5-Port Solenoid Valve

Plug-in Type
Due to the flow increase,
the valve size can be reduced!
Saves energy and space
SY3000 SY5000 SY7000
10 mm 15 mm
18 mm

Ø 2, Ø 3.2,
Ø 4, Ø 6, and Ø 8∗1
fittings are connectable.
∗1 Type M10/M11 manifold

At 300 mm/s Ø 4, Ø 6, and Ø 8


fittings are connectable.
Ø 32
Existing
At 300 mm/s
Valve Ø 6, Ø 8, Ø 10, and Ø 12
size fittings are connectable.
Ø 50 DOWN Ø 50
Existing
Can drive cylinders of At 300 mm/s
∗2
up to Ø 50
(Ø 80 at 100 mm/s)
Ø 63
Valve
size
DOWN
Ø 63
Existing
Can drive cylinders of
∗2
up to Ø 63
(Ø 125 at 100 mm/s)
Ø 80
Can drive cylinders of
∗2
up to Ø 80
(Ø 160 at 100 mm/s)

Metal Base ∗2 Values based on comparison with the existing SMC model
For details, refer to page 15.

Compatible with wireless systems With pressure sensor

Connector
Connecting Base

Sub-plate

SY3000/5000/7000 Series
CAT.EUS11-103E-UK
5-Port Solenoid Valve
Plug-in Connector Connecting Base [IP67∗1]
∗1 Refer to page 39 for details on IP67.

Manifold Plug-in
Side ported Bottom ported Top ported Compatible sub-plate type

 Connector ¡IP67 enclosure for standard


specifications
type manifold Plug-in ¡The M12 waterproof connector
type ensures easy attaching/de-
taching and wiring.
¡Applicable to the side, top, and
bottom-ported types (4A and 2B
ports)

<Enlarged view
of the connector>
Connector type manifold with 32 outputs

Plug-in Metal Base [IP40]


Side ported Bottom ported Top ported

Wiring
D-sub Connector Flat Ribbon Cable Terminal Block Box Lead Wire
Circular Connector Serial Transmission
Serial Transmission Variations
Gateway-type Integrated-type (for input/output) Integrated-type (for output)

Series EX510 EX500 EX600 EX245 EX250 EX260 EX126 EX120 EX180

Applicable protocol

DeviceNetTM
PROFIBUS DP
CC-Link
EtherNet/IPTM
EtherCAT
PROFINET
CANopen
AS-Interface
OMRON CompoBus/S
CompoNetTM
Ethernet POWERLINK
IO-Link
EtherNet/IP™ compatible wireless base
PROFINET compatible wireless base
PROFIsafe
1
SY3000/5000/7000 Series
Power Saving
[Electrical power waveform Power consumption is reduced
Power Consumption with power saving circuit]
Applied voltage by the power saving circuit. Long Service Life
24 V
Power consumption is decreased to approx. 1/3 by

0.1 w
With
0V reducing the wattage required to hold the valve in an Metal seal
power saving energised state. (Effective energizing time is over 67 ms at (Service life:
circuit
200 million cycles)∗
24 VDC.) Refer to the electrical power waveform to the 1
0.4 (0.95) W With power
left.

0.35 w
saving circuit
0.1 (0.4) W ∗ Only products with an indicator light are ∗1 According to SMC life
Standard equipped with the power saving circuit. test conditions
0W ∗2 Please contact SMC if life
67 ms (40 ms) ∗ The value in ( ) is for the quick response
and high pressure types. test data is required.

Space Saving / Improved Operability


Wiring, piping, and operation are integrated on one side. A 4-position dual 3-port valve is available.
A multiple-layer type is available as an (Only for the rubber seal type)
option that saves space Piping • Two 3-port valves built into one body
in the lateral direction.
Wiring Can be operated from the top

SUP stop valve spacer


with residual pressure
release valve
Individual SUP/EXH
spacer

A side
spool valve B side
A bottom-ported type is available (A and B ports). spool valve
Space saving
By using the bottom-ported type,
it is possible to reduce the amount • 3-port valves on the A and B sides can be operated independently.
of space required for installation. • When used as a 3-port valve, only half the number of stations
is required.
• Can also be used as a 4-position, 5-port valve
• A 4-position dual 3-port valve with a back pressure check valve
is also available.
• Combination examples
Series A side B side
Installation SYA 03 0 N.C. valve N.C. valve
Panel fitting SYB 03 0 N.O. valve N.O. valve
SYC 03 0 N.C. valve N.O. valve

Overall manifold length


Different sizes (SY3000/5000 or SY5000/7000) can be mixed!
It is possible to reduce installation space, the number of serial units, and the amount of wiring. Approx. 29
%
reduction
For serial transmission SY5000 manifold SY3000 manifold Mixed manifold
EX260 SY5000: 3 stations SY3000: 4 stations SY5000: 3 stations, SY3000: 4 stations

BA BA BA B A B A B A B A B A B A B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A

Installation
space
12 B 12 B 12 B 12 B 12 B 12 B 12 B 12 B

12 B 12 B 12 B 12 B 12 B 12 B

136.7 mm 124.7 mm 186.7 mm

2 sets 1 set
Number of
serial units

2
5-Port Solenoid Valve
Improved Functionality
Back Pressure Check Valve
This prevents actuator and air operated valve malfunctions caused by the exhaust from other valves.∗1
Built-in valve type Back pressure check valve Retrofit or pre-installed type
(Check seal) If the product is affected by back pressure after
(A) (B) installation, a back pressure check
4 2 valve assembly can be added.

5 1 3
5 4 1 2 3 (EA) (P) (EB)
(EA)(A) (P) (B) (EB)

∗1 For back pressure check valve precautions,


refer to the “Specific Product Precautions” on page 315. Back pressure check
valve assembly

With residual pressure release valve (SY5000/7000) IP67 compliant


Indicator [When the 1(P) port [When the 1(P) port
For residual pressure release of When the P port is is pressurised] is not pressurised]
the 3-position closed centre valve not pressurised
EXH. EXH.
· The pressure of the 4 (A) and 2 (B) ports is
EXH. EXH.
exhausted automatically when the pressure When the P port is
pressurised
of the 1 (P) port is exhausted. 4 2 4 2
· The pressure can be visualised using the indicator (red).
· Since this valve is not a spacer type, the flow rate is 5 3 5 3
1 1
equivalent to that of the normal closed centre valve.

FREE

LOCK
Lever Type SUP Stop Valve Spacer (With residual
ual pressure release valve)
A lever has been added to
manual override button!
Solenoid valves can be
replaced individually Easy to visually check
without shutting off the
main pressure!∗1
2-action operation
Push
STEP No tools are STEP
required. Locked
Turn

Air for solenoid valves can be shut off individually! Solenoid valves can be replaced individually!
The operation of an n The
T solenoid valves canan
actuator can be be
b replaced individually
ly
checked by individually
ually without
w stopping the
shutting off the air for
or equipment
e during
the solenoid valves on maintenance.
m
the base while the <Application example>
main air is being For air operated valves,
supplied during a trial
rial such as sanitary valves,
operation. and automatic valve
control

∗1 This product is only for internal pilot specifications as the external pilot air cannot be shut off.
3
SY3000/5000/7000 Series
Improved Functionality
Slotted Type
2-position single valve
SUP Stop Valve Spacer 4(A)
(With residual pressure release valve) 2(B)

SUP stop valve


Air supply to each valve can be stopped individually. The valve and cylinder spacer assembly
can be replaced without stopping other devices and equipment.

5(EA)
1(P)
3(EB)
Button for manual release
of residual pressure 2-position single valve example
To exhaust residual pressure
on the cylinder side

Slotted Type
[Intermediate stop] [Drop prevention]
Double Check Spacer Double check spacer assembly Double check spacer assembly
(With residual pressure release valve)
Long intermediate stops and position holding are possible.

4(A) 2(B) 4(A) 2(B)


Button for manual release 5(EA) 5(EA)
of residual pressure 1(P) 1(P)
3(EB) 3(EB)
To exhaust residual pressure
on the cylinder side Exhaust centre 2-position single/double

With slide locking manual override


The ON/OFF state
ON/OFF operation and locking can be performed manually. can be checked
at a glance. ON/B side
ON
Yellow Blue OFF/A side
OFF B side A side

4
5-Port Solenoid Valve
Improved Safety
Made to Order SY7000-X13
With safety slide locking manual override
SY3000/5000/7000-X13 SY5000-X13

The double action manual override prevents accidental operation! SY3000-X13

Double-action operation
Before operation The slide locking manual overrides Operation 1 The safety slide cover is operated Operation 2 The slide locking manual
cannot be turned ON with the safety slide and moves upward. (Unlocked) overrides can be operated.
cover in place. (OFF status: Locked)
Safety slide cover Slide locking manual overrides
<OFF>

<ON>

<Vertical sliding> <Horizontal sliding>


∗ The safety slide cover cannot be locked when the slide locking manual override is turned ON.

Visual check
Red lines visible from three directions can be Safety slide covers can be checked from their raised and
checked to confirm whether the safety slide lowered positions.
cover is unlocked (FREE).
Safety slide cover

Valve state
Unlocked (raised/lowered)
Red lines

Locked

Made to Order
2-Position Single Solenoid Valve with Built-in Return Spring (Only rubber seal type)
SY3000/5000/7000-X350
The main valve returns to the OFF position when it is not
pressurized.

The main valve has a built-in spring which allows it to


return to origin (the OFF position) when the supply
pressure is stopped. This product can be used in
SRP/CS (safety-related parts of control systems)
constructions in accordance with safety standards
(ISO 13849).
Built-in return spring

5
6
5-Port Solenoid Valve

To mount the piping on top


Port block assembly
for A and B ports One-touch fitting

Thread piping
Body cover assembly

Cover assembly

Port block assembly


for P and E ports

Refer to page 24 for part numbers of the port block assembly for the
A and B ports, page 225 for part numbers of the port block assembly
for the P and E ports, and page 319 for how to change piping types.

To mount the piping on the side Mixed top-ported and side-


ported mounting is possible.
Top ported

Replace the fitting and


the port plug only.

Side ported

7
SY3000/5000/7000 Series

For SY3000 Blanking Plate with Output


 The blanking plate extracts the individual signal of the manifold valve.
Without connector With M12 connector With connector
(For the individual wiring of
the ZK2 vacuum unit)

Made to order

Application Examples
 For the control of separately mounted valves  For the control of vacuum ejectors by
Blanking plate means of Fieldbus unit signals
with output
(With M12 connector) Blanking plate with output
(With connector)
Vacuum unit
ZK2 Series

Separately
mounted valve

Valve with Pressure Sensor


 Monitoring the output pressure of the solenoid Pressure sensor
valve contributes to preventive maintenance. ¡Rated pressure range:
¡The output pressure of the 4(A) and 2(B) ports can be detected. 0 to 1 MPa
¡Detects errors such as incorrect switching, response delay, back ¡Power supply voltage:
12 to 24 VDC ±10 %
pressure interference, pressure drop, etc.
¡Output specifications:
¡Identifies faulty parts of actuators, solenoid valves, etc. Analogue output
 Space saving, Reduced installation labour 1 to 5 V (In rated pressure range)
Output impedance: Approx. 1 kΩ
¡The required amount of space and installation labour
can be reduced by directly mounting pressure
switches on the solenoid valves.

Mountable manifolds
Side ported/Type 50
Metal base
Bottom ported/Type 51
Connector Side ported/Type 10
connecting base Bottom ported/Type 11

Application Examples
 For the detection of output pressure  For the identification of faulty parts
Operation can be checked by monitoring the pressure A faulty part can quickly be identified by monitoring the operation of solenoid valves.
required to open or close air operated valves.
Solenoid valve Actuator
Air slide table
Rodless cylinder

Air gripper

8
5-Port Solenoid Valve

Only for External Pilot Vacuum Release Valve with Restrictor SY 35 AR Series
Vacuum suction and release can be controlled with a single valve!
Restrictor
PE • Flow rate adjustment of release air
Pilot EXH port • Prevents workpiece blow-off
<Manual operation>

2(B)
Vacuum pad port
X
External pilot port 1(P)
Release pressure port
3/5(E)
Vacuum pressure port

 Can be mounted on the same manifold as standard valves


∗ When an individual EXH spacer is used

 Example D side U side

(Not in use) 5(EA) 5(EA)


Release pressure port 1(P) 1(P)
Vacuum pressure port 3(EB) 3(EB)
X X
(SY3A0R) (SY3A0R) (SY3A0R) (SY3A0R) (SY3A0R)
SOL.b

SOL.b

SOL.b

SOL.b

SOL.b
SOL.a

SOL.a

SOL.a

SOL.a

SOL.a

2(B) 2(B) 2(B) 2(B) 2(B)


Vacuum pad port Vacuum pad port Vacuum pad port Vacuum pad port Vacuum pad port

Mountable manifolds
Side ported Bottom ported Top ported

Connector connecting base Type 10 Type 11 Type 12

Metal base Type 50 Type 52

∗ External pilot specification

9
SY3000/5000/7000 Series

Applicable to EX600-W Series Wireless Systems


 Noise resistance  High-speed connection  Communication response
¡Uses the 2.4 GHz ISM frequency band ¡From power supply ON to start of communication: ¡Wireless communication signal
¡Frequency hopping: Every 5 ms Min. 250 ms∗1 Response time: 5 ms
∗1 For wireless remote

 Communication cables not required  Number of I/O points  Compatible protocol


¡Reduced wiring work, space, and cost ¡Max. 1280 inputs/1280 outputs
¡Minimized disconnection risk (Max. 128 inputs/128 outputs per module)

Application Examples
For tool changing For spot welding For rotary tables
Welding environment Wired system
Communication line Power supply line

Power supply
line only

The EX260 series supports safety communication (PROFIsafe).


 This is a Fieldbus unit which supports safety standard ISO 13849-compliant safety circuit constructions.

PROFIsafe is established as an international standard (IEC 61784-3-3). It is a communication


protocol that transmits safety-related data by PROFINET communication and can be used up
until safety standards ISO 13849-1 PL e and IEC 61508/IEC 62061 SIL 3.

 Using the safety communication protocol


Refer to the EX260 Web Catalogue for details on units that support the safety communication protocol.
When using a manifold valve within an ISO 1 3 8 4 9 -compliant safety system, the device needs to be considered from both the pneumatic circuit
and the electric side.
Devices (including valves) need to be selected based on whether their functions are in line with the safety level of the equipment as a whole.
The use of valves that have been validated as being compliant with ISO 13849-2 may be required.
For details on valves that have been validated, please contact SMC.
In addition, refer to “Safety Instructions” for precautions on model selection.
10
5-Port Solenoid Valve
Variations
Wiring A, B
Common
Valve Connection specification
Series

Terminal block box (Spring type)


Serial transmission

Terminal block box

Circular connector

Negative common
Positive common
Flat ribbon cable
D-sub connector
C2

EX500 (128 points)


M12 connector

EX500 (64 points)


Lead wire
Variations
M5 1/8 1/43/8

Straight piping
EX510

EX600
EX245
EX250
EX260
EX126
EX120
EX180
5 ports
Top ported Bottom ported Side ported
Connector Connecting Base

Type
SY30
10 SY50 —— ————
From
p. 43 —
SY70

Type
SY50
Manifold

11 —— —————
From
p. 43
SY70
SY33 —
Type —
12 SY53 —— —
Plug-in

From
p. 55 — —
SY73 —
Top ported Bottom ported Side ported

SY30 —
Type
50 SY50 ————— ————————— —
From
p. 247 — —
Metal Base

SY70 —

SY30 —
Type
51 SY50 ————— ————————— —
From
p. 247 — —
SY70 —
Plug-in

SY33 —
Type

52 SY53 ————— ————————— —
From
p. 267 — —
SY73 —

SY303  —
Sub-plate


From
SY503  — — — — — —
Plug-in

p. 306 —————————— —— —
M12 connector SY703  ——
Standard  Option  Made to order (Refer to page 36.)

11
SY3000/5000/7000 Series

Valves with
Port Size Manifold Options pp. 203-218 pp. 268-278 Valve Options Function

Individual SUP block assembly


Individual EXH block assembly

With residual pressure release valve


Back pressure check valve assembly (Manifold installed type)

Silencer (One-touch fitting connection type)

Vacuum release valve with restrictor


Vacuum/Low-pressure specification
SY3000/5000 mixed mounting
SY5000/7000 mixed mounting
SUP stop valve spacer with residual pressure release valve

Oil resistant (Other than designated turbine oil)


Double check spacer with residual pressure release valve

Blanking plate with output


One-touch fittings

SUP/EXH blocking disk


Label for blocking disk
Individual SUP spacer
Individual EXH spacer

With pressure sensor


Different pressures
Interface regulator

Mixed fitting sizes


Reverse pressure
Dual flow fitting

Enclosure IP67
Blanking plate
C3 C4 C6 C8 C10 C12

Name plate
(N1) (N3) (N7) (N9) (N11)

Plug
Straight piping
Straight piping

Straight piping

Straight piping

Straight piping

Straight piping
Elbow piping∗1

Elbow piping∗1

Elbow piping∗1

Elbow piping∗1

Elbow piping∗1

——  —
———  — ∗2 ∗3 ∗4
—        —        
— External Individual External
Pilot SUP Pilot
—— — — —

— — — — ∗2 ∗3 ∗4
— — — — — —            —     
External Individual External
Pilot SUP Pilot
— — —

—  —
— — — ∗2 ∗4
— — — — —    —    —    —   —   — —
— External Individual External
Pilot SUP Pilot
— — — —

—  —
— — ∗3 ∗4
— — — — —       ————————  ———   —
— External Individual External
Pilot SUP Pilot
— —
—  —
— — ∗3
— — — — —       ————————  ———  —  — — —
— Individual
SUP
— —

—  —
— — ∗4
— — — — —    —   ————————  ———   —— —
— External Individual External
Pilot SUP Pilot
— — —

∗3
—————————————   —  ————————————  — — — —
External External
Pilot Pilot

∗1 For elbow piping, the size can only be specified in millimeters for certain port sizes. Refer to “How to Order Manifolds” for details.
∗2 Refer to the “Manifold Specifications” on page 39 for details on IP67.
∗3 Only the SY5000/7000 applies.
∗4 Only the SY3000/5000 applies.
 One-touch fittings Straight piping Elbow piping
(Upward)

12
C ON T E N T S
Optimum Actuation Size Chart of Air Cylinder ·················································································································· p. 15
Valve Specifications (Specifications, Response Time, Weight) ························································································ p. 17
Valve Construction ···························································································································································· p. 21

Manifold

Plug-in Connector p. 38
Connecting Type 10/ Type 11/ Type 12/
Base Side ported Bottom ported Top ported

Type 10/Side Ported, Type 11/Bottom Ported, Type 12/Top Ported


Plug-in Connector Connecting Base ········································································· p. 39
D-sub
connector
D-sub Connector, Flat Ribbon Cable [IP40/67] ··························································· p. 43
Flat Terminal Terminal Block Box (Spring Type) [IP67] ···································································· p. 61
ribbon cable block box

Terminal Block Box [IP67] ··························································································· p. 66


Lead wire Terminal
block box Lead Wire [IP67] ········································································································· p. 79
(Spring type)
Circular Connector [IP67] ···························································································· p. 89
Circular
connector
EX500 Gateway Decentralised System 2 (128 Points) [IP67] ·························· pp. 99, 111

EX500 EX500 Gateway Decentralised System (64 Points) [IP67] ····························· pp. 105, 113

EX600 Integrated Type (For Input/Output) Serial Transmission System (Fieldbus System) [IP67] ···· p. 115
EX600
EX245 Integrated Type (For Input/Output) Serial Transmission System [IP65] ····· p. 127
EX245
EX250 Integrated Type (For Input/Output) Serial Transmission System [IP67] ········ p. 134
EX250
EX260 Integrated Type (For Output) Serial Transmission System [IP67] ················· p. 142
EX260
EX126 Integrated Type (For Output) Serial Transmission System [IP67] ················· p. 153
EX126
EX120 Integrated Type (For Output) Serial Transmission System [IP20] ················· p. 161
EX120
EX180 Integrated Type (For Output) Serial Transmission System [IP20] ·············· p. 169
EX180
Type 10/Side Ported: Common Dimensions
(External Pilot, Silencer, Elbow Fittings, Slide Locking Manual Override) ················ p. 177

Type 11/Bottom Ported: Common Dimensions ························································· p. 180

Type 12/Top Ported: Common Dimensions ······························································ p. 182

Plug-in Manifold Mixed Mounting Type ··································································· p. 185


Mixed
mounting
Manifold Exploded View [Exploded View, Manifold Parts Nos.] ································ p. 201

How to Increase Connector Type Manifolds ····························································· p. 221

One-touch Fitting, Plug Assembly Part Nos. ····························································· p. 226

Manifold Options ······································································································· p. 227


13
Manifold

Plug-in Metal Base p. 244


Type 50/ Type 51/ Type 52/
Side ported Bottom ported Top ported

Type 50/Side Ported, Type 51/Bottom Ported, Type 52/Top Ported


Plug-in Metal Base ·································································································· p. 245
D-sub connector
D-sub Connector, Flat Ribbon Cable [IP40]
Flat ribbon cable

Type 50/Side Ported ······························································································ p. 247

Type 51/Bottom Ported ·························································································· p. 247

Type 52/Top Ported ······························································································· p. 267

Wiring Specifications ································································································· p. 272

EX510 Gateway Type Serial Transmission System [IP20]


EX510
Type 50/Side Ported ······························································································ p. 275

Type 51/Bottom Ported ·························································································· p. 275

Type 52/Top Ported ······························································································· p. 285

Manifold Exploded View [Exploded View, Manifold Parts Nos.] ································ p. 290

One-touch Fitting, Plug Assembly Part Nos. ····························································· p. 291

Manifold Options ······································································································· p. 292

Sub-plate

Plug-in Sub-plate p. 304


M12 connector

Plug-in Sub-plate Specifications (M12 Connector) ·················································· p. 305

Sub-plate Parts Nos. ································································································· p. 307

Valve Replacement Parts ··················································································································································p. 24


With Residual Pressure Release Valve ·····························································································································p. 26
Vacuum Release Valve with Restrictor ·····························································································································p. 30
Valve with Pressure Sensor ··············································································································································p. 34
Made to Order for Valves ··················································································································································p. 36
Specific Product Precautions ··········································································································································p. 314

14
Optimum Actuation Size Chart of Air Cylinder
Applicable Applicable cylinder
Main valve
cylinder Series
seal type
speed Ø6 Ø 10 Ø 16 Ø 20 Ø 25

SY3000

Rubber seal SY5000

SY7000
100 mm/s
or less
SY3000

Metal seal SY5000

SY7000

SY3000

Rubber seal SY5000

SY7000
300 mm/s
or less
SY3000

Metal seal SY5000

SY7000

SY3000

Rubber seal SY5000

SY7000
500 mm/s
or less
SY3000

Metal seal SY5000

SY7000
[Common conditions]
• Pressure: 0.5 MPa
• Piping length: 1 m
• Load ratio: 50 %
• Stroke: 200 mm
Connector type manifold (for the side and bottom-ported types)
∗ Use as a guide for selection.
Please check the actual conditions with SMC Model Selection Software.

15
Applicable cylinder

Ø 32 Ø 40 Ø 50 Ø 63 Ø 80 Ø 100 Ø 125 Ø 140 Ø 160

16
SY3000/5000/7000 Series
Valve Specifications
Valve Specifications

Valve type Rubber seal Metal seal


Fluid Air
2-position single 0.15 to 0.7
Internal pilot 2-position double 0.1 to 0.7 0.1 to 0.7 (High pressure type: 0.1 to 1)
operating pressure range
[MPa] 3-position 0.2 to 0.7
4-position dual 3-port valve 0.15 to 0.7 —
Operating pressure range –100 kPa to 0.7 (4-position: –100 kPa to 0.6) –100 kPa to 0.7 (High pressure type: –100 kPa to 1)
External pilot 2-position single
operating pressure range Pilot 2-position double 0.25 to 0.7 0.1 to 0.7 (High pressure type: 0.1 to 1)
[MPa] pressure
range 3-position
4-position dual 3-port valve Operating pressure + 0.1 or more (Min. 0.25) to 0.7 —
Ambient and fluid temperatures [°C] –10 to 50 (No freezing)
2-position single/double
SY3000 5 20∗1
4-position dual 3-port valve
SY5000
Max. operating frequency 3-position 3 10∗1
[Hz] 2-position single/double 5 10∗1
SY7000 4-position dual 3-port valve 3 —
3-position 3 10∗1
Non-locking push type
Push-turn locking slotted type
Manual override
Push-turn locking lever type
Slide locking type
Internal pilot Main/Pilot valve common exhaust Main/Pilot valve individual exhaust
Pilot exhaust type
External pilot Pilot valve individual exhaust
Lubrication Not required
Single: Unrestricted
Mounting orientation∗2 Unrestricted
Double/3-position: Main valve is horizontal.
Impact/Vibration resistance∗2 [m/s2] 150/30
Enclosure IP67 (Based on IEC60529)∗3
Coil rated voltage [DC] 24, 12 V
Allowable voltage fluctuation [V] ±10 % of rated voltage∗4
Standard 0.35 (With indicator light: 0.4)
High pressure type, Quick response type 0.9 (With indicator light: 0.95)
Power consumption [W]
Standard: 0.1∗5 (With indicator light only) [Inrush 0.4, Holding 0.1],
With power saving circuit
High pressure type: 0.4∗5 (With indicator light only) [Inrush 0.95, Holding 0.4]
Surge voltage suppressor Diode (Varistor for non-polar type)
Indicator light LED
∗1 Use below 5 Hz for with the power saving circuit.
∗2 Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right angles to the main valve and armature in both
energised and de-energised states every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. The test was performed at both energised and de-energised
states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period)
Refer to page 319 for the fixation of DIN rail mounting type manifold.
∗3 In the case of a metal seal, there are restrictions in the operating environment. Refer to the “Specific Product Precautions” on page 314.
∗4 Due to voltage drops by the internal circuit in S/Z type and T type (with power saving circuit), use within the allowable voltage fluctuation as follows.
24 VDC: –7 % to +10 % 24 VDC: –8 % to +10 %
S/Z type T type
12 VDC: –4 % to +10 % 12 VDC: –6 % to +10 %
∗5 For details, refer to page 316.

17
Valve Specifications SY3000/5000/7000 Series

Response Time

Response time [ms] (at 0.5 MPa)∗1


Standard Quick response type
Series Seal type Model Type of actuation Without light/ With light/surge Without light/ With light/surge
surge voltage voltage suppressor surge voltage voltage suppressor
suppressor S/Z type R/U type suppressor S/Z type R/U type
Rubber seal SY310 15 or less 20 or less 15 or less 12 or less 15 or less 12 or less
2-position single
Metal seal SY311 15 or less 20 or less 15 or less 12 or less 15 or less 12 or less
Rubber seal SY320 12 or less 15 or less 12 or less 10 or less 13 or less 10 or less
2-position double
SY3000 Metal seal SY321 12 or less 15 or less 12 or less 10 or less 13 or less 10 or less
Rubber seal SY33/4/50 18 or less 22 or less 18 or less 14 or less 18 or less 14 or less
3-position
Metal seal SY33/4/51 18 or less 22 or less 18 or less 14 or less 18 or less 14 or less
Rubber seal SY3A/B/C0 4-position dual 3-port valve 18 or less 22 or less 18 or less 15 or less 19 or less 15 or less
Rubber seal SY510 24 or less 31 or less 24 or less 18 or less 25 or less 18 or less
2-position single
Metal seal SY511 24 or less 31 or less 24 or less 18 or less 25 or less 18 or less
Rubber seal SY520 12 or less 15 or less 12 or less 10 or less 13 or less 10 or less
2-position double
SY5000 Metal seal SY521 12 or less 15 or less 12 or less 10 or less 13 or less 10 or less
Rubber seal SY53/4/50 30 or less 34 or less 30 or less 24 or less 28 or less 24 or less
3-position
Metal seal SY53/4/51 28 or less 30 or less 28 or less 23 or less 25 or less 23 or less
Rubber seal SY5A/B/C0 4-position dual 3-port valve 35 or less 42 or less 35 or less 28 or less 35 or less 28 or less
Rubber seal SY710 47 or less 58 or less 53 or less 42 or less 52 or less 44 or less
2-position single
Metal seal SY711 39 or less 48 or less 39 or less 34 or less 43 or less 34 or less
Rubber seal SY720 18 or less 19 or less 19 or less 18 or less 17 or less 17 or less
2-position double
SY7000 Metal seal SY721 17 or less 17 or less 16 or less 16 or less 16 or less 16 or less
Rubber seal SY73/4/50 52 or less 54 or less 47 or less 42 or less 46 or less 40 or less
3-position
Metal seal SY73/4/51 38 or less 45 or less 39 or less 33 or less 38 or less 34 or less
Rubber seal SY7A/B/C0 4-position dual 3-port valve 52 or less 60 or less 54 or less 49 or less 53 or less 48 or less
∗1 Based on dynamic performance test, JIS B 8419-2010 (Coil temperature: 20 °C, at rated voltage)
Since the response time of the external pilot type of the 4-position dual 3-port valve differs from the above table, please contact SMC.

18
SY3000/5000/7000 Series

Valve Weight
SY3000 series
Valve model Seal type Type of actuation Weight [g] Valve model Seal type Type of actuation Weight [g]
Single 74 Single 76
2-position 2-position
Double 83 Double 86
Closed centre SY301 Metal seal Closed centre
SY300 Rubber seal
3-position Exhaust centre 87 3-position Exhaust centre 90
Pressure centre Pressure centre
4-position Dual 3-port valve 83

Seal Port size Weight Seal Port size Weight


Valve model Type of actuation Valve model Type of actuation
type 4, 2 (A, B) [g] type 4, 2 (A, B) [g]
Single 74 Single 76
2-position 2-position
Double 83 Double 86
Closed centre SY331-M5 Closed centre M5 x 0.8
SY330-M5 3-position Exhaust centre
M5 x 0.8
87 3-position Exhaust centre 90
Pressure centre Pressure centre
4-position Dual 3-port valve 83 Single 84
2-position
Single 82 Double C2 94
2-position
Double
C2
91 SY331-C2 Closed centre Ø 2 One-touch
Closed centre 3-position Exhaust centre fitting 98
SY330-C2 3-position Exhaust centre
Ø 2 One-touch
95 Pressure centre
fitting
Pressure centre Single 87
2-position
4-position Dual 3-port valve 91 Double C3 97
Metal
2-position
Single 85 SY331-C3 seal Closed centre Ø 3.2 One-touch
Double 94 3-position Exhaust centre fitting 101
C3
Rubber Closed centre Pressure centre
SY330-C3 seal 3-position Exhaust centre
Ø 3.2 One-touch
98 Single 79
fitting 2-position
Pressure centre Double C4 89
4-position Dual 3-port valve 94 SY331-C4 Closed centre Ø 4 One-touch
Single 77 3-position Exhaust centre fitting 93
2-position
Double 86 Pressure centre
C4
Closed centre Single 82
SY330-C4 3-position Exhaust centre
Ø 4 One-touch
90
2-position
Double C6 92
fitting
Pressure centre SY331-C6 Closed centre Ø 6 One-touch
4-position Dual 3-port valve 86 3-position Exhaust centre fitting 96
Single 80 Pressure centre
2-position
Double 89
C6
Closed centre
SY330-C6 3-position Exhaust centre
Ø 6 One-touch
93
fitting
Pressure centre
4-position Dual 3-port valve 89

SY5000 series
Valve model Seal type Type of actuation Weight [g] Valve model Seal type Type of actuation Weight [g]
Single 82 Single 91
2-position 2-position
Double 90 Double 101
Closed centre SY501 Metal seal Closed centre
SY500 Rubber seal
3-position Exhaust centre 100 3-position Exhaust centre 111
Pressure centre Pressure centre
4-position Dual 3-port valve 90

Seal Port size Weight Seal Port size Weight


Valve model Type of actuation [g]
Valve model Type of actuation [g]
type 4, 2 (A, B) type 4, 2 (A, B)
Single 102 Single 111
2-position 2-position
Double 110 Double 121
Closed centre SY531-01 Closed centre 1/8
SY530-01 3-position Exhaust centre
1/8
120 3-position Exhaust centre 131
Pressure centre Pressure centre
4-position Dual 3-port valve 110 Single 124
2-position
Single 115 Double C4 134
2-position
Double
C4
123 SY531-C4 Closed centre Ø 4 One-touch
Closed centre 3-position Exhaust centre fitting 144
SY530-C4 3-position Exhaust centre
Ø 4 One-touch
133 Metal Pressure centre
fitting
Pressure centre seal Single 120
2-position
Rubber 4-position Dual 3-port valve 123 Double C6 130
seal
2-position
Single 110 SY531-C6 Closed centre Ø 6 One-touch
Double 118 3-position Exhaust centre fitting 140
C6
Closed centre Pressure centre
SY530-C6 3-position Exhaust centre
Ø 6 One-touch
128 Single 108
fitting 2-position
Pressure centre Double C8 118
4-position Dual 3-port valve 118 SY531-C8 Closed centre Ø 8 One-touch
Single 99 3-position Exhaust centre fitting 128
2-position
Double 107 Pressure centre
C8
Closed centre
SY530-C8 3-position Exhaust centre
Ø 8 One-touch
117
fitting
Pressure centre
4-position Dual 3-port valve 107

19
Valve Specifications SY3000/5000/7000 Series

Valve Weight
SY7000 series
Valve model Seal type Type of actuation Weight [g] Valve model Seal type Type of actuation Weight [g]
Single 110 Single 122
2-position 2-position
Double 118 Double 133
Closed centre SY701 Metal seal Closed centre
SY700 Rubber seal
3-position Exhaust centre 133 3-position Exhaust centre 150
Pressure centre Pressure centre
4-position Dual 3-port valve 114

Seal Port size Weight Seal Port size Weight


Valve model Type of actuation Valve model Type of actuation
type 4, 2 (A, B) [g] type 4, 2 (A, B) [g]
Single 125 Single 136
2-position 2-position
Double 133 Double 148
Closed centre SY731-02 Closed centre 1/4
SY730-02 3-position Exhaust centre
1/4
147 3-position Exhaust centre 164
Pressure centre Pressure centre
4-position Dual 3-port valve 129 Single 174
2-position
Single 163 Double C6 186
2-position
Double
C6
171 SY731-C6 Closed centre Ø 6 One-touch
Closed centre 3-position Exhaust centre fitting 202
SY730-C6 3-position Exhaust centre
Ø 6 One-touch
186 Pressure centre
fitting
Pressure centre Single 162
2-position
4-position Dual 3-port valve 167 Double C8 174
Metal
2-position
Single 151 SY731-C8 seal
Closed centre Ø 8 One-touch
Double 159 3-position Exhaust centre fitting 190
C8
Rubber Closed centre Pressure centre
SY730-C8 seal 3-position Exhaust centre
Ø 8 One-touch
174 Single 148
fitting 2-position
Pressure centre Double C10 159
4-position Dual 3-port valve 155 SY731-C10 Closed centre Ø 10 One-touch
Single 136 3-position Exhaust centre fitting 176
2-position
Double 144 Pressure centre
C10
Closed centre Single 157
SY730-C10 3-position Exhaust centre
Ø 10 One-touch
159
2-position
Double C12 169
fitting
Pressure centre SY731-C12 Closed centre Ø 12 One-touch
4-position Dual 3-port valve 140 3-position Exhaust centre fitting 185
Single 146 Pressure centre
2-position
Double 154
C12
Closed centre
SY730-C12 3-position Exhaust centre
Ø 12 One-touch
169
fitting
Pressure centre
4-position Dual 3-port valve 150

20
SY3000/5000/7000 Series
Valve Construction
Rubber Seal
2-position single Top ported
(A) (B)
4 2

t e q w r t e q w r

2-position single
5 4 1 2 3 5 1 3 (A)4 2(B)
(EA) (A) (P) (B) (EB) (EA) (P) (EB)

(EA)5 1 3(EB)
(P)

2-position double
t e q w r

2-position double
5 4 1 2 3 (A)4 2(B)
(EA) (A) (P) (B) (EB)

(EA)5 1 3(EB)
(P)

3-position closed centre/exhaust centre/pressure centre


t e q w r 3-position closed centre 3-position exhaust centre
(A)4 2(B) (A)4 2(B)

(EA)5 1 3(EB) (EA)5 1 3(EB)


(P) (P)

3-position pressure centre


(A)4 2(B)
5 4 1 2 3
(EA) (A) (P) (B) (EB)

(EA)5 1 3(EB)
(P)

Component Parts
No. Description Material Note
SY3000: Zinc die-casted
1 Body
SY5000/SY7000: Aluminium die-casted
Special resin/HNBR
2 Spool valve
(3-position valve:
Aluminium/HNBR )
3 Piston Resin
Body cover assembly Resin For the side/bottom-ported type
SY3000: Resin
4 SY5000: Zinc die-casted (Thread piping)
Port block assembly For the top-ported type
SY5000: Resin (Fitting)
SY7000: Aluminium die-casted
5 Pilot valve assembly — Refer to page 25.

21
Valve Construction SY3000/5000/7000 Series

Rubber Seal
4-position dual 3-port valve
4-position dual 3-port valve
N.C. valve x 2 pcs. N.O. valve x 2 pcs.
t e q w r 4(A) 2(B) 4(A) 2(B)

5(EA) 1(P) 3(EB) 5(EA) 1(P) 3(EB)


N.C. valve, N.O. valve 1 pc. of each
5 4 1 2 3
(EA) (A) (P) (B) (EB) 4(A) 2(B)

5(EA) 1(P) 3(EB)

2-position double with back pressure check valve (Built-in valve type)

t e q w r
2-position double
with back pressure check valve
(A)4 2(B)

(EA)5 1 3(EB)
(P)
5 4 1 2 3
(EA) (A) (P) (B) (EB)
∗ The built-in valve type back pressure check valve is not available for the SY7000.

4-position dual 3-port valve with back pressure check valve (Built-in valve type)

4-position dual 3-port valve with back pressure check valve


t e q w r
N.C. valve x 2 pcs. N.O. valve x 2 pcs.
4(A) 2(B) 4(A) 2(B)

5(EA) 1(P) 3(EB) 5(EA) 1(P) 3(EB)


5 4 1 2 3 N.C. valve, N.O. valve 1 pc. of each
(EA) (A) (P) (B) (EB)
4(A) 2(B)

5(EA) 1(P) 3(EB)

∗ The built-in valve type back pressure check valve is not available for the SY7000.

22
SY3000/5000/7000 Series

Metal Seal
2-position single Top ported
(A) (B)
4 2

t e q w r t e q w r

2-position single
5 4 1 2 3 5 1 3 (A)4 2(B)
(EA) (A) (P) (B) (EB) (EA) (P) (EB)

(EA)5 1 3(EB)
(P)

2-position double
t e q w r

2-position double
5 4 1 2 3 (A)4 2(B)
(EA) (A) (P) (B) (EB)

(EA)5 1 3(EB)
(P)

3-position closed centre/exhaust centre/pressure centre


t e q w r

3-position closed centre 3-position exhaust centre


(A)4 2(B) (A)4 2(B)

(EA)5 1 3(EB) (EA)5 1 3(EB)


(P) (P)
5 4 1 2 3
(EA) (A) (P) (B) (EB) 3-position pressure centre
(A)4 2(B)

(EA)5 1 3(EB)
(P)

Component Parts
No. Description Material Note
SY3000: Zinc die-casted
1 Body
SY5000/7000: Aluminium die-casted
2 Spool, Sleeve Stainless steel/HNBR
3 Piston Resin
Body cover assembly Resin For the side/bottom-ported type
SY3000: Resin
4 SY5000: Zinc die-casted (Thread piping)
Port block assembly For the top-ported type
SY5000: Resin (Fitting)
SY7000: Aluminium die-casted
5 Pilot valve assembly — Refer to page 25.

23
SY3000/5000/7000 Series
Valve Replacement Parts
How to Order Port Block Assembly
Mounting screw

SY 0V 6A One-touch fitting

Series Thread type


3 3000 — Rc
5 5000 F G
7 7000 N NPT
T NPTF
Pilot type ∗ Except M5
— Internal pilot
A, B port size
R External pilot Thread piping
Symbol Port size Applicable series
Option for mounting M5 M5 x 0.8 SY3000
— Standard (Valve mounting screw without drop prevention) 01 1/8 SY5000
1 Drop prevention type valve mounting screw 02 1/4 SY7000
Metric size (One-touch fitting)
Applicable series
Symbol Port size
SY3000 SY5000 SY7000
C2 Ø2  — —
C3 Ø 3.2  — —
C4 Ø4   —
C6 Ø6   
C8 Ø8 —  
C10 Ø 10 — — 
C12 Ø 12 — — 
Inch size (One-touch fitting)
Applicable series
Symbol Port size
SY3000 SY5000 SY7000
N1 Ø 1/8"  — —
N3 Ø 5/32"   —
N7 Ø 1/4"   
N9 Ø 5/16" —  
N11 Ø 3/8" — — 

 Possible to replace only the One-touch fitting


Port size SY3000 SY5000 SY7000
Ø2 VVQ1000-50A-C2 — —
Ø 3.2 VVQ1000-50A-C3 — —
Ø4 VVQ1000-50A-C4 VVQ1000-51A-C4 —
Metric size Ø6 VVQ1000-50A-C6 VVQ1000-51A-C6 VVQ2000-51A-C6
Ø8 — VVQ1000-51A-C8 VVQ2000-51A-C8
Ø 10 — — VVQ2000-51A-C10
Ø 12 — — KQ2H12-17-X224
Ø 1/8" VVQ1000-50A-N1 — —
Ø 5/32" VVQ1000-50A-N3 VVQ1000-51A-N3 —
Inch size Ø 1/4" VVQ1000-50A-N7 VVQ1000-51A-N7 VVQ2000-51A-N7
Ø 5/16" — VVQ1000-51A-N9 VVQ2000-51A-N9
Ø 3/8" — — VVQ2000-51A-N11

Refer to pages 319 and 320 for how to replace


the port block assembly, One-touch fitting, and
body cover assembly.

24
SY3000/5000/7000 Series

Body Cover Assembly


∗ Used when the top-ported type is changed to the side or bottom-ported type

Mounting screw

Part no.
Series Standard (Valve mounting Drop prevention type
screw without drop prevention) valve mounting screw
Internal pilot SY30V-16A SY30V-16A-1
SY3000
External pilot SY30V-16AR SY30V-16AR-1
Internal pilot SY50V-16A SY50V-16A-1
SY5000
External pilot SY50V-16AR SY50V-16AR-1
Internal pilot SY70V-16A SY70V-16A-1
SY7000
External pilot SY70V-16AR SY70V-16AR-1
∗ The part number is not indicated on the product.

How to Order Pilot Valve Assembly (With a gasket and two mounting screws)

V112 A How to replace pilot valves

Pilot valve option Pilot cover assembly Pilot valve assembly


— Standard (0.7 MPa) Series Part no.
B Quick response type (0.7 MPa) SY3000 SY30V-25A
SY5000 Gasket
K High pressure type (1.0 MPa)∗1 SY50V-25A
SY7000
∗1 Only the metal seal type is available ∗ Pilot cover x 1 + B tight flat
a-side pilot valve
for the high pressure type. (1.0 MPa) head screw x 1

Coil type
w
— Standard Pilot cover
T With power saving circuit
Socket
Rated voltage q w
5 24 VDC
b-side pilot valve
6 12 VDC
B tight flat head screw (M1.7)
Tightening torque: 0.12 N·m Pilot valve mounting screw (M2 x 16.5)
Caution Tightening torque: 0.15 N·m
1. The coil specification and voltage (including
light/surge voltage suppressor) cannot be
changed by changing the pilot valve Pilot valve mounting screw (M2 x 25)
assembly. Tightening torque: 0.15 N·m
2. When selecting the coil type with power
saving circuit, it is not possible to change to • Loosen B tight flat head screw to remove the pilot cover in the direction
high pressure/power saving circuit type.
indicated by the arrow q.
• Remove the pilot valve mounting screws.
• Remove the pilot valve in the direction indicated by the arrow w.
∗ Assemble by following the removal procedure in reverse.
∗ Ensure the gasket is mounted, and take care not to bend the socket.
∗ Be noted for mounting that there are two types of lengths for the pilot valve mounting
screws.

25
SY5000/7000 Series RoHS

With Residual Pressure Release Valve


Mountable manifold
SS5Y5/7-50/51 type manifold
SS5Y5/7-(M)10/11 type manifold
Sub-plate single unit (Except top-ported type) How to Order (With mounting screw)

SY 5 3 0 0 5 1 E
Series q w e r t y Thread type
5 SY5000
7 SY7000 Base mounted Port size
(The top-ported type is not available.)
Type of actuation Port location
3 3-position closed centre∗1 With residual pressure release valve
E With residual pressure release valve∗1
∗1 Only the closed centre type is available.
∗1 Mounting screw types, hexagon socket head cap screw Wiring specification
B and drop prevention type K, H are not available. With sub-plate
∗ Make selections for items
Protective class 15 to 18 on page 306.
class # (Mark: ) With sub-plate

q Seal type r Rated voltage y Manual override


0 Rubber seal 5 24 VDC —: D:
1 Metal seal 6 12 VDC Non-locking Push-turn
∗ The applicable rated voltage varies depending push type locking slotted

w Pilot valve option on the manifold wiring type. Refer to the “How type
to Order Manifolds” pages.
— Standard (0.7 MPa)
B
K∗1
Quick response type (0.7 MPa)
High pressure type (1.0 MPa)
t Light/surge voltage suppressor
and common specification E: F:
∗1 Only the metal seal type is available for the Push-turn Slide locking
high pressure type. Surge voltage Common locking lever type
Symbol With light
suppressor specification
e Coil type — — —
type

— Standard R — Non-polar
T With power saving circuit (Continuous duty type) U 
∗ Be sure to select the power saving circuit type S — Positive ∗ Refer to page 36 for the safety slide locking

if the valve is to be continuously energised for Z  common manual override.
long periods of time. NS — Negative ∗ When ordering a valve individually, the
∗ Be careful of the energising time when the
NZ  common base gasket is not included.
power saving circuit is selected. Refer to page
∗ For the non-polar type, be careful of surge Since the base gasket is attached to the
316 for details.
voltage intrusion. Refer to page 317 for details. manifold, please order the base gasket
∗ Only “Z” and “NZ” types are available with a separately if it is needed for maintenance.
power saving circuit. Refer to page 222 or 290 for base gasket part
numbers.
Refer to Table 1 for mounting screw part
numbers.

Table 1. Valve mounting screw


SY5000 SY7000
SY5000-221-2A SY7000-221-10A
(2 pcs.) (3 pcs.)

Valve Specifications Symbol


<When the 1(P) port <When the 1(P) port
is exhausted> is pressurised>
Rubber seal Metal seal
Valve construction
3-position closed centre valve with residual pressure release valve∗1 EXH. EXH.
Fluid Air EXH. EXH.
Operating pressure range [MPa]∗2 0.3 to 0.7 0.3 to 0.7 (High pressure: 0.3 to 1)
4 2 4 2
SY5000 117 128
Weight [g]
SY7000 156 177
5 3 5 3
∗1 Rubber seal is used for the residual pressure release valve. 1 1
∗2 Internal pilot type only A mechanism is used that exhausts the pressure of the
∗ Other specifications are common to the valve specifications on page 17. cylinder port when the P port supply pressure of the
∗ When using in combination with an individual SUP/EXH spacer or an interface regulator, the 3-position closed centre valve is exhausted.
length of the required mounting screws will differ. Please contact SMC for details.

26
SY3000/5000/7000 Series

Dimensions
SY5000

A side indicator (Red)∗1


Exhausted: Concave
EXH port Pressurised: End face
1.3 15
EXH port

B side indicator (Red)∗1

47.6
45.1
(For E type: 60.2)
62.3 (For F type)

Exhausted: Concave

30.1
Pressurised: End face
56.6

(Light/surge voltage suppressor)


116.6
Manual override 84.5
SY7000
12.6
39.8 30.7
( Push-turn locking slotted
type: Press, then rotate it. )
4(A) port side : Blue
2(B) port side : Yellow
Manual override part 2 x Ø 3.2
(For manifold mounting)

A side indicator (Red)∗1


EXH port 18 2.2 Exhausted: Concave
Pressurised: End face
12 14
EXH port

B A
B side indicator (Red)∗1
51.3
(For E type: 60.2)
62.3 (For F type)

45.5

Exhausted: Concave
33.3

Pressurised: End face


56.6

Manual override 133.2


Push-turn locking slotted
( type: Press, then rotate it. ) 47
101.1
37.1
4(A) port side : Blue (For rubber seal)
: Grey (For metal seal) 28.4
2(B) port side : Yellow
16.8
BA

(Light/surge voltage suppressor)


3 x Ø 3.2
Manual override part (For manifold mounting)

∗1 The indicator shows the pressurization status.


Do not push it.

27
SY3000/5000 Series RoHS
Only for
External Pilot Vacuum Release Valve with Restrictor
Mountable manifold [External pilot]
SS5Y3/5-50/52 type manifold
SS5Y3/5-(M)10/11/12 type manifold
Sub-plate single unit (Except SS5Y3-11 type) How to Order (With mounting screw)

Thread type
Port size
Side ported/
Bottom ported SY 3 A 0 R 5 1
Top ported SY 3 A 3 R 5 1 C6
Port location
q w e r t y u i Wiring specification
With sub-plate
∗ Make selections for items 15 to 18 on page 306.

With sub-plate

q Series w Pilot type r Rated voltage y Manual override


3 SY3000 R External pilot 5 24 VDC —: D:
5 SY5000 6 12 VDC Non-locking Push-turn
push type locking
slotted
e Coil type t Light/surge voltage suppressor type
— Standard and common specification
With power saving circuit Surge voltage Common
T (Continuous duty type)
Symbol With light
E: F:
suppressor specification
∗ Be sure to select the power — — — Push-turn Slide locking
saving circuit type if the valve is R — Non-polar locking type
to be continuously energised U  lever
for long periods of time. type
S —
∗ Be careful of the energising  Positive common
Z 
time when the power saving NS — Negative
circuit is selected. ∗ Refer to page 36 for the safety slide locking
NZ  common
Refer to page 316 for details. manual override.
∗ For the non-polar type, be careful of surge voltage intru-
sion. Refer to page 317 for details.
Protective class ∗ Only “Z” and “NZ” types are available with a power saving
class # (Mark: ) circuit.

How to Order Manifold Assembly u B port size


One-touch fitting (Metric size)
Symbol B port SY3000 SY5000
Example (SS5Y3-10F1-R) C4 Ø 4 One-touch fitting  
3-position 3-port valve with restrictor (24 VDC) C6 Ø 6 One-touch fitting  
SY3A0R-5U1 C8 Ø 8 One-touch fitting — 
One-touch fitting (Inch size)
Symbol B port SY3000 SY5000
N3 Ø 5/32" One-touch fitting  
N7 Ø 1/4" One-touch fitting  
N9 Ø 5/16" One-touch fitting — 
∗ When selecting the port size for each station, specify on a manifold
ide specification sheet separately.
Us
tion
s ∗ When mounting on the manifold base or sub-plate, the A port is plugged.
Sta When a manifold base or sub-plate is ordered separately, mount a plug
3
Manifold base (5 stations) 2 on the A port.
1
SS5Y3-10F1-05DR-C6 e
sid
i Type of mounting screw
D

SS5Y3-10F1-05DR-C6···1 set (Type 10 5-station manifold base part no.) — Round head combination screw
∗SY3A0R-5U1 (3-position 3-port with restrictor part no.)····5 sets B Hexagon socket head cap screw
The asterisk denotes the symbol for the assembly. ∗ When ordering a valve individually, the base gasket is not included.
Prefix it to the part numbers of the valve, etc. Since the base gasket is attached to the manifold, please order the
base gasket separately if it is needed for maintenance.
• For the valve arrangement, the valve closest to the D side is considered the 1st station. Refer to page 222 or 290 for base gasket and mounting screw part
• Under the manifold part number, state the valves to be mounted in order starting
numbers.
with the 1st station as shown in the figure above. If the arrangement becomes
∗ “B” and “H” cannot be selected for the individual SUP/EXH spacer
too complicated, specify the details on a manifold specification sheet.
assembly or interface regulator.

28
SY3000/5000 Series

Valve Specifications
Valve construction 3-position 3-port valve with restrictor
Seal Rubber seal
Fluid Air
Type of actuation Normally closed
Release pressure port 1(P) 0 to 0.6
Operating pressure
Vacuum pressure port 3(EB), 3/5(E) -100 kPa to 0.7∗1
range [MPa]
Pilot X port Release pressure + 0.1 or more (Min. 0.25) to 0.7
Restrictor operation Manual
∗1 Can be used with positive pressure to suit the application
∗ Other specifications are common to the valve specifications on page 17.
∗ Quick response type is not available.

Weight
Valve model Weight [g]
SY3A0R 90
Port size
Valve model Weight [g]
2(B) port
C4 91
SY3A3R
C6 93
Valve model Weight [g]
SY5A0R 94
Port size
Valve model Weight [g]
2(B) port
Symbol
C4 118
2(B)
Vacuum pad port SY5A3R C6 115
C8 121

SOL.a SOL.b Response Time

Without light/surge With light/surge voltage suppressor


Valve model
1(P) 3(EB) X
voltage suppressor S/Z type R/U type
Release pressure Vacuum pressure SY3AR 18 26 18
port port SY5AR 27 32 27
∗ P = 0.1 MPa X = 0.5 MPa

Manifold Flow Rate Characteristics∗1

Flow Rate Characteristics (When restrictor is fully open)


q Plug-in Metal Base
Port size Valve flow rate characteristics
Manifold type 1, 3 2 1→2 (P→B) 2→3 (B→EB)
(P, EB) (B) C [dm3/(s·bar)] b Q [l/min (ANR)]∗2 C [dm3/(s·bar)] b Q [l/min (ANR)]∗2
SS5Y3-50R (Side ported) 1/8 C6 0.7 0.24 172 1.0 0.16 234
SS5Y3-52R (Top ported) 1/8 C6 1.0 0.25 247 1.1 0.25 271
SS5Y5-50R (Side ported) 1/4 C8 1.0 0.30 254 2.3 0.10 522
SS5Y5-52R (Top ported) 1/4 C8 1.4 0.16 328 2.4 0.14 556

w Plug-in Connector Connecting Base


Port size Valve flow rate characteristics
Manifold type 1, 3 2 1→2 (P→B) 2→3 (B→EB)
(P, EB) (B) C [dm3/(s·bar)] b Q [l/min (ANR)]∗2 C [dm3/(s·bar)] b Q [l/min (ANR)]∗2
SS5Y3-10R (Side ported) C8 C6 0.7 0.36 145 1.2 0.22 291
SS5Y3-12R (Top ported) C8 C6 1.0 0.26 248 1.2 0.20 287
SS5Y5-10R (Side ported) C10 C8 1.0 0.20 240 2.9 0.17 683
SS5Y5-11R (Bottom ported) C10 C8 1.0 0.30 354 3.3 0.24 809
SS5Y5-12R (Top ported) C10 C8 1.4 0.15 326 2.6 0.24 637
∗1 The value is for manifold base with 5 stations.
∗ Calculation of effective area S and sonic conductance C: S = 5.0 x C
∗2 These values have been calculated according to ISO 6358 and indicate the fl ow rate under standard conditions with an inlet pressure of 0.6 MPa
(relative pressure) and a pressure drop of 0.1 MPa.

29
Only for External Pilot Vacuum Release Valve with Restrictor SY3000/5000 Series

Restrictor Flow Rate Characteristics [Fluid passage: 1(P)→2(B)]


SY3A0R SY5A0R

500 500
Flow rate [L/min (ANR)]

Flow rate [L/min (ANR)]


400 400
0.6 MPa 0.6 MPa
0.45 MPa 0.45 MPa
300 300
0.3 MPa 0.3 MPa
0.15 MPa 0.15 MPa
200 200

100 100

0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Number of restrictor rotations Number of restrictor rotations

SY3A3R-C4 SY5A3R-C4

500 500
Flow rate [L/min (ANR)]

Flow rate [L/min (ANR)]

400 400
0.6 MPa 0.6 MPa
0.45 MPa 0.45 MPa
300 300
0.3 MPa 0.3 MPa
0.15 MPa 0.15 MPa
200 200

100 100

0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Number of restrictor rotations Number of restrictor rotations

SY3A3R-C6 SY5A3R-C6

500 500
Flow rate [L/min (ANR)]

Flow rate [L/min (ANR)]

0.6 MPa 0.6 MPa


400 400 0.45 MPa
0.45 MPa
0.3 MPa 0.3 MPa
300 300
0.15 MPa 0.15 MPa

200 200

100 100

0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Number of restrictor rotations Number of restrictor rotations

SY5A3R-C8

500
Flow rate [L/min (ANR)]

400 0.6 MPa


0.45 MPa
300 0.3 MPa
0.15 MPa
200

100

0
0 1 2 3 4 5 6
Number of restrictor rotations
30
SY3000/5000 Series

Circuit Example
<Example 1: When the 2-position double solenoid valve is combined with the individual EXH spacer>
Individual EXH spacer
D side U side

5(EA) 5(EA)
(Release pressure port) 1(P) 1(P)
3(EB) 3(EB)
X X
(SY3200) (SY3200) (SY3A0R) (SY3A0R) (SY3A0R)
Vacuum release valve
with restrictor

2-position double Individual EXH spacer

SOL.b

SOL.b

SOL.b
solenoid valve

SOL.a

SOL.a

SOL.a
4(A) 2(B) 4(A) 2(B) 3/5(E') 3/5(E') 3/5(E')
2(B) Vacuum pressure port 2(B) Vacuum pressure port 2(B) Vacuum pressure port
Vacuum pad port Vacuum pad port Vacuum pad port

<Example 2: When the 2-position double solenoid valve is combined with the individual EXH block and blocking disk>
D side U side

5(EA) 5(EA)
(Release pressure port) 1(P) 1(P)
3(EB) 3(EB)
X X
(SY3200) (SY3A0R) (SY3A0R) (SY3200)
Vacuum release valve
Individual EXH block
2-position double
with restrictor ( EXH block)
Individual

2-position double
solenoid valve
solenoid valve
SOL.b

SOL.b
SOL.a

SOL.a

4(A) 2(B) 4(A)2(B) 4(A) 2(B)


3/5(E') 2(B) 2(B)
∗ For standard valve to be combined, both the internal Vacuum pressure port Vacuum pad port Vacuum pad port
pilot and external pilot can be selected. If the pres-
sure drop may occur when the 1(P) port releases the
vacuum, use the external pilot type.

31
Only for External Pilot Vacuum Release Valve with Restrictor SY3000/5000 Series

Dimensions: SY3000
Side ported SY3A0R
10 1.2 Restrictor

( Tightening torque of needle valve lock


)

(With needle fully open 55.7)


nut should not exceed 0.3 N·m.

52.5
(For E type: 60.2)
62.3 (For F type)

30.1
28.4
56.6

83.2
51.1
26.8 12.9
31.8
A

9.4
B

(Light/surge voltage suppressor) 2 x Ø 2.1


(For manifold mounting)
Manual override

( Push-turn locking slotted type:


Press, then rotate it. )
4(A): Blue
2(B): Yellow

Top ported SY3A3R

Restrictor
10 1.2 ( Tightening torque of needle valve lock
)
(3.2)

nut should not exceed 0.3 N·m.


(With needle fully open 55.7)
52.5
43.8
(For E type: 60.2)
62.3 (For F type)

30.1
28.4
56.6

83.2
51.1
26.8 12.9
11 20.8
A

9.4
B

(Light/surge voltage suppressor) 2 x Ø 2.1


(For manifold mounting)
Manual override
One-touch fitting
( Push-turn locking slotted type:
Press, then rotate it. ) [2(B) port]
4(A): Blue Applicable tubing O.D.: Ø 4, Ø 5/32"
2(B): Yellow : Ø 6, Ø 1/4"

32
SY3000/5000 Series

Dimensions: SY5000
Side ported
SY5A0R
Bottom ported

Restrictor
1.3 15
( Tightening torque of needle valve lock
nut should not exceed 0.3 N·m. )

(With needle fully open 56.5)


53.3
(For E type: 60.2)
62.3 (For F type)

30.1
27.6
56.6

103.4
71.3
(Light/surge voltage suppressor) 39.8 17.5
44.7

1.3
12.6
BA

15
Manual override
2 x Ø 3.2
( Push-turn locking slotted type:
Press, then rotate it. ) (For manifold mounting)
4(A): Blue
2(B): Yellow

Top ported SY5A3R


Restrictor
1.3 15
( Tightening torque of needle valve lock
)
(4.9)

nut should not exceed 0.3 N·m.


(With needle fully open 56.5)
53.3
45.5
(For E type: 60.2)
62.3 (For F type)

30.1
27.6
56.6

103.4
71.3
(Light/surge voltage suppressor)
39.8 17.5
14.5 30.2
1.3
12.6
BA

15

Manual override 2 x Ø 3.2

( Push-turn locking slotted type:


Press, then rotate it. ) (For manifold mounting)
One-touch fitting
4(A): Blue
[2(B) port]
2(B): Yellow
Applicable tubing O.D.: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"

33
RoHS
SY5000/7000 Series
Valve with Pressure Sensor
Mountable manifold
Metal base: SS5Y5/7-50/51 type manifold
Connector connecting base: SS5Y5/7-10/11 type manifold How to Order Valves (With mounting screw))

SY 5 1 3 0 5 1 C6 P2
q w e r t y u i o !0 !1 !2 !3
Top ported
q Series o Light/surge voltage suppressor !1 A, B port size
5 SY5000 and common specification One-touch fitting (Metric)
7 SY7000 Surge voltage Common Symbol A, B port SY5000 SY7000
Symbol With light
suppressor specification C6 Ø6  
w Type of actuation — — —
1 2-position
Single R
U


Non-polar
!2 Type of mounting screw
2 Double
— Round head combination screw
3 Closed centre S — Positive
 B Hexagon socket head cap screw
4 3-position Exhaust centre Z  common
Round head combination screw
5 Pressure centre NS — Negative K (Drop prevention type)
A∗1 N.C./N.C. NZ  common
Hexagon socket head cap screw
4-position
B∗1 dual 3-port
N.O./N.O. ∗ For the non-polar type, be careful of surge volt- H (Drop prevention type)
C∗1 N.C./N.O. age intrusion. Refer to page 317 for details.
∗ For “K” and “H,” the valve body cover has a
∗1 Only the rubber seal type is available for the ∗ Only “Z” and “NZ” are available with a power
drop prevention construction to stop the
4-position dual 3-port valve. saving circuit.
mounting screws from falling out when the
∗ Select “R,” “U,” “S,” or “Z” for the valve when the
valve is removed for maintenance, etc.
e Seal type SI unit output polarity is positive common.
Select “R,” “U,” “NS,” or “NZ” for the valve when
∗ When ordering a valve individually, the
0 Rubber seal base gasket is not included.
the SI unit output polarity is negative common.
1 Metal seal Since the base gasket is attached to the

r Pilot type !0 Manual override manifold, please order the base gasket sepa-
rately if it is needed for maintenance. Refer to
— Internal pilot —: D: page 222 for base gasket and mounting
Non-locking Push-turn screw part numbers
R External pilot
push type locking ∗ “B” and “H” cannot be selected for the individ-
t Back pressure check valve
(Built-in valve type)
slotted
type
ual SUP/EXH spacer assembly or interface
regulator.

H
None
Built-in !3 Pressure sensor
E: F: Symbol Included quantity
∗ Only the rubber seal type is available. A mani-
fold installed type is available if a back pres- Push-turn Slide locking P1 1 pc.
sure check valve with a metal seal is required. locking type P2 2 pcs.
Refer to page 2 3 6 for ordering examples. lever ∗ The top-ported type valve and the C 6 (Ø 6 )
However, it is not recommended to use the type One-touch fitting are used.
built-in valve type and the manifold installed ∗ The PSE 5 4 0 -R 0 6 pressure sensor is
type at the same time because it will reduce included in the product package.
the flow. ∗ When “P1” is selected, one plug (KQ2P-06) is
∗ The built-in valve type back pressure check valve is included in the product package.
not available for the 3-position type or the SY7000.

y Pilot valve option How to Order Manifold Assembly


— Standard (0.7 MPa)
B Quick response type (0.7 MPa)
K∗1 High pressure type (1.0 MPa) Example (SS5Y5-10F1-)
∗1 Only the metal seal type is available for the 2-position double (24 VDC)
high pressure type. SS5Y5-10F1-05D-C8 SY5230-5U1-C6-P2 (1 set) 3-position closed centre (24 VDC)
…1 set (Type 10 5-station manifold base part no.) 2-position single (24 VDC) SY5330-5U1-C6-P2 (1 set)

u Coil type ∗ SY5130-5U1-C6-P1


…2 sets (2-position single part no.)
SY5130-5U1-C6-P2 (1 set)
2-position single (24 VDC)
— Standard ∗ SY5130-5U1-C6-P2
SY5130-5U1-C6-P1 (2 sets)
With power saving circuit …1 set (2-position double part no.)
T (Continuous duty type) ∗ SY5230-5U1-C6-P2
…1 set (2-position double part no.)
∗ Be sure to select the power saving circuit type ∗ SY5330-5U1-C6-P2
The illustration shows a
mounting example. The
if the valve is to be continuously energised for …1 set (3-position closed centre part no.) pressure sensor and
long periods of time. plug are included in the ide
The asterisk denotes the symbol product package. Us
∗ Be careful of the energising time when the for the assembly. Stati
ons
power saving circuit is selected. Refer to page Prefix it to the part numbers of the
3

valve, etc. Manifold base (5 stations)


2

316 for details.


1

SS5Y5-10F1-05D-C8 ide
Ds
· For the valve arrangement, the valve closest to the D side is considered the 1st station.
i Rated voltage · Under the manifold part number, state the valves to be mounted in order starting with the 1 st station as shown in the
figure above. If the arrangement becomes too complicated, specify the details on a manifold specification sheet.
5 24 VDC
6 12 VDC
∗ The applicable rated voltage varies depending
on the manifold wiring type.
34
SY5000/7000 Series

Pressure Sensor Specifications

Model PSE540
Rated pressure range 0 to 1 MPa∗1
Power supply voltage 12 to 24 VDC ±10 %, Ripple (p-p) 10 % or less (with reverse connection protection)
Current consumption 15 mA or less
Output specifications Analogue output 1 to 5 V (within rated pressure range), 0.6 to 1 V (within extension analogue output range), Output impedance: Approx. 1 k Ω
Linearity ±0.7 % F.S. or less
Environment Enclosure∗2 IP40
Temperature characteristics ±2 % F.S. (25 °C reference)
Sensor cable Oilproof heavy-duty vinyl cable (ellipse), 3 cores, 2.7 x 3.2, 3 m, Conductor area: 0.15 mm2, Insulator O.D.: 0.9 mm
∗1 Set the pressure within the operating pressure range of the valve.
∗2 Please note that even if the manifold is IP67, the product will remain IP40.

Dimensions

SY5000-P2 A side pressure sensor Plug B side pressure sensor


1.3 15

3000 3000

68
63
62.3 (For F type)
(For E type: 60.2)

33.6
30.1
27.6
56.6

37.4
50.6 (For 3-position)

103.4
71.3
39.8 17.5
(Light/surge voltage suppressor) 14.5
12.6
B A

Manual override Manual override part 2 x Ø 3.2


(For manifold mounting)
( Push-turn locking slotted type:
Press, then rotate it. ) 30.7 (For 3-position)
84.5 (For 3-position)
4(A) port side : Blue
116.6 (For 3-position)
2(B) port side : Yellow

SY7000-P2 Plug B side pressure sensor


18 2.2 A side pressure sensor

3000 3000
71.1
66.1
(For E type: 60.2)
(For F type: 62.3)

33.3
31.3

37
56.6

45.6
62.1 (For 3-position)

116.7
84.6
(Light/surge voltage suppressor) 47 20.6
28.4 3 x Ø 3.2
(For manifold mounting)
16.8
B A

Manual override 37.1 (For 3-position)

(
Push-turn locking slotted type:
Press, then rotate it. ) 101.1 (For 3-position)

4(A) port side : Blue (For rubber seal) 133.2 (For 3-position)
: Grey (For metal seal)
2(B) port side : Yellow

35
SY3000/5000/7000 Series
Made to Order
Please contact SMC for detailed dimensions, specifications, and lead times.

Symbol
1 Main Valve Fluororubber Specification -X90
Fluororubber is used for rubber parts of the main valve to allow use in applications such as the following.
· When using a lubricant other than the recommended turbine oil, and there is a possibility of malfunction due to swelling of the spool valve seals.

Applicable valves series SY3 03 0, SY5 03 0, SY7 03 0 (Only rubber seal type)

3 0
SY 5 3 0 1 X90
7

Entry is the same as standard products.


Specifications and performance are the same as standard products.

Symbol
2 With Safety Slide Locking Manual Override -X13
A safety lock is added to the slide locking manual override.
(Refer to page 4.)
3 00
SY 5 31 G1 X13
7

Entry is the same as standard products.


Specifications and performance are the same as standard products.

Symbol
3 2-Position Single Solenoid Valve with Built-in Return Spring (Only rubber seal type) -X350
A 2-position single solenoid valve with a spring built into the main valve
The main valve returns to origin (the OFF position) via the spring when it is not pressurised.
3 0
SY 5 1 3 0 1 X350
7

Rubber seal Entry is the same as standard products.


type Specifications and performance are the
same as standard products. Internal pilot type External pilot type
X
4(A) 2(B) 4(A) 2(B)

∗ For the external pilot type, exhaust the external pilot (X) port and the main pressure
simultaneously. (EA)5 1 3(EB) (EA)5 1 3(EB)
If the main pressure cannot be exhausted due to the system specifications, (P) (P)
please contact SMC separately.

∗ The manual option is only applicable to the non-locking push type.

36
37
Plug-in Connector Connecting Base

Side ported

Bottom ported

Top ported

38
SY3000/5000/7000 Series Type 10, 11, 12
Plug-in Connector Connecting Base

Manifold Specifications

D-sub Terminal Terminal Lead Circular


Flat ribbon cable block box Serial wiring
connector (Spring type) block box wire connector
SA3 type
Model SA2 type S3 type
S6 type SA type (EX500) (EX500) (EX120)
F type FW type P type PG type PH type TC type T type L type M type S type
(EX600) (EX245) S4 type (EX250) S8 type
(EX126) (EX180)
(EX260)
Manifold type Plug-in connector connecting base
SUP/EXH port type Common SUP/EXH (Common for 3/5 port)
2 to 16
stations
2 to 18 2 to 8 2 to 24 2 to 20 2 to 16 2 to 24 (EX120)
Valve stations 2 to 24 stations 2 to 24 stations
stations stations stations stations stations stations 2 to 24
stations
(EX180)
D-sub Flat ribbon cable connector
connector with strain relief
Dedicated Conforming to MIL-C-83503
Conforming to
connector (Refer to page 60.)
Applicable connector MIL-C-24308 —
(Refer to
JIS-X-5101 Socket: Socket: Socket:
page 57.)
(Refer to 26 pins 20 pins 10 pins
page 57.) MIL type MIL type MIL type
Negative Positive common,
Internal wiring Positive common, Negative common
common Negative common
Ø 8 One-touch fitting
SY3000
Ø 5/16" One-touch fitting

1(P), 3/5(E) Ø 10 One-touch fitting


port
SY5000
Ø 3/8" One-touch fitting
Ø 12 One-touch fitting
SY7000
Port Ø 1/2" One-touch fitting
size Ø 2 One-touch fitting, Ø 3.2 One-touch fitting, Ø 4 One-touch fitting, Ø 6 One-touch fitting
SY3000
Ø 1/8" One-touch fitting, Ø 5/32" One-touch fitting, Ø 1/4" One-touch fitting

4(A), 2(B) Ø 4 One-touch fitting, Ø 6 One-touch fitting, Ø 8 One-touch fitting


port
SY5000
Ø 5/32" One-touch fitting, Ø 1/4" One-touch fitting, Ø 5/16" One-touch fitting
Ø 6 One-touch fitting, Ø 8 One-touch fitting, Ø 10 One-touch fitting, Ø 12 One-touch fitting
SY7000
Ø 1/4" One-touch fitting, Ø 5/16" One-touch fitting, Ø 3/8" One-touch fitting
IP67∗1

( ) (( ))
IP67∗1 IP67∗1 EX260 D-sub
EX500 GW communication
Enclosure (Based on IEC60529) IP40 IP67∗1 IP40 IP67∗1
( )
I/O Unit:
partially
IP40
IP65 Unit, Input connector: IP40
Unit: IP65 EX500 GW
Unit: IP65
IP20

∗1 In the case of a metal seal, there are restrictions in the operating environment. Refer to the “Specific Product Precautions” on page 314.

39
Type 10, 11, 12
Plug-in Connector Connecting Base SY3000/5000/7000 Series

Manifold Flow Rate Characteristics∗1/Manifold Weight


Valve Seal Type: Rubber Seal
Side Ported (Type 10)
Port size Flow rate characteristics
Manifold Valve Weight: W [g]∗2
1, 3/5 4, 2 1 → 4/2 (P → A/B) 4/2 → 3/5 (A/B → E)
model model (n: stations)
(P, E) (A, B) C [dm3/(s·bar)] b Q [l/min (ANR)]∗3 C [dm3/(s·bar)] b Q [l/min (ANR)]∗3
SY3100
1.4 0.30 356 1.6 0.19 381
SY3200
SY3300 1.3 0.28 326 1.2 0.40 326
SY3400 1.2 0.27 299 1.6 0.29 404
SS5Y3 C8 C6 28.9 n + 293
SY3500 1.4 0.31 358 1.1 0.36 291
SY3A00 1.3 0.26 322 1.5 0.27 324
SY3B00 1.3 0.26 322 1.5 0.27 324
SY3C00 1.3 0.26 322 1.5 0.27 324
SY5100
3.3 0.30 839 3.6 0.17 848
SY5200
SY5300 3.1 0.32 793 2.9 0.31 742
SY5400 3.1 0.32 798 3.7 0.23 902
SS5Y5 C10 C8 74.7 n + 398
SY5500 3.4 0.32 876 2.9 0.31 742
SY5A00 2.9 0.32 747 3.2 0.25 789
SY5B00 2.8 0.31 717 2.9 0.26 719
SY5C00 2.9 0.32 747 3.1 0.25 671
SY7100
6.2 0.23 1511 5.9 0.20 1413
SY7200
SY7300 4.8 0.25 1184 4.4 0.36 1164
SY7400 4.8 0.25 1184 6.6 0.27 1647
SS5Y7 C12 C12 106.6 n + 496
SY7500 7.1 0.25 1751 4.4 0.36 1164
SY7A00 5.4 0.25 1332 5.1 0.29 1289
SY7B00 5.4 0.24 1324 5.1 0.31 1305
SY7C00 5.4 0.25 1332 5.1 0.29 1289

Valve Seal Type: Rubber Seal


Bottom Ported (Type 11)
Port size Flow rate characteristics
Manifold Valve Weight: W[g]∗2
1, 3/5 4, 2 1 → 4/2 (P → A/B) 4/2 → 3/5 (A/B → E)
model model (n: stations)
(P, E) (A, B) C [dm3/(s·bar)] b Q [l/min (ANR)]∗3 C [dm3/(s·bar)] b Q [l/min (ANR)]∗3
SY5100
SS5Y5 C10 C8 3.3 0.29 834 4.2 0.26 1042 76.8 n + 445
SY5200
SY7100
SS5Y7 C12 C12 6.2 0.25 1529 6.6 0.21 1428 117.9 n + 532
SY7200

Valve Seal Type: Rubber Seal


Top Ported (Type 12)
Port size Flow rate characteristics
Manifold Valve Weight: W [g]∗2
1, 3/5 4, 2 1 → 4/2 (P → A/B) 4/2 → 3/5 (A/B → E)
model model (n: stations)
(P, E) (A, B) C [dm3/(s·bar)] b Q [l/min (ANR)]∗3 C [dm3/(s·bar)] b Q [l/min (ANR)]∗3
SY3130
SS5Y3 C8 C6 1.2 0.29 303 1.3 0.19 310 25.1 n + 314
SY3230
SY5130
SS5Y5 C10 C8 2.8 0.27 699 3.8 0.23 926 66.3 n + 417
SY5230
SY7130
SS5Y7 C12 C12 5.6 0.31 1433 5.7 0.24 1397 84.1 n + 519
SY7230
∗1 The value is for manifold base with 5 stations and individually operated 2-position type.
∗2 Weight: W is the value of the internal pilot, and D-sub connector manifold with One-touch fitting straight piping type.
To obtain the weight with valves attached, add the valve weights given on page 19 for the appropriate number of stations.
∗3 These values have been calculated according to ISO 6358 and indicate the fl ow rate under standard conditions with an inlet pressure of 0.6 MPa
(relative pressure) and a pressure drop of 0.1 MPa.
∗ Calculation of effective area S and sonic conductance C: S = 5.0 x C
40
SY3000/5000/7000 Series

Manifold Flow Rate Characteristics∗1/Manifold Weight


Valve Seal Type: Metal Seal
Side Ported (Type 10)
Port size Flow rate characteristics
Manifold Valve Weight: W [g]∗2
1, 3/5 4, 2 1 J 4/2 (P J A/B) 4/2 J 3/5 (A/B J E)
model model (n: stations)
(P, E) (A, B) C [dm3/(s·bar)] b Q [l/min (ANR)]∗3 C [dm3/(s·bar)] b Q [l/min (ANR)]∗3
SY3101
1.2 0.19 286 1.3 0.18 308
SY3201
SS5Y3 SY3301 C8 C6 0.8 0.19 191 0.8 0.35 210 28.9 n + 293
SY3401 0.8 0.19 191 1.1 0.26 273
SY3501 0.9 0.21 195 0.7 0.32 151
SY5101
2.7 0.24 662 3.1 0.17 730
SY5201
SS5Y5 SY5301 C10 C8 2.3 0.21 554 2.0 0.24 490 74.7 n + 398
SY5401 2.3 0.21 554 2.7 0.18 640
SY5501 2.5 0.21 541 2.0 0.24 433
SY7101
4.4 0.14 1020 4.4 0.17 1073
SY7201
SS5Y7 SY7301 C12 C12 3.4 0.12 780 3.3 0.24 800 106.6 n + 496
SY7401 3.4 0.12 780 4.9 0.18 1161
SY7501 5.0 0.12 1082 3.3 0.24 714

Valve Seal Type: Metal Seal


Bottom Ported (Type 11)
Port size Flow rate characteristics
Manifold Valve Weight: W [g]∗2
1, 3/5 4, 2 1 J 4/2 (P J A/B) 4/2 J 3/5 (A/B J E)
model model (n: stations)
(P, E) (A, B) C [dm3/(s·bar)] b Q [l/min (ANR)]∗3 C [dm3/(s·bar)] b Q [l/min (ANR)]∗3
SY5101
SS5Y5 C10 C8 2.8 0.25 690 3.5 0.15 816 76.8 n + 445
SY5201
SY7101
SS5Y7 C12 C12 4.6 0.16 1078 4.7 0.18 1017 117.9 n + 532
SY7201

Valve Seal Type: Metal Seal


Top Ported (Type 12)
Port size Flow rate characteristics
Manifold Valve Weight: W [g]∗2
1, 3/5 4, 2 1 J 4/2 (P1 J A/B) 4/21 J 3/5 (A/B1 J E)
model model (n: stations)
(P, E) (A, B) C [dm3/(s·bar)] b Q [l/min (ANR)]∗3 C [dm3/(s·bar)] b Q [l/min (ANR)]∗3
SY3131
SS5Y3 C8 C6 1.2 0.16 281 1.3 0.18 308 25.1 n + 314
SY3231
SY5131
SS5Y5 C10 C8 2.6 0.18 616 3.0 0.16 703 66.3 n + 417
SY5231
SY7131
SS5Y7 C12 C12 3.9 0.21 844 4.1 0.14 887 84.1 n + 519
SY7231
∗1 The value is for manifold base with 5 stations and individually operated 2-position type.
∗2 Weight: W is the value of the internal pilot, and D-sub connector manifold with One-touch fitting straight piping type.
To obtain the weight with valves attached, add the valve weights given on page 19 for the appropriate number of stations.
∗3 These values have been calculated according to ISO 6358 and indicate the fl ow rate under standard conditions with an inlet pressure of 0.6 MPa
(relative pressure) and a pressure drop of 0.1 MPa.
∗ Calculation of effective area S and sonic conductance C: S = 5.0 x C

41
Type 10, 11, 12
Plug-in Connector Connecting Base SY3000/5000/7000 Series

Connector Wiring Layout


For both serial and parallel wiring, additional valves are sequentially assigned pins on the connector.
This makes it completely unnecessary to disassemble the connector unit.

 Single solenoid valve is installed to all double wiring. (in the case of all double wiring)
(Manifold specification sheet is not necessary.)
Solenoid Connector side
(D-sub connector, etc.)

Common (+, –)
SOL.a
Station 1
SOL.b
SOL.a Station 2
Unused terminal
SOL.a Station 3
SOL.b

···
Double solenoid Single solenoid Double solenoid
Station 3 (Double wiring) Station 1
Station 2

 Single/double wiring are mixed.


(Manifold specification sheet is necessary.) Connector side
Solenoid
(D-sub connector, etc.)

Common (+, –)
SOL.a Station 1
SOL.b
SOL.a Station 2
SOL.a
SOL.b Station 3
···

Double solenoid Single solenoid Double solenoid


Station 3 Station 2 Station 1

∗ These diagrams are for the purpose of explanation, and differ from the connector wiring used for testing.

42
Plug-in Connector Connecting Base
Type 10
Side Ported D-sub Connector Flat Ribbon Cable
Type 11
Bottom Ported
SY3000/5000/7000 Series ®

RoHS
How to Order Manifolds

Refer to pages 180 (SY5000) and SS5Y 3 10 F 1 05 U C6


181 (SY7000) for the dimensions
of Type 11/Bottom-ported type.
q w e r t y u i o
q Series w Type e Connector type
3 SY3000 10 Side ported F: D-sub connector <IP40> FW: D-sub connector <IP67> P: Flat ribbon cable
5 SY5000 11 Bottom ported∗1 (25 pins) (25 pins) (26 pins)
7 SY7000 ∗1 The SY5000 manifold base is used
for the bottom-ported SY3000.
When ordering, refer to the “Plug-in
Manifold Mixed Mounting Type”
(from page 185).

r Connector entry direction


1: Upward 2: Lateral ∗ The connector entry PG: Flat ribbon cable PH: Flat ribbon cable
direction for connector (20 pins) (10 pins)
type "FW" D-sub con-
nector <IP67> cannot
be rotated. If it is nec-
essary to change, or-
der the connector
block assembly (page
227) separately.

t Valve stations
F/FW: D-sub connector (25 pins) P: Flat ribbon cable (26 pins)
Symbol Stations Note Symbol Stations Note
How to Order Manifold Assembly 02 2 stations 02 2 stations
Double wiring∗1 Double wiring∗1

12 12 stations 12 12 stations
Example (SS5Y3-10F1-) 02 2 stations Specified layout∗2 02 2 stations Specified layout∗2
2-position double (24 VDC)

(Up to 24 solenoids (Up to 24 solenoids


2-position single (24 VDC) SY3200-5U1 (1 set)
24 24 stations available) 24 24 stations available)
SY3100-5U1 (3 sets) 3-position closed
centre (24 VDC) PG: Flat ribbon cable (20 pins) PH: Flat ribbon cable (10 pins)
SY3300-5U1 (1 set) Symbol Stations Note Symbol Stations Note
02 2 stations 02 2 stations
Double wiring∗1 Double wiring∗1

09 9 stations 04 4 stations
LOC 02 2 stations Specified layout∗2 02 2 stations Specified layout∗2
ide
K

FRE Us (Up to 18 solenoids (Up to 8 solenoids


E s
on 18 18 stations available) 08 8 stations available)
ati
St
Manifold base 3 ∗1 Double wiring: 2-position single, double, 3-position, and 4-position
2 valves can be used on all manifold stations.
(5 stations) 1
e Use of a 2-position single solenoid will result in an unused control
SS5Y3-10F1-05D-C6
D sid
signal. If this is not desired, order with a specified layout.
∗2 Specified layout: Indicate the wiring specifications on the manifold
SS5Y3-10F1-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.) specification sheet. (Note that 2-position double, 3-position, and 4-
∗SY3100-5U1 ················· 3 sets (2-position single part no.) position valves cannot be used where single wiring has been specified.)
∗SY3200-5U1 ················· 1 set (2-position double part no.) ∗ This also includes the number of the blanking plate assembly.
∗SY3300-5U1 ················· 1 set (3-position closed centre part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
• For the valve arrangement, the valve closest to the D side is considered the 1st station.
• Under the manifold part number, state the valves to be mounted in order starting
with the 1st station as shown in the figure above. If the arrangement becomes too
complicated, specify the details on a manifold specification sheet.
∗ When mixing top-ported configurations, select from those listed on page 56.
In such cases, use caution as there is also output on the A and B ports on the base side.
Specify on the manifold specification sheet if plugs are required for the A and B ports
on the base side.
43
Plug-in Connector Connecting Base SY3000/5000/7000 Series

y P, E port entry u SUP/EXH block assembly o Mounting and Option


U U side (2 to 10 stations) — Internal pilot Option DIN Rail Option
Symbol Mounting
D D side (2 to 10 stations) Internal pilot, Name plate Station number — Direct mounting
S Built-in silencer
B Both sides (2 to 24 stations) — — — 0 Without DIN rail (with bracket)
Direct
R External pilot AA   3 For 3 stations Specify a longer rail
mounting



∗ 3/5(E) port is plugged for the BA — than the total length
built-in silencer type. D — — 24 For 24 stations of specified stations.
DIN rail
A  
mounting
B  —
∗ Enter the number of stations inside  when it is larger than the number
of valve stations. (Refer to “DIN Rail Option” above.)
∗ Only direct mounting is available for the type 11 bottom-ported type.
∗ Refer to page 319 for the fixation of DIN rail mounting type manifold.

i A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)


Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 Ø2  — — — — N1 Ø 1/8"  — — — —
C3 Ø 3.2  — — — — N3 Ø 5/32"   —  —
Straight

C4 Ø4   —  — N7 Ø 1/4"     
Straight

C6 Ø6      N9 Ø 5/16" —    
C8 Ø8 —     N11 Ø 3/8" — —  — 
C10 Ø 10 — —  —  CM∗1 Straight port, mixed sizes     
C12 Ø 12 — —  —  LN3 Ø 5/32"  — — — —
Upward

CM∗1 Straight port, mixed sizes      LN7 Ø 1/4"   — — —


L4 Ø4   — — — LN9 Ø 5/16" —  — — —
L6 Ø6    — — LN11 Ø 3/8" — —  — —
Upward

Elbow∗2

L8 Ø8 —   — — BN3 Ø 5/32"  — — — —
Downward

L10 Ø 10 — —  — — BN7 Ø 1/4"   — — —


L12 Ø 12 — —  — — BN9 Ø 5/16" —  — — —
Elbow∗2

B4 Ø4   — — — BN11 Ø 3/8" — —  — —
Downward

B6 Ø6    — — Elbow port, mixed sizes


LM∗1 (Including upward and    — —
B8 Ø8 —   — — downward piping)
B10 Ø 10 — —  — — P, E port size
Ø 5/16" Ø 3/8" Ø 1/2" Ø 3/8" Ø 1/2"
B12 Ø 12 — —  — — (One-touch fittings)
Elbow port, mixed sizes
LM∗1 (Including upward and    — —
downward piping)
P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).

Protective class
class # (Mark: )
44
SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

q Series y Pilot valve option !0 Manual override


3 SY3000 — Standard (0.7 MPa) —: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K∗1 High pressure type (1.0 MPa) push type locking
∗1 Only the metal seal type is available for the slotted
high pressure type. type

w Type of actuation
1 Single
2
2-position
Double u Coil type E:
Push-turn
F:
Slide locking
3 Closed centre — Standard locking lever type
4 3-position Exhaust centre T With power saving circuit (Continuous duty type) type
5 Pressure centre ∗ Be sure to select the power saving circuit
A∗1 4-position N.C./N.C. type if the valve is to be continuously
B∗1 dual N.O./N.O. energised for long periods of time.
C∗1 3-port N.C./N.O. ∗ Be careful of the energising time when the ∗ Refer to page 36 for the safety slide locking
power saving circuit is selected. Refer to page manual override.
∗1 Only the rubber seal type is available for the 316 for details.
4-position dual 3-port valve.

i Rated voltage !1 Type of mounting screw


e Seal type 5 24 VDC
— Round head combination screw
0 Rubber seal B Hexagon socket head cap screw
6 12 VDC
1 Metal seal K Round head combination screw (Drop prevention type)
H Hexagon socket head cap screw (Drop prevention type)
∗ For “K” and “H,” the valve body cover has a
o Light/surge voltage suppressor
r Pilot type and common specification
drop prevention construction to stop the
mounting screws from falling out when the
— Internal pilot
Surge voltage Common
valve is removed for maintenance, etc.
R External pilot Symbol With light ∗ When ordering a valve individually, the
suppressor specification
base gasket is not included.
— — — Since the base gasket is attached to the
R — Non-polar manifold, please order the base gasket
t Back pressure check valve U  separately if it is needed for maintenance.
Refer to page 222 for base gasket and
(Built-in valve type) S — Positive
 mounting screw part numbers.
Z  common
— None ∗ “B” and “H” cannot be selected for the
H Built-in NS — Negative individual SUP/EXH spacer assembly,
NZ  common interface regulator, or double check spacer
∗ Only the rubber seal type is available. A
manifold installed type is available if a back ∗ For the non-polar type, be careful of surge assembly with residual pressure release
pressure check valve with a metal seal is voltage intrusion. valve.
required. Refer to page 236 for ordering Refer to page 317 for details.
examples. However, it is not recommended ∗ Only “Z” and “NZ” types are available with a
to use the built-in valve type and the manifold power saving circuit.
installed type at the same time because it will
reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.

Protective class
class # (Mark: )
45
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY3000 Series Connector Connecting Base D-sub Connector (IP40)

C2
U
SS5Y3-10F 12 - Stations D - C3, N1
C4, N3 (D)
B C6, N7
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 2
(Station 1)---(Station n) : Ø 3.2, Ø 1/8"
6.1 : Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"

1 P 1 P
(62.7)

63.1
13.6
10.6
56.6
48.6

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

21.6
4 A4 A4 A4 A4 A
18

(For DIN rail


mounting)
(7.5)
One-touch fitting

(11.8)
(Pitch)
[1(P), 3/5(E) port] 31.4 15.5 P = 10.5 (17.8)
Applicable tube O.D.: Ø 8, Ø 5/16"

Applicable connector: D-sub ( JIS-X-5101


MIL-C-24308 )
equivalent
D side U side
Manual override ∗1
DIN rail holding screw (L5)
(For DIN rail mounting) (8)
L1
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor) : Grey (For metal seal)
2(B) port side : Yellow
(5.5)

(8)

LOCK
B A B A B A B A B A
(35)

92.6

14 A 14 A 14 A 14 A 14 A
70.6
83

60.5

FREE
(40.9)

44.8
4.6

12 B 12 B 12 B 12 B 12 B

2 x M2.6
4.6
9.5

1.7
N7: 7.4 )
(4.9)

3.6

2 x 4-40 UNC
(Connector entry
4 x M4 mounting hole [4(A), 2(B) port:
(C6:

N (inch size)] upward direction)


(Fitting for the type with P/E
19.6 L2 1.5 ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10F2-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 88.6 99.1 109.6 120.1 130.6 141.1 151.6 162.1 172.6 183.1 193.6 204.1 214.6 225.1 235.6 246.1 256.6 267.1 277.6 288.1 298.6 309.1 319.6
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 123 135.5 148 160.5 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 298 298 310.5 323 335.5 348 360.5
L4 112.5 125 137.5 150 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275 287.5 287.5 300 312.5 325 337.5 350
L5 20.5 21.5 22.5 23.5 18 19 20 21 22 23 18 19 20 21 22 23 23.5 18.5 19.5 20.5 21.5 22.5 23.5

46
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY5000 Series Connector Connecting Base D-sub Connector (IP40)

U C4, N3
SS5Y5-10F 12 - Stations D - C6, N7 (D)
B C8, N9
One-touch fitting
[4(A), 2(B) port]
(Station 1)----------- (Station n) Applicable tube O.D.: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
6.1

14.1
1 P 1 P

73.2
(62.7)

8.7
2 B2 B2 B2 B2 B
56.6
48.6

12.4
33.4

3/5 E 3/5 E

29.1
4 A4 A4 A4 A4 A

One-touch fitting

(For DIN rail


(7.5)

mounting)
[1(P), 3/5(E) port] (Pitch)

(11.8)
Applicable tube O.D.: Ø 10, Ø 3/8" 35.9 18 P = 16 (20.5)

(
JIS-X-5101
)
Applicable connector: D-sub MIL-C-24308 equivalent

D side U side
Manual override ∗1
(L5) L1
DIN rail holding screw
(For DIN rail mounting) (8)
( Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor)
: Grey (For metal seal)
DIN rail 2(B) port side : Yellow
(5.5)

(8)

LOCK
BA BA BA BA BA
(35)
70.6

14 A 14 A 14 A 14 A 14 A
97.5

113.4

FREE
81.2
(61.7)

65.6
5.5

12 B 12 B 12 B 12 B 12 B
10.9
30.3

4.7

2 x M2.6
(5.9)
(8.3)

4 x M5 mounting hole
2 x 4-40 UNC
21.9 L2 1.5 (Fitting for the type with P/E [4(A), 2(B) port:
ports on the U and/or D sides) N (inch size)]
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5) (Connector entry upward direction)
(L3)

∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10F2-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 108.4 124.4 140.4 156.4 172.4 188.4 204.4 220.4 236.4 252.4 268.4 284.4 300.4 316.4 332.4 348.4 364.4 380.4 396.4 412.4 428.4 444.4 460.4
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 148 160.5 173 198 210.5 223 235.5 260.5 273 285.5 298 323 335.5 348 373 385.5 398 410.5 435.5 448 460.5 485.5 498
L4 137.5 150 162.5 187.5 200 212.5 225 250 262.5 275 287.5 312.5 325 337.5 362.5 375 387.5 400 425 437.5 450 475 487.5
L5 23 21 19.5 24 22 20.5 18.5 23 21.5 19.5 18 22.5 20.5 19 23.5 21.5 20 18 22.5 21 19 23.5 22

47
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY7000 Series Connector Connecting Base D-sub Connector (IP40)

U C6, N7
SS5Y7-10F 12- Stations DB - C8,
C10, N11(D)
N9
C12
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 6, Ø 1/4"
(Station 1) (Station n) : Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
: Ø 12
6.1

2
82.7
1 P 1 P
2 B2 B2 B2 B2 B
(62.7)

56.6
48.6

14.2

11.1
3/5 E 3/5 E
35.2

8.7

31.6
4 A4 A4 A4 A4 A

(For DIN rail


(Pitch)

(10)
One-touch fitting (21.7)

mounting)
(14.3)
[1(P), 3/5(E) port] 39.5 20.5 P = 19
Applicable tube O.D.: Ø 12, Ø 1/2"
JIS-X-5101
D side U side
Applicable connector: D-sub
( MIL-C-24308 )
equivalent

Manual override ∗1
DIN rail holding screw (L5) L1
(For DIN rail mounting)
(8) (Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor) : Grey (For metal seal)
2(B) port side : Yellow

(8)
(DIN rail)

LOCK
B A B A B A B A B A
(35)

14 A 14 A 14 A 14 A 14 A
70.6

128.8
115

FREE
(5.5)

96.7
(77.1)

79.5
44.2

12 B 12 B 12 B 12 B 12 B
5.5
8.8

3.9

2 x M2.6
(6)
(9.3)

2 x 4-40 UNC
(17.9)

(A, B port: Ø 12)


[4(A), 2(B) port: N (inch size)]
4 x M5 mounting hole
20.7 L2 1.5 (Connector entry upward direction)
(5.3) (L4)
(Fitting for the type with P/E
(DIN rail mounting hole pitch: 12.5)
ports on the U and/or D sides)
(L3)

∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10F2-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 121.2 140.2 159.2 178.2 197.2 216.2 235.2 254.2 273.2 292.2 311.2 330.2 349.2 368.2 387.2 406.2 425.2 444.2 463.2 482.2 501.2 520.2 539.2
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 160.5 173 198 210.5 235.5 248 273 285.5 310.5 323 348 360.5 385.5 398 423 435.5 460.5 485.5 498 523 535.5 560.5 573
L4 150 162.5 187.5 200 225 237.5 262.5 275 300 312.5 337.5 350 375 387.5 412.5 425 450 475 487.5 512.5 525 550 562.5
L5 22.5 19.5 22.5 19 22 19 22 18.5 21.5 18.5 21.5 18 21 18 21 17.5 20.5 23.5 20.5 23.5 20 23 20

48
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY3000 Series Connector Connecting Base D-sub Connector (IP67)

U C2
SS5Y3-10FW 12 - Stations D - C3, N1
C4, N3 (D)
B C6, N7

(Station 1) (Station n)
One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: Ø 2, Ø 1/8"
Applicable tube O.D.: Ø 8, Ø 5/16" : Ø 3, Ø 5/32"
: Ø 4, Ø 1/4"
4.5
:Ø6

1 P 1 P
(61.1)

63.1
56.6

10.6
13.6
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

4 A4 A4 A4 A4 A

21.6
23
18

(For DIN rail


(17.8)

(7.5)
(Pitch)

mounting)
(11.8)
48.3 15.5 P=10.5

D side U side
(L5) Manual override∗1
L1
DIN rail holding screw
(15)
(Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor) : Grey (For metal seal) (Connector entry upward direction)
2(B) port side : Yellow

DIN rail

(8)
(5.5)

B A B A B A B A B A
(35)

14 A 14 A 14 A 14 A 14 A
92.6
83
70.6

60.5
(40.9)

38.7

12 B 12 B 12 B 12 B 12 B
4.6
3.4

4.6
1.7
(4.9)

)
C6: 3.6
N7: 7.4

2 x M2.6
4 x M4 mounting hole
(

2 x 4-40 UNC
[4(A), 2(B) port: N (inch size)]
36.5 L2 1.5 (Fitting for the type with P/E
ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

JIS-X-5101
Applicable connector: D-sub
( MIL-C-24308
equivalent
)

∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10FW2-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 105.5 116 126.5 137 147.5 158 168.5 179 189.5 200 210.5 221 231.5 242 252.5 263 273.5 284 294.5 305 315.5 326 336.5
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 135.5 148 160.5 173 185.5 198 198 210.5 223 235.5 248 260.5 260.5 273 285.5 298 310.5 323 323 335.5 348 360.5 373
L4 125 137.5 150 162.5 175 187.5 187.5 200 212.5 225 237.5 250 250 262.5 275 287.5 300 312.5 312.5 325 337.5 350 362.5
L5 17.5 18.5 19.5 20.5 21.5 22.5 17 18 19 20 21 22 17 18 19 20 21 22 16.5 17.5 18.5 19.5 20.5
49
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY5000 Series Connector Connecting Base D-sub Connector (IP67)

U C4, N3
SS5Y5-10FW 12 - Stations D- C6, N7 (D)
B C8, N9

(Station 1) (Station n)
One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: Ø 4, Ø 5/32"
Applicable tube O.D.: Ø 10, Ø 3/8" : Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
4.5

14.1
1 P 1 P

73.2
8.7
(61.1)

2 B2 B2 B2 B2 B
56.6

3/5 3/5
33.4

E E

29.1
23

4 A4 A4 A4 A4 A
12.4

(For DIN rail


(Pitch)

(7.5)

mounting)
(20.5)

(11.8)
50 18 P=16

D side U side
Manual override∗1

DIN rail holding screw


(L5) L1
(Push-turn locking slotted type:
Press, then rotate it. )
(15) 4(A) port side : Blue (For rubber seal)
(For DIN rail mounting) (Light/surge voltage suppressor) : Grey (For metal seal) (Connector entry upward direction)
2(B) port side : Yellow
DIN rail
(8)
(5.5)

B A B A B A B A B A
(35)

14 A 14 A 14 A 14 A 14 A
97.5
70.6

113.4
81.2
(61.7)

59.5
5.5

12 B 12 B 12 B 12 B 12 B
24.2

10.9
4.7
(5.9)
(8.3)

2 x M2.6
4 x M5 mounting hole 2 x 4-40 UNC
36 L2 1.5 [4(A), 2(B) port:
(5.3) (Fitting for the type with P/E
(L4) N (inch size)]
ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)

(L3)

Applicable connector: D-sub JIS-X-5101 equivalent


MIL-C-24308 ( )

∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10FW2-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 122.5 138.5 154.5 170.5 186.5 202.5 218.5 234.5 250.5 266.5 282.5 298.5 314.5 330.5 346.5 362.5 378.5 394.5 410.5 426.5 442.5 458.5 474.5
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 160.5 173 185.5 210.5 223 235.5 248 273 285.5 298 310.5 335.5 348 360.5 385.5 398 410.5 423 448 460.5 473 498 510.5
L4 150 162.5 175 200 212.5 225 237.5 262.5 275 287.5 300 325 337.5 350 375 387.5 400 412.5 437.5 450 462.5 487.5 500
L5 21.5 19.5 18 22.5 20.5 19 17 21.5 20 18 16.5 21 19 17.5 22 20 18.5 16.5 21 19.5 17.5 22 20.5

50
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY7000 Series Connector Connecting Base D-sub Connector (IP67)

U C6, N7
SS5Y7-10FW 12 - Stations D - C8, N9 (D)
B C10, N11
C12

(Station 1) (Station n) One-touch fitting


[4(A), 2(B) port]
One-touch fitting Applicable tube O.D.: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
[1(P), 3/5(E) port]
: Ø 10, Ø 3/8"
Applicable tube O.D.: Ø 12, Ø 1/2"
: Ø 12
4.5

2
82.7
1 P 1 P
2 B2 B2 B2 B2 B
(61.1)

56.6
11.1
3/5 E 3/5 E

8.7
35.2

31.6
4 A4 A4 A4 A4 A
23
14.2

(For DIN rail


(Pitch)

(10)
(21.7)

mounting)
(14.3)
55 20.5 P = 19

D side U side

DIN rail Manual override∗1


(L5) L1
holding screw
(For DIN (15) (Push-turn locking slotted type:
Press, then rotate it. )
rail mounting) (Light/surge voltage suppressor) 4(A) port side : Blue (For rubber seal)
: Grey (For metal seal) (Connector entry upward direction)
2(B) port side : Yellow

(8)
(DIN rail)
B A B A B A B A B A
(35)

14 A 14 A 14 A 14 A 14 A
70.6

128.8
115

(5.5)

96.7
(77.1)

74.9

12 B 12 B 12 B 12 B 12 B
5.5
39.6
8.8

3.9
(6)
(9.3)

2 x M2.6
(17.9)

(A, B port: Ø 12) 4 x M5 mounting hole 2 x 4-40 UNC


[4(A), 2(B) port: N (inch size)]
36.2 L2 1.5 (Fitting for the type with P/E
(5.3) (L4) ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3) Applicable connector: D-sub
(JIS-X-5101
MIL-C-24308 )
equivalent

∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10FW2-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 136.7 155.7 174.7 193.7 212.7 231.7 250.7 269.7 288.7 307.7 326.7 345.7 364.7 383.7 402.7 421.7 440.7 459.7 478.7 497.7 516.7 535.7 554.7
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 173 185.5 210.5 223 248 260.5 285.5 298 323 335.5 360.5 385.5 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5
L4 162.5 175 200 212.5 237.5 250 275 287.5 312.5 325 350 375 387.5 412.5 425 450 462.5 487.5 500 525 537.5 562.5 575
L5 20.5 17 20 17 20 16.5 19.5 16.5 19.5 16 19 22 19 22 18.5 21.5 18.5 21.5 18 21 18 21 17.5

51
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY3000 Series Connector Connecting Base Flat Ribbon Cable

C2
P U
SS5Y3-10 PG 12 - Stations D - C3, N1
C4, N3 (D)
PH B C6, N7
One-touch fitting
(Station 1)---(Station n) [4(A), 2(B) port]
Applicable tube O.D.: Ø 2
18.8
: Ø 3.2, Ø 1/8"
: Ø 4, Ø 5/32"
1 P 1 P
: Ø 6, Ø 1/4"
(75.4)

10.6
13.6

63.1
56.6
48.6

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

21.6
4 A4 A4 A4 A4 A
18

(Pitch)

(For DIN rail


7.5

mounting)
One-touch fitting 31.4 15.5 P = 10.5 (17.8)

11.8
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 8, Ø 5/16"
D side U side

(L5) L1 Manual override∗1

DIN rail holding screw (Push-turn locking slotted type:


Press, then rotate it. ) (Connector entry upward direction)
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
Light/surge : Grey (For metal seal)
DIN rail (8) Triangle mark
2(B) port side : Yellow
voltage suppressor

LOCK
B A B A B A B A B A
5.5

14 A 14 A 14 A 14 A 14 A 92.6
70.6

35
83

60.5

FREE
44.8
40.9
4.6

12 B 12 B 12 B 12 B 12 B
4.6
9.5

1.7
(4.9)

N7: 7.4 )

(Fitting for the type


3.6

with P/E ports on the Applicable connector:


(C6:

U and/or D sides) 26 pins MIL type with strain relief


19.6 L2 1.5 4 x M4 mounting hole (Conforming to MIL-C-83503)
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3

∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10P2-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.
∗ Only connectors are different for 10PG and 10PH. L1 to L5 dimensions are the same as 10P type.

10PG (20 pins) 10PH (10 pins)

Triangle mark Triangle mark


LOCK

LOCK
FREE

FREE

Applicable connector: Applicable connector:


20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 88.6 99.1 109.6 120.1 130.6 141.1 151.6 162.1 172.6 183.1 193.6 204.1 214.6 225.1 235.6 246.1 256.6 267.1 277.6 288.1 298.6 309.1 319.6
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 123 135.5 148 160.5 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 298 298 310.5 323 335.5 348 360.5
L4 112.5 125 137.5 150 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275 287.5 287.5 300 312.5 325 337.5 350
L5 20.5 21.5 22.5 23.5 18 19 20 21 22 23 18 19 20 21 22 23 23.5 18.5 19.5 20.5 21.5 22.5 23.5
52
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY5000 Series Connector Connecting Base Flat Ribbon Cable

P U C4, N3
SS5Y5-10 PG 12 - Stations D - C6, N7 (D) One-touch fitting
PH B C8, N9
[4(A), 2(B) port]
Applicable tube O.D.: Ø 4, Ø 5/32"
(Station 1)----------- (Station n) : Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
18.8
(75.4)

14.1
1 P 1 P

73.2
8.7
56.6

2 B2 B2 B2 B2 B
48.6

12.4
33.4

3/5 E 3/5 E

29.1
4 A4 A4 A4 A4 A

(For DIN rail


One-touch fitting

mounting)
7.5
(Pitch)

11.8
[1(P), 3/5(E) port] 35.9 18 (20.5)
P = 16
Applicable tube O.D.: Ø 10, Ø 3/8"

D side U side
(L5) Manual override∗1
L1
DIN rail holding screw
(For DIN rail mounting)
(8) (
Push-turn locking slotted type:
Press, then rotate it. ) (Connector entry upward direction)
Light/surge voltage suppressor 4(A) port side : Blue (For rubber seal)
DIN rail : Grey (For metal seal) Triangle mark
2(B) port side : Yellow

8
5.5

LOCK
BA BA BA BA BA
70.6

14 A 14 A 14 A 14 A 14 A
35
97.5

113.4

FREE
81.2

65.6
61.7
5.5

12 B 12 B 12 B 12 B 12 B
30.3
10.9

4 x M5 mounting hole
4.7
(5.9)
(8.3)

(Fitting for the type with P/E Applicable connector:


21.9 L2 1.5 26 pins MIL type with strain relief
ports on the U and/or D sides)
5.3 L4 (Conforming to MIL-C-83503)
(DIN rail mounting hole pitch: 12.5)
L3

10PG (20 pins) 10PH (10 pins)


∗1 Refer to page 178 for Triangle mark Triangle mark
dimensions of the external
pilot, silencer, elbow fittings,
and slide locking manual
override.
LOCK

∗ These figures show the


LOCK

“SS5Y5-10P2-05D-C8.”
∗ Refer to page 183 for
FREE

dimensions of A or B port
FREE

top-ported type.
∗ Only connectors are different
for 10PG and 10PH.
L1 to L5 dimensions are the
same as 10P type.

Applicable connector: Applicable connector:


20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 108.4 124.4 140.4 156.4 172.4 188.4 204.4 220.4 236.4 252.4 268.4 284.4 300.4 316.4 332.4 348.4 364.4 380.4 396.4 412.4 428.4 444.4 460.4
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 148 160.5 173 198 210.5 223 235.5 260.5 273 285.5 298 323 335.5 348 373 385.5 398 410.5 435.5 448 460.5 485.5 498
L4 137.5 150 162.5 187.5 200 212.5 225 250 262.5 275 287.5 312.5 325 337.5 362.5 375 387.5 400 425 437.5 450 475 487.5
L5 23 21 19.5 24 22 20.5 18.5 23 21.5 19.5 18 22.5 20.5 19 23.5 21.5 20 18 22.5 21 19 23.5 22
53
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY7000 Series Connector Connecting Base Flat Ribbon Cable

P U C6, N7
SS5Y7-10 PG D 1 - Stations DB - C8,
PH 2
N9
C10, N11 (D)
C12
One-touch fitting
One-touch fitting (Station 1) (Station n) [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: Ø 6, Ø 1/4"
Applicable tube O.D.: Ø 12, Ø 1/2" : Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
18.8

2
: Ø 12

82.7
1 P 1 P
(75.4)

2 B2 B2 B2 B2 B

56.6
48.6

14.2

3/5 E 3/5 E

11.1
8.7
35.2

31.6
4 A4 A4 A4 A4 A

(For DIN rail


(Pitch)

mounting)
(10)

(14.3)
(21.7)
39.5 20.5 P = 19

D side U side Manual override∗1

DIN rail holding screw


(L5) L1 (
Push-turn locking slotted type:
Press, then rotate it. ) (Connector entry upward direction)
(For DIN rail mounting) (8) (Light/surge voltage suppressor) 4(A) port side : Blue (For rubber seal)
: Grey (For metal seal)
2(B) port side : Yellow Triangle mark

(8)
(DIN rail)

LOCK
B A B A B A B A B A
(35)

14 A 14 A 14 A 14 A 14 A
70.6

128.8
115

FREE
(5.5)

96.7
(77.1)

79.5
44.2

12 B 12 B 12 B 12 B 12 B
5.5
8.8

3.9
(6)
(9.3)

Applicable connector:
(A, B port: Ø 12)
(17.9)

26 pins MIL type with strain relief


20.7 L2 1.5 4 x M5 mounting hole
(Conforming to MIL-C-83503)
(5.3) (L4) (Fitting for the type with P/E
(DIN rail mounting hole pitch: 12.5) ports on the U and/or D sides)
(L3)

10PG (20 pins) 10PH (10 pins)


Triangle mark Triangle mark ∗1 Refer to page 179 for dimensions
of the external pilot, silencer,
elbow fittings, and slide locking
manual override.
∗ These figures show the “SS5Y7-
10P2-05D-C8.”
LOCK

LOCK

∗ Refer to page 184 for dimensions


of A or B port top-ported type.
∗ Only connectors are different for
FREE

FREE

10PG and 10PH. L1 to L5


dimensions are the same as 10P
type.

Applicable connector: Applicable connector:


20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 121.2 140.2 159.2 178.2 197.2 216.2 235.2 254.2 273.2 292.2 311.2 330.2 349.2 368.2 387.2 406.2 425.2 444.2 463.2 482.2 501.2 520.2 539.2
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 160.5 173 198 210.5 235.5 248 273 285.5 310.5 323 348 360.5 385.5 398 423 435.5 460.5 485.5 498 523 535.5 560.5 573
L4 150 162.5 187.5 200 225 237.5 262.5 275 300 312.5 337.5 350 375 387.5 412.5 425 450 475 487.5 512.5 525 550 562.5
L5 22.5 19.5 22.5 19 22 19 22 18.5 21.5 18.5 21.5 18 21 18 21 17.5 20.5 23.5 20.5 23.5 20 23 20
54
Plug-in Connector Connecting Base
D-sub Connector Flat Ribbon Cable
Type 12
SY3000/5000/7000 Series
®

Top Ported
RoHS
How to Order Manifolds

Refer to pages 182 to 184


for the dimensions of
SS5Y 3 12 F 1 05 U
Type 12/Top-ported type.
q w e r t y u i
q Series e Connector entry direction
3 SY3000 1: Upward 2: Lateral ∗ The connector entry di-
5 SY5000 rection for connector type
7 SY7000 "FW" D-sub connector
<IP67> cannot be rotat-
w Connector type LOC
K
LOC
K
ed. If it is necessary to
F: D-sub connector <IP40> FW: D-sub connector <IP67> P: Flat ribbon cable FRE
E
FRE
E
change, order the con-
(25 pins) (25 pins) (26 pins) nector block assembly
(+page 227) separately.

r Valve stations
LOC
K
LOC
K
F/FW: D-sub connector (25 pins) P: Flat ribbon cable (26 pins)
FRE
E
FRE
E
Symbol Stations Note Symbol Stations Note
02 2 stations 02 2 stations
Double wiring∗1 Double wiring∗1



PG: Flat ribbon cable PH: Flat ribbon cable 12 12 stations 12 12 stations
(20 pins) (10 pins) 02 2 stations Specified layout∗2 02 2 stations Specified layout∗2



(Up to 24 solenoids (Up to 24 solenoids
24 24 stations available) 24 24 stations available)

LOC LOC
PG: Flat ribbon cable (20 pins) PH: Flat ribbon cable (10 pins)
K K
FRE FRE
Symbol Stations Note Symbol Stations Note
E E
02 2 stations 02 2 stations
Double wiring∗1 Double wiring∗1



09 9 stations 04 4 stations
t P, E port entry 02 2 stations Specified layout∗2 02 2 stations Specified layout∗2
U∗1 U side (2 to 10 stations) ∗1 y For type “S”, SUP/EXH block



(Up to 18 solenoids (Up to 8 solenoids
D∗1 D side (2 to 10 stations) assembly with a built-in silencer, 18 18 stations available) 08 8 stations available)
B Both sides (2 to 24 stations) choose U or D for P, E port entry.
∗1 Double wiring: 2-position single, double, 3-position, and 4-position
valves can be used on all manifold stations.
How to Order Manifold Assembly Use of a 2-position single solenoid will result in an unused control
signal. If this is not desired, order with a specified layout.
∗2 Specified layout: Indicate the wiring specifications on the manifold
Example (SS5Y3-12F1-) specification sheet. (Note that 2-position double, 3-position, and
2-position double (24 VDC) 4-position valves cannot be used where single wiring has been
2-position single (24 VDC) SY3230-5U1-C6 (1 set) specified.)
SY3130-5U1-C6 (3 sets) ∗ This also includes the number of the blanking plate assembly.
3-position closed
centre (24 VDC)
SY3330-5U1-C6 (1 set) y SUP/EXH block assembly i Mounting
— Internal pilot — Direct mounting
Internal pilot, D DIN rail mounting (With DIN rail)
S Built-in silencer D0 DIN rail mounting (Without DIN rail)
LOC
R External pilot D3 For 3 stations Specify a length

K

ide ∗ The P and E ports are only available longer than that of
FRE
E Us on the U and D sides for the built-in D24 For 24 stations the standard rail.
s

silencer type. 3/5(E) port is plugged.


n

∗ Refer to page 319 for the


tio
ta

The silencer exhaust port is located on


S

the opposite side of the P and E port fixation of DIN rail mounting
3

Manifold base
type manifold.
2

(5 stations) entry. (Example: When the P and E


1

ide port entry is on the D side, the silencer


SS5Y3-12F1-05D Ds
exhaust port is on the U side.)
SS5Y3-12F1-05D ······
∗SY3130-5U1-C6 ········
1 set (Type 12 5-station manifold base part no.)
3 sets (2-position single part no.) u P, E port size (One-touch fittings)
∗SY3230-5U1-C6 ········ 1 set (2-position double part no.) Symbol SY3000 SY5000 SY7000
∗SY3330-5U1-C6 ········ 1 set (3-position closed centre part no.)
— Ø8 Ø 10 Ø 12
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc. N Ø 5/16" Ø 3/8" Ø 1/2"
• For the valve arrangement, the valve closest to the D side is considered the 1st station. ∗ For N, sizes are in inches.
• Under the manifold part number, state the valves to be mounted in order
starting with the 1st station as shown in the figure above. If the
arrangement becomes too complicated, specify the details on a manifold
specification sheet.

55
Plug-in Connector Connecting Base SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported

q Series y Pilot valve option !1 A, B port size


3 SY3000 — Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K∗1 High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗1 Only the metal seal type is available for the 01 1/8 SY5000
w Type of actuation high pressure type. 02 1/4 SY7000
1
u Coil type
Single One-touch fitting (Metric)
2-position
2 Double Symbol A, B port SY3000 SY5000 SY7000
3 Closed centre — Standard
C2 Ø2  — —
4 3-position Exhaust centre T With power saving circuit (Continuous duty type)
C3 Ø 3.2  — —
5 Pressure centre ∗ Be sure to select the power saving circuit C4 Ø4   —
A∗1 type if the valve is to be continuously
4-position N.C./N.C. C6 Ø6   
energised for long periods of time.
B∗1 dual N.O./N.O. C8 Ø8 —  
∗ Be careful of the energising time when the
C∗1 3-port N.C./N.O. power saving circuit is selected. Refer to page C10 Ø 10 — — 
∗1 Only the rubber seal type is available for the 316 for details. C12 Ø 12 — — 
4-position dual 3-port valve.
i Rated voltage
One-touch fitting (Inch)
Symbol A, B port SY3000 SY5000 SY7000
5 24 VDC N1 Ø 1/8"  — —
e Seal type 6 12 VDC
N3 Ø 5/32"   —
0 Rubber seal N7 Ø 1/4"   
1 Metal seal o Light/surge voltage suppressor N9 Ø 5/16" —  
and common specification N11 Ø 3/8" — — 
Surge voltage Common
r Pilot type Symbol With light
suppressor specification
!2 Thread type
— Internal pilot — — —
— Rc
R External pilot R — Non-polar
F G
U 
N NPT
S — Positive
 T NPTF
t Back pressure check valve Z
NS —
 common
Negative
∗ Only — is available for M5.
(Built-in valve type)
NZ  common
— None
∗ For the non-polar type, be careful of surge
H Built-in
voltage intrusion. !3 Type of mounting screw
∗ Only the rubber seal type is available. A Refer to page 317 for details. — Round head combination screw
manifold installed type is available if a back ∗ Only “Z” and “NZ” types are available with a B Hexagon socket head cap screw
pressure check valve with a metal seal is power saving circuit. K Round head combination screw (Drop prevention type)
required. Refer to page 236 for ordering
examples. However, it is not recommended H Hexagon socket head cap screw (Drop prevention type)
∗ For “K” and “H,” the valve body cover has a
to use the built-in valve type and the manifold
installed type at the same time because it will !0 Manual override drop prevention construction to stop the
reduce the flow. —: D: mounting screws from falling out when the
∗ The built-in valve type back pressure check Non-locking Push-turn valve is removed for maintenance, etc.
valve is not available for the 3-position type push type locking ∗ When ordering a valve individually, the
or the SY7000. slotted base gasket is not included.
Since the base gasket is attached to the
type
manifold, please order the base gasket
separately if it is needed for maintenance.
Refer to page 222 for base gasket and
mounting screw part numbers.
E: F: ∗ “B” and “H” cannot be selected for the
Push-turn Slide locking individual SUP/EXH spacer assembly or
locking lever type interface regulator.
type

∗ Refer to page 36 for the safety slide locking


manual override.

Protective class
class # (Mark: )
56
SY3000/5000/7000 Series

Electrical Wiring Specifications Cable Assembly


015 015
D-sub connector
AXT100-DS25- 030 (N) [IP40] SY30M-DS25- 030 (N) [IP67]
If alignment is not specified, 050 050
the internal wiring will be —: Metric —: Metric
double wiring (connected to N: Inch N: Inch
1 SOL. a and SOL. b) Socket side Connector
14 2
15 regardless of number of 14 25 JBZ-25S-3 made by
3
16 4 stations, valve types, and Terminal no. J.S.T. Mfg. Co.,Ltd.

16
17 5
18 option types. 14…………25
6 Socket side
19 7 1 13
20 8 47.04

22
21 9
22 Connector terminal no. Terminal no.
10 Cable
23 11
24 0.3 mm2 x 25 cores 1…………13
12 O.D. Ø 1.4 47.04
25 13
Approx. Ø 10 Cable
0.3 mm2 x 25 cores
O.D. Ø 1.4
Terminal no. Polarity Seal (Length)
015
SOL.a
1 (−) (+) Approx. Ø 8
Molded cover
L

Station 1 SOL.b
14 (−) (+)
SOL.a 2 x M2.6 x 0.45
2 (−) (+)
Station 2 SOL.b or
44

15 (−) (+) 2 x 4 − 40 UNC


SOL.a
3 (−) (+)
Station 3 SOL.b Connector JBZ-25S-3
16 (−) (+) Seal (Length)
8

made by J.S.T. Mfg.


SOL.a
4 (−) (+) Co.,Ltd. 015
Station 4 SOL.b
(2.4)

17 (−) (+) 55
SOL.a Connector hood
5 (−) (+)

L
Station 5 SOL.b
18 (−) (+)
SOL.a
6 (−) (+)
Station 6 SOL.b
19 (−) (+)
SOL.a 2 x M2.6 x 0.45

(86.5)
7 (−) (+) or
Station 7 SOL.b
20 (−) (+)
Connector Manufacturer’s Example
2 x 4 − 40 UNC
SOL.a
8 (−) (+) • Fujitsu Limited
Station 8 SOL.b
21 (−) (+) • Japan Aviation Electronics Industry, Limited
SOL.a
8.7
9 (−) (+) • J.S.T. Mfg. Co., Ltd.
Station 9 SOL.b
22 (−) (+) • HIROSE ELECTRIC CO., LTD.
SOL.a
10 (−) (+)
Station 10 SOL.b
23 (−) (+)
SOL.a D-sub connector cable assembly [IP40] D-sub connector cable assembly [IP67]
11 (−) (+)
Station 11 SOL.b
24 (−) (+) Cable Cable
SOL.a
(−) (+) Assembly part no. Note Assembly part no. Note
12 length (L) length (L)
Station 12 SOL.b
25 (−) (+) 1.5 m SY30M-DS25-015
1.5 m AXT100-DS25-015
Cable Cable
3m AXT100-DS25-030 3m SY30M-DS25-030
COM.
(+) (−) 0.3 mm2 x 25 cores 0.3 mm2 x 25 cores
13 5m AXT100-DS25-050 5m SY30M-DS25-050
Positive Negative
common common ∗ When using a standard commercial ∗ Be sure to use the connector cable assembly in
connector, use a 25-pin type female the table, to satisfy enclosure IP67.
∗ When using a valve with no polarity, either positive connector conforming to MIL-C-24308. ∗ Cannot be used for movable wiring
common or negative common can be used. ∗ Cannot be used for movable wiring
∗ Lengths other than the above are also
Terminal Lead wire Dot available. Please contact SMC for details. Electrical characteristics
no. colour marking
Item Property
1 Black None
D-sub connector cable assembly terminal numbers Conductor resistance 65 or
2 Brown None 액/km, 20 °C less
3 Red None Terminal
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Voltage limit
4 Orange None no. 1000
V, 1 minute, AC
White
White

White
Brown

Brown
Orange
Yellow

Yellow
Orange
Yellow

Orange
Purple

Purple

5 Yellow None
Black

Black
Grey

Grey

Grey
Blue

Blue
Pink

Pink

Pink

Lead wire
Red

Red

Insulation resistance 5 or
6 Pink None colour M액/km, 20 °C more
7 Blue None
∗ The minimum bending
White

White

White
White

White
Black
Black

Black
Black

Black
None
None
None
None
None
None
None

None
None

None

Dot
Red
Red
Red

Red
Red

8 Purple White
marking radius of the D-sub
9 Grey Black connector cable is 20 mm.
10 White Black
11 White Red
12 Yellow Red
13 Orange Red Specified Layout
14 Yellow Black (25 pins)
15 Pink Black
16 Blue White A mixture of single and double
17 Purple None 1 wiring can be specified on the
14 2
18 Grey None 15 3
manifold specification sheet. The
16
19 Orange Black 17
4 maximum number of stations is
5
20 Red White 18 6 determined according to the number
19
21 Brown White 20
7 of solenoids. The total number of
8
22 Pink Red 21 9 solenoids should be 24 or less. 1
22 10
23 Grey Red 23 solenoid is required for the
11
24 Black White 24 12 2-position single, and 2 solenoids for
25 13
25 White None the 2-position double, 3-position,
and 4-position.
∗ Connector made in conformity with MIL-C-24308
COM.
57
Plug-in Connector Connecting Base SY3000/5000/7000 Series

Electrical Wiring Specifications Connector Cable


D-sub connector GVVZS3000-21A- [IP40]
D-sub connector/cable
If alignment is not specified, the internal wiring is double
wiring (connected to SOL. a and SOL. b) regardless of Cable
1 Assembly part no. Note
14 number of stations, valve and option types. length (L)
2
15 3 1m GVVZS3000-21A-160 60°angled
16 4
17 3m GVVZS3000-21A-260 60°angled
5
18 6 5m GVVZS3000-21A-360 60°angled
19 7
20 8m GVVZS3000-21A-460 60°angled
8
21 9 3m GVVZS3000-21A-2 Standard
Connector terminal no.
22 10 5m GVVZS3000-21A-3 Standard
23 11
24 8m GVVZS3000-21A-4 Standard
12
25 13
Shielded cable
Cable
Assembly part no. Note
Lead wire no. Polarity length (L)
SOL. a Terminal Lead wire Dot 1m GVVZS3000-21A-1S Shieled
1 (−) (+) no. colour marking
Station 1 SOL. b 3m GVVZS3000-21A-2S Shieled
14 (−) (+)
SOL. a 1 Black None 5m GVVZS3000-21A-3S Shieled
2 (−) (+)
Station 2 SOL. b 15 8m GVVZS3000-21A-4S Shieled
(−) (+) 2 Brown None
SOL. a 20 m GVVZS3000-21A-5S Made to order
3 (−) (+) 3 Red None
Station 3 SOL. b 16 (−) (+) 4 Orange None
SOL. a 4 (−) (+)
Station 4 5 Yellow None
SOL. b 17 (−) (+)
SOL. a 5 (−) (+)
6 Pink None 60° angled Standard
Station 5 SOL. b 18 7 Blue None
(−) (+) 14 - - - - - -25
SOL. a (−) (+) 8 Purple White
6

20
L

Station 6 SOL. b 19 9 Grey Black


(−) (+)
SOL. a 10 White Black 1- - - - - - - -13
7 (−) (+)
Station 7 SOL. b

53.5
(−) (+) 11 White Red

2- M2.6
20
SOL. a
8 (−) (+) 12 Yellow Red
Station 8 SOL. b
21 (−) (+) 13 Orange Red
SOL. a
9 (−) (+) 14 Yellow Black
Station 9 SOL. b 22 (−) (+) 25 L
SOL. a 15 Pink Black
10 (−) (+) 41 41
Station 10 SOL. b 23 16 Yellow White
(−) (+)
15.2

SOL. a 17 White None


11 (−) (+)
Station 11 SOL. b 24 18 Grey None
(−) (+)
SOL. a 19 Orange Black 53
12 (−) (+)
Station 12 SOL. b 25 (−) (+) 20 Red White
Electrical characteristics
21 Brown White
COM. Item Property
13 (+) (−) 22 Pink Red
Conductor resistance 액/km, 20 °C Max. 57
Positive Negative 23 Grey Red
common common
Voltage limit V, 5 minute, AC 1500
24 Black White
Insulation resistance M액/km, 20 °C 20
∗ When using a valve with no polarity, either positive 25 White None
common or negative common can be used.

Standard
D-Sub connector cable assembly (option)
015
AXT100-DS25- 030 (According to MIL-C24308)
050

∗ Please contact SMC for details.

58
SY3000/5000/7000 Series

Electrical Wiring Specifications


Flat ribbon cable connector
If alignment is not specified, the internal
wiring will be double wiring (connected to
26 25
24 23
SOL. a and SOL. b) regardless of number
22 21 of stations, valve types, and option types.
20 19
18 17
16 15
14 13
12 11 Connector terminal no.
10 9
8 7
Triangle mark indicator position
6 5
4 3
2 1

P: Flat ribbon cable (26 pins) PG: Flat ribbon cable (20 pins)
<Double wiring> <Double wiring>
Terminal no. Polarity Terminal no. Polarity
SOL.a 1 (−) (+) SOL.a 1 (−) (+)
Station 1 SOL.b Station 1 SOL.b
2 (−) (+) 2 (−) (+)
SOL.a 3 (−) (+) SOL.a 3 (−) (+)
Station 2 SOL.b Station 2 SOL.b
4 (−) (+) 4 (−) (+)
SOL.a 5 (−) (+) SOL.a 5 (−) (+)
Station 3 SOL.b Station 3 SOL.b
6 (−) (+) 6 (−) (+)
SOL.a 7 (−) (+) SOL.a 7 (−) (+)
Station 4 SOL.b Station 4 SOL.b
8 (−) (+) 8 (−) (+)
SOL.a 9 (−) (+) SOL.a 9 (−) (+)
Station 5 SOL.b Station 5 SOL.b
10 (−) (+) 10 (−) (+)
SOL.a 11 (−) (+) SOL.a 11 (−) (+)
Station 6 SOL.b Station 6 SOL.b
12 (−) (+) 12 (−) (+)
SOL.a 13 (−) (+) SOL.a 13 (−) (+)
Station 7 SOL.b Station 7 SOL.b
14 (−) (+) 14 (−) (+)
SOL.a 15 (−) (+) SOL.a 15 (−) (+)
Station 8 SOL.b Station 8 SOL.b
16 (−) (+) 16 (−) (+)
SOL.a 17 (−) (+) SOL.a 17 (−) (+)
Station 9 SOL.b Station 9 SOL.b
18 (−) (+) 18 (−) (+)
SOL.a 19 (−) (+) COM.
Station 10 SOL.b 19 (+) (−)
20 (−) (+) COM.
SOL.a 20 (+) (−)
21 (−) (+) Positive Negative
Station 11 SOL.b 22 (−) (+) common common
SOL.a 23 (−) (+)
Station 12 SOL.b 24 (−) (+)
COM.
25 (+) (−)
COM.
26 (+) (−)
Positive Negative
common common

PH: Flat ribbon cable (10 pins)


<Double wiring>
Terminal no. Polarity
SOL.a 1 (−) (+)
Station 1 SOL.b 2 (−) (+)
SOL.a 3 (−) (+)
Station 2 SOL.b 4 (−) (+)
SOL.a 5 (−) (+)
Station 3 SOL.b 6 (−) (+)
SOL.a 7 (−) (+)
Station 4 SOL.b 8 (−) (+)
COM.
9 (+) (−)
COM.
10 (+) (−)
Positive Negative
common common

∗ When using a valve with no polarity,


either positive common or negative
common can be used.

59
Plug-in Connector Connecting Base SY3000/5000/7000 Series

Flat Ribbon Cable Assembly


10 1
AXT100-FC 20 - 2
26 3

6 Terminal no. 28AWG


Red

17.2 (10 pins)


30 (20 pins)
37.5 (26 pins)

1
26

25
(15.6)
L

Flat ribbon cable connector assembly


Cable Assembly part no. Connector Manufacturer’s Example
length (L) 26 pins 20 pins 10 pins
• HIROSE ELECTRIC CO., LTD.
1.5 m AXT100-FC26-1 AXT100-FC20-1 AXT100-FC10-1 • 3M Japan Limited
3m AXT100-FC26-2 AXT100-FC20-2 AXT100-FC10-2 • Fujitsu Limited
5m AXT100-FC26-3 AXT100-FC20-3 AXT100-FC10-3 • Japan Aviation Electronics Industry, Limited
• J.S.T. Mfg. Co., Ltd.
∗ When using a standard commercial connector, use a 26-pin, 20-pin, or 10-pin
• Oki Electric Cable Co., Ltd.
type connector conforming to MIL-C-83503 with strain relief.
∗ Cannot be used for movable wiring
∗ Lengths other than the above are also available. Please contact SMC for details.

Specified Layout

COM. COM.

26 25
24 23 COM. COM.
22 21
20 19 20 19
18 17 18 17
16 15 16 15
14 13 14 13 COM. COM.
12 11 12 11
10 9 10 9 10 9
8 7 8 7 8 7
6 5 6 5 6 5
4 3 4 3 4 3
2 1 2 1 2 1

(P: 26 pins) (PG: 20 pins) (PH: 10 pins)

A mixture of single and double wiring can be specified on the manifold specification. The maximum number of stations is determined according to the number of solenoids.
The total number of solenoids should be 2 4 or less for P, 18 or less for PG, and 8 or less for PH. 1 solenoid is required for the 2 -position single, and 2 solenoids for the
2-position double, 3-position, and 4-position.

60
Type 10
Plug-in Connector Connecting Base
Side Ported Terminal Block Box (Spring Type)
Type 11
Bottom Ported
SY3000/5000/7000 Series ®

RoHS
How to Order Manifolds

Refer to pages 180 (SY5000) and SS5Y 3 10 TC 05 D C6


181 (SY7000) for the dimensions
of Type 11/Bottom-ported type.
q w e r t y u
q Series e Valve stations u Mounting and Option DIN Rail Option
3 SY3000 TC: Spring type terminal block box Symbol Mounting Option — DIN rail mounting (with DIN rail)
5 SY5000 Symbol Stations Note — Direct
None 0 DIN rail mounting (without DIN rail)
7 SY7000 02 2 stations AA Name plate (with station number) 3 For 3 stations Specify a length
mounting

···

···
Double wiring ∗1 BA Name plate (without station number) longer than that of
···

···

w Type 16 16 stations D
DIN rail
Without name plate
A mounting Name plate (with station number)
24 For 24 stations the standard rail.
10 Side ported 02 2 stations Specified layout ∗2
Bottom ported ∗1
B Name plate (without station number)
···

···

11 (Up to 32 solenoids
24 24 stations available) ∗ Enter the number of stations inside . (Refer to “DIN Rail Option” above.)
∗1 The SY5000 manifold base is used for
∗ Only direct mounting is available for the type 11 bottom-ported type.
the bottom-ported SY3000. When order- ∗1 Double wiring: 2-position sin-
ing, refer to the “Plug-in Manifold Mixed
Mounting Type” (from page 185).
gle, double, 3-position, and
4-position valves can be used
y A, B port size (Metric/One-touch fitting)
on all manifold stations. Type 10/Side ported Type 11/Bottom ported
Symbol A, B port
r P, E port entry Use of a 2-position single so-
C2 Ø2
SY3000 SY5000 SY7000 SY5000 SY7000
 — — — —
lenoid will result in an unused
U U side (2 to 10 stations) C3 Ø 3.2  — — — —
control signal. If this is not de-
D D side (2 to 10 stations) C4 Ø4   —  —
sired, order with a specified
Straight

B Both sides (2 to 24 stations) C6 Ø6     


layout.
∗2 Specified layout: Indicate the C8 Ø8 —    
t SUP/EXH block assembly wiring specifications with the C10 Ø 10 — —  — 
— Internal pilot manifold specification sheet. C12 Ø 12 — —  — 
S Internal pilot, Built-in silencer (Note that 2-position double, CM∗1 Straight port, mixed sizes     
R External pilot 3-position, and 4-position L4 Ø4   — — —
  
Upward

∗ 3/5(E) port is plugged for the built-in valves cannot be used where L6 Ø6 — —
silencer type. single wiring has been speci- L8 Ø8 —   — —
∗ When the built-in silencer type is used, fied.) L10 Ø 10 — —  — —
∗ This also includes the number L12 
Elbow ∗2

keep the exhaust port from coming into Ø 12 — — — —


direct contact with water or other liquids. of the blanking plate assembly. B4 Ø4   — — —
Downward

B6 Ø6    — —
How to Order Manifold Assembly B8 Ø8 —   — —
B10 Ø 10 — —  — —
B12 Ø 12 — —  — —
Example (SS5Y3-10TC-)
LM∗1 Elbow port, mixed sizes (Including
upward and downward piping)    — —
2-position double (24 VDC) 3-position closed centre (24 VDC) P, E port size (One-touch fittings) Ø8 Ø 10 Ø 12 Ø 10 Ø 12
SY3200-5U1 (1 set) SY3300-5U1 (1 set)
A, B port size (Inch/One-touch fitting)
2-position single (24 VDC) Type 10/Side ported Type 11/Bottom ported
SY3100-5U1 (3 sets)
Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000
N1 Ø 1/8"  — — — —
N3 Ø 5/32"   —  —
Straight

N7 Ø 1/4"     
N9 Ø 5/16" —    
N11 Ø 3/8" — —  — 
e
sid

CM∗1 Straight port, mixed sizes     


U
s
ion


at

LN3 Ø 5/32" — — — —
St

Downward Upward

LN7  
3

Ø 1/4" — — —
2
1

LN9 Ø 5/16" —  — — —
e
sid

Manifold base (5 stations)


D

LN11 
Elbow ∗2

SS5Y3-10TC-05D-C6
Ø 3/8" — — — —
BN3 Ø 5/32"  — — — —
SS5Y3-10TC-05D-C6 ·····1 set (Type 10 5-station manifold base part no.) BN7 Ø 1/4"   — — —
∗ SY3100-5U1 ·················· 3 sets (2-position single part no.) BN9 Ø 5/16" —  — — —
∗ SY3200-5U1 ·················· 1 set (2-position double part no.) BN11 Ø 3/8" — —  — —
∗ SY3300-5U1 ·················· 1 set (3-position closed centre part no.) LM∗1 Elbow port, mixed sizes (Including
   — —
upward and downward piping)
The asterisk denotes the symbol for the assembly. P, E port size (One-touch fittings) Ø 5/16" Ø 3/8" Ø 1/2" Ø 3/8" Ø 1/2"
Prefix it to the part numbers of the valve, etc.
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
• For the valve arrangement, the valve closest to the D side is considered the 1st station. The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,”
• Under the manifold part number, state the valves to be mounted in order indicate it on the manifold specification sheet for the P, E port fitting direction.
starting with the 1st station as shown in the figure above. If the arrangement ∗2 To avoid interference with the body or piping, select a downward elbow port
becomes too complicated, specify the details on a manifold specification sheet.
when mounting the optional spacer assembly.
61
Plug-in Connector Connecting Base SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

q Series y Pilot valve option !0 Manual override


3 SY3000 — Standard (0.7 MPa) —: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K∗1 High pressure type (1.0 MPa) push type locking
∗1 Only the metal seal type is available for the slotted
high pressure type. type

w Type of actuation
1
2-position
Single u Coil type E: F:
2 Double — Standard Push-turn Slide locking
3 Closed centre T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit lever
5 Pressure centre type if the valve is to be continuously type
A∗1 N.C./N.C. energised for long periods of time.
4-position ∗ Be careful of the energising time when the
B∗1 dual 3-port
N.O./N.O.
C∗1 N.C./N.O. power saving circuit is selected. Refer to
∗ Refer to page 36 for the safety slide locking
page 316 for details.
∗1 Only the rubber seal type is available for the manual override.
4-position dual 3-port valve.
i Rated voltage
e Seal type
5
6
24 VDC
12 VDC
!1 Type of mounting screw
— Round head combination screw
0 Rubber seal
B Hexagon socket head cap screw
1 Metal seal
K Round head combination screw (Drop prevention type)
o Light/surge voltage suppressor H Hexagon socket head cap screw (Drop prevention type)
and common specification ∗ For “K” and “H,” the valve body cover has a
r Pilot type Symbol With light
Surge voltage Common drop prevention construction to stop the
mounting screws from falling out when the
— Internal pilot suppressor specification
valve is removed for maintenance, etc.
R External pilot — — —
∗ When ordering a valve individually, the
R — Non-polar base gasket is not included.
U  Since the base gasket is attached to the
S — Positive manifold, please order the base gasket
t Back pressure check valve Z 

common separately if it is needed for maintenance.
(Built-in valve type) NS — Refer to page 222 for base gasket and
Negative
mounting screw part numbers.
— None NZ  common
∗ “B” and “H” cannot be selected for the
H Built-in ∗ For the non-polar type, be careful of surge individual SUP/EXH spacer assembly,
∗ Only the rubber seal type is available. A voltage intrusion. interface regulator, or double check spacer
manifold installed type is available if a back Refer to page 317 for details. assembly with residual pressure release
pressure check valve with a metal seal is ∗ Only “Z” and “NZ” types are available with a valve.
required. Refer to page 236 for ordering power saving circuit.
examples. However, it is not recommended
to use the built-in valve type and the manifold
installed type at the same time because it will
reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.

Protective class
class # (Mark: )
62
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY3000 Series Connector Connecting Base Terminal Block Box

U C2
SS5Y3-10TC- Stations DB - C3, N1
C4, N3 (D)
C6, N7

(Station 1) (Station n)

One-touch fitting Manifold block internal wiring specifications


[1(P), 3/5(E) port] —: Double wiring
Applicable tubing O.D. C8: Ø 8 (SMC) S : Single wiring
N9: Ø 5/16" (SMC)

manual override)
(Slide locking
1 P 1 P

21.6

68.8
10.6

13.6
71

63.1
56.6
3/5 S 3/5
E 2 B2 B2 B2 B2 B E
40.2

(11.8)
31.5

4 A4 A4 A4 A4 A

(7.5)
18

16.5 (Pitch) (17.8)


2 x M20 x 1.5 thread depth 13 P = 10.5
(Conduit port) 15.5 One-touch fitting
85.8 [4(A), 2(B) port]
Applicable tubing O.D. C2: Ø 2 (SMC)
C3: Ø 3.2 (SMC)
C4: Ø 4 (SMC)
C6: Ø 6 (SMC)
N1: Ø 1/8" (SMC)
N3: Ø 5/32" (SMC)
N7: Ø 1/4" (SMC)

D side U side

(L5) L1 (Light/surge voltage suppressor)

Manual override
DIN rail holding screw
(For DIN rail mounting) (
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
(DIN rail)
: Grey (For metal seal)
(8) 2(B) port side: Yellow Plug
(5)

(5.5)
(35)

B A B A B A B A
102.6

92.6

14 A 14 A 14 A 14 A
83
60.5
(40.9)

12 B 12 B 12 B 12 B
4.6
1.7
5

4.6
(N7: 7.4)
(4.9)

C6: 3.6

4 x M4 Mounting hole
Silencer (Exhaust port)
(Recommended tightening torque: 1.4 N·m)
(Built-in silencer specification)
(Fitting for the type with P/E ports on
74 L2 1.5 the U or both sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 143 153.5 164 174.5 185 195.5 206 216.5 227 237.5 248 258.5 269 279.5 290 300.5 311 321.5 332 342.5 353 363.5 374
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 173 185.5 198 210.5 223 235.5 235.5 248 260.5 273 285.5 298 298 310.5 323 335.5 348 360.5 360.5 373 385.5 398 410.5
L4 162.5 175 187.5 200 212.5 225 225 237.5 250 262.5 275 287.5 287.5 300 312.5 325 337.5 350 350 362.5 375 387.5 400
L5 17.5 18.5 19.5 20.5 21.5 22.5 17 18 19 20 21 22 17 18 19 20 21 22 16.5 17.5 18.5 19.5 20.5
63
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY5000 Series Connector Connecting Base Terminal Block Box

U C4, N3
SS5Y5-10TC- Stations DB - C6, N7 (D)
C8, N9

(Station 1) (Station n)

One-touch fitting Manifold block internal wiring specifications


[1(P), 3/5(E) port] —: Double wiring
Applicable tubing O.D. C10: Ø 10 (SMC) S : Single wiring
N11: Ø 3/8" (SMC)

manual override)
(Slide locking
12.4

78.9
1 P 1 P

14.1

73.2
S

8.7
71

2 B2 B2 B2 B2 B

56.6
3/5

(11.8)
33.4

3/5 E E
31.5

29.1

(7.5)
4 A4 A4 A4 A4 A

87.5 18 (20.5)
(Pitch)
16.5 P = 16 One-touch fitting
[4(A), 2(B) port]
Applicable tubing O.D. C4: Ø 4 (SMC)
2 x M20 x 1.5 thread depth 13
C6: Ø 6 (SMC)
(Conduit port) C8: Ø 8 (SMC)
N3: Ø 5/32" (SMC)
N7: Ø 1/4" (SMC)
N9: Ø 5/16" (SMC)

D side U side
DIN rail holding screw Manual override

(L5)
(For DIN rail mounting)
L1 (
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
(DIN rail) : Grey (For metal seal) Plug
(5)

(Light/surge voltage suppressor) (8) 2(B) port side: Yellow


(5.5)

B A B A B A B A
14 A 14 A 14 A 14 A
118.4

113.4
97.5
81.2
(61.7)
(35)

10.9
5.5

12 B 12 B 12 B 12 B
4.7
(5.9)
(8.3)

4 x M5 Mounting hole
73.5 L2 1.5 (Recommended tightening torque: 2.9 N·m)
(5.3) (L4) (Fitting for the type with P/E ports on
the U or both sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

Silencer (Exhaust port)


(Built-in silencer specification)

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432 448 464 480 496 512
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 198 210.5 223 248 260.5 273 285.5 310.5 323 335.5 348 373 385.5 398 423 435.5 448 460.5 485.5 498 510.5 535.5 548
L4 187.5 200 212.5 237.5 250 262.5 275 300 312.5 325 337.5 362.5 375 387.5 412.5 425 437.5 450 475 487.5 500 525 537.5
L5 21.5 19.5 18 22.5 20.5 19 17 21.5 20 18 16.5 21 19 17.5 22 20 18.5 16.5 21 19.5 17.5 22 20.5
64
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY7000 Series Connector Connecting Base Terminal Block Box

U C6, N7
SS5Y7-10TC- Stations DB - C8, N9
C10, N11 (D)
C12

(Station 1) (Station n) One-touch fitting


[4(A), 2(B) port]
Applicable tubing O.D. C6 : Ø 6 (SMC)
Manifold block internal wiring specifications C8 : Ø 8 (SMC)
—: Double wiring C10: Ø 10 (SMC)
S : Single wiring C12: Ø 12 (SMC)
N7 : Ø 1/4" (SMC)
One-touch fitting N9 : Ø 5/16" (SMC)
[1(P), 3/5(E) port] N11: Ø 3/8" (SMC)
Applicable tubing O.D. C12: Ø 12 (SMC)
N13: Ø 1/2" (SMC)

manual override)
2

(Slide locking
14.2

85.8
82.7
1 P 1 P

11.1
S
2 B2 B2 B2 B2 B
71

56.6
3/5 E 3/5 E
35.2

8.7
31.5

31.6
4 A4 A4 A4 A4 A

(10)

(14.3)
16.5 (Pitch)
92.5 P = 19 (21.7)
20.5

2 x M20 x 1.5 thread depth 13


(Conduit port)

DIN rail holding screw


D side U side
(For DIN rail mounting)
(Light/surge voltage suppressor)
(L5) L1 Manual override

(
Push-turn locking slotted type:
Press, then rotate it. )
Silencer (Exhaust port) 4(A) port side: Blue (For rubber seal)
(Built-in silencer specification) (8) : Grey (For metal seal) Plug
2(B) port side: Yellow
(5)

B A B A B A B A
14 A 14 A 14 A 14 A
133.8

128.8
115
(5.5)
(35)

96.7
(77.1)

12 B 12 B 12 B 12 B
8.8
3.9
5.5
(6)

(DIN rail)
(N13: 20.4)

(17.9)
(9.3)

4 x M5 Mounting hole
(Recommended tightening torque: 2.9 N·m)
73.7 L2 1.5 (Fitting for the type with P/E ports on
(5.3) (L4) the U or both sides)
(DIN rail mounting hole pitch: 12.5)
(L3) (A, B port: Ø 12)

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 174.2 193.2 212.2 231.2 250.2 269.2 288.2 307.2 326.2 345.2 364.2 383.2 402.2 421.2 440.2 459.2 478.2 497.2 516.2 535.2 554.2 573.2 592.2
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 210.5 223 248 260.5 285.5 298 323 335.5 360.5 373 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5 610.5 623
L4 200 212.5 237.5 250 275 287.5 312.5 325 350 362.5 387.5 412.5 425 450 462.5 487.5 500 525 537.5 562.5 575 600 612.5
L5 20.5 17 20 17 20 16.5 19.5 16.5 19.5 16 19 22 19 22 18.5 21.5 18.5 21.5 18 21 18 21 17.5
65
Plug-in Connector Connecting Base
Terminal Block Box (Spring Type)

SY3000/5000/7000 Series ®

RoHS
How to Order Manifolds

Refer to pages 182 to 184


for the dimensions of SS5Y 3 12 TC 05 D
Type 12/Top-ported type.

q w e r t y u
q Series e Valve stations r P, E port entry
3 SY3000 TC: Spring type terminal block box U U side (2 to 10 stations)
5 SY5000 Symbol Stations Note D D side (2 to 10 stations)
7 SY7000 02 2 stations B Both sides (2 to 24 stations)
Double wiring ∗1
···

···

16 16 stations
02 2 stations
Specified layout ∗2
w Type t SUP/EXH block assembly
···

···

(Up to 32 solenoids available)


12 Top ported 24 24 stations — Internal pilot
∗1 Double wiring: 2-position single, double, 3-posi- S Internal pilot, Built-in silencer
tion, and 4-position valves can be used on all R External pilot
manifold stations.
∗ The P and E ports are only available on the
Use of a 2-position single solenoid will result in
U and D sides for the built-in silencer type.
an unused control signal. If this is not desired,
3/5(E) port is plugged. The silencer exhaust
order with a specified layout.
port is located on the opposite side of the P
∗2 Specified layout: Indicate the wiring specifica-
and E port entry. (Example: When the P and
tions with the manifold specification sheet.
E port entry is on the D side, the silencer
(Note that 2-position double, 3-position, and
exhaust port is on the U side.)
4-position valves cannot be used where single
∗ When the built-in silencer type is used, keep
wiring has been specified.)
the exhaust port from coming into direct
∗ This also includes the number of the blanking
contact with water or other liquids.
plate assembly.
How to Order Manifold Assembly

Example (SS5Y3-12TC-)
y P, E port size
(One-touch fittings)
2-position double (24 VDC) Symbol SY3000 SY5000 SY7000
3-position closed centre (24 VDC)
SY3230-5U1-C6 (1 set) — Ø8 Ø 10 Ø 12
SY3330-5U1-C6 (1 set)
2-position single (24 VDC) N Ø 5/16" Ø 3/8" Ø 1/2"
SY3130-5U1-C6 (3 sets) ∗ For N, sizes are in inches.

u Mounting
— Direct mounting
D DIN rail mounting (with DIN rail)
D0 DIN rail mounting (without DIN rail)
ide
Us D3 For 3 stations Specify a length longer
ns
tatio
···

···

S than that of the standard


3 D24 For 24 stations rail.
2
1
ide ∗ Refer to page 319 (SY3000/5000/7000 series:
Ds
Specific product precautions 6) for instructions
Manifold base (5 stations) on fastening the DIN rail mounting type
SS5Y3-12TC-05D manifold.
SS5Y3-12TC-05D ····· 1 set (Type 12 5-station manifold base part no.)
∗ SY3130-5U1-C6 ········3 sets (2-position single part no.)
∗ SY3230-5U1-C6 ········1 set (2-position double part no.)
∗ SY3330-5U1-C6 ········1 set (3-position closed centre part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
• For the valve arrangement, the valve closest to the D side is considered the 1st station.
• Under the manifold part number, state the valves to be mounted in order
starting with the 1st station as shown in the figure above. If the arrangement
becomes too complicated, specify the details on a manifold specification sheet.

66
SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported

q Series y Pilot valve option !1 A, B port size


3 SY3000 — Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K∗1 High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗1 Only the metal seal type is available for the 01 1/8 SY5000

w Type of actuation
high pressure type. 02 1/4 SY7000

1 Single One-touch fitting (Metric)


2
2-position
Double u Coil type Symbol A, B port SY3000 SY5000 SY7000
3 Closed centre — Standard C2 Ø2  — —
4 3-position Exhaust centre T With power saving circuit (Continuous duty type) C3 Ø 3.2  — —
5 Pressure centre ∗ Be sure to select the power saving circuit C4 Ø4   —
A∗1 N.C./N.C. type if the valve is to be continuously C6 Ø6   
4-position  
B∗1 dual 3-port
N.O./N.O. energised for long periods of time. C8 Ø8 —
∗ Be careful of the energising time when the 
C∗1 N.C./N.O. C10 Ø 10 — —
power saving circuit is selected. Refer to C12 Ø 12 — — 
∗1 Only the rubber seal type is available for the page 316 for details.
4-position dual 3-port valve. One-touch fitting (Inch)
Symbol A, B port SY3000 SY5000 SY7000
i Rated voltage N1 Ø 1/8"  — —
e Seal type 5 24 VDC N3 Ø 5/32"   —
6 12 VDC N7 Ø 1/4"   
0 Rubber seal
N9 Ø 5/16" —  
1 Metal seal
N11 Ø 3/8" — — 

o Light/surge voltage suppressor


r Pilot type and common specification
!2 Thread type
Surge voltage Common
— Internal pilot Symbol With light
suppressor specification — Rc
R External pilot
— — — F G
R — Non-polar N NPT
U  T NPTF
t Back pressure check valve S —

Positive ∗ Only — is available for M5.
(Built-in valve type) Z  common
— None NS — Negative
NZ  common
H Built-in
∗ Only the rubber seal type is available. A ∗ For the non-polar type, be careful of surge !3 Type of mounting screw
manifold installed type is available if a back voltage intrusion. — Round head combination screw
pressure check valve with a metal seal is Refer to page 317 for details. B Hexagon socket head cap screw
required. Refer to page 236 for ordering ∗ Only “Z” and “NZ” types are available with a K Round head combination screw (Drop prevention type)
examples. However, it is not recommended power saving circuit. H Hexagon socket head cap screw (Drop prevention type)
to use the built-in valve type and the manifold ∗ For “K” and “H,” the valve body cover has a
installed type at the same time because it will
reduce the flow. !0 Manual override drop prevention construction to stop the
mounting screws from falling out when the
∗ The built-in valve type back pressure check —: D: valve is removed for maintenance, etc.
valve is not available for the 3-position type Non-locking Push-turn ∗ When ordering a valve individually, the
or the SY7000. push type locking base gasket is not included.
slotted type Since the base gasket is attached to the
manifold, please order the base gasket
separately if it is needed for maintenance.
Refer to page 222 for base gasket and
mounting screw part numbers.
∗ “B” and “H” cannot be selected for the
E: F: individual SUP/EXH spacer assembly or
Push-turn Slide locking interface regulator.
locking lever type
type

∗ Refer to page 36 for the safety slide locking


manual override.

Protective class
class # (Mark: )
67
Plug-in Connector Connecting Base SY3000/5000/7000 Series

Terminal Block Connection


Step 1. Remove the terminal block cover Step 2. The diagram below shows the terminal block wiring.
Loosen the 4 mounting screws (M3) to remove the All stations are provided with double wiring regard-
terminal block cover. less of the mounted valves.
Terminal block cover Connect each wire to the power supply side, according to
Mounting screw (M3) the markings provided inside the terminal block.
Be sure to connect the wire with the push button pressed down.

Gasket

6
Drip-proof plug (SY30M-133-1) Push 4A
5A
h 3A
is mounted Pitc m button
1A
2A
m
Tightening torque: 0.8 N·m 3.5 2B
3
1B

Spring type
Conduit port terminal block
2 x M20 x 1.5
Step 3. Mount the terminal block cover
Securely tighten the mounting screws (M3) to the torque
shown in the table below only after confirming that the
gasket is installed correctly.

Proper tightening torque [N·m]


0.54 to 0.66 • Applicable wire range: Conductor diameter Ø 0.5 to Ø 1.2 mm, Stranded wire AWG24 to 16

Electrical Wiring Specifications (IP67 compatible)


Standard wiring Specified Layout
Terminal no. Polarity A mixture of single and double wiring can be
SOL.a (+)
1A (−) specified on the manifold specification sheet.
Station 1 SOL.b
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 13A 14A 15A 16A COM
1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 11B 12B 13B 14B 15B 16B COM

1B (−) (+) The maximum number of stations is deter-


SOL.a (+)
2A (−) mined according to the number of solenoids.
Station 2 SOL.b (+)
2B (−) The total number of solenoids should be 32 or
SOL.a (+)
3A (−) less. 1 solenoid is required for the 2-position
Station 3 SOL.b (+)
3B (−) single, and 2 solenoids for the 2-position dou-
SOL.a (+)
4A (−) ble, 3-position, and 4-position.
Station 4 SOL.b (+)
4B (−)
SOL.a (+)
5A (−)
Station 5 SOL.b (+)
5B (−)
SOL.a (+)
6A (−)
Station 6
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 13A 14A 15A 16A COM
1B 2B 3B 4B 5B 6B 7B 8B 9B 10B 11B 12B 13B 14B 15B 16B COM

SOL.b (+)
6B (−)
SOL.a (+)
7A (−)
Station 7 SOL.b (+)
7B (−)
SOL.a (+)
8A (−)
If alignment is not specified, the Station 8 SOL.b (+)
8B (−)
internal wiring will be double wiring SOL.a (+)
9A (−)
(connected to SOL. a and SOL. b) Station 9 SOL.b
9B (−) (+)
regardless of number of stations, SOL.a
valve types, and option types. 10A (−) (+)
Station 10 SOL.b (+)
10B (−)
SOL.a (+)
11A (−)
Station 11 SOL.b (+)
∗ When using a valve with no 11B (−)
SOL.a (+)
polarity, either positive 12A (−)
common or negative common Station 12 SOL.b (+)
12B (−)
can be used. SOL.a (+)
13A (−)
Station 13 SOL.b (+)
13B (−)
SOL.a (+)
14A (−)
Station 14 SOL.b (+)
14B (−)
SOL.a (+)
15A (−)
Station 15 SOL.b (+)
15B (−)
SOL.a (+)
16A (−)
Station 16 SOL.b (+)
16B (−)

COM. (+) (−)


COM. (+) (−)
Positive Negative
common common

68
Plug-in Connector Connecting Base
Type 10
Side Ported Terminal Block Box

SY3000/5000/7000 Series
Type 11
Bottom Ported

RoHS
How to Order Manifolds

Refer to pages 180 (SY5000) and


SS5Y 3 10 T 05 U C6
181 (SY7000) for the dimensions
of Type 11/Bottom-ported type. q w e r t y u
q Series e Valve stations r P, E port entry
3 SY3000 Symbol Stations Note U U side (2 to 10 stations)
5 SY5000 02 2 stations D D side (2 to 10 stations)
Double wiring∗1

7 SY7000 B Both sides (2 to 20 stations)


10 10 stations
02 2 stations
Specified layout∗2
w Type

(Up to 20 solenoids available)


10 Side ported 20 20 stations t SUP/EXH block assembly
11 Bottom ported∗1 ∗1 Double wiring: 2-position single, double, 3-position, and — Internal pilot
4-position valves can be used on all manifold stations.
∗1 The SY5000 manifold base is S Internal pilot, Built-in silencer
Use of a 2-position single solenoid will result in an
used for the bottom-ported R External pilot
unused control signal. If this is not desired, order with a
SY3000. When ordering, ∗ 3/5(E) port is plugged for the built-in silencer
specified layout.
refer to the “Plug-in Manifold
∗2 Specified layout: Indicate the wiring specifications with type.
Mixed Mounting Type” (from ∗ When the built-in silencer type is used, keep
the manifold specification sheet. (Note that 2-position
page 185). the exhaust port from coming into direct
double, 3-position, and 4-position valves cannot be
used where single wiring has been specified.) contact with water or other liquids.
∗ This also includes the number of the blanking plate
assembly.
Refer to the page on the right for y.
How to Order Manifold Assembly

Example (SS5Y3-10T-)
u Mounting and Option
Option
2-position double (24 VDC) Symbol Mounting
Name plate Station number
2-position single (24 VDC) SY3200-5U1 (1 set) — — —
3-position closed Direct
SY3100-5U1 (3 sets) AA  
centre (24 VDC) mounting
BA  —
SY3300-5U1 (1 set)
D — —
DIN rail
A  
mounting
B  —
∗ Enter the number of stations inside  when it
is larger than the number of valve stations.
ide (Refer to “DIN Rail Option” below.)
Us
s ∗ Only direct mounting is available for the type
ation
St 11 bottom-ported type.
3 ∗ Refer to page 319 for the fixation of DIN rail
2
1 mounting type manifold.
e
D sid
DIN Rail Option
Manifold base
— Standard length
(5 stations)
SS5Y3-10T-05D-C6
0 Without DIN rail (with bracket)
3 For 3 stations
Specify a longer rail than the

SS5Y3-10T-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.) total length of specified stations.
∗SY3100-5U1 ··············· 3 sets (2-position single part no.) 20 For 20 stations
∗SY3200-5U1 ··············· 1 set (2-position double part no.)
∗SY3300-5U1 ··············· 1 set (3-position closed centre part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
• For the valve arrangement, the valve closest to the D side is considered the 1st station.
• Under the manifold part number, state the valves to be mounted in order starting
with the 1st station as shown in the figure above. If the arrangement becomes too
complicated, specify the details on a manifold specification sheet.
∗ When mixing top-ported configurations, select from those listed on page 76.
In such cases, use caution as there is also output on the A and B ports on the base side.
Specify on the manifold specification sheet if plugs are required for the A and B ports on
the base side.
69
Plug-in Connector Connecting Base SY3000/5000/7000 Series

y A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)


Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 Ø2  — — — — N1 Ø 1/8"  — — — —
C3 Ø 3.2  — — — — N3 Ø 5/32"   —  —

Straight
C4 Ø4   —  — N7 Ø 1/4"     
Straight

C6 Ø6      N9 Ø 5/16" —    
C8 Ø8 —     N11 Ø 3/8" — —  — 
C10 Ø 10 — —  —  CM∗1 Straight port, mixed sizes     
C12 Ø 12 — —  —  LN3 Ø 5/32"  — — — —

Upward
CM∗1 Straight port, mixed sizes      LN7 Ø 1/4"   — — —
L4 Ø4   — — — LN9 Ø 5/16" —  — — —
L6 Ø6    — — LN11 Ø 3/8" — —  — —
Upward

Elbow∗2

L8 Ø8 —   — — BN3 Ø 5/32"  — — — —
Downward

L10 Ø 10 — —  — — BN7 Ø 1/4"   — — —


L12 Ø 12 — —  — — BN9 Ø 5/16" —  — — —
Elbow∗2

B4 Ø4   — — — BN11 Ø 3/8" — —  — —
Downward

B6 Ø6    — — Elbow port, mixed sizes


LM∗1 (Including upward and    — —
B8 Ø8 —   — — downward piping)

B10 Ø 10 — —  — — P, E port size Ø


Ø 3/8" Ø 1/2" Ø 3/8" Ø 1/2"
B12 Ø 12 — —  — — (One-touch fittings) 5/16"
Elbow port, mixed sizes
LM∗1 (Including upward and    — —
downward piping)

P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).

Protective class
class # (Mark: )
70
SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

q Series y Pilot valve option !0 Manual override


3 SY3000 — Standard (0.7 MPa) —: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K∗1 High pressure type (1.0 MPa) push type locking
∗1 Only the metal seal type is available for the slotted
high pressure type. type

w Type of actuation
1
2-position
Single u Coil type E: F:
2 Double — Standard Push-turn Slide locking
3 Closed centre T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit lever
5 Pressure centre type if the valve is to be continuously type
A∗1 N.C./N.C. energised for long periods of time.
4-position ∗ Be careful of the energising time when the
B∗1 dual 3-port
N.O./N.O.
C∗1 N.C./N.O. power saving circuit is selected. Refer to page
316 for details. ∗ Refer to page 36 for the safety slide locking
∗1 Only the rubber seal type is available for the manual override.
4-position dual 3-port valve.
i Rated voltage
e Seal type
5
6
24 VDC
12 VDC
!1 Type of mounting screw
— Round head combination screw
0 Rubber seal
B Hexagon socket head cap screw
1 Metal seal
K Round head combination screw (Falling-out-prevention type)
o Light/surge voltage suppressor H Hexagon socket head cap screw (Falling-out-prevention type)
and common specification ∗ For “K” and “H,” the valve body cover has a
r Pilot type Symbol With light
Surge voltage Common drop prevention construction to stop the
mounting screws from falling out when the
— Internal pilot suppressor specification
valve is removed for maintenance, etc.
R External pilot — — —
∗ When ordering a valve individually, the
R — Non-polar base gasket is not included.
U  Since the base gasket is attached to the
S — Positive manifold, please order the base gasket
t Back pressure check valve Z 

common separately if it is needed for maintenance.
(Built-in valve type) NS — Refer to page 222 for base gasket and
Negative
mounting screw part numbers.
— None NZ  common
∗ “B” and “H” cannot be selected for the
H Built-in ∗ For the non-polar type, be careful of surge individual SUP/EXH spacer assembly,
∗ Only the rubber seal type is available. A voltage intrusion. interface regulator, or double check spacer
manifold installed type is available if a back Refer to page 317 for details. assembly with residual pressure release
pressure check valve with a metal seal is ∗ Only “Z” and “NZ” types are available with a valve.
required. Refer to page 236 for ordering power saving circuit.
examples. However, it is not recommended
to use the built-in valve type and the manifold
installed type at the same time because it will
reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.

Protective class
class # (Mark: )
71
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY3000 Series Connector Connecting Base Terminal Block Box

C2
U
SS5Y3-10T- Stations D - C3, N1
C4, N3 (D)
B C6, N7

One-touch fitting One-touch fitting


[1(P), 3/5(E) port] [4(A), 2(B) port]
2 x G3/4 Applicable tube O.D.: Ø 8, Ø 5/16" Applicable tube O.D.: Ø 2
Conduit port : Ø 3.2, Ø 1/8"
(Station 1)---(Station n) : Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"

1 P 1 P
77.7

13.6
10.6

63.1
56.6
45.5

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

21.6
4 A4 A4 A4 A4 A
18

13.2

(For DIN rail


mounting)
7.5
34.9

11.8
(Pitch)
107.1 15.5 P = 10.5 (17.8)

D side U side

(L5) L1
Manual override ∗1
DIN rail holding screw
(For DIN rail mounting)
DIN rail holding screw
(For DIN rail mounting)
(Push-turn locking slotted type:
Press, then rotate it. )
DIN rail 4(A) port side : Blue (For rubber seal)
Light/surge : Grey (For metal seal)
voltage suppressor 2(B) port side : Yellow
D side

U side

8
B A B A B A B A B A
5.5

14 A 14 A 14 A 14 A 14 A
35
126

83

92.6
80

60.5
40.9
4.6

12 B 12 B 12 B 12 B 12 B
20.4
4.6
1.7
16

)
(4.9)

4 x M4 mounting hole
C6: 3.6
N7: 7.4

2 x M5 mounting hole (Fitting for the type with P/E


1
ports on the U and/or D sides)
(

7.1 88.2 L2 1.5

5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3

∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10T-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L1 164.3 174.8 185.3 195.8 206.3 216.8 227.3 237.8 248.3 258.8 269.3 279.8 290.3 300.8 311.3 321.8 332.3 342.8 353.3
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252
L3 198 198 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 335.5 335.5 348 360.5 373 385.5
L4 187.5 187.5 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 325 325 337.5 350 362.5 375
L5 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12 13 14 15 16

72
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY5000 Series Connector Connecting Base Terminal Block Box

U C4, N3
SS5Y5-10T- Stations D - C6, N7 (D)
B C8, N9

One-touch fitting
[1(P), 3/5(E) port] One-touch fitting
Applicable tube O.D.: Ø 10, Ø 3/8" [4(A), 2(B) port]
(Station 1)----------- (Station n) Applicable tube O.D.: Ø 4, Ø 5/32"
2 x G3/4
: Ø 6, Ø 1/4"
Conduit port : Ø 8, Ø 5/16"

14.1
77.7

1 P 1 P

73.2
8.7
2 B2 B2 B2 B2 B

56.6
45.5

33.4

3/5 E 3/5 E

29.1
4 A4 A4 A4 A4 A
13.2

12.4

(For DIN rail


mounting)
34.9

7.5

11.8
(Pitch)
108.8 18 P = 16 (20.5)

D side U side

DIN rail holding screw


(L5) L1 Manual override∗1
(For DIN rail mounting) DIN rail holding screw
(For DIN rail mounting)
(Push-turn locking slotted type:
Press, then rotate it. )
DIN rail 4(A) port side : Blue (For rubber seal)
: Grey (For metal seal)
Light/surge
2(B) port side : Yellow
voltage suppressor
D side

U side

8
BA BA BA BA BA
5.5

35

14 A 14 A 14 A 14 A 14 A
126.4

97.5

113.4
80

81.2
61.7
5.5

12 B 12 B 12 B 12 B 12 B
16.4

1
10.9
4.7
(5.9)
(8.3)

2 x M5 mounting hole
4 x M5 mounting hole
7.1 87.7 L2 1.5
(Fitting for the type with P/E
5.3 L4 ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
L3

∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10T-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L1 181.3 197.3 213.3 229.3 245.3 261.3 277.3 293.3 309.3 325.3 341.3 357.3 373.3 389.3 405.3 421.3 437.3 453.3 469.3
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368
L3 210.5 223 248 260.5 273 285.5 310.5 323 335.5 360.5 373 385.5 398 423 435.5 448 460.5 485.5 498
L4 200 212.5 237.5 250 262.5 275 300 312.5 325 350 362.5 375 387.5 412.5 425 437.5 450 475 487.5
L5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14 12.5 17 15 13.5 11.5 16 14.5

73
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY7000 Series Connector Connecting Base Terminal Block Box

C6, N7
U
SS5Y7-10T- Stations D - C8, N9
C10, N11 (D)
B C12

One-touch fitting One-touch fitting


[1(P), 3/5(E) port] [4(A), 2(B) port]
Applicable tube O.D.: Ø 12, Ø 1/2" Applicable tube O.D.: Ø 6, Ø 1/4"
(Station 1) (Station n) : Ø 8, Ø 5/16"
2 x G3/4 : Ø 10, Ø 3/8"
: Ø 12
Conduit port

2
82.7
1 P 1 P
77.7

2 B2 B2 B2 B2 B

56.6
45.5

11.1
3/5 E 3/5 E

8.7
35.2

31.6
4 A4 A4 A4 A4 A
14.2
13.2

(For DIN rail


(10)
34.9 (21.7)

mounting)
(Pitch)

(14.3)
113.8 20.5 P = 19

D side U side

(L5) L1 Manual override∗1

DIN rail holding screw DIN rail holding screw (Push-turn locking slotted type:
Press, then rotate it. )
(8)

(For DIN rail mounting) (For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor) : Grey (For metal seal)
2(B) port side : Yellow
D side

U side

(8)
(DIN rail)
B A B A B A B A B A
(35)

14 A 14 A 14 A 14 A 14 A
141.8
80

128.8
115
(5.5)

96.7
(77.1)

12 B 12 B 12 B 12 B 12 B
5.5
31.8

1
8.8
3.9
(6)
(9.3)

2 x M5 mounting hole
(17.9)

(A, B port: Ø 12) 4 x M5 mounting hole


7.1 87.9 L2 1.5
(Fitting for the type with P/E
(5.3) (L4) ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10T-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L1 195.5 214.5 233.5 252.5 271.5 290.5 309.5 328.5 347.5 366.5 385.5 404.5 423.5 442.5 461.5 480.5 499.5 518.5 537.5
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436
L3 223 248 260.5 285.5 298 323 335.5 360.5 373 398 410.5 435.5 448 473 485.5 510.5 523 548 573
L4 212.5 237.5 250 275 287.5 312.5 325 350 362.5 387.5 400 425 437.5 462.5 475 500 512.5 537.5 562.5
L5 14 17 13.5 16.5 13.5 16.5 13 16 13 16 12.5 15.5 12.5 15.5 12 15 12 15 18

74
Plug-in Connector Connecting Base
Terminal Block Box

SY3000/5000/7000 Series ®

RoHS
How to Order Manifolds

Refer to pages 182 to 184


for the dimensions of
SS5Y 3 12T 05 U
Type 12/Top-ported type.
q w e r t y
q Series w Valve stations r SUP/EXH block assembly
3 SY3000 Symbol Stations Note — Internal pilot
5 SY5000 02 2 stations S Internal pilot, Built-in silencer
Double wiring∗1

7 SY7000 R External pilot


10 10 stations ∗ The P and E ports are only available on the
02 2 stations U and D sides for the built-in silencer type.
Specified layout∗2
e P, E port entry 3/5(E) port is plugged. The silencer exhaust

(Up to 20 solenoids available) port is located on the opposite side of the P


U∗1 U side (2 to 10 stations) 20 20 stations
and E port entry. (Example: When the P and
D∗1 D side (2 to 10 stations) ∗1 Double wiring: 2-position single, double, E port entry is on the D side, the silencer
B Both sides (2 to 20 stations) 3-position, and 4-position valves can be exhaust port is on the U side.)
used on all manifold stations. ∗ When the built-in silencer type is used, keep
∗1 r For type “S”, SUP/EXH block assembly Use of a 2-position single solenoid will
with a built-in silencer, choose U or D for P, the exhaust port from coming into direct
result in an unused control signal. If this is contact with water or other liquids.
E port entry. not desired, order with a specified layout.
∗2 Specified layout: Indicate the wiring
specifications on the manifold specification
sheet. (Note that 2-position double,
3-position, and 4-position valves cannot be t P, E port size
used where single wiring has been (One-touch fittings)
specified.)
∗ This also includes the number of the blanking
Symbol SY3000 SY5000 SY7000
plate assembly. — Ø8 Ø 10 Ø 12
N Ø 5/16" Ø 3/8" Ø 1/2"
∗ For N, sizes are in inches.
How to Order Manifold Assembly

Example (SS5Y3-12T-)
2-position double (24 VDC) y Mounting
SY3230-5U1-C6 (1 set) — Direct mounting
2-position single (24 VDC) 3-position closed DIN rail mounting
SY3130-5U1-C6 (3 sets) centre (24 VDC) D
(With DIN rail)
SY3330-5U1-C6 (1 set) DIN rail mounting
D0
(Without DIN rail)
D3 For 3 stations Specify a length longer

than that of the standard


D20 For 20 stations rail.
∗ Refer to page 319 for the fixation of DIN rail
ide
Us mounting type manifold.
s
n
tio
ta
S
3
2
1

ide
Ds
Manifold base
(5 stations)
SS5Y3-12T-05D
SS5Y3-12T-05D ············ 1 set (Type 12 5-station manifold base part no.)
∗SY3130-5U1-C6 ············ 3 sets (2-position single part no.)
∗SY3230-5U1-C6 ············ 1 set (2-position double part no.)
∗SY3330-5U1-C6 ············ 1 set (3-position closed centre part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
• For the valve arrangement, the valve closest to the D side is considered the 1st station.
• Under the manifold part number, state the valves to be mounted in
order starting with the 1st station as shown in the figure above. If the
arrangement becomes too complicated, specify the details on a
manifold specification sheet.

75
Plug-in Connector Connecting Base SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported

q Series y Pilot valve option !1 A, B port size


3 SY3000 — Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K∗1 High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗1 Only the metal seal type is available for the 01 1/8 SY5000

w Type of actuation
high pressure type. 02 1/4 SY7000

1 Single One-touch fitting (Metric)


2
2-position
Double u Coil type Symbol A, B port SY3000 SY5000 SY7000
3 Closed centre — Standard C2 Ø2  — —
4 3-position Exhaust centre T With power saving circuit (Continuous duty type) C3 Ø 3.2  — —
5 Pressure centre ∗ Be sure to select the power saving circuit C4 Ø4   —
A∗1 N.C./N.C. type if the valve is to be continuously C6 Ø6   
4-position energised for long periods of time. C8  
B∗1 dual 3-port
N.O./N.O. Ø8 —
∗ Be careful of the energising time when the C10 
C∗1 N.C./N.O. Ø 10 — —
power saving circuit is selected. Refer to page C12 Ø 12 — — 
∗1 Only the rubber seal type is available for the 316 for details.
4-position dual 3-port valve. One-touch fitting (Inch)
Symbol A, B port SY3000 SY5000 SY7000
i Rated voltage N1 Ø 1/8"  — —
e Seal type 5 24 VDC N3 Ø 5/32"   —
6 12 VDC N7 Ø 1/4"   
0 Rubber seal
N9 Ø 5/16" —  
1 Metal seal
N11 Ø 3/8" — — 

o Light/surge voltage suppressor


r Pilot type and common specification
!2 Thread type
Surge voltage Common
— Internal pilot Symbol With light
suppressor specification — Rc
R External pilot
— — — F G
R — Non-polar N NPT
U  T NPTF
t Back pressure check valve S —

Positive ∗ Only — is available for M5.
(Built-in valve type) Z  common
— None NS — Negative
NZ  common
H Built-in
∗ Only the rubber seal type is available. A ∗ For the non-polar type, be careful of surge !3 Type of mounting screw
manifold installed type is available if a back voltage intrusion. — Round head combination screw
pressure check valve with a metal seal is Refer to page 317 for details. B Hexagon socket head cap screw
required. Refer to page 236 for ordering ∗ Only “Z” and “NZ” types are available with a K Round head combination screw (Drop prevention type)
examples. However, it is not recommended power saving circuit. H Hexagon socket head cap screw (Drop prevention type)
to use the built-in valve type and the manifold ∗ For “K” and “H,” the valve body cover has a
installed type at the same time because it will
reduce the flow. !0 Manual override drop prevention construction to stop the
mounting screws from falling out when the
∗ The built-in valve type back pressure check —: D: valve is removed for maintenance, etc.
valve is not available for the 3-position type Non-locking Push-turn ∗ When ordering a valve individually, the
or the SY7000. push type locking base gasket is not included.
slotted type Since the base gasket is attached to the
manifold, please order the base gasket
separately if it is needed for maintenance.
Refer to page 222 for base gasket and
mounting screw part numbers.
∗ “B” and “H” cannot be selected for the
E: F: individual SUP/EXH spacer assembly or
Push-turn Slide locking interface regulator.
locking lever type
type

∗ Refer to page 36 for the safety slide locking


manual override.

Protective class
class # (Mark: )

76
SY3000/5000/7000 Series

Terminal Block Connection


Step 1. Remove the terminal block cover Step 2. The diagram below shows the terminal block wiring.
Loosen the 4 mounting screws (M4) to remove the All stations are provided with double wiring
terminal block cover. regardless of the mounted valves.
Connect each wire to the power supply side, according
Terminal block cover to the markings provided inside the terminal block.
Mounting screw (M4)
M3 screw

Gasket

m
6m
Electrical entry
2 x G3/4

Step 3. Mount the terminal block cover


Securely tighten the screws to the torque shown in the
table below only after confirming that the gasket is
installed correctly.
Proper tightening torque [N·m] • Applicable crimped terminal: 1.25-3S, 1.25Y-3, 1.25Y-3N, 1.25Y-3.5
0.7 to 1.2 • Name plate: VVQ5000-N-T
• Drip-proof plug assembly (for G3/4): AXT100-B06A

Electrical Wiring Specifications (IP67 compatible)


Standard wiring Specified Layout
Terminal no. Polarity A mixture of single and double wiring can be
SOL.a
1A (−) (+) specified on the manifold specification sheet.
Station 1 SOL.b
1B (−) (+) The maximum number of stations is
1A

1B
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM

SOL.a
1B 2B 3B 4B 5B 6B 7B 8B 9B 10B

2A

2A (−) (+) determined according to the number of


2B

Station 2 SOL.b
3A

2B (−) (+) solenoids. The total number of solenoids


3B

SOL.a
4A

3A (−) (+) should be 20 or less. 1 solenoid is required for


4B

Station 3 SOL.b
5A

3B (−) (+) the 2-position single, and 2 solenoids for the


5B

SOL.a
6A 7A

(−)
6B

4A (+) 2-position double, 3-position, and 4-position.


Station 4 SOL.b
7B

4B (−) (+)
8A

SOL.a
8B

5A (−) (+)
9A 10A COM

Station 5 SOL.b
9B 10B

5B (−) (+)
SOL.a
6A (−) (+)
Station 6 SOL.b
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM

6B (−) (+)
SOL.a
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM

1B 2B 3B 4B 5B 6B 7B 8B 9B 10B

7A (−) (+)
Station 7 SOL.b
1B 2B 3B 4B 5B 6B 7B 8B 9B 10B

7B (−) (+)
SOL.a
8A (−) (+)
If alignment is not specified, the Station 8 SOL.b
8B (−) (+)
internal wiring will be double wiring SOL.a
9A (−) (+)
(connected to SOL. a and SOL. b) Station 9 SOL.b
regardless of number of stations, 9B (−) (+)
SOL.a
valve types, and option types. 10A (−) (+)
Station 10 SOL.b
10B (−) (+)

∗ When using a valve with no COM. (+) (−)


polarity, either positive Positive Negative
common or negative common common common
can be used.

77
78
Plug-in Connector Connecting Base
Type 10
Side Ported Lead Wire

SY3000/5000/7000 Series
Type 11
Bottom Ported

RoHS
How to Order Manifolds

Refer to pages 180 (SY5000) and


SS5Y 3 10 L1 1 05 U C6
181 (SY7000) for the dimensions
of Type 11/Bottom-ported type. q w e r t y u i o
q Series e Number of cores t Valve stations
3 SY3000 (Lead wire) (L1) (L3)
5 SY5000 L1 34 cores Symbol Stations Note Symbol Stations Note
7 SY7000 L2 17 cores 02 2 stations 02 2 stations
L3 Double wiring∗1 Double wiring∗1


9 cores
16 16 stations 04 4 stations
w Type 02 2 stations Specified layout∗2 02 2 stations Specified layout∗2
r Lead wire length


(Up to 32 solenoids (Up to 8 solenoids
10 Side ported
24 24 stations available) 08 8 stations available)
11 Bottom ported∗1 1 0.6 m
∗1 The SY5000 manifold base is 2 1.5 m (L2)
used for the bottom-ported 3 3m Symbol Stations Note
SY3000. When ordering, refer 02 2 stations
to the “Plug-in Manifold Mixed Double wiring∗1

Mounting Type” (from page 08 8 stations


185).
02 2 stations Specified layout∗2

(Up to 16 solenoids
16 16 stations available)
∗1 Double wiring: 2-position single, double, 3-position, and 4-position
valves can be used on all manifold stations.
How to Order Manifold Assembly Use of a 2-position single solenoid will result in an unused control
signal. If this is not desired, order with a specified layout.
∗2 Specified layout: Indicate the wiring specifications on the manifold
Example (SS5Y3-10L11-) specification sheet. (Note that 2-position double, 3-position, and
2-position double (24 VDC) 4-position valves cannot be used where single wiring has been
2-position single (24 VDC)
SY3200-5U1 (1 set) specified.)
3-position closed ∗ This also includes the number of the blanking plate assembly.
SY3100-5U1 (3 sets)
centre (24 VDC)
SY3300-5U1 (1 set)
y P, E port entry
U U side (2 to 10 stations)
D D side (2 to 10 stations)
B Both sides (2 to 24 stations)

u SUP/EXH block assembly


e
U sid
ions
Stat — Internal pilot
2
3 S Internal pilot, Built-in silencer
1 R External pilot
e
D sid
∗ 3/5(E) port is plugged for the built-in silencer type.
Manifold base ∗ When the built-in silencer type is used, keep the exhaust port from
(5 stations) coming into direct contact with water or other liquids.
SS5Y3-10L11-05D-C6
SS5Y3-10L11-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.)
∗SY3100-5U1 ··················· 3 sets (2-position single part no.)
∗SY3200-5U1 ··················· 1 set (2-position double part no.)
∗SY3300-5U1 ··················· 1 set (3-position closed centre part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
• For the valve arrangement, the valve closest to the D side is considered the 1st station.
• Under the manifold part number, state the valves to be mounted in order starting
with the 1st station as shown in the figure above. If the arrangement becomes too
complicated, specify the details on a manifold specification sheet.
∗ When mixing top-ported configurations, select from those listed on page 86.
In such cases, use caution as there is also output on the A and B ports on the base side.
Specify on the manifold specification sheet if plugs are required for the A and B ports on
the base side.
79
Plug-in Connector Connecting Base SY3000/5000/7000 Series

i A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)


Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 Ø2  — — — — N1 Ø 1/8"  — — — —
C3 Ø 3.2  — — — — N3 Ø 5/32"   —  —

Straight
C4 Ø4   —  — N7 Ø 1/4"     
Straight

C6 Ø6      N9 Ø 5/16" —    
C8 Ø8 —     N11 Ø 3/8" — —  — 
C10 Ø 10 — —  —  CM∗1 Straight port, mixed sizes     
C12 Ø 12 — —  —  LN3 Ø 5/32"  — — — —

Upward
CM∗1 Straight port, mixed sizes      LN7 Ø 1/4"   — — —
L4 Ø4   — — — LN9 Ø 5/16" —  — — —
L6 Ø6    — — LN11 Ø 3/8" — —  — —
Upward

Elbow∗2

L8 Ø8 —   — — BN3 Ø 5/32"  — — — —
Downward

L10 Ø 10 — —  — — BN7 Ø 1/4"   — — —


L12 Ø 12 — —  — — BN9 Ø 5/16" —  — — —
Elbow∗2

B4 Ø4   — — — BN11 Ø 3/8" — —  — —
Downward

B6 Ø6    — — Elbow port, mixed sizes


LM∗1 (Including upward and    — —
B8 Ø8 —   — — downward piping)

B10 Ø 10 — —  — — P, E port size Ø


Ø 3/8" Ø 1/2" Ø 3/8" Ø 1/2"
B12 Ø 12 — —  — — (One-touch fittings) 5/16"
Elbow port, mixed sizes
LM∗1 (Including upward and    — —
downward piping)

P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).

o Mounting and Option


Option DIN Rail Option
Symbol Mounting
Name plate Station number — Standard length
— — — 0 Without DIN rail (with bracket)
Direct
AA   3 For 3 stations Specify a longer rail than the
mounting


BA — total length of specified


D — — 24 For 24 stations stations.
DIN rail
A  
mounting
B  —
∗ Enter the number of stations inside  when it is larger than the number
of valve stations. (Refer to “DIN Rail Option” above.)
∗ Only direct mounting is available for the type 11 bottom-ported type.
∗ Refer to page 319 for the fixation of DIN rail mounting type manifold.

80
SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

q Series y Pilot valve option !0 Manual override


3 SY3000 — Standard (0.7 MPa) —: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K∗1 High pressure type (1.0 MPa) push type locking
∗1 Only the metal seal type is available for the slotted
high pressure type. type

w Type of actuation
1
2-position
Single u Coil type E: F:
2 Double — Standard
Push-turn Slide locking
3 Closed centre T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit type lever
5 Pressure centre if the valve is to be continuously energised for type
A∗1 N.C./N.C. long periods of time.
B∗1
4-position
N.O./N.O. ∗ Be careful of the energising time when the
dual 3-port power saving circuit is selected. Refer to page
C∗1 N.C./N.O.
316 for details. ∗ Refer to page 36 for the safety slide locking
∗1 Only the rubber seal type is available for the manual override.
4-position dual 3-port valve.
i Rated voltage
5 24 VDC
!1 Type of mounting screw
e Seal type 6 12 VDC
— Round head combination screw
0 Rubber seal B Hexagon socket head cap screw
1 Metal seal K Round head combination screw (Drop prevention type)
o Light/surge voltage suppressor H Hexagon socket head cap screw (Drop prevention type)
and common specification ∗ For “K” and “H,” the valve body cover has a
r Pilot type Symbol With light
Surge voltage Common
suppressor specification
drop prevention construction to stop the
mounting screws from falling out when the
— Internal pilot valve is removed for maintenance, etc.
— — —
R External pilot ∗ When ordering a valve individually, the
R — Non-polar base gasket is not included.
U  Since the base gasket is attached to the
S — Positive manifold, please order the base gasket
t Back pressure check valve Z 

common separately if it is needed for maintenance.
(Built-in valve type) NS — Negative Refer to page 222 for base gasket and
 common mounting screw part numbers.
— None NZ
∗ “B” and “H” cannot be selected for the
H Built-in ∗ For the non-polar type, be careful of surge individual SUP/EXH spacer assembly,
∗ Only the rubber seal type is available. A voltage intrusion. interface regulator, or double check spacer
manifold installed type is available if a back Refer to page 317 for details. assembly with residual pressure release
pressure check valve with a metal seal is ∗ Only “Z” and “NZ” types are available with a valve.
required. Refer to page 236 for ordering power saving circuit.
examples. However, it is not recommended
to use the built-in valve type and the manifold
installed type at the same time because it will
reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.

Protective class
class # (Mark: )
81
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY3000 Series Connector Connecting Base Lead Wire

C2
1 U
SS5Y3-10L 2 - Stations D - C3, N1
C4, N3 (D)
3 B C6, N7
One-touch fitting
[4(A), 2(B) port]
One-touch fitting
Applicable tube O.D.: Ø 2
[1(P), 3/5(E) port] (Station 1)---(Station n) : Ø 3.2, Ø 1/8"
Applicable tube O.D.: Ø 8, Ø 5/16" : Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
1 P 1 P

13.6
10.6

63.1
56.6
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

21.6
4 A4 A4 A4 A4 A
18

(For DIN rail


mounting)
7.5
(Pitch)

11.8
54.8 15.5 P = 10.5 (17.8)

D side U side
Manual override∗1
(L5) L1
DIN rail holding screw
(
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail Light/surge : Grey (For metal seal)
2(B) port side : Yellow
voltage suppressor
5.5

8
B A B A B A B A B A
92.6

14 A 14 A 14 A 14 A 14 A
35

83
67.8

60.5
40.9
4.6

12 B 12 B 12 B 12 B 12 B
17

4.6
1.7
N7: 7.4 )
3.6
(4.9)

(C6:

4 x M4 mounting hole
18 (Fitting for the type with P/E
ports on the U and/or D sides)
43 L2 1.5

(Lead wire length)


5.3 L4 18
0.6 m, 1.5 m, 3 m
(DIN rail mounting hole pitch: 12.5)
L3

∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10L1-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 112 122.5 133 143.5 154 164.5 175 185.5 196 206.5 217 227.5 238 248.5 259 269.5 280 290.5 301 311.5 322 332.5 343
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 135.5 148 160.5 173 185.5 198 210.5 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 335.5 335.5 348 360.5 373
L4 125 137.5 150 162.5 175 187.5 200 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 325 325 337.5 350 362.5
L5 12 13 14 15 16 17 18 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12 13 14 15

82
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY5000 Series Connector Connecting Base Lead Wire

1 U C4, N3
SS5Y5-10L 2 - Stations D - C6, N7 (D)
3 B C8, N9

One-touch fitting
[4(A), 2(B) port]
(Station 1)----------- (Station n) Applicable tube O.D.: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
One-touch fitting : Ø 8, Ø 5/16"
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 10, Ø 3/8"

14.1
1 P 1 P

73.2
2 B2 B2 B2 B2 B

56.6
8.7
33.4

3/5 E 3/5 E

29.1
4 A4 A4 A4 A4 A
12.4

(For DIN rail


mounting)
(Pitch)

7.5

11.8
56.5 18 P = 16 (20.5)

D side U side
Manual override∗1
(L5) L1
DIN rail holding screw (Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail Light/surge : Grey (For metal seal)
voltage suppressor 2(B) port side : Yellow
5.5

8
BA BA BA BA BA
14 A 14 A 14 A 14 A 14 A
35

97.5
113.4
64.4

81.2
61.7
5.5

12 B 12 B 12 B 12 B 12 B
24.2

10.9
4.7
(5.9)
(8.3)

4 x M5 mounting hole
18
(Fitting for the type with P/E
42.5 L2 1.5
18
ports on the U and/or D sides)
(Lead wire length)
0.6 m, 1.5 m, 3 m

5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3

∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10L1-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 129 145 161 177 193 209 225 241 257 273 289 305 321 337 353 369 385 401 417 433 449 465 481
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 160.5 173 185.5 210.5 223 235.5 260.5 273 285.5 298 323 335.5 348 360.5 385.5 398 410.5 435.5 448 460.5 473 498 510.5
L4 150 162.5 175 200 212.5 225 250 262.5 275 287.5 312.5 325 337.5 350 375 387.5 400 425 437.5 450 462.5 487.5 500
L5 16 14 12.5 17 15 13.5 18 16 14.5 12.5 17 15.5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15

83
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY7000 Series Connector Connecting Base Lead Wire

C6, N7
1 U
SS5Y7-10L 2 - Stations D - C8, N9
C10, N11 (D)
3 B C12

(Station 1) (Station n)

One-touch fitting
[1(P), 3/5(E) port]

2
Applicable tube O.D.: Ø 12, Ø 1/2"

82.7
1 P 1 P
2 B2 B2 B2 B2 B

56.6
11.1
3/5 E 3/5 E

8.7
35.2

31.6
4 A4 A4 A4 A4 A
14.2

(For DIN rail


(Pitch)

(10)
(21.7)

mounting)
61.5 20.5 P = 19

(14.3)
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
: Ø 12

D side U side

Manual override ∗1
(L5) L1
DIN rail holding screw (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
(Light/surge voltage suppressor) : Grey (For metal seal)
2(B) port side: Yellow

(8) (DIN rail)

B A B A B A B A B A
(35)

14 A 14 A 14 A 14 A 14 A
64.4

128.8
115
(5.5)

96.7
(77.1)

12 B 12 B 12 B 12 B 12 B
5.5
39.6

(Lead wire length)


0.6 m, 1.5 m, 3 m
8.8
3.9
(6)
(9.3)

(17.9)

18 (A, B port: Ø 12) 4 x M5 mounting hole


42.7 L2 1.5
(Fitting for the type with P/E
(5.3) (L4) ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5) 18
(L3)

∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10L1-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 143.2 162.2 181.2 200.2 219.2 238.2 257.2 276.2 295.2 314.2 333.2 352.2 371.2 390.2 409.2 428.2 447.2 466.2 485.2 504.2 523.2 542.2 561.2
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 173 185.5 210.5 235.5 248 273 285.5 310.5 323 348 360.5 385.5 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5
L4 162.5 175 200 225 237.5 262.5 275 300 312.5 337.5 350 375 387.5 412.5 425 450 462.5 487.5 500 525 537.5 562.5 575
L5 15 11.5 14.5 17.5 14.5 17.5 14 17 14 17 13.5 16.5 13.5 16.5 13 16 13 16 12.5 15.5 12.5 15.5 12

84
Plug-in Connector Connecting Base
Lead Wire

SY3000/5000/7000 Series ®

RoHS
How to Order Manifolds

SS5Y 3 12 L1 1 05 U
Refer to pages 182 to 184
for the dimensions of
Type 12/Top-ported type.
q w e r t y u i
q Series r Valve stations
3 SY3000 (L1) (L3)
5 SY5000 Symbol Stations Note Symbol Stations Note
7 SY7000 02 2 stations 02 2 stations
Double wiring∗1 Double wiring∗1


w Number of cores 16 16 stations 04 4 stations
(Lead wire) e Lead wire length 02 2 stations Specified layout∗2 02 2 stations Specified layout∗2


L1 34 cores 1 0.6 m (Up to 32 solenoids (Up to 8 solenoids
L2 17 cores 2 1.5 m 24 24 stations available) 08 8 stations available)
L3 9 cores 3 3m (L2)
Symbol Stations Note
t P, E port entry 02 2 stations
U∗1 Double wiring∗1

U side (2 to 10 stations)
D∗1 D side (2 to 10 stations) 08 8 stations
B Both sides (2 to 24 stations) 02 2 stations Specified layout∗2

∗1 y For type “S”, SUP/EXH block assembly (Up to 16 solenoids


with a built-in silencer, choose U or D for P, 16 16 stations available)
E port entry. ∗1 Double wiring: 2-position single, double, 3-position, and 4-position
valves can be used on all manifold stations.
Use of a 2-position single solenoid will result in an unused control
How to Order Manifold Assembly signal. If this is not desired, order with a specified layout.
∗2 Specified layout: Indicate the wiring specifications on the manifold
specification sheet. (Note that 2-position double, 3-position, and
Example (SS5Y3-12L11-) 4-position valves cannot be used where single wiring has been
specified.)
2-position double (24 VDC) ∗ This also includes the number of the blanking plate assembly.
SY3230-5U1-C6 (1 set)
2-position single (24 VDC)
3-position closed
y SUP/EXH block assembly
SY3130-5U1-C6 (3 sets) centre (24 VDC) — Internal pilot
SY3330-5U1-C6 (1 set) S Internal pilot, Built-in silencer
R External pilot
∗ The P and E ports are only available on the U and D sides for the built-in
silencer type. 3/5(E) port is plugged. The silencer exhaust port is located
on the opposite side of the P and E port entry. (Example: When the P and
E port entry is on the D side, the silencer exhaust port is on the U side.)
∗ When the built-in silencer type is used, keep the exhaust port from
e coming into direct contact with water or other liquids.
U sid
ns
a tio
St

1
2
3
u P, E port size (One-touch fittings)
e
D sid Symbol SY3000 SY5000 SY7000
Manifold base
(5 stations) — Ø8 Ø 10 Ø 12
SS5Y3-12L11-05D
N Ø 5/16" Ø 3/8" Ø 1/2"
∗ For N, sizes are in inches.
SS5Y3-12L11-05D ··· 1 set (Type 12 5-station manifold base part no.)
∗SY3130-5U1-C6 ······· 3 sets (2-position single part no.)
∗SY3230-5U1-C6 ······· 1 set (2-position double part no.) i Mounting
∗SY3330-5U1-C6 ······· 1 set (3-position closed centre part no.) — Direct mounting
The asterisk denotes the symbol for the assembly. D DIN rail mounting (With DIN rail)
Prefix it to the part numbers of the valve, etc. D0 DIN rail mounting (Without DIN rail)
• For the valve arrangement, the valve closest to the D side is considered the 1st station. D3 For 3 stations Specify a length longer

• Under the manifold part number, state the valves to be mounted in order starting than that of the standard
with the 1st station as shown in the figure above. If the arrangement becomes too D24 For 24 stations rail.
complicated, specify the details on a manifold specification sheet. ∗ Refer to page 319 for the fixation of DIN rail mounting type manifold.

85
Plug-in Connector Connecting Base SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported

q Series y Pilot valve option !1 A, B port size


3 SY3000 — Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K∗1 High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗1 Only the metal seal type is available for the 01 1/8 SY5000
high pressure type. 02 1/4 SY7000

w Type of actuation One-touch fitting (Metric)


1
2-position
Single u Coil type Symbol A, B port SY3000 SY5000 SY7000
2 Double — Standard C2 Ø2  — —
3 Closed centre T With power saving circuit (Continuous duty type) C3 Ø 3.2  — —
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit C4 Ø4   —
5 Pressure centre type if the valve is to be continuously C6 Ø6   
A∗1 N.C./N.C. energised for long periods of time. C8 Ø8 —  
B∗1
4-position
N.O./N.O. ∗ Be careful of the energising time when the C10 Ø 10 — — 
dual 3-port power saving circuit is selected. Refer to page
C∗1 N.C./N.O. C12 Ø 12 — — 
316 for details.
∗1 Only the rubber seal type is available for the One-touch fitting (Inch)
4-position dual 3-port valve.
i Rated voltage Symbol A, B port SY3000 SY5000 SY7000
5 24 VDC N1 Ø 1/8"  — —
6 12 VDC N3 Ø 5/32"   —
e Seal type N7 Ø 1/4"   
0 Rubber seal N9 Ø 5/16" —  
N11 Ø 3/8" — — 
1 Metal seal
o Light/surge voltage suppressor
and common specification
Surge voltage Common
r Pilot type Symbol With light
suppressor specification !2 Thread type
— Internal pilot — — — — Rc
R External pilot R — Non-polar F G
U  N NPT
S — Positive T NPTF

Z  common ∗ Only — is available for M5.
t Back pressure check valve NS — Negative
(Built-in valve type) NZ  common

H
None
Built-in
∗ For the non-polar type, be careful of surge
voltage intrusion.
!3 Type of mounting screw
— Round head combination screw
∗ Only the rubber seal type is available. A Refer to page 317 for details.
manifold installed type is available if a back ∗ Only “Z” and “NZ” types are available with a B Hexagon socket head cap screw
pressure check valve with a metal seal is power saving circuit. K Round head combination screw (Drop prevention type)
required. Refer to page 236 for ordering H Hexagon socket head cap screw (Drop prevention type)
examples. However, it is not recommended ∗ For “K” and “H,” the valve body cover has a
to use the built-in valve type and the manifold !0 Manual override drop prevention construction to stop the
installed type at the same time because it will —: D: mounting screws from falling out when the
reduce the flow. Non-locking Push-turn valve is removed for maintenance, etc.
∗ The built-in valve type back pressure check push type locking slotted ∗ When ordering a valve individually, the
valve is not available for the 3-position type type base gasket is not included.
or the SY7000. Since the base gasket is attached to the
manifold, please order the base gasket
separately if it is needed for maintenance.
Refer to page 222 for base gasket and
mounting screw part numbers.
E: F: ∗ “B” and “H” cannot be selected for the
Push-turn Slide locking individual SUP/EXH spacer assembly or
locking lever type interface regulator.
type

∗ Refer to page 36 for the safety slide locking


manual override.

Protective class
class # (Mark: )
86
SY3000/5000/7000 Series

Electrical Wiring Specifications


Lead wire Electrical characteristics
Item Property
Conductor resistance
34 cores Lead wire 143 or less
Ω/km, 20 °C
AWG26 (0.14 mm2) x 34 cores
Voltage limit
2000
34 1 2 If alignment is not specified, the internal V, 1 minute, AC
33 3
32 26
11
12 4
wiring will be double wiring (connected Insulation resistance
25 17 13 to SOL. a and SOL. b) regardless of 10 or more
31 21 18 5 MΩ/km, 20 °C
30 24 20 19 14 6 number of stations, valve types, and
29 23 15 7 option types. ∗ Cannot be used for movable wiring
22 16
28 8 The minimum bending radius of the
27 10 9
Sheath O.D. cable is 55 mm.
Approx. Ø 8.8

Lead Printed mark


wire (Both sides)
Lead wire no. Polarity colour Type Colour
SOL.a
1 (−) (+) Red
Station 1 SOL.b Orange –
2 (−) (+) Black
SOL.a
3 (−) (+) Light Red
Station 2 SOL.b –
4 (−) (+) grey Black
SOL.a
5 (−) (+) Red
Station 3 SOL.b White –
6 (−) (+) Black
SOL.a
7 (−) (+) Red
Station 4 SOL.b Yellow –
8 (−) (+) Black
SOL.a
9 (−) (+) Red
Station 5 SOL.b Pink –
10 (−) (+) Black
SOL.a
11 (−) (+) Red
Station 6 SOL.b Orange – –
12 (−) (+) Black
SOL.a
13 (−) (+) Light Red
Station 7 SOL.b ––
14 (−) (+) grey Black
SOL.a
15 (−) (+) Red
Station 8 SOL.b White ––
16 (−) (+) Black
SOL.a
17 (−) (+) Red
Station 9 SOL.b Yellow ––
18 (−) (+) Black
SOL.a
19 (−) (+) Red
Station 10 SOL.b Pink ––
20 (−) (+) Black
SOL.a
21 (−) (+) Red
Station 11 SOL.b Orange – – –
22 (−) (+) Black
SOL.a
23 (−) (+) Light Red
Station 12 SOL.b –––
24 (−) (+) grey Black
SOL.a
25 (−) (+) Red
Station 13 SOL.b White –––
26 (−) (+) Black
SOL.a
27 (−) (+) Red
Station 14 SOL.b Yellow –––
28 (−) (+) Black
SOL.a
29 (−) (+) Red
Station 15 SOL.b Pink –––
30 (−) (+) Black
SOL.a 31 (−) (+) Red
Station 16 SOL.b 32 (−) Orange – – – –
(+) Black
COM.
33 (+) (−) Light Red
COM. ––––
34 (+) (−) grey Black
Positive Negative
common common
∗ For negative common specification, a valve for negative
common or a valve without polarity should be used.

Specified Layout
A mixture of single and double wiring can be specified on the
manifold specification. The maximum number of stations is
determined according to the number of solenoids. The total number
of solenoids should be 32 or less. 1 solenoid is required for the
2-position single, and 2 solenoids for the 2-position double,
3-position, and 4-position.

87
Plug-in Connector Connecting Base SY3000/5000/7000 Series

Electrical Wiring Specifications


Lead wire Electrical characteristics
Item Property
Conductor resistance
143 or less
17 cores Lead wire 9 cores Lead wire Ω/km, 20 °C
AWG26 (0.14 mm2) x 17 cores AWG26 (0.14 mm2) x 9 cores Voltage limit
2000
1 V, 1 minute, AC
17 2
1
16 13 8 9 3 9 2 Insulation resistance
10 or more
15 12 10 4
8 5 3 MΩ/km, 20 °C
11 7 4
14 5 6
7 6 ∗ Cannot be used for movable wiring ∗ Cannot be used for movable wiring
The minimum bending radius of the cable The minimum bending radius of the cable
is 45 mm. is 40 mm.
Sheath O.D. Sheath O.D.
Lead Printed mark Lead Printed mark
Ø 6.8 Ø 6.3
wire (Both sides) wire (Both sides)
Lead wire no. Polarity colour Lead wire no. Polarity colour Type Colour
Type Colour
SOL.a SOL.a
1 (−) (+) Red 1 (−) (+) Red
Station 1 SOL.b Orange – Station 1 SOL.b Orange –
2 (−) (+) Black 2 (−) (+) Black
SOL.a SOL.a
3 (−) (+) Light Red 3 (−) (+) Light Red
Station 2 SOL.b – Station 2 SOL.b –
4 (−) (+) grey Black 4 (−) (+) grey Black
SOL.a SOL.a
5 (−) (+) Red 5 (−) (+) Red
Station 3 SOL.b White – Station 3 SOL.b White –
6 (−) (+) Black 6 (−) (+) Black
SOL.a SOL.a
7 (−) (+) Red 7 (−) (+) Red
Station 4 SOL.b Yellow – Station 4 SOL.b Yellow –
8 (−) (+) Black 8 (−) (+) Black
SOL.a COM.
9 (−) (+) Red 9 (+) (−) Pink – Red
Station 5 SOL.b Pink –
10 (−) (+) Black Positive Negative
SOL.a Red common common
11 (−) (+)
Station 6 SOL.b Orange – –
12 (−) (+) Black
SOL.a Red
13 (−) (+) Light
Station 7 SOL.b ––
14 (−) (+) grey Black
SOL.a Red
15 (−) (+)
Station 8 SOL.b White ––
16 (−) (+) Black
COM. Yellow –– Red
17 (+) (−)

Positive Negative
common common

∗ For negative common specification, a valve for negative


common or a valve without polarity should be used.

88
Plug-in Connector Connecting Base
Type 10
Side Ported Circular Connector

SY3000/5000/7000 Series
Type 11
Bottom Ported

RoHS
How to Order Manifolds

Refer to pages 180 (SY5000) and


SS5Y 5 10 M 05 U C6
181 (SY7000) for the dimensions
of Type 11/Bottom-ported type. q w e r t y u
q Series e Valve stations r P, E port entry
3 SY3000 Symbol Stations Note U U side (2 to 10 stations)
5 SY5000 02 2 stations D D side (2 to 10 stations)
Double wiring∗1

7 SY7000 B Both sides (2 to 24 stations)


12 12 stations
02 2 stations
w Type Specified layout∗2 t SUP/EXH block assembly

(Up to 24 solenoids available)


10 Side ported 24 24 stations — Internal pilot
11 Bottom ported∗1 ∗1 Double wiring: 2-position single, double, 3-position, and S Internal pilot, Built-in silencer
∗1 The SY5000 manifold base is 4-position valves can be used on all manifold stations. R External pilot
used for the bottom-ported Use of a 2-position single solenoid will result in an ∗ 3/5(E) port is plugged for the built-in silencer
SY3000. When ordering, refer unused control signal. If this is not desired, order with a type.
to the “Plug-in Manifold Mixed specified layout. ∗ When the built-in silencer type is used, keep
Mounting Type” (from page ∗2 Specified layout: Indicate the wiring specifications on the exhaust port from coming into direct
185). the manifold specification sheet. (Note that 2-position contact with water or other liquids.
double, 3-position, and 4-position valves cannot be
used where single wiring has been specified.)
∗ This also includes the number of the blanking plate
assembly.
Refer to the page on the right for y.

How to Order Manifold Assembly u Mounting and Option


Option
Symbol Mounting
Name plate Station number
Example (SS5Y3-10M-) — — —
Direct
2-position double (24 VDC) AA mounting  
2-position single (24 VDC)
SY3200-5U1 (1 set) BA  —
3-position closed D — —
SY3100-5U1 (3 sets) centre (24 VDC) DIN rail
A mounting  
SY3300-5U1 (1 set)
B  —
∗ Enter the number of stations inside  when it
is larger than the number of valve stations.
(Refer to “DIN Rail Option” below.)
∗ Only direct mounting is available for the type
11 bottom-ported type.
ide ∗ Refer to page 319 for the fixation of DIN rail
s
Us mounting type manifold.
at ion
St
3
2 DIN Rail Option
1
e — Standard length
D sid
Manifold base 0 Without DIN rail (with bracket)
(5 stations) 3 For 3 stations
Specify a longer rail than the

SS5Y3-10M-05D-C6
total length of specified stations.
SS5Y3-10M-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.) 24 For 24 stations
∗SY3100-5U1 ··············· 3 sets (2-position single part no.)
∗SY3200-5U1 ··············· 1 set (2-position double part no.)
∗SY3300-5U1 ··············· 1 set (3-position closed centre part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
• For the valve arrangement, the valve closest to the D side is considered the 1st station.
• Under the manifold part number, state the valves to be mounted in order
starting with the 1st station as shown in the figure above. If the arrangement
becomes too complicated, specify the details on a manifold specification sheet.
∗ When mixing top-ported configurations, select from those listed on page 96.
In such cases, use caution as there is also output on the A and B ports on the base side.
Specify on the manifold specification sheet if plugs are required for the A and B ports on
the base side.

89
Plug-in Connector Connecting Base SY3000/5000/7000 Series

y A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)


Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 Ø2  — — — — N1 Ø 1/8"  — — — —
C3 Ø 3.2  — — — — N3 Ø 5/32"   —  —

Straight
C4 Ø4   —  — N7 Ø 1/4"     
Straight

C6 Ø6      N9 Ø 5/16" —    
C8 Ø8 —     N11 Ø 3/8" — —  — 
C10 Ø 10 — —  —  CM∗1 Straight port, mixed sizes     
C12 Ø 12 — —  —  LN3 Ø 5/32"  — — — —

Upward
CM∗1 Straight port, mixed sizes      LN7 Ø 1/4"   — — —
L4 Ø4   — — — LN9 Ø 5/16" —  — — —
L6 Ø6    — — LN11 Ø 3/8" — —  — —
Upward

Elbow∗2

L8 Ø8 —   — — BN3 Ø 5/32"  — — — —
Downward

L10 Ø 10 — —  — — BN7 Ø 1/4"   — — —


L12 Ø 12 — —  — — BN9 Ø 5/16" —  — — —
Elbow∗2

B4 Ø4   — — — BN11 Ø 3/8" — —  — —
Downward

B6 Ø6    — — Elbow port, mixed sizes


LM∗1 (Including upward and    — —
B8 Ø8 —   — — downward piping)

B10 Ø 10 — —  — — P, E port size Ø


Ø 3/8" Ø 1/2" Ø 3/8" Ø 1/2"
B12 Ø 12 — —  — — (One-touch fittings) 5/16"
Elbow port, mixed sizes
LM∗1 (Including upward and    — —
downward piping)

P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).

Protective class
class # (Mark: )
90
SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

q Series y Pilot valve option !0 Manual override


3 SY3000 — Standard (0.7 MPa) —: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K∗1 High pressure type (1.0 MPa) push type locking
∗1 Only the metal seal type is available for the slotted
high pressure type. type

w Type of actuation
1
2-position
Single u Coil type E: F:
2 Double — Standard Push-turn Slide locking
3 Closed centre T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit lever
5 Pressure centre type if the valve is to be continuously type
A∗1 N.C./N.C. energised for long periods of time.
B∗1
4-position
N.O./N.O. ∗ Be careful of the energising time when the
dual 3-port power saving circuit is selected. Refer to
C∗1 N.C./N.O.
page 316 for details. ∗ Refer to page 36 for the safety slide locking
∗1 Only the rubber seal type is available for the manual override.
4-position dual 3-port valve.
i Rated voltage
5 24 VDC
6 12 VDC
!1 Type of mounting screw
e Seal type — Round head combination screw
0 Rubber seal B Hexagon socket head cap screw
1 Metal seal
o Light/surge voltage suppressor K Round head combination screw (Drop prevention type)
and common specification H Hexagon socket head cap screw (Drop prevention type)
Surge voltage Common ∗ For “K” and “H,” the valve body cover has a
r Pilot type Symbol With light
suppressor specification drop prevention construction to stop the
mounting screws from falling out when the
— Internal pilot — — —
valve is removed for maintenance, etc.
R External pilot R — Non-polar ∗ When ordering a valve individually, the
U  base gasket is not included.
S — Positive Since the base gasket is attached to the

Z  common manifold, please order the base gasket
t Back pressure check valve NS — Negative separately if it is needed for maintenance.
(Built-in valve type)  common Refer to page 222 for base gasket and
NZ
mounting screw part numbers.
— None ∗ For the non-polar type, be careful of surge ∗ “B” and “H” cannot be selected for the
H Built-in voltage intrusion. individual SUP/EXH spacer assembly,
∗ Only the rubber seal type is available. A Refer to page 317 for details. interface regulator, or double check spacer
manifold installed type is available if a back ∗ Only “Z” and “NZ” types are available with a assembly with residual pressure release
pressure check valve with a metal seal is power saving circuit. valve.
required. Refer to page 236 for ordering
examples. However, it is not recommended
to use the built-in valve type and the manifold
installed type at the same time because it will
reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.

Protective class
class # (Mark: )
91
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY3000 Series Connector Connecting Base Circular Connector

C2
U
SS5Y3-10M- Stations D - C3, N1
C4, N3 (D)
B C6, N7
One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] (Station 1)---(Station n) Applicable tube O.D.: Ø 2
Applicable tube O.D.: Ø 8, Ø 5/16" : Ø 3.2, Ø 1/8"
: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
1 P 1 P

63.1
13.6
10.6

56.6
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

21.6
4 A4 A4 A4 A4 A
18

(For DIN rail


Circular connector (26 pins)

mounting)
7.5
(Pitch)

11.8
made by CONINVERS GmbH 54.8 15.5 P = 10.5 (17.8)

D side U side
(L5) L1 Manual override ∗1

DIN rail holding screw (


Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail Light/surge : Grey (For metal seal)
voltage suppressor 2(B) port side : Yellow
5.5

8
B A B A B A B A B A
92.6

14 A 14 A 14 A 14 A 14 A
35

83
67.8

60.5
40.9
4.6

12 B 12 B 12 B 12 B 12 B
21.9

4.6
1.7
)
C6: 3.6
N7: 7.4
(4.9)

4 x M4 mounting hole
18
(Fitting for the type with P/E ports on the U and/or D sides)
(

18
43 L2 1.5
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3

Circular connector cable assembly


GAXT100-MC26-015: 1.5 m
GAXT100-MC26-030: 3 m
GAXT100-MC26-050: 5 m

∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10M-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 112 122.5 133 143.5 154 164.5 175 185.5 196 206.5 217 227.5 238 248.5 259 269.5 280 290.5 301 311.5 322 332.5 343
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 135.5 148 160.5 173 185.5 198 210.5 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 335.5 335.5 348 360.5 373
L4 125 137.5 150 162.5 175 187.5 200 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 325 325 337.5 350 362.5
L5 12 13 14 15 16 17 18 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12 13 14 15

92
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY5000 Series Connector Connecting Base Circular Connector

U C4, N3
SS5Y5-10M- Stations D - C6, N7 (D)
B C8, N9

One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 4, Ø 5/32"
(Station 1)----------- (Station n) : Ø 6, Ø 1/4"
One-touch fitting : Ø 8, Ø 5/16"
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 10, Ø 3/8"

14.1
1 P 1 P

73.2
2 B2 B2 B2 B2 B

56.6
12.4

8.7
3/5 E 3/5 E

29.1
33.4

4 A4 A4 A4 A4 A

(For DIN rail


mounting)
7.5
(Pitch)

11.8
56.5 18 P = 16 (20.5)

Circular connector (26 pins)


made by CONINVERS GmbH

D side U side
Manual override∗1
(L5) L1
DIN rail holding screw
(Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
: Grey (For metal seal)
DIN rail Light/surge voltage suppressor
2(B) port side : Yellow
5.5

8
BA BA BA BA BA
14 A 14 A 14 A 14 A 14 A
35

97.5
113.4
64.4

81.2
61.7
5.5

12 B 12 B 12 B 12 B 12 B
24.2

10.9
4.7

18
(5.9)
(8.3)

18 4 x M5 mounting hole

42.5 L2 1.5 (Fitting for the type with P/E


ports on the U and/or D sides)
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3

Circular connector cable assembly


GAXT100-MC26-015: 1.5 m
GAXT100-MC26-030: 3 m
GAXT100-MC26-050: 5 m

∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10M-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.

93
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY7000 Series Connector Connecting Base Circular Connector

C6, N7
U
SS5Y7-10M- Stations D - C8, N9
C10, N11 (D)
B C12

One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 6, Ø 1/4"
(Station 1) (Station n)
: Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
: Ø 12
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 12, Ø 1/2"

2
82.7
1 P 1 P
2 B2 B2 B2 B2 B

56.6
11.1
3/5 E 3/5 E

8.7
35.2

31.6
4 A4 A4 A4 A4 A
14.2

(For DIN rail


(Pitch)

(10)
(21.7)

mounting)
61.5 20.5 P = 19

(14.3)
Circular connector (26 pins)
Made by CONINVERS GmbH

D side U side

Manual override∗1
(L5) L1
DIN rail holding screw (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
: Grey (For metal seal)
(Light/surge voltage suppressor) 2(B) port side: Yellow

(8) (DIN rail)

B A B A B A B A B A
(35)

14 A 14 A 14 A 14 A 14 A
64.4

128.8
115
(5.5)

96.7
(77.1)
5.5

12 B 12 B 12 B 12 B 12 B
39.6

8.8
3.9
(6)

18
(9.3)

(17.9)

(A, B port: Ø 12) 4 x M5 mounting hole


18
42.7 L2 1.5 (Fitting for the type with P/E ports
(5.3) (L4) on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

Circular connector cable assembly


GAXT100-MC26-015: 1.5 m
GAXT100-MC26-030: 3 m
GAXT100-MC26-050: 5 m

∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10M-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 143.2 162.2 181.2 200.2 219.2 238.2 257.2 276.2 295.2 314.2 333.2 352.2 371.2 390.2 409.2 428.2 447.2 466.2 485.2 504.2 523.2 542.2 561.2
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 173 185.5 210.5 235.5 248 273 285.5 310.5 323 348 360.5 385.5 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5
L4 162.5 175 200 225 237.5 262.5 275 300 312.5 337.5 350 375 387.5 412.5 425 450 462.5 487.5 500 525 537.5 562.5 575
L5 15 11.5 14.5 17.5 14.5 17.5 14 17 14 17 13.5 16.5 13.5 16.5 13 16 13 16 12.5 15.5 12.5 15.5 12

94
Plug-in Connector Connecting Base
Circular Connector
Type 12
Top Ported
SY3000/5000/7000 Series ®

RoHS
How to Order Manifolds

SS5Y 3 12M 05 U
Refer to pages 182 to 184
for the dimensions of
Type 12/Top-ported type.
q w e r t y
q Series w Valve stations e P, E port entry
3 SY3000 Symbol Stations Note U∗1 U side (2 to 10 stations)
5 SY5000 02 2 stations D∗1 D side (2 to 10 stations)
Double wiring∗1

7 SY7000 B Both sides (2 to 24 stations)


12 12 stations ∗1 r For type “S”, SUP/EXH block assembly
02 2 stations with a built-in silencer, choose U or D for P,
Specified layout∗2 E port entry.

(Up to 24 solenoids available)


24 24 stations
∗1 Double wiring: 2-position single, double,
3-position, and 4-position valves can be
used on all manifold stations.
Use of a 2-position single solenoid will
r SUP/EXH block assembly
result in an unused control signal. If this is
— Internal pilot
not desired, order with a specified layout. S Internal pilot, Built-in silencer
∗2 Specified layout: Indicate the wiring R External pilot
specifications on the manifold specification ∗ The P and E ports are only available on the U
sheet. (Note that 2-position double, and D sides for the built-in silencer type.
3-position, and 4-position valves cannot be 3/5(E) port is plugged. The silencer exhaust
used where single wiring has been port is located on the opposite side of the P
specified.) and E port entry. (Example: When the P and
∗ This also includes the number of the blanking E port entry is on the D side, the silencer
plate assembly. exhaust port is on the U side.)
∗ When the built-in silencer type is used, keep
the exhaust port from coming into direct
How to Order Manifold Assembly contact with water or other liquids.

Example (SS5Y3-12M-)
2-position single (24 VDC)
2-position double (24 VDC)
SY3230-5U1-C6 (1 set)
t P, E port size (One-touch fittings)
SY3130-5U1-C6 (3 sets) Symbol SY3000 SY5000 SY7000
3-position closed
centre (24 VDC)
— Ø8 Ø 10 Ø 12
SY3330-5U1-C6 (1 set)
N Ø 5/16" Ø 3/8" Ø 1/2"
∗ For N, sizes are in inches.

Us
ide
y Mounting
ns
atio — Direct mounting
St
3 DIN rail mounting
2 D (With DIN rail)
1
ide
Ds
DIN rail mounting
D0 (Without DIN rail)
Manifold base (5 stations)
D3 For 3 stations Specify a length longer
SS5Y3-12M-05D

than that of the standard


D24 For 24 stations rail.
SS5Y3-12M-05D ········ 1 set (Type 12 5-station manifold base part no.)
∗SY3130-5U1-C6 ········ 3 sets (2-position single part no.)
∗ Refer to page 319 for the fixation of DIN rail
mounting type manifold.
∗SY3230-5U1-C6 ········ 1 set (2-position double part no.)
∗SY3330-5U1-C6 ········ 1 set (3-position closed centre part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
• For the valve arrangement, the valve closest to the D side is considered the 1st station.
• Under the manifold part number, state the valves to be mounted in order
starting with the 1st station as shown in the figure above. If the arrangement
becomes too complicated, specify the details on a manifold specification sheet.

95
Plug-in Connector Connecting Base SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported

q Series y Pilot valve option !1 A, B port size


3 SY3000 — Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K∗1 High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗1 Only the metal seal type is available for the 01 1/8 SY5000
high pressure type. 02 1/4 SY7000

w Type of actuation One-touch fitting (Metric)


1
2-position
Single u Coil type Symbol A, B port SY3000 SY5000 SY7000
2 Double — Standard C2 Ø2  — —
3 Closed centre T With power saving circuit (Continuous duty type) C3 Ø 3.2  — —
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit C4 Ø4   —
5 Pressure centre type if the valve is to be continuously C6 Ø6   
A∗1 N.C./N.C. energised for long periods of time. C8 Ø8 —  
4-position ∗ Be careful of the energising time when the C10 
B∗1 dual 3-port
N.O./N.O. Ø 10 — —
power saving circuit is selected. Refer to C12 
C∗1 N.C./N.O. Ø 12 — —
page 316 for details.
∗1 Only the rubber seal is available for the One-touch fitting (Inch)
4-position dual 3-port valve. i Rated voltage Symbol A, B port SY3000 SY5000 SY7000
5 24 VDC N1 Ø 1/8"  — —
6 12 VDC N3 Ø 5/32"   —
e Seal type N7 Ø 1/4"   
N9 Ø 5/16" —  
0 Rubber seal
N11 Ø 3/8" — — 
1 Metal seal o Light/surge voltage suppressor
and common specification
Surge voltage Common
r Pilot type
Symbol With light
suppressor specification !2 Thread type
— — — — Rc
— Internal pilot
R — Non-polar F G
R External pilot
U  N NPT
S — Positive T NPTF

Z  common ∗ Only — is available for M5.
t Back pressure check valve NS — Negative
(Built-in valve type) NZ  common

H
None
Built-in
∗ For the non-polar type, be careful of surge
voltage intrusion.
!3 Type of mounting screw
Refer to page 317 for details. — Round head combination screw
∗ Only the rubber seal type is available. A
∗ Only “Z” and “NZ” types are available with a B Hexagon socket head cap screw
manifold installed type is available if a back
power saving circuit. K Round head combination screw (Falling-out-prevention type)
pressure check valve with a metal seal is
required. Refer to page 236 for ordering H Hexagon socket head cap screw (Falling-out-prevention type)
examples. However, it is not recommended
to use the built-in valve type and the manifold !0 Manual override ∗ For “K” and “H,” the valve body cover has a
drop prevention construction to stop the
installed type at the same time because it will —: D: mounting screws from falling out when the
reduce the flow. Non-locking Push-turn valve is removed for maintenance, etc.
∗ The built-in valve type back pressure check push type locking ∗ When ordering a valve individually, the
valve is not available for the 3-position type slotted base gasket is not included.
or the SY7000. type Since the base gasket is attached to the
manifold, please order the base gasket
separately if it is needed for maintenance.
Refer to page 222 for base gasket and
mounting screw part numbers.
E: F: ∗ “B” and “H” cannot be selected for the
Push-turn Slide locking individual SUP/EXH spacer assembly or
locking type interface regulator.
lever
type

∗ Refer to page 36 for the safety slide locking


manual override.

Protective class
class # (Mark: )
96
SY3000/5000/7000 Series

Electrical Wiring Specifications Cable Assembly


015
Circular connector
AXT100-MC26- 030
If alignment is not specified, the 050
internal wiring will be double wiring Cable
!5 q (connected to SOL. a and SOL. b) 0.3 mm2 x 26 cores
!4 !6 w
regardless of number of stations, O.D. Ø 1.4 Lead wire colour for circular
!3 @4 !7 e
valve types, and option types. connector cable assembly
!2 @3 @5 !8 r
Approx. Ø 10 by terminal number
!1 @2 @6 !9 t Lead
!0 @1 @0 y
Terminal Dot
Seal (Length) wire
no. colour marking
o i u
015 1
2
3
Black
Brown
Red
None
None
None
4 Orange None
Terminal no. Polarity
5 Yellow None
SOL.a
1 (−) (+) 6 Pink None
Station 1 SOL.b
2 (−) (+) 7 Blue None
SOL.a
3 (−) (+) 8 Purple White

L
Station 2 SOL.b
4 (−) (+) 9 Grey Black
SOL.a
5 (−) (+) 10 White Black
Station 3 SOL.b
6 (−) (+)

60
11 White Red
SOL.a
7 (−) (+) 12 Yellow Red
Station 4 SOL.b
8 (−) (+) 13 Orange Red
SOL.a Plug
9 (−) (+) 14 Yellow Black
Station 5 SOL.b
10 (−) (+) 15 Pink Black
SOL.a
11 (−) (+) 16 Blue White
Station 6 SOL.b
12 (−) (+) 17 Purple None
SOL.a
13 (−) (+) 18 Grey None
Station 7 SOL.b
14 (−) (+) 19 Orange Black
SOL.a Ø 30
15 (−) (+) 20 Red White
Station 8 SOL.b
16 (−) (+) 21 Brown White
SOL.a 1 15
17 (−) (+) 2 14 Terminal no. 22 Pink Red
Station 9 SOL.b 17
16
24
18 (−) (+) 3 13 23 Grey Red
SOL.a 25
19 (−) (+) 18 23
4 12 24 Black White
Station 10 SOL.b
20 (−) (+) 19 26 22 25 White None
SOL.a 5
20 21
11
21 (−) (+) 26 White None
Station 11 SOL.b 6 10
22 (−) (+) 7 9
M27 female
SOL.a 8 thread
23 (−) (+) Electrical characteristics
Station 12 SOL.b
24 (−) (+) Item Property
COM.
25 (+) (−) Conductor
COM. 65 or
26 (+) (−) resistance
less
Ω/km, 20 °C
Positive Negative
Voltage limit
common common 1000
V, 1 minute, AC
Circular connector cable assembly
Insulation
Cable Assembly part no. 5 or
resistance
length (L) 26 pins more
MΩ/km, 20 °C
∗ When using a valve with no polarity, either positive common or 1.5 m AXT100-MC26-015
negative common can be used. ∗ The minimum bending
3m AXT100-MC26-030 radius of the circular
5m AXT100-MC26-050 connector cable is 20
∗ Cannot be used for movable wiring mm.
∗ Lengths other than the above is also
Specified Layout available. Please contact SMC for details.
A mixture of single and double wiring can be specified on the manifold
specification sheet. The maximum number of stations is determined
according to the number of solenoids. The total number of solenoids
should be 24 or less. 1 solenoid is required for the 2-position single,
and 2 solenoids for the 2-position double, 3-position, and 4-position.

97
98
Plug-in Connector Connecting Base
Type 10
Side Ported EX500 Gateway Decentralised System 2 (128 Points)
Type 11
Bottom Ported
SY3000/5000/7000 Series ®

RoHS
How to Order Manifolds

Refer to pages 180 (SY5000) and SS5Y 3 10 S A3N 05 U C6


181 (SY7000) for the dimensions
of Type 11/Bottom-ported type.
q w e r t y u i
q Series e SI unit (Number of outputs, Output polarity, r Valve stations
3 SY3000 Max. number of valve stations) Stations Note
5 SY5000 0 Without SI unit 02 2 stations
Double wiring∗1


7 SY7000 32 outputs∗1∗4, 2 to 16 stations (24
A3N stations∗3), Negative common∗2 16 16 stations
∗ For mixed mounting, refer to page 185 and
later. ∗1 16 outputs can be set by switching the built-in 02 2 stations
Specified layout∗2


setting switch. (Up to 32 solenoids available)
∗2 Ensure a match with the common specification 24 24 stations
w Type of the valve. ∗1 Double wiring: 2-position single, double,
10 Side ported ∗3 ( ): Maximum number of stations for mixed 3-position, and 4-position valves can be
11 Bottom ported∗1 single and double wiring used on all manifold stations.
∗1 The SY5000 manifold base is used for the ∗4 When using the SI unit with 32 outputs, use Use of a 2-position single solenoid will
bottom-ported SY3000. When ordering, the GW unit compatible with the EX500 result in an unused control signal.
refer to the “Plug-in Manifold Mixed Gateway Decentralised System 2 (128 points). If this is not desired, order with a specified
Mounting Type” (from page 185). layout.
∗ When mixing top-ported configurations, ∗2 Specified layout: Indicate the wiring
select from those listed on +page 114. specifications on the manifold specification
In such cases, use caution as there is also sheet. (Note that 2-position double,
output on the A and B ports on the base side. 3-position, and 4-position valves cannot be
Specify on the manifold specification sheet if used where single wiring has been
plugs are required for the A and B ports on specified.)
the base side. ∗ When the product without the SI unit (S0) is
selected, note the maximum number of
solenoids of the SI unit that will be mounted.
If the layout is specified, indicate it on the
How to Order Manifold Assembly manifold specification sheet.
∗ This also includes the number of the blanking
plate assembly.
Example
Manifold base 2-position double
t P, E port entry
U U side (2 to 10 stations)
D D side (2 to 10 stations)
B Both sides (2 to 24 stations)

y SUP/EXH block assembly


— Internal pilot
S Internal pilot, Built-in silencer∗1∗2
R External pilot
de
si

∗1 3/5(E) port is plugged for the built-in


U
ns
tio

silencer type.
ta
S

∗2 When built-in silencer type is used, keep


3
2

the exhaust port from coming into direct


1
de

contact with water or other liquids.


si
D

SS5Y3-10SA3N-05D-C6···1 set (Manifold base part number)


∗ SY3200-5U1···················5 sets (2-position double part number)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
∗ A separate GW unit and communication cable are required.
• For the valve arrangement, the valve closest to the D side is considered
the 1st station. For details on the EX500 Gateway Type Serial Transmission
• Under the manifold base part number, state the valves to be mounted System, refer to the Web Catalogue and the Operation
in order starting with the 1st station as shown in the figure above. If the Manual. For the part numbers of the SI units to be mounted,
arrangement becomes too complicated, specify the details on a refer to page 208. Please download the Operation Manual via
manifold specification sheet. the SMC website, https://www.smc.eu

99
Plug-in Connector Connecting Base SY3000/5000/7000 Series

u A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)


Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
A, B port A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 Ø2  — — — — N1 Ø 1/8"  — — — —
C3 Ø 3.2  — — — — N3 Ø 5/32"   —  —

Straight
C4 Ø4   —  — N7 Ø 1/4"     
Straight

C6 Ø6      N9 Ø 5/16" —    
C8 Ø8 —     N11 Ø 3/8" — —  — 
C10 Ø 10 — —  —  CM∗1 Mixed sizes     
C12 Ø 12 — —  —  LN3 Ø 5/32"  — — — —

Upward
CM∗1 Mixed sizes      LN7 Ø 1/4"   — — —
L4 Ø4   — — — LN9 Ø 5/16" —  — — —
L6 Ø6    — — LN11 Ø 3/8" — —  — —
Upward

Elbow∗2

L8 Ø8 —   — — BN3 Ø 5/32"  — — — —
Downward

L10 Ø 10 — —  — — BN7 Ø 1/4"   — — —


L12 Ø 12 — —  — — BN9 Ø 5/16" —  — — —
Elbow∗2

B4 Ø4   — — — BN11 Ø 3/8" — —  — —
Downward

B6 Ø6    — —
LM∗1 Mixed sizes    — —
B8 Ø8 —   — —
B10 Ø 10 — —  — —
P, E port∗3 Ø 5/16" Ø 3/8" Ø 1/2" Ø 3/8" Ø 1/2"
B12 Ø 12 — —  — —

LM∗1 Mixed sizes    — —

P, E port∗3 Ø8 Ø 10 Ø 12 Ø 10 Ø 12

∗1 Indicate the sizes on the manifold specification sheet.


∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).
∗3 The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.

i Mounting and Option


Option
Mounting
Name plate Station number
— — —
Direct
AA  
mounting
BA  —
D∗1 — —
DIN rail
A∗1  
mounting
B∗1  —
∗1 Refer to “DIN Rail Option” below.
∗ Select the direct mounting type for Type 11 (Bottom ported).
DIN Rail Option
— With DIN bracket, DIN rail with standard length
0 With DIN bracket, without DIN rail
3∗1 With DIN bracket, DIN rail for 3 stations

24∗1 With DIN bracket, DIN rail for 24 stations


∗1 Specify a longer rail than the length of valve stations.
∗ If the DIN rail must be mounted without an SI unit, select “D0” and order the
DIN rail separately. Refer to L3 of the dimensions for the DIN rail length.
Refer to page 227 for the DIN rail part number.
∗ Refer to page 319 for the fixation of DIN rail mounting type manifold.

Protective class
class # (Mark: )
100
SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

q Series y Pilot valve option !0 Manual override


3 SY3000 — Standard (0.7 MPa) — D
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K∗1 High pressure type (1.0 MPa) push type locking
∗1 Select the metal seal type for the high slotted
pressure type. type

w Type of actuation
1 Single
2
2-position
Double u Coil type E
Push-turn
F
Slide locking
3 Closed centre — Standard locking type
4 3-position Exhaust centre
T
With power saving circuit lever
5 Pressure centre (Continuous duty type)∗1∗2 type
A∗1 N.C./N.C. ∗1 Be sure to select the power saving circuit
4-position dual
B∗1 3-port valve
N.O./N.O. type if the valve is to be continuously
C∗1 N.C./N.O. energised for long periods of time.
∗2 Be careful of the energising time when the ∗ Refer to page 36 for the safety slide locking
∗1 Select the rubber seal type for the 4-position manual override.
dual 3-port valve. power saving circuit is selected. For details,
refer to page 316.

!1 Type of mounting screw


e Seal type
0 Rubber seal i Rated voltage —
B
Round head combination screw
Hexagon socket head cap screw
1 Metal seal 5 24 VDC
Round head combination screw
K (Drop prevention type)∗1
Hexagon socket head cap screw
r Pilot type o Light/surge voltage suppressor H (Drop prevention type)∗1
and common specification ∗1 For “K” and “H,” the valve body cover has a
— Internal pilot
Surge voltage Common drop prevention construction to stop the
R External pilot With light mounting screws from falling out when the
suppressor specification
valve is removed for maintenance, etc.
R — ∗ When ordering a valve individually, the
Non-polar
U  base gasket is not included.
t Back pressure check valve NS —

Negative Since the base gasket is attached to the
— None NZ  common manifold, please order the base gasket
H∗1 Built-in separately if it is needed for maintenance.
∗ For the non-polar type, be careful of surge Refer to page 222 for base gasket and
∗1 Select the rubber seal type when the back voltage intrusion. mounting screw part numbers.
pressure check valve is built-in. A manifold Refer to page 317 for details. ∗ Select “—” or “K” for the optional individual
installed type is available if a back pressure ∗ Select “NZ” for models with a power saving SUP/EXH spacer assembly, interface
check valve with a metal seal is required. circuit. regulator, or double check spacer assembly
Refer to page 236 for ordering examples. with residual pressure release valve.
However, it is not recommended to use the
built-in valve type and the manifold installed
type at the same time because it will reduce
the flow.
∗ Select “—” for the 3-position type or the
SY7000.

Protective class
class # (Mark: )
101
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY3000 Series Connector Connecting Base EX500 (128 Points)

U C2
SS5Y3-10SA3N- Stations DB -C3, N1
C4, N3 (D)
C6, N7

One-touch fitting
[1(P), 3/5(E) port] One-touch fitting
Applicable tube O.D.: Ø 8, Ø 5/16"
[4(A), 2(B) port]
(Station 1) (Station n)
M12 Applicable tube O.D.: Ø 2
: Ø 3.2, Ø 1/8"
: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
OUT
1 P 1 P
76.7
67.2

10.6
13.6

63.1
IN

56.6
46.2

3/5 E 3/5 E

(11.8)
2 B2 B2 B2 B2 B
40.2
25.6

21.6
4 A4 A4 A4 A4 A
18

M12 11.3 (Pitch)

(7.5)
46.5 15.5 P = 10.5 (17.8)

D side U side

Light/surge voltage suppressor Manual override∗1


(L5) L1 4(A) port side: Blue (for rubber seal)
: Grey (for metal seal)
2(B) port side: Yellow
(5.5)

(8)
B A B A B A B A B A
(35)

92.6

14 A 14 A 14 A 14 A 14 A
83
80.2

60.5
(40.9)

12 B 12 B 12 B 12 B 12 B
21.2

4.6

4.6
1.7
)
C6: 3.6
N7: 7.4
(4.9)

4 x M4 Mounting hole
SI Unit
(

L2 1.5 (Fitting for the type with P/E ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10SA3N-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.

L: Dimensions n: Stations
L n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 103.7 114.2 124.7 135.2 145.7 156.2 166.7 177.2 187.7 198.2 208.7 219.2 229.7 240.2 250.7
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210
L3 135.5 148 148 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5
L4 125 137.5 137.5 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275
L5 16 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5

L n 17 18 19 20 21 22 23 24
L1 261.2 271.7 282.2 292.7 303.2 313.7 324.2 334.7
L2 220.5 231 241.5 252 262.5 273 283.5 294
L3 285.5 298 310.5 323 335.5 348 348 360.5
L4 275 287.5 300 312.5 325 337.5 337.5 350
L5 12 13 14 15 16 17 12 13
102
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY5000 Series Connector Connecting Base EX500 (128 Points)

U C4, N3
SS5Y5-10SA3N- Stations DB -C6, N7 (D)
C8, N9

One-touch fitting
[1(P), 3/5(E) port] One-touch fitting
Applicable tube O.D.: Ø 10, Ø 3/8" (Station 1) (Station n) [4(A), 2(B) port]
Applicable tube O.D.: Ø 4, Ø 5/32"
M12
: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"

OUT

14.1
76.7

1 P 1 P

73.2
67.2

IN 2 B2 B2 B2 B2 B

56.6
46.2

(11.8)
3/5 3/5
33.4

E E

29.1
25.6

4 A4 A4 A4 A4 A
8.7
12.4

11.3 (Pitch)

(7.5)
M12 48.2 18 P = 16 (20.5)

D side U side
Light/surge voltage suppressor Manual override∗1
(L5) L1 4(A) port side: Blue (for rubber seal)
: Grey (for metal seal)
2(B) port side: Yellow
(5.5)

(8)
B A B A B A B A B A
(35)

14 A 14 A 14 A 14 A 14 A
97.5
113.4
101

81.2
(61.7)
5.5

12 B 12 B 12 B 12 B 12 B
10.9
0.4

4.7
(5.9)
(8.3)

SI Unit
34.2 L2 1.5
(5.3) (L4) 4 x M5 Mounting hole
(DIN rail mounting hole pitch: 12.5) (Fitting for the type with P/E ports on the U and/or D sides)
(L3)

∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10SA3N-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.

L: Dimensions n: Stations
L n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304
L3 148 160.5 185.5 198 210.5 235.5 248 260.5 273 298 310.5 323 348 360.5 373
L4 137.5 150 175 187.5 200 225 237.5 250 262.5 287.5 300 312.5 337.5 350 362.5
L5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14

L n 17 18 19 20 21 22 23 24
L1 360.7 376.7 392.7 408.7 424.7 440.7 456.7 472.7
L2 320 336 352 368 384 400 416 432
L3 385.5 410.5 423 435.5 448 473 485.5 498
L4 375 400 412.5 425 437.5 462.5 475 487.5
L5 12.5 17 15 13.5 11.5 16 14.5 12.5
103
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY7000 Series Connector Connecting Base EX500 (128 Points)

U C6, N7
SS5Y7-10SA3N- Stations DB -C8, N9
C10, N11 (D)
C12

One-touch fitting One-touch fitting


[1(P), 3/5(E) port] [4(A), 2(B) port]
Applicable tube O.D.: Ø 12, Ø 1/2" (Station 1) (Station n) Applicable tube O.D.: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
M12 : Ø 10, Ø 3/8"
: Ø 12

2
OUT

11.1

82.7
1 P 1 P
76.7

S
2 B2 B2 B2 B2 B
67.2

IN

56.6
46.2

(14.3)
3/5 E 3/5 E
35.2

31.6
4 A4 A4 A4 A4 A
25.6

8.7
14.2

11.3 (Pitch)

(10)
M12 53.2 20.5 P = 19 21.7

D side U side

Light/surge voltage suppressor Manual override∗1


(L5) L1 4(A) port side: Blue (for rubber seal)
: Grey (for metal seal)
2(B) port side: Yellow

(8)

B A B A B A B A B A
(35)

14 A 14 A 14 A 14 A 14 A
101.4

128.8
115
96.7
(5.5)

(77.1)
5.5

12 B 12 B 12 B 12 B 12 B
15

8.8
3.9
(6)
(N13: 20.4)

SI Unit
(9.3)

(17.9)

(A, B port: Ø 12) 4 x M5 Mounting hole


34.4 L2 1.5
(5.3) (L4) (Fitting for the type with P/E ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10SA3N-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.

L: Dimensions n: Stations
L n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 134.9 153.9 172.9 191.9 210.9 229.9 248.9 267.9 286.9 305.9 324.9 343.9 362.9 381.9 400.9
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360
L3 160.5 185.5 198 223 235.5 260.5 273 298 310.5 335.5 348 373 398 410.5 435.5
L4 150 175 187.5 212.5 225 250 262.5 287.5 300 325 337.5 362.5 387.5 400 425
L5 13 16 12.5 15.5 12.5 15.5 12 15 12 15 11.5 14.5 17.5 14.5 17.5

L n 17 18 19 20 21 22 23 24
L1 419.9 438.9 457.9 476.9 495.9 514.9 533.9 552.9
L2 379 398 417 436 455 474 493 512
L3 448 473 485.5 510.5 523 548 560.5 585.5
L4 437.5 462.5 475 500 512.5 537.5 550 575
L5 14 17 14 17 13.5 16.5 13.5 16.5
104
Plug-in Connector Connecting Base
Type 10
Side Ported EX500 Gateway Decentralised System (64 Points)

SY3000/5000/7000 Series
Type 11
Bottom Ported

RoHS
How to Order Manifolds

Refer to pages 180 (SY5000) and


SS5Y 3 10 S A2 05 U C6
181 (SY7000) for the dimensions
of Type 11/Bottom-ported type. q w e r t y u i
q Series e SI unit (Number of outputs, Output polarity, r Valve stations
3 SY3000 Max. number of valve stations) Stations Note
5 SY5000 0 Without SI unit 02 2 stations
Double wiring∗1


7 SY7000 16 outputs,
∗ For mixed mounting, refer to page 185 and A2 Positive common∗1, 08 8 stations
later. 2 to 8 stations (16 stations)∗2 02 2 stations
Specified layout∗2


16 outputs, (Up to 16 solenoids available)
Negative common∗1, 16 16 stations
w Type A2N
2 to 8 stations (16 stations)∗2 ∗1 Double wiring: 2-position single, double,
10 Side ported ∗1 Ensure a match with the common 3-position, and 4-position valves can be
11 Bottom ported∗1 specification of the valve to be used. used on all manifold stations.
∗1 The SY5000 manifold base is used for the ∗2 ( ): Maximum number of stations for mixed Use of a 2-position single solenoid will
bottom-ported SY3000. When ordering, single and double wiring result in an unused control signal. If this is
refer to the “Plug-in Manifold Mixed not desired, order with a specified layout.
Mounting Type” (from page 185). ∗2 Specified layout: Indicate the wiring
∗ When mixing top-ported configurations, specifications on the manifold specification
select from those listed on page 114. sheet. (Note that 2-position double,
In such cases, use caution as there is also 3-position, and 4-position valves cannot be
output on the A and B ports on the base side. used where single wiring has been
Specify on the manifold specification sheet if specified.)
plugs are required for the A and B ports on ∗ When the product without the SI unit (S0) is
the base side. selected, note the maximum number of
solenoids of the SI unit that will be mounted.
If the layout is specified, indicate it on the
manifold specification sheet.
How to Order Manifold Assembly ∗ This also includes the number of the blanking
plate assembly.

Example (SS5Y3-10SA2-)
2-position double (24 VDC) t P, E port entry
2-position single (24 VDC) SY3200-5U1 (1 set) U U side (2 to 10 stations)
SY3100-5U1 (3 sets) D D side (2 to 10 stations)
3-position closed
centre (24 VDC) B Both sides (2 to 16 stations)
SY3300-5U1 (1 set)

y SUP/EXH block assembly


— Internal pilot
S Internal pilot, Built-in silencer
R External pilot
ide ∗ 3/5(E) port is plugged for the built-in silencer
Us
type.
s
n
tio

∗ When the built-in silencer type is used, keep


ta
S

3 the exhaust port from coming into direct


2 contact with water or other liquids.
1
ide
Ds
Manifold base (5 stations)
SS5Y3-10SA2-05D-C6

SS5Y3-10SA2-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.)


∗SY3100-5U1···················· 3 sets (2-position single part no.)
∗SY3200-5U1···················· 1 set (2-position double part no.)
∗SY3300-5U1···················· 1 set (3-position closed centre part no.)
The asterisk denotes the symbol for the assembly. ∗ A separate GW unit and communication cable are required.
Prefix it to the part numbers of the valve, etc. For details on the EX 5 0 0 Gateway Type Serial Transmission
• For the valve arrangement, the valve closest to the D side is considered the 1st station. System, refer to the Web Catalogue and the Operation
• Under the manifold part number, state the valves to be mounted in order Manual. For the part numbers of the SI units to be mounted,
starting with the 1st station as shown in the figure above. If the arrangement refer to page 209. Please download the Operation Manual via
becomes too complicated, specify the details on a manifold specification sheet. the SMC website, https://www.smc.eu

105
Plug-in Connector Connecting Base SY3000/5000/7000 Series

u A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)


Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
A, B port A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 Ø2  — — — — N1 Ø 1/8"  — — — —
C3 Ø 3.2  — — — — N3 Ø 5/32"   —  —

Straight
C4 Ø4   —  — N7 Ø 1/4"     
Straight

C6 Ø6      N9 Ø 5/16" —    
C8 Ø8 —     N11 Ø 3/8" — —  — 
C10 Ø 10 — —  —  CM∗1 Mixed sizes     
C12 Ø 12 — —  —  LN3 Ø 5/32"  — — — —

Upward
CM∗1 Mixed sizes      LN7 Ø 1/4"   — — —
L4 Ø4   — — — LN9 Ø 5/16" —  — — —
L6 Ø6    — — LN11 Ø 3/8" — —  — —
Upward

Elbow∗2

L8 Ø8 —   — — BN3 Ø 5/32"  — — — —
Downward

L10 Ø 10 — —  — — BN7 Ø 1/4"   — — —


L12 Ø 12 — —  — — BN9 Ø 5/16" —  — — —
Elbow∗2

B4 Ø4   — — — BN11 Ø 3/8" — —  — —
Downward

B6 Ø6    — —
LM∗1 Mixed sizes    — —
B8 Ø8 —   — —
B10 Ø 10 — —  — — P, E port∗3
Ø 5/16" Ø 3/8" Ø 1/2" Ø 3/8" Ø 1/2"
B12 Ø 12 — —  — — (One-touch fittings)

LM∗1 Mixed sizes    — —

P, E port∗3
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).
∗3 The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.

i Mounting and Option


Option
Mounting
Name plate Station number
— — —
Direct
AA  
mounting
BA  —
D∗1 — —
DIN rail
A∗1  
mounting
B∗1  —
∗1 Refer to “DIN Rail Option” below.
∗ Select the direct mounting type for Type 11 (Bottom ported).
DIN Rail Option
— With DIN bracket, DIN rail with standard length
0 With DIN bracket, without DIN rail
3∗1 With DIN bracket, DIN rail for 3 stations

16∗1 With DIN bracket, DIN rail for 16 stations


∗1 Specify a longer rail than the length of valve stations.
∗ If the DIN rail must be mounted without an SI unit, select “D0” and order the
DIN rail separately. Refer to L3 of the dimensions for the DIN rail length.
Refer to page 227 for the DIN rail part number.
∗ Refer to page 319 for the fixation of DIN rail mounting type manifold.

Protective class
class # (Mark: )
106
SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

q Series y Pilot valve option !0 Manual override


3 SY3000 — Standard (0.7 MPa) —: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K∗1 High pressure type (1.0 MPa) push type locking
∗1 Only the metal seal type is available for the slotted
high pressure type. type

w Type of actuation
1
2-position
Single u Coil type E: F:
2 Double — Standard Push-turn Slide locking
3 Closed centre T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit lever
5 Pressure centre type if the valve is to be continuously type
A∗1 N.C./N.C. energised for long periods of time.
B∗1
4-position
N.O./N.O. ∗ Be careful of the energising time when the
dual 3-port power saving circuit is selected. Refer to page
C∗1 N.C./N.O.
316 for details. ∗ Refer to page 36 for the safety slide locking
∗1 Only the rubber seal type is available for the manual override.
4-position dual 3-port valve.
i Rated voltage
5
!1 Type of mounting screw
24 VDC
e Seal type — Round head combination screw
0 Rubber seal
B Hexagon socket head cap screw
1 Metal seal o Light/surge voltage suppressor K Round head combination screw (Drop prevention type)
and common specification H Hexagon socket head cap screw (Drop prevention type)
Symbol With light
Surge voltage Common ∗ For “K” and “H,” the valve body cover has a
r Pilot type suppressor specification drop prevention construction to stop the
mounting screws from falling out when the
— Internal pilot R —
Non-polar valve is removed for maintenance, etc.
R External pilot U 
∗ When ordering a valve individually, the
S — Positive
 base gasket is not included.
Z  common Since the base gasket is attached to the
NS — Negative manifold, please order the base gasket
t Back pressure check valve NZ  common separately if it is needed for maintenance.
(Built-in valve type) ∗ For the non-polar type, be careful of surge Refer to page 222 for base gasket and
voltage intrusion. mounting screw part numbers.
— None
Refer to page 317 for details. ∗ “B” and “H” cannot be selected for the
H Built-in individual SUP/EXH spacer assembly,
∗ Only “Z” and “NZ” are available with a power
∗ Only the rubber seal type is available. A saving circuit. Select “R,” “U,” “S,” or “Z” for interface regulator, or double check spacer
manifold installed type is available if a back the valve when the SI unit specification is A2 assembly with residual pressure release
pressure check valve with a metal seal is (positive common). Select “R,” “U,” “NS,” or valve.
required. Refer to page 236 for ordering “NZ” for the valve when the SI unit
examples. However, it is not recommended specification is A2N (negative common).
to use the built-in valve type and the manifold
installed type at the same time because it will
reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.

Protective class
class # (Mark: )
107
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY3000 Series Connector Connecting Base EX500 (64 Points)

C2
U
SS5Y3-10SA2- Stations D - C3, N1
C4, N3 (D)
B C6, N7

One-touch fitting
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 8, Ø 5/16" [4(A), 2(B) port]
(Station 1)---(Station n) Applicable tube O.D.: Ø 2
M12 : Ø 3.2, Ø 1/8"
8-pin socket : Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
0
1 P 1 P

63.1
10.6
13.6

56.6
1
60
43.2

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2
22.2

21.6
4 A4 A4 A4 A4 A
18

(For DIN rail


M12

(7.5)

mounting)
17.5 (Pitch)

(11.8)
8-pin plug
46.3 15.5 P = 10.5 (17.8)

D side U side
Manual override∗1

DIN rail holding screw


(For DIN rail mounting)
(L5) L1
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
: Grey (For metal seal)
(Light/surge voltage suppressor) 2(B) port side : Yellow
SI unit
(5.5)

(8)
B A B A B A B A B A
(35)

92.6

14 A 14 A 14 A 14 A 14 A
83
67.8

60.5
(40.9)

12 B 12 B 12 B 12 B 12 B
4.6

4.6
1.7
N7: 7.4 )
(4.9)
3.6
12.1

4 x M4 mounting hole
(C6:

(Fitting for the type with P/E ports on the U and/or D sides)
34.5 L2 1.5
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

∗1 Refer to page 177 or dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10SA2-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 103.5 114 124.5 135 145.5 156 166.5 177 187.5 198 208.5 219 229.5 240 250.5
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210
L3 135.5 148 148 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5
L4 125 137.5 137.5 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275
L5 16 17 12 13 14 15 16 17 18 12.5 13.5 14.5 15.5 16.5 17.5

108
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY5000 Series Connector Connecting Base EX500 (64 Points)

U C4, N3
SS5Y5-10SA2- Stations D - C6, N7 (D)
B C8, N9

One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: Ø 4, Ø 5/32"
Applicable tube O.D.: Ø 10, Ø 3/8" (Station 1)----------- (Station n) : Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
M12
8-pin socket
0

14.1
1 P 1 P

73.2
2 B2 B2 B2 B2 B

56.6
60

1
43.2
33.4

3/5 E 3/5 E

29.1
22.2

4 A4 A4 A4 A4 A
12.4
8.7

(For DIN rail


mounting)
(7.5)
17.5

(11.8)
M12 (Pitch)
48 18 P = 16 (20.5)
8-pin plug

D side U side
Manual override∗1
(L5) L1
DIN rail holding screw (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor) : Grey (For metal seal)
SI unit 2(B) port side : Yellow

DIN rail
(5.5)

(8)
BA BA BA BA BA
(35)

14 A 14 A 14 A 14 A 14 A
97.5
113.4
79.9

81.2
(61.7)
5.5

12 B 12 B 12 B 12 B 12 B
10.9
8.7

4.7
(5.9)
(8.3)

4 x M5 mounting hole

34 L2 1.5
(Fitting for the type with P/E
(5.3) (L4) ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10SA2-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 120.5 136.5 152.5 168.5 184.5 200.5 216.5 232.5 248.5 264.5 280.5 296.5 312.5 328.5 344.5
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304
L3 148 160.5 185.5 198 210.5 235.5 248 260.5 273 298 310.5 323 348 360.5 373
L4 137.5 150 175 187.5 200 225 237.5 250 262.5 287.5 300 312.5 337.5 350 362.5
L5 14 12 16.5 15 13 17.5 16 14 12.5 17 15 13.5 18 16 14.5

109
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY7000 Series Connector Connecting Base EX500 (64 Points)

C6, N7
U
SS5Y7-10SA2- Stations D - C8, N9
C10, N11 (D)
B C12

One-touch fitting
[4(A), 2(B) port]
One-touch fitting
Applicable tube O.D.: Ø 6, Ø 1/4"
[1(P), 3/5(E) port] (Station 1) (Station n) : Ø 8, Ø 5/16"
Applicable tube O.D.: Ø 12, Ø 1/2" : Ø 10, Ø 3/8"
M12 : Ø 12
8-pin socket

2
0

82.7
1 P 1 P
2 B2 B2 B2 B2 B

56.6
1
60
43.2

11.1
3/5 E 3/5 E
35.2

8.7

31.6
4 A4 A4 A4 A4 A
22.2
14.2

(For DIN rail


(10)
17.5 (21.7)

(14.3)
(Pitch)

mounting)
M12
8-pin plug 53 20.5 P = 19

D side U side
(L5) L1 Manual override∗1

DIN rail holding screw (


Push-turn locking slotted type:
Press, then rotate it. )
SI unit (For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
: Grey (For metal seal)
(Light/surge voltage suppressor)
2(B) port side: Yellow

(8) (DIN rail)

B A B A B A B A B A
(35)

14 A 14 A 14 A 14 A 14 A
128.8
115
79.9

(5.5)

96.7
(77.1)

12 B 12 B 12 B 12 B 12 B
5.5
24.1

8.8
3.9
(6)
(9.3)

(17.9)

(A, B port: Ø 12) 4 x M5 mounting hole

34.2 L2 1.5 (Fitting for the type with P/E


(5.3) (L4) ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10SA2-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 134.7 153.7 172.7 191.7 210.7 229.7 248.7 267.7 286.7 305.7 324.7 343.7 362.7 381.7 400.7
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360
L3 160.5 185.5 198 223 235.5 260.5 273 298 310.5 335.5 348 373 398 410.5 435.5
L4 150 175 187.5 212.5 225 250 262.5 287.5 300 325 337.5 362.5 387.5 400 425
L5 13 16 12.5 15.5 12.5 15.5 12 15 12 15 11.5 14.5 17.5 14.5 17.5

110
Plug-in Connector Connecting Base
EX500 Gateway Decentralised System 2 (128 Points)

SY3000/5000/7000 Series ®

RoHS
How to Order Manifolds

SS5Y 3 12S A3N 05 U


Refer to pages 182 to 184
for the dimensions of q w e r t y u
Type 12/Top-ported type.

q Series e Valve stations r P, E port entry


3 SY3000 Stations Note U∗1 U side (2 to 10 stations)
5 SY5000 02 2 stations D∗1 D side (2 to 10 stations)
Double wiring∗1

7 SY7000 B Both sides (2 to 24 stations)


∗ For mixed mounting, refer to page 185 and 16 16 stations ∗1 For type “S”, SUP/EXH block assembly
later. 02 2 stations with a built-in silencer, choose U or D for P,
Specified layout∗2

E port entry.
(Up to 32 solenoids available)
24 24 stations
w SI unit (Number of outputs, Output polarity,
Max. number of valve stations)
∗1 Double wiring: 2-position single, double,
3-position, and 4-position valves can be used on
t SUP/EXH block assembly
0 Without SI unit all manifold stations. Use of a 2-position single — Internal pilot
32 outputs∗1∗4, 2 to 16 stations (24 solenoid will result in an unused control signal. If S∗1 Internal pilot, Built-in silencer∗2
A3N stations∗3), Negative common∗2 this is not desired, order with a specified layout. R External pilot
∗1 16 outputs can be set by switching the ∗2 Specified layout: Indicate the wiring ∗1 For type “S”, SUP/EXH block assembly
built-in setting switch. specifications on the manifold specification with a built-in silencer, choose U or D for P,
∗2 Ensure a match with the common sheet. (Note that 2-position double, E port entry. 3/5(E) port is plugged. The
specification of the valve. 3-position, and 4-position valves cannot be silencer exhaust port is located on the
∗3 ( ): Maximum number of stations for used where single wiring has been specified.) opposite side of the P and E port entry.
mixed single and double wiring ∗ When the product without the SI unit (S0) is (Example: When the P and E port entry is
∗4 When using the SI unit with 32 outputs, selected, note the maximum number of on the D side, the silencer exhaust port is
use the GW unit compatible with the solenoids of the SI unit that will be mounted. on the U side.)
EX500 Gateway Decentralised System 2 If the layout is specified, indicate it on the ∗2 When the built-in silencer type is used,
(128 points). manifold specification sheet. keep the exhaust port from coming into
∗ This also includes the number of the blanking direct contact with water or other liquids.
plate assembly.

How to Order Manifold Assembly y P, E port size (One-touch fittings)


SY3000 SY5000 SY7000
Example 2-position double — Ø8 Ø 10 Ø 12
N∗1 Ø 5/16" Ø 3/8" Ø 1/2"
∗1 For N, sizes are in inches.

u Mounting
— Direct mounting
D With DIN bracket, DIN rail with standard length
D0 With DIN bracket, without DIN rail
D3∗1 With DIN bracket, DIN rail for 3 stations
de


si
U

D24∗1 With DIN bracket, DIN rail for 24 stations


ns
tio
ta
S

∗1 Specify a longer rail than the length of valve stations.


3

∗ If the DIN rail must be mounted without an SI unit, select “D0.”


2
1
de

Then, refer to L3 of the dimensions for the DIN rail length and
si
D

order separately. Refer to page 227 for the DIN rail part number.
Manifold base ∗ Refer to page 319 for the fixation of DIN rail mounting type
manifold.
SS5Y3-12SA3N-05D ········1 set (Manifold base part number)
∗ SY3230-5U1-C6 ·············5 sets (2-position double part number)
∗ A separate GW unit and communication cable are required.
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc. For details on the EX500 Gateway Type Serial Transmission
System, refer to the Web Catalogue and the Operation
• For the valve arrangement, the valve closest to the D side is considered the 1st station. Manual. For the part numbers of the SI units to be mounted,
• Under the manifold base part number, state the valves to be mounted in order refer to page 208. Please download the Operation Manual via
starting with the 1 st station as shown in the figure above. If the arrangement the SMC website, https://www.smc.eu
becomes too complicated, specify the details on a manifold specification sheet.

111
Plug-in Connector Connecting Base SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported

q Series y Pilot valve option !1 A, B port size


3 SY3000 — Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Port size SY3000 SY5000 SY7000
7 SY7000 K∗1 High pressure type (1.0 MPa) M5 M5 x 0.8  — —
∗1 Select the metal seal type for the high 01 1/8 —  —
pressure type. 02 1/4 — — 
w Type of actuation One-touch fitting (Metric)
1
2-position
Single u Coil type A, B port SY3000 SY5000 SY7000
2 Double C2 Ø2  — —
— Standard
3 Closed centre C3 Ø 3.2  — —
With power saving circuit
4 3-position Exhaust centre T (Continuous duty type)∗1∗2 C4 Ø4   —
5 Pressure centre C6 Ø6   
∗1 Be sure to select the power saving circuit
A∗1 N.C./N.C. C8 Ø8 —  
4-position dual type if the valve is to be continuously
B∗1 N.O./N.O. energised for long periods of time. C10 Ø 10 — — 
3-port valve
C∗1 N.C./N.O. ∗2 Be careful of the energising time when the C12 Ø 12 — — 
∗1 Select the rubber seal type for the 4-position power saving circuit is selected. One-touch fitting (Inch)
dual 3-port valve. Refer to page 316 for details. A, B port SY3000 SY5000 SY7000
N1 Ø 1/8"  — —
i Rated voltage N3 Ø 5/32"   —
e Seal type 5 24 VDC
N7 Ø 1/4"   
N9 Ø 5/16" —  
0 Rubber seal
N11 Ø 3/8" — — 
1 Metal seal
o Light/surge voltage suppressor
and common specification
r Pilot type With light
Surge voltage Common !2 A, B port thread type
suppressor specification
— Internal pilot — Rc
R — F G
R External pilot Non-polar
U  N NPT

NS — Negative T NPTF
NZ  common
∗ Select “—” for M5.
t Back pressure check valve ∗ For the non-polar type, be careful of surge
(Built-in valve type) voltage intrusion.
Refer to page 317 for details.
— None
∗ Select “NZ” for models with a power saving !3 Type of mounting screw
H∗1 Built-in circuit. — Round head combination screw
∗1 Select the rubber seal type when the back B Hexagon socket head cap screw
pressure check valve is built-in. A manifold
installed type is available if a back pressure !0 Manual override K
Round head combination screw
(Drop prevention type∗1)
check valve with a metal seal is required. — D
Refer to page 236 for ordering examples. Hexagon socket head cap screw
Non-locking Push-turn H (Drop prevention type∗1)
However, it is not recommended to use the
push type locking
built-in valve type and the manifold installed ∗1 For “K” and “H,” the valve body cover has a
slotted
type at the same time because it will reduce drop prevention construction to stop the
type
the flow. mounting screws from falling out when the
∗ Select “—” for the 3-position type or the valve is removed for maintenance, etc.
SY7000. ∗ When ordering a valve individually, the
base gasket is not included.
E F Since the base gasket is attached to the
Push-turn Slide locking manifold, please order the base gasket
locking lever type separately if it is needed for maintenance.
type Refer to page 222 for base gasket and
mounting screw part numbers.
∗ Select “—” or “K” for the optional individual
SUP/EXH spacer assembly or interface
regulator.
∗ Refer to page 36 for the safety slide locking
manual override.

Protective class
class # (Mark: )
112
Plug-in Connector Connecting Base
EX500 Gateway Decentralised System (64 Points)
Type 12
Top Ported
SY3000/5000/7000 Series ®

RoHS
How to Order Manifolds

SS5Y 3 12S A2 05 U
Refer to pages 182 to 184
for the dimensions of
Type 12/Top-ported type.
q w e r t y u
q Series r P, E port entry e Valve stations
3 SY3000 U∗1 U side (2 to 10 stations) Symbol Stations Note
5 SY5000 D∗1 D side (2 to 10 stations) 02 2 stations
Double wiring∗1


7 SY7000 B Both sides (2 to 16 stations)
∗ For mixed mounting, refer to page 185 and ∗1 tFor type “S”, SUP/EXH block assembly 08 8 stations
later. with a built-in silencer, choose U or D for P, 02 2 stations
E port entry. Specified layout∗2


(Up to 16 solenoids available)
16 16 stations
w SI unit (Number of outputs, Output polarity, ∗1 Double wiring: 2-position single, double,
Max. number of valve stations) t SUP/EXH block assembly 3-position, and 4-position valves can be
0 Without SI unit — Internal pilot used on all manifold stations.
16 outputs, S Internal pilot, Built-in silencer Use of a 2-position single solenoid will
A2 Positive common∗1, R External pilot result in an unused control signal. If this is
not desired, order with a specified layout.
2 to 8 stations (16 stations)∗2 ∗ The P and E ports are only available on the ∗2 Specified layout: Indicate the wiring
16 outputs, U and D sides for the built-in silencer type. specifications on the manifold specification
A2N Negative common∗1, 3/5(E) port is plugged. The silencer exhaust sheet. (Note that 2-position double,
2 to 8 stations (16 stations)∗2 port is located on the opposite side of the P 3-position, and 4-position valves cannot be
and E port entry. (Example: When the P and used where single wiring has been
∗1 Ensure a match with the common E port entry is on the D side, the silencer
specification of the valve to be used. specified.)
exhaust port is on the U side.) ∗ When the product without the SI unit (S0) is
∗2 ( ): Maximum number of stations for mixed ∗ When the built-in silencer type is used, keep
single and double wiring selected, note the maximum number of
the exhaust port from coming into direct solenoids of the SI unit that will be mounted.
contact with water or other liquids. If the layout is specified, indicate it on the
manifold specification sheet.
How to Order Manifold Assembly ∗ This also includes the number of the blanking
plate assembly.

Example (SS5Y3-12SA2-)
2-position double (24 VDC)
y P, E port size (One-touch fittings)
SY3230-5U1-C6 (1 set) Symbol SY3000 SY5000 SY7000
2-position single (24 VDC)
SY3130-5U1-C6 (3 sets) 3-position closed — Ø8 Ø 10 Ø 12
centre (24 VDC) N Ø 5/16" Ø 3/8" Ø 1/2"
SY3330-5U1-C6 (1 set)
∗ For N, sizes are in inches.

u Mounting
— Direct mounting
ide D With DIN bracket, DIN rail with standard length
Us D0 With DIN bracket, without DIN rail
s
n

D3∗1
tio

With DIN bracket, DIN rail for 3 stations


ta
S

3
2 D16∗1 With DIN bracket, DIN rail for 16 stations
1
ide
Manifold base Ds ∗1 Specify a longer rail than the length of valve stations.
(5 stations) ∗ If the DIN rail must be mounted without an SI unit, select
SS5Y3-12SA2-05D “D0.” Then, refer to L3 of the dimensions for the DIN rail
length and order separately. Refer to page 227 for the DIN
rail part number.
SS5Y3-12SA2-05D ··· 1 set (Type 12 5-station manifold base part no.)
∗ Refer to page 319 for the fixation of DIN rail mounting type
∗SY3130-5U1-C6 ········ 3 sets (2-position single part no.)
manifold.
∗SY3230-5U1-C6 ········ 1 set (2-position double part no.)
∗SY3330-5U1-C6 ········ 1 set (3-position closed centre part no.)
The asterisk denotes the symbol for the assembly.
∗ A separate GW unit and communication cable are required.
Prefix it to the part numbers of the valve, etc. For details on the EX500 Gateway Type Serial Transmission
• For the valve arrangement, the valve closest to the D side is considered the 1st station. System, refer to the Web Catalogue and the Operation
• Under the manifold part number, state the valves to be mounted in order Manual. For the part numbers of the SI units to be mounted,
starting with the 1st station as shown in the figure above. If the arrangement refer to page 2 0 9 . Please download the Operation Manual
becomes too complicated, specify the details on a manifold specification sheet. via the SMC website, https://www.smc.eu

113
Plug-in Connector Connecting Base SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported

q Series y Pilot valve option !1 A, B port size


3 SY3000 — Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K∗1 High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗1 Only the metal seal type is available for the 01 1/8 SY5000
high pressure type. 02 1/4 SY7000

w Type of actuation u Coil type One-touch fitting (Metric)


1 Single Symbol A, B port SY3000 SY5000 SY7000
2-position — Standard
2 Double C2 Ø2  — —
T With power saving circuit (Continuous duty type)
3 Closed centre C3 Ø 3.2  — —
∗ Be sure to select the power saving circuit
4 3-position Exhaust centre C4 Ø4   —
type if the valve is to be continuously
5 Pressure centre energised for long periods of time. C6 Ø6   
A∗1 N.C./N.C. ∗ Be careful of the energising time when the C8 Ø8 —  
4-position C10 
B∗1 dual 3-port
N.O./N.O. power saving circuit is selected. Refer to Ø 10 — —
C∗1 N.C./N.O. page 316 for details. C12 Ø 12 — — 
∗1 Only the rubber seal type is available for the
4-position dual 3-port valve. i Rated voltage One-touch fitting (Inch)
Symbol A, B port SY3000 SY5000 SY7000
5 24 VDC
N1 Ø 1/8"  — —
N3 Ø 5/32"   —
e Seal type o Light/surge voltage suppressor N7 Ø 1/4"   
N9 Ø 5/16" —  
0 Rubber seal and common specification
N11 Ø 3/8" — — 
1 Metal seal Surge voltage Common
Symbol With light
suppressor specification
R —
r Pilot type U 
Non-polar
!2 Thread type
S — Positive — Rc
— Internal pilot 
Z  common F G
R External pilot
NS — Negative N NPT
NZ  common T NPTF
∗ For the non-polar type, be careful of surge ∗ Only — is available for M5.
t Back pressure check valve voltage intrusion.
Refer to page 317 for details.
(Built-in valve type) ∗ Select “Z” or “NZ” for models with a power

H
None
Built-in
saving circuit. Select “R,” “U,” “S,” or “Z” for
the valve when the SI unit specification is A2
!3 Type of mounting screw
— Round head combination screw
∗ Only the rubber seal type is available. A (positive common). Select “R,” “U,” “NS,” or
manifold installed type is available if a back “NZ” for the valve when the SI unit B Hexagon socket head cap screw
pressure check valve with a metal seal is specification is A2N (negative common). K Round head combination screw (Drop prevention type)
required. Refer to page 236 for ordering H Hexagon socket head cap screw (Drop prevention type)
examples. However, it is not recommended to ∗ For “K” and “H,” the valve body cover has a
use the built-in valve type and the manifold
installed type at the same time because it will
!0 Manual override drop prevention construction to stop the
mounting screws from falling out when the
reduce the flow. —: D: valve is removed for maintenance, etc.
∗ The built-in valve type back pressure check Non-locking Push-turn ∗ When ordering a valve individually, the
valve is not available for the 3-position type push type locking slotted base gasket is not included.
or the SY7000. type Since the base gasket is attached to the
manifold, please order the base gasket
separately if it is needed for maintenance.
Refer to page 222 for base gasket and
mounting screw part numbers.
∗ “B” and “H” cannot be selected for the
E: F: individual SUP/EXH spacer assembly or
Push-turn Slide locking interface regulator.
locking lever type
type

∗ Refer to page 36 for the safety slide locking


manual override.

Protective class
class # (Mark: )
114
Plug-in Connector Connecting Base
Type 10
Side Ported EX600

SY3000/5000/7000 Series
Type 11
Bottom Ported

RoHS
How to Order Manifolds

Refer to pages 180 (SY5000) and


SS5Y 3 10 S6 Q 2 05 U C6
181 (SY7000) for the dimensions
of Type 11/Bottom-ported type. q w e r t y u i o
q Series t I/O unit stations o Mounting and Option
3 SY3000 — None Option
Symbol Mounting
5 SY5000 1 1 station Name plate Station number


7 SY7000 — — —
Direct
9 9 stations AA  
mounting
∗ When not selecting an SI unit, the symbol will BA  —
w Type be “—.” D — —
∗ SI unit is not included in I/O unit stations. DIN rail
10 Side ported A  
∗ When I/O unit is selected, it is shipped mounting
11 Bottom ported∗1 B  —
separately, and assembled by users. Refer to
∗1 The SY5000 manifold base is used for the the attached operation manual for mounting. ∗ Enter the number of stations inside  when it
bottom-ported SY3000. When ordering, is larger than the number of valve stations.
refer to the “Plug-in Manifold Mixed (Refer to “DIN Rail Option” below.)
Mounting Type” (from page 185). ∗ Only direct mounting is available for the type
y Valve stations 11 bottom-ported type.
e SI unit Symbol Stations Note
∗ Refer to page 319 for the fixation of DIN rail
mounting type manifold.
0 Without SI unit 02 2 stations DIN Rail Option
Q DeviceNet™ (Version A) Double wiring∗1

N PROFIBUS DP (Version A) — Standard length


16 16 stations
V CC-Link 0 Without DIN rail (with bracket)
02 2 stations
ZE EtherNet/IP™ (1 port) Specified layout∗2 3 For 3 stations

Specify a longer rail than the


(Up to 32 solenoids available)


EA EtherNet/IP™ (2 ports) 24 24 stations total length of specified stations.
D EtherCAT 24 For 24 stations
∗1 Double wiring: 2-position single, double,
F PROFINET ∗ If the DIN rail must be mounted without an SI
3-position, and 4-position valves can be
unit, select D0. Then, refer to L3 of the
FA PROFINET (IO-Link master) used on all manifold stations.
dimensions for the DIN rail length and order
WE EtherNet/IP™ compatible wireless base∗1 Use of a 2-position single solenoid will
separately. (Refer to page 227 for the DIN
WF PROFINET compatible wireless base∗1 result in an unused control signal. If this is
rail part number.)
not desired, order with a specified layout.
WS Wireless remote∗1
∗2 Specified layout: Indicate the wiring
∗1 The wireless system is suitable for use only specifications on the manifold specification
in a country where it is in accordance with the sheet. (Note that 2-position double,
Radio Act and regulations of that country. 3-position, and 4-position valves cannot be
∗ I/O unit cannot be mounted without SI unit. used where single wiring has been
∗ Valve plate which connects manifold and SI specified.)
unit is included, but it is not mounted to a ∗ This also includes the number of the blanking
valve without SI unit. For mounting, refer to plate assembly.
the EX600 series in the Web Catalogue.

r SI unit output polarity, end plate type u P, E port entry, SUP/EXH block assembly
M12 M12 power supply connector Internal Internal pilot, External
7/8 inch P, E port entry
power supply IN/OUT, A-coded pilot Built-in silencer pilot
power supply
SI unit output polarity connector Pin Pin U side (2 to 10 stations) U C G
connector
B-coded
(EX600-ED3) arrangement 1 arrangement 2 D side (2 to 10 stations) D E H
(EX600-ED2) (EX600-ED4) (EX600-ED5) Both sides (2 to 24 stations) B F J
Without SI unit — ∗ 3/5(E) port is plugged for the built-in silencer type.
SI unit positive common 2 3 6 8 ∗ When the built-in silencer type is used, keep the exhaust port from
SI unit negative common 4 5 7 9 coming into direct contact with water or other liquids.
∗ Ensure a match with the common specification of the valve to be used.
∗ When not selecting an SI unit, the symbol will be “—.”
Refer to the page on the right for i.

For details on the EX 6 0 0 Integrated Type (For Input/Output) Serial


Transmission System, refer to the Web Catalogue and the Operation
Manual. For the part numbers of the SI units to be mounted, refer to page
2 1 1 . (IP 4 0 specifications may be required according to the I/O unit to be
selected.) Please download the Operation Manual via the SMC website,
https://www.smc.eu

115
Plug-in Connector Connecting Base SY3000/5000/7000 Series

i A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)


Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 Ø2  — — — — N1 Ø 1/8"  — — — —
C3 Ø 3.2  — — — — N3 Ø 5/32"   —  —

Straight
C4 Ø4   —  — N7 Ø 1/4"     
Straight

C6 Ø6      N9 Ø 5/16" —    
C8 Ø8 —     N11 Ø 3/8" — —  — 
C10 Ø 10 — —  —  CM∗1 Straight port, mixed sizes     
C12 Ø 12 — —  —  LN3 Ø 5/32"  — — — —

Upward
CM∗1 Straight port, mixed sizes      LN7 Ø 1/4"   — — —
L4 Ø4   — — — LN9 Ø 5/16" —  — — —
L6 Ø6    — — LN11 Ø 3/8" — —  — —
Upward

Elbow∗2

L8 Ø8 —   — — BN3 Ø 5/32"  — — — —
Downward

L10 Ø 10 — —  — — BN7 Ø 1/4"   — — —


L12 Ø 12 — —  — — BN9 Ø 5/16" —  — — —
Elbow∗2

B4 Ø4   — — — BN11 Ø 3/8" — —  — —
Downward

B6 Ø6    — — Elbow port, mixed sizes


LM∗1 (Including upward and    — —
B8 Ø8 —   — — downward piping)

B10 Ø 10 — —  — — P, E port size Ø


Ø 3/8" Ø 1/2" Ø 3/8" Ø 1/2"
B12 Ø 12 — —  — — (One-touch fittings) 5/16"
Elbow port, mixed sizes
LM∗1 (Including upward and    — —
downward piping)

P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).

How to Order Manifold Assembly

Example (SS5Y3-10S6-) SS5Y3-10S6Q72-05B-C6 ··· 1 set (Type 10 5-station manifold base part no.)
∗SY3100-5U1 ······················· 3 sets (2-position single part no.)
∗SY3200-5U1 ······················· 2 sets (2-position double part no.)
Digital input unit Digital output unit 2-position single ∗EX600-DXPD ····················· 1 set I/O unit part number (Station 1)
EX600-DXPD EX600-DYPB SY3100-5U1 (3 sets) ∗EX600-DYPB ····················· 1 set I/O unit part number (Station 2)
End plate∗1 SI unit∗1 2-position double The asterisk denotes the symbol for the assembly.
EX600-ED4 EX600-SDN1A SY3200-5U1 (2 sets) Prefix it to the part numbers of the valve, etc.
0 1 • For the valve arrangement, the valve closest to the D side is considered the
1st station.
2 3
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A • Under the manifold part number, state the valves to be mounted, then the I/O units in
D side
PWR
OUT U side order starting with the 1st station as shown in the figure above. If the arrangement
0 1
4 5 becomes too complicated, specify the details on a manifold specification sheet.
2 3 12 B 12 B 12 B 12 B 12 B
PCI
BUS BUS
IN OUT
∗1 Do not enter the SI unit part number and the end plate part number
8 7
together.
∗ When mixing top-ported configurations, select from those listed on page
1 2 3 4 5 Valve stations 126.
1 2 I/O unit stations
In such cases, use caution as there is also output on the A and B ports on
the base side.
Specify on the manifold specification sheet if plugs are required for the A
and B ports on the base side.

Protective class
class # (Mark: )
116
SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

q Series y Pilot valve option !0 Manual override


3 SY3000 — Standard (0.7 MPa) —: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K∗1 High pressure type (1.0 MPa) push type locking
∗1 Only the metal seal type is available for the slotted
high pressure type. type

w Type of actuation
1
2-position
Single u Coil type E: F:
2 Double — Standard Push-turn Slide locking
3 Closed centre T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit lever
5 Pressure centre type if the valve is to be continuously type
A∗1 N.C./N.C. energised for long periods of time.
B∗1
4-position
N.O./N.O. ∗ Be careful of the energising time when the
dual 3-port power saving circuit is selected. Refer to
C∗1 N.C./N.O.
page 316 for details. ∗ Refer to page 36 for the safety slide locking
∗1 Only the rubber seal type is available for the manual override.
4-position dual 3-port valve.
i Rated voltage
5 24 VDC

e Seal type !1 Type of mounting screw


— Round head combination screw
0
1
Rubber seal
Metal seal
o Light/surge voltage suppressor B Hexagon socket head cap screw
and common specification K Round head combination screw (Drop prevention type)
Surge voltage Common H Hexagon socket head cap screw (Drop prevention type)
Symbol With light ∗ For “K” and “H,” the valve body cover has a
suppressor specification
r Pilot type R —
Non-polar
drop prevention construction to stop the
mounting screws from falling out when the
— Internal pilot U 
valve is removed for maintenance, etc.
R External pilot S — Positive ∗ When ordering a valve individually, the

Z  common base gasket is not included.
NS — Negative Since the base gasket is attached to the
NZ  common manifold, please order the base gasket
t Back pressure check valve ∗ For the non-polar type, be careful of surge
separately if it is needed for maintenance.
(Built-in valve type) Refer to page 222 for base gasket and
voltage intrusion. Refer to page 317 for
mounting screw part numbers.
— None details.
∗ “B” and “H” cannot be selected for the
H Built-in ∗ Select “R,” “U,” “S,” or “Z” for the valve when
individual SUP/EXH spacer assembly,
∗ Only the rubber seal type is available. A the SI unit output polarity is positive common.
interface regulator, or double check spacer
manifold installed type is available if a back Select “R,” “U,” “NS,” or “NZ” for the valve
assembly with residual pressure release
pressure check valve with a metal seal is when the SI unit output polarity is negative
valve.
required. Refer to page 236 for ordering common.
examples. However, it is not recommended ∗ Only “Z” and “NZ” types are available with a
to use the built-in valve type and the manifold power saving circuit.
installed type at the same time because it will
reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.

Protective class
class # (Mark: )
117
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY3000 Series Connector Connecting Base EX600 (M12 Connector)

2
4 U C2 One-touch fitting
SS5Y3-10S6 - Stations D - C3, N1 ( )
C4, N3 D
6
7 [4(A), 2(B) port]
8 B C6, N7
Applicable tube O.D.: Ø 2
9
: Ø 3.2, Ø 1/8"
(Station 1)---(Station n)
11.5

: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
8

1 P 1 P

63.1
56.6

13.2

3/5 E 2 B2 B2 B2 B2 B 3/5 E

40.2
21.6
4 A4 A4 A4 A4 A

18
10.6
13.6
(For DIN rail
mounting)

7.5

One-touch fitting
(Pitch)
11.8

[1(P), 3/5(E) port] 18.3 15.5 P = 10.5 (17.8)


Applicable tube O.D.: Ø 8, Ø 5/16"

D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override∗1
(L5) L1
DIN rail
holding screw 5.5 L6 L2 ( Push-turn locking slotted type:
Press, then rotate it. )
(For DIN 47 8 DIN rail holding screw 1.5 4(A) port side
Communication connector
rail mounting) (For DIN rail mounting) : Blue (For rubber seal)
2 x M4 mounting hole : Grey (For metal seal)
Power Light/surge 2(B) port side : Yellow 85.1
connector Marker groove
voltage suppressor

0 1
5.5

B A B A B A B A B A
2 3

92.6
14 A 14 A 14 A 14 A 14 A
35

83
106

PWR
90

OUT
60.5

0 1
4 5
40.9

2 3
4.6

BUS PCI BUS


12 B 12 B 12 B 12 B 12 B
8
IN OUT

8 7
8

4.6
1.7
)
C6: 3.6
N7: 7.4
(4.9)

FE 86.6
terminal 5.4 4 x M4 mounting hole
(

End plate (Fitting for the type with P/E


Digital input unit ports on the U and/or D sides)
Valve plate
Input connector
SI unit
Output connector
Digital output unit Connector for handheld terminal

L1 = 10.5 x n1 + 135.5 + 47 x n2 ∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
L2 = 10.5 x n1 + 42 ∗ These figures show the “SS5Y3-10S6Q22-05D-C6.”
L4 = L3 – 10.5 ∗ Refer to page 182 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 47 x n2 + 82
n1: Valve stations
n2: I/O unit stations
L3: DIN Rail Overall Length
Valve
stations
I/O (n1)
unit 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423
1 235.5 248 248 260.5 273 285.5 298 310.5 323 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5 448 448 460.5
2 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 410.5 423 435.5 448 460.5 473 485.5 485.5 498 510.5
3 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5 448 448 460.5 473 485.5 498 510.5 510.5 523 535.5 548 560.5
4 373 385.5 398 410.5 410.5 423 435.5 448 460.5 473 473 485.5 498 510.5 523 535.5 548 548 560.5 573 585.5 598 610.5
5 423 435.5 448 448 460.5 473 485.5 498 510.5 510.5 523 535.5 548 560.5 573 573 585.5 598 610.5 623 635.5 635.5 648
6 473 473 485.5 498 510.5 523 535.5 535.5 548 560.5 573 585.5 598 610.5 610.5 623 635.5 648 660.5 673 673 685.5 698
7 510.5 523 535.5 548 560.5 573 573 585.5 598 610.5 623 635.5 635.5 648 660.5 673 685.5 698 698 710.5 723 735.5 748
8 560.5 573 585.5 598 598 610.5 623 635.5 648 660.5 673 673 685.5 698 710.5 723 735.5 735.5 748 760.5 773 785.5 798
9 610.5 623 635.5 635.5 648 660.5 673 685.5 698 698 710.5 723 735.5 748 760.5 760.5 773 785.5 798 810.5 823 835.5 835.5
118
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY3000 Series Connector Connecting Base EX600 (7/8 Inch Connector)

U C2
SS5Y3-10S6 35 - Stations D - C3, N1 ( )
C4, N3 D One-touch fitting
B C6, N7
[4(A), 2(B) port]
Applicable tube O.D.: Ø 2
: Ø 3.2, Ø 1/8"
11.5

: Ø 4, Ø 5/32"
(Station 1)---(Station n)
: Ø 6, Ø 1/4"
8

1 P 1 P

63.1
56.6

13.2

3/5 E 2 B2 B2 B2 B2 B 3/5 E

40.2
21.6
4 A4 A4 A4 A4 A

18
10.6
13.6
(For DIN rail

7.5
mounting)

One-touch fitting (Pitch)


11.8

[1(P), 3/5(E) port] 18.3 15.5 P = 10.5 (17.8)


Applicable tube O.D.: Ø 8, Ø 5/16"

D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5)
(L5) L1 Manual override∗1

DIN rail
holding screw
5.5 L6 L2 ( Push-turn locking slotted type:
Press, then rotate it. )
Communication connector 47 8 DIN rail holding screw 1.5 4(A) port side
(For DIN (For DIN rail mounting) : Blue (For rubber seal)
rail mounting) 2 x M4 mounting hole
Light/surge : Grey (For metal seal)
Marker groove 2(B) port side : Yellow
voltage suppressor

0 1
5.5

B A B A B A B A B A
2 3

92.6
14 A 14 A 14 A 14 A 14 A
35

83
106
90

60.5
0 1
4 5
40.9

PWR
2 3
4.6

BUS PCI BUS


12 B 12 B 12 B 12 B 12 B
8
53
IN OUT

8 7
8

4.6
1.7
)
C6: 3.6
N7: 7.4
(4.9)

FE 36.7
terminal 5.4 4 x M4 mounting hole
(

End plate Power connector


(Fitting for the type with P/E
Digital input unit ports on the U and/or D sides)
Valve plate
Input connector
Output connector SI unit

∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
L1 = 10.5 x n1 + 152 + 47 x n2 ∗ These figures show the “SS5Y3-10S6Q32-05D-C6.”
L2 = 10.5 x n1 + 42 ∗ Refer to page 182 for dimensions of A or B port top-ported type.
L4 = L3 – 10.5
L5 = (L3 – L1)/2
L6 = 47 x n2 + 82
n1: Valve stations
n2: I/O unit stations
L3: DIN Rail Overall Length
Valve
stations
I/O (n1)
unit 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 198 210.5 223 235.5 248 260.5 260.5 273 285.5 298 310.5 323 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5
1 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 360.5 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5
2 298 310.5 323 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5 448 448 460.5 473 485.5 498 510.5 523 523
3 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548 548 560.5 573
4 385.5 398 410.5 423 435.5 448 448 460.5 473 485.5 498 510.5 510.5 523 535.5 548 560.5 573 585.5 585.5 598 610.5 623
5 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548 548 560.5 573 585.5 598 610.5 610.5 623 635.5 648 660.5 673
6 485.5 498 510.5 510.5 523 535.5 548 560.5 573 573 585.5 598 610.5 623 635.5 648 648 660.5 673 685.5 698 710.5 710.5
7 535.5 548 548 560.5 573 585.5 598 610.5 610.5 623 635.5 648 660.5 673 673 685.5 698 710.5 723 735.5 735.5 748 760.5
8 573 585.5 598 610.5 623 635.5 635.5 648 660.5 673 685.5 698 710.5 710.5 723 735.5 748 760.5 773 773 785.5 798 810.5
9 623 635.5 648 660.5 673 673 685.5 698 710.5 723 735.5 735.5 748 760.5 773 785.5 798 798 810.5 823 835.5 848 860.5
119
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY5000 Series Connector Connecting Base EX600 (M12 Connector)

2
4 One-touch fitting
U C4, N3
SS5Y5-10S6 - Stations D - C6, N7 (D) 6
7
[4(A), 2(B) port]
8 B C8, N9 Applicable tube O.D.: Ø 4, Ø 5/32"
9 : Ø 6, Ø 1/4"
(Station 1)----------(Station n) : Ø 8, Ø 5/16"
11.5

1 P 1 P

73.2
2 B2 B2 B2 B2 B
56.6

13.2

33.4
3/5 E 3/5 E

29.1
4 A4 A4 A4 A4 A

12.4
14.1
8.7
7.5

One-touch fitting
(For DIN rail
mounting)

[1(P), 3/5(E) port] (Pitch)


11.8

Applicable tube O.D.: Ø 10, Ø 3/8" 20 18 P = 16 (20.5)

D side U side
L3
5.3 L4 Manual override∗1
(DIN rail mounting hole pitch: 12.5)

DIN rail
(L5) L1 ( Push-turn locking slotted type:
Press, then rotate it. )
L6 L2 4(A) port side
holding screw 5.5 : Blue (For rubber seal)
(For DIN Communication connector DIN rail holding screw
47 8 1.5 : Grey (For metal seal)
rail mounting) (For DIN rail mounting) 2(B) port side : Yellow
2 x M4 mounting hole
Power
connector Marker groove Light/surge voltage suppressor 85.1
DIN rail
0 1

BA BA BA BA BA 5.5
2 3
35
14 A 14 A 14 A 14 A 14 A

97.5
113.4
90

PWR
OUT
0 1
4 5
2 3
BUS
PCI
BUS 8
IN OUT
5.5
7.4

12 B 12 B 12 B 12 B 12 B
8 7
61.7
81.2
15.4

10.9
4.7
(5.9)
(8.3)

FE terminal 5.4 86.6


End plate
Digital input unit 4 x M5 mounting hole
Valve plate (Fitting for the type with P/E
Input connector
SI unit ports on the U and/or D sides)
Output connector
Connector for handheld terminal
Digital output unit

L1 = 16 x n1 + 141.5 + 47 x n2 ∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
L2 = 16 x n1 + 48 ∗ These figures show the “SS5Y5-10S6Q22-05D-C8.”
L4 = L3 – 10.5 ∗ Refer to page 183 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 47 x n2 + 81.5
n1: Valve stations
n2: I/O unit stations
L3: DIN Rail Overall Length
Valve
stations
I/O (n1)
unit 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 198 223 235.5 248 273 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 560.5
1 248 260.5 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598
2 298 310.5 323 348 360.5 373 398 410.5 423 435.5 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 623 635.5 648
3 348 360.5 373 398 410.5 423 435.5 460.5 473 485.5 498 523 535.5 548 573 585.5 598 610.5 635.5 648 660.5 685.5 698
4 385.5 410.5 423 435.5 460.5 473 485.5 498 523 535.5 548 573 585.5 598 610.5 635.5 648 660.5 673 698 710.5 723 748
5 435.5 448 473 485.5 498 523 535.5 548 560.5 585.5 598 610.5 635.5 648 660.5 673 698 710.5 723 748 760.5 773 785.5
6 485.5 498 523 535.5 548 560.5 585.5 598 610.5 623 648 660.5 673 698 710.5 723 735.5 760.5 773 785.5 810.5 823 835.5
7 535.5 548 560.5 585.5 598 610.5 623 648 660.5 673 698 710.5 723 735.5 760.5 773 785.5 798 823 835.5 848 873 885.5
8 573 598 610.5 623 648 660.5 673 685.5 710.5 723 735.5 760.5 773 785.5 798 823 835.5 848 873 885.5 898 910.5 935.5
9 623 648 660.5 673 685.5 710.5 723 735.5 748 773 785.5 798 823 835.5 848 860.5 885.5 898 910.5 935.5 948 960.5 973
120
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY5000 Series Connector Connecting Base EX600 (7/8 Inch Connector)

U C4, N3
SS5Y5-10S6 35 - Stations D - C6, N7 (D) One-touch fitting
B C8, N9 [4(A), 2(B) port]
Applicable tube O.D.: Ø 4, Ø 5/32"
(Station 1)----------(Station n) : Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
11.5

1 P 1 P

73.2
2 B2 B2 B2 B2 B
56.6

13.2

33.4
3/5 E 3/5 E

29.1
4 A4 A4 A4 A4 A

8.7
12.4
14.1
(For DIN rail
mounting)
7.5

One-touch fitting (Pitch)


11.8

[1(P), 3/5(E) port] 20 18 P = 16 (20.5)


Applicable tube O.D.: Ø 10, Ø 3/8"

L3
D side U side
5.3 L4
(DIN rail mounting hole pitch: 12.5)
(L5) L1 Manual override∗1

DIN rail
holding screw
5.5 L6 L2 (Push-turn locking slotted type:
Press, then rotate it. )
16.5 2 x M4 mounting hole 47 8 DIN rail holding screw 1.5 4(A) port side
(For DIN : Blue (For rubber seal)
Communication connector (For DIN rail mounting)
rail mounting) : Grey (For metal seal)
Light/surge voltage suppressor
Marker groove 2(B) port side : Yellow
DIN rail
0 1

2 3
BA BA BA BA BA 5.5
35
14 A 14 A 14 A 14 A 14 A
90

97.5
113.4
0 1

PWR
4 5

81.2
2 3

60.4
PCI 8
61.7
BUS BUS
IN OUT
5.5
7.4

12 B 12 B 12 B 12 B 12 B
8 7 10.9
15.4

4.7

36.7
(8.3)

(5.9)

FE terminal 5.4 4 x M5 mounting hole Power connector

End plate (Fitting for the type with P/E


ports on the U and/or D sides)
Digital input unit
Valve plate
Input connector
SI unit
Output connector Connector for handheld terminal
Digital output unit
∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
L1 = 16 x n1 + 158 + 47 x n2
∗ These figures show the “SS5Y5-10S6Q32-05D-C8.”
L2 = 16 x n1 + 48
∗ Refer to page 183 for dimensions of A or B port top-ported type.
L4 = L3 – 10.5
L5 = (L3 – L1)/2
L6 = 47 x n2 + 81.5
n1: Valve stations
n2: I/O unit stations
L3: DIN Rail Overall Length
Valve
stations
I/O (n1)
unit 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 223 235.5 248 273 285.5 298 310.5 335.5 348 360.5 385.5 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 560.5 573
1 260.5 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 560.5 573 585.5 598 623
2 310.5 335.5 348 360.5 373 398 410.5 423 435.5 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 623 635.5 648 660.5
3 360.5 373 398 410.5 423 435.5 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 610.5 635.5 648 660.5 685.5 698 710.5
4 410.5 423 435.5 460.5 473 485.5 498 523 535.5 548 573 585.5 598 610.5 635.5 648 660.5 685.5 698 710.5 723 748 760.5
5 460.5 473 485.5 498 523 535.5 548 560.5 585.5 598 610.5 635.5 648 660.5 673 698 710.5 723 748 760.5 773 785.5 810.5
6 498 523 535.5 548 560.5 585.5 598 610.5 635.5 648 660.5 673 698 710.5 723 735.5 760.5 773 785.5 810.5 823 835.5 848
7 548 560.5 585.5 598 610.5 623 648 660.5 673 698 710.5 723 735.5 760.5 773 785.5 810.5 823 835.5 848 873 885.5 898
8 598 610.5 623 648 660.5 673 685.5 710.5 723 735.5 760.5 773 785.5 798 823 835.5 848 873 885.5 898 910.5 935.5 948
9 648 660.5 673 685.5 710.5 723 735.5 760.5 773 785.5 798 823 835.5 848 860.5 885.5 898 910.5 935.5 948 960.5 973 —
121
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY7000 Series Connector Connecting Base EX600 (M12 Connector)

2 One-touch fitting
4 U C6, N7
SS5Y7-10S6 - Stations D - C8, N9 ( ) 6 [4(A), 2(B) port]
C10, N11 D 7
B C12 (Station 1) (Station n) Applicable tube O.D.: Ø 6, Ø 1/4"
8 : Ø 8, Ø 5/16"
9 : Ø 10, Ø 3/8"
: Ø 12
11.5

2
8

82.7
1 P 1 P
2 B2 B2 B2 B2 B
(56.6)

56.6
13.2

3/5 E 3/5 E

35.2
31.6
4 A4 A4 A4 A4 A

11.1
14.2
8.7
(For DIN rail

(Pitch)
(10)
mounting)
(14.3)

One-touch fitting 25 20.5 P = 19 (21.7)


[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 12, Ø 1/2"

D side U side
(L3)
(5.3) (L4)
DIN rail holding screw (DIN rail mounting hole pitch: 12.5)
Manual override∗1
(L5) (For DIN rail mounting) L1
5.5 L6 L2 ( Push-turn locking slotted
type: Press, then rotate it. )
2 x M4 mounting hole 47 8 DIN rail holding screw 1.5 4(A) port side
Power Communication connector (For DIN rail mounting) : Blue (For rubber seal)
connector : Grey (For metal seal)
Marker groove Valve plate Light/surge voltage suppressor 2(B) port side: Yellow 85.1
(DIN rail)
0 1

(5.5)
B A B A B A B A B A
2 3
14 A 14 A 14 A 14 A 14 A
(35)
90

PWR

128.8
OUT

115
0 1
4 5
2 3
96.7
PCI
FE BUS
IN
BUS
OUT
(8)
(77.1)

terminal
8 7
12 B 12 B 12 B 12 B 12 B
5.5
30.8
22.8

5.4
8.8
3.9
(6)

SI unit
(9.3)

86.6
(17.9)

(A, B port: Ø 12) 4 x M5 mounting hole


End plate Connector for (Fitting for the type with P/E
handheld terminal ports on the U and/or D sides)
Digital input unit Digital output unit

Input connector Output connector

L1 = 19 x n1 + 149.7 + 47 x n2 ∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
L2 = 19 x n1 + 56 ∗ These figures show the “SS5Y7-10S6Q22-05D-C10.”
L3 = DIN rail dimension ∗ Refer to page 184 for dimensions of A or B port top-ported type.
L4 = L3 – 10.5
L5 = (L3 – L1)/2
L6 = 47 x n2 + 81.7
n1: Valve stations
n2: I/O unit stations

L3: DIN Rail Overall Length


Valve
I/O stations
unit (n1) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 223 235.5 260.5 273 298 310.5 335.5 348 373 385.5 410.5 423 448 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5
1 260.5 285.5 298 323 335.5 360.5 373 398 410.5 435.5 448 473 498 510.5 535.5 548 573 585.5 610.5 623 648 660.5 685.5
2 310.5 335.5 348 373 385.5 410.5 423 448 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5 648 673 685.5 710.5 723
3 360.5 373 398 410.5 435.5 448 473 485.5 510.5 523 548 573 585.5 610.5 623 648 660.5 685.5 698 723 735.5 760.5 773
4 410.5 423 448 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5 798 823
5 448 473 485.5 510.5 523 548 560.5 585.5 598 623 648 660.5 685.5 698 723 735.5 760.5 773 798 810.5 835.5 848 873
6 498 523 535.5 560.5 573 598 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5 798 823 835.5 860.5 873 898 923
7 548 560.5 585.5 598 623 635.5 660.5 673 698 723 735.5 760.5 773 798 810.5 835.5 848 873 885.5 910.5 923 948 960.5
8 598 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5 798 823 835.5 860.5 873 898 910.5 935.5 948 973 — —
9 635.5 660.5 673 698 710.5 735.5 748 773 798 810.5 835.5 848 873 885.5 910.5 923 948 960.5 985.5 — — — —
122
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY7000 Series Connector Connecting Base EX600 (7/8 Inch Connector)

U C6, N7
SS5Y7-10S6 35 - Stations D - C8, N9 ( )
C10, N11 D One-touch fitting
B C12
[4(A), 2(B) port]
(Station 1) (Station n) Applicable tube O.D.: Ø 6, Ø 1/4"
One-touch fitting : Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
[1(P), 3/5(E) port] : Ø 12
Applicable tube O.D.: Ø 12, Ø 1/2"
11.5

2
8

82.7
1 P 1 P
2 B2 B2 B2 B2 B
(56.6)

56.6
13.2

8.7
3/5 E 3/5 E

35.2
31.6
4 A4 A4 A4 A4 A

11.1
14.2
(For DIN rail

(Pitch)
(10)
mounting)
(14.3)

25 20.5 P = 19 (21.7)

DIN rail holding screw


D side (For DIN rail mounting) U side
(L3)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L5) L1 Manual override∗1
5.5
16.5 2 x M4 mounting hole
L6
47 8 DIN rail holding screw
L2
1.5
( Push-turn locking slotted
type: Press, then rotate it. )
4(A) port side
Communication connector (For DIN rail mounting) : Blue (For rubber seal)
Light/surge voltage suppressor : Grey (For metal seal) Power connector
Marker groove
(DIN rail) 2(B) port side: Yellow

0 1

(5.5)
B A B A B A B A B A
2 3
(35)
14 A 14 A 14 A 14 A 14 A
90

128.8
115
0 1
4 5

PWR
2 3
96.7
PCI
FE BUS
IN
BUS
OUT (8)
(77.1)

terminal
8 7
75.8
5.5

12 B 12 B 12 B 12 B 12 B
31
22.8

5.4
8.8
3.9

End plate
(6)
(9.3)

36.7
(17.9)

Digital input unit (A, B port: Ø 12) 4 x M5 mounting hole

Input connector Valve plate (Fitting for the type with P/E
ports on the U and/or D sides)
Output connector SI unit
Digital output unit Connector for
handheld terminal
L1 = 19 x n1 + 166.2 + 47 x n2
L2 = 19 x n1 + 56
L4 = L3 – 10.5 ∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
L5 = (L3 – L1)/2 ∗ These figures show the “SS5Y7-10S6Q32-05D-C10.”
L6 = 47 x n2 + 81.7 ∗ Refer to page 184 for dimensions of A or B port top-ported type.
n1: Valve stations
n2: I/O unit stations

L3: DIN Rail Overall Length


Valve
I/O stations
unit (n1) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 235.5 248 273 285.5 310.5 323 348 360.5 385.5 410.5 423 448 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5 648
1 285.5 298 323 335.5 360.5 373 398 410.5 435.5 448 473 485.5 510.5 523 548 560.5 585.5 598 623 635.5 660.5 685.5 698
2 323 348 360.5 385.5 398 423 435.5 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5 648 673 685.5 710.5 723 748
3 373 398 410.5 435.5 448 473 485.5 510.5 523 548 560.5 585.5 598 623 635.5 660.5 673 698 710.5 735.5 760.5 773 798
4 423 435.5 460.5 473 498 510.5 535.5 560.5 573 598 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5 798 823 835.5
5 473 485.5 510.5 523 548 560.5 585.5 598 623 635.5 660.5 673 698 710.5 735.5 748 773 785.5 810.5 835.5 848 873 885.5
6 510.5 535.5 548 573 585.5 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5 798 823 835.5 860.5 873 898 910.5 935.5
7 560.5 585.5 598 623 635.5 660.5 673 698 710.5 735.5 748 773 785.5 810.5 823 848 860.5 885.5 910.5 923 948 960.5 985.5
8 610.5 623 648 660.5 685.5 710.5 723 748 760.5 785.5 798 823 835.5 860.5 873 898 910.5 935.5 948 973 985.5 — —
9 660.5 673 698 710.5 735.5 748 773 785.5 810.5 823 848 860.5 885.5 898 923 935.5 960.5 985.5 — — — — —
123
124
Plug-in Connector Connecting Base
EX600
Type 12
SY3000/5000/7000 Series
®

Top Ported
RoHS
How to Order Manifolds

SS5Y 3 12S6 Q 2 05 U
Refer to pages 182 to 184
for the dimensions of
Type 12/Top-ported type. q w e r t y u i
q Series e SI unit output polarity, end plate type t Valve stations
3 SY3000 M12 7/8 inch
M12 power supply connector Symbol Stations Note
power supply IN/OUT, A-coded
5 SY5000 SI unit output polarity connector power supply
Pin Pin
02 2 stations
connector
Double wiring∗1

···
B-coded

···
7 SY7000
(EX600-ED2) (EX600-ED3) arrangement 1 arrangement 2
(EX600-ED4) (EX600-ED5)
16 16 stations
Without SI unit —
02 2 stations
SI unit positive common 2 3 6 8 Specified layout∗2

···

···
SI unit negative common 4 5 7 9 (Up to 32 solenoids available)
24 24 stations
∗ When not selecting an SI unit, the symbol will be “—.”
∗1 Double wiring: 2-position single, double,
w SI unit ∗ Ensure a match with the common specification of the valve to be used.
3-position, and 4-position valves can be
used on all manifold stations.
Q
0 Without SI unit
DeviceNet™ (Version A)
r I/O unit stations Use of a 2-position single solenoid will result
— None in an unused control signal. If this is not
N PROFIBUS DP (Version A) desired, order with a specified layout.
V CC-Link 1 1 station
∗2 Specified layout: Indicate the wiring
···

···

ZE EtherNet/IP™ (1 port) specifications on the manifold specification


EA EtherNet/IP™ (2 ports) 9 9 stations sheet. (Note that 2-position double,
D EtherCAT ∗ When not selecting an SI unit, the symbol will be “—.” 3-position, and 4-position valves cannot be
∗ SI unit is not included in I/O unit stations. used where single wiring has been
F PROFINET
∗ When I/O unit is selected, it is shipped specified.)
FA PROFINET (IO-Link master) separately, and assembled by users. Refer to ∗ This also includes the number of the blanking
WE EtherNet/IP™ compatible wireless base∗1 the attached operation manual for mounting. plate assembly.
WF PROFINET compatible wireless base∗1
WS Wireless remote∗1 y P, E port entry, SUP/EXH block assembly
∗1 The wireless system is suitable for use only in a country where it is in Internal pilot,
accordance with the Radio Act and regulations of that country. P, E port entry Internal pilot External pilot
Built-in silencer
∗ I/O unit cannot be mounted without SI unit.
∗ Valve plate which connects manifold and SI unit is included, but it is not mounted to a
U side (2 to 10 stations) U C∗1 G
valve without SI unit. For mounting, refer to the EX600 series in the Web Catalogue. D side (2 to 10 stations) D E∗1 H
Both sides (2 to 24 stations) B — J
How to Order Manifold Assembly ∗1 For SUP/EXH block assembly specifications, built-in silencer types will
have P port entry stipulated.
∗ The P and E ports are only available on the U and D sides for the built-in silencer type. 3/5(E) port is
Example (SS5Y3-12S6-) plugged. The silencer exhaust port is located on the opposite side of the P and E port entry.
(Example: When the P and E port entry is on the D side, the silencer exhaust port is on the U side.)
Digital input unit Digital output unit 2-position single ∗ When the built-in silencer type is used, keep the exhaust port from
EX600-DXPD EX600-DYPB SY3130-5U1-C6 (3 sets) coming into direct contact with water or other liquids.
End plate∗1 SI unit∗1
EX600-ED4 EX600-SDN1A
2-position double
SY3230-5U1-C6 (2 sets) u P, E port size (One-touch fittings)
0 1
Symbol SY3000 SY5000 SY7000
PE
X
PE
X — Ø8 Ø 10 Ø 12
3/5E B A B A B A B A B A 3/5E
2 3 4A 4A 4A 4A 4A

D side
PWR
OUT U side N Ø 5/16" Ø 3/8" Ø 1/2"
0 1
4 5
2 3
PCI
1P
2B 2B 2B 2B 2B
1P ∗ For N, sizes are in inches.
BUS BUS

i Mounting
IN OUT

8 7

1 2 3 4 5 Valve stations — Direct mounting


1 2 I/O unit stations D DIN rail mounting (With DIN rail)
D0 DIN rail mounting (Without DIN rail)
SS5Y3-12S6Q72-05B ·········· 1 set (Type 12 5-station manifold base part no.) D3 For 3 stations Specify a length longer
∗SY3130-5U1-C6 ················· 3 sets (2-position single part no.)
···

···

than that of the standard


∗SY3230-5U1-C6 ················ 2 sets (2-position double part no.)
D24 For 24 stations rail.
∗EX600-DXPD ······················ 1 set I/O unit part number (Station 1)
∗EX600-DYPB ······················ 1 set I/O unit part number (Station 2) ∗ If the DIN rail must be mounted without an SI unit, select D0. Then,
refer to L3 of the dimensions for the DIN rail length and order
The asterisk denotes the symbol for the assembly. separately. (Refer to page 227 for the DIN rail part number.)
Prefix it to the part numbers of the valve, etc. ∗ Refer to page 319 for the fixation of DIN rail mounting type manifold.
• For the valve arrangement, the valve closest to the D side is considered the 1st station. For details on the EX600 Integrated Type (For Input/Output) Serial
• Under the manifold part number, state the valves to be mounted, then the I/O units in Transmission System, refer to the Web Catalogue and the Operation
order starting with the 1st station as shown in the figure above. If the arrangement Manual. For the part numbers of the SI units to be mounted, refer to page
becomes too complicated, specify the details on a manifold specification sheet. 211. (IP40 specifications may be required according to the I/O unit to be
∗1 Do not enter the SI unit part number and the end plate part number together. selected.) Please download the Operation Manual via the SMC website,
https://www.smc.eu

125
Plug-in Connector Connecting Base SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported

q Series y Pilot valve option !1 A, B port size


3 SY3000 — Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K∗1 High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗1 Only the metal seal type is available for the 01 1/8 SY5000
high pressure type. 02 1/4 SY7000

w Type of actuation u Coil type


One-touch fitting (Metric)
Symbol A, B port SY3000 SY5000 SY7000
1 Single
2-position — Standard C2 Ø2  — —
2 Double
T With power saving circuit (Continuous duty type) C3 Ø 3.2  — —
3 Closed centre
∗ Be sure to select the power saving circuit C4 Ø4   —
4 3-position Exhaust centre
type if the valve is to be continuously C6 Ø6   
5 Pressure centre energised for long periods of time. C8 Ø8 —  
A∗1 N.C./N.C. ∗ Be careful of the energising time when the
4-position C10 Ø 10 — — 
B∗1 N.O./N.O. power saving circuit is selected. Refer to page
dual 3-port
316 for details. C12 Ø 12 — — 
C∗1 N.C./N.O.
∗1 Only the rubber seal type is available for the One-touch fitting (Inch)
4-position dual 3-port valve. i Rated voltage Symbol A, B port SY3000 SY5000 SY7000
N1 Ø 1/8"  — —
5 24 VDC
N3 Ø 5/32"   —
N7 Ø 1/4"   
e Seal type o Light/surge voltage suppressor N9 Ø 5/16" —  
0 Rubber seal N11 Ø 3/8" — — 
1 Metal seal
and common specification
Surge voltage Common
Symbol With light
suppressor specification
R —
Non-polar !2 Thread type
r Pilot type U 
— Rc
— Internal pilot S — Positive
 F G
R External pilot Z  common
N NPT
NS — Negative T NPTF
NZ  common
∗ Only — is available for M5.
∗ Select “R,” “U,” “S,” or “Z” for the valve when
t Back pressure check valve the SI unit output polarity is positive
common. Select “R,” “U,” “NS,” or “NZ” for
— None the valve when the SI unit output polarity is
H Built-in negative common. !3 Type of mounting screw
∗ Only the rubber seal type is available. A ∗ For the non-polar type, be careful of surge — Round head combination screw
manifold installed type is available if a back voltage intrusion. B Hexagon socket head cap screw
pressure check valve with a metal seal is Refer to page 317 for details.
K Round head combination screw (Drop prevention type)
required. Refer to page 236 for ordering ∗ Only “Z” and “NZ” types are available with a
examples. However, it is not recommended power saving circuit. H Hexagon socket head cap screw (Drop prevention type)
to use the built-in valve type and the manifold ∗ For “K” and “H,” the valve body cover has a
installed type at the same time because it will drop prevention construction to stop the
reduce the flow. !0 Manual override mounting screws from falling out when the
∗ The built-in valve type back pressure check valve is removed for maintenance, etc.
valve is not available for the 3-position type
—: D: ∗ When ordering a valve individually, the
Non-locking Push-turn base gasket is not included.
or the SY7000.
push type locking slotted Since the base gasket is attached to the
type manifold, please order the base gasket
separately if it is needed for maintenance.
Refer to page 222 for base gasket and
mounting screw part numbers.
∗ “B” and “H” cannot be selected for the
individual SUP/EXH spacer assembly or
E: F: interface regulator.
Push-turn Slide locking
locking lever type
type

∗ Refer to page 36 for the safety slide locking


manual override.
Protective class
class # (Mark: )
126
Plug-in Connector Connecting Base
Type 10
Side Ported EX245
Type 11
Bottom Ported
SY3000/5000/7000 Series
How to Order Manifold

Side Ported/Bottom Ported SS5Y 3 10 S AAN 05 D C6


Refer to pages 180 (SY5000) and
181 (SY7000) for the dimensions
q w e r t y u i o
of Type 11/Bottom-ported type. Only direct mounting is selectable for the manifold.

q Serie w Type e SI Unit specifications r With or without


3 SY3000 10 Side ported Symbol (output polarity) Communication Communication connector I/O modules
Protocol
5 SY5000 11∗1 Bottom ported Negative common (PNP) connector specifications Without I/O

7 SY7000 ∗1: The SY5000 manifold base is used 0 Without SI Unit module
for the bottom-ported SY3000. Push/Pull Push/Pull
When ordering, refer to the “Plug-
AAN (SCRJ): 2 pcs. (24 V): 2 pcs. Y With I/O module
in Mixed Mounting Type Manifold” PROFINET Push/Pull Push/Pull
ABN
t Number of I/O modules ACN
(RJ45): 2 pcs.
M12: 2 pcs.
(24 V): 2 pcs.
7/8 inch: 2 pcs.
Without I/O module
— (Without SI Unit) ∗: The valve output polarity for the SI unit is negative common (PNP).
1 1 station o A, B port size (Metric)
···

···

10 (Side ported) series 11 (Bottom ported) series


8 8 stations Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000
C2 Ø2  — — — —
y Valve stations (In the case of the 32-output SI Unit) C3 Ø 3.2  — — — —
Symbol Stations Note C4 Ø4   —  —
Straight

02 2 stations C6 Ø6     
Double wiring∗1 C8 Ø8 —    
···

···

16 16 stations C10 Ø 10 — —  — 
02 2 stations Specified layout∗2 C12 Ø 12 — —  — 
CM∗2 Straight port, mixed sizes     
···

···

(Available up to 32
solenoids) L4 Ø4   — — —
24 24 stations
  
Upward

L6 Ø6 — —
∗1: Double wiring: 2-position single, double, 3-position L8 Ø8 —   — —
and 4-position valves can be used on all manifold L10 Ø 10 — —  — —
stations. Use of a 2-position single solenoid will L12 Ø 12 — —  — —
result in an unused control signal. If this is not ∗1
B4 Ø4   — — —
Elbow
Downward

desired, order with a specified layout B6 Ø6    — —


∗2: Specified layout: Indicate the wiring specifications B8 Ø8 —   — —
on the manifold specification sheet. B10 Ø 10 — —  — —
(Note that 2-position double, 3-position and 
B12 Ø 12 — — — —
4-position valves cannot be used where single
Elbow port, mixed sizes
wiring has been specified.) LM    — —
(Including upward and downward piping)
∗3: This also includes the number of blanking plate
P, E port size (One-touch fittings) Ø8 Ø 10 Ø 12 Ø 10 Ø 12
assembly.
A, B port size (Inch)
u P, E port entry 10 (Side ported) series 11 (Bottom ported) series
U U side (2 to 10 stations) Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000
D D side (2 to 10 stations) N1 Ø 1/8"  — — — —
B Both sides (2 to 24 stations) N3 Ø 5/32"   —  —
Straight

N7 Ø 1/4"     
i SUP/EXH block assembly N9 Ø 5/16" —    
N11 Ø 3/8" — —  — 
— Internal pilot
CM∗2 Straight port, mixed sizes     
S Internal pilot, Built-in silencer
LN3 Ø 5/32"  — — — —
Downward Upward

R External pilot
LN7 Ø 1/4"   — — —
∗: 3/5(E) port is plugged for the built-in silencer type. LN9 Ø 5/16" —  — — —
∗: When the built-in silencer type is used, keep LN11 1 Ø 3/8" — —  — —

the exhaust port from coming in direct contact BN3 Ø 5/32"  — — — —
Elbow

with water or other liquids. BN7 Ø 1/4"   — — —


BN9 Ø 5/16" —  — — —
For details about the EX245 Integrated-type (For BN11 Ø 3/8" — —  — —
Input/Output) Serial Transmission System, refer Elbow port, mixed sizes
to the Web Catalogue and the Operation LM    — —
(Including upward and downward piping)
Manual. For details about part numbers of SI P, E port size (One-touch fittings) Ø 5/16" Ø 3/8" Ø 1/2" Ø 3/8" Ø 1/2"
Units to be mounted, refer to pages 204 and 205.
∗1: To avoid interference with the body or piping, select downward elbow port when mounting the
Please download the Operation Manual via SMC
optional spacer assembly (pages 228 to 231).
website, https://www.smc.eu
∗2: When using mixed sizes for the A and B ports, please indicate so on the separate manifold specification sheet.
127
Plug-in Connector Connecting Base SY3000/5000/7000 Series

How to Order Manifold Assembly

Example (SS5Y3-10SAAN-)
2-position double (24 VDC) 3-position closed centre SS5Y3-10SAANY2-05D-C6 ···1 set (Type 10 5-station manifold base part no.)
SY3200-5U1 (1 set) (24 VDC) ∗SY3100-5U1 ···························3 sets (2-position single part no.)
SY3300-5U1 (1 set) ∗SY3200-5U1 ···························1 set (2-position double part no.)
2-position single (24 VDC) ∗SY3300-5U1 ···························1 set (3-position closed centre part no.)
SY3100-5U1 (3 sets) ∗EX245-DX1 ····························1set I/O module part no.
Digital input module ∗EX245-DY1 ····························1set I/O module part no.
EX245-DX1 The asterisk denotes the symbol for assembly.
Digital output module Prefix it to the part numbers of the valve etc.
EX245-DY1
ide
• The valve arrangement is numbered as the 1st station from the D side.
Us
• The I/O module station arrangement is numbered starting from the SI unit side.

ns
io
at
St
2
3 • Under the manifold part number, state the valves to be mounted, then the I/O
1
ide module in order from the 1st station as shown in the figure above. If the
Ds
arrangement becomes complicated, specify on a manifold specification sheet.

SI Unit∗1 ∗1: Do not enter the SI Unit part number and the end plate part number together.
1 ∗: When mixing top ported configurations, select from page 126. In this case,
EX245-SPN1A
use caution as there is also output on the A and B port on base side.
2 End plate∗1 Specify on a manifold specification sheet if plugs are required on the A
s
Sta
tion EX245-EA2-3 and B port on base side.

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

q Serie y Pilot valve option !0 Manual override


3 SY3000 — Standard (0.7 MPa) —: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K∗1 High pressure type (1.0 MPa) push type locking
∗1: Only metal seal type is available for the slotted
w Type of actuation high pressure type. type
1 Single
2-position
2
3
Double
Closed centre
u Coil type
— Standard E: F:
4 3-position Exhaust centre Push-turn Slide locking
T With power saving circuit (Continuous duty type)
5 Pressure centre locking type
∗: Be sure to select the power saving circuit
A∗1 N.C./N.C.
type when the valve is continuously
lever
4-position type
B∗1 dual 3-port
N.O./N.O. energised for long periods of time.
C∗1 N.C./N.O. ∗: Be careful of the energising time when the
∗1: Only rubber seal type is available for the power saving circuit is selected. Refer to
4-position dual 3-port valve. page 316 for details. ∗: Refer to page 36 for with the safety slide
locking manual override.
e Seal type i Rated voltage
0 Rubber seal 5 24 VDC !1 Type of mounting screw
1 Metal seal — Round head combination screw
o Light/surge voltage suppressor B Hexagon socket head cap screw
r Pilot type and common specification K
H
Round head combination screw (Falling-out-prevention type)
Hexagon socket head cap screw (Falling-out-prevention type)
— Internal pilot Surge voltage Common
Symbol With light
suppressor specification ∗: For “K” and “H”, the valve body cover has a
R External pilot
drop prevention construction to stop the
R — mounting screws from falling out when the
t Back pressure check valve U 

Non-polar
valve is removed for maintenance etc.
(Built-in valve type) NS — Negative ∗: When ordering a valve individually, the
— None NZ  common base gasket is not included.
∗: “R" and “U” are applicable for every SI Unit. Since the base gasket is attached to the
H Built-in
manifold, please order the base gasket
∗: Only rubber seal type. Manifold installed type ∗: Only “NZ” types are available for with the
power saving circuit. separately if it is needed for maintenance
is available if the back pressure check valve service.
is required for a valve with metal seal. Refer Refer to page 222 for part numbers of the
to page 236 for Ordering Example. However, base gasket and mounting screw.
it is not recommended to use the built-in ∗: “B” and “H” cannot be selected for the
valve type and the manifold installed type at individual SUP/EXH spacer assembly,
the same time because it will reduce the flow. interface regulator or double check spacer
∗: The built-in valve type back pressure check assembly with residual pressure release
valve is not available for the 3-position type valve.
or the SY7000. Protective class
class # (Mark: )
128
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY3000 Series Connector Connecting Base EX245

U C2,N1 One-touch fitting


SS5Y3-10SA - Stations DB - C3,N3
C4,N7 [4(A), 2(B) port]
C6,CM Applicable tube O.D Ø 2
Ø 3.2
Ø4
Ø6
Ø 1/8"
Ø 5/32"
FE terminal (M4) Ø 1/4"

manual override)
(Slide locking
1 P 1 P

68.8
63.1
61.5

40.2
3/5 E 2 B2 B2 B2 B2 B 3/5 E

21.6
4 A4 A4 A4 A4 A

18
(Pitch)

10.6
13.6
One-touch fitting 18.3 15.5 P = 10.5
[1(P), 3/5(E) port] (17.8)
Applicable tube O.D Ø 8
Ø 5/16"

D side Marker mounting hole U side


Light/surge voltage suppressor
L1 Manual override
5.5
54 54
L3
85
L2
1.5
(Push-turn locking slotted type:
Press, then rotate it. )
3 x M5 4(A) port side : Blue (For rubber seal)
Mounting hole Output Input : Grey (For metal seal)
connector connector SI Unit 2(B) port side : Yellow 90

X0 0 2 X1 X0 0 2 X1

1 3 1 3
B A B A B A B A
X2 4 6 X3 X2 4 6 X3
92.6

14 A 14 A 14 A 14 A
83

83
120

60.5

5 7 5 7
X4 8 10 X5
4.6

12 B 12 B 12 B 12 B

9 11
14.5

X6 12 14 X7
4.6
1.7
C6: 3.6 (4.9)

13 15

4 x M4 Mounting hole
17.5

)
7.5

N7: 7.4

(Fitting for the type with P/E ports


Digital Input Module on the U and/or D sides)
(

Digital Output Module


End plate (Station 1) (Station n)

<SS5Y3-10SACN>

FE terminal (M4) ∗: These figures show the “SS5Y3-10SAANY2-05D-C6”.


∗: Refer to page 177 for dimensions of external pilot, silencer and elbow fittings.
∗: Refer to page 182 for dimensions of A or B port top-ported type.
1 P

3/5 E 2 B2

4 A4

BA
14 A

12
27.7

L3 = 54 x n2 + 113.6
∗ n1 is the valve stations.
Dimensions Formula/L1 = 10.5 x n1 + 167.1 L2 = 10.5 x n1 + 42 ∗ The L1 dimension is the dimension without an I/O module. Add 54 mm to this dimension for each I/O module. n2 is the number of I/O module stations.
Stations n1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 188.1 198.6 209.1 219.6 230.1 240.6 251.1 261.6 272.1 282.6 293.1 303.6 314.1 324.6 335.1 345.6 356.1 366.6 377.1 387.6 398.1 408.6 419.1
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
129
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Type 10/Side Ported

Dimensions: SY5000 Series EX245


One-touch fitting
U C4,N3
SS5Y5-10SA - Stations DB - C6,N7
C8,N9
[4(A), 2(B) port]
CM Applicable tube O.D Ø 4
Ø6
Ø8
Ø 5/32"
Ø 1/4"
FE terminal (M4) Ø 5/16"

manual override)
(Slide locking
78.9
73.2
1 P 1 P
S
61.5

2 B2 B2 B2 B2 B

33.4
3/5 3/5

29.1
E E

4 A4 A4 A4 A4 A

One-touch fitting 20 18 (Pitch)

8.7
12.4
14.1
[1(P), 3/5(E) port] P = 16
Applicable tube O.D Ø 10 (20.5)
Ø 3/8"

D side Marker mounting hole U side


Light/surge voltage suppressor
L1 Manual override
L3 L2
3 x M5
5.5
54 54 85
(Push-turn locking slotted type:
Press, then rotate it. )
Mounting hole 4(A) port side : Blue (For rubber seal) 90
Output Input
: Grey (For metal seal)
connector connector SI Unit
2(B) port side : Yellow
X0 0 2 X1 X0 0 2 X1

1 3 1 3
X2 4 6 X3 X2 4 6 X3 B A B A B A B A
14 A 14 A 14 A 14 A
83

97.5
113.4
120

5 7 5 7
X4 8 10 X5
81.2
5.5

9 11
14.5

X6 12 14 X7 12 B 12 B 12 B 12 B

13 15
10.9
4.7
17.5

7.5

(Station 1) (Station n) 4 x M5 Mounting hole


Digital input module
Digital output module (Fitting for the type with P/E ports
on the U and/or D sides)
End plate

<SS5Y5-10SACN>

∗ These figures show the “SS5Y5-10SAANY2-05D-C8”.


FE terminal (M4) ∗ Refer to page 178 for dimensions of external pilot, silencer and elbow fittings.
∗ Refer to page 183 for dimensions of A or B port top-ported type.

1 P
2 B2

3/5 E

4 A4

BA
14 A

12
27.7

L3 = 54 x n2 + 113.1

∗ n1 is the valve stations.


Dimensions Formula/L1 = 16 x n1 + 173.1 L2 = 16 x n1 + 48 ∗ The L1 dimension is the dimension without an I/O module. Add 54 mm to this dimension for each I/O module. n2 is the number of I/O module stations.
Stations n1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 205.1 221.1 237.1 253.1 269.1 285.1 301.1 317.1 333.1 349.1 365.1 381.1 397.1 413.1 429.1 445.1 461.1 477.1 493.1 509.1 525.1 541.1 557.1
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
130
SY3000/5000/7000 Series
Type 10/Side Ported

Dimensions: SY7000 Series EX245

U C6,N7
SS5Y7-10SA - Stations DB - C8,N9
C10,N11
One-touch fitting
C12,CM [4(A),2(B) port]
Applicable tube O.D C6 : Ø 6
C8 : Ø 8
C10 : Ø 10
C12 : Ø 12
N7 : Ø 1/4"
N9 : Ø 5/16"

(Slide locking manual override)


FE terminal (M4) N11 : Ø 3/8"

85.8
82.7
1 P 1 P
S
2 B2 B2 B2 B2 B
61.5

56.6
35.2
3/5 E 3/5 E

31.6
4 A4 A4 A4 A4 A

(Pitch)

8.7
11.1
14.2
One-touch fitting 25 P = 19
[1(P), 3/5(E) port] 20.5
Applicable tube O.D C12 : Ø 12 (21.7)
N13 : Ø 1/2"
3 x M5 Mounting hole
D side U side
L1
5.5 L3 L2 1.5 Light/surge voltage suppressor
54 54 85
Manual override
Marker Push-turn locking slotted type:
mounting hole (Press, then rotate it. )
Output Input 4(A) port side: Blue (For rubber seal) 90
connector connector SI Unit : Grey (For metal seal)
2(B) port side: Yellow
X0 0 2 X1 X0 0 2 X1

1 3 1 3
B A B A B A B A
X2 4 6 X3 X2 4 6 X3
83

14 A 14 A 14 A 14 A
120

128.8
115

5 7 5 7
X4 8 10 X5
14.5

96.7

9 11
X6 12 14 X7
5.5

12 B 12 B 12 B 12 B

13 15
17.5

7.5

8.8
3.9

(Station 1) (Station n)
End plate Digital input module 4 x M5 Mounting hole
Digital output module (Fitting for the type with P/E ports
on the U and/or D sides)

<SS5Y7-10SACN>

BA
14 A
∗ These figures show the “SS5Y7-10SAANY2-05D-C10”.
∗ Refer to page 179 for dimensions of external pilot, silencer and elbow fittings.
∗ Refer to page 184 for dimensions of A or B port top-ported type.
12 B
27.7

FE terminal (M4)

1 P
2 B2

3/5 E
4 A4

L3 = 54 x n2 + 113.3

∗ n1 is the valve stations.


Dimensions Formula/L1 = 19 x n1 + 181.3 L2 = 19 x n1 + 56 ∗ The L1 dimension is the dimension without an I/O module. Add 54 mm to this dimension for each I/O module. n2 is the number of I/O module stations.
Stations n1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 219.3 238.3 257.3 276.3 295.3 314.3 333.3 352.3 371.3 390.3 409.3 428.3 447.3 466.3 485.3 504.3 523.3 542.3 561.3 580.3 599.3 618.3 637.3
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
131
Plug-in Connector Connecting Base
EX245
Type 12
Top ported
SY3000/5000/7000 Series
How to Order Manifold

Only direct mounting is


Top ported SS5Y 3 12 S AAN 05 D S N selectable for the manifold.

Refer to pages 182 to


184 for dimensions of
q w e r t y u i
Type 12/Top ported type.

q Series w SI Unit specifications


3 SY3000 Symbol (output polarity) Communication connector
Protocol Communication connector
5 SY5000 Negative common (PNP) specifications
7 SY7000 0 Without SI Unit
AAN Push/Pull (SCRJ): 2 pcs. Push/Pull (24 V): 2 pcs.
e With or without I/O modules ABN PROFINET Push/Pull (RJ45): 2 pcs. Push/Pull (24 V): 2 pcs.
— Without I/O module ACN M12: 2 pcs. 7/8 inch: 2 pcs.
Y With I/O module ∗: The valve output polarity for the SI unit is negative common (PNP).

r Number of I/O modules t Valve stations u SUP/EXH block assembly


Without I/O module (In the case of the 32-output SI Unit) — Internal pilot
— (Without SI Unit) Symbol Stations Note S Internal pilot, Built-in silencer
1 1 station 02 2 stations R External pilot
Double wiring∗1
···

···

···

···

∗: 3/5(E) port is plugged for the built-in silencer


8 8 stations 16 16 stations type.The silencer exhaust port is located on
02 2 stations Specified layout∗2 the opposite side of P, E port entry.
y P, E port entry
···

···

(Available up to 32 (Example: When the P, E port entry is D side,


24 24 stations solenoids) the silencer exhaust port is U side.)
U U side (2 to 10 stations) ∗: When the built-in silencer type is used, keep
D D side (2 to 10 stations) ∗1: Double wiring: 2-position single, double,
the exhaust port from coming in direct contact
B Both sides (2 to 24 stations) 3-position and 4-position valves can be used on
with water or other liquids.
all manifold stations. Use of a 2-position single
solenoid will result in an unused control signal. If
For details about the EX245 Integrated-type this is not desired, order with a specified layout i P, E port size
(For Input/Output) Serial Transmission System, ∗2: Specified layout: Indicate the wiring specifications (One-touch fittings)
refer to the Web Catalogue and the Operation on the manifold specification sheet.
Manual. For details about part numbers of SI Symbol SY3000 SY5000 SY7000
(Note that 2-position double, 3-position and
Units to be mounted, refer to pages 213 and 4-position valves cannot be used where single — Ø8 Ø 10 Ø 12
214. Please download the Operation Manual via wiring has been specified.)
SMC website, https://www.smc.eu ∗: This also includes the number of blanking plate N Ø 5/16" Ø 3/8" Ø 1/2"
assembly.

How to Order Manifold Assembly

Example (SS5Y3-12SAAN-)
3-position closed centre SS5Y3-12SAANY2-05DS-N ·····1 set (Type 12 5-station manifold base part no.)
2-position double (24 VDC)
(24 VDC) ∗SY3130-5U1-C6 ·····················3 sets (2-position single part no.)
SY3200-5U1 (1 set)
SY3300-5U1 (1 set) ∗SY3220-5U1-C6 ·····················1 set (2-position double part no.)
2-position single (24 VDC) ∗SY3330-5U1-C6 ·····················1 set (3-position closed centre part no.)
SY3100-5U1 (3 sets) ∗EX245-DX1 ····························1set I/O module part no.
Digital input module ∗EX245-DY1 ····························1set I/O module part no.
EX245-DX1 The asterisk denotes the symbol for assembly.
Digital output module Prefix it to the part numbers of the valve etc.
EX245-DY1
ide
• The valve arrangement is numbered as the 1st station from the D side.
Us
• The I/O module station arrangement is numbered starting from the SI unit side.
ns
io
at
St

2
3 • Under the manifold part number, state the valves to be mounted, then the I/O
1
ide module in order from the 1st station as shown in the figure above. If the
Ds
arrangement becomes complicated, specify on a manifold specification sheet.
∗1: Do not enter the SI Unit part number and the end plate part number
SI Unit∗1
1
together.
EX245-SPN1A
∗: When mixing top ported configurations, select from page 133. In this case, use caution as there
2 End plate∗1 is also output on the A and B port on base side.
s
Sta
tion EX245-EA2-3 Specify on a manifold specification sheet if plugs are required on the A and B port on base side.

132
SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top mounted

q Series y Pilot valve option !1 A, B port size


3 SY3000 — Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K∗1 High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗1: Select the metal seal type for high pressure 01 1/8 SY5000

w Type of actuation type. 02 1/4 SY7000

1 Single One-touch fitting (Metric)


2-position
2 Double Symbol A, B port SY3000 SY5000 SY7000
3 Closed centre u Coil type C2 Ø2  — —
4 3-position Exhaust centre — Standard C3 Ø 3.2  — —
5 Pressure centre With power saving circuit C4 Ø4   —
T (Continuous duty type)∗1∗2   
A∗1 N.C./N.C. C6 Ø6
4-position dual C8  
B∗1 3-port valve
N.O./N.O. ∗1: Be sure to select the power saving circuit Ø8 —
C∗1 N.C./N.O. type when the valve is continuously C10 Ø 10 — — 
∗1: Select the rubber seal type for the 4-position energised for long periods of time. C12 Ø 12 — — 
dual 3-port valve. ∗2: Be careful of the energising time when the One-touch fitting (Inch)
power saving circuit is selected. For details,
refer to page 316. Symbol A, B port SY3000 SY5000 SY7000
N1 Ø 1/8"  — —
e Seal type N3 Ø 5/32" 





N7 Ø 1/4"
0
1
Rubber seal
Metal seal i Rated voltage N9 Ø 5/16" —  
5 24 VDC N11 Ø 3/8" — — 

r Pilot type
— Internal pilot
o Light/surge voltage suppressor !2 Thread type
R External pilot and common specification — Rc
Surge voltage Common F G
With light
suppressor specification N NPT
R — T NPTF
t Back pressure check valve U 

Non-polar
∗: Only — is available for M5.
— None NS — Negative
H∗1 Built-in NZ  common
∗1: Select the rubber seal type when the back
pressure check valve is built-in. Manifold
∗: Select “NZ” for with the power saving circuit. !3 Type of mounting screw
installed type is available if the back — Round head combination screw
B Hexagon socket head cap screw
pressure check valve is required for a valve
with metal seal. For ordering example, refer !0 Manual override Round head combination screw
K (Falling-out-prevention type)∗1
to page 236. However, it is not —: D:
recommended to use the built-in valve type Non-locking Push-turn Hexagon socket head cap screw
and the manifold installed type at the same push locking
H (Falling-out-prevention type)∗1
time because it will reduce the flow. (slotted) ∗1: For “K” and “H”, the valve body cover has a
∗: The built-in valve type back pressure check drop prevention construction to stop the
valve is not available for the 3-position type or mounting screws from falling out when the
the SY7000. valve is removed for maintenance etc.
∗: When ordering a valve individually, the
E: F: base gasket is not included.
Push-turn Slide locking Since the base gasket is attached to the
locking (manual) manifold, please order the base gasket
(manual) separately if it is needed for maintenance
service.
∗: Select “—” or “K” for the optional individual
SUP/EXH spacer assembly, interface
regulator or double check spacer assembly
∗: Refer to page 36 for with the safety slide with residual pressure release valve.
locking manual override.

Protective class
class # (Mark: )
133
Plug-in Connector Connecting Base
Type 10
Side Ported EX250

SY3000/5000/7000 Series
Type 11
Bottom Ported

RoHS
How to Order Manifolds

Refer to pages 180 (SY5000) and


SS5Y 3 10 S Q 05 U C6
181 (SY7000) for the dimensions
of Type 11/Bottom-ported type. q w e r t y u i o
q Series e SI unit t Input block type
3 SY3000 0 Without SI unit PNP sensor NPN sensor
5 SY5000 Q DeviceNet™ (Negative common) input input
7 SY7000 N PROFIBUS DP (Negative common) Without input block —
TA 2 power 8 in/8 out, 31 slave modes M12, 2 inputs A D
w Type TB AS-Interface supply 4 in/4 out, 31 slave modes
systems
(Negative 1 power
M12, 4 inputs B E
10 Side ported TC common) 8 in/8 out, 31 slave modes M8, 4 inputs C F
supply
11 Bottom ported∗1 TD system 4 in/4 out, 31 slave modes ∗ When not selecting an SI unit, the symbol will be “—.”
∗1 The SY5000 manifold base is used for the Y CANopen (Negative common)
bottom-ported SY3000. When ordering, ZE EtherNet/IP™ (Negative common) y Valve stations
refer to the “Plug-in Manifold Mixed ∗ Ensure a match with the common Symbol Stations Note
Mounting Type” (from page 185). specification of the valve to be used. 02 2 stations
∗ Input block cannot be mounted without SI Double wiring∗1

···
r Input block stations

···
unit.
∗ The supply current from the SI unit of 16 16 stations
— None 02 2 stations
AS-Interface applicable 1 power supply Specified layout∗2
1 1 station
···

···
system specification to the input block and (Up to 32 solenoids available)
···

···

valve is limited. 24 24 stations


8 8 stations
∗1 Double wiring: 2-position single, double,
∗ When not selecting an SI unit, the symbol will 3-position, and 4-position valves can be
be “—.” The maximum number of stations is used on all manifold stations.
limited for the AS-Interface applicable SI unit. Use of a 2-position single solenoid will
result in an unused control signal. If this is
not desired, order with a specified layout.
How to Order Manifold Assembly ∗2 Specified layout: Indicate the wiring
specifications on the manifold specification
sheet. (Note that 2-position double,
Example (SS5Y3-10S-) 3-position closed 3-position, and 4-position valves cannot be
2-position double (24 VDC) centre (24 VDC) used where single wiring has been specified.)
SY3200-5U1 (1 set) SY3300-5U1 (1 set) When determining the number of valve
stations, note that the maximum number of
solenoids for the AS-Interface applicable SI
2-position single (24 VDC) Unit specification is as follows.
SY3100-5U1 (3 sets) • 8 in/8 out specification: Max. 8 solenoids
• 4 in/4 out specification: Max. 4 solenoids
∗ This also includes the number of the blanking
ide plate assembly.
Us
∗ For the product without the SI unit (S0), note
s
n
tio

the maximum number of solenoids of the SI


ta
S

unit that will be mounted. If the layout is


23 specified, indicate it on the manifold
1
ide specification sheet.
Ds
Manifold base (5 stations) u P, E port entry, SUP/EXH block assembly
SS5Y3-10SQ1C-05D-C6 Internal pilot,
P, E port entry Internal pilot External pilot
Built-in silencer
SS5Y3-10SQ1C-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.)
U side (2 to 10 stations) U C G
∗SY3100-5U1 ······················ 3 sets (2-position single part no.)
∗SY3200-5U1 ······················ 1 set (2-position double part no.)
D side (2 to 10 stations) D E H
∗SY3300-5U1 ······················ 1 set (3-position closed centre part no.) Both sides (2 to 24 stations) B F J
The asterisk denotes the symbol for the assembly.
∗ 3/5(E) port is plugged for the built-in silencer type.
Prefix it to the part numbers of the valve, etc. ∗ When the built-in silencer type is used, keep the exhaust port from
coming into direct contact with water or other liquids.
• For the valve arrangement, the valve closest to the D side is considered the 1st station.
• Under the manifold part number, state the valves to be mounted in order starting
with the 1st station as shown in the figure above. If the arrangement becomes too
complicated, specify the details on a manifold specification sheet. For details on the EX250 Integrated Type (For Input/Output) Serial
Transmission System, refer to the Web Catalogue and the
∗ When mixing top-ported configurations, select from those listed on page 141. Operation Manual. For the part numbers of the SI units to be
In such cases, use caution as there is also output on the A and B ports on the base side. mounted, refer to page 2 1 5 . Please download the Operation
Specify on the manifold specification sheet if plugs are required for the A and B ports on Manual via the SMC website, https://www.smc.eu
the base side.
134
SY3000/5000/7000 Series

How to Order Manifolds

i A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)


Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 Ø2  — — — — N1 Ø 1/8"  — — — —
C3 Ø 3.2  — — — — N3 Ø 5/32"   —  —

Straight
C4 Ø4   —  — N7 Ø 1/4"     
Straight

C6 Ø6      N9 Ø 5/16" —    
C8 Ø8 —     N11 Ø 3/8" — —  — 
C10 Ø 10 — —  —  CM∗1 Straight port, mixed sizes     
C12 Ø 12 — —  —  LN3 Ø 5/32"  — — — —

Upward
CM∗1 Straight port, mixed sizes      LN7 Ø 1/4"   — — —
L4 Ø4   — — — LN9 Ø 5/16" —  — — —
L6 Ø6    — — LN11 Ø 3/8" — —  — —
Upward

Elbow∗2
L8 Ø8 —   — — BN3 Ø 5/32"  — — — —

Downward
L10 Ø 10 — —  — — BN7 Ø 1/4"   — — —
L12 Ø 12 — —  — — BN9 Ø 5/16" —  — — —
Elbow∗2

B4 Ø4   — — — BN11 Ø 3/8" — —  — —
Downward

B6 Ø6    — — Elbow port, mixed sizes


LM∗1 (Including upward and    — —
B8 Ø8 —   — — downward piping)

B10 Ø 10 — —  — — P, E port size Ø


Ø 3/8" Ø 1/2" Ø 3/8" Ø 1/2"
B12 Ø 12 — —  — — (One-touch fittings) 5/16"
Elbow port, mixed sizes
LM∗1 (Including upward and    — —
downward piping)

P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).

o Mounting and Option


Option DIN Rail Option
Symbol Mounting
Name plate Station number — Standard length
— — — 0 Without DIN rail (with bracket)
Direct 3 For 3 stations Specify a longer
AA mounting  
rail than the total
···

···

BA  — length of specified
D — — 24 For 24 stations stations.
DIN rail
A mounting  
B  —
∗ Enter the number of stations inside  when it is larger than the number
of valve stations. (Refer to “DIN Rail Option” above.)
∗ Only direct mounting is available for the type 11 bottom-ported type.
∗ Refer to page 319 for the fixation of DIN rail mounting type manifold.
∗ If the DIN rail must be mounted without an SI unit, select D0. Then,
refer to L3 of the dimensions for the DIN rail length and order
separately. (Refer to page 227 for the DIN rail part number.)

Protective class
class # (Mark: )

135
Plug-in Connector Connecting Base SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

q Series y Pilot valve option !0 Manual override


3 SY3000 — Standard (0.7 MPa) —: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K∗1 High pressure type (1.0 MPa) push type locking
∗1 Only the metal seal type is available for the slotted
high pressure type. type

w Type of actuation
1
2-position
Single u Coil type E: F:
2 Double — Standard Push-turn Slide locking
3 Closed centre T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit lever
5 Pressure centre type if the valve is to be continuously type
A∗1 N.C./N.C. energised for long periods of time.
B∗1
4-position
N.O./N.O. ∗ Be careful of the energising time when the
dual 3-port power saving circuit is selected. Refer to
C∗1 N.C./N.O.
page 316 for details. ∗ Refer to page 36 for the safety slide locking
∗1 Only the rubber seal type is available for the manual override.
4-position dual 3-port valve.
i Rated voltage
5 24 VDC
!1 Type of mounting screw
e Seal type — Round head combination screw
0 Rubber seal B Hexagon socket head cap screw
1 Metal seal o Light/surge voltage suppressor K Round head combination screw (Drop prevention type)
and common specification H Hexagon socket head cap screw (Drop prevention type)
Surge voltage Common ∗ For “K” and “H,” the valve body cover has a
Symbol With light
r Pilot type R —
suppressor specification drop prevention construction to stop the
mounting screws from falling out when the
— Internal pilot Non-polar valve is removed for maintenance, etc.
U 
R External pilot ∗ When ordering a valve individually, the
S — Positive base gasket is not included.

Z  common Since the base gasket is attached to the
NS — Negative manifold, please order the base gasket
t Back pressure check valve NZ  common separately if it is needed for maintenance.
Refer to page 222 for base gasket and
(Built-in valve type) ∗ “R" and “U” are applicable for every SI unit.
mounting screw part numbers.
However, “S” and “Z” can be used only for
— None ∗ “B” and “H” cannot be selected for the
CC-Link applicable unit and “NS” and “NZ”
H Built-in
are for units which are not CC-Link
individual SUP/EXH spacer assembly,
∗ Only the rubber seal type is available. A interface regulator, or double check spacer
applicable.
assembly with residual pressure release
manifold installed type is available if a back ∗ For the non-polar type, be careful of surge
pressure check valve with a metal seal is valve.
voltage intrusion.
required. Refer to page 236 for ordering Refer to page 317 for details.
examples. However, it is not recommended ∗ Only “Z” and “NZ” types are available with a
to use the built-in valve type and the manifold power saving circuit.
installed type at the same time because it will
reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.

Protective class
class # (Mark: )
136
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY3000 Series Connector Connecting Base EX250

C2
U
SS5Y3-10S- Stations D - C3, N1
C4, N3 (D)
B C6, N7
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 2
One-touch fitting : Ø 3.2, Ø 1/8"
[1(P), 3/5(E) port] (Station 1)---(Station n)
: Ø 4, Ø 5/32"
Applicable tube O.D.: Ø 8, Ø 5/16" : Ø 6, Ø 1/4"

1 P 1 P
0
BUS

13.6
10.6

63.1
1

56.6
60

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

2
PWR

21.6
4 A4 A4 A4 A4 A
3
18

13.2

(For DIN rail


mounting)
7.5
M3 (Pitch)

11.8
18.3 15.5 P = 10.5 (17.8)
4 x M8 2 x M12
3-pin socket

D side U side

(L5) L1 Manual override∗1

DIN rail holding screw 18 21 63 (Push-turn locking slotted type:


Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
Light/surge voltage suppressor
: Grey (For metal seal)
DIN rail holding screw
DIN rail 2(B) port side : Yellow
(For DIN rail mounting)

8
B A B A B A B A B A
5.5

92.6
14 A 14 A 14 A 14 A 14 A
35

83
0

1
66

60.5

2
40.9

3
4.6

12 B 12 B 12 B 12 B 12 B
4.6
2.7

1.7
) C6: 3.6
N7: 7.4

SI unit
(4.9)
7.5

2 x M4 mounting hole Input block 4 x M4 mounting hole


(

(Fitting for the type with P/E


5.5 L6 L2 1.5 ports on the U and/or D sides)
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3

L1 = 10.5 x n1 + 135.5 + 21 x n2 ∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
L2 = 10.5 x n1 + 42 ∗ These figures show the “SS5Y3-10SQ1A-05D-C6.”
L4 = L3 – 10.5 ∗ Refer to page 182 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 21 x n2 + 82
n1: Valve stations
n2: Input block stations
L3: DIN Rail Overall Length
Valve
stations
(n1) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Input
block
stations (n2)
0 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423
1 210.5 223 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5
2 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5
3 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5
4 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498
5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523
6 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548
7 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548 548 560.5
8 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548 548 560.5 573 585.5
137
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY5000 Series Connector Connecting Base EX250

U C4, N3
SS5Y5-10S- Stations D - C6, N7 (D)
B C8, N9 One-touch fitting
[4(A), 2(B) port]
(Station 1)----------- (Station n) Applicable tube O.D.: Ø 4, Ø 5/32"
One-touch fitting : Ø 6, Ø 1/4"
[1(P), 3/5(E) port] : Ø 8, Ø 5/16"
Applicable tube O.D.: Ø 10, Ø 3/8"

0
BUS 1 P 1 P

73.2
1 2 B2 B2 B2 B2 B

56.6
60

12.4

13.2

2
33.4

3/5 E 3/5 E

29.1
PWR
3
4 A4 A4 A4 A4 A

14.1
8.7
(For DIN rail
mounting)

7.5

M3 (Pitch)
11.8

20 18 P = 16 (20.5)
4 x M8 2 x M12
3-pin socket

D side U side
(L5) L1
Manual override∗1
18 21 63
DIN rail holding screw
(For DIN rail mounting)
( Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
DIN rail holding screw Light/surge voltage suppressor : Grey (For metal seal)
(For DIN rail mounting) 2(B) port side : Yellow
Input block
DIN rail SI unit
8
BA BA BA BA BA
5.5

14 A 14 A 14 A 14 A 14 A
35

97.5

113.4
1
66

2
81.2

3
61.7
5.5

12 B 12 B 12 B 12 B 12 B
23.5

10.9
4.7
(5.9)

2 x M4 mounting hole
(8.3)

4 x M5 mounting hole
5.5 L6 L2 1.5 (Fitting for the type with P/E
ports on the U and/or D sides)
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3

L1 = 16 x n1 + 141.5 + 21 x n2 ∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
L2 = 16 x n1 + 48 ∗ These figures show the “SS5Y5-10SQ1A-05D-C8.”
L4 = L3 – 10.5 ∗ Refer to page 183 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 21 x n2 + 81.5
n1: Valve stations
n2: Input block stations
L3: DIN Rail Overall Length
Valve
stations
(n1) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Input
block
stations (n2)
0 198 223 235.5 248 273 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 560.5
1 223 235.5 260.5 273 285.5 298 323 335.5 348 373 385.5 398 410.5 435.5 448 460.5 485.5 498 510.5 523 548 560.5 573
2 248 260.5 273 298 310.5 323 335.5 360.5 373 385.5 410.5 423 435.5 448 473 485.5 498 523 535.5 548 560.5 585.5 598
3 260.5 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 623
4 285.5 298 323 335.5 348 373 385.5 398 410.5 435.5 448 460.5 473 498 510.5 523 548 560.5 573 585.5 610.5 623 635.5
5 310.5 323 335.5 360.5 373 385.5 398 423 435.5 448 473 485.5 498 510.5 535.5 548 560.5 585.5 598 610.5 623 648 660.5
6 323 348 360.5 373 398 410.5 423 435.5 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 623 635.5 648 660.5 685.5
7 348 360.5 385.5 398 410.5 435.5 448 460.5 473 498 510.5 523 548 560.5 573 585.5 610.5 623 635.5 648 673 685.5 698
8 373 385.5 398 423 435.5 448 473 485.5 498 510.5 535.5 548 560.5 573 598 610.5 623 648 660.5 673 685.5 710.5 723
138
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY7000 Series Connector Connecting Base EX250

C6, N7
U
SS5Y7-10S- Stations D - C8, N9
C10, N11 (D)
B C12 One-touch fitting
[4(A), 2(B) port ]
(Station 1) (Station n) Applicable tube O.D.: Ø 6, Ø 1/4"
One-touch fitting : Ø 8, Ø 5/16"
[1(P), 3/5(E) port] : Ø 10, Ø 3/8"
Applicable tube O.D.: Ø 12, Ø 1/2" : Ø 12

2
82.7
0 1 P 1 P
BUS 2 B2 B2 B2 B2 B
1

56.6
60

13.2
14.2

11.1
2 3/5 E 3/5 E
35.2

8.7

31.6
PWR 4 A4 A4 A4 A4 A
3
(For DIN rail

(10)

M3 (Pitch)
mounting)

25 20.5 P = 19 (21.7)
2 x M12
(14.3)

4 x M8
3-pin socket

D side U side
(L5) L1 Manual override∗1

18 21 63 DIN rail holding screw


(For DIN rail mounting)
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor) : Grey (For metal seal)
DIN rail holding screw Input 2(B) port side : Yellow
(For DIN rail mounting) connector
SI unit
(8) (DIN rail)

B A B A B A B A B A
(35)
14 A 14 A 14 A 14 A 14 A
0

1
66

128.8
115
2

3
(5.5)

96.7
(77.1)

12 B 12 B 12 B 12 B 12 B
5.5
38.9

2 x M4
8.8
3.9
(6)

mounting hole
(9.3)

4 x M5 mounting hole
(17.9)

(A, B port: Ø 12)


(Fitting for the type with P/E
5.5 L6 L2 1.5 ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

L1 = 19 x n1 + 149.7 + 21 x n2 ∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
L2 = 19 x n1 + 56 ∗ These figures show the “SS5Y7-10SQ1A-05D-C10.”
L4 = L3 – 10.5 ∗ Refer to page 184 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 21 x n2 + 81.7
n1: Valve stations
n2: Input block stations

L3: DIN Rail Overall Length


Valve
stations
(n1) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
I/O Unit
stations (n2)
0 223 235.5 260.5 273 298 310.5 335.5 348 373 385.5 410.5 423 448 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5
1 235.5 260.5 273 298 310.5 335.5 348 373 385.5 410.5 423 448 460.5 485.5 498 523 548 560.5 585.5 598 623 635.5 660.5
2 260.5 273 298 310.5 335.5 348 373 398 410.5 435.5 448 473 485.5 510.5 523 548 560.5 585.5 598 623 635.5 660.5 673
3 285.5 298 323 335.5 360.5 373 398 410.5 435.5 448 473 485.5 510.5 523 548 560.5 585.5 598 623 635.5 660.5 673 698
4 298 323 335.5 360.5 373 398 410.5 435.5 448 473 485.5 510.5 523 548 573 585.5 610.5 623 648 660.5 685.5 698 723
5 323 335.5 360.5 373 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5 610.5 623 648 660.5 685.5 698 723 735.5
6 348 360.5 385.5 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5 610.5 623 648 660.5 685.5 698 723 748 760.5
7 360.5 385.5 398 423 435.5 460.5 473 498 510.5 535.5 548 573 598 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5
8 385.5 398 423 448 460.5 485.5 498 523 535.5 560.5 573 598 610.5 635.5 648 673 685.5 710.5 723 748 760.5 785.5 798
139
Plug-in Connector Connecting Base
EX250

SY3000/5000/7000 Series
Type 12 ®

Top Ported
RoHS
How to Order Manifolds

Refer to pages 182 to 184


SS5Y 3 12S Q 05 U
for the dimensions of
Type 12/Top-ported type. q w e r t y u i
q Series w SI unit t Valve stations
3 SY3000 0 Without SI unit Symbol Stations Note
5 SY5000 Q DeviceNet™ (Negative common) 02 2 stations
Double wiring∗1

···
N

···
7 SY7000 PROFIBUS DP (Negative common)
TA 2 power 8 in/8 out, 31 slave modes 16 16 stations
TB AS-Interface supply 4 in/4 out, 31 slave modes
systems 02 2 stations
(Negative 1 power Specified layout∗2
e Input block stations

···
TC 8 in/8 out, 31 slave modes

···
common) supply (Up to 32 solenoids available)
— None TD system 4 in/4 out, 31 slave modes 24 24 stations
1 1 station Y CANopen (Negative common) ∗1 Double wiring: 2-position single, double,
ZE EtherNet/IP™ (Negative common) 3-position, and 4-position valves can be used
···

···

on all manifold stations.


8 8 stations ∗ Ensure a match with the common specification Use of a 2-position single solenoid will result in
of the valve to be used. an unused control signal. If this is not desired,
∗ When not selecting an SI unit, the symbol will be ∗ Input block cannot be mounted without SI unit.
“—.” The maximum number of stations is limited order with a specified layout.
∗ The supply current from the SI unit of AS- ∗2 Specified layout: Indicate the wiring
for the AS-Interface applicable SI unit. Interface applicable 1 power supply system specifications on the manifold specification
specification to the input block and valve is sheet. (Note that 2-position double, 3-position,
limited. and 4-position valves cannot be used where
r Input block type single wiring has been specified.)
When determining the number of valve
PNP sensor NPN sensor stations, note that the maximum number of
input input solenoids for the AS-Interface applicable SI unit
Without input block — specification is as follows.
• 8 in/8 out specification: Max. 8 solenoids
M12, 2 inputs A D • 4 in/4 out specification: Max. 4 solenoids
M12, 4 inputs B E ∗ This also includes the number of the blanking
M8, 4 inputs C F plate assembly.
∗ For the product without the SI unit (S0), note the
∗ When not selecting an SI unit, the symbol will be “—.” maximum number of solenoids of the SI unit that
will be mounted. If the layout is specified,
indicate it on the manifold specification sheet.

How to Order Manifold Assembly y P, E port entry, SUP/EXH block assembly


Internal pilot,
P, E port entry Internal pilot External pilot
Built-in silencer
Example (SS5Y3-12S-) U side (2 to 10 stations) U C∗1 G
3-position closed D side (2 to 10 stations) D E∗1 H
centre (24 VDC)
2-position double (24 VDC) Both sides (2 to 24 stations) B — J
SY3330-5U1-C6 (1 set)
SY3230-5U1-C6 (1 set) ∗1 For SUP/EXH block assembly specifications, built-in silencer types will have
2-position single (24 VDC) P port entry stipulated.
∗ The P and E ports are only available on the U and D sides for the built-in silencer type. 3/5(E) port is
SY3130-5U1-C6 (3 sets)
plugged. The silencer exhaust port is located on the opposite side of the P and E port entry.
(Example: When the P and E port entry is on the D side, the silencer exhaust port is on the U side.)
∗ When the built-in silencer type is used, keep the exhaust port from coming
into direct contact with water or other liquids.
ide
Us u P, E port size (One-touch fittings)
s
n
tio

SY3000 SY5000 SY7000


ta

Symbol
S

2 3 — Ø8 Ø 10 Ø 12
e
1
D sid
N Ø 5/16" Ø 3/8" Ø 1/2"
Manifold base (5 stations) ∗ For N, sizes are in inches.
SS5Y3-12SQ1C-05D
i Mounting ∗ If the DIN rail must be mounted
SS5Y3-12SQ1C-05D ··· 1 set (Type 12 5-station manifold base part no.)
— Direct mounting without an SI unit, select D0. Then,
∗SY3130-5U1-C6 ··········· 3 sets (2-position single part no.) D DIN rail mounting (With DIN rail) refer to L3 of the dimensions for the
D0 DIN rail mounting (Without DIN rail) DIN rail length and order separately.
∗SY3230-5U1-C6 ··········· 1 set (2-position double part no.) (Refer to page 227 for the DIN rail
∗SY3330-5U1-C6 ··········· 1 set (3-position closed centre part no.) D3 For 3 stations Specify a length
part number.)
···

···

The asterisk denotes the symbol for the assembly. longer than that of ∗ Refer to page 319 for the fixation of
Prefix it to the part numbers of the valve, etc. D24 For 24 stations the standard rail. DIN rail mounting type manifold.

• For the valve arrangement, the valve closest to the D side is considered the 1st station. For details on the EX250 Integrated Type (For Input/Output) Serial
• Under the manifold part number, state the valves to be mounted in order starting Transmission System, refer to the Web Catalogue and the Operation
with the 1st station as shown in the figure above. If the arrangement becomes too Manual. For the part numbers of the SI units to be mounted, refer to page
complicated, specify the details on a manifold specification sheet. 215. Please download the Operation Manual via the SMC website, https://
www.smc.eu

140
SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported

q Series y Pilot valve option !1 A, B port size


3 SY3000 — Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K∗1 High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗1 Only the metal seal type is available for the 01 1/8 SY5000
high pressure type. 02 1/4 SY7000
w Type of actuation One-touch fitting (Metric)

u Coil type A, B port SY3000 SY5000 SY7000


1 Single Symbol
2-position 
2 Double C2 Ø2 — —
— Standard C3 Ø 3.2  — —
3 Closed centre
T With power saving circuit (Continuous duty type)
C4 Ø4   —
4 3-position Exhaust centre
∗ Be sure to select the power saving circuit C6 Ø6   
5 Pressure centre
type if the valve is to be continuously  
A∗1 N.C./N.C. C8 Ø8 —
4-position energised for long periods of time.
B∗1 N.O./N.O. ∗ Be careful of the energising time when the C10 Ø 10 — — 
dual 3-port
C∗1 N.C./N.O. power saving circuit is selected. Refer to C12 Ø 12 — — 
∗1 Only the rubber seal type is available for the page 316 for details. One-touch fitting (Inch)
4-position dual 3-port valve. Symbol A, B port SY3000 SY5000 SY7000
N1 Ø 1/8"  — —
i Rated voltage N3 Ø 5/32"   —
e Seal type 5 24 VDC N7
N9
Ø 1/4"
Ø 5/16"






0 Rubber seal
N11 Ø 3/8" — — 
1 Metal seal
o Light/surge voltage suppressor
and common specification
r Pilot type Symbol With light
Surge voltage Common !2 Thread type
suppressor specification
— Rc
— Internal pilot R —
Non-polar F G
R External pilot U  N NPT
S — Positive T NPTF

Z  common
∗ Only — is available for M5.
t Back pressure check valve NS
NZ


Negative
common
(Built-in valve type)
∗ “R" and “U” are applicable for every SI unit.

H
None
Built-in
∗ For the non-polar type, be careful of surge !3 Type of mounting screw
voltage intrusion.
∗ Only the rubber seal type is available. A
— Round head combination screw
Refer to page 317 for details.
manifold installed type is available if a back ∗ Only “Z” and “NZ” types are available with a B Hexagon socket head cap screw
pressure check valve with a metal seal is power saving circuit. K Round head combination screw (Drop prevention type)
required. Refer to page 236 for ordering H Hexagon socket head cap screw (Drop prevention type)
examples. However, it is not recommended ∗ For “K” and “H,” the valve body cover has a
to use the built-in valve type and the manifold
installed type at the same time because it will !0 Manual override drop prevention construction to stop the
mounting screws from falling out when the
reduce the flow. —: D: valve is removed for maintenance, etc.
∗ The built-in valve type back pressure check Non-locking Push-turn ∗ When ordering a valve individually, the
valve is not available for the 3-position type push type locking slotted base gasket is not included.
or the SY7000. type Since the base gasket is attached to the
manifold, please order the base gasket
separately if it is needed for maintenance.
Refer to page 222 for base gasket and
mounting screw part numbers.
∗ "B" and "H" cannot be selected for the
E: F: individual SUP/EXH spacer assembly or
Push-turn Slide locking interface regulator.
locking lever type
type

∗ Refer to page 36 for the safety slide locking


manual override.

Protective class
class # (Mark: )
141
Plug-in Connector Connecting Base
Type 10
Side Ported EX260

SY3000/5000/7000 Series
Type 11
Bottom Ported

®
Refer to page 1 4 5 for details on manifolds that
support safety communication (PROFIsafe).
RoHS
How to Order Manifolds

Refer to pages 180 (SY5000) and SS5Y 3 10 S NAN 05 U C6


181 (SY7000) for the dimensions
of Type 11/Bottom-ported type.
q w e r t y u i
q Series r Valve stations t P, E port entry
3 SY3000 In the case of the 32-output SI unit U U side (2 to 10 stations)
5 SY5000 Symbol Stations Note D D side (2 to 10 stations)
7 SY7000 02 2 stations B Both sides (2 to 24 stations)
Double wiring∗1

w Type 16 16 stations
02 2 stations y SUP/EXH block assembly
10 Side ported Specified layout∗2 — Internal pilot

11 Bottom ported∗1 (Up to 32 solenoids available)


24 24 stations S Internal pilot, Built-in silencer
∗1 The SY5000 manifold base is used for the R External pilot
bottom-ported SY3000. When ordering, In the case of the 16-output SI unit
refer to the “Plug-in Mixed Type Manifold” Symbol Stations Note ∗ 3/5(E) port is plugged for the built-in silencer
(from page 185). type.
02 2 stations ∗ When the built-in silencer type is used, keep
Double wiring∗1

the exhaust port from coming into direct


e SI unit specifications 08 8 stations
02 2 stations
contact with water or other liquids.
(Output polarity, Protocol, Number of outputs, Communication connector) Specified layout∗2

Symbol (Output polarity) Number


Communication 16 16 stations
(Up to 16 solenoids available) Refer to the page on the right for u.
Positive common Negative common Protocol of
outputs
connector ∗1 Double wiring: 2-position single, double,
(NPN) (PNP)
3-position, and 4-position valves can be
0∗1 Without SI unit used on all manifold stations. i Mounting and Option
QA QAN 32 Use of a 2-position single solenoid will Option
DeviceNet™ M12 Symbol Mounting
QB QBN 16 result in an unused control signal. If this is Name plate Station number
NA NAN 32 not desired, order with a specified layout
M12 ∗2 Specified layout: Indicate the wiring
— — —
NB NBN PROFIBUS 16 Direct
specifications on the manifold specification AA  
NC NCN DP 32 ∗4 mounting
D-sub sheet. BA  —
ND NDN 16 (Note that 2-position double, 3-position, and D — —
VA VAN 32 DIN rail
CC-Link M12
4-position valves cannot be used where A  
VB VBN 16 single wiring has been specified.) mounting
B  —
DA DAN 32 ∗ This also includes the number of the blanking
EtherCAT M12 plate assembly. ∗ Enter the number of stations inside  when it
DB DBN 16 is larger than the number of valve stations.
∗ For the model without the SI unit (S0), note
FA FAN 32
the maximum number of solenoids of the SI (Refer to “DIN Rail Option” below.)
PROFINET M12
FB FBN 16 unit that will be mounted. If the layout is ∗ Only direct mounting is available for the type
EA EAN 32 specified, indicate it on the manifold 11 bottom-ported type.
EtherNet/IP™ M12
specification sheet. ∗ Refer to page 319 for the fixation of DIN rail
EB EBN 16
mounting type manifold.
—∗3 GAN Ethernet 32
M12
—∗3 GBN POWERLINK 16 DIN Rail Option
—∗3 KAN IO-Link 32 ∗ 5 M12 — Standard length
∗1 Without SI unit, the output polarity is 0 Without DIN rail (with bracket)
decided by the SI unit used. 3 For 3 stations
Ensure a match with the common Specify a longer rail than the

specification of the valves to be used. total length of specified stations.


24 For 24 stations
∗2 DIN rail cannot be mounted without SI unit.
∗3 Positive common (NPN) type is not ∗ If the DIN rail must be mounted without an SI
applicable. unit, select D0. Then, refer to L3 of the
∗4 IP40 for the D-sub applicable dimensions for the DIN rail length and order
communication connector specification separately. (Refer to page 227 for the DIN
∗5 Only the 32 outputs type is available. rail part number.)

For details on the EX260 Integrated Type (For Output) Serial


Transmission System, refer to the Web Catalogue and the
Operation Manual. For the part numbers of the SI units to be
mounted, refer to page 2 1 6 . Please download the Operation
Manual via the SMC website, https://www.smc.eu

142
SY3000/5000/7000 Series

How to Order Manifolds

u A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)


Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 Ø2  — — — — N1 Ø 1/8"  — — — —
C3 Ø 3.2  — — — — N3 Ø 5/32"   —  —

Straight
C4 Ø4   —  — N7 Ø 1/4"     
Straight

C6 Ø6      N9 Ø 5/16" —    
C8 Ø8 —     N11 Ø 3/8" — —  — 
C10 Ø 10 — —  —  CM∗1 Straight port, mixed sizes     
C12 Ø 12 — —  —  LN3 Ø 5/32"  — — — —

Upward
CM∗1 Straight port, mixed sizes      LN7 Ø 1/4"   — — —
L4 Ø4   — — — LN9 Ø 5/16" —  — — —
L6 Ø6    — — LN11 Ø 3/8" — —  — —
Upward

Elbow∗2
L8 Ø8 —   — — BN3 Ø 5/32"  — — — —

Downward
L10 Ø 10 — —  — — BN7 Ø 1/4"   — — —
L12 Ø 12 — —  — — BN9 Ø 5/16" —  — — —
Elbow∗2

B4 Ø4   — — — BN11 Ø 3/8" — —  — —
Downward

B6 Ø6    — — Elbow port, mixed sizes


LM∗1 (Including upward and    — —
B8 Ø8 —   — — downward piping)

B10 Ø 10 — —  — — P, E port size Ø


Ø 3/8" Ø 1/2" Ø 3/8" Ø 1/2"
B12 Ø 12 — —  — — (One-touch fittings) 5/16"
Elbow port, mixed sizes
LM∗1 (Including upward and    — —
downward piping)

P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).

How to Order Manifold Assembly

Example (SS5Y3-10SNAN-)
SS5Y3-10SNAN-04D-C6···1 set (Type 10 4-station manifold base part no.)
2-position single (24 VDC) 2-position double (24 VDC) ∗SY3100-5U1·····················2 sets (2-position single part no.)
SY3100-5U1 (2 sets) SY3200-5U1 (1 set) ∗SY3200-5U1·····················1 set (2-position double part no.)
3-position closed centre (24 VDC) ∗SY3300-5U1·····················1 set (3-position closed centre part no.)
SY3300-5U1 (1 set)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.

• For the valve arrangement, the valve closest to the D side is


considered the 1st station.
• Under the manifold part number, state the valves to be mounted in
ide order starting with the 1st station as shown in the figure above. If the
Us arrangement becomes too complicated, specify the details on a
s
n

manifold specification sheet.


tio
ta
S

3
2 ∗ When mixing top-ported configurations, select from those listed on
1
e page 152. Specify on the manifold specification sheet if plugs are
Manifold base (4 stations) sid
D required for the A and B ports on the manifold.
SS5Y3-10SNAN-04D-C6

Protective class
class # (Mark: )

143
Plug-in Connector Connecting Base SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

q Series y Pilot valve option !0 Manual override


3 SY3000 — Standard (0.7 MPa) —: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K∗1 High pressure type (1.0 MPa) push type locking slotted
∗1 Only the metal seal type is available for the type
high pressure type.

w Type of actuation
1
2-position
Single u Coil type
2 Double — Standard E: F:
3 Closed centre T With power saving circuit (Continuous duty type) Push-turn Slide locking
4 3-position Exhaust centre locking lever type
∗ Be sure to select the power saving circuit
5 Pressure centre type
type if the valve is to be continuously
A∗1 N.C./N.C. energised for long periods of time.
4-position ∗ Be careful of the energising time when the
B∗1 dual 3-port
N.O./N.O.
C∗1 N.C./N.O. power saving circuit is selected. Refer to
page 316 for details.
∗1 Only the rubber seal type is available for the
∗ Refer to page 36 for the safety slide locking
4-position dual 3-port valve.
i Rated voltage manual override.

5 24 VDC

e Seal type !1 Type of mounting screw


0 Rubber seal
1 Metal seal o Light/surge voltage suppressor —
B
Round head combination screw
Hexagon socket head cap screw
and common specification
Round head combination screw
Surge voltage Common K (Drop prevention type)
Symbol With light
suppressor specification
r Pilot type R — H
Hexagon socket head cap screw
(Drop prevention type)
— Internal pilot Non-polar
U  ∗ For “K” and “H,” the valve body cover has a
R External pilot S — Positive
 drop prevention construction to stop the
Z  common mounting screws from falling out when the
NS — Negative valve is removed for maintenance, etc.
∗ When ordering a valve individually, the
t Back pressure check valve NZ  common
base gasket is not included.
(Built-in valve type) ∗ Select “R,” “U,” “S,” or “Z” for the valve when
Since the base gasket is attached to the
the SI unit output polarity is — (positive
— None manifold, please order the base gasket
common). Select “R,” “U,” “NS,” or “NZ” for
H Built-in separately if it is needed for maintenance.
the valve when the SI unit output polarity is N
Refer to page 222 for base gasket and
∗ Only the rubber seal type is available. A (negative common).
mounting screw part numbers.
manifold installed type is available if a back ∗ For the non-polar type, be careful of surge
∗ “B” and “H” cannot be selected for the
pressure check valve with a metal seal is voltage intrusion.
individual SUP/EXH spacer assembly,
required. Refer to page 236 for ordering Refer to page 317 for details.
interface regulator, or double check spacer
examples. However, it is not recommended ∗ Only “Z” and “NZ” types are available with a
assembly with residual pressure release
to use the built-in valve type and the manifold power saving circuit.
valve.
installed type at the same time because it will
reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.

Protective class
class # (Mark: )
144
Plug-in Connector Connecting Base
Type 10
Side Ported EX260 Safety Communication Protocol (PROFIsafe)

SY3000/5000/7000 Series
Type 11
Bottom Ported

®
Using the safety communication protocol
Refer to the EX260 Web Catalogue for details on units that support the safety communication protocol. RoHS
When using a manifold valve within an ISO 1 3 8 4 9 -compliant safety system, the device needs to be
considered from both the pneumatic circuit and the electric side.
Devices (including valves) need to be selected based on whether their functions are in line with the
safety level of the equipment as a whole.
The use of valves that have been validated as being compliant with ISO 13849-2 may be required.
For details on valves that have been validated, please contact SMC.
In addition, refer to “Safety Instructions” for precautions on model selection.
Refer to for details on manifolds that support
Fieldbus and Industrial Ethernet.
How to Order Manifolds

Refer to pages 180 (SY5000) and SS5Y 3 10 S FPN 05 U C6


181 (SY7000) for the dimensions
of Type 11/Bottom-ported type.
q w e r t y u i
q Series r Valve stations y SUP/EXH block assembly
3 SY3000 Symbol Stations Note — Internal pilot
5 SY5000 02 2 stations S Internal pilot, Built-in silencer
7 SY7000 Double wiring∗1

R External pilot
16 16 stations ∗ 3/5(E) port is plugged for the built-in silencer
w Type 02 2 stations
Specified layout∗2
type.
∗ When the built-in silencer type is used, keep

10 Side ported (Up to 32 solenoids available) the exhaust port from coming into direct
24 24 stations
11 Bottom ported∗1 contact with water or other liquids.
∗1 The SY5000 manifold base is used for the ∗1 Double wiring: 2-position single, double,
bottom-ported SY3000. When ordering, 3-position, and 4-position valves can be
refer to the “Plug-in Mixed Type Manifold” used on all manifold stations.
Use of a 2-position single solenoid will
Refer to the page on the right for u.
(from page 185).
result in an unused control signal. If this is

i Mounting and Option


not desired, order with a specified layout
∗2 Specified layout: Indicate the wiring
e SI unit specifications specifications on the manifold specification Option
(Output polarity, Protocol, Number of outputs, Communication connector) sheet. Symbol Mounting
Name plate Station number
Symbol (Output polarity) (Note that 2-position double, 3-position, and — — —
Number
Communication 4-position valves cannot be used where Direct
Positive common Negative common Protocol of
connector AA  
outputs single wiring has been specified.) mounting
(NPN) (PNP)
∗ This also includes the number of the blanking BA  —
0∗1 Without SI unit plate assembly. D — —
—∗3 FPN PROFIsafe 32∗4 M12 A
DIN rail
 
mounting
∗1 Without SI unit, the output polarity is t P, E port entry B  —
decided by the SI unit used. U U side (2 to 10 stations) ∗ Enter the number of stations inside  when it
Ensure a match with the common is larger than the number of valve stations.
specification of the valves to be used. D D side (2 to 10 stations)
(Refer to “DIN Rail Option” below.)
∗2 DIN rail cannot be mounted without SI unit. B Both sides (2 to 24 stations)
∗ Only direct mounting is available for the type
∗3 Positive common (NPN) type is not 11 bottom-ported type.
applicable. ∗ Refer to page 319 for the fixation of DIN rail
∗4 Only the 32 outputs type is available. mounting type manifold.

DIN Rail Option


— Standard length
0 Without DIN rail (with bracket)
3 For 3 stations
Specify a longer rail than the

total length of specified stations.


24 For 24 stations
∗ If the DIN rail must be mounted without an SI
unit, select D0. Then, refer to L3 of the
dimensions for the DIN rail length and order
separately. (Refer to page 227 for the DIN
rail part number.)

For details on the EX260 Integrated Type (For Output) Serial Transmission System, refer to the Web Catalogue and the Operation Manual. For the part
numbers of the SI units to be mounted, refer to page 216. Please download the Operation Manual via the SMC website, https://www.smc.eu

145
Plug-in Connector Connecting Base SY3000/5000/7000 Series

u A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)


Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 Ø2  — — — — N1 Ø 1/8"  — — — —
C3 Ø 3.2  — — — — N3 Ø 5/32"   —  —

Straight
C4 Ø4   —  — N7 Ø 1/4"     
Straight

C6 Ø6      N9 Ø 5/16" —    
C8 Ø8 —     N11 Ø 3/8" — —  — 
C10 Ø 10 — —  —  CM∗1 Straight port, mixed sizes     
C12 Ø 12 — —  —  LN3 Ø 5/32"  — — — —
Upward

CM∗1 Straight port, mixed sizes      LN7 Ø 1/4"   — — —


L4 Ø4   — — — LN9 Ø 5/16" —  — — —
L6 Ø6    — — LN11 Ø 3/8" — —  — —
Upward

Elbow∗2

L8 Ø8 —   — — BN3 Ø 5/32"  — — — —
Downward

L10 Ø 10 — —  — — BN7 Ø 1/4"   — — —


L12 Ø 12 — —  — — BN9 Ø 5/16" —  — — —
Elbow∗2

B4 Ø4   — — — BN11 Ø 3/8" — —  — —
Downward

B6 Ø6    — — Elbow port, mixed sizes


LM∗1 (Including upward and    — —
B8 Ø8 —   — — downward piping)

B10 Ø 10 — —  — — P, E port size Ø


Ø 3/8" Ø 1/2" Ø 3/8" Ø 1/2"
B12 Ø 12 — —  — — (One-touch fittings) 5/16"
Elbow port, mixed sizes
LM∗1 (Including upward and    — —
downward piping)

P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).

Protective class
class # (Mark: )
146
SY3000/5000/7000 Series

[Validated product examples]


Please contact SMC for further details as supported variations are continually being added.

∗ 2 -position double of rubber seal and manual override with locking function
(D, E, F type) are excluded, because they don’t comply with safety standard.

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

q Series y Pilot valve option !0 Manual override


3 SY3000 — Standard (0.7 MPa) —:
5 SY5000 B Quick response type (0.7 MPa) Non-locking
7 SY7000 K∗1 High pressure type (1.0 MPa) push type
∗1 Only the metal seal type is available for the
high pressure type.

w Type of actuation
1
2-position
Single u Coil type
2 Double∗2 — Standard
3 Closed centre T With power saving circuit (Continuous duty type)
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit !1 Type of mounting screw
5 Pressure centre type if the valve is to be continuously — Round head combination screw
A∗1 N.C./N.C. energized for long periods of time.
B Hexagon socket head cap screw
4-position ∗ Be careful of the energizing time when the
B∗1 dual 3-port
N.O./N.O. Round head combination screw
C∗1 N.C./N.O. power saving circuit is selected. Refer to K (Drop prevention type)
page 316 for details.
∗1 Only the rubber seal type is available for the Hexagon socket head cap screw
4-position dual 3-port valve. H (Drop prevention type)
∗2 Except the rubber seal i Rated voltage ∗ For “K” and “H,” the valve body cover has a
5 24 VDC drop prevention construction to stop the
mounting screws from falling out when the
e Seal type valve is removed for maintenance, etc.
∗ When ordering a valve individually, the
0
1
Rubber seal
Metal seal
o Light/surge voltage suppressor base gasket is not included.
and common specification Since the base gasket is attached to the
manifold, please order the base gasket
Surge voltage Common separately if it is needed for maintenance.
Symbol With light
suppressor specification
r Pilot type
Refer to page 222 for base gasket and
— — — mounting screw part numbers.
— Internal pilot R — Non-polar ∗ “B” and “H” cannot be selected for the
R External pilot U  individual SUP/EXH spacer assembly,
 interface regulator, or double check spacer
NS — Negative
assembly with residual pressure release
NZ  common
valve.
t Back pressure check valve ∗ For the non-polar type, be careful of surge
voltage intrusion.
(Built-in valve type) Refer to page 317 for details.
— None ∗ Only “NZ” type is available with a power
H Built-in saving circuit.
∗ Only the rubber seal type is available. A
manifold installed type is available if a back
pressure check valve with a metal seal is
required. Refer to page 236 for ordering
examples. However, it is not recommended
to use the built-in valve type and the manifold
installed type at the same time because it will
reduce the flow.
∗ The back pressure check valve is not available
for the 3-position type or the SY7000.

147
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY3000 Series Connector Connecting Base EX260

C2,
U
SS5Y3-10S- Stations D - C3, N1
C4, N3 (D)
B C6, N7

One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: Ø 2
Applicable tube O.D.: Ø 8, Ø 5/16" : Ø 3.2, Ø 1/8"
(Station 1)----------- (Station n) : Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"

manual override)
BUS OUT
[Communication connector D-sub]

(Slide locking
1 P 1 P
76.7

63.1
68.8
10.6
13.6
BUS IN

56.6
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

PWR

21.6
4 A4 A4 A4 A4 A BUS
18

1 P

76.7
3/5 E 2 B2

46.5 (17.8)

(7.5)
(11.8)
PWR 4 A4

15.5 (Pitch)
P=10.5

46.5
D side U side
Manual override∗1

(
Push-turn locking slotted type:
Press, then rotate it. )
DIN rail holding screw (L5) 4(A) port side : Blue (For rubber seal)
L1
: Grey (For metal seal)
(For DIN rail mounting)
2(B) port side : Yellow
Light/surge voltage
suppressor (8)
DIN rail
(5.5)

B A B A B A B A
(35)

92.6

14 A 14 A 14 A 14 A
83
80.2

60.5
(40.9)
4.6

12 B 12 B 12 B 12 B
22.2

4.6
1.7
(4.9)

SI unit 4 x M4 mounting hole


)
C6:3.6
N7:7.4

(Fitting for the type with P/E


ports on U and/or D sides)
(

L2 1.5
(5.3) L4
(DIN rail mounting hole pitch: 12.5)
(L3)

∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10SQA-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
L1 103.7 114.2 124.7 135.2 145.7 156.2 166.7 177.2 187.7 198.2 208.7 219.2 229.7 240.2 250.7 261.2
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5
L3 135.5 148 148 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 285.5
L4 125 137.5 137.5 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275 275
L5 16 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12

n: Stations 18 19 20 21 22 23 24
L1 271.7 282.2 292.7 303.2 313.7 324.2 334.7
L2 231 241.5 252 262.5 273 283.5 294
L3 298 310.5 323 335.5 348 348 360.5
L4 287.5 300 312.5 325 337.5 337.5 350
L5 13 14 15 16 17 12 13

148
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY5000 Series Connector Connecting Base EX260

U C4, N3
SS5Y5-10S- Stations DB - C6, N7 (D)
C8, N9
One-touch fitting
[4(A), 2(B) port]
One-touch fitting Applicable tube O.D.:: Ø 4, Ø 5/32"
[1(P), 3/5(E) port] : Ø 6, Ø 1/4"
Applicable tube O.D.: Ø 10 (Station 1)----------- (Station n) : Ø 8, Ø 5/16"
: Ø 3/8"

[Communication connector D-sub]

manual override)
(Slide locking
BUS OUT

78.9
76.7

14.1
1 P 1 P

73.2
BUS IN 2 B2 B2 B2 B2 B

56.6
BUS

3/5 3/5
33.4

E E

76.7
1 P

29.1
PWR
2 B2
4 A4 A4 A4 A4 A
3/5 E
PWR
8.7
12.4

4 A4

(11.8)
(Pitch) (20.5)

(7.5)
48.2 18 P=16
48.2

D side U side
Manual override∗1

(
Push-turn locking slotted type:
Press, then rotate it. )
DIN rail holding screw (L5) 4(A) port side : Blue (For rubber seal)
L1
(For DIN rail mounting) : Grey (For metal seal)
2(B) port side : Yellow
Light/surge voltage suppressor
(8)
DIN rail
(5.5)

B A B A B A B A
(35)

14 A 14 A 14 A 14 A
97.5
113.4
101

81.2
(61.7)
5.5

12 B 12 B 12 B 12 B
10.9
1.4

4.7
(5.9)
(8.3)

SI unit
4 x M5 mounting hole

34.2 L2 1.5
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5) (Fitting for the type with P/E
(L3) ports on U and/or D sides)

∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10SQA-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 360.7
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320
L3 148 160.5 185.5 198 210.5 235.5 248 260.5 273 298 310.5 323 348 360.5 373 385.5
L4 137.5 150 175 187.5 200 225 237.5 250 262.5 287.5 300 312.5 337.5 350 362.5 375
L5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14 12.5

n: Stations 18 19 20 21 22 23 24
L1 376.7 392.7 408.7 424.7 440.7 456.7 472.7
L2 336 352 368 384 400 416 432
L3 410.5 423 435.5 448 473 485.5 498
L4 400 412.5 425 437.5 462.5 475 487.5
L5 17 15 13.5 11.5 16 14.5 12.5

149
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY7000 Series Connector Connecting Base EX260

C6, N7
U
SS5Y7-10S- Stations D - C8, N9
C10, N11 (D)
B C12

One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 12, Ø 1/2"
(Station 1) (Station n)
[Communication connector D-sub]

2
BUS OUT
BUS

82.7
1 P 1 P
76.7

1 P

76.7
2 B2 B2 B2 B2 B
BUS IN 2 B2

56.6
11.1
3/5 E 3/5 E
35.2

8.7

31.6
PWR 4 A4 A4 A4 A4 A 3/5 E
PWR 4 A4
14.2

(For DIN rail


mounting)
(10)
(21.7) 53.2

(14.3)
(Pitch)
53.2 20.5 P = 19 One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
: Ø 12
D side U side

(L5) L1
Manual override∗1
DIN rail holding screw
(For DIN rail mounting) Light/surge voltage suppressor
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
2(B) port side: Yellow

(8) (DIN rail)

B A B A B A B A
(35)

14 A 14 A 14 A 14 A 14 A
102.3

128.8
115
(5.5)

96.7
(77.1)

12 B 12 B 12 B 12 B 12 B
5.5
14

8.8
3.9

SI unit
(6)
(9.3)

(A, B port: Ø 12) 4 x M5 mounting hole


(17.9)

34.4 L2 1.5 (Fitting for the type with P/E


(5.3) (L4) ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)

∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10SQA-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 134.9 153.9 172.9 191.9 210.9 229.9 248.9 267.9 286.9 305.9 324.9 343.9 362.9 381.9 400.9 419.9 438.9 457.9 476.9 495.9 514.9 533.9 552.9
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 160.5 185.5 198 223 235.5 260.5 273 298 310.5 335.5 348 373 398 410.5 435.5 448 473 485.5 510.5 523 548 560.5 585.5
L4 150 175 187.5 212.5 225 250 262.5 287.5 300 325 337.5 362.5 387.5 400 425 437.5 462.5 475 500 512.5 537.5 550 575
L5 13 16 12.5 15.5 12.5 15.5 12 15 12 15 11.5 14.5 17.5 14.5 17.5 14 17 14 17 13.5 16.5 13.5 16.5
150
Plug-in Connector Connecting Base
EX260
Type 12
SY3000/5000/7000 Series
®

Top Ported
RoHS
How to Order Manifolds

Refer to pages 182 to 184


for the dimensions of
SS5Y 3 12S NAN 05 U
Type 12/Top-ported type.
q w e r t y u
q Series e Valve stations r P, E port entry
3 SY3000 In the case of the 32-output SI unit U∗1 U side (2 to 10 stations)
5 SY5000 Symbol Stations Note D∗1 D side (2 to 10 stations)
7 SY7000 02 2 stations B Both sides (2 to 24 stations)
Double wiring∗1


∗1 t For type “S”, SUP/EXH block assembly with
w SI unit specifications 16 16 stations a built-in silencer, choose U or D for P, E port
(Output polarity, Protocol, Number of outputs, Communication connector) 02 2 stations entry.
Specified layout∗2

Symbol (Output polarity)


Positive common Negative common Protocol
Number
of
Communication
24 24 stations
(Up to 32 solenoids available) t SUP/EXH block assembly
connector — Internal pilot
(NPN) (PNP) outputs
In the case of the 16-output SI unit
0∗1 Without SI unit S Internal pilot, Built-in silencer
Symbol Stations Note
QA QAN 32 R External pilot
DeviceNet™ M12 02 2 stations ∗ The P and E ports are only available on the U and
QB QBN 16 Double wiring∗1

D sides for the built-in silencer type. 3/5(E) port is


NA NAN 32 08 8 stations plugged. The silencer exhaust port is located on
M12
NB NBN PROFIBUS 16 02 2 stations the opposite side of the P and E port entry.
NC NCN DP 32 ∗4 Specified layout∗2 (Example: When the P and E port entry is on the

D-sub (Up to 16 solenoids available) D side, the silencer exhaust port is on the U side.)
ND NDN 16 16 16 stations ∗ When the built-in silencer type is used, keep the
VA VAN 32 ∗1 Double wiring: 2-position single, double, exhaust port from coming into direct contact with
CC-Link M12
VB VBN 16 3-position, and 4-position valves can be used water or other liquids.
DA DAN 32 on all manifold stations.
DB DBN
EtherCAT
16
M12 Use of a 2-position single solenoid will result in
an unused control signal. If this is not desired,
y P, E port size (One-touch fittings)
FA FAN 32 order with a specified layout. Symbol SY3000 SY5000 SY7000
PROFINET M12
FB FBN 16 ∗2 Specified layout: Indicate the wiring
EA EAN 32 specifications on the manifold specification — Ø8 Ø 10 Ø 12
EtherNet/IP™ M12 sheet.
EB EBN 16 N Ø 5/16" Ø 3/8" Ø 1/2"
(Note that 2-position double, 3-position, and
—∗3 GAN Ethernet 32
M12 4-position valves cannot be used where single ∗ For N, sizes are in inches.
—∗3 GBN POWERLINK 16 wiring has been specified.)
—∗3 KAN IO-Link 32∗5 M12 ∗ This also includes the number of the blanking
plate assembly.
u Mounting
∗1 Without SI unit, the output polarity is decided — Direct mounting
by the SI unit used. ∗ For the model without the SI unit (S0), note the
Ensure a match with the common specification maximum number of solenoids of the SI unit that D DIN rail mounting (With DIN rail)
of the valves to be used. will be mounted. If the layout is specified, D0 DIN rail mounting (Without DIN rail)
∗2 DIN rail cannot be mounted without SI unit. indicate it on the manifold specification sheet.
D3 For 3 stations Specify a length longer
∗3 Positive common (NPN) type is not applicable.

than that of the standard


∗4 IP40 for the D-sub applicable communication
D24 For 24 stations rail.
connector specification
∗5 Only the 32 outputs type is available. ∗ If the DIN rail must be mounted without an SI unit,
select D0. Then, refer to L3 of the dimensions for
For details on the EX 2 6 0 Integrated Type (For Output) Serial Transmission System, refer to the Web the DIN rail length and order separately. (Refer to
Catalogue and the Operation Manual. For the part numbers of the SI units to be mounted, refer to page page 227 for the DIN rail part number.)
216. Please download the Operation Manual via the SMC website, https://www.smc.eu ∗ Refer to page 319 for the fixation of DIN rail
mounting type manifold.

How to Order Manifold Assembly


Example (SS5Y3-12SNAN-)
2-position single (24 VDC) 2-position double (24 VDC)
SS5Y3-12SNAN-04D ····· 1 set (Type 12 4-station manifold base part no.)
SY3230-5U1-C6 (1 set)
SY3130-5U1-C6 (2 sets) ∗SY3130-5U1-C6 ············· 2 sets (2-position single part no.)
3-position closed centre (24 VDC) ∗SY3230-5U1-C6 ············· 1 set (2-position double part no.)
SY3330-5U1-C6 (1 set) ∗SY3330-5U1-C6 ············· 1 set (3-position closed centre part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.

• For the valve arrangement, the valve closest to the D side is


considered the 1st station.
de
si

• Under the manifold part number, state the valves to be mounted in


U
s
n

order starting with the 1st station as shown in the figure above. If the
tio
ta
S

arrangement becomes too complicated, specify the details on a


3

manifold specification sheet.


2
1
de

Manifold base (4 stations)


si
D

SS5Y3-12SNAN-04D

151
Plug-in Connector Connecting Base SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported

q Series u Coil type !1 A, B port size


3 SY3000 — Standard Thread piping
5 SY5000 T With power saving circuit (Continuous duty type) Symbol Port size Applicable series
7 SY7000 ∗ Be sure to select the power saving circuit M5 M5 x 0.8 SY3000
type if the valve is to be continuously 01 1/8 SY5000
energised for long periods of time. 02 1/4 SY7000
w Type of actuation ∗ Be careful of the energising time when the
power saving circuit is selected. Refer to One-touch fitting (Metric)
1 Single page 316 for details.
2-position Symbol A, B port SY3000 SY5000 SY7000
2 Double

C2 Ø2 — —
3
4 3-position
Closed centre
Exhaust centre
i Rated voltage C3 Ø 3.2  — —
5 24 VDC C4 Ø4   —
5 Pressure centre
C6 Ø6   
A∗1 N.C./N.C.
C8 Ø8 —  
4-position
B∗1
C∗1
dual 3-port
N.O./N.O.
N.C./N.O. o Light/surge voltage suppressor C10 Ø 10 — — 
and common specification C12 Ø 12 — — 
∗1 Only the rubber seal type is available for the
4-position dual 3-port valve. Surge voltage Common One-touch fitting (Inch)
Symbol With light
suppressor specification Symbol A, B port SY3000 SY5000 SY7000
R — N1 Ø 1/8"  — —
Non-polar
e Seal type U
S

— Positive
N3 Ø 5/32" 





 N7 Ø 1/4"
0 Rubber seal
Z  common N9 Ø 5/16" —  
1 Metal seal
NS — Negative N11 Ø 3/8" — — 
NZ  common
∗ Select “R,” “U,” “S,” or “Z” for the valve when
r Pilot type the SI unit output polarity is — (positive !2 Thread type
— Internal pilot common). Select “R,” “U,” “NS,” or “NZ” for
R External pilot the valve when the SI unit output polarity is N — Rc
(negative common). F G
∗ For the non-polar type, be careful of surge N NPT

t Back pressure check valve voltage intrusion.


Refer to page 317 for details.
T NPTF
∗ Only — is available for M5.
(Built-in valve type) ∗ Only “Z” and “NZ” types are available with a
— None power saving circuit.
H Built-in
!3 Type of mounting screw
∗ Only the rubber seal type is available. A
manifold installed type is available if a back
!0 Manual override — Round head combination screw
pressure check valve with a metal seal is —: D: B Hexagon socket head cap screw
required. Refer to page 236 for ordering Non-locking Push-turn Round head combination screw
push type locking slotted K (Drop prevention type)
examples. However, it is not recommended
to use the built-in valve type and the manifold type
Hexagon socket head cap screw
installed type at the same time because it will H (Drop prevention type)
reduce the flow.
∗ The built-in valve type back pressure check ∗ For “K” and “H,” the valve body cover has a
valve is not available for the 3-position type drop prevention construction to stop the
or the SY7000. mounting screws from falling out when the
E: F: valve is removed for maintenance, etc.
Push-turn Slide locking ∗ When ordering a valve individually, the
y Pilot valve option locking lever
type
type base gasket is not included.
Since the base gasket is attached to the
— Standard (0.7 MPa) manifold, please order the base gasket
B Quick response type (0.7 MPa) separately if it is needed for maintenance.
K∗1 High pressure type (1.0 MPa) Refer to page 222 for base gasket and
∗1 Only the metal seal type is available for the mounting screw part numbers.
high pressure type. ∗ “B” and “H” cannot be selected for the
∗ Refer to page 36 for the safety slide locking individual SUP/EXH spacer assembly or
manual override. interface regulator.

Protective class
class # (Mark: )
152
Plug-in Connector Connecting Base
Type 10
Side Ported EX126
Type 11
Bottom Ported
SY3000/5000/7000 Series
RoHS
How to Order Manifolds

Refer to pages 180 (SY5000) and SS5Y 3 10 S4 V 05 U C6


181 (SY7000) for the dimensions
of Type 11/Bottom-ported type.
q w e r t y u i
q Series w Type r Valve stations
3 SY3000 10 Side ported Symbol Stations Note
5 SY5000 11 Bottom ported∗1 02 2 stations
Double wiring∗1


7 SY7000 ∗1 The SY5000 manifold base is used for the
bottom-ported SY3000. When ordering, 08 8 stations
refer to the “Plug-in Manifold Mixed 02 2 stations
Mounting Type” (from page 185). Specified layout∗2


(Up to 16 solenoids available)
16 16 stations
∗1 Double wiring: 2-position single, double,
e SI unit 3-position, and 4-position valves can be
0 Without SI unit used on all manifold stations.
V CC-Link (Positive common NPN) Use of a 2-position single solenoid will
result in an unused control signal. If this is
∗ Only a terminal block plate is mounted for the
not desired, order with a specified layout.
valve without SI unit.
∗2 Specified layout: Indicate the wiring
specifications with the manifold
specification sheet. (Note that 2-position
double, 3-position, and 4-position valves
cannot be used where single wiring has
How to Order Manifold Assembly been specified.)
∗ This also includes the number of the
blanking plate assembly.
Example (SS5Y3-10S4V--)

t P, E port entry
2-position double (24 VDC)
2-position single (24 VDC) SY3200-5U1 (1 set)
SY3100-5U1 (3 sets) U U side (2 to 10 stations)
3-position closed
SI unit centre (24 VDC)
D D side (2 to 10 stations)
SY3300-5U1 (1 set) B Both sides (2 to 16 stations)

y SUP/EXH block assembly


— Internal pilot
ide
Us S Internal pilot, Built-in silencer
s
on R External pilot
ati
St
3 ∗ 3/5(E) port is plugged for the built-in silencer
2 type.
1
ide ∗ When the built-in silencer type is used, keep
Ds the exhaust port from coming into direct
contact with water or other liquids.
Terminal block plate assembly
Manifold base (5 stations)
SS5Y3-10S4V-05D-C6

SS5Y3-10S4V-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.)


∗SY3100-5U1 ··················· 3 sets (2-position single part no.)
∗SY3200-5U1 ··················· 1 set (2-position double part no.)
∗SY3300-5U1 ··················· 1 set (3-position closed centre part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
• For the valve arrangement, the valve closest to the D side is considered the 1st station.
• Under the manifold part number, state the valves to be mounted in order starting
with the 1st station as shown in the figure above. If the arrangement becomes too For details on the EX126 Integrated Type (For Output)
complicated, specify the details on a manifold specification sheet. Serial Transmission System, refer to the Web Catalogue
∗ When mixing top-ported configurations, select from those listed on page 160. and the Operation Manual. For the part numbers of the SI
In such cases, use caution as there is also output on the A and B ports on units to be mounted, refer to page 217. Please download
the base side. the Operation Manual via the SMC website, https://www.
Specify on the manifold specification sheet if plugs are required for the A and
smc.eu
B ports on the base side.
153
Plug-in Connector Connecting Base SY3000/5000/7000 Series

u A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)


Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 Ø2  — — — — N1 Ø 1/8"  — — — —
C3 Ø 3.2  — — — — N3 Ø 5/32"   —  —

Straight
C4 Ø4   —  — N7 Ø 1/4"     
Straight

C6 Ø6      N9 Ø 5/16" —    
C8 Ø8 —     N11 Ø 3/8" — —  — 
C10 Ø 10 — —  —  CM∗1 Straight port, mixed sizes     
C12 Ø 12 — —  —  LN3 Ø 5/32"  — — — —

Upward
CM∗1 Straight port, mixed sizes      LN7 Ø 1/4"   — — —
L4 Ø4   — — — LN9 Ø 5/16" —  — — —
L6 Ø6    — — LN11 Ø 3/8" — —  — —
Upward

Elbow∗2

L8 Ø8 —   — — BN3 Ø 5/32"  — — — —
Downward

L10 Ø 10 — —  — — BN7 Ø 1/4"   — — —


L12 Ø 12 — —  — — BN9 Ø 5/16" —  — — —
Elbow∗2

B4 Ø4   — — — BN11 Ø 3/8" — —  — —
Downward

B6 Ø6    — — Elbow port, mixed sizes


LM∗1 (Including upward and    — —
B8 Ø8 —   — — downward piping)

B10 Ø 10 — —  — — P, E port size Ø


Ø 3/8" Ø 1/2" Ø 3/8" Ø 1/2"
B12 Ø 12 — —  — — (One-touch fittings) 5/16"
Elbow port, mixed sizes
LM∗1 (Including upward and    — —
downward piping)

P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).

i Mounting and Option


Option
Symbol Mounting
Name plate Station number
— — —
Direct
AA  
mounting
BA  —
D — —
DIN rail
A  
mounting
B  —
∗ Enter the number of stations inside  when it
is larger than the number of valve stations.
(Refer to “DIN Rail Option” below.)
∗ Only direct mounting is available for the type
11 bottom-ported type.
∗ Refer to page 319 for the fixation of DIN rail
mounting type manifold.

DIN Rail Option


— Standard length
0 Without DIN rail (with bracket)
3 For 3 stations Specify a longer rail

than the total length


16 For 16 stations of specified stations.

Protective class
class # (Mark: )
154
SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

q Series y Pilot valve option !0 Manual override


3 SY3000 — Standard (0.7 MPa) —: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K∗1 High pressure type (1.0 MPa) push type locking
∗1 Only the metal seal type is available for the slotted
high pressure type. type

w Type of actuation
1
2-position
Single u Coil type E: F:
2 Double — Standard
Push-turn Slide locking
3 Closed centre T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit lever
5 Pressure centre type if the valve is to be continuously type
A∗1 N.C./N.C. energised for long periods of time.
B∗1
4-position
N.O./N.O. ∗ Be careful of the energising time when the
dual 3-port power saving circuit is selected. Refer to
C∗1 N.C./N.O.
page 316 for details. ∗ Refer to page 36 for the safety slide locking
∗1 Only the rubber seal type is available for the manual override.
4-position dual 3-port valve.
i Rated voltage
e Seal type
5 24 VDC
!1 Type of mounting screw
— Round head combination screw
0 Rubber seal
B Hexagon socket head cap screw
1 Metal seal
o Light/surge voltage suppressor K Round head combination screw (Drop prevention type)
and common specification H Hexagon socket head cap screw (Drop prevention type)
Surge voltage Common ∗ For “K” and “H,” the valve body cover has a
r Pilot type Symbol With light
suppressor specification drop prevention construction to stop the
mounting screws from falling out when the
— Internal pilot R —
valve is removed for maintenance, etc.
Non-polar
R External pilot U  ∗ When ordering a valve individually, the

S — Positive base gasket is not included.
Z  common Since the base gasket is attached to the
∗ For the non-polar type, be careful of surge manifold, please order the base gasket
t Back pressure check valve voltage intrusion. separately if it is needed for maintenance.
(Built-in valve type) Refer to page 317 for details. Refer to page 222 for base gasket and
∗ Only “Z” type is available with a power saving mounting screw part numbers.
— None
circuit. ∗ “B” and “H” cannot be selected for the
H Built-in individual SUP/EXH spacer assembly,
∗ Only the rubber seal type is available. A interface regulator, or double check spacer
manifold installed type is available if a back assembly with residual pressure release
pressure check valve with a metal seal is valve.
required. Refer to page 236 for ordering
examples. However, it is not recommended
to use the built-in valve type and the manifold
installed type at the same time because it will
reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.

Protective class
class # (Mark: )
155
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY3000 Series Connector Connecting Base EX126

U C2
SS5Y3-10S4V- Stations D - C3, N1 ( )
D
B C4, N3 C6, N7
4 x G 1/2 One-touch fitting
Signal/Electrical entry [1(P), 3/5(E) port] One-touch fitting
Applicable tube O.D.: Ø 8, Ø 5/16" [4(A), 2(B) port]
2.6

SI Unit Applicable tube O.D.: Ø 2


: Ø 3.2, Ø 1/8"
(Station 1)---(Station n) : Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
90.7

1 P 1 P

63.1
13.6
10.6

56.6
55.4

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

21.6
4 A4 A4 A4 A4 A
18
13.2

(For DIN rail


33.4

(7.5)

mounting)
(Pitch)

(11.8)
Terminal block plate assembly 107.1 15.5 P = 10.5 (17.8)

D side U side
Manual override∗1
(L5) L1
DIN rail holding screw
(For DIN rail mounting)
(Light/surge voltage suppressor) (
Push-turn locking slotted type:
Press, then rotate it. )
DIN rail holding screw 4(A) port side : Blue (For rubber seal)
DIN rail : Grey (For metal seal)
(For DIN rail mounting)
2(B) port side : Yellow
(5.5)

(8)
B A B A B A B A B A
(35)

14 A 14 A 14 A 14 A 14 A 92.6
83
116

42
80

60.5
(40.9)
4.6

12 B 12 B 12 B 12 B 12 B
36.6
4.6
1.7
11

)
(4.9)

15.4
C6: 3.6
N7: 7.4

4 x M4 55.4
Mounting hole
2 x M5 Mounting hole
(

1 (Fitting for the type with P/E


7.1 88.2 L2 1.5 ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10S4V-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 164.3 174.8 185.3 195.8 206.3 216.8 227.3 237.8 248.3 258.8 269.3 279.8 290.3 300.8 311.3
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210
L3 198 198 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 335.5 335.5
L4 187.5 187.5 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 325 325
L5 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12

156
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY5000 Series Connector Connecting Base EX126

U C4, N3
SS5Y5-10S4V - Stations D - C6, N7 (D)
B C8, N9

One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 10, Ø 3/8"
4 x G 1/2
Signal/Electrical entry
One-touch fitting
[4(A), 2(B) port]
2.6

SI Unit (Station 1)----------- (Station n) Applicable tube O.D.: Ø 4, Ø 5/32"


: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
90.7

1 P 1 P

14.1

73.2
8.7
2 B2 B2 B2 B2 B

56.6
55.4

3/5 3/5
33.4

E E

29.1
4 A4 A4 A4 A4 A
13.2
12.4

(For DIN rail


33.4

(7.5)

mounting)
(Pitch)
(20.5)

(11.8)
Terminal block 108.8 18 P = 16
plate assembly

DIN rail holding screw


D side (For DIN rail mounting) U side
Manual override∗1
(L5) L1
DIN rail holding screw (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail (Light/surge voltage suppressor) : Grey (For metal seal)
2(B) port side : Yellow
(5.5)

(8)
B A B A B A B A B A
(35)

14 A 14 A 14 A 14 A 14 A
121.4
116

42
97.5
113.4
80

81.2
(61.7)
5.5

42.4

12 B 12 B 12 B 12 B 12 B

1
10.9
16.4

4.7
(5.9)
(8.3)

55.4
2 x M5 4 x M5 Mounting hole
Mounting hole
7.1 87.7 L2 1.5 (Fitting for the type with P/E
ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10S4V-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 181.3 197.3 213.3 229.3 245.3 261.3 277.3 293.3 309.3 325.3 341.3 357.3 373.3 389.3 405.3
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304
L3 210.5 223 248 260.5 273 285.5 310.5 323 335.5 360.5 373 385.5 398 423 435.5
L4 200 212.5 237.5 250 262.5 275 300 312.5 325 350 362.5 375 387.5 412.5 425
L5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14 12.5 17 15

157
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY7000 Series Connector Connecting Base EX126

U C6, N7
SS5Y7-10S4- Stations D - C8, N9 (D)
B C10, N11
C12
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 12, Ø 1/2"

4 x G1/2 SI unit
(2.6)

(Signal/Electrical entry) (Station 1) (Station n)

2
90.7

82.7
1 P 1 P
2 B2 B2 B2 B2 B

56.6
55.4

11.1
3/5 E 3/5 E
35.2

8.7

31.6
4 A4 A4 A4 A4 A
13.2
14.2

(For DIN rail


mounting)
(10)
(21.7)

(14.3)
33.4 (Pitch)
Terminal block
113.8 20.5 P = 19
plate assembly One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
: Ø 12

D side U side
(L5) L1 Manual override∗1
DIN rail
holding screw DIN rail holding screw (Light/surge voltage suppressor) (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN (For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
rail mounting) : Grey (For metal seal)
2(B) port side: Yellow

(8) (DIN rail)

B A B A B A B A B A
(35)

14 A 14 A 14 A 14 A 14 A
116

42
136.8

80

128.8
115
(5.5)

96.7
(77.1)

57.8

12 B 12 B 12 B 12 B 12 B
5.5
31.8

8.8

4 x M5
3.9
(6)
(9.3)

mounting hole 55.4


2 x M5 (A, B port: Ø 12)
(17.9)

1 (Fitting for the type with P/E


mounting hole
7.1 87.9 L2 1.5 ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10S4V-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 195.5 214.5 233.5 252.5 271.5 290.5 309.5 328.5 347.5 366.5 385.5 404.5 423.5 442.5 461.5
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360
L3 223 248 260.5 285.5 298 323 335.5 360.5 373 398 410.5 435.5 448 473 485.5
L4 212.5 237.5 250 275 287.5 312.5 325 350 362.5 387.5 400 425 437.5 462.5 475
L5 14 17 13.5 16.5 13.5 16.5 13 16 13 16 12.5 15.5 12.5 15.5 12

158
Plug-in Connector Connecting Base
EX126
Type 12
Top Ported
SY3000/5000/7000 Series
RoHS
How to Order Manifolds

Refer to pages 182 to 184


SS5Y 3 12S4 V 05 U
for the dimensions of
Type 12/Top-ported type.
q w e r t y u
q Series e Valve stations r P, E port entry
3 SY3000 Symbol Stations Note U∗1 U side (2 to 10 stations)
5 SY5000 02 2 stations D∗1 D side (2 to 10 stations)
Double wiring∗1

7 SY7000 B Both sides (2 to 16 stations)


08 8 stations ∗1 t For type “S”, SUP/EXH block assembly
02 2 stations with a built-in silencer, choose U or D for P,
w SI unit Specified layout∗2 E port entry.

(Up to 16 solenoids available)


0 Without SI unit 16 16 stations
V CC-Link (Positive common NPN) ∗1 Double wiring: 2-position single, double,
∗ Only a terminal block plate is mounted for the 3-position, and 4-position valves can be used t SUP/EXH block assembly
valve without SI unit. on all manifold stations. — Internal pilot
Use of a 2-position single solenoid will result S Internal pilot, Built-in silencer
in an unused control signal. If this is not R External pilot
desired, order with a specified layout.
∗2 Specified layout: Indicate the wiring ∗ The P and E ports are only available on the
specifications on the manifold specification U and D sides for the built-in silencer type.
sheet. (Note that 2-position double, 3-position, 3/5(E) port is plugged. The silencer exhaust
and 4-position valves cannot be used where port is located on the opposite side of the P
single wiring has been specified.) and E port entry. (Example: When the P and
∗ This also includes the number of the blanking E port entry is on the D side, the silencer
plate assembly. exhaust port is on the U side.)
∗ When the built-in silencer type is used, keep
the exhaust port from coming into direct
How to Order Manifold Assembly contact with water or other liquids.

Example (SS5Y3-12S4V--)
y P, E port size (One-touch fittings)
2-position double (24 VDC)
SY3230-5U1-C6 (1 set) Symbol SY3000 SY5000 SY7000
2-position single (24 VDC)
SY3130-5U1-C6 (3 sets) 3-position closed — Ø8 Ø 10 Ø 12
centre (24 VDC)
SI unit N Ø 5/16" Ø 3/8" Ø 1/2"
SY3330-5U1-C6 (1 set)
∗ For N, sizes are in inches.

u Mounting
e — Direct mounting
sid
s
U D DIN rail mounting (With DIN rail)
ation D0 DIN rail mounting (Without DIN rail)
St
2
3 D3 For 3 stations Specify a length

1 longer than that of


e
D sid D16 For 16 stations the standard rail.
∗ Refer to page 319 for the fixation of DIN rail
Terminal block plate assembly mounting type manifold.
Manifold base (5 stations)
SS5Y3-12S4V-05D

SS5Y3-12S4V-05D ··· 1 set (Type 12 5-station manifold base part no.)


∗SY3130-5U1-C6 ········ 3 sets (2-position single part no.)
∗SY3230-5U1-C6 ········ 1 set (2-position double part no.)
∗SY3330-5U1-C6 ········ 1 set (3-position closed centre part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
• For the valve arrangement, the valve closest to the D side is considered the 1st station. For details on the EX126 Integrated Type (For Output) Serial
• Under the manifold part number, state the valves to be mounted in order starting Transmission System, refer to the Web Catalogue and the
with the 1st station as shown in the figure above. If the arrangement becomes too Operation Manual. For the part numbers of the SI units to be
complicated, specify the details on a manifold specification sheet. mounted, refer to page 217. Please download the Operation
Manual via the SMC website, https://www.smc.eu

159
Plug-in Connector Connecting Base SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported

q Series y Pilot valve option !1 A, B port size


3 SY3000 — Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K∗1 High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗1 Only the metal seal type is available for the 01 1/8 SY5000
high pressure type. 02 1/4 SY7000

w Type of actuation u Coil type


One-touch fitting (Metric)
1 Single Symbol A, B port SY3000 SY5000 SY7000
2-position — Standard C2 Ø2  — —
2 Double
3 Closed centre T With power saving circuit (Continuous duty type) C3 Ø 3.2  — —
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit C4 Ø4   —
type if the valve is to be continuously C6 Ø6   
5 Pressure centre
energised for long periods of time.
A∗1 N.C./N.C. C8 Ø8 —  
4-position ∗ Be careful of the energising time when the
B∗1 N.O./N.O. power saving circuit is selected. Refer to C10 Ø 10 — — 
dual 3-port
C∗1 N.C./N.O. page 316 for details. C12 Ø 12 — — 
∗1 Only the rubber seal type is available for the One-touch fitting (Inch)
4-position dual 3-port valve.
i Rated voltage Symbol A, B port SY3000 SY5000 SY7000
N1 Ø 1/8"  — —
5 24 VDC
N3 Ø 5/32"   —
e Seal type N7 Ø 1/4"   
N9 Ø 5/16" —  
0
1
Rubber seal
Metal seal
o Light/surge voltage suppressor N11 Ø 3/8" — — 
and common specification
Surge voltage Common
Symbol With light
suppressor specification
r Pilot type R — !2 Thread type
Non-polar
— Internal pilot U  — Rc
 F G
R External pilot S — Positive
Z  common N NPT
∗ For the non-polar type, be careful of surge T NPTF
voltage intrusion. ∗ Only — is available for M5.
t Back pressure check valve Refer to page 317 for details.
(Built-in valve type) ∗ Only “Z” type is available with a power saving
circuit.
— None
H Built-in !3 Type of mounting screw
∗ Only the rubber seal type is available. A — Round head combination screw
manifold installed type is available if a back !0 Manual override B Hexagon socket head cap screw
pressure check valve with a metal seal is
—: D: K Round head combination screw (Drop prevention type)
required. Refer to page 236 for ordering
Non-locking Push-turn H Hexagon socket head cap screw (Drop prevention type)
examples. However, it is not recommended
push type locking slotted ∗ For “K” and “H,” the valve body cover has a
to use the built-in valve type and the manifold
type drop prevention construction to stop the
installed type at the same time because it will
reduce the flow. mounting screws from falling out when the
∗ The built-in valve type back pressure check valve is removed for maintenance, etc.
valve is not available for the 3-position type ∗ When ordering a valve individually, the
or the SY7000. base gasket is not included.
E: F: Since the base gasket is attached to the
Push-turn Slide locking manifold, please order the base gasket
locking lever type separately if it is needed for maintenance.
type Refer to page 222 for base gasket and
mounting screw part numbers.
∗ “B” and “H” cannot be selected for the
individual SUP/EXH spacer assembly or
interface regulator.

∗ Refer to page 36 for the safety slide locking


manual override.

Protective class
class # (Mark: )
160
Plug-in Connector Connecting Base
Type 10
Side Ported EX120
Type 11
Bottom Ported
SY3000/5000/7000 Series
RoHS
How to Order Manifolds

Refer to pages 180 (SY5000) and SS5Y 3 10 S3 R1 05 U C6


181 (SY7000) for the dimensions
of Type 11/Bottom-ported type.
q w e r t y u i
q Series e SI unit r Valve stations
3 SY3000 0 Without SI unit Symbol Stations Note
5 SY5000 Q DeviceNet™ (Positive common NPN) 02 2 stations
Double wiring∗1


7 SY7000 R1 OMRON CompoBus/S 16 outputs
R2 (Positive common NPN) 8 outputs 08 8 stations
V CC-Link (Positive common NPN) 02 2 stations
w Type ZB∗1
Specified layout∗2


Positive common NPN
CompoNet™ (Up to 16 solenoids available)
10 Side ported ZBN∗1 Negative common PNP 16 16 stations
11 Bottom ported∗1 ∗1 The communication connector (for the ∗1 Double wiring: 2-position single, double,
∗1 The SY5000 manifold base is used for the opposite side) is not provided. Please order 3-position, and 4-position valves can be
bottom-ported SY3000. When ordering, it separately. used on all manifold stations.
refer to the “Plug-in Manifold Mixed ∗ Ensure a match with the common Use of a 2-position single solenoid will
Mounting Type” (from page 185). specification of the valve to be used. result in an unused control signal. If this is
not desired, order with a specified layout.
∗2 Specified layout: Indicate the wiring
specifications on the manifold specification
sheet. (Note that 2-position double,
3-position, and 4-position valves cannot be
used where single wiring has been
specified.)
How to Order Manifold Assembly ∗ This also includes the number of the blanking
plate assembly.
∗ Since R2 type SI unit has 8 outputs, note that
Example (SS5Y3-10S3V-) up to 8 solenoids can be accommodated.

2-position double (24 VDC)


2-position single (24 VDC) SY3200-5U1 (1 set)
SY3100-5U1 (3 sets) 3-position closed t P, E port entry
centre (24 VDC) U U side (2 to 10 stations)
SY3300-5U1 (1 set) D D side (2 to 10 stations)
B Both sides (2 to 16 stations)

y SUP/EXH block assembly


— Internal pilot
ide S Internal pilot, Built-in silencer
Us
on
s R External pilot
ati
St ∗ 3/5(E) port is plugged for the built-in silencer
3 type.
2
1
e
D sid
Manifold base (5 stations)
SS5Y3-10S3V-05D-C6

SS5Y3-10S3V-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.)


∗SY3100-5U1 ··················· 3 sets (2-position single part no.)
∗SY3200-5U1 ··················· 1 set (2-position double part no.)
∗SY3300-5U1 ··················· 1 set (3-position closed centre part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
• For the valve arrangement, the valve closest to the D side is considered the 1st station.
• Under the manifold part number, state the valves to be mounted in order starting
with the 1st station as shown in the figure above. If the arrangement becomes too
complicated, specify the details on a manifold specification sheet. For details on the EX120 Integrated Type (For Output) Serial
∗ When mixing top-ported configurations, select from those listed on page 168. Transmission System, refer to the Web Catalogue and the
In such cases, use caution as there is also output on the A and B ports on Operation Manual. For the part numbers of the SI units to be
the base side. mounted, refer to page 218. Please download the Operation
Specify on the manifold specification sheet if plugs are required for the A and Manual via the SMC website, https://www.smc.eu
B ports on the base side.
161
Plug-in Connector Connecting Base SY3000/5000/7000 Series

u A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)


Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 Ø2  — — — — N1 Ø 1/8"  — — — —
C3 Ø 3.2  — — — — N3 Ø 5/32"   —  —

Straight
C4 Ø4   —  — N7 Ø 1/4"     
Straight

C6 Ø6      N9 Ø 5/16" —    
C8 Ø8 —     N11 Ø 3/8" — —  — 
C10 Ø 10 — —  —  CM∗1 Straight port, mixed sizes     
C12 Ø 12 — —  —  LN3 Ø 5/32"  — — — —

Upward
CM∗1 Straight port, mixed sizes      LN7 Ø 1/4"   — — —
L4 Ø4   — — — LN9 Ø 5/16" —  — — —
L6 Ø6    — — LN11 Ø 3/8" — —  — —
Upward

Elbow∗2

L8 Ø8 —   — — BN3 Ø 5/32"  — — — —
Downward

L10 Ø 10 — —  — — BN7 Ø 1/4"   — — —


L12 Ø 12 — —  — — BN9 Ø 5/16" —  — — —
Elbow∗2

B4 Ø4   — — — BN11 Ø 3/8" — —  — —
Downward

B6 Ø6    — — Elbow port, mixed sizes


LM∗1 (Including upward and    — —
B8 Ø8 —   — — downward piping)

B10 Ø 10 — —  — — P, E port size Ø


Ø 3/8" Ø 1/2" Ø 3/8" Ø 1/2"
B12 Ø 12 — —  — — (One-touch fittings) 5/16"
Elbow port, mixed sizes
LM∗1 (Including upward and    — —
downward piping)

P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).

i Mounting and Option


Option
Symbol Mounting
Name plate Station number
— — —
Direct
AA  
mounting
BA  —
D — —
DIN rail
A  
mounting
B  —
∗ Enter the number of stations inside  when it
is larger than the number of valve stations.
(Refer to “DIN Rail Option” below.)
∗ Only direct mounting is available for the type
11 bottom-ported type.
∗ Refer to page 319 for the fixation of DIN rail
mounting type manifold.

DIN Rail Option


— Standard length
0 Without DIN rail (with bracket)
3 For 3 stations Specify a longer rail

than the total length


16 For 16 stations of specified stations.
∗ If the DIN rail must be mounted without an SI
unit, select D0. Then, refer to L3 of the
dimensions for the DIN rail length and order
separately. (Refer to page 227 for the DIN Protective class
rail part number.) class # (Mark: )
162
SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

q Series y Pilot valve option !0 Manual override


3 SY3000 — Standard (0.7 MPa) —: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K∗1 High pressure type (1.0 MPa) push type locking
∗1 Only the metal seal type is available for the slotted
high pressure type. type
w Type of actuation
1
2-position
Single u Coil type
2 Double — Standard
E: F:
3 Closed centre T With power saving circuit (Continuous duty type) Push-turn Slide locking
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit locking type
5 Pressure centre type if the valve is to be continuously lever
A∗1 N.C./N.C. energised for long periods of time. type
B∗1
4-position
N.O./N.O. ∗ Be careful of the energising time when the
dual 3-port power saving circuit is selected. Refer to
C∗1 N.C./N.O.
page 316 for details.
∗1 Only the rubber seal type is available for the ∗ Refer to page 36 for the safety slide locking
4-position dual 3-port valve.
i Rated voltage manual override.

5 24 VDC
e Seal type !1 Type of mounting screw
0 Rubber seal
1 Metal seal o Light/surge voltage suppressor —
B
Round head combination screw
Hexagon socket head cap screw
and common specification K Round head combination screw (Drop prevention type)
Surge voltage Common
r Pilot type Symbol With light
suppressor specification
H Hexagon socket head cap screw (Drop prevention type)
∗ For “K” and “H,” the valve body cover has a
— Internal pilot R — drop prevention construction to stop the
Non-polar
R External pilot U  mounting screws from falling out when the
S — Positive valve is removed for maintenance, etc.
 ∗ When ordering a valve individually, the
Z  common
t Back pressure check valve NS — Negative
base gasket is not included.
(Built-in valve type) Since the base gasket is attached to the
NZ  common
manifold, please order the base gasket
— None ∗ Select “R,” “U,” “S,” or “Z” for the valve when separately if it is needed for maintenance.
H Built-in the SI unit specification is positive common. Refer to page 222 for base gasket and
∗ Only the rubber seal type is available. A Select “R,” “U,” “NS,” or “NZ” for the valve mounting screw part numbers.
manifold installed type is available if a back when the SI unit specification is ZBN ∗ “B” and “H” cannot be selected for the
pressure check valve with a metal seal is (negative common). individual SUP/EXH spacer assembly,
required. Refer to page 236 for ordering ∗ For the non-polar type, be careful of surge interface regulator, or double check spacer
examples. However, it is not recommended voltage intrusion. assembly with residual pressure release
to use the built-in valve type and the manifold Refer to page 317 for details. valve.
installed type at the same time because it will ∗ Only “Z” and “NZ” types are available with a
reduce the flow. power saving circuit.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.

Protective class
class # (Mark: )
163
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY3000 Series Connector Connecting Base EX120

C2
U
SS5Y3-10S3- Stations D - C3, N1
C4, N3 (D)
B C6, N7

One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 2
One-touch fitting
(Station 1)---(Station n) : Ø 3.2, Ø 1/8"
[1(P), 3/5(E) port]
: Ø 4, Ø 5/32"
Applicable tube O.D.: Ø 8, Ø 5/16"
: Ø 6, Ø 1/4"

1 P 1 P

10.6
13.6

63.1
56.6
61

3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2

21.6
4 A4 A4 A4 A4 A
18

(For DIN rail


mounting)
7.5
(Pitch)

11.8
39.7 15.5 P = 10.5 (17.8)

D side U side
Manual override∗1
DIN rail holding screw (L5) L1
(For DIN rail mounting) (
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
Light/surge voltage suppressor : Grey (For metal seal)
2(B) port side : Yellow
5.5

8
B A B A B A B A B A
92.6

14 A 14 A 14 A 14 A 14 A
64

35
83

6.2
60.5
40.9

12 B 12 B 12 B 12 B 12 B

M3
Terminal screw
16.1

4.6
4.6

1.7
)
(4.9)
C6: 3.6
N7: 7.4

4 x M4 mounting hole
(

(Fitting for the type with P/E


27.9 L2 1.5
ports on the U and/or D sides)
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3

∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10S3V-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 96.9 107.4 117.9 128.4 138.9 149.4 159.9 170.4 180.9 191.4 201.9 212.4 222.9 233.4 243.9
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210
L3 123 135.5 148 160.5 173 173 185.5 198 210.5 223 235.5 235.5 248 260.5 273
L4 112.5 125 137.5 150 162.5 162.5 175 187.5 200 212.5 225 225 237.5 250 262.5
L5 13 14 15 16 17 12 13 14 15 16 17 11.5 12.5 13.5 14.5

164
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY5000 Series Connector Connecting Base EX120

U C4, N3
SS5Y5-10S3- Stations D - C6, N7 (D)
B C8, N9

One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 4, Ø 5/32"
One-touch fitting (Station 1)----------- (Station n) : Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 10, Ø 3/8"

1 P 1 P

73.2
2 B2 B2 B2 B2 B

56.6
61

14.1
33.4

3/5 E 3/5 E

29.1
4 A4 A4 A4 A4 A
12.4
8.7

(For DIN rail


7.5

mounting)
(Pitch)

11.8
44.2 18 P = 16 (20.5)

D side U side
Manual override∗1
(L5) L1
DIN rail holding screw
(For DIN rail mounting)
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
DIN rail Light/surge voltage suppressor : Grey (For metal seal) M3
2(B) port side : Yellow Terminal screw

8
5.5

6.2
BA BA BA BA BA
64

14 A 14 A 14 A 14 A 14 A
35
97.5

113.4
81.2
61.7
36.9

5.5

12 B 12 B 12 B 12 B 12 B
10.9

4.7
(5.9)
(8.3)

4 x M5 mounting hole

30.2 L2 1.5 (Fitting for the type with P/E


ports on the U and/or D sides)
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3

∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10S3V-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 116.7 132.7 148.7 164.7 180.7 196.7 212.7 228.7 244.7 260.7 276.7 292.7 308.7 324.7 340.7
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304
L3 148 160.5 173 198 210.5 223 248 260.5 273 285.5 310.5 323 335.5 348 373
L4 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5 275 300 312.5 325 337.5 362.5
L5 15.5 14 12 16.5 15 13 17.5 16 14 12.5 17 15 13.5 11.5 16

165
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY7000 Series Connector Connecting Base EX120

C6, N7
U
SS5Y7-10S3- Stations D - C8, N9
C10, N11 (D)
B C12

(Station 1) (Station n)
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 12, Ø 1/2"

2
82.7
1 P 1 P
2 B2 B2 B2 B2 B

56.6
61

11.1
3/5 E 3/5 E
35.2

8.7

31.6
4 A4 A4 A4 A4 A
14.2

(For DIN rail


(10)
(21.7)

mounting)
(14.3)
(Pitch)
47.7 20.5 P = 19
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
: Ø 12

D side U side
Manual override∗1
(L5) L1
DIN rail holding screw (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
(Light/surge voltage suppressor) : Grey (For metal seal)
2(B) port side: Yellow

(8)
(DIN rail)

B A B A B A B A B A
(35)
64

14 A 14 A 14 A 14 A 14 A

6.2
128.8
115
(5.5)

96.7
(77.1)
50.8

12 B 12 B 12 B 12 B 12 B
5.5

8.8
3.9
(6)
(9.3)

M3
(17.9)

(A, B port: Ø 12) 4 x M5 mounting hole Terminal screw


(Fitting for the type with P/E
28.9 L2 1.5 ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10S3V-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 129.4 148.4 167.4 186.4 205.4 224.4 243.4 262.4 281.4 300.4 319.4 338.4 357.4 376.4 395.4
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360
L3 160.5 173 198 210.5 235.5 248 273 285.5 310.5 335.5 348 373 385.5 410.5 423
L4 150 162.5 187.5 200 225 237.5 262.5 275 300 325 337.5 362.5 375 400 412.5
L5 15.5 12.5 15.5 12 15 12 15 11.5 14.5 17.5 14.5 17.5 14 17 14

166
Plug-in Connector Connecting Base
EX120
Type 12
Top Ported
SY3000/5000/7000 Series
RoHS
How to Order Manifolds

Refer to pages 182 to 184


SS5Y 3 12S3 R1 05 U
for the dimensions of
Type 12/Top-ported type.
q w e r t y u
q Series e Valve stations r P, E port entry
3 SY3000 Symbol Stations Note U∗1 U side (2 to 10 stations)
5 SY5000 02 2 stations D∗1 D side (2 to 10 stations)
Double wiring∗1

7 SY7000 B Both sides (2 to 16 stations)


08 8 stations ∗1 t For type “S”, SUP/EXH block assembly
02 2 stations with a built-in silencer, choose U or D for P,
Specified layout∗2
w SI unit E port entry.

(Up to 16 solenoids available)


0 Without SI unit 16 16 stations
Q DeviceNet™ (Positive common NPN) ∗1 Double wiring: 2-position single, double,
R1 OMRON CompoBus/S 16 outputs 3-position, and 4-position valves can be used t SUP/EXH block assembly
R2 (Positive common NPN) 8 outputs on all manifold stations. — Internal pilot
Use of a 2-position single solenoid will result S Internal pilot, Built-in silencer
V CC-Link (Positive common NPN)
in an unused control signal. If this is not
ZB∗1 Positive common NPN desired, order with a specified layout. R External pilot
CompoNet™
ZBN∗1 Negative common PNP ∗2 Specified layout: Indicate the wiring ∗ The P and E ports are only available on the
∗1 The communication connector (for the specifications on the manifold specification U and D sides for the built-in silencer type.
opposite side) is not provided. Please order sheet. (Note that 2-position double, 3-position, 3/5(E) port is plugged. The silencer exhaust
it separately. and 4-position valves cannot be used where port is located on the opposite side of the P
∗ Ensure a match with the common single wiring has been specified.) and E port entry. (Example: When the P and
specification of the valve to be used. ∗ This also includes the number of the blanking E port entry is on the D side, the silencer
plate assembly. exhaust port is on the U side.)
∗ Since R2 type SI unit has 8 outputs, note that
up to 8 solenoids can be accommodated.

How to Order Manifold Assembly y P, E port size (One-touch fittings)


Symbol SY3000 SY5000 SY7000
Example (SS5Y3-12S3V-) — Ø8 Ø 10 Ø 12
2-position double (24 VDC)
N Ø 5/16" Ø 3/8" Ø 1/2"
SY3230-5U1-C6 (1 set)
2-position single (24 VDC) ∗ For N, sizes are in inches.
SY3130-5U1-C6 (3 sets) 3-position closed
centre (24 VDC)
SY3330-5U1-C6 (1 set)
u Mounting
— Direct mounting
D DIN rail mounting (With DIN rail)
D0 DIN rail mounting (Without DIN rail)
D3 For 3 stations Specify a length
ide

Us longer than that of


s
tio
n D16 For 16 stations the standard rail.
a
St
3 ∗ If the DIN rail must be mounted without an SI
2 unit, select D0. Then, refer to L3 of the
1
Manifold base e dimensions for the DIN rail length and order
(5 stations) D sid
separately. (Refer to page 227 for the DIN
SS5Y3-12S3V-05D rail part number.)
∗ Refer to page 319 for the fixation of DIN rail
SS5Y3-12S3V-05D ··· 1 set (Type 12 5-station manifold base part no.) mounting type manifold.
∗SY3130-5U1-C6 ······· 3 sets (2-position single part no.)
∗SY3230-5U1-C6 ······· 1 set (2-position double part no.)
∗SY3330-5U1-C6 ······· 1 set (3-position closed centre part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
For details on the EX120 Integrated Type (For Output) Serial
• For the valve arrangement, the valve closest to the D side is considered the 1st station. Transmission System, refer to the Web Catalogue and the
• Under the manifold part number, state the valves to be mounted in order starting Operation Manual. For the part numbers of the SI units to be
with the 1st station as shown in the figure above. If the arrangement becomes too mounted, refer to page 218. Please download the Operation
complicated, specify the details on a manifold specification sheet. Manual via the SMC website, https://www.smc.eu

167
Plug-in Connector Connecting Base SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported

q Series y Pilot valve option !1 A, B port size


3 SY3000 — Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K∗1 High pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗1 Only the metal seal type is available for the 01 1/8 SY5000
high pressure type. 02 1/4 SY7000
w Type of actuation One-touch fitting (Metric)
1 Single
2
2-position
Double u Coil type Symbol A, B port SY3000 SY5000 SY7000

C2 Ø2 — —
3 Closed centre — Standard
C3 Ø 3.2  — —
4 3-position Exhaust centre T With power saving circuit (Continuous duty type)
C4 Ø4   —
5 Pressure centre ∗ Be sure to select the power saving circuit
C6 Ø6   
A∗1 N.C./N.C. type if the valve is to be continuously
4-position energised for long periods of time. C8 Ø8 —  
B∗1 N.O./N.O.

dual 3-port ∗ Be careful of the energising time when the C10 Ø 10 — —
C∗1 N.C./N.O.
power saving circuit is selected. Refer to C12 Ø 12 — — 
∗1 Only the rubber seal type is available for the page 316 for details.
4-position dual 3-port valve. One-touch fitting (Inch)
Symbol A, B port SY3000 SY5000 SY7000
i Rated voltage N1 Ø 1/8"  — —
e Seal type 5 24 VDC N3 Ø 5/32"   —
0 Rubber seal N7 Ø 1/4"   
1 N9 Ø 5/16" —  
o Light/surge voltage suppressor
Metal seal
N11 Ø 3/8" — — 
and common specification
r Pilot type Surge voltage Common
— Internal pilot
Symbol With light
suppressor specification !2 Thread type
R External pilot R — — Rc
Non-polar
U  F G
S — Positive N NPT

t Back pressure check valve Z
NS


common T NPTF
(Built-in valve type) Negative ∗ Only — is available for M5.
NZ  common
— None
∗ Select “R,” “U,” “S,” or “Z” for the valve when
H Built-in
∗ Only the rubber seal type is available. A
the SI unit specification is positive common.
Select “R,” “U,” “NS,” or “NZ” for the valve
!3 Type of mounting screw
manifold installed type is available if a back when the SI unit specification is ZBN — Round head combination screw
pressure check valve with a metal seal is (negative common). B Hexagon socket head cap screw
required. Refer to page 236 for ordering ∗ For the non-polar type, be careful of surge K Round head combination screw (Drop prevention type)
examples. However, it is not recommended voltage intrusion. H Hexagon socket head cap screw (Drop prevention type)
to use the built-in valve type and the manifold Refer to page 317 for details.
installed type at the same time because it will ∗ For “K” and “H,” the valve body cover has a
∗ Only “Z” and “NZ” types are available with a
reduce the flow. drop prevention construction to stop the
power saving circuit.
∗ The built-in valve type back pressure check mounting screws from falling out when the
valve is not available for the 3-position type valve is removed for maintenance, etc.
or the SY7000. !0 Manual override ∗ When ordering a valve individually, the
base gasket is not included.
—: D: Since the base gasket is attached to the
Non-locking Push-turn manifold, please order the base gasket
push type locking slotted separately if it is needed for maintenance.
type Refer to page 222 for base gasket and
mounting screw part numbers.
∗ “B” and “H” cannot be selected for the
individual SUP/EXH spacer assembly or
interface regulator.

E: F:
Push-turn Slide locking
locking lever type
type

∗ Refer to page 36 for the safety slide locking


manual override. Protective class
class # (Mark: )
168
Plug-in Connector Connecting Base
Type 10
Side Ported EX180

SY3000/5000/7000 Series
Type 11
Bottom Ported

How to Order Manifolds

Refer to pages 180 (SY5000) and SS5Y 3 10 S 8 Q 05 U C6


181 (SY7000) for the dimensions
of Type 11/Bottom-ported type. q w e r t y u i o
q Series r SI unit output polarity, Number of outputs y Valve stations
3 SY3000 32 outputs 16 outputs In the case of the 32-output SI unit
5 SY5000 Without SI unit — Symbol Stations Note
7 SY7000 Positive common (NPN) 2 3 02 2 stations
Double wiring∗1


Negative common (PNP) 4 5
∗ When “V” (CC-Link) is selected for the SI 16 16 stations
w Type unit, only symbol “2” or “4” (32 outputs) can 02 2 stations
Specified layout∗2


10 Side ported be selected. (Up to 32 solenoids available)
11 Bottom ported∗1 ∗ Ensure a match with the common specifica- 24 24 stations
∗1 The SY5000 manifold base is used for the tion of the valves to be used. In the case of the 16-output SI unit
bottom ported SY3000. When ordering,
Symbol Stations Note
refer to the “Plug-in Manifold Mixed
Mounting Type” (Refer to page 185). t Communication connector 02 2 stations
Double wiring∗1


— T-branch type
08 8 stations
e SI unit A Straight type
∗ The communication connector and power
02 2 stations

Specified layout∗2

0 Without SI unit
connector are shipped together with the (Up to 16 solenoids available)
Q DeviceNet™ manifold. The power connector is only availa-
16 16 stations
V CC-Link ble for the straight type. ∗1 Double wiring: 2-position single, double,
∗ Only the connector block assembly is ∗ When not selecting an SI unit, the symbol will 3-position, and 4-position valves can be
mounted for models without an SI unit. be “—.” used on all manifold stations.
Use of a 2-position single solenoid will result
in an unused control signal. If this is not
desired, order with a specified layout.
How to Order Manifold Assembly ∗2 Specified layout: Indicate the wiring
specifications on the manifold specification
sheet. (Note that 2-position double, 3-position,
Example (SS5Y3-10S8-) and 4-position valves cannot be used where
single wiring has been specified.)
2-position double (24 VDC) 3-position closed centre (24 VDC) ∗ This also includes the number of the blanking
SY3200-5U1 (1 set) SY3300-5U1 (1 set) plate assembly.
∗ For the product without the SI unit (S80),
2-position single (24 VDC)
note the maximum number of solenoids of
SY3100-5U1 (3 sets)
the SI unit that will be mounted. If the layout
is specified, indicate it on the manifold
ide
specification sheet.
Us
u P, E port entry, SUP/EXH block assembly
s
n
tio
ta
S

23 P, E port entry Internal pilot


Internal pilot,
External pilot
1 Built-in silencer
ide
Manifold base (5 stations) Ds U side (2 to 10 stations) U C G
SS5Y3-10S8V2-05D-C6 D side (2 to 10 stations) D E H
Both sides (2 to 24 stations) B F J
SS5Y3-10S8V2-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.) ∗ 3/5(E) port is plugged for the built-in silencer type.
∗SY3100-5U1 ······················ 3 sets (2-position single part no.) ∗ When the built-in silencer type is used, keep the exhaust port from
∗SY3200-5U1 ······················ 1 set (2-position double part no.) coming in direct contact with water or other liquids.
∗SY3300-5U1 ······················ 1 set (3-position closed centre part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
• For the valve arrangement, the valve closest to the D side is considered the 1st station.
• Under the manifold part number, state the valves to be mounted in order starting
with the 1 st station as shown in the figure above. If the arrangement becomes For details on the EX180 Integrated Type (For Output) Serial
too complicated, specify the details on a manifold specification sheet. Transmission System, refer to the Web Catalogue and the
Operation Manual. For the part numbers of the SI units to be
∗ When mixing top-ported configurations, select from those listed on page 176.
In such cases, use caution as there is also output on the A and B ports on the base side. mounted, refer to page 219. Please download the Operation
Specify on the manifold specification sheet if plugs are required for the A and B Manual via the SMC website:
ports on the base side. https://www.smc.eu

169
Plug-in Connector Connecting Base SY3000/5000/7000 Series

i A, B port size (Metric/One-touch fitting) A, B port size (Inch/One-touch fitting)


Type 10/Side ported Type 11/Bottom ported Type 10/Side ported Type 11/Bottom ported
Symbol A, B port Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000 SY3000 SY5000 SY7000 SY5000 SY7000
C2 Ø2  — — — — N1 Ø 1/8"  — — — —
C3 Ø 3.2  — — — — N3 Ø 5/32"   —  —

Straight
C4 Ø4   —  — N7 Ø 1/4"     
Straight

C6 Ø6      N9 Ø 5/16" —    
C8 Ø8 —     N11 Ø 3/8" — —  — 
C10 Ø 10 — —  —  CM∗1 Straight port, mixed sizes     
C12 Ø 12 — —  —  LN3 Ø 5/32"  — — — —

Upward
CM∗1 Straight port, mixed sizes      LN7 Ø 1/4"   — — —
L4 Ø4   — — — LN9 Ø 5/16" —  — — —
L6 Ø6    — — LN11 Ø 3/8" — —  — —
Upward

Elbow∗2

L8 Ø8 —   — — BN3 Ø 5/32"  — — — —
Downward

L10 Ø 10 — —  — — BN7 Ø 1/4"   — — —


L12 Ø 12 — —  — — BN9 Ø 5/16" —  — — —
Elbow∗2

B4 Ø4   — — — BN11 Ø 3/8" — —  — —
Downward

B6 Ø6    — — Elbow port, mixed sizes


LM∗1 (Including upward and    — —
B8 Ø8 —   — — downward piping)

B10 Ø 10 — —  — — P, E port size Ø


Ø 3/8" Ø 1/2" Ø 3/8" Ø 1/2"
B12 Ø 12 — —  — — (One-touch fittings) 5/16"
Elbow port, mixed sizes
LM∗1 (Including upward and    — —
downward piping)

P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 231).

o Mounting and Option


Option DIN Rail Option
Symbol Mounting
Name plate Station number — Standard length
— — — 0 Without DIN rail (with bracket)
Direct 3 For 3 stations Specify a longer
AA mounting  
rail than the total
···

···

BA  — length of specified
D — — 24 For 24 stations stations.
DIN rail
A mounting  
B  —
∗ Enter the number of stations inside  when it is larger than the number
of valve stations. (Refer to “DIN Rail Option” above.)
∗ Only direct mounting is available for Type 11 (Bottom ported).
∗ Refer to page 319 for the fixation of DIN rail mounting type manifold.

Protective class
class # (Mark: )
170
SY3000/5000/7000 Series
Refer to page 17 for valve
How to Order Valves (With mounting screw) specifications.

SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

q Series y Pilot valve option !0 Manual override


3 SY3000 — Standard (0.7 MPa) —: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K∗1 High-pressure type (1.0 MPa) push type locking
∗1 Only the metal seal type is available for the slotted
high-pressure type. type

w Type of actuation
1
2-position
Single u Coil type E: F:
2 Double — Standard Push-turn Slide locking
3 Closed centre T With power-saving circuit (Continuous duty type) locking type
4 3-position Exhaust centre ∗ Be sure to select the power-saving circuit lever
5 Pressure centre type when the valve is to be continuously type
A∗1 N.C./N.C. energised for long periods of time.
B∗1
4-position
N.O./N.O. ∗ Be careful of the energising time when the
dual 3-port power-saving circuit is selected. Refer to
C∗1 N.C./N.O.
page 316 for details. ∗ Refer to page 36 for the safety slide locking
∗1 Only the rubber seal type is available for the manual override.
4-position dual 3-port valve.
i Rated voltage
5 24 VDC
!1 Type of mounting screw
e Seal type — Round head combination screw
0 Rubber seal B Hexagon socket head cap screw
1 Metal seal o Light/surge voltage suppressor K Round head combination screw (Drop prevention type)
and common specification H Hexagon socket head cap screw (Drop prevention type)
Surge voltage Common ∗ For “K” and “H,” the valve body cover has a
Symbol With light
r Pilot type R —
suppressor specification drop prevention construction to stop the
mounting screws from falling out when the
— Internal pilot Non-polar valve is removed for maintenance, etc.
U 
R External pilot ∗ When ordering a valve individually, the
S — Positive base gasket is not included.

Z  common Since the base gasket is attached to the
NS — Negative manifold, please order the base gasket
t Back pressure check valve NZ  common separately if it is needed for maintenance.
Refer to page 222 for base gasket and
(Built-in valve type) ∗ Select “R,” “U,” “S,” or “Z” for the valve when
mounting screw part numbers.
the SI unit output polarity is positive common.
— None ∗ “B” and “H” cannot be selected for the
Select “R,” “U,” “NS,” or “NZ” for the valve
H Built-in
when the SI unit output polarity is negative
individual SUP/EXH spacer assembly,
∗ Only the rubber seal type is available. A interface regulator, or double check spacer
common.
assembly with residual pressure release
manifold installed type is available if a back ∗ Only “Z” and “NZ” are available with a
pressure check valve with a metal seal is valve.
power-saving circuit.
required. Refer to page 236 for ordering
examples. However, it is not recommended
to use the built-in valve type and the manifold
installed type at the same time because it will
reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.

Protective class
class # (Mark: )
171
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY3000 Series Connector Connecting Base EX180

C2
U
SS5Y3-10S8- Stations D - C3, N1
C4, N3 (D)
B C6, N7

Communication connector
Shipped together with the manifold
One-touch fitting
[1(P), 3/5(E) port]
Applicable tubing O.D.: Ø 8, Ø 5/16"

One-touch fitting
(Station 1) (Station n)
[4(A), 2(B) port]
Ground terminal SI unit Applicable tubing O.D.: Ø 2
M3 : Ø 3.2, Ø 1/8"
: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
(Straight type: 55.2)
(65.4)

10.6

13.6

63.1
56.6
40.2

21.6
18

(7.5)

(For DIN rail


(Pitch)

mounting)
75 15.5 P = 10.5 (17.8)

(11.8)
Power connector
Shipped together with the manifold

D side U side
(L5) L1 Manual override∗1

DIN rail holding screw


(For DIN rail mounting)
( Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
(DIN rail) (Light/surge voltage suppressor) : Grey (For metal seal)
2(B) port side: Yellow

(8)
(5.5)

(35)

92.6
83
80.1

60.5
(40.9)
4.6

4.6
1.7
)
(4.9)
C6: 3.6
N7: 7.4
(Straight type: 12)

4 x M4 Mounting hole
(
(13.2)

L2 1.5 (Fitting for the type with P/E ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10S8V2-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13
L1 132.3 142.8 153.3 163.8 174.3 184.8 195.3 205.8 216.3 226.8 237.3 247.8
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5
L3 160.5 173 185.5 198 198 210.5 223 235.5 248 260.5 260.5 273
L4 150 162.5 175 187.5 187.5 200 212.5 225 237.5 250 250 262.5
L5 14 15 16 17 12 13 14 15 16 17 11.5 12.5

n: Stations 14 15 16 17 18 19 20 21 22 23 24
L1 258.3 268.8 279.3 289.8 300.3 310.8 321.3 331.8 342.3 352.8 363.3
L2 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 285.5 298 310.5 323 335.5 335.5 348 360.5 373 385.5 398
L4 275 287.5 300 312.5 325 325 337.5 350 362.5 375 387.5
L5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5
172
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY5000 Series Connector Connecting Base EX180

U C4, N3
SS5Y5-10S8- Stations D - C6, N7 (D)
B C8, N9

Communication connector
Shipped together with the manifold
One-touch fitting
[1(P), 3/5(E) port] One-touch fitting
Applicable tubing O.D.: Ø 10, Ø 3/8" [4(A), 2(B) port]
Applicable tubing O.D.: Ø 4, Ø 5/32"
(Station 1) (Station n) : Ø 6, Ø 1/4"
SI unit
: Ø 8, Ø 5/16"

Ground terminal
(Straight type: 55.2)

M3

14.1

73.2
(65.4)

56.6
12.4

8.7
33.4

29.1

(7.5)

(For DIN rail


(Pitch) (20.5)

mounting)
(11.8)
76.8 18 P = 16
Power connector
Shipped together with the manifold

D side U side
Manual override∗1
(L5) L1
DIN rail holding screw ( Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting)
4(A) port side: Blue (For rubber seal)
(Light/surge voltage suppressor) : Grey (For metal seal)
(DIN rail) 2(B) port side: Yellow

(8)
(5.5)
(Straight type: 92.1)

(35)

97.5

113.4
93.3
100.9

81.2
(61.7)
5.5

10.9
4.7
(5.9)

(Fitting for the type with P/E ports


(8.3)

on the U and/or D sides)


62.8 L2 1.5 4 x M5 Mounting hole

(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10S8V2-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13
L1 149.3 165.3 181.3 197.3 213.3 229.3 245.3 261.3 277.3 293.3 309.3 325.3
L2 80 96 112 128 144 160 176 192 208 224 240 256
L3 173 198 210.5 223 248 260.5 273 285.5 310.5 323 335.5 360.5
L4 162.5 187.5 200 212.5 237.5 250 262.5 275 300 312.5 325 350
L5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5

n: Stations 14 15 16 17 18 19 20 21 22 23 24
L1 341.3 357.3 373.3 389.3 405.3 421.3 437.3 453.3 469.3 485.3 501.3
L2 272 288 304 320 336 352 368 384 400 416 432
L3 373 385.5 398 423 435.5 448 460.5 485.5 498 510.5 535.5
L4 362.5 375 387.5 412.5 425 437.5 450 475 487.5 500 525
L5 16 14 12.5 17 15 13.5 11.5 16 14.5 12.5 17
173
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY7000 Series Connector Connecting Base EX180

C6, N7
U
SS5Y7-10S8- Stations D - C8, N9
C10, N11 (D)
B C12

One-touch fitting
Communication connector [1(P), 3/5(E) port]
Shipped together with the manifold Applicable tubing O.D.: Ø 12, Ø 1/2"

(Station 1) (Station n)
SI unit

2
Ground terminal
(Straight type: 55.2)

M3

82.7
(65.4)

56.6
14.2

11.1
8.7
35.2

31.6
(Pitch) 21.7

(10)

(For DIN rail


81.8 20.5 P = 19

mounting)
One-touch fitting

(14.3)
[4(A), 2(B) port]
Power connector Applicable tubing O.D.: Ø 6, Ø 1/4"
Shipped together with the manifold : Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
: Ø 12

D side U side
Manual override∗1
(L5) L1
DIN rail holding screw
( Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
(DIN rail) : Grey (For metal seal)
(Light/surge voltage suppressor)
2(B) port side: Yellow

(8)
(5.5)
(Straight type: 92.1)

(35)
93.3

128.8
115
116.3

96.7
(77.1)
5.5

8.8

(Fitting for the type with P/E ports


(6)

3.9
(9.3)

on the U and/or D sides)


(17.9)

(A, B port: Ø 12)


63 L2 1.5 4 x M5 Mounting hole

(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10S8V2-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.

n: Stations 2 3 4 5 6 7 8 9 10 11 12 13
L1 163.5 182.5 201.5 220.5 239.5 258.5 277.5 296.5 315.5 334.5 353.5 372.5
L2 94 113 132 151 170 189 208 227 246 265 284 303
L3 198 210.5 235.5 248 273 285.5 310.5 323 348 360.5 385.5 398
L4 187.5 200 225 237.5 262.5 275 300 312.5 337.5 350 375 387.5
L5 17.5 14 17 14 17 13.5 16.5 13.5 16.5 13 16 13

n: Stations 14 15 16 17 18 19 20 21 22 23 24
L1 391.5 410.5 429.5 448.5 467.5 486.5 505.5 524.5 543.5 562.5 581.5
L2 322 341 360 379 398 417 436 455 474 493 512
L3 423 435.5 460.5 473 498 510.5 535.5 548 573 598 610.5
L4 412.5 425 450 462.5 487.5 500 525 537.5 562.5 587.5 600
L5 16 12.5 15.5 12.5 15.5 12 15 12 15 18 14.5
174
Plug-in Connector Connecting Base
EX180
Type 12
Top Ported
SY3000/5000/7000 Series
How to Order Manifolds

SS5Y 3 12S8 Q 05 U
Refer to pages 182 to 184 for the
dimensions of Type 12/Top-ported type. q w e r t y u i
q Series w SI unit t Valve stations
3 SY3000 0 Without SI unit In the case of the 32-output SI unit
5 SY5000 Q DeviceNet™ Symbol Stations Note
7 SY7000 V CC-Link 02 2 stations
Double wiring∗1


∗ Only the connector block assembly is
e SI unit output polarity, Number of outputs mounted for models without an SI unit. 16 16 stations
02 2 stations
32 outputs 16 outputs Specified layout∗2
r Communication connector


Without SI unit — (Up to 32 solenoids available)
Positive common (NPN) 2 3 — T-branch type 24 24 stations
Negative common (PNP) 4 5 A Straight type In the case of the 16-output SI unit
∗ When “V” (CC-Link) is selected for the SI unit, only ∗ The communication connector and power connector Symbol Stations Note
symbol “2” or “4” (32 outputs) can be selected. are shipped together with the manifold. The power 02 2 stations
∗ Ensure a match with the common specification of Double wiring∗1


connector is only available for the straight type.
the valves to be used. ∗ When not selecting an SI unit, the symbol will be 08 8 stations
“—.” 02 2 stations
Specified layout∗2
y P, E port entry, SUP/EXH block assembly


(Up to 16 solenoids available)
P, E port entry Internal pilot Internal pilot, Built-in silencer External pilot 16 16 stations
U side (2 to 10 stations) U C∗1 G ∗1 Double wiring: 2-position single, double,
D side (2 to 10 stations) D E∗1 H 3-position, and 4-position valves can be
Both sides (2 to 24 stations) B — J used on all manifold stations.
Use of a 2-position single solenoid will result
∗1 For SUP/EXH block assembly specifications, built-in silencer types will have P port entry stipulated.
∗ For built-in silencer type, P and E ports are available on U and D sides. 3/5(E) port is plugged. The in an unused control signal. If this is not
silencer exhaust port is located on the opposite side of P, E port entry. (Example: When the P, E desired, order with a specified layout.
port entry is D side, the silencer exhaust port is U side.) ∗2 Specified layout: Indicate the wiring
∗ When the built-in silencer type is used, keep the exhaust port from coming in direct contact with specifications on the manifold specification
water or other liquids. sheet. (Note that 2-position double, 3-position,
and 4-position valves cannot be used where
How to Order Manifold Assembly single wiring has been specified.)
∗ This also includes the number of the blanking
plate assembly.
Example (SS5Y3-12S8-) ∗ For the product without the SI unit (S80),
note the maximum number of solenoids of
2-position double (24 VDC) 3-position closed centre (24 VDC) the SI unit that will be mounted. If the layout
SY3230-5U1-C6 (1 set) SY3330-5U1-C6 (1 set) is specified, indicate it on the manifold
specification sheet.

u P, E port size (One-touch fittings)


2-position single (24 VDC)
SY3130-5U1-C6 (3 sets)
Symbol SY3000 SY5000 SY7000
ide — Ø8 Ø 10 Ø 12
Us
N Ø 5/16" Ø 3/8" Ø 1/2"
s
n
tio
ta
S

∗ For N, sizes are in inches.


2 3
e
1
id
Manifold base (5 stations)
SS5Y3-12S8V2-05D
Ds
i Mounting
— Direct mounting
SS5Y3-12S8V2-05D ···· 1 set (Type 10 5-station manifold base part no.) D DIN rail mounting (With DIN rail)
∗SY3130-5U1-C6 ··········· 3 sets (2-position single part no.) D0 DIN rail mounting (Without DIN rail)
∗SY3230-5U1-C6 ··········· 1 set (2-position double part no.) D3 For 3 stations Specify a longer
∗SY3330-5U1-C6 ··········· 1 set (3-position closed centre part no.)
···

···

rail than the ∗ Refer to page 3 1 9 for the fixation


The asterisk denotes the symbol for the assembly. D24 For 24 stations standard length. of DIN rail mounting type manifold.
Prefix it to the part numbers of the valve, etc.
• For the valve arrangement, the valve closest to the D side is considered the 1st station. For details on the EX18 0 Integrated Type (For Output) Serial Transmission
• Under the manifold part number, state the valves to be mounted in order System, refer to the Web Catalogue and the Operation Manual. For the part
starting with the 1 st station as shown in the figure above. If the arrangement numbers of the SI units to be mounted, refer to page 219. Please download
becomes too complicated, specify the details on a manifold specification sheet. the Operation Manual via the SMC website: https://www.smc.eu

175
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Refer to page 17 for valve
How to Order Valves (With mounting screw) specifications.

SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported

q Series y Pilot valve option !1 A, B port size


3 SY3000 — Standard (0.7 MPa) Thread piping
5 SY5000 B Quick response type (0.7 MPa) Symbol Port size Applicable series
7 SY7000 K∗1 High-pressure type (1.0 MPa) M5 M5 x 0.8 SY3000
∗1 Only the metal seal type is available for the 01 1/8 SY5000
high-pressure type. 02 1/4 SY7000
w Type of actuation One-touch fitting (Metric)
1
2-position
Single u Coil type Symbol A, B port SY3000 SY5000 SY7000
2 Double — Standard C2 Ø2  — —
3 Closed centre T With power-saving circuit (Continuous duty type) C3 Ø 3.2  — —
4 3-position Exhaust centre ∗ Be sure to select the power-saving circuit C4 Ø4   —
5 Pressure centre type when the valve is to be continuously C6 Ø6   
A∗1 N.C./N.C. energised for long periods of time. C8 Ø8 —  
4-position ∗ Be careful of the energising time when the
B∗1 dual 3-port
N.O./N.O.
power-saving circuit is selected. Refer to
C10 Ø 10 — — 
C∗1 N.C./N.O. page 316 for details.
C12 Ø 12 — — 
∗1 Only the rubber seal type is available for the One-touch fitting (Inch)
4-position dual 3-port valve.
i Rated voltage Symbol A, B port SY3000 SY5000 SY7000
5 24 VDC N1 Ø 1/8"  — —
N3 Ø 5/32"   —
e Seal type N7 Ø 1/4"   
0 Rubber seal o Light/surge voltage suppressor N9
N11
Ø 5/16"
Ø 3/8"






1 Metal seal and common specification
Surge voltage Common
Symbol With light
suppressor specification

r Pilot type R —
Non-polar
!2 Thread type
U  — Rc
— Internal pilot
S — Positive
 F G
R External pilot
Z  common N NPT
NS — Negative T NPTF
NZ  common ∗ Only — is available for M5.
t Back pressure check valve ∗ Select “R,” “U,” “S,” or “Z” for the valve when
(Built-in valve type) the SI unit output polarity is positive common.
Select “R,” “U,” “NS,” or “NZ” for the valve

H
None
Built-in
when the SI unit output polarity is negative
common.
!3 Type of mounting screw
∗ Only the rubber seal type is available. A ∗ Only “Z” and “NZ” are available with a — Round head combination screw
manifold installed type is available if a back power-saving circuit. B Hexagon socket head cap screw
pressure check valve with a metal seal is K Round head combination screw (Drop prevention type)
required. Refer to page 236 for ordering
examples. However, it is not recommended !0 Manual override H Hexagon socket head cap screw (Drop prevention type)
∗ For “K” and “H,” the valve body cover has a
to use the built-in valve type and the manifold —: D: drop prevention construction to stop the
installed type at the same time because it will Non-locking Push-turn mounting screws from falling out when the
reduce the flow. push type locking slotted valve is removed for maintenance, etc.
∗ The built-in valve type back pressure check type ∗ When ordering a valve individually, the
valve is not available for the 3-position type base gasket is not included.
or the SY7000. Since the base gasket is attached to the
manifold, please order the base gasket
separately if it is needed for maintenance.
∗ “B” and “H” cannot be selected for the
E: F: individual SUP/EXH spacer assembly or
Push-turn Slide locking interface regulator.
locking lever type
type

∗ Refer to page 36 for the safety slide locking


manual override.

Protective class
class # (Mark: )
176
SY3000/5000/7000 Series
Common Dimensions
Plug-in Type 10/Side Ported

SY3000 Series Connector Connecting Base External Pilot, Silencer, Elbow Fittings, Slide Locking Manual Override

U
SS5Y3-10- Stations D (S, R)- LB (Station 1)---(Station n)
B

manual override)
(Slide locking
1 P
(65.4)

68.8
63.1
56.6
(43.2)

3/5 E

)
)
L6 : 32.4
LN7 : 34.9
L6 : 43.4
LN7 : 45.9
(Pitch)
15.5 P= 10.5 (17.8)

(
(
D side U side
One-touch fitting 7.4 85.5
[PE: Pilot EXH port] (For 5 stations)
[X: External pilot port]
(7.4) (11.6) (73.2)
Applicable tube O.D.: Ø 4, Ø 5/32"
(Fitting for the type with P/E
ports on the U and/or D sides)
5.3

PE PE

LOCK
X X
3/5E B A B A B A B A B A 3/5E
14 A 14 A 14 A 14 A 14 A
(127.8)

40.9
58.5

FREE
1P 1P
12 B 12 B 12 B 12 B 12 B
11.6

6.9
1.7

17.3
27.6
35.2

2(B) port (Fitting for the type with P/E


ports on the U and/or D sides)
1(P) port 4(A) port 70.6
3/5(E) port External pilot for straight piping
One-touch fitting P, E port entry: D
[1(P), 3/5(E) port]
7.4 85.5
Applicable tube O.D.: Ø 8, Ø 5/16"
(For 5 stations)
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.": Ø 4, Ø 5/32" PE LOCK
X
: Ø 6, Ø 1/4" B A B A B
14 A 14 A 14
FREE
(42.8)
(37.5)

∗: These figures show the “SS5Y3-10F2-05DR-L6”. 1P


12 B 12 B

One-touch fitting 78.6


[PE: Pilot EXH port] 82.3
[X: External pilot port]
Applicable tubing O.D.: Ø 4, Ø 5/32"

Built-in silencer Downward (Type B)


<Internal pilot>
P, E port entry: D [P, E port entry] [A, B port entry]
Silencer (Exhaust port)
(Built-in silencer specification)
LOCK

LOCK
LOCK

FREE

FREE

B A B A B
14 A 14 A 14

(11.2)
FREE

4(A) port
12 B 12 B
3/5(E) port

2(B) port

1(P) port
Plug
(0.2)
3/5(E) port (7.2) (15)

177
Common Dimensions SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

SY5000 Series Connector Connecting Base External Pilot, Silencer, Elbow Fittings, Slide Locking Manual Override

U
SS5Y5-10- Stations D (S, R)- LB
B
(Station 1)----------- (Station n)

manual override)
(Slide locking
78.9
1 P
66.1
(59.8)

(54.3)
(39.3)
(38.8)

3/5 E

4 A4 A4 A4 A4 A

∗: These figures show the “SS5Y5-10F2-05DR-L8”.


(Pitch)
18 P = 16 (20.5)

One-touch fitting D side U side


[PE: Pilot EXH port] 118.2
[X: External pilot port] (For 5 stations)
(12) (65.4)
Applicable tube O.D.: Ø 4, Ø 5/32"
(Fitting for the type with P/E
ports on the U and/or D sides)

LOCK
PE PE
3/5 B A B A B A B A B A 3/5
26.9

14 A 14 A 14 A 14 A 14 A
113.4

E E

FREE
X X
1 1
(159.5)

61.7
52.8

P P
12 B 12 B 12 B 12 B 12 B
17.9

4.7
12.6
28.6
36.9

(Fitting for the type with P/E


2(B) port ports on the U and/or D sides)
1(P) port External pilot for straight piping
4(A) port One-touch fitting
3/5(E) port [4(A), 2(B) port] (118.2) P, E port entry: D
One-touch fitting Applicable tube O.D.: Ø 4, Ø 5/32"
(For 5 stations)
[1(P), 3/5(E) port] : Ø 6, Ø 1/4" (20°)
Applicable tube O.D.: Ø 10, Ø 3/8" : Ø 8, Ø 5/16"
Built-in silencer
P, E port entry: D PE

LOCK
3/5 BA BA
Silencer (Exhaust port) 14 A 14 A

(Built-in silencer specification) E


FREE

X
1
(59.8)

P
(31.7)

12 B 12 B 12 B
LOCK

BA BA
14 A 14 A
FREE

One-touch fitting 70.8


[PE: Pilot EXH port] 74.5
12 B 12 B 12 B [X: External pilot port]
Applicable tube O.D.: Ø 4, Ø 5/32"

Plug Valve/SY3000 Series (Mixed Mounting)


3/5(E) port
Downward (Type B) Upward (Type L)
Downward (Type B)
[P, E port entry] [A, B port entry]
LOCK

LOCK

One-touch fitting
LOCK

LOCK

[4(A), 2(B) port]


FREE

FREE

Applicable tubing O.D.: Ø 4, Ø 5/32"


( B6 : 10.7
BN7 : 13.2 ) : Ø 6, Ø 1/4"
FREE

FREE

6.5

16.9

4(A) port

2(B) port ( L6 : 32.9


LN7 : 35.4 )
( B6 : 9.7
BN7 : 7.2 )
(14) (7)
(11.1) (3.9) ( L6 : 53.3
LN7 : 55.8 )
178
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

SY7000 Series Connector Connecting Base External Pilot, Silencer, Elbow Fittings, Slide Locking Manual Override

U
SS5Y7-10- Stations D (S, R)- LB External pilot for straight piping
B P, E port entry: D
(138.1)
(For 5 stations)
(20°)
(Station 1) (Station n)

(Slide locking manual override)


PE

LOCK
3/5E B A B A

(For Ø 10, Ø 3/8")


14 A 14 A

85.8
(For Ø 10, Ø 3/8")

1 P

(For Ø 12)
69.7

(For Ø 10, Ø 3/8")


(53.1)

(53.1)

(58)

FREE
(For Ø 12)
(For Ø 10, Ø 3/8")

(37.5)
(32.6)

(32.6)
3/5 E

1P

(74.2)
(23.5)
12 B 12 B

20.5 (Pitch) (21.7)


P = 19
One-touch fitting One-touch fitting 77.7
[PE: Pilot EXH port] [PE: Pilot EXH port] 82.7
[X: External pilot port] [X: External pilot port]
D side Applicable tube O.D.: Ø 6, Ø 1/4" U side
Applicable tube O.D.: Ø 6, Ø 1/4"
138.1
(For 5 stations) (10.9) (69.5)

(Fitting for the type with P/E


ports on the U and/or D sides)

PE PE

LOCK
3/5E B A B A B A B A B A 3/5E
14 A 14 A 14 A 14 A 14 A
49.4
128.8

FREE
(175.6)

1P 1P
(77.1)

X X
45.4

12 B 12 B 12 B 12 B 12 B
15.6
3.9

34.6
37.6
16.6

(Fitting for the type with P/E


1(P) port ports on the U and/or D sides)
3/5(E) port One-touch fitting
One-touch fitting 4(A) port [4(A), 2(B) port]
Applicable tube O.D.: Ø 12
[1(P), 3/5(E) port] 2(B) port
Applicable tube O.D.: Ø 12, Ø 1/2"
One-touch fitting ∗: These figures show the “SS5Y7-10F2-05DR-LM”.
[4(A), 2(B) port]
Applicable tube O.D.: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
Built-in silencer
P, E port entry: D Downward (Type B)
[P, E port entry] [A, B port entry]
Silencer (Exhaust port)
(Built-in silencer specification)
LOCK

LOCK
FREE

FREE
LOCK

B A B A
14 A 14 A
FREE

12 B 12 B

3/5(E) port 4(A) port


2(B) port
1(P) port
(7.3) (13.7) ( Ø 10: 15.3
Ø 12: 10.4 ) ( Ø 10: 5.2
Ø 12: 10.1 )
179
Common Dimensions SY3000/5000/7000 Series
Plug-in Type 11/Bottom Ported

SY5000 Series Connector Connecting Base All Wirings

U
SS5Y5-11- Stations D
B External pilot
120.5 (118.2) P, E port entry: D
(For 5 stations) (For 5 stations)
(20°)
(Pitch)
18 P = 16 (20.5)
4.7

LOCK
PE
31.8

3/5 B A B A

39.7
14 A 14 A
3/5 E 3/5 E
2 B2 B2 B2 B2 B E

FREE
X
18

15 1

(59.8)
1 P 1 P P
4 A4 A4 A4 A4 A

(31.7)
12 B 12 B 12 B

Cut dimensions for panel mounting


Refer to panel cut dimensions
for details.
One-touch fitting 70.8
[PE: Pilot EXH port] 74.5
One-touch fitting One-touch fitting [X: External pilot port]
Applicable tube O.D.: Ø 4, Ø 5/32"
[1(P), 3/5(E) port] [4(A), 2(B) port]
Applicable tube O.D.: Ø 10, Ø 3/8" Applicable tube O.D.: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4" Built-in silencer
: Ø 8, Ø 5/16" Silencer (Exhaust port) P, E port entry: D
(Station 1) ---------- (Station n)
(Built-in silencer specification)
manual override)
(Slide locking
78.9
73.2

LOCK
BA BA
14 A 14 A
8.7
4.7

FREE
(9.5)
(12.9)

12 B 12 B 12 B
(Fitting for the type with P/E
ports on the U and/or D sides)

Plug
D side U side
L2 1.5 Manual override

(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
: Grey (For metal seal)
2(B) port side : Yellow

4 x M5 mounting hole
LOCK

BA BA BA BA B A
14 A 14 A 14 A 14 A 14 A
97.5

FREE
5.5

12 B 12 B 12 B 12 B 12 B
10.9

∗ These figures show the “SS5Y5-11F2-05D-C8.”


Panel fitting dimensions ∗ Refer to the pages below for L2 dimensions and other dimensions that are
not specified in each wiring specification.
D-sub connector <IP40> : p. 47
7

D-sub connector <IP67> : p. 50


Flat ribbon cable : p. 53
Terminal block box (Spring type) : p. 64
60

Terminal block box : p. 73


97.5

Lead wire : p. 83
Circular connector : p. 93
EX500 (128 points) : p. 103
EX500 (64 points) : p. 109
EX600 : pp. 120, 121
L2 EX250 : p. 138
4 x M5 Mounting hole EX260 : p. 149
4 x Ø 5.5 EX126 : p. 157
EX120 : p. 165
180
SY3000/5000/7000 Series
Plug-in Type 11/Bottom Ported

SY7000 Series Connector Connecting Base All Wirings

U
SS5Y7-11- Stations D External pilot
B
P, E port entry: D (138.1)
(Pitch) (For 5 stations)
40.1 (20°)
39.5 20.5 P = 19 (21.7)
3.9
39.9

48.7
PE

LOCK
3/5 E 3/5 E
3/5E B A B A
2 B2 B2 B2 B2 B 14 A 14 A
21

19.5

FREE
4 A4 A4 A4 A4 A

1 P 1 P
1P

(74.2)
Fitting dimensions for panel mounting 12 B 12 B

(23.5)
Refer to panel fitting dimensions
for details. X

One-touch fitting One-touch fitting One-touch fitting 77.7


[1(P), 3/5(E) port] [4(A), 2(B) port] [PE: Pilot EXH port]
82.7
Applicable tube O.D.: Ø 12, Ø 1/2" Applicable tube O.D.: Ø 6, Ø 1/4" [X: External pilot port]
: Ø 8, Ø 5/16" Applicable tube O.D.: Ø 6, Ø 1/4"
: Ø 10, Ø 3/8"
(Station 1) (Station n) : Ø 12
Built-in silencer
(Slide locking manual override)

P, E port entry: D
Silencer (Exhaust port)
2

(Built-in silencer specification)


85.8
82.7
56.6

LOCK
8.7

B A B A
14 A 14 A

FREE
9.1
(12)
(14.5)

(23.9)

(A, B port: Ø 12) (Fitting for the type with P/E Plug
12 B 12 B
ports on the U and/or D sides)

D side L2 1.5 U side


Manual override

( Push-turn locking slotted type:


Press, then rotate it. )
4(A) port side:
Blue (For rubber seal)
Grey (For metal seal)
2(B) port side : Yellow
LOCK

B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
115

FREE

4 x M5 mounting hole
12 B 12 B 12 B 12 B 12 B
5.5
8.8

Panel fitting dimensions ∗ These figures show the “SS5Y7-11F2-05D-C10.”


∗ Refer to the pages below for L2 dimensions and other
dimensions that are not specified in each wiring specification.
16

D-sub connector <IP40> : p. 48


D-sub connector <IP67> : p. 51
Flat ribbon cable : p. 54
Terminal block box (Spring type) : p. 65
60

Terminal block box : p. 74


115

Lead wire : p. 84
Circular connector : p. 94
EX500 (128 points) : p. 104
EX500 (64 points) : p. 110
EX600 : pp. 122, 123
EX250 : p. 139
4 x M5 EX260 : p. 150
L2 Mounting hole EX126 : p. 158
4 x Ø 5.5 EX120 : p. 166
181
Common Dimensions SY3000/5000/7000 Series
Plug-in Type 12/Top Ported

SY3000 Series Connector Connecting Base All Wirings

U
SS5Y3-12- Stations D (R)
B
(Station 1)---(Station n)

)C6: 77.3
N7: 81.1
1 P 1 P
(73.8)

3/5 E 2 B2 B2 B2 B2 B 3/5 E

(
4 A4 A4 A4 A4 A

D side U side
89.3
(For 5 stations) Light/surge voltage suppressor

One-touch fitting (External pilot) (Pitch) Manual override


[PE: Pilot EXH port] 16 P = 10.5
[X: External pilot port]
7.4 (15.3)
(
Push-turn locking slotted type:
Press, then rotate it. )
Applicable tube O.D.: Ø 4, Ø 5/32" 4(A) port side : Blue (For rubber seal)
: Grey (For metal seal) (73.2)
2(B) port side : Yellow
5.3

PE PE

LOCK
X X
3/5E B A B A B A B A B A 3/5E
92.6

4A 4A 4A 4A 4A
15

11

60.5
58.5

FREE
40.9
1P 1P
31.8

30.2

2B 2B 2B 2B 2B
1.7

One-touch fitting
(A/B port, side ported)

[1(P), 3/5(E) port]


(Fitting for the type with P/E
Applicable tube O.D.: Ø 8, Ø 5/16"
)

ports on the U and/or D sides)


C6: 3.6
N7: 7.4

M5 x 0.8
[4(A), 2(B) port] One-touch fitting
(

[4(A), 2(B) port]


Applicable tube O.D.: Ø 2
: Ø 3.2, Ø 1/8"
: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"

∗ These figures show the “SS5Y3-12F2-05D.”


∗ For the built-in silencer type, a silencer is mounted on the opposite side of U or D side with P or E
port. Refer to page 177 for dimensions of the silencer.
∗ Refer to the pages below for dimensions that are not specified in each wiring specification.
D-sub connector <IP40> : p. 46
D-sub connector <IP67> : p. 49
Flat ribbon cable : p. 52
Terminal block box (Spring type) : p. 63
Terminal block box : p. 72
Lead wire : p. 82
Circular connector : p. 92
EX500 (128 points) : p. 102
EX500 (64 points) : p. 108
EX600 : pp. 118, 119
EX250 : p. 137
EX260 : p. 148
EX126 : p. 156
EX120 : p. 164

182
SY3000/5000/7000 Series
Plug-in Type 12/Top Ported

SY5000 Series Connector Connecting Base All Wirings

U
SS5Y5-12- Stations D (R)
B
(Station 1)----------- (Station n)

(91.3)
76.9

1 P 1 P
(69.7)

2 B2 B2 B2 B2 B

3/5 E 3/5 E

4 A4 A4 A4 A4 A

D side U side
Light/surge voltage suppressor
123.6
(For 5 stations)

(Pitch) Manual override


(17.4) 78.9
5.4
21.1 P = 16
(5.4)
(
Push-turn locking slotted type:
Press, then rotate it. ) (Slide locking
manual override)
One-touch fitting (External pilot) 4(A) port side : Blue (For rubber seal)
[PE: Pilot EXH port] : Grey (For metal seal) (65.4)
[X: External pilot port] 2(B) port side : Yellow
Applicable tube O.D.: Ø 4, Ø 5/32"
26.5

PE PE

LOCK
BA BA BA BA B A
3/5 3/5
26.9

4A 4A 4A 4A 4A
113.4
116.7

E E

FREE
X X
1 1
81.2

61.7
01 : 16.2
C : 14.5
52.8

P P
47.3
39.5

2B 2B 2B 2B 2B

One-touch fitting (Fitting for the type with P/E


4.7

2.7

[1(P), 3/5(E) port] ports on the U and/or D sides)


Applicable tube O.D.: Ø 10, Ø 3/8" 1/8
[4(A), 2(B) port] One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"

∗ These figures show the “SS5Y5-12F2-05D.”


∗ For the built-in silencer type, a silencer is mounted on the opposite side of U or D side with P or E port.
Refer to page 178 for dimensions of the silencer.
∗ Refer to the pages below for dimensions that are not specified in each wiring specification.
D-sub connector <IP40> : p. 47
D-sub connector <IP67> : p. 50
Flat ribbon cable : p. 53
Terminal block box (Spring type) : p. 64
Terminal block box : p. 73
Lead wire : p. 83
Circular connector : p. 93
EX500 (128 points) : p. 103
EX500 (64 points) : p. 109
EX600 : pp. 120, 121
EX250 : p. 138
EX260 : p. 149
EX126 : p. 157
EX120 : p. 165

183
Common Dimensions SY3000/5000/7000 Series
Plug-in Type 12/Top Ported

SY7000 Series Connector Connecting Base All Wirings

U
SS5Y7-12- Stations D (R)
B

(Station 1) (Station n)

(A, B port: Ø 12)


(Fitting for the type with P/E
ports on the U and/or D sides)

(112.1)
(100.3)
88.8

1 P 1 P
(75.1)

2 B2 B2 B2 B2 B

3/5 E 3/5 E

8.7
4 A4 A4 A4 A4 A

(For DIN rail


(10)

mounting)
(14.3)
One-touch fitting
(External pilot) D side U side
[PE: Pilot EXH port] (Light/surge voltage suppressor)
[X: External pilot port]
144.3 Manual override
Applicable tube O.D.: Ø 6, Ø 1/4"
(Pitch)
26.1 P = 19
(For 5 stations)
(17.1)
(
Push-turn locking slotted type:
Press, then rotate it. ) 85.8
(Slide locking manual override)
4(A) port side: Blue (For rubber seal)
6.2 (6.2) : Grey (For metal seal) (69.5)
2(B) port side: Yellow

PE PE

LOCK
3/5E B A B A B A B A B A 3/5E
4A 4A 4A 4A 4A
(49.4)
21

128.8
133.2

FREE
22.6
96.7

1P 1P
(77.1)

X X
59.9
(45.5)

46.4

2B 2B 2B 2B 2B
2.4

1/4 4 x M5 mounting hole


3.9

[4(A), 2(B) port] One-touch fitting


One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: Ø 6, Ø 1/4"
Applicable tube O.D.: Ø 12, Ø 1/2" : Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
: Ø 12

∗ These figures show the “SS5Y7-12F2-05D.”


∗ For the built-in silencer type, a silencer is mounted on the opposite side of U or D side with P or E port.
Refer to page 179 for dimensions of the silencer.
∗ Refer to the pages below for dimensions that are not specified in each wiring specification.
D-sub connector <IP40> : p. 48
D-sub connector <IP67> : p. 51
Flat ribbon cable : p. 54
Terminal block box (Spring type) : p. 65
Terminal block box : p. 74
Lead wire : p. 84
Circular connector : p. 94
EX500 (128 points) : p. 104
EX500 (64 points) : p. 110
EX600 : pp. 122, 123
EX250 : p. 139
EX260 : p. 150
EX126 : p. 158
EX120 : p. 166

184
Plug-in Connector Connecting Base: Plug-in Manifold Mixed Mounting Type
D-sub Connector (IP40/67) Flat Ribbon Cable Terminal Block Box/Spring Type (IP67)
Type 10 Terminal Block Box (IP67) Lead Wire (IP67) Circular Connector (IP67) EX500 (IP67)
Side Ported EX600 (IP67) EX245 (IP65) EX250 (IP67) EX260 (IP67) EX126 (IP67) EX120 EX180

Type 11
Bottom Ported
SY3000/5000 Series ®

The SY3000 can be mounted onto the ∗ Refer to the connector type.
SY5000 size manifold. How to Order Manifolds
Refer to page 174 for the
dimensions of Type 11/
Bottom-ported type.
SS5Y5 M 10 F 1 05 U C 8 6
Mixed Mounting Type
It is possible to mount the SY3000 size valves on all stations.
q w e r t y u i o !0
In this case, there is no need to fill in part i in the order code.
However, the manifold block width should be 12.5 mm.

q Type r Valve stations y SUP/EXH block assembly


10 Side ported Symbol Stations Note — Internal pilot
11 Bottom ported 02 2 stations Some connectors have a limitation S Internal pilot, Built-in silencer
on the number of stations. Refer R External pilot

to the pages shown in the table


∗ 3/5(E) port is plugged for the built-in silencer
w Connector type 24 24 stations “Connector type” for details.
type.
Symbol Type Page ∗ Refer to page 115 for the EX600 and u on
F
FW
D-sub connector
(25 pins)
IP40
IP67
t P, E port entry page 127 for the EX250.

U U side (2 to 10 stations)
P 26 pins 43
D D side (2 to 10 stations)
PG Flat ribbon cable 20 pins
B Both sides (2 to 24 stations)
PH 10 pins
∗ Refer to page 115 for the EX600 and u on
TC Terminal block box (Spring type) 61
page 127 for the EX250.
T Terminal block box 69
L1 34 cores
L2 Lead wire 17 cores 79 u Fitting type: One-touch fitting
L3 9 cores Symbol A, B port
M Circular connector 89 C Straight
EX500 Gateway L Metric size Upward∗2
Elbow
Decentralised B Downward∗2
S System 2
99
N Straight
(128 points) LN Inch size Upward∗2
Elbow
EX500 Gateway BN Downward∗2
Decentralised CM∗1 Straight
S 105 Mixed sizes
System LM∗1 Elbow (Including upward and downward piping)∗2
Serial (64 points)
transmission ∗1 Select CM or LM if mixed port sizes are to be used for each series.
S6 EX600 115 (For example, if mixed sizes, such as C6 and C8, are to be used for
SA EX245 127 the SY5000 series) In such cases, indicate the sizes on the manifold
S EX250 133 specification sheet.
The direction of P, E port fittings is the same as for the A, B port. If
S EX260 141
selecting “LM,” indicate it on the manifold specification sheet for the P,
S4∗1 EX126 153 E port fitting direction.
S3∗1 EX120 161 ∗2 To avoid interference with the body or piping, select a downward
S8 EX180 169 elbow port when mounting the optional spacer assembly (pages 228
∗1 EX126, EX120 are not yet UL-compliant. to 230). Elbow fittings are not available for Type 11 (Bottom ported).
∗ Refer to the pages shown in the table above for details. ∗ Elbow fittings: Ø 2, Ø 3.2, and Ø 1.8" are not available for the SY3000
series. Ø 2, Ø 3.2, Ø 1.8", and Ø 5/32" are not available for the SY5000
e series.

• With Lead wire


Lead wire length
1 0.6 m
2 1.5 m
3 3m

• With D-sub connector (IP40/67) and


Flat ribbon cable
Connector entry direction
1 Upward
2 Lateral

∗ It is not necessary to select the items above for


the valve with terminal block box or with circular
connector or the serial transmission type.
185
Plug-in Connector Connecting Base SY3000/5000 Series

i SY5000: A, B port size !0 Mounting


(Metric/One-touch fitting) (Inch/One-touch fitting) — Direct mounting
Symbol Port size Symbol Port size D DIN rail mounting (With DIN rail)
4 Ø4 3 Ø 5/32" D0 DIN rail mounting (Without DIN rail)
6 Ø6 7 Ø 1/4" D3 For 3 stations Specify a length longer than that of the standard rail.


8 Ø8 9 Ø 5/16" [The SY5000 valve is now at a mountable length
— For all stations of SY3000 — For all stations of SY3000 D24 For 24 stations (manifold block length of 16 mm).]
∗ No symbol needs to be specified when fitting type “CM” or “LM” is ∗ Only direct mounting is available for the type 11 bottom-ported type.
selected. ∗ Refer to page 192 to determine the L3 using “Calculation formula” for
the DIN rail length.
∗ Refer to page 319 for the fixation of DIN rail mounting type manifold.
o SY3000: A, B port size
(Metric/One-touch fitting) (Inch/One-touch fitting)
Symbol Port size Symbol Port size
2 Ø2 1 Ø 1/8"
3 Ø 3.2 3 Ø 5/32"
4 Ø4 7 Ø 1/4"
6 Ø6 9 Ø 5/16"∗1
8 Ø 8∗1
∗1 The valve pitch is the same as that of the SY5000.
∗ No symbol needs to be specified when fitting type “CM” or “LM” is
selected.

How to Order Manifold Assembly

Example (SS5Y5-M10F1-)
2-position double
2-position double SY3200-5U1 (2 sets)
SY5200-5U1 (3 sets) Manifold base (5 stations)
SS5Y5-M10F1-05D-C86

ide
Us
o ns
ati
St
3
2
1
e
D sid

SS5Y5-M10F1-05D-C86 ··· 1 set (Type M10 5-station manifold base part no.)
∗SY5200-5U1 ····················· 3 sets (2-position double part no.)
∗SY3200-5U1 ····················· 2 sets (2-position double part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
• For the valve arrangement, the valve closest to the D side is considered the 1st station.
• Under the manifold part number, state the valves to be mounted in order starting
with the 1st station as shown in the figure above. If the arrangement becomes too
complicated, specify the details on a manifold specification sheet.
∗ When mixing top-ported configurations, select from those listed on page 198.
In such cases, use caution as there is also output on the A and B ports on
the base side.
Protective class
Specify on the manifold specification sheet if plugs are required for the A and
B ports on the base side.
class # (Mark: )
186
SY3000/5000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

q Series y Pilot valve option !0 Manual override


3 SY3000 — Standard (0.7 MPa) —: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
K∗1 High pressure type (1.0 MPa) push type locking
∗1 Only the metal seal type is available for the slotted
type
w Type of actuation
high pressure type.

1 Single
2
2-position
Double u Coil type E: F:
3 Closed centre — Standard
Push-turn Slide locking
4 3-position Exhaust centre T With power saving circuit (Continuous duty type) locking type
5 Pressure centre ∗ Be sure to select the power saving circuit lever
A∗1 N.C./N.C. type if the valve is to be continuously type
4-position energised for long periods of time.
B∗1 dual 3-port
N.O./N.O.
C∗1 N.C./N.O. ∗ Be careful of the energising time when the
power saving circuit is selected. Refer to
∗1 Only the rubber seal type is available for the page 316 for details. ∗ Refer to page 36 for the safety slide locking
4-position dual 3-port valve. manual override.

i Rated voltage
e Seal type 5 24 VDC !1 Type of mounting screw
0 Rubber seal 6 12 VDC
— Round head combination screw
1 Metal seal ∗ Only 24 VDC is available for the serial B Hexagon socket head cap screw
transmission type.
K Round head combination screw (Drop prevention type)
H Hexagon socket head cap screw (Drop prevention type)
r Pilot type o Light/surge voltage suppressor ∗ For “K” and “H,” the valve body cover has a
drop prevention construction to stop the
— Internal pilot and common specification mounting screws from falling out when the
R External pilot
Symbol With light
Surge voltage Common valve is removed for maintenance, etc.
suppressor specification ∗ When ordering a valve individually, the
— — — base gasket is not included.
R — Non-polar Since the base gasket is attached to the
t Back pressure check valve U 
manifold, please order the base gasket
(Built-in valve type) separately if it is needed for maintenance.
S — Positive Refer to page 222 for base gasket and
— None 
Z  common mounting screw part numbers.
H Built-in NS — Negative ∗ “B” and “H” cannot be selected for the
∗ Only the rubber seal type is available. A NZ  common individual SUP/EXH spacer assembly,
manifold installed type is available if a back ∗ “—” is not available for the SI unit manifold. interface regulator, or double check spacer
pressure check valve with a metal seal is ∗ For the non-polar type, be careful of surge assembly with residual pressure release
required. Refer to page 236 for ordering voltage intrusion. valve.
examples. However, it is not recommended Refer to page 317 for details.
to use the built-in valve type and the manifold ∗ Only “Z” and “NZ” types are available with a
installed type at the same time because it will power saving circuit. Select a valve which is
reduce the flow. suited to the SI unit output polarity or SI unit
∗ The built-in valve type back pressure check specification when the SI unit is selected.
valve is not available for the 3-position type. Refer to the pages below for details.
EX500: pp. 101, 107 EX600: p. 117
EX245: p. 127 EX250: p. 136
EX260: p. 144 EX126: p. 155
EX120: p. 163 EX180: p. 171

Protective class
class # (Mark: )
187
188
Plug-in Connector Connecting Base: Plug-in Manifold Mixed Mounting Type
D-sub Connector (IP40/67) Flat Ribbon Cable Terminal Block Box/Spring Type (IP67)
Type 10 Terminal Block Box (IP67) Lead Wire (IP67) Circular Connector (IP67) EX500 (IP67)
Side Ported EX600 (IP67) EX250 (IP67) EX260 (IP67) EX126 (IP67) EX120

Type 11
Bottom Ported
SY5000/7000 Series ®

The SY5000 can be mounted onto the ∗ Refer to the connector type.
SY7000 size manifold. How to Order Manifolds
Refer to page 195 for the
dimensions of Type 11/
Bottom-ported type.
SS5Y7 M 10 F 1 05 U C 10 8
Mixed Mounting Type
It is possible to mount the SY5000 size valves on all stations.
q w e r t y u i o !0
In this case, there is no need to fill in part i in the order code.
However, the manifold block width should be 19 mm.

q Type r Valve stations y SUP/EXH block assembly


10 Side ported Symbol Stations Note — Internal pilot
11 Bottom ported 02 2 stations Some connectors have a limitation S Internal pilot, Built-in silencer
on the number of stations. Refer R External pilot

to the pages shown in the table


∗ 3/5(E) port is plugged for the built-in silencer
w Connector type 24 24 stations “Connector type” for details.
type.
Symbol Type Page ∗ Refer to page 115 for the EX600 and u on
F
FW
D-sub connector
(25 pins)
IP40
IP67
t P, E port entry page 127 for the EX250.

U U side (2 to 10 stations)
P 26 pins 43
D D side (2 to 10 stations)
PG Flat ribbon cable 20 pins
B Both sides (2 to 24 stations)
PH 10 pins
∗ Refer to page 115 for the EX600 and u on
TC Terminal block box (Spring type) 61
page 127 for the EX250.
T Terminal block box 69
L1 34 cores
L2 Lead wire 17 cores 79 u Fitting type: One-touch fitting
L3 9 cores Symbol A, B port
M Circular connector 89 C Straight
EX500 Gateway L Metric size Upward∗2
Elbow
Decentralised B Downward∗2
S System 2
99
N Straight
(128 points) LN Inch size Upward∗2
Elbow
EX500 Gateway BN Downward∗2
Decentralised CM∗1 Straight
S Serial 105 Mixed sizes
System LM∗1 Elbow (Including upward and downward piping)∗2
transmission (64 points) ∗1 Select CM or LM if mixed port sizes are to be used for each series.
S6 EX600 115 (For example, if mixed sizes, such as C6 and C8, are to be used for
S EX250 133 the SY5000 series) In such cases, indicate the sizes on the manifold
S EX260 141 specification sheet.
The direction of P, E port fittings is the same as for the A, B port. If
S4∗1 EX126 153
selecting “LM,” indicate it on the manifold specification sheet for the P,
S3∗1 EX120 161 E port fitting direction.
∗1 EX126, EX120 are not yet UL-compliant. ∗2 To avoid interference with the body or piping, select a downward
∗ Refer to the pages shown in the table above elbow port when mounting the optional spacer assembly (pages 228
for details. to 230). Elbow fittings are not available for Type 11 (Bottom ported).
∗ Elbow fittings: Ø 1/4" and Ø 5/16" are not available.

e
• With Lead wire
Lead wire length
1 0.6 m
2 1.5 m
3 3m

• With D-sub connector (IP40/67) and


Flat ribbon cable
Connector entry direction
1 Upward
2 Lateral

∗ It is not necessary to select the items above for


the valve with terminal block box or with circular
connector or the serial transmission type.

189
Plug-in Connector Connecting Base SY5000/7000 Series

i SY7000: A, B port size !0 Mounting and Option


(Metric/One-touch fitting) (Inch/One-touch fitting) Option DIN Rail Option
Symbol Mounting — Standard length
Symbol Port size Symbol Port size Name plate Station number
6 Ø6 7 Ø 1/4" — — — 0 Without DIN rail (with bracket)
Direct 3 For 3 stations Specify a longer rail
8 Ø8 9 Ø 5/16" AA mounting  


BA  — than the total length
10 Ø 10 11 Ø 3/8"
12 Ø 12 — For all stations of SY5000 D — — 24 For 24 stations of specified stations.
DIN rail
— For all stations of SY5000 A mounting  
∗ No symbol needs to be specified when fitting type “CM” or “LM” is B  —
selected. ∗ Enter the number of stations inside  when it is larger than the number
of valve stations. (Refer to “DIN Rail Option” above.)

o SY5000: A, B port size ∗
Only direct mounting is available for the type 11 bottom-ported type.
Refer to page 192 to determine the L3 using “Calculation formula” for
(Metric/One-touch fitting) (Inch/One-touch fitting) the DIN rail length. (For the SY3000 and SY5000 mixed mounting type)
Symbol Port size Symbol Port size ∗ The manifold block width is 19 mm for both the SY5000 and SY7000
6 Ø6 7 Ø 1/4" sizes.
∗ Refer to page 319 for the fixation of DIN rail mounting type manifold.
8 Ø8 9 Ø 5/16"
10 Ø 10 11 Ø 3/8"
12 Ø 12
∗ The valve pitch is 19 mm, the same as that of the SY7000.
∗ No symbol needs to be specified when fitting type “CM” or “LM” is
selected.

How to Order Manifold Assembly

Example (SS5Y7-M10F1-)
2-position double
SY5200-5U1 (2 sets)
2-position double
SY7200-5U1 (3 sets) Manifold base (5 stations)
SS5Y7-M10F1-05D-C128

ide
Us
s
at ion
St
3
2
1
ide
Ds

SS5Y7-M10F1-05D-C128 ·· 1 set (Type M10 5-station manifold base part no.)


∗SY7200-5U1 ····················· 3 sets (2-position double part no.)
∗SY5200-5U1 ····················· 2 sets (2-position double part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
• For the valve arrangement, the valve closest to the D side is considered the 1st station.
• Under the manifold part number, state the valves to be mounted in order starting
with the 1st station as shown in the figure above. If the arrangement becomes too
complicated, specify the details on a manifold specification sheet.
∗ When mixing top-ported configurations, select from those listed on page 198.
In such cases, use caution as there is also output on the A and B ports on
the base side.
Protective class
Specify on the manifold specification sheet if plugs are required for the A and
B ports on the base side.
class # (Mark: )
190
SY5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 7 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

q Series y Pilot valve option !0 Manual override


5 SY5000 — Standard (0.7 MPa) —: D:
7 SY7000 B Quick response type (0.7 MPa) Non-locking Push-turn
K∗1 High pressure type (1.0 MPa) push type locking
∗1 Only the metal seal type is available for the slotted
type
w Type of actuation
high pressure type.

1 Single
2
2-position
Double u Coil type E: F:
3 Closed centre — Standard
Push-turn Slide locking
4 3-position Exhaust centre T With power saving circuit (Continuous duty type) locking type
5 Pressure centre ∗ Be sure to select the power saving circuit lever
A∗1 N.C./N.C. type if the valve is to be continuously type
4-position energised for long periods of time.
B∗1 dual 3-port
N.O./N.O.
C∗1 N.C./N.O. ∗ Be careful of the energising time when the
power saving circuit is selected. Refer to
∗1 Only the rubber seal type is available for the page 316 for details. ∗ Refer to page 36 for the safety slide locking
4-position dual 3-port valve. manual override.

i Rated voltage
e Seal type 5 24 VDC !1 Type of mounting screw
0 Rubber seal 6 12 VDC
— Round head combination screw
1 Metal seal ∗ Only 24 VDC is available for the serial B Hexagon socket head cap screw
transmission type.
K Round head combination screw (Drop prevention type)
H Hexagon socket head cap screw (Drop prevention type)
r Pilot type o Light/surge voltage suppressor ∗ For “K” and “H,” the valve body cover has a
drop prevention construction to stop the
— Internal pilot and common specification mounting screws from falling out when the
R External pilot
Symbol With light
Surge voltage Common valve is removed for maintenance, etc.
suppressor specification ∗ When ordering a valve individually, the
— — — base gasket is not included.
R — Non-polar Since the base gasket is attached to the
t Back pressure check valve U 
manifold, please order the base gasket
(Built-in valve type) separately if it is needed for maintenance.
S — Positive Refer to page 222 for base gasket and
— None 
Z  common mounting screw part numbers.
H Built-in NS — Negative ∗ “B” and “H” cannot be selected for the
∗ Only the rubber seal type is available. A NZ  common individual SUP/EXH spacer assembly,
manifold installed type is available if a back ∗ “—” is not available for the SI unit manifold. interface regulator, or double check spacer
pressure check valve with a metal seal is ∗ For the non-polar type, be careful of surge assembly with residual pressure release
required. Refer to page 236 for ordering voltage intrusion. Refer to page 317 for valve.
examples. However, it is not recommended details.
to use the built-in valve type and the manifold ∗ Only “Z” and “NZ” types are available with a
installed type at the same time because it will power saving circuit. Select a valve which is
reduce the flow. suited to the SI unit output polarity or SI unit
∗ The built-in valve type back pressure check specification when the SI unit is selected.
valve is not available for the 3-position type Refer to the pages below for details.
or the SY7000. EX500: pp. 101, 107 EX600: p. 117
EX250: p. 136 EX260: p. 144
EX126: p. 155 EX120: p. 163

Protective class
class # (Mark: )
191
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY3000/5000 Series Connector Connecting Base Mixed Mounting Type

U
SS5Y5-M10- Stations D
B

One-touch fitting
(Station 1)--------- (Station n) [4(A), 2(B) port]
One-touch fitting
Applicable tube O.D.: Ø 2
[4(A), 2(B) port] Compatible with mixed : Ø 3.2, Ø 1/8"
Applicable tube O.D.: Ø 4, Ø 5/32" mounting type: Ø 8, Ø 5/16" : Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"

(Slide locking manual override)


SY3000 : Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"

(SY3000)

(SY3000)
11.1

31.5

78.9
1 P 1 P

73.2
2 B2 B2 B2 B2 B

8.7
3/5 3/5
33.4

E 4 A4 A4 A E
4 A4 A
12.4

14.1
(SY5000 and SY3000: Ø 8, Ø 5/16")
29.1
(SY5000 and SY3000: Ø 8, Ø 5/16")
(11.8)
(For DIN rail mounting)
(7.5)
One-touch fitting 35.9 18 (20.5)
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 10, Ø 3/8" ( Pitch
SY5000 )
of
( Pitch
SY3000 )
of Calculation formula for dimensions with
D-sub connector <IP40> and Flat ribbon
P = 16 P = 12.5 cable

( Pitch
Ø 5/16" )
of SY3000: Ø 8, One-touch fitting
[4(A), 2(B)port]
L1 = 12.5 x n1 + 16 x n2 + 76.4
L2 = 12.5 x n1 + 16 x n2 + 48
P = 16 Applicable tube O.D.: Ø 8, Ø 5/16" M = (L1 + 6.1)/12.5 + 1 Decimal fractions are truncated.
L3 = 12.5 x M + 23
L4 = L3 – 10.5
L5 = (L3 – L1 + 6.1)/2
n1: Number of valve stations of the SY3000
D side U side n2: Number of valve stations of the SY5000
(L5) Manual override (Including the stations of the SY3000: Ø 8,
L1
Ø 5/16")
DIN rail holding screw (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail Light/surge voltage suppressor : Grey (For metal seal)
2(B) port side : Yellow

8
5.5

LOCK

B A B A B A B A B A
35

14 A 14 A 14 A 14 A 14 A
97.5

113.4

FREE
81.2

12 B 12 B
(61.7)
61.7
5.5

12 B 12 B
10.9

4 x M5
4.7
(5.9)
(8.3)

mounting hole
21.9 L2 1.5 (Fitting for the type with P
and E ports on both sides)
5.3 (L4)
(DIN rail mounting hole pitch: 12.5)
(L3) ∗ Refer to pages 177 and 178 for
dimensions of the external pilot,
built-in silencer, and elbow fittings.
Calculation formula for dimensions with D-sub
connector <IP67>, Terminal block box (Spring type),
Terminal block box, Lead wire, Circular connector,
EX500/600/250/260/126/120 serial transmission
L1 = 12.5 x n1 + 16 x n2 + a + b x n3 Coefficient a b c
L2 = 12.5 x n1 + 16 x n2 x 48 D-sub connector <IP67> 90.5 — —
M = L1/12.5 + 1 Decimal fractions are truncated.
L3 = 12.5 x M + 23 Terminal block box (Spring type) 128 — —
L4 = L3 – 10.5 Terminal block box or Serial transmission: EX126 149.3 — —
L5 = (L3 – L1)/2 Lead wire or Circular connector 97 — —
L6 = b x n3 + c
EX500 Gateway Decentralised System 2 (128 points) 88.7 — —
n1: Number of valve stations of the SY3000
n2: Number of valve stations of the SY5000 EX500 Gateway Decentralised System (64 points) 88.5 — —
(Including the stations of the SY3000: Ø 8, Ø 5/16") Serial transmission: EX600 (M12 connector) 141.5 47 81.5
n3: Number of I/O units or input block stations
Serial transmission: EX600 (7/8 inch connector) 158 47 81.5
∗ Refer to pages 120 and 121 for dimensions of the
EX600 serial transmission with I/O unit and page Serial transmission: EX250 141.5 21 81.5
132 for the EX250 serial transmission with input Serial transmission: EX260 88.7 — —
block when L6, b, and c are used for the
calculation formula. Serial transmission: EX120 84.7 — —
192
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported

Dimensions: SY5000/7000 Series Connector Connecting Base Mixed Mounting Type

U
SS5Y7-M10- Stations D
B One-touch fitting (For SY5000)
[4(A), 2(B) port]
Applicable tube O.D.: Ø 6 ,Ø 1/4"
(Station 1) (Station n)
: Ø 8 ,Ø 5/16"
: Ø 10,Ø 3/8"
: Ø 12

manual override)
(Slide locking
85.8
82.7
1 P 1 P
2 B2 B2 B2 B2 B

11.1
3/5 E 3/5 E

8.7
35.2

31.6
4 A4 A4 A4 A4 A
14.2

(10)

(For DIN rail


mounting)
(21.7)

(14.3)
One-touch fitting 39.5 20.5
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 12, Ø 1/2" (Pitch) (Pitch)
P = 19 P = 19

One-touch fitting (For SY7000)


[4(A),2(B) port]
Applicable tube O.D.: Ø 6 ,Ø 1/4"
: Ø 8 ,Ø 5/16"
: Ø 10,Ø 3/8"
: Ø 12

D side U side Manual override

(L5) L1 (
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
DIN rail holding screw : Grey (For metal seal)
(For DIN rail mounting) 2(B) port side : Yellow
Light/surge voltage suppressor (8)

(DIN rail)

LOCK
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
128.8
115

SY5000: 95.7
SY7000: 96.7

FREE
(5.5)
(35)

(77.1)

12 B 12 B 12 B

12 B 12 B
5.5
8.8

3.9
(6)
(9.3)

(17.9)

(A, B port: Ø 12)


4 x M5 mounting hole

(Fitting for the type with P/E


20.7 L2 1.5 ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)

∗ Refer to page 179 for dimensions of the external pilot and built-in silencer.
∗ Refer to the pages below for L1, L2, L3, L4 dimensions and other dimensions that are not specified in each wiring specification.
D-sub connector <IP40> : p. 48
D-sub connector <IP67> : p. 51
Flat ribbon cable : p. 54
Terminal block box (Spring type) : p. 65
Terminal block box : p. 74
Lead wire : p. 84
Circular connector : p. 94
EX500 (128 points) : p. 104
EX500 (64 points) : p. 110
EX600 : pp. 122, 123
EX250 : p. 139
EX260 : p. 150
EX126 : p. 158
EX120 : p. 166

193
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 11/Bottom Ported

Dimensions: SY3000/5000 Series Connector Connecting Base Mixed Mounting Type

U
SS5Y5-M11- Stations D (Pitch of SY3000: Ø 8, Ø 5/16")
P=16
B
(Pitch of SY5000) Panel/fitting dimensions
(Pitch of SY3000)
P=16
P=12.5

7
4.7

35.9 18 (20.5)

)
Ø 8, Ø 5/16"
SY5000 and

60
31.8

SY3000:

(SY3000)
39.7

97.5
49.6
3/5 E 3/5 E
2 B2 B2 B

) (
18

Fitting dimensions for panel 2 B2 B


mounting

(
1 P 1 P
Refer to panel fitting dimensions 4 A4 A4 A

(SY3000)
4 A4 A

Ø 8, Ø 5/16"
SY5000 and
for details.

SY3000:
L2

11
4 x M5 mounting hole

15
4 x Ø 5.5
One-touch fitting

(
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 10, Ø 3/8" One-touch fitting
[4(A), 2(B) port]
One-touch fitting Applicable tube O.D.: Ø 2
[4(A), 2(B) port] One-touch fitting : Ø 3.2, Ø 1/8"
Applicable tube O.D.: Ø 4, Ø 5/32" [4(A), 2(B) port] : Ø 4, Ø 5/32"
: Ø 6, Ø 1/4" Applicable tube O.D.: Ø 8, Ø 5/16" : Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
(Station 1)--------- (Station n)
Compatible with mixed
mounting type: Ø 8, Ø 5/16" Calculation formula for dimensions
SY3000
L1 = 12.5 x n1 + 16 x n2 + a + b x n3
manual override)
(Slide locking

L2 = 12.5 x n1 + 16 x n2 + 48
L6 = b x n3 + c
78.9
73.2

n1: Number of valve stations of the SY3000


n2: Number of valve stations of the SY5000
4.7

(Including the stations of the SY3000:


Ø 8, Ø 5/16")
n3: Number of I/O units or input block stations
(SY3000)
(SY5000)

(Fitting for the type with P


∗ Refer to pages 120 and 121 for dimen-
(12.9)

(7.3)
(9.5)

and E ports on both sides)


sions of the EX600 serial transmission with
I/O unit and page 132 for the EX250 serial
L1 transmission with input block when L6, b,
D side U side
Manual override and c are used for the calculation formula.

(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal) 4 x M5 mounting hole
: Grey (For metal seal)
2(B) port side : Yellow
LOCK

B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
97.5
113.4

FREE
81.2

12 B 12 B
5.5

12 B 12 B
10.9

21.9 L2 1.5

Coefficient a b c
D-sub connector <IP40> or Flat ribbon cable 76.4 — —
D-sub connector <IP67> 90.5 — —
Terminal block box (Spring type) 128 — —
Terminal block box or Serial transmission: EX126 149.3 — —
Lead wire or Circular connector 97 — —
EX500 Gateway Decentralised System 2 (128 points) 88.7 — — ∗ Refer to page 180 for dimensions of the external pilot
EX500 Gateway Decentralised System (64 points) 88.5 — — and built-in silencer.
Serial transmission: EX600 (M12 connector) 141.5 47 81.5
Serial transmission: EX600 (7/8 inch connector) 158 47 81.5
Serial transmission: EX250 141.5 21 81.5
Serial transmission: EX260 88.7 — —
Serial transmission: EX120 84.7 — —
194
SY3000/5000/7000 Series
Plug-in Type 11/Bottom Ported

Dimensions: SY5000/7000 Series Connector Connecting Base Mixed Mounting Type

U
SS5Y7-M11- Stations D ∗ Refer to page 181 for dimensions of the external pilot and built-in silencer.
B ∗ Refer to the pages below for L1, L2 dimensions and other dimensions
that are not specified in each wiring specification.
Dimensions of Type 11/Bottom ported: p. 181
D-sub connector <IP40> : p. 48
D-sub connector <IP67> : p. 51
Flat ribbon cable : p. 54
Terminal block box (Spring type) : p. 65
(Pitch) (Pitch)
Terminal block box : p. 74
39.5 20.5 P = 19 P = 19 (21.7)
Lead wire : p. 84
3.9

Circular connector : p. 94
EX500 (128 points) : p. 104
EX500 (64 points) : p. 110
39.9

48.7
3/5 E 3/5 E
EX600 : pp. 122, 123
2 B2 B2 B2 B2 B
EX250 : p. 139
EX260 : p. 150
21

19.5
4 A4 A4 A4 A4 A
EX126 : p. 158
1 P 1 P
EX120 : p. 166

Fitting dimensions for panel


mounting
Refer to panel fitting
dimensions for details.

One-touch fitting (For SY7000) One-touch fitting (For SY5000)


[4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: Ø 6 ,Ø 1/4" Applicable tube O.D.: Ø 6 ,Ø 1/4"
: Ø 8 ,Ø 5/16" : Ø 8 ,Ø 5/16"
One-touch fitting : Ø 10,Ø 3/8" : Ø 10,Ø 3/8" Panel fitting dimensions
[1(P), 3/5(E) port] : Ø 12 : Ø 12
Applicable tube O.D.: Ø 12,Ø 1/2"

16
(Station 1) (Station n)

60
(Slide locking manual override)

115
2

85.8
82.7
56.6
9.1

L2 4 x M5 mounting hole
4 x Ø 5.5
(12)
(14.5)
(23.9)

(Fitting for the type with P/E


(A, B port: Ø 12) ports on the U and/or D sides)

D side U side
L1
Manual override

(Push-turn locking slotted type:


Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
(Light/surge voltage suppressor)
: Grey (For metal seal)
2(B) port side: Yellow
LOCK

B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
128.8
115

SY5000: 95.7
SY7000: 96.7

FREE

12 B 12 B 12 B

12 B 12 B
5.5
8.8

20.7 L2 1.5 4 x M5 mounting hole

195
196
Plug-in Connector Connecting Base: Plug-in Manifold Mixed Mounting Type
D-sub Connector (IP40/67) Flat Ribbon Cable Terminal Block Box/Spring Type (IP67)
Terminal Block Box (IP67) Lead Wire (IP67) Circular Connector (IP67) EX500 (IP67)
EX600 (IP67) EX245 (IP65) EX250 (IP67) EX260 (IP67) EX126 (IP67) EX120 EX180

Type 12
Top Ported
SY3000/5000/7000 Series
For the SY5000 series, the SY5000 and the SY3000
can be mounted on the same manifold.
For the SY7000 series, the SY7000 and the SY5000
®

∗ Refer to the connector type.

can be mounted on the same manifold. How to Order Manifolds

Refer to pages 183 and 184


for the dimensions of SS5Y 5 M 12 F 1 05 U
Type 12/Top-ported type.
q w e r t y u i
Mixed Mounting Type
For the SY5000 series, it is possible to mount the SY3000 size valves on all
stations. However, the SY3000 manifold block width should be 12.5 mm.
(16 mm for Ø 8 or Ø 5/16" One-touch fitting)
Also, for the SY7000 series, it is possible to mount the SY5000 size valves on t P, E port entry
all stations. However, the SY3000 cannot be mounted onto the SY7000 series. U∗1 U side (2 to 10 stations)
D∗1 D side (2 to 10 stations)
q Series w Connector type B Both sides (2 to 24 stations)
∗1 For type “S”, SUP/EXH block assembly with
5 SY5000 Symbol Type Page
a built-in silencer, choose U or D for P, E
7 SY7000 F D-sub connector IP40 port entry.
FW (25 pins) IP67 ∗ Refer to page 125 for the EX600 and y on
e P 26 pins 55 page 134 for the EX250.
PG Flat ribbon cable 20 pins
• With Lead wire
PH 10 pins y SUP/EXH block assembly
Lead wire length TC Terminal block box (Spring type) 66 — Internal pilot
1 0.6 m T Terminal block box 75 S Internal pilot, Built-in silencer
2 1.5 m L1 34 cores R External pilot
3 3m L2 Lead wire 17 cores 85 ∗ The P and E ports are only available on the U and
L3 9 cores D sides for the built-in silencer type. 3/5(E) port is
M Circular connector 95 plugged. The silencer exhaust port is located on
• With D-sub connector (IP40/67) and
the opposite side of the P and E port entry.
Flat ribbon cable EX500 Gateway (Example: When the P and E port entry is on the
Connector entry direction Decentralised D side, the silencer exhaust port is on the U side.)
S 111
System 2 ∗ Refer to page 125 for the EX600 and y on
1 Upward (128 points) page 134 for the EX250.
2 Lateral
EX500 Gateway
∗ It is not necessary to select the items above for
S
Decentralised
113
i Mounting
the valve with terminal block box or with circular System — Direct mounting
connector or the serial transmission type. Serial (64 points)
transmission D DIN rail mounting (With DIN rail)
S6 EX600 125 D0 DIN rail mounting (Without DIN rail)
r Valve stations SA EX245 127 For 3 Specify a length longer than that
Symbol Stations Note D3 stations of the standard rail.
S EX250 133
02 2 stations Some connectors have a limitation [For the SS5Y5-M12, the SY5000

S EX260 141
valve is now at a mountable
on the number of stations. Refer
S4∗1

EX126 153 For 24 length (manifold block length of


to the pages shown in the table D24
24 24 stations “Connector type” for details. S3∗1 EX120 161 stations 16 mm).]
S8 EX180 169 ∗ Refer to page 199 to determine the L3 using
u P, E port size (One-touch fittings) ∗1 EX126, EX120 are not yet UL-compliant. “Calculation formula” for the DIN rail length.
Symbol SY5000 SY7000 Note ∗ Refer to the pages shown in the table above (For the SY3000 and SY5000 mixed
for details. mounting type)
— Ø 10 Ø 12 Metric size ∗ Refer to page 319 for the fixation of DIN rail
N Ø 3/8" Ø 1/2" Inch size mounting type manifold.

How to Order Manifold Assembly

Example (SS5Y5-M12F1-) 2-position double


2-position double SY3230-5U1-C6 (2 sets)
SY5230-5U1-C8 (3 sets)
Manifold base (5 stations)
SS5Y5-M12F1-05D

SS5Y5-M12F1-05D ··· 1 set (Type M12 5-station manifold base part no.)
∗SY5230-5U1-C8 ········ 3 sets (2-position double part no.)
∗SY3230-5U1-C6 ········ 2 sets (2-position double part no.)
ide The asterisk denotes the symbol for the assembly.
Us Prefix it to the part numbers of the valve, etc.
ns
a tio
St • For the valve arrangement, the valve closest to the D side is considered the 1st station.
3
2 • Under the manifold part number, state the valves to be mounted in order starting
1 with the 1st station as shown in the figure above. If the arrangement becomes too
ide
Ds
complicated, specify the details on a manifold specification sheet.

197
Plug-in Connector Connecting Base SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported

q Series u Coil type !1 A, B port size


3 SY3000 — Standard Thread piping
5 SY5000 T With power saving circuit (Continuous duty type) Symbol Port size Applicable series
7 SY7000 ∗ Be sure to select the power saving circuit M5 M5 x 0.8 SY3000
type if the valve is to be continuously 01 1/8 SY5000
energised for long periods of time. 02 1/4 SY7000
∗ Be careful of the energising time when the
w Type of actuation power saving circuit is selected. Refer to One-touch fitting (Metric)
1 Single page 316 for details. Symbol A, B port SY3000 SY5000 SY7000
2-position
2 Double C2 Ø2  — —
3
4
Closed centre
i Rated voltage C3 Ø 3.2  — —
3-position Exhaust centre C4 Ø4   —
5 24 VDC
5 Pressure centre C6 Ø6   
6 12 VDC
A∗1 N.C./N.C. C8 Ø8 —  
4-position ∗ Only 24 VDC is available for the serial
B∗1 dual 3-port
N.O./N.O. C10 Ø 10 — — 
transmission type.
C∗1 N.C./N.O. C12 Ø 12 — — 
∗1 Only the rubber seal type is available for the
4-position dual 3-port valve. o Light/surge voltage suppressor One-touch fitting (Inch)
and common specification Symbol A, B port SY3000 SY5000 SY7000
Surge voltage Common N1 Ø 1/8"  — —
Symbol With light N3 Ø 5/32"   —
e Seal type — —
suppressor specification
— N7 Ø 1/4"   
0 Rubber seal N9 Ø 5/16" —  
R — Non-polar
1 Metal seal N11 Ø 3/8" — — 
U 
S — Positive

Z  common
r Pilot type NS — Negative !2 Thread type
— Internal pilot NZ  common — Rc
R External pilot ∗ “—” is not available for the SI unit manifold. F G
∗ For the non-polar type, be careful of surge N NPT
voltage intrusion. T NPTF
t Back pressure check valve Refer to page 317 for details.
∗ Only “Z” and “NZ” types are available with a ∗ Only — is available for M5.
(Built-in valve type) power saving circuit. Select a valve which is
— None suited to the SI unit output polarity or SI unit
H Built-in specification when the SI unit is selected.
Refer to the pages below for details. !3 Type of mounting screw
∗ Only the rubber seal type is available. A EX500: pp. 112, 114 EX600: p. 126 — Round head combination screw
manifold installed type is available if a back EX245: p. 127 EX250: p. 141 B Hexagon socket head cap screw
pressure check valve with a metal seal is EX260: p. 152 EX126: p. 160
required. Refer to page 236 for ordering K Round head combination screw (Drop prevention type)
EX120: p. 168 EX180: p. 176 H Hexagon socket head cap screw (Drop prevention type)
examples. However, it is not recommended
to use the built-in valve type and the manifold ∗ For “K” and “H,” the valve body cover has a
installed type at the same time because it will drop prevention construction to stop the
reduce the flow.
∗ The built-in valve type back pressure check
!0 Manual override mounting screws from falling out when the
valve is removed for maintenance, etc.
valve is not available for the 3-position type —: D: ∗ When ordering a valve individually, the
or the SY7000. Non-locking Push-turn base gasket is not included.
push type locking Since the base gasket is attached to the
y Pilot valve option slotted
type
manifold, please order the base gasket
separately if it is needed for maintenance.
— Standard (0.7 MPa) Refer to page 222 for base gasket and
B Quick response type (0.7 MPa) mounting screw part numbers.
K∗1 High pressure type (1.0 MPa) ∗ “B” and “H” cannot be selected for the
∗1 Only the metal seal type is available for the individual SUP/EXH spacer assembly or
high pressure type.
E: F: interface regulator.
Push-turn Slide locking
locking type
lever
type

∗ Refer to page 36 for the safety slide locking


manual override.

Protective class
class # (Mark: )
198
SY3000/5000/7000 Series
Plug-in Type 12/Top Ported

Dimensions: SY5000 Series Connector Connecting Base Mixed Mounting Type

U
SS5Y5-M12- Stations D
B (Station 1)--------- (Station n)
(SY5000)

(SY3000)
(91.3)

(87.4)
1 P 1 P
(69.7)

2 B2 B2 B2 B2 B

3/5 E 4 A4 A4 A 3/5 E ∗ Refer to page 178 for dimensions of


4 A4 A
the external pilot and elbow fittings.

(For DIN rail


mounting)
7.5
11.8
(L5) L1
D side U side

( Pitch of
SY5000 ) Manual override
32.8 21.1 P = 16
Light/surge
voltage suppressor
(
Push-turn locking slotted type:
Press, then rotate it. ) 78.9
(
Pitch of
SY3000 ) 4(A) port side : Blue (For rubber seal)
: Grey (For metal seal)
(Slide locking manual override)
P = 12.5 (65.4)
2(B) port side : Yellow

LOCK
PE
B A B A B A B A B A
5.5

3/5
35

4A 4A
4A 4A 4A

113.4
26.5

FREE
X
1
(SY3000)

81.2
2B 2B
(SY3000)
(SY5000)

61.7
11

56.4
01 : 16.2
C: 14.5
(SY5000)

P
47.3
39.5

2B 2B 2B
2.7
4.7

One-touch fitting
[1(P), 3/5(E) port] One-touch fitting One-touch fitting
Applicable tube O.D.: Ø 10, Ø 3/8" [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: Ø 4, Ø 5/32" Applicable tube O.D.: Ø 2
: Ø 6, Ø 1/4" : Ø 3.2, Ø 1/8"
: Ø 8, Ø 5/16" : Ø 4, Ø 5/32"
5.3 L4 : Ø 6, Ø 1/4"
(DIN rail mounting hole pitch: 12.5)
L3

Calculation formula for dimensions with Calculation formula for dimensions with D-sub
D-sub connector <IP40> and Flat ribbon connector <IP67>, Terminal block box (Spring type),
cable Terminal block box, Lead wire, Circular connector,
L1 = 12.5 x n1 + 16 x n2 + 76.4 EX500/600/250/260/126/120 serial transmission
L2 = 12.5 x n1 + 16 x n2 + 48 L1 = 12.5 x n1 + 16 x n2 + a + b x n3
M = (L1 + 6.1)/12.5 + 1 Decimal fractions are truncated. L2 = 12.5 x n1 + 16 x n2 x 48
L3 = 12.5 x M + 23 M = L1/12.5 + 1 Decimal fractions are truncated.
L4 = L3 – 10.5 L3 = 12.5 x M + 23
L5 = (L3 – L1 + 6.1)/2 L4 = L3 – 10.5
L5 = (L3 – L1)/2
n1: Number of valve stations of the SY3000
L6 = b x n3 + c
n2: Number of valve stations of the SY5000
n1: Number of valve stations of the SY3000
Coefficient n2: Number of valve stations of the SY5000
a b c
n3: Number of I/O units or input block stations
D-sub connector <IP67> 90.5 — —
∗ Refer to pages 120 and 121 for dimensions of the EX600
Terminal block box (Spring type) 128 — — serial transmission with I/O unit and page 132 for the
Terminal block box or Serial transmission: EX126 149.3 — — EX250 serial transmission with input block when L6, b,
and c are used for the calculation formula.
Lead wire or Circular connector 97 — —
EX500 Gateway Decentralised System 2 (128 points) 88.7 — —
EX500 Gateway Decentralised System (64 points) 88.5 — —
Serial transmission: EX600 (M12 connector) 141.5 47 81.5
Serial transmission: EX600 (7/8 inch connector) 158 47 81.5
Serial transmission: EX250 141.5 21 81.5
Serial transmission: EX260 88.7 — —
Serial transmission: EX120 84.7 — —
199
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 12/Top Ported

Dimensions: SY7000 Series Connector Connecting Base Mixed Mounting Type

U
SS5Y7-M12- Stations D
B
(Station 1) (Station n)

(A, B port: Ø 12)


(SY7000)
(112.1)

(SY7000)

(SY5000)
(100.3)

(SY7000)

(98.2)
(SY5000)
88.8

83.8
1 P 1 P
(75.1)

2 B2 B2 B2 B2 B

3/5 E 3/5 E
4 A4 A4 A4 A4 A

D side U side
L1

(Light/surge voltage suppressor)


Manual override

33.9
(Pitch)
26.1 P = 19
(Pitch)
P = 19 42.2 (
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
One-touch fitting
: Grey (For metal seal) 85.8
[1(P), 3/5(E) port] 2(B) port side: Yellow (Slide locking manual override)
Applicable tube O.D.: Ø 12, Ø 1/2"

PE

LOCK
3/5E B A B A B A B A B A
4A 4A 4A 4A 4A
21

128.8

FREE
SY5000: 95.7
SY7000: 96.7
(SY5000)
C: 14.5
01: 16.2

1P
(SY5000)

77.1
(SY7000)

(SY7000)

X 2B 2B 2B
22.6

61.8
59.9

57.7

2B 2B
2.4

1/8
3.9

4 x M5 mounting hole
1/4 [A(A), 2(B) port]
[A(A), 2(B) port]
20.7 L2 1.5
(DIN rail mounting hole pitch: 12.5) One-touch fitting (For SY5000)
[4(A), 2(B) port]
One-touch fitting (For SY7000) Applicable tube O.D.: Ø 4, Ø 5/32"
[4(A), 2(B) port] : Ø 6, Ø 1/4"
Applicable tube O.D.: Ø 6 , Ø 1/4" : Ø 8, Ø 5/16"
: Ø 8 , Ø 5/16"
: Ø 10, Ø 3/8"
: Ø 12

∗ Refer to page 179 for dimensions of the external pilot and elbow fittings.
∗ Refer to the pages below for L1, L2, L3, L4 dimensions and other
dimensions that are not specified in each wiring specification.
Dimensions of Type 12/Top ported: p. 184
D-sub connector <IP40> : p. 48
D-sub connector <IP67> : p. 51
Flat ribbon cable : p. 53
Terminal block box (Spring type) : p. 65
Terminal block box : p. 74
Lead wire : p. 84
Circular connector : p. 94
EX500 (128 points) : p. 104
EX500 (64 points) : p. 110
EX600 : pp. 122, 123
EX250 : p. 139
EX260 : p. 150
EX126 : p. 158
EX120 : p. 166

200
SY3000/5000/7000 Series Type 10, 11, 12
Connector Connecting Base Manifold Exploded View
U side
Manifold Exploded View p. 197

D side

LOC
K
FRE
E

∗ The figures show the SY3000 series.

Wiring
D-sub Connector <IP40> D-sub Connector <IP67> Terminal Block Box Terminal Block Box Lead Wire
/Flat Ribbon Cable p. 203 (Spring
(Spr Type) p. 205 p. 206
p. 202 p. 204

Circular Connector EX500 Gateway Decentralised EX500 Gateway Decentralised EX600


X600 EX245
p. 207 System 2 (128 Points)
Sy System
m (64 Points) p. 210 p. 213
p. 208 p. 209
9

EX250 EX2
2660
EX260 E
EX126 20
EX120 EX
X180
EX180
p. 215 p. 216 p. 217 p. 218 p. 219

201
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series
Wiring
D-sub Connector <IP40>/Flat Ribbon Cable Manifold exploded view

q
U side
Locking bracket
(For D-sub connector)
LOC
Cover assembly K

Silencer cover assembly FRE


E
Port block assembly a
Refer to page 225. Tension
bolt

Holding screw
D side
w Clamp bracket assembly
It is mounted only for the DIN rail mounting type. Refer to pages 221 to 224
The holding screw of the clamp bracket is for details on common parts.
tightened at one point.
(Tightening torque of holding screw: 1.4 N·m)

Manifold Parts Nos.


q SUP/EXH block assembly
Mounting
SY 3 0M 1 11 A 1 C8 — Direct mounting
Series D0 DIN rail mounting (Without DIN rail)
3 SY3000 ∗ For the bottom-ported type, the symbol is —.
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Connector entry direction
1 Upward C8 Ø8  — — Side/Bottom/
SUP/EXH block assembly 2 Lateral C10 Ø 10 —  — Top ported
11 D-sub connector <IP40> C12 Ø 12 — —  Metric size
12 Flat ribbon cable (26 pins) N9 Ø 5/16"  — — Side/Bottom/
Pilot, Silencer/Piping type
13 Flat ribbon cable (20 pins) N11 Ø 3/8" —  — Top ported
Pilot type Built-in Piping
14 Flat ribbon cable (10 pins) Symbol
Internal External silencer direction N13 Ø 1/2" — —  Inch size
 L8 Ø8  — —
Downward elbow Upward elbow

— — — Side ported
S  —  Side L10 Ø 10 —  —
Metric size
R —  — L12 Ø 12 — — 
V  — — LN9 Ø 5/16"  — —
Side ported
RV —  — Top LN11 Ø 3/8" —  —
Inch size
VP  — ∗1 LN13 Ø 1/2" — — 
B  — — B8 Ø8  — —
Side ported
BS  —  Bottom B10 Ø 10 —  —
Metric size
BR —  — B12 Ø 12 — — 
BN9 Ø 5/16"  — —
∗1 For silencer (supply side) Side ported
BN11 Ø 3/8" —  —
E port is plugged. Inch size
∗ “B” for the bottom-ported type can be BN13 Ø 1/2" — — 
selected for the SY5000/7000 series. 00∗1 Plug    P/E port entry on one
00U∗2 Plug    side or Top ported
SUP/EXH block assembly (D side) ∗1 It can be selected only if no symbol or “S” or “V” or “B” is
accessories and the number of accessories selected for the pilot and the piping.
Accessories SY3000 SY5000 ∗2 “00U” is available only for the D-sub connector type and it
SY7000 has an inch size locking bracket.
a Tension bolt None∗1 3 pcs.
∗1 Since the nuts are embedded in the SUP/EXH block

w Clamp bracket assembly


Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A
∗ Part number is for one assembly.

202
SY3000/5000/7000 Series
Wiring
D-sub Connector <IP67> Manifold exploded view

q
U side

Locking a
bracket Tension
bolt

Mounting screw
(Tightening torque: 0.8 N·m)

D side
Holding screw
Refer to pages 221 to 224
e Clamp bracket assembly for details on common parts.
It is mounted only for the DIN rail mounting type.
The holding screws of the clamp bracket is
tightened at two points.
(Tightening torque of holding screw: 1.4 N·m)

Manifold Parts Nos.


q SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 — Direct mounting
Series D0 DIN rail mounting (Without DIN rail)
3 SY3000 ∗ For the bottom-ported type, the symbol is —.
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
C8 Ø8  — — Side/Bottom/
C10 Ø 10 —  — Top ported
C12 Ø 12 — —  Metric size
Pilot, Silencer/Piping type N9 Ø 5/16"  — — Side/Bottom/
Pilot type Built-in Piping N11 Ø 3/8" —  — Top ported
Symbol
Internal External silencer direction N13 Ø 1/2" — —  Inch size
 L8 Ø8  — —
Downward elbow Upward elbow

— — — Side ported
S  —  Side L10 Ø 10 —  —
Metric size
R —  — L12 Ø 12 — — 
V  — — LN9 Ø 5/16"  — —
Side ported
RV —  — Top LN11 Ø 3/8" —  —
Inch size
VP  — ∗1 LN13 Ø 1/2" — — 
B  — — B8 Ø8  — —
Side ported
BS  —  Bottom B10 Ø 10 —  —
Metric size
BR —  — B12 Ø 12 — — 
∗1 For silencer (supply side) BN9 Ø 5/16"  — —
Side ported
E port is plugged. BN11 Ø 3/8" —  —
Inch size
∗ “B” for the bottom-ported type can be BN13 Ø 1/2" — — 
selected for the SY5000/7000 series. 00∗1 Plug    P/E port entry on one
00U∗2 Plug    side or Top ported
SUP/EXH block assembly (D side) ∗1 It can be selected only if no symbol or “S” or “V” or “B” is
accessories and the number of accessories selected for the pilot and the piping.
Accessories SY3000 SY5000 ∗2 “00U” has an inch size locking bracket.
SY7000
a Tension bolt None∗1 3 pcs.
∗1 Since the nuts are embedded in the SUP/EXH block

w D-sub connector block assembly <IP67> e Clamp bracket assembly


Part no. Connector direction Locking bracket Series Part no.
SY30M-14-9A1 Top SY3000 SY30M-15-1A
Metric size
SY30M-14-9A2 Side SY5000/7000 SY50M-15-1A
SY30M-14-9A1U Top ∗ Part number is for one assembly.
Inch size
SY30M-14-9A2U Side

203
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series
Wiring
Terminal Block Box (Spring Type) Manifold exploded view
q
U side

a
Tension
bolt

D side
Mounting screw for
connecting parts Holding Refer to pages 221 to 224
(Tightening torque: screw
for details on common parts.
0.8 N·m)

e Clamp bracket assembly


It is mounted only for the DIN rail mounting type.
The holding screws of the clamp bracket is tightened at two points.
(Tightening torque of holding screw: 1.4 N·m)

Manifold Parts Nos.


q SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 — Direct mounting
Series D0 DIN rail mounting (Without DIN rail)
3 SY3000 ∗ For the bottom-ported type, the symbol is —.
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type
Pilot type C8 Ø8  — — Side/Bottom/
Built-in Piping
Symbol
Internal External silencer direction C10 Ø 10 —  — Top ported
—  — — C12 Ø 12 — —  Metric size
S  —  Side N9 Ø 5/16"  — — Side/Bottom/
R —  — N11 Ø 3/8" —  — Top ported
V  — — N13 Ø 1/2" — —  Inch size
 L8 Ø8  — —
Downward elbow Upward elbow

RV — — Top Side ported


VP  — ∗1 L10 Ø 10 —  —
Metric size
B  — — L12 Ø 12 — — 
BS  —  Bottom LN9 Ø 5/16"  — —
Side ported
BR —  — LN11 Ø 3/8" —  —
Inch size
LN13 Ø 1/2" — — 
∗1 For silencer (supply side)
E port is plugged. B8 Ø8  — —
Side ported
∗ “B” for the bottom-ported type can be B10 Ø 10 —  —
Metric size
selected for the SY5000/7000 series. B12 Ø 12 — — 
BN9 Ø 5/16"  — —
SUP/EXH block assembly (D side) Side ported
BN11 Ø 3/8" —  —
accessories and the number of accessories Inch size
BN13 Ø 1/2" — — 
Accessories SY3000 SY5000
SY7000 00∗1 Plug
P/E port entry on one
  
side or Top ported
a Tension bolt None∗1 3 pcs.
∗1 It can be selected only if no symbol or “S” or “V” or “B” is
∗1 Since the nuts are embedded in the SUP/EXH block
selected for the pilot and the piping.

w Terminal block assembly


SY30M 130 1A
e Clamp bracket assembly
Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A
∗ Part number is for one assembly.

204
SY3000/5000/7000 Series
Wiring
Terminal Block Box Manifold exploded view
Mounting screw q
(Tightening torque: 0.8 N·m)
U side
w

a
Tension
bolt

Mounting screw for


connecting parts Holding D side
(Tightening torque: screw
0.8 N·m) Refer to pages 221 to 224
for details on common parts.
e
r Clamp bracket assembly
It is mounted only for the DIN rail mounting type.
The holding screws of the clamp bracket is tightened at two points.
(Tightening torque of holding screw: 1.4 N·m)

Mounting screw
DIN rail holding screw (Tightening torque: 1.4 N·m)
(Tightening torque: 1.4 N·m)

Manifold Parts Nos.


q SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 — Direct mounting
Series D0 DIN rail mounting (Without DIN rail)
3 SY3000 ∗ For the bottom-ported type, the symbol is —.
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type
Pilot type C8 Ø8  — — Side/Bottom/
Built-in Piping
Symbol
Internal External silencer direction C10 Ø 10 —  — Top ported
—  — — C12 Ø 12 — —  Metric size
S  —  Side N9 Ø 5/16"  — — Side/Bottom/
R —  — N11 Ø 3/8" —  — Top ported
V  — — N13 Ø 1/2" — —  Inch size
 L8 Ø8  — —
Downward elbow Upward elbow

RV — — Top Side ported


VP  — ∗1 L10 Ø 10 —  —
Metric size
B  — — L12 Ø 12 — — 
BS  —  Bottom LN9 Ø 5/16"  — —
Side ported
BR —  — LN11 Ø 3/8" —  —
Inch size
LN13 Ø 1/2" — — 
∗1 For silencer (supply side)
E port is plugged. B8 Ø8  — —
Side ported
∗ “B” for the bottom-ported type can be B10 Ø 10 —  —
Metric size
selected for the SY5000/7000 series. B12 Ø 12 — — 
BN9 Ø 5/16"  — —
SUP/EXH block assembly (D side) Side ported
BN11 Ø 3/8" —  —
accessories and the number of accessories Inch size
BN13 Ø 1/2" — — 
Accessories SY3000 SY5000
SY7000 00∗1 Plug
P/E port entry on one
  
side or Top ported
a Tension bolt None∗1 3 pcs.
∗1 It can be selected only if no symbol or “S” or “V” or “B” is
∗1 Since the nuts are embedded in the SUP/EXH block
selected for the pilot and the piping.

w Terminal block box housing assembly


VVQC1000 T0 1
r Clamp bracket assembly
e Clamp bracket assembly for terminal block box Series Part no.
SY3000 SY30M-15-1A
SY30M 15 4A SY5000/7000 SY50M-15-1A
∗ Part number is for one assembly.
∗ Part number is for one assembly.

205
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series
Wiring
Lead Wire Manifold exploded view

q
U side

w
a
Tension
bolt

Mounting screw
(Tightening torque: 0.8 N·m)
D side

Refer to pages 221 to 224 for


Holding screw details on common parts.
e Clamp bracket assembly
It is mounted only for the DIN rail mounting type.
The holding screws of the clamp bracket is
tightened at two points.
(Tightening torque of holding screw: 1.4 N·m)

Manifold Parts Nos.


q SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 — Direct mounting
Series D0 DIN rail mounting (Without DIN rail)
3 SY3000 ∗ For the bottom-ported type, the symbol is —.
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type
Pilot type C8 Ø8  — — Side/Bottom/
Built-in Piping
Symbol
Internal External silencer direction C10 Ø 10 —  — Top ported
—  — — C12 Ø 12 — —  Metric size
S  —  Side N9 Ø 5/16"  — — Side/Bottom/
R —  — N11 Ø 3/8" —  — Top ported
V  — — N13 Ø 1/2" — —  Inch size
 L8 Ø8  — —
Downward elbow Upward elbow

RV — — Top Side ported


VP  — ∗1 L10 Ø 10 —  —
Metric size
B  — — L12 Ø 12 — — 
BS  —  Bottom LN9 Ø 5/16"  — —
Side ported
BR —  — LN11 Ø 3/8" —  —
Inch size
LN13 Ø 1/2" — — 
∗1 For silencer (supply side)
E port is plugged. B8 Ø8  — —
Side ported
∗ “B” for the bottom-ported type can be B10 Ø 10 —  —
Metric size
selected for the SY5000/7000 series. B12 Ø 12 — — 
BN9 Ø 5/16"  — —
SUP/EXH block assembly (D side) 
Side ported
BN11 Ø 3/8" — —
Inch size
accessories and the number of accessories
BN13 Ø 1/2" — — 
Accessories SY3000 SY5000
SY7000 00∗1 Plug
P/E port entry on one
  
side or Top ported
a Tension bolt None∗1 3 pcs.
∗1 It can be selected only if no symbol or “S” or “V” or “B” is
∗1 Since the nuts are embedded in the SUP/EXH block selected for the pilot and the piping.

w Lead wire connector block assembly


SY30M 14 4A
Number of cores Lead wire length [m]
1 34 1 0.6
2 17 2 1.5
3 9 3 3

e Clamp bracket assembly


Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A
∗ Part number is for one assembly.
206
SY3000/5000/7000 Series
Wiring
Circular Connector Manifold exploded view

q
U side

a
Tension
bolt

Mounting screw
(Tightening torque: 0.8 N·m)
D side

Holding Refer to pages 221 to 224


screw
e Clamp bracket assembly for details on common parts.
It is mounted only for the DIN rail mounting type.
The holding screws of the clamp bracket is
tightened at two points.
(Tightening torque of holding screw: 1.4 N·m)

Manifold Parts Nos.


q SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 — Direct mounting
Series D0 DIN rail mounting (Without DIN rail)
3 SY3000 ∗ For the bottom-ported type, the symbol is —.
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type
Pilot type C8 Ø8  — — Side/Bottom/
Built-in Piping
Symbol
Internal External silencer direction C10 Ø 10 —  — Top ported
—  — — C12 Ø 12 — —  Metric size
S  —  Side N9 Ø 5/16"  — — Side/Bottom/
R —  — N11 Ø 3/8" —  — Top ported
V  — — N13 Ø 1/2" — —  Inch size
 L8 Ø8  — —
Downward elbow Upward elbow

RV — — Top Side ported


VP  — ∗1 L10 Ø 10 —  —
Metric size
B  — — L12 Ø 12 — — 
BS  —  Bottom LN9 Ø 5/16"  — —
Side ported
BR —  — LN11 Ø 3/8" —  —
Inch size
∗1 For silencer (supply side) LN13 Ø 1/2" — — 
E port is plugged. B8 Ø8  — —
Side ported
∗ “B” for the bottom-ported type can be B10 Ø 10 —  —
Metric size
selected for the SY5000/7000 series. B12 Ø 12 — — 
BN9 Ø 5/16"  — —
SUP/EXH block assembly (D side) Side ported
BN11 Ø 3/8" —  —
accessories and the number of accessories Inch size
BN13 Ø 1/2" — — 
Accessories SY3000 SY5000
SY7000 00∗1 Plug
P/E port entry on one
  
side or Top ported
a Tension bolt None∗1 3 pcs. ∗1 It can be selected only if no symbol or “S” or “V” or “B” is
∗1 Since the nuts are embedded in the SUP/EXH block selected for the pilot and the piping.

w Circular connector block assembly


SY30M 14 5A
∗ 26 pins

e Clamp bracket assembly


Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A
∗ Part number is for one assembly.

207
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series
Wiring
EX500 Gateway Decentralised System 2 (128 Points) Manifold exploded view

q
U side
w

a
Tension
bolt

D side

Holding screw Refer to pages 221 to 224


e Clamp bracket assembly for details on common parts.
It is mounted only for the DIN rail mounting type.
The holding screws of the clamp bracket is
tightened at two points.
(Tightening torque of holding screw: 1.4 N·m)

Manifold Parts Nos.


q SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 — Direct mounting
Series D0 DIN rail mounting (Without DIN rail)
3 SY3000 ∗ For the bottom-ported type, the symbol is —.
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type
Pilot type C8 Ø8  — — Side/Bottom/
Built-in Piping
Symbol
Internal External silencer direction C10 Ø 10 —  — Top ported
—  — — C12 Ø 12 — —  Metric size
S  —  Side N9 Ø 5/16"  — — Side/Bottom/
R —  — N11 Ø 3/8" —  — Top ported
V  — — N13 Ø 1/2" — —  Inch size
 L8 Ø8  — —
Downward elbow Upward elbow

RV — — Top Side ported


VP  — ∗1 L10 Ø 10 —  —
Metric size
B  — — L12 Ø 12 — — 
BS  —  Bottom LN9 Ø 5/16"  — —
Side ported
BR —  — LN11 Ø 3/8" —  —
Inch size
LN13 Ø 1/2" — — 
∗1 For silencer (supply side)
E port is plugged. B8 Ø8  — —
Side ported
∗ “B” for the bottom-ported type can be B10 Ø 10 —  —
Metric size
selected for the SY5000/7000 series. B12 Ø 12 — — 
BN9 Ø 5/16"  — —
SUP/EXH block assembly (D side) Side ported
BN11 Ø 3/8" —  —
accessories and the number of accessories Inch size
BN13 Ø 1/2" — — 
Accessories SY3000 SY5000
SY7000 00∗1 Plug
P/E port entry on one
  
side or Top ported
a Tension bolt None∗1 3 pcs. ∗1 It can be selected only if no symbol or “S” or “V” or “B” is
∗1 Since the nuts are embedded in the SUP/EXH block selected for the pilot and the piping.

w EX500 SI unit
EX500 S103
e Clamp bracket assembly
Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A
∗ Part number is for one assembly.

208
SY3000/5000/7000 Series
Wiring
EX500 Gateway Decentralised System (64 Points) Manifold exploded view

q
U side

a
Tension
bolt

Mounting screw
(Tightening torque: 0.8 N·m)

D side

Holding screw Refer to pages 221 to 224


e Clamp bracket assembly for details on common parts.
It is mounted only for the DIN rail mounting type.
The holding screws of the clamp bracket is
tightened at two points.
(Tightening torque of holding screw: 1.4 N·m)

Manifold Parts Nos.


q SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 — Direct mounting
Series D0 DIN rail mounting (Without DIN rail)
3 SY3000 ∗ For the bottom-ported type, the symbol is —.
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type
Pilot type C8 Ø8  — — Side/Bottom/
Built-in Piping
Symbol
Internal External silencer direction C10 Ø 10 —  — Top ported
—  — — C12 Ø 12 — —  Metric size
S  —  Side N9 Ø 5/16"  — — Side/Bottom/
R —  — N11 Ø 3/8" —  — Top ported
V  — — N13 Ø 1/2" — —  Inch size
 L8 Ø8  — —
Downward elbow Upward elbow

RV — — Top Side ported


VP  — ∗1 L10 Ø 10 —  —
Metric size
B  — — L12 Ø 12 — — 
BS  —  Bottom LN9 Ø 5/16"  — —
Side ported
BR —  — LN11 Ø 3/8" —  —
Inch size
LN13 Ø 1/2" — — 
∗1 For silencer (supply side)
E port is plugged. B8 Ø8  — —
Side ported
∗ “B” for the bottom-ported type can be B10 Ø 10 —  —
Metric size
selected for the SY5000/7000 series. B12 Ø 12 — — 
BN9 Ø 5/16"  — —
SUP/EXH block assembly (D side) Side ported
BN11 Ø 3/8" —  —
accessories and the number of accessories Inch size
BN13 Ø 1/2" — — 
Accessories SY3000 SY5000
SY7000 00∗1 Plug
P/E port entry on one
  
side or Top ported
a Tension bolt None∗1 3 pcs. ∗1 It can be selected only if no symbol or “S” or “V” or “B” is
∗1 Since the nuts are embedded in the SUP/EXH block selected for the pilot and the piping.

w EX500 SI unit
EX500 Q 0 01
Output specifications
0 NPN (Positive common)
1 PNP (Negative common)

e Clamp bracket assembly


Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A
∗ Part number is for one assembly.

209
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series
Wiring
EX600 Manifold exploded view

Mounting screw q
(Tightening torque: 0.8 N·m) U side
w

e
a
Tension
t bolt

D side

Refer to pages 221 to 224


for details on common parts.
u

Holding screw

r Clamp bracket assembly


It is mounted only for the DIN rail mounting type.
The holding screws of the clamp bracket is tightened at two points.
(Tightening torque of holding screw: 1.4 N·m)

Manifold Parts Nos.


q SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 — Direct mounting
Series D0 DIN rail mounting (Without DIN rail)
3 SY3000 ∗ For the bottom-ported type, the symbol is —.
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Pilot, Silencer/Piping type Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot type Built-in Piping C8 Ø8  — — Side/Bottom/
Symbol C10 Ø 10 —  — Top ported
Internal External silencer direction
—  — — C12 Ø 12 — —  Metric size
S  —  Side N9 Ø 5/16"  — — Side/Bottom/
R —  — N11 Ø 3/8" —  — Top ported
V  — — N13 Ø 1/2" — —  Inch size
RV —  — Top L8 Ø8  — —
Downward elbow Upward elbow

Side ported
VP  — ∗1 L10 Ø 10 —  —
Metric size
B  — — L12 Ø 12 — — 
BS  —  Bottom LN9 Ø 5/16"  — —
Side ported
BR —  — LN11 Ø 3/8" —  —
Inch size
∗1 For silencer (supply side) LN13 Ø 1/2" — — 
E port is plugged. B8 Ø8  — —
Side ported
∗ “B” for the bottom-ported type can be B10 Ø 10 —  —
Metric size
selected for the SY5000/7000 series. B12 Ø 12 — — 
SUP/EXH block assembly (D side) BN9 Ø 5/16"  — —
Side ported
accessories and the number of accessories BN11 Ø 3/8" —  —
Inch size
BN13 Ø 1/2" — — 
Accessories SY3000 SY5000
SY7000 P/E port entry on one
00∗1 Plug   
a Tension bolt None∗1 3 pcs. side or Top ported
∗1 Since the nuts are embedded in the SUP/EXH block ∗1 It can be selected only if no symbol or “S” or “V” or “B” is
selected for the pilot and the piping.

210
SY3000/5000/7000 Series
Manifold Parts Nos.
w Valve plate
EX600 ZMV2
∗ With mounting screws
(2 pcs. of M4 x 6 and 2 pcs. of M3 x 8)

e EX600 SI unit
EX600 S PR 1
Protocol Version
Symbol Description Symbol Description
PR PROFIBUS DP When MJ, EN, EC, or

DN DeviceNet™ PN is selected
MJ CC-Link A When PR or DN is selected
EN EtherNet/IP™
EC EtherCAT Output type
PN PROFINET Symbol Description Condition
1 PNP (Negative common) Can be selected by all protocols
2 NPN (Positive common) Can be selected by all protocols
3 PNP (Negative common) Can be selected in the case of EN/PN∗1
4 NPN (Positive common) Can be selected in the case of EN/PN∗1
∗1 For EN: Dual port EtherNet/IP™ product
For PN: IO-Link master compatible product

e EX600 SI unit (Wireless compatible)


EX600 W EN 1
Output type
Symbol Description
1 PNP (Negative common)
2 NPN (Positive common)

Protocol
Symbol SI unit type Description
EN Wireless base module EtherNet/IP™∗1
PN Wireless base module PROFINET∗1
SV Wireless remote module —∗1
∗1 The wireless system is suitable for use only in a country where it is
in accordance with the Radio Act and regulations of that country.

r Clamp bracket assembly


Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A
∗ Part number is for one assembly.

211
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series
Manifold Parts Nos.
t EX600 digital input unit
EX600 DX P B
Input type Number of inputs, open circuit detection, and connector
Symbol Description Symbol Number of inputs Open circuit detection Connector
P PNP B 8 No M12 connector (5 pins) 4 pcs.
N NPN C 8 No M8 connector (3 pins) 8 pcs.
C1 8 Yes M8 connector (3 pins) 8 pcs.
D 16 No M12 connector (5 pins) 8 pcs.
E 16 No D-sub connector (25 pins)
F 16 No Spring type terminal block (32 pins)

t EX600 digital output unit


EX600 DY P B
Output type Number of outputs and connector
Symbol Description Symbol Number of outputs Connector
P PNP B 8 M12 connector (5 pins) 4 pcs.
N NPN E 16 D-sub connector (25 pins)
F 16 Spring type terminal block (32 pins)

t EX600 digital input/output unit


EX600 DM P E
Input/Output type Number of inputs/outputs and connector
Symbol Description Symbol Number of inputs Number of outputs Connector
P PNP E 8 8 D-sub connector (25 pins)
N NPN F 8 8 Spring type terminal block (32 pins)

t EX600 analogue input/output unit


EX600 AX A
Analogue input/output Number of input channels and connector
Symbol Description Symbol Number of input channels Connector
AX Analogue input A 2 channels M12 connector (5 pins) 2 pcs.
AY Analogue output

t EX600 analogue input/output unit


EX600 AM B
Analogue input/output Number of input/output channels and connector
Symbol Number of input channels Number of output channels Connector
B 2 channels 2 channels M12 connector (5 pins) 4 pcs.

y EX600 IO-Link master unit


EX600 L A B 1 Caution
The applicable SI unit models are the
PROFINET compatible EX 6 0 0 -SPN 3 and
Port specification Number of ports and connector EX600-SPN4. While there is also an EtherNet/
Symbol Description Symbol Number of ports Connector IP™ compatible made-to-order specification,
A Port class A M12 connector the EX600-SEN3-X80, the manifold will also
B 4 ports need to be made to order in this case.
B Port class B (5 pins) 4 pcs.

u EX600 end plate i Clamp bracket for EX600


EX600 ED 2 EX600 ZMA3
Enclosed parts
Power connector Mounting
Round head screw with washer
Symbol Connector Symbol Description
(M4 x 20) 1 pc.
2 M12 power supply connector, B-coded — Without DIN rail mounting bracket P-tight screw (4 x 14) 2 pcs.
3 7/8 inch power supply connector 3 With DIN rail mounting bracket
M12 power supply connector IN/OUT,
4 A-coded, Pin arrangement 1
M12 power supply connector IN/OUT,
5 A-coded, Pin arrangement 2
∗ The pin layout for the “4” and “5” pin EX600-ED3-
connectors is different.
EX600-ED4/5-
EX600-ED2-
212
SY3000/5000/7000 Series
Wiring
EX245
q

M3 hexagon socket head cap screw


Tightening torque:
(0.75 to 0.85) N·m

Joint assembly

r
Manifold exploded view

Joint assembly U side

a
Tension
bolt

M4 hexagon socket head cap screw


Tightening torque:
(1.2 to 1.4) N·m D side
Modular adapter assembly
Refer to pages 197 to 200
for details about common parts.

Manifold Parts No.


q SUP/EXH block assembly
SY 3 0M 1 1A C8
Series
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000
Symbol P, E port SY3000 SY5000 SY7000 Note
C8 Ø8  — — Side/Bottom/
C10 Ø 10 —  — Top ported
C12 Ø 12 — —  Metric size
N9 Ø 5/16"  — — Side/Bottom/
Pilot, Silencer/Piping type
N11 Ø 3/8" —  — Top ported
Pilot type Built-in Piping N13 Ø 1/2" — —  Inch size
Symbol
Internal External silencer direction L8 Ø8  — —
Downward elbow Upward elbow

—  — — L10 Ø 10 —  —
Side ported
S  —  Side L12 Ø 12 — — 
Metric size
R —  — LN9 Ø 5/16"  — —
V  — — LN11 Ø 3/8" —  —
Side ported
RV —  — Top LN13 Ø 1/2" — — 
Inch size
VP  — ∗1 B8 Ø8  — —
B  — — B10 Ø 10 —  —
Side ported
BS  —  Bottom B12 Ø 12 — — 
Metric size
BR —  — BN9 Ø 5/16"  — —
∗ 1 : For silencer (supply side). E port is Side ported
BN11 Ø 3/8" —  —
Inch size
plugged. BN13 Ø 1/2" — — 
∗: “B” for bottom ported can be selected P/E port entry on one
00∗1 Plug   
side or Top ported
for the SY5000/7000 series.
SUP/EXH block assembly (D side)
∗1: It can be selected only if no symbol or “S” or “V” or “B” is selected for
accessories and the number of accessories the pilot and the piping.
Accessories SY3000 SY5000/7000
aTension bolt None∗1 3 pcs.
∗1: Since the nuts are embedded in the SUP/EXH block.
213
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series

Manifold Parts No.


w EX245 SI Unit

EX245 S PN 1A
SI unit Connector type
PROFINET Symbol Communication connector Power supply connector
1A Push Pull connector (SCRJ): 2 pcs. Push Pull connector (24 V): 2 pcs.
2A Push Pull connector (RJ45): 2 pcs. Push Pull connector (24 V): 2 pcs.
7/8 inch connector (5-pin, Plug): 1 pc.
3A M12 connector (4-pin, Socket, D-coded): 2 pcs.
7/8 inch connector (5-pin, Socket): 1 pc.

e EX245 Digital Input Module

EX245 DX1
Digital input module
specification
DX1 Digital input (16 inputs)

e EX245 Digital Output Module

EX245 DY1
Digital output module
specification
DY1 Digital output (8 outputs)

r EX245 End Plate

EX245 EA2 3

214
SY3000/5000/7000 Series
Wiring
EX250 Manifold exploded view

q
U side

w
r a
Tension
t bolt

y
Holding screw D side

e Clamp bracket assembly Refer to pages 221 to 224


It is mounted only for the DIN rail for details on common parts.
mounting type.
The holding screws of the clamp
bracket is tightened at two points.
(Tightening torque of holding
screw: 1.4 N·m)
Manifold Parts Nos.
q SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 — Direct mounting
Series D0 DIN rail mounting (Without DIN rail)
3 SY3000 ∗ For the bottom-ported type, the symbol is —.
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Pilot, Silencer/Piping type Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot type Built-in Piping C8 Ø8  — — Side/Bottom/
Symbol C10 Ø 10 —  — Top ported
Internal External silencer direction
—  — — C12 Ø 12 — —  Metric size
S  —  Side N9 Ø 5/16"  — — Side/Bottom/
R —  — N11 Ø 3/8" —  — Top ported
V  — — N13 Ø 1/2" — —  Inch size
RV —  — Top L8 Ø8  — —
Downward elbow Upward elbow

Side ported
VP  — ∗1 L10 Ø 10 —  —
Metric size
B  — — L12 Ø 12 — — 
BS  —  Bottom LN9 Ø 5/16"  — —
Side ported
BR —  — LN11 Ø 3/8" —  —
Inch size
∗1 For silencer (supply side). LN13 Ø 1/2" — — 
E port is plugged. B8 Ø8  — —
Side ported
∗ “B” for the bottom-ported type can be B10 Ø 10 —  —
Metric size
SUP/EXH block assembly (D side) selected for the SY5000/7000 series. B12 Ø 12 — — 
accessories and the number of accessories BN9 Ø 5/16"  — —
Side ported
BN11 Ø 3/8" —  —
Accessories SY3000 SY5000
SY7000 BN13 Ø 1/2" — — 
Inch size
a Tension bolt None∗1 3 pcs. P/E port entry on one
00∗1 Plug   
∗1 Since the nuts are embedded in the SUP/EXH block side or Top ported
∗1 It can be selected only if no symbol or “S” or “V” or “B” is
w EX250 SI unit selected for the pilot and the piping.

r Input block
EX250 S DN1
Communication protocol
EX250 IE 1
DN1 DeviceNet™ (Negative common) Block type
PR1 PROFIBUS DP (Negative common) 1 M12 connector, 2 inputs
AS3 AS-Interface (8 in/8 out, 31 slave modes, 2 isolated common type) (Negative common) 2 M12 connector, 4 inputs
AS5 AS-Interface (4 in/4 out, 31 slave modes, 2 isolated common type) (Negative common) 3 M8 connector, 4 inputs
AS7 AS-Interface (8 in/8 out, 31 slave modes, 1 common type) (Negative common)
AS9 AS-Interface (4 in/4 out, 31 slave modes, 1 common type) (Negative common) t EX250 end plate assembly
CA1A CANopen (Negative common)
EN1 EtherNet/IP™ (Negative common) EX250 EA1
∗ With mounting screws (2 pcs. of M3 x 10)
e Clamp bracket assembly
Series Part no. y Clamp bracket assembly for EX250 SI unit
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A SY30M 15 3A
∗ Part number is for one assembly. ∗ Part number is for one assembly.
215
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series
Wiring
EX260 Manifold exploded view
q
U side
w
a
Tension
bolt

Holding screw D side


e Clamp bracket assembly Refer to pages 221 to 224
It is mounted only for the DIN rail mounting type. for details on common parts.
The holding screws of the clamp bracket is tightened at two points. (Tightening torque of holding screw: 1.4 N·m)

Manifold Parts Nos.


q SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 — Direct mounting
Series D0 DIN rail mounting (Without DIN rail)
3 SY3000 ∗ For the bottom-ported type, the symbol is —.
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type
C8 Ø8  — — Side/Bottom/
Pilot type Built-in Piping
Symbol
Internal External silencer direction C10 Ø 10 —  — Top ported
—  — — C12 Ø 12 — —  Metric size
S  —  Side N9 Ø 5/16"  — — Side/Bottom/
R —  — N11 Ø 3/8" —  — Top ported
V  — — N13 Ø 1/2" — —  Inch size
 L8 Ø8  — —
Downward elbow Upward elbow

RV — — Top Side ported


VP  — ∗1 L10 Ø 10 —  —
Metric size
SUP/EXH block assembly (D side) B  — — L12 Ø 12 — — 
accessories and the number of accessories BS  —  Bottom LN9 Ø 5/16"  — —
Side ported
BR —  — LN11 Ø 3/8" —  —
Accessories SY3000 SY5000
SY7000 LN13 Ø 1/2" — — 
Inch size
∗1 For silencer (supply side)
aTension bolt None∗1 3 pcs. E port is plugged. B8 Ø8  — —
Side ported
∗1 Since the nuts are embedded in the ∗ “B” for the bottom-ported type can be B10 Ø 10 —  —
Metric size
SUP/EXH block selected for the SY5000/7000 series. B12 Ø 12 — — 
BN9 Ø 5/16"  — —
Side ported
BN11 Ø 3/8" —  —
Inch size
w EX260 SI unit (Fieldbus and Industrial Ethernet) BN13 Ø 1/2" — — 
P/E port entry on one
00∗1   
EX260 S PR1 Plug
side or Top ported
∗1 It can be selected only if no symbol or “S” or “V” or “B” is selected for the pilot and the piping.
Communication protocol
Number of
Symbol Protocol SI unit output polarity Communication
outputs connector Manifold symbol Symbol Protocol Number of
outputs SI unit output polarity Communication
connector Manifold symbol
DN1 32
Source/PNP (Negative common) QAN EC1 32
Source/PNP (Negative common) DAN
DN2 DeviceNet™ Sink/NPN (Positive common)
M12
QA EC2 EtherCAT Sink/NPN (Positive common)
M12
DA
DN3 16
Source/PNP (Negative common) QBN EC3 16
Source/PNP (Negative common) DBN
DN4 Sink/NPN (Positive common) QB EC4 Sink/NPN (Positive common) DB
PR1 32
Source/PNP (Negative common) NAN PN1 32
Source/PNP (Negative common) FAN
PR2 Sink/NPN (Positive common)
M12
NA PN2 PROFINET Sink/NPN (Positive common)
M12
FA
PR3 16
Source/PNP (Negative common) NBN PN3 16
Source/PNP (Negative common) FBN
PR4 PROFIBUS DP Sink/NPN (Positive common) NB PN4 Sink/NPN (Positive common) FB
PR5 32
Source/PNP (Negative common) NCN EN1 32
Source/PNP (Negative common) EAN
PR6 Sink/NPN (Positive common)
D-sub∗1
NC EN2 EtherNet/IP™ Sink/NPN (Positive common)
M12
EA
PR7 16
Source/PNP (Negative common) NDN EN3 16
Source/PNP (Negative common) EBN
PR8 Sink/NPN (Positive common) ND EN4 Sink/NPN (Positive common) EB
MJ1 32
Source/PNP (Negative common) VAN PL1 Ethernet 32
Source/PNP (Negative common) M12
GAN
MJ2 CC-Link Sink/NPN (Positive common)
M12
VA PL3 POWERLINK 16 GBN
MJ3 16
Source/PNP (Negative common) VBN IL1 IO-Link 32 Source/PNP (Negative common) M12 KAN
MJ4 Sink/NPN (Positive common) VB
∗1 Enclosure is IP40 when the communication connector is D-sub.

EX260 SI Unit (Safety Communication)


EX260 F PS1 e Clamp bracket assembly
Communication protocol Series Part no.
Symbol Protocol Number of outputs SI unit output polarity Communication connector Manifold symbol SY3000 SY30M-15-1A ∗ Part number is for one
PS1 PROFIsafe 32 Source/PNP (Negative common) M12 FPN SY5000/7000 SY50M-15-1A assembly.
216
SY3000/5000/7000 Series
Wiring
EX126 Manifold exploded view

q
U side
w

a
Tension
bolt
e

Mounting screw for D side


connecting parts
(Tightening torque: Refer to pages 221 to 224
Holding screw
0.8 N·m) for details on common parts.
r t Clamp bracket assembly
It is mounted only for the DIN rail mounting type.
The holding screws of the clamp bracket is
tightened at two points.
(Tightening torque of holding screw: 1.4 N·m)

Manifold Parts Nos.


q SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 — Direct mounting
Series D0 DIN rail mounting (Without DIN rail)
3 SY3000 ∗ For the bottom-ported type, the symbol is —.
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type
C8 Ø8  — — Side/Bottom/
Pilot type Built-in Piping
Symbol
Internal External silencer direction C10 Ø 10 —  — Top ported
—  — — C12 Ø 12 — —  Metric size
S  —  Side N9 Ø 5/16"  — — Side/Bottom/
R —  — N11 Ø 3/8" —  — Top ported
V  — — N13 Ø 1/2" — —  Inch size
 L8 Ø8  — —
Downward elbow Upward elbow

RV — — Top Side ported


VP  — ∗1 L10 Ø 10 —  —
Metric size
B  — — L12 Ø 12 — — 
BS  —  Bottom LN9 Ø 5/16"  — —
Side ported
BR —  — LN11 Ø 3/8" —  —
Inch size
LN13 Ø 1/2" — — 
∗1 For silencer (supply side)
E port is plugged. B8 Ø8  — —
Side ported
∗ “B” for the bottom-ported type can be B10 Ø 10 —  —
Metric size
selected for the SY5000/7000 series. B12 Ø 12 — — 
BN9 Ø 5/16"  — —
SUP/EXH block assembly (D side) Side ported
BN11 Ø 3/8" —  —
accessories and the number of accessories Inch size
BN13 Ø 1/2" — — 
Accessories SY3000 SY5000
SY7000 00∗1 Plug
P/E port entry on one
  
side or Top ported
a Tension bolt None∗1 3 pcs. ∗1 It can be selected only if no symbol or “S” or “V” or “B” is
∗1 Since the nuts are embedded in the SUP/EXH block selected for the pilot and the piping.

w EX126 SI unit r Clamp bracket assembly for EX126 SI unit


EX126D SMJ1 SY30M 15 4A
∗ CC-Link (Positive common) ∗ Part number is for one assembly.

e Terminal block plate assembly t Clamp bracket assembly


Series Part no.
VVQC1000 74A 2 SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A
∗ Part number is for one assembly.
217
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series
Wiring
EX120 Manifold exploded view

q
U side

a
Tension
bolt

D side

Holding screw Refer to pages 221 to 224


e Clamp bracket assembly for details on common parts.
It is mounted only for the DIN rail mounting type.
The holding screw of the clamp bracket is
tightened at one point.
(Tightening torque of holding screw: 1.4 N·m)

Manifold Parts Nos.


q SUP/EXH block assembly
Mounting
SY 3 0M 1 16A C8 — Direct mounting
Series D0 DIN rail mounting (Without DIN rail)
3 SY3000 ∗ For the bottom-ported type, the symbol is —.
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type
Pilot type C8 Ø8  — — Side/Bottom/
Built-in Piping
Symbol
Internal External silencer direction C10 Ø 10 —  — Top ported
—  — — C12 Ø 12 — —  Metric size
S  —  Side N9 Ø 5/16"  — — Side/Bottom/
R —  — N11 Ø 3/8" —  — Top ported
V  — — N13 Ø 1/2" — —  Inch size
 L8 Ø8  — —
Downward elbow Upward elbow

RV — — Top Side ported


VP  — ∗1 L10 Ø 10 —  —
Metric size
B  — — L12 Ø 12 — — 
BS  —  Bottom LN9 Ø 5/16"  — —
Side ported
BR —  — LN11 Ø 3/8" —  —
Inch size
LN13 Ø 1/2" — — 
∗1 For silencer (supply side)
E port is plugged. B8 Ø8  — —
Side ported
∗ “B” for the bottom-ported type can be B10 Ø 10 —  —
Metric size
selected for the SY5000/7000 series. B12 Ø 12 — — 
SUP/EXH block assembly (D side)
BN9 Ø 5/16"  — —
accessories and the number of accessories Side ported
BN11 Ø 3/8" —  —
Inch size
Accessories SY3000 SY5000
SY7000 BN13 Ø 1/2" — — 
P/E port entry on one
a Tension bolt None∗1 3 pcs. 00∗1 Plug   
side or Top ported
∗1 Since the nuts are embedded in the SUP/EXH block ∗1 It can be selected only if no symbol or “S” or “V” or “B” is
selected for the pilot and the piping.
w EX120 SI unit
EX120 S DN1
Communication protocol
DN1 DeviceNet™ (Positive common)
CS1 OMRON Corp.: CompoBus/S (16 outputs) (Positive common)
CS2 OMRON Corp.: CompoBus/S (8 outputs) (Positive common)
MJ1 CC-Link (Positive common)
CM1 CompoNet™ NPN (Positive common)
CM3 CompoNet™ PNP (Negative common)

e Clamp bracket assembly


Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A
∗ Part number is for one assembly.
218
SY3000/5000/7000 Series
Wiring
EX180 Manifold exploded view

w
q U side

a
Tension
bolt
e

D side

Refer to pages 221 to 224


Mounting screw Holding screw for details about common parts.
(Tightening torque: 0.8 N·m)

r Clamp bracket assembly


It is mounted only for the DIN rail mounting type.
The holding screws of the clamping bracket is tightened at two points.
(Tightening torque of holding screw: 1.4 N·m)

Manifold Parts No.


q SUP/EXH block assembly
Mounting
SY 3 0M 1 1A C8 — Direct mounting
Series D0 DIN rail mounting (Without DIN rail)
∗: For bottom ported, the symbol is —.
3 SY3000
5 SY5000 P, E port size (One-touch fittings)
7 SY7000 Symbol P, E port SY3000 SY5000 SY7000 Note
Pilot, Silencer/Piping type
C8 Ø8  — — Side/Bottom/
Pilot type Built-in Piping C10 Ø 10 —  — Top ported
Symbol
Internal External silencer direction C12 Ø 12 — —  Metric size
—  — — N9 Ø 5/16"  — — Side/Bottom/
S  —  Side N11 Ø 3/8" —  — Top ported
R —  — N13 Ø 1/2" — —  Inch size
V  — — L8 Ø8  — —
Downward elbow Upward elbow

RV —  — Top L10 Ø 10 —  —
Side ported
VP  — ∗1 L12 Ø 12 — — 
Metric size
B  — — LN9 Ø 5/16"  — —
BS  —  Bottom LN11 Ø 3/8" —  —
Side ported
BR —  — LN13 Ø 1/2" — — 
Inch size
∗1: For silencer (supply side). E port is B8 Ø8  — —
Side ported
plugged. B10 Ø 10 —  —
Metric size
∗: “B” for bottom ported can be selected B12 Ø 12 — — 
for the SY5000/7000 series. BN9 Ø 5/16"  — —
SUP/EXH block assembly (D side) 
Side ported
BN11 Ø 3/8" — —
Inch size
accessories and the number of accessories BN13 Ø 1/2" — — 
P/E port entry on one
Accessories SY3000 SY5000
SY7000 00∗1 Plug   
side or Top ported
Tension bolt None∗1 3 pcs. ∗1: It can be selected only if no symbol or “S” or “V” or “B” is
∗1 Since the nuts are embedded in the SUP/EXH block. selected for the pilot and the piping.

w EX180 Series SI Unit e Connector block assembly


EX180 S DN3 SY30M 14 17A
Protocol Made to Order
DN3 DeviceNet™ (32 points Sink/NPN (Positive common)) (Click here for details.) r Clamp bracket assembly
DN4 DeviceNet™ (16 points Sink/NPN (Positive common)) Protocol Series Part no.
DN5 DeviceNet™ (32 points Source/PNP (Negative common)) EtherCAT® SY3000 SY30M-15-1A
DN6 DeviceNet™ (16 points Source/PNP (Negative common)) AnyWireASLINK SY5000/7000 SY50M-15-1A
MJ3 CC-Link (32 points Sink/NPN (Positive common)) ∗: Part number is for one assembly.
MJ5 CC-Link (32 points Source/PNP (Negative common)) Communication connector type
— T-branch type
A Straight type
∗: Communication and power supply connectors are included.
219
220
SY3000/5000/7000 Series
Manifold Exploded View (Common Parts)
y Valve mounting screw B SUP/EXH end block assembly
Caution (SY7000: 3 pcs.) (Includes a)
Tightening torque U side

M2: 0.16 N·m (SY3000)


M3: 0.8 N·m (SY5000/7000)

∗ Refer to page 222 for order numbers.


a Tension bolt

SUP blocking disk assembly


Refer to “Manifold Options” A-w
A-q ( Tightening torque: 0.8 N·m
SY3000: 2 pcs.
SY5000/7000: 3 pcs.
)
on page 234.
A-e
A-r

u DIN rail
It is mounted only for
the DIN rail mounting
type (with DIN rail.)

A Manifold block
assembly
D side
EXH blocking disk assembly
t Refer to “Manifold Options”
Tie-rod on page 234. Holding screw i Clamp bracket assembly
(SY5000/7000: 3 pcs.) It is mounted only for the DIN
rail mounting type. (Tightening
torque of holding screw: 1.4 N·m)
∗ The figures show the SY3000 series.

Type 10, 11, 12: How to Increase Connector Type Manifolds


1 Loosen the U-side tension bolt a, and remove <For SY3000>
the B SUP/EXH end block assembly.

2 Screw in r tie-rods for additional stations to


the t tie-rod of the manifold.
Screw them in until there is no gap
between the tie-rods. Manifold block assembly∗1

q Base gasket
3 Connect the A manifold block assembly and B
SUP/EXH end block assembly to be added, and
tighten the tension bolt a.
w Connector
gasket

r Tie-rod for
Tightening torque for tension bolt a (M3): 0.8 N·m additional
e Manifold stations
block gasket
Caution
1. Be sure to shut off the power and air supplies before
disassembly.
Furthermore, since air may remain inside the actuator, Gaskets are mounted.
piping and manifold, confirm that the air is completely
exhausted before performing any work. ∗1 Manifold block assembly
2. When disassembly and assembly are performed, air No. Description Quantity Note
leakage may result if the tightening of the tension bolt is
For base, connector,
inadequate. qwe Gasket 3
and manifold block
SY3000: 2 pcs.
Tie-rod for
r additional stations
SY5000: 3 pcs.
SY7000: 3 pcs.
Refer to page 222 for ordering single unit.

221
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series

For SS5Y3-10/11/12, SS5Y5-(M)10/11/12, SS5Y7-(M)10/11/12

No. Description SY3000 SY5000 SY7000 Note


Base gasket Part numbers shown on the left are
A-q SY30M-9-1A SY50M-9-1A SY70M-9-1A
Manifold block assembly

(for connector connecting base) for 10 valves. (10 pcs.)


A-w Connector gasket SX3000-146-2 Supplied individually
A-e Manifold block gasket SY30M-9-2 SY50M-9-2 SY70M-9-2 Supplied individually

SY3000/5000/7000
SY30M-49-2-A SV2000-55-2A-A SY70M-49-2-A∗2 2 pcs. supplied (SY3000),
(10.5 mm pitch) (16 mm pitch) (19 mm pitch) 3 pcs. supplied (SY5000/7000)
Tie-rod for
additional
stations∗1

For mixed mounting of SY3000/5000: SV2000-55-2A-A


A-r
SY3000 A, B port size Ø 8, Ø 5/16"
— 3 pcs. supplied
(16 mm pitch)
For mixed mounting of SY3000/5000: SY50M-49-2
SY3000 except A, B port size Ø 8, Ø 5/16"∗4
— 3 pcs. supplied
(12.5 mm pitch)
: Manifold stations (2 to 24 stations)
SY3000/5000/7000
VVQC1000-TR- SV2000-55-1--A SY70M-49-1--A 2 pcs. supplied (SY3000),
(10.5 mm pitch) (16 mm pitch) (19 mm pitch) 3 pcs. supplied (SY5000/7000)
∗3∗4
SY50M-49-1--A —
t Tie-rod (12.5 mm pitch)
∗∗
SS5Y5-M
Mixed mounting SV2000-55-1--A∗5 —
: Manifold stations (2 to 24 stations)
type manifold (16 mm pitch) 3 pcs. supplied

SY70M-49-1--A
SS5Y7-M∗∗ —
(19 mm pitch)

Round head combination screw


SY3000-23-24A SY5000-221-1A SY7000-221-1A Part numbers shown on the left are as follows.
Valve (M2 x 32) (M3 x 32.5) (M3 x 36.5)SY3000/5000:
y mounting for 10 valves (20 pcs. included)
screw Hexagon socket head cap screw
SY3000-222-1A SY5000-222-1A SY7000-222-1A SY7000:
(M2 x 32) (M3 x 32.5) (M3 x 36.5) for 10 valves (30 pcs. included)
u DIN rail VZ1000-11-1- VZ1000-11-4- Refer to page 227.
i Clamp bracket assembly (for connector connecting base) SY30M-15-1A SY50M-15-1A Supplied individually
a Tension bolt (for connector connecting base)∗6 AC00530 SX3000-145-21 Supplied individually
∗1 The manifold of the SY3000 (SS5Y3-10/11/12) can be assembled by connecting the tie-rods for additional stations for the number of manifold stations.
However, the manifold of the SY5000 or SY7000 (SS5Y5/7-10/11/12 including mixed mounting) cannot be assembled by connecting the tie-rods for
additional stations for the number of manifold stations.
∗2 Includes the case when mounting with the SY5000
∗3 When mounting only the SY3000 (12.5 mm pitch except A, B port size Ø 8, Ø 5/16")
∗4 The port sizes except A, B port size Ø 8, Ø 5/16" are the following: Ø 2, Ø 3.2, Ø 4, Ø 6, Ø 1/8", Ø 5/32", Ø 1/4".
∗5 When mounting only the SY3000 (16 mm pitch A, B port size Ø 8, Ø 5/16")
∗6 For the SY3000 SUP/EXH end block (there are no tension bolts for the SY3000 SUP/EXH block) or the SY5000 and SY7000 SUP/EXH (end) block

222
SY3000/5000/7000 Series

Manifold Parts Nos.


A Manifold block assembly
SY 3 0M 2 1 D A C6
Series A, B port size (One-touch fittings)
3 SY3000 Symbol A, B port SY3000 SY5000 SY7000 Note Symbol A, B port SY3000 SY5000 SY7000 Note
5 SY5000 C2 Ø2  — — L4 Ø4   —
7 SY7000 C3 Ø 3.2  — — L6 Ø6    Side
Side/ ported

Upward elbow
C4 Ø4   — Bottom L8 Ø8 —∗1  
Piping direction Metric
C6 Ø6    ported L10 Ø 10 — —  size
1 Side/Top ported C8 Ø8 —∗1   Metric L12 Ø 12 — — 
2 Bottom ported C10 Ø 10 — —  size LN3 Ø 5/32"  — — Side
∗ “2” (bottom ported) can be C12 Ø 12 — —  LN7 Ø 1/4"   — ported
selected for the N1 Ø 1/8"  — — LN9 Ø 5/16" — ∗1  — Inch
Side/
SY5000/7000 series. N3 Ø 5/32"   — Bottom LN11 Ø 3/8" — —  size
N7 Ø 1/4"    ported B4 Ø4   —
N9 Ø 5/16" —∗1   Inch B6 Ø6    Side

Downward elbow
size ported
N11 Ø 3/8" — —  B8 Ø8 —∗1  
Metric
Single wiring ∗1 Refer to mixed mounting type for Ø 8, Ø 5/16". B10 Ø 10 — —  size
Marked with ß B12 Ø 12 — — 
BN3 Ø 5/32"  — — Side
BN7 Ø 1/4"   — ported
Wiring type
BN9 Ø 5/16" —∗1  — Inch
S Single wiring
BN11 Ø 3/8" — —  size
D Double wiring
00 Plug    Top ported

A Manifold (All parts inside are included.)


block assembly
A Mixed mounting of the SY3000/5000 q Base gasket
Manifold block assembly for mounting the SY3000
w Connector r Tie-rod for
SY50M 2 3 D A C6 gasket
additional
stations
Piping direction A, B port size (One-touch fittings)
3 Side/Top ported Symbol A, B port Note Symbol A, B port Note
4 Bottom ported C2 Ø2 L4 Ø4 Side ported
Downward elbow Upward elbow

Side/Bottom Metric size


C3 Ø 3.2 ported
L6 Ø6
Wiring type C4 Ø4 Metric size LN3 Ø 5/32" Side ported
S Single wiring C6 Ø6 LN7 Ø 1/4" Inch size
D Double wiring N1 Ø 1/8" Side/Bottom B4 Ø4 Side ported
N3 Ø 5/32" ported B6 Ø6 Metric size
N7 Ø 1/4" Inch size BN3 Ø 5/32" Side ported
BN7 Ø 1/4" Inch size
00 Plug Top ported

A Mixed mounting of the SY3000/5000 Gaskets are mounted.


Manifold block assembly for mounting the SY3000 for Ø 8, Ø 5/16"
(A manifold block assembly for mounting the SY3000 valves on the e Manifold block gasket
SY5000 manifolds at A, B port size: Ø 8, Ø 5/16")
Manifold block assembly accessories and
SY50M 2 5 D A C8 the number of accessories
Piping direction A, B port size (One-touch fittings) Accessories SY3000 SY5000
SY7000∗1
5 Side ported Symbol A, B port Note q Base gasket 1 pc.
6 Bottom ported C8 Ø8 Side/Bottom ported Metric size w Connector gasket 1 pc.
N9 Ø 5/16" Side/Bottom ported Inch size e Manifold block gasket 1 pc.
Wiring type L8 Upward Ø 8 Side ported Metric size r Tie-rod assembly for additional stations 2 pcs. 3 pcs.
S Single wiring LN9 elbow Ø 5/16" Side ported Inch size ∗1 Including mixed mounting type
D Double wiring B8 Downward Ø 8 Side ported Metric size
BN9 elbow Ø 5/16" Side ported Inch size

A Mixed mounting of the SY5000/7000


Manifold block assembly for mounting the SY5000
SY70M 2 3 D A C10
Piping direction A, B port size (One-touch fittings)
3 Side/Top ported Symbol A, B port Note Symbol A, B port Note Symbol A, B port Note
4 Bottom ported C6 Ø6 L6 Ø6 B6 Ø6
Downward elbow
Upward elbow

Side/Bottom
C8 Ø8
ported
L8 Ø 8 Side ported B8 Ø8 Side ported
Wiring type C10 Ø 10 Metric size L10 Ø 10 Metric size B10 Ø 10 Metric size
S Single wiring C12 Ø 12 L12 Ø 12 B12 Ø 12
D Double wiring N7 Ø 1/4" Side/Bottom LN11 Ø 3/8" Side ported BN11 Ø 3/8" Side ported
N9 Ø 5/16" ported Inch size Inch size
N11 Ø 3/8" Inch size 00 Plug Top ported
223
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series

Manifold Parts Nos.


B SUP/EXH end block assembly
SY 3 0M 3 1A C8
Series Mounting
3 SY3000 — Direct mounting
5 SY5000 D0 DIN rail mounting (Without DIN rail)
7 SY7000 ∗ For the bottom-ported type, the symbol is —.

Pilot, Silencer/Piping type


Pilot type Built-in Piping
Symbol
Internal External silencer direction
—  — — B SUP/EXH end block assembly
(Includes a)
S  —  Side
R —  —
V  — —
RV —  — Top
VP  — ∗1
B  — —
BS  
A-e
BR —

 —
Bottom
a Tension bolt
∗1 For silencer (supply side)
E port is plugged.
∗ “B” for the bottom-ported type can be selected
( Tightening torque: 0.8 N·m
SY3000: 2 pcs.
SY5000/7000: 3 pcs.
)
for the SY5000/7000 series.

P, E port size (One-touch fittings)


Symbol P, E port SY3000 SY5000 SY7000 Note
C8 Ø8  — —
Side/Bottom/Top ported
C10 Ø 10 —  —
Metric size SUP/EXH end block assembly accessories and the number of accessories
C12 Ø 12 — — 
N9 Ø 5/16"  — — Accessories SY3000 SY5000/7000
N11 Ø 3/8" —  —
Side/Bottom/Top ported a Tension bolt 2 pcs. 3 pcs.
Inch size A-e Manifold block gasket 1 pc.
N13 Ø 1/2" — — 
L8 Ø8  — — Gasket is mounted.
Downward elbow Upward elbow

Side ported
L10 Ø 10 —  —
Metric size
L12 Ø 12 — — 
LN9 Ø 5/16"  — —
Side ported
LN11 Ø 3/8" —  —
Inch size
LN13 Ø 1/2" — — 
B8 Ø8  — —
Side ported
B10 Ø 10 —  —
Metric size
B12 Ø 12 — — 
BN9 Ø 5/16"  — —
Side ported
BN11 Ø 3/8" —  —
Inch size
BN13 Ø 1/2" — — 
P/E port entry on one side
00∗1 Plug   
or Top ported
∗1 It can be selected only if no symbol or “S” or “V” or “B” is selected for
the pilot and the piping.

224
SY3000/5000/7000 Series

Manifold Parts Nos.


 Cover assembly/Silencer cover assembly/Port block assembly for SUP/EXH (end) block assembly
Mounting screw (M3)

Cover assembly
(Internal pilot) SY 3 0M 4 1A
Dent for positioning

Silencer cover assembly


(Internal pilot, Built-in silencer) SY 3 0M 5 1A
P, E port
X, PE port (Plug)

Port block assembly


(Side/Bottom ported, External SY 3 0M 6 1AR 00
pilot, Straight, Downward elbow)
A, B port
One-touch fittings
P, E port
piping direction
(Plug) — Straight, Downward elbow (Side ported)
V Upward elbow (Side ported)
X, PE port
Port block assembly
(Side ported, External pilot, X, PE port One-touch fitting type
Upward elbow) Symbol X, PE port SY3000 SY5000 SY7000
Ø4   —
— Metric size
Ø6 — — 
P port Ø 5/32"   —
E port U Inch size
Ø 1/4" — — 
(Plug)
Port block assembly
(Top ported, Internal pilot,
for silencer (supply side)) SY 3 0M 6 3AV C8
P port
E port
X, PE port
Port block assembly
(Internal pilot: Plug
)
External pilot: One-touch fitting (Top ported, Internal/External
SY 3 0M 6 1A V C8
pilot)
Series Pilot type
3 SY3000 — Internal pilot
5 SY5000 R External pilot
∗ Cover assembly, silencer cover assembly, 7 SY7000
and port block assembly are included in
the SUP/EXH (end) block assembly, but P, E port size (One-touch fittings)
they need to be ordered for piping
direction change.
Symbol P, E port SY3000 SY5000 SY7000
C8 Ø8  — —
Tightening torque for mounting screw C10 Ø 10 —  —
SY3000/5000 (M3): 0.8 N·m C12 Ø 12 — — 
SY7000 (M4): 1.4 N·m N9 Ø 5/16"  — —
N11 Ø 3/8" —  —
N13 Ø 1/2" — — 
Caution
1. Be sure to shut off the power and air supplies before
disassembly.
Furthermore, since air may remain inside the actuator,
piping, and manifold, confirm that the air is completely
exhausted before performing any work.
2. When disassembly and assembly are performed, air
leakage may result if the tightening of the cover and port
block assemblies are inadequate.

225
SY3000/5000/7000 Series
One-touch Fitting, Plug Assembly Part Nos.
Refer to “How to Replace One-touch Fittings” on page 320 for the replacement method.

 One-touch fittings
Port size SY3000 SY5000 SY7000
Ø2 VVQ1000-50A-C2 — —
Ø 3.2 VVQ1000-50A-C3 — —
Ø4 VVQ1000-50A-C4 VVQ1000-51A-C4 —
Ø6 Straight type VVQ1000-50A-C6 VVQ1000-51A-C6 VVQ2000-51A-C6
Ø8 — VVQ1000-51A-C8 VVQ2000-51A-C8
Ø 10 — — VVQ2000-51A-C10
Ø 12 — — KQ2H12-17-X224
Metric size

Ø4 SZ3000-73-1A-L4 SZ3000-74-1A-L4 —
Ø6 SZ3000-73-1A-L6 SZ3000-74-1A-L6 SZ3000-83-1A-L6
Ø8 Elbow type — SZ3000-74-1A-L8 SZ3000-83-1A-L8
Ø 10 — — SZ3000-83-1A-L10
Ø 12 — — KQ2L12-17N-X224
Ø4 SZ3000-73-2A-L4 SZ3000-74-2A-L4 —
Ø6 SZ3000-73-2A-L6 SZ3000-74-2A-L6 SZ3000-83-2A-L6
A, B port∗1

Ø8 Long elbow type — SZ3000-74-2A-L8 SZ3000-83-2A-L8


Ø 10 — — SZ3000-83-2A-L10
Ø 12 — — KQ2W12-17N-X224
Ø 1/8" VVQ1000-50A-N1 — —
Ø 5/32" VVQ1000-50A-N3 VVQ1000-51A-N3 —
Ø 1/4" Straight type VVQ1000-50A-N7 VVQ1000-51A-N7 VVQ2000-51A-N7
Ø 5/16" — VVQ1000-51A-N9 VVQ2000-51A-N9
Ø 3/8" — — VVQ2000-51A-N11
Inch size

Ø 5/32" KJL03-95-X224 — —
Ø 1/4" KJL07-95-X224 KQ2L07-14-X224 —
Elbow type
Ø 5/16" — KQ2L09-14-X224 —
Ø 3/8" — — KQ2L11-14-X224
Ø 5/32" KJL03-95-X225 — —
Ø 1/4" KJL07-95-X225 KQ2L07-14-X225 —
Long elbow type
Ø 5/16" — KQ2L09-14-X225 —
Ø 3/8" — — KQ2L11-14-X225
Ø8 VVQ1000-51A-C8 — —
Ø 10 Straight type — VVQ2000-51A-C10 —
Ø 12 — — VVQ4000-50B-C12
Metric size

Ø8 SZ3000-74-1A-L8 — —
Ø 10 Elbow type — SZ3000-83-1A-L10 —
Ø 12 — KQ2L12-19N-X224
Ø8 SZ3000-74-2A-L8 — —
Ø 10 Long elbow type — SZ3000-83-2A-L10 —
P, E port

Ø 12 — — KQ2W12-19N-X224
Ø 5/16" VVQ1000-51A-N9 — —
Ø 3/8" Straight type — VVQ2000-51A-N11 —
Ø 1/2" — — VVQ4000-50B-N13
Inch size

Ø 5/16" KQ2L09-14-X224 — —
Ø 3/8" Elbow type — KQ2L11-14-X224 —
Ø 1/2" — — KQ2L13-19N-X224
Ø 5/16" KQ2L09-14-X225 — —
Ø 3/8" Long elbow type — KQ2L11-14-X225 —
Ø 1/2" — — KQ2W13-19N-X224
∗1 A and B ports (Ø 8 and Ø 5/16") of the SY3000 and 5000 mixed mounting type are the same as those of the SY5000.
∗ Purchasing order is available in units of 10 pieces. Additionally, when performing the piping in the same orientation using the elbow type, please order
“elbow type” or “long elbow type” appropriately.
∗ Select the same port size for both the A and B ports.

 Plug assembly
SY3000 SY5000 SY7000
A, B port VVQ0000-58A VVQ1000-58A VVQ2000-58A
P, E port VVQ1000-58A VVQ2000-58A SY9000-62-1A
∗ Purchasing order is available in units of 10 pieces.

226
SY3000/5000/7000 Series
Manifold Options
 DIN rail dimensions/weight for the SY3000/5000 Plug-in connector connecting base
VZ1000-11-1-
∗ After confirming the L3 dimension in the dimensions table of each series, refer to the DIN rail dimensions table below and
specify the number in the box .
L
8 (7.5)
5.5

(35)
(25)
Rail mounting hole pitch 12.5

No. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
L dimension 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 273 285.5 298 310.5 323
Weight [g] 17.6 19.9 22.1 24.4 26.6 28.9 31.1 33.4 35.6 37.9 40.1 42.4 44.6 46.9 49.1 51.4 53.6 55.9 58.1
No. 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
L dimension 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 523 535.5 548 560.5
Weight [g] 60.4 62.5 64.9 67.1 69.4 71.6 73.9 76.1 78.4 80.6 82.9 85.1 87.4 89.6 91.9 94.1 96.4 98.6 100.9
No. 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56
L dimension 573 585.5 598 610.5 623 635.5 648 660.5 673 685.5 698 710.5 723 735.5 748 760.5 773 785.5 798
Weight [g] 103.1 105.4 107.6 109.9 112.1 114.4 116.6 118.9 121.1 123.4 125.6 127.9 130.1 132.4 134.6 136.9 139.1 141.4 143.6
No. 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71
L dimension 810.5 823 835.5 848 860.5 873 885.5 898 910.5 923 935.5 948 960.5 973 985.5
Weight [g] 145.9 148.1 150.4 152.6 154.9 157.1 159.4 161.6 163.9 166.1 168.4 170.6 172.9 175.1 177.4

 DIN rail dimensions/weight for the SY7000 Plug-in connector connecting base
VZ1000-11-4-
∗ After confirming the L3 dimension in the dimensions table of each series, refer to the DIN rail dimensions table below and
specify the number in the box .
L
8
5.5

(35)
(25)

Rail mounting hole pitch 12.5 (10)

No. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
L dimension 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 273 285.5 298 310.5 323
Weight [g] 24.8 28 31.1 34.3 37.4 40.6 43.8 46.9 50.1 53.3 56.4 59.6 62.7 65.9 69.1 72.2 75.4 78.6 81.7
No. 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
L dimension 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 523 535.5 548 560.5
Weight [g] 84.9 88 91.2 94.4 97.5 100.7 103.9 107 110.2 113.3 116.5 119.7 122.8 126 129.2 132.3 135.5 138.6 141.8
No. 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56
L dimension 573 585.5 598 610.5 623 635.5 648 660.5 673 685.5 698 710.5 723 735.5 748 760.5 773 785.5 798
Weight [g] 145 148.1 151.3 154.5 157.6 160.8 163.9 167.1 170.3 173.4 176.6 179.8 182.9 186.1 189.2 192.4 195.6 198.7 201.9
No. 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71
L dimension 810.5 823 835.5 848 860.5 873 885.5 898 910.5 923 935.5 948 960.5 973 985.5
Weight [g] 205.1 208.2 211.4 214.5 217.7 220.9 224 227.2 230.4 233.5 236.7 239.8 243 246.2 249.3

227
Manifold Options SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options ∗ Refer to pages 239 to 241 for dimensions. M3: 0.8 N·m (SY5000/7000)

 Individual SUP spacer assembly How to Order Individual SUP/EXH Spacer Assembly
[With a connector gasket, a base gasket, and two mounting screws One-touch fitting
(3 pcs. for the SY7000)] Straight type SY 3 0M 38 1 A C6
When the same manifold is used for different pressures, an individual
SUP spacer assembly is used as a supply port for different pressures. One-touch fitting
∗ When selecting a One-touch fitting elbow type for a spacer assembly, Elbow type SY 3 0M 38 2 A L6
use it faced upward, since it interferes with A and B port piping of
Type 10 manifolds.
Series
∗ When the elbows are facing upward in A and B ports in Type 10 3 SY3000
manifolds, they will interfere with the piping for the spacer assem- 5 SY5000
bly. Therefore, combine the A and B ports with straight types or 7 SY7000
elbows facing downward.
Spacer type
4(A) 38 Individual SUP spacer
2-position single valve 2(B)
Individual SUP spacer
39 Individual EXH spacer
assembly
Mounting
1(P') Individual SUP/EXH spacer assembly
screw 5(EA) 2 Short elbow type
1(P) 3 Long elbow type
3(EB)
Circuit diagram ∗ Select the long elbow type for a 3-position valve when
Base gasket
(Mounting example of a using Type 11 and Type 12 downward. However,
2-position single valve) Type 11 of the SY3000 series for the mixed mounting
of connector connecting bases cannot be used
Part numbers of mounting downward.
screw (For repairs)
SY3000: SY3000-23-12A (2 pcs.)
SY5000: SY5000-221-2A (2 pcs.) Port size (Metric/One-touch fittings)
Connector gasket SY7000: SY7000-221-2A (3 pcs.) Symbol P, E port SY3000 SY5000 SY7000
L4 Ø4   —
L6 Ø6   
L8 Ø8 —  
 Individual EXH spacer assembly L10 Ø 10 — — 
[With a connector gasket, a base gasket, and two mounting screws L12 Ø 12 — — 
(3 pcs. for the SY7000)]
Port size (Inch/One-touch fittings)
When valve exhaust affects other stations due to the circuit
configuration, this spacer assembly is used for individual valve exhaust. Symbol P, E port SY3000 SY5000 SY7000
LN3 Ø 5/32"  — —
∗ When selecting a One-touch fitting elbow type for a spacer assembly,
use it faced upward, since it interferes with A and B port piping of LN7 Ø 1/4"   —
Type 10 manifolds. LN9 Ø 5/16" —  —
∗ When the elbows are facing upward in A and B ports in Type 10 LN11 Ø 3/8" — — 
manifolds, they will interfere with the piping for the spacer assem-
bly. Therefore, combine the A and B ports with straight types or el- Port size (Metric/One-touch fittings)
bows facing downward.
Symbol P, E port SY3000 SY5000 SY7000
4(A) C2 Ø2  — —
2-position single valve 2(B) C3 Ø 3.2  — —
Individual EXH spacer C4 Ø4   —
assembly C6 Ø6   
3/5(E') C8 Ø8 —  
Mounting
screw 5(EA) C10 Ø 10 — — 
1(P) C12 Ø 12 — — 
3(EB)
Circuit diagram Port size (Inch/One-touch fittings)
Base gasket (Mounting example of a
2-position single valve) Symbol P, E port SY3000 SY5000 SY7000
N1 Ø 1/8"  — —
Part numbers of mounting N3 Ø 5/32"   —
screw (For repairs) N7 Ø 1/4"   
SY3000: SY3000-23-12A (2 pcs.) N9 Ø 5/16" —  
SY5000: SY5000-221-2A (2 pcs.) N11 Ø 3/8" — — 
Connector gasket SY7000: SY7000-221-2A (3 pcs.) ∗ When using in combination with the SY 57 30 01 -1-E (With
residual pressure release valve), the length of the required
mounting screws will differ. Please contact SMC for details.

Port size Flow rate characteristics


Model 1, 3/5 4, 2 1 → 4/2 (P → A/B) 4/2 → 3/5 (A/B → E)
(P, E) (A, B) C [dm3/(s·bar)] b C [dm3/(s·bar)] b
SY30M-38-1A-C6 1.2 0.32 1.4 0.24
C8 C6
SY30M-39-1A-C6 1.2 0.27 1.1 0.27
SY50M-38-1A-C8 2.7 0.36 3.3 0.22
C10 C8
SY50M-39-1A-C8 2.2 0.37 2.2 0.36
SY70M-38-1A-C12 4.8 0.26 4.7 0.25
C12 C12
SY70M-39-1A-C12 4.9 0.28 4.7 0.23
∗ Calculation of effective area S and sonic conductance C: S = 5.0 x C
∗ The value is for manifold base with 5 stations, rubber seal, and individually operated 2-position type.
∗ For connector connecting base (type 10) manifolds

228
SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options ∗ Refer to pages 239 to 241 for dimensions. M3: 0.8 N·m (SY5000/7000)

 SUP stop valve spacer assembly with residual pressure release valve
[With a connector gasket, a base gasket, and two mounting screws
(3 pcs. for the SY7000)]
It is used to shut off the supply air to valves individually.
∗ Cannot be selected when the elbows are facing upward in A and B ports in Type
10 manifolds, since they will interfere with the piping for the spacer assembly

2-position single valve


SY 3 0M 50 1A E 4(A)
2(B)

Series Manual override


3 SY3000 Push-turn Base gasket
5 SY5000 — locking EXH.
5(EA) Mounting screw
7 SY7000 slotted type 1(P) Connector gasket
3(EB)
Push-turn SUP stop valve spacer assembly
E locking Part numbers of mounting
with residual pressure release valve screw (For repairs)
lever type Circuit diagram
(Mounting example of a 2-position single valve) SY3000: SY30M-56-1A (2 pcs.)
SY5000: SY50M-56-1A (2 pcs.)
∗ For lever type: SY7000: SY70M-56-1A (3 pcs.)
When locking the lever type manual override, push the lever down in the
PUSH position with your fingers until it stops, then turn the lever 90° clockwise.
(PUSH → LOCK)
Turning the lever without pushing it down until it stops can cause damage to
the manual override and other problems such as air leakages.
To unlock the manual override, turn the lever counterclockwise. (LOCK → PUSH)

[How to mount SUP stop valve spacer assembly with residual pressure release valve] Valve mounting screw (Refer to page 222.)
Insert the SUP stop valve mounting screw from the side of the spacer assembly, Tightening torque:
and mount it to the manifold. SY3000 series: 0.16 N·m
Tighten the SUP stop valve mounting screw to the specified tightening torque. SY5000/7000 series: 0.8 N·m
Mount the valve and tighten the valve mounting screws to the specified For hexagon socket head cap screws
Nominal wrench size:
tightening torque after mounting the SUP stop valve spacer assembly with
SY3000 series: 1.5
residual pressure release valve. SY5000/7000 series: 2.5
Valve

∗ Install the plate type nut to the spacer assembly as shown in the figure if it SUP stop valve spacer assembly with
comes off. The SUP stop valve mounting screws can be tightened with a residual pressure release valve
hexagon wrench without removing the plate type nut.
∗ When the elbows are facing upward in A and B ports in Type 1 0 manifolds, Plate type nut
Hexagon wrench
SY3000 series:
they will interfere with the piping for the spacer assembly. Therefore, combine Nominal wrench size:
SY30M-57-1A (10 pcs. included)
the A and B ports with straight types or elbows facing downward. SY5000/7000 series: SY3000 series: 1.3
∗ This product is only for internal pilot specifications, as the external pilot air SY50M-57-1A (10 pcs. included) SY5000/7000 series: 2
cannot be shut off.
∗ If the product is equipped with a 3 -position closed centre, residual pressure SUP stop valve mounting screw
cannot be released, so use in combination with a 3 -port valve, which can be Tightening torque:
connected to the A, B piping port. SY3000 series: 0.16 N·m
SY5000/7000 series: 0.8 N·m

Port size Flow rate characteristics


Model 1, 3/5 4, 2 1 → 4/2 (P → A/B) 4/2 → 3/5 (A/B → E)
(P, E) (A, B) C [dm3/(s·bar)] b C [dm3/(s·bar)] b
SY30M-50-1A(E) C8 C6 0.6 0.18 1.4 0.29
SY50M-50-1A(E) C10 C8 1.6 0.20 3.1 0.23
SY70M-50-1A(E) C12 C12 3.1 0.18 4.3 0.32
∗ Calculation of effective area S and sonic conductance C: S = 5.0 x C
∗ The value is for manifold base with 5 stations, rubber seal, and individually operated 2-position type.
∗ For connector connecting base (type 10) manifolds

229
Manifold Options SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options ∗ Refer to pages 239 to 241 for dimensions. M3: 0.8 N·m (SY5000/7000)

 Double check spacer assembly with residual pressure release valve (Side/Bottom ported) <Example>
[With a connector gasket, a base gasket, and two mounting screws (3 pcs. for the SY7000)] Double check spacer assembly with residual pressure release valve
It is used to hold the intermediate position of the cylinder for a long period of time. Use a 3-position 3-position exhaust centre valve
exhaust centre valve when the double check spacer assembly with residual exhaust valve is used.
It can also be used for drop prevention at the cylinder stroke end when supply residual
pressure is released by using a 2-position single/double valve.
∗ When the elbows are facing upward in A and B ports in Type 10 manifolds, they will interfere with the piping for
the spacer assembly. Therefore, combine the A and B ports with straight types or elbows facing downward.

Series Part no. Intermediate stop Drop prevention


4(A) 2(B) EXH.
SY3000 SY30M-60-1A Applicable 3 3 5(EA)
SY 5 40 01 SY 5 12 001 1(P)
SY5000 SY50M-60-1A valve 7 7
3(EB)
SY7000 SY70M-60-1A Circuit diagram
(Intermediate stop: When 3-position exhaust centre valve is mounted)

Double check spacer assembly with residual pressure release valve


2-position single valve

Mounting screw

Part numbers of mounting


screw (For repairs)
4(A) 2(B) EXH.
SY3000: SY3000-23-27A (2 pcs.) 5(EA)
SY5000: SY5000-221-4A (2 pcs.) 1(P)
3(EB)
SY7000: SY7000-221-4A (3 pcs.) Circuit diagram
(Drop prevention: When 2-position single valve is mounted)

Base gasket Caution


• Air leakage from the pipe between the valve and cylinder or from the fittings will prevent the cylinder
from stopping for a long period of time. Check the leakage using neutral household detergent, such as
dish washing soap. Also, check the cylinder’s tube gasket, piston seal, and rod seal for air leakage.
• Combining with 3-position closed centre or pressure centre valve will not work.
• If the exhaust of the double check spacer is restricted too much, the cylinder may not operate properly
Connector gasket and may not stop intermediately.
• Set the cylinder load so that the cylinder pressure will be within two times that of the supply pressure.
• If using a double check spacer that is built in to the sub-plate, refer to page 307.

Specifications
Max. operating pressure 1.0 MPa
Min. operating pressure 0.1 MPa
Ambient and fluid temperatures –10 to 50 °C
SY3000 0.3 dm3/(s·bar)
Flow rate
characteristics: C
SY5000 0.7 dm3/(s·bar)
SY7000 1.1 dm3/(s·bar)
Max. operating frequency 3 Hz

 Blanking plate assembly How to Order Blanking Plate Assembly


[With two mounting screws (3 pcs. for the SY7000)]
Used when valve additions are expected or for maintenance. A SY 3 0M 26 1A
structure is in place on the blanking plate to prevent the mounting
screws from sliding. Series Option for mounting
3 SY3000 — With mounting screw (Round head combination screw)
Mounting screw 5 SY5000 B With mounting screw (Hexagon socket head cap screw)
Mounting screw Mounting screw (3 pcs.) 7 SY7000
(2 pcs.) (2 pcs.)
(A) (B) Part numbers of mounting screw [Hexagon bolt] (For repairs)
4 2 SY3000: SY3000-23-24A [SY3000-222-1A]
SY5000: SY5000-221-1A [SY5000-222-1A]
SY7000: SY7000-221-2A [SY7000-222-1A]
5 1 3
(EA) (P) (EB)
Circuit diagram
SY30M-26-1A(-B) SY50M-26-1A(-B) SY70M-26-1A(-B) Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
∗ Refer to pages 239 to 241 for dimensions. M3: 0.8 N·m (SY5000/7000)

230
SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options ∗ Refer to pages 239 to 241 for dimensions. M3: 0.8 N·m (SY5000/7000)

 Interface regulator
[With a connector gasket, a base gasket, and two mounting screws (3 pcs. for the SY7000)]
Used when the supply pressure for each valve on the same manifold must be individually set (reduced pressure).

How to Order

SY 3 0M 05 P
Series Applicable valve∗3
3 SY3000 — For single, double, and 4-position
3 For 3-position
Pressure gauge option∗1 ∗1 In the case of the SY3000 series with a pressure gauge, when mounting on the manifold, use
M1 Without pressure gauge caution that the part numbers are different between the odd no. stations and the even no. stations
05 Pressure gauge with MPa display (For odd number station) to prevent the pressure gauges from interfering with each other.
06 Pressure gauge with MPa display (For even number station) If using a connector connecting base M10/11/12 (mixed mounting type) or laminating two or more
types of spacer type manifold options for the neighbouring stations, you can use only the model
N5 Pressure gauge with psi display (For odd number station)∗2
without a pressure gauge (M1).
N6 Pressure gauge with psi display (For even number station)∗2 ∗2 As per the new Measurement Law, gauges with a psi display will only be sold to overseas
customers.
∗3 In the case of the SY3000 series, use caution that the part numbers will differ depending on the
SY 5 0M 00 P one for single/double and 4- and 3-position due to the different length of solenoid valves. Also, if
you have selected a model with a pressure gauge, and if at least the one for 3-position is included
in the same manifold, use all the ones for 3-position to prevent the pressure gauges from
Series interfering with each other.
5 SY5000
7 SY7000 Regulating port
P 1(P) port Part numbers of mounting
Pressure gauge option A1 4(A) port (P controlled type, A port regulation) screw (For repairs)
M1 Without pressure gauge B1 2(B) port (P controlled type, B port regulation) SY3000: SY3000-23-12A (2 pcs.)
00 Pressure gauge with MPa display SY5000: SY5000-221-6A (2 pcs.)
N0 Pressure gauge with psi display∗2 SY7000: SY7000-221-6A (3 pcs.)

Mounting screw

Base gasket

Connector gasket

SY30M-05/N5- SY30M-06/N6- SY30M-M1- SY50M-00/N0- SY50M-M1- SY70M-00/N0- SY70M-M1-


(With pressure gauge/ (With pressure gauge/ (Without pressure gauge) (With pressure gauge) (Without pressure gauge) (With pressure gauge) (Without pressure gauge)
For odd number station) For even number station)

Specifications

Interface regulator model SY30M--- SY50M-- SY70M-- ∗1 3-position closed centre and pressure centre, and 4-position
Applicable valve model∗1 SY3 03 (R) SY5 03 (R) SY7 03 (R) dual 3-port valves are only available for 1(P) port pressure
regulation.
Regulating port 1(P), 4(A), 2(B)
∗2 Gasket and mounting screws are included in the weight.
Set pressure range 0.1 to 0.7 MPa ∗3 ( ): Denotes the values of SY30M---3
Maximum operating pressure 1.0 MPa ∗ Always apply pressure from 1(P) port in the base for interface
Fluid Air regulator.
Ambient and fluid temperatures –10 to 50 °C (No freezing) ∗ When using in combination with the SY 57 30 01 -1-E (With
With pressure gauge 33 (35)∗3 75 93 residual pressure release valve), the length of the required
Weight [g]∗2 mounting screws will differ. Please contact SMC for details.
Without pressure gauge 27 (29)∗3 69 87

Symbol (A)4 2(B)


(A)4 2(B)
2(B) (A)4

(EA)5 3(EB)
(EA)5 3(EB) (EA)5 3(EB)

1 4(A) port regulation 2(B) port regulation


1(P) port regulation (P) 1 1
(P controlled type, A port regulation) (P) (P controlled type, B port regulation) (P)

231
Manifold Options SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options: Spacer Combinations and Screw List q M3: 0.8 N·m (SY5000/7000)

q
q SY3000 (M2) w
w SY5000 (M3) e
e SY7000 (M3)
Combination
Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw

<Round head combination screw> SY3000- SY3000- SY5000- SY5000- SY7000- SY7000-
q: SY3000-23-24A A Valve 23-24A 222-1A 221-1A 222-1A 221-1A 222-1A
[for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves
w: SY5000-221-1A
(20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)] (30 pcs.)] (30 pcs.)]
e: SY7000-221-1A
<Hexagon socket head cap screw> SUP stop valve
A q: SY3000-222-1A spacer assembly
w: SY5000-222-1A B with residual
B e: SY7000-221-1A pressure
release valve SY30M-56-2A SY50M-56-2A SY70M-56-2A
q: SY30M-56-2A
(2 pcs.) (2 pcs.) (3 pcs.)
C w: SY50M-56-2A Individual
e: SY70M-56-2A SUP (EXH)
C
spacer
assembly

A Valve
<Round head combination screw>
q: SY3000-23-33A
w: SY5000-221-5A Double check
A e: SY7000-221-5A spacer assembly SY3000- SY5000- SY7000-
B with residual 23-33A — 221-5A — 221-5A —
B pressure release (2 pcs.) (2 pcs.) (3 pcs.)
valve
C Individual
SUP (EXH)
C
spacer
assembly

A Valve
<Round head combination screw>
q: SY3000-23-32A
w: SY5000-221-3A
A Individual
e: SY7000-221-3A SY3000- SY5000- SY7000-
SUP (EXH)
B 23-32A — 221-3A — 221-3A —
B spacer
(2 pcs.) (2 pcs.) (3 pcs.)
assembly

C Individual
EXH (SUP)
C
spacer
assembly

SY3000- SY3000- SY5000- SY5000- SY7000- SY7000-


A Valve 23-24A 222-1A 221-1A 222-1A 221-1A 222-1A
<Round head combination screw> [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves
(20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)] (30 pcs.)] (30 pcs.)]
q: SY3000-23-24A
w: SY5000-221-1A SUP stop valve
e: SY7000-221-1A spacer assembly
<Hexagon socket head cap screw> B with residual
A q: SY3000-222-1A pressure
w: SY5000-222-1A release valve
B e: SY7000-222-1A
Individual
C SUP (EXH) SY30M-56-4A SY50M-56-4A SY70M-56-4A
C
q: SY30M-56-4A spacer (2 pcs.) (2 pcs.) (3 pcs.)
D assembly
w: SY50M-56-4A
e: SY70M-56-4A
Individual
EXH (SUP)
D
spacer
assembly

∗ Mounting onto a manifold follows the order explained above.


∗ The fitting for individual SUP/EXH spacers comes in a straight type only, since an elbow type would interfere with each spacer assembly when laminated.

232
SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options: Spacer Combinations and Screw List w M3: 0.8 N·m (SY5000/7000)

q
q SY3000 (M2) w
w SY5000 (M3) e
e SY7000 (M3)
Combination
Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw

<Round head combination screw> SY3000- SY3000- SY5000- SY5000- SY7000- SY7000-
q: SY3000-23-24A A Valve 23-24A 222-1A 221-1A 222-1A 221-1A 222-1A
w: SY5000-221-1A [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves
e: SY7000-221-1A (20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)] (30 pcs.)] (30 pcs.)]
<Hexagon socket head cap screw> SUP stop valve
q: SY3000-222-1A spacer assembly
A
w: SY5000-222-1A B with residual
e: SY7000-222-1A pressure
B
release valve SY30M-56-3A SY50M-56-3A SY70M-56-3A
q: SY30M-56-3A Double check (2 pcs.) (2 pcs.) (3 pcs.)
C w: SY50M-56-3A spacer
e: SY70M-56-3A C assembly with
residual pressure
release valve

SY3000- SY3000- SY5000- SY5000- SY7000- SY7000-


23-24A 222-1A 221-1A 222-1A 221-1A 222-1A
<Round head combination screw> A Valve
[for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves
q: SY3000-23-24A (20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)] (30 pcs.)] (30 pcs.)]
w: SY5000-221-1A
e: SY7000-221-1A SUP stop valve
spacer assembly
<Hexagon socket head cap screw>
q: SY3000-222-1A B with residual
A w: SY5000-222-1A pressure
e: SY7000-222-1A release valve
B Double check
q: SY30M-56-5A spacer assembly
C SY30M-56-5A SY50M-56-5A SY70M-56-5A
w: SY50M-56-5A C with residual
(2 pcs.) (2 pcs.) (3 pcs.)
pressure release
e: SY70M-56-5A
D valve

Individual
EXH (SUP)
D
spacer
assembly

A Valve
<Round head combination screw>
q: SY3000-23-32A
A w: SY5000-221-7A
e: SY7000-221-7A SY3000- SY5000- SY7000-
Interface
B 23-32A — 221-7A — 221-7A —
B regulator
(2 pcs.) (2 pcs.) (3 pcs.)

C
Individual
SUP (EXH)
C
spacer
assembly

∗ Mounting onto a manifold follows the order explained above.


∗ The fitting for individual SUP/EXH spacers comes in a straight type only, since an elbow type would interfere with each spacer assembly when laminated.
∗ When laminating an interface regulator with other options, only the combinations in the table above are possible.

233
Manifold Options SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options ∗ Refer to pages 239 to 241 for dimensions. M3: 0.8 N·m (SY5000/7000)

 Individual SUP block assembly Mounting screw How to Order Individual SUP/EXH Block Assembly
On the circuit of the plug-in connector One-touch fitting
connection base, an individual SUP Straight type SY 3 0M 78 1 A C6
block assembly can be used to supply
air to a series of valves if a separate One-touch fitting
air supply is required, or if addition air Elbow type SY 3 0M 78 2 A L6
is required for additional air flow. Series
Individual SUP block assembly 3 SY3000
occupies 1 station. 5 SY5000
Blocking disks also supplied (2 Block type
7 SY7000
78 Individual SUP block
pieces). Can be used to block both SUP blocking disk
sides of the number of stations being assembly 79 Individual EXH block
isolated for individual air supply (as
shown in example). <Example> Individual SUP/EXH block assembly
∗ Specify the mounting position of the D side U side
2 Short elbow type (Type 12)
block as well as the position where 3 Long elbow type (Type 11)
5(EA) 5(EA)
the SUP passage is to be blocked 1(P) X X 1(P) ∗ Long elbow type is for the
3(EB) 3(EB) SY5000/7000 only.
on the manifold specification sheet.
Blocking is required for 1 or 2
positions for 1 set. (2 SUP blocking Port size (Metric/One-touch fittings)
disks to block SUP is attached to Symbol P, E port SY3000 SY5000 SY7000
individual SUP block.) L4 Ø4   —
∗ Electrical wiring is connected to a L6 Ø6   
1(P)
number of stations in the individual (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) L8 Ø8 —  
SUP block manifold. L10 Ø 10 — — 
∗ When used in M10/11/12 (mixed L12 Ø 12 — — 
mounting type), select the SY50M Port size (Inch/One-touch fittings)
type for SS5Y5 and the SY70M Symbol P, E port SY3000 SY5000 SY7000
type for SS5Y7. LN3 Ø 5/32"  — —
∗ A structure to prevent screws falling LN7 Ø 1/4"   —
out is in place on the individual SUP LN9 Ø 5/16" —  —
block, making it much harder for the LN11 Ø 3/8" — — 
mounting screws to fall out.
Port size (Metric/One-touch fittings)
 Individual EXH block assembly Mounting screw Symbol P, E port SY3000 SY5000 SY7000
On the circuit of the plug-in connector C2 Ø2  — —
connection base, individual EXH C3 Ø 3.2  — —
block assembly can be used to C4 Ø4   —
individually exhaust series of valves C6 Ø6   
when the exhaust from the valves C8 Ø8 —  
would affect a number of other C10 Ø 10 — — 
stations. C12 Ø 12 — — 
Individual EXH block assembly
Port size (Inch/One-touch fittings)
occupies 1 station.
Symbol P, E port SY3000 SY5000 SY7000
Blocking disks also supplied (4 EXH blocking disk
N1 Ø 1/8"  — —
pieces). Can be used to block both assembly
N3 Ø 5/32"   —
sides of the number of stations being
<Example> N7 Ø 1/4"   
isolated for individual exhaust. (as
D side U side N9 Ø 5/16" —  
shown in example).
5(EA) X X 5(EA) N11 Ø 3/8" — — 
∗ Specify the mounting position of the 1(P) 1(P)
X X
block as well as the position where 3(EB) 3(EB)
the EXH passage is to be blocked
on the manifold specification sheet.
Blocking is required for 1 or 2
positions for 1 set. (2 sets of EXH
blocking disks (4 pcs.) to block EXH
3(R)
is attached to individual EXH block.) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B)
∗ Electrical wiring is connected to a
number of stations in the individual
EXH block manifold.
∗ When used in M10/11/12 (mixed
mounting type), select the SY50M
type for SS5Y5 and the SY70M
type for SS5Y7.
∗ A structure to prevent screws falling
out is in place on the individual EXH
block, making it much harder for the
mounting screws to fall out.
234
SY3000/5000/7000 Series

Manifold Options
 Blanking Plate with Output
[With two mounting screws]
The blanking plate extracts the individual signal of the manifold valve.

Specifications Output Polarity

Number of outputs 2 outputs Manifold common specifications A B COM.


12 VDC, 24 VDC Positive common − − +
Load voltage
(Dependent on the rated voltage of the built-in manifold) Negative common + + −
Load current 42 mA/point (Max.) ∗ Specifications are the same as the manifold common specifications.
Enclosure Dust proof (M12 connector: IP67)
∗ For serial transmission-capable manifolds, only the 24 VDC is applicable. Without connector M12 connector With connector
(COM.)
Caution Brown (A) Blue (COM.)
2 3 (A)
Tightening torque for mounting screw (COM.)
1 4
M2: 0.16 N·m (B) (A) (B)
Black (B)
Unused

How to Order Blanking Plate with Output

SY 3 0M 150 1A
Series Cable length
3 SY3000 — 300 mm
10 1000 mm

Connector type
— 1 2
Without connector With M12 connector With connector
(For ZK2 vacuum unit)

Made to Order

∗ Refer to the specifications for output polarity.

 SUP/EXH blocking disk assembly (for connector type manifold, Type 10, 11, 12)
[SUP blocking disk]
By inserting the SUP blocking disk in the pressure supply passage of the SUP blocking EXH blocking
manifold valve, can provide two different high and low pressure in one Series
disk assembly disk assembly
manifold. SY3000 SY30M-40-1A SY30M-40-2A
[EXH blocking disk] SY5000 SY50M-40-1A SY50M-40-1A
By inserting the EXH blocking disk in the exhaust passage of the manifold valve, SY7000 SY70M-40-1A SY70M-40-1A
can separate the exhaust from the valve so it does not affect the other valves. It
can also be used for the manifold for the positive pressure and vacuum mixed
manifold. (2 pcs. are required to block FA/EB both sides of the EXH.)

 Label for blocking disk ∗ If the blocking disk assembly is ordered using
Label to indicate and confirm on the manifold where the SUP/EXH the manifold specification sheet and ordered
blocking disk assemblies were inserted. (3 sheets each) at the same time as the manifold, the position
where the blocking disk assembly is inserted
will be labelled and shipped out.

SUP/EXH blocking SUP blocking EXH blocking


disk label disk label disk label
Series Part no.
SY3000
SY5000 SJ3000-155-1A
SY7000

235
Manifold Options SY3000/5000/7000 Series

Manifold Options
 Back pressure check valve assembly (Retrofit or pre-installed type)
It prevents cylinder malfunction caused by other valve exhaust entry. Insert For SY3000
it into EA/EB port (valve mounting side) on the manifold side of a valve
which is affected. It is effective when a single-acting cylinder is used. EA port
∗ When ordering assemblies incorporated with a manifold, refer to the Ordering Example below
(when installed in all stations.) EB port
Back pressure check valve assembly
∗ When a check valve for back pressure prevention is desired and is to be
installed only in certain manifold stations, clearly indicate the part number 2 pcs. in 1 set
and specify the mounting position on the manifold specification sheet.
<Precautions>
1. The manifold installed type back pressure check valve assembly is For SY5000/7000
assembly parts with a check valve structure. However, since slight air
leakage against the back pressure is allowed due to its structure, adverse EA port
effects of the back pressure due to increase in exhaust resistance cannot
be prevented if the manifold exhaust port and other exhaust ports are put
together for piping or if the piping diameter is narrowed. As a result, this EB port
may cause the actuator and air operated equipment to malfunction. So, be
careful not to restrict the exhaust air. If the exhaust resistance becomes
large, select a built-in valve type with rubber seal. Mount the back pressure check valve
2. When the back pressure check valve assembly is mounted, please contact assemblies on the EA and EB ports in
SMC for valve flow rate characteristics. the order shown in the figure above.
Ordering Example Series Part no.
SS5Y3-10F1-05B-C6·····1 set (Type 10 5-station manifold base part no.) SY3000 SY30M-24-1A
∗SY3201-5U1·················· 5 sets (2-position double part no.)
∗SY30M-24-1A················5 sets (Back pressure check valve assembly part no.)
SY5000 SY50M-24-1A
The asterisk denotes the symbol for the assembly. SY7000 SY70M-24-1A

 Dual flow fitting (for connector connecting base, Type 10, side ported)
This is a fitting for cylinder ports which enables simultaneous actuation and increase in flow rate of
valves for 2 stations. Clip
∗ When ordering assemblies incorporated into a manifold, refer to the Ordering Example below and
specify on the manifold specification sheet.
Ordering Example Dual flow fitting

How to Order Dual Flow Fitting SS5Y3-10F1-08B-CM


∗SY3100-5U1
∗SY30M-120-1A-C8
SY 3 0M 120 1A C8 The asterisk denotes the
symbol for the assembly.
Series A, B port size (One-touch fittings)
3 SY3000 Symbol A, B port SY3000 SY5000 ∗ Specifically for side porting for a connector connecting base
5 SY5000 C8 Ø8  — Cannot be attached to bottom or top ported, or mixed mounting
Metric size types that are metal or connector connecting bases
C10 Ø 10 — 
∗ When adding or changing clips, push them into the very end of
N9 Ø 5/16"  — the manifold for each station. Also, make sure to use the clip
Inch size
N11 Ø 3/8" —  that was packed together, as the clip and the fitting for one
station differ among products that can be used with the SY5000.
∗ Not available for the SY7000 series
SY3000 SY5000 ∗ Refer to the table below to see which spacers are applicable.
(22.8) (24.1)
Series
Each type of spacer
SY3000 SY5000
Individual SUP (EXH) spacer assembly ҂ 
҂ 
13.6

SUP stop valve spacer assembly with residual pressure release valve
11.1

32.1

҂ 
26.3

Double check spacer assembly with residual pressure release valve


Interface regulator ҂ ҂
: Can be built in ҂: Cannot be built in

 Silencer A
C
(One-touch fitting connection type)
This silencer can be mounted to the 3/5 Series Model Effective area A B C
ØB
Ød

(E: EXH) port of the manifold in one step. For SY3000 (Ø 8) AN15-C08 20 mm2 45 13 20
For SY5000 (Ø 10) AN20-C10 30 mm2 57.5 16.5 30.5
Body Sound absorbing material For SY7000 (Ø 12) AN30-C12 41 mm2 71.5 20 43.5
∗ Shipped together with the product (Resin) (Resin sintered body)

 Plug Dimensions
These are inserted in unused cylinder Applicable fitting size Applicable fitting size
Ø d (Metric size)
Model A L ØD Ø d (Inch size)
Model A L ØD
ports and P, E ports.
Ød

2 KJP-02 8.2 17 3 1/8" KQ2P-01 16 31.5 5


3.2 KQ2P-23 16 31.5 5 5/32" KQ2P-03 16 32 6
ØD

4 KQ2P-04 16 32 6 1/4" KQ2P-07 18 35 8.5


6 KQ2P-06 18 35 8 5/16" KQ2P-09 20.5 39 10
A 8 KQ2P-08 20.5 39 10 3/8" KQ2P-11 22 43 11.5
L 10 KQ2P-10 22 43 12 1/2" KQ2P-13 24 46 15
∗ Shipped together with the product 12 KQ2P-12 24 45.5 14
236
SY3000/5000/7000 Series

Manifold Options A transparent plastic plate to put a label with the name of the function of the solenoid valve

 Name plate (For connector connecting base)

SY3000: For SS5Y3-10 (Side ported)


SY5000: For SS5Y5-10/11 (Side/Bottom ported)
SY7000: For SS5Y7-(M)10/11 (Side/Bottom ported)
SS5Y3- 10
Name plate bracket assembly and name plate mounting instructions
Insert it into the groove on the name plate bracket onto which a SS5Y5- 10
11
SUP/EXH (end) block is mounted, as shown in Figure 2.
∗ When ordering assemblies incorporated with a manifold, refer to the SS5Y7-(M) 10
11
Ordering Example below.

Mounting and Option


Mounting option
Symbol Printing DIN rail Direct
Yes No With Without Specified length mounting
AA  — — — — 
A  —  — — —
A0  — —  — —
A3  — — — For 3 stations —



A24  — — — For 24 stations —
BA —  — — — 
B —   — — —
B0 —  —  — —
B3 —  — — For 3 stations —



B24 —  — — For 24 stations —
Ordering Example ∗ Name plates cannot be mounted onto Type 1 2 (Top ported) and Type
SS5Y3-10F1-05UR-C6AA ······································· 1 set 10 (Side ported) mixed mounting types with top ported valves, nor onto
∗SY3200R-5U1·························································· 5 sets manifolds with optional laminated spacers.
∗ No name plate settings are available for the SY 3 0 0 0 /SY 5 0 0 0 mixed
The asterisk denotes the symbol for the assembly. mounting types. However, they are available for the SY 5 0 0 0 /SY 7 0 0 0
mixed mounting types.

<SY3000> <SY5000/7000>
n = 1 to 3 n = 4 to 24 n = 1 to 3 n = 4 to 24
42.3

62.5

3 1 2 3 4 5 n: Number
of stations
1 3 1 2 3 4 5 n: Number
Pitch of stations
Pitch
10.5
P = 16 (SY5000)
P = 19 (SY7000)
Make sure to mount
Make sure to mount
in the right direction. (20°)
in the right direction.
SY5000: SY50M-86-(N)
Tightening torque for mounting screw (M3): 0.8 N·m Tightening torque for mounting screw (M3): 0.8 N·m SY7000: SY70M-86-(N)
SY30M-86-(N) Name plate
Mounting screw Name plate Mounting screw  is the number of stations (1 to 24).
Name plate bracket Name plate bracket
(M3)  is the number of stations (1 to 24). (M3)
SY30M-85-1A
Name plate bracket assembly
(Supplied individually) SY50M-85-1A
Align this line along (For SY5000 only) Align this line along
Name plate insertion hole the end of the Name plate bracket assembly the end of the
Port block 2-position valve. (Supplied individually) 2-position valve.

Valve end Valve end


SUP/EXH end block SUP/EXH
(External pilot type) end block

SUP/EXH
SUP/EXH block
Figure 1 Figure 2
block
Figure 1 Figure 2
Insertion hole

237
Manifold Options SY3000/5000/7000 Series

Manifold Options
∗ A transparent plastic plate to put a label with the name of the function of the solenoid valve

 If adding a name plate


If adding a name plate to a manifold in use, order a name plate bracket assembly, in addition to ordering a name plate.
Refer to the table below for the part number and the amount.

Name plate part number


Model SS5Y3-10 SS5Y5-10/11 SS5Y7-(M)10/11 Note
Name Printed SY30M-86-N SY50M-86-N SY70M-86-N :Number of stations
plate No printing SY30M-86- SY50M-86- SY70M-86- (1 to 24)

Name plate bracket assembly part number and number of items ordered
Model SS5Y3-10 SS5Y5-10/11
Name plate assembly part number SY30M-85-1A SY50M-85-1A
Internal pilot
2 pcs.
Manifold SUP/EXH U/D piping
block assembly Internal pilot
2 pcs.
double sided piping Caution
Pilot type 2 pcs.
External pilot
and 1 pc.∗1 1. Be sure to shut off the power and air supplies before
U/D piping
P, E port entry mounting the name plate bracket assembly.
External pilot
Not required∗1 Furthermore, since air may remain inside the
double sided piping
actuator, piping, and manifold, confirm that the air is
∗1 If the manifold is an external pilot, an insertion slot for name plates is on the port block completely exhausted before performing any work.
of the SUP/EXH block assembly. Thus, a bracket assembly is no longer required on the 2. When disassembly and assembly are performed, air
port piping side. leakage may result if the tightening of the bracket
∗ Name plate bracket assembly is not required for the SY7000. mounting screws is inadequate.

238
SY3000/5000/7000 Series

Dimensions: Manifold Options/SY3000 Series


 Blanking plate  Individual SUP/EXH spacer  Double check spacer assembly with  Individual SUP/EXH block
assembly assembly (Top ported) residual pressure release valve assembly (Top ported)

C6: 92.3
N7: 96.1

LN7: 72.3
63.1

84.1
LN7: 63.8

L6: 69.8
L6: 61.3
92.6

92.6
92.6

101.2

92.6
101.2
111.6

112.8
3.6

14

3.6
<Type 10, 12>
One-touch fitting
(SUP port, EXH port) One-touch fitting
<Type 10>
Applicable tubing O.D.: Ø 4, Ø 5/32" (SUP port, EXH port)
: Ø 6, Ø 1/4" Applicable tubing O.D.: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"

<Type 12> <Type 12>

 Individual SUP/EXH spacer  SUP stop valve spacer assembly with  Interface regulator  Individual SUP/EXH block
assembly (Side ported) residual pressure release valve assembly (Side ported)

One-touch fitting One-touch fitting


(SUP port, EXH port) (SUP port, EXH port)
Applicable tubing O.D.: Ø 2 Applicable tubing O.D.: Ø 2
: Ø 3.2, Ø 1/8"
78.1
77.4

: Ø 3.2, Ø 1/8
: Ø 4, Ø 5/32"
62.6

: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
40.4

: Ø 6, Ø 1/4"
78.1

48
78.1

(59.2)
39.5

(100.7)
92.2
92.6

103.2
(111.7)
109.8
(118.3)
92.6
101.2
92.6

92.6
Max. 14
(2)

<Type 10, 12> <Type 10>


<Type 10> <Type 10, 12>
∗ The dimensions within ( ) apply to ∗ The dimensions within ( ) apply to
the SY30M-50-1AE. the SY30M---3.

239
Manifold Options SY3000/5000/7000 Series

Dimensions: Manifold Options/SY5000 Series


 Blanking plate  Individual SUP/EXH spacer  Double check spacer assembly with  Individual SUP/EXH block  Individual SUP/EXH block
assembly assembly (Top/Bottom ported) residual pressure release valve assembly (Top ported) assembly (Side ported)

One-touch fitting
(SUP port, EXH port)
Applicable tubing O.D.: Ø 4, Ø 5/32"

(108.8)

101.2
: Ø 6, Ø 1/4"

(88.9)
(76.8)
: Ø 8, Ø 5/16"
73.2

63.7
113.4
113.4

116.7

113.4
126.5

113.4
142.5

138.7

126.7

113.4
5.5

18.2

5.7
<Type 10, 11, 12> <Type 10, 11>
One-touch fitting One-touch fitting
(SUP port, EXH port) (SUP port, EXH port)
Applicable tubing O.D.: Ø 4
Applicable tubing O.D.: Ø 4,
: Ø 6, Ø 1/4"
: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
: Ø 8, Ø 5/16"

<Type 11, 12> <Type 12> <Type 10>

 Individual SUP/EXH spacer  SUP stop valve spacer assembly with  Interface regulator  Individual SUP/EXH block
assembly (Side ported) residual pressure release valve assembly (Side ported)

One-touch fitting One-touch fitting


(SUP port, EXH port) (SUP port, EXH port)
Applicable tubing O.D.: Ø 4, Ø 5/32" Applicable tubing O.D.: Ø 4,
: Ø 6, Ø 1/4" : Ø 6, Ø 1/4"
90.7
(78.2)

: Ø 8, Ø 5/16" : Ø 8, Ø 5/16"
96.2
92.4
79.1
54.6
90.7

(38.5)
51.6

113.4
113.4

127.6
127.9

145.6

113.4
113.4

142.7
(3)

Max. 21

<Type 10, 11, 12>


21.7

∗ The dimensions within ( ) apply


to the SY50M-50-1AE.
<Type 10> <Type 10, 11, 12> <Type 11>

240
SY3000/5000/7000 Series

Dimensions: Manifold Options/SY7000 Series


 Blanking plate  Individual SUP/EXH spacer assembly  Double check spacer assembly with  Individual SUP/EXH block
assembly (Top/Bottom ported) residual pressure release valve assembly (Top ported)

(121.1)

114.9

(95.2)
(83.2)
80.1

128.8

128.8
133.2

128.8
128.8

145.1

145.1
164.1

167.1
21.7
7.1

7.1
One-touch fitting One-touch fitting
<Type 10, 11, 12> (SUP port, EXH port) (SUP port, EXH port)
Applicable tubing O.D.: Ø 6, Ø 3/8" <Type 10, 11> Applicable tubing O.D.: Ø 6, Ø 3/8"
:Ø8 :Ø8
: Ø 10 : Ø 10
: Ø 12 <Type 12> : Ø 12
<Type 11, 12>

 Individual SUP/EXH spacer  SUP stop valve spacer assembly with  Individual SUP/EXH block
assembly (Side ported) residual pressure release valve assembly (Side ported)

One-touch fitting
One-touch fitting
(SUP port, EXH port)
(SUP port, EXH port) Applicable tubing O.D.: Ø 6, Ø 3/8"
Applicable tubing O.D.: Ø 6, Ø 1/4" :Ø8
100.9

: Ø 8, Ø 5/16"
(86.8)

: Ø 10
: Ø 10, Ø 3/8"
: Ø 12
: Ø 12
100.9

68.8
56.8

128.8
148.7

(For Ø 12)
(126.3)
(For Ø 12)
(126.3)

(138.2)
(138.2)

(2)

<Type 10, 11, 12>

∗ The dimensions within ( ) apply to


the SY70M-50-1AE.
<Type 10> <Type 10>

241
Manifold Options SY3000/5000/7000 Series

Dimensions: Manifold Options/SY7000 Series


 Interface regulator  Individual SUP/EXH block assembly (Bottom ported)

103.1

(42.4)
96.1
82.8
58.3
One-touch fitting
(SUP port, EXH port)
Applicable tubing O.D.: Ø 8, Ø 3/8"
: Ø 10
: Ø 12
128.8
143.8

154.9
161.8

164.1
Max. 21

<Type 11>
<Type 10, 11, 12>

242
243
Plug-in Metal Base

Side ported

Bottom ported

Top ported

244
SY3000/5000/7000 Series Type 50, 51, 52
Plug-in Metal Base

Manifold Specifications

D-sub connector Flat ribbon cable Serial wiring


Model S5 type
F type P type PG type PH type
(EX510)
Manifold type Plug-in metal base
SUP/EXH port type Common SUP/EXH
All double wiring 2 to 9 stations 2 to 4 stations 2 to 8 stations
Valve stations 2 to 12 stations
All single wiring 2 to 12 stations 2 to 8 stations 2 to 12 stations
Flat ribbon cable connector
D-sub connector with strain relief
Conforming to Conforming to MIL-C-83503
Applicable connector —
MIL-C-24308
JIS-X-5101 Socket: 26 pins Socket: 20 pins Socket: 10 pins
MIL type MIL type MIL type
Internal wiring Positive common, Negative common
SY3000 1/8
1(P), 3/5(E) port SY5000 1/4
SY7000 3/8

M5 x 0.8, 1/8
SY3000 Ø 2 One-touch fitting, Ø 3.2 One-touch fitting, Ø 4 One-touch fitting, Ø 6 One-touch fitting
Ø 1/8" One-touch fitting, Ø 5/32" One-touch fitting, Ø 1/4" One-touch fitting
Port size
1/8, 1/4
4(A), 2(B) port SY5000 Ø 4 One-touch fitting, Ø 6 One-touch fitting, Ø 8 One-touch fitting
Ø 5/32" One-touch fitting, Ø 1/4" One-touch fitting, Ø 5/16" One-touch fitting

1/4
SY7000 Ø 6 One-touch fitting, Ø 8 One-touch fitting, Ø 10 One-touch fitting, Ø 12 One-touch fitting
Ø 1/4" One-touch fitting, Ø 5/16" One-touch fitting, Ø 3/8" One-touch fitting

Enclosure (Based on IEC60529) IP40 IP20

245
Type 50, 51, 52
Plug-in Metal Base SY3000/5000/7000 Series

Manifold Flow Rate Characteristics∗1/Manifold Weight


Valve Seal Type: Rubber Seal
Port size Valve flow rate characteristics Weight: W [g]∗2
Model 1, 5, 3 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→E) (n: stations)
(P, EA, EB) (A, B) C [dm3/(s·bar)] b Q [l/min (ANR)]∗3 C [dm3/(s·bar)] b Q [l/min (ANR)]∗3 Fixed: C Replaceable:: KC
SS5Y3-50 (Side ported) 1/8 C6 1.1 0.19 262 1.1 0.15 256 39n + 247 43.5n + 247
SS5Y3-51 (Bottom ported) 1/8 C6 1.2 0.31 307 1.2 0.14 278 41.5n + 251 48.5n + 251
SS5Y3-52 (Top ported) 1/8 C6 1.1 0.29 278 1.2 0.20 287 44n + 247
SS5Y5-50 (Side ported) 1/4 C8 2.6 0.28 653 2.6 0.14 603 93n + 379 110n + 379
SS5Y5-51 (Bottom ported) 1/4 C8 2.7 0.35 709 2.8 0.20 671 93n + 413 113n + 413
SS5Y5-52 (Top ported) 1/4 C8 2.6 0.26 645 3.1 0.13 715 103n + 379
SS5Y7-50 (Side ported) 3/8 C10 3.8 0.27 948 4.0 0.20 958 144n + 510 158n + 510
SS5Y7-51 (Bottom ported) 3/8 C10 4.1 0.34 1070 4.8 0.20 1150 150n + 549 172n + 549
SS5Y7-52 (Top ported) 3/8 C10 4.5 0.27 1123 4.9 0.24 1201 164n + 510

Valve Seal Type: Metal Seal


Port size Valve flow rate characteristics Weight: W [g]∗2
Model 1, 5, 3 4, 2 1→4/2 (P→A/B) 4/2→5/3 (A/B→E) (n: stations)
(P, EA, EB) (A, B) C [dm3/(s·bar)] b Q [l/min (ANR)]∗3 C [dm3/(s·bar)] b Q [l/min (ANR)]∗3 Fixed: C Replaceable:: KC
SS5Y3-50 (Side ported) 1/8 C6 0.9 0.14 209 1.0 0.12 229 39n + 247 43.5n + 247
SS5Y3-51 (Bottom ported) 1/8 C6 1.0 0.21 241 1.1 0.10 250 41.5n + 251 48.5n + 251
SS5Y3-52 (Top ported) 1/8 C6 1.1 0.15 256 1.1 0.14 255 44n + 247
SS5Y5-50 (Side ported) 1/4 C8 2.2 0.20 527 2.3 0.13 530 93n + 379 110n + 379
SS5Y5-51 (Bottom ported) 1/4 C8 2.4 0.26 595 2.5 0.16 586 93n + 413 113n + 413
SS5Y5-52 (Top ported) 1/4 C8 2.4 0.18 568 2.6 0.12 596 103n + 379
SS5Y7-50 (Side ported) 3/8 C10 3.2 0.23 780 3.5 0.18 829 144n + 510 158n + 510
SS5Y7-51 (Bottom ported) 3/8 C10 3.5 0.25 863 4.0 0.16 937 150n + 549 172n + 549
SS5Y7-52 (Top ported) 3/8 C10 3.5 0.21 843 3.8 0.18 900 164n + 510
∗1 The value is for manifold base with 5 stations and individually operated 2-position type.
∗2 Weight: W is the value for the D-sub connector manifold.
To obtain the weight with valves attached, add the valve weights given on page 19 for the appropriate number of stations.
∗3 These values have been calculated according to ISO6358 and indicate the flow rate under standard conditions with an
inlet pressure of 0.6 MPa (relative pressure) and a pressure drop of 0.1 MPa.
∗ Calculation of effective area S and sonic conductance C: S = 5.0 x C

246
Plug-in Metal Base
Type 50
Side Ported D-sub Connector Flat Ribbon Cable

SY3000/5000/7000 Series
Type 51
Bottom Ported

RoHS
How to Order Manifolds

SS5Y 3 50 F 1 05 D C6
q w e r t y u i o !0
q Series w Type e Connector type
3 SY3000 50 Side ported F: D-sub connector P: Flat ribbon cable
5 SY5000 51 Bottom ported (25 pins) (26 pins)
7 SY7000 50R Side ported, External pilot
∗ External pilot is not available
for the bottom-ported type.

r Connector entry direction


1: Upward 2: Lateral PG: Flat ribbon cable PH: Flat ribbon cable
(20 pins) (10 pins)

t Wiring type
— All double wiring∗1
S All single wiring∗2
How to Order Manifold Assembly ∗1 All double wiring: 2-position single, double, 3-position, and 4-position
valves can be used on all manifold stations.
∗2 All single wiring: Available only for the manifold which has 2-position
Example (SS5Y3-50F2-) single for all stations
2-position double (24 VDC) Note that 2-position double, 3-, or 4-position valves cannot be used.
2-position single (24 VDC)
SY3100-5U1 (3 sets)
SY3200-5U1 (1 set) ∗ If a mix of single and double wiring is required, it is supplied as a
3-position closed special order.
centre (24 VDC)
SY3300-5U1 (1 set)

y Valve stations
F: D-sub connector (25 pins) P: Flat ribbon cable (26 pins)
Symbol Stations Note Symbol Stations Note
ide 02 2 stations All 02 2 stations All
Us

double double
s
n

wiring wiring
tio

12 12 stations 12 12 stations
ta
S

Manifold base 02 2 stations All 02 2 stations All


3

(5 stations)

single single
2

SS5Y3-50F2-05D-C6
1

ide 12 12 stations wiring 12 12 stations wiring


Ds
PG: Flat ribbon cable (20 pins) PH: Flat ribbon cable (10 pins)
SS5Y3-50F2-05D-C6 ··· 1 set (Type 50 5-station manifold base part no.) Symbol Stations Note Symbol Stations Note
∗SY3100-5U1 ················· 3 sets (2-position single part no.) 02 2 stations All 02 2 stations All
∗SY3200-5U1 ················· 1 set (2-position double part no.)

double double
∗SY3300-5U1 ················· 1 set (3-position closed centre part no.) wiring wiring
09 9 stations 04 4 stations
The asterisk denotes the symbol for the assembly. 02 2 stations All 02 2 stations All
Prefix it to the part numbers of the valve, etc.

single single
• For the valve arrangement, the valve closest to the D side is considered the 1st station. 12 12 stations wiring 08 8 stations wiring
• Under the manifold part number, state the valves to be mounted in order starting
∗ This also includes the number of the blanking plate assembly.
with the 1st station as shown in the figure above. If the arrangement becomes too
complicated, specify the details on a manifold specification sheet.
∗ When mixing top-ported configurations, select from those listed on page 268.
In such cases, use caution as there is also output on the A and B ports on the base side.
Specify on the manifold specification sheet if plugs are required for the A and B ports on
the base side.
247
Plug-in Metal Base SY3000/5000/7000 Series

u P, E port entry i A, B port size


U U side∗1 Thread piping
D D side∗1∗2 Symbol A, B port SY3000 SY5000 SY7000
B Both sides M5 M5 x 0.8  — —
∗1 Plugs are mounted on the opposite 01 1/8   —
side of the selected ports. 02 1/4 —  
∗2 Only D side is available for the type 51
bottom-ported type. One-touch fitting (Metric)
Symbol A, B port SY3000 SY5000 SY7000
o Thread type C2 Ø2  — —

— Rc C3 Ø 3.2  — —
 
Fixed

F G C4 Ø4 —
N NPT C6 Ø6   —
T NPTF C8 Ø8 —  
C10 Ø 10 — — 
!0 Mounting KC2 Ø2  — — Type 50 Type 51
— Direct mounting KC3 Ø 3.2  — — (Side ported) (Bottom ported)
D DIN rail mounting (With DIN rail) KC4  
Replaceable

Ø4 —
D0 DIN rail mounting (Without DIN rail)
KC6 Ø6   
D3 For 3 stations Specify a length longer
KC8 Ø8 —  

than that of the standard


D12 For 12 stations rail. KC10 Ø 10 — — 
∗ Only direct mounting is available for the type KC12 Ø 12 — — 
51 bottom-ported type.
M∗1 Mixed sizes   
∗ Refer to page 319 for the fixation of DIN rail
mounting type manifold. P, E port size (Thread piping) 1/8 1/4 3/8

One-touch fitting (Inch)


Symbol A, B port SY3000 SY5000 SY7000
N1 Ø 1/8"  — —
N3 Ø 5/32"   —
Fixed

N7 Ø 1/4"   —
N9 Ø 5/16" —  
N11 Ø 3/8" — — 
KN1 Ø 1/8"  — — Type 50 Type 51
KN3   (Side ported) (Bottom ported)
Replaceable

Ø 5/32" —
KN7 Ø 1/4"   
KN9 Ø 5/16" —  
KN11 Ø 3/8" — — 
M∗1 Mixed sizes   
P, E port size (Thread piping) 1/8 1/4 3/8
∗1 When ports are of mixed sizes, indicate the piping specifications on the
manifold specification sheet.

Protective class
class # (Mark: )
248
SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted

q Series y Pilot valve option !0 Manual override


3 SY3000 — Standard (0.7 MPa) —: D:
5 SY5000 B Quick response type (0.7 MPa) Non-locking Push-turn
7 SY7000 K∗1 High pressure type (1.0 MPa) push type locking
∗1 Only the metal seal type is available for the slotted type
high pressure type.
w Type of actuation
1
2-position
Single u Coil type
2 Double — Standard E: F:
3 Closed centre T With power saving circuit (Continuous duty type) Push-turn Slide locking
4 3-position Exhaust centre
∗ Be sure to select the power saving circuit
locking lever type
5 Pressure centre type
type if the valve is to be continuously
A∗1 N.C./N.C. energised for long periods of time.
4-position
B∗1 N.O./N.O. ∗ Be careful of the energising time when the
dual 3-port
C∗1 N.C./N.O. power saving circuit is selected. Refer to page
316 for details.
∗1 Only the rubber seal type is available for the
4-position dual 3-port valve. ∗ Refer to page 36 for the safety slide locking
manual override.
i Rated voltage
5 24 VDC
e Seal type 6 12 VDC
!1 Type of mounting screw
0 Rubber seal
— Round head combination screw
1 Metal seal
B Hexagon socket head cap screw
o Light/surge voltage suppressor K Round head combination screw (Drop prevention type)
and common specification H Hexagon socket head cap screw (Drop prevention type)
r Pilot type Surge voltage Common ∗ For “K” and “H,” the valve body cover has a
— Internal pilot Symbol With light drop prevention construction to stop the
suppressor specification
R External pilot mounting screws from falling out when the
— — —
valve is removed for maintenance, etc.
R — Non-polar ∗ When ordering a valve individually, the
U  base gasket is not included.
t Back pressure check valve S —

Positive Since the base gasket is attached to the
(Built-in valve type) Z  common manifold, please order the base gasket
NS — Negative separately if it is needed for maintenance.
— None Refer to page 290 for base gasket and
H Built-in NZ  common
mounting screw part numbers.
∗ Only the rubber seal type is available. ∗ For the non-polar type, be careful of surge ∗ “B” and “H” cannot be selected for the
∗ The back pressure check valve is not available voltage intrusion. Refer to page 317 for details. individual SUP/EXH spacer assembly,
for the 3-position type or the SY7000. ∗ Only “Z” and “NZ” types are available with a interface regulator, or double check spacer
power saving circuit. assembly with residual pressure release
valve.

Protective class
class # (Mark: )
249
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 50/Side Ported

Dimensions: SY3000 Series Metal Base D-sub Connector

U M5
C, N (D)
SS5Y3-50(R)F 12 - Stations D - KC, KN B
6.1 (Station 1)---(Station n)

50RF 12 - Stations UD

manual override)
(Slide locking
(68.7)

68.3
62.6
54.6

2B 2B 3
[Plug for external pilot]

7.1

32
22.6
4A 4A 2B

4A

(For DIN rail


mounting)
7.5
C2, C3: 5.4

11.8
C4, C6: 6.6
C2, C3: 42.4
∗ The above drawing shows when P,
(Pitch)
C4, C6: 41.8 P = 10.5 E port entry is D.
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 2
: Ø 3.2, Ø 1/8"
D side L3 U side : Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
5.3 L4
(Connector entry
(DIN rail mounting hole pitch: 12.5)
Manual override upward direction)
(Pitch)
DIN rail holding screw
(For DIN rail mounting)
45.1 P = 10.5 (
Push-turn locking slotted type:
Press, then rotate it. )
Applicable connector: D-sub
JIS-X-5101
MIL-C-24308
equivalent ( )
14 24.1 4(A) port side : Blue (For rubber seal)
Light/surge : Grey (For metal seal)
DIN rail bracket mounting screw M5 x 0.8 (External pilot)
(8) voltage 2(B) port side : Yellow
(For DIN rail mounting) suppressor [Pilot EXH port]

DIN rail

B A B A B A B A B A
92.7
89

5EA

PE
14 A 14 A 14 A 14 A 14 A
16.8 17.2
15.9 16.2
79
5.5

64.4
35

56.9
21.8 16

1P
32.5

29.8
26.6

X
12 B 12 B 12 B 12 B 12 B

3EB

4 x Ø 4.5 2 x M2.6
L2 8 8.6
)

(For mounting) 4
Replaceable: 7.7

2 x 4-40 UNC
(L5) 14.5 [For inch size thread]
L1
22.1
Fixed: 4.1

M5 x 0.8 (External pilot)


28 [External pilot port]
1/8
∗: These figures show the “SS5Y3-50F2-05B-C6”.
(

[1(P), 5(EA), 3(EB) port]

Port size M5 One-touch fitting (Replaceable)

2B 2B
7.1

7.1
32

32
22.6

22.6

4A 4A

M5 x 0.8
6.6 (Pitch)
[4(A), 2(B) port] P = 10.5
(Pitch) 48.4
41.8 P = 10.5
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 2
: Ø 3.2, Ø 1/8"
: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17

250
SY3000/5000/7000 Series
Plug-in Type 50/Side Ported

Dimensions: SY3000 Series Metal Base D-sub Connector

U
SS5Y3-50(R)F 21 - Stations D -01(D)
B

(Station 1)------(Station n)
6.1
50RF 12 - Stations UD

manual override)
(Slide locking
(68.7)

68.3
62.6
54.6

2B 2B
[Plug for external pilot]
2B

7.1

32
22.6
4A 4A
4A

(For DIN rail


mounting)
6.6

7.5
(Pitch)

11.8
41.8 P = 12.5 1/8 ∗ The above drawing shows when P,
[4(A), 2(B) port] E port entry is D.

D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5)
Manual override
DIN rail holding screw 45.1
(Pitch)
P = 12.5 (
Push-turn locking slotted type:
Press, then rotate it. ) Applicable connector: D-sub (JIS-X-5101
MIL-C-24308 )
equivalent
(For DIN rail mounting)
14 24.1 4(A) port side : Blue (For rubber seal)
Light/surge M5 x 0.8 (External pilot)
4 x Ø 4.5 (8) : Grey (For metal seal)
voltage [Pilot EXH port]
suppressor 2(B) port side : Yellow
(For mounting)
DIN rail

B A B A B A B A B A
(Connector entry
92.7

upward direction)
89

5EA
14 A 14 A 14 A 14 A 14 A

PE
16.8 17.2
15.9 16.2
79
5.5

64.4
35

56.9
21.8 16

1P
32,5

29.8
26.6

X
12 B 12 B 12 B 12 B 12 B
3EB

8.6 2 x M2.6
4 L2 8
2 x 4-40 UNC
14.5
(L5) L1 [For inch size thread]
22.1
DIN rail bracket mounting screw 28
(For DIN rail mounting)

1/8
[1(P), 5(EA), 3(EB) port]

∗: These figures show the “SS5Y3-50F2-05B-01”. M5 x 0.8 (External pilot)


[External pilot port]

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5
L4 100 112.5 125 137.5 150 162.5 175 187.5 200 212.5 225
L5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5

251
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 50/Side Ported

Dimensions: SY5000 Series Metal Base D-sub Connector

U 01
C, N (D)
SS5Y5-50(R)F 12 - Stations D - KC One-touch fitting
, KN B
[4(A), 2(B) port]
Applicable tube O.D.: Ø 4, Ø 5/32"
6.1 (Station 1)----------- (Station n) : Ø 6, Ø 1/4"
50RF 12 - Stations UD
: Ø 8, Ø 5/16"

manual override)
(Slide locking
3
[Plug for external pilot]
(74.7)

74.3
68.6
2B
60.6

2B 2B

7.8

38
27.3
4A 4A
4A

10
∗ The above drawing shows when P,

(For DIN rail


mounting)
8.4 (Pitch)
E port entry is D.

14.3
45.8 P = 16

D side U side
L3
5.3 L4 Manual override

DIN rail holding screw


(DIN rail mounting hole pitch: 12.5)
(Pitch) (
Push-turn locking slotted type:
Press, then rotate it. ) Applicable connector: D-sub (JIS-X-5101
MIL-C-24308 )
equivalent

(For DIN rail mounting) 50 P = 16 Light/surge 4(A) port side : Blue (For rubber seal)
16 24.1 voltage : Grey (For metal seal) M5 x 0.8 (External pilot)
4 x Ø 4.5 suppressor 2(B) port side : Yellow [Pilot EXH port]
(8)
(For mounting)

DIN rail

B A B A B A B A B A (Connector entry
14 A 14 A 14 A 14 A 14 A

PE
5EA
106.2

upward direction)
5.5

23.2
116.6

96.2
35

20
81.6
74.1
20

1P
24.6
20
49.4

43.8

40.2

3EB
30.2

X
12 B 12 B 12 B 12 B 12 B

L2 12.3
)

5 2 x M2.6
Replaceable: 8.5

(L5) L1 18 2 x 4-40 UNC


[For inch size thread]
Fixed: 4.9

28
34
DIN rail bracket mounting screw
(For DIN rail mounting) 1/4
(

[1(P), 5(EA), 3(EB) port]


M5 x 0.8 (External pilot)
∗: These figures show the “SS5Y5-50F2-05B-C8”. [External pilot port]

Port size 01 One-touch fitting (Replaceable)

2B 2B
9.8
7.8

38

38
27.3

27.3

4A 4A

8.4 (Pitch)
(Pitch)
51.6 P = 16
45.8 P = 16
One-touch fitting
1/8 [4(A), 2(B) port]
[4(A), 2(B) port] Applicable tube O.D.: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5

252
SY3000/5000/7000 Series
Plug-in Type 50/Side Ported

Dimensions: SY5000 Series Metal Base D-sub Connector

U
SS5Y5-50(R)F 21 - Stations D -02(D)
B

6.1 (Station 1) ------------- (Station n)


50RF 12 - Stations UD

manual override)
(Slide locking
3
(74.7)

74.3
[Plug for external pilot]

68.6
60.6

2B 2B
2B

9.8

38
27.3
4A 4A
4A

10

(For DIN rail


mounting)
8.4 1/4
(Pitch) ∗ The above drawing shows when P,

14.3
45.8 P = 17.5 [4(A), 2(B) port] E port entry is D.

D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent
DIN rail holding screw
(For DIN rail mounting) 50
(Pitch)
P = 17.5
(
Push-turn locking slotted type:
Press, then rotate it. )
Light/surge 4(A) port side : Blue (For rubber seal) M5 x 0.8 (External pilot)
4 x Ø 4.5 16 24.1 voltage : Grey (For metal seal) [Pilot EXH port]
suppressor 2(B) port side : Yellow
(For mounting)

DIN rail

B A B A B A B A B A (Connector entry
upward direction)

PE
14 A 14 A 14 A 14 A 14 A

5EA
106.2
5.5

23.2
116.6

96.2
35

20
81.6
74.1
20

1P
24.6
20
49.4

43.8

40.2

3EB
30.2

X
12 B 12 B 12 B 12 B 12 B 8

12.3
5 L2
18 2 x M2.6
(L5) L1
2 x 4-40 UNC
28
DIN rail bracket mounting screw [For inch size thread]
(For DIN rail mounting) 34

1/4
[1(P), 5(EA), 3(EB) port]
M5 x 0.8 (External pilot)
[External pilot port]

∗: These figures show the “SS5Y5-50F2-05B-02”.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 123 135.5 148 173 185.5 210.5 223 235.5 260.5 273 298
L4 112.5 125 137.5 162.5 175 200 212.5 225 250 262.5 287.5
L5 17.5 15 12.5 16 13.5 17.5 15 12.5 16 13.5 17.5

253
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 50/Side Ported

Dimensions: SY7000 Series Metal Base D-sub Connector

U 02
C, N (D)
SS5Y7-50(R)F 12 - Stations D - KC, KN B
6.1

(Slide locking manual override)


50RF 12 - Stations UD
(81.2)

78.3
84
67.1

2B 2B
3

44.5
9.4
[Plug for external pilot]

32.4
4A 4A

2B

(For DIN rail


4A

10
10.8

mounting)
(Pitch)

14.3
46.6 P = 19
One-touch fitting
[4(A), 2(B) port] ∗ The above drawing shows when P,
Applicable tube O.D.: Ø 8, Ø 5/16" E port entry is D.
: Ø 10, Ø 3/8"
(Station 1) (Station n)
D side U side ∗: These figures show the “SS5Y7-50F2-05B-C10”.
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override

(Pitch) (Push-turn locking slotted type:


Applicable connector:D-sub
)
JIS-X-5101
MIL-C-24308
equivalent ( )
DIN rail holding screw Press, then rotate it.
52 P = 19 (Connector entry
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
16 24.1 (Light/surge voltage : Grey (For metal seal) upward direction)
DIN rail bracket mounting screw suppressor) 2(B) port side: Yellow
(8) M5 x 0.8 (External pilot)
(For DIN rail mounting)
PE: Pilot EXH port
(DIN rail)

B A B A B A B A B A
5.5

PE
14 A 14 A 14 A 14 A 14 A

5EA
116.7

23.8
28
102.1
35

133.2

92.1
84.6
24

1P
(59.9)

23.8
28.2
49.7

44.1

3EB
X
32.1

12 B 12 B 12 B 12 B 12 B
NC
NC

18.1
(5.4)

4 x Ø 4.5
(For mounting) 5 L2 20.9
(L5) L1 3/8 34.5
[1(P), 5(EA), 3(EB) port] 40.5
M5 x 0.8 (External pilot)
X: External pilot port
Port size 02 One-touch fitting (Replaceable) 2 x M2.6
2 x 4-40 UNC
[For N or T thread]

2B 2B
44.5

44.5
10.3
9.4
32.4

31.5

4A 4A

10.8 (Pitch)
(Pitch) 55.7 P = 19
46.6 P = 19 (11)
One-touch fitting
1/4 (22.9) [4(A), 2(B) port]
[4(A), 2(B) port] (For Ø 12) Applicable tube O.D.: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
: Ø 12

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 123 148 160.5 185.5 198 223 235.5 260.5 273 298 310.5
L4 112.5 137.5 150 175 187.5 212.5 225 250 262.5 287.5 300
L5 15.5 18.5 15.5 18.5 15 18 15 18 14.5 17.5 14.5
254
SY3000/5000/7000 Series
Plug-in Type 50/Side Ported

Dimensions: SY3000 Series Metal Base Flat Ribbon Cable

P U M5
SS5Y3-50(R) PG 21 - Stations D - KC
C, N
, KN
(D)
PH B 50PJG (20 pins) 50PH (10 pins)
Triangle mark
(Station 1)---(Station n) Triangle mark
For PC wiring
18

manual override)
(Slide locking
(81.4)

68.3
62.6
54.6

2B 2B

5EA

5EA
PCW type
PE

PE
7.1

32
22.6
4A 4A

1P

1P
X

X
3EB

3EB
(For DIN rail
mounting)
7.5
C2, C3: 5.4

11.8
C4, C6: 6.6 Applicable connector: Applicable connector:
20 pins MIL type with strain relief 10 pins MIL type with strain relief
C2, C3: 42.4 (Pitch) (Conforming to MIL-C-83503) (Conforming to MIL-C-83503)
C4, C6: 41.8 P = 10.5 One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 2
: Ø 3.2, Ø 1/8"
: Ø 4, Ø 5/32"
D side U side
L3 : Ø 6, Ø 1/4"
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override
Applicable connector:

DIN rail holding screw 45.1


(Pitch)
P = 10.5
(
Push-turn locking slotted type:
Press, then rotate it. ) 26 pins MIL type with strain relief
(Conforming to MIL-C-83503)
Light/surge 4(A) port side : Blue (For rubber seal)
(For DIN rail mounting) 14 24.1
4 x Ø 4.5 : Grey (For metal seal) M5 x 0.8 (External pilot) Triangle mark
voltage
(8) suppressor 2(B) port side : Yellow [Pilot EXH port]
(For mounting)

DIN rail

B A B A B A B A B A
(Connector entry
92.7

PE
5EA
89

14 A 14 A 14 A 14 A 14 A
16.8 17.2
15.9 16.2
79
5.5

upward direction)
64.4
35

56.9
21.8 16

1P
32.2

29.8
26.6

12 B 12 B 12 B 12 B 12 B
3EB

8.6 M5 x 0.8 (External pilot)


Replaceable:7.7)

4 L2 8
[External pilot port]
(L5) L1 14.5
1/8
(Fixed:4.1

22.1
DIN rail bracket mounting screw [1(P), 5(EA), 3(EB) port]
(For DIN rail mounting) 28

∗: These figures show the


Port size M5 One-touch fitting (Replaceable) “SS5Y3-50P2-05B-C6”.
∗: Only connectors are different for
50PG, 50PH and 50J.
L1 to L5 dimensions are the same
as 50P type.

2B 2B
50R PJ 12 - Stations UD
7.1

7.1
32

32
22.6

22.6

4A 4A

3
6.6 M5 x 0.8 (Pitch) [Plug for external pilot]
[4(A), 2(B) port] 48.4 P = 10.5 2B
(Pitch)
41.8 P = 10.5 One-touch fitting 4A

[4(A), 2(B) port]


Applicable tube O.D.: Ø 2
: Ø 3.2, Ø 1/8"
: Ø 4, Ø 5/32" ∗ The above drawing shows when P,
: Ø 6, Ø 1/4" E port entry is D.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17
255
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 50/Side Ported

Dimensions: SY3000 Series Metal Base Flat Ribbon Cable

P U
SS5Y3-50(R) PG 21 - Stations D -01(D)
PH B
(Station 1) ----- (Station n)
50R PJ 12 - Stations UD
18

manual override)
(Slide locking
(81.4)

68.3
62.6
[Plug for external pilot]
54.6

2B 2B 2B

7.1

32
22.6
4A 4A 4A

(For DIN rail


6.6

mounting)
(Pitch)

7.5
∗ The above drawing shows when P,

11.8
41.8 P = 12.5
E port entry is D.
1/8
[4(A), 2(B) port]

D side U side
L3
5.3 L4 Manual override Applicable connector:
(DIN rail mounting hole pitch: 12.5)
(Pitch) (
Push-turn locking slotted type:
Press, then rotate it. ) 26 pins MIL type with strain relief
(Conforming to MIL-C-83503)
DIN rail holding screw 45.1 P = 12.5 4(A) port side : Blue (For rubber seal)
: Grey (For metal seal) Triangle mark
(For DIN rail mounting) 14 24.1 Light/surge
2(B) port side : Yellow M5 x 0.8 (External pilot)
voltage
DIN rail bracket mounting screw (8) suppressor [Pilot EXH port]
(For DIN rail mounting)
DIN rail

B A B A B A B A B A
92.7
89

5EA

PE
14 A 14 A 14 A 14 A 14 A

16.8 17.2
15.9 16.2
79
5.5

64.4
35

56.9
21.8 16

1P
32.2

29.8
26.6

X
12 B 12 B 12 B 12 B 12 B

3EB
4 x Ø 4.5 4 L2 8 8.6
1/8
(For mounting)
(L5) L1 [1(P), 5(EA), 3(EB) port] 14.5
22.1 (Connector entry
upward direction)
28
50PJG (20 pins) 50PH (10 pins) M5 x 0.8 (External pilot)
Triangle mark [External pilot port]

For PC wiring Triangle mark

∗: These figures show the “SS5Y3-50P2-05B-01”.


∗: Only connectors are different for 50PG, 50PH and 50J.
L1 to L5 dimensions are the same as 50P type.
5EA

5EA
PCW type
PE

PE
1P

1P
X

X
3EB

3EB

Applicable connector: Applicable connector:


20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5
L4 100 112.5 125 137.5 150 162.5 175 187.5 200 212.5 225
L5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5

256
SY3000/5000/7000 Series
Plug-in Type 50/Side Ported

Dimensions: SY5000 Series Metal Base Flat Ribbon Cable

P U 01
SS5Y5-50(R) PG 21 - Stations D - KC
C, N
, KN
(D)
PH B 50PJG (20 pins) 50PH (10 pins)
(Station 1) ----------- (Station n)
18 Triangle mark
Triangle mark
For PC wiring

manual override)
(Slide locking
(87.4)

74.3
68.6
60.6

2B 2B

7.8

38

PCW type
PE

PE
27.3

5EA

5EA
4A 4A

1P

1P
10

(For DIN rail


mounting)
8.4

3EB

3EB
(Pitch)

X
14.3
45.8 P = 16
One-touch fitting
[4(A), 2(B) port] Applicable connector: Applicable connector:
Applicable tube O.D.: Ø 4, Ø 5/32" 20 pins MIL type with strain relief 10 pins MIL type with strain relief
: Ø 6, Ø 1/4"
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)
: Ø 8, Ø 5/16"
D side L3 U side
Applicable connector:
5.3 L4 26 pins MIL type with strain relief
Manual override
(DIN rail mounting hole pitch: 12.5) (Conforming to MIL-C-83503)
DIN rail holding screw
(For DIN rail mounting) 50
(Pitch)
P = 16
(
Push-turn locking slotted type:
Press, then rotate it. ) Triangle mark
4(A) port side : Blue (For rubber seal) M5 x 0.8 (External pilot)
Light/surge
16 24.1 : Grey (For metal seal)
DIN rail bracket mounting screw voltage [Pilot EXH port]
(8) suppressor 2(B) port side : Yellow
(For DIN rail mounting)

DIN rail

B A B A B A B A B A

PE
14 A 14 A 14 A 14 A 14 A
(Connector entry

5EA
106.2
5.5

23.2
116.6

96.2
35

20

upward direction)
81.6
74.1
20

1P
24.6
20
49.4

43.8

40.2

3EB
30.2

8
X
12 B 12 B 12 B 12 B 12 B

12.3
)

5 L2
Replaceable: 8.5

4 x Ø 4.5 18
(L5) L1
(For mounting) 28
Fixed: 4.9

34 M5 x 0.8 (External pilot)


∗: These figures show the “SS5Y5-50P2-05B-C8”. [External pilot port]
∗: Only connectors are different for 50PG, 50PH and 50J. 1/4
L1 to L5 dimensions are the same as 50P type. [1(P), 5(EA), 3(EB) port]
(

Port size 01 One-touch fitting (Replaceable)

50R PJ 12 - Stations UD

2B
2B 3
9.8

38
27.3
7.8

[Plug for external pilot]


38
27.3

4A
4A
2B

One-touch fitting 4A

8.4 (Pitch) [4(A), 2(B) port]


(Pitch)
51.6 P = 16 Applicable tube O.D.: Ø 4, Ø 5/32"
45.8 P = 16 : Ø 6, Ø 1/4"
1/8 : Ø 8, Ø 5/16" ∗ The above drawing shows when P,
[4(A), 2(B) port] E port entry is D.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5

257
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 50/Side Ported

Dimensions: SY5000 Series Metal Base Flat Ribbon Cable

P U
SS5Y5-50(R) PG 21 - Stations D -02(D)
PH B
50R PJ 12 - Stations UD
(Station 1) ------------- (Station n)
18

manual override)
3

(Slide locking
[Plug for external pilot]
(87.4)

74.3
2B

68.6
60.6

2B 2B
4A

9.8

38
27.3
4A 4A

10
∗ The above drawing shows when P,

(For DIN rail


1/4

mounting)
8.4 E port entry is D.
(Pitch)

14.3
[4(A), 2(B) port]
45.8 P = 17.5

D side U side
L3
5.3 L4 Manual override Applicable connector:
(DIN rail mounting hole pitch: 12.5) 26 pins MIL type with strain relief
DIN rail
holding screw
(Pitch)
P = 17.5
(
Push-turn locking slotted type:
Press, then rotate it. ) (Conforming to MIL-C-83503)
Triangle mark
50 4(A) port side : Blue (For rubber seal)
(For DIN Light/surge
16 24.1 : Grey (For metal seal) M5 x 0.8 (External pilot)
rail mounting) voltage suppressor 2(B) port side : Yellow
(8) [Pilot EXH port]

DIN rail

B A B A B A B A B A

PE
14 A 14 A 14 A 14 A 14 A
(Connector entry

5EA
106.2
5.5

23.2
116.6

96.2
35

20
upward direction)
81.6
74.1
20

1P
24.6
20
49.4

43.8

40.2

3EB
30.2

X
12 B 12 B 12 B 12 B 12 B 8

12.3
5 L2
18
(L5) 4 x Ø 4.5
L1 M5 x 0.8 (External pilot)
(For mounting) 28
DIN rail bracket mounting screw [External pilot port]
34
(For DIN rail mounting) 1/4
[1(P), 5(EA), 3(EB) port]
50PJG (20 pins) 50PH (10 pins)
Triangle mark
Triangle mark
For PC wiring
∗: These figures show the “SS5Y5-50P2-05B-02”.
∗: Only connectors are different for 50PG, 50PH and 50J.
L1 to L5 dimensions are the same as 50P type.
PCW type
PE

PE
5EA

5EA
1P

1P
3EB

3EB
X

Applicable connector: Applicable connector:


20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 123 135.5 148 173 185.5 210.5 223 235.5 260.5 273 298
L4 112.5 125 137.5 162.5 175 200 212.5 225 250 262.5 287.5
L5 17.5 15 12.5 16 13.5 17.5 15 12.5 16 13.5 17.5

258
SY3000/5000/7000 Series
Plug-in Type 50/Side Ported

Dimensions: SY7000 Series Metal Base Flat Ribbon Cable

P U 02
SS5Y7-50(R) PG 21 - Stations D - KC
C, N
, KN
(D)
PH B
50PJG (20 pins) 50PH (10 pins)
(Station 1) (Station n)
18 For PC wiring Triangle mark Triangle mark

manual override)
(Slide locking
(93.9)

78.3
84
67.1

2B 2B

PE

PE
PCW type
5EA

5EA
44.5
9.4
32.4
4A 4A

1P

1P
3EB

3EB
X

X
(For DIN rail
10.8

mounting)
10
(Pitch)

14.3
46.6 P = 19
One-touch fitting
[4(A), 2(B) port] Applicable connector: Applicable connector:
Applicable tube O.D.: Ø 8, Ø 5/16" 20 pins MIL type with strain relief 10 pins MIL type with strain relief
: Ø 10,Ø 3/8" (Conforming to MIL-C-83503) (Conforming to MIL-C-83503)
D side U side
L3
5.3 L4 Applicable connector:
(DIN rail mounting hole pitch: 12.5) Manual override 26 pins MIL type with strain relief
DIN rail (Conforming to MIL-C-83503)
holding screw 52
(Pitch)
P = 19
( Push-turn locking slotted type:
Press, then rotate it. ) Triangle mark
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
16 24.1 (Light/surge voltage : Grey (For metal seal) M5 x 0.8 (External pilot)
DIN rail bracket suppressor)
(8) 2(B) port side: Yellow PE: Pilot EXH port
mounting screw
(For DIN rail mounting)

(DIN rail) B A B A B A B A B A

PE
14 A 14 A 14 A 14 A 14 A

5EA
116.7
5.5

23.8
35

28
102.1
133.2

92.1
84.6
24

1P
23.8
59.9

28.2
49.7

44.1

8 (Connector
3EB
X
32.1

12 B 12 B 12 B 12 B 12 B entry upward
direction)
NC
NC

4 x Ø 4.5
18.1
(5.4)

(For mounting) 5 L2
20.9
(L5) L1
3/8 34.5
[1(P), 5(EA), 3(EB) port] 40.5
∗: These figures show the “SS5Y7-50P2-05B-C10”. M5 x 0.8 (External pilot)
X: External pilot port

Port size 02 One-touch fitting (Replaceable) 50RF12 - Stations UD

3
[Plug for external pilot]

2B 2B 2B
44.5

44.5
10.3
9.4
32.4

31.5

4A 4A 4A

55.7 (Pitch) P = 19
10.8 (Pitch) ∗ The above drawing shows when P,
46.6 P = 19 One-touch fitting E port entry is D.
(11)
[4(A), 2(B) port]
1/4 Applicable tube O.D.: Ø 6 ,Ø 1/4"
(22.9)
[4(A), 2(B) port] : Ø 8, Ø 5/16"
(For Ø 12) : Ø 10, Ø 3/8"
: Ø 12

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 123 148 160.5 185.5 198 223 235.5 260.5 273 298 310.5
L4 112.5 137.5 150 175 187.5 212.5 225 250 262.5 287.5 300
L5 15.5 18.5 15.5 18.5 15 18 15 18 14.5 17.5 14.5
259
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 51/Bottom Ported

Dimensions: SY3000 Series Metal Base D-sub Connector

M5, 01
SS5Y3-51F 12- Stations D- CKC, N, 
KN

(Pitch)
46.4 P = 10.5 One-touch fitting
23.6 [4(A), 2(B) port] Panel fitting dimensions
4 x M4 x 0.7, thread depth 4 Applicable tube O.D.: Ø 2

(For 9 stations or more)


: Ø 3.2, Ø 1/8"
16.8
(For mounting)

21.1
: Ø 4, Ø 5/32" 2 x Ø 4.5
: Ø 6, Ø 1/4" (For 9 stations or more)

4
29.8

3EB 2B 2B

56.4
40

17.8
1P

5EA 4A 4A (For 9 stations or more)


16.8

Cut dimensions for panel mounting 4 x Ø 4.5


1/8

52.4
C2, C3, C4 : 16
: 15

56.4
16
Refer to panel cut dimensions for details.
[1(P), 5(EA), 3(EB) port]
2 x M4 x 0.7 L3 4 x M4 x 0.7
(For 9 stations or more) L2 C6 4 x Ø 4.5 4 4
(Station 1) ---(Station n) L3
6.1
L2
manual override)
(Slide locking
(68.7)

68.3
62.6
54.6

32

Light/surge voltage suppressor


(4.1)

Manual override
2 x M2.6

(Pitch)
(
Push-turn locking slotted type:
Press, then rotate it. ) 2 x 4-40 UNC
[For N or T thread]
4(A) port side : Blue (For rubber seal)
D side 45.1 P = 10.5 U side : Grey (For metal seal)
14 24.1 2(B) port side : Yellow
(8)
4 x Ø 4.5
(For mounting)
16

B A B A B A B A B A
92.7
89

14 A 14 A 14 A 14 A 14 A
64.4
32.2

12 B 12 B 12 B 12 B 12 B
21.8

(Max. 3) L1
Port size M5 Port size 01 One-touch fitting (Replaceable)
32

32

) 32
C6: 12.8
N7: 16.6

(Pitch) (Pitch) (Pitch)


P = 10.5
21.1

46.4 P = 10.5 46.4 P = 12.5 46.4


20.1

20.1
(
29.8

29.8

29.8

3EB 2B 3EB 2B 3EB 2B


17

17

1P 1P 1P

5EA 4A 5EA 4A 5EA 4A


14

M5 x 0.8 1/8 One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: Ø 2
: Ø 3.2, Ø 1/8"
: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"

Port Sizes M5, C, N, KC, KN


n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 — — — — — — — 68.5 73.8 79 84.3

Port Size 01
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 — — — — — — — 77.8 84 90.3 96.5

260
SY3000/5000/7000 Series
Plug-in Type 51/Bottom Ported

Dimensions: SY5000 Series Metal Base D-sub Connector

01, 02
SS5Y5-51F 12- Stations D- CKC, N, 
KN

(Pitch)
50 P = 16
24 2 x M4 x 0.7 One-touch fitting
4 x M4 x 0.7, thread depth 5 (For 9 stations or more) [4(A), 2(B) port] Panel fitting dimensions
(For mounting)
Applicable tube O.D.: Ø 4, Ø 5/32"
40.2

3EB 2B 2B : Ø 6, Ø 1/4" 2 x Ø 4.5

25.2
: Ø 8, Ø 5/16"
20 20

(For 9 stations or more)

71.6

5
1P

4 x Ø 4.5
5EA 4A 4A

61.6
71.6
Cut dimensions for panel mounting

20
1/4
C4, C6 : 14.8
: 17.2
Refer to panel cut dimensions for details. 4 x M4 x 0.7
[1(P), 5(EA), 3(EB) port]
L3 4 x Ø 4.5
5 5
L2
C8

L3
6.1 (Station 1) ------ (Station n) L2
manual override)
(Slide locking
(74.7)

74.3
68.6
60.6

38

Light/surge voltage suppressor


(4.9)

Manual override
2 x M2.6
D side 50
(Pitch)
P = 16 U side (
Push-turn locking slotted type:
Press, then rotate it. ) 2 x 4-40 UNC
[For inch size thread]
4(A) port side : Blue (For rubber seal)
16 24.1 : Grey (For metal seal)
2(B) port side : Yellow
(8)
4 x Ø 4.5
(For mounting)
B A B A B A B A B A
106.2

14 A 14 A 14 A 14 A 14 A
116.6

81.6
30.2 20
49.4

12 B 12 B 12 B 12 B 12 B

(Max. 3) L1
∗: These figures show the “SS5Y5-
Port size 01 Port size 02 One-touch fitting (Replaceable)
51F2-05D-C8”.
(Pitch) (Pitch) (Pitch)
50 P = 16 50 P = 17.5 50 P = 16
9.7
40.2

40.2

40.2

3EB 2B 3EB 2B 3EB 2B

1P 1P 1P
17.5

14.5
14.8

5EA 4A 5EA 4A 5EA 4A

1/8 1/4 One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
38

38

38
(15.5)

Port Sizes 01, C, N, KC, KN


n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 — — — — — — — 93 101 109 117

Port Size 02
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 — — — — — — — 100.5 109.3 118 126.8

261
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 51/Bottom Ported

Dimensions: SY7000 Series Metal Base D-sub Connector

02
SS5Y7-51F 12 - Stations D- CKC, N, 
KN
(D)
Port size 02 One-touch fitting (Replaceable)
(Pitch) 3/8
(Max. 3) 52 P = 19 [1(P), 5(EA), 3(EB) port]

(For Ø 12)
M4 x 0.7 thread depth 5

(29.5)
(For 9 stations or more)
27
Fitting dimensions for
panel mounting
5

22 33.1 Refer to panel fitting


46.1

3EB 2B 2B
dimensions for details.

(17.6)
23 23
81.1

1P

5EA 4A 4A

One-touch fitting
[4(A), 2(B) port]
L3 Applicable tube O.D. C8 : Ø 8 One-touch fitting
C10: Ø 10
5 L2 [4(A), 2(B) port]
N9 : Ø 5/16"
L1 N11: Ø 3/8" Applicable tube O.D.: Ø 6, Ø 1/4"
1/4" : Ø 8, Ø 5/16"
4 x M4 x 0.7 thread depth 5 [4(A), 2(B) port] : Ø 10, Ø 3/8"
(For mounting) : Ø 12

32.8
22 33.1
3EB 2B 3EB 2B

6.1 (Station 1) (Station n)


1P
manual override)

1P
(Slide locking

22.6
(81.2)

5EA 4A 5EA 4A
78.3
84
67.1

44.5

(5.4)

D side U side
Manual override
(Light/surge voltage suppressor)
(
Push-turn locking slotted type:
Press, then rotate it. )
52
(Pitch)
P = 19 4(A) port side: Blue (For rubber seal)
: Grey (For metal seal)
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent
16 24.1
(8) 2(B) port side: Yellow

4 x Ø 4.5
B A B A B A B A B A

(For mounting) 14 A 14 A 14 A 14 A 14 A
116.7
133.2

92.1
84.6
32.1 24
59.9

(Connector entry upward direction)


12 B 12 B 12 B 12 B 12 B
NC
NC

2 x M2.6
2 x 4-40 UNC
[For N or T thread]

Panel fitting dimensions ∗: These figures show the “SS5Y7-51F2-05D-C10”.

4 x Ø 4.5 2 x Ø 4.5
(For 9 stations or more)
5

24 27.1
81.1
72.1

4 x M4 x 0.7
5 5 4 x Ø 4.5
L3
L2

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 — — — — — — — 107.5 117 126.5 136
262
SY3000/5000/7000 Series
Plug-in Type 51/Bottom Ported

Dimensions: SY3000 Series Metal Base Flat Ribbon Cable

P M5, 01
SS5Y3-51 PG 21 - Stations D- CKC, N,   Panel fitting dimensions

(For 9 stations
PH KN

17.8 or more)
2 x Ø 4.5

4
46.4 P = 10.5 (For 9 stations or more)
(Pitch) One-touch fitting 40
23.6
[4(A), 2(B) port] (For 9 stations or more)
4 x M4 x 0.7, thread depth 4
Applicable tube O.D.: Ø 2 4 x Ø 4.5

21.1
16.8

(For mounting) : Ø 3.2, Ø 1/8"

52.4
56.4
16
: Ø 4, Ø 5/32"
29.8

3EB 2B 2B : Ø 6, Ø 1/4" 4 x M4 x 0.7

56.4
1P 4 x Ø 4.5
4 4
5EA 4A 4A

L3
16.8

Cut dimensions for panel mounting


L2
C2, C3, C4 : 16
: 15
1/8 Refer to panel cut dimensions for details.
[1(P), 5(EA), 3(EB) port] L3
2 x M4 x 0.7
L2 51PJG (20 pins) 51PH (10 pins)
(For 9 stations or more)
C6

(Station 1)---(Station n) Triangle Triangle


For PC wiring mark mark
18.8
manual override)
(Slide locking
(81.4)

68.3
62.6
54.6

PCW type
32
(4.1)

Light/surge voltage suppressor


D side U side Manual override Applicable connector: Applicable connector:
20 pins MIL type with strain relief 10 pins MIL type with strain relief
45.1 P = 10.5 (
Push-turn locking slotted type:
Press, then rotate it. ) (Conforming to MIL-C-83503) (Conforming to MIL-C-83503)
(Pitch) 4(A) port side : Blue (For rubber seal)
14 24.1 : Grey (For metal seal)
2(B) port side : Yellow
(8) Applicable connector:
4 x Ø 4.5 26 pins MIL type with strain relief
(For mounting) (Conforming to MIL-C-83503)
64.4
16

B A B A B A B A B A
92.7
89

14 A 14 A 14 A 14 A 14 A
32.2

12 B 12 B 12 B 12 B 12 B

(Connector entry
upward direction)
21.8

(Max. 3) L1
∗: These figures show the “SS5Y3-
Port size M5 Port size 01 One-touch fitting (Replaceable) 51P2-05D-C6”.
(Pitch) (Pitch) (Pitch)
20.1

21.1

20.1

46.4 P = 10.5 46.4 P = 12.5 46.4 P = 10.5


29.8

29.8

29.8

3EB 2B 3EB 2B 3EB 2B


17

17

1P 1P 1P

5EA 4A 5EA 4A 5EA 4A


14

One-touch fitting
M5 x 0.8 1/8
[4(A), 2(B) port]
[4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: Ø 2
: Ø 3.2, Ø 1/8"
: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
32

32

32
16.6 )
(C6:N7: 12.8

Port Sizes M5, C, N, KC, KN


n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 — — — — — — — 68.5 73.8 79 84.3

Port Size 01
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 — — — — — — — 77.8 84 90.3 96.5

263
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 51/Bottom Ported

Dimensions: SY5000 Series Metal Base Flat Ribbon Cable

P 01, 02
SS5Y5-51 PG 21 - Stations D- CKC, N, 
KN

PH Panel fitting dimensions
50 P = 16
2 x Ø 4.5

25.2
(Pitch)
2 x M4 x 0.7 (For 9 stations or more)

5
24 (For 9 stations or more) One-touch fitting 4 x Ø 4.5
x M4 x 0.7, thread depth 5 [4(A), 2(B) port]

61.6
71.6
(For mounting) Applicable tube O.D.: Ø 4, Ø 5/32"

20
: Ø 6, Ø 1/4" 4 x M4 x 0.7
40.2

3EB 2B 2B
: Ø 8, Ø 5/16"
4 x Ø 4.5
20 20

71.6
1P 5 5
L3
5EA 4A 4A
L2
Cut dimensions for panel mounting
1/4
C4, C6 : 14.8
: 17.2

Refer to panel cut dimensions for details.


[1(P), 5(EA), 3(EB) port]
L3 51PJG (20 pins) 51PH (10 pins)
L2
C8

For PC wiring Triangle mark Triangle mark


(Station 1) ------ (Station n)
18.8
manual override)
(Slide locking
(87.4)

PCW type
74.3
68.6
60.6

38
(4.9)

Manual override Applicable connector: Applicable connector:


Light/surge voltage suppressor
20 pins MIL type with strain relief 10 pins MIL type with strain relief

(Pitch)
(
Push-turn locking slotted type:
Press, then rotate it. )
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)
4(A) port side : Blue (For rubber seal)
50 P = 16
: Grey (For metal seal)
16 24.1 2(B) port side : Yellow Triangle mark Applicable connector:
(8) 26 pins MIL type with strain relief
4 x Ø 4.5
(Conforming to MIL-C-83503)
(For mounting)
D side B A B A B A B A B A
U side
106.2

14 A 14 A 14 A 14 A 14 A
116.6

81.6
30.2 20
49.4

12 B 12 B 12 B 12 B 12 B
(Connector entry
upward direction)
(Max. 3) L1
Port size 01 Port size 02 One-touch fitting (Replaceable)
∗: These figures show the “SS5Y5-
(Pitch) (Pitch) (Pitch) 51P2-05D-C8”.
50 P = 16 50 P = 17.5 50 P = 16
9.7
40.2

40.2

40.2

3EB 2B 3EB 2B 3EB 2B

1P 1P 1P
17.5

14.5
14.8

5EA 4A 5EA 4A
5EA 4A

1/8 1/4 One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
38

38

38
(15.5)

Port Sizes 01, C, N, KC, KN


n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 — — — — — — — 93 101 109 117

Port Size 02
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 — — — — — — — 100.5 109.3 118 126.8
264
SY3000/5000/7000 Series
Plug-in Type 51/Bottom Ported

Dimensions: SY7000 Series Metal Base Flat Ribbon Cable

P 02
SS5Y7-51 PG 21 - Stations D- CKC, N, 
KN
(D)
PH

Panel fitting dimensions 50PJG (20 pins) 51PH (10 pins)


Triangle mark
4 x Ø 4.5 2 x Ø 4.5 Triangle mark
For PC wiring
(For 9 stations or more)
5

24 27.1

PCW type
81.1
72.1

4 x M4 x 0.7
5 5 4 x Ø 4.5
L3
L2
Applicable connector: Applicable connector:
20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)
4 x M4 x 0.7 thread depth 5
(For mounting) 3/8
(Pitch)
(Max. 3) 52 P = 19 [1(P), 5(EA), 3(EB) port]
Port size 02 One-touch fitting (Replaceable)
M4 x 0.7 thread depth 5
27 (For 9 stations or more)
Fitting dimensions for
panel mounting
5

Refer to panel fitting


22 33.1

dimensions for details.


46.1

3EB 2B 2B
23 23
81.1

1P

5EA 4A 4A

One-touch fitting One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port]
L3 Applicable tube O.D. C8 : Ø 8 Applicable tube O.D.: Ø 6, Ø 1/4"
C10: Ø 10
5 L2 N9 : Ø 5/16"
: Ø 8, Ø 5/16"
L1 : Ø 10, Ø 3/8"
N11: Ø 3/8" : Ø 12
1/4
[4(A), 2(B) port]
18.8 (Station 1) (Station n)

32.8
22 33.1

3EB 2B 3EB 2B
manual override)
(Slide locking
(93.9)

1P 1P
78.3
84
67.1

22.6
44.5

5EA 4A 5EA 4A
(5.4)

D side U side
Manual override ∗: These figures show the “SS5Y7-51P2-05D-C10”.
(Light/surge voltage suppressor)
(Pitch)
(
Push-turn locking slotted type:
Press, then rotate it. )
52 P = 19 4(A) port side: Blue (For rubber seal)
: Grey (For metal seal) Applicable connector:
16 24.1
2(B) port side: Yellow Triangle mark 26 pins MIL type with strain relief
(8)
(Conforming to MIL-C-83503)

4 x Ø 4.5
B A B A B A B A B A

(For mounting) 14 A 14 A 14 A 14 A 14 A
116.7
133.2

92.1
84.6
32.1 24
59.9

(Connector entry upward direction)


12 B 12 B 12 B 12 B 12 B
NC
NC

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 — — — — — — — 107.5 117 126.5 136

265
266
Plug-in Metal Base
D-sub Connector Flat Ribbon Cable
Type 52
Top Ported
SY3000/5000/7000 Series ®

RoHS
How to Order Manifolds

SS5Y 3 52 F 1 05 D
q w e r t y u i o
q Series w Type e Connector type
3 SY3000 52 Top ported F: D-sub connector P: Flat ribbon cable
5 SY5000 52R Top ported, External pilot (25 pins) (26 pins)
7 SY7000

r Connector entry direction


1: Upward 2: Lateral

PG: Flat ribbon cable PH: Flat ribbon cable


(20 pins) (10 pins)

t Wiring type
— All double wiring∗1
All single wiring∗2
S
y Valve stations
∗1 All double wiring: 2-position single, double, 3-position, and 4-position
valves can be used on all manifold stations. F: D-sub connector (25 pins) P: Flat ribbon cable (26 pins)
∗2 All single wiring: Available only for the manifold which has 2-position Symbol Stations Note Symbol Stations Note
single for all stations 02 2 stations 02 2 stations
Note that 2-position double, 3-, or 4-position valves cannot be used. All All

∗ If a mix of single and double wiring is required, it is supplied as a double double


special order. 12 12 stations wiring 12 12 stations wiring
02 2 stations All 02 2 stations All
How to Order Manifold Assembly

single single
12 12 stations wiring 12 12 stations wiring

Example (SS5Y3-52F2-) PG: Flat ribbon cable (20 pins) PH: Flat ribbon cable (10 pins)
2-position double (24 VDC) Symbol Stations Note Symbol Stations Note
2-position single (24 VDC)
SY3130-5U1-C6 (3 sets) SY3230-5U1-C6 (1 set) 02 2 stations All 02 2 stations All

3-position closed double double


centre (24 VDC) 09 9 stations wiring 04 4 stations wiring
SY3330-5U1-C6 (1 set) 02 2 stations 02 2 stations
All All

single single
12 12 stations wiring 08 8 stations wiring
∗ This also includes the number of the blanking plate assembly.

Us
ide u P, E port entry i Thread type
ions U U side∗1 — Rc
tat D side∗1
S D 00F G
Manifold base 3 B Both sides 00N NPT
2
(5 stations) 1 00T
ide
∗1 Plugs are mounted on the opposite NPTF
SS5Y3-52F2-05D Ds side of the selected ports.

SS5Y3-52F2-05D ········· 1 set (Type 52 5-station manifold base part no.)


∗SY3130-5U1-C6 ··········· 3 sets (2-position single part no.)
o Mounting
∗SY3230-5U1-C6 ··········· 1 set (2-position double part no.) — Direct mounting
∗SY3330-5U1-C6 ··········· 1 set (3-position closed centre part no.) D DIN rail mounting (With DIN rail)
The asterisk denotes the symbol for the assembly.
D0 DIN rail mounting (Without DIN rail)
Prefix it to the part numbers of the valve, etc. D3 For 3 stations Specify a length longer

than that of the standard


• For the valve arrangement, the valve closest to the D side is considered the 1st station. For 12 stations rail.
D12
• Under the manifold part number, state the valves to be mounted in order
starting with the 1st station as shown in the figure above. If the arrangement ∗ Refer to page 319 for the fixation of DIN rail
becomes too complicated, specify the details on a manifold specification sheet. mounting type manifold.

267
Plug-in Metal Base SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported

q Series u Coil type !1 A, B port size


3 SY3000 — Standard Thread piping
5 SY5000 With power saving circuit Symbol Port size Applicable series
T
7 SY7000 (Continuous duty type) M5 M5 x 0.8 SY3000
∗ Be sure to select the power saving circuit 01 1/8 SY5000
type if the valve is to be continuously
w Type of actuation energised for long periods of time.
02 1/4 SY7000

1 Single ∗ Be careful of the energising time when the One-touch fitting (Metric)
2-position power saving circuit is selected. Refer to page Symbol A, B port SY3000 SY5000 SY7000
2 Double
3 Closed centre 316 for details. C2 Ø2  — —
4 3-position Exhaust centre C3 Ø 3.2  — —
5 Pressure centre i Rated voltage C4
C6
Ø4
Ø6






A∗1 4-position N.C./N.C. 5 24 VDC
B∗1 dual N.O./N.O. C8 Ø8 —  
6 12 VDC

C∗1 3-port N.C./N.O. C10 Ø 10 — —
C12 Ø 12 — — 
∗1 Only the rubber seal type is available
for the 4-position dual 3-port valve. o Light/surge voltage suppressor One-touch fitting (Inch)
and common specification Symbol A, B port SY3000 SY5000 SY7000
e Seal type Symbol With light
Surge voltage Common
suppressor specification
N1
N3
Ø 1/8"
Ø 5/32"






0 Rubber seal
— — — N7 Ø 1/4"   
1 Metal seal
R — Non-polar N9 Ø 5/16" —  
U  N11 Ø 3/8" — — 
r Pilot type S —

Positive
Z  common

R
Internal pilot
External pilot NS — Negative !2 Thread type
NZ  common — Rc
∗ For the non-polar type, be careful of surge F G
t Back pressure check valve voltage intrusion. N NPT
(Built-in valve type) Refer to page 317 for details. T NPTF
∗ Only “Z” and “NZ” types are available with a ∗ Only — is available for M5.
— None
power saving circuit.
H Built-in
∗ Only the rubber seal type is available.
∗ The back pressure check valve is not
!0 Manual override !3 Type of mounting screw
available for the 3-position type or the —: D: — Round head combination screw
SY7000. Non-locking Push-turn B Hexagon socket head cap screw
push type locking K Round head combination screw (Drop prevention type)
slotted H Hexagon socket head cap screw (Drop prevention type)
y Pilot valve option type ∗ For “K” and “H,” the valve body cover has a
— Standard (0.7 MPa) drop prevention construction to stop the
B Quick response type (0.7 MPa) mounting screws from falling out when the
K∗1 High pressure type (1.0 MPa) valve is removed for maintenance, etc.
E: F: ∗ When ordering a valve individually, the
∗1 Only the metal seal type is available base gasket is not included.
for the high pressure type. Push-turn Slide locking
locking lever type Since the base gasket is attached to the
type manifold, please order the base gasket
separately if it is needed for maintenance.
Refer to page 290 for base gasket and
mounting screw part numbers.
∗ “B” and “H” cannot be selected for the
individual SUP/EXH spacer assembly or
∗ Refer to page 36 for the safety slide locking interface regulator.
manual override.

Protective class
class # (Mark: )
268
SY3000/5000/7000 Series
Plug-in Type 52/Top Ported

Dimensions: SY3000 Series Metal Base D-sub Connector, Flat Ribbon Cable

F U
P 1 Stations D
SS5Y3-52(R) PG 2- -(D)
PH B
F
52R PJ 12 - Stations UD
(Station 1)---(Station n)
6.1

3
[Plug for external pilot]

)
C6: 76.8
N7: 80.6
(68.7)
62.6
54.6

(
32
∗ The above drawing shows when P,
E port entry is D.

(For DIN rail


7.5

mounting)
11.8
D side U side
L3
5.3 L4 Manual override

DIN rail holding screw


(DIN rail mounting hole pitch: 12.5)
(Pitch)
(
Push-turn locking slotted type:
Press, then rotate it. ) Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent
45.1 P = 10.5 4(A) port side : Blue (For rubber seal)
(For DIN rail mounting)
: Grey (For metal seal)
14 24.1 68.3
Light/surge 2(B) port side : Yellow
DIN rail bracket (8) (Slide locking manual override)
voltage
mounting screw suppressor M5 x 0.8 (External pilot)
(For DIN rail mounting)
[Pilot EXH port]

DIN rail
5.5

B A B A B A B A B A
(Connector entry
upward direction)
92.7

4A 4A 4A 4A 4A

5EA
89

PE
16.8 17.2
15.9 16.2
79
64.4
56.9
21.8 16

1P
2 x M2.6
32.2

11
32.1
35

29.8

X
26.6

2B 2B 2B 2B 2B
3EB
2 x 4-40 UNC
[For inch size thread]
4 x Ø 4.5 8.6
8 One-touch fitting
(For mounting) 4 L2 14.5
[4(A), 2(B) port] M5 x 0.8 (External pilot)
(L5) L1 Applicable tube O.D.: Ø 2 22.1 [External pilot port]
: Ø 3.2, Ø 1/8" 28
M5 x 0.8 1/8
: Ø 4, Ø 5/32"
[4(A), 2(B) port] : Ø 6, Ø 1/4" [1(P), 5(EA), 3(EB) port]

52P (26 pins) 52PG (20 pins) 52PH (10 pins)


For PC wiring
Triangle mark Triangle mark Triangle mark
14 (9.9) 14 (9.9) 14 (9.9)

B A B A B A
4A 4A 4A
5EA

5EA

5EA
PE

PE

PE
PCW type
1P

1P

1P
X

2B 2B 2B
3EB

3EB

3EB

Applicable connector: Applicable connector: Applicable connector:


26 pins MIL type with strain relief 20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17

269
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 52/Top Ported

Dimensions: SY5000 Series Metal Base D-sub Connector, Flat Ribbon Cable

F U
P 1 Stations D
SS5Y5-52(R) PG 2- -(D) F
52R PJ 12 - Stations UD
PH B
(Station 1)----------- (Station n)
6.1

3
[Plug for external pilot]

(86.7)
(74.7)
72.3

(For DIN rail


60.6

mounting)
14.3
38
∗ The above drawing shows when P,
E port entry is D.

10 Manual override

D side U side
(
Push-turn locking slotted type:
Press, then rotate it. )
L3 4(A) port side : Blue (For rubber seal)
DIN rail 5.3 L4 : Grey (For metal seal)
2(B) port side : Yellow
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent
holding screw (DIN rail mounting hole pitch: 12.5)
(For DIN rail (Pitch) 74.3
mounting) 50 P = 16 Light/surge (Slide locking manual override)
16 24.1 voltage 68.6
DIN rail bracket suppressor M5 x 0.8 (External pilot)
mounting screw (8) [Pilot EXH port]
01 : 16.2
C : 14.5

(For DIN
rail mounting)

DIN rail B A B A B A B A B A (Connector entry


4A 4A 4A 4A 4A

PE
5EA
upward direction)
106.2
5.5

23.2
116.6

96.2

20
35

81.6
74.1
20

1P
24.6
20
49.4

43.8
40.2

40.2

2 x M2.6

3EB
30.2

X
2B 2B 2B 2B 2B
2 x 4-40 UNC
[For inch size thread]

1/8 12.3
4 x Ø 4.5 One-touch fitting 18 M5 x 0.8 (External pilot)
[4(A), 2(B) port]
(For mounting) [4(A), 2(B) port] [External pilot port]
5 L2 28
Applicable tube O.D.: Ø 4, Ø 5/32" 1/4
(L5) L1 : Ø 6, Ø 1/4" 34
[1(P), 5(EA), 3(EB) port]
: Ø 8, Ø 5/16"

∗: These figures show the “SS5Y5-52F2-05B”.

52PH (10 pins) 52PG (20 pins) 52P (26 pins)


For PC wiring
16 (9.9) Triangle mark 16 (9.9) 16 (9.9) Triangle mark
Triangle mark

B A B A B A
4A 4A
PE

PE

4A
PE
5EA

5EA

5EA
PCW type
1P

1P

1P
3EB

3EB

3EB
X

2B 2B 2B

Applicable connector: Applicable connector: Applicable connector:


10 pins MIL type with strain relief 20 pins MIL type with strain relief 26 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5

270
SY3000/5000/7000 Series
Plug-in Type 52/Top Ported

Dimensions: SY7000 Series Metal Base D-sub Connector, Flat Ribbon Cable

F U
P 1 Stations D
SS5Y7-52(R) PG 2- -(D)
PH B
52PH (10 pins) 52P (26 pins)
Triangle mark 16 (9.9) Triangle mark 16 (9.9)
F
52R PJ 12 - Stations U
D

B A B A

PE

PE
4A 4A

5EA

5EA
3
[Plug for external pilot]

1P

1P
3EB

3EB
X

X
2B 2B

Applicable connector: Applicable connector:


∗ The above drawing shows when P, 10 pins MIL type with strain relief 26 pins MIL type with strain relief
E port entry is D. (Conforming to MIL-C-83503) (Conforming to MIL-C-83503)

52PG (20 pins)


∗:These figures show the “SS5Y7-52F2-05B”.
For PC wiring Triangle mark 16 (9.9)
(Station 1) (Station n)

6.1
B A
(A, B port: Ø 12)

PE
4A

PCW type
5EA
(110.3)
(98.4)

1P
(81.2)
87

67.1

44.5

3EB
X
2B
(For DIN rail

Applicable connector:
mounting)
10

20 pins MIL type with strain relief


14.3

(Conforming to MIL-C-83503)
D side U side
L3
DIN rail 5.3 L4
holding screw (DIN rail mounting hole pitch: 12.5)
Manual override Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent
(For DIN
rail mounting) 52
P = 19
(Pitch)
(Push-turn locking slotted type:
Press, then rotate it. ) 84
16 24.1 4(A) port side: Blue (For rubber seal) (Slide locking manual override)
(Light/surge voltage
suppressor) : Grey (For metal seal) M5 x 0.8 (External pilot) 78.3
DIN rail bracket
(8) 2(B) port side: Yellow
mounting screw PE: Pilot EXH port
(For DIN
rail mounting)
(DIN rail) B A B A B A B A B A
5.5

PE

4A 4A 4A 4A 4A
5EA
116.7

23.8
28
35

102.1
133.2

92.1
84.6
24

1P
23.8
59.9

28.2
49.7
45.6

44.1
22.6

3EB

8
X
32.1

2B 2B 2B 2B 2B
NC
NC

4 x Ø 4.5 1/4 3/8 18.1


(For mounting) [1 (A), 2 (B) port] [1 (P), 5 (EA), 3 (EB) port] 20.9
One-touch fitting 2 x M2.6
5 L2 34.5
[4(A), 2(B) port] 2 x 4-40 UNC
(L5) L1 Applicable tube O.D.: Ø 6, Ø 1/4" 40.5
[For N or T thread]
(Connector entry upward direction) : Ø 8, Ø 5/16" M5 x 0.8 (External pilot)
: Ø 10, Ø 3/8" X: External pilot port
: Ø 12

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 123 148 160.5 185.5 198 223 235.5 260.5 273 298 310.5
L4 112.5 137.5 150 175 187.5 212.5 225 250 262.5 287.5 300
L5 15.5 18.5 15.5 18.5 15 18 15 18 14.5 17.5 14.5
271
Plug-in Metal Base SY3000/5000/7000 Series

Electrical Wiring Specifications Connector Cable


D-sub connector GVVZS3000-21A- [IP40]
D-sub connector/cable
If alignment is not specified, the internal wiring is double
wiring (connected to SOL. a and SOL. b) regardless of Cable
1 Assembly part no. Note
14 number of stations, valve and option types. length (L)
2
15 3 1m GVVZS3000-21A-160 60°angled
16 4
17 3m GVVZS3000-21A-260 60°angled
5
18 6 5m GVVZS3000-21A-360 60°angled
19 7
20 8m GVVZS3000-21A-460 60°angled
8
21 9 3m GVVZS3000-21A-2 Standard
Connector terminal no.
22 10 5m GVVZS3000-21A-3 Standard
23 11
24 8m GVVZS3000-21A-4 Standard
12
25 13
Shielded cable
Cable
Assembly part no. Note
Lead wire no. Polarity length (L)
SOL. a Terminal Lead wire Dot 1m GVVZS3000-21A-1S Shieled
1 (−) (+) no. colour marking
Station 1 SOL. b 3m GVVZS3000-21A-2S Shieled
14 (−) (+)
SOL. a 1 Black None 5m GVVZS3000-21A-3S Shieled
2 (−) (+)
Station 2 SOL. b 15 8m GVVZS3000-21A-4S Shieled
(−) (+) 2 Brown None
SOL. a 20 m GVVZS3000-21A-5S Made to order
3 (−) (+) 3 Red None
Station 3 SOL. b 16 (−) (+) 4 Orange None
SOL. a 4 (−) (+)
Station 4 5 Yellow None
SOL. b 17 (−) (+)
SOL. a 5 (−) (+)
6 Pink None 60° angled Standard
Station 5 SOL. b 18 7 Blue None
(−) (+) 14 - - - - - -25
SOL. a (−) (+) 8 Purple White
6

20
L

Station 6 SOL. b 19 9 Grey Black


(−) (+)
SOL. a 10 White Black 1- - - - - - - -13
7 (−) (+)
Station 7 SOL. b

53.5
(−) (+) 11 White Red

2- M2.6
20
SOL. a
8 (−) (+) 12 Yellow Red
Station 8 SOL. b
21 (−) (+) 13 Orange Red
SOL. a
9 (−) (+) 14 Yellow Black
Station 9 SOL. b 22 (−) (+) 25 L
SOL. a 15 Pink Black
10 (−) (+) 41 41
Station 10 SOL. b 23 16 Yellow White
(−) (+)
15.2

SOL. a 17 White None


11 (−) (+)
Station 11 SOL. b 24 18 Grey None
(−) (+)
SOL. a 19 Orange Black 53
12 (−) (+)
Station 12 SOL. b 25 (−) (+) 20 Red White
Electrical characteristics
21 Brown White
COM. Item Property
13 (+) (−) 22 Pink Red
Conductor resistance 액/km, 20 °C Max. 57
Positive Negative 23 Grey Red
common common
Voltage limit V, 5 minute, AC 1500
24 Black White
Insulation resistance M액/km, 20 °C 20
∗ When using a valve with no polarity, either positive 25 White None
common or negative common can be used.

Standard
D-Sub connector cable assembly (option)
015
AXT100-DS25- 030 (According to MIL-C24308)
050

∗ Please contact SMC for details.

272
SY3000/5000/7000 Series

Electrical Wiring Specifications Cable Assembly


10 1
Flat ribbon cable connector AXT100-FC 20 -2
26 3
26 25
24 23
6 Terminal no. 28AWG
Red
22 21
20 19

17.2 (10 pins)


30 (20 pins)
37.5 (26 pins)

1
18 17
16 15
14 13
12 11 Connector terminal no.
10 9

26

25
8 7
Triangle mark indicator position (15.6)
6 5
4 3 L
2 1
Flat ribbon cable connector assembly
Cable Assembly part no.
P: Flat ribbon cable (26 pins) length (L) 26 pins 20 pins 10 pins
<All single wiring> <All double wiring> 1.5 m AXT100-FC26-1 AXT100-FC20-1 AXT100-FC10-1
Terminal no. Terminal no. Polarity 3m AXT100-FC26-2 AXT100-FC20-2 AXT100-FC10-2
SOL.a 1 SOL.a (–) (+) 5m AXT100-FC26-3 AXT100-FC20-3 AXT100-FC10-3
Station 1 1
Station 2
SOL.a 2 Station 1 SOL.b 2 (–) (+) ∗ When using a standard commercial connector, use a 26-pin, 20-pin, or
SOL.a 3 SOL.a 3 (–) (+)
Station 3 10-pin type connector conforming to MIL-C-83503 with strain relief.
Station 4
SOL.a 4 Station 2 SOL.b 4 (–) (+) ∗ Cannot be used for movable wiring
Station 5 SOL.a 5 SOL.a 5 (–) (+) ∗ Lengths other than the above are also available. Please contact SMC
Station 6
SOL.a 6 Station 3 SOL.b 6 (–) (+) for details.
Station 7 SOL.a 7 SOL.a 7 (–) (+)
Station 8 SOL.a 8 Station 4 SOL.b 8 (–) (+) Connector Manufacturer’s Example
Station 9 SOL.a 9 SOL.a 9 (–) (+)
Station 10 SOL.a 10 Station 5 SOL.b 10 (–) (+) • HIROSE ELECTRIC CO., LTD. • Japan Aviation Electronics Industry, Limited
Station 11 SOL.a 11 SOL.a 11 (–) (+) • 3M Japan Limited • J.S.T. Mfg. Co., Ltd.
Station 12 SOL.a 12 Station 6 SOL.b 12 (–) (+) • Fujitsu Limited • Oki Electric Cable Co., Ltd.
13 SOL.a 13 (–) (+)
Station 7 SOL.b 14
14 (–) (+)
15 SOL.a 15 (–) (+) PH: Flat ribbon cable (10 pins)
Station 8 SOL.b 16
16 (–) (+) <All single wiring> <All double wiring>
17 SOL.a 17 (–) (+)
Station 9 SOL.b 18 Terminal no. Terminal no. Polarity
18 (–) (+) SOL.a SOL.a
19 SOL.a 19 (–) (+) Station 1 1 1 (–) (+)
Station 10 SOL.a Station 1 SOL.b
SOL.b 20 (–) (+) Station 2 2 2 (–) (+)
20 SOL.a SOL.a
SOL.a 21 (–) (+) Station 3 3 3 (–) (+)
21 SOL.a Station 2 SOL.b
Station 11 SOL.b 22 Station 4 4 4 (–) (+)
22 (–) (+) SOL.a SOL.a
23 SOL.a 23 (–) (+) Station 5 5 5 (–) (+)
Station 12 SOL.a Station 3 SOL.b
24 SOL.b 24 (–) (+) Station 6 6 6 (–) (+)
Station 7 SOL.a SOL.a 7 (–) (+)
COM. COM. 7
25 25 (+) (–) SOL.a Station 4 SOL.b
COM. 26 COM. Station 8 8 8 (–) (+)
26 (+) (–) COM. COM.
9 9 (+) (–)
Positive Negative COM. 10 COM.
10 (+) (–)
common common
Positive Negative
common common
PG: Flat ribbon cable (20 pins)
<All single wiring> <All double wiring>
Terminal no. Terminal no. Polarity
SOL.a SOL.a (–) (+)
Station 1 1 1
SOL.a Station 1 SOL.b
Station 2 2 2 (–) (+)
SOL.a SOL.a 3 (–) (+)
Station 3 3
SOL.a Station 2 SOL.b
Station 4 4 4 (–) (+)
Station 5 SOL.a SOL.a 5 (–) (+)
5
SOL.a Station 3 SOL.b
Station 6 6 6 (–) (+)
Station 7 SOL.a SOL.a 7 (–) (+)
7
SOL.a Station 4 SOL.b
Station 8 8 8 (–) (+)
Station 9 SOL.a SOL.a 9 (–) (+)
9
SOL.a Station 5 SOL.b 10
Station 10 10 (–) (+)
Station 11 SOL.a SOL.a 11 (–) (+)
11
SOL.a Station 6 SOL.b 12
Station 12 12 (–) (+)
SOL.a 13 (–) (+)
13
Station 7 SOL.b 14
14 (–) (+)
SOL.a 15 (–) (+)
15
Station 8 SOL.b 16
16 (–) (+)
SOL.a 17 (–) (+)
17
Station 9 SOL.b 18
18 (–) (+)
COM. 19 COM.
19 (+) (–)
COM. 20 COM.
20 (+) (–)
Positive Negative
common common

∗ When using a valve with no polarity, either positive common or negative


common can be used.

273
274
Type 50
Side Ported Plug-in Metal Base EX510
Type 51
Bottom Ported
SY3000/5000/7000 Series ®

How to Order Manifolds

SS5Y 3 50 S5 05 D C6
q w e r t y u i o
q Series w Type t Valve stations
3 SY3000 50 Side ported Symbol Stations Note Symbol Stations Note
5 SY5000 51 Bottom ported 02 2 stations 02 2 stations
All double All single


7 SY7000 50R Side ported, External pilot
wiring wiring
∗ External pilot is not available 08 8 stations 12 12 stations
e SI unit output polarity for the bottom-ported type. ∗ This also includes the number of the blanking plate assembly.

N
Positive common
Negative common y P, E port entry
U U side∗1 ∗1 Plugs are mounted on the opposite
side of the selected ports.
r Wiring type D
B
D side∗1∗2
Both sides
∗2 Only D side is available for the type
— All double wiring∗1 51 bottom-ported type.
S All single wiring∗2 u A, B port size
∗1 All double wiring: 2-position single, double, 3-position, and 4-position Thread piping
valves can be used on all manifold stations.
∗2 All single wiring: Available only for the manifold which has 2-position
Symbol A, B port SY3000 SY5000 SY7000
single for all stations M5 M5 x 0.8  — —
Note that 2-position double, 3-, or 4-position valves cannot be used. 01 1/8   —
∗ If a mix of single and double wiring is required, it is supplied as a 02 1/4 —  
special order. One-touch fitting (Metric)
Symbol A, B port SY3000 SY5000 SY7000
C2 Ø2  — —
C3 Ø 3.2  — —
How to Order Manifold Assembly  
Fixed

C4 Ø4 —
C6 Ø6   —
Example (SS5Y3-50S5-) C8 Ø8 —  
2-position single (24 VDC) 2-position double (24 VDC) 
C10 Ø 10 — —
SY3100-5U1 (3 sets) SY3200-5U1 (1 set)
3-position closed KC2 Ø2  — — Type 50 Type 51
centre (24 VDC) KC3 Ø 3.2  — — (Side ported) (Bottom ported)
SY3300-5U1 (1 set)
KC4  
Replaceable

Ø4 —
KC6 Ø6   
KC8 Ø8 —  
KC10 Ø 10 — — 
KC12 Ø 12 — — 
ide M∗1 Mixed sizes   
Us
P, E port size (Thread piping) 1/8 1/4 3/8
s
n
tio
ta
S

One-touch fitting (Inch)


3
Manifold base 2 Symbol A, B port SY3000 SY5000 SY7000
1
(5 stations) e
Ds
id N1 Ø 1/8"  — —
SS5Y3-50S5-05D-C6
N3 Ø 5/32"   —
Fixed

SS5Y3-50S5-05D-C6 ··· 1 set (Type 50 5-station manifold base part no.)


N7 Ø 1/4"   —
∗SY3100-5U1 ················· 3 sets (2-position single part no.)
∗SY3200-5U1 ················· 1 set (2-position double part no.) N9 Ø 5/16" —  
∗SY3300-5U1 ················· 1 set (3-position closed centre part no.) N11 Ø 3/8" — — 
The asterisk denotes the symbol for the assembly. KN1 Ø 1/8"  — — Type 50 Type 51
Prefix it to the part numbers of the valve, etc. (Side ported) (Bottom ported)
KN3  
Replaceable

Ø 5/32" —
• For the valve arrangement, the valve closest to the D side is considered the 1st station.   
KN7 Ø 1/4"
• Under the manifold part number, state the valves to be mounted in order
starting with the 1st station as shown in the figure above. If the arrangement KN9 Ø 5/16" —  
becomes too complicated, specify the details on a manifold specification sheet. KN11 Ø 3/8" — — 
∗ When mixing top-ported configurations, select from those listed on page 285. In such M∗1 Mixed sizes   
cases, use caution as there is also output on the A and B ports on the base side.
P, E port size (Thread piping) 1/8 1/4 3/8
Specify on the manifold specification sheet if plugs are required for the A and B ports
on the base side. ∗1 When ports are of mixed sizes, indicate the piping specifications on the manifold specification sheet.
275
Plug-in Metal Base SY3000/5000/7000 Series

i Thread type o Mounting


— Rc — Direct mounting
F G DIN rail mounting
D (With DIN rail)
N NPT
T NPTF DIN rail mounting For details on the EX510 Gateway Type
D0 (Without DIN rail) Serial Transmission System, refer to the
D3 For 3 stations Specify a length longer Web Catalogue and the Operation Manual.
Please download the Operation Manual via


than that of the standard
D12 For 12 stations rail. the SMC website, https://www.smc.eu
∗ Only direct mounting is available for the type
51 bottom-ported type.
∗ Refer to page 319 for the fixation of DIN rail
mounting type manifold.

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 0 0 5 1
!0 Manual override
q w e r t y u i o !0 !1 —: D:
Non-locking Push-turn
Base mounted push type locking
slotted
q Series y Pilot valve option type
3 SY3000 — Standard (0.7 MPa)
5 SY5000 B Quick response type (0.7 MPa)
7 SY7000 K∗1 High pressure type (1.0 MPa)
E: F:
∗1 Only the metal seal type is available for the
Push-turn Slide locking
w Type of actuation high pressure type.
locking lever type
1
2-position
Single u Coil type type
2 Double
— Standard
3 Closed centre
T With power saving circuit (Continuous duty type)
4 3-position Exhaust centre
5 Pressure centre ∗ Be sure to select the power saving circuit
type if the valve is to be continuously ∗ Refer to page 36 for the safety slide locking
A∗1 N.C./N.C. energised for long periods of time.
4-position manual override.
B∗1 dual 3-port
N.O./N.O. ∗ Be careful of the energising time when the
C∗1 N.C./N.O. power saving circuit is selected. Refer to page
∗1 Only the rubber seal type is available for the
316 for details. !1 Type of mounting screw
i Rated voltage —
4-position dual 3-port valve. Round head combination screw
B Hexagon socket head cap screw
5 24 VDC
e Seal type K
H
Round head combination screw (Drop prevention type)
Hexagon socket head cap screw (Drop prevention type)
0 Rubber seal o Light/surge voltage suppressor ∗ For “K” and “H,” the valve body cover has a
1 Metal seal and common specification drop prevention construction to stop the
Surge voltage Common mounting screws from falling out when the
r Pilot type
Symbol With light valve is removed for maintenance, etc.
suppressor specification
∗ When ordering a valve individually, the
— Internal pilot R —
base gasket is not included.
Non-polar
R External pilot U  Since the base gasket is attached to the
S — manifold, please order the base gasket
 Positive common separately if it is needed for maintenance.
Z 
t Back pressure check valve NS — Refer to page 290 for base gasket and
(Built-in valve type) Negative common mounting screw part numbers.
NZ  ∗ “B” and “H” cannot be selected for the
— None
∗ For the non-polar type, be careful of surge individual SUP/EXH spacer assembly,
H Built-in voltage intrusion. Refer to page 317 for details. interface regulator, or double check spacer
∗ Only the rubber seal type is available. ∗ Only “Z” and “NZ” types are available with a assembly with residual pressure release valve.
∗ The back pressure check valve is not available power saving circuit. Select “R,” “U,” “S,” or “Z”
for the 3-position type or the SY7000. for the valve when the SI unit output polarity is
— (positive common). Select “R,” “U,” “NS,” or
“NZ” for the valve when the SI unit output Protective class
polarity is N (negative common). class # (Mark: )
276
SY3000/5000/7000 Series
Plug-in Type 50/Side Ported

Dimensions: SY3000 Series Metal Base EX510

U M5
SS5Y3-50(R)S5- Stations D - KC
C, N (D)
, KN B

(Station 1) ---(Station n)

50RS5- Stations UD

manual override)
(Slide locking
68.3
65.6

62.6
2B 2B
3

7.1

32
22.6
4A 4A [Plug for external pilot]
2B

4A

(For DIN rail


mounting)
C2, C3: 5.4 One-touch fitting

7.5
11.8
C4, C6: 6.6 [4(A), 2(B) port]
Applicable tube O.D.: Ø 2
C2, C3: 42.4 (Pitch) : Ø 3.2, Ø 1/8" ∗ The above drawing shows when P,
C4, C6: 41.8 P = 10.5 : Ø 4, Ø 5/32" E port entry is D.
: Ø 6, Ø 1/4"

D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override
(Pitch)
DIN rail holding screw
45.1 P = 10.5 (
Push-turn locking slotted type:
Press, then rotate it. ) M5 x 0.8 (External pilot)
18.5 19.6 Light/surge 4(A) port side : Blue (For rubber seal)
(For DIN rail mounting) [Pilot EXH port]
voltage : Grey (For metal seal)
DIN rail bracket mounting screw suppressor 2(B) port side : Yellow
(For DIN rail mounting)
DIN rail

B A B A B A B A B A
92.7

5EA
14 A 14 A 14 A 14 A 14 A
89

PE
16.8 17.2
15.9 16.2
79
5.5

64.4
35

56.9
21.8 16

1P
29.8

X
26.6

12 B 12 B 12 B 12 B 12 B

3EB

4 x Ø 4.5 SI unit 8 8.6


Replaceable: 7.7 )

(For mounting) 14.5


4 L2
(L5) L1 22.1
4.1

28 M5 x 0.8 (External pilot)


( Fixed:

[External pilot port]


∗: These figures show the “SS5Y3-50S5-05B-C6”. 1/8
[1(P), 5(EA), 3(EB) port]

Port size M5 One-touch fitting (Replaceable)

2B 2B
7.1
7.1

32

32
22.6

22.6

4A 4A

One-touch fitting
M5 x 0.8 [4(A), 2(B) port]
[4(A), 2(B) port] Applicable tube O.D.: Ø 2
6.6 (Pitch)
(Pitch) : Ø 3.2, Ø 1/8"
41.8 P = 10.5 : Ø 4, Ø 5/32"
48.4 P = 10.5
: Ø 6, Ø 1/4"

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17

277
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 50/Side Ported

Dimensions: SY3000 Series Metal Base EX510

U
SS5Y3-50(R)S5- Stations D -01(D)
B

(Station 1)------ (Station n)


50RS5- Stations UD

manual override)
(Slide locking
68.3
3
65.6

62.6
2B 2B [Plug for external pilot]

7.1
2B

32
22.6
4A 4A
4A

(For DIN rail


6.6

mounting)
(Pitch) 1/8

7.5
P = 12.5

11.8
41.8 [4(A), 2(B) port]
∗ The above drawing shows when P,
E port entry is D.

D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override
M5 x 0.8 (External pilot)

DIN rail holding screw 45.1


(Pitch)
P = 12.5 (Push-turn locking slotted type:
Press, then rotate it. ) [Pilot EXH port]

18.5 19.6 4(A) port side : Blue (For rubber seal)


(For DIN rail mounting) Light/surge voltage : Grey (For metal seal)
suppressor 2(B) port side : Yellow
DIN rail bracket mounting screw
(For DIN rail mounting)

DIN rail
B A B A B A B A B A
92.7

5EA
14 A 14 A 14 A 14 A 14 A
89

PE
16.8 17.2
15.9 16.2
79
5.5

64.4
35

56.9
21.8 16

1P
29.8

X
26.6

12 B 12 B 12 B 12 B 12 B
3EB

4 x Ø 4.5 SI unit 8 8.6


(For mounting) 4 L2 14.5
(L5) L1 22.1 M5 x 0.8 (External pilot)
28 [External pilot port]
1/8
[1(P), 5(EA), 3(EB) port]

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5
L4 100 112.5 125 137.5 150 162.5 175 187.5 200 212.5 225
L5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5

278
SY3000/5000/7000 Series
Plug-in Type 50/Side Ported

Dimensions: SY5000 Series Metal Base EX510

U 01
SS5Y5-50(R)S5- Stations D - KC
C, N (D)
, KN B
(Station 1)----------- (Station n)
50RS5- Stations UD

manual override)
(Slide locking
3

74.3
71.6

[Plug for external pilot]

68.6
2B 2B 2B

7.8

38
27.3
4A 4A 4A

(For DIN rail


8.4

10

mounting)
(Pitch) One-touch fitting
∗ The above drawing shows when P,

14.3
45.8 P = 16 [4(A), 2(B) port] E port entry is D.
Applicable tube O.D.: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"

D side U side
L3
DIN rail 5.3 L4 M5 x 0.8 (External pilot)
Manual override
holding screw (DIN rail mounting hole pitch: 12.5) [Pilot EXH port]
(For DIN
rail mounting) 50
(Pitch)
P = 16
( Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
DIN rail bracket 20.5 19.6 Light/surge voltage : Grey (For metal seal)
mounting screw suppressor 2(B) port side : Yellow
(For DIN
rail mounting)
DIN rail
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A

PE
5EA
106.2
5.5

116.6

23.2
35

96.2

20
81.6
74.1
20

1P
24.6
20
43.8

40.2

3EB
30.2

X
12 B 12 B 12 B 12 B 12 B

4 x Ø 4.5
)Replaceable: 8.5

SI unit 12.3
(For mounting)
5 L2 18 M5 x 0.8 (External pilot)
Fixed: 4.9

(L5) L1 28 [External pilot port]


34
1/4
[1(P), 5(EA), 3(EB) port]
∗: These figures show the “SS5Y5-50S5-05B-C8”.
(

Port size 01 One-touch fitting (Replaceable)

2B 2B
7.8

9.8
38

38
27.3

27.3

4A 4A

One-touch fitting
8.4 1/8 [4(A), 2(B) port]
(Pitch) Applicable tube O.D.: Ø 4, Ø 5/32"
[4(A), 2(B) port]
45.8 P = 16
(Pitch) : Ø 6, Ø 1/4"
51.6 P = 16 : Ø 8, Ø 5/16"

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5

279
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 50/Side Ported

Dimensions: SY5000 Series Metal Base EX510

U
SS5Y5-50(R)S5- Stations D -02(D)
B

(Station 1) ------------- (Station n) 50RS5- Stations UD

manual override)
(Slide locking
3
[Plug for external pilot]

74.3
71.6

68.6
2B 2B 2B

9.8

38
27.3
4A 4A 4A

(For DIN rail


∗ The above drawing shows when P,

10
8.4

mounting)
(Pitch) 1/4

14.3
45.8 P = 17.5 [4(A), 2(B) port] E port entry is D.

D side U side
L3
M5 x 0.8 (External pilot)
5.3 L4
Manual override [Pilot EXH port]
(DIN rail mounting hole pitch: 12.5)
DIN rail holding screw
(For DIN rail mounting)
50
(Pitch)
P = 17.5
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
20.5 19.6 Light/surge voltage : Grey (For metal seal)
DIN rail bracket mounting screw suppressor
(For DIN rail mounting) 2(B) port side : Yellow

DIN rail

B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A

PE
5EA
106.2
5.5

23.2
116.6
35

96.2

20
81.6
74.1
20

1P
24.6
20
43.8

40.2

3EB
8
30.2

X
12 B 12 B 12 B 12 B 12 B

4 x Ø 4.5 SI unit 12.3


(For mounting) 1/4
5 L2 18
[1(P), 5(EA), 3(EB) port] M5 x 0.8 (External pilot)
(L5) L1 28
[External pilot port]
34

∗: These figures show the “SS5Y5-50S5-05B-02”.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 123 135.5 148 173 185.5 210.5 223 235.5 260.5 273 298
L4 112.5 125 137.5 162.5 175 200 212.5 225 250 262.5 287.5
L5 17.5 15 12.5 16 13.5 17.5 15 12.5 16 13.5 17.5

280
SY3000/5000/7000 Series
Plug-in Type 50/Side Ported

Dimensions: SY7000 Series Metal Base EX510

U 02
SS5Y7-50(R)S5- Stations D - KC
C, N (D)
, KN B

(Station 1) (Station n) 50RS5- Stations UD

(Slide locking manual override)


3
[Plug for external pilot]

78.3
78.1

84
2B 2B 2B

44.5
9.4
32.4
4A 4A 4A

(For DIN rail


10.8

10
(Pitch)

mounting)
∗ The above drawing shows when P,

14.3
46.6 P = 19
E port entry is D.
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
∗: These figures show the “SS5Y7-50S5-05B-C10”.
D side U side
L3
5.3 L4 Manual override
(DIN rail mounting hole pitch: 12.5)
(Pitch) (
Push-turn locking slotted type:
Press, then rotate it. )
DIN rail holding screw 52 P = 19 4(A) port side : Blue (For rubber seal)
(For DIN rail mounting) 20.5 19.6 (Light/surge voltage : Grey (For metal seal) M5 x 0.8 (External pilot)
suppressor) 2(B) port side : Yellow PE: Pilot EXH port
DIN rail bracket mounting screw
(For DIN rail mounting)

(DIN rail)
BA BA BA BA B A
5.5

PE
14 A 14 A 14 A 14 A 14 A

5EA
116.7

23.8
28
35

102.1
133.2

92.1
84.6
24

1P
23.8
28.2
49.7

44.1

3EB
8

X
32.1

12 B 12 B 12 B 12 B 12 B
NC
NC

4 x Ø 4.5
SI unit
(5.4)

(For mounting) 18.1


5 L2 20.9 M5 x 0.8 (External pilot)
(L5) L1 34.5 X: External pilot port
40.5
3/8
[1(P), 5(EA), 3(EB) port]

Port size 02 One-touch fitting (Replaceable)

2B 2B
44.5

44.5
10.3
9.4
32.4

31.5

4A 4A

10.8 (Pitch) (Pitch)


46.6 P = 19 55.7 P = 19
(11)
One-touch fitting
(22.9) [4(A), 2(B) port]
1/4 (For Ø 12) Applicable tube O.D.: Ø 6, Ø 1/4"
[4(A), 2(B) port] : Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
: Ø 12

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 123 148 160.5 185.5 198 223 235.5 260.5 273 298 310.5
L4 112.5 137.5 150 175 187.5 212.5 225 250 262.5 287.5 300
L5 15.5 18.5 15.5 18.5 15 18 15 18 14.5 17.5 14.5
281
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 51/Bottom Ported

Dimensions: SY3000 Series Metal Base EX510

M5, 01
SS5Y3-51S5- Stations D- CKC, N, 
KN

(Pitch)
46.4 P = 10.5
4 x M4 x 0.7, thread depth 4 One-touch fitting
23.6
(For mounting) [4(A), 2(B) port]
Applicable tube O.D.: Ø 2

21.1
29.8

3EB 2B 2B
: Ø 3.2, Ø 1/8"
16.8 16.8

: Ø 4, Ø 5/32"

56.4
1P

: Ø 6, Ø 1/4"
Cut dimensions for panel mounting 5EA 4A 4A

Refer to panel cut dimensions for details. Panel fitting dimensions

C2, C3, C4 : 16
: 15
1/8

16 17.8 (For 9 stations or more)


[1(P), 5(EA), 3(EB) port]
2 x Ø 4.5
2 x M4 x 0.7 L3

C6

4
(For 9 stations or more)
(For 9 stations or more) L2
40
(For 9 stations or more)

manual override)
(Slide locking
4 x Ø 4.5

52.4
68.3

56.4
65.6

62.6

4 x M4 x 0.7
32

4 x Ø 4.5
4 4
(4.1)

(Station 1) ---(Station n) L3
L2

(Pitch)
45.1 P = 10.5 Manual override ∗: These figures show the
D side U side
18.5 19.6 Light/surge voltage
suppressor (Push-turn locking slotted type:
Press, then rotate it. ) “SS5Y3-51S5-05D-C6”.

4(A) port side: Blue (For rubber seal)


4 x Ø 4.5 : Grey (For metal seal)
(For mounting) 2(B) port side: Yellow

B A B A B A B A B A
92.7
89

14 A 14 A 14 A 14 A 14 A
64.4
56.9
21.8 16

12 B 12 B 12 B 12 B 12 B

SI unit
(Max. 3) L1

Port size M5 Port size 01 One-touch fitting (Replaceable)


(Pitch) (Pitch) (Pitch)
46.4 P = 10.5 46.4 P = 12.5 46.4 P = 10.5
17 20.1

17 20.1
14 21.1
29.8

29.8

29.8

3EB 2B 3EB 2B 3EB 2B

1P 1P 1P

5EA 4A 5EA 4A 5EA 4A

M5 x 0.8 1/8 One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: Ø 2
: Ø 3.2, Ø 1/8"
: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
32

32

32
)
C6: 12.8
N7: 16.6
(

Port Sizes M5, C, N, KC, KN Port Size 01


n: Stations 2 3 4 5 6 7 8 9 10 11 12 n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5 L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5 L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 — — — — — — — 68.5 73.8 79 84.3 L3 — — — — — — — 77.8 84 90.3 96.5

282
SY3000/5000/7000 Series
Plug-in Type 51/Bottom Ported

Dimensions: SY5000 Series Metal Base EX510

01, 02
SS5Y5-51S5- Stations D - CKC, N, 
KN

2 x M4 x 0.7
4 x M4 x 0.7, (For 9 stations or more)
50 (Pitch)
thread depth 5 P = 16
24
(For mounting) One-touch fitting
[4(A), 2(B) port]
3EB 2B 2B
40.2

Applicable tube O.D.: Ø 4, Ø 5/32"


∗: These figures show the
: Ø 6, Ø 1/4"
20

“SS5Y5-51S5-05D-C8”.

71.6
1P : Ø 8, Ø 5/16"
20

5EA 4A 4A

Cut dimensions for panel mounting


Refer to panel cut dimensions for details.
C4, C6 : 14.8
1/4 : 17.2
[1(P), 5(EA), 3(EB) port] Panel fitting dimensions
L3
L2 2 x Ø 4.5
C8

(For 9 stations or more)

5
(Station 1) ----------- (Station n)
4 x Ø 4.5

20 25.2
manual override)
(Slide locking

61.6
71.6
74.3
71.6

68.6

4 x M4 x 0.7
38

4 x Ø 4.5
5 5
L3
(4.9)

(Pitch) L2
50 P = 16
Light/surge U side Manual override
20.5 19.6
D side voltage suppressor
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
: Grey (For metal seal)
B A B A B A B A B A 2(B) port side : Yellow
14 A 14 A 14 A 14 A 14 A
106.2
116.6

81.6
74.1
20
30.2

12 B 12 B 12 B 12 B 12 B

4 x Ø 4.5
SI unit
(For mounting)
(Max. 3) L1
Port size 01 Port size 02 One-touch fitting (Replaceable)
(Pitch) (Pitch) (Pitch)
50 P = 16 50 P = 17.5 50 P = 16
17.5

14.5

3EB 2B
14.8

3EB 2B
9.7
40.2

40.2

40.2

3EB 2B

1P 1P 1P

5EA 4A 5EA 4A 5EA 4A

1/8 1/4 One-touch fitting


[4(A), 2(B) port] [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
38

38

38
(15.5)

Port Sizes 01, C, N, KC, KN Port Size 02


n: Stations 2 3 4 5 6 7 8 9 10 11 12 n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244 L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 74 90 106 122 138 154 170 186 202 218 234 L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 — — — — — — — 93 101 109 117 L3 — — — — — — — 100.5 109.3 118 126.8

283
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 51/Bottom Ported

Dimensions: SY7000 Series Metal Base EX510

02
SS5Y7-51S5- Stations D- CKC, N, 
KN
(D)
Port size 02 One-touch fitting (Replaceable)

4 x M4 x 0.7 thread depth 5

(For Ø 12)
(For mounting)

(29.5)
3/8
[1(P), 5(EA), 3(EB) port]
(Pitch) M4 x 0.7 thread depth 5
(Max. 3) 52 P = 19
(For 9 stations or more)
27
Fitting dimensions for panel mounting

(17.6)
5

Refer to panel fitting dimensions


for details.
33.1

2B 2B
46.1

3EB
23
81.1

One-touch fitting
22

1P
[4(A), 2(B) port]
23

Applicable tube O.D.: Ø 6, Ø 1/4"


5EA 4A 4A 1/4 : Ø 8, Ø 5/16"
One-touch fitting [4(A), 2(B) port] : Ø 10, Ø 3/8"
[4(A), 2(B) port] : Ø 12
Applicable tube O.D. C8 : Ø 8

32.8
33.1
L3 C10: Ø 10 3EB 2B 3EB 2B

5 L2 N9 : Ø 5/16"
N11: Ø 3/8"

22.6
22
L1 1P 1P

5EA 4A 5EA 4A

(Station 1) (Station n)
(Slide locking manual override)

Panel fitting dimensions


78.3
78.1

4 x Ø 4.5 2 x Ø 4.5
84

(For 9 stations or more)


44.5

27.1
(5.4)

81.1
72.1

24

4 x M4 x 0.7
4 x Ø 4.5
5 5
D side U side L3
Manual override
L2
(Light/surge voltage suppressor) (
Push-turn locking slotted type:
Press, then rotate it. )
(Pitch) 4(A) port side : Blue (For rubber seal)
52 P = 19 : Grey (For metal seal)
20.5 19.6 2(B) port side : Yellow

B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
116.7
133.2

92.1
84.6
24
32.1

12 B 12 B 12 B 12 B 12 B
NC
NC

SI unit 4 x Ø 4.5
(For mounting)

∗: These figures show the “SS5Y7-51S5-05D-C10”.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 — — — — — — — 107.5 117 126.5 136
284
Plug-in Metal Base EX510
Type 52
Top Ported
SY3000/5000/7000 Series ®

How to Order Manifolds

SS5Y 3 52 S5 05 D
q w e r t y u i
q Series r Wiring type t Valve stations
3 SY3000 — All double wiring∗1 Symbol Stations Note
5 SY5000 S All single wiring∗2 02 2 stations
All double


7 SY7000 ∗1 All double wiring: 2-position single, double, wiring
3-position, and 4-position valves can be used 08 8 stations
on all manifold stations. 02 2 stations
All single
∗2 All single wiring: Available only for the manifold


w Type which has 2-position single for all stations 12 12 stations
wiring

52 Note that 2-position double, 3-, or 4-position


Top ported ∗ This also includes the number of the blanking
valves cannot be used.
52R Top ported, External pilot plate assembly.
∗ If a mix of single and double wiring is required, it is
supplied as a special order.

e SI unit output polarity y P, E port entry


— Positive common U U side∗1
N Negative common D D side∗1
B Both sides
∗1 Plugs are mounted on the opposite side of
the selected ports.

How to Order Manifold Assembly


u Thread type
— Rc
Example (SS5Y3-52S5-) 00F G
2-position double (24 VDC) 00N NPT
2-position single (24 VDC) SY3230-5U1-C6 (1 set)
SY3130-5U1-C6 (3 sets) 00T NPTF
3-position closed
centre (24 VDC)
SY3330-5U1-C6 (1 set)
i Mounting
— Direct mounting
DIN rail mounting
D (With DIN rail)
DIN rail mounting
D0
ide (Without DIN rail)
Us
D3 For 3 stations Specify a length longer
s
n


tio

than that of the standard


ta
S

3 D12 For 12 stations rail.


2
1 ∗ Refer to page 319 for the fixation of DIN rail
Manifold base ide
(5 stations) Ds mounting type manifold.
SS5Y3-52S5-05D

SS5Y3-52S5-05D ······ 1 set (Type 52 5-station manifold base part no.)


∗SY3130-5U1-C6 ······· 3 sets (2-position single part no.)
∗SY3230-5U1-C6 ······· 1 set (2-position double part no.)
∗SY3330-5U1-C6 ······· 1 set (3-position closed centre part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
• For the valve arrangement, the valve closest to the D side is considered
the 1st station.
• Under the manifold part number, state the valves to be mounted in For details on the EX510 Gateway Type Serial Transmission
order starting with the 1st station as shown in the figure above. If the System, refer to the Web Catalogue and the Operation Manual.
arrangement becomes too complicated, specify the details on a Please download the Operation Manual via the SMC website,
manifold specification sheet. https://www.smc.eu

285
Plug-in Metal Base SY3000/5000/7000 Series

How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.

SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported

q Series u Coil type !1 A, B port size


3 SY3000 — Standard Thread piping
5 SY5000 T With power saving circuit (Continuous duty type) Symbol Port size Applicable series
7 SY7000 ∗ Be sure to select the power saving circuit M5 M5 x 0.8 SY3000
type if the valve is to be continuously 01 1/8 SY5000
energised for long periods of time.
w Type of actuation ∗ Be careful of the energising time when the
02 1/4 SY7000

1 Single power saving circuit is selected. Refer to page One-touch fitting (Metric)
2-position 316 for details. Symbol A, B port SY3000 SY5000 SY7000
2 Double
3 Closed centre C2 Ø2  — —
C3 
i Rated voltage
4 3-position Exhaust centre Ø 3.2 — —
5 Pressure centre C4 Ø4   —
5 24 VDC C6 Ø6   
A∗1 4-position N.C./N.C.
B∗1 dual N.O./N.O. C8 Ø8 —  

C∗1 3-port N.C./N.O. o Light/surge voltage suppressor C10
C12
Ø 10
Ø 12



— 
∗1 Only the rubber seal type is available and common specification
for the 4-position dual 3-port valve. One-touch fitting (Inch)
Surge voltage Common
Symbol With light Symbol A, B port SY3000 SY5000 SY7000
suppressor specification

e Seal type R —
Non-polar
N1
N3
Ø 1/8"
Ø 5/32" 




U 
0 Rubber seal N7 Ø 1/4"   
S — Positive
1 Metal seal  N9 Ø 5/16" —  
Z  common
NS — Negative N11 Ø 3/8" — — 
r Pilot type NZ  common
— Internal pilot ∗ For the non-polar type, be careful of surge
voltage intrusion.
!2 Thread type
R External pilot
— Rc
Refer to page 317 for details.
∗ Only “Z” and “NZ” types are available with a F G
t Back pressure check valve power saving circuit. Select “R,” “U,” “S,” or
“Z” for the valve when the SI unit output
N
T
NPT
NPTF
(Built-in valve type) polarity is — (positive common). Select “R,”
∗ Only — is available for M5.
— None “U,” “NS,” or “NZ” for the valve when the SI
H Built-in unit output polarity is N (negative common).
∗ Only the rubber seal type is available. !3 Type of mounting screw
∗ The back pressure check valve is not
available for the 3-position type or the
!0 Manual override — Round head combination screw
B Hexagon socket head cap screw
SY7000. —: D:
Non-locking Push-turn K Round head combination screw (Drop prevention type)
y Pilot valve option push type locking H Hexagon socket head cap screw (Drop prevention type)
— Standard (0.7 MPa) slotted ∗ For “K” and “H,” the valve body cover has a
B Quick response type (0.7 MPa) type drop prevention construction to stop the
K∗1 High pressure type (1.0 MPa) mounting screws from falling out when the
valve is removed for maintenance, etc.
∗1 Only the metal seal type is available ∗ When ordering a valve individually, the
for the high pressure type. base gasket is not included.
E: F: Since the base gasket is attached to the
Push-turn Slide locking manifold, please order the base gasket
locking lever type separately if it is needed for maintenance.
type Refer to page 290 for base gasket and
mounting screw part numbers.
∗ “B” and “H” cannot be selected for the
individual SUP/EXH spacer assembly or
interface regulator.
∗ Refer to page 36 for the safety slide locking
manual override.

Protective class
class # (Mark: )
286
SY3000/5000/7000 Series
Plug-in Type 52/Top Ported

Dimensions: SY3000 Series Metal Base EX510

U
SS5Y3-52(R)S5- Stations D -(D)
B

52RS5- Stations UD
(Station 1)---(Station n)

N7: 80.6 )
76.8
[Plug for external pilot]

(For DIN rail


65.6
62.6

mounting)
(C6:
11.8
32
∗ The above drawing shows when P,

7.5
E port entry is D.

D side U side
L3
DIN rail 5.3 L4
holding screw (DIN rail mounting hole pitch: 12.5) Manual override M5 x 0.8 (External pilot)
[Pilot EXH port]
(For DIN
rail mounting) 45.1
(Pitch)
P = 10.5 (
Push-turn locking slotted type:
Press, then rotate it. ) 68.3
18.5 19.6 Light/surge voltage 4(A) port side : Blue (For rubber seal) (Slide locking manual override)
DIN rail bracket : Grey (For metal seal)
mounting screw suppressor
2(B) port side : Yellow
(For DIN
rail mounting)
DIN rail

B A B A B A B A B A
92.7

4A 4A 4A 4A 4A

5EA
89

PE
16.8 17.2
15.9 16.2
79
5.5

64.4
35

56.9
21.8 16

1P
29.8

X
26.6

2B 2B 2B 2B 2B

3EB
4 x Ø 4.5 SI unit 8 8.6
(For mounting) One-touch fitting 14.5
4 L2
[4(A), 2(B) port]
(L5) L1 22.1
Applicable tube O.D.: Ø 2
: Ø 3.2, Ø 1/8" 28
M5 x 0.8
: Ø 4, Ø 5/32"
[4(A), 2(B) port] 1/8
: Ø 6, Ø 1/4"
[1(P), 5(EA), 3(EB) port]
M5 x 0.8 (External pilot)
[External pilot port]

∗: These figures show the “SS5Y3-52S5-05B”.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17

287
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 52/Top Ported

Dimensions: SY5000 Series Metal Base EX510

U
SS5Y5-52(R)S5- Stations D -(D)
B

(Station 1)----------- (Station n) 52RS5- Stations UD

(86.7)
[Plug for external pilot]
72.3
71.6

(For DIN rail


mounting)
14.3
38
∗ The above drawing shows when P,

10
E port entry is D.

D side U side
DIN rail L3
holding screw 5.3 L4
(For DIN M5 x 0.8 (External pilot)
(DIN rail mounting hole pitch: 12.5) Manual override
rail mounting) [Pilot EXH port]
(Pitch)
50 P = 16 (Push-turn locking slotted type:
Press, then rotate it. ) 74.3
DIN rail bracket 20.5 19.6 4(A) port side : Blue (For rubber seal) (Slide locking
mounting screw Light/surge voltage : Grey (For metal seal) manual override)
(For DIN suppressor 2(B) port side : Yellow 68.6
rail mounting)
01 : 16.2
C : 14.5

DIN rail
5.5

B A B A B A B A B A
4A 4A 4A 4A 4A

PE
5EA
106.2

23.2
116.6
35

96.2

20
81.6
74.1
20

1P
24.6
20
43.8
40.2

40.2

3EB
30.2

X
2B 2B 2B 2B 2B 8

1/8 12.3
4 x Ø 4.5 SI unit [4(A), 2(B) port] 18
(For mounting) One-touch fitting
5 L2 28
[4(A), 2(B) port]
(L5) L1 Applicable tube O.D.: Ø 4, Ø 5/32" 34
: Ø 6, Ø 1/4" 1/4
: Ø 8, Ø 5/16"
[1(P), 5(EA), 3(EB) port]
M5 x 0.8 (External pilot)
[External pilot port]

∗: These figures show the “SS5Y5-52S5-05B”.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5

288
SY3000/5000/7000 Series
Plug-in Type 52/Top Ported

Dimensions: SY7000 Series Metal Base EX510

U
SS5Y7-52(R)S5- Stations D -(D)
B

(Station 1) (Station n)
52RS5- Stations UD

(A, B port: Ø 12)


3

(110.3)
[Plug for external pilot]

(98.4)
87
78.1

44.5

(For DIN rail


10

mounting)
∗ The above drawing shows when P,
14.3 E port entry is D.

D side U side

L3
5.3 L4 Manual override
M5 x 0.8 (External pilot)
(DIN rail mounting hole pitch: 12.5)
(Push-turn locking slotted type:
Press, then rotate it. ) PE: Pilot EXH port
DIN rail holding screw (Pitch) 4(A) port side : Blue (For rubber seal)
52 P = 19 : Grey (For metal seal) 84
(For DIN rail mounting)
(Light/surge voltage 2(B) port side : Yellow (Slide locking 78.3
20.5 19.6 manual override)
DIN rail bracket mounting screw suppressor)
(For DIN rail mounting)

(DIN rail) B A B A B A B A B A
5.5

PE
4 A 4 A 4 A 4 A 4 A

5EA
116.7

23.8
28
102.1
35

133.2

92.1
84.6
24

1P
23.8
28.2
49.7
45.6

44.1
22.6

3EB

8
X
32.1

2B 2B 2B 2B 2B
NC
NC

4 x Ø 4.5 1/4 18.1


(For mounting) [4(A), 2(B) port] 20.9
5 L2 One-touch fitting 34.5
(L5) L1 [4(A), 2(B) port] 40.5
Applicable tube O.D. : Ø 6, Ø 1/4"
: Ø 8, Ø 5/16" 3/8
: Ø 10, Ø 3/8" [1(P), 5(EA), 3(EB) port]
: Ø 12
M5 x 0.8 (External pilot)
X: External pilot port

∗: These figures show the “SS5Y7-52S5-05B”.

n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 123 148 160.5 185.5 198 223 235.5 260.5 273 298 310.5
L4 112.5 137.5 150 175 187.5 212.5 225 250 262.5 287.5 300
L5 15.5 18.5 15.5 18.5 15 18 15 18 14.5 17.5 14.5

289
SY3000/5000/7000 Series Type 50, 51, 52
Plug-in Metal Base Manifold Exploded View

Tightening torque: 1.4 N·m

Tightening torque: 1.4 N·m w

Holding screw

e It is mounted only for the DIN rail


mounting type (with DIN rail).

r It is mounted only for the DIN rail mounting type.


(Tightening torque of holding screw: 1.4 N·m)
∗ Refer to page 319 for the fixation of DIN rail
Caution mounting type manifold.
Tightening torque
M2: 0.16 N·m (SY3000)
M3: 0.8 N·m (SY5000/7000)

Manifold Parts Nos.

Part no.
No. Description Note
SY3000 SY5000 SY7000
Round head SY3000-23-24A SY5000-221-1A SY7000-221-1A
Part numbers shown on the left are
Valve mounting combination screw (M2 x 32) (M3 x 32.5) (M3 x 36.5)
q screw
for 10 valves (20 pcs.).
Hexagon socket SY3000-222-1A SY5000-222-1A SY7000-222-1A (30 pcs. for the SY7000)
head cap screw (M2 x 32) (M3 x 32.5) (M3 x 36.5)
Base gasket Part numbers shown on the left are
w SY30M-11-1A SY50M-11-1A SY70M-11-1A for 10 valves (10 pcs.).
(for plug-in metal base and sub-plate)
e DIN rail VZ1000-11-1- VZ1000-11-4- VZ1000-11-4- Refer to page 292.
Clamp bracket assembly Part numbers shown on the left are for the clamp bracket
r SY30M-15-2A SY50M-15-2A SY70M-15-2A assembly for one manifold (two sets of clamp brackets).
(for plug-in metal base)

290
SY3000/5000/7000 Series
One-touch Fitting, Plug Assembly Part Nos.
Refer to “How to Replace One-touch Fittings” on page 300 for the replacement method.

 One-touch fittings
Port size SY3000 SY5000 SY7000
Ø2 VVQ1000-50A-C2 — —
Ø 3.2 VVQ1000-50A-C3 — —
Metric size

Ø4 VVQ1000-50A-C4 VVQ1000-51A-C4 —
Ø6 Straight type VVQ1000-50A-C6 VVQ1000-51A-C6 VVQ2000-51A-C6
Ø8 — VVQ1000-51A-C8 VVQ2000-51A-C8
A, B port

Ø 10 — — VVQ2000-51A-C10
Ø 12 — — KQ2H12-17-X224
Ø 1/8" VVQ1000-50A-N1 — —
Inch size

Ø 5/32" VVQ1000-50A-N3 VVQ1000-51A-N3 —


Ø 1/4" Straight type VVQ1000-50A-N7 VVQ1000-51A-N7 VVQ2000-51A-N7
Ø 5/16" — VVQ1000-51A-N9 VVQ2000-51A-N9
Ø 3/8" — — VVQ2000-51A-N11
∗ Purchasing order is available in units of 10 pieces.

 Plug assembly
SY3000 SY5000 SY7000
A, B port VVQ0000-58A VVQ1000-58A VVQ2000-58A
∗ Purchasing order is available in units of 10 pieces.

291
SY3000/5000/7000 Series
Manifold Options
 For the SY3000 Plug-in metal base
VZ1000-11-1-
∗ After confirming the L3 dimension in the dimensions table of each series, refer to the DIN rail dimensions table below and
specify the number in the box .
L
(7.5) 8

5.5
(35)
(25)

Rail mounting hole pitch 12.5

No. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
L dimension 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 273 285.5 298 310.5 323
Weight [g] 17.6 19.9 22.1 24.4 26.6 28.9 31.1 33.4 35.6 37.9 40.1 42.4 44.6 46.9 49.1 51.4 53.6 55.9 58.1
No. 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
L dimension 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 523 535.5 548 560.5
Weight [g] 60.4 62.5 64.9 67.1 69.4 71.6 73.9 76.1 78.4 80.6 82.9 85.1 87.4 89.6 91.9 94.1 96.4 98.6 100.9
No. 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56
L dimension 573 585.5 598 610.5 623 635.5 648 660.5 673 685.5 698 710.5 723 735.5 748 760.5 773 785.5 798
Weight [g] 103.1 105.4 107.6 109.9 112.1 114.4 116.6 118.9 121.1 123.4 125.6 127.9 130.1 132.4 134.6 136.9 139.1 141.4 143.6
No. 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71
L dimension 810.5 823 835.5 848 860.5 873 885.5 898 910.5 923 935.5 948 960.5 973 985.5
Weight [g] 145.9 148.1 150.4 152.6 154.9 157.1 159.4 161.6 163.9 166.1 168.4 170.6 172.9 175.1 177.4

 For the SY5000/7000 Plug-in metal base


VZ1000-11-4-
∗ After confirming the L3 dimension in the dimensions table of each series, refer to the DIN rail dimensions table below and
specify the number in the box .
L
8
5.5
(35)
(25)

(10) Rail mounting hole pitch 12.5

No. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
L dimension 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 273 285.5 298 310.5 323
Weight [g] 24.8 28 31.1 34.3 37.4 40.6 43.8 46.9 50.1 53.3 56.4 59.6 62.7 65.9 69.1 72.2 75.4 78.6 81.7
No. 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
L dimension 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 523 535.5 548 560.5
Weight [g] 84.9 88 91.2 94.4 97.5 100.7 103.9 107 110.2 113.3 116.5 119.7 122.8 126 129.2 132.3 135.5 138.6 141.8
No. 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56
L dimension 573 585.5 598 610.5 623 635.5 648 660.5 673 685.5 698 710.5 723 735.5 748 760.5 773 785.5 798
Weight [g] 145 148.1 151.3 154.5 157.6 160.8 163.9 167.1 170.3 173.4 176.6 179.8 182.9 186.1 189.2 192.4 195.6 198.7 201.9
No. 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71
L dimension 810.5 823 835.5 848 860.5 873 885.5 898 910.5 923 935.5 948 960.5 973 985.5
Weight [g] 205.1 208.2 211.4 214.5 217.7 220.9 224 227.2 230.4 233.5 236.7 239.8 243 246.2 249.3

292
SY3000/5000/7000 Series

Manifold Options
 Blanking plate assembly (With mounting screw)
Used when valve additions are expected or for maintenance
A structure is in place on the blanking plate to prevent the mounting screws from sliding.

SY30M-26-2A (-B) SY50M-26-2A (-B) SY70M-26-2A (-B)

Refer to pages 300 to 302 for dimensions.


Refer to pages 294 to 299 for individual SUP/EXH and other options. Part numbers of mounting screw [Hexagon bolt]
(For repairs)
SY3000: SY3000-23-24A [SY3000-222-1A]
SY5000: SY5000-221-1A [SY5000-222-1A]
SY7000: SY7000-221-2A [SY7000-222-1A]
How to Order Blanking Plate Assembly

SY 0M 26 2 A
Series
3 SY3000 Option for mounting
5 SY5000 With mounting screw

7 SY7000 (Round head combination screw)
With mounting screw
B (Hexagon socket head cap screw)
(A) (B)
4 2 Base type
2 For plug-in metal base

5 1 3
(EA) (P) (EB)
Circuit diagram

 Plug Dimensions
These are inserted in unused cylinder Applicable fitting size Applicable fitting size
Ø d (Metric size)
Model A L ØD
Ø d (Inch size)
Model A L ØD
ports and P, E ports.
Ød

2 KJP-02 8.2 17 3 1/8" KQ2P-01 16 31.5 5


3.2 KQ2P-23 16 31.5 5 5/32" KQ2P-03 16 32 6
ØD

4 KQ2P-04 16 32 6 1/4" KQ2P-07 18 35 8.5


A 6 KQ2P-06 18 35 8 5/16" KQ2P-09 20.5 39 10
L 8 KQ2P-08 20.5 39 10 3/8" KQ2P-11 22 43 11.5
10 KQ2P-10 22 43 12
∗ Shipped together with the product 12 KQ2P-12 24 45.5 14

293
Manifold Options SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options ∗ Refer to pages 300 to 302 for dimensions. M3: 0.8 N·m (SY5000/7000)

 Individual SUP spacer assembly How to Order Individual SUP/EXH Spacer Assembly
[With a connector gasket, a base gasket, and two mounting One-touch fitting
screws (3 pcs. for the SY7000)] Straight type SY 3 0M 38 1 A C6
When the same manifold is used for different pressures, an
individual SUP spacer assembly is used as a supply port for One-touch fitting
different pressures. Elbow type SY 3 0M 38 2 A L6
∗ When selecting a One-touch fitting elbow type for a spacer Series
assembly, use it faced upward, since it interferes with A and B
port piping of Type 50 manifolds. 3 SY3000
5 SY5000
7 SY7000

4(A) Spacer type


2-position single valve 2(B)
Individual SUP spacer 38 Individual SUP spacer
assembly 39 Individual EXH spacer
1(P')
Mounting
screw 5(EA) Individual SUP/EXH spacer assembly
1(P)
3(EB) 2 Short elbow type
Circuit diagram 3 Long elbow type
Base gasket
(Mounting example of a ∗ Select the long elbow type for a
2-position single valve)
3-position valve.
Part numbers of mounting
screw (For repairs) Port size (Metric/One-touch fittings)
SY3000: SY3000-23-12A (2 pcs.) Symbol P, E port SY3000 SY5000 SY7000
SY5000: SY5000-221-2A (2 pcs.) L4 Ø4   —
Connector gasket SY7000: SY7000-221-2A (3 pcs.) L6 Ø6   
L8 Ø8 —  
L10 Ø 10 — — 
L12 Ø 12 — — 
 Individual EXH spacer assembly
Port size (Inch/One-touch fittings)
[With a connector gasket, a base gasket, and two mounting
Symbol P, E port SY3000 SY5000 SY7000
screws (3 pcs. for the SY7000)]
LN3 Ø 5/32"  — —
When valve exhaust affects other stations due to the circuit LN7 Ø 1/4"   —
configuration, this spacer assembly is used for individual valve
LN9 Ø 5/16" —  —
exhaust.
LN11 Ø 3/8" — — 
∗ When selecting a One-touch fitting elbow type for a spacer
assembly, use it faced upward, since it interferes with A and B
port piping of Type 50 manifolds. Port size (Metric/One-touch fittings)
Symbol P, E port SY3000 SY5000 SY7000
C2 Ø2  — —
4(A) C3 Ø 3.2  — —
2-position single valve 2(B) C4 Ø4   —
Individual EXH spacer
assembly C6 Ø6   
3/5(E') C8 Ø8 —  
Mounting C10 Ø 10 — — 
screw 5(EA)
1(P) C12 Ø 12 — — 
3(EB)
Circuit diagram Port size (Inch/One-touch fittings)
Base gasket (Mounting example of a Symbol P, E port SY3000 SY5000 SY7000
2-position single valve) N1 Ø 1/8"  — —
N3 Ø 5/32"   —
Part numbers of mounting N7 Ø 1/4"   
screw (For repairs)
N9 Ø 5/16" —  
SY3000: SY3000-23-12A (2 pcs.) N11 Ø 3/8" — — 
SY5000: SY5000-221-2A (2 pcs.)
SY7000: SY7000-221-2A (3 pcs.) ∗ When using in combination with the SY 57 30 01 -1-E (With
Connector gasket
residual pressure release valve), the length of the required
mounting screws will differ. Please contact SMC for details.

294
SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options ∗ Refer to pages 300 to 302 for dimensions. M3: 0.8 N·m (SY5000/7000)

 SUP stop valve spacer assembly with residual


pressure release valve
[With a connector gasket, a base gasket, and two mounting screws
(3 pcs. for the SY7000)]
It is used to shut off the supply air to valves individually.
2-position single valve
4(A)
SY 3 0M 50 1A E 2(B)

Series Manual override


3 SY3000 Push-turn Base gasket
EXH.
5 SY5000 — locking 5(EA)
1(P) Mounting screw
7 SY7000 slotted type 3(EB) Connector gasket
Push-turn SUP stop valve spacer assembly
with residual pressure release valve
E locking
lever type Circuit diagram Part numbers of mounting
(Mounting example of a 2-position single valve) screw (For repairs)
SY3000: SY30M-56-1A (2 pcs.)
SY5000: SY50M-56-1A (2 pcs.)
SY7000: SY70M-56-1A (3 pcs.)
∗ For lever type
When locking the lever type manual override, push the lever down in the
PUSH position with your fingers until it stops, then turn the lever 90° clockwise.
(PUSH J LOCK)
Turning the lever without pushing it down until it stops can cause damage to
the manual override and other problems such as air leakages.
To unlock the manual override, turn the lever counterclockwise. (LOCK J PUSH)

[How to mount SUP stop valve spacer assembly with residual Valve mounting screw (See page 198.)
Tightening torque:
pressure release valve] SY3000 series: 0.16 N·m
Insert the SUP stop valve mounting screw from the side of the spacer assembly, SY5000/7000 series: 0.8 N·m
and mount it to the manifold. For Hexagon socket head cap screws
Tighten the SUP stop valve mounting screw to the specified tightening torque. Nominal wrench size:
Mount the valve and tighten the valve mounting screws to the specified SY3000 series: 1.5
tightening torque after mounting the SUP stop valve spacer assembly with SY5000/7000 series: 2.5 Valve
residual pressure exhaust valve.
SUP stop valve spacer assembly
∗ Install the plate type nut to the spacer assembly as shown in the figure if it with residual pressure release valve
comes off. The SUP stop valve mounting screws can be tightened with a Plate type nut
hexagon wrench without removing the plate type nut. SY3000 series:
∗ This product is only for internal pilot specifications, as the external pilot air SY30M-57-1A (10 pcs. included) Hexagon wrench
cannot be shut off. SY5000/7000 series: Nominal wrench size:
∗ If the product is equipped with a 3-position closed centre, residual pressure SY50M-57-1A (10 pcs. included) SY3000 series: 1.3
cannot be released, so use in combination with a 3-port valve, which can be SY5000/7000 series: 2
SUP stop valve mounting screw
connected to the A, B piping port.
Tightening torque:
SY3000 series: 0.16 N·m
SY5000/7000 series: 0.8 N·m

295
Manifold Options SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options ∗ Refer to pages 300 to 302 for dimensions. M3: 0.8 N·m (SY5000/7000)

 Double check spacer assembly with residual pressure release <Example>


valve (Side/Bottom ported) Double check spacer assembly
with residual pressure release valve
[With a connector gasket, a base gasket, and two mounting screws (3 pcs. for the SY7000)]
3-position exhaust centre valve
It is used to hold the intermediate position of the cylinder for a long period of time. Use a
3-position exhaust centre valve when the double check spacer assembly with residual ex-
haust valve is used.
It can also be used for drop prevention at the cylinder stroke end when supply residual
pressure is released by using a 2-position single/double valve.

Series Part no. Intermediate stop Drop prevention


SY3000 SY30M-60-1A 3 3
Applicable valve SY 5 40 01 SY 5 12 001
SY5000 SY50M-60-1A 7 7 4(A) 2(B) EXH.
SY7000 SY70M-60-1A 5(EA)
1(P)
3(EB)
Circuit diagram
(Intermediate stop: When 3-position exhaust centre valve
is mounted)
Mounting Double check spacer assembly
screw with residual pressure release valve
2-position single valve

Part numbers of mounting


screw (For repairs)
4(A) 2(B) EXH.
Base gasket SY3000: SY3000-23-27A (2 pcs.) 5(EA)
SY5000: SY5000-221-4A (2 pcs.) 1(P)
SY7000: SY7000-221-4A (3 pcs.) 3(EB)
Circuit diagram
(Drop prevention: When 2-position single valve
is mounted)
Caution
• Air leakage from the pipe between the valve and cylinder or from the fittings will prevent the cylinder from
Connector gasket stopping for a long period of time. Check the leakage using neutral household detergent, such as dish
washing soap. Also, check the cylinder’s tube gasket, piston seal, and rod seal for air leakage.
• Combining with 3-position closed centre or pressure centre valve will not work.
• If the exhaust of the double check spacer is restricted too much, the cylinder may not operate properly
and may not stop intermediately.
• Set the cylinder load so that the cylinder pressure will be within two times that of the supply pressure.
• If using a double check spacer that is built in to the sub-plate, refer to page 307.

Specifications
Max. operating pressure 1.0 MPa
Min. operating pressure 0.1 MPa
Ambient and fluid temperatures –10 to 50 °C
SY3000 0.3 dm3/(s·bar)
Flow rate
characteristics: C
SY5000 0.7 dm3/(s·bar)
SY7000 1.1 dm3/(s·bar)
Max. operating frequency 3 Hz

296
SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options ∗ Refer to pages 300 to 302 for dimensions. M3: 0.8 N·m (SY5000/7000)

 Interface regulator
[With a connector gasket, a base gasket, and two mounting screws (3 pcs. for the SY7000)]
Used when the supply pressure for each valve on the same manifold must be individually set (reduced pressure)
How to Order

SY 3 0M 05 P
Series Applicable valve∗3
3 SY3000 — For single, double, and 4-position
3 For 3-position
Pressure gauge option∗1 ∗1 In the case of the SY3000 series with a pressure gauge, when mounting on the manifold, use
M1 Without pressure gauge caution that the part numbers are different between the odd no. stations and the even no. stations
05 Pressure gauge with MPa display (For odd number station) to prevent the pressure gauges from interfering with each other.
06 Pressure gauge with MPa display (For even number station) ∗2 As per the new Measurement Law, gauges with a psi display will only be sold to overseas
customers.
N5 Pressure gauge with psi display (For odd number station)∗2
∗3 In the case of the SY3000 series, use caution that the part numbers will differ depending on the
N6 Pressure gauge with psi display (For even number station)∗2 one for single/double and 4- and 3-position due to the different length of solenoid valves. Also, if
you have selected a model with a pressure gauge, and if at least the one for 3-position is included
in the same manifold, use all the ones for 3-position to prevent the pressure gauges from
SY 5 0M 00 P interfering with each other.

Series Regulating port


5 SY5000 P 1(P) port
7 SY7000 A1 4(A) port (P controlled type, A port regulation)
B1 2(B) port (P controlled type, B port regulation) Part numbers of mounting
Pressure gauge option screw (For repairs)
M1 Without pressure gauge SY3000: SY3000-23-12A (2 pcs.)
00 Pressure gauge with MPa display SY5000: SY5000-221-6A (2 pcs.)
N0 Pressure gauge with psi display∗2 SY7000: SY7000-221-6A (3 pcs.)

Mounting screw

Base gasket

Connector gasket

SY30M-05/N5- SY30M-06/N6- SY30M-M1- SY50M-00/N0- SY50M-M1- SY70M-00/N0- SY70M-M1-


(With pressure gauge/ (With pressure gauge/ (Without pressure gauge) (With pressure gauge) (Without pressure gauge) (With pressure gauge) (Without pressure gauge)
For odd number station) For even number station)

Specifications

Interface regulator model SY30M--- SY50M-- SY70M-- ∗1 3-position closed centre and pressure centre, and 4-position
Applicable valve model∗1 SY3 03 (R) SY5 03 (R) SY7 03 (R) dual 3-port valves are only available for 1(P) port pressure
regulation.
Regulating port 1(P), 4(A), 2(B)
∗2 Gasket and mounting screws are included in the weight.
Set pressure range 0.1 to 0.7 MPa ∗3 ( ): Denotes the values of SY30M---3
Maximum operating pressure 1.0 MPa ∗ Always apply pressure from 1(P) port in the base for interface
Fluid Air regulator.
Ambient and fluid temperatures –10 to 50 °C (No freezing) ∗ When using in combination with the SY 57 30 01 -1-E (With
With pressure gauge 33 (35)∗3 75 93 residual pressure release valve), the length of the required
Weight [g]∗2 mounting screws will differ. Please contact SMC for details.
Without pressure gauge 27 (29)∗3 69 87

Symbol (A)4 2(B)


(A)4 2(B)
2(B) (A)4

(EA)5 3(EB)
(EA)5 3(EB) (EA)5 3(EB)

1 4(A) port regulation 2(B) port regulation


1(P) port regulation (P) 1 1
(P controlled type, A port regulation) (P) (P controlled type, B port regulation) (P)

297
Manifold Options SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options: Spacer Combinations and Screw List q M3: 0.8 N·m (SY5000/7000)

q
q SY3000 (M2) w
w SY5000 (M3) e
e SY7000 (M3)
Combination
Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw

<Round head combination screw> SY3000- SY3000- SY5000- SY5000- SY7000- SY7000-
q: SY3000-23-24A A Valve 23-24A 222-1A 221-1A 222-1A 221-1A 222-1A
[for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves
w: SY5000-221-1A
(20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)] (30 pcs.)] (30 pcs.)]
e: SY7000-221-1A
<Hexagon socket head cap screw> SUP stop valve
A q: SY3000-222-1A spacer assembly
w: SY5000-222-1A B with residual
B e: SY7000-221-1A pressure
release valve SY30M-56-2A SY50M-56-2A SY70M-56-2A
q: SY30M-56-2A
C (2 pcs.) (2 pcs.) (3 pcs.)
w: SY50M-56-2A Individual
e: SY70M-56-2A SUP (EXH)
C
spacer
assembly

A Valve
<Round head combination screw>
q: SY3000-23-33A
w: SY5000-221-5A Double check
A e: SY7000-221-5A spacer assembly SY3000- SY5000- SY7000-
B with residual 23-33A — 221-5A — 221-5A —
B pressure release (2 pcs.) (2 pcs.) (3 pcs.)
valve
C Individual
SUP (EXH)
C
spacer
assembly

A Valve
<Round head combination screw>
q: SY3000-23-32A
w: SY5000-221-3A
A Individual
e: SY7000-221-3A SUP (EXH)
SY3000- SY5000- SY7000-
B 23-32A — 221-3A — 221-3A —
B spacer
(2 pcs.) (2 pcs.) (3 pcs.)
assembly

C Individual
EXH (SUP)
C
spacer
assembly

SY3000- SY3000- SY5000- SY5000- SY7000- SY7000-


A Valve 23-24A 222-1A 221-1A 222-1A 221-1A 222-1A
<Round head combination screw> [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves
(20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)] (30 pcs.)] (30 pcs.)]
q: SY3000-23-24A
w: SY5000-221-1A SUP stop valve
e: SY7000-221-1A spacer assembly
<Hexagon socket head cap screw> B with residual
A q: SY3000-222-1A pressure
w: SY5000-222-1A release valve
B e: SY7000-222-1A
Individual
C SUP (EXH) SY30M-56-4A SY50M-56-4A SY70M-56-4A
C
spacer (2 pcs.) (2 pcs.) (3 pcs.)
q: SY30M-56-4A
D assembly
w: SY50M-56-4A
e: SY70M-56-4A
Individual
EXH (SUP)
D
spacer
assembly

∗ Mounting onto a manifold follows the order explained above.


∗ The fitting for individual SUP/EXH spacers comes in a straight type only, since an elbow type would interfere with each spacer assembly when laminated.

298
SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options: Spacer Combinations and Screw List w M3: 0.8 N·m (SY5000/7000)

q
q SY3000 (M2) w
w SY5000 (M3) e
e SY7000 (M3)
Combination
Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw

<Round head combination screw> SY3000- SY3000- SY5000- SY5000- SY7000- SY7000-
q: SY3000-23-24A A Valve 23-24A 222-1A 221-1A 222-1A 221-1A 222-1A
w: SY5000-221-1A [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves
e: SY7000-221-1A (20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)] (30 pcs.)] (30 pcs.)]
<Hexagon socket head cap screw> SUP stop valve
q: SY3000-222-1A spacer assembly
A
w: SY5000-222-1A B with residual
e: SY7000-222-1A pressure
B
release valve SY30M-56-3A SY50M-56-3A SY70M-56-3A
q: SY30M-56-3A Double check (2 pcs.) (2 pcs.) (3 pcs.)
C w: SY50M-56-3A spacer
e: SY70M-56-3A C assembly with
residual pressure
release valve

SY3000- SY3000- SY5000- SY5000- SY7000- SY7000-


23-24A 222-1A 221-1A 222-1A 221-1A 222-1A
<Round head combination screw> A Valve
[for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves
q: SY3000-23-24A (20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)] (30 pcs.)] (30 pcs.)]
w: SY5000-221-1A
e: SY7000-221-1A SUP stop valve
spacer assembly
<Hexagon socket head cap screw>
q: SY3000-222-1A B with residual
A w: SY5000-222-1A pressure
e: SY7000-222-1A release valve
B Double check
q: SY30M-56-5A spacer assembly
C SY30M-56-5A SY50M-56-5A SY70M-56-5A
w: SY50M-56-5A C with residual
(2 pcs.) (2 pcs.) (3 pcs.)
pressure release
e: SY70M-56-5A
D valve

Individual
EXH (SUP)
D
spacer
assembly

A Valve
<Round head combination screw>
q: SY3000-23-32A
A w: SY5000-221-7A
e: SY7000-221-7A SY3000- SY5000- SY7000-
Interface
B 23-32A — 221-7A — 221-7A —
B regulator
(2 pcs.) (2 pcs.) (3 pcs.)

C
Individual
SUP (EXH)
C
spacer
assembly

∗ Mounting onto a manifold follows the order explained above.


∗ The fitting for individual SUP/EXH spacers comes in a straight type only, since an elbow type would interfere with each spacer assembly when laminated.
∗ When laminating an interface regulator with other options, only the combinations in the table above are possible.

299
Manifold Options SY3000/5000/7000 Series

Dimensions: Manifold Options/SY3000 Series


 Blanking plate assembly  Individual SUP/EXH spacer  Double check spacer
assembly (Top/Bottom assembly with residual
ported) pressure release valve

)
C6: 91.8
N7: 95.6
62.6

)
LN7: 63.3
L6: 60.8
2B B A B A
14 A 14 A

89
(

112.8
4A

(
12 B 12 B

LOCK
PUSH

B A B A B A

92.7
4A 4A
89
101.2

14 A
89

111.6
2B 2B

83.6
12 B

2B
7.2

4A
13.9

<Type 50, 51, 52>


One-touch fitting
(SUP port, EXH port)
Applicable tubing O.D.: Ø 4, Ø 5/32"
Applicable tubing O.D.: Ø 6, Ø 1/4"
<Type 50, 51>

<Type 51, 52>

 Individual SUP/EXH spacer  SUP stop valve spacer  Interface regulator


assembly (Side ported) assembly with residual
pressure release valve

One-touch fitting
(SUP port, EXH port)
(100.7)

Applicable tubing O.D.: Ø 2 B A B A B A B A


92.2

(111.7)
89

14 A 14 A 14 A 14 A
103.2

(118.3)

Applicable tubing O.D.: Ø 3.2, Ø 1/8"


109.8

B A B A
Applicable tubing O.D.: Ø 4, Ø 5/32" 14 A 14 A
89
101.2

Applicable tubing O.D.: Ø 6, Ø 1/4"


12 B 12 B 12 B 12 B

12 B 12 B

1 P
77.6

LOCK

PUSH

2B
(2)

Max. 14
39

05
4A
SY30M- N5 --
06
SY30M- N6 --
SY30M-M1--
77.6
(58.7)

2B
B A B A
14 A 14 A
89

77.6
76.9

4A
62.1

2B
39.9

12 B 12 B
4A
(3.9)

<Type 50, 51, 52>

<Type 50, 51, 52>


<Type 50>
∗ The dimensions within ( ) apply to the ∗ The dimensions within ( ) apply to the
SY30M-50-1AE. SY30M---3.
300
SY3000/5000/7000 Series

Dimensions: Manifold Options/SY5000 Series


 Blanking plate assembly  Individual SUP/EXH spacer  Double check spacer
assembly (Top/Bottom assembly with residual
68.6 ported) pressure release valve

2B

(104.2)

96.6
4A

(72.2)
2B

4A

BA
14 A

B A B A
81.6

14 A 14 A

106.2
BA BA
4A 4A
106.2

116.6

138.6
126.4

142.4
12 B

12 B 12 B
2B 2B

<Type 50, 51, 52> PUSH


LOCK
12.6

18.2

<Type 50, 51>


One-touch fitting
(SUP port, EXH port)
Applicable tubing O.D.: Ø 4
: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"

<Type 51, 52>

 Individual SUP/EXH spacer  SUP stop valve spacer  Interface regulator


assembly (Side ported) assembly with residual
pressure release valve

One-touch fitting
(SUP port, EXH port)
Applicable tubing O.D.: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
86.1
(73.6)

: Ø 8, Ø 5/16"
91.6
87.8
74.5

2B
2B
50

4A
4A

1 P
86.1

2B
47

4A

BA BA BA
106.2

B A B A 14 A 14 A 14 A
14 A 14 A
106.2

127.5
127.7

145.5

12 B 12 B 12 B
12 B 12 B

BA BA
14 A 14 A
106.2

LOCK

PUSH
(3)

12 B 12 B
Max. 21

<Type 50, 51, 52>


00
SY50M- N0 -
∗ The dimensions within ( ) apply to the SY50M-M1-
<Type 50> SY50M-50-1AE.
<Type 50, 51, 52>

301
Manifold Options SY3000/5000/7000 Series

Dimensions: Manifold Options/SY7000 Series


 Blanking plate assembly  Individual SUP/EXH spacer  Double check spacer assembly
assembly (Top/Bottom ported) with residual pressure release valve
78.3

2B

(119.3)

113.1
4A

(81.4)
2B

4A

B A
14 A
92.1

B A B A B A B A

4A 4A 14 A 14 A

116.7
116.7

116.7
145.1

12 B

164.1

167.1
2B 2B 12 B 12 B
19.2

<Type 50, 51, 52>


38.2

PUSH LOCK

One-touch fitting
(SUP port, EXH port) <Type 50, 51>
Applicable tubing O.D.: Ø 6, Ø 3/8"
:Ø8
Ø 10
<Type 51, 52>

 Individual SUP/EXH spacer  SUP stop valve spacer assembly  Interface regulator
assembly (Side ported) with residual pressure release valve
One-touch fitting
(SUP port, EXH port)
Applicable tubing O.D.: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16" 101.3
94.3

: Ø 10, Ø 3/8"
81

: Ø 12
99.1

2B
56.5
(85)

2B
4A

4A

1 P
99.1

2B
55

4A
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
116.7
116.7

143.8
148.7

161.8

12 B 12 B 12 B 12 B 12 B

B A B A
14 A 14 A
116.7

PUSH LOCK
(2)
(9.6)

12 B 12 B
Max. 21

00
SY70M- N0 -
<Type 50, 51, 52> SY70M-M1-
(For Ø 12)
(21.5)

∗ The dimensions within ( ) apply to the


SY70M-50-1AE.
<Type 50, 51, 52>

<Type 50>
302
303
Plug-in Sub-plate Type
[IP67 Compliant]

304
SY3000/5000/7000 Series
Plug-in Single Unit/Sub-plate Type [IP67 Compliant] ®

(Side ported, Bottom ported, Top ported) RoHS

Plug-in Sub-plate Specifications


Manifold type Plug-in sub-plate
Side ported 1(P), 5(EA)/3(EB) port, 4(A)/2(B) port Side ported
Bottom ported 1(P), 5(EA)/3(EB) port, 4(A)/2(B) port Bottom ported
Piping direction
1(P), 5(EA)/3(EB) port Side ported
Top ported
4(A)/2(B) port Top ported
SUP/EXH port type SUP/EXH individual port [5(EA), 3(EB) individual]
Applicable connector M12 waterproof connector
Internal wiring Positive common, Negative common
SY3000 1/8
Side ported 1(P), 5(EA)/3(EB) port, 4(A)/2(B) port SY5000 1/4
SY7000 3/8
SY3000 1/8
Bottom ported 1(P), 5(EA)/3(EB) port, 4(A)/2(B) port SY5000 1/4
Port size
SY7000 3/8
SY3000 1/8
1(P), 5(EA)/3(EB) port SY5000 1/4
Top ported
SY7000 3/8
4(A)/2(B) port Compliant with the valve∗1
Enclosure (Based on IEC60529) IP67
Side ported 99
SY3000 Bottom ported 109
Top ported 104
Side ported 145
Weight: W [g]∗2 SY5000 Bottom ported 172
Top ported 159
Side ported 205
SY7000 Bottom ported 232
Top ported 227
∗1 Refer to page 17 for valve specifications.
∗2 The valve and cable weights are not included. To obtain the weight with valves attached, add the valve weights given on page 1 9 , and to include the
cable weight, add the connector cable weight on page 307.

Plug-in Sub-plate Flow Rate Characteristics


Rubber Seal
Sub-plate Fitting port size 1 J 4/2 4/2 J 5/3
Series
piping location (P, E) (A, B) C b Q [l/min(ANR)]∗2 C b Q [l/min(ANR)]∗2
Side ported 1/8 1/8 1.8 0.27 449 1.7 0.26 422
SY3000 Bottom ported 1/8 1/8 1.7 0.23 414 1.4 0.27 349
Top ported 1/8 C6 1.3 0.34 339 1.5 0.27 374
Side ported 1/4 1/4 4.2 0.21 1012 4.0 0.26 992
SY5000 Bottom ported 1/4 1/4 4.0 0.19 953 4.0 0.23 975
Top ported 1/4 C8 2.9 0.29 733 4.1 0.33 1063
Side ported 3/8 3/8 6.5 0.24 1593 6.3 0.23 1535
SY7000 Bottom ported 3/8 3/8 6.4 0.22 1591 6.3 0.22 1526
Top ported 3/8 C12 5.4 0.30 1373 6.0 0.27 1497

Metal Seal
Sub-plate Fitting port size 1 J 4/2 4/2 J 5/3
Series
piping location (P, E) (A, B) C b Q [l/min(ANR)]∗2 C b Q [l/min(ANR)]∗2
Side ported 1/8 1/8 1.4 0.14 325 1.3 0.26 322
SY3000 Bottom ported 1/8 1/8 1.3 0.13 300 1.3 0.22 315
Top ported 1/8 C6 1.2 0.22 291 1.4 0.29 354
Side ported 1/4 1/4 3.2 0.13 738 3.5 0.16 820
SY5000 Bottom ported 1/4 1/4 3.0 0.12 688 3.2 0.17 754
Top ported 1/4 C8 2.6 0.23 634 3.2 0.19 762
Side ported 3/8 3/8 4.6 0.10 1044 4.9 0.16 1148
SY7000 Bottom ported 3/8 3/8 4.6 0.10 1044 4.9 0.17 1154
Top ported 3/8 C12 4.0 0.18 947 4.7 0.16 1101
∗ Calculation of effective area S and sonic conductance C: S = 5.0 x C
∗1 The value is for individually operated 2-position type.
∗2 The values have been calculated according to ISO 6358 and indicate the flow rate under standard conditions with an inlet pressure of 0.6 MPa (relative
pressure) and a pressure drop of 0.1 MPa.

305
Plug-in Single Unit/Sub-plate Type [IP67 Compliant]
(Side ported, Bottom ported, Top ported) SY3000/5000/7000 Series
How to Order
In the case of Valve + Sub-plate (Built-in valve type part no.)
Side/Bottom
ported SY 3 1 0 0 5 1 W1 01
Top ported SY 3 1 3 0 5 1 M5 W1 01
q w e r t y u i o !0 !1 !2 !3 !4 !5 !6 !7
q Series o Light/surge voltage suppressor and common specification !2 A, B port thread type (Thread piping)
3 SY3000 Surge voltage Common — Rc
Symbol With light
5 SY5000 suppressor specification F G
7 SY7000 — — — N NPT
R — Non-polar T NPTF
w Type of actuation U  ∗ Only — is available for M5.
1 Single S — Positive

2
2-position
Double Z  common !3 Type of mounting screw
3 Closed Centre NS — Negative — Round head combination screw
4 3-position Exhaust Centre NZ  common B Hexagon socket head cap screw
5 Pressure Centre ∗ For the non-polar type, be careful of surge K Round head combination screw (Drop prevention type)
A∗1 N.C./N.C. voltage intrusion. Refer to page 317 for details. H Hexagon socket head cap screw (Drop prevention type)
4-position ∗ Only “Z” and “NZ” types are available with a
B∗1 dual 3-port
N.O./N.O. ∗ For “K” and “H,” the valve body cover has a
power saving circuit.
C∗1 N.C./N.O. drop prevention construction to stop the
mounting screws from falling out when the
∗1 Only the rubber seal type is available for the
4-position dual 3-port valve.
!0 Manual override valve is removed for maintenance, etc.
—: D: ∗ Refer to page 307 when the base gaskets
e Seal type Non-locking
push type
Push-turn
locking
and mounting screws are required for
maintenance.
0 Rubber seal slotted ∗ When using an optional spacer assembly,
1 Metal seal type “B” and “H” cannot be selected.

r Pilot type !4 Wiring specifications (Sub-plate)


— Internal pilot WO Without M12 connector cable
R External pilot E: F: W1 With M12 connector cable (300 mm)
Push-turn Slide locking W2 With M12 connector cable (500 mm)
t Back pressure check valve (Built-in valve type) locking lever
type
type W3
W4
With M12 connector cable (1000 mm)
With M12 connector cable (2000 mm)
— None
W7 With M12 connector cable (5000 mm)
H Built-in
∗ When ordering a product with M12 connector
∗ Only the rubber seal type is available.
cable, the connector cable is included.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000. ∗ Refer to page 36 for the safety slide locking
manual override.
!5 Port location (Sub-plate)
— Side ported
y Pilot valve option !1 A, B port size (∗ Top-ported valve only) B Bottom ported
— Standard (0.7 MPa) V∗1 Top ported (1P, 5EA, 3EB port: Side ported)
Thread piping
B Quick response type (0.7 MPa) ∗1 Only available for the valve piping type “3”
K∗1 High pressure type (1.0 MPa) Symbol Port size Applicable series top ported
∗1 Only the metal seal type is available for the
M5 M5 x 0.8 SY3000
high pressure type. 01 1/8 SY5000 !6 Port size (Sub-plate)
02 1/4 SY7000 Symbol Port size Applicable series
u Coil type Metric size (One-touch fitting) 01 1/8 SY3000
— Standard Symbol A, B port SY3000 SY5000 SY7000 02 1/4 SY5000
T With power saving circuit (Continuous duty type) C2 Ø2  — — 03 3/8 SY7000
∗ Be sure to select the power saving circuit C3 Ø 3.2  — —
type if the valve is to be continuously C4 Ø4   — !7 Thread type (Sub-plate)
energized for long periods of time. C6 Ø6   
∗ Be careful of the energizing time when the
— Rc
C8 Ø8 —   F G
power saving circuit is selected. Refer to page
316 for details. C10 Ø 10 — —  N NPT
C12 Ø 12 — —  T NPTF
i Rated voltage Inch size (One-touch fitting)
5 24 VDC Symbol A, B port SY3000 SY5000 SY7000
6 12 VDC N1 Ø 1/8"  — —
N3 Ø 5/32"   —
N7 Ø 1/4"   
N9 Ø 5/16" —  
N11 Ø 3/8" — — 

∗ When mounting a special order (including Made-to-Order specification) valve or manifold option (spacer, etc.) on the sub-plate, add the valve part
number or spacer part number under the sub-plate part number to place an order. For details, refer to the ordering example on page 307.
∗ When selecting a product with residual pressure release valve or vacuum release valve with restrictor, after selecting a model from page 26 or 28, make
selections for items 15 to 18 above.
306
SY3000/5000/7000 Series

How to Order
In the case of Sub-plate (Sub-plate single unit part no.)
∗ Without valve
SY 3 0M 27 1 W1 01
q w e r t ∗ Base gasket is included.
∗ Valve mounting screws are not included.
q Series e Port location (Sub-plate) t Sub-plate thread type
3 SY3000 — Side ported — Rc
5 SY5000 B Bottom ported F G
7 SY7000 V Top ported [1(P), 5(EA), 3(EB) port: Side ported] N NPT
T NPTF
w Wiring specifications r Port size
WO Without M12 connector cable Symbol Port size Applicable series
W1 With M12 connector cable (300 mm) 01 1/8 SY3000
W2 With M12 connector cable (500 mm) 02 1/4 SY5000
W3 With M12 connector cable (1000 mm) 03 3/8 SY7000
W4 With M12 connector cable (2000 mm)
W7 With M12 connector cable (5000 mm)
∗ Refer to the table below for connector cable
How to Order when mounting a special order (including Made-to-Order specification)
part numbers. valve on the sub-plate (Ordering example: X90)
∗ When ordering a product with M12 connector
cable, the connector cable is included. SY30M-27-1-W1-01 ······ 1 set (Sub-plate single unit part no.)
∗SY3200-5U1-X90·········· 1 set (2-position double part no./Main valve fluororubber specification)

Ordering example when mounting a manifold option (spacer, etc.)

SY30M-27-1-W1-01 ······ 1 set (Sub-plate single unit part no.)


∗SY3400-5U1 ················· 1 set (3-position exhaust centre part no.)
∗SY30M-60-1A ··············· 1 set (Part no. for double check spacer with residual pressure release valve)

Caution
Due to the properties of the double check spacer, assembly carried out by the customer is not
recommended. If a double check spacer is to be used, be sure to order the type that is built in
to the sub-plate as shown in the ordering example above.

Sub-plate Parts Nos.

∗ 3 pcs.
q No. Description
Part no.
Note
SY3000 SY5000 SY7000
for the SY7000
Round head SY3000-23-24A SY5000-221-1A SY7000-221-1A Part numbers shown on
Valve combination screw (M2 x 32) (M3 x 32.5) (M3 x 36.5) the left are for 10 valves
q mounting
screw Hexagon socket SY3000-222-1A SY5000-222-1A SY7000-222-1A (20 pcs.).
head cap screw (M2 x 32) (M3 x 32.5) (M3 x 36.5) (30 pcs. for the SY7000)
Base gasket Part numbers shown on the
w (for sub-plate) SY30M-11-1A SY50M-11-1A SY70M-11-1A left are for 10 valves (10 pcs.).
Cable length: 300 mm
ZS-37-L
w Cable weight: Approx. 18 g
Cable length: 500 mm
ZS-37-M Cable weight: Approx. 23 g
M12 waterproof Cable length: 1000 mm
e connector cable ZS-37-N Cable weight: Approx. 36 g
Cable length: 2000 mm
e ZS-37-P Cable weight: Approx. 62 g
Cable length: 5000 mm
ZS-37-C Cable weight: Approx. 140 g

Caution
Tightening torque
M2: 0.16 N·m (SY3000)
M3: 0.8 N·m (SY5000/7000)

307
Plug-in Single Unit/Sub-plate Type [IP67 Compliant]
(Side ported, Bottom ported, Top ported) SY3000/5000/7000 Series
Plug-in Side Ported
Dimensions: SY3000 Series Single Unit/Sub-plate Top Ported
SY30 01 -1-W-01 (Side ported)
1/8
[1(P) port]

(For E type: 62.2)


(For F type: 64.3)
58.6
28
19.5
17.7

20
7.4
Triangle mark Sub-plate side pin arrangement
M5 x 0.8 M5 x 0.8 (No numeric indication)
(PE: External pilot EXH port) (X: External pilot port) COM.
1/8 11 11 9.5
[5(EA), 3(EB) port] 4
3
2
28.6 5.2
SOL.a 1 SOL.b
Manual override 83.2 Unused (Without terminal)

(Push-turn locking slotted type:


Press, then rotate it. ) 51.1
34.5 8.8 2 x Ø 3.2
4(A) port side: Blue (For rubber seal) (For mounting)
: Grey (For metal seal) 4A 2B
2(B) port side: Yellow
35.9
32.9
BA
14 A

12 B

PE X
(Light/surge voltage suppressor) 5EA 1P 3EB

(42.1)
10.6
52.2 5.8
11.9

67.9 (15.3)
(For 3-position)

14.5 13.3
For "F" marking 1/8
(Thread type) [4(A), 2(B) port] 1: Brown (Unused) 3: Blue (COM.)
12

19

2: White (SOL.b) 4: Black (SOL.a)


F

∗ These figures show the “SY3200-5Z1-WO-01F.”

SY33 01 -1--W-V01 (Top ported)


(M5 threaded type)
(72.8)
58.6
(Max. 3)

4A 2B
B A
4 A

2B

PE X
(Light/surge voltage suppressor) 5EA 1P 3EB

11 15 M5 x 0.8 (For threaded type)


One-touch fitting
[4(A), 2(B) port]
[4(A), 2(B) port]
Applicable tube O.D.: Ø 2
: Ø 3.2, Ø 1/8"
: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4" Plug

∗ These figures show the “SY3230-5Z1-C6-WO-V01F.”


∗ 1(P), 5(EA), 3(EB), X, and PE ports are side ported.
308
SY3000/5000/7000 Series
Plug-in
Dimensions: SY3000 Series Single Unit/Sub-plate Bottom Ported
SY30 01 -1-W-B01 (Bottom ported)

(For E type: 62.2)


(For F type: 64.3)
Sub-plate side pin arrangement

58.6
(No numeric indication)

28
19.5

20
COM.

3 Triangle mark Plug


4 2 M5 x 0.8
M5 x 0.8 28.6 5.2 (X: External pilot port)
SOL.a 1 SOL.b
(PE: External pilot EXH port) Plug
Unused (Without terminal)

Manual override 83.2

(Max. 3)
(Push-turn locking slotted type:
Press, then rotate it. ) 51.1
34.5 8.8 2 x Ø 3.2
4(A) port side: Blue (For rubber seal) (For mounting)
: Grey (For metal seal) 4A 2B
2(B) port side: Yellow

35.9
32.9
B A
(42.1)

14 A

12 B
10.6
PE X
(Light/surge voltage suppressor) 5EA 1P 3EB

(Max. 3)
52.2 5.8

11.9
67.9 (15.3)
(For 3-position)
1: Brown (Unused) 3: Blue (COM.)
2: White (SOL.b) For "F" marking
4: Black (SOL.a) Plug
(Thread type)

19
F

Panel fitting dimensions


32.5

14.7
3.7

8.2

13 13 7.5
5 3 1
3.5

28.3

29.5
4 2
34.5 2 x M3 1/8
2 x Ø 3.4 [1(P), 2(A), 4(B), 5(EA), 3(EB) port] Fitting dimensions for panel mounting
42.5
14.5 13.3 Refer to panel fitting dimensions
for details.

∗ These figures show the “SY3200-5Z1-WO-B01F.”

309
Plug-in Single Unit/Sub-plate Type [IP67 Compliant]
(Side ported, Bottom ported, Top ported) SY3000/5000/7000 Series
Plug-in Side Ported
Dimensions: SY5000 Series Single Unit/Sub-plate Top Ported
SY50 01 -1-W-02 (Side ported)
1/4
[1(P) port]

(For E type: 62.2)


(For F type: 64.3)
Sub-plate side pin arrangement
(No numeric indication)

58.6
COM.

28
15.5
13
3
4 2
Triangle mark SOL.a 1 SOL.b
18 18 16
1/4 Unused (Without terminal)
[5(EA), 3(EB) port]
Manual override ( 103.4
Push-turn locking slotted type:
Press, then rotate it. ) 2 x Ø 4.3
(For mounting)
71.3
62 7.4
4(A) port side: Blue (For rubber seal)
: Grey (For metal seal) PE 4A 2B X
2(B) port side: Yellow
32

40
B A
14 A

12 B

(Light/surge voltage suppressor) 5EA 1P 3EB


4

(42.1)
10.6
11.9

74.6 3.4

90.3 (16.6)
(For 3-position)

For "F" marking 1/4


46.4 10.8
(Thread type) [4(A), 2(B) port]
1: Brown (Unused) 3: Blue (COM.)
M5 x 0.8 18 25 M5 x 0.8
2: White (SOL.b) 4: Black (SOL.a)
(PE: External pilot EXH port) (X: External pilot port)
15.5

13

17.5

∗ These figures show the “SY5200-5Z1-WO-02F.”

SY53 01 -1--W-V02 (Top ported)


(For 01 threaded type)
(76.7)
(62.3)
(Max. 3)

For "F" marking


14.5 26.8
(Thread type)
<For 01> PE 4A 2B X
F
B A
4 A

2 B

5EA 1P 3EB

One-touch fitting (16.2) 25.9 1/8 (For threaded type)


[4(A), 2(B) port] (For threaded type) (For threaded type) [4(A), 2(B) port]
Applicable tube O.D.: Ø 4, Ø 5/32"
Ø 6, Ø 1/4"
Ø 8, Ø 5/16"
Plug

∗ These figures show the “SY5230-5Z1-C8-WO-V02F.”


∗ 1(P), 5(EA), 3(EB), X, and PE ports are side ported.
310
SY3000/5000/7000 Series
Plug-in
Dimensions: SY5000 Series Single Unit/Sub-plate Bottom Ported
SY50 01 -1-W-B02 (Bottom ported)

Fitting dimensions for panel mounting


Refer to panel fitting dimensions
for details.
18 18 16

Sub-plate side pin arrangement

30.5
9.5
(No numeric indication)
5 1 3
4 2

COM.
1/4 18 25
3 [1(P), 2(A), 4(B), 5(EA), 3(EB) port]
4 2

SOL.a 1 SOL.b

(For E type: 62.2)


(For F type: 64.3)
Unused (Without terminal)

58.6
28
15.5
Triangle mark Plug

103.4
(42.1)

10.6 Manual override

(Max. 3)
71.3
(Push-turn locking slotted type:
Press, then rotate it. ) 2 x Ø 4.3
(For mounting)
62 7.4
4(A) port side: Blue (For rubber seal)
: Grey (For metal seal) PE 4A 2B X

(Max. 3)
2(B) port side: Yellow

32

40
B A
14 A

12 B
1: Brown (Unused) 3: Blue (COM.) (Light/surge voltage suppressor) 5EA 1P 3EB

4
2: White (SOL.b) 4: Black (SOL.a)
74.6 3.4

11.9
90.3 (16.6)
Panel fitting dimensions (For 3-position)

2 x M4
2 x Ø 4.5 For "F" marking
(Thread type) 46.4 10.8
M5 x 0.8 M5 x 0.8
4.5

32
40

Plug
(PE: External pilot EXH port) (X: External pilot port)
15.5

17.5

3.5 57
4

F
62

∗ These figures show the “SY5200-5Z1-WO-B02F.”

311
Plug-in Single Unit/Sub-plate Type [IP67 Compliant]
(Side ported, Bottom ported, Top ported) SY3000/5000/7000 Series
Plug-in Side Ported
Dimensions: SY7000 Series Single Unit/Sub-plate Top Ported
SY70 01 -1-W-03 (Side ported)
3/8
[1(P) port]

(For E type: 67.9)


Sub-plate side pin arrangement

(For F type: 70)


(No numeric indication)

64.3
COM.

30.5
23
16
3
4 2

Triangle mark SOL.a 1 SOL.b


22.5 22.5 17.5
3/8 Unused (Without terminal)
[5(EA), 3(EB) port]
Manual override 116.7
84.6
(Push-turn locking slotted type:
Press, then rotate it. ) 2 x Ø 4.3
(For mounting) 73 8.1
4(A) port side: Blue (For rubber seal)
: Grey (For metal seal) PE 4A 2B X

2(B) port side: Yellow

38

46
B A
14 A

12 B

(42.1)
(Light/surge voltage suppressor)
5 EA 1P 3 EB 15.7

4
4.1
11.9
87.2
102.9 (20.6)
(For 3-position)

For “F” marking 3/8


54.8 12.6 1: Brown (Unused) 3: Blue (COM.)
(Thread type) [4(A), 2(B) port]
22.5 28.8 2: White (SOL.b) 4: Black (SOL.a)
M5 x 0.8 M5 x 0.8
(PE: External pilot EXH port) (X: External pilot port)
16
22
23

∗ These figures show the “SY7200-5Z1-WO-03F.”

SY73 01 -1--W-V03 (Top ported)


(For C12: 93.8)
(For 02 threaded type)
(84.5)
(73)
(Max.3)

PE 4A 2B X
B A
4A

2B

5 EA 1P 3 EB

One-touch fitting 22.6 30.2 1/4 (For threaded type)


[4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
: Ø 10, Ø 3/8" Plug
: Ø 12

∗ These figures show the “SY7230-5Z1-C10-WO-V03F.”


∗ 1(P), 5(EA), 3(EB), X, and PE ports are side ported.
312
SY3000/5000/7000 Series
Plug-in
Dimensions: SY7000 Series Single Unit/Sub-plate Bottom Ported
SY70 01 -1-W-B03 (Bottom ported)
Fitting dimensions for panel mounting
Refer to panel fitting dimensions
22.5 22.5 17.5
for details.

13

33
Sub-plate side pin arrangement 5 1 4

(No numeric indication) 2 3

COM. 3/8 22.5 28.8


[1(P), 2(A), 4(B), 5(EA), 3(EB) port]
3
4 2

SOL.a 1 SOL.b

Unused (Without terminal)

(For E type: 67.9)


(For F type: 70)
64.3
30.5
23
Triangle mark Plug
(42.1)

15.7 116.7
Manual override

(Max.3)
84.6
(Push-turn locking slotted type:
Press, then rotate it. ) 2 x Ø 4.3
(For mounting) 73 8.1
4(A) port side: Blue (For rubber seal)
: Grey (For metal seal) PE 4A 2B X

(Max.3)
2(B) port side: Yellow

38

46
B A
14 A

12 B
1: Brown (Unused) 3: Blue (COM.)
5 EA 1P 3 EB
2: White (SOL.b) 4: Black (SOL.a) (Light/surge voltage suppressor)

4
87.2 4.1

11.9
102.9 (20.6)
Panel fitting dimensions (For 3-position)
2 x M4
4.5

2 x Ø 4.5
For “F” marking
(Thread type)
54.8 12.6
46.2
38

M5 x 0.8 M5 x 0.8
(PE: External pilot EXH port) Plug (X: External pilot port)
22
23

69
F
73

∗ These figures show the “SY7200-5Z1-WO-B03F.”

313
SY3000/5000/7000 Series
Specific Product Precautions 1
Be sure to read this before handling the products. Refer to the back cover for safety instructions.
For 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products”
and the “Operation Manual” on the SMC website: https://www.smc.eu

Environment Manual Override

Warning Warning
1. Do not use valves in atmospheres of corrosive gases,  Push-turn locking lever type [E type]
chemicals, sea water, water, water vapour, or where there is Push down on the manual override by finger until it stops, and
direct contact with any of these. then turn it 60° clockwise. The manual override is then locked.
2. Products compliant with IP67 enclosures (based on IEC60529) To release it, turn it counterclockwise. If it is not turned, it can
are protected against dust and water, however, these products be operated the same way as the non-locking push type.
cannot be used in water. If using in an environment that is
exposed to water and dust splashes, take measures such as
Locked
using a protective cover.
position
3. When using built-in silencer type manifold with an IP67
enclosure, keep the exhaust port of the silencer from coming in
direct contact with water or other liquids.
4. The metal seal valve is provided with a hole to discharge the OFF
pilot EXH. When using in atmospheres containing water and
dust, mount it horizontally. ON
B

Valve Mounting
Carefully check the manual override
Caution projection amount.

(3.7)
Mount it so that there is no Max. (at OFF): 3.7 mm
Series Thread size Tightening torque
slippage or deformation in SY3000 M2 0.16 N·m
gaskets, and tighten with SY5000/7000 M3 0.8 N·m
the tightening torque as
shown to the right.

Manual Override Caution


Do not apply excessive torque when turning the manual
Warning override. [0.1 N·m]
When locking the manual override, be sure to push it down
Regardless of an electric signal for the valve, the manual override
before turning. Turning without first pushing it down can cause
is used for switching the main valve. Connected actuator is
damage to the manual override and other trouble such as air
started by manual operation. Use the manual override after
leakage, etc.
confirming that there is no danger.
 Slide locking type (Manual)
 Non-locking push type
It is locked by sliding the manual override all the way in the
Push down on the manual
direction indicated by the arrow (ON side) with a small flat
override button until it stops.
head screwdriver or with your fingers. Slide it in the direction
indicated by the arrow (OFF side) to release it.

OFF Locked
position
ON

 Push-turn locking slotted type [D type]


OFF
Push down on the manual override with a small flat head
screwdriver until it stops, and then turn it 90° clockwise. The B
manual override is then locked. To release it, turn it counter- ON
clockwise. A
If it is not turned, it can be operated the same way as the
non-locking push type.
Locked
position

PUSH
TURN

B A

314
SY3000/5000/7000 Series
Specific Product Precautions 2
Be sure to read this before handling the products. Refer to the back cover for safety instructions.
For 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products”
and the “Operation Manual” on the SMC website: https://www.smc.eu

Back Pressure Check Valve Valve and Manifold Combination


The SY series plug-in valve has the common configuration of the
Caution 3
valve mounting surface between base-mounted type (SY 57 0)
3
There are two types of back pressure check valves; the type and top-ported type (SY 7 3), therefore, it can be mounted to all
5

which is built into a valve (rubber seal type only) and the type manifolds of the side-ported type (Type 5 0 and Type 1 0 ), the
which is built in on the manifold side with a connector bottom-ported type (Type 51 and Type 11), and the top-ported type
connection. Both types have a check valve built in to prevent (Type 5 2 and Type 1 2 ). For example, air output can be obtained
back pressure. from both sides of the A and B ports of the manifold and the valve
Please note that for this reason, even if a valve with an external by mounting a top-ported valve to a side-ported or bottom-ported
pilot specification is used, it cannot be pressurised from exhaust manifold, and a pressure switch can be connected to the output
port [3/5(E)]. As compared with the types which do not integrate port on one side. However, when selecting valves and manifolds,
the back pressure check valve, C value of the flow rate note that when a base-mounted valve is mounted to a top-ported
characteristics goes down. Please contact SMC for details. manifold, there will be no output from the A and B port.
The manifold installed type back pressure check valve
assembly is assembly parts with a check valve structure.
However, since slight air leakage against the back pressure is
allowed due to its structure, adverse effects of the back
pressure due to increase in exhaust resistance cannot be
prevented if the manifold exhaust port and other exhaust ports
are put together for piping or if the piping diameter is narrowed.
As a result, this may cause the actuator and air operated
equipment to malfunction. So, be careful not to restrict the
exhaust air. If the exhaust resistance becomes large, select a
built-in valve type with rubber seal.
Do not switch valves when A or B port is open to the
atmosphere, or while the actuators and air operated equipment
are in operation. For built-in valve type with rubber seal, the
back pressure prevention seal may be peeled off, which may
cause air leakage or malfunctions. Use caution especially when
performing a trial operation or maintenance work.

Exhaust Throttle

Caution
The SY series pilot valve and main valve share a common
exhaust inside the valve. Therefore, do not block the exhaust port
when arranging the piping.

Used as a 3-Port Valve

Caution
 In case of using a 5-port valve as a 3-port valve
The SY3000/5000/7000 series can be used as normally closed
(N.C.) or normally open (N.O.) 3 -port port valves by closing
one of the cylinder ports 4 (A) or 2 (B) with a plug. However,
they should be used with the exhaust ports kept open. They
are convenient at times when a double solenoid type 3 -port
valve is required.

Plug position B port A port


Type of actuation N.C. N.O.
(A)4 2(B) (A)4 2(B)
Number of solenoids

Single
(EA)5 1 3(EB) (EA)5 1 3(EB)
(P) (P)

(A)4 2(B) (A)4 2(B)

Double
(EA)5 1 3(EB) (EA)5 1 3(EB)
(P) (P)

315
SY3000/5000/7000 Series
Specific Product Precautions 3
Be sure to read this before handling the products. Refer to the back cover for safety instructions.
For 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products”
and the “Operation Manual” on the SMC website: https://www.smc.eu

Light/Surge Voltage Suppressor

Caution
 Polar type  With power saving circuit
Positive common Negative common Power consumption is decreased to approx. 1/3 compared with
Single solenoid Single solenoid the standard product by reducing the wattage required to hold
the valve in an energised state. (Effective energising time is
Light/surge voltage suppressor (Z) Light/surge voltage suppressor (NZ) over 67 ms at 24 VDC.)
Polarity protection diode Polarity protection diode ∗ Be careful of the energising time, as quick response and high pressure
COM COM types will become operational when the energising time is over 40 ms.
(+) (−)
LED <Standard> <High pressure>
Coil

Coil
LED
(Red) Electric circuit diagram
[SOL.a] [SOL.a] (Red)
(−) (+) (With power saving circuit) Polarity protection diode
In the case of single solenoid
Surge voltage suppressor (S) Surge voltage suppressor (NS) (+) (+)

Timer circuit
Diode

Diode

PWM circuit
Coil

Coil
Polarity protection diode Polarity protection diode
LED
COM COM
(+) (−)
i2 i1
Coil
Coil

(−)
[SOL.a] [SOL.a] (−)
(−) (+) i1: Inrush current, i2: Holding current
Polarity protection diode
Positive common Negative common Not available for the 12 VDC
specification
Double solenoid, Double solenoid,
3-position, 4-position 3-position, 4-position The circuit shown above reduces the power consumption for
Light/surge voltage suppressor (Z) Light/surge voltage suppressor (NZ) holding in order to save energy. Refer to the electrical power
[SOL.b] [SOL.b] waveform as shown below.
(−) (+) LED
LED <Electrical power waveform with power saving circuit>
Coil

Coil

(Green) (Green)
COM COM
Applied voltage
(+) (−)
LED 24 V
Coil

Coil

LED (Red)
[SOL.a] (Red) [SOL.a]
(−) (+) 0V
Polarity protection diode Polarity protection diode

Surge voltage suppressor (S) Surge voltage suppressor (NS)


[SOL.b] [SOL.b]
(−) (+) 0.4 (0.95) W
Coil

Coil

With power saving


COM COM circuit
0.1 (0.4) W
(+) (−)
Coil

Coil

[SOL.a] [SOL.a] 0W
(−) (+) 67 ms (40 ms)
Polarity protection diode Polarity protection diode
The values in ( ) are for the high pressure and quick response types.
 Non-polar type • The 12 VDC specification with power saving circuit (standard
With surge voltage suppressor (R) specification) does not have the polarity protection diode. Do
Single solenoid Double solenoid not make a mistake with the polarity.
SOL.b • Since the voltage will drop by approx. 0.5 V due to the
(−,+) transistor, pay attention to the allowable voltage fluctuation.
COM
Coil

(+,−) Varistor (For details, refer to the solenoid specifications of each type
COM of valve.)
Coil

Varistor
(+,−)
SOL.a
Coil

(−,+) Varistor
SOL.a
Residual voltage of the surge voltage suppressor
(−,+) ∗ If a varistor or diode surge voltage suppressor is used, there is
some residual voltage to the protection element and rated
With light/surge voltage suppressor (U)
voltage. Therefore, refer to the table below and pay attention to
Single solenoid Double solenoid the surge voltage protection on the controller side. Also, since
SOL.b LED the response time does change, refer to the valve
(−,+) specifications on page 18.
COM
Coil

(+,−) Varistor
COM Residual Voltage
Coil

Varistor (+,−)
SOL.a Surge voltage DC
Coil

(−,+) Varistor
LED suppressor 24 V 12 V
(Red) SOL.a
(−,+) LED S, Z Approx. 1 V
(Green) R, U Approx. 47 V Approx. 32 V
316
SY3000/5000/7000 Series
Specific Product Precautions 4
Be sure to read this before handling the products. Refer to the back cover for safety instructions.
For 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products”
and the “Operation Manual” on the SMC website: https://www.smc.eu

Continuous Duty Countermeasure for Surge Voltage Intrusion


 Surge voltage intrusion
Caution With non-polar type valves, at times of sudden interruption of
If a valve is energised continuously for long periods of time, the the loading power supply, such as emergency shutdown,
rise in temperature due to heat-up of the coil assembly may surge voltage intrusion may be generated from loading
cause a decline in solenoid valve performance, reduce service equipment with a large capacity (power consumption), and a
life, or have adverse effects on peripheral equipment. If the valve valve in a de-energised state may switch over (see Figure 1).
is energised continuously for long periods of time, be sure to use When installing a breaker circuit for the loading power supply,
a valve with power saving circuit. In particular, if three or more consider using a valve with polarity (with polarity protection
adjacent stations on the manifold are energised simultaneously diode), or install a surge absorption diode between the loading
for extended periods of time or if the valves on A side and B side equipment COM line and the output equipment COM line (see
are energised simultaneously for long periods of time, take Figure 2).
special care as the temperature rise will be greater.

UL Approved Product Output circuit

Caution Surge voltage


24 V
When conformity to UL is required, the product should be used sol.1: Energized
0V
with a UL1310 Class 2 power supply.
R −60 V
Surge voltage
Internal circuit

The product is a UL approved product only if it has a 24 V


mark on the body. 0V
sol.2: De-energized
R −60 V
Surge voltage
24 V
0V
Large capacity
R load: Energized −60 V

Relay
Power supply circuit breaker

24 VDC

Figure 1. Surge intrusion circuit example


(NPN outlet example) (24 VDC)

Output circuit

Surge voltage
24 V
sol.1: Energized
0V
−2 V
R
Surge voltage
Internal circuit

24 V
0V
sol.2: De-energized
−2 V
R
Surge voltage
24 V
0V
Large capacity −2 V
R load: Energized

Countermeasure
Diode parts

– (Anode) + (Cathode)

Relay
Power supply circuit breaker

24 VDC

Figure 2. Surge intrusion countermeasure example


(NPN outlet example) (24 VDC)
317
SY3000/5000/7000 Series
Specific Product Precautions 5
Be sure to read this before handling the products. Refer to the back cover for safety instructions.
For 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products”
and the “Operation Manual” on the SMC website: https://www.smc.eu

Light Indication Manifold Indication Symbol


When equipped with indicator light and surge voltage suppressor,
the light window turns red when solenoid a is energised, and it turns Caution
green when solenoid b is energised.
The letter “Í” is indicated on manifold blocks for the SY series
Light Type 1  (connector connecting base) as shown below. This
A side: Red indication refers to the type of substrate assembly (single wiring)
B side: Green inside the manifold blocks. When there is no symbol, double
wiring is used.
When the manifold specification sheet does not include a wiring
specification, all stations will be double wiring specification. In this
case, single and double solenoid valves can be mounted in any
position, but when a single valve is used, there will be an unused
Solenoid a control signal. To avoid this, indicate positions of manifold blocks
for single wiring specification and double wiring specification on a
manifold specification sheet. (Note that double, 3 -, or 4 -position
Solenoid b valves cannot be used for manifolds blocks with single wiring
specification Í.)

Type 5 (Metal Base) ,Type 1 (Connector Connecting Base) Changing Connector Entry Direction

Caution
Connector direction for electrical entry of D-sub connector
<IP 4 0 > and flat ribbon cable can be changed. If the directional
change is required, slide the lever on the side of the connector Single wiring
block to the FREE position, and then change the direction as marked with Í
shown in the figure. Also, before connecting the connector, be
sure to return the lever to the LOCK position. (If the lever is
difficult to slide, move the connector a little bit to make it easier to
slide the lever.)
If an excessive force is applied on the connector in the LOCK
position, the connector block may be damaged. Also, using in
such a way that the connector floats in the FREE position, it may
cause the lead wire, etc., to break. Thus, refrain from using in
these ways.

E
FRE
K
LOC

Type 5 Type 1
(Metal base) (Connector connecting base)

318
SY3000/5000/7000 Series
Specific Product Precautions 6
Be sure to read this before handling the products. Refer to the back cover for safety instructions.
For 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products”
and the “Operation Manual” on the SMC website: https://www.smc.eu

Substrate Assemblies inside Manifolds Port Block Assembly and How to Change Piping Types between Top and Side

Caution Caution
Substrate assemblies inside of manifolds cannot be taken apart. For the top-ported type, the port size of A and B ports can be changed
Attempting to do so may damage parts. by switching the port block assemblies which are mounted on the body.
The piping method can also be changed by switching the top-ported
type port block assembly with the side-ported type cover assembly.
Also, it may cause air leakage if the mounting screws are not tightened
Fixation of DIN Rail Mounting Type Manifolds securely enough when they are switched. Take care to tighten to the
correct tightening torque.
Caution Refer to pages 24 and 25 for part numbers of port block assembly and
1. When the manifold is fixed with bolts on a mounting surface, body cover assembly for A, B port and page 225 for part numbers of
etc., it can be operated just by fixing on both ends of the DIN port block assembly and body cover assembly for P, E port.
rail if the bottom surface of the DIN rail is entirely in contact When switching them while valves are mounted on a manifold, remove
with the mounting surface when mounted horizontally. the clip with a flat head screwdriver before switching the port plugs and
However, if it is used with other mounting or with side or the One-touch fittings. It may cause air leakage if the mounting screws
reverse mounting, fix the DIN rail with bolts at regular intervals. are not tightened or the clip is not inserted securely enough when they
As a guide, insert bolts in 2 locations for 2-5 stations, 3 are switched. Take care to tighten to the correct tightening torque.
locations for 6-10 stations, 4 locations for 11-15 stations, 5
locations for 16-20 stations, and 6 locations for 21-24 stations. Caution
2. When using the manifold with DIN rail in an environment where Tightening torque Mounting screw

any vibration or impact is applied to it, the DIN rail itself may be M2: 0.16 N·m (SY3000)
broken. In particular, if the installation surface vibrates when M3: 0.8 N·m (SY5000/7000)
mounting the manifold on the wall or if a load is directly applied Port block assembly
to the manifold, the DIN rail may be broken, causing the Thread piping
Refer to page 24.
manifold to drop. When any vibration, impact, or load is applied
to the manifold, be sure to use the direct mounting manifold. Mounting screw

Port block assembly


One-touch fitting
Refer to page 24.

Body cover assembly ∗ Part number is not shown on


Refer to page 25. the body cover assembly.

 How to change while mounted on a manifold


Port block assembly
Refer to page 225.

Exchange the One-touch


fittings with the port plugs.
Clip
Tension bolt a
Refer to page 224.

Plate

Cover assembly
Refer to page 225.

Plug assembly
For SY3000
Removable by screwing an
M3 screw into the centre hole
Plug assembly
Plate Refer to page 226.
319
SY3000/5000/7000 Series
Specific Product Precautions 7
Be sure to read this before handling the products. Refer to the back cover for safety instructions.
For 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products”
and the “Operation Manual” on the SMC website: https://www.smc.eu

How to Replace One-touch Fittings How to Replace One-touch Fittings

Caution Caution
By replacing One-touch fittings of valve or manifold base, it is Bottom ported (Type 11) Plate part nos. (10 pcs. included)
possible to change the connection diameter of the 4(A), 2(B), Secure enough space between A, B port
Series Part no.
1(P), 3/5(E) ports. the manifold blocks when the size
When replacing the One-touch fittings, remove the clip or the plate is detached and attached. SY5000 — SY50M-10-4A
plate and the plate mounting screws with a screwdriver before SY7000 — SY70M-10-4A
pulling the One-touch fittings off. Mount the One-touch fittings by Plate Ø 2, Ø 3, Ø 4
SY3000/5000
following the removal procedure in reverse. Mixed mounting type Ø 6, Ø 1/8" SY50M-10-5A
It may cause air leakage if the mounting screws are not tightened (For mounting Ø 5/32", Ø 1/4"
or the clip and the clip plate are not inserted securely enough the SY3000)∗1 Ø 8, Ø 5/16" SY50M-10-4A
when they are switched. Take care to tighten to the correct ∗1 The part number for mounting the
tightening torque. Refer to page 226 for part numbers of SY5000 is SY50M-10-4A.
One-touch fittings for valve or manifold. ∗ The part number for the SY5000/7000
Manifold block mixed mounting type is SY70M-10-4A.
 Valve

One-touch fitting
Other Tube Brands

Caution
1. When using other than SMC brand tube, confirm
Port plate that the following specifications are satisfied with
Caution respect to the tube outside diameter tolerance.
Tightening torque 1) Nylon tube within ±0.1 mm
2) Soft nylon tube within ±0.1 mm
M2: 0.16 N·m
(SY3000) 3) Polyurethane tube within +0.15 mm
M3: 0.8 N·m –0.2 mm
(SY5000/7000) Do not use tube which do not meet these outside diameter
 Plug-in metal base tolerances. It may not be possible to connect them, or they
may cause other trouble, such as air leakage or the tube
Side ported (Type 50) Bottom ported (Type 51) pulling out after connection.
Clip

One-touch One-touch Fittings


fitting

 Tube attachment/detachment for One-touch fittings


Plate
1) Tube attachment
1. Take a tube having no flaws on its periphery and cut it off
Plate mounting
at a right angle. When cutting the tube, use tube cutters
screw
TK-1, 2, or 3. Do not use pliers, nippers, scissors, etc. If
Plate assembly part nos. cutting is done with tools other than tube cutters, the tube
Clip part nos. (10 pcs. included) (10 pcs. included) may be cut diagonally or become flattened, etc., making
Series Part no. Series Part no. a secure installation impossible, and causing problems
SY3000 SY30M-19-2A SY3000 SY30M-10-3A such as the tube pulling out after installation or air
SY5000 SY50M-19-2A SY5000 SY50M-10-6A leakage. Allow some extra length in the tube.
SY7000 SY70M-19-2A SY7000 SY70M-10-7A 2. Grasp the tube and push it in slowly, inserting it securely
∗ Including mounting screw all the way into the fitting.
3. After inserting the tube, pull on it lightly to confirm that it
 Plug-in connector Clip part nos. (10 pcs. included) will not come out. If it is not installed securely all the way
connecting base A, B port into the fitting, this can cause problems such as air
Series Part no.
Side ported (Type 10) size leakage or the tube pulling out.
Port plate SY3000 — SY30M-19-1A
SUP/EXH block 2) Tube detachment
SY5000 — SY50M-19-6A
Clip SY7000 — SV3000-70-1A 1. Push in the release button sufficiently, pushing its collar
One-touch
equally around the circumference.
fitting SY3000/5000 Ø 2, Ø 3, Ø 4
Mixed mounting type Ø 6, Ø 1/8" SY50M-19-1A 2. Pull out the tube while holding down the release button
(For mounting Ø 5/32", Ø 1/4" so that it does not come out. If the release button is not
the SY3000)∗1 Ø 8, Ø 5/16" SY50M-19-6A pressed down sufficiently, there will be increased bite on
∗1 The part number for mounting the the tube and it will become more difficult to pull it out.
SY5000 is SY50M-19-6A. 3. When the removed tube is to be used again, cut off the
∗ The part number for the SY5000/7000 portion which has been chewed before reusing it. If the
mixed mounting type is SV3000-70-1A. chewed portion of the tube is used as is, this can cause
∗ If the port plate for the SUP/EXH block trouble such as air leakage or difficulty in removing the
Manifold block is required, please contact SMC. tube.
320
SY3000/5000/7000 Series
Specific Product Precautions 8
Be sure to read this before handling the products. Refer to the back cover for safety instructions.
For 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products”
and the “Operation Manual” on the SMC website: https://www.smc.eu

One-touch Fittings

Caution
When fittings are used, they may interfere with one another depending on their types and sizes. Therefore, the dimensions of the fittings
to be used should first be confirmed in their respective catalogues.
Fittings whose compliance with the SY series is already confirmed are stated below. If the fitting within the applicable range is selected,
there will not be any interference.

Applicable Fittings: KQ2H, KQ2S Series


Port Applicable tubing O.D.
Series Model Piping port Fittings
size Ø2 Ø 3.2 Ø4 Ø6 Ø8 Ø 10 Ø 12
KQ2H
SY330--M5 4A, 2B M5
KQ2S
KQ2H
1P, 5EA, 3EB 1/8
KQ2S
KQ2H
SY3000 X, PE M5
SS5Y3-50/51/52 (R) KQ2S
Manifold base KQ2H
1/8
KQ2S
4A, 2B
KQ2H
M5
KQ2S

Port Applicable tubing O.D.


Series Model Piping port Fittings
size Ø2 Ø 3.2 Ø4 Ø6 Ø8 Ø 10 Ø 12
KQ2H
SY530--01 4A, 2B 1/8
KQ2S
KQ2H
1P, 5EA, 3EB 1/4
KQ2S
KQ2H
SY5000 X, PE M5
SS5Y5-50/51/52 (R) KQ2S
Manifold base KQ2H
1/4
KQ2S
4A, 2B
KQ2H
1/8
KQ2S

Port Applicable tubing O.D.


Series Model Piping port Fittings
size Ø2 Ø 3.2 Ø4 Ø6 Ø8 Ø 10 Ø 12
KQ2H
SY730--02 4A, 2B 1/4
KQ2S
KQ2H
1P, 5EA, 3EB 3/8
KQ2S
SY7000
SS5Y7-50/51/52 (R) KQ2H
X, PE M5
Manifold base KQ2S
KQ2H
4A, 2B 1/4
KQ2S
 Trademark
DeviceNet™ is a trademark of ODVA.
EtherNet/IP™ is a trademark of ODVA.
CompoNet™ is a trademark of ODVA.
EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.

321
These safety instructions are intended to prevent hazardous situations and/or equipment
Safety Instructions damage. These instructions indicate the level of potential hazard with the labels of
“Caution,” “Warning” or “Danger.” They are all important notes for safety and must be
followed in addition to International Standards (ISO/IEC) 1), and other safety regulations.
1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Caution indicates a hazard with a low level of risk
ISO 4413: Hydraulic fluid power – General rules relating to systems.
Caution: which, if not avoided, could result in minor or moderate IEC 60204-1: Safety of machinery – Electrical equipment of machines.
injury. (Part 1: General requirements)
Warning indicates a hazard with a medium level of risk ISO 10218-1: Manipulating industrial robots - Safety.
etc.
Warning: which, if not avoided, could result in death or serious
injury.
Danger indicates a hazard with a high level of risk
Danger: which, if not avoided, will result in death or serious
injury.

Warning Limited warranty and


1. The compatibility of the product is the responsibility of the person Disclaimer/Compliance
who designs the equipment or decides its specifications.
Since the product specified here is used under various operating
Requirements
conditions, its compatibility with specific equipment must be decided by The product used is subject to the following “Limited warranty
the person who designs the equipment or decides its specifications based and Disclaimer” and “Compliance Requirements”.Read and
on necessary analysis and test results. The expected performance and accept them before using the product.
safety assurance of the equipment will be the responsibility of the person
who has determined its compatibility with the product. This person should Limited warranty and Disclaimer
also continuously review all specifications of the product referring to its 1. The warranty period of the product is 1 year in service or 1.5
latest catalogue information, with a view to giving due consideration to any years after the product is delivered, whichever is first. 2) Also,
possibility of equipment failure when configuring the equipment. the product may have specified durability, running distance
or replacement parts. Please consult your nearest sales
2. Only personnel with appropriate training should operate machinery
branch.
and equipment.
2. For any failure or damage reported within the warranty
The product specified here may become unsafe if handled incorrectly.
period which is clearly our responsibility, a replacement
The assembly, operation and maintenance of machines or equipment
product or necessary parts will be provided. This limited
including our products must be performed by an operator who is
warranty applies only to our product independently, and not
appropriately trained and experienced.
to any other damage incurred due to the failure of the
3. Do not service or attempt to remove product and machinery/ product.
equipment until safety is confirmed. 3. Prior to using SMC products, please read and understand
1. The inspection and maintenance of machinery/equipment should only the warranty terms and disclaimers noted in the specified
be performed after measures to prevent falling or runaway of the driven catalogue for the particular products.
objects have been confirmed. 2) Vacuum pads are excluded from this 1 year warranty.
2. When the product is to be removed, confirm that the safety measures as A vacuum pad is a consumable part, so it is warranted for a year after
mentioned above are implemented and the power from any appropriate it is delivered. Also, even within the warranty period, the wear of a
source is cut, and read and understand the specific product product due to the use of the vacuum pad or failure due to the
precautions of all relevant products carefully. deterioration of rubber material are not covered by the limited
3. Before machinery/equipment is restarted, take measures to prevent warranty.
unexpected operation and malfunction.
Compliance Requirements
4. Contact SMC beforehand and take special consideration of safety 1. The use of SMC products with production equipment for the
measures if the product is to be used in any of the following manufacture of weapons of mass destruction (WMD) or any
conditions. other weapon is strictly prohibited.
1. Conditions and environments outside of the given specifications, or use 2. The exports of SMC products or technology from one country
outdoors or in a place exposed to direct sunlight. to another are governed by the relevant security laws and
2. Installation on equipment in conjunction with atomic energy, railways, regulations of the countries involved in the transaction. Prior
air navigation, space, shipping, vehicles, military, medical treatment, to the shipment of a SMC product to another country, assure
combustion and recreation, or equipment in contact with food and that all local rules governing that export are known and
beverages, emergency stop circuits, clutch and brake circuits in press followed.
applications, safety equipment or other applications unsuitable for the
standard specifications described in the product catalogue.
3. An application which could have negative effects on people, property, Caution
or animals requiring special safety analysis.
SMC products are not intended for use as instruments
4. Use in an interlock circuit, which requires the provision of double
for legal metrology.
interlock for possible failure by using a mechanical protective function,
Measurement instruments that SMC manufactures or sells
and periodical checks to confirm proper operation.
have not been qualified by type approval tests relevant to the
metrology (measurement) laws of each country.
Caution Therefore, SMC products cannot be used for business or
certification ordained by the metrology (measurement) laws
1. The product is provided for use in manufacturing industries. of each country.
The product herein described is basically provided for peaceful use in
manufacturing industries.
If considering using the product in other industries, consult SMC
beforehand and exchange specifications or a contract if necessary.
If anything is unclear, contact your nearest sales branch.

Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.
SMC Corporation (Europe)
Austria +43 (0)2262622800 www.smc.at office@smc.at Lithuania +370 5 2308118 www.smclt.lt info@smclt.lt
Belgium +32 (0)33551464 www.smc.be info@smc.be Netherlands +31 (0)205318888 www.smc.nl info@smc.nl
Bulgaria +359 (0)2807670 www.smc.bg office@smc.bg Norway +47 67129020 www.smc-norge.no post@smc-norge.no
Croatia +385 (0)13707288 www.smc.hr office@smc.hr Poland +48 222119600 www.smc.pl office@smc.pl
Czech Republic +420 541424611 www.smc.cz office@smc.cz Portugal +351 214724500 www.smc.eu apoioclientept@smc.smces.es
Denmark +45 70252900 www.smcdk.com smc@smcdk.com Romania +40 213205111 www.smcromania.ro smcromania@smcromania.ro
Estonia +372 6510370 www.smcpneumatics.ee smc@info@smcee.ee Russia +7 8127185445 www.smc-pneumatik.ru info@smc-pneumatik.ru
Finland +358 207513513 www.smc.fi smcfi@smc.fi Slovakia +421 (0)413213212 www.smc.sk office@smc.sk
France +33 (0)164761000 www.smc-france.fr info@smc-france.fr Slovenia +386 (0)73885412 www.smc.si office@smc.si
Germany +49 (0)61034020 www.smc.de info@smc.de Spain +34 945184100 www.smc.eu post@smc.smces.es
Greece +30 210 2717265 www.smchellas.gr sales@smchellas.gr Sweden +46 (0)86031240 www.smc.nu smc@smc.nu
Hungary +36 23513000 www.smc.hu office@smc.hu Switzerland +41 (0)523963131 www.smc.ch info@smc.ch
Ireland +353 (0)14039000 www.smcautomation.ie sales@smcautomation.ie Turkey +90 212 489 0 440 www.smcpnomatik.com.tr info@smcpnomatik.com.tr
Italy +39 03990691 www.smcitalia.it mailbox@smcitalia.it UK +44 (0)845 121 5122 www.smc.uk sales@smc.uk
Latvia +371 67817700 www.smc.lv info@smc.lv

South Africa +27 10 900 1233 www.smcza.co.za zasales@smcza.co.za

Printing ZS 00 Printed in Spain Specifications are subject to change without prior notice and any obligation on the part of the manufacturer