
3. When the removed tube is to be used again, cut off the portion
type are those for the SY5000.
which has been chewed before reusing it. If the chewed
Note 2) If the port plate for the SUP/EXH
block is required, please contact
portion of the tube is used as is, this can cause trouble such as
SMC.
air leakage or difficulty in removing the tube.
Manifold block
248
Series SY3000/5000/7000
Specific Product Precautions 8
Be sure to read before handling. Refer to back cover for Safety Instructions. For 3/4/5 Port Solenoid Valve Precautions, refer
to “Handling Precautions for SMC Products” and the Operation Manual on SMC website, http://www.smcworld.com

One-touch Fittings
Caution
When fittings are used, they may interfere with one another depending Fittings whose compliance with the SY series is already confirmed are
on their types and sizes. Therefore, the dimensions of the fittings to be stated below. If the fitting within the applicable range is selected, there will
used should first be confirmed in their respective catalogs. not be any interference.
Applicable Fittings: Series KQ2H, KQ2S
Port Applicable tube O.D.
Series Model Piping port Fittings
size ø2 ø3.2 ø4 ø6 ø8 ø10 ø12
KQ2H
SY330--M5 4A, 2B M5
KQ2S
KQ2H
1P, 5EA, 3EB 1/8
KQ2S
KQ2H
SY3000 X, PE M5
SS5Y3-50/51/52 (R) KQ2S
Manifold base KQ2H
1/8
KQ2S
4A, 2B
KQ2H
M5
KQ2S

Port Applicable tube O.D.


Series Model Piping port Fittings
size ø2 ø3.2 ø4 ø6 ø8 ø10 ø12
KQ2H
SY530--01 4A, 2B 1/8
KQ2S
KQ2H
1P, 5EA, 3EB 1/4
KQ2S
SY5000 KQ2H
X, PE M5
SS5Y5-50/51/52 (R) KQ2S
Manifold base KQ2H
1/4
KQ2S
4A, 2B
KQ2H
1/8
KQ2S

Port Applicable tube O.D.


Series Model Piping port Fittings
size ø2 ø3.2 ø4 ø6 ø8 ø10 ø12
KQ2H
SY730--02 4A, 2B 1/4
KQ2S
KQ2H
1P, 5EA, 3EB 3/8
KQ2S
SY7000
SS5Y7-50/51/52 (R) KQ2H
X, PE M5
Manifold base KQ2S
KQ2H
4A, 2B 1/4
KQ2S

 Trademark
DeviceNet™ is a trademark of ODVA.
EtherNet/IP™ is a trademark of ODVA.
CompoNet™ is a trademark of ODVA.
EtherCAT® is registered trademark and patented technology, licensed by Beckhoff
Automation GmbH, Germany.
249
These safety instructions are intended to prevent hazardous situations and/or
Safety Instructions equipment damage. These instructions indicate the level of potential hazard with
the labels of “Caution,” “Warning” or “Danger.” They are all important notes for
safety and must be followed in addition to International Standards (ISO/IEC)∗1),
and other safety regulations.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Caution indicates a hazard with a low level of risk ISO 4413: Hydraulic fluid power – General rules relating to systems.
Caution: which, if not avoided, could result in minor or IEC 60204-1: Safety of machinery – Electrical equipment of machines.
moderate injury.
(Part 1: General requirements)
Warning indicates a hazard with a medium level of ISO 10218-1: Manipulating industrial robots – Safety.
Warning: risk which, if not avoided, could result in death or etc.
serious injury.
Danger indicates a hazard with a high level of risk
Danger : which, if not avoided, will result in death or serious
injury.

Warning Caution
1. The compatibility of the product is the responsibility of the 1. The product is provided for use in manufacturing industries.
person who designs the equipment or decides its specifications. The product herein described is basically provided for peaceful use in
Since the product specified here is used under various operating conditions, its manufacturing industries.
compatibility with specific equipment must be decided by the person who designs If considering using the product in other industries, consult SMC beforehand and
the equipment or decides its specifications based on necessary analysis and test
exchange specifications or a contract if necessary.
results. The expected performance and safety assurance of the equipment will be
If anything is unclear, contact your nearest sales branch.
the responsibility of the person who has determined its compatibility with the
product. This person should also continuously review all specifications of the
product referring to its latest catalog information, with a view to giving due
consideration to any possibility of equipment failure when configuring the Limited warranty and Disclaimer/
equipment.
2. Only personnel with appropriate training should operate
Compliance Requirements
machinery and equipment. The product used is subject to the following “Limited warranty and Disclaimer”
The product specified here may become unsafe if handled incorrectly. The and “Compliance Requirements”.
assembly, operation and maintenance of machines or equipment including our Read and accept them before using the product.
products must be performed by an operator who is appropriately trained and
experienced. Limited warranty and Disclaimer
3. Do not service or attempt to remove product and machinery/
equipment until safety is confirmed. 1. The warranty period of the product is 1 year in service or 1.5 years after
1. The inspection and maintenance of machinery/equipment should only be the product is delivered, whichever is first.∗2)
performed after measures to prevent falling or runaway of the driven objects Also, the product may have specified durability, running distance or
have been confirmed. replacement parts. Please consult your nearest sales branch.
2. When the product is to be removed, confirm that the safety measures as
mentioned above are implemented and the power from any appropriate source 2. For any failure or damage reported within the warranty period which is clearly our
is cut, and read and understand the specific product precautions of all relevant responsibility, a replacement product or necessary parts will be provided.
products carefully. This limited warranty applies only to our product independently, and not to any
3. Before machinery/equipment is restarted, take measures to prevent other damage incurred due to the failure of the product.
unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of safety 3. Prior to using SMC products, please read and understand the warranty terms
measures if the product is to be used in any of the following and disclaimers noted in the specified catalog for the particular products.
conditions. ∗2) Vacuum pads are excluded from this 1 year warranty.
1. Conditions and environments outside of the given specifications, or use A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
Also, even within the warranty period, the wear of a product due to the use of the vacuum pad
outdoors or in a place exposed to direct sunlight.
or failure due to the deterioration of rubber material are not covered by the limited warranty.
2. Installation on equipment in conjunction with atomic energy, railways, air
navigation, space, shipping, vehicles, military, medical treatment, combustion
and recreation, or equipment in contact with food and beverages, emergency Compliance Requirements
stop circuits, clutch and brake circuits in press applications, safety equipment
or other applications unsuitable for the standard specifications described in the 1. The use of SMC products with production equipment for the manufacture of
product catalog. weapons of mass destruction (WMD) or any other weapon is strictly prohibited.
3. An application which could have negative effects on people, property, or
animals requiring special safety analysis. 2. The exports of SMC products or technology from one country to another are
4. Use in an interlock circuit, which requires the provision of double interlock for governed by the relevant security laws and regulations of the countries involved
possible failure by using a mechanical protective function, and periodical in the transaction. Prior to the shipment of a SMC product to another country,
checks to confirm proper operation. assure that all local rules governing that export are known and followed.

Revision history
Edition B ¡Added the EX260 Integrated-type (For Output) Serial ¡Changed the part numbers for A, B port mixed Edition C ¡Added the SY7000.
Transmission System. sizes for plug-in connector connecting bases ¡Added plug-in sub-plate (SY3000/5000).
¡Added EtherNet/IP™ and EtherCAT to the EX600 for Type 10 (Side ported), Type 11 (Bottom ¡Added with residual pressure release valve
Integrated-type (For Input/Output) Serial Transmission ported), Type 12 (Top ported). (SY5000).
System (Fieldbus System).
¡Deleted the mixed specification for A, B port ¡Added with safety slide locking manual override.
¡Additional Options:
· Interface regulator assembly · Dual flow fitting piping specification for plug-in connector ¡Added D-sub connector [IP67] manifold.
· Individual SUP block assembly · Name plate for manifolds connecting base for Type 12 (Top ported). ¡Added PC wiring (with power supply terminal) manifold.
· Individual EXH block assembly ¡Number of pages from 148 to 164 PY ¡Number of pages from 164 to 260 SO

Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.

250
Global Manufacturing, Distribution and Service Network
Worldwide Subsidiaries
EUROPE ASIA NORTH AMERICA
AUSTRIA LATVIA CHINA CANADA
SMC Pneumatik GmbH (Austria) SMC Pneumatics Latvia SIA SMC (China) Co., Ltd. SMC Pneumatics (Canada) Ltd.
BELGIUM LITHUANIA HONG KONG MEXICO
SMC Pneumatics N.V./S.A. SMC Pneumatics Lietuva, UAB SMC Pneumatics (Hong kong) Ltd. SMC Corporation (Mexico) S.A. DE C.V.
BULGARIA NETHERLANDS INDIA USA
SMC Industrial Automation Bulgaria EOOD SMC Pneumatics BV SMC Pneumatics (India) Pvt. Ltd. SMC Corporation of America
CROATIA NORWAY JAPAN
SMC Industrijska Automatika d.o.o. SMC Pneumatics Norway A/S SMC Corporation SOUTH AMERICA
CZECH POLAND MALAYSIA ARGENTINA
SMC Industrial Automation CZ s.r.o. SMC Industrial Automation Polska Sp.z.o.o. SMC Pneumatics (S.E.A.) Sdn. Bhd. SMC Argentina S.A.
DENMARK ROMANIA PHILIPPINES BOLIVIA
SMC Pneumatik A/S SMC Romania S.r.l. SMC Pneumatics (Philippines), Inc. SMC Pneumatics Bolivia S.R.L.
ESTONIA RUSSIA SINGAPORE BRAZIL
SMC Pneumatics Estonia SMC Pneumatik LLC. SMC Pneumatics (S.E.A.) Pte. Ltd. SMC Pneumaticos do Brazil Ltda.
FINLAND SLOVAKIA SOUTH KOREA CHILE
SMC Pneumatics Finland OY SMC Priemyselná Automatizáciá, s.r.o. SMC Pneumatics Korea Co., Ltd. SMC Pneumatics (Chile) S.A.
FRANCE SLOVENIA TAIWAN VENEZUELA
SMC Pneumatique S.A. SMC Industrijska Avtomatika d.o.o. SMC Pneumatics (Taiwan) Co., Ltd. SMC Neumatica Venezuela S.A.
GERMANY SPAIN / PORTUGAL THAILAND OCEANIA
SMC Pneumatik GmbH SMC España, S.A. SMC Thailand Ltd.
AUSTRALIA
GREECE SWEDEN SMC Pneumatics (Australia) Pty. Ltd.
SMC Hellas EPE SMC Pneumatics Sweden AB
NEW ZEALAND
HUNGARY SWITZERLAND SMC Pneumatics (N.Z.) Ltd.
SMC Hungary Ipari Automatizálási Kft. SMC Pneumatik AG
IRELAND UK
SMC Pneumatics (Ireland) Ltd. SMC Pneumatics (U.K.) Ltd.
ITALY
SMC Italia S.p.A.

U.S. & Canadian Sales Offices

WEST EAST
Austin Atlanta
Dallas Birmingham
Los Angeles Boston
Phoenix Charlotte
Portland Nashville Vancouver

San Francisco New Jersey


Montreal
Vancouver Rochester Toronto
Tampa Detroit
Boston
CENTRAL Montreal Chicago
Chicago
Cincinnati CANADA Livermore
Indianapolis
Cleveland Vancouver
Detroit Toronto
Indianapolis Windsor Atlanta

Milwaukee Montreal Sales Branches


Minneapolis Regional Distribution Centers
St. Louis Central warehouse
Austin
Toronto
Windsor

© 2014 SMC Corporation of America, All Rights Reserved.


All reasonable efforts to ensure the accuracy of the information detailed in this catalog were made at the time of publishing.
However, SMC can in no way warrant the information herein contained as specifications are subject to change without notice. SP-RRD-10M

You might also like