Professional Documents
Culture Documents
Plug-in Type
Due to the flow increase,
the valve size can be reduced!
Saves energy and space
SY3000 SY5000 SY7000
10 mm 15 mm
18 mm
Ø 2, Ø 3.2,
Ø 4, Ø 6, and Ø 8∗1
fittings are connectable.
∗1 Type M10/M11 manifold
Metal Base ∗2 Values based on comparison with the existing SMC model
For details, refer to page 15.
Connector
Connecting Base
Sub-plate
SY3000/5000/7000 Series
CAT.EUS11-103E-UK
5-Port Solenoid Valve
Plug-in Connector Connecting Base [IP67∗1]
∗1 Refer to page 39 for details on IP67.
Manifold Plug-in
Side ported Bottom ported Top ported Compatible sub-plate type
<Enlarged view
of the connector>
Connector type manifold with 32 outputs
Wiring
D-sub Connector Flat Ribbon Cable Terminal Block Box Lead Wire
Circular Connector Serial Transmission
Serial Transmission Variations
Gateway-type Integrated-type (for input/output) Integrated-type (for output)
Series EX510 EX500 EX600 EX245 EX250 EX260 EX126 EX120 EX180
Applicable protocol
DeviceNetTM
PROFIBUS DP
CC-Link
EtherNet/IPTM
EtherCAT
PROFINET
CANopen
AS-Interface
OMRON CompoBus/S
CompoNetTM
Ethernet POWERLINK
IO-Link
EtherNet/IP™ compatible wireless base
PROFINET compatible wireless base
PROFIsafe
1
SY3000/5000/7000 Series
Power Saving
[Electrical power waveform Power consumption is reduced
Power Consumption with power saving circuit]
Applied voltage by the power saving circuit. Long Service Life
24 V
Power consumption is decreased to approx. 1/3 by
0.1 w
With
0V reducing the wattage required to hold the valve in an Metal seal
power saving energised state. (Effective energizing time is over 67 ms at (Service life:
circuit
200 million cycles)∗
24 VDC.) Refer to the electrical power waveform to the 1
0.4 (0.95) W With power
left.
0.35 w
saving circuit
0.1 (0.4) W ∗ Only products with an indicator light are ∗1 According to SMC life
Standard equipped with the power saving circuit. test conditions
0W ∗2 Please contact SMC if life
67 ms (40 ms) ∗ The value in ( ) is for the quick response
and high pressure types. test data is required.
A side
spool valve B side
A bottom-ported type is available (A and B ports). spool valve
Space saving
By using the bottom-ported type,
it is possible to reduce the amount • 3-port valves on the A and B sides can be operated independently.
of space required for installation. • When used as a 3-port valve, only half the number of stations
is required.
• Can also be used as a 4-position, 5-port valve
• A 4-position dual 3-port valve with a back pressure check valve
is also available.
• Combination examples
Series A side B side
Installation SYA 03 0 N.C. valve N.C. valve
Panel fitting SYB 03 0 N.O. valve N.O. valve
SYC 03 0 N.C. valve N.O. valve
BA BA BA B A B A B A B A B A B A B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A 14 A
Installation
space
12 B 12 B 12 B 12 B 12 B 12 B 12 B 12 B
12 B 12 B 12 B 12 B 12 B 12 B
2 sets 1 set
Number of
serial units
2
5-Port Solenoid Valve
Improved Functionality
Back Pressure Check Valve
This prevents actuator and air operated valve malfunctions caused by the exhaust from other valves.∗1
Built-in valve type Back pressure check valve Retrofit or pre-installed type
(Check seal) If the product is affected by back pressure after
(A) (B) installation, a back pressure check
4 2 valve assembly can be added.
5 1 3
5 4 1 2 3 (EA) (P) (EB)
(EA)(A) (P) (B) (EB)
FREE
LOCK
Lever Type SUP Stop Valve Spacer (With residual
ual pressure release valve)
A lever has been added to
manual override button!
Solenoid valves can be
replaced individually Easy to visually check
without shutting off the
main pressure!∗1
2-action operation
Push
STEP No tools are STEP
required. Locked
Turn
Air for solenoid valves can be shut off individually! Solenoid valves can be replaced individually!
The operation of an n The
T solenoid valves canan
actuator can be be
b replaced individually
ly
checked by individually
ually without
w stopping the
shutting off the air for
or equipment
e during
the solenoid valves on maintenance.
m
the base while the <Application example>
main air is being For air operated valves,
supplied during a trial
rial such as sanitary valves,
operation. and automatic valve
control
∗1 This product is only for internal pilot specifications as the external pilot air cannot be shut off.
3
SY3000/5000/7000 Series
Improved Functionality
Slotted Type
2-position single valve
SUP Stop Valve Spacer 4(A)
(With residual pressure release valve) 2(B)
5(EA)
1(P)
3(EB)
Button for manual release
of residual pressure 2-position single valve example
To exhaust residual pressure
on the cylinder side
Slotted Type
[Intermediate stop] [Drop prevention]
Double Check Spacer Double check spacer assembly Double check spacer assembly
(With residual pressure release valve)
Long intermediate stops and position holding are possible.
4
5-Port Solenoid Valve
Improved Safety
Made to Order SY7000-X13
With safety slide locking manual override
SY3000/5000/7000-X13 SY5000-X13
Double-action operation
Before operation The slide locking manual overrides Operation 1 The safety slide cover is operated Operation 2 The slide locking manual
cannot be turned ON with the safety slide and moves upward. (Unlocked) overrides can be operated.
cover in place. (OFF status: Locked)
Safety slide cover Slide locking manual overrides
<OFF>
<ON>
Visual check
Red lines visible from three directions can be Safety slide covers can be checked from their raised and
checked to confirm whether the safety slide lowered positions.
cover is unlocked (FREE).
Safety slide cover
Valve state
Unlocked (raised/lowered)
Red lines
Locked
Made to Order
2-Position Single Solenoid Valve with Built-in Return Spring (Only rubber seal type)
SY3000/5000/7000-X350
The main valve returns to the OFF position when it is not
pressurized.
5
6
5-Port Solenoid Valve
Thread piping
Body cover assembly
Cover assembly
Refer to page 24 for part numbers of the port block assembly for the
A and B ports, page 225 for part numbers of the port block assembly
for the P and E ports, and page 319 for how to change piping types.
Side ported
7
SY3000/5000/7000 Series
Made to order
Application Examples
For the control of separately mounted valves For the control of vacuum ejectors by
Blanking plate means of Fieldbus unit signals
with output
(With M12 connector) Blanking plate with output
(With connector)
Vacuum unit
ZK2 Series
Separately
mounted valve
Mountable manifolds
Side ported/Type 50
Metal base
Bottom ported/Type 51
Connector Side ported/Type 10
connecting base Bottom ported/Type 11
Application Examples
For the detection of output pressure For the identification of faulty parts
Operation can be checked by monitoring the pressure A faulty part can quickly be identified by monitoring the operation of solenoid valves.
required to open or close air operated valves.
Solenoid valve Actuator
Air slide table
Rodless cylinder
Air gripper
8
5-Port Solenoid Valve
Only for External Pilot Vacuum Release Valve with Restrictor SY 35 AR Series
Vacuum suction and release can be controlled with a single valve!
Restrictor
PE • Flow rate adjustment of release air
Pilot EXH port • Prevents workpiece blow-off
<Manual operation>
2(B)
Vacuum pad port
X
External pilot port 1(P)
Release pressure port
3/5(E)
Vacuum pressure port
SOL.b
SOL.b
SOL.b
SOL.b
SOL.a
SOL.a
SOL.a
SOL.a
SOL.a
Mountable manifolds
Side ported Bottom ported Top ported
9
SY3000/5000/7000 Series
Application Examples
For tool changing For spot welding For rotary tables
Welding environment Wired system
Communication line Power supply line
Power supply
line only
Circular connector
Negative common
Positive common
Flat ribbon cable
D-sub connector
C2
Straight piping
EX510
EX600
EX245
EX250
EX260
EX126
EX120
EX180
5 ports
Top ported Bottom ported Side ported
Connector Connecting Base
Type
SY30
10 SY50 —— ————
From
p. 43 —
SY70
Type
SY50
Manifold
11 —— —————
From
p. 43
SY70
SY33 —
Type —
12 SY53 —— —
Plug-in
From
p. 55 — —
SY73 —
Top ported Bottom ported Side ported
SY30 —
Type
50 SY50 ————— ————————— —
From
p. 247 — —
Metal Base
SY70 —
SY30 —
Type
51 SY50 ————— ————————— —
From
p. 247 — —
SY70 —
Plug-in
SY33 —
Type
—
52 SY53 ————— ————————— —
From
p. 267 — —
SY73 —
SY303 —
Sub-plate
—
From
SY503 — — — — — —
Plug-in
p. 306 —————————— —— —
M12 connector SY703 ——
Standard Option Made to order (Refer to page 36.)
11
SY3000/5000/7000 Series
Valves with
Port Size Manifold Options pp. 203-218 pp. 268-278 Valve Options Function
Enclosure IP67
Blanking plate
C3 C4 C6 C8 C10 C12
Name plate
(N1) (N3) (N7) (N9) (N11)
Plug
Straight piping
Straight piping
Straight piping
Straight piping
Straight piping
Straight piping
Elbow piping∗1
Elbow piping∗1
Elbow piping∗1
Elbow piping∗1
Elbow piping∗1
—— —
——— — ∗2 ∗3 ∗4
— —
— External Individual External
Pilot SUP Pilot
—— — — —
— — — — ∗2 ∗3 ∗4
— — — — — — —
External Individual External
Pilot SUP Pilot
— — —
— —
— — — ∗2 ∗4
— — — — — — — — — — —
— External Individual External
Pilot SUP Pilot
— — — —
— —
— — ∗3 ∗4
— — — — — ———————— ——— —
— External Individual External
Pilot SUP Pilot
— —
— —
— — ∗3
— — — — — ———————— ——— — — — —
— Individual
SUP
— —
— —
— — ∗4
— — — — — — ———————— ——— —— —
— External Individual External
Pilot SUP Pilot
— — —
∗3
————————————— — ———————————— — — — —
External External
Pilot Pilot
∗1 For elbow piping, the size can only be specified in millimeters for certain port sizes. Refer to “How to Order Manifolds” for details.
∗2 Refer to the “Manifold Specifications” on page 39 for details on IP67.
∗3 Only the SY5000/7000 applies.
∗4 Only the SY3000/5000 applies.
One-touch fittings Straight piping Elbow piping
(Upward)
12
C ON T E N T S
Optimum Actuation Size Chart of Air Cylinder ·················································································································· p. 15
Valve Specifications (Specifications, Response Time, Weight) ························································································ p. 17
Valve Construction ···························································································································································· p. 21
Manifold
Plug-in Connector p. 38
Connecting Type 10/ Type 11/ Type 12/
Base Side ported Bottom ported Top ported
EX500 EX500 Gateway Decentralised System (64 Points) [IP67] ····························· pp. 105, 113
EX600 Integrated Type (For Input/Output) Serial Transmission System (Fieldbus System) [IP67] ···· p. 115
EX600
EX245 Integrated Type (For Input/Output) Serial Transmission System [IP65] ····· p. 127
EX245
EX250 Integrated Type (For Input/Output) Serial Transmission System [IP67] ········ p. 134
EX250
EX260 Integrated Type (For Output) Serial Transmission System [IP67] ················· p. 142
EX260
EX126 Integrated Type (For Output) Serial Transmission System [IP67] ················· p. 153
EX126
EX120 Integrated Type (For Output) Serial Transmission System [IP20] ················· p. 161
EX120
EX180 Integrated Type (For Output) Serial Transmission System [IP20] ·············· p. 169
EX180
Type 10/Side Ported: Common Dimensions
(External Pilot, Silencer, Elbow Fittings, Slide Locking Manual Override) ················ p. 177
Manifold Exploded View [Exploded View, Manifold Parts Nos.] ································ p. 290
Sub-plate
14
Optimum Actuation Size Chart of Air Cylinder
Applicable Applicable cylinder
Main valve
cylinder Series
seal type
speed Ø6 Ø 10 Ø 16 Ø 20 Ø 25
SY3000
SY7000
100 mm/s
or less
SY3000
SY7000
SY3000
SY7000
300 mm/s
or less
SY3000
SY7000
SY3000
SY7000
500 mm/s
or less
SY3000
SY7000
[Common conditions]
• Pressure: 0.5 MPa
• Piping length: 1 m
• Load ratio: 50 %
• Stroke: 200 mm
Connector type manifold (for the side and bottom-ported types)
∗ Use as a guide for selection.
Please check the actual conditions with SMC Model Selection Software.
15
Applicable cylinder
16
SY3000/5000/7000 Series
Valve Specifications
Valve Specifications
17
Valve Specifications SY3000/5000/7000 Series
Response Time
18
SY3000/5000/7000 Series
Valve Weight
SY3000 series
Valve model Seal type Type of actuation Weight [g] Valve model Seal type Type of actuation Weight [g]
Single 74 Single 76
2-position 2-position
Double 83 Double 86
Closed centre SY301 Metal seal Closed centre
SY300 Rubber seal
3-position Exhaust centre 87 3-position Exhaust centre 90
Pressure centre Pressure centre
4-position Dual 3-port valve 83
SY5000 series
Valve model Seal type Type of actuation Weight [g] Valve model Seal type Type of actuation Weight [g]
Single 82 Single 91
2-position 2-position
Double 90 Double 101
Closed centre SY501 Metal seal Closed centre
SY500 Rubber seal
3-position Exhaust centre 100 3-position Exhaust centre 111
Pressure centre Pressure centre
4-position Dual 3-port valve 90
19
Valve Specifications SY3000/5000/7000 Series
Valve Weight
SY7000 series
Valve model Seal type Type of actuation Weight [g] Valve model Seal type Type of actuation Weight [g]
Single 110 Single 122
2-position 2-position
Double 118 Double 133
Closed centre SY701 Metal seal Closed centre
SY700 Rubber seal
3-position Exhaust centre 133 3-position Exhaust centre 150
Pressure centre Pressure centre
4-position Dual 3-port valve 114
20
SY3000/5000/7000 Series
Valve Construction
Rubber Seal
2-position single Top ported
(A) (B)
4 2
t e q w r t e q w r
2-position single
5 4 1 2 3 5 1 3 (A)4 2(B)
(EA) (A) (P) (B) (EB) (EA) (P) (EB)
(EA)5 1 3(EB)
(P)
2-position double
t e q w r
2-position double
5 4 1 2 3 (A)4 2(B)
(EA) (A) (P) (B) (EB)
(EA)5 1 3(EB)
(P)
(EA)5 1 3(EB)
(P)
Component Parts
No. Description Material Note
SY3000: Zinc die-casted
1 Body
SY5000/SY7000: Aluminium die-casted
Special resin/HNBR
2 Spool valve
(3-position valve:
Aluminium/HNBR )
3 Piston Resin
Body cover assembly Resin For the side/bottom-ported type
SY3000: Resin
4 SY5000: Zinc die-casted (Thread piping)
Port block assembly For the top-ported type
SY5000: Resin (Fitting)
SY7000: Aluminium die-casted
5 Pilot valve assembly — Refer to page 25.
21
Valve Construction SY3000/5000/7000 Series
Rubber Seal
4-position dual 3-port valve
4-position dual 3-port valve
N.C. valve x 2 pcs. N.O. valve x 2 pcs.
t e q w r 4(A) 2(B) 4(A) 2(B)
2-position double with back pressure check valve (Built-in valve type)
t e q w r
2-position double
with back pressure check valve
(A)4 2(B)
(EA)5 1 3(EB)
(P)
5 4 1 2 3
(EA) (A) (P) (B) (EB)
∗ The built-in valve type back pressure check valve is not available for the SY7000.
4-position dual 3-port valve with back pressure check valve (Built-in valve type)
∗ The built-in valve type back pressure check valve is not available for the SY7000.
22
SY3000/5000/7000 Series
Metal Seal
2-position single Top ported
(A) (B)
4 2
t e q w r t e q w r
2-position single
5 4 1 2 3 5 1 3 (A)4 2(B)
(EA) (A) (P) (B) (EB) (EA) (P) (EB)
(EA)5 1 3(EB)
(P)
2-position double
t e q w r
2-position double
5 4 1 2 3 (A)4 2(B)
(EA) (A) (P) (B) (EB)
(EA)5 1 3(EB)
(P)
(EA)5 1 3(EB)
(P)
Component Parts
No. Description Material Note
SY3000: Zinc die-casted
1 Body
SY5000/7000: Aluminium die-casted
2 Spool, Sleeve Stainless steel/HNBR
3 Piston Resin
Body cover assembly Resin For the side/bottom-ported type
SY3000: Resin
4 SY5000: Zinc die-casted (Thread piping)
Port block assembly For the top-ported type
SY5000: Resin (Fitting)
SY7000: Aluminium die-casted
5 Pilot valve assembly — Refer to page 25.
23
SY3000/5000/7000 Series
Valve Replacement Parts
How to Order Port Block Assembly
Mounting screw
SY 0V 6A One-touch fitting
24
SY3000/5000/7000 Series
Mounting screw
Part no.
Series Standard (Valve mounting Drop prevention type
screw without drop prevention) valve mounting screw
Internal pilot SY30V-16A SY30V-16A-1
SY3000
External pilot SY30V-16AR SY30V-16AR-1
Internal pilot SY50V-16A SY50V-16A-1
SY5000
External pilot SY50V-16AR SY50V-16AR-1
Internal pilot SY70V-16A SY70V-16A-1
SY7000
External pilot SY70V-16AR SY70V-16AR-1
∗ The part number is not indicated on the product.
How to Order Pilot Valve Assembly (With a gasket and two mounting screws)
Coil type
w
— Standard Pilot cover
T With power saving circuit
Socket
Rated voltage q w
5 24 VDC
b-side pilot valve
6 12 VDC
B tight flat head screw (M1.7)
Tightening torque: 0.12 N·m Pilot valve mounting screw (M2 x 16.5)
Caution Tightening torque: 0.15 N·m
1. The coil specification and voltage (including
light/surge voltage suppressor) cannot be
changed by changing the pilot valve Pilot valve mounting screw (M2 x 25)
assembly. Tightening torque: 0.15 N·m
2. When selecting the coil type with power
saving circuit, it is not possible to change to • Loosen B tight flat head screw to remove the pilot cover in the direction
high pressure/power saving circuit type.
indicated by the arrow q.
• Remove the pilot valve mounting screws.
• Remove the pilot valve in the direction indicated by the arrow w.
∗ Assemble by following the removal procedure in reverse.
∗ Ensure the gasket is mounted, and take care not to bend the socket.
∗ Be noted for mounting that there are two types of lengths for the pilot valve mounting
screws.
25
SY5000/7000 Series RoHS
SY 5 3 0 0 5 1 E
Series q w e r t y Thread type
5 SY5000
7 SY7000 Base mounted Port size
(The top-ported type is not available.)
Type of actuation Port location
3 3-position closed centre∗1 With residual pressure release valve
E With residual pressure release valve∗1
∗1 Only the closed centre type is available.
∗1 Mounting screw types, hexagon socket head cap screw Wiring specification
B and drop prevention type K, H are not available. With sub-plate
∗ Make selections for items
Protective class 15 to 18 on page 306.
class # (Mark: ) With sub-plate
w Pilot valve option on the manifold wiring type. Refer to the “How type
to Order Manifolds” pages.
— Standard (0.7 MPa)
B
K∗1
Quick response type (0.7 MPa)
High pressure type (1.0 MPa)
t Light/surge voltage suppressor
and common specification E: F:
∗1 Only the metal seal type is available for the Push-turn Slide locking
high pressure type. Surge voltage Common locking lever type
Symbol With light
suppressor specification
e Coil type — — —
type
— Standard R — Non-polar
T With power saving circuit (Continuous duty type) U
∗ Be sure to select the power saving circuit type S — Positive ∗ Refer to page 36 for the safety slide locking
if the valve is to be continuously energised for Z common manual override.
long periods of time. NS — Negative ∗ When ordering a valve individually, the
∗ Be careful of the energising time when the
NZ common base gasket is not included.
power saving circuit is selected. Refer to page
∗ For the non-polar type, be careful of surge Since the base gasket is attached to the
316 for details.
voltage intrusion. Refer to page 317 for details. manifold, please order the base gasket
∗ Only “Z” and “NZ” types are available with a separately if it is needed for maintenance.
power saving circuit. Refer to page 222 or 290 for base gasket part
numbers.
Refer to Table 1 for mounting screw part
numbers.
26
SY3000/5000/7000 Series
Dimensions
SY5000
47.6
45.1
(For E type: 60.2)
62.3 (For F type)
Exhausted: Concave
30.1
Pressurised: End face
56.6
B A
B side indicator (Red)∗1
51.3
(For E type: 60.2)
62.3 (For F type)
45.5
Exhausted: Concave
33.3
27
SY3000/5000 Series RoHS
Only for
External Pilot Vacuum Release Valve with Restrictor
Mountable manifold [External pilot]
SS5Y3/5-50/52 type manifold
SS5Y3/5-(M)10/11/12 type manifold
Sub-plate single unit (Except SS5Y3-11 type) How to Order (With mounting screw)
Thread type
Port size
Side ported/
Bottom ported SY 3 A 0 R 5 1
Top ported SY 3 A 3 R 5 1 C6
Port location
q w e r t y u i Wiring specification
With sub-plate
∗ Make selections for items 15 to 18 on page 306.
With sub-plate
SS5Y3-10F1-05DR-C6···1 set (Type 10 5-station manifold base part no.) — Round head combination screw
∗SY3A0R-5U1 (3-position 3-port with restrictor part no.)····5 sets B Hexagon socket head cap screw
The asterisk denotes the symbol for the assembly. ∗ When ordering a valve individually, the base gasket is not included.
Prefix it to the part numbers of the valve, etc. Since the base gasket is attached to the manifold, please order the
base gasket separately if it is needed for maintenance.
• For the valve arrangement, the valve closest to the D side is considered the 1st station. Refer to page 222 or 290 for base gasket and mounting screw part
• Under the manifold part number, state the valves to be mounted in order starting
numbers.
with the 1st station as shown in the figure above. If the arrangement becomes
∗ “B” and “H” cannot be selected for the individual SUP/EXH spacer
too complicated, specify the details on a manifold specification sheet.
assembly or interface regulator.
28
SY3000/5000 Series
Valve Specifications
Valve construction 3-position 3-port valve with restrictor
Seal Rubber seal
Fluid Air
Type of actuation Normally closed
Release pressure port 1(P) 0 to 0.6
Operating pressure
Vacuum pressure port 3(EB), 3/5(E) -100 kPa to 0.7∗1
range [MPa]
Pilot X port Release pressure + 0.1 or more (Min. 0.25) to 0.7
Restrictor operation Manual
∗1 Can be used with positive pressure to suit the application
∗ Other specifications are common to the valve specifications on page 17.
∗ Quick response type is not available.
Weight
Valve model Weight [g]
SY3A0R 90
Port size
Valve model Weight [g]
2(B) port
C4 91
SY3A3R
C6 93
Valve model Weight [g]
SY5A0R 94
Port size
Valve model Weight [g]
2(B) port
Symbol
C4 118
2(B)
Vacuum pad port SY5A3R C6 115
C8 121
29
Only for External Pilot Vacuum Release Valve with Restrictor SY3000/5000 Series
500 500
Flow rate [L/min (ANR)]
100 100
0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Number of restrictor rotations Number of restrictor rotations
SY3A3R-C4 SY5A3R-C4
500 500
Flow rate [L/min (ANR)]
400 400
0.6 MPa 0.6 MPa
0.45 MPa 0.45 MPa
300 300
0.3 MPa 0.3 MPa
0.15 MPa 0.15 MPa
200 200
100 100
0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Number of restrictor rotations Number of restrictor rotations
SY3A3R-C6 SY5A3R-C6
500 500
Flow rate [L/min (ANR)]
200 200
100 100
0 0
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Number of restrictor rotations Number of restrictor rotations
SY5A3R-C8
500
Flow rate [L/min (ANR)]
100
0
0 1 2 3 4 5 6
Number of restrictor rotations
30
SY3000/5000 Series
Circuit Example
<Example 1: When the 2-position double solenoid valve is combined with the individual EXH spacer>
Individual EXH spacer
D side U side
5(EA) 5(EA)
(Release pressure port) 1(P) 1(P)
3(EB) 3(EB)
X X
(SY3200) (SY3200) (SY3A0R) (SY3A0R) (SY3A0R)
Vacuum release valve
with restrictor
SOL.b
SOL.b
SOL.b
solenoid valve
SOL.a
SOL.a
SOL.a
4(A) 2(B) 4(A) 2(B) 3/5(E') 3/5(E') 3/5(E')
2(B) Vacuum pressure port 2(B) Vacuum pressure port 2(B) Vacuum pressure port
Vacuum pad port Vacuum pad port Vacuum pad port
<Example 2: When the 2-position double solenoid valve is combined with the individual EXH block and blocking disk>
D side U side
5(EA) 5(EA)
(Release pressure port) 1(P) 1(P)
3(EB) 3(EB)
X X
(SY3200) (SY3A0R) (SY3A0R) (SY3200)
Vacuum release valve
Individual EXH block
2-position double
with restrictor ( EXH block)
Individual
2-position double
solenoid valve
solenoid valve
SOL.b
SOL.b
SOL.a
SOL.a
31
Only for External Pilot Vacuum Release Valve with Restrictor SY3000/5000 Series
Dimensions: SY3000
Side ported SY3A0R
10 1.2 Restrictor
52.5
(For E type: 60.2)
62.3 (For F type)
30.1
28.4
56.6
83.2
51.1
26.8 12.9
31.8
A
9.4
B
Restrictor
10 1.2 ( Tightening torque of needle valve lock
)
(3.2)
30.1
28.4
56.6
83.2
51.1
26.8 12.9
11 20.8
A
9.4
B
32
SY3000/5000 Series
Dimensions: SY5000
Side ported
SY5A0R
Bottom ported
Restrictor
1.3 15
( Tightening torque of needle valve lock
nut should not exceed 0.3 N·m. )
30.1
27.6
56.6
103.4
71.3
(Light/surge voltage suppressor) 39.8 17.5
44.7
1.3
12.6
BA
15
Manual override
2 x Ø 3.2
( Push-turn locking slotted type:
Press, then rotate it. ) (For manifold mounting)
4(A): Blue
2(B): Yellow
30.1
27.6
56.6
103.4
71.3
(Light/surge voltage suppressor)
39.8 17.5
14.5 30.2
1.3
12.6
BA
15
33
RoHS
SY5000/7000 Series
Valve with Pressure Sensor
Mountable manifold
Metal base: SS5Y5/7-50/51 type manifold
Connector connecting base: SS5Y5/7-10/11 type manifold How to Order Valves (With mounting screw))
SY 5 1 3 0 5 1 C6 P2
q w e r t y u i o !0 !1 !2 !3
Top ported
q Series o Light/surge voltage suppressor !1 A, B port size
5 SY5000 and common specification One-touch fitting (Metric)
7 SY7000 Surge voltage Common Symbol A, B port SY5000 SY7000
Symbol With light
suppressor specification C6 Ø6
w Type of actuation — — —
1 2-position
Single R
U
—
Non-polar
!2 Type of mounting screw
2 Double
— Round head combination screw
3 Closed centre S — Positive
B Hexagon socket head cap screw
4 3-position Exhaust centre Z common
Round head combination screw
5 Pressure centre NS — Negative K (Drop prevention type)
A∗1 N.C./N.C. NZ common
Hexagon socket head cap screw
4-position
B∗1 dual 3-port
N.O./N.O. ∗ For the non-polar type, be careful of surge volt- H (Drop prevention type)
C∗1 N.C./N.O. age intrusion. Refer to page 317 for details.
∗ For “K” and “H,” the valve body cover has a
∗1 Only the rubber seal type is available for the ∗ Only “Z” and “NZ” are available with a power
drop prevention construction to stop the
4-position dual 3-port valve. saving circuit.
mounting screws from falling out when the
∗ Select “R,” “U,” “S,” or “Z” for the valve when the
valve is removed for maintenance, etc.
e Seal type SI unit output polarity is positive common.
Select “R,” “U,” “NS,” or “NZ” for the valve when
∗ When ordering a valve individually, the
0 Rubber seal base gasket is not included.
the SI unit output polarity is negative common.
1 Metal seal Since the base gasket is attached to the
r Pilot type !0 Manual override manifold, please order the base gasket sepa-
rately if it is needed for maintenance. Refer to
— Internal pilot —: D: page 222 for base gasket and mounting
Non-locking Push-turn screw part numbers
R External pilot
push type locking ∗ “B” and “H” cannot be selected for the individ-
t Back pressure check valve
(Built-in valve type)
slotted
type
ual SUP/EXH spacer assembly or interface
regulator.
—
H
None
Built-in !3 Pressure sensor
E: F: Symbol Included quantity
∗ Only the rubber seal type is available. A mani-
fold installed type is available if a back pres- Push-turn Slide locking P1 1 pc.
sure check valve with a metal seal is required. locking type P2 2 pcs.
Refer to page 2 3 6 for ordering examples. lever ∗ The top-ported type valve and the C 6 (Ø 6 )
However, it is not recommended to use the type One-touch fitting are used.
built-in valve type and the manifold installed ∗ The PSE 5 4 0 -R 0 6 pressure sensor is
type at the same time because it will reduce included in the product package.
the flow. ∗ When “P1” is selected, one plug (KQ2P-06) is
∗ The built-in valve type back pressure check valve is included in the product package.
not available for the 3-position type or the SY7000.
SS5Y5-10F1-05D-C8 ide
Ds
· For the valve arrangement, the valve closest to the D side is considered the 1st station.
i Rated voltage · Under the manifold part number, state the valves to be mounted in order starting with the 1 st station as shown in the
figure above. If the arrangement becomes too complicated, specify the details on a manifold specification sheet.
5 24 VDC
6 12 VDC
∗ The applicable rated voltage varies depending
on the manifold wiring type.
34
SY5000/7000 Series
Model PSE540
Rated pressure range 0 to 1 MPa∗1
Power supply voltage 12 to 24 VDC ±10 %, Ripple (p-p) 10 % or less (with reverse connection protection)
Current consumption 15 mA or less
Output specifications Analogue output 1 to 5 V (within rated pressure range), 0.6 to 1 V (within extension analogue output range), Output impedance: Approx. 1 k Ω
Linearity ±0.7 % F.S. or less
Environment Enclosure∗2 IP40
Temperature characteristics ±2 % F.S. (25 °C reference)
Sensor cable Oilproof heavy-duty vinyl cable (ellipse), 3 cores, 2.7 x 3.2, 3 m, Conductor area: 0.15 mm2, Insulator O.D.: 0.9 mm
∗1 Set the pressure within the operating pressure range of the valve.
∗2 Please note that even if the manifold is IP67, the product will remain IP40.
Dimensions
3000 3000
68
63
62.3 (For F type)
(For E type: 60.2)
33.6
30.1
27.6
56.6
37.4
50.6 (For 3-position)
103.4
71.3
39.8 17.5
(Light/surge voltage suppressor) 14.5
12.6
B A
3000 3000
71.1
66.1
(For E type: 60.2)
(For F type: 62.3)
33.3
31.3
37
56.6
45.6
62.1 (For 3-position)
116.7
84.6
(Light/surge voltage suppressor) 47 20.6
28.4 3 x Ø 3.2
(For manifold mounting)
16.8
B A
(
Push-turn locking slotted type:
Press, then rotate it. ) 101.1 (For 3-position)
4(A) port side : Blue (For rubber seal) 133.2 (For 3-position)
: Grey (For metal seal)
2(B) port side : Yellow
35
SY3000/5000/7000 Series
Made to Order
Please contact SMC for detailed dimensions, specifications, and lead times.
Symbol
1 Main Valve Fluororubber Specification -X90
Fluororubber is used for rubber parts of the main valve to allow use in applications such as the following.
· When using a lubricant other than the recommended turbine oil, and there is a possibility of malfunction due to swelling of the spool valve seals.
Applicable valves series SY3 03 0, SY5 03 0, SY7 03 0 (Only rubber seal type)
3 0
SY 5 3 0 1 X90
7
Symbol
2 With Safety Slide Locking Manual Override -X13
A safety lock is added to the slide locking manual override.
(Refer to page 4.)
3 00
SY 5 31 G1 X13
7
Symbol
3 2-Position Single Solenoid Valve with Built-in Return Spring (Only rubber seal type) -X350
A 2-position single solenoid valve with a spring built into the main valve
The main valve returns to origin (the OFF position) via the spring when it is not pressurised.
3 0
SY 5 1 3 0 1 X350
7
∗ For the external pilot type, exhaust the external pilot (X) port and the main pressure
simultaneously. (EA)5 1 3(EB) (EA)5 1 3(EB)
If the main pressure cannot be exhausted due to the system specifications, (P) (P)
please contact SMC separately.
36
37
Plug-in Connector Connecting Base
Side ported
Bottom ported
Top ported
38
SY3000/5000/7000 Series Type 10, 11, 12
Plug-in Connector Connecting Base
Manifold Specifications
( ) (( ))
IP67∗1 IP67∗1 EX260 D-sub
EX500 GW communication
Enclosure (Based on IEC60529) IP40 IP67∗1 IP40 IP67∗1
( )
I/O Unit:
partially
IP40
IP65 Unit, Input connector: IP40
Unit: IP65 EX500 GW
Unit: IP65
IP20
∗1 In the case of a metal seal, there are restrictions in the operating environment. Refer to the “Specific Product Precautions” on page 314.
39
Type 10, 11, 12
Plug-in Connector Connecting Base SY3000/5000/7000 Series
41
Type 10, 11, 12
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Single solenoid valve is installed to all double wiring. (in the case of all double wiring)
(Manifold specification sheet is not necessary.)
Solenoid Connector side
(D-sub connector, etc.)
Common (+, –)
SOL.a
Station 1
SOL.b
SOL.a Station 2
Unused terminal
SOL.a Station 3
SOL.b
···
Double solenoid Single solenoid Double solenoid
Station 3 (Double wiring) Station 1
Station 2
Common (+, –)
SOL.a Station 1
SOL.b
SOL.a Station 2
SOL.a
SOL.b Station 3
···
∗ These diagrams are for the purpose of explanation, and differ from the connector wiring used for testing.
42
Plug-in Connector Connecting Base
Type 10
Side Ported D-sub Connector Flat Ribbon Cable
Type 11
Bottom Ported
SY3000/5000/7000 Series ®
RoHS
How to Order Manifolds
t Valve stations
F/FW: D-sub connector (25 pins) P: Flat ribbon cable (26 pins)
Symbol Stations Note Symbol Stations Note
How to Order Manifold Assembly 02 2 stations 02 2 stations
Double wiring∗1 Double wiring∗1
…
12 12 stations 12 12 stations
Example (SS5Y3-10F1-) 02 2 stations Specified layout∗2 02 2 stations Specified layout∗2
2-position double (24 VDC)
…
09 9 stations 04 4 stations
LOC 02 2 stations Specified layout∗2 02 2 stations Specified layout∗2
ide
K
…
…
∗ 3/5(E) port is plugged for the BA — than the total length
built-in silencer type. D — — 24 For 24 stations of specified stations.
DIN rail
A
mounting
B —
∗ Enter the number of stations inside when it is larger than the number
of valve stations. (Refer to “DIN Rail Option” above.)
∗ Only direct mounting is available for the type 11 bottom-ported type.
∗ Refer to page 319 for the fixation of DIN rail mounting type manifold.
C4 Ø4 — — N7 Ø 1/4"
Straight
C6 Ø6 N9 Ø 5/16" —
C8 Ø8 — N11 Ø 3/8" — — —
C10 Ø 10 — — — CM∗1 Straight port, mixed sizes
C12 Ø 12 — — — LN3 Ø 5/32" — — — —
Upward
Elbow∗2
L8 Ø8 — — — BN3 Ø 5/32" — — — —
Downward
B4 Ø4 — — — BN11 Ø 3/8" — — — —
Downward
Protective class
class # (Mark: )
44
SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted
w Type of actuation
1 Single
2
2-position
Double u Coil type E:
Push-turn
F:
Slide locking
3 Closed centre — Standard locking lever type
4 3-position Exhaust centre T With power saving circuit (Continuous duty type) type
5 Pressure centre ∗ Be sure to select the power saving circuit
A∗1 4-position N.C./N.C. type if the valve is to be continuously
B∗1 dual N.O./N.O. energised for long periods of time.
C∗1 3-port N.C./N.O. ∗ Be careful of the energising time when the ∗ Refer to page 36 for the safety slide locking
power saving circuit is selected. Refer to page manual override.
∗1 Only the rubber seal type is available for the 316 for details.
4-position dual 3-port valve.
Protective class
class # (Mark: )
45
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
C2
U
SS5Y3-10F 12 - Stations D - C3, N1
C4, N3 (D)
B C6, N7
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 2
(Station 1)---(Station n) : Ø 3.2, Ø 1/8"
6.1 : Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
1 P 1 P
(62.7)
63.1
13.6
10.6
56.6
48.6
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2
21.6
4 A4 A4 A4 A4 A
18
(11.8)
(Pitch)
[1(P), 3/5(E) port] 31.4 15.5 P = 10.5 (17.8)
Applicable tube O.D.: Ø 8, Ø 5/16"
(8)
LOCK
B A B A B A B A B A
(35)
92.6
14 A 14 A 14 A 14 A 14 A
70.6
83
60.5
FREE
(40.9)
44.8
4.6
12 B 12 B 12 B 12 B 12 B
2 x M2.6
4.6
9.5
1.7
N7: 7.4 )
(4.9)
3.6
2 x 4-40 UNC
(Connector entry
4 x M4 mounting hole [4(A), 2(B) port:
(C6:
∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10F2-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 88.6 99.1 109.6 120.1 130.6 141.1 151.6 162.1 172.6 183.1 193.6 204.1 214.6 225.1 235.6 246.1 256.6 267.1 277.6 288.1 298.6 309.1 319.6
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 123 135.5 148 160.5 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 298 298 310.5 323 335.5 348 360.5
L4 112.5 125 137.5 150 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275 287.5 287.5 300 312.5 325 337.5 350
L5 20.5 21.5 22.5 23.5 18 19 20 21 22 23 18 19 20 21 22 23 23.5 18.5 19.5 20.5 21.5 22.5 23.5
46
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C4, N3
SS5Y5-10F 12 - Stations D - C6, N7 (D)
B C8, N9
One-touch fitting
[4(A), 2(B) port]
(Station 1)----------- (Station n) Applicable tube O.D.: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
6.1
14.1
1 P 1 P
73.2
(62.7)
8.7
2 B2 B2 B2 B2 B
56.6
48.6
12.4
33.4
3/5 E 3/5 E
29.1
4 A4 A4 A4 A4 A
One-touch fitting
mounting)
[1(P), 3/5(E) port] (Pitch)
(11.8)
Applicable tube O.D.: Ø 10, Ø 3/8" 35.9 18 P = 16 (20.5)
(
JIS-X-5101
)
Applicable connector: D-sub MIL-C-24308 equivalent
D side U side
Manual override ∗1
(L5) L1
DIN rail holding screw
(For DIN rail mounting) (8)
( Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor)
: Grey (For metal seal)
DIN rail 2(B) port side : Yellow
(5.5)
(8)
LOCK
BA BA BA BA BA
(35)
70.6
14 A 14 A 14 A 14 A 14 A
97.5
113.4
FREE
81.2
(61.7)
65.6
5.5
12 B 12 B 12 B 12 B 12 B
10.9
30.3
4.7
2 x M2.6
(5.9)
(8.3)
4 x M5 mounting hole
2 x 4-40 UNC
21.9 L2 1.5 (Fitting for the type with P/E [4(A), 2(B) port:
ports on the U and/or D sides) N (inch size)]
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5) (Connector entry upward direction)
(L3)
∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10F2-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 108.4 124.4 140.4 156.4 172.4 188.4 204.4 220.4 236.4 252.4 268.4 284.4 300.4 316.4 332.4 348.4 364.4 380.4 396.4 412.4 428.4 444.4 460.4
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 148 160.5 173 198 210.5 223 235.5 260.5 273 285.5 298 323 335.5 348 373 385.5 398 410.5 435.5 448 460.5 485.5 498
L4 137.5 150 162.5 187.5 200 212.5 225 250 262.5 275 287.5 312.5 325 337.5 362.5 375 387.5 400 425 437.5 450 475 487.5
L5 23 21 19.5 24 22 20.5 18.5 23 21.5 19.5 18 22.5 20.5 19 23.5 21.5 20 18 22.5 21 19 23.5 22
47
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C6, N7
SS5Y7-10F 12- Stations DB - C8,
C10, N11(D)
N9
C12
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 6, Ø 1/4"
(Station 1) (Station n) : Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
: Ø 12
6.1
2
82.7
1 P 1 P
2 B2 B2 B2 B2 B
(62.7)
56.6
48.6
14.2
11.1
3/5 E 3/5 E
35.2
8.7
31.6
4 A4 A4 A4 A4 A
(10)
One-touch fitting (21.7)
mounting)
(14.3)
[1(P), 3/5(E) port] 39.5 20.5 P = 19
Applicable tube O.D.: Ø 12, Ø 1/2"
JIS-X-5101
D side U side
Applicable connector: D-sub
( MIL-C-24308 )
equivalent
Manual override ∗1
DIN rail holding screw (L5) L1
(For DIN rail mounting)
(8) (Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor) : Grey (For metal seal)
2(B) port side : Yellow
(8)
(DIN rail)
LOCK
B A B A B A B A B A
(35)
14 A 14 A 14 A 14 A 14 A
70.6
128.8
115
FREE
(5.5)
96.7
(77.1)
79.5
44.2
12 B 12 B 12 B 12 B 12 B
5.5
8.8
3.9
2 x M2.6
(6)
(9.3)
2 x 4-40 UNC
(17.9)
∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10F2-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 121.2 140.2 159.2 178.2 197.2 216.2 235.2 254.2 273.2 292.2 311.2 330.2 349.2 368.2 387.2 406.2 425.2 444.2 463.2 482.2 501.2 520.2 539.2
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 160.5 173 198 210.5 235.5 248 273 285.5 310.5 323 348 360.5 385.5 398 423 435.5 460.5 485.5 498 523 535.5 560.5 573
L4 150 162.5 187.5 200 225 237.5 262.5 275 300 312.5 337.5 350 375 387.5 412.5 425 450 475 487.5 512.5 525 550 562.5
L5 22.5 19.5 22.5 19 22 19 22 18.5 21.5 18.5 21.5 18 21 18 21 17.5 20.5 23.5 20.5 23.5 20 23 20
48
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C2
SS5Y3-10FW 12 - Stations D - C3, N1
C4, N3 (D)
B C6, N7
(Station 1) (Station n)
One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: Ø 2, Ø 1/8"
Applicable tube O.D.: Ø 8, Ø 5/16" : Ø 3, Ø 5/32"
: Ø 4, Ø 1/4"
4.5
:Ø6
1 P 1 P
(61.1)
63.1
56.6
10.6
13.6
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2
4 A4 A4 A4 A4 A
21.6
23
18
(7.5)
(Pitch)
mounting)
(11.8)
48.3 15.5 P=10.5
D side U side
(L5) Manual override∗1
L1
DIN rail holding screw
(15)
(Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor) : Grey (For metal seal) (Connector entry upward direction)
2(B) port side : Yellow
DIN rail
(8)
(5.5)
B A B A B A B A B A
(35)
14 A 14 A 14 A 14 A 14 A
92.6
83
70.6
60.5
(40.9)
38.7
12 B 12 B 12 B 12 B 12 B
4.6
3.4
4.6
1.7
(4.9)
)
C6: 3.6
N7: 7.4
2 x M2.6
4 x M4 mounting hole
(
2 x 4-40 UNC
[4(A), 2(B) port: N (inch size)]
36.5 L2 1.5 (Fitting for the type with P/E
ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)
JIS-X-5101
Applicable connector: D-sub
( MIL-C-24308
equivalent
)
∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10FW2-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 105.5 116 126.5 137 147.5 158 168.5 179 189.5 200 210.5 221 231.5 242 252.5 263 273.5 284 294.5 305 315.5 326 336.5
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 135.5 148 160.5 173 185.5 198 198 210.5 223 235.5 248 260.5 260.5 273 285.5 298 310.5 323 323 335.5 348 360.5 373
L4 125 137.5 150 162.5 175 187.5 187.5 200 212.5 225 237.5 250 250 262.5 275 287.5 300 312.5 312.5 325 337.5 350 362.5
L5 17.5 18.5 19.5 20.5 21.5 22.5 17 18 19 20 21 22 17 18 19 20 21 22 16.5 17.5 18.5 19.5 20.5
49
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C4, N3
SS5Y5-10FW 12 - Stations D- C6, N7 (D)
B C8, N9
(Station 1) (Station n)
One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: Ø 4, Ø 5/32"
Applicable tube O.D.: Ø 10, Ø 3/8" : Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
4.5
14.1
1 P 1 P
73.2
8.7
(61.1)
2 B2 B2 B2 B2 B
56.6
3/5 3/5
33.4
E E
29.1
23
4 A4 A4 A4 A4 A
12.4
(7.5)
mounting)
(20.5)
(11.8)
50 18 P=16
D side U side
Manual override∗1
B A B A B A B A B A
(35)
14 A 14 A 14 A 14 A 14 A
97.5
70.6
113.4
81.2
(61.7)
59.5
5.5
12 B 12 B 12 B 12 B 12 B
24.2
10.9
4.7
(5.9)
(8.3)
2 x M2.6
4 x M5 mounting hole 2 x 4-40 UNC
36 L2 1.5 [4(A), 2(B) port:
(5.3) (Fitting for the type with P/E
(L4) N (inch size)]
ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)
∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10FW2-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 122.5 138.5 154.5 170.5 186.5 202.5 218.5 234.5 250.5 266.5 282.5 298.5 314.5 330.5 346.5 362.5 378.5 394.5 410.5 426.5 442.5 458.5 474.5
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 160.5 173 185.5 210.5 223 235.5 248 273 285.5 298 310.5 335.5 348 360.5 385.5 398 410.5 423 448 460.5 473 498 510.5
L4 150 162.5 175 200 212.5 225 237.5 262.5 275 287.5 300 325 337.5 350 375 387.5 400 412.5 437.5 450 462.5 487.5 500
L5 21.5 19.5 18 22.5 20.5 19 17 21.5 20 18 16.5 21 19 17.5 22 20 18.5 16.5 21 19.5 17.5 22 20.5
50
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C6, N7
SS5Y7-10FW 12 - Stations D - C8, N9 (D)
B C10, N11
C12
2
82.7
1 P 1 P
2 B2 B2 B2 B2 B
(61.1)
56.6
11.1
3/5 E 3/5 E
8.7
35.2
31.6
4 A4 A4 A4 A4 A
23
14.2
(10)
(21.7)
mounting)
(14.3)
55 20.5 P = 19
D side U side
(8)
(DIN rail)
B A B A B A B A B A
(35)
14 A 14 A 14 A 14 A 14 A
70.6
128.8
115
(5.5)
96.7
(77.1)
74.9
12 B 12 B 12 B 12 B 12 B
5.5
39.6
8.8
3.9
(6)
(9.3)
2 x M2.6
(17.9)
∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10FW2-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 136.7 155.7 174.7 193.7 212.7 231.7 250.7 269.7 288.7 307.7 326.7 345.7 364.7 383.7 402.7 421.7 440.7 459.7 478.7 497.7 516.7 535.7 554.7
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 173 185.5 210.5 223 248 260.5 285.5 298 323 335.5 360.5 385.5 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5
L4 162.5 175 200 212.5 237.5 250 275 287.5 312.5 325 350 375 387.5 412.5 425 450 462.5 487.5 500 525 537.5 562.5 575
L5 20.5 17 20 17 20 16.5 19.5 16.5 19.5 16 19 22 19 22 18.5 21.5 18.5 21.5 18 21 18 21 17.5
51
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
C2
P U
SS5Y3-10 PG 12 - Stations D - C3, N1
C4, N3 (D)
PH B C6, N7
One-touch fitting
(Station 1)---(Station n) [4(A), 2(B) port]
Applicable tube O.D.: Ø 2
18.8
: Ø 3.2, Ø 1/8"
: Ø 4, Ø 5/32"
1 P 1 P
: Ø 6, Ø 1/4"
(75.4)
10.6
13.6
63.1
56.6
48.6
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2
21.6
4 A4 A4 A4 A4 A
18
(Pitch)
mounting)
One-touch fitting 31.4 15.5 P = 10.5 (17.8)
11.8
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 8, Ø 5/16"
D side U side
LOCK
B A B A B A B A B A
5.5
14 A 14 A 14 A 14 A 14 A 92.6
70.6
35
83
60.5
FREE
44.8
40.9
4.6
12 B 12 B 12 B 12 B 12 B
4.6
9.5
1.7
(4.9)
N7: 7.4 )
∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10P2-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.
∗ Only connectors are different for 10PG and 10PH. L1 to L5 dimensions are the same as 10P type.
LOCK
FREE
FREE
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 88.6 99.1 109.6 120.1 130.6 141.1 151.6 162.1 172.6 183.1 193.6 204.1 214.6 225.1 235.6 246.1 256.6 267.1 277.6 288.1 298.6 309.1 319.6
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 123 135.5 148 160.5 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 298 298 310.5 323 335.5 348 360.5
L4 112.5 125 137.5 150 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275 287.5 287.5 300 312.5 325 337.5 350
L5 20.5 21.5 22.5 23.5 18 19 20 21 22 23 18 19 20 21 22 23 23.5 18.5 19.5 20.5 21.5 22.5 23.5
52
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
P U C4, N3
SS5Y5-10 PG 12 - Stations D - C6, N7 (D) One-touch fitting
PH B C8, N9
[4(A), 2(B) port]
Applicable tube O.D.: Ø 4, Ø 5/32"
(Station 1)----------- (Station n) : Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
18.8
(75.4)
14.1
1 P 1 P
73.2
8.7
56.6
2 B2 B2 B2 B2 B
48.6
12.4
33.4
3/5 E 3/5 E
29.1
4 A4 A4 A4 A4 A
mounting)
7.5
(Pitch)
11.8
[1(P), 3/5(E) port] 35.9 18 (20.5)
P = 16
Applicable tube O.D.: Ø 10, Ø 3/8"
D side U side
(L5) Manual override∗1
L1
DIN rail holding screw
(For DIN rail mounting)
(8) (
Push-turn locking slotted type:
Press, then rotate it. ) (Connector entry upward direction)
Light/surge voltage suppressor 4(A) port side : Blue (For rubber seal)
DIN rail : Grey (For metal seal) Triangle mark
2(B) port side : Yellow
8
5.5
LOCK
BA BA BA BA BA
70.6
14 A 14 A 14 A 14 A 14 A
35
97.5
113.4
FREE
81.2
65.6
61.7
5.5
12 B 12 B 12 B 12 B 12 B
30.3
10.9
4 x M5 mounting hole
4.7
(5.9)
(8.3)
“SS5Y5-10P2-05D-C8.”
∗ Refer to page 183 for
FREE
dimensions of A or B port
FREE
top-ported type.
∗ Only connectors are different
for 10PG and 10PH.
L1 to L5 dimensions are the
same as 10P type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 108.4 124.4 140.4 156.4 172.4 188.4 204.4 220.4 236.4 252.4 268.4 284.4 300.4 316.4 332.4 348.4 364.4 380.4 396.4 412.4 428.4 444.4 460.4
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 148 160.5 173 198 210.5 223 235.5 260.5 273 285.5 298 323 335.5 348 373 385.5 398 410.5 435.5 448 460.5 485.5 498
L4 137.5 150 162.5 187.5 200 212.5 225 250 262.5 275 287.5 312.5 325 337.5 362.5 375 387.5 400 425 437.5 450 475 487.5
L5 23 21 19.5 24 22 20.5 18.5 23 21.5 19.5 18 22.5 20.5 19 23.5 21.5 20 18 22.5 21 19 23.5 22
53
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
P U C6, N7
SS5Y7-10 PG D 1 - Stations DB - C8,
PH 2
N9
C10, N11 (D)
C12
One-touch fitting
One-touch fitting (Station 1) (Station n) [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: Ø 6, Ø 1/4"
Applicable tube O.D.: Ø 12, Ø 1/2" : Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
18.8
2
: Ø 12
82.7
1 P 1 P
(75.4)
2 B2 B2 B2 B2 B
56.6
48.6
14.2
3/5 E 3/5 E
11.1
8.7
35.2
31.6
4 A4 A4 A4 A4 A
mounting)
(10)
(14.3)
(21.7)
39.5 20.5 P = 19
(8)
(DIN rail)
LOCK
B A B A B A B A B A
(35)
14 A 14 A 14 A 14 A 14 A
70.6
128.8
115
FREE
(5.5)
96.7
(77.1)
79.5
44.2
12 B 12 B 12 B 12 B 12 B
5.5
8.8
3.9
(6)
(9.3)
Applicable connector:
(A, B port: Ø 12)
(17.9)
LOCK
FREE
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 121.2 140.2 159.2 178.2 197.2 216.2 235.2 254.2 273.2 292.2 311.2 330.2 349.2 368.2 387.2 406.2 425.2 444.2 463.2 482.2 501.2 520.2 539.2
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 160.5 173 198 210.5 235.5 248 273 285.5 310.5 323 348 360.5 385.5 398 423 435.5 460.5 485.5 498 523 535.5 560.5 573
L4 150 162.5 187.5 200 225 237.5 262.5 275 300 312.5 337.5 350 375 387.5 412.5 425 450 475 487.5 512.5 525 550 562.5
L5 22.5 19.5 22.5 19 22 19 22 18.5 21.5 18.5 21.5 18 21 18 21 17.5 20.5 23.5 20.5 23.5 20 23 20
54
Plug-in Connector Connecting Base
D-sub Connector Flat Ribbon Cable
Type 12
SY3000/5000/7000 Series
®
Top Ported
RoHS
How to Order Manifolds
r Valve stations
LOC
K
LOC
K
F/FW: D-sub connector (25 pins) P: Flat ribbon cable (26 pins)
FRE
E
FRE
E
Symbol Stations Note Symbol Stations Note
02 2 stations 02 2 stations
Double wiring∗1 Double wiring∗1
…
…
…
…
PG: Flat ribbon cable PH: Flat ribbon cable 12 12 stations 12 12 stations
(20 pins) (10 pins) 02 2 stations Specified layout∗2 02 2 stations Specified layout∗2
…
…
…
…
(Up to 24 solenoids (Up to 24 solenoids
24 24 stations available) 24 24 stations available)
LOC LOC
PG: Flat ribbon cable (20 pins) PH: Flat ribbon cable (10 pins)
K K
FRE FRE
Symbol Stations Note Symbol Stations Note
E E
02 2 stations 02 2 stations
Double wiring∗1 Double wiring∗1
…
…
…
…
09 9 stations 04 4 stations
t P, E port entry 02 2 stations Specified layout∗2 02 2 stations Specified layout∗2
U∗1 U side (2 to 10 stations) ∗1 y For type “S”, SUP/EXH block
…
…
…
…
(Up to 18 solenoids (Up to 8 solenoids
D∗1 D side (2 to 10 stations) assembly with a built-in silencer, 18 18 stations available) 08 8 stations available)
B Both sides (2 to 24 stations) choose U or D for P, E port entry.
∗1 Double wiring: 2-position single, double, 3-position, and 4-position
valves can be used on all manifold stations.
How to Order Manifold Assembly Use of a 2-position single solenoid will result in an unused control
signal. If this is not desired, order with a specified layout.
∗2 Specified layout: Indicate the wiring specifications on the manifold
Example (SS5Y3-12F1-) specification sheet. (Note that 2-position double, 3-position, and
2-position double (24 VDC) 4-position valves cannot be used where single wiring has been
2-position single (24 VDC) SY3230-5U1-C6 (1 set) specified.)
SY3130-5U1-C6 (3 sets) ∗ This also includes the number of the blanking plate assembly.
3-position closed
centre (24 VDC)
SY3330-5U1-C6 (1 set) y SUP/EXH block assembly i Mounting
— Internal pilot — Direct mounting
Internal pilot, D DIN rail mounting (With DIN rail)
S Built-in silencer D0 DIN rail mounting (Without DIN rail)
LOC
R External pilot D3 For 3 stations Specify a length
…
K
…
ide ∗ The P and E ports are only available longer than that of
FRE
E Us on the U and D sides for the built-in D24 For 24 stations the standard rail.
s
the opposite side of the P and E port fixation of DIN rail mounting
3
Manifold base
type manifold.
2
55
Plug-in Connector Connecting Base SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported
Protective class
class # (Mark: )
56
SY3000/5000/7000 Series
16
17 5
18 option types. 14…………25
6 Socket side
19 7 1 13
20 8 47.04
22
21 9
22 Connector terminal no. Terminal no.
10 Cable
23 11
24 0.3 mm2 x 25 cores 1…………13
12 O.D. Ø 1.4 47.04
25 13
Approx. Ø 10 Cable
0.3 mm2 x 25 cores
O.D. Ø 1.4
Terminal no. Polarity Seal (Length)
015
SOL.a
1 (−) (+) Approx. Ø 8
Molded cover
L
Station 1 SOL.b
14 (−) (+)
SOL.a 2 x M2.6 x 0.45
2 (−) (+)
Station 2 SOL.b or
44
17 (−) (+) 55
SOL.a Connector hood
5 (−) (+)
L
Station 5 SOL.b
18 (−) (+)
SOL.a
6 (−) (+)
Station 6 SOL.b
19 (−) (+)
SOL.a 2 x M2.6 x 0.45
(86.5)
7 (−) (+) or
Station 7 SOL.b
20 (−) (+)
Connector Manufacturer’s Example
2 x 4 − 40 UNC
SOL.a
8 (−) (+) • Fujitsu Limited
Station 8 SOL.b
21 (−) (+) • Japan Aviation Electronics Industry, Limited
SOL.a
8.7
9 (−) (+) • J.S.T. Mfg. Co., Ltd.
Station 9 SOL.b
22 (−) (+) • HIROSE ELECTRIC CO., LTD.
SOL.a
10 (−) (+)
Station 10 SOL.b
23 (−) (+)
SOL.a D-sub connector cable assembly [IP40] D-sub connector cable assembly [IP67]
11 (−) (+)
Station 11 SOL.b
24 (−) (+) Cable Cable
SOL.a
(−) (+) Assembly part no. Note Assembly part no. Note
12 length (L) length (L)
Station 12 SOL.b
25 (−) (+) 1.5 m SY30M-DS25-015
1.5 m AXT100-DS25-015
Cable Cable
3m AXT100-DS25-030 3m SY30M-DS25-030
COM.
(+) (−) 0.3 mm2 x 25 cores 0.3 mm2 x 25 cores
13 5m AXT100-DS25-050 5m SY30M-DS25-050
Positive Negative
common common ∗ When using a standard commercial ∗ Be sure to use the connector cable assembly in
connector, use a 25-pin type female the table, to satisfy enclosure IP67.
∗ When using a valve with no polarity, either positive connector conforming to MIL-C-24308. ∗ Cannot be used for movable wiring
common or negative common can be used. ∗ Cannot be used for movable wiring
∗ Lengths other than the above are also
Terminal Lead wire Dot available. Please contact SMC for details. Electrical characteristics
no. colour marking
Item Property
1 Black None
D-sub connector cable assembly terminal numbers Conductor resistance 65 or
2 Brown None 액/km, 20 °C less
3 Red None Terminal
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Voltage limit
4 Orange None no. 1000
V, 1 minute, AC
White
White
White
Brown
Brown
Orange
Yellow
Yellow
Orange
Yellow
Orange
Purple
Purple
5 Yellow None
Black
Black
Grey
Grey
Grey
Blue
Blue
Pink
Pink
Pink
Lead wire
Red
Red
Insulation resistance 5 or
6 Pink None colour M액/km, 20 °C more
7 Blue None
∗ The minimum bending
White
White
White
White
White
Black
Black
Black
Black
Black
None
None
None
None
None
None
None
None
None
None
Dot
Red
Red
Red
Red
Red
8 Purple White
marking radius of the D-sub
9 Grey Black connector cable is 20 mm.
10 White Black
11 White Red
12 Yellow Red
13 Orange Red Specified Layout
14 Yellow Black (25 pins)
15 Pink Black
16 Blue White A mixture of single and double
17 Purple None 1 wiring can be specified on the
14 2
18 Grey None 15 3
manifold specification sheet. The
16
19 Orange Black 17
4 maximum number of stations is
5
20 Red White 18 6 determined according to the number
19
21 Brown White 20
7 of solenoids. The total number of
8
22 Pink Red 21 9 solenoids should be 24 or less. 1
22 10
23 Grey Red 23 solenoid is required for the
11
24 Black White 24 12 2-position single, and 2 solenoids for
25 13
25 White None the 2-position double, 3-position,
and 4-position.
∗ Connector made in conformity with MIL-C-24308
COM.
57
Plug-in Connector Connecting Base SY3000/5000/7000 Series
20
L
53.5
(−) (+) 11 White Red
2- M2.6
20
SOL. a
8 (−) (+) 12 Yellow Red
Station 8 SOL. b
21 (−) (+) 13 Orange Red
SOL. a
9 (−) (+) 14 Yellow Black
Station 9 SOL. b 22 (−) (+) 25 L
SOL. a 15 Pink Black
10 (−) (+) 41 41
Station 10 SOL. b 23 16 Yellow White
(−) (+)
15.2
Standard
D-Sub connector cable assembly (option)
015
AXT100-DS25- 030 (According to MIL-C24308)
050
58
SY3000/5000/7000 Series
P: Flat ribbon cable (26 pins) PG: Flat ribbon cable (20 pins)
<Double wiring> <Double wiring>
Terminal no. Polarity Terminal no. Polarity
SOL.a 1 (−) (+) SOL.a 1 (−) (+)
Station 1 SOL.b Station 1 SOL.b
2 (−) (+) 2 (−) (+)
SOL.a 3 (−) (+) SOL.a 3 (−) (+)
Station 2 SOL.b Station 2 SOL.b
4 (−) (+) 4 (−) (+)
SOL.a 5 (−) (+) SOL.a 5 (−) (+)
Station 3 SOL.b Station 3 SOL.b
6 (−) (+) 6 (−) (+)
SOL.a 7 (−) (+) SOL.a 7 (−) (+)
Station 4 SOL.b Station 4 SOL.b
8 (−) (+) 8 (−) (+)
SOL.a 9 (−) (+) SOL.a 9 (−) (+)
Station 5 SOL.b Station 5 SOL.b
10 (−) (+) 10 (−) (+)
SOL.a 11 (−) (+) SOL.a 11 (−) (+)
Station 6 SOL.b Station 6 SOL.b
12 (−) (+) 12 (−) (+)
SOL.a 13 (−) (+) SOL.a 13 (−) (+)
Station 7 SOL.b Station 7 SOL.b
14 (−) (+) 14 (−) (+)
SOL.a 15 (−) (+) SOL.a 15 (−) (+)
Station 8 SOL.b Station 8 SOL.b
16 (−) (+) 16 (−) (+)
SOL.a 17 (−) (+) SOL.a 17 (−) (+)
Station 9 SOL.b Station 9 SOL.b
18 (−) (+) 18 (−) (+)
SOL.a 19 (−) (+) COM.
Station 10 SOL.b 19 (+) (−)
20 (−) (+) COM.
SOL.a 20 (+) (−)
21 (−) (+) Positive Negative
Station 11 SOL.b 22 (−) (+) common common
SOL.a 23 (−) (+)
Station 12 SOL.b 24 (−) (+)
COM.
25 (+) (−)
COM.
26 (+) (−)
Positive Negative
common common
59
Plug-in Connector Connecting Base SY3000/5000/7000 Series
1
26
25
(15.6)
L
Specified Layout
COM. COM.
26 25
24 23 COM. COM.
22 21
20 19 20 19
18 17 18 17
16 15 16 15
14 13 14 13 COM. COM.
12 11 12 11
10 9 10 9 10 9
8 7 8 7 8 7
6 5 6 5 6 5
4 3 4 3 4 3
2 1 2 1 2 1
A mixture of single and double wiring can be specified on the manifold specification. The maximum number of stations is determined according to the number of solenoids.
The total number of solenoids should be 2 4 or less for P, 18 or less for PG, and 8 or less for PH. 1 solenoid is required for the 2 -position single, and 2 solenoids for the
2-position double, 3-position, and 4-position.
60
Type 10
Plug-in Connector Connecting Base
Side Ported Terminal Block Box (Spring Type)
Type 11
Bottom Ported
SY3000/5000/7000 Series ®
RoHS
How to Order Manifolds
···
···
Double wiring ∗1 BA Name plate (without station number) longer than that of
···
···
w Type 16 16 stations D
DIN rail
Without name plate
A mounting Name plate (with station number)
24 For 24 stations the standard rail.
10 Side ported 02 2 stations Specified layout ∗2
Bottom ported ∗1
B Name plate (without station number)
···
···
11 (Up to 32 solenoids
24 24 stations available) ∗ Enter the number of stations inside . (Refer to “DIN Rail Option” above.)
∗1 The SY5000 manifold base is used for
∗ Only direct mounting is available for the type 11 bottom-ported type.
the bottom-ported SY3000. When order- ∗1 Double wiring: 2-position sin-
ing, refer to the “Plug-in Manifold Mixed
Mounting Type” (from page 185).
gle, double, 3-position, and
4-position valves can be used
y A, B port size (Metric/One-touch fitting)
on all manifold stations. Type 10/Side ported Type 11/Bottom ported
Symbol A, B port
r P, E port entry Use of a 2-position single so-
C2 Ø2
SY3000 SY5000 SY7000 SY5000 SY7000
— — — —
lenoid will result in an unused
U U side (2 to 10 stations) C3 Ø 3.2 — — — —
control signal. If this is not de-
D D side (2 to 10 stations) C4 Ø4 — —
sired, order with a specified
Straight
∗ 3/5(E) port is plugged for the built-in valves cannot be used where L6 Ø6 — —
silencer type. single wiring has been speci- L8 Ø8 — — —
∗ When the built-in silencer type is used, fied.) L10 Ø 10 — — — —
∗ This also includes the number L12
Elbow ∗2
B6 Ø6 — —
How to Order Manifold Assembly B8 Ø8 — — —
B10 Ø 10 — — — —
B12 Ø 12 — — — —
Example (SS5Y3-10TC-)
LM∗1 Elbow port, mixed sizes (Including
upward and downward piping) — —
2-position double (24 VDC) 3-position closed centre (24 VDC) P, E port size (One-touch fittings) Ø8 Ø 10 Ø 12 Ø 10 Ø 12
SY3200-5U1 (1 set) SY3300-5U1 (1 set)
A, B port size (Inch/One-touch fitting)
2-position single (24 VDC) Type 10/Side ported Type 11/Bottom ported
SY3100-5U1 (3 sets)
Symbol A, B port
SY3000 SY5000 SY7000 SY5000 SY7000
N1 Ø 1/8" — — — —
N3 Ø 5/32" — —
Straight
N7 Ø 1/4"
N9 Ø 5/16" —
N11 Ø 3/8" — — —
e
sid
at
LN3 Ø 5/32" — — — —
St
Downward Upward
LN7
3
Ø 1/4" — — —
2
1
LN9 Ø 5/16" — — — —
e
sid
LN11
Elbow ∗2
SS5Y3-10TC-05D-C6
Ø 3/8" — — — —
BN3 Ø 5/32" — — — —
SS5Y3-10TC-05D-C6 ·····1 set (Type 10 5-station manifold base part no.) BN7 Ø 1/4" — — —
∗ SY3100-5U1 ·················· 3 sets (2-position single part no.) BN9 Ø 5/16" — — — —
∗ SY3200-5U1 ·················· 1 set (2-position double part no.) BN11 Ø 3/8" — — — —
∗ SY3300-5U1 ·················· 1 set (3-position closed centre part no.) LM∗1 Elbow port, mixed sizes (Including
— —
upward and downward piping)
The asterisk denotes the symbol for the assembly. P, E port size (One-touch fittings) Ø 5/16" Ø 3/8" Ø 1/2" Ø 3/8" Ø 1/2"
Prefix it to the part numbers of the valve, etc.
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
• For the valve arrangement, the valve closest to the D side is considered the 1st station. The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,”
• Under the manifold part number, state the valves to be mounted in order indicate it on the manifold specification sheet for the P, E port fitting direction.
starting with the 1st station as shown in the figure above. If the arrangement ∗2 To avoid interference with the body or piping, select a downward elbow port
becomes too complicated, specify the details on a manifold specification sheet.
when mounting the optional spacer assembly.
61
Plug-in Connector Connecting Base SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted
w Type of actuation
1
2-position
Single u Coil type E: F:
2 Double — Standard Push-turn Slide locking
3 Closed centre T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit lever
5 Pressure centre type if the valve is to be continuously type
A∗1 N.C./N.C. energised for long periods of time.
4-position ∗ Be careful of the energising time when the
B∗1 dual 3-port
N.O./N.O.
C∗1 N.C./N.O. power saving circuit is selected. Refer to
∗ Refer to page 36 for the safety slide locking
page 316 for details.
∗1 Only the rubber seal type is available for the manual override.
4-position dual 3-port valve.
i Rated voltage
e Seal type
5
6
24 VDC
12 VDC
!1 Type of mounting screw
— Round head combination screw
0 Rubber seal
B Hexagon socket head cap screw
1 Metal seal
K Round head combination screw (Drop prevention type)
o Light/surge voltage suppressor H Hexagon socket head cap screw (Drop prevention type)
and common specification ∗ For “K” and “H,” the valve body cover has a
r Pilot type Symbol With light
Surge voltage Common drop prevention construction to stop the
mounting screws from falling out when the
— Internal pilot suppressor specification
valve is removed for maintenance, etc.
R External pilot — — —
∗ When ordering a valve individually, the
R — Non-polar base gasket is not included.
U Since the base gasket is attached to the
S — Positive manifold, please order the base gasket
t Back pressure check valve Z
common separately if it is needed for maintenance.
(Built-in valve type) NS — Refer to page 222 for base gasket and
Negative
mounting screw part numbers.
— None NZ common
∗ “B” and “H” cannot be selected for the
H Built-in ∗ For the non-polar type, be careful of surge individual SUP/EXH spacer assembly,
∗ Only the rubber seal type is available. A voltage intrusion. interface regulator, or double check spacer
manifold installed type is available if a back Refer to page 317 for details. assembly with residual pressure release
pressure check valve with a metal seal is ∗ Only “Z” and “NZ” types are available with a valve.
required. Refer to page 236 for ordering power saving circuit.
examples. However, it is not recommended
to use the built-in valve type and the manifold
installed type at the same time because it will
reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.
Protective class
class # (Mark: )
62
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C2
SS5Y3-10TC- Stations DB - C3, N1
C4, N3 (D)
C6, N7
(Station 1) (Station n)
manual override)
(Slide locking
1 P 1 P
21.6
68.8
10.6
13.6
71
63.1
56.6
3/5 S 3/5
E 2 B2 B2 B2 B2 B E
40.2
(11.8)
31.5
4 A4 A4 A4 A4 A
(7.5)
18
D side U side
Manual override
DIN rail holding screw
(For DIN rail mounting) (
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
(DIN rail)
: Grey (For metal seal)
(8) 2(B) port side: Yellow Plug
(5)
(5.5)
(35)
B A B A B A B A
102.6
92.6
14 A 14 A 14 A 14 A
83
60.5
(40.9)
12 B 12 B 12 B 12 B
4.6
1.7
5
4.6
(N7: 7.4)
(4.9)
C6: 3.6
4 x M4 Mounting hole
Silencer (Exhaust port)
(Recommended tightening torque: 1.4 N·m)
(Built-in silencer specification)
(Fitting for the type with P/E ports on
74 L2 1.5 the U or both sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 143 153.5 164 174.5 185 195.5 206 216.5 227 237.5 248 258.5 269 279.5 290 300.5 311 321.5 332 342.5 353 363.5 374
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 173 185.5 198 210.5 223 235.5 235.5 248 260.5 273 285.5 298 298 310.5 323 335.5 348 360.5 360.5 373 385.5 398 410.5
L4 162.5 175 187.5 200 212.5 225 225 237.5 250 262.5 275 287.5 287.5 300 312.5 325 337.5 350 350 362.5 375 387.5 400
L5 17.5 18.5 19.5 20.5 21.5 22.5 17 18 19 20 21 22 17 18 19 20 21 22 16.5 17.5 18.5 19.5 20.5
63
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C4, N3
SS5Y5-10TC- Stations DB - C6, N7 (D)
C8, N9
(Station 1) (Station n)
manual override)
(Slide locking
12.4
78.9
1 P 1 P
14.1
73.2
S
8.7
71
2 B2 B2 B2 B2 B
56.6
3/5
(11.8)
33.4
3/5 E E
31.5
29.1
(7.5)
4 A4 A4 A4 A4 A
87.5 18 (20.5)
(Pitch)
16.5 P = 16 One-touch fitting
[4(A), 2(B) port]
Applicable tubing O.D. C4: Ø 4 (SMC)
2 x M20 x 1.5 thread depth 13
C6: Ø 6 (SMC)
(Conduit port) C8: Ø 8 (SMC)
N3: Ø 5/32" (SMC)
N7: Ø 1/4" (SMC)
N9: Ø 5/16" (SMC)
D side U side
DIN rail holding screw Manual override
(L5)
(For DIN rail mounting)
L1 (
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
(DIN rail) : Grey (For metal seal) Plug
(5)
B A B A B A B A
14 A 14 A 14 A 14 A
118.4
113.4
97.5
81.2
(61.7)
(35)
10.9
5.5
12 B 12 B 12 B 12 B
4.7
(5.9)
(8.3)
4 x M5 Mounting hole
73.5 L2 1.5 (Recommended tightening torque: 2.9 N·m)
(5.3) (L4) (Fitting for the type with P/E ports on
the U or both sides)
(DIN rail mounting hole pitch: 12.5)
(L3)
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432 448 464 480 496 512
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 198 210.5 223 248 260.5 273 285.5 310.5 323 335.5 348 373 385.5 398 423 435.5 448 460.5 485.5 498 510.5 535.5 548
L4 187.5 200 212.5 237.5 250 262.5 275 300 312.5 325 337.5 362.5 375 387.5 412.5 425 437.5 450 475 487.5 500 525 537.5
L5 21.5 19.5 18 22.5 20.5 19 17 21.5 20 18 16.5 21 19 17.5 22 20 18.5 16.5 21 19.5 17.5 22 20.5
64
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C6, N7
SS5Y7-10TC- Stations DB - C8, N9
C10, N11 (D)
C12
manual override)
2
(Slide locking
14.2
85.8
82.7
1 P 1 P
11.1
S
2 B2 B2 B2 B2 B
71
56.6
3/5 E 3/5 E
35.2
8.7
31.5
31.6
4 A4 A4 A4 A4 A
(10)
(14.3)
16.5 (Pitch)
92.5 P = 19 (21.7)
20.5
(
Push-turn locking slotted type:
Press, then rotate it. )
Silencer (Exhaust port) 4(A) port side: Blue (For rubber seal)
(Built-in silencer specification) (8) : Grey (For metal seal) Plug
2(B) port side: Yellow
(5)
B A B A B A B A
14 A 14 A 14 A 14 A
133.8
128.8
115
(5.5)
(35)
96.7
(77.1)
12 B 12 B 12 B 12 B
8.8
3.9
5.5
(6)
(DIN rail)
(N13: 20.4)
(17.9)
(9.3)
4 x M5 Mounting hole
(Recommended tightening torque: 2.9 N·m)
73.7 L2 1.5 (Fitting for the type with P/E ports on
(5.3) (L4) the U or both sides)
(DIN rail mounting hole pitch: 12.5)
(L3) (A, B port: Ø 12)
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 174.2 193.2 212.2 231.2 250.2 269.2 288.2 307.2 326.2 345.2 364.2 383.2 402.2 421.2 440.2 459.2 478.2 497.2 516.2 535.2 554.2 573.2 592.2
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 210.5 223 248 260.5 285.5 298 323 335.5 360.5 373 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5 610.5 623
L4 200 212.5 237.5 250 275 287.5 312.5 325 350 362.5 387.5 412.5 425 450 462.5 487.5 500 525 537.5 562.5 575 600 612.5
L5 20.5 17 20 17 20 16.5 19.5 16.5 19.5 16 19 22 19 22 18.5 21.5 18.5 21.5 18 21 18 21 17.5
65
Plug-in Connector Connecting Base
Terminal Block Box (Spring Type)
SY3000/5000/7000 Series ®
RoHS
How to Order Manifolds
q w e r t y u
q Series e Valve stations r P, E port entry
3 SY3000 TC: Spring type terminal block box U U side (2 to 10 stations)
5 SY5000 Symbol Stations Note D D side (2 to 10 stations)
7 SY7000 02 2 stations B Both sides (2 to 24 stations)
Double wiring ∗1
···
···
16 16 stations
02 2 stations
Specified layout ∗2
w Type t SUP/EXH block assembly
···
···
Example (SS5Y3-12TC-)
y P, E port size
(One-touch fittings)
2-position double (24 VDC) Symbol SY3000 SY5000 SY7000
3-position closed centre (24 VDC)
SY3230-5U1-C6 (1 set) — Ø8 Ø 10 Ø 12
SY3330-5U1-C6 (1 set)
2-position single (24 VDC) N Ø 5/16" Ø 3/8" Ø 1/2"
SY3130-5U1-C6 (3 sets) ∗ For N, sizes are in inches.
u Mounting
— Direct mounting
D DIN rail mounting (with DIN rail)
D0 DIN rail mounting (without DIN rail)
ide
Us D3 For 3 stations Specify a length longer
ns
tatio
···
···
66
SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported
w Type of actuation
high pressure type. 02 1/4 SY7000
Protective class
class # (Mark: )
67
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Gasket
6
Drip-proof plug (SY30M-133-1) Push 4A
5A
h 3A
is mounted Pitc m button
1A
2A
m
Tightening torque: 0.8 N·m 3.5 2B
3
1B
Spring type
Conduit port terminal block
2 x M20 x 1.5
Step 3. Mount the terminal block cover
Securely tighten the mounting screws (M3) to the torque
shown in the table below only after confirming that the
gasket is installed correctly.
SOL.b (+)
6B (−)
SOL.a (+)
7A (−)
Station 7 SOL.b (+)
7B (−)
SOL.a (+)
8A (−)
If alignment is not specified, the Station 8 SOL.b (+)
8B (−)
internal wiring will be double wiring SOL.a (+)
9A (−)
(connected to SOL. a and SOL. b) Station 9 SOL.b
9B (−) (+)
regardless of number of stations, SOL.a
valve types, and option types. 10A (−) (+)
Station 10 SOL.b (+)
10B (−)
SOL.a (+)
11A (−)
Station 11 SOL.b (+)
∗ When using a valve with no 11B (−)
SOL.a (+)
polarity, either positive 12A (−)
common or negative common Station 12 SOL.b (+)
12B (−)
can be used. SOL.a (+)
13A (−)
Station 13 SOL.b (+)
13B (−)
SOL.a (+)
14A (−)
Station 14 SOL.b (+)
14B (−)
SOL.a (+)
15A (−)
Station 15 SOL.b (+)
15B (−)
SOL.a (+)
16A (−)
Station 16 SOL.b (+)
16B (−)
68
Plug-in Connector Connecting Base
Type 10
Side Ported Terminal Block Box
SY3000/5000/7000 Series
Type 11
Bottom Ported
RoHS
How to Order Manifolds
Example (SS5Y3-10T-)
u Mounting and Option
Option
2-position double (24 VDC) Symbol Mounting
Name plate Station number
2-position single (24 VDC) SY3200-5U1 (1 set) — — —
3-position closed Direct
SY3100-5U1 (3 sets) AA
centre (24 VDC) mounting
BA —
SY3300-5U1 (1 set)
D — —
DIN rail
A
mounting
B —
∗ Enter the number of stations inside when it
is larger than the number of valve stations.
ide (Refer to “DIN Rail Option” below.)
Us
s ∗ Only direct mounting is available for the type
ation
St 11 bottom-ported type.
3 ∗ Refer to page 319 for the fixation of DIN rail
2
1 mounting type manifold.
e
D sid
DIN Rail Option
Manifold base
— Standard length
(5 stations)
SS5Y3-10T-05D-C6
0 Without DIN rail (with bracket)
3 For 3 stations
Specify a longer rail than the
…
SS5Y3-10T-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.) total length of specified stations.
∗SY3100-5U1 ··············· 3 sets (2-position single part no.) 20 For 20 stations
∗SY3200-5U1 ··············· 1 set (2-position double part no.)
∗SY3300-5U1 ··············· 1 set (3-position closed centre part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
• For the valve arrangement, the valve closest to the D side is considered the 1st station.
• Under the manifold part number, state the valves to be mounted in order starting
with the 1st station as shown in the figure above. If the arrangement becomes too
complicated, specify the details on a manifold specification sheet.
∗ When mixing top-ported configurations, select from those listed on page 76.
In such cases, use caution as there is also output on the A and B ports on the base side.
Specify on the manifold specification sheet if plugs are required for the A and B ports on
the base side.
69
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Straight
C4 Ø4 — — N7 Ø 1/4"
Straight
C6 Ø6 N9 Ø 5/16" —
C8 Ø8 — N11 Ø 3/8" — — —
C10 Ø 10 — — — CM∗1 Straight port, mixed sizes
C12 Ø 12 — — — LN3 Ø 5/32" — — — —
Upward
CM∗1 Straight port, mixed sizes LN7 Ø 1/4" — — —
L4 Ø4 — — — LN9 Ø 5/16" — — — —
L6 Ø6 — — LN11 Ø 3/8" — — — —
Upward
Elbow∗2
L8 Ø8 — — — BN3 Ø 5/32" — — — —
Downward
B4 Ø4 — — — BN11 Ø 3/8" — — — —
Downward
P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).
Protective class
class # (Mark: )
70
SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted
w Type of actuation
1
2-position
Single u Coil type E: F:
2 Double — Standard Push-turn Slide locking
3 Closed centre T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit lever
5 Pressure centre type if the valve is to be continuously type
A∗1 N.C./N.C. energised for long periods of time.
4-position ∗ Be careful of the energising time when the
B∗1 dual 3-port
N.O./N.O.
C∗1 N.C./N.O. power saving circuit is selected. Refer to page
316 for details. ∗ Refer to page 36 for the safety slide locking
∗1 Only the rubber seal type is available for the manual override.
4-position dual 3-port valve.
i Rated voltage
e Seal type
5
6
24 VDC
12 VDC
!1 Type of mounting screw
— Round head combination screw
0 Rubber seal
B Hexagon socket head cap screw
1 Metal seal
K Round head combination screw (Falling-out-prevention type)
o Light/surge voltage suppressor H Hexagon socket head cap screw (Falling-out-prevention type)
and common specification ∗ For “K” and “H,” the valve body cover has a
r Pilot type Symbol With light
Surge voltage Common drop prevention construction to stop the
mounting screws from falling out when the
— Internal pilot suppressor specification
valve is removed for maintenance, etc.
R External pilot — — —
∗ When ordering a valve individually, the
R — Non-polar base gasket is not included.
U Since the base gasket is attached to the
S — Positive manifold, please order the base gasket
t Back pressure check valve Z
common separately if it is needed for maintenance.
(Built-in valve type) NS — Refer to page 222 for base gasket and
Negative
mounting screw part numbers.
— None NZ common
∗ “B” and “H” cannot be selected for the
H Built-in ∗ For the non-polar type, be careful of surge individual SUP/EXH spacer assembly,
∗ Only the rubber seal type is available. A voltage intrusion. interface regulator, or double check spacer
manifold installed type is available if a back Refer to page 317 for details. assembly with residual pressure release
pressure check valve with a metal seal is ∗ Only “Z” and “NZ” types are available with a valve.
required. Refer to page 236 for ordering power saving circuit.
examples. However, it is not recommended
to use the built-in valve type and the manifold
installed type at the same time because it will
reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.
Protective class
class # (Mark: )
71
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
C2
U
SS5Y3-10T- Stations D - C3, N1
C4, N3 (D)
B C6, N7
1 P 1 P
77.7
13.6
10.6
63.1
56.6
45.5
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2
21.6
4 A4 A4 A4 A4 A
18
13.2
11.8
(Pitch)
107.1 15.5 P = 10.5 (17.8)
D side U side
(L5) L1
Manual override ∗1
DIN rail holding screw
(For DIN rail mounting)
DIN rail holding screw
(For DIN rail mounting)
(Push-turn locking slotted type:
Press, then rotate it. )
DIN rail 4(A) port side : Blue (For rubber seal)
Light/surge : Grey (For metal seal)
voltage suppressor 2(B) port side : Yellow
D side
U side
8
B A B A B A B A B A
5.5
14 A 14 A 14 A 14 A 14 A
35
126
83
92.6
80
60.5
40.9
4.6
12 B 12 B 12 B 12 B 12 B
20.4
4.6
1.7
16
)
(4.9)
4 x M4 mounting hole
C6: 3.6
N7: 7.4
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3
∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10T-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L1 164.3 174.8 185.3 195.8 206.3 216.8 227.3 237.8 248.3 258.8 269.3 279.8 290.3 300.8 311.3 321.8 332.3 342.8 353.3
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252
L3 198 198 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 335.5 335.5 348 360.5 373 385.5
L4 187.5 187.5 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 325 325 337.5 350 362.5 375
L5 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12 13 14 15 16
72
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C4, N3
SS5Y5-10T- Stations D - C6, N7 (D)
B C8, N9
One-touch fitting
[1(P), 3/5(E) port] One-touch fitting
Applicable tube O.D.: Ø 10, Ø 3/8" [4(A), 2(B) port]
(Station 1)----------- (Station n) Applicable tube O.D.: Ø 4, Ø 5/32"
2 x G3/4
: Ø 6, Ø 1/4"
Conduit port : Ø 8, Ø 5/16"
14.1
77.7
1 P 1 P
73.2
8.7
2 B2 B2 B2 B2 B
56.6
45.5
33.4
3/5 E 3/5 E
29.1
4 A4 A4 A4 A4 A
13.2
12.4
7.5
11.8
(Pitch)
108.8 18 P = 16 (20.5)
D side U side
U side
8
BA BA BA BA BA
5.5
35
14 A 14 A 14 A 14 A 14 A
126.4
97.5
113.4
80
81.2
61.7
5.5
12 B 12 B 12 B 12 B 12 B
16.4
1
10.9
4.7
(5.9)
(8.3)
2 x M5 mounting hole
4 x M5 mounting hole
7.1 87.7 L2 1.5
(Fitting for the type with P/E
5.3 L4 ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
L3
∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10T-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L1 181.3 197.3 213.3 229.3 245.3 261.3 277.3 293.3 309.3 325.3 341.3 357.3 373.3 389.3 405.3 421.3 437.3 453.3 469.3
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368
L3 210.5 223 248 260.5 273 285.5 310.5 323 335.5 360.5 373 385.5 398 423 435.5 448 460.5 485.5 498
L4 200 212.5 237.5 250 262.5 275 300 312.5 325 350 362.5 375 387.5 412.5 425 437.5 450 475 487.5
L5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14 12.5 17 15 13.5 11.5 16 14.5
73
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
C6, N7
U
SS5Y7-10T- Stations D - C8, N9
C10, N11 (D)
B C12
2
82.7
1 P 1 P
77.7
2 B2 B2 B2 B2 B
56.6
45.5
11.1
3/5 E 3/5 E
8.7
35.2
31.6
4 A4 A4 A4 A4 A
14.2
13.2
mounting)
(Pitch)
(14.3)
113.8 20.5 P = 19
D side U side
DIN rail holding screw DIN rail holding screw (Push-turn locking slotted type:
Press, then rotate it. )
(8)
(For DIN rail mounting) (For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor) : Grey (For metal seal)
2(B) port side : Yellow
D side
U side
(8)
(DIN rail)
B A B A B A B A B A
(35)
14 A 14 A 14 A 14 A 14 A
141.8
80
128.8
115
(5.5)
96.7
(77.1)
12 B 12 B 12 B 12 B 12 B
5.5
31.8
1
8.8
3.9
(6)
(9.3)
2 x M5 mounting hole
(17.9)
∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10T-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L1 195.5 214.5 233.5 252.5 271.5 290.5 309.5 328.5 347.5 366.5 385.5 404.5 423.5 442.5 461.5 480.5 499.5 518.5 537.5
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436
L3 223 248 260.5 285.5 298 323 335.5 360.5 373 398 410.5 435.5 448 473 485.5 510.5 523 548 573
L4 212.5 237.5 250 275 287.5 312.5 325 350 362.5 387.5 400 425 437.5 462.5 475 500 512.5 537.5 562.5
L5 14 17 13.5 16.5 13.5 16.5 13 16 13 16 12.5 15.5 12.5 15.5 12 15 12 15 18
74
Plug-in Connector Connecting Base
Terminal Block Box
SY3000/5000/7000 Series ®
RoHS
How to Order Manifolds
Example (SS5Y3-12T-)
2-position double (24 VDC) y Mounting
SY3230-5U1-C6 (1 set) — Direct mounting
2-position single (24 VDC) 3-position closed DIN rail mounting
SY3130-5U1-C6 (3 sets) centre (24 VDC) D
(With DIN rail)
SY3330-5U1-C6 (1 set) DIN rail mounting
D0
(Without DIN rail)
D3 For 3 stations Specify a length longer
…
ide
Ds
Manifold base
(5 stations)
SS5Y3-12T-05D
SS5Y3-12T-05D ············ 1 set (Type 12 5-station manifold base part no.)
∗SY3130-5U1-C6 ············ 3 sets (2-position single part no.)
∗SY3230-5U1-C6 ············ 1 set (2-position double part no.)
∗SY3330-5U1-C6 ············ 1 set (3-position closed centre part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
• For the valve arrangement, the valve closest to the D side is considered the 1st station.
• Under the manifold part number, state the valves to be mounted in
order starting with the 1st station as shown in the figure above. If the
arrangement becomes too complicated, specify the details on a
manifold specification sheet.
75
Plug-in Connector Connecting Base SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported
w Type of actuation
high pressure type. 02 1/4 SY7000
Protective class
class # (Mark: )
76
SY3000/5000/7000 Series
Gasket
m
6m
Electrical entry
2 x G3/4
1B
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM
SOL.a
1B 2B 3B 4B 5B 6B 7B 8B 9B 10B
2A
Station 2 SOL.b
3A
SOL.a
4A
Station 3 SOL.b
5A
SOL.a
6A 7A
(−)
6B
4B (−) (+)
8A
SOL.a
8B
5A (−) (+)
9A 10A COM
Station 5 SOL.b
9B 10B
5B (−) (+)
SOL.a
6A (−) (+)
Station 6 SOL.b
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM
6B (−) (+)
SOL.a
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A COM
1B 2B 3B 4B 5B 6B 7B 8B 9B 10B
7A (−) (+)
Station 7 SOL.b
1B 2B 3B 4B 5B 6B 7B 8B 9B 10B
7B (−) (+)
SOL.a
8A (−) (+)
If alignment is not specified, the Station 8 SOL.b
8B (−) (+)
internal wiring will be double wiring SOL.a
9A (−) (+)
(connected to SOL. a and SOL. b) Station 9 SOL.b
regardless of number of stations, 9B (−) (+)
SOL.a
valve types, and option types. 10A (−) (+)
Station 10 SOL.b
10B (−) (+)
77
78
Plug-in Connector Connecting Base
Type 10
Side Ported Lead Wire
SY3000/5000/7000 Series
Type 11
Bottom Ported
RoHS
How to Order Manifolds
…
9 cores
16 16 stations 04 4 stations
w Type 02 2 stations Specified layout∗2 02 2 stations Specified layout∗2
r Lead wire length
…
…
(Up to 32 solenoids (Up to 8 solenoids
10 Side ported
24 24 stations available) 08 8 stations available)
11 Bottom ported∗1 1 0.6 m
∗1 The SY5000 manifold base is 2 1.5 m (L2)
used for the bottom-ported 3 3m Symbol Stations Note
SY3000. When ordering, refer 02 2 stations
to the “Plug-in Manifold Mixed Double wiring∗1
…
(Up to 16 solenoids
16 16 stations available)
∗1 Double wiring: 2-position single, double, 3-position, and 4-position
valves can be used on all manifold stations.
How to Order Manifold Assembly Use of a 2-position single solenoid will result in an unused control
signal. If this is not desired, order with a specified layout.
∗2 Specified layout: Indicate the wiring specifications on the manifold
Example (SS5Y3-10L11-) specification sheet. (Note that 2-position double, 3-position, and
2-position double (24 VDC) 4-position valves cannot be used where single wiring has been
2-position single (24 VDC)
SY3200-5U1 (1 set) specified.)
3-position closed ∗ This also includes the number of the blanking plate assembly.
SY3100-5U1 (3 sets)
centre (24 VDC)
SY3300-5U1 (1 set)
y P, E port entry
U U side (2 to 10 stations)
D D side (2 to 10 stations)
B Both sides (2 to 24 stations)
Straight
C4 Ø4 — — N7 Ø 1/4"
Straight
C6 Ø6 N9 Ø 5/16" —
C8 Ø8 — N11 Ø 3/8" — — —
C10 Ø 10 — — — CM∗1 Straight port, mixed sizes
C12 Ø 12 — — — LN3 Ø 5/32" — — — —
Upward
CM∗1 Straight port, mixed sizes LN7 Ø 1/4" — — —
L4 Ø4 — — — LN9 Ø 5/16" — — — —
L6 Ø6 — — LN11 Ø 3/8" — — — —
Upward
Elbow∗2
L8 Ø8 — — — BN3 Ø 5/32" — — — —
Downward
B4 Ø4 — — — BN11 Ø 3/8" — — — —
Downward
P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).
80
SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted
w Type of actuation
1
2-position
Single u Coil type E: F:
2 Double — Standard
Push-turn Slide locking
3 Closed centre T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit type lever
5 Pressure centre if the valve is to be continuously energised for type
A∗1 N.C./N.C. long periods of time.
B∗1
4-position
N.O./N.O. ∗ Be careful of the energising time when the
dual 3-port power saving circuit is selected. Refer to page
C∗1 N.C./N.O.
316 for details. ∗ Refer to page 36 for the safety slide locking
∗1 Only the rubber seal type is available for the manual override.
4-position dual 3-port valve.
i Rated voltage
5 24 VDC
!1 Type of mounting screw
e Seal type 6 12 VDC
— Round head combination screw
0 Rubber seal B Hexagon socket head cap screw
1 Metal seal K Round head combination screw (Drop prevention type)
o Light/surge voltage suppressor H Hexagon socket head cap screw (Drop prevention type)
and common specification ∗ For “K” and “H,” the valve body cover has a
r Pilot type Symbol With light
Surge voltage Common
suppressor specification
drop prevention construction to stop the
mounting screws from falling out when the
— Internal pilot valve is removed for maintenance, etc.
— — —
R External pilot ∗ When ordering a valve individually, the
R — Non-polar base gasket is not included.
U Since the base gasket is attached to the
S — Positive manifold, please order the base gasket
t Back pressure check valve Z
common separately if it is needed for maintenance.
(Built-in valve type) NS — Negative Refer to page 222 for base gasket and
common mounting screw part numbers.
— None NZ
∗ “B” and “H” cannot be selected for the
H Built-in ∗ For the non-polar type, be careful of surge individual SUP/EXH spacer assembly,
∗ Only the rubber seal type is available. A voltage intrusion. interface regulator, or double check spacer
manifold installed type is available if a back Refer to page 317 for details. assembly with residual pressure release
pressure check valve with a metal seal is ∗ Only “Z” and “NZ” types are available with a valve.
required. Refer to page 236 for ordering power saving circuit.
examples. However, it is not recommended
to use the built-in valve type and the manifold
installed type at the same time because it will
reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.
Protective class
class # (Mark: )
81
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
C2
1 U
SS5Y3-10L 2 - Stations D - C3, N1
C4, N3 (D)
3 B C6, N7
One-touch fitting
[4(A), 2(B) port]
One-touch fitting
Applicable tube O.D.: Ø 2
[1(P), 3/5(E) port] (Station 1)---(Station n) : Ø 3.2, Ø 1/8"
Applicable tube O.D.: Ø 8, Ø 5/16" : Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
1 P 1 P
13.6
10.6
63.1
56.6
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2
21.6
4 A4 A4 A4 A4 A
18
11.8
54.8 15.5 P = 10.5 (17.8)
D side U side
Manual override∗1
(L5) L1
DIN rail holding screw
(
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail Light/surge : Grey (For metal seal)
2(B) port side : Yellow
voltage suppressor
5.5
8
B A B A B A B A B A
92.6
14 A 14 A 14 A 14 A 14 A
35
83
67.8
60.5
40.9
4.6
12 B 12 B 12 B 12 B 12 B
17
4.6
1.7
N7: 7.4 )
3.6
(4.9)
(C6:
4 x M4 mounting hole
18 (Fitting for the type with P/E
ports on the U and/or D sides)
43 L2 1.5
∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10L1-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 112 122.5 133 143.5 154 164.5 175 185.5 196 206.5 217 227.5 238 248.5 259 269.5 280 290.5 301 311.5 322 332.5 343
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 135.5 148 160.5 173 185.5 198 210.5 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 335.5 335.5 348 360.5 373
L4 125 137.5 150 162.5 175 187.5 200 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 325 325 337.5 350 362.5
L5 12 13 14 15 16 17 18 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12 13 14 15
82
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
1 U C4, N3
SS5Y5-10L 2 - Stations D - C6, N7 (D)
3 B C8, N9
One-touch fitting
[4(A), 2(B) port]
(Station 1)----------- (Station n) Applicable tube O.D.: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
One-touch fitting : Ø 8, Ø 5/16"
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 10, Ø 3/8"
14.1
1 P 1 P
73.2
2 B2 B2 B2 B2 B
56.6
8.7
33.4
3/5 E 3/5 E
29.1
4 A4 A4 A4 A4 A
12.4
7.5
11.8
56.5 18 P = 16 (20.5)
D side U side
Manual override∗1
(L5) L1
DIN rail holding screw (Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail Light/surge : Grey (For metal seal)
voltage suppressor 2(B) port side : Yellow
5.5
8
BA BA BA BA BA
14 A 14 A 14 A 14 A 14 A
35
97.5
113.4
64.4
81.2
61.7
5.5
12 B 12 B 12 B 12 B 12 B
24.2
10.9
4.7
(5.9)
(8.3)
4 x M5 mounting hole
18
(Fitting for the type with P/E
42.5 L2 1.5
18
ports on the U and/or D sides)
(Lead wire length)
0.6 m, 1.5 m, 3 m
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3
∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10L1-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 129 145 161 177 193 209 225 241 257 273 289 305 321 337 353 369 385 401 417 433 449 465 481
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320 336 352 368 384 400 416 432
L3 160.5 173 185.5 210.5 223 235.5 260.5 273 285.5 298 323 335.5 348 360.5 385.5 398 410.5 435.5 448 460.5 473 498 510.5
L4 150 162.5 175 200 212.5 225 250 262.5 275 287.5 312.5 325 337.5 350 375 387.5 400 425 437.5 450 462.5 487.5 500
L5 16 14 12.5 17 15 13.5 18 16 14.5 12.5 17 15.5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15
83
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
C6, N7
1 U
SS5Y7-10L 2 - Stations D - C8, N9
C10, N11 (D)
3 B C12
(Station 1) (Station n)
One-touch fitting
[1(P), 3/5(E) port]
2
Applicable tube O.D.: Ø 12, Ø 1/2"
82.7
1 P 1 P
2 B2 B2 B2 B2 B
56.6
11.1
3/5 E 3/5 E
8.7
35.2
31.6
4 A4 A4 A4 A4 A
14.2
(10)
(21.7)
mounting)
61.5 20.5 P = 19
(14.3)
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
: Ø 12
D side U side
Manual override ∗1
(L5) L1
DIN rail holding screw (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
(Light/surge voltage suppressor) : Grey (For metal seal)
2(B) port side: Yellow
B A B A B A B A B A
(35)
14 A 14 A 14 A 14 A 14 A
64.4
128.8
115
(5.5)
96.7
(77.1)
12 B 12 B 12 B 12 B 12 B
5.5
39.6
(17.9)
∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10L1-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 143.2 162.2 181.2 200.2 219.2 238.2 257.2 276.2 295.2 314.2 333.2 352.2 371.2 390.2 409.2 428.2 447.2 466.2 485.2 504.2 523.2 542.2 561.2
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 173 185.5 210.5 235.5 248 273 285.5 310.5 323 348 360.5 385.5 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5
L4 162.5 175 200 225 237.5 262.5 275 300 312.5 337.5 350 375 387.5 412.5 425 450 462.5 487.5 500 525 537.5 562.5 575
L5 15 11.5 14.5 17.5 14.5 17.5 14 17 14 17 13.5 16.5 13.5 16.5 13 16 13 16 12.5 15.5 12.5 15.5 12
84
Plug-in Connector Connecting Base
Lead Wire
SY3000/5000/7000 Series ®
RoHS
How to Order Manifolds
SS5Y 3 12 L1 1 05 U
Refer to pages 182 to 184
for the dimensions of
Type 12/Top-ported type.
q w e r t y u i
q Series r Valve stations
3 SY3000 (L1) (L3)
5 SY5000 Symbol Stations Note Symbol Stations Note
7 SY7000 02 2 stations 02 2 stations
Double wiring∗1 Double wiring∗1
…
…
w Number of cores 16 16 stations 04 4 stations
(Lead wire) e Lead wire length 02 2 stations Specified layout∗2 02 2 stations Specified layout∗2
…
…
L1 34 cores 1 0.6 m (Up to 32 solenoids (Up to 8 solenoids
L2 17 cores 2 1.5 m 24 24 stations available) 08 8 stations available)
L3 9 cores 3 3m (L2)
Symbol Stations Note
t P, E port entry 02 2 stations
U∗1 Double wiring∗1
…
U side (2 to 10 stations)
D∗1 D side (2 to 10 stations) 08 8 stations
B Both sides (2 to 24 stations) 02 2 stations Specified layout∗2
…
1
2
3
u P, E port size (One-touch fittings)
e
D sid Symbol SY3000 SY5000 SY7000
Manifold base
(5 stations) — Ø8 Ø 10 Ø 12
SS5Y3-12L11-05D
N Ø 5/16" Ø 3/8" Ø 1/2"
∗ For N, sizes are in inches.
SS5Y3-12L11-05D ··· 1 set (Type 12 5-station manifold base part no.)
∗SY3130-5U1-C6 ······· 3 sets (2-position single part no.)
∗SY3230-5U1-C6 ······· 1 set (2-position double part no.) i Mounting
∗SY3330-5U1-C6 ······· 1 set (3-position closed centre part no.) — Direct mounting
The asterisk denotes the symbol for the assembly. D DIN rail mounting (With DIN rail)
Prefix it to the part numbers of the valve, etc. D0 DIN rail mounting (Without DIN rail)
• For the valve arrangement, the valve closest to the D side is considered the 1st station. D3 For 3 stations Specify a length longer
…
• Under the manifold part number, state the valves to be mounted in order starting than that of the standard
with the 1st station as shown in the figure above. If the arrangement becomes too D24 For 24 stations rail.
complicated, specify the details on a manifold specification sheet. ∗ Refer to page 319 for the fixation of DIN rail mounting type manifold.
85
Plug-in Connector Connecting Base SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported
Protective class
class # (Mark: )
86
SY3000/5000/7000 Series
Specified Layout
A mixture of single and double wiring can be specified on the
manifold specification. The maximum number of stations is
determined according to the number of solenoids. The total number
of solenoids should be 32 or less. 1 solenoid is required for the
2-position single, and 2 solenoids for the 2-position double,
3-position, and 4-position.
87
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Positive Negative
common common
88
Plug-in Connector Connecting Base
Type 10
Side Ported Circular Connector
SY3000/5000/7000 Series
Type 11
Bottom Ported
RoHS
How to Order Manifolds
SS5Y3-10M-05D-C6
total length of specified stations.
SS5Y3-10M-05D-C6 ··· 1 set (Type 10 5-station manifold base part no.) 24 For 24 stations
∗SY3100-5U1 ··············· 3 sets (2-position single part no.)
∗SY3200-5U1 ··············· 1 set (2-position double part no.)
∗SY3300-5U1 ··············· 1 set (3-position closed centre part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
• For the valve arrangement, the valve closest to the D side is considered the 1st station.
• Under the manifold part number, state the valves to be mounted in order
starting with the 1st station as shown in the figure above. If the arrangement
becomes too complicated, specify the details on a manifold specification sheet.
∗ When mixing top-ported configurations, select from those listed on page 96.
In such cases, use caution as there is also output on the A and B ports on the base side.
Specify on the manifold specification sheet if plugs are required for the A and B ports on
the base side.
89
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Straight
C4 Ø4 — — N7 Ø 1/4"
Straight
C6 Ø6 N9 Ø 5/16" —
C8 Ø8 — N11 Ø 3/8" — — —
C10 Ø 10 — — — CM∗1 Straight port, mixed sizes
C12 Ø 12 — — — LN3 Ø 5/32" — — — —
Upward
CM∗1 Straight port, mixed sizes LN7 Ø 1/4" — — —
L4 Ø4 — — — LN9 Ø 5/16" — — — —
L6 Ø6 — — LN11 Ø 3/8" — — — —
Upward
Elbow∗2
L8 Ø8 — — — BN3 Ø 5/32" — — — —
Downward
B4 Ø4 — — — BN11 Ø 3/8" — — — —
Downward
P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).
Protective class
class # (Mark: )
90
SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted
w Type of actuation
1
2-position
Single u Coil type E: F:
2 Double — Standard Push-turn Slide locking
3 Closed centre T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit lever
5 Pressure centre type if the valve is to be continuously type
A∗1 N.C./N.C. energised for long periods of time.
B∗1
4-position
N.O./N.O. ∗ Be careful of the energising time when the
dual 3-port power saving circuit is selected. Refer to
C∗1 N.C./N.O.
page 316 for details. ∗ Refer to page 36 for the safety slide locking
∗1 Only the rubber seal type is available for the manual override.
4-position dual 3-port valve.
i Rated voltage
5 24 VDC
6 12 VDC
!1 Type of mounting screw
e Seal type — Round head combination screw
0 Rubber seal B Hexagon socket head cap screw
1 Metal seal
o Light/surge voltage suppressor K Round head combination screw (Drop prevention type)
and common specification H Hexagon socket head cap screw (Drop prevention type)
Surge voltage Common ∗ For “K” and “H,” the valve body cover has a
r Pilot type Symbol With light
suppressor specification drop prevention construction to stop the
mounting screws from falling out when the
— Internal pilot — — —
valve is removed for maintenance, etc.
R External pilot R — Non-polar ∗ When ordering a valve individually, the
U base gasket is not included.
S — Positive Since the base gasket is attached to the
Z common manifold, please order the base gasket
t Back pressure check valve NS — Negative separately if it is needed for maintenance.
(Built-in valve type) common Refer to page 222 for base gasket and
NZ
mounting screw part numbers.
— None ∗ For the non-polar type, be careful of surge ∗ “B” and “H” cannot be selected for the
H Built-in voltage intrusion. individual SUP/EXH spacer assembly,
∗ Only the rubber seal type is available. A Refer to page 317 for details. interface regulator, or double check spacer
manifold installed type is available if a back ∗ Only “Z” and “NZ” types are available with a assembly with residual pressure release
pressure check valve with a metal seal is power saving circuit. valve.
required. Refer to page 236 for ordering
examples. However, it is not recommended
to use the built-in valve type and the manifold
installed type at the same time because it will
reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.
Protective class
class # (Mark: )
91
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
C2
U
SS5Y3-10M- Stations D - C3, N1
C4, N3 (D)
B C6, N7
One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] (Station 1)---(Station n) Applicable tube O.D.: Ø 2
Applicable tube O.D.: Ø 8, Ø 5/16" : Ø 3.2, Ø 1/8"
: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
1 P 1 P
63.1
13.6
10.6
56.6
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2
21.6
4 A4 A4 A4 A4 A
18
mounting)
7.5
(Pitch)
11.8
made by CONINVERS GmbH 54.8 15.5 P = 10.5 (17.8)
D side U side
(L5) L1 Manual override ∗1
8
B A B A B A B A B A
92.6
14 A 14 A 14 A 14 A 14 A
35
83
67.8
60.5
40.9
4.6
12 B 12 B 12 B 12 B 12 B
21.9
4.6
1.7
)
C6: 3.6
N7: 7.4
(4.9)
4 x M4 mounting hole
18
(Fitting for the type with P/E ports on the U and/or D sides)
(
18
43 L2 1.5
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3
∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10M-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 112 122.5 133 143.5 154 164.5 175 185.5 196 206.5 217 227.5 238 248.5 259 269.5 280 290.5 301 311.5 322 332.5 343
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 135.5 148 160.5 173 185.5 198 210.5 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 335.5 335.5 348 360.5 373
L4 125 137.5 150 162.5 175 187.5 200 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 325 325 337.5 350 362.5
L5 12 13 14 15 16 17 18 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12 13 14 15
92
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C4, N3
SS5Y5-10M- Stations D - C6, N7 (D)
B C8, N9
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 4, Ø 5/32"
(Station 1)----------- (Station n) : Ø 6, Ø 1/4"
One-touch fitting : Ø 8, Ø 5/16"
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 10, Ø 3/8"
14.1
1 P 1 P
73.2
2 B2 B2 B2 B2 B
56.6
12.4
8.7
3/5 E 3/5 E
29.1
33.4
4 A4 A4 A4 A4 A
11.8
56.5 18 P = 16 (20.5)
D side U side
Manual override∗1
(L5) L1
DIN rail holding screw
(Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
: Grey (For metal seal)
DIN rail Light/surge voltage suppressor
2(B) port side : Yellow
5.5
8
BA BA BA BA BA
14 A 14 A 14 A 14 A 14 A
35
97.5
113.4
64.4
81.2
61.7
5.5
12 B 12 B 12 B 12 B 12 B
24.2
10.9
4.7
18
(5.9)
(8.3)
18 4 x M5 mounting hole
∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10M-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.
93
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
C6, N7
U
SS5Y7-10M- Stations D - C8, N9
C10, N11 (D)
B C12
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 6, Ø 1/4"
(Station 1) (Station n)
: Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
: Ø 12
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 12, Ø 1/2"
2
82.7
1 P 1 P
2 B2 B2 B2 B2 B
56.6
11.1
3/5 E 3/5 E
8.7
35.2
31.6
4 A4 A4 A4 A4 A
14.2
(10)
(21.7)
mounting)
61.5 20.5 P = 19
(14.3)
Circular connector (26 pins)
Made by CONINVERS GmbH
D side U side
Manual override∗1
(L5) L1
DIN rail holding screw (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
: Grey (For metal seal)
(Light/surge voltage suppressor) 2(B) port side: Yellow
B A B A B A B A B A
(35)
14 A 14 A 14 A 14 A 14 A
64.4
128.8
115
(5.5)
96.7
(77.1)
5.5
12 B 12 B 12 B 12 B 12 B
39.6
8.8
3.9
(6)
18
(9.3)
(17.9)
∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10M-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 143.2 162.2 181.2 200.2 219.2 238.2 257.2 276.2 295.2 314.2 333.2 352.2 371.2 390.2 409.2 428.2 447.2 466.2 485.2 504.2 523.2 542.2 561.2
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 173 185.5 210.5 235.5 248 273 285.5 310.5 323 348 360.5 385.5 398 423 435.5 460.5 473 498 510.5 535.5 548 573 585.5
L4 162.5 175 200 225 237.5 262.5 275 300 312.5 337.5 350 375 387.5 412.5 425 450 462.5 487.5 500 525 537.5 562.5 575
L5 15 11.5 14.5 17.5 14.5 17.5 14 17 14 17 13.5 16.5 13.5 16.5 13 16 13 16 12.5 15.5 12.5 15.5 12
94
Plug-in Connector Connecting Base
Circular Connector
Type 12
Top Ported
SY3000/5000/7000 Series ®
RoHS
How to Order Manifolds
SS5Y 3 12M 05 U
Refer to pages 182 to 184
for the dimensions of
Type 12/Top-ported type.
q w e r t y
q Series w Valve stations e P, E port entry
3 SY3000 Symbol Stations Note U∗1 U side (2 to 10 stations)
5 SY5000 02 2 stations D∗1 D side (2 to 10 stations)
Double wiring∗1
…
Example (SS5Y3-12M-)
2-position single (24 VDC)
2-position double (24 VDC)
SY3230-5U1-C6 (1 set)
t P, E port size (One-touch fittings)
SY3130-5U1-C6 (3 sets) Symbol SY3000 SY5000 SY7000
3-position closed
centre (24 VDC)
— Ø8 Ø 10 Ø 12
SY3330-5U1-C6 (1 set)
N Ø 5/16" Ø 3/8" Ø 1/2"
∗ For N, sizes are in inches.
Us
ide
y Mounting
ns
atio — Direct mounting
St
3 DIN rail mounting
2 D (With DIN rail)
1
ide
Ds
DIN rail mounting
D0 (Without DIN rail)
Manifold base (5 stations)
D3 For 3 stations Specify a length longer
SS5Y3-12M-05D
…
95
Plug-in Connector Connecting Base SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported
Protective class
class # (Mark: )
96
SY3000/5000/7000 Series
L
Station 2 SOL.b
4 (−) (+) 9 Grey Black
SOL.a
5 (−) (+) 10 White Black
Station 3 SOL.b
6 (−) (+)
60
11 White Red
SOL.a
7 (−) (+) 12 Yellow Red
Station 4 SOL.b
8 (−) (+) 13 Orange Red
SOL.a Plug
9 (−) (+) 14 Yellow Black
Station 5 SOL.b
10 (−) (+) 15 Pink Black
SOL.a
11 (−) (+) 16 Blue White
Station 6 SOL.b
12 (−) (+) 17 Purple None
SOL.a
13 (−) (+) 18 Grey None
Station 7 SOL.b
14 (−) (+) 19 Orange Black
SOL.a Ø 30
15 (−) (+) 20 Red White
Station 8 SOL.b
16 (−) (+) 21 Brown White
SOL.a 1 15
17 (−) (+) 2 14 Terminal no. 22 Pink Red
Station 9 SOL.b 17
16
24
18 (−) (+) 3 13 23 Grey Red
SOL.a 25
19 (−) (+) 18 23
4 12 24 Black White
Station 10 SOL.b
20 (−) (+) 19 26 22 25 White None
SOL.a 5
20 21
11
21 (−) (+) 26 White None
Station 11 SOL.b 6 10
22 (−) (+) 7 9
M27 female
SOL.a 8 thread
23 (−) (+) Electrical characteristics
Station 12 SOL.b
24 (−) (+) Item Property
COM.
25 (+) (−) Conductor
COM. 65 or
26 (+) (−) resistance
less
Ω/km, 20 °C
Positive Negative
Voltage limit
common common 1000
V, 1 minute, AC
Circular connector cable assembly
Insulation
Cable Assembly part no. 5 or
resistance
length (L) 26 pins more
MΩ/km, 20 °C
∗ When using a valve with no polarity, either positive common or 1.5 m AXT100-MC26-015
negative common can be used. ∗ The minimum bending
3m AXT100-MC26-030 radius of the circular
5m AXT100-MC26-050 connector cable is 20
∗ Cannot be used for movable wiring mm.
∗ Lengths other than the above is also
Specified Layout available. Please contact SMC for details.
A mixture of single and double wiring can be specified on the manifold
specification sheet. The maximum number of stations is determined
according to the number of solenoids. The total number of solenoids
should be 24 or less. 1 solenoid is required for the 2-position single,
and 2 solenoids for the 2-position double, 3-position, and 4-position.
97
98
Plug-in Connector Connecting Base
Type 10
Side Ported EX500 Gateway Decentralised System 2 (128 Points)
Type 11
Bottom Ported
SY3000/5000/7000 Series ®
RoHS
How to Order Manifolds
…
7 SY7000 32 outputs∗1∗4, 2 to 16 stations (24
A3N stations∗3), Negative common∗2 16 16 stations
∗ For mixed mounting, refer to page 185 and
later. ∗1 16 outputs can be set by switching the built-in 02 2 stations
Specified layout∗2
…
setting switch. (Up to 32 solenoids available)
∗2 Ensure a match with the common specification 24 24 stations
w Type of the valve. ∗1 Double wiring: 2-position single, double,
10 Side ported ∗3 ( ): Maximum number of stations for mixed 3-position, and 4-position valves can be
11 Bottom ported∗1 single and double wiring used on all manifold stations.
∗1 The SY5000 manifold base is used for the ∗4 When using the SI unit with 32 outputs, use Use of a 2-position single solenoid will
bottom-ported SY3000. When ordering, the GW unit compatible with the EX500 result in an unused control signal.
refer to the “Plug-in Manifold Mixed Gateway Decentralised System 2 (128 points). If this is not desired, order with a specified
Mounting Type” (from page 185). layout.
∗ When mixing top-ported configurations, ∗2 Specified layout: Indicate the wiring
select from those listed on +page 114. specifications on the manifold specification
In such cases, use caution as there is also sheet. (Note that 2-position double,
output on the A and B ports on the base side. 3-position, and 4-position valves cannot be
Specify on the manifold specification sheet if used where single wiring has been
plugs are required for the A and B ports on specified.)
the base side. ∗ When the product without the SI unit (S0) is
selected, note the maximum number of
solenoids of the SI unit that will be mounted.
If the layout is specified, indicate it on the
How to Order Manifold Assembly manifold specification sheet.
∗ This also includes the number of the blanking
plate assembly.
Example
Manifold base 2-position double
t P, E port entry
U U side (2 to 10 stations)
D D side (2 to 10 stations)
B Both sides (2 to 24 stations)
silencer type.
ta
S
99
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Straight
C4 Ø4 — — N7 Ø 1/4"
Straight
C6 Ø6 N9 Ø 5/16" —
C8 Ø8 — N11 Ø 3/8" — — —
C10 Ø 10 — — — CM∗1 Mixed sizes
C12 Ø 12 — — — LN3 Ø 5/32" — — — —
Upward
CM∗1 Mixed sizes LN7 Ø 1/4" — — —
L4 Ø4 — — — LN9 Ø 5/16" — — — —
L6 Ø6 — — LN11 Ø 3/8" — — — —
Upward
Elbow∗2
L8 Ø8 — — — BN3 Ø 5/32" — — — —
Downward
B4 Ø4 — — — BN11 Ø 3/8" — — — —
Downward
B6 Ø6 — —
LM∗1 Mixed sizes — —
B8 Ø8 — — —
B10 Ø 10 — — — —
P, E port∗3 Ø 5/16" Ø 3/8" Ø 1/2" Ø 3/8" Ø 1/2"
B12 Ø 12 — — — —
P, E port∗3 Ø8 Ø 10 Ø 12 Ø 10 Ø 12
Protective class
class # (Mark: )
100
SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted
w Type of actuation
1 Single
2
2-position
Double u Coil type E
Push-turn
F
Slide locking
3 Closed centre — Standard locking type
4 3-position Exhaust centre
T
With power saving circuit lever
5 Pressure centre (Continuous duty type)∗1∗2 type
A∗1 N.C./N.C. ∗1 Be sure to select the power saving circuit
4-position dual
B∗1 3-port valve
N.O./N.O. type if the valve is to be continuously
C∗1 N.C./N.O. energised for long periods of time.
∗2 Be careful of the energising time when the ∗ Refer to page 36 for the safety slide locking
∗1 Select the rubber seal type for the 4-position manual override.
dual 3-port valve. power saving circuit is selected. For details,
refer to page 316.
Protective class
class # (Mark: )
101
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C2
SS5Y3-10SA3N- Stations DB -C3, N1
C4, N3 (D)
C6, N7
One-touch fitting
[1(P), 3/5(E) port] One-touch fitting
Applicable tube O.D.: Ø 8, Ø 5/16"
[4(A), 2(B) port]
(Station 1) (Station n)
M12 Applicable tube O.D.: Ø 2
: Ø 3.2, Ø 1/8"
: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
OUT
1 P 1 P
76.7
67.2
10.6
13.6
63.1
IN
56.6
46.2
3/5 E 3/5 E
(11.8)
2 B2 B2 B2 B2 B
40.2
25.6
21.6
4 A4 A4 A4 A4 A
18
(7.5)
46.5 15.5 P = 10.5 (17.8)
D side U side
(8)
B A B A B A B A B A
(35)
92.6
14 A 14 A 14 A 14 A 14 A
83
80.2
60.5
(40.9)
12 B 12 B 12 B 12 B 12 B
21.2
4.6
4.6
1.7
)
C6: 3.6
N7: 7.4
(4.9)
4 x M4 Mounting hole
SI Unit
(
L2 1.5 (Fitting for the type with P/E ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)
∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10SA3N-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.
L: Dimensions n: Stations
L n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 103.7 114.2 124.7 135.2 145.7 156.2 166.7 177.2 187.7 198.2 208.7 219.2 229.7 240.2 250.7
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210
L3 135.5 148 148 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5
L4 125 137.5 137.5 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275
L5 16 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5
L n 17 18 19 20 21 22 23 24
L1 261.2 271.7 282.2 292.7 303.2 313.7 324.2 334.7
L2 220.5 231 241.5 252 262.5 273 283.5 294
L3 285.5 298 310.5 323 335.5 348 348 360.5
L4 275 287.5 300 312.5 325 337.5 337.5 350
L5 12 13 14 15 16 17 12 13
102
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C4, N3
SS5Y5-10SA3N- Stations DB -C6, N7 (D)
C8, N9
One-touch fitting
[1(P), 3/5(E) port] One-touch fitting
Applicable tube O.D.: Ø 10, Ø 3/8" (Station 1) (Station n) [4(A), 2(B) port]
Applicable tube O.D.: Ø 4, Ø 5/32"
M12
: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
OUT
14.1
76.7
1 P 1 P
73.2
67.2
IN 2 B2 B2 B2 B2 B
56.6
46.2
(11.8)
3/5 3/5
33.4
E E
29.1
25.6
4 A4 A4 A4 A4 A
8.7
12.4
11.3 (Pitch)
(7.5)
M12 48.2 18 P = 16 (20.5)
D side U side
Light/surge voltage suppressor Manual override∗1
(L5) L1 4(A) port side: Blue (for rubber seal)
: Grey (for metal seal)
2(B) port side: Yellow
(5.5)
(8)
B A B A B A B A B A
(35)
14 A 14 A 14 A 14 A 14 A
97.5
113.4
101
81.2
(61.7)
5.5
12 B 12 B 12 B 12 B 12 B
10.9
0.4
4.7
(5.9)
(8.3)
SI Unit
34.2 L2 1.5
(5.3) (L4) 4 x M5 Mounting hole
(DIN rail mounting hole pitch: 12.5) (Fitting for the type with P/E ports on the U and/or D sides)
(L3)
∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10SA3N-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.
L: Dimensions n: Stations
L n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304
L3 148 160.5 185.5 198 210.5 235.5 248 260.5 273 298 310.5 323 348 360.5 373
L4 137.5 150 175 187.5 200 225 237.5 250 262.5 287.5 300 312.5 337.5 350 362.5
L5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14
L n 17 18 19 20 21 22 23 24
L1 360.7 376.7 392.7 408.7 424.7 440.7 456.7 472.7
L2 320 336 352 368 384 400 416 432
L3 385.5 410.5 423 435.5 448 473 485.5 498
L4 375 400 412.5 425 437.5 462.5 475 487.5
L5 12.5 17 15 13.5 11.5 16 14.5 12.5
103
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C6, N7
SS5Y7-10SA3N- Stations DB -C8, N9
C10, N11 (D)
C12
2
OUT
11.1
82.7
1 P 1 P
76.7
S
2 B2 B2 B2 B2 B
67.2
IN
56.6
46.2
(14.3)
3/5 E 3/5 E
35.2
31.6
4 A4 A4 A4 A4 A
25.6
8.7
14.2
11.3 (Pitch)
(10)
M12 53.2 20.5 P = 19 21.7
D side U side
(8)
B A B A B A B A B A
(35)
14 A 14 A 14 A 14 A 14 A
101.4
128.8
115
96.7
(5.5)
(77.1)
5.5
12 B 12 B 12 B 12 B 12 B
15
8.8
3.9
(6)
(N13: 20.4)
SI Unit
(9.3)
(17.9)
∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10SA3N-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.
L: Dimensions n: Stations
L n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 134.9 153.9 172.9 191.9 210.9 229.9 248.9 267.9 286.9 305.9 324.9 343.9 362.9 381.9 400.9
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360
L3 160.5 185.5 198 223 235.5 260.5 273 298 310.5 335.5 348 373 398 410.5 435.5
L4 150 175 187.5 212.5 225 250 262.5 287.5 300 325 337.5 362.5 387.5 400 425
L5 13 16 12.5 15.5 12.5 15.5 12 15 12 15 11.5 14.5 17.5 14.5 17.5
L n 17 18 19 20 21 22 23 24
L1 419.9 438.9 457.9 476.9 495.9 514.9 533.9 552.9
L2 379 398 417 436 455 474 493 512
L3 448 473 485.5 510.5 523 548 560.5 585.5
L4 437.5 462.5 475 500 512.5 537.5 550 575
L5 14 17 14 17 13.5 16.5 13.5 16.5
104
Plug-in Connector Connecting Base
Type 10
Side Ported EX500 Gateway Decentralised System (64 Points)
SY3000/5000/7000 Series
Type 11
Bottom Ported
RoHS
How to Order Manifolds
…
7 SY7000 16 outputs,
∗ For mixed mounting, refer to page 185 and A2 Positive common∗1, 08 8 stations
later. 2 to 8 stations (16 stations)∗2 02 2 stations
Specified layout∗2
…
16 outputs, (Up to 16 solenoids available)
Negative common∗1, 16 16 stations
w Type A2N
2 to 8 stations (16 stations)∗2 ∗1 Double wiring: 2-position single, double,
10 Side ported ∗1 Ensure a match with the common 3-position, and 4-position valves can be
11 Bottom ported∗1 specification of the valve to be used. used on all manifold stations.
∗1 The SY5000 manifold base is used for the ∗2 ( ): Maximum number of stations for mixed Use of a 2-position single solenoid will
bottom-ported SY3000. When ordering, single and double wiring result in an unused control signal. If this is
refer to the “Plug-in Manifold Mixed not desired, order with a specified layout.
Mounting Type” (from page 185). ∗2 Specified layout: Indicate the wiring
∗ When mixing top-ported configurations, specifications on the manifold specification
select from those listed on page 114. sheet. (Note that 2-position double,
In such cases, use caution as there is also 3-position, and 4-position valves cannot be
output on the A and B ports on the base side. used where single wiring has been
Specify on the manifold specification sheet if specified.)
plugs are required for the A and B ports on ∗ When the product without the SI unit (S0) is
the base side. selected, note the maximum number of
solenoids of the SI unit that will be mounted.
If the layout is specified, indicate it on the
manifold specification sheet.
How to Order Manifold Assembly ∗ This also includes the number of the blanking
plate assembly.
Example (SS5Y3-10SA2-)
2-position double (24 VDC) t P, E port entry
2-position single (24 VDC) SY3200-5U1 (1 set) U U side (2 to 10 stations)
SY3100-5U1 (3 sets) D D side (2 to 10 stations)
3-position closed
centre (24 VDC) B Both sides (2 to 16 stations)
SY3300-5U1 (1 set)
105
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Straight
C4 Ø4 — — N7 Ø 1/4"
Straight
C6 Ø6 N9 Ø 5/16" —
C8 Ø8 — N11 Ø 3/8" — — —
C10 Ø 10 — — — CM∗1 Mixed sizes
C12 Ø 12 — — — LN3 Ø 5/32" — — — —
Upward
CM∗1 Mixed sizes LN7 Ø 1/4" — — —
L4 Ø4 — — — LN9 Ø 5/16" — — — —
L6 Ø6 — — LN11 Ø 3/8" — — — —
Upward
Elbow∗2
L8 Ø8 — — — BN3 Ø 5/32" — — — —
Downward
B4 Ø4 — — — BN11 Ø 3/8" — — — —
Downward
B6 Ø6 — —
LM∗1 Mixed sizes — —
B8 Ø8 — — —
B10 Ø 10 — — — — P, E port∗3
Ø 5/16" Ø 3/8" Ø 1/2" Ø 3/8" Ø 1/2"
B12 Ø 12 — — — — (One-touch fittings)
P, E port∗3
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).
∗3 The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
Protective class
class # (Mark: )
106
SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted
w Type of actuation
1
2-position
Single u Coil type E: F:
2 Double — Standard Push-turn Slide locking
3 Closed centre T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit lever
5 Pressure centre type if the valve is to be continuously type
A∗1 N.C./N.C. energised for long periods of time.
B∗1
4-position
N.O./N.O. ∗ Be careful of the energising time when the
dual 3-port power saving circuit is selected. Refer to page
C∗1 N.C./N.O.
316 for details. ∗ Refer to page 36 for the safety slide locking
∗1 Only the rubber seal type is available for the manual override.
4-position dual 3-port valve.
i Rated voltage
5
!1 Type of mounting screw
24 VDC
e Seal type — Round head combination screw
0 Rubber seal
B Hexagon socket head cap screw
1 Metal seal o Light/surge voltage suppressor K Round head combination screw (Drop prevention type)
and common specification H Hexagon socket head cap screw (Drop prevention type)
Symbol With light
Surge voltage Common ∗ For “K” and “H,” the valve body cover has a
r Pilot type suppressor specification drop prevention construction to stop the
mounting screws from falling out when the
— Internal pilot R —
Non-polar valve is removed for maintenance, etc.
R External pilot U
∗ When ordering a valve individually, the
S — Positive
base gasket is not included.
Z common Since the base gasket is attached to the
NS — Negative manifold, please order the base gasket
t Back pressure check valve NZ common separately if it is needed for maintenance.
(Built-in valve type) ∗ For the non-polar type, be careful of surge Refer to page 222 for base gasket and
voltage intrusion. mounting screw part numbers.
— None
Refer to page 317 for details. ∗ “B” and “H” cannot be selected for the
H Built-in individual SUP/EXH spacer assembly,
∗ Only “Z” and “NZ” are available with a power
∗ Only the rubber seal type is available. A saving circuit. Select “R,” “U,” “S,” or “Z” for interface regulator, or double check spacer
manifold installed type is available if a back the valve when the SI unit specification is A2 assembly with residual pressure release
pressure check valve with a metal seal is (positive common). Select “R,” “U,” “NS,” or valve.
required. Refer to page 236 for ordering “NZ” for the valve when the SI unit
examples. However, it is not recommended specification is A2N (negative common).
to use the built-in valve type and the manifold
installed type at the same time because it will
reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.
Protective class
class # (Mark: )
107
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
C2
U
SS5Y3-10SA2- Stations D - C3, N1
C4, N3 (D)
B C6, N7
One-touch fitting
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 8, Ø 5/16" [4(A), 2(B) port]
(Station 1)---(Station n) Applicable tube O.D.: Ø 2
M12 : Ø 3.2, Ø 1/8"
8-pin socket : Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
0
1 P 1 P
63.1
10.6
13.6
56.6
1
60
43.2
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2
22.2
21.6
4 A4 A4 A4 A4 A
18
(7.5)
mounting)
17.5 (Pitch)
(11.8)
8-pin plug
46.3 15.5 P = 10.5 (17.8)
D side U side
Manual override∗1
(8)
B A B A B A B A B A
(35)
92.6
14 A 14 A 14 A 14 A 14 A
83
67.8
60.5
(40.9)
12 B 12 B 12 B 12 B 12 B
4.6
4.6
1.7
N7: 7.4 )
(4.9)
3.6
12.1
4 x M4 mounting hole
(C6:
(Fitting for the type with P/E ports on the U and/or D sides)
34.5 L2 1.5
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)
∗1 Refer to page 177 or dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10SA2-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 103.5 114 124.5 135 145.5 156 166.5 177 187.5 198 208.5 219 229.5 240 250.5
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210
L3 135.5 148 148 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5
L4 125 137.5 137.5 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275
L5 16 17 12 13 14 15 16 17 18 12.5 13.5 14.5 15.5 16.5 17.5
108
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C4, N3
SS5Y5-10SA2- Stations D - C6, N7 (D)
B C8, N9
One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: Ø 4, Ø 5/32"
Applicable tube O.D.: Ø 10, Ø 3/8" (Station 1)----------- (Station n) : Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
M12
8-pin socket
0
14.1
1 P 1 P
73.2
2 B2 B2 B2 B2 B
56.6
60
1
43.2
33.4
3/5 E 3/5 E
29.1
22.2
4 A4 A4 A4 A4 A
12.4
8.7
(11.8)
M12 (Pitch)
48 18 P = 16 (20.5)
8-pin plug
D side U side
Manual override∗1
(L5) L1
DIN rail holding screw (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
(Light/surge voltage suppressor) : Grey (For metal seal)
SI unit 2(B) port side : Yellow
DIN rail
(5.5)
(8)
BA BA BA BA BA
(35)
14 A 14 A 14 A 14 A 14 A
97.5
113.4
79.9
81.2
(61.7)
5.5
12 B 12 B 12 B 12 B 12 B
10.9
8.7
4.7
(5.9)
(8.3)
4 x M5 mounting hole
34 L2 1.5
(Fitting for the type with P/E
(5.3) (L4) ports on the U and/or D sides)
(DIN rail mounting hole pitch: 12.5)
(L3)
∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10SA2-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 120.5 136.5 152.5 168.5 184.5 200.5 216.5 232.5 248.5 264.5 280.5 296.5 312.5 328.5 344.5
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304
L3 148 160.5 185.5 198 210.5 235.5 248 260.5 273 298 310.5 323 348 360.5 373
L4 137.5 150 175 187.5 200 225 237.5 250 262.5 287.5 300 312.5 337.5 350 362.5
L5 14 12 16.5 15 13 17.5 16 14 12.5 17 15 13.5 18 16 14.5
109
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
C6, N7
U
SS5Y7-10SA2- Stations D - C8, N9
C10, N11 (D)
B C12
One-touch fitting
[4(A), 2(B) port]
One-touch fitting
Applicable tube O.D.: Ø 6, Ø 1/4"
[1(P), 3/5(E) port] (Station 1) (Station n) : Ø 8, Ø 5/16"
Applicable tube O.D.: Ø 12, Ø 1/2" : Ø 10, Ø 3/8"
M12 : Ø 12
8-pin socket
2
0
82.7
1 P 1 P
2 B2 B2 B2 B2 B
56.6
1
60
43.2
11.1
3/5 E 3/5 E
35.2
8.7
31.6
4 A4 A4 A4 A4 A
22.2
14.2
(14.3)
(Pitch)
mounting)
M12
8-pin plug 53 20.5 P = 19
D side U side
(L5) L1 Manual override∗1
B A B A B A B A B A
(35)
14 A 14 A 14 A 14 A 14 A
128.8
115
79.9
(5.5)
96.7
(77.1)
12 B 12 B 12 B 12 B 12 B
5.5
24.1
8.8
3.9
(6)
(9.3)
(17.9)
∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10SA2-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 134.7 153.7 172.7 191.7 210.7 229.7 248.7 267.7 286.7 305.7 324.7 343.7 362.7 381.7 400.7
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360
L3 160.5 185.5 198 223 235.5 260.5 273 298 310.5 335.5 348 373 398 410.5 435.5
L4 150 175 187.5 212.5 225 250 262.5 287.5 300 325 337.5 362.5 387.5 400 425
L5 13 16 12.5 15.5 12.5 15.5 12 15 12 15 11.5 14.5 17.5 14.5 17.5
110
Plug-in Connector Connecting Base
EX500 Gateway Decentralised System 2 (128 Points)
SY3000/5000/7000 Series ®
RoHS
How to Order Manifolds
E port entry.
(Up to 32 solenoids available)
24 24 stations
w SI unit (Number of outputs, Output polarity,
Max. number of valve stations)
∗1 Double wiring: 2-position single, double,
3-position, and 4-position valves can be used on
t SUP/EXH block assembly
0 Without SI unit all manifold stations. Use of a 2-position single — Internal pilot
32 outputs∗1∗4, 2 to 16 stations (24 solenoid will result in an unused control signal. If S∗1 Internal pilot, Built-in silencer∗2
A3N stations∗3), Negative common∗2 this is not desired, order with a specified layout. R External pilot
∗1 16 outputs can be set by switching the ∗2 Specified layout: Indicate the wiring ∗1 For type “S”, SUP/EXH block assembly
built-in setting switch. specifications on the manifold specification with a built-in silencer, choose U or D for P,
∗2 Ensure a match with the common sheet. (Note that 2-position double, E port entry. 3/5(E) port is plugged. The
specification of the valve. 3-position, and 4-position valves cannot be silencer exhaust port is located on the
∗3 ( ): Maximum number of stations for used where single wiring has been specified.) opposite side of the P and E port entry.
mixed single and double wiring ∗ When the product without the SI unit (S0) is (Example: When the P and E port entry is
∗4 When using the SI unit with 32 outputs, selected, note the maximum number of on the D side, the silencer exhaust port is
use the GW unit compatible with the solenoids of the SI unit that will be mounted. on the U side.)
EX500 Gateway Decentralised System 2 If the layout is specified, indicate it on the ∗2 When the built-in silencer type is used,
(128 points). manifold specification sheet. keep the exhaust port from coming into
∗ This also includes the number of the blanking direct contact with water or other liquids.
plate assembly.
u Mounting
— Direct mounting
D With DIN bracket, DIN rail with standard length
D0 With DIN bracket, without DIN rail
D3∗1 With DIN bracket, DIN rail for 3 stations
de
…
si
U
Then, refer to L3 of the dimensions for the DIN rail length and
si
D
order separately. Refer to page 227 for the DIN rail part number.
Manifold base ∗ Refer to page 319 for the fixation of DIN rail mounting type
manifold.
SS5Y3-12SA3N-05D ········1 set (Manifold base part number)
∗ SY3230-5U1-C6 ·············5 sets (2-position double part number)
∗ A separate GW unit and communication cable are required.
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc. For details on the EX500 Gateway Type Serial Transmission
System, refer to the Web Catalogue and the Operation
• For the valve arrangement, the valve closest to the D side is considered the 1st station. Manual. For the part numbers of the SI units to be mounted,
• Under the manifold base part number, state the valves to be mounted in order refer to page 208. Please download the Operation Manual via
starting with the 1 st station as shown in the figure above. If the arrangement the SMC website, https://www.smc.eu
becomes too complicated, specify the details on a manifold specification sheet.
111
Plug-in Connector Connecting Base SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported
Protective class
class # (Mark: )
112
Plug-in Connector Connecting Base
EX500 Gateway Decentralised System (64 Points)
Type 12
Top Ported
SY3000/5000/7000 Series ®
RoHS
How to Order Manifolds
SS5Y 3 12S A2 05 U
Refer to pages 182 to 184
for the dimensions of
Type 12/Top-ported type.
q w e r t y u
q Series r P, E port entry e Valve stations
3 SY3000 U∗1 U side (2 to 10 stations) Symbol Stations Note
5 SY5000 D∗1 D side (2 to 10 stations) 02 2 stations
Double wiring∗1
…
7 SY7000 B Both sides (2 to 16 stations)
∗ For mixed mounting, refer to page 185 and ∗1 tFor type “S”, SUP/EXH block assembly 08 8 stations
later. with a built-in silencer, choose U or D for P, 02 2 stations
E port entry. Specified layout∗2
…
(Up to 16 solenoids available)
16 16 stations
w SI unit (Number of outputs, Output polarity, ∗1 Double wiring: 2-position single, double,
Max. number of valve stations) t SUP/EXH block assembly 3-position, and 4-position valves can be
0 Without SI unit — Internal pilot used on all manifold stations.
16 outputs, S Internal pilot, Built-in silencer Use of a 2-position single solenoid will
A2 Positive common∗1, R External pilot result in an unused control signal. If this is
not desired, order with a specified layout.
2 to 8 stations (16 stations)∗2 ∗ The P and E ports are only available on the ∗2 Specified layout: Indicate the wiring
16 outputs, U and D sides for the built-in silencer type. specifications on the manifold specification
A2N Negative common∗1, 3/5(E) port is plugged. The silencer exhaust sheet. (Note that 2-position double,
2 to 8 stations (16 stations)∗2 port is located on the opposite side of the P 3-position, and 4-position valves cannot be
and E port entry. (Example: When the P and used where single wiring has been
∗1 Ensure a match with the common E port entry is on the D side, the silencer
specification of the valve to be used. specified.)
exhaust port is on the U side.) ∗ When the product without the SI unit (S0) is
∗2 ( ): Maximum number of stations for mixed ∗ When the built-in silencer type is used, keep
single and double wiring selected, note the maximum number of
the exhaust port from coming into direct solenoids of the SI unit that will be mounted.
contact with water or other liquids. If the layout is specified, indicate it on the
manifold specification sheet.
How to Order Manifold Assembly ∗ This also includes the number of the blanking
plate assembly.
Example (SS5Y3-12SA2-)
2-position double (24 VDC)
y P, E port size (One-touch fittings)
SY3230-5U1-C6 (1 set) Symbol SY3000 SY5000 SY7000
2-position single (24 VDC)
SY3130-5U1-C6 (3 sets) 3-position closed — Ø8 Ø 10 Ø 12
centre (24 VDC) N Ø 5/16" Ø 3/8" Ø 1/2"
SY3330-5U1-C6 (1 set)
∗ For N, sizes are in inches.
u Mounting
— Direct mounting
ide D With DIN bracket, DIN rail with standard length
Us D0 With DIN bracket, without DIN rail
s
n
D3∗1
tio
3
2 D16∗1 With DIN bracket, DIN rail for 16 stations
1
ide
Manifold base Ds ∗1 Specify a longer rail than the length of valve stations.
(5 stations) ∗ If the DIN rail must be mounted without an SI unit, select
SS5Y3-12SA2-05D “D0.” Then, refer to L3 of the dimensions for the DIN rail
length and order separately. Refer to page 227 for the DIN
rail part number.
SS5Y3-12SA2-05D ··· 1 set (Type 12 5-station manifold base part no.)
∗ Refer to page 319 for the fixation of DIN rail mounting type
∗SY3130-5U1-C6 ········ 3 sets (2-position single part no.)
manifold.
∗SY3230-5U1-C6 ········ 1 set (2-position double part no.)
∗SY3330-5U1-C6 ········ 1 set (3-position closed centre part no.)
The asterisk denotes the symbol for the assembly.
∗ A separate GW unit and communication cable are required.
Prefix it to the part numbers of the valve, etc. For details on the EX500 Gateway Type Serial Transmission
• For the valve arrangement, the valve closest to the D side is considered the 1st station. System, refer to the Web Catalogue and the Operation
• Under the manifold part number, state the valves to be mounted in order Manual. For the part numbers of the SI units to be mounted,
starting with the 1st station as shown in the figure above. If the arrangement refer to page 2 0 9 . Please download the Operation Manual
becomes too complicated, specify the details on a manifold specification sheet. via the SMC website, https://www.smc.eu
113
Plug-in Connector Connecting Base SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported
Protective class
class # (Mark: )
114
Plug-in Connector Connecting Base
Type 10
Side Ported EX600
SY3000/5000/7000 Series
Type 11
Bottom Ported
RoHS
How to Order Manifolds
…
7 SY7000 — — —
Direct
9 9 stations AA
mounting
∗ When not selecting an SI unit, the symbol will BA —
w Type be “—.” D — —
∗ SI unit is not included in I/O unit stations. DIN rail
10 Side ported A
∗ When I/O unit is selected, it is shipped mounting
11 Bottom ported∗1 B —
separately, and assembled by users. Refer to
∗1 The SY5000 manifold base is used for the the attached operation manual for mounting. ∗ Enter the number of stations inside when it
bottom-ported SY3000. When ordering, is larger than the number of valve stations.
refer to the “Plug-in Manifold Mixed (Refer to “DIN Rail Option” below.)
Mounting Type” (from page 185). ∗ Only direct mounting is available for the type
y Valve stations 11 bottom-ported type.
e SI unit Symbol Stations Note
∗ Refer to page 319 for the fixation of DIN rail
mounting type manifold.
0 Without SI unit 02 2 stations DIN Rail Option
Q DeviceNet™ (Version A) Double wiring∗1
…
r SI unit output polarity, end plate type u P, E port entry, SUP/EXH block assembly
M12 M12 power supply connector Internal Internal pilot, External
7/8 inch P, E port entry
power supply IN/OUT, A-coded pilot Built-in silencer pilot
power supply
SI unit output polarity connector Pin Pin U side (2 to 10 stations) U C G
connector
B-coded
(EX600-ED3) arrangement 1 arrangement 2 D side (2 to 10 stations) D E H
(EX600-ED2) (EX600-ED4) (EX600-ED5) Both sides (2 to 24 stations) B F J
Without SI unit — ∗ 3/5(E) port is plugged for the built-in silencer type.
SI unit positive common 2 3 6 8 ∗ When the built-in silencer type is used, keep the exhaust port from
SI unit negative common 4 5 7 9 coming into direct contact with water or other liquids.
∗ Ensure a match with the common specification of the valve to be used.
∗ When not selecting an SI unit, the symbol will be “—.”
Refer to the page on the right for i.
115
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Straight
C4 Ø4 — — N7 Ø 1/4"
Straight
C6 Ø6 N9 Ø 5/16" —
C8 Ø8 — N11 Ø 3/8" — — —
C10 Ø 10 — — — CM∗1 Straight port, mixed sizes
C12 Ø 12 — — — LN3 Ø 5/32" — — — —
Upward
CM∗1 Straight port, mixed sizes LN7 Ø 1/4" — — —
L4 Ø4 — — — LN9 Ø 5/16" — — — —
L6 Ø6 — — LN11 Ø 3/8" — — — —
Upward
Elbow∗2
L8 Ø8 — — — BN3 Ø 5/32" — — — —
Downward
B4 Ø4 — — — BN11 Ø 3/8" — — — —
Downward
P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).
Example (SS5Y3-10S6-) SS5Y3-10S6Q72-05B-C6 ··· 1 set (Type 10 5-station manifold base part no.)
∗SY3100-5U1 ······················· 3 sets (2-position single part no.)
∗SY3200-5U1 ······················· 2 sets (2-position double part no.)
Digital input unit Digital output unit 2-position single ∗EX600-DXPD ····················· 1 set I/O unit part number (Station 1)
EX600-DXPD EX600-DYPB SY3100-5U1 (3 sets) ∗EX600-DYPB ····················· 1 set I/O unit part number (Station 2)
End plate∗1 SI unit∗1 2-position double The asterisk denotes the symbol for the assembly.
EX600-ED4 EX600-SDN1A SY3200-5U1 (2 sets) Prefix it to the part numbers of the valve, etc.
0 1 • For the valve arrangement, the valve closest to the D side is considered the
1st station.
2 3
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A • Under the manifold part number, state the valves to be mounted, then the I/O units in
D side
PWR
OUT U side order starting with the 1st station as shown in the figure above. If the arrangement
0 1
4 5 becomes too complicated, specify the details on a manifold specification sheet.
2 3 12 B 12 B 12 B 12 B 12 B
PCI
BUS BUS
IN OUT
∗1 Do not enter the SI unit part number and the end plate part number
8 7
together.
∗ When mixing top-ported configurations, select from those listed on page
1 2 3 4 5 Valve stations 126.
1 2 I/O unit stations
In such cases, use caution as there is also output on the A and B ports on
the base side.
Specify on the manifold specification sheet if plugs are required for the A
and B ports on the base side.
Protective class
class # (Mark: )
116
SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted
w Type of actuation
1
2-position
Single u Coil type E: F:
2 Double — Standard Push-turn Slide locking
3 Closed centre T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit lever
5 Pressure centre type if the valve is to be continuously type
A∗1 N.C./N.C. energised for long periods of time.
B∗1
4-position
N.O./N.O. ∗ Be careful of the energising time when the
dual 3-port power saving circuit is selected. Refer to
C∗1 N.C./N.O.
page 316 for details. ∗ Refer to page 36 for the safety slide locking
∗1 Only the rubber seal type is available for the manual override.
4-position dual 3-port valve.
i Rated voltage
5 24 VDC
Protective class
class # (Mark: )
117
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
2
4 U C2 One-touch fitting
SS5Y3-10S6 - Stations D - C3, N1 ( )
C4, N3 D
6
7 [4(A), 2(B) port]
8 B C6, N7
Applicable tube O.D.: Ø 2
9
: Ø 3.2, Ø 1/8"
(Station 1)---(Station n)
11.5
: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
8
1 P 1 P
63.1
56.6
13.2
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2
21.6
4 A4 A4 A4 A4 A
18
10.6
13.6
(For DIN rail
mounting)
7.5
One-touch fitting
(Pitch)
11.8
D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override∗1
(L5) L1
DIN rail
holding screw 5.5 L6 L2 ( Push-turn locking slotted type:
Press, then rotate it. )
(For DIN 47 8 DIN rail holding screw 1.5 4(A) port side
Communication connector
rail mounting) (For DIN rail mounting) : Blue (For rubber seal)
2 x M4 mounting hole : Grey (For metal seal)
Power Light/surge 2(B) port side : Yellow 85.1
connector Marker groove
voltage suppressor
0 1
5.5
B A B A B A B A B A
2 3
92.6
14 A 14 A 14 A 14 A 14 A
35
83
106
PWR
90
OUT
60.5
0 1
4 5
40.9
2 3
4.6
8 7
8
4.6
1.7
)
C6: 3.6
N7: 7.4
(4.9)
FE 86.6
terminal 5.4 4 x M4 mounting hole
(
L1 = 10.5 x n1 + 135.5 + 47 x n2 ∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
L2 = 10.5 x n1 + 42 ∗ These figures show the “SS5Y3-10S6Q22-05D-C6.”
L4 = L3 – 10.5 ∗ Refer to page 182 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 47 x n2 + 82
n1: Valve stations
n2: I/O unit stations
L3: DIN Rail Overall Length
Valve
stations
I/O (n1)
unit 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423
1 235.5 248 248 260.5 273 285.5 298 310.5 323 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5 448 448 460.5
2 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 410.5 423 435.5 448 460.5 473 485.5 485.5 498 510.5
3 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5 448 448 460.5 473 485.5 498 510.5 510.5 523 535.5 548 560.5
4 373 385.5 398 410.5 410.5 423 435.5 448 460.5 473 473 485.5 498 510.5 523 535.5 548 548 560.5 573 585.5 598 610.5
5 423 435.5 448 448 460.5 473 485.5 498 510.5 510.5 523 535.5 548 560.5 573 573 585.5 598 610.5 623 635.5 635.5 648
6 473 473 485.5 498 510.5 523 535.5 535.5 548 560.5 573 585.5 598 610.5 610.5 623 635.5 648 660.5 673 673 685.5 698
7 510.5 523 535.5 548 560.5 573 573 585.5 598 610.5 623 635.5 635.5 648 660.5 673 685.5 698 698 710.5 723 735.5 748
8 560.5 573 585.5 598 598 610.5 623 635.5 648 660.5 673 673 685.5 698 710.5 723 735.5 735.5 748 760.5 773 785.5 798
9 610.5 623 635.5 635.5 648 660.5 673 685.5 698 698 710.5 723 735.5 748 760.5 760.5 773 785.5 798 810.5 823 835.5 835.5
118
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
Dimensions: SY3000 Series Connector Connecting Base EX600 (7/8 Inch Connector)
U C2
SS5Y3-10S6 35 - Stations D - C3, N1 ( )
C4, N3 D One-touch fitting
B C6, N7
[4(A), 2(B) port]
Applicable tube O.D.: Ø 2
: Ø 3.2, Ø 1/8"
11.5
: Ø 4, Ø 5/32"
(Station 1)---(Station n)
: Ø 6, Ø 1/4"
8
1 P 1 P
63.1
56.6
13.2
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2
21.6
4 A4 A4 A4 A4 A
18
10.6
13.6
(For DIN rail
7.5
mounting)
D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5)
(L5) L1 Manual override∗1
DIN rail
holding screw
5.5 L6 L2 ( Push-turn locking slotted type:
Press, then rotate it. )
Communication connector 47 8 DIN rail holding screw 1.5 4(A) port side
(For DIN (For DIN rail mounting) : Blue (For rubber seal)
rail mounting) 2 x M4 mounting hole
Light/surge : Grey (For metal seal)
Marker groove 2(B) port side : Yellow
voltage suppressor
0 1
5.5
B A B A B A B A B A
2 3
92.6
14 A 14 A 14 A 14 A 14 A
35
83
106
90
60.5
0 1
4 5
40.9
PWR
2 3
4.6
8 7
8
4.6
1.7
)
C6: 3.6
N7: 7.4
(4.9)
FE 36.7
terminal 5.4 4 x M4 mounting hole
(
∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
L1 = 10.5 x n1 + 152 + 47 x n2 ∗ These figures show the “SS5Y3-10S6Q32-05D-C6.”
L2 = 10.5 x n1 + 42 ∗ Refer to page 182 for dimensions of A or B port top-ported type.
L4 = L3 – 10.5
L5 = (L3 – L1)/2
L6 = 47 x n2 + 82
n1: Valve stations
n2: I/O unit stations
L3: DIN Rail Overall Length
Valve
stations
I/O (n1)
unit 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 198 210.5 223 235.5 248 260.5 260.5 273 285.5 298 310.5 323 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5
1 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 360.5 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5
2 298 310.5 323 323 335.5 348 360.5 373 385.5 385.5 398 410.5 423 435.5 448 448 460.5 473 485.5 498 510.5 523 523
3 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548 548 560.5 573
4 385.5 398 410.5 423 435.5 448 448 460.5 473 485.5 498 510.5 510.5 523 535.5 548 560.5 573 585.5 585.5 598 610.5 623
5 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548 548 560.5 573 585.5 598 610.5 610.5 623 635.5 648 660.5 673
6 485.5 498 510.5 510.5 523 535.5 548 560.5 573 573 585.5 598 610.5 623 635.5 648 648 660.5 673 685.5 698 710.5 710.5
7 535.5 548 548 560.5 573 585.5 598 610.5 610.5 623 635.5 648 660.5 673 673 685.5 698 710.5 723 735.5 735.5 748 760.5
8 573 585.5 598 610.5 623 635.5 635.5 648 660.5 673 685.5 698 710.5 710.5 723 735.5 748 760.5 773 773 785.5 798 810.5
9 623 635.5 648 660.5 673 673 685.5 698 710.5 723 735.5 735.5 748 760.5 773 785.5 798 798 810.5 823 835.5 848 860.5
119
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
2
4 One-touch fitting
U C4, N3
SS5Y5-10S6 - Stations D - C6, N7 (D) 6
7
[4(A), 2(B) port]
8 B C8, N9 Applicable tube O.D.: Ø 4, Ø 5/32"
9 : Ø 6, Ø 1/4"
(Station 1)----------(Station n) : Ø 8, Ø 5/16"
11.5
1 P 1 P
73.2
2 B2 B2 B2 B2 B
56.6
13.2
33.4
3/5 E 3/5 E
29.1
4 A4 A4 A4 A4 A
12.4
14.1
8.7
7.5
One-touch fitting
(For DIN rail
mounting)
D side U side
L3
5.3 L4 Manual override∗1
(DIN rail mounting hole pitch: 12.5)
DIN rail
(L5) L1 ( Push-turn locking slotted type:
Press, then rotate it. )
L6 L2 4(A) port side
holding screw 5.5 : Blue (For rubber seal)
(For DIN Communication connector DIN rail holding screw
47 8 1.5 : Grey (For metal seal)
rail mounting) (For DIN rail mounting) 2(B) port side : Yellow
2 x M4 mounting hole
Power
connector Marker groove Light/surge voltage suppressor 85.1
DIN rail
0 1
BA BA BA BA BA 5.5
2 3
35
14 A 14 A 14 A 14 A 14 A
97.5
113.4
90
PWR
OUT
0 1
4 5
2 3
BUS
PCI
BUS 8
IN OUT
5.5
7.4
12 B 12 B 12 B 12 B 12 B
8 7
61.7
81.2
15.4
10.9
4.7
(5.9)
(8.3)
L1 = 16 x n1 + 141.5 + 47 x n2 ∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
L2 = 16 x n1 + 48 ∗ These figures show the “SS5Y5-10S6Q22-05D-C8.”
L4 = L3 – 10.5 ∗ Refer to page 183 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 47 x n2 + 81.5
n1: Valve stations
n2: I/O unit stations
L3: DIN Rail Overall Length
Valve
stations
I/O (n1)
unit 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
stations
(n2)
0 198 223 235.5 248 273 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 560.5
1 248 260.5 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598
2 298 310.5 323 348 360.5 373 398 410.5 423 435.5 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 623 635.5 648
3 348 360.5 373 398 410.5 423 435.5 460.5 473 485.5 498 523 535.5 548 573 585.5 598 610.5 635.5 648 660.5 685.5 698
4 385.5 410.5 423 435.5 460.5 473 485.5 498 523 535.5 548 573 585.5 598 610.5 635.5 648 660.5 673 698 710.5 723 748
5 435.5 448 473 485.5 498 523 535.5 548 560.5 585.5 598 610.5 635.5 648 660.5 673 698 710.5 723 748 760.5 773 785.5
6 485.5 498 523 535.5 548 560.5 585.5 598 610.5 623 648 660.5 673 698 710.5 723 735.5 760.5 773 785.5 810.5 823 835.5
7 535.5 548 560.5 585.5 598 610.5 623 648 660.5 673 698 710.5 723 735.5 760.5 773 785.5 798 823 835.5 848 873 885.5
8 573 598 610.5 623 648 660.5 673 685.5 710.5 723 735.5 760.5 773 785.5 798 823 835.5 848 873 885.5 898 910.5 935.5
9 623 648 660.5 673 685.5 710.5 723 735.5 748 773 785.5 798 823 835.5 848 860.5 885.5 898 910.5 935.5 948 960.5 973
120
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
Dimensions: SY5000 Series Connector Connecting Base EX600 (7/8 Inch Connector)
U C4, N3
SS5Y5-10S6 35 - Stations D - C6, N7 (D) One-touch fitting
B C8, N9 [4(A), 2(B) port]
Applicable tube O.D.: Ø 4, Ø 5/32"
(Station 1)----------(Station n) : Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
11.5
1 P 1 P
73.2
2 B2 B2 B2 B2 B
56.6
13.2
33.4
3/5 E 3/5 E
29.1
4 A4 A4 A4 A4 A
8.7
12.4
14.1
(For DIN rail
mounting)
7.5
L3
D side U side
5.3 L4
(DIN rail mounting hole pitch: 12.5)
(L5) L1 Manual override∗1
DIN rail
holding screw
5.5 L6 L2 (Push-turn locking slotted type:
Press, then rotate it. )
16.5 2 x M4 mounting hole 47 8 DIN rail holding screw 1.5 4(A) port side
(For DIN : Blue (For rubber seal)
Communication connector (For DIN rail mounting)
rail mounting) : Grey (For metal seal)
Light/surge voltage suppressor
Marker groove 2(B) port side : Yellow
DIN rail
0 1
2 3
BA BA BA BA BA 5.5
35
14 A 14 A 14 A 14 A 14 A
90
97.5
113.4
0 1
PWR
4 5
81.2
2 3
60.4
PCI 8
61.7
BUS BUS
IN OUT
5.5
7.4
12 B 12 B 12 B 12 B 12 B
8 7 10.9
15.4
4.7
36.7
(8.3)
(5.9)
2 One-touch fitting
4 U C6, N7
SS5Y7-10S6 - Stations D - C8, N9 ( ) 6 [4(A), 2(B) port]
C10, N11 D 7
B C12 (Station 1) (Station n) Applicable tube O.D.: Ø 6, Ø 1/4"
8 : Ø 8, Ø 5/16"
9 : Ø 10, Ø 3/8"
: Ø 12
11.5
2
8
82.7
1 P 1 P
2 B2 B2 B2 B2 B
(56.6)
56.6
13.2
3/5 E 3/5 E
35.2
31.6
4 A4 A4 A4 A4 A
11.1
14.2
8.7
(For DIN rail
(Pitch)
(10)
mounting)
(14.3)
D side U side
(L3)
(5.3) (L4)
DIN rail holding screw (DIN rail mounting hole pitch: 12.5)
Manual override∗1
(L5) (For DIN rail mounting) L1
5.5 L6 L2 ( Push-turn locking slotted
type: Press, then rotate it. )
2 x M4 mounting hole 47 8 DIN rail holding screw 1.5 4(A) port side
Power Communication connector (For DIN rail mounting) : Blue (For rubber seal)
connector : Grey (For metal seal)
Marker groove Valve plate Light/surge voltage suppressor 2(B) port side: Yellow 85.1
(DIN rail)
0 1
(5.5)
B A B A B A B A B A
2 3
14 A 14 A 14 A 14 A 14 A
(35)
90
PWR
128.8
OUT
115
0 1
4 5
2 3
96.7
PCI
FE BUS
IN
BUS
OUT
(8)
(77.1)
terminal
8 7
12 B 12 B 12 B 12 B 12 B
5.5
30.8
22.8
5.4
8.8
3.9
(6)
SI unit
(9.3)
86.6
(17.9)
L1 = 19 x n1 + 149.7 + 47 x n2 ∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
L2 = 19 x n1 + 56 ∗ These figures show the “SS5Y7-10S6Q22-05D-C10.”
L3 = DIN rail dimension ∗ Refer to page 184 for dimensions of A or B port top-ported type.
L4 = L3 – 10.5
L5 = (L3 – L1)/2
L6 = 47 x n2 + 81.7
n1: Valve stations
n2: I/O unit stations
Dimensions: SY7000 Series Connector Connecting Base EX600 (7/8 Inch Connector)
U C6, N7
SS5Y7-10S6 35 - Stations D - C8, N9 ( )
C10, N11 D One-touch fitting
B C12
[4(A), 2(B) port]
(Station 1) (Station n) Applicable tube O.D.: Ø 6, Ø 1/4"
One-touch fitting : Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
[1(P), 3/5(E) port] : Ø 12
Applicable tube O.D.: Ø 12, Ø 1/2"
11.5
2
8
82.7
1 P 1 P
2 B2 B2 B2 B2 B
(56.6)
56.6
13.2
8.7
3/5 E 3/5 E
35.2
31.6
4 A4 A4 A4 A4 A
11.1
14.2
(For DIN rail
(Pitch)
(10)
mounting)
(14.3)
25 20.5 P = 19 (21.7)
0 1
(5.5)
B A B A B A B A B A
2 3
(35)
14 A 14 A 14 A 14 A 14 A
90
128.8
115
0 1
4 5
PWR
2 3
96.7
PCI
FE BUS
IN
BUS
OUT (8)
(77.1)
terminal
8 7
75.8
5.5
12 B 12 B 12 B 12 B 12 B
31
22.8
5.4
8.8
3.9
End plate
(6)
(9.3)
36.7
(17.9)
Input connector Valve plate (Fitting for the type with P/E
ports on the U and/or D sides)
Output connector SI unit
Digital output unit Connector for
handheld terminal
L1 = 19 x n1 + 166.2 + 47 x n2
L2 = 19 x n1 + 56
L4 = L3 – 10.5 ∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
L5 = (L3 – L1)/2 ∗ These figures show the “SS5Y7-10S6Q32-05D-C10.”
L6 = 47 x n2 + 81.7 ∗ Refer to page 184 for dimensions of A or B port top-ported type.
n1: Valve stations
n2: I/O unit stations
Top Ported
RoHS
How to Order Manifolds
SS5Y 3 12S6 Q 2 05 U
Refer to pages 182 to 184
for the dimensions of
Type 12/Top-ported type. q w e r t y u i
q Series e SI unit output polarity, end plate type t Valve stations
3 SY3000 M12 7/8 inch
M12 power supply connector Symbol Stations Note
power supply IN/OUT, A-coded
5 SY5000 SI unit output polarity connector power supply
Pin Pin
02 2 stations
connector
Double wiring∗1
···
B-coded
···
7 SY7000
(EX600-ED2) (EX600-ED3) arrangement 1 arrangement 2
(EX600-ED4) (EX600-ED5)
16 16 stations
Without SI unit —
02 2 stations
SI unit positive common 2 3 6 8 Specified layout∗2
···
···
SI unit negative common 4 5 7 9 (Up to 32 solenoids available)
24 24 stations
∗ When not selecting an SI unit, the symbol will be “—.”
∗1 Double wiring: 2-position single, double,
w SI unit ∗ Ensure a match with the common specification of the valve to be used.
3-position, and 4-position valves can be
used on all manifold stations.
Q
0 Without SI unit
DeviceNet™ (Version A)
r I/O unit stations Use of a 2-position single solenoid will result
— None in an unused control signal. If this is not
N PROFIBUS DP (Version A) desired, order with a specified layout.
V CC-Link 1 1 station
∗2 Specified layout: Indicate the wiring
···
···
D side
PWR
OUT U side N Ø 5/16" Ø 3/8" Ø 1/2"
0 1
4 5
2 3
PCI
1P
2B 2B 2B 2B 2B
1P ∗ For N, sizes are in inches.
BUS BUS
i Mounting
IN OUT
8 7
···
125
Plug-in Connector Connecting Base SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported
···
02 2 stations C6 Ø6
Double wiring∗1 C8 Ø8 —
···
···
16 16 stations C10 Ø 10 — — —
02 2 stations Specified layout∗2 C12 Ø 12 — — —
CM∗2 Straight port, mixed sizes
···
···
(Available up to 32
solenoids) L4 Ø4 — — —
24 24 stations
Upward
L6 Ø6 — —
∗1: Double wiring: 2-position single, double, 3-position L8 Ø8 — — —
and 4-position valves can be used on all manifold L10 Ø 10 — — — —
stations. Use of a 2-position single solenoid will L12 Ø 12 — — — —
result in an unused control signal. If this is not ∗1
B4 Ø4 — — —
Elbow
Downward
N7 Ø 1/4"
i SUP/EXH block assembly N9 Ø 5/16" —
N11 Ø 3/8" — — —
— Internal pilot
CM∗2 Straight port, mixed sizes
S Internal pilot, Built-in silencer
LN3 Ø 5/32" — — — —
Downward Upward
R External pilot
LN7 Ø 1/4" — — —
∗: 3/5(E) port is plugged for the built-in silencer type. LN9 Ø 5/16" — — — —
∗: When the built-in silencer type is used, keep LN11 1 Ø 3/8" — — — —
∗
the exhaust port from coming in direct contact BN3 Ø 5/32" — — — —
Elbow
Example (SS5Y3-10SAAN-)
2-position double (24 VDC) 3-position closed centre SS5Y3-10SAANY2-05D-C6 ···1 set (Type 10 5-station manifold base part no.)
SY3200-5U1 (1 set) (24 VDC) ∗SY3100-5U1 ···························3 sets (2-position single part no.)
SY3300-5U1 (1 set) ∗SY3200-5U1 ···························1 set (2-position double part no.)
2-position single (24 VDC) ∗SY3300-5U1 ···························1 set (3-position closed centre part no.)
SY3100-5U1 (3 sets) ∗EX245-DX1 ····························1set I/O module part no.
Digital input module ∗EX245-DY1 ····························1set I/O module part no.
EX245-DX1 The asterisk denotes the symbol for assembly.
Digital output module Prefix it to the part numbers of the valve etc.
EX245-DY1
ide
• The valve arrangement is numbered as the 1st station from the D side.
Us
• The I/O module station arrangement is numbered starting from the SI unit side.
ns
io
at
St
2
3 • Under the manifold part number, state the valves to be mounted, then the I/O
1
ide module in order from the 1st station as shown in the figure above. If the
Ds
arrangement becomes complicated, specify on a manifold specification sheet.
SI Unit∗1 ∗1: Do not enter the SI Unit part number and the end plate part number together.
1 ∗: When mixing top ported configurations, select from page 126. In this case,
EX245-SPN1A
use caution as there is also output on the A and B port on base side.
2 End plate∗1 Specify on a manifold specification sheet if plugs are required on the A
s
Sta
tion EX245-EA2-3 and B port on base side.
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted
manual override)
(Slide locking
1 P 1 P
68.8
63.1
61.5
40.2
3/5 E 2 B2 B2 B2 B2 B 3/5 E
21.6
4 A4 A4 A4 A4 A
18
(Pitch)
10.6
13.6
One-touch fitting 18.3 15.5 P = 10.5
[1(P), 3/5(E) port] (17.8)
Applicable tube O.D Ø 8
Ø 5/16"
X0 0 2 X1 X0 0 2 X1
1 3 1 3
B A B A B A B A
X2 4 6 X3 X2 4 6 X3
92.6
14 A 14 A 14 A 14 A
83
83
120
60.5
5 7 5 7
X4 8 10 X5
4.6
12 B 12 B 12 B 12 B
9 11
14.5
X6 12 14 X7
4.6
1.7
C6: 3.6 (4.9)
13 15
4 x M4 Mounting hole
17.5
)
7.5
N7: 7.4
<SS5Y3-10SACN>
3/5 E 2 B2
4 A4
BA
14 A
12
27.7
L3 = 54 x n2 + 113.6
∗ n1 is the valve stations.
Dimensions Formula/L1 = 10.5 x n1 + 167.1 L2 = 10.5 x n1 + 42 ∗ The L1 dimension is the dimension without an I/O module. Add 54 mm to this dimension for each I/O module. n2 is the number of I/O module stations.
Stations n1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 188.1 198.6 209.1 219.6 230.1 240.6 251.1 261.6 272.1 282.6 293.1 303.6 314.1 324.6 335.1 345.6 356.1 366.6 377.1 387.6 398.1 408.6 419.1
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
129
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Type 10/Side Ported
manual override)
(Slide locking
78.9
73.2
1 P 1 P
S
61.5
2 B2 B2 B2 B2 B
33.4
3/5 3/5
29.1
E E
4 A4 A4 A4 A4 A
8.7
12.4
14.1
[1(P), 3/5(E) port] P = 16
Applicable tube O.D Ø 10 (20.5)
Ø 3/8"
1 3 1 3
X2 4 6 X3 X2 4 6 X3 B A B A B A B A
14 A 14 A 14 A 14 A
83
97.5
113.4
120
5 7 5 7
X4 8 10 X5
81.2
5.5
9 11
14.5
X6 12 14 X7 12 B 12 B 12 B 12 B
13 15
10.9
4.7
17.5
7.5
<SS5Y5-10SACN>
1 P
2 B2
3/5 E
4 A4
BA
14 A
12
27.7
L3 = 54 x n2 + 113.1
U C6,N7
SS5Y7-10SA - Stations DB - C8,N9
C10,N11
One-touch fitting
C12,CM [4(A),2(B) port]
Applicable tube O.D C6 : Ø 6
C8 : Ø 8
C10 : Ø 10
C12 : Ø 12
N7 : Ø 1/4"
N9 : Ø 5/16"
85.8
82.7
1 P 1 P
S
2 B2 B2 B2 B2 B
61.5
56.6
35.2
3/5 E 3/5 E
31.6
4 A4 A4 A4 A4 A
(Pitch)
8.7
11.1
14.2
One-touch fitting 25 P = 19
[1(P), 3/5(E) port] 20.5
Applicable tube O.D C12 : Ø 12 (21.7)
N13 : Ø 1/2"
3 x M5 Mounting hole
D side U side
L1
5.5 L3 L2 1.5 Light/surge voltage suppressor
54 54 85
Manual override
Marker Push-turn locking slotted type:
mounting hole (Press, then rotate it. )
Output Input 4(A) port side: Blue (For rubber seal) 90
connector connector SI Unit : Grey (For metal seal)
2(B) port side: Yellow
X0 0 2 X1 X0 0 2 X1
1 3 1 3
B A B A B A B A
X2 4 6 X3 X2 4 6 X3
83
14 A 14 A 14 A 14 A
120
128.8
115
5 7 5 7
X4 8 10 X5
14.5
96.7
9 11
X6 12 14 X7
5.5
12 B 12 B 12 B 12 B
13 15
17.5
7.5
8.8
3.9
(Station 1) (Station n)
End plate Digital input module 4 x M5 Mounting hole
Digital output module (Fitting for the type with P/E ports
on the U and/or D sides)
<SS5Y7-10SACN>
BA
14 A
∗ These figures show the “SS5Y7-10SAANY2-05D-C10”.
∗ Refer to page 179 for dimensions of external pilot, silencer and elbow fittings.
∗ Refer to page 184 for dimensions of A or B port top-ported type.
12 B
27.7
FE terminal (M4)
1 P
2 B2
3/5 E
4 A4
L3 = 54 x n2 + 113.3
···
···
···
···
Example (SS5Y3-12SAAN-)
3-position closed centre SS5Y3-12SAANY2-05DS-N ·····1 set (Type 12 5-station manifold base part no.)
2-position double (24 VDC)
(24 VDC) ∗SY3130-5U1-C6 ·····················3 sets (2-position single part no.)
SY3200-5U1 (1 set)
SY3300-5U1 (1 set) ∗SY3220-5U1-C6 ·····················1 set (2-position double part no.)
2-position single (24 VDC) ∗SY3330-5U1-C6 ·····················1 set (3-position closed centre part no.)
SY3100-5U1 (3 sets) ∗EX245-DX1 ····························1set I/O module part no.
Digital input module ∗EX245-DY1 ····························1set I/O module part no.
EX245-DX1 The asterisk denotes the symbol for assembly.
Digital output module Prefix it to the part numbers of the valve etc.
EX245-DY1
ide
• The valve arrangement is numbered as the 1st station from the D side.
Us
• The I/O module station arrangement is numbered starting from the SI unit side.
ns
io
at
St
2
3 • Under the manifold part number, state the valves to be mounted, then the I/O
1
ide module in order from the 1st station as shown in the figure above. If the
Ds
arrangement becomes complicated, specify on a manifold specification sheet.
∗1: Do not enter the SI Unit part number and the end plate part number
SI Unit∗1
1
together.
EX245-SPN1A
∗: When mixing top ported configurations, select from page 133. In this case, use caution as there
2 End plate∗1 is also output on the A and B port on base side.
s
Sta
tion EX245-EA2-3 Specify on a manifold specification sheet if plugs are required on the A and B port on base side.
132
SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top mounted
r Pilot type
— Internal pilot
o Light/surge voltage suppressor !2 Thread type
R External pilot and common specification — Rc
Surge voltage Common F G
With light
suppressor specification N NPT
R — T NPTF
t Back pressure check valve U
Non-polar
∗: Only — is available for M5.
— None NS — Negative
H∗1 Built-in NZ common
∗1: Select the rubber seal type when the back
pressure check valve is built-in. Manifold
∗: Select “NZ” for with the power saving circuit. !3 Type of mounting screw
installed type is available if the back — Round head combination screw
B Hexagon socket head cap screw
pressure check valve is required for a valve
with metal seal. For ordering example, refer !0 Manual override Round head combination screw
K (Falling-out-prevention type)∗1
to page 236. However, it is not —: D:
recommended to use the built-in valve type Non-locking Push-turn Hexagon socket head cap screw
and the manifold installed type at the same push locking
H (Falling-out-prevention type)∗1
time because it will reduce the flow. (slotted) ∗1: For “K” and “H”, the valve body cover has a
∗: The built-in valve type back pressure check drop prevention construction to stop the
valve is not available for the 3-position type or mounting screws from falling out when the
the SY7000. valve is removed for maintenance etc.
∗: When ordering a valve individually, the
E: F: base gasket is not included.
Push-turn Slide locking Since the base gasket is attached to the
locking (manual) manifold, please order the base gasket
(manual) separately if it is needed for maintenance
service.
∗: Select “—” or “K” for the optional individual
SUP/EXH spacer assembly, interface
regulator or double check spacer assembly
∗: Refer to page 36 for with the safety slide with residual pressure release valve.
locking manual override.
Protective class
class # (Mark: )
133
Plug-in Connector Connecting Base
Type 10
Side Ported EX250
SY3000/5000/7000 Series
Type 11
Bottom Ported
RoHS
How to Order Manifolds
···
r Input block stations
···
unit.
∗ The supply current from the SI unit of 16 16 stations
— None 02 2 stations
AS-Interface applicable 1 power supply Specified layout∗2
1 1 station
···
···
system specification to the input block and (Up to 32 solenoids available)
···
···
Straight
C4 Ø4 — — N7 Ø 1/4"
Straight
C6 Ø6 N9 Ø 5/16" —
C8 Ø8 — N11 Ø 3/8" — — —
C10 Ø 10 — — — CM∗1 Straight port, mixed sizes
C12 Ø 12 — — — LN3 Ø 5/32" — — — —
Upward
CM∗1 Straight port, mixed sizes LN7 Ø 1/4" — — —
L4 Ø4 — — — LN9 Ø 5/16" — — — —
L6 Ø6 — — LN11 Ø 3/8" — — — —
Upward
Elbow∗2
L8 Ø8 — — — BN3 Ø 5/32" — — — —
Downward
L10 Ø 10 — — — — BN7 Ø 1/4" — — —
L12 Ø 12 — — — — BN9 Ø 5/16" — — — —
Elbow∗2
B4 Ø4 — — — BN11 Ø 3/8" — — — —
Downward
P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).
···
BA — length of specified
D — — 24 For 24 stations stations.
DIN rail
A mounting
B —
∗ Enter the number of stations inside when it is larger than the number
of valve stations. (Refer to “DIN Rail Option” above.)
∗ Only direct mounting is available for the type 11 bottom-ported type.
∗ Refer to page 319 for the fixation of DIN rail mounting type manifold.
∗ If the DIN rail must be mounted without an SI unit, select D0. Then,
refer to L3 of the dimensions for the DIN rail length and order
separately. (Refer to page 227 for the DIN rail part number.)
Protective class
class # (Mark: )
135
Plug-in Connector Connecting Base SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted
w Type of actuation
1
2-position
Single u Coil type E: F:
2 Double — Standard Push-turn Slide locking
3 Closed centre T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit lever
5 Pressure centre type if the valve is to be continuously type
A∗1 N.C./N.C. energised for long periods of time.
B∗1
4-position
N.O./N.O. ∗ Be careful of the energising time when the
dual 3-port power saving circuit is selected. Refer to
C∗1 N.C./N.O.
page 316 for details. ∗ Refer to page 36 for the safety slide locking
∗1 Only the rubber seal type is available for the manual override.
4-position dual 3-port valve.
i Rated voltage
5 24 VDC
!1 Type of mounting screw
e Seal type — Round head combination screw
0 Rubber seal B Hexagon socket head cap screw
1 Metal seal o Light/surge voltage suppressor K Round head combination screw (Drop prevention type)
and common specification H Hexagon socket head cap screw (Drop prevention type)
Surge voltage Common ∗ For “K” and “H,” the valve body cover has a
Symbol With light
r Pilot type R —
suppressor specification drop prevention construction to stop the
mounting screws from falling out when the
— Internal pilot Non-polar valve is removed for maintenance, etc.
U
R External pilot ∗ When ordering a valve individually, the
S — Positive base gasket is not included.
Z common Since the base gasket is attached to the
NS — Negative manifold, please order the base gasket
t Back pressure check valve NZ common separately if it is needed for maintenance.
Refer to page 222 for base gasket and
(Built-in valve type) ∗ “R" and “U” are applicable for every SI unit.
mounting screw part numbers.
However, “S” and “Z” can be used only for
— None ∗ “B” and “H” cannot be selected for the
CC-Link applicable unit and “NS” and “NZ”
H Built-in
are for units which are not CC-Link
individual SUP/EXH spacer assembly,
∗ Only the rubber seal type is available. A interface regulator, or double check spacer
applicable.
assembly with residual pressure release
manifold installed type is available if a back ∗ For the non-polar type, be careful of surge
pressure check valve with a metal seal is valve.
voltage intrusion.
required. Refer to page 236 for ordering Refer to page 317 for details.
examples. However, it is not recommended ∗ Only “Z” and “NZ” types are available with a
to use the built-in valve type and the manifold power saving circuit.
installed type at the same time because it will
reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.
Protective class
class # (Mark: )
136
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
C2
U
SS5Y3-10S- Stations D - C3, N1
C4, N3 (D)
B C6, N7
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 2
One-touch fitting : Ø 3.2, Ø 1/8"
[1(P), 3/5(E) port] (Station 1)---(Station n)
: Ø 4, Ø 5/32"
Applicable tube O.D.: Ø 8, Ø 5/16" : Ø 6, Ø 1/4"
1 P 1 P
0
BUS
13.6
10.6
63.1
1
56.6
60
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2
2
PWR
21.6
4 A4 A4 A4 A4 A
3
18
13.2
11.8
18.3 15.5 P = 10.5 (17.8)
4 x M8 2 x M12
3-pin socket
D side U side
8
B A B A B A B A B A
5.5
92.6
14 A 14 A 14 A 14 A 14 A
35
83
0
1
66
60.5
2
40.9
3
4.6
12 B 12 B 12 B 12 B 12 B
4.6
2.7
1.7
) C6: 3.6
N7: 7.4
SI unit
(4.9)
7.5
L1 = 10.5 x n1 + 135.5 + 21 x n2 ∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
L2 = 10.5 x n1 + 42 ∗ These figures show the “SS5Y3-10SQ1A-05D-C6.”
L4 = L3 – 10.5 ∗ Refer to page 182 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 21 x n2 + 82
n1: Valve stations
n2: Input block stations
L3: DIN Rail Overall Length
Valve
stations
(n1) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Input
block
stations (n2)
0 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423
1 210.5 223 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5
2 223 235.5 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5
3 248 260.5 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5
4 273 285.5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498
5 285.5 298 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523
6 310.5 323 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548
7 335.5 348 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548 548 560.5
8 348 360.5 373 385.5 398 410.5 423 423 435.5 448 460.5 473 485.5 485.5 498 510.5 523 535.5 548 548 560.5 573 585.5
137
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C4, N3
SS5Y5-10S- Stations D - C6, N7 (D)
B C8, N9 One-touch fitting
[4(A), 2(B) port]
(Station 1)----------- (Station n) Applicable tube O.D.: Ø 4, Ø 5/32"
One-touch fitting : Ø 6, Ø 1/4"
[1(P), 3/5(E) port] : Ø 8, Ø 5/16"
Applicable tube O.D.: Ø 10, Ø 3/8"
0
BUS 1 P 1 P
73.2
1 2 B2 B2 B2 B2 B
56.6
60
12.4
13.2
2
33.4
3/5 E 3/5 E
29.1
PWR
3
4 A4 A4 A4 A4 A
14.1
8.7
(For DIN rail
mounting)
7.5
M3 (Pitch)
11.8
20 18 P = 16 (20.5)
4 x M8 2 x M12
3-pin socket
D side U side
(L5) L1
Manual override∗1
18 21 63
DIN rail holding screw
(For DIN rail mounting)
( Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
DIN rail holding screw Light/surge voltage suppressor : Grey (For metal seal)
(For DIN rail mounting) 2(B) port side : Yellow
Input block
DIN rail SI unit
8
BA BA BA BA BA
5.5
14 A 14 A 14 A 14 A 14 A
35
97.5
113.4
1
66
2
81.2
3
61.7
5.5
12 B 12 B 12 B 12 B 12 B
23.5
10.9
4.7
(5.9)
2 x M4 mounting hole
(8.3)
4 x M5 mounting hole
5.5 L6 L2 1.5 (Fitting for the type with P/E
ports on the U and/or D sides)
5.3 L4
(DIN rail mounting hole pitch: 12.5)
L3
L1 = 16 x n1 + 141.5 + 21 x n2 ∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
L2 = 16 x n1 + 48 ∗ These figures show the “SS5Y5-10SQ1A-05D-C8.”
L4 = L3 – 10.5 ∗ Refer to page 183 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 21 x n2 + 81.5
n1: Valve stations
n2: Input block stations
L3: DIN Rail Overall Length
Valve
stations
(n1) 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Input
block
stations (n2)
0 198 223 235.5 248 273 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 560.5
1 223 235.5 260.5 273 285.5 298 323 335.5 348 373 385.5 398 410.5 435.5 448 460.5 485.5 498 510.5 523 548 560.5 573
2 248 260.5 273 298 310.5 323 335.5 360.5 373 385.5 410.5 423 435.5 448 473 485.5 498 523 535.5 548 560.5 585.5 598
3 260.5 285.5 298 310.5 335.5 348 360.5 373 398 410.5 423 448 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 623
4 285.5 298 323 335.5 348 373 385.5 398 410.5 435.5 448 460.5 473 498 510.5 523 548 560.5 573 585.5 610.5 623 635.5
5 310.5 323 335.5 360.5 373 385.5 398 423 435.5 448 473 485.5 498 510.5 535.5 548 560.5 585.5 598 610.5 623 648 660.5
6 323 348 360.5 373 398 410.5 423 435.5 460.5 473 485.5 510.5 523 535.5 548 573 585.5 598 623 635.5 648 660.5 685.5
7 348 360.5 385.5 398 410.5 435.5 448 460.5 473 498 510.5 523 548 560.5 573 585.5 610.5 623 635.5 648 673 685.5 698
8 373 385.5 398 423 435.5 448 473 485.5 498 510.5 535.5 548 560.5 573 598 610.5 623 648 660.5 673 685.5 710.5 723
138
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
C6, N7
U
SS5Y7-10S- Stations D - C8, N9
C10, N11 (D)
B C12 One-touch fitting
[4(A), 2(B) port ]
(Station 1) (Station n) Applicable tube O.D.: Ø 6, Ø 1/4"
One-touch fitting : Ø 8, Ø 5/16"
[1(P), 3/5(E) port] : Ø 10, Ø 3/8"
Applicable tube O.D.: Ø 12, Ø 1/2" : Ø 12
2
82.7
0 1 P 1 P
BUS 2 B2 B2 B2 B2 B
1
56.6
60
13.2
14.2
11.1
2 3/5 E 3/5 E
35.2
8.7
31.6
PWR 4 A4 A4 A4 A4 A
3
(For DIN rail
(10)
M3 (Pitch)
mounting)
25 20.5 P = 19 (21.7)
2 x M12
(14.3)
4 x M8
3-pin socket
D side U side
(L5) L1 Manual override∗1
B A B A B A B A B A
(35)
14 A 14 A 14 A 14 A 14 A
0
1
66
128.8
115
2
3
(5.5)
96.7
(77.1)
12 B 12 B 12 B 12 B 12 B
5.5
38.9
2 x M4
8.8
3.9
(6)
mounting hole
(9.3)
4 x M5 mounting hole
(17.9)
L1 = 19 x n1 + 149.7 + 21 x n2 ∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
L2 = 19 x n1 + 56 ∗ These figures show the “SS5Y7-10SQ1A-05D-C10.”
L4 = L3 – 10.5 ∗ Refer to page 184 for dimensions of A or B port top-ported type.
L5 = (L3 – L1)/2
L6 = 21 x n2 + 81.7
n1: Valve stations
n2: Input block stations
SY3000/5000/7000 Series
Type 12 ®
Top Ported
RoHS
How to Order Manifolds
···
N
···
7 SY7000 PROFIBUS DP (Negative common)
TA 2 power 8 in/8 out, 31 slave modes 16 16 stations
TB AS-Interface supply 4 in/4 out, 31 slave modes
systems 02 2 stations
(Negative 1 power Specified layout∗2
e Input block stations
···
TC 8 in/8 out, 31 slave modes
···
common) supply (Up to 32 solenoids available)
— None TD system 4 in/4 out, 31 slave modes 24 24 stations
1 1 station Y CANopen (Negative common) ∗1 Double wiring: 2-position single, double,
ZE EtherNet/IP™ (Negative common) 3-position, and 4-position valves can be used
···
···
Symbol
S
2 3 — Ø8 Ø 10 Ø 12
e
1
D sid
N Ø 5/16" Ø 3/8" Ø 1/2"
Manifold base (5 stations) ∗ For N, sizes are in inches.
SS5Y3-12SQ1C-05D
i Mounting ∗ If the DIN rail must be mounted
SS5Y3-12SQ1C-05D ··· 1 set (Type 12 5-station manifold base part no.)
— Direct mounting without an SI unit, select D0. Then,
∗SY3130-5U1-C6 ··········· 3 sets (2-position single part no.) D DIN rail mounting (With DIN rail) refer to L3 of the dimensions for the
D0 DIN rail mounting (Without DIN rail) DIN rail length and order separately.
∗SY3230-5U1-C6 ··········· 1 set (2-position double part no.) (Refer to page 227 for the DIN rail
∗SY3330-5U1-C6 ··········· 1 set (3-position closed centre part no.) D3 For 3 stations Specify a length
part number.)
···
···
The asterisk denotes the symbol for the assembly. longer than that of ∗ Refer to page 319 for the fixation of
Prefix it to the part numbers of the valve, etc. D24 For 24 stations the standard rail. DIN rail mounting type manifold.
• For the valve arrangement, the valve closest to the D side is considered the 1st station. For details on the EX250 Integrated Type (For Input/Output) Serial
• Under the manifold part number, state the valves to be mounted in order starting Transmission System, refer to the Web Catalogue and the Operation
with the 1st station as shown in the figure above. If the arrangement becomes too Manual. For the part numbers of the SI units to be mounted, refer to page
complicated, specify the details on a manifold specification sheet. 215. Please download the Operation Manual via the SMC website, https://
www.smc.eu
140
SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported
Protective class
class # (Mark: )
141
Plug-in Connector Connecting Base
Type 10
Side Ported EX260
SY3000/5000/7000 Series
Type 11
Bottom Ported
®
Refer to page 1 4 5 for details on manifolds that
support safety communication (PROFIsafe).
RoHS
How to Order Manifolds
w Type 16 16 stations
02 2 stations y SUP/EXH block assembly
10 Side ported Specified layout∗2 — Internal pilot
…
142
SY3000/5000/7000 Series
Straight
C4 Ø4 — — N7 Ø 1/4"
Straight
C6 Ø6 N9 Ø 5/16" —
C8 Ø8 — N11 Ø 3/8" — — —
C10 Ø 10 — — — CM∗1 Straight port, mixed sizes
C12 Ø 12 — — — LN3 Ø 5/32" — — — —
Upward
CM∗1 Straight port, mixed sizes LN7 Ø 1/4" — — —
L4 Ø4 — — — LN9 Ø 5/16" — — — —
L6 Ø6 — — LN11 Ø 3/8" — — — —
Upward
Elbow∗2
L8 Ø8 — — — BN3 Ø 5/32" — — — —
Downward
L10 Ø 10 — — — — BN7 Ø 1/4" — — —
L12 Ø 12 — — — — BN9 Ø 5/16" — — — —
Elbow∗2
B4 Ø4 — — — BN11 Ø 3/8" — — — —
Downward
P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).
Example (SS5Y3-10SNAN-)
SS5Y3-10SNAN-04D-C6···1 set (Type 10 4-station manifold base part no.)
2-position single (24 VDC) 2-position double (24 VDC) ∗SY3100-5U1·····················2 sets (2-position single part no.)
SY3100-5U1 (2 sets) SY3200-5U1 (1 set) ∗SY3200-5U1·····················1 set (2-position double part no.)
3-position closed centre (24 VDC) ∗SY3300-5U1·····················1 set (3-position closed centre part no.)
SY3300-5U1 (1 set)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
3
2 ∗ When mixing top-ported configurations, select from those listed on
1
e page 152. Specify on the manifold specification sheet if plugs are
Manifold base (4 stations) sid
D required for the A and B ports on the manifold.
SS5Y3-10SNAN-04D-C6
Protective class
class # (Mark: )
143
Plug-in Connector Connecting Base SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted
w Type of actuation
1
2-position
Single u Coil type
2 Double — Standard E: F:
3 Closed centre T With power saving circuit (Continuous duty type) Push-turn Slide locking
4 3-position Exhaust centre locking lever type
∗ Be sure to select the power saving circuit
5 Pressure centre type
type if the valve is to be continuously
A∗1 N.C./N.C. energised for long periods of time.
4-position ∗ Be careful of the energising time when the
B∗1 dual 3-port
N.O./N.O.
C∗1 N.C./N.O. power saving circuit is selected. Refer to
page 316 for details.
∗1 Only the rubber seal type is available for the
∗ Refer to page 36 for the safety slide locking
4-position dual 3-port valve.
i Rated voltage manual override.
5 24 VDC
Protective class
class # (Mark: )
144
Plug-in Connector Connecting Base
Type 10
Side Ported EX260 Safety Communication Protocol (PROFIsafe)
SY3000/5000/7000 Series
Type 11
Bottom Ported
®
Using the safety communication protocol
Refer to the EX260 Web Catalogue for details on units that support the safety communication protocol. RoHS
When using a manifold valve within an ISO 1 3 8 4 9 -compliant safety system, the device needs to be
considered from both the pneumatic circuit and the electric side.
Devices (including valves) need to be selected based on whether their functions are in line with the
safety level of the equipment as a whole.
The use of valves that have been validated as being compliant with ISO 13849-2 may be required.
For details on valves that have been validated, please contact SMC.
In addition, refer to “Safety Instructions” for precautions on model selection.
Refer to for details on manifolds that support
Fieldbus and Industrial Ethernet.
How to Order Manifolds
R External pilot
16 16 stations ∗ 3/5(E) port is plugged for the built-in silencer
w Type 02 2 stations
Specified layout∗2
type.
∗ When the built-in silencer type is used, keep
…
10 Side ported (Up to 32 solenoids available) the exhaust port from coming into direct
24 24 stations
11 Bottom ported∗1 contact with water or other liquids.
∗1 The SY5000 manifold base is used for the ∗1 Double wiring: 2-position single, double,
bottom-ported SY3000. When ordering, 3-position, and 4-position valves can be
refer to the “Plug-in Mixed Type Manifold” used on all manifold stations.
Use of a 2-position single solenoid will
Refer to the page on the right for u.
(from page 185).
result in an unused control signal. If this is
For details on the EX260 Integrated Type (For Output) Serial Transmission System, refer to the Web Catalogue and the Operation Manual. For the part
numbers of the SI units to be mounted, refer to page 216. Please download the Operation Manual via the SMC website, https://www.smc.eu
145
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Straight
C4 Ø4 — — N7 Ø 1/4"
Straight
C6 Ø6 N9 Ø 5/16" —
C8 Ø8 — N11 Ø 3/8" — — —
C10 Ø 10 — — — CM∗1 Straight port, mixed sizes
C12 Ø 12 — — — LN3 Ø 5/32" — — — —
Upward
Elbow∗2
L8 Ø8 — — — BN3 Ø 5/32" — — — —
Downward
B4 Ø4 — — — BN11 Ø 3/8" — — — —
Downward
P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).
Protective class
class # (Mark: )
146
SY3000/5000/7000 Series
∗ 2 -position double of rubber seal and manual override with locking function
(D, E, F type) are excluded, because they don’t comply with safety standard.
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted
w Type of actuation
1
2-position
Single u Coil type
2 Double∗2 — Standard
3 Closed centre T With power saving circuit (Continuous duty type)
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit !1 Type of mounting screw
5 Pressure centre type if the valve is to be continuously — Round head combination screw
A∗1 N.C./N.C. energized for long periods of time.
B Hexagon socket head cap screw
4-position ∗ Be careful of the energizing time when the
B∗1 dual 3-port
N.O./N.O. Round head combination screw
C∗1 N.C./N.O. power saving circuit is selected. Refer to K (Drop prevention type)
page 316 for details.
∗1 Only the rubber seal type is available for the Hexagon socket head cap screw
4-position dual 3-port valve. H (Drop prevention type)
∗2 Except the rubber seal i Rated voltage ∗ For “K” and “H,” the valve body cover has a
5 24 VDC drop prevention construction to stop the
mounting screws from falling out when the
e Seal type valve is removed for maintenance, etc.
∗ When ordering a valve individually, the
0
1
Rubber seal
Metal seal
o Light/surge voltage suppressor base gasket is not included.
and common specification Since the base gasket is attached to the
manifold, please order the base gasket
Surge voltage Common separately if it is needed for maintenance.
Symbol With light
suppressor specification
r Pilot type
Refer to page 222 for base gasket and
— — — mounting screw part numbers.
— Internal pilot R — Non-polar ∗ “B” and “H” cannot be selected for the
R External pilot U individual SUP/EXH spacer assembly,
interface regulator, or double check spacer
NS — Negative
assembly with residual pressure release
NZ common
valve.
t Back pressure check valve ∗ For the non-polar type, be careful of surge
voltage intrusion.
(Built-in valve type) Refer to page 317 for details.
— None ∗ Only “NZ” type is available with a power
H Built-in saving circuit.
∗ Only the rubber seal type is available. A
manifold installed type is available if a back
pressure check valve with a metal seal is
required. Refer to page 236 for ordering
examples. However, it is not recommended
to use the built-in valve type and the manifold
installed type at the same time because it will
reduce the flow.
∗ The back pressure check valve is not available
for the 3-position type or the SY7000.
147
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
C2,
U
SS5Y3-10S- Stations D - C3, N1
C4, N3 (D)
B C6, N7
One-touch fitting
One-touch fitting [4(A), 2(B) port]
[1(P), 3/5(E) port] Applicable tube O.D.: Ø 2
Applicable tube O.D.: Ø 8, Ø 5/16" : Ø 3.2, Ø 1/8"
(Station 1)----------- (Station n) : Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
manual override)
BUS OUT
[Communication connector D-sub]
(Slide locking
1 P 1 P
76.7
63.1
68.8
10.6
13.6
BUS IN
56.6
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2
PWR
21.6
4 A4 A4 A4 A4 A BUS
18
1 P
76.7
3/5 E 2 B2
46.5 (17.8)
(7.5)
(11.8)
PWR 4 A4
15.5 (Pitch)
P=10.5
46.5
D side U side
Manual override∗1
(
Push-turn locking slotted type:
Press, then rotate it. )
DIN rail holding screw (L5) 4(A) port side : Blue (For rubber seal)
L1
: Grey (For metal seal)
(For DIN rail mounting)
2(B) port side : Yellow
Light/surge voltage
suppressor (8)
DIN rail
(5.5)
B A B A B A B A
(35)
92.6
14 A 14 A 14 A 14 A
83
80.2
60.5
(40.9)
4.6
12 B 12 B 12 B 12 B
22.2
4.6
1.7
(4.9)
L2 1.5
(5.3) L4
(DIN rail mounting hole pitch: 12.5)
(L3)
∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10SQA-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
L1 103.7 114.2 124.7 135.2 145.7 156.2 166.7 177.2 187.7 198.2 208.7 219.2 229.7 240.2 250.7 261.2
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210 220.5
L3 135.5 148 148 160.5 173 185.5 198 210.5 223 223 235.5 248 260.5 273 285.5 285.5
L4 125 137.5 137.5 150 162.5 175 187.5 200 212.5 212.5 225 237.5 250 262.5 275 275
L5 16 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12
n: Stations 18 19 20 21 22 23 24
L1 271.7 282.2 292.7 303.2 313.7 324.2 334.7
L2 231 241.5 252 262.5 273 283.5 294
L3 298 310.5 323 335.5 348 348 360.5
L4 287.5 300 312.5 325 337.5 337.5 350
L5 13 14 15 16 17 12 13
148
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C4, N3
SS5Y5-10S- Stations DB - C6, N7 (D)
C8, N9
One-touch fitting
[4(A), 2(B) port]
One-touch fitting Applicable tube O.D.:: Ø 4, Ø 5/32"
[1(P), 3/5(E) port] : Ø 6, Ø 1/4"
Applicable tube O.D.: Ø 10 (Station 1)----------- (Station n) : Ø 8, Ø 5/16"
: Ø 3/8"
manual override)
(Slide locking
BUS OUT
78.9
76.7
14.1
1 P 1 P
73.2
BUS IN 2 B2 B2 B2 B2 B
56.6
BUS
3/5 3/5
33.4
E E
76.7
1 P
29.1
PWR
2 B2
4 A4 A4 A4 A4 A
3/5 E
PWR
8.7
12.4
4 A4
(11.8)
(Pitch) (20.5)
(7.5)
48.2 18 P=16
48.2
D side U side
Manual override∗1
(
Push-turn locking slotted type:
Press, then rotate it. )
DIN rail holding screw (L5) 4(A) port side : Blue (For rubber seal)
L1
(For DIN rail mounting) : Grey (For metal seal)
2(B) port side : Yellow
Light/surge voltage suppressor
(8)
DIN rail
(5.5)
B A B A B A B A
(35)
14 A 14 A 14 A 14 A
97.5
113.4
101
81.2
(61.7)
5.5
12 B 12 B 12 B 12 B
10.9
1.4
4.7
(5.9)
(8.3)
SI unit
4 x M5 mounting hole
34.2 L2 1.5
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5) (Fitting for the type with P/E
(L3) ports on U and/or D sides)
∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10SQA-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
L1 120.7 136.7 152.7 168.7 184.7 200.7 216.7 232.7 248.7 264.7 280.7 296.7 312.7 328.7 344.7 360.7
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304 320
L3 148 160.5 185.5 198 210.5 235.5 248 260.5 273 298 310.5 323 348 360.5 373 385.5
L4 137.5 150 175 187.5 200 225 237.5 250 262.5 287.5 300 312.5 337.5 350 362.5 375
L5 13.5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14 12.5
n: Stations 18 19 20 21 22 23 24
L1 376.7 392.7 408.7 424.7 440.7 456.7 472.7
L2 336 352 368 384 400 416 432
L3 410.5 423 435.5 448 473 485.5 498
L4 400 412.5 425 437.5 462.5 475 487.5
L5 17 15 13.5 11.5 16 14.5 12.5
149
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
C6, N7
U
SS5Y7-10S- Stations D - C8, N9
C10, N11 (D)
B C12
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 12, Ø 1/2"
(Station 1) (Station n)
[Communication connector D-sub]
2
BUS OUT
BUS
82.7
1 P 1 P
76.7
1 P
76.7
2 B2 B2 B2 B2 B
BUS IN 2 B2
56.6
11.1
3/5 E 3/5 E
35.2
8.7
31.6
PWR 4 A4 A4 A4 A4 A 3/5 E
PWR 4 A4
14.2
(14.3)
(Pitch)
53.2 20.5 P = 19 One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
: Ø 12
D side U side
(L5) L1
Manual override∗1
DIN rail holding screw
(For DIN rail mounting) Light/surge voltage suppressor
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
2(B) port side: Yellow
B A B A B A B A
(35)
14 A 14 A 14 A 14 A 14 A
102.3
128.8
115
(5.5)
96.7
(77.1)
12 B 12 B 12 B 12 B 12 B
5.5
14
8.8
3.9
SI unit
(6)
(9.3)
∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10SQA-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
L1 134.9 153.9 172.9 191.9 210.9 229.9 248.9 267.9 286.9 305.9 324.9 343.9 362.9 381.9 400.9 419.9 438.9 457.9 476.9 495.9 514.9 533.9 552.9
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360 379 398 417 436 455 474 493 512
L3 160.5 185.5 198 223 235.5 260.5 273 298 310.5 335.5 348 373 398 410.5 435.5 448 473 485.5 510.5 523 548 560.5 585.5
L4 150 175 187.5 212.5 225 250 262.5 287.5 300 325 337.5 362.5 387.5 400 425 437.5 462.5 475 500 512.5 537.5 550 575
L5 13 16 12.5 15.5 12.5 15.5 12 15 12 15 11.5 14.5 17.5 14.5 17.5 14 17 14 17 13.5 16.5 13.5 16.5
150
Plug-in Connector Connecting Base
EX260
Type 12
SY3000/5000/7000 Series
®
Top Ported
RoHS
How to Order Manifolds
…
∗1 t For type “S”, SUP/EXH block assembly with
w SI unit specifications 16 16 stations a built-in silencer, choose U or D for P, E port
(Output polarity, Protocol, Number of outputs, Communication connector) 02 2 stations entry.
Specified layout∗2
…
D-sub (Up to 16 solenoids available) D side, the silencer exhaust port is on the U side.)
ND NDN 16 16 16 stations ∗ When the built-in silencer type is used, keep the
VA VAN 32 ∗1 Double wiring: 2-position single, double, exhaust port from coming into direct contact with
CC-Link M12
VB VBN 16 3-position, and 4-position valves can be used water or other liquids.
DA DAN 32 on all manifold stations.
DB DBN
EtherCAT
16
M12 Use of a 2-position single solenoid will result in
an unused control signal. If this is not desired,
y P, E port size (One-touch fittings)
FA FAN 32 order with a specified layout. Symbol SY3000 SY5000 SY7000
PROFINET M12
FB FBN 16 ∗2 Specified layout: Indicate the wiring
EA EAN 32 specifications on the manifold specification — Ø8 Ø 10 Ø 12
EtherNet/IP™ M12 sheet.
EB EBN 16 N Ø 5/16" Ø 3/8" Ø 1/2"
(Note that 2-position double, 3-position, and
—∗3 GAN Ethernet 32
M12 4-position valves cannot be used where single ∗ For N, sizes are in inches.
—∗3 GBN POWERLINK 16 wiring has been specified.)
—∗3 KAN IO-Link 32∗5 M12 ∗ This also includes the number of the blanking
plate assembly.
u Mounting
∗1 Without SI unit, the output polarity is decided — Direct mounting
by the SI unit used. ∗ For the model without the SI unit (S0), note the
Ensure a match with the common specification maximum number of solenoids of the SI unit that D DIN rail mounting (With DIN rail)
of the valves to be used. will be mounted. If the layout is specified, D0 DIN rail mounting (Without DIN rail)
∗2 DIN rail cannot be mounted without SI unit. indicate it on the manifold specification sheet.
D3 For 3 stations Specify a length longer
∗3 Positive common (NPN) type is not applicable.
…
order starting with the 1st station as shown in the figure above. If the
tio
ta
S
SS5Y3-12SNAN-04D
151
Plug-in Connector Connecting Base SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported
Protective class
class # (Mark: )
152
Plug-in Connector Connecting Base
Type 10
Side Ported EX126
Type 11
Bottom Ported
SY3000/5000/7000 Series
RoHS
How to Order Manifolds
…
7 SY7000 ∗1 The SY5000 manifold base is used for the
bottom-ported SY3000. When ordering, 08 8 stations
refer to the “Plug-in Manifold Mixed 02 2 stations
Mounting Type” (from page 185). Specified layout∗2
…
(Up to 16 solenoids available)
16 16 stations
∗1 Double wiring: 2-position single, double,
e SI unit 3-position, and 4-position valves can be
0 Without SI unit used on all manifold stations.
V CC-Link (Positive common NPN) Use of a 2-position single solenoid will
result in an unused control signal. If this is
∗ Only a terminal block plate is mounted for the
not desired, order with a specified layout.
valve without SI unit.
∗2 Specified layout: Indicate the wiring
specifications with the manifold
specification sheet. (Note that 2-position
double, 3-position, and 4-position valves
cannot be used where single wiring has
How to Order Manifold Assembly been specified.)
∗ This also includes the number of the
blanking plate assembly.
Example (SS5Y3-10S4V--)
t P, E port entry
2-position double (24 VDC)
2-position single (24 VDC) SY3200-5U1 (1 set)
SY3100-5U1 (3 sets) U U side (2 to 10 stations)
3-position closed
SI unit centre (24 VDC)
D D side (2 to 10 stations)
SY3300-5U1 (1 set) B Both sides (2 to 16 stations)
Straight
C4 Ø4 — — N7 Ø 1/4"
Straight
C6 Ø6 N9 Ø 5/16" —
C8 Ø8 — N11 Ø 3/8" — — —
C10 Ø 10 — — — CM∗1 Straight port, mixed sizes
C12 Ø 12 — — — LN3 Ø 5/32" — — — —
Upward
CM∗1 Straight port, mixed sizes LN7 Ø 1/4" — — —
L4 Ø4 — — — LN9 Ø 5/16" — — — —
L6 Ø6 — — LN11 Ø 3/8" — — — —
Upward
Elbow∗2
L8 Ø8 — — — BN3 Ø 5/32" — — — —
Downward
B4 Ø4 — — — BN11 Ø 3/8" — — — —
Downward
P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).
Protective class
class # (Mark: )
154
SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted
w Type of actuation
1
2-position
Single u Coil type E: F:
2 Double — Standard
Push-turn Slide locking
3 Closed centre T With power saving circuit (Continuous duty type) locking type
4 3-position Exhaust centre ∗ Be sure to select the power saving circuit lever
5 Pressure centre type if the valve is to be continuously type
A∗1 N.C./N.C. energised for long periods of time.
B∗1
4-position
N.O./N.O. ∗ Be careful of the energising time when the
dual 3-port power saving circuit is selected. Refer to
C∗1 N.C./N.O.
page 316 for details. ∗ Refer to page 36 for the safety slide locking
∗1 Only the rubber seal type is available for the manual override.
4-position dual 3-port valve.
i Rated voltage
e Seal type
5 24 VDC
!1 Type of mounting screw
— Round head combination screw
0 Rubber seal
B Hexagon socket head cap screw
1 Metal seal
o Light/surge voltage suppressor K Round head combination screw (Drop prevention type)
and common specification H Hexagon socket head cap screw (Drop prevention type)
Surge voltage Common ∗ For “K” and “H,” the valve body cover has a
r Pilot type Symbol With light
suppressor specification drop prevention construction to stop the
mounting screws from falling out when the
— Internal pilot R —
valve is removed for maintenance, etc.
Non-polar
R External pilot U ∗ When ordering a valve individually, the
S — Positive base gasket is not included.
Z common Since the base gasket is attached to the
∗ For the non-polar type, be careful of surge manifold, please order the base gasket
t Back pressure check valve voltage intrusion. separately if it is needed for maintenance.
(Built-in valve type) Refer to page 317 for details. Refer to page 222 for base gasket and
∗ Only “Z” type is available with a power saving mounting screw part numbers.
— None
circuit. ∗ “B” and “H” cannot be selected for the
H Built-in individual SUP/EXH spacer assembly,
∗ Only the rubber seal type is available. A interface regulator, or double check spacer
manifold installed type is available if a back assembly with residual pressure release
pressure check valve with a metal seal is valve.
required. Refer to page 236 for ordering
examples. However, it is not recommended
to use the built-in valve type and the manifold
installed type at the same time because it will
reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.
Protective class
class # (Mark: )
155
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C2
SS5Y3-10S4V- Stations D - C3, N1 ( )
D
B C4, N3 C6, N7
4 x G 1/2 One-touch fitting
Signal/Electrical entry [1(P), 3/5(E) port] One-touch fitting
Applicable tube O.D.: Ø 8, Ø 5/16" [4(A), 2(B) port]
2.6
1 P 1 P
63.1
13.6
10.6
56.6
55.4
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2
21.6
4 A4 A4 A4 A4 A
18
13.2
(7.5)
mounting)
(Pitch)
(11.8)
Terminal block plate assembly 107.1 15.5 P = 10.5 (17.8)
D side U side
Manual override∗1
(L5) L1
DIN rail holding screw
(For DIN rail mounting)
(Light/surge voltage suppressor) (
Push-turn locking slotted type:
Press, then rotate it. )
DIN rail holding screw 4(A) port side : Blue (For rubber seal)
DIN rail : Grey (For metal seal)
(For DIN rail mounting)
2(B) port side : Yellow
(5.5)
(8)
B A B A B A B A B A
(35)
14 A 14 A 14 A 14 A 14 A 92.6
83
116
42
80
60.5
(40.9)
4.6
12 B 12 B 12 B 12 B 12 B
36.6
4.6
1.7
11
)
(4.9)
15.4
C6: 3.6
N7: 7.4
4 x M4 55.4
Mounting hole
2 x M5 Mounting hole
(
∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10S4V-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 164.3 174.8 185.3 195.8 206.3 216.8 227.3 237.8 248.3 258.8 269.3 279.8 290.3 300.8 311.3
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210
L3 198 198 210.5 223 235.5 248 260.5 273 273 285.5 298 310.5 323 335.5 335.5
L4 187.5 187.5 200 212.5 225 237.5 250 262.5 262.5 275 287.5 300 312.5 325 325
L5 17 11.5 12.5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5 12
156
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C4, N3
SS5Y5-10S4V - Stations D - C6, N7 (D)
B C8, N9
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 10, Ø 3/8"
4 x G 1/2
Signal/Electrical entry
One-touch fitting
[4(A), 2(B) port]
2.6
1 P 1 P
14.1
73.2
8.7
2 B2 B2 B2 B2 B
56.6
55.4
3/5 3/5
33.4
E E
29.1
4 A4 A4 A4 A4 A
13.2
12.4
(7.5)
mounting)
(Pitch)
(20.5)
(11.8)
Terminal block 108.8 18 P = 16
plate assembly
(8)
B A B A B A B A B A
(35)
14 A 14 A 14 A 14 A 14 A
121.4
116
42
97.5
113.4
80
81.2
(61.7)
5.5
42.4
12 B 12 B 12 B 12 B 12 B
1
10.9
16.4
4.7
(5.9)
(8.3)
55.4
2 x M5 4 x M5 Mounting hole
Mounting hole
7.1 87.7 L2 1.5 (Fitting for the type with P/E
ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)
∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10S4V-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 181.3 197.3 213.3 229.3 245.3 261.3 277.3 293.3 309.3 325.3 341.3 357.3 373.3 389.3 405.3
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304
L3 210.5 223 248 260.5 273 285.5 310.5 323 335.5 360.5 373 385.5 398 423 435.5
L4 200 212.5 237.5 250 262.5 275 300 312.5 325 350 362.5 375 387.5 412.5 425
L5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5 16 14 12.5 17 15
157
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C6, N7
SS5Y7-10S4- Stations D - C8, N9 (D)
B C10, N11
C12
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 12, Ø 1/2"
4 x G1/2 SI unit
(2.6)
2
90.7
82.7
1 P 1 P
2 B2 B2 B2 B2 B
56.6
55.4
11.1
3/5 E 3/5 E
35.2
8.7
31.6
4 A4 A4 A4 A4 A
13.2
14.2
(14.3)
33.4 (Pitch)
Terminal block
113.8 20.5 P = 19
plate assembly One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
: Ø 12
D side U side
(L5) L1 Manual override∗1
DIN rail
holding screw DIN rail holding screw (Light/surge voltage suppressor) (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN (For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
rail mounting) : Grey (For metal seal)
2(B) port side: Yellow
B A B A B A B A B A
(35)
14 A 14 A 14 A 14 A 14 A
116
42
136.8
80
128.8
115
(5.5)
96.7
(77.1)
57.8
12 B 12 B 12 B 12 B 12 B
5.5
31.8
8.8
4 x M5
3.9
(6)
(9.3)
∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10S4V-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 195.5 214.5 233.5 252.5 271.5 290.5 309.5 328.5 347.5 366.5 385.5 404.5 423.5 442.5 461.5
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360
L3 223 248 260.5 285.5 298 323 335.5 360.5 373 398 410.5 435.5 448 473 485.5
L4 212.5 237.5 250 275 287.5 312.5 325 350 362.5 387.5 400 425 437.5 462.5 475
L5 14 17 13.5 16.5 13.5 16.5 13 16 13 16 12.5 15.5 12.5 15.5 12
158
Plug-in Connector Connecting Base
EX126
Type 12
Top Ported
SY3000/5000/7000 Series
RoHS
How to Order Manifolds
Example (SS5Y3-12S4V--)
y P, E port size (One-touch fittings)
2-position double (24 VDC)
SY3230-5U1-C6 (1 set) Symbol SY3000 SY5000 SY7000
2-position single (24 VDC)
SY3130-5U1-C6 (3 sets) 3-position closed — Ø8 Ø 10 Ø 12
centre (24 VDC)
SI unit N Ø 5/16" Ø 3/8" Ø 1/2"
SY3330-5U1-C6 (1 set)
∗ For N, sizes are in inches.
u Mounting
e — Direct mounting
sid
s
U D DIN rail mounting (With DIN rail)
ation D0 DIN rail mounting (Without DIN rail)
St
2
3 D3 For 3 stations Specify a length
…
159
Plug-in Connector Connecting Base SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported
Protective class
class # (Mark: )
160
Plug-in Connector Connecting Base
Type 10
Side Ported EX120
Type 11
Bottom Ported
SY3000/5000/7000 Series
RoHS
How to Order Manifolds
…
7 SY7000 R1 OMRON CompoBus/S 16 outputs
R2 (Positive common NPN) 8 outputs 08 8 stations
V CC-Link (Positive common NPN) 02 2 stations
w Type ZB∗1
Specified layout∗2
…
Positive common NPN
CompoNet™ (Up to 16 solenoids available)
10 Side ported ZBN∗1 Negative common PNP 16 16 stations
11 Bottom ported∗1 ∗1 The communication connector (for the ∗1 Double wiring: 2-position single, double,
∗1 The SY5000 manifold base is used for the opposite side) is not provided. Please order 3-position, and 4-position valves can be
bottom-ported SY3000. When ordering, it separately. used on all manifold stations.
refer to the “Plug-in Manifold Mixed ∗ Ensure a match with the common Use of a 2-position single solenoid will
Mounting Type” (from page 185). specification of the valve to be used. result in an unused control signal. If this is
not desired, order with a specified layout.
∗2 Specified layout: Indicate the wiring
specifications on the manifold specification
sheet. (Note that 2-position double,
3-position, and 4-position valves cannot be
used where single wiring has been
specified.)
How to Order Manifold Assembly ∗ This also includes the number of the blanking
plate assembly.
∗ Since R2 type SI unit has 8 outputs, note that
Example (SS5Y3-10S3V-) up to 8 solenoids can be accommodated.
Straight
C4 Ø4 — — N7 Ø 1/4"
Straight
C6 Ø6 N9 Ø 5/16" —
C8 Ø8 — N11 Ø 3/8" — — —
C10 Ø 10 — — — CM∗1 Straight port, mixed sizes
C12 Ø 12 — — — LN3 Ø 5/32" — — — —
Upward
CM∗1 Straight port, mixed sizes LN7 Ø 1/4" — — —
L4 Ø4 — — — LN9 Ø 5/16" — — — —
L6 Ø6 — — LN11 Ø 3/8" — — — —
Upward
Elbow∗2
L8 Ø8 — — — BN3 Ø 5/32" — — — —
Downward
B4 Ø4 — — — BN11 Ø 3/8" — — — —
Downward
P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 230).
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted
5 24 VDC
e Seal type !1 Type of mounting screw
0 Rubber seal
1 Metal seal o Light/surge voltage suppressor —
B
Round head combination screw
Hexagon socket head cap screw
and common specification K Round head combination screw (Drop prevention type)
Surge voltage Common
r Pilot type Symbol With light
suppressor specification
H Hexagon socket head cap screw (Drop prevention type)
∗ For “K” and “H,” the valve body cover has a
— Internal pilot R — drop prevention construction to stop the
Non-polar
R External pilot U mounting screws from falling out when the
S — Positive valve is removed for maintenance, etc.
∗ When ordering a valve individually, the
Z common
t Back pressure check valve NS — Negative
base gasket is not included.
(Built-in valve type) Since the base gasket is attached to the
NZ common
manifold, please order the base gasket
— None ∗ Select “R,” “U,” “S,” or “Z” for the valve when separately if it is needed for maintenance.
H Built-in the SI unit specification is positive common. Refer to page 222 for base gasket and
∗ Only the rubber seal type is available. A Select “R,” “U,” “NS,” or “NZ” for the valve mounting screw part numbers.
manifold installed type is available if a back when the SI unit specification is ZBN ∗ “B” and “H” cannot be selected for the
pressure check valve with a metal seal is (negative common). individual SUP/EXH spacer assembly,
required. Refer to page 236 for ordering ∗ For the non-polar type, be careful of surge interface regulator, or double check spacer
examples. However, it is not recommended voltage intrusion. assembly with residual pressure release
to use the built-in valve type and the manifold Refer to page 317 for details. valve.
installed type at the same time because it will ∗ Only “Z” and “NZ” types are available with a
reduce the flow. power saving circuit.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.
Protective class
class # (Mark: )
163
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
C2
U
SS5Y3-10S3- Stations D - C3, N1
C4, N3 (D)
B C6, N7
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 2
One-touch fitting
(Station 1)---(Station n) : Ø 3.2, Ø 1/8"
[1(P), 3/5(E) port]
: Ø 4, Ø 5/32"
Applicable tube O.D.: Ø 8, Ø 5/16"
: Ø 6, Ø 1/4"
1 P 1 P
10.6
13.6
63.1
56.6
61
3/5 E 2 B2 B2 B2 B2 B 3/5 E
40.2
21.6
4 A4 A4 A4 A4 A
18
11.8
39.7 15.5 P = 10.5 (17.8)
D side U side
Manual override∗1
DIN rail holding screw (L5) L1
(For DIN rail mounting) (
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
Light/surge voltage suppressor : Grey (For metal seal)
2(B) port side : Yellow
5.5
8
B A B A B A B A B A
92.6
14 A 14 A 14 A 14 A 14 A
64
35
83
6.2
60.5
40.9
12 B 12 B 12 B 12 B 12 B
M3
Terminal screw
16.1
4.6
4.6
1.7
)
(4.9)
C6: 3.6
N7: 7.4
4 x M4 mounting hole
(
∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10S3V-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 96.9 107.4 117.9 128.4 138.9 149.4 159.9 170.4 180.9 191.4 201.9 212.4 222.9 233.4 243.9
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5 189 199.5 210
L3 123 135.5 148 160.5 173 173 185.5 198 210.5 223 235.5 235.5 248 260.5 273
L4 112.5 125 137.5 150 162.5 162.5 175 187.5 200 212.5 225 225 237.5 250 262.5
L5 13 14 15 16 17 12 13 14 15 16 17 11.5 12.5 13.5 14.5
164
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C4, N3
SS5Y5-10S3- Stations D - C6, N7 (D)
B C8, N9
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 4, Ø 5/32"
One-touch fitting (Station 1)----------- (Station n) : Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 10, Ø 3/8"
1 P 1 P
73.2
2 B2 B2 B2 B2 B
56.6
61
14.1
33.4
3/5 E 3/5 E
29.1
4 A4 A4 A4 A4 A
12.4
8.7
mounting)
(Pitch)
11.8
44.2 18 P = 16 (20.5)
D side U side
Manual override∗1
(L5) L1
DIN rail holding screw
(For DIN rail mounting)
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
DIN rail Light/surge voltage suppressor : Grey (For metal seal) M3
2(B) port side : Yellow Terminal screw
8
5.5
6.2
BA BA BA BA BA
64
14 A 14 A 14 A 14 A 14 A
35
97.5
113.4
81.2
61.7
36.9
5.5
12 B 12 B 12 B 12 B 12 B
10.9
4.7
(5.9)
(8.3)
4 x M5 mounting hole
∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10S3V-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 116.7 132.7 148.7 164.7 180.7 196.7 212.7 228.7 244.7 260.7 276.7 292.7 308.7 324.7 340.7
L2 80 96 112 128 144 160 176 192 208 224 240 256 272 288 304
L3 148 160.5 173 198 210.5 223 248 260.5 273 285.5 310.5 323 335.5 348 373
L4 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5 275 300 312.5 325 337.5 362.5
L5 15.5 14 12 16.5 15 13 17.5 16 14 12.5 17 15 13.5 11.5 16
165
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
C6, N7
U
SS5Y7-10S3- Stations D - C8, N9
C10, N11 (D)
B C12
(Station 1) (Station n)
One-touch fitting
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 12, Ø 1/2"
2
82.7
1 P 1 P
2 B2 B2 B2 B2 B
56.6
61
11.1
3/5 E 3/5 E
35.2
8.7
31.6
4 A4 A4 A4 A4 A
14.2
mounting)
(14.3)
(Pitch)
47.7 20.5 P = 19
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
: Ø 12
D side U side
Manual override∗1
(L5) L1
DIN rail holding screw (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
(Light/surge voltage suppressor) : Grey (For metal seal)
2(B) port side: Yellow
(8)
(DIN rail)
B A B A B A B A B A
(35)
64
14 A 14 A 14 A 14 A 14 A
6.2
128.8
115
(5.5)
96.7
(77.1)
50.8
12 B 12 B 12 B 12 B 12 B
5.5
8.8
3.9
(6)
(9.3)
M3
(17.9)
∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10S3V-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
L1 129.4 148.4 167.4 186.4 205.4 224.4 243.4 262.4 281.4 300.4 319.4 338.4 357.4 376.4 395.4
L2 94 113 132 151 170 189 208 227 246 265 284 303 322 341 360
L3 160.5 173 198 210.5 235.5 248 273 285.5 310.5 335.5 348 373 385.5 410.5 423
L4 150 162.5 187.5 200 225 237.5 262.5 275 300 325 337.5 362.5 375 400 412.5
L5 15.5 12.5 15.5 12 15 12 15 11.5 14.5 17.5 14.5 17.5 14 17 14
166
Plug-in Connector Connecting Base
EX120
Type 12
Top Ported
SY3000/5000/7000 Series
RoHS
How to Order Manifolds
167
Plug-in Connector Connecting Base SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported
E: F:
Push-turn Slide locking
locking lever type
type
SY3000/5000/7000 Series
Type 11
Bottom Ported
…
Negative common (PNP) 4 5
∗ When “V” (CC-Link) is selected for the SI 16 16 stations
w Type unit, only symbol “2” or “4” (32 outputs) can 02 2 stations
Specified layout∗2
…
10 Side ported be selected. (Up to 32 solenoids available)
11 Bottom ported∗1 ∗ Ensure a match with the common specifica- 24 24 stations
∗1 The SY5000 manifold base is used for the tion of the valves to be used. In the case of the 16-output SI unit
bottom ported SY3000. When ordering,
Symbol Stations Note
refer to the “Plug-in Manifold Mixed
Mounting Type” (Refer to page 185). t Communication connector 02 2 stations
Double wiring∗1
…
— T-branch type
08 8 stations
e SI unit A Straight type
∗ The communication connector and power
02 2 stations
…
Specified layout∗2
…
0 Without SI unit
connector are shipped together with the (Up to 16 solenoids available)
Q DeviceNet™ manifold. The power connector is only availa-
16 16 stations
V CC-Link ble for the straight type. ∗1 Double wiring: 2-position single, double,
∗ Only the connector block assembly is ∗ When not selecting an SI unit, the symbol will 3-position, and 4-position valves can be
mounted for models without an SI unit. be “—.” used on all manifold stations.
Use of a 2-position single solenoid will result
in an unused control signal. If this is not
desired, order with a specified layout.
How to Order Manifold Assembly ∗2 Specified layout: Indicate the wiring
specifications on the manifold specification
sheet. (Note that 2-position double, 3-position,
Example (SS5Y3-10S8-) and 4-position valves cannot be used where
single wiring has been specified.)
2-position double (24 VDC) 3-position closed centre (24 VDC) ∗ This also includes the number of the blanking
SY3200-5U1 (1 set) SY3300-5U1 (1 set) plate assembly.
∗ For the product without the SI unit (S80),
2-position single (24 VDC)
note the maximum number of solenoids of
SY3100-5U1 (3 sets)
the SI unit that will be mounted. If the layout
is specified, indicate it on the manifold
ide
specification sheet.
Us
u P, E port entry, SUP/EXH block assembly
s
n
tio
ta
S
169
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Straight
C4 Ø4 — — N7 Ø 1/4"
Straight
C6 Ø6 N9 Ø 5/16" —
C8 Ø8 — N11 Ø 3/8" — — —
C10 Ø 10 — — — CM∗1 Straight port, mixed sizes
C12 Ø 12 — — — LN3 Ø 5/32" — — — —
Upward
CM∗1 Straight port, mixed sizes LN7 Ø 1/4" — — —
L4 Ø4 — — — LN9 Ø 5/16" — — — —
L6 Ø6 — — LN11 Ø 3/8" — — — —
Upward
Elbow∗2
L8 Ø8 — — — BN3 Ø 5/32" — — — —
Downward
B4 Ø4 — — — BN11 Ø 3/8" — — — —
Downward
P, E port size
Ø8 Ø 10 Ø 12 Ø 10 Ø 12
(One-touch fittings)
∗1 Indicate the sizes on the manifold specification sheet in the case of “CM” or “LM.”
The direction of P, E port fittings is the same as for the A, B port. If selecting “LM,” indicate it on the manifold specification sheet for the P, E port fitting
direction.
∗2 To avoid interference with the body or piping, select a downward elbow port when mounting the optional spacer assembly (pages 228 to 231).
···
BA — length of specified
D — — 24 For 24 stations stations.
DIN rail
A mounting
B —
∗ Enter the number of stations inside when it is larger than the number
of valve stations. (Refer to “DIN Rail Option” above.)
∗ Only direct mounting is available for Type 11 (Bottom ported).
∗ Refer to page 319 for the fixation of DIN rail mounting type manifold.
Protective class
class # (Mark: )
170
SY3000/5000/7000 Series
Refer to page 17 for valve
How to Order Valves (With mounting screw) specifications.
SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted
w Type of actuation
1
2-position
Single u Coil type E: F:
2 Double — Standard Push-turn Slide locking
3 Closed centre T With power-saving circuit (Continuous duty type) locking type
4 3-position Exhaust centre ∗ Be sure to select the power-saving circuit lever
5 Pressure centre type when the valve is to be continuously type
A∗1 N.C./N.C. energised for long periods of time.
B∗1
4-position
N.O./N.O. ∗ Be careful of the energising time when the
dual 3-port power-saving circuit is selected. Refer to
C∗1 N.C./N.O.
page 316 for details. ∗ Refer to page 36 for the safety slide locking
∗1 Only the rubber seal type is available for the manual override.
4-position dual 3-port valve.
i Rated voltage
5 24 VDC
!1 Type of mounting screw
e Seal type — Round head combination screw
0 Rubber seal B Hexagon socket head cap screw
1 Metal seal o Light/surge voltage suppressor K Round head combination screw (Drop prevention type)
and common specification H Hexagon socket head cap screw (Drop prevention type)
Surge voltage Common ∗ For “K” and “H,” the valve body cover has a
Symbol With light
r Pilot type R —
suppressor specification drop prevention construction to stop the
mounting screws from falling out when the
— Internal pilot Non-polar valve is removed for maintenance, etc.
U
R External pilot ∗ When ordering a valve individually, the
S — Positive base gasket is not included.
Z common Since the base gasket is attached to the
NS — Negative manifold, please order the base gasket
t Back pressure check valve NZ common separately if it is needed for maintenance.
Refer to page 222 for base gasket and
(Built-in valve type) ∗ Select “R,” “U,” “S,” or “Z” for the valve when
mounting screw part numbers.
the SI unit output polarity is positive common.
— None ∗ “B” and “H” cannot be selected for the
Select “R,” “U,” “NS,” or “NZ” for the valve
H Built-in
when the SI unit output polarity is negative
individual SUP/EXH spacer assembly,
∗ Only the rubber seal type is available. A interface regulator, or double check spacer
common.
assembly with residual pressure release
manifold installed type is available if a back ∗ Only “Z” and “NZ” are available with a
pressure check valve with a metal seal is valve.
power-saving circuit.
required. Refer to page 236 for ordering
examples. However, it is not recommended
to use the built-in valve type and the manifold
installed type at the same time because it will
reduce the flow.
∗ The built-in valve type back pressure check
valve is not available for the 3-position type
or the SY7000.
Protective class
class # (Mark: )
171
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
C2
U
SS5Y3-10S8- Stations D - C3, N1
C4, N3 (D)
B C6, N7
Communication connector
Shipped together with the manifold
One-touch fitting
[1(P), 3/5(E) port]
Applicable tubing O.D.: Ø 8, Ø 5/16"
One-touch fitting
(Station 1) (Station n)
[4(A), 2(B) port]
Ground terminal SI unit Applicable tubing O.D.: Ø 2
M3 : Ø 3.2, Ø 1/8"
: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
(Straight type: 55.2)
(65.4)
10.6
13.6
63.1
56.6
40.2
21.6
18
(7.5)
mounting)
75 15.5 P = 10.5 (17.8)
(11.8)
Power connector
Shipped together with the manifold
D side U side
(L5) L1 Manual override∗1
(8)
(5.5)
(35)
92.6
83
80.1
60.5
(40.9)
4.6
4.6
1.7
)
(4.9)
C6: 3.6
N7: 7.4
(Straight type: 12)
4 x M4 Mounting hole
(
(13.2)
L2 1.5 (Fitting for the type with P/E ports on the U and/or D sides)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)
∗1 Refer to page 177 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y3-10S8V2-05D-C6.”
∗ Refer to page 182 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13
L1 132.3 142.8 153.3 163.8 174.3 184.8 195.3 205.8 216.3 226.8 237.3 247.8
L2 63 73.5 84 94.5 105 115.5 126 136.5 147 157.5 168 178.5
L3 160.5 173 185.5 198 198 210.5 223 235.5 248 260.5 260.5 273
L4 150 162.5 175 187.5 187.5 200 212.5 225 237.5 250 250 262.5
L5 14 15 16 17 12 13 14 15 16 17 11.5 12.5
n: Stations 14 15 16 17 18 19 20 21 22 23 24
L1 258.3 268.8 279.3 289.8 300.3 310.8 321.3 331.8 342.3 352.8 363.3
L2 189 199.5 210 220.5 231 241.5 252 262.5 273 283.5 294
L3 285.5 298 310.5 323 335.5 335.5 348 360.5 373 385.5 398
L4 275 287.5 300 312.5 325 325 337.5 350 362.5 375 387.5
L5 13.5 14.5 15.5 16.5 17.5 12.5 13.5 14.5 15.5 16.5 17.5
172
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U C4, N3
SS5Y5-10S8- Stations D - C6, N7 (D)
B C8, N9
Communication connector
Shipped together with the manifold
One-touch fitting
[1(P), 3/5(E) port] One-touch fitting
Applicable tubing O.D.: Ø 10, Ø 3/8" [4(A), 2(B) port]
Applicable tubing O.D.: Ø 4, Ø 5/32"
(Station 1) (Station n) : Ø 6, Ø 1/4"
SI unit
: Ø 8, Ø 5/16"
Ground terminal
(Straight type: 55.2)
M3
14.1
73.2
(65.4)
56.6
12.4
8.7
33.4
29.1
(7.5)
mounting)
(11.8)
76.8 18 P = 16
Power connector
Shipped together with the manifold
D side U side
Manual override∗1
(L5) L1
DIN rail holding screw ( Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting)
4(A) port side: Blue (For rubber seal)
(Light/surge voltage suppressor) : Grey (For metal seal)
(DIN rail) 2(B) port side: Yellow
(8)
(5.5)
(Straight type: 92.1)
(35)
97.5
113.4
93.3
100.9
81.2
(61.7)
5.5
10.9
4.7
(5.9)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)
∗1 Refer to page 178 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y5-10S8V2-05D-C8.”
∗ Refer to page 183 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13
L1 149.3 165.3 181.3 197.3 213.3 229.3 245.3 261.3 277.3 293.3 309.3 325.3
L2 80 96 112 128 144 160 176 192 208 224 240 256
L3 173 198 210.5 223 248 260.5 273 285.5 310.5 323 335.5 360.5
L4 162.5 187.5 200 212.5 237.5 250 262.5 275 300 312.5 325 350
L5 12 16.5 14.5 13 17.5 15.5 14 12 16.5 15 13 17.5
n: Stations 14 15 16 17 18 19 20 21 22 23 24
L1 341.3 357.3 373.3 389.3 405.3 421.3 437.3 453.3 469.3 485.3 501.3
L2 272 288 304 320 336 352 368 384 400 416 432
L3 373 385.5 398 423 435.5 448 460.5 485.5 498 510.5 535.5
L4 362.5 375 387.5 412.5 425 437.5 450 475 487.5 500 525
L5 16 14 12.5 17 15 13.5 11.5 16 14.5 12.5 17
173
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
C6, N7
U
SS5Y7-10S8- Stations D - C8, N9
C10, N11 (D)
B C12
One-touch fitting
Communication connector [1(P), 3/5(E) port]
Shipped together with the manifold Applicable tubing O.D.: Ø 12, Ø 1/2"
(Station 1) (Station n)
SI unit
2
Ground terminal
(Straight type: 55.2)
M3
82.7
(65.4)
56.6
14.2
11.1
8.7
35.2
31.6
(Pitch) 21.7
(10)
mounting)
One-touch fitting
(14.3)
[4(A), 2(B) port]
Power connector Applicable tubing O.D.: Ø 6, Ø 1/4"
Shipped together with the manifold : Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
: Ø 12
D side U side
Manual override∗1
(L5) L1
DIN rail holding screw
( Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
(DIN rail) : Grey (For metal seal)
(Light/surge voltage suppressor)
2(B) port side: Yellow
(8)
(5.5)
(Straight type: 92.1)
(35)
93.3
128.8
115
116.3
96.7
(77.1)
5.5
8.8
3.9
(9.3)
(5.3) (L4)
(DIN rail mounting hole pitch: 12.5)
(L3)
∗1 Refer to page 179 for dimensions of the external pilot, silencer, elbow fittings, and slide locking manual override.
∗ These figures show the “SS5Y7-10S8V2-05D-C10.”
∗ Refer to page 184 for dimensions of A or B port top-ported type.
n: Stations 2 3 4 5 6 7 8 9 10 11 12 13
L1 163.5 182.5 201.5 220.5 239.5 258.5 277.5 296.5 315.5 334.5 353.5 372.5
L2 94 113 132 151 170 189 208 227 246 265 284 303
L3 198 210.5 235.5 248 273 285.5 310.5 323 348 360.5 385.5 398
L4 187.5 200 225 237.5 262.5 275 300 312.5 337.5 350 375 387.5
L5 17.5 14 17 14 17 13.5 16.5 13.5 16.5 13 16 13
n: Stations 14 15 16 17 18 19 20 21 22 23 24
L1 391.5 410.5 429.5 448.5 467.5 486.5 505.5 524.5 543.5 562.5 581.5
L2 322 341 360 379 398 417 436 455 474 493 512
L3 423 435.5 460.5 473 498 510.5 535.5 548 573 598 610.5
L4 412.5 425 450 462.5 487.5 500 525 537.5 562.5 587.5 600
L5 16 12.5 15.5 12.5 15.5 12 15 12 15 18 14.5
174
Plug-in Connector Connecting Base
EX180
Type 12
Top Ported
SY3000/5000/7000 Series
How to Order Manifolds
SS5Y 3 12S8 Q 05 U
Refer to pages 182 to 184 for the
dimensions of Type 12/Top-ported type. q w e r t y u i
q Series w SI unit t Valve stations
3 SY3000 0 Without SI unit In the case of the 32-output SI unit
5 SY5000 Q DeviceNet™ Symbol Stations Note
7 SY7000 V CC-Link 02 2 stations
Double wiring∗1
…
∗ Only the connector block assembly is
e SI unit output polarity, Number of outputs mounted for models without an SI unit. 16 16 stations
02 2 stations
32 outputs 16 outputs Specified layout∗2
r Communication connector
…
Without SI unit — (Up to 32 solenoids available)
Positive common (NPN) 2 3 — T-branch type 24 24 stations
Negative common (PNP) 4 5 A Straight type In the case of the 16-output SI unit
∗ When “V” (CC-Link) is selected for the SI unit, only ∗ The communication connector and power connector Symbol Stations Note
symbol “2” or “4” (32 outputs) can be selected. are shipped together with the manifold. The power 02 2 stations
∗ Ensure a match with the common specification of Double wiring∗1
…
connector is only available for the straight type.
the valves to be used. ∗ When not selecting an SI unit, the symbol will be 08 8 stations
“—.” 02 2 stations
Specified layout∗2
y P, E port entry, SUP/EXH block assembly
…
…
(Up to 16 solenoids available)
P, E port entry Internal pilot Internal pilot, Built-in silencer External pilot 16 16 stations
U side (2 to 10 stations) U C∗1 G ∗1 Double wiring: 2-position single, double,
D side (2 to 10 stations) D E∗1 H 3-position, and 4-position valves can be
Both sides (2 to 24 stations) B — J used on all manifold stations.
Use of a 2-position single solenoid will result
∗1 For SUP/EXH block assembly specifications, built-in silencer types will have P port entry stipulated.
∗ For built-in silencer type, P and E ports are available on U and D sides. 3/5(E) port is plugged. The in an unused control signal. If this is not
silencer exhaust port is located on the opposite side of P, E port entry. (Example: When the P, E desired, order with a specified layout.
port entry is D side, the silencer exhaust port is U side.) ∗2 Specified layout: Indicate the wiring
∗ When the built-in silencer type is used, keep the exhaust port from coming in direct contact with specifications on the manifold specification
water or other liquids. sheet. (Note that 2-position double, 3-position,
and 4-position valves cannot be used where
How to Order Manifold Assembly single wiring has been specified.)
∗ This also includes the number of the blanking
plate assembly.
Example (SS5Y3-12S8-) ∗ For the product without the SI unit (S80),
note the maximum number of solenoids of
2-position double (24 VDC) 3-position closed centre (24 VDC) the SI unit that will be mounted. If the layout
SY3230-5U1-C6 (1 set) SY3330-5U1-C6 (1 set) is specified, indicate it on the manifold
specification sheet.
···
175
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Refer to page 17 for valve
How to Order Valves (With mounting screw) specifications.
SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported
r Pilot type R —
Non-polar
!2 Thread type
U — Rc
— Internal pilot
S — Positive
F G
R External pilot
Z common N NPT
NS — Negative T NPTF
NZ common ∗ Only — is available for M5.
t Back pressure check valve ∗ Select “R,” “U,” “S,” or “Z” for the valve when
(Built-in valve type) the SI unit output polarity is positive common.
Select “R,” “U,” “NS,” or “NZ” for the valve
—
H
None
Built-in
when the SI unit output polarity is negative
common.
!3 Type of mounting screw
∗ Only the rubber seal type is available. A ∗ Only “Z” and “NZ” are available with a — Round head combination screw
manifold installed type is available if a back power-saving circuit. B Hexagon socket head cap screw
pressure check valve with a metal seal is K Round head combination screw (Drop prevention type)
required. Refer to page 236 for ordering
examples. However, it is not recommended !0 Manual override H Hexagon socket head cap screw (Drop prevention type)
∗ For “K” and “H,” the valve body cover has a
to use the built-in valve type and the manifold —: D: drop prevention construction to stop the
installed type at the same time because it will Non-locking Push-turn mounting screws from falling out when the
reduce the flow. push type locking slotted valve is removed for maintenance, etc.
∗ The built-in valve type back pressure check type ∗ When ordering a valve individually, the
valve is not available for the 3-position type base gasket is not included.
or the SY7000. Since the base gasket is attached to the
manifold, please order the base gasket
separately if it is needed for maintenance.
∗ “B” and “H” cannot be selected for the
E: F: individual SUP/EXH spacer assembly or
Push-turn Slide locking interface regulator.
locking lever type
type
Protective class
class # (Mark: )
176
SY3000/5000/7000 Series
Common Dimensions
Plug-in Type 10/Side Ported
SY3000 Series Connector Connecting Base External Pilot, Silencer, Elbow Fittings, Slide Locking Manual Override
U
SS5Y3-10- Stations D (S, R)- LB (Station 1)---(Station n)
B
manual override)
(Slide locking
1 P
(65.4)
68.8
63.1
56.6
(43.2)
3/5 E
)
)
L6 : 32.4
LN7 : 34.9
L6 : 43.4
LN7 : 45.9
(Pitch)
15.5 P= 10.5 (17.8)
(
(
D side U side
One-touch fitting 7.4 85.5
[PE: Pilot EXH port] (For 5 stations)
[X: External pilot port]
(7.4) (11.6) (73.2)
Applicable tube O.D.: Ø 4, Ø 5/32"
(Fitting for the type with P/E
ports on the U and/or D sides)
5.3
PE PE
LOCK
X X
3/5E B A B A B A B A B A 3/5E
14 A 14 A 14 A 14 A 14 A
(127.8)
40.9
58.5
FREE
1P 1P
12 B 12 B 12 B 12 B 12 B
11.6
6.9
1.7
17.3
27.6
35.2
LOCK
LOCK
FREE
FREE
B A B A B
14 A 14 A 14
(11.2)
FREE
4(A) port
12 B 12 B
3/5(E) port
2(B) port
1(P) port
Plug
(0.2)
3/5(E) port (7.2) (15)
177
Common Dimensions SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
SY5000 Series Connector Connecting Base External Pilot, Silencer, Elbow Fittings, Slide Locking Manual Override
U
SS5Y5-10- Stations D (S, R)- LB
B
(Station 1)----------- (Station n)
manual override)
(Slide locking
78.9
1 P
66.1
(59.8)
(54.3)
(39.3)
(38.8)
3/5 E
4 A4 A4 A4 A4 A
LOCK
PE PE
3/5 B A B A B A B A B A 3/5
26.9
14 A 14 A 14 A 14 A 14 A
113.4
E E
FREE
X X
1 1
(159.5)
61.7
52.8
P P
12 B 12 B 12 B 12 B 12 B
17.9
4.7
12.6
28.6
36.9
LOCK
3/5 BA BA
Silencer (Exhaust port) 14 A 14 A
X
1
(59.8)
P
(31.7)
12 B 12 B 12 B
LOCK
BA BA
14 A 14 A
FREE
LOCK
One-touch fitting
LOCK
LOCK
FREE
FREE
6.5
16.9
4(A) port
SY7000 Series Connector Connecting Base External Pilot, Silencer, Elbow Fittings, Slide Locking Manual Override
U
SS5Y7-10- Stations D (S, R)- LB External pilot for straight piping
B P, E port entry: D
(138.1)
(For 5 stations)
(20°)
(Station 1) (Station n)
LOCK
3/5E B A B A
85.8
(For Ø 10, Ø 3/8")
1 P
(For Ø 12)
69.7
(53.1)
(58)
FREE
(For Ø 12)
(For Ø 10, Ø 3/8")
(37.5)
(32.6)
(32.6)
3/5 E
1P
(74.2)
(23.5)
12 B 12 B
PE PE
LOCK
3/5E B A B A B A B A B A 3/5E
14 A 14 A 14 A 14 A 14 A
49.4
128.8
FREE
(175.6)
1P 1P
(77.1)
X X
45.4
12 B 12 B 12 B 12 B 12 B
15.6
3.9
34.6
37.6
16.6
LOCK
FREE
FREE
LOCK
B A B A
14 A 14 A
FREE
12 B 12 B
U
SS5Y5-11- Stations D
B External pilot
120.5 (118.2) P, E port entry: D
(For 5 stations) (For 5 stations)
(20°)
(Pitch)
18 P = 16 (20.5)
4.7
LOCK
PE
31.8
3/5 B A B A
39.7
14 A 14 A
3/5 E 3/5 E
2 B2 B2 B2 B2 B E
FREE
X
18
15 1
(59.8)
1 P 1 P P
4 A4 A4 A4 A4 A
(31.7)
12 B 12 B 12 B
LOCK
BA BA
14 A 14 A
8.7
4.7
FREE
(9.5)
(12.9)
12 B 12 B 12 B
(Fitting for the type with P/E
ports on the U and/or D sides)
Plug
D side U side
L2 1.5 Manual override
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
: Grey (For metal seal)
2(B) port side : Yellow
4 x M5 mounting hole
LOCK
BA BA BA BA B A
14 A 14 A 14 A 14 A 14 A
97.5
FREE
5.5
12 B 12 B 12 B 12 B 12 B
10.9
Lead wire : p. 83
Circular connector : p. 93
EX500 (128 points) : p. 103
EX500 (64 points) : p. 109
EX600 : pp. 120, 121
L2 EX250 : p. 138
4 x M5 Mounting hole EX260 : p. 149
4 x Ø 5.5 EX126 : p. 157
EX120 : p. 165
180
SY3000/5000/7000 Series
Plug-in Type 11/Bottom Ported
U
SS5Y7-11- Stations D External pilot
B
P, E port entry: D (138.1)
(Pitch) (For 5 stations)
40.1 (20°)
39.5 20.5 P = 19 (21.7)
3.9
39.9
48.7
PE
LOCK
3/5 E 3/5 E
3/5E B A B A
2 B2 B2 B2 B2 B 14 A 14 A
21
19.5
FREE
4 A4 A4 A4 A4 A
1 P 1 P
1P
(74.2)
Fitting dimensions for panel mounting 12 B 12 B
(23.5)
Refer to panel fitting dimensions
for details. X
P, E port entry: D
Silencer (Exhaust port)
2
LOCK
8.7
B A B A
14 A 14 A
FREE
9.1
(12)
(14.5)
(23.9)
(A, B port: Ø 12) (Fitting for the type with P/E Plug
12 B 12 B
ports on the U and/or D sides)
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
115
FREE
4 x M5 mounting hole
12 B 12 B 12 B 12 B 12 B
5.5
8.8
Lead wire : p. 84
Circular connector : p. 94
EX500 (128 points) : p. 104
EX500 (64 points) : p. 110
EX600 : pp. 122, 123
EX250 : p. 139
4 x M5 EX260 : p. 150
L2 Mounting hole EX126 : p. 158
4 x Ø 5.5 EX120 : p. 166
181
Common Dimensions SY3000/5000/7000 Series
Plug-in Type 12/Top Ported
U
SS5Y3-12- Stations D (R)
B
(Station 1)---(Station n)
)C6: 77.3
N7: 81.1
1 P 1 P
(73.8)
3/5 E 2 B2 B2 B2 B2 B 3/5 E
(
4 A4 A4 A4 A4 A
D side U side
89.3
(For 5 stations) Light/surge voltage suppressor
PE PE
LOCK
X X
3/5E B A B A B A B A B A 3/5E
92.6
4A 4A 4A 4A 4A
15
11
60.5
58.5
FREE
40.9
1P 1P
31.8
30.2
2B 2B 2B 2B 2B
1.7
One-touch fitting
(A/B port, side ported)
M5 x 0.8
[4(A), 2(B) port] One-touch fitting
(
182
SY3000/5000/7000 Series
Plug-in Type 12/Top Ported
U
SS5Y5-12- Stations D (R)
B
(Station 1)----------- (Station n)
(91.3)
76.9
1 P 1 P
(69.7)
2 B2 B2 B2 B2 B
3/5 E 3/5 E
4 A4 A4 A4 A4 A
D side U side
Light/surge voltage suppressor
123.6
(For 5 stations)
PE PE
LOCK
BA BA BA BA B A
3/5 3/5
26.9
4A 4A 4A 4A 4A
113.4
116.7
E E
FREE
X X
1 1
81.2
61.7
01 : 16.2
C : 14.5
52.8
P P
47.3
39.5
2B 2B 2B 2B 2B
2.7
183
Common Dimensions SY3000/5000/7000 Series
Plug-in Type 12/Top Ported
U
SS5Y7-12- Stations D (R)
B
(Station 1) (Station n)
(112.1)
(100.3)
88.8
1 P 1 P
(75.1)
2 B2 B2 B2 B2 B
3/5 E 3/5 E
8.7
4 A4 A4 A4 A4 A
mounting)
(14.3)
One-touch fitting
(External pilot) D side U side
[PE: Pilot EXH port] (Light/surge voltage suppressor)
[X: External pilot port]
144.3 Manual override
Applicable tube O.D.: Ø 6, Ø 1/4"
(Pitch)
26.1 P = 19
(For 5 stations)
(17.1)
(
Push-turn locking slotted type:
Press, then rotate it. ) 85.8
(Slide locking manual override)
4(A) port side: Blue (For rubber seal)
6.2 (6.2) : Grey (For metal seal) (69.5)
2(B) port side: Yellow
PE PE
LOCK
3/5E B A B A B A B A B A 3/5E
4A 4A 4A 4A 4A
(49.4)
21
128.8
133.2
FREE
22.6
96.7
1P 1P
(77.1)
X X
59.9
(45.5)
46.4
2B 2B 2B 2B 2B
2.4
184
Plug-in Connector Connecting Base: Plug-in Manifold Mixed Mounting Type
D-sub Connector (IP40/67) Flat Ribbon Cable Terminal Block Box/Spring Type (IP67)
Type 10 Terminal Block Box (IP67) Lead Wire (IP67) Circular Connector (IP67) EX500 (IP67)
Side Ported EX600 (IP67) EX245 (IP65) EX250 (IP67) EX260 (IP67) EX126 (IP67) EX120 EX180
Type 11
Bottom Ported
SY3000/5000 Series ®
The SY3000 can be mounted onto the ∗ Refer to the connector type.
SY5000 size manifold. How to Order Manifolds
Refer to page 174 for the
dimensions of Type 11/
Bottom-ported type.
SS5Y5 M 10 F 1 05 U C 8 6
Mixed Mounting Type
It is possible to mount the SY3000 size valves on all stations.
q w e r t y u i o !0
In this case, there is no need to fill in part i in the order code.
However, the manifold block width should be 12.5 mm.
U U side (2 to 10 stations)
P 26 pins 43
D D side (2 to 10 stations)
PG Flat ribbon cable 20 pins
B Both sides (2 to 24 stations)
PH 10 pins
∗ Refer to page 115 for the EX600 and u on
TC Terminal block box (Spring type) 61
page 127 for the EX250.
T Terminal block box 69
L1 34 cores
L2 Lead wire 17 cores 79 u Fitting type: One-touch fitting
L3 9 cores Symbol A, B port
M Circular connector 89 C Straight
EX500 Gateway L Metric size Upward∗2
Elbow
Decentralised B Downward∗2
S System 2
99
N Straight
(128 points) LN Inch size Upward∗2
Elbow
EX500 Gateway BN Downward∗2
Decentralised CM∗1 Straight
S 105 Mixed sizes
System LM∗1 Elbow (Including upward and downward piping)∗2
Serial (64 points)
transmission ∗1 Select CM or LM if mixed port sizes are to be used for each series.
S6 EX600 115 (For example, if mixed sizes, such as C6 and C8, are to be used for
SA EX245 127 the SY5000 series) In such cases, indicate the sizes on the manifold
S EX250 133 specification sheet.
The direction of P, E port fittings is the same as for the A, B port. If
S EX260 141
selecting “LM,” indicate it on the manifold specification sheet for the P,
S4∗1 EX126 153 E port fitting direction.
S3∗1 EX120 161 ∗2 To avoid interference with the body or piping, select a downward
S8 EX180 169 elbow port when mounting the optional spacer assembly (pages 228
∗1 EX126, EX120 are not yet UL-compliant. to 230). Elbow fittings are not available for Type 11 (Bottom ported).
∗ Refer to the pages shown in the table above for details. ∗ Elbow fittings: Ø 2, Ø 3.2, and Ø 1.8" are not available for the SY3000
series. Ø 2, Ø 3.2, Ø 1.8", and Ø 5/32" are not available for the SY5000
e series.
…
8 Ø8 9 Ø 5/16" [The SY5000 valve is now at a mountable length
— For all stations of SY3000 — For all stations of SY3000 D24 For 24 stations (manifold block length of 16 mm).]
∗ No symbol needs to be specified when fitting type “CM” or “LM” is ∗ Only direct mounting is available for the type 11 bottom-ported type.
selected. ∗ Refer to page 192 to determine the L3 using “Calculation formula” for
the DIN rail length.
∗ Refer to page 319 for the fixation of DIN rail mounting type manifold.
o SY3000: A, B port size
(Metric/One-touch fitting) (Inch/One-touch fitting)
Symbol Port size Symbol Port size
2 Ø2 1 Ø 1/8"
3 Ø 3.2 3 Ø 5/32"
4 Ø4 7 Ø 1/4"
6 Ø6 9 Ø 5/16"∗1
8 Ø 8∗1
∗1 The valve pitch is the same as that of the SY5000.
∗ No symbol needs to be specified when fitting type “CM” or “LM” is
selected.
Example (SS5Y5-M10F1-)
2-position double
2-position double SY3200-5U1 (2 sets)
SY5200-5U1 (3 sets) Manifold base (5 stations)
SS5Y5-M10F1-05D-C86
ide
Us
o ns
ati
St
3
2
1
e
D sid
SS5Y5-M10F1-05D-C86 ··· 1 set (Type M10 5-station manifold base part no.)
∗SY5200-5U1 ····················· 3 sets (2-position double part no.)
∗SY3200-5U1 ····················· 2 sets (2-position double part no.)
The asterisk denotes the symbol for the assembly.
Prefix it to the part numbers of the valve, etc.
• For the valve arrangement, the valve closest to the D side is considered the 1st station.
• Under the manifold part number, state the valves to be mounted in order starting
with the 1st station as shown in the figure above. If the arrangement becomes too
complicated, specify the details on a manifold specification sheet.
∗ When mixing top-ported configurations, select from those listed on page 198.
In such cases, use caution as there is also output on the A and B ports on
the base side.
Protective class
Specify on the manifold specification sheet if plugs are required for the A and
B ports on the base side.
class # (Mark: )
186
SY3000/5000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted
1 Single
2
2-position
Double u Coil type E: F:
3 Closed centre — Standard
Push-turn Slide locking
4 3-position Exhaust centre T With power saving circuit (Continuous duty type) locking type
5 Pressure centre ∗ Be sure to select the power saving circuit lever
A∗1 N.C./N.C. type if the valve is to be continuously type
4-position energised for long periods of time.
B∗1 dual 3-port
N.O./N.O.
C∗1 N.C./N.O. ∗ Be careful of the energising time when the
power saving circuit is selected. Refer to
∗1 Only the rubber seal type is available for the page 316 for details. ∗ Refer to page 36 for the safety slide locking
4-position dual 3-port valve. manual override.
i Rated voltage
e Seal type 5 24 VDC !1 Type of mounting screw
0 Rubber seal 6 12 VDC
— Round head combination screw
1 Metal seal ∗ Only 24 VDC is available for the serial B Hexagon socket head cap screw
transmission type.
K Round head combination screw (Drop prevention type)
H Hexagon socket head cap screw (Drop prevention type)
r Pilot type o Light/surge voltage suppressor ∗ For “K” and “H,” the valve body cover has a
drop prevention construction to stop the
— Internal pilot and common specification mounting screws from falling out when the
R External pilot
Symbol With light
Surge voltage Common valve is removed for maintenance, etc.
suppressor specification ∗ When ordering a valve individually, the
— — — base gasket is not included.
R — Non-polar Since the base gasket is attached to the
t Back pressure check valve U
manifold, please order the base gasket
(Built-in valve type) separately if it is needed for maintenance.
S — Positive Refer to page 222 for base gasket and
— None
Z common mounting screw part numbers.
H Built-in NS — Negative ∗ “B” and “H” cannot be selected for the
∗ Only the rubber seal type is available. A NZ common individual SUP/EXH spacer assembly,
manifold installed type is available if a back ∗ “—” is not available for the SI unit manifold. interface regulator, or double check spacer
pressure check valve with a metal seal is ∗ For the non-polar type, be careful of surge assembly with residual pressure release
required. Refer to page 236 for ordering voltage intrusion. valve.
examples. However, it is not recommended Refer to page 317 for details.
to use the built-in valve type and the manifold ∗ Only “Z” and “NZ” types are available with a
installed type at the same time because it will power saving circuit. Select a valve which is
reduce the flow. suited to the SI unit output polarity or SI unit
∗ The built-in valve type back pressure check specification when the SI unit is selected.
valve is not available for the 3-position type. Refer to the pages below for details.
EX500: pp. 101, 107 EX600: p. 117
EX245: p. 127 EX250: p. 136
EX260: p. 144 EX126: p. 155
EX120: p. 163 EX180: p. 171
Protective class
class # (Mark: )
187
188
Plug-in Connector Connecting Base: Plug-in Manifold Mixed Mounting Type
D-sub Connector (IP40/67) Flat Ribbon Cable Terminal Block Box/Spring Type (IP67)
Type 10 Terminal Block Box (IP67) Lead Wire (IP67) Circular Connector (IP67) EX500 (IP67)
Side Ported EX600 (IP67) EX250 (IP67) EX260 (IP67) EX126 (IP67) EX120
Type 11
Bottom Ported
SY5000/7000 Series ®
The SY5000 can be mounted onto the ∗ Refer to the connector type.
SY7000 size manifold. How to Order Manifolds
Refer to page 195 for the
dimensions of Type 11/
Bottom-ported type.
SS5Y7 M 10 F 1 05 U C 10 8
Mixed Mounting Type
It is possible to mount the SY5000 size valves on all stations.
q w e r t y u i o !0
In this case, there is no need to fill in part i in the order code.
However, the manifold block width should be 19 mm.
U U side (2 to 10 stations)
P 26 pins 43
D D side (2 to 10 stations)
PG Flat ribbon cable 20 pins
B Both sides (2 to 24 stations)
PH 10 pins
∗ Refer to page 115 for the EX600 and u on
TC Terminal block box (Spring type) 61
page 127 for the EX250.
T Terminal block box 69
L1 34 cores
L2 Lead wire 17 cores 79 u Fitting type: One-touch fitting
L3 9 cores Symbol A, B port
M Circular connector 89 C Straight
EX500 Gateway L Metric size Upward∗2
Elbow
Decentralised B Downward∗2
S System 2
99
N Straight
(128 points) LN Inch size Upward∗2
Elbow
EX500 Gateway BN Downward∗2
Decentralised CM∗1 Straight
S Serial 105 Mixed sizes
System LM∗1 Elbow (Including upward and downward piping)∗2
transmission (64 points) ∗1 Select CM or LM if mixed port sizes are to be used for each series.
S6 EX600 115 (For example, if mixed sizes, such as C6 and C8, are to be used for
S EX250 133 the SY5000 series) In such cases, indicate the sizes on the manifold
S EX260 141 specification sheet.
The direction of P, E port fittings is the same as for the A, B port. If
S4∗1 EX126 153
selecting “LM,” indicate it on the manifold specification sheet for the P,
S3∗1 EX120 161 E port fitting direction.
∗1 EX126, EX120 are not yet UL-compliant. ∗2 To avoid interference with the body or piping, select a downward
∗ Refer to the pages shown in the table above elbow port when mounting the optional spacer assembly (pages 228
for details. to 230). Elbow fittings are not available for Type 11 (Bottom ported).
∗ Elbow fittings: Ø 1/4" and Ø 5/16" are not available.
e
• With Lead wire
Lead wire length
1 0.6 m
2 1.5 m
3 3m
189
Plug-in Connector Connecting Base SY5000/7000 Series
…
BA — than the total length
10 Ø 10 11 Ø 3/8"
12 Ø 12 — For all stations of SY5000 D — — 24 For 24 stations of specified stations.
DIN rail
— For all stations of SY5000 A mounting
∗ No symbol needs to be specified when fitting type “CM” or “LM” is B —
selected. ∗ Enter the number of stations inside when it is larger than the number
of valve stations. (Refer to “DIN Rail Option” above.)
∗
o SY5000: A, B port size ∗
Only direct mounting is available for the type 11 bottom-ported type.
Refer to page 192 to determine the L3 using “Calculation formula” for
(Metric/One-touch fitting) (Inch/One-touch fitting) the DIN rail length. (For the SY3000 and SY5000 mixed mounting type)
Symbol Port size Symbol Port size ∗ The manifold block width is 19 mm for both the SY5000 and SY7000
6 Ø6 7 Ø 1/4" sizes.
∗ Refer to page 319 for the fixation of DIN rail mounting type manifold.
8 Ø8 9 Ø 5/16"
10 Ø 10 11 Ø 3/8"
12 Ø 12
∗ The valve pitch is 19 mm, the same as that of the SY7000.
∗ No symbol needs to be specified when fitting type “CM” or “LM” is
selected.
Example (SS5Y7-M10F1-)
2-position double
SY5200-5U1 (2 sets)
2-position double
SY7200-5U1 (3 sets) Manifold base (5 stations)
SS5Y7-M10F1-05D-C128
ide
Us
s
at ion
St
3
2
1
ide
Ds
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 7 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted
1 Single
2
2-position
Double u Coil type E: F:
3 Closed centre — Standard
Push-turn Slide locking
4 3-position Exhaust centre T With power saving circuit (Continuous duty type) locking type
5 Pressure centre ∗ Be sure to select the power saving circuit lever
A∗1 N.C./N.C. type if the valve is to be continuously type
4-position energised for long periods of time.
B∗1 dual 3-port
N.O./N.O.
C∗1 N.C./N.O. ∗ Be careful of the energising time when the
power saving circuit is selected. Refer to
∗1 Only the rubber seal type is available for the page 316 for details. ∗ Refer to page 36 for the safety slide locking
4-position dual 3-port valve. manual override.
i Rated voltage
e Seal type 5 24 VDC !1 Type of mounting screw
0 Rubber seal 6 12 VDC
— Round head combination screw
1 Metal seal ∗ Only 24 VDC is available for the serial B Hexagon socket head cap screw
transmission type.
K Round head combination screw (Drop prevention type)
H Hexagon socket head cap screw (Drop prevention type)
r Pilot type o Light/surge voltage suppressor ∗ For “K” and “H,” the valve body cover has a
drop prevention construction to stop the
— Internal pilot and common specification mounting screws from falling out when the
R External pilot
Symbol With light
Surge voltage Common valve is removed for maintenance, etc.
suppressor specification ∗ When ordering a valve individually, the
— — — base gasket is not included.
R — Non-polar Since the base gasket is attached to the
t Back pressure check valve U
manifold, please order the base gasket
(Built-in valve type) separately if it is needed for maintenance.
S — Positive Refer to page 222 for base gasket and
— None
Z common mounting screw part numbers.
H Built-in NS — Negative ∗ “B” and “H” cannot be selected for the
∗ Only the rubber seal type is available. A NZ common individual SUP/EXH spacer assembly,
manifold installed type is available if a back ∗ “—” is not available for the SI unit manifold. interface regulator, or double check spacer
pressure check valve with a metal seal is ∗ For the non-polar type, be careful of surge assembly with residual pressure release
required. Refer to page 236 for ordering voltage intrusion. Refer to page 317 for valve.
examples. However, it is not recommended details.
to use the built-in valve type and the manifold ∗ Only “Z” and “NZ” types are available with a
installed type at the same time because it will power saving circuit. Select a valve which is
reduce the flow. suited to the SI unit output polarity or SI unit
∗ The built-in valve type back pressure check specification when the SI unit is selected.
valve is not available for the 3-position type Refer to the pages below for details.
or the SY7000. EX500: pp. 101, 107 EX600: p. 117
EX250: p. 136 EX260: p. 144
EX126: p. 155 EX120: p. 163
Protective class
class # (Mark: )
191
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U
SS5Y5-M10- Stations D
B
One-touch fitting
(Station 1)--------- (Station n) [4(A), 2(B) port]
One-touch fitting
Applicable tube O.D.: Ø 2
[4(A), 2(B) port] Compatible with mixed : Ø 3.2, Ø 1/8"
Applicable tube O.D.: Ø 4, Ø 5/32" mounting type: Ø 8, Ø 5/16" : Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
(SY3000)
(SY3000)
11.1
31.5
78.9
1 P 1 P
73.2
2 B2 B2 B2 B2 B
8.7
3/5 3/5
33.4
E 4 A4 A4 A E
4 A4 A
12.4
14.1
(SY5000 and SY3000: Ø 8, Ø 5/16")
29.1
(SY5000 and SY3000: Ø 8, Ø 5/16")
(11.8)
(For DIN rail mounting)
(7.5)
One-touch fitting 35.9 18 (20.5)
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 10, Ø 3/8" ( Pitch
SY5000 )
of
( Pitch
SY3000 )
of Calculation formula for dimensions with
D-sub connector <IP40> and Flat ribbon
P = 16 P = 12.5 cable
( Pitch
Ø 5/16" )
of SY3000: Ø 8, One-touch fitting
[4(A), 2(B)port]
L1 = 12.5 x n1 + 16 x n2 + 76.4
L2 = 12.5 x n1 + 16 x n2 + 48
P = 16 Applicable tube O.D.: Ø 8, Ø 5/16" M = (L1 + 6.1)/12.5 + 1 Decimal fractions are truncated.
L3 = 12.5 x M + 23
L4 = L3 – 10.5
L5 = (L3 – L1 + 6.1)/2
n1: Number of valve stations of the SY3000
D side U side n2: Number of valve stations of the SY5000
(L5) Manual override (Including the stations of the SY3000: Ø 8,
L1
Ø 5/16")
DIN rail holding screw (
Push-turn locking slotted type:
Press, then rotate it. )
(For DIN rail mounting) 4(A) port side : Blue (For rubber seal)
DIN rail Light/surge voltage suppressor : Grey (For metal seal)
2(B) port side : Yellow
8
5.5
LOCK
B A B A B A B A B A
35
14 A 14 A 14 A 14 A 14 A
97.5
113.4
FREE
81.2
12 B 12 B
(61.7)
61.7
5.5
12 B 12 B
10.9
4 x M5
4.7
(5.9)
(8.3)
mounting hole
21.9 L2 1.5 (Fitting for the type with P
and E ports on both sides)
5.3 (L4)
(DIN rail mounting hole pitch: 12.5)
(L3) ∗ Refer to pages 177 and 178 for
dimensions of the external pilot,
built-in silencer, and elbow fittings.
Calculation formula for dimensions with D-sub
connector <IP67>, Terminal block box (Spring type),
Terminal block box, Lead wire, Circular connector,
EX500/600/250/260/126/120 serial transmission
L1 = 12.5 x n1 + 16 x n2 + a + b x n3 Coefficient a b c
L2 = 12.5 x n1 + 16 x n2 x 48 D-sub connector <IP67> 90.5 — —
M = L1/12.5 + 1 Decimal fractions are truncated.
L3 = 12.5 x M + 23 Terminal block box (Spring type) 128 — —
L4 = L3 – 10.5 Terminal block box or Serial transmission: EX126 149.3 — —
L5 = (L3 – L1)/2 Lead wire or Circular connector 97 — —
L6 = b x n3 + c
EX500 Gateway Decentralised System 2 (128 points) 88.7 — —
n1: Number of valve stations of the SY3000
n2: Number of valve stations of the SY5000 EX500 Gateway Decentralised System (64 points) 88.5 — —
(Including the stations of the SY3000: Ø 8, Ø 5/16") Serial transmission: EX600 (M12 connector) 141.5 47 81.5
n3: Number of I/O units or input block stations
Serial transmission: EX600 (7/8 inch connector) 158 47 81.5
∗ Refer to pages 120 and 121 for dimensions of the
EX600 serial transmission with I/O unit and page Serial transmission: EX250 141.5 21 81.5
132 for the EX250 serial transmission with input Serial transmission: EX260 88.7 — —
block when L6, b, and c are used for the
calculation formula. Serial transmission: EX120 84.7 — —
192
SY3000/5000/7000 Series
Plug-in Type 10/Side Ported
U
SS5Y7-M10- Stations D
B One-touch fitting (For SY5000)
[4(A), 2(B) port]
Applicable tube O.D.: Ø 6 ,Ø 1/4"
(Station 1) (Station n)
: Ø 8 ,Ø 5/16"
: Ø 10,Ø 3/8"
: Ø 12
manual override)
(Slide locking
85.8
82.7
1 P 1 P
2 B2 B2 B2 B2 B
11.1
3/5 E 3/5 E
8.7
35.2
31.6
4 A4 A4 A4 A4 A
14.2
(10)
(14.3)
One-touch fitting 39.5 20.5
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 12, Ø 1/2" (Pitch) (Pitch)
P = 19 P = 19
(L5) L1 (
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
DIN rail holding screw : Grey (For metal seal)
(For DIN rail mounting) 2(B) port side : Yellow
Light/surge voltage suppressor (8)
(DIN rail)
LOCK
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
128.8
115
SY5000: 95.7
SY7000: 96.7
FREE
(5.5)
(35)
(77.1)
12 B 12 B 12 B
12 B 12 B
5.5
8.8
3.9
(6)
(9.3)
(17.9)
∗ Refer to page 179 for dimensions of the external pilot and built-in silencer.
∗ Refer to the pages below for L1, L2, L3, L4 dimensions and other dimensions that are not specified in each wiring specification.
D-sub connector <IP40> : p. 48
D-sub connector <IP67> : p. 51
Flat ribbon cable : p. 54
Terminal block box (Spring type) : p. 65
Terminal block box : p. 74
Lead wire : p. 84
Circular connector : p. 94
EX500 (128 points) : p. 104
EX500 (64 points) : p. 110
EX600 : pp. 122, 123
EX250 : p. 139
EX260 : p. 150
EX126 : p. 158
EX120 : p. 166
193
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 11/Bottom Ported
U
SS5Y5-M11- Stations D (Pitch of SY3000: Ø 8, Ø 5/16")
P=16
B
(Pitch of SY5000) Panel/fitting dimensions
(Pitch of SY3000)
P=16
P=12.5
7
4.7
35.9 18 (20.5)
)
Ø 8, Ø 5/16"
SY5000 and
60
31.8
SY3000:
(SY3000)
39.7
97.5
49.6
3/5 E 3/5 E
2 B2 B2 B
) (
18
(
1 P 1 P
Refer to panel fitting dimensions 4 A4 A4 A
(SY3000)
4 A4 A
Ø 8, Ø 5/16"
SY5000 and
for details.
SY3000:
L2
11
4 x M5 mounting hole
15
4 x Ø 5.5
One-touch fitting
(
[1(P), 3/5(E) port]
Applicable tube O.D.: Ø 10, Ø 3/8" One-touch fitting
[4(A), 2(B) port]
One-touch fitting Applicable tube O.D.: Ø 2
[4(A), 2(B) port] One-touch fitting : Ø 3.2, Ø 1/8"
Applicable tube O.D.: Ø 4, Ø 5/32" [4(A), 2(B) port] : Ø 4, Ø 5/32"
: Ø 6, Ø 1/4" Applicable tube O.D.: Ø 8, Ø 5/16" : Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
(Station 1)--------- (Station n)
Compatible with mixed
mounting type: Ø 8, Ø 5/16" Calculation formula for dimensions
SY3000
L1 = 12.5 x n1 + 16 x n2 + a + b x n3
manual override)
(Slide locking
L2 = 12.5 x n1 + 16 x n2 + 48
L6 = b x n3 + c
78.9
73.2
(7.3)
(9.5)
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal) 4 x M5 mounting hole
: Grey (For metal seal)
2(B) port side : Yellow
LOCK
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
97.5
113.4
FREE
81.2
12 B 12 B
5.5
12 B 12 B
10.9
21.9 L2 1.5
Coefficient a b c
D-sub connector <IP40> or Flat ribbon cable 76.4 — —
D-sub connector <IP67> 90.5 — —
Terminal block box (Spring type) 128 — —
Terminal block box or Serial transmission: EX126 149.3 — —
Lead wire or Circular connector 97 — —
EX500 Gateway Decentralised System 2 (128 points) 88.7 — — ∗ Refer to page 180 for dimensions of the external pilot
EX500 Gateway Decentralised System (64 points) 88.5 — — and built-in silencer.
Serial transmission: EX600 (M12 connector) 141.5 47 81.5
Serial transmission: EX600 (7/8 inch connector) 158 47 81.5
Serial transmission: EX250 141.5 21 81.5
Serial transmission: EX260 88.7 — —
Serial transmission: EX120 84.7 — —
194
SY3000/5000/7000 Series
Plug-in Type 11/Bottom Ported
U
SS5Y7-M11- Stations D ∗ Refer to page 181 for dimensions of the external pilot and built-in silencer.
B ∗ Refer to the pages below for L1, L2 dimensions and other dimensions
that are not specified in each wiring specification.
Dimensions of Type 11/Bottom ported: p. 181
D-sub connector <IP40> : p. 48
D-sub connector <IP67> : p. 51
Flat ribbon cable : p. 54
Terminal block box (Spring type) : p. 65
(Pitch) (Pitch)
Terminal block box : p. 74
39.5 20.5 P = 19 P = 19 (21.7)
Lead wire : p. 84
3.9
Circular connector : p. 94
EX500 (128 points) : p. 104
EX500 (64 points) : p. 110
39.9
48.7
3/5 E 3/5 E
EX600 : pp. 122, 123
2 B2 B2 B2 B2 B
EX250 : p. 139
EX260 : p. 150
21
19.5
4 A4 A4 A4 A4 A
EX126 : p. 158
1 P 1 P
EX120 : p. 166
16
(Station 1) (Station n)
60
(Slide locking manual override)
115
2
85.8
82.7
56.6
9.1
L2 4 x M5 mounting hole
4 x Ø 5.5
(12)
(14.5)
(23.9)
D side U side
L1
Manual override
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
128.8
115
SY5000: 95.7
SY7000: 96.7
FREE
12 B 12 B 12 B
12 B 12 B
5.5
8.8
195
196
Plug-in Connector Connecting Base: Plug-in Manifold Mixed Mounting Type
D-sub Connector (IP40/67) Flat Ribbon Cable Terminal Block Box/Spring Type (IP67)
Terminal Block Box (IP67) Lead Wire (IP67) Circular Connector (IP67) EX500 (IP67)
EX600 (IP67) EX245 (IP65) EX250 (IP67) EX260 (IP67) EX126 (IP67) EX120 EX180
Type 12
Top Ported
SY3000/5000/7000 Series
For the SY5000 series, the SY5000 and the SY3000
can be mounted on the same manifold.
For the SY7000 series, the SY7000 and the SY5000
®
S EX260 141
valve is now at a mountable
on the number of stations. Refer
S4∗1
…
SS5Y5-M12F1-05D ··· 1 set (Type M12 5-station manifold base part no.)
∗SY5230-5U1-C8 ········ 3 sets (2-position double part no.)
∗SY3230-5U1-C6 ········ 2 sets (2-position double part no.)
ide The asterisk denotes the symbol for the assembly.
Us Prefix it to the part numbers of the valve, etc.
ns
a tio
St • For the valve arrangement, the valve closest to the D side is considered the 1st station.
3
2 • Under the manifold part number, state the valves to be mounted in order starting
1 with the 1st station as shown in the figure above. If the arrangement becomes too
ide
Ds
complicated, specify the details on a manifold specification sheet.
197
Plug-in Connector Connecting Base SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported
Protective class
class # (Mark: )
198
SY3000/5000/7000 Series
Plug-in Type 12/Top Ported
U
SS5Y5-M12- Stations D
B (Station 1)--------- (Station n)
(SY5000)
(SY3000)
(91.3)
(87.4)
1 P 1 P
(69.7)
2 B2 B2 B2 B2 B
( Pitch of
SY5000 ) Manual override
32.8 21.1 P = 16
Light/surge
voltage suppressor
(
Push-turn locking slotted type:
Press, then rotate it. ) 78.9
(
Pitch of
SY3000 ) 4(A) port side : Blue (For rubber seal)
: Grey (For metal seal)
(Slide locking manual override)
P = 12.5 (65.4)
2(B) port side : Yellow
LOCK
PE
B A B A B A B A B A
5.5
3/5
35
4A 4A
4A 4A 4A
113.4
26.5
FREE
X
1
(SY3000)
81.2
2B 2B
(SY3000)
(SY5000)
61.7
11
56.4
01 : 16.2
C: 14.5
(SY5000)
P
47.3
39.5
2B 2B 2B
2.7
4.7
One-touch fitting
[1(P), 3/5(E) port] One-touch fitting One-touch fitting
Applicable tube O.D.: Ø 10, Ø 3/8" [4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: Ø 4, Ø 5/32" Applicable tube O.D.: Ø 2
: Ø 6, Ø 1/4" : Ø 3.2, Ø 1/8"
: Ø 8, Ø 5/16" : Ø 4, Ø 5/32"
5.3 L4 : Ø 6, Ø 1/4"
(DIN rail mounting hole pitch: 12.5)
L3
Calculation formula for dimensions with Calculation formula for dimensions with D-sub
D-sub connector <IP40> and Flat ribbon connector <IP67>, Terminal block box (Spring type),
cable Terminal block box, Lead wire, Circular connector,
L1 = 12.5 x n1 + 16 x n2 + 76.4 EX500/600/250/260/126/120 serial transmission
L2 = 12.5 x n1 + 16 x n2 + 48 L1 = 12.5 x n1 + 16 x n2 + a + b x n3
M = (L1 + 6.1)/12.5 + 1 Decimal fractions are truncated. L2 = 12.5 x n1 + 16 x n2 x 48
L3 = 12.5 x M + 23 M = L1/12.5 + 1 Decimal fractions are truncated.
L4 = L3 – 10.5 L3 = 12.5 x M + 23
L5 = (L3 – L1 + 6.1)/2 L4 = L3 – 10.5
L5 = (L3 – L1)/2
n1: Number of valve stations of the SY3000
L6 = b x n3 + c
n2: Number of valve stations of the SY5000
n1: Number of valve stations of the SY3000
Coefficient n2: Number of valve stations of the SY5000
a b c
n3: Number of I/O units or input block stations
D-sub connector <IP67> 90.5 — —
∗ Refer to pages 120 and 121 for dimensions of the EX600
Terminal block box (Spring type) 128 — — serial transmission with I/O unit and page 132 for the
Terminal block box or Serial transmission: EX126 149.3 — — EX250 serial transmission with input block when L6, b,
and c are used for the calculation formula.
Lead wire or Circular connector 97 — —
EX500 Gateway Decentralised System 2 (128 points) 88.7 — —
EX500 Gateway Decentralised System (64 points) 88.5 — —
Serial transmission: EX600 (M12 connector) 141.5 47 81.5
Serial transmission: EX600 (7/8 inch connector) 158 47 81.5
Serial transmission: EX250 141.5 21 81.5
Serial transmission: EX260 88.7 — —
Serial transmission: EX120 84.7 — —
199
Plug-in Connector Connecting Base SY3000/5000/7000 Series
Plug-in Type 12/Top Ported
U
SS5Y7-M12- Stations D
B
(Station 1) (Station n)
(SY7000)
(SY5000)
(100.3)
(SY7000)
(98.2)
(SY5000)
88.8
83.8
1 P 1 P
(75.1)
2 B2 B2 B2 B2 B
3/5 E 3/5 E
4 A4 A4 A4 A4 A
D side U side
L1
33.9
(Pitch)
26.1 P = 19
(Pitch)
P = 19 42.2 (
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side: Blue (For rubber seal)
One-touch fitting
: Grey (For metal seal) 85.8
[1(P), 3/5(E) port] 2(B) port side: Yellow (Slide locking manual override)
Applicable tube O.D.: Ø 12, Ø 1/2"
PE
LOCK
3/5E B A B A B A B A B A
4A 4A 4A 4A 4A
21
128.8
FREE
SY5000: 95.7
SY7000: 96.7
(SY5000)
C: 14.5
01: 16.2
1P
(SY5000)
77.1
(SY7000)
(SY7000)
X 2B 2B 2B
22.6
61.8
59.9
57.7
2B 2B
2.4
1/8
3.9
4 x M5 mounting hole
1/4 [A(A), 2(B) port]
[A(A), 2(B) port]
20.7 L2 1.5
(DIN rail mounting hole pitch: 12.5) One-touch fitting (For SY5000)
[4(A), 2(B) port]
One-touch fitting (For SY7000) Applicable tube O.D.: Ø 4, Ø 5/32"
[4(A), 2(B) port] : Ø 6, Ø 1/4"
Applicable tube O.D.: Ø 6 , Ø 1/4" : Ø 8, Ø 5/16"
: Ø 8 , Ø 5/16"
: Ø 10, Ø 3/8"
: Ø 12
∗ Refer to page 179 for dimensions of the external pilot and elbow fittings.
∗ Refer to the pages below for L1, L2, L3, L4 dimensions and other
dimensions that are not specified in each wiring specification.
Dimensions of Type 12/Top ported: p. 184
D-sub connector <IP40> : p. 48
D-sub connector <IP67> : p. 51
Flat ribbon cable : p. 53
Terminal block box (Spring type) : p. 65
Terminal block box : p. 74
Lead wire : p. 84
Circular connector : p. 94
EX500 (128 points) : p. 104
EX500 (64 points) : p. 110
EX600 : pp. 122, 123
EX250 : p. 139
EX260 : p. 150
EX126 : p. 158
EX120 : p. 166
200
SY3000/5000/7000 Series Type 10, 11, 12
Connector Connecting Base Manifold Exploded View
U side
Manifold Exploded View p. 197
D side
LOC
K
FRE
E
Wiring
D-sub Connector <IP40> D-sub Connector <IP67> Terminal Block Box Terminal Block Box Lead Wire
/Flat Ribbon Cable p. 203 (Spring
(Spr Type) p. 205 p. 206
p. 202 p. 204
EX250 EX2
2660
EX260 E
EX126 20
EX120 EX
X180
EX180
p. 215 p. 216 p. 217 p. 218 p. 219
201
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series
Wiring
D-sub Connector <IP40>/Flat Ribbon Cable Manifold exploded view
q
U side
Locking bracket
(For D-sub connector)
LOC
Cover assembly K
Holding screw
D side
w Clamp bracket assembly
It is mounted only for the DIN rail mounting type. Refer to pages 221 to 224
The holding screw of the clamp bracket is for details on common parts.
tightened at one point.
(Tightening torque of holding screw: 1.4 N·m)
— — — Side ported
S — Side L10 Ø 10 — —
Metric size
R — — L12 Ø 12 — —
V — — LN9 Ø 5/16" — —
Side ported
RV — — Top LN11 Ø 3/8" — —
Inch size
VP — ∗1 LN13 Ø 1/2" — —
B — — B8 Ø8 — —
Side ported
BS — Bottom B10 Ø 10 — —
Metric size
BR — — B12 Ø 12 — —
BN9 Ø 5/16" — —
∗1 For silencer (supply side) Side ported
BN11 Ø 3/8" — —
E port is plugged. Inch size
∗ “B” for the bottom-ported type can be BN13 Ø 1/2" — —
selected for the SY5000/7000 series. 00∗1 Plug P/E port entry on one
00U∗2 Plug side or Top ported
SUP/EXH block assembly (D side) ∗1 It can be selected only if no symbol or “S” or “V” or “B” is
accessories and the number of accessories selected for the pilot and the piping.
Accessories SY3000 SY5000 ∗2 “00U” is available only for the D-sub connector type and it
SY7000 has an inch size locking bracket.
a Tension bolt None∗1 3 pcs.
∗1 Since the nuts are embedded in the SUP/EXH block
202
SY3000/5000/7000 Series
Wiring
D-sub Connector <IP67> Manifold exploded view
q
U side
Locking a
bracket Tension
bolt
Mounting screw
(Tightening torque: 0.8 N·m)
D side
Holding screw
Refer to pages 221 to 224
e Clamp bracket assembly for details on common parts.
It is mounted only for the DIN rail mounting type.
The holding screws of the clamp bracket is
tightened at two points.
(Tightening torque of holding screw: 1.4 N·m)
— — — Side ported
S — Side L10 Ø 10 — —
Metric size
R — — L12 Ø 12 — —
V — — LN9 Ø 5/16" — —
Side ported
RV — — Top LN11 Ø 3/8" — —
Inch size
VP — ∗1 LN13 Ø 1/2" — —
B — — B8 Ø8 — —
Side ported
BS — Bottom B10 Ø 10 — —
Metric size
BR — — B12 Ø 12 — —
∗1 For silencer (supply side) BN9 Ø 5/16" — —
Side ported
E port is plugged. BN11 Ø 3/8" — —
Inch size
∗ “B” for the bottom-ported type can be BN13 Ø 1/2" — —
selected for the SY5000/7000 series. 00∗1 Plug P/E port entry on one
00U∗2 Plug side or Top ported
SUP/EXH block assembly (D side) ∗1 It can be selected only if no symbol or “S” or “V” or “B” is
accessories and the number of accessories selected for the pilot and the piping.
Accessories SY3000 SY5000 ∗2 “00U” has an inch size locking bracket.
SY7000
a Tension bolt None∗1 3 pcs.
∗1 Since the nuts are embedded in the SUP/EXH block
203
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series
Wiring
Terminal Block Box (Spring Type) Manifold exploded view
q
U side
a
Tension
bolt
D side
Mounting screw for
connecting parts Holding Refer to pages 221 to 224
(Tightening torque: screw
for details on common parts.
0.8 N·m)
204
SY3000/5000/7000 Series
Wiring
Terminal Block Box Manifold exploded view
Mounting screw q
(Tightening torque: 0.8 N·m)
U side
w
a
Tension
bolt
Mounting screw
DIN rail holding screw (Tightening torque: 1.4 N·m)
(Tightening torque: 1.4 N·m)
205
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series
Wiring
Lead Wire Manifold exploded view
q
U side
w
a
Tension
bolt
Mounting screw
(Tightening torque: 0.8 N·m)
D side
q
U side
a
Tension
bolt
Mounting screw
(Tightening torque: 0.8 N·m)
D side
207
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series
Wiring
EX500 Gateway Decentralised System 2 (128 Points) Manifold exploded view
q
U side
w
a
Tension
bolt
D side
w EX500 SI unit
EX500 S103
e Clamp bracket assembly
Series Part no.
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A
∗ Part number is for one assembly.
208
SY3000/5000/7000 Series
Wiring
EX500 Gateway Decentralised System (64 Points) Manifold exploded view
q
U side
a
Tension
bolt
Mounting screw
(Tightening torque: 0.8 N·m)
D side
w EX500 SI unit
EX500 Q 0 01
Output specifications
0 NPN (Positive common)
1 PNP (Negative common)
209
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series
Wiring
EX600 Manifold exploded view
Mounting screw q
(Tightening torque: 0.8 N·m) U side
w
e
a
Tension
t bolt
D side
Holding screw
Side ported
VP — ∗1 L10 Ø 10 — —
Metric size
B — — L12 Ø 12 — —
BS — Bottom LN9 Ø 5/16" — —
Side ported
BR — — LN11 Ø 3/8" — —
Inch size
∗1 For silencer (supply side) LN13 Ø 1/2" — —
E port is plugged. B8 Ø8 — —
Side ported
∗ “B” for the bottom-ported type can be B10 Ø 10 — —
Metric size
selected for the SY5000/7000 series. B12 Ø 12 — —
SUP/EXH block assembly (D side) BN9 Ø 5/16" — —
Side ported
accessories and the number of accessories BN11 Ø 3/8" — —
Inch size
BN13 Ø 1/2" — —
Accessories SY3000 SY5000
SY7000 P/E port entry on one
00∗1 Plug
a Tension bolt None∗1 3 pcs. side or Top ported
∗1 Since the nuts are embedded in the SUP/EXH block ∗1 It can be selected only if no symbol or “S” or “V” or “B” is
selected for the pilot and the piping.
210
SY3000/5000/7000 Series
Manifold Parts Nos.
w Valve plate
EX600 ZMV2
∗ With mounting screws
(2 pcs. of M4 x 6 and 2 pcs. of M3 x 8)
e EX600 SI unit
EX600 S PR 1
Protocol Version
Symbol Description Symbol Description
PR PROFIBUS DP When MJ, EN, EC, or
—
DN DeviceNet™ PN is selected
MJ CC-Link A When PR or DN is selected
EN EtherNet/IP™
EC EtherCAT Output type
PN PROFINET Symbol Description Condition
1 PNP (Negative common) Can be selected by all protocols
2 NPN (Positive common) Can be selected by all protocols
3 PNP (Negative common) Can be selected in the case of EN/PN∗1
4 NPN (Positive common) Can be selected in the case of EN/PN∗1
∗1 For EN: Dual port EtherNet/IP™ product
For PN: IO-Link master compatible product
Protocol
Symbol SI unit type Description
EN Wireless base module EtherNet/IP™∗1
PN Wireless base module PROFINET∗1
SV Wireless remote module —∗1
∗1 The wireless system is suitable for use only in a country where it is
in accordance with the Radio Act and regulations of that country.
211
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series
Manifold Parts Nos.
t EX600 digital input unit
EX600 DX P B
Input type Number of inputs, open circuit detection, and connector
Symbol Description Symbol Number of inputs Open circuit detection Connector
P PNP B 8 No M12 connector (5 pins) 4 pcs.
N NPN C 8 No M8 connector (3 pins) 8 pcs.
C1 8 Yes M8 connector (3 pins) 8 pcs.
D 16 No M12 connector (5 pins) 8 pcs.
E 16 No D-sub connector (25 pins)
F 16 No Spring type terminal block (32 pins)
Joint assembly
r
Manifold exploded view
a
Tension
bolt
— — — L10 Ø 10 — —
Side ported
S — Side L12 Ø 12 — —
Metric size
R — — LN9 Ø 5/16" — —
V — — LN11 Ø 3/8" — —
Side ported
RV — — Top LN13 Ø 1/2" — —
Inch size
VP — ∗1 B8 Ø8 — —
B — — B10 Ø 10 — —
Side ported
BS — Bottom B12 Ø 12 — —
Metric size
BR — — BN9 Ø 5/16" — —
∗ 1 : For silencer (supply side). E port is Side ported
BN11 Ø 3/8" — —
Inch size
plugged. BN13 Ø 1/2" — —
∗: “B” for bottom ported can be selected P/E port entry on one
00∗1 Plug
side or Top ported
for the SY5000/7000 series.
SUP/EXH block assembly (D side)
∗1: It can be selected only if no symbol or “S” or “V” or “B” is selected for
accessories and the number of accessories the pilot and the piping.
Accessories SY3000 SY5000/7000
aTension bolt None∗1 3 pcs.
∗1: Since the nuts are embedded in the SUP/EXH block.
213
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series
EX245 S PN 1A
SI unit Connector type
PROFINET Symbol Communication connector Power supply connector
1A Push Pull connector (SCRJ): 2 pcs. Push Pull connector (24 V): 2 pcs.
2A Push Pull connector (RJ45): 2 pcs. Push Pull connector (24 V): 2 pcs.
7/8 inch connector (5-pin, Plug): 1 pc.
3A M12 connector (4-pin, Socket, D-coded): 2 pcs.
7/8 inch connector (5-pin, Socket): 1 pc.
EX245 DX1
Digital input module
specification
DX1 Digital input (16 inputs)
EX245 DY1
Digital output module
specification
DY1 Digital output (8 outputs)
EX245 EA2 3
214
SY3000/5000/7000 Series
Wiring
EX250 Manifold exploded view
q
U side
w
r a
Tension
t bolt
y
Holding screw D side
Side ported
VP — ∗1 L10 Ø 10 — —
Metric size
B — — L12 Ø 12 — —
BS — Bottom LN9 Ø 5/16" — —
Side ported
BR — — LN11 Ø 3/8" — —
Inch size
∗1 For silencer (supply side). LN13 Ø 1/2" — —
E port is plugged. B8 Ø8 — —
Side ported
∗ “B” for the bottom-ported type can be B10 Ø 10 — —
Metric size
SUP/EXH block assembly (D side) selected for the SY5000/7000 series. B12 Ø 12 — —
accessories and the number of accessories BN9 Ø 5/16" — —
Side ported
BN11 Ø 3/8" — —
Accessories SY3000 SY5000
SY7000 BN13 Ø 1/2" — —
Inch size
a Tension bolt None∗1 3 pcs. P/E port entry on one
00∗1 Plug
∗1 Since the nuts are embedded in the SUP/EXH block side or Top ported
∗1 It can be selected only if no symbol or “S” or “V” or “B” is
w EX250 SI unit selected for the pilot and the piping.
r Input block
EX250 S DN1
Communication protocol
EX250 IE 1
DN1 DeviceNet™ (Negative common) Block type
PR1 PROFIBUS DP (Negative common) 1 M12 connector, 2 inputs
AS3 AS-Interface (8 in/8 out, 31 slave modes, 2 isolated common type) (Negative common) 2 M12 connector, 4 inputs
AS5 AS-Interface (4 in/4 out, 31 slave modes, 2 isolated common type) (Negative common) 3 M8 connector, 4 inputs
AS7 AS-Interface (8 in/8 out, 31 slave modes, 1 common type) (Negative common)
AS9 AS-Interface (4 in/4 out, 31 slave modes, 1 common type) (Negative common) t EX250 end plate assembly
CA1A CANopen (Negative common)
EN1 EtherNet/IP™ (Negative common) EX250 EA1
∗ With mounting screws (2 pcs. of M3 x 10)
e Clamp bracket assembly
Series Part no. y Clamp bracket assembly for EX250 SI unit
SY3000 SY30M-15-1A
SY5000/7000 SY50M-15-1A SY30M 15 3A
∗ Part number is for one assembly. ∗ Part number is for one assembly.
215
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series
Wiring
EX260 Manifold exploded view
q
U side
w
a
Tension
bolt
q
U side
w
a
Tension
bolt
e
q
U side
a
Tension
bolt
D side
w
q U side
a
Tension
bolt
e
D side
RV — — Top L10 Ø 10 — —
Side ported
VP — ∗1 L12 Ø 12 — —
Metric size
B — — LN9 Ø 5/16" — —
BS — Bottom LN11 Ø 3/8" — —
Side ported
BR — — LN13 Ø 1/2" — —
Inch size
∗1: For silencer (supply side). E port is B8 Ø8 — —
Side ported
plugged. B10 Ø 10 — —
Metric size
∗: “B” for bottom ported can be selected B12 Ø 12 — —
for the SY5000/7000 series. BN9 Ø 5/16" — —
SUP/EXH block assembly (D side)
Side ported
BN11 Ø 3/8" — —
Inch size
accessories and the number of accessories BN13 Ø 1/2" — —
P/E port entry on one
Accessories SY3000 SY5000
SY7000 00∗1 Plug
side or Top ported
Tension bolt None∗1 3 pcs. ∗1: It can be selected only if no symbol or “S” or “V” or “B” is
∗1 Since the nuts are embedded in the SUP/EXH block. selected for the pilot and the piping.
u DIN rail
It is mounted only for
the DIN rail mounting
type (with DIN rail.)
A Manifold block
assembly
D side
EXH blocking disk assembly
t Refer to “Manifold Options”
Tie-rod on page 234. Holding screw i Clamp bracket assembly
(SY5000/7000: 3 pcs.) It is mounted only for the DIN
rail mounting type. (Tightening
torque of holding screw: 1.4 N·m)
∗ The figures show the SY3000 series.
q Base gasket
3 Connect the A manifold block assembly and B
SUP/EXH end block assembly to be added, and
tighten the tension bolt a.
w Connector
gasket
r Tie-rod for
Tightening torque for tension bolt a (M3): 0.8 N·m additional
e Manifold stations
block gasket
Caution
1. Be sure to shut off the power and air supplies before
disassembly.
Furthermore, since air may remain inside the actuator, Gaskets are mounted.
piping and manifold, confirm that the air is completely
exhausted before performing any work. ∗1 Manifold block assembly
2. When disassembly and assembly are performed, air No. Description Quantity Note
leakage may result if the tightening of the tension bolt is
For base, connector,
inadequate. qwe Gasket 3
and manifold block
SY3000: 2 pcs.
Tie-rod for
r additional stations
SY5000: 3 pcs.
SY7000: 3 pcs.
Refer to page 222 for ordering single unit.
221
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series
SY3000/5000/7000
SY30M-49-2-A SV2000-55-2A-A SY70M-49-2-A∗2 2 pcs. supplied (SY3000),
(10.5 mm pitch) (16 mm pitch) (19 mm pitch) 3 pcs. supplied (SY5000/7000)
Tie-rod for
additional
stations∗1
SY70M-49-1--A
SS5Y7-M∗∗ —
(19 mm pitch)
222
SY3000/5000/7000 Series
Upward elbow
C4 Ø4 — Bottom L8 Ø8 —∗1
Piping direction Metric
C6 Ø6 ported L10 Ø 10 — — size
1 Side/Top ported C8 Ø8 —∗1 Metric L12 Ø 12 — —
2 Bottom ported C10 Ø 10 — — size LN3 Ø 5/32" — — Side
∗ “2” (bottom ported) can be C12 Ø 12 — — LN7 Ø 1/4" — ported
selected for the N1 Ø 1/8" — — LN9 Ø 5/16" — ∗1 — Inch
Side/
SY5000/7000 series. N3 Ø 5/32" — Bottom LN11 Ø 3/8" — — size
N7 Ø 1/4" ported B4 Ø4 —
N9 Ø 5/16" —∗1 Inch B6 Ø6 Side
Downward elbow
size ported
N11 Ø 3/8" — — B8 Ø8 —∗1
Metric
Single wiring ∗1 Refer to mixed mounting type for Ø 8, Ø 5/16". B10 Ø 10 — — size
Marked with ß B12 Ø 12 — —
BN3 Ø 5/32" — — Side
BN7 Ø 1/4" — ported
Wiring type
BN9 Ø 5/16" —∗1 — Inch
S Single wiring
BN11 Ø 3/8" — — size
D Double wiring
00 Plug Top ported
Side/Bottom
C8 Ø8
ported
L8 Ø 8 Side ported B8 Ø8 Side ported
Wiring type C10 Ø 10 Metric size L10 Ø 10 Metric size B10 Ø 10 Metric size
S Single wiring C12 Ø 12 L12 Ø 12 B12 Ø 12
D Double wiring N7 Ø 1/4" Side/Bottom LN11 Ø 3/8" Side ported BN11 Ø 3/8" Side ported
N9 Ø 5/16" ported Inch size Inch size
N11 Ø 3/8" Inch size 00 Plug Top ported
223
Type 10, 11, 12
Connector Connecting Base Manifold Exploded View SY3000/5000/7000 Series
Side ported
L10 Ø 10 — —
Metric size
L12 Ø 12 — —
LN9 Ø 5/16" — —
Side ported
LN11 Ø 3/8" — —
Inch size
LN13 Ø 1/2" — —
B8 Ø8 — —
Side ported
B10 Ø 10 — —
Metric size
B12 Ø 12 — —
BN9 Ø 5/16" — —
Side ported
BN11 Ø 3/8" — —
Inch size
BN13 Ø 1/2" — —
P/E port entry on one side
00∗1 Plug
or Top ported
∗1 It can be selected only if no symbol or “S” or “V” or “B” is selected for
the pilot and the piping.
224
SY3000/5000/7000 Series
Cover assembly
(Internal pilot) SY 3 0M 4 1A
Dent for positioning
225
SY3000/5000/7000 Series
One-touch Fitting, Plug Assembly Part Nos.
Refer to “How to Replace One-touch Fittings” on page 320 for the replacement method.
One-touch fittings
Port size SY3000 SY5000 SY7000
Ø2 VVQ1000-50A-C2 — —
Ø 3.2 VVQ1000-50A-C3 — —
Ø4 VVQ1000-50A-C4 VVQ1000-51A-C4 —
Ø6 Straight type VVQ1000-50A-C6 VVQ1000-51A-C6 VVQ2000-51A-C6
Ø8 — VVQ1000-51A-C8 VVQ2000-51A-C8
Ø 10 — — VVQ2000-51A-C10
Ø 12 — — KQ2H12-17-X224
Metric size
Ø4 SZ3000-73-1A-L4 SZ3000-74-1A-L4 —
Ø6 SZ3000-73-1A-L6 SZ3000-74-1A-L6 SZ3000-83-1A-L6
Ø8 Elbow type — SZ3000-74-1A-L8 SZ3000-83-1A-L8
Ø 10 — — SZ3000-83-1A-L10
Ø 12 — — KQ2L12-17N-X224
Ø4 SZ3000-73-2A-L4 SZ3000-74-2A-L4 —
Ø6 SZ3000-73-2A-L6 SZ3000-74-2A-L6 SZ3000-83-2A-L6
A, B port∗1
Ø 5/32" KJL03-95-X224 — —
Ø 1/4" KJL07-95-X224 KQ2L07-14-X224 —
Elbow type
Ø 5/16" — KQ2L09-14-X224 —
Ø 3/8" — — KQ2L11-14-X224
Ø 5/32" KJL03-95-X225 — —
Ø 1/4" KJL07-95-X225 KQ2L07-14-X225 —
Long elbow type
Ø 5/16" — KQ2L09-14-X225 —
Ø 3/8" — — KQ2L11-14-X225
Ø8 VVQ1000-51A-C8 — —
Ø 10 Straight type — VVQ2000-51A-C10 —
Ø 12 — — VVQ4000-50B-C12
Metric size
Ø8 SZ3000-74-1A-L8 — —
Ø 10 Elbow type — SZ3000-83-1A-L10 —
Ø 12 — KQ2L12-19N-X224
Ø8 SZ3000-74-2A-L8 — —
Ø 10 Long elbow type — SZ3000-83-2A-L10 —
P, E port
Ø 12 — — KQ2W12-19N-X224
Ø 5/16" VVQ1000-51A-N9 — —
Ø 3/8" Straight type — VVQ2000-51A-N11 —
Ø 1/2" — — VVQ4000-50B-N13
Inch size
Ø 5/16" KQ2L09-14-X224 — —
Ø 3/8" Elbow type — KQ2L11-14-X224 —
Ø 1/2" — — KQ2L13-19N-X224
Ø 5/16" KQ2L09-14-X225 — —
Ø 3/8" Long elbow type — KQ2L11-14-X225 —
Ø 1/2" — — KQ2W13-19N-X224
∗1 A and B ports (Ø 8 and Ø 5/16") of the SY3000 and 5000 mixed mounting type are the same as those of the SY5000.
∗ Purchasing order is available in units of 10 pieces. Additionally, when performing the piping in the same orientation using the elbow type, please order
“elbow type” or “long elbow type” appropriately.
∗ Select the same port size for both the A and B ports.
Plug assembly
SY3000 SY5000 SY7000
A, B port VVQ0000-58A VVQ1000-58A VVQ2000-58A
P, E port VVQ1000-58A VVQ2000-58A SY9000-62-1A
∗ Purchasing order is available in units of 10 pieces.
226
SY3000/5000/7000 Series
Manifold Options
DIN rail dimensions/weight for the SY3000/5000 Plug-in connector connecting base
VZ1000-11-1-
∗ After confirming the L3 dimension in the dimensions table of each series, refer to the DIN rail dimensions table below and
specify the number in the box .
L
8 (7.5)
5.5
(35)
(25)
Rail mounting hole pitch 12.5
No. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
L dimension 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 273 285.5 298 310.5 323
Weight [g] 17.6 19.9 22.1 24.4 26.6 28.9 31.1 33.4 35.6 37.9 40.1 42.4 44.6 46.9 49.1 51.4 53.6 55.9 58.1
No. 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
L dimension 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 523 535.5 548 560.5
Weight [g] 60.4 62.5 64.9 67.1 69.4 71.6 73.9 76.1 78.4 80.6 82.9 85.1 87.4 89.6 91.9 94.1 96.4 98.6 100.9
No. 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56
L dimension 573 585.5 598 610.5 623 635.5 648 660.5 673 685.5 698 710.5 723 735.5 748 760.5 773 785.5 798
Weight [g] 103.1 105.4 107.6 109.9 112.1 114.4 116.6 118.9 121.1 123.4 125.6 127.9 130.1 132.4 134.6 136.9 139.1 141.4 143.6
No. 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71
L dimension 810.5 823 835.5 848 860.5 873 885.5 898 910.5 923 935.5 948 960.5 973 985.5
Weight [g] 145.9 148.1 150.4 152.6 154.9 157.1 159.4 161.6 163.9 166.1 168.4 170.6 172.9 175.1 177.4
DIN rail dimensions/weight for the SY7000 Plug-in connector connecting base
VZ1000-11-4-
∗ After confirming the L3 dimension in the dimensions table of each series, refer to the DIN rail dimensions table below and
specify the number in the box .
L
8
5.5
(35)
(25)
No. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
L dimension 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 273 285.5 298 310.5 323
Weight [g] 24.8 28 31.1 34.3 37.4 40.6 43.8 46.9 50.1 53.3 56.4 59.6 62.7 65.9 69.1 72.2 75.4 78.6 81.7
No. 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
L dimension 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 523 535.5 548 560.5
Weight [g] 84.9 88 91.2 94.4 97.5 100.7 103.9 107 110.2 113.3 116.5 119.7 122.8 126 129.2 132.3 135.5 138.6 141.8
No. 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56
L dimension 573 585.5 598 610.5 623 635.5 648 660.5 673 685.5 698 710.5 723 735.5 748 760.5 773 785.5 798
Weight [g] 145 148.1 151.3 154.5 157.6 160.8 163.9 167.1 170.3 173.4 176.6 179.8 182.9 186.1 189.2 192.4 195.6 198.7 201.9
No. 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71
L dimension 810.5 823 835.5 848 860.5 873 885.5 898 910.5 923 935.5 948 960.5 973 985.5
Weight [g] 205.1 208.2 211.4 214.5 217.7 220.9 224 227.2 230.4 233.5 236.7 239.8 243 246.2 249.3
227
Manifold Options SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options ∗ Refer to pages 239 to 241 for dimensions. M3: 0.8 N·m (SY5000/7000)
Individual SUP spacer assembly How to Order Individual SUP/EXH Spacer Assembly
[With a connector gasket, a base gasket, and two mounting screws One-touch fitting
(3 pcs. for the SY7000)] Straight type SY 3 0M 38 1 A C6
When the same manifold is used for different pressures, an individual
SUP spacer assembly is used as a supply port for different pressures. One-touch fitting
∗ When selecting a One-touch fitting elbow type for a spacer assembly, Elbow type SY 3 0M 38 2 A L6
use it faced upward, since it interferes with A and B port piping of
Type 10 manifolds.
Series
∗ When the elbows are facing upward in A and B ports in Type 10 3 SY3000
manifolds, they will interfere with the piping for the spacer assem- 5 SY5000
bly. Therefore, combine the A and B ports with straight types or 7 SY7000
elbows facing downward.
Spacer type
4(A) 38 Individual SUP spacer
2-position single valve 2(B)
Individual SUP spacer
39 Individual EXH spacer
assembly
Mounting
1(P') Individual SUP/EXH spacer assembly
screw 5(EA) 2 Short elbow type
1(P) 3 Long elbow type
3(EB)
Circuit diagram ∗ Select the long elbow type for a 3-position valve when
Base gasket
(Mounting example of a using Type 11 and Type 12 downward. However,
2-position single valve) Type 11 of the SY3000 series for the mixed mounting
of connector connecting bases cannot be used
Part numbers of mounting downward.
screw (For repairs)
SY3000: SY3000-23-12A (2 pcs.)
SY5000: SY5000-221-2A (2 pcs.) Port size (Metric/One-touch fittings)
Connector gasket SY7000: SY7000-221-2A (3 pcs.) Symbol P, E port SY3000 SY5000 SY7000
L4 Ø4 —
L6 Ø6
L8 Ø8 —
Individual EXH spacer assembly L10 Ø 10 — —
[With a connector gasket, a base gasket, and two mounting screws L12 Ø 12 — —
(3 pcs. for the SY7000)]
Port size (Inch/One-touch fittings)
When valve exhaust affects other stations due to the circuit
configuration, this spacer assembly is used for individual valve exhaust. Symbol P, E port SY3000 SY5000 SY7000
LN3 Ø 5/32" — —
∗ When selecting a One-touch fitting elbow type for a spacer assembly,
use it faced upward, since it interferes with A and B port piping of LN7 Ø 1/4" —
Type 10 manifolds. LN9 Ø 5/16" — —
∗ When the elbows are facing upward in A and B ports in Type 10 LN11 Ø 3/8" — —
manifolds, they will interfere with the piping for the spacer assem-
bly. Therefore, combine the A and B ports with straight types or el- Port size (Metric/One-touch fittings)
bows facing downward.
Symbol P, E port SY3000 SY5000 SY7000
4(A) C2 Ø2 — —
2-position single valve 2(B) C3 Ø 3.2 — —
Individual EXH spacer C4 Ø4 —
assembly C6 Ø6
3/5(E') C8 Ø8 —
Mounting
screw 5(EA) C10 Ø 10 — —
1(P) C12 Ø 12 — —
3(EB)
Circuit diagram Port size (Inch/One-touch fittings)
Base gasket (Mounting example of a
2-position single valve) Symbol P, E port SY3000 SY5000 SY7000
N1 Ø 1/8" — —
Part numbers of mounting N3 Ø 5/32" —
screw (For repairs) N7 Ø 1/4"
SY3000: SY3000-23-12A (2 pcs.) N9 Ø 5/16" —
SY5000: SY5000-221-2A (2 pcs.) N11 Ø 3/8" — —
Connector gasket SY7000: SY7000-221-2A (3 pcs.) ∗ When using in combination with the SY 57 30 01 -1-E (With
residual pressure release valve), the length of the required
mounting screws will differ. Please contact SMC for details.
228
SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options ∗ Refer to pages 239 to 241 for dimensions. M3: 0.8 N·m (SY5000/7000)
SUP stop valve spacer assembly with residual pressure release valve
[With a connector gasket, a base gasket, and two mounting screws
(3 pcs. for the SY7000)]
It is used to shut off the supply air to valves individually.
∗ Cannot be selected when the elbows are facing upward in A and B ports in Type
10 manifolds, since they will interfere with the piping for the spacer assembly
[How to mount SUP stop valve spacer assembly with residual pressure release valve] Valve mounting screw (Refer to page 222.)
Insert the SUP stop valve mounting screw from the side of the spacer assembly, Tightening torque:
and mount it to the manifold. SY3000 series: 0.16 N·m
Tighten the SUP stop valve mounting screw to the specified tightening torque. SY5000/7000 series: 0.8 N·m
Mount the valve and tighten the valve mounting screws to the specified For hexagon socket head cap screws
Nominal wrench size:
tightening torque after mounting the SUP stop valve spacer assembly with
SY3000 series: 1.5
residual pressure release valve. SY5000/7000 series: 2.5
Valve
∗ Install the plate type nut to the spacer assembly as shown in the figure if it SUP stop valve spacer assembly with
comes off. The SUP stop valve mounting screws can be tightened with a residual pressure release valve
hexagon wrench without removing the plate type nut.
∗ When the elbows are facing upward in A and B ports in Type 1 0 manifolds, Plate type nut
Hexagon wrench
SY3000 series:
they will interfere with the piping for the spacer assembly. Therefore, combine Nominal wrench size:
SY30M-57-1A (10 pcs. included)
the A and B ports with straight types or elbows facing downward. SY5000/7000 series: SY3000 series: 1.3
∗ This product is only for internal pilot specifications, as the external pilot air SY50M-57-1A (10 pcs. included) SY5000/7000 series: 2
cannot be shut off.
∗ If the product is equipped with a 3 -position closed centre, residual pressure SUP stop valve mounting screw
cannot be released, so use in combination with a 3 -port valve, which can be Tightening torque:
connected to the A, B piping port. SY3000 series: 0.16 N·m
SY5000/7000 series: 0.8 N·m
229
Manifold Options SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options ∗ Refer to pages 239 to 241 for dimensions. M3: 0.8 N·m (SY5000/7000)
Double check spacer assembly with residual pressure release valve (Side/Bottom ported) <Example>
[With a connector gasket, a base gasket, and two mounting screws (3 pcs. for the SY7000)] Double check spacer assembly with residual pressure release valve
It is used to hold the intermediate position of the cylinder for a long period of time. Use a 3-position 3-position exhaust centre valve
exhaust centre valve when the double check spacer assembly with residual exhaust valve is used.
It can also be used for drop prevention at the cylinder stroke end when supply residual
pressure is released by using a 2-position single/double valve.
∗ When the elbows are facing upward in A and B ports in Type 10 manifolds, they will interfere with the piping for
the spacer assembly. Therefore, combine the A and B ports with straight types or elbows facing downward.
Mounting screw
Specifications
Max. operating pressure 1.0 MPa
Min. operating pressure 0.1 MPa
Ambient and fluid temperatures –10 to 50 °C
SY3000 0.3 dm3/(s·bar)
Flow rate
characteristics: C
SY5000 0.7 dm3/(s·bar)
SY7000 1.1 dm3/(s·bar)
Max. operating frequency 3 Hz
230
SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options ∗ Refer to pages 239 to 241 for dimensions. M3: 0.8 N·m (SY5000/7000)
Interface regulator
[With a connector gasket, a base gasket, and two mounting screws (3 pcs. for the SY7000)]
Used when the supply pressure for each valve on the same manifold must be individually set (reduced pressure).
How to Order
SY 3 0M 05 P
Series Applicable valve∗3
3 SY3000 — For single, double, and 4-position
3 For 3-position
Pressure gauge option∗1 ∗1 In the case of the SY3000 series with a pressure gauge, when mounting on the manifold, use
M1 Without pressure gauge caution that the part numbers are different between the odd no. stations and the even no. stations
05 Pressure gauge with MPa display (For odd number station) to prevent the pressure gauges from interfering with each other.
06 Pressure gauge with MPa display (For even number station) If using a connector connecting base M10/11/12 (mixed mounting type) or laminating two or more
types of spacer type manifold options for the neighbouring stations, you can use only the model
N5 Pressure gauge with psi display (For odd number station)∗2
without a pressure gauge (M1).
N6 Pressure gauge with psi display (For even number station)∗2 ∗2 As per the new Measurement Law, gauges with a psi display will only be sold to overseas
customers.
∗3 In the case of the SY3000 series, use caution that the part numbers will differ depending on the
SY 5 0M 00 P one for single/double and 4- and 3-position due to the different length of solenoid valves. Also, if
you have selected a model with a pressure gauge, and if at least the one for 3-position is included
in the same manifold, use all the ones for 3-position to prevent the pressure gauges from
Series interfering with each other.
5 SY5000
7 SY7000 Regulating port
P 1(P) port Part numbers of mounting
Pressure gauge option A1 4(A) port (P controlled type, A port regulation) screw (For repairs)
M1 Without pressure gauge B1 2(B) port (P controlled type, B port regulation) SY3000: SY3000-23-12A (2 pcs.)
00 Pressure gauge with MPa display SY5000: SY5000-221-6A (2 pcs.)
N0 Pressure gauge with psi display∗2 SY7000: SY7000-221-6A (3 pcs.)
Mounting screw
Base gasket
Connector gasket
Specifications
Interface regulator model SY30M--- SY50M-- SY70M-- ∗1 3-position closed centre and pressure centre, and 4-position
Applicable valve model∗1 SY3 03 (R) SY5 03 (R) SY7 03 (R) dual 3-port valves are only available for 1(P) port pressure
regulation.
Regulating port 1(P), 4(A), 2(B)
∗2 Gasket and mounting screws are included in the weight.
Set pressure range 0.1 to 0.7 MPa ∗3 ( ): Denotes the values of SY30M---3
Maximum operating pressure 1.0 MPa ∗ Always apply pressure from 1(P) port in the base for interface
Fluid Air regulator.
Ambient and fluid temperatures –10 to 50 °C (No freezing) ∗ When using in combination with the SY 57 30 01 -1-E (With
With pressure gauge 33 (35)∗3 75 93 residual pressure release valve), the length of the required
Weight [g]∗2 mounting screws will differ. Please contact SMC for details.
Without pressure gauge 27 (29)∗3 69 87
(EA)5 3(EB)
(EA)5 3(EB) (EA)5 3(EB)
231
Manifold Options SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options: Spacer Combinations and Screw List q M3: 0.8 N·m (SY5000/7000)
q
q SY3000 (M2) w
w SY5000 (M3) e
e SY7000 (M3)
Combination
Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw
<Round head combination screw> SY3000- SY3000- SY5000- SY5000- SY7000- SY7000-
q: SY3000-23-24A A Valve 23-24A 222-1A 221-1A 222-1A 221-1A 222-1A
[for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves
w: SY5000-221-1A
(20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)] (30 pcs.)] (30 pcs.)]
e: SY7000-221-1A
<Hexagon socket head cap screw> SUP stop valve
A q: SY3000-222-1A spacer assembly
w: SY5000-222-1A B with residual
B e: SY7000-221-1A pressure
release valve SY30M-56-2A SY50M-56-2A SY70M-56-2A
q: SY30M-56-2A
(2 pcs.) (2 pcs.) (3 pcs.)
C w: SY50M-56-2A Individual
e: SY70M-56-2A SUP (EXH)
C
spacer
assembly
A Valve
<Round head combination screw>
q: SY3000-23-33A
w: SY5000-221-5A Double check
A e: SY7000-221-5A spacer assembly SY3000- SY5000- SY7000-
B with residual 23-33A — 221-5A — 221-5A —
B pressure release (2 pcs.) (2 pcs.) (3 pcs.)
valve
C Individual
SUP (EXH)
C
spacer
assembly
A Valve
<Round head combination screw>
q: SY3000-23-32A
w: SY5000-221-3A
A Individual
e: SY7000-221-3A SY3000- SY5000- SY7000-
SUP (EXH)
B 23-32A — 221-3A — 221-3A —
B spacer
(2 pcs.) (2 pcs.) (3 pcs.)
assembly
C Individual
EXH (SUP)
C
spacer
assembly
232
SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options: Spacer Combinations and Screw List w M3: 0.8 N·m (SY5000/7000)
q
q SY3000 (M2) w
w SY5000 (M3) e
e SY7000 (M3)
Combination
Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw
<Round head combination screw> SY3000- SY3000- SY5000- SY5000- SY7000- SY7000-
q: SY3000-23-24A A Valve 23-24A 222-1A 221-1A 222-1A 221-1A 222-1A
w: SY5000-221-1A [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves
e: SY7000-221-1A (20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)] (30 pcs.)] (30 pcs.)]
<Hexagon socket head cap screw> SUP stop valve
q: SY3000-222-1A spacer assembly
A
w: SY5000-222-1A B with residual
e: SY7000-222-1A pressure
B
release valve SY30M-56-3A SY50M-56-3A SY70M-56-3A
q: SY30M-56-3A Double check (2 pcs.) (2 pcs.) (3 pcs.)
C w: SY50M-56-3A spacer
e: SY70M-56-3A C assembly with
residual pressure
release valve
Individual
EXH (SUP)
D
spacer
assembly
A Valve
<Round head combination screw>
q: SY3000-23-32A
A w: SY5000-221-7A
e: SY7000-221-7A SY3000- SY5000- SY7000-
Interface
B 23-32A — 221-7A — 221-7A —
B regulator
(2 pcs.) (2 pcs.) (3 pcs.)
C
Individual
SUP (EXH)
C
spacer
assembly
233
Manifold Options SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options ∗ Refer to pages 239 to 241 for dimensions. M3: 0.8 N·m (SY5000/7000)
Individual SUP block assembly Mounting screw How to Order Individual SUP/EXH Block Assembly
On the circuit of the plug-in connector One-touch fitting
connection base, an individual SUP Straight type SY 3 0M 78 1 A C6
block assembly can be used to supply
air to a series of valves if a separate One-touch fitting
air supply is required, or if addition air Elbow type SY 3 0M 78 2 A L6
is required for additional air flow. Series
Individual SUP block assembly 3 SY3000
occupies 1 station. 5 SY5000
Blocking disks also supplied (2 Block type
7 SY7000
78 Individual SUP block
pieces). Can be used to block both SUP blocking disk
sides of the number of stations being assembly 79 Individual EXH block
isolated for individual air supply (as
shown in example). <Example> Individual SUP/EXH block assembly
∗ Specify the mounting position of the D side U side
2 Short elbow type (Type 12)
block as well as the position where 3 Long elbow type (Type 11)
5(EA) 5(EA)
the SUP passage is to be blocked 1(P) X X 1(P) ∗ Long elbow type is for the
3(EB) 3(EB) SY5000/7000 only.
on the manifold specification sheet.
Blocking is required for 1 or 2
positions for 1 set. (2 SUP blocking Port size (Metric/One-touch fittings)
disks to block SUP is attached to Symbol P, E port SY3000 SY5000 SY7000
individual SUP block.) L4 Ø4 —
∗ Electrical wiring is connected to a L6 Ø6
1(P)
number of stations in the individual (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) L8 Ø8 —
SUP block manifold. L10 Ø 10 — —
∗ When used in M10/11/12 (mixed L12 Ø 12 — —
mounting type), select the SY50M Port size (Inch/One-touch fittings)
type for SS5Y5 and the SY70M Symbol P, E port SY3000 SY5000 SY7000
type for SS5Y7. LN3 Ø 5/32" — —
∗ A structure to prevent screws falling LN7 Ø 1/4" —
out is in place on the individual SUP LN9 Ø 5/16" — —
block, making it much harder for the LN11 Ø 3/8" — —
mounting screws to fall out.
Port size (Metric/One-touch fittings)
Individual EXH block assembly Mounting screw Symbol P, E port SY3000 SY5000 SY7000
On the circuit of the plug-in connector C2 Ø2 — —
connection base, individual EXH C3 Ø 3.2 — —
block assembly can be used to C4 Ø4 —
individually exhaust series of valves C6 Ø6
when the exhaust from the valves C8 Ø8 —
would affect a number of other C10 Ø 10 — —
stations. C12 Ø 12 — —
Individual EXH block assembly
Port size (Inch/One-touch fittings)
occupies 1 station.
Symbol P, E port SY3000 SY5000 SY7000
Blocking disks also supplied (4 EXH blocking disk
N1 Ø 1/8" — —
pieces). Can be used to block both assembly
N3 Ø 5/32" —
sides of the number of stations being
<Example> N7 Ø 1/4"
isolated for individual exhaust. (as
D side U side N9 Ø 5/16" —
shown in example).
5(EA) X X 5(EA) N11 Ø 3/8" — —
∗ Specify the mounting position of the 1(P) 1(P)
X X
block as well as the position where 3(EB) 3(EB)
the EXH passage is to be blocked
on the manifold specification sheet.
Blocking is required for 1 or 2
positions for 1 set. (2 sets of EXH
blocking disks (4 pcs.) to block EXH
3(R)
is attached to individual EXH block.) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B)
∗ Electrical wiring is connected to a
number of stations in the individual
EXH block manifold.
∗ When used in M10/11/12 (mixed
mounting type), select the SY50M
type for SS5Y5 and the SY70M
type for SS5Y7.
∗ A structure to prevent screws falling
out is in place on the individual EXH
block, making it much harder for the
mounting screws to fall out.
234
SY3000/5000/7000 Series
Manifold Options
Blanking Plate with Output
[With two mounting screws]
The blanking plate extracts the individual signal of the manifold valve.
SY 3 0M 150 1A
Series Cable length
3 SY3000 — 300 mm
10 1000 mm
Connector type
— 1 2
Without connector With M12 connector With connector
(For ZK2 vacuum unit)
Made to Order
SUP/EXH blocking disk assembly (for connector type manifold, Type 10, 11, 12)
[SUP blocking disk]
By inserting the SUP blocking disk in the pressure supply passage of the SUP blocking EXH blocking
manifold valve, can provide two different high and low pressure in one Series
disk assembly disk assembly
manifold. SY3000 SY30M-40-1A SY30M-40-2A
[EXH blocking disk] SY5000 SY50M-40-1A SY50M-40-1A
By inserting the EXH blocking disk in the exhaust passage of the manifold valve, SY7000 SY70M-40-1A SY70M-40-1A
can separate the exhaust from the valve so it does not affect the other valves. It
can also be used for the manifold for the positive pressure and vacuum mixed
manifold. (2 pcs. are required to block FA/EB both sides of the EXH.)
Label for blocking disk ∗ If the blocking disk assembly is ordered using
Label to indicate and confirm on the manifold where the SUP/EXH the manifold specification sheet and ordered
blocking disk assemblies were inserted. (3 sheets each) at the same time as the manifold, the position
where the blocking disk assembly is inserted
will be labelled and shipped out.
235
Manifold Options SY3000/5000/7000 Series
Manifold Options
Back pressure check valve assembly (Retrofit or pre-installed type)
It prevents cylinder malfunction caused by other valve exhaust entry. Insert For SY3000
it into EA/EB port (valve mounting side) on the manifold side of a valve
which is affected. It is effective when a single-acting cylinder is used. EA port
∗ When ordering assemblies incorporated with a manifold, refer to the Ordering Example below
(when installed in all stations.) EB port
Back pressure check valve assembly
∗ When a check valve for back pressure prevention is desired and is to be
installed only in certain manifold stations, clearly indicate the part number 2 pcs. in 1 set
and specify the mounting position on the manifold specification sheet.
<Precautions>
1. The manifold installed type back pressure check valve assembly is For SY5000/7000
assembly parts with a check valve structure. However, since slight air
leakage against the back pressure is allowed due to its structure, adverse EA port
effects of the back pressure due to increase in exhaust resistance cannot
be prevented if the manifold exhaust port and other exhaust ports are put
together for piping or if the piping diameter is narrowed. As a result, this EB port
may cause the actuator and air operated equipment to malfunction. So, be
careful not to restrict the exhaust air. If the exhaust resistance becomes
large, select a built-in valve type with rubber seal. Mount the back pressure check valve
2. When the back pressure check valve assembly is mounted, please contact assemblies on the EA and EB ports in
SMC for valve flow rate characteristics. the order shown in the figure above.
Ordering Example Series Part no.
SS5Y3-10F1-05B-C6·····1 set (Type 10 5-station manifold base part no.) SY3000 SY30M-24-1A
∗SY3201-5U1·················· 5 sets (2-position double part no.)
∗SY30M-24-1A················5 sets (Back pressure check valve assembly part no.)
SY5000 SY50M-24-1A
The asterisk denotes the symbol for the assembly. SY7000 SY70M-24-1A
Dual flow fitting (for connector connecting base, Type 10, side ported)
This is a fitting for cylinder ports which enables simultaneous actuation and increase in flow rate of
valves for 2 stations. Clip
∗ When ordering assemblies incorporated into a manifold, refer to the Ordering Example below and
specify on the manifold specification sheet.
Ordering Example Dual flow fitting
SUP stop valve spacer assembly with residual pressure release valve
11.1
32.1
҂
26.3
Silencer A
C
(One-touch fitting connection type)
This silencer can be mounted to the 3/5 Series Model Effective area A B C
ØB
Ød
(E: EXH) port of the manifold in one step. For SY3000 (Ø 8) AN15-C08 20 mm2 45 13 20
For SY5000 (Ø 10) AN20-C10 30 mm2 57.5 16.5 30.5
Body Sound absorbing material For SY7000 (Ø 12) AN30-C12 41 mm2 71.5 20 43.5
∗ Shipped together with the product (Resin) (Resin sintered body)
Plug Dimensions
These are inserted in unused cylinder Applicable fitting size Applicable fitting size
Ø d (Metric size)
Model A L ØD Ø d (Inch size)
Model A L ØD
ports and P, E ports.
Ød
Manifold Options A transparent plastic plate to put a label with the name of the function of the solenoid valve
…
—
A24 — — — For 24 stations —
BA — — — —
B — — — —
B0 — — — —
B3 — — — For 3 stations —
…
…
—
B24 — — — For 24 stations —
Ordering Example ∗ Name plates cannot be mounted onto Type 1 2 (Top ported) and Type
SS5Y3-10F1-05UR-C6AA ······································· 1 set 10 (Side ported) mixed mounting types with top ported valves, nor onto
∗SY3200R-5U1·························································· 5 sets manifolds with optional laminated spacers.
∗ No name plate settings are available for the SY 3 0 0 0 /SY 5 0 0 0 mixed
The asterisk denotes the symbol for the assembly. mounting types. However, they are available for the SY 5 0 0 0 /SY 7 0 0 0
mixed mounting types.
<SY3000> <SY5000/7000>
n = 1 to 3 n = 4 to 24 n = 1 to 3 n = 4 to 24
42.3
62.5
3 1 2 3 4 5 n: Number
of stations
1 3 1 2 3 4 5 n: Number
Pitch of stations
Pitch
10.5
P = 16 (SY5000)
P = 19 (SY7000)
Make sure to mount
Make sure to mount
in the right direction. (20°)
in the right direction.
SY5000: SY50M-86-(N)
Tightening torque for mounting screw (M3): 0.8 N·m Tightening torque for mounting screw (M3): 0.8 N·m SY7000: SY70M-86-(N)
SY30M-86-(N) Name plate
Mounting screw Name plate Mounting screw is the number of stations (1 to 24).
Name plate bracket Name plate bracket
(M3) is the number of stations (1 to 24). (M3)
SY30M-85-1A
Name plate bracket assembly
(Supplied individually) SY50M-85-1A
Align this line along (For SY5000 only) Align this line along
Name plate insertion hole the end of the Name plate bracket assembly the end of the
Port block 2-position valve. (Supplied individually) 2-position valve.
SUP/EXH
SUP/EXH block
Figure 1 Figure 2
block
Figure 1 Figure 2
Insertion hole
237
Manifold Options SY3000/5000/7000 Series
Manifold Options
∗ A transparent plastic plate to put a label with the name of the function of the solenoid valve
Name plate bracket assembly part number and number of items ordered
Model SS5Y3-10 SS5Y5-10/11
Name plate assembly part number SY30M-85-1A SY50M-85-1A
Internal pilot
2 pcs.
Manifold SUP/EXH U/D piping
block assembly Internal pilot
2 pcs.
double sided piping Caution
Pilot type 2 pcs.
External pilot
and 1 pc.∗1 1. Be sure to shut off the power and air supplies before
U/D piping
P, E port entry mounting the name plate bracket assembly.
External pilot
Not required∗1 Furthermore, since air may remain inside the
double sided piping
actuator, piping, and manifold, confirm that the air is
∗1 If the manifold is an external pilot, an insertion slot for name plates is on the port block completely exhausted before performing any work.
of the SUP/EXH block assembly. Thus, a bracket assembly is no longer required on the 2. When disassembly and assembly are performed, air
port piping side. leakage may result if the tightening of the bracket
∗ Name plate bracket assembly is not required for the SY7000. mounting screws is inadequate.
238
SY3000/5000/7000 Series
C6: 92.3
N7: 96.1
LN7: 72.3
63.1
84.1
LN7: 63.8
L6: 69.8
L6: 61.3
92.6
92.6
92.6
101.2
92.6
101.2
111.6
112.8
3.6
14
3.6
<Type 10, 12>
One-touch fitting
(SUP port, EXH port) One-touch fitting
<Type 10>
Applicable tubing O.D.: Ø 4, Ø 5/32" (SUP port, EXH port)
: Ø 6, Ø 1/4" Applicable tubing O.D.: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
Individual SUP/EXH spacer SUP stop valve spacer assembly with Interface regulator Individual SUP/EXH block
assembly (Side ported) residual pressure release valve assembly (Side ported)
: Ø 3.2, Ø 1/8
: Ø 4, Ø 5/32"
62.6
: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
40.4
: Ø 6, Ø 1/4"
78.1
48
78.1
(59.2)
39.5
(100.7)
92.2
92.6
103.2
(111.7)
109.8
(118.3)
92.6
101.2
92.6
92.6
Max. 14
(2)
239
Manifold Options SY3000/5000/7000 Series
One-touch fitting
(SUP port, EXH port)
Applicable tubing O.D.: Ø 4, Ø 5/32"
(108.8)
101.2
: Ø 6, Ø 1/4"
(88.9)
(76.8)
: Ø 8, Ø 5/16"
73.2
63.7
113.4
113.4
116.7
113.4
126.5
113.4
142.5
138.7
126.7
113.4
5.5
18.2
5.7
<Type 10, 11, 12> <Type 10, 11>
One-touch fitting One-touch fitting
(SUP port, EXH port) (SUP port, EXH port)
Applicable tubing O.D.: Ø 4
Applicable tubing O.D.: Ø 4,
: Ø 6, Ø 1/4"
: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
: Ø 8, Ø 5/16"
Individual SUP/EXH spacer SUP stop valve spacer assembly with Interface regulator Individual SUP/EXH block
assembly (Side ported) residual pressure release valve assembly (Side ported)
: Ø 8, Ø 5/16" : Ø 8, Ø 5/16"
96.2
92.4
79.1
54.6
90.7
(38.5)
51.6
113.4
113.4
127.6
127.9
145.6
113.4
113.4
142.7
(3)
Max. 21
240
SY3000/5000/7000 Series
(121.1)
114.9
(95.2)
(83.2)
80.1
128.8
128.8
133.2
128.8
128.8
145.1
145.1
164.1
167.1
21.7
7.1
7.1
One-touch fitting One-touch fitting
<Type 10, 11, 12> (SUP port, EXH port) (SUP port, EXH port)
Applicable tubing O.D.: Ø 6, Ø 3/8" <Type 10, 11> Applicable tubing O.D.: Ø 6, Ø 3/8"
:Ø8 :Ø8
: Ø 10 : Ø 10
: Ø 12 <Type 12> : Ø 12
<Type 11, 12>
Individual SUP/EXH spacer SUP stop valve spacer assembly with Individual SUP/EXH block
assembly (Side ported) residual pressure release valve assembly (Side ported)
One-touch fitting
One-touch fitting
(SUP port, EXH port)
(SUP port, EXH port) Applicable tubing O.D.: Ø 6, Ø 3/8"
Applicable tubing O.D.: Ø 6, Ø 1/4" :Ø8
100.9
: Ø 8, Ø 5/16"
(86.8)
: Ø 10
: Ø 10, Ø 3/8"
: Ø 12
: Ø 12
100.9
68.8
56.8
128.8
148.7
(For Ø 12)
(126.3)
(For Ø 12)
(126.3)
(138.2)
(138.2)
(2)
241
Manifold Options SY3000/5000/7000 Series
103.1
(42.4)
96.1
82.8
58.3
One-touch fitting
(SUP port, EXH port)
Applicable tubing O.D.: Ø 8, Ø 3/8"
: Ø 10
: Ø 12
128.8
143.8
154.9
161.8
164.1
Max. 21
<Type 11>
<Type 10, 11, 12>
242
243
Plug-in Metal Base
Side ported
Bottom ported
Top ported
244
SY3000/5000/7000 Series Type 50, 51, 52
Plug-in Metal Base
Manifold Specifications
M5 x 0.8, 1/8
SY3000 Ø 2 One-touch fitting, Ø 3.2 One-touch fitting, Ø 4 One-touch fitting, Ø 6 One-touch fitting
Ø 1/8" One-touch fitting, Ø 5/32" One-touch fitting, Ø 1/4" One-touch fitting
Port size
1/8, 1/4
4(A), 2(B) port SY5000 Ø 4 One-touch fitting, Ø 6 One-touch fitting, Ø 8 One-touch fitting
Ø 5/32" One-touch fitting, Ø 1/4" One-touch fitting, Ø 5/16" One-touch fitting
1/4
SY7000 Ø 6 One-touch fitting, Ø 8 One-touch fitting, Ø 10 One-touch fitting, Ø 12 One-touch fitting
Ø 1/4" One-touch fitting, Ø 5/16" One-touch fitting, Ø 3/8" One-touch fitting
245
Type 50, 51, 52
Plug-in Metal Base SY3000/5000/7000 Series
246
Plug-in Metal Base
Type 50
Side Ported D-sub Connector Flat Ribbon Cable
SY3000/5000/7000 Series
Type 51
Bottom Ported
RoHS
How to Order Manifolds
SS5Y 3 50 F 1 05 D C6
q w e r t y u i o !0
q Series w Type e Connector type
3 SY3000 50 Side ported F: D-sub connector P: Flat ribbon cable
5 SY5000 51 Bottom ported (25 pins) (26 pins)
7 SY7000 50R Side ported, External pilot
∗ External pilot is not available
for the bottom-ported type.
t Wiring type
— All double wiring∗1
S All single wiring∗2
How to Order Manifold Assembly ∗1 All double wiring: 2-position single, double, 3-position, and 4-position
valves can be used on all manifold stations.
∗2 All single wiring: Available only for the manifold which has 2-position
Example (SS5Y3-50F2-) single for all stations
2-position double (24 VDC) Note that 2-position double, 3-, or 4-position valves cannot be used.
2-position single (24 VDC)
SY3100-5U1 (3 sets)
SY3200-5U1 (1 set) ∗ If a mix of single and double wiring is required, it is supplied as a
3-position closed special order.
centre (24 VDC)
SY3300-5U1 (1 set)
y Valve stations
F: D-sub connector (25 pins) P: Flat ribbon cable (26 pins)
Symbol Stations Note Symbol Stations Note
ide 02 2 stations All 02 2 stations All
Us
…
double double
s
n
wiring wiring
tio
12 12 stations 12 12 stations
ta
S
(5 stations)
…
single single
2
SS5Y3-50F2-05D-C6
1
double double
∗SY3300-5U1 ················· 1 set (3-position closed centre part no.) wiring wiring
09 9 stations 04 4 stations
The asterisk denotes the symbol for the assembly. 02 2 stations All 02 2 stations All
Prefix it to the part numbers of the valve, etc.
…
single single
• For the valve arrangement, the valve closest to the D side is considered the 1st station. 12 12 stations wiring 08 8 stations wiring
• Under the manifold part number, state the valves to be mounted in order starting
∗ This also includes the number of the blanking plate assembly.
with the 1st station as shown in the figure above. If the arrangement becomes too
complicated, specify the details on a manifold specification sheet.
∗ When mixing top-ported configurations, select from those listed on page 268.
In such cases, use caution as there is also output on the A and B ports on the base side.
Specify on the manifold specification sheet if plugs are required for the A and B ports on
the base side.
247
Plug-in Metal Base SY3000/5000/7000 Series
— Rc C3 Ø 3.2 — —
Fixed
F G C4 Ø4 —
N NPT C6 Ø6 —
T NPTF C8 Ø8 —
C10 Ø 10 — —
!0 Mounting KC2 Ø2 — — Type 50 Type 51
— Direct mounting KC3 Ø 3.2 — — (Side ported) (Bottom ported)
D DIN rail mounting (With DIN rail) KC4
Replaceable
Ø4 —
D0 DIN rail mounting (Without DIN rail)
KC6 Ø6
D3 For 3 stations Specify a length longer
KC8 Ø8 —
…
N7 Ø 1/4" —
N9 Ø 5/16" —
N11 Ø 3/8" — —
KN1 Ø 1/8" — — Type 50 Type 51
KN3 (Side ported) (Bottom ported)
Replaceable
Ø 5/32" —
KN7 Ø 1/4"
KN9 Ø 5/16" —
KN11 Ø 3/8" — —
M∗1 Mixed sizes
P, E port size (Thread piping) 1/8 1/4 3/8
∗1 When ports are of mixed sizes, indicate the piping specifications on the
manifold specification sheet.
Protective class
class # (Mark: )
248
SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 0 0 5 1
q w e r t y u i o !0 !1
Base mounted
Protective class
class # (Mark: )
249
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 50/Side Ported
U M5
C, N (D)
SS5Y3-50(R)F 12 - Stations D - KC, KN B
6.1 (Station 1)---(Station n)
50RF 12 - Stations UD
manual override)
(Slide locking
(68.7)
68.3
62.6
54.6
2B 2B 3
[Plug for external pilot]
7.1
32
22.6
4A 4A 2B
4A
11.8
C4, C6: 6.6
C2, C3: 42.4
∗ The above drawing shows when P,
(Pitch)
C4, C6: 41.8 P = 10.5 E port entry is D.
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 2
: Ø 3.2, Ø 1/8"
D side L3 U side : Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
5.3 L4
(Connector entry
(DIN rail mounting hole pitch: 12.5)
Manual override upward direction)
(Pitch)
DIN rail holding screw
(For DIN rail mounting)
45.1 P = 10.5 (
Push-turn locking slotted type:
Press, then rotate it. )
Applicable connector: D-sub
JIS-X-5101
MIL-C-24308
equivalent ( )
14 24.1 4(A) port side : Blue (For rubber seal)
Light/surge : Grey (For metal seal)
DIN rail bracket mounting screw M5 x 0.8 (External pilot)
(8) voltage 2(B) port side : Yellow
(For DIN rail mounting) suppressor [Pilot EXH port]
DIN rail
B A B A B A B A B A
92.7
89
5EA
PE
14 A 14 A 14 A 14 A 14 A
16.8 17.2
15.9 16.2
79
5.5
64.4
35
56.9
21.8 16
1P
32.5
29.8
26.6
X
12 B 12 B 12 B 12 B 12 B
3EB
4 x Ø 4.5 2 x M2.6
L2 8 8.6
)
(For mounting) 4
Replaceable: 7.7
2 x 4-40 UNC
(L5) 14.5 [For inch size thread]
L1
22.1
Fixed: 4.1
2B 2B
7.1
7.1
32
32
22.6
22.6
4A 4A
M5 x 0.8
6.6 (Pitch)
[4(A), 2(B) port] P = 10.5
(Pitch) 48.4
41.8 P = 10.5
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 2
: Ø 3.2, Ø 1/8"
: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17
250
SY3000/5000/7000 Series
Plug-in Type 50/Side Ported
U
SS5Y3-50(R)F 21 - Stations D -01(D)
B
(Station 1)------(Station n)
6.1
50RF 12 - Stations UD
manual override)
(Slide locking
(68.7)
68.3
62.6
54.6
2B 2B
[Plug for external pilot]
2B
7.1
32
22.6
4A 4A
4A
7.5
(Pitch)
11.8
41.8 P = 12.5 1/8 ∗ The above drawing shows when P,
[4(A), 2(B) port] E port entry is D.
D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5)
Manual override
DIN rail holding screw 45.1
(Pitch)
P = 12.5 (
Push-turn locking slotted type:
Press, then rotate it. ) Applicable connector: D-sub (JIS-X-5101
MIL-C-24308 )
equivalent
(For DIN rail mounting)
14 24.1 4(A) port side : Blue (For rubber seal)
Light/surge M5 x 0.8 (External pilot)
4 x Ø 4.5 (8) : Grey (For metal seal)
voltage [Pilot EXH port]
suppressor 2(B) port side : Yellow
(For mounting)
DIN rail
B A B A B A B A B A
(Connector entry
92.7
upward direction)
89
5EA
14 A 14 A 14 A 14 A 14 A
PE
16.8 17.2
15.9 16.2
79
5.5
64.4
35
56.9
21.8 16
1P
32,5
29.8
26.6
X
12 B 12 B 12 B 12 B 12 B
3EB
8.6 2 x M2.6
4 L2 8
2 x 4-40 UNC
14.5
(L5) L1 [For inch size thread]
22.1
DIN rail bracket mounting screw 28
(For DIN rail mounting)
1/8
[1(P), 5(EA), 3(EB) port]
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5
L4 100 112.5 125 137.5 150 162.5 175 187.5 200 212.5 225
L5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5
251
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 50/Side Ported
U 01
C, N (D)
SS5Y5-50(R)F 12 - Stations D - KC One-touch fitting
, KN B
[4(A), 2(B) port]
Applicable tube O.D.: Ø 4, Ø 5/32"
6.1 (Station 1)----------- (Station n) : Ø 6, Ø 1/4"
50RF 12 - Stations UD
: Ø 8, Ø 5/16"
manual override)
(Slide locking
3
[Plug for external pilot]
(74.7)
74.3
68.6
2B
60.6
2B 2B
7.8
38
27.3
4A 4A
4A
10
∗ The above drawing shows when P,
14.3
45.8 P = 16
D side U side
L3
5.3 L4 Manual override
(For DIN rail mounting) 50 P = 16 Light/surge 4(A) port side : Blue (For rubber seal)
16 24.1 voltage : Grey (For metal seal) M5 x 0.8 (External pilot)
4 x Ø 4.5 suppressor 2(B) port side : Yellow [Pilot EXH port]
(8)
(For mounting)
DIN rail
B A B A B A B A B A (Connector entry
14 A 14 A 14 A 14 A 14 A
PE
5EA
106.2
upward direction)
5.5
23.2
116.6
96.2
35
20
81.6
74.1
20
1P
24.6
20
49.4
43.8
40.2
3EB
30.2
X
12 B 12 B 12 B 12 B 12 B
L2 12.3
)
5 2 x M2.6
Replaceable: 8.5
28
34
DIN rail bracket mounting screw
(For DIN rail mounting) 1/4
(
2B 2B
9.8
7.8
38
38
27.3
27.3
4A 4A
8.4 (Pitch)
(Pitch)
51.6 P = 16
45.8 P = 16
One-touch fitting
1/8 [4(A), 2(B) port]
[4(A), 2(B) port] Applicable tube O.D.: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5
252
SY3000/5000/7000 Series
Plug-in Type 50/Side Ported
U
SS5Y5-50(R)F 21 - Stations D -02(D)
B
manual override)
(Slide locking
3
(74.7)
74.3
[Plug for external pilot]
68.6
60.6
2B 2B
2B
9.8
38
27.3
4A 4A
4A
10
14.3
45.8 P = 17.5 [4(A), 2(B) port] E port entry is D.
D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent
DIN rail holding screw
(For DIN rail mounting) 50
(Pitch)
P = 17.5
(
Push-turn locking slotted type:
Press, then rotate it. )
Light/surge 4(A) port side : Blue (For rubber seal) M5 x 0.8 (External pilot)
4 x Ø 4.5 16 24.1 voltage : Grey (For metal seal) [Pilot EXH port]
suppressor 2(B) port side : Yellow
(For mounting)
DIN rail
B A B A B A B A B A (Connector entry
upward direction)
PE
14 A 14 A 14 A 14 A 14 A
5EA
106.2
5.5
23.2
116.6
96.2
35
20
81.6
74.1
20
1P
24.6
20
49.4
43.8
40.2
3EB
30.2
X
12 B 12 B 12 B 12 B 12 B 8
12.3
5 L2
18 2 x M2.6
(L5) L1
2 x 4-40 UNC
28
DIN rail bracket mounting screw [For inch size thread]
(For DIN rail mounting) 34
1/4
[1(P), 5(EA), 3(EB) port]
M5 x 0.8 (External pilot)
[External pilot port]
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 123 135.5 148 173 185.5 210.5 223 235.5 260.5 273 298
L4 112.5 125 137.5 162.5 175 200 212.5 225 250 262.5 287.5
L5 17.5 15 12.5 16 13.5 17.5 15 12.5 16 13.5 17.5
253
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 50/Side Ported
U 02
C, N (D)
SS5Y7-50(R)F 12 - Stations D - KC, KN B
6.1
78.3
84
67.1
2B 2B
3
44.5
9.4
[Plug for external pilot]
32.4
4A 4A
2B
10
10.8
mounting)
(Pitch)
14.3
46.6 P = 19
One-touch fitting
[4(A), 2(B) port] ∗ The above drawing shows when P,
Applicable tube O.D.: Ø 8, Ø 5/16" E port entry is D.
: Ø 10, Ø 3/8"
(Station 1) (Station n)
D side U side ∗: These figures show the “SS5Y7-50F2-05B-C10”.
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override
B A B A B A B A B A
5.5
PE
14 A 14 A 14 A 14 A 14 A
5EA
116.7
23.8
28
102.1
35
133.2
92.1
84.6
24
1P
(59.9)
23.8
28.2
49.7
44.1
3EB
X
32.1
12 B 12 B 12 B 12 B 12 B
NC
NC
18.1
(5.4)
4 x Ø 4.5
(For mounting) 5 L2 20.9
(L5) L1 3/8 34.5
[1(P), 5(EA), 3(EB) port] 40.5
M5 x 0.8 (External pilot)
X: External pilot port
Port size 02 One-touch fitting (Replaceable) 2 x M2.6
2 x 4-40 UNC
[For N or T thread]
2B 2B
44.5
44.5
10.3
9.4
32.4
31.5
4A 4A
10.8 (Pitch)
(Pitch) 55.7 P = 19
46.6 P = 19 (11)
One-touch fitting
1/4 (22.9) [4(A), 2(B) port]
[4(A), 2(B) port] (For Ø 12) Applicable tube O.D.: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
: Ø 12
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 123 148 160.5 185.5 198 223 235.5 260.5 273 298 310.5
L4 112.5 137.5 150 175 187.5 212.5 225 250 262.5 287.5 300
L5 15.5 18.5 15.5 18.5 15 18 15 18 14.5 17.5 14.5
254
SY3000/5000/7000 Series
Plug-in Type 50/Side Ported
P U M5
SS5Y3-50(R) PG 21 - Stations D - KC
C, N
, KN
(D)
PH B 50PJG (20 pins) 50PH (10 pins)
Triangle mark
(Station 1)---(Station n) Triangle mark
For PC wiring
18
manual override)
(Slide locking
(81.4)
68.3
62.6
54.6
2B 2B
5EA
5EA
PCW type
PE
PE
7.1
32
22.6
4A 4A
1P
1P
X
X
3EB
3EB
(For DIN rail
mounting)
7.5
C2, C3: 5.4
11.8
C4, C6: 6.6 Applicable connector: Applicable connector:
20 pins MIL type with strain relief 10 pins MIL type with strain relief
C2, C3: 42.4 (Pitch) (Conforming to MIL-C-83503) (Conforming to MIL-C-83503)
C4, C6: 41.8 P = 10.5 One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 2
: Ø 3.2, Ø 1/8"
: Ø 4, Ø 5/32"
D side U side
L3 : Ø 6, Ø 1/4"
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override
Applicable connector:
DIN rail
B A B A B A B A B A
(Connector entry
92.7
PE
5EA
89
14 A 14 A 14 A 14 A 14 A
16.8 17.2
15.9 16.2
79
5.5
upward direction)
64.4
35
56.9
21.8 16
1P
32.2
29.8
26.6
12 B 12 B 12 B 12 B 12 B
3EB
4 L2 8
[External pilot port]
(L5) L1 14.5
1/8
(Fixed:4.1
22.1
DIN rail bracket mounting screw [1(P), 5(EA), 3(EB) port]
(For DIN rail mounting) 28
2B 2B
50R PJ 12 - Stations UD
7.1
7.1
32
32
22.6
22.6
4A 4A
3
6.6 M5 x 0.8 (Pitch) [Plug for external pilot]
[4(A), 2(B) port] 48.4 P = 10.5 2B
(Pitch)
41.8 P = 10.5 One-touch fitting 4A
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17
255
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 50/Side Ported
P U
SS5Y3-50(R) PG 21 - Stations D -01(D)
PH B
(Station 1) ----- (Station n)
50R PJ 12 - Stations UD
18
manual override)
(Slide locking
(81.4)
68.3
62.6
[Plug for external pilot]
54.6
2B 2B 2B
7.1
32
22.6
4A 4A 4A
mounting)
(Pitch)
7.5
∗ The above drawing shows when P,
11.8
41.8 P = 12.5
E port entry is D.
1/8
[4(A), 2(B) port]
D side U side
L3
5.3 L4 Manual override Applicable connector:
(DIN rail mounting hole pitch: 12.5)
(Pitch) (
Push-turn locking slotted type:
Press, then rotate it. ) 26 pins MIL type with strain relief
(Conforming to MIL-C-83503)
DIN rail holding screw 45.1 P = 12.5 4(A) port side : Blue (For rubber seal)
: Grey (For metal seal) Triangle mark
(For DIN rail mounting) 14 24.1 Light/surge
2(B) port side : Yellow M5 x 0.8 (External pilot)
voltage
DIN rail bracket mounting screw (8) suppressor [Pilot EXH port]
(For DIN rail mounting)
DIN rail
B A B A B A B A B A
92.7
89
5EA
PE
14 A 14 A 14 A 14 A 14 A
16.8 17.2
15.9 16.2
79
5.5
64.4
35
56.9
21.8 16
1P
32.2
29.8
26.6
X
12 B 12 B 12 B 12 B 12 B
3EB
4 x Ø 4.5 4 L2 8 8.6
1/8
(For mounting)
(L5) L1 [1(P), 5(EA), 3(EB) port] 14.5
22.1 (Connector entry
upward direction)
28
50PJG (20 pins) 50PH (10 pins) M5 x 0.8 (External pilot)
Triangle mark [External pilot port]
5EA
PCW type
PE
PE
1P
1P
X
X
3EB
3EB
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5
L4 100 112.5 125 137.5 150 162.5 175 187.5 200 212.5 225
L5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5
256
SY3000/5000/7000 Series
Plug-in Type 50/Side Ported
P U 01
SS5Y5-50(R) PG 21 - Stations D - KC
C, N
, KN
(D)
PH B 50PJG (20 pins) 50PH (10 pins)
(Station 1) ----------- (Station n)
18 Triangle mark
Triangle mark
For PC wiring
manual override)
(Slide locking
(87.4)
74.3
68.6
60.6
2B 2B
7.8
38
PCW type
PE
PE
27.3
5EA
5EA
4A 4A
1P
1P
10
3EB
3EB
(Pitch)
X
14.3
45.8 P = 16
One-touch fitting
[4(A), 2(B) port] Applicable connector: Applicable connector:
Applicable tube O.D.: Ø 4, Ø 5/32" 20 pins MIL type with strain relief 10 pins MIL type with strain relief
: Ø 6, Ø 1/4"
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)
: Ø 8, Ø 5/16"
D side L3 U side
Applicable connector:
5.3 L4 26 pins MIL type with strain relief
Manual override
(DIN rail mounting hole pitch: 12.5) (Conforming to MIL-C-83503)
DIN rail holding screw
(For DIN rail mounting) 50
(Pitch)
P = 16
(
Push-turn locking slotted type:
Press, then rotate it. ) Triangle mark
4(A) port side : Blue (For rubber seal) M5 x 0.8 (External pilot)
Light/surge
16 24.1 : Grey (For metal seal)
DIN rail bracket mounting screw voltage [Pilot EXH port]
(8) suppressor 2(B) port side : Yellow
(For DIN rail mounting)
DIN rail
B A B A B A B A B A
PE
14 A 14 A 14 A 14 A 14 A
(Connector entry
5EA
106.2
5.5
23.2
116.6
96.2
35
20
upward direction)
81.6
74.1
20
1P
24.6
20
49.4
43.8
40.2
3EB
30.2
8
X
12 B 12 B 12 B 12 B 12 B
12.3
)
5 L2
Replaceable: 8.5
4 x Ø 4.5 18
(L5) L1
(For mounting) 28
Fixed: 4.9
2B
2B 3
9.8
38
27.3
7.8
4A
4A
2B
One-touch fitting 4A
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5
257
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 50/Side Ported
P U
SS5Y5-50(R) PG 21 - Stations D -02(D)
PH B
50R PJ 12 - Stations UD
(Station 1) ------------- (Station n)
18
manual override)
3
(Slide locking
[Plug for external pilot]
(87.4)
74.3
2B
68.6
60.6
2B 2B
4A
9.8
38
27.3
4A 4A
10
∗ The above drawing shows when P,
mounting)
8.4 E port entry is D.
(Pitch)
14.3
[4(A), 2(B) port]
45.8 P = 17.5
D side U side
L3
5.3 L4 Manual override Applicable connector:
(DIN rail mounting hole pitch: 12.5) 26 pins MIL type with strain relief
DIN rail
holding screw
(Pitch)
P = 17.5
(
Push-turn locking slotted type:
Press, then rotate it. ) (Conforming to MIL-C-83503)
Triangle mark
50 4(A) port side : Blue (For rubber seal)
(For DIN Light/surge
16 24.1 : Grey (For metal seal) M5 x 0.8 (External pilot)
rail mounting) voltage suppressor 2(B) port side : Yellow
(8) [Pilot EXH port]
DIN rail
B A B A B A B A B A
PE
14 A 14 A 14 A 14 A 14 A
(Connector entry
5EA
106.2
5.5
23.2
116.6
96.2
35
20
upward direction)
81.6
74.1
20
1P
24.6
20
49.4
43.8
40.2
3EB
30.2
X
12 B 12 B 12 B 12 B 12 B 8
12.3
5 L2
18
(L5) 4 x Ø 4.5
L1 M5 x 0.8 (External pilot)
(For mounting) 28
DIN rail bracket mounting screw [External pilot port]
34
(For DIN rail mounting) 1/4
[1(P), 5(EA), 3(EB) port]
50PJG (20 pins) 50PH (10 pins)
Triangle mark
Triangle mark
For PC wiring
∗: These figures show the “SS5Y5-50P2-05B-02”.
∗: Only connectors are different for 50PG, 50PH and 50J.
L1 to L5 dimensions are the same as 50P type.
PCW type
PE
PE
5EA
5EA
1P
1P
3EB
3EB
X
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 123 135.5 148 173 185.5 210.5 223 235.5 260.5 273 298
L4 112.5 125 137.5 162.5 175 200 212.5 225 250 262.5 287.5
L5 17.5 15 12.5 16 13.5 17.5 15 12.5 16 13.5 17.5
258
SY3000/5000/7000 Series
Plug-in Type 50/Side Ported
P U 02
SS5Y7-50(R) PG 21 - Stations D - KC
C, N
, KN
(D)
PH B
50PJG (20 pins) 50PH (10 pins)
(Station 1) (Station n)
18 For PC wiring Triangle mark Triangle mark
manual override)
(Slide locking
(93.9)
78.3
84
67.1
2B 2B
PE
PE
PCW type
5EA
5EA
44.5
9.4
32.4
4A 4A
1P
1P
3EB
3EB
X
X
(For DIN rail
10.8
mounting)
10
(Pitch)
14.3
46.6 P = 19
One-touch fitting
[4(A), 2(B) port] Applicable connector: Applicable connector:
Applicable tube O.D.: Ø 8, Ø 5/16" 20 pins MIL type with strain relief 10 pins MIL type with strain relief
: Ø 10,Ø 3/8" (Conforming to MIL-C-83503) (Conforming to MIL-C-83503)
D side U side
L3
5.3 L4 Applicable connector:
(DIN rail mounting hole pitch: 12.5) Manual override 26 pins MIL type with strain relief
DIN rail (Conforming to MIL-C-83503)
holding screw 52
(Pitch)
P = 19
( Push-turn locking slotted type:
Press, then rotate it. ) Triangle mark
(For DIN rail mounting) 4(A) port side: Blue (For rubber seal)
16 24.1 (Light/surge voltage : Grey (For metal seal) M5 x 0.8 (External pilot)
DIN rail bracket suppressor)
(8) 2(B) port side: Yellow PE: Pilot EXH port
mounting screw
(For DIN rail mounting)
(DIN rail) B A B A B A B A B A
PE
14 A 14 A 14 A 14 A 14 A
5EA
116.7
5.5
23.8
35
28
102.1
133.2
92.1
84.6
24
1P
23.8
59.9
28.2
49.7
44.1
8 (Connector
3EB
X
32.1
12 B 12 B 12 B 12 B 12 B entry upward
direction)
NC
NC
4 x Ø 4.5
18.1
(5.4)
(For mounting) 5 L2
20.9
(L5) L1
3/8 34.5
[1(P), 5(EA), 3(EB) port] 40.5
∗: These figures show the “SS5Y7-50P2-05B-C10”. M5 x 0.8 (External pilot)
X: External pilot port
3
[Plug for external pilot]
2B 2B 2B
44.5
44.5
10.3
9.4
32.4
31.5
4A 4A 4A
55.7 (Pitch) P = 19
10.8 (Pitch) ∗ The above drawing shows when P,
46.6 P = 19 One-touch fitting E port entry is D.
(11)
[4(A), 2(B) port]
1/4 Applicable tube O.D.: Ø 6 ,Ø 1/4"
(22.9)
[4(A), 2(B) port] : Ø 8, Ø 5/16"
(For Ø 12) : Ø 10, Ø 3/8"
: Ø 12
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 123 148 160.5 185.5 198 223 235.5 260.5 273 298 310.5
L4 112.5 137.5 150 175 187.5 212.5 225 250 262.5 287.5 300
L5 15.5 18.5 15.5 18.5 15 18 15 18 14.5 17.5 14.5
259
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 51/Bottom Ported
M5, 01
SS5Y3-51F 12- Stations D- CKC, N,
KN
(Pitch)
46.4 P = 10.5 One-touch fitting
23.6 [4(A), 2(B) port] Panel fitting dimensions
4 x M4 x 0.7, thread depth 4 Applicable tube O.D.: Ø 2
21.1
: Ø 4, Ø 5/32" 2 x Ø 4.5
: Ø 6, Ø 1/4" (For 9 stations or more)
4
29.8
3EB 2B 2B
56.4
40
17.8
1P
52.4
C2, C3, C4 : 16
: 15
56.4
16
Refer to panel cut dimensions for details.
[1(P), 5(EA), 3(EB) port]
2 x M4 x 0.7 L3 4 x M4 x 0.7
(For 9 stations or more) L2 C6 4 x Ø 4.5 4 4
(Station 1) ---(Station n) L3
6.1
L2
manual override)
(Slide locking
(68.7)
68.3
62.6
54.6
32
Manual override
2 x M2.6
(Pitch)
(
Push-turn locking slotted type:
Press, then rotate it. ) 2 x 4-40 UNC
[For N or T thread]
4(A) port side : Blue (For rubber seal)
D side 45.1 P = 10.5 U side : Grey (For metal seal)
14 24.1 2(B) port side : Yellow
(8)
4 x Ø 4.5
(For mounting)
16
B A B A B A B A B A
92.7
89
14 A 14 A 14 A 14 A 14 A
64.4
32.2
12 B 12 B 12 B 12 B 12 B
21.8
(Max. 3) L1
Port size M5 Port size 01 One-touch fitting (Replaceable)
32
32
) 32
C6: 12.8
N7: 16.6
20.1
(
29.8
29.8
29.8
17
1P 1P 1P
Port Size 01
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 — — — — — — — 77.8 84 90.3 96.5
260
SY3000/5000/7000 Series
Plug-in Type 51/Bottom Ported
01, 02
SS5Y5-51F 12- Stations D- CKC, N,
KN
(Pitch)
50 P = 16
24 2 x M4 x 0.7 One-touch fitting
4 x M4 x 0.7, thread depth 5 (For 9 stations or more) [4(A), 2(B) port] Panel fitting dimensions
(For mounting)
Applicable tube O.D.: Ø 4, Ø 5/32"
40.2
25.2
: Ø 8, Ø 5/16"
20 20
71.6
5
1P
4 x Ø 4.5
5EA 4A 4A
61.6
71.6
Cut dimensions for panel mounting
20
1/4
C4, C6 : 14.8
: 17.2
Refer to panel cut dimensions for details. 4 x M4 x 0.7
[1(P), 5(EA), 3(EB) port]
L3 4 x Ø 4.5
5 5
L2
C8
L3
6.1 (Station 1) ------ (Station n) L2
manual override)
(Slide locking
(74.7)
74.3
68.6
60.6
38
Manual override
2 x M2.6
D side 50
(Pitch)
P = 16 U side (
Push-turn locking slotted type:
Press, then rotate it. ) 2 x 4-40 UNC
[For inch size thread]
4(A) port side : Blue (For rubber seal)
16 24.1 : Grey (For metal seal)
2(B) port side : Yellow
(8)
4 x Ø 4.5
(For mounting)
B A B A B A B A B A
106.2
14 A 14 A 14 A 14 A 14 A
116.6
81.6
30.2 20
49.4
12 B 12 B 12 B 12 B 12 B
(Max. 3) L1
∗: These figures show the “SS5Y5-
Port size 01 Port size 02 One-touch fitting (Replaceable)
51F2-05D-C8”.
(Pitch) (Pitch) (Pitch)
50 P = 16 50 P = 17.5 50 P = 16
9.7
40.2
40.2
40.2
1P 1P 1P
17.5
14.5
14.8
38
38
(15.5)
Port Size 02
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 — — — — — — — 100.5 109.3 118 126.8
261
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 51/Bottom Ported
02
SS5Y7-51F 12 - Stations D- CKC, N,
KN
(D)
Port size 02 One-touch fitting (Replaceable)
(Pitch) 3/8
(Max. 3) 52 P = 19 [1(P), 5(EA), 3(EB) port]
(For Ø 12)
M4 x 0.7 thread depth 5
(29.5)
(For 9 stations or more)
27
Fitting dimensions for
panel mounting
5
3EB 2B 2B
dimensions for details.
(17.6)
23 23
81.1
1P
5EA 4A 4A
One-touch fitting
[4(A), 2(B) port]
L3 Applicable tube O.D. C8 : Ø 8 One-touch fitting
C10: Ø 10
5 L2 [4(A), 2(B) port]
N9 : Ø 5/16"
L1 N11: Ø 3/8" Applicable tube O.D.: Ø 6, Ø 1/4"
1/4" : Ø 8, Ø 5/16"
4 x M4 x 0.7 thread depth 5 [4(A), 2(B) port] : Ø 10, Ø 3/8"
(For mounting) : Ø 12
32.8
22 33.1
3EB 2B 3EB 2B
1P
(Slide locking
22.6
(81.2)
5EA 4A 5EA 4A
78.3
84
67.1
44.5
(5.4)
D side U side
Manual override
(Light/surge voltage suppressor)
(
Push-turn locking slotted type:
Press, then rotate it. )
52
(Pitch)
P = 19 4(A) port side: Blue (For rubber seal)
: Grey (For metal seal)
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent
16 24.1
(8) 2(B) port side: Yellow
4 x Ø 4.5
B A B A B A B A B A
(For mounting) 14 A 14 A 14 A 14 A 14 A
116.7
133.2
92.1
84.6
32.1 24
59.9
2 x M2.6
2 x 4-40 UNC
[For N or T thread]
4 x Ø 4.5 2 x Ø 4.5
(For 9 stations or more)
5
24 27.1
81.1
72.1
4 x M4 x 0.7
5 5 4 x Ø 4.5
L3
L2
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 — — — — — — — 107.5 117 126.5 136
262
SY3000/5000/7000 Series
Plug-in Type 51/Bottom Ported
P M5, 01
SS5Y3-51 PG 21 - Stations D- CKC, N, Panel fitting dimensions
(For 9 stations
PH KN
17.8 or more)
2 x Ø 4.5
4
46.4 P = 10.5 (For 9 stations or more)
(Pitch) One-touch fitting 40
23.6
[4(A), 2(B) port] (For 9 stations or more)
4 x M4 x 0.7, thread depth 4
Applicable tube O.D.: Ø 2 4 x Ø 4.5
21.1
16.8
52.4
56.4
16
: Ø 4, Ø 5/32"
29.8
56.4
1P 4 x Ø 4.5
4 4
5EA 4A 4A
L3
16.8
68.3
62.6
54.6
PCW type
32
(4.1)
B A B A B A B A B A
92.7
89
14 A 14 A 14 A 14 A 14 A
32.2
12 B 12 B 12 B 12 B 12 B
(Connector entry
upward direction)
21.8
(Max. 3) L1
∗: These figures show the “SS5Y3-
Port size M5 Port size 01 One-touch fitting (Replaceable) 51P2-05D-C6”.
(Pitch) (Pitch) (Pitch)
20.1
21.1
20.1
29.8
29.8
17
1P 1P 1P
One-touch fitting
M5 x 0.8 1/8
[4(A), 2(B) port]
[4(A), 2(B) port] [4(A), 2(B) port]
Applicable tube O.D.: Ø 2
: Ø 3.2, Ø 1/8"
: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
32
32
32
16.6 )
(C6:N7: 12.8
Port Size 01
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 — — — — — — — 77.8 84 90.3 96.5
263
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 51/Bottom Ported
P 01, 02
SS5Y5-51 PG 21 - Stations D- CKC, N,
KN
PH Panel fitting dimensions
50 P = 16
2 x Ø 4.5
25.2
(Pitch)
2 x M4 x 0.7 (For 9 stations or more)
5
24 (For 9 stations or more) One-touch fitting 4 x Ø 4.5
x M4 x 0.7, thread depth 5 [4(A), 2(B) port]
61.6
71.6
(For mounting) Applicable tube O.D.: Ø 4, Ø 5/32"
20
: Ø 6, Ø 1/4" 4 x M4 x 0.7
40.2
3EB 2B 2B
: Ø 8, Ø 5/16"
4 x Ø 4.5
20 20
71.6
1P 5 5
L3
5EA 4A 4A
L2
Cut dimensions for panel mounting
1/4
C4, C6 : 14.8
: 17.2
PCW type
74.3
68.6
60.6
38
(4.9)
(Pitch)
(
Push-turn locking slotted type:
Press, then rotate it. )
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)
4(A) port side : Blue (For rubber seal)
50 P = 16
: Grey (For metal seal)
16 24.1 2(B) port side : Yellow Triangle mark Applicable connector:
(8) 26 pins MIL type with strain relief
4 x Ø 4.5
(Conforming to MIL-C-83503)
(For mounting)
D side B A B A B A B A B A
U side
106.2
14 A 14 A 14 A 14 A 14 A
116.6
81.6
30.2 20
49.4
12 B 12 B 12 B 12 B 12 B
(Connector entry
upward direction)
(Max. 3) L1
Port size 01 Port size 02 One-touch fitting (Replaceable)
∗: These figures show the “SS5Y5-
(Pitch) (Pitch) (Pitch) 51P2-05D-C8”.
50 P = 16 50 P = 17.5 50 P = 16
9.7
40.2
40.2
40.2
1P 1P 1P
17.5
14.5
14.8
5EA 4A 5EA 4A
5EA 4A
38
38
(15.5)
Port Size 02
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 — — — — — — — 100.5 109.3 118 126.8
264
SY3000/5000/7000 Series
Plug-in Type 51/Bottom Ported
P 02
SS5Y7-51 PG 21 - Stations D- CKC, N,
KN
(D)
PH
24 27.1
PCW type
81.1
72.1
4 x M4 x 0.7
5 5 4 x Ø 4.5
L3
L2
Applicable connector: Applicable connector:
20 pins MIL type with strain relief 10 pins MIL type with strain relief
(Conforming to MIL-C-83503) (Conforming to MIL-C-83503)
4 x M4 x 0.7 thread depth 5
(For mounting) 3/8
(Pitch)
(Max. 3) 52 P = 19 [1(P), 5(EA), 3(EB) port]
Port size 02 One-touch fitting (Replaceable)
M4 x 0.7 thread depth 5
27 (For 9 stations or more)
Fitting dimensions for
panel mounting
5
3EB 2B 2B
23 23
81.1
1P
5EA 4A 4A
32.8
22 33.1
3EB 2B 3EB 2B
manual override)
(Slide locking
(93.9)
1P 1P
78.3
84
67.1
22.6
44.5
5EA 4A 5EA 4A
(5.4)
D side U side
Manual override ∗: These figures show the “SS5Y7-51P2-05D-C10”.
(Light/surge voltage suppressor)
(Pitch)
(
Push-turn locking slotted type:
Press, then rotate it. )
52 P = 19 4(A) port side: Blue (For rubber seal)
: Grey (For metal seal) Applicable connector:
16 24.1
2(B) port side: Yellow Triangle mark 26 pins MIL type with strain relief
(8)
(Conforming to MIL-C-83503)
4 x Ø 4.5
B A B A B A B A B A
(For mounting) 14 A 14 A 14 A 14 A 14 A
116.7
133.2
92.1
84.6
32.1 24
59.9
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 — — — — — — — 107.5 117 126.5 136
265
266
Plug-in Metal Base
D-sub Connector Flat Ribbon Cable
Type 52
Top Ported
SY3000/5000/7000 Series ®
RoHS
How to Order Manifolds
SS5Y 3 52 F 1 05 D
q w e r t y u i o
q Series w Type e Connector type
3 SY3000 52 Top ported F: D-sub connector P: Flat ribbon cable
5 SY5000 52R Top ported, External pilot (25 pins) (26 pins)
7 SY7000
t Wiring type
— All double wiring∗1
All single wiring∗2
S
y Valve stations
∗1 All double wiring: 2-position single, double, 3-position, and 4-position
valves can be used on all manifold stations. F: D-sub connector (25 pins) P: Flat ribbon cable (26 pins)
∗2 All single wiring: Available only for the manifold which has 2-position Symbol Stations Note Symbol Stations Note
single for all stations 02 2 stations 02 2 stations
Note that 2-position double, 3-, or 4-position valves cannot be used. All All
…
single single
12 12 stations wiring 12 12 stations wiring
Example (SS5Y3-52F2-) PG: Flat ribbon cable (20 pins) PH: Flat ribbon cable (10 pins)
2-position double (24 VDC) Symbol Stations Note Symbol Stations Note
2-position single (24 VDC)
SY3130-5U1-C6 (3 sets) SY3230-5U1-C6 (1 set) 02 2 stations All 02 2 stations All
…
single single
12 12 stations wiring 08 8 stations wiring
∗ This also includes the number of the blanking plate assembly.
Us
ide u P, E port entry i Thread type
ions U U side∗1 — Rc
tat D side∗1
S D 00F G
Manifold base 3 B Both sides 00N NPT
2
(5 stations) 1 00T
ide
∗1 Plugs are mounted on the opposite NPTF
SS5Y3-52F2-05D Ds side of the selected ports.
267
Plug-in Metal Base SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported
1 Single ∗ Be careful of the energising time when the One-touch fitting (Metric)
2-position power saving circuit is selected. Refer to page Symbol A, B port SY3000 SY5000 SY7000
2 Double
3 Closed centre 316 for details. C2 Ø2 — —
4 3-position Exhaust centre C3 Ø 3.2 — —
5 Pressure centre i Rated voltage C4
C6
Ø4
Ø6
—
A∗1 4-position N.C./N.C. 5 24 VDC
B∗1 dual N.O./N.O. C8 Ø8 —
6 12 VDC
C∗1 3-port N.C./N.O. C10 Ø 10 — —
C12 Ø 12 — —
∗1 Only the rubber seal type is available
for the 4-position dual 3-port valve. o Light/surge voltage suppressor One-touch fitting (Inch)
and common specification Symbol A, B port SY3000 SY5000 SY7000
e Seal type Symbol With light
Surge voltage Common
suppressor specification
N1
N3
Ø 1/8"
Ø 5/32"
—
—
—
0 Rubber seal
— — — N7 Ø 1/4"
1 Metal seal
R — Non-polar N9 Ø 5/16" —
U N11 Ø 3/8" — —
r Pilot type S —
Positive
Z common
—
R
Internal pilot
External pilot NS — Negative !2 Thread type
NZ common — Rc
∗ For the non-polar type, be careful of surge F G
t Back pressure check valve voltage intrusion. N NPT
(Built-in valve type) Refer to page 317 for details. T NPTF
∗ Only “Z” and “NZ” types are available with a ∗ Only — is available for M5.
— None
power saving circuit.
H Built-in
∗ Only the rubber seal type is available.
∗ The back pressure check valve is not
!0 Manual override !3 Type of mounting screw
available for the 3-position type or the —: D: — Round head combination screw
SY7000. Non-locking Push-turn B Hexagon socket head cap screw
push type locking K Round head combination screw (Drop prevention type)
slotted H Hexagon socket head cap screw (Drop prevention type)
y Pilot valve option type ∗ For “K” and “H,” the valve body cover has a
— Standard (0.7 MPa) drop prevention construction to stop the
B Quick response type (0.7 MPa) mounting screws from falling out when the
K∗1 High pressure type (1.0 MPa) valve is removed for maintenance, etc.
E: F: ∗ When ordering a valve individually, the
∗1 Only the metal seal type is available base gasket is not included.
for the high pressure type. Push-turn Slide locking
locking lever type Since the base gasket is attached to the
type manifold, please order the base gasket
separately if it is needed for maintenance.
Refer to page 290 for base gasket and
mounting screw part numbers.
∗ “B” and “H” cannot be selected for the
individual SUP/EXH spacer assembly or
∗ Refer to page 36 for the safety slide locking interface regulator.
manual override.
Protective class
class # (Mark: )
268
SY3000/5000/7000 Series
Plug-in Type 52/Top Ported
Dimensions: SY3000 Series Metal Base D-sub Connector, Flat Ribbon Cable
F U
P 1 Stations D
SS5Y3-52(R) PG 2- -(D)
PH B
F
52R PJ 12 - Stations UD
(Station 1)---(Station n)
6.1
3
[Plug for external pilot]
)
C6: 76.8
N7: 80.6
(68.7)
62.6
54.6
(
32
∗ The above drawing shows when P,
E port entry is D.
mounting)
11.8
D side U side
L3
5.3 L4 Manual override
DIN rail
5.5
B A B A B A B A B A
(Connector entry
upward direction)
92.7
4A 4A 4A 4A 4A
5EA
89
PE
16.8 17.2
15.9 16.2
79
64.4
56.9
21.8 16
1P
2 x M2.6
32.2
11
32.1
35
29.8
X
26.6
2B 2B 2B 2B 2B
3EB
2 x 4-40 UNC
[For inch size thread]
4 x Ø 4.5 8.6
8 One-touch fitting
(For mounting) 4 L2 14.5
[4(A), 2(B) port] M5 x 0.8 (External pilot)
(L5) L1 Applicable tube O.D.: Ø 2 22.1 [External pilot port]
: Ø 3.2, Ø 1/8" 28
M5 x 0.8 1/8
: Ø 4, Ø 5/32"
[4(A), 2(B) port] : Ø 6, Ø 1/4" [1(P), 5(EA), 3(EB) port]
B A B A B A
4A 4A 4A
5EA
5EA
5EA
PE
PE
PE
PCW type
1P
1P
1P
X
2B 2B 2B
3EB
3EB
3EB
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17
269
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 52/Top Ported
Dimensions: SY5000 Series Metal Base D-sub Connector, Flat Ribbon Cable
F U
P 1 Stations D
SS5Y5-52(R) PG 2- -(D) F
52R PJ 12 - Stations UD
PH B
(Station 1)----------- (Station n)
6.1
3
[Plug for external pilot]
(86.7)
(74.7)
72.3
mounting)
14.3
38
∗ The above drawing shows when P,
E port entry is D.
10 Manual override
D side U side
(
Push-turn locking slotted type:
Press, then rotate it. )
L3 4(A) port side : Blue (For rubber seal)
DIN rail 5.3 L4 : Grey (For metal seal)
2(B) port side : Yellow
Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent
holding screw (DIN rail mounting hole pitch: 12.5)
(For DIN rail (Pitch) 74.3
mounting) 50 P = 16 Light/surge (Slide locking manual override)
16 24.1 voltage 68.6
DIN rail bracket suppressor M5 x 0.8 (External pilot)
mounting screw (8) [Pilot EXH port]
01 : 16.2
C : 14.5
(For DIN
rail mounting)
PE
5EA
upward direction)
106.2
5.5
23.2
116.6
96.2
20
35
81.6
74.1
20
1P
24.6
20
49.4
43.8
40.2
40.2
2 x M2.6
3EB
30.2
X
2B 2B 2B 2B 2B
2 x 4-40 UNC
[For inch size thread]
1/8 12.3
4 x Ø 4.5 One-touch fitting 18 M5 x 0.8 (External pilot)
[4(A), 2(B) port]
(For mounting) [4(A), 2(B) port] [External pilot port]
5 L2 28
Applicable tube O.D.: Ø 4, Ø 5/32" 1/4
(L5) L1 : Ø 6, Ø 1/4" 34
[1(P), 5(EA), 3(EB) port]
: Ø 8, Ø 5/16"
B A B A B A
4A 4A
PE
PE
4A
PE
5EA
5EA
5EA
PCW type
1P
1P
1P
3EB
3EB
3EB
X
2B 2B 2B
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5
270
SY3000/5000/7000 Series
Plug-in Type 52/Top Ported
Dimensions: SY7000 Series Metal Base D-sub Connector, Flat Ribbon Cable
F U
P 1 Stations D
SS5Y7-52(R) PG 2- -(D)
PH B
52PH (10 pins) 52P (26 pins)
Triangle mark 16 (9.9) Triangle mark 16 (9.9)
F
52R PJ 12 - Stations U
D
B A B A
PE
PE
4A 4A
5EA
5EA
3
[Plug for external pilot]
1P
1P
3EB
3EB
X
X
2B 2B
6.1
B A
(A, B port: Ø 12)
PE
4A
PCW type
5EA
(110.3)
(98.4)
1P
(81.2)
87
67.1
44.5
3EB
X
2B
(For DIN rail
Applicable connector:
mounting)
10
(Conforming to MIL-C-83503)
D side U side
L3
DIN rail 5.3 L4
holding screw (DIN rail mounting hole pitch: 12.5)
Manual override Applicable connector: D-sub ( JIS-X-5101
MIL-C-24308 )
equivalent
(For DIN
rail mounting) 52
P = 19
(Pitch)
(Push-turn locking slotted type:
Press, then rotate it. ) 84
16 24.1 4(A) port side: Blue (For rubber seal) (Slide locking manual override)
(Light/surge voltage
suppressor) : Grey (For metal seal) M5 x 0.8 (External pilot) 78.3
DIN rail bracket
(8) 2(B) port side: Yellow
mounting screw PE: Pilot EXH port
(For DIN
rail mounting)
(DIN rail) B A B A B A B A B A
5.5
PE
4A 4A 4A 4A 4A
5EA
116.7
23.8
28
35
102.1
133.2
92.1
84.6
24
1P
23.8
59.9
28.2
49.7
45.6
44.1
22.6
3EB
8
X
32.1
2B 2B 2B 2B 2B
NC
NC
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 123 148 160.5 185.5 198 223 235.5 260.5 273 298 310.5
L4 112.5 137.5 150 175 187.5 212.5 225 250 262.5 287.5 300
L5 15.5 18.5 15.5 18.5 15 18 15 18 14.5 17.5 14.5
271
Plug-in Metal Base SY3000/5000/7000 Series
20
L
53.5
(−) (+) 11 White Red
2- M2.6
20
SOL. a
8 (−) (+) 12 Yellow Red
Station 8 SOL. b
21 (−) (+) 13 Orange Red
SOL. a
9 (−) (+) 14 Yellow Black
Station 9 SOL. b 22 (−) (+) 25 L
SOL. a 15 Pink Black
10 (−) (+) 41 41
Station 10 SOL. b 23 16 Yellow White
(−) (+)
15.2
Standard
D-Sub connector cable assembly (option)
015
AXT100-DS25- 030 (According to MIL-C24308)
050
272
SY3000/5000/7000 Series
1
18 17
16 15
14 13
12 11 Connector terminal no.
10 9
26
25
8 7
Triangle mark indicator position (15.6)
6 5
4 3 L
2 1
Flat ribbon cable connector assembly
Cable Assembly part no.
P: Flat ribbon cable (26 pins) length (L) 26 pins 20 pins 10 pins
<All single wiring> <All double wiring> 1.5 m AXT100-FC26-1 AXT100-FC20-1 AXT100-FC10-1
Terminal no. Terminal no. Polarity 3m AXT100-FC26-2 AXT100-FC20-2 AXT100-FC10-2
SOL.a 1 SOL.a (–) (+) 5m AXT100-FC26-3 AXT100-FC20-3 AXT100-FC10-3
Station 1 1
Station 2
SOL.a 2 Station 1 SOL.b 2 (–) (+) ∗ When using a standard commercial connector, use a 26-pin, 20-pin, or
SOL.a 3 SOL.a 3 (–) (+)
Station 3 10-pin type connector conforming to MIL-C-83503 with strain relief.
Station 4
SOL.a 4 Station 2 SOL.b 4 (–) (+) ∗ Cannot be used for movable wiring
Station 5 SOL.a 5 SOL.a 5 (–) (+) ∗ Lengths other than the above are also available. Please contact SMC
Station 6
SOL.a 6 Station 3 SOL.b 6 (–) (+) for details.
Station 7 SOL.a 7 SOL.a 7 (–) (+)
Station 8 SOL.a 8 Station 4 SOL.b 8 (–) (+) Connector Manufacturer’s Example
Station 9 SOL.a 9 SOL.a 9 (–) (+)
Station 10 SOL.a 10 Station 5 SOL.b 10 (–) (+) • HIROSE ELECTRIC CO., LTD. • Japan Aviation Electronics Industry, Limited
Station 11 SOL.a 11 SOL.a 11 (–) (+) • 3M Japan Limited • J.S.T. Mfg. Co., Ltd.
Station 12 SOL.a 12 Station 6 SOL.b 12 (–) (+) • Fujitsu Limited • Oki Electric Cable Co., Ltd.
13 SOL.a 13 (–) (+)
Station 7 SOL.b 14
14 (–) (+)
15 SOL.a 15 (–) (+) PH: Flat ribbon cable (10 pins)
Station 8 SOL.b 16
16 (–) (+) <All single wiring> <All double wiring>
17 SOL.a 17 (–) (+)
Station 9 SOL.b 18 Terminal no. Terminal no. Polarity
18 (–) (+) SOL.a SOL.a
19 SOL.a 19 (–) (+) Station 1 1 1 (–) (+)
Station 10 SOL.a Station 1 SOL.b
SOL.b 20 (–) (+) Station 2 2 2 (–) (+)
20 SOL.a SOL.a
SOL.a 21 (–) (+) Station 3 3 3 (–) (+)
21 SOL.a Station 2 SOL.b
Station 11 SOL.b 22 Station 4 4 4 (–) (+)
22 (–) (+) SOL.a SOL.a
23 SOL.a 23 (–) (+) Station 5 5 5 (–) (+)
Station 12 SOL.a Station 3 SOL.b
24 SOL.b 24 (–) (+) Station 6 6 6 (–) (+)
Station 7 SOL.a SOL.a 7 (–) (+)
COM. COM. 7
25 25 (+) (–) SOL.a Station 4 SOL.b
COM. 26 COM. Station 8 8 8 (–) (+)
26 (+) (–) COM. COM.
9 9 (+) (–)
Positive Negative COM. 10 COM.
10 (+) (–)
common common
Positive Negative
common common
PG: Flat ribbon cable (20 pins)
<All single wiring> <All double wiring>
Terminal no. Terminal no. Polarity
SOL.a SOL.a (–) (+)
Station 1 1 1
SOL.a Station 1 SOL.b
Station 2 2 2 (–) (+)
SOL.a SOL.a 3 (–) (+)
Station 3 3
SOL.a Station 2 SOL.b
Station 4 4 4 (–) (+)
Station 5 SOL.a SOL.a 5 (–) (+)
5
SOL.a Station 3 SOL.b
Station 6 6 6 (–) (+)
Station 7 SOL.a SOL.a 7 (–) (+)
7
SOL.a Station 4 SOL.b
Station 8 8 8 (–) (+)
Station 9 SOL.a SOL.a 9 (–) (+)
9
SOL.a Station 5 SOL.b 10
Station 10 10 (–) (+)
Station 11 SOL.a SOL.a 11 (–) (+)
11
SOL.a Station 6 SOL.b 12
Station 12 12 (–) (+)
SOL.a 13 (–) (+)
13
Station 7 SOL.b 14
14 (–) (+)
SOL.a 15 (–) (+)
15
Station 8 SOL.b 16
16 (–) (+)
SOL.a 17 (–) (+)
17
Station 9 SOL.b 18
18 (–) (+)
COM. 19 COM.
19 (+) (–)
COM. 20 COM.
20 (+) (–)
Positive Negative
common common
273
274
Type 50
Side Ported Plug-in Metal Base EX510
Type 51
Bottom Ported
SY3000/5000/7000 Series ®
SS5Y 3 50 S5 05 D C6
q w e r t y u i o
q Series w Type t Valve stations
3 SY3000 50 Side ported Symbol Stations Note Symbol Stations Note
5 SY5000 51 Bottom ported 02 2 stations 02 2 stations
All double All single
…
7 SY7000 50R Side ported, External pilot
wiring wiring
∗ External pilot is not available 08 8 stations 12 12 stations
e SI unit output polarity for the bottom-ported type. ∗ This also includes the number of the blanking plate assembly.
—
N
Positive common
Negative common y P, E port entry
U U side∗1 ∗1 Plugs are mounted on the opposite
side of the selected ports.
r Wiring type D
B
D side∗1∗2
Both sides
∗2 Only D side is available for the type
— All double wiring∗1 51 bottom-ported type.
S All single wiring∗2 u A, B port size
∗1 All double wiring: 2-position single, double, 3-position, and 4-position Thread piping
valves can be used on all manifold stations.
∗2 All single wiring: Available only for the manifold which has 2-position
Symbol A, B port SY3000 SY5000 SY7000
single for all stations M5 M5 x 0.8 — —
Note that 2-position double, 3-, or 4-position valves cannot be used. 01 1/8 —
∗ If a mix of single and double wiring is required, it is supplied as a 02 1/4 —
special order. One-touch fitting (Metric)
Symbol A, B port SY3000 SY5000 SY7000
C2 Ø2 — —
C3 Ø 3.2 — —
How to Order Manifold Assembly
Fixed
C4 Ø4 —
C6 Ø6 —
Example (SS5Y3-50S5-) C8 Ø8 —
2-position single (24 VDC) 2-position double (24 VDC)
C10 Ø 10 — —
SY3100-5U1 (3 sets) SY3200-5U1 (1 set)
3-position closed KC2 Ø2 — — Type 50 Type 51
centre (24 VDC) KC3 Ø 3.2 — — (Side ported) (Bottom ported)
SY3300-5U1 (1 set)
KC4
Replaceable
Ø4 —
KC6 Ø6
KC8 Ø8 —
KC10 Ø 10 — —
KC12 Ø 12 — —
ide M∗1 Mixed sizes
Us
P, E port size (Thread piping) 1/8 1/4 3/8
s
n
tio
ta
S
Ø 5/32" —
• For the valve arrangement, the valve closest to the D side is considered the 1st station.
KN7 Ø 1/4"
• Under the manifold part number, state the valves to be mounted in order
starting with the 1st station as shown in the figure above. If the arrangement KN9 Ø 5/16" —
becomes too complicated, specify the details on a manifold specification sheet. KN11 Ø 3/8" — —
∗ When mixing top-ported configurations, select from those listed on page 285. In such M∗1 Mixed sizes
cases, use caution as there is also output on the A and B ports on the base side.
P, E port size (Thread piping) 1/8 1/4 3/8
Specify on the manifold specification sheet if plugs are required for the A and B ports
on the base side. ∗1 When ports are of mixed sizes, indicate the piping specifications on the manifold specification sheet.
275
Plug-in Metal Base SY3000/5000/7000 Series
…
than that of the standard
D12 For 12 stations rail. the SMC website, https://www.smc.eu
∗ Only direct mounting is available for the type
51 bottom-ported type.
∗ Refer to page 319 for the fixation of DIN rail
mounting type manifold.
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 0 0 5 1
!0 Manual override
q w e r t y u i o !0 !1 —: D:
Non-locking Push-turn
Base mounted push type locking
slotted
q Series y Pilot valve option type
3 SY3000 — Standard (0.7 MPa)
5 SY5000 B Quick response type (0.7 MPa)
7 SY7000 K∗1 High pressure type (1.0 MPa)
E: F:
∗1 Only the metal seal type is available for the
Push-turn Slide locking
w Type of actuation high pressure type.
locking lever type
1
2-position
Single u Coil type type
2 Double
— Standard
3 Closed centre
T With power saving circuit (Continuous duty type)
4 3-position Exhaust centre
5 Pressure centre ∗ Be sure to select the power saving circuit
type if the valve is to be continuously ∗ Refer to page 36 for the safety slide locking
A∗1 N.C./N.C. energised for long periods of time.
4-position manual override.
B∗1 dual 3-port
N.O./N.O. ∗ Be careful of the energising time when the
C∗1 N.C./N.O. power saving circuit is selected. Refer to page
∗1 Only the rubber seal type is available for the
316 for details. !1 Type of mounting screw
i Rated voltage —
4-position dual 3-port valve. Round head combination screw
B Hexagon socket head cap screw
5 24 VDC
e Seal type K
H
Round head combination screw (Drop prevention type)
Hexagon socket head cap screw (Drop prevention type)
0 Rubber seal o Light/surge voltage suppressor ∗ For “K” and “H,” the valve body cover has a
1 Metal seal and common specification drop prevention construction to stop the
Surge voltage Common mounting screws from falling out when the
r Pilot type
Symbol With light valve is removed for maintenance, etc.
suppressor specification
∗ When ordering a valve individually, the
— Internal pilot R —
base gasket is not included.
Non-polar
R External pilot U Since the base gasket is attached to the
S — manifold, please order the base gasket
Positive common separately if it is needed for maintenance.
Z
t Back pressure check valve NS — Refer to page 290 for base gasket and
(Built-in valve type) Negative common mounting screw part numbers.
NZ ∗ “B” and “H” cannot be selected for the
— None
∗ For the non-polar type, be careful of surge individual SUP/EXH spacer assembly,
H Built-in voltage intrusion. Refer to page 317 for details. interface regulator, or double check spacer
∗ Only the rubber seal type is available. ∗ Only “Z” and “NZ” types are available with a assembly with residual pressure release valve.
∗ The back pressure check valve is not available power saving circuit. Select “R,” “U,” “S,” or “Z”
for the 3-position type or the SY7000. for the valve when the SI unit output polarity is
— (positive common). Select “R,” “U,” “NS,” or
“NZ” for the valve when the SI unit output Protective class
polarity is N (negative common). class # (Mark: )
276
SY3000/5000/7000 Series
Plug-in Type 50/Side Ported
U M5
SS5Y3-50(R)S5- Stations D - KC
C, N (D)
, KN B
(Station 1) ---(Station n)
50RS5- Stations UD
manual override)
(Slide locking
68.3
65.6
62.6
2B 2B
3
7.1
32
22.6
4A 4A [Plug for external pilot]
2B
4A
7.5
11.8
C4, C6: 6.6 [4(A), 2(B) port]
Applicable tube O.D.: Ø 2
C2, C3: 42.4 (Pitch) : Ø 3.2, Ø 1/8" ∗ The above drawing shows when P,
C4, C6: 41.8 P = 10.5 : Ø 4, Ø 5/32" E port entry is D.
: Ø 6, Ø 1/4"
D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override
(Pitch)
DIN rail holding screw
45.1 P = 10.5 (
Push-turn locking slotted type:
Press, then rotate it. ) M5 x 0.8 (External pilot)
18.5 19.6 Light/surge 4(A) port side : Blue (For rubber seal)
(For DIN rail mounting) [Pilot EXH port]
voltage : Grey (For metal seal)
DIN rail bracket mounting screw suppressor 2(B) port side : Yellow
(For DIN rail mounting)
DIN rail
B A B A B A B A B A
92.7
5EA
14 A 14 A 14 A 14 A 14 A
89
PE
16.8 17.2
15.9 16.2
79
5.5
64.4
35
56.9
21.8 16
1P
29.8
X
26.6
12 B 12 B 12 B 12 B 12 B
3EB
2B 2B
7.1
7.1
32
32
22.6
22.6
4A 4A
One-touch fitting
M5 x 0.8 [4(A), 2(B) port]
[4(A), 2(B) port] Applicable tube O.D.: Ø 2
6.6 (Pitch)
(Pitch) : Ø 3.2, Ø 1/8"
41.8 P = 10.5 : Ø 4, Ø 5/32"
48.4 P = 10.5
: Ø 6, Ø 1/4"
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17
277
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 50/Side Ported
U
SS5Y3-50(R)S5- Stations D -01(D)
B
manual override)
(Slide locking
68.3
3
65.6
62.6
2B 2B [Plug for external pilot]
7.1
2B
32
22.6
4A 4A
4A
mounting)
(Pitch) 1/8
7.5
P = 12.5
11.8
41.8 [4(A), 2(B) port]
∗ The above drawing shows when P,
E port entry is D.
D side U side
L3
5.3 L4
(DIN rail mounting hole pitch: 12.5) Manual override
M5 x 0.8 (External pilot)
DIN rail
B A B A B A B A B A
92.7
5EA
14 A 14 A 14 A 14 A 14 A
89
PE
16.8 17.2
15.9 16.2
79
5.5
64.4
35
56.9
21.8 16
1P
29.8
X
26.6
12 B 12 B 12 B 12 B 12 B
3EB
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 76 88.5 101 113.5 126 138.5 151 163.5 176 188.5 201
L2 68 80.5 93 105.5 118 130.5 143 155.5 168 180.5 193
L3 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5
L4 100 112.5 125 137.5 150 162.5 175 187.5 200 212.5 225
L5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5 17.5
278
SY3000/5000/7000 Series
Plug-in Type 50/Side Ported
U 01
SS5Y5-50(R)S5- Stations D - KC
C, N (D)
, KN B
(Station 1)----------- (Station n)
50RS5- Stations UD
manual override)
(Slide locking
3
74.3
71.6
68.6
2B 2B 2B
7.8
38
27.3
4A 4A 4A
10
mounting)
(Pitch) One-touch fitting
∗ The above drawing shows when P,
14.3
45.8 P = 16 [4(A), 2(B) port] E port entry is D.
Applicable tube O.D.: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16"
D side U side
L3
DIN rail 5.3 L4 M5 x 0.8 (External pilot)
Manual override
holding screw (DIN rail mounting hole pitch: 12.5) [Pilot EXH port]
(For DIN
rail mounting) 50
(Pitch)
P = 16
( Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
DIN rail bracket 20.5 19.6 Light/surge voltage : Grey (For metal seal)
mounting screw suppressor 2(B) port side : Yellow
(For DIN
rail mounting)
DIN rail
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
PE
5EA
106.2
5.5
116.6
23.2
35
96.2
20
81.6
74.1
20
1P
24.6
20
43.8
40.2
3EB
30.2
X
12 B 12 B 12 B 12 B 12 B
4 x Ø 4.5
)Replaceable: 8.5
SI unit 12.3
(For mounting)
5 L2 18 M5 x 0.8 (External pilot)
Fixed: 4.9
2B 2B
7.8
9.8
38
38
27.3
27.3
4A 4A
One-touch fitting
8.4 1/8 [4(A), 2(B) port]
(Pitch) Applicable tube O.D.: Ø 4, Ø 5/32"
[4(A), 2(B) port]
45.8 P = 16
(Pitch) : Ø 6, Ø 1/4"
51.6 P = 16 : Ø 8, Ø 5/16"
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5
279
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 50/Side Ported
U
SS5Y5-50(R)S5- Stations D -02(D)
B
manual override)
(Slide locking
3
[Plug for external pilot]
74.3
71.6
68.6
2B 2B 2B
9.8
38
27.3
4A 4A 4A
10
8.4
mounting)
(Pitch) 1/4
14.3
45.8 P = 17.5 [4(A), 2(B) port] E port entry is D.
D side U side
L3
M5 x 0.8 (External pilot)
5.3 L4
Manual override [Pilot EXH port]
(DIN rail mounting hole pitch: 12.5)
DIN rail holding screw
(For DIN rail mounting)
50
(Pitch)
P = 17.5
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
20.5 19.6 Light/surge voltage : Grey (For metal seal)
DIN rail bracket mounting screw suppressor
(For DIN rail mounting) 2(B) port side : Yellow
DIN rail
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
PE
5EA
106.2
5.5
23.2
116.6
35
96.2
20
81.6
74.1
20
1P
24.6
20
43.8
40.2
3EB
8
30.2
X
12 B 12 B 12 B 12 B 12 B
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 88.5 106 123.5 141 158.5 176 193.5 211 228.5 246 263.5
L2 78.5 96 113.5 131 148.5 166 183.5 201 218.5 236 253.5
L3 123 135.5 148 173 185.5 210.5 223 235.5 260.5 273 298
L4 112.5 125 137.5 162.5 175 200 212.5 225 250 262.5 287.5
L5 17.5 15 12.5 16 13.5 17.5 15 12.5 16 13.5 17.5
280
SY3000/5000/7000 Series
Plug-in Type 50/Side Ported
U 02
SS5Y7-50(R)S5- Stations D - KC
C, N (D)
, KN B
78.3
78.1
84
2B 2B 2B
44.5
9.4
32.4
4A 4A 4A
10
(Pitch)
mounting)
∗ The above drawing shows when P,
14.3
46.6 P = 19
E port entry is D.
One-touch fitting
[4(A), 2(B) port]
Applicable tube O.D.: Ø 8, Ø 5/16"
: Ø 10, Ø 3/8"
∗: These figures show the “SS5Y7-50S5-05B-C10”.
D side U side
L3
5.3 L4 Manual override
(DIN rail mounting hole pitch: 12.5)
(Pitch) (
Push-turn locking slotted type:
Press, then rotate it. )
DIN rail holding screw 52 P = 19 4(A) port side : Blue (For rubber seal)
(For DIN rail mounting) 20.5 19.6 (Light/surge voltage : Grey (For metal seal) M5 x 0.8 (External pilot)
suppressor) 2(B) port side : Yellow PE: Pilot EXH port
DIN rail bracket mounting screw
(For DIN rail mounting)
(DIN rail)
BA BA BA BA B A
5.5
PE
14 A 14 A 14 A 14 A 14 A
5EA
116.7
23.8
28
35
102.1
133.2
92.1
84.6
24
1P
23.8
28.2
49.7
44.1
3EB
8
X
32.1
12 B 12 B 12 B 12 B 12 B
NC
NC
4 x Ø 4.5
SI unit
(5.4)
2B 2B
44.5
44.5
10.3
9.4
32.4
31.5
4A 4A
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 123 148 160.5 185.5 198 223 235.5 260.5 273 298 310.5
L4 112.5 137.5 150 175 187.5 212.5 225 250 262.5 287.5 300
L5 15.5 18.5 15.5 18.5 15 18 15 18 14.5 17.5 14.5
281
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 51/Bottom Ported
M5, 01
SS5Y3-51S5- Stations D- CKC, N,
KN
(Pitch)
46.4 P = 10.5
4 x M4 x 0.7, thread depth 4 One-touch fitting
23.6
(For mounting) [4(A), 2(B) port]
Applicable tube O.D.: Ø 2
21.1
29.8
3EB 2B 2B
: Ø 3.2, Ø 1/8"
16.8 16.8
: Ø 4, Ø 5/32"
56.4
1P
: Ø 6, Ø 1/4"
Cut dimensions for panel mounting 5EA 4A 4A
C2, C3, C4 : 16
: 15
1/8
C6
4
(For 9 stations or more)
(For 9 stations or more) L2
40
(For 9 stations or more)
manual override)
(Slide locking
4 x Ø 4.5
52.4
68.3
56.4
65.6
62.6
4 x M4 x 0.7
32
4 x Ø 4.5
4 4
(4.1)
(Station 1) ---(Station n) L3
L2
(Pitch)
45.1 P = 10.5 Manual override ∗: These figures show the
D side U side
18.5 19.6 Light/surge voltage
suppressor (Push-turn locking slotted type:
Press, then rotate it. ) “SS5Y3-51S5-05D-C6”.
B A B A B A B A B A
92.7
89
14 A 14 A 14 A 14 A 14 A
64.4
56.9
21.8 16
12 B 12 B 12 B 12 B 12 B
SI unit
(Max. 3) L1
17 20.1
14 21.1
29.8
29.8
29.8
1P 1P 1P
32
32
)
C6: 12.8
N7: 16.6
(
282
SY3000/5000/7000 Series
Plug-in Type 51/Bottom Ported
01, 02
SS5Y5-51S5- Stations D - CKC, N,
KN
2 x M4 x 0.7
4 x M4 x 0.7, (For 9 stations or more)
50 (Pitch)
thread depth 5 P = 16
24
(For mounting) One-touch fitting
[4(A), 2(B) port]
3EB 2B 2B
40.2
“SS5Y5-51S5-05D-C8”.
71.6
1P : Ø 8, Ø 5/16"
20
5EA 4A 4A
5
(Station 1) ----------- (Station n)
4 x Ø 4.5
20 25.2
manual override)
(Slide locking
61.6
71.6
74.3
71.6
68.6
4 x M4 x 0.7
38
4 x Ø 4.5
5 5
L3
(4.9)
(Pitch) L2
50 P = 16
Light/surge U side Manual override
20.5 19.6
D side voltage suppressor
(
Push-turn locking slotted type:
Press, then rotate it. )
4(A) port side : Blue (For rubber seal)
: Grey (For metal seal)
B A B A B A B A B A 2(B) port side : Yellow
14 A 14 A 14 A 14 A 14 A
106.2
116.6
81.6
74.1
20
30.2
12 B 12 B 12 B 12 B 12 B
4 x Ø 4.5
SI unit
(For mounting)
(Max. 3) L1
Port size 01 Port size 02 One-touch fitting (Replaceable)
(Pitch) (Pitch) (Pitch)
50 P = 16 50 P = 17.5 50 P = 16
17.5
14.5
3EB 2B
14.8
3EB 2B
9.7
40.2
40.2
40.2
3EB 2B
1P 1P 1P
38
38
(15.5)
283
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 51/Bottom Ported
02
SS5Y7-51S5- Stations D- CKC, N,
KN
(D)
Port size 02 One-touch fitting (Replaceable)
(For Ø 12)
(For mounting)
(29.5)
3/8
[1(P), 5(EA), 3(EB) port]
(Pitch) M4 x 0.7 thread depth 5
(Max. 3) 52 P = 19
(For 9 stations or more)
27
Fitting dimensions for panel mounting
(17.6)
5
2B 2B
46.1
3EB
23
81.1
One-touch fitting
22
1P
[4(A), 2(B) port]
23
32.8
33.1
L3 C10: Ø 10 3EB 2B 3EB 2B
5 L2 N9 : Ø 5/16"
N11: Ø 3/8"
22.6
22
L1 1P 1P
5EA 4A 5EA 4A
(Station 1) (Station n)
(Slide locking manual override)
4 x Ø 4.5 2 x Ø 4.5
84
27.1
(5.4)
81.1
72.1
24
4 x M4 x 0.7
4 x Ø 4.5
5 5
D side U side L3
Manual override
L2
(Light/surge voltage suppressor) (
Push-turn locking slotted type:
Press, then rotate it. )
(Pitch) 4(A) port side : Blue (For rubber seal)
52 P = 19 : Grey (For metal seal)
20.5 19.6 2(B) port side : Yellow
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
116.7
133.2
92.1
84.6
24
32.1
12 B 12 B 12 B 12 B 12 B
NC
NC
SI unit 4 x Ø 4.5
(For mounting)
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 — — — — — — — 107.5 117 126.5 136
284
Plug-in Metal Base EX510
Type 52
Top Ported
SY3000/5000/7000 Series ®
SS5Y 3 52 S5 05 D
q w e r t y u i
q Series r Wiring type t Valve stations
3 SY3000 — All double wiring∗1 Symbol Stations Note
5 SY5000 S All single wiring∗2 02 2 stations
All double
…
7 SY7000 ∗1 All double wiring: 2-position single, double, wiring
3-position, and 4-position valves can be used 08 8 stations
on all manifold stations. 02 2 stations
All single
∗2 All single wiring: Available only for the manifold
…
w Type which has 2-position single for all stations 12 12 stations
wiring
…
tio
285
Plug-in Metal Base SY3000/5000/7000 Series
How to Order Valves (With mounting screw) Refer to page 17 for valve specifications.
SY 3 1 3 0 5 1 C6
q w e r t y u i o !0 !1 !2 !3
Top ported
1 Single power saving circuit is selected. Refer to page One-touch fitting (Metric)
2-position 316 for details. Symbol A, B port SY3000 SY5000 SY7000
2 Double
3 Closed centre C2 Ø2 — —
C3
i Rated voltage
4 3-position Exhaust centre Ø 3.2 — —
5 Pressure centre C4 Ø4 —
5 24 VDC C6 Ø6
A∗1 4-position N.C./N.C.
B∗1 dual N.O./N.O. C8 Ø8 —
C∗1 3-port N.C./N.O. o Light/surge voltage suppressor C10
C12
Ø 10
Ø 12
—
—
—
—
∗1 Only the rubber seal type is available and common specification
for the 4-position dual 3-port valve. One-touch fitting (Inch)
Surge voltage Common
Symbol With light Symbol A, B port SY3000 SY5000 SY7000
suppressor specification
e Seal type R —
Non-polar
N1
N3
Ø 1/8"
Ø 5/32"
—
—
—
U
0 Rubber seal N7 Ø 1/4"
S — Positive
1 Metal seal N9 Ø 5/16" —
Z common
NS — Negative N11 Ø 3/8" — —
r Pilot type NZ common
— Internal pilot ∗ For the non-polar type, be careful of surge
voltage intrusion.
!2 Thread type
R External pilot
— Rc
Refer to page 317 for details.
∗ Only “Z” and “NZ” types are available with a F G
t Back pressure check valve power saving circuit. Select “R,” “U,” “S,” or
“Z” for the valve when the SI unit output
N
T
NPT
NPTF
(Built-in valve type) polarity is — (positive common). Select “R,”
∗ Only — is available for M5.
— None “U,” “NS,” or “NZ” for the valve when the SI
H Built-in unit output polarity is N (negative common).
∗ Only the rubber seal type is available. !3 Type of mounting screw
∗ The back pressure check valve is not
available for the 3-position type or the
!0 Manual override — Round head combination screw
B Hexagon socket head cap screw
SY7000. —: D:
Non-locking Push-turn K Round head combination screw (Drop prevention type)
y Pilot valve option push type locking H Hexagon socket head cap screw (Drop prevention type)
— Standard (0.7 MPa) slotted ∗ For “K” and “H,” the valve body cover has a
B Quick response type (0.7 MPa) type drop prevention construction to stop the
K∗1 High pressure type (1.0 MPa) mounting screws from falling out when the
valve is removed for maintenance, etc.
∗1 Only the metal seal type is available ∗ When ordering a valve individually, the
for the high pressure type. base gasket is not included.
E: F: Since the base gasket is attached to the
Push-turn Slide locking manifold, please order the base gasket
locking lever type separately if it is needed for maintenance.
type Refer to page 290 for base gasket and
mounting screw part numbers.
∗ “B” and “H” cannot be selected for the
individual SUP/EXH spacer assembly or
interface regulator.
∗ Refer to page 36 for the safety slide locking
manual override.
Protective class
class # (Mark: )
286
SY3000/5000/7000 Series
Plug-in Type 52/Top Ported
U
SS5Y3-52(R)S5- Stations D -(D)
B
52RS5- Stations UD
(Station 1)---(Station n)
N7: 80.6 )
76.8
[Plug for external pilot]
mounting)
(C6:
11.8
32
∗ The above drawing shows when P,
7.5
E port entry is D.
D side U side
L3
DIN rail 5.3 L4
holding screw (DIN rail mounting hole pitch: 12.5) Manual override M5 x 0.8 (External pilot)
[Pilot EXH port]
(For DIN
rail mounting) 45.1
(Pitch)
P = 10.5 (
Push-turn locking slotted type:
Press, then rotate it. ) 68.3
18.5 19.6 Light/surge voltage 4(A) port side : Blue (For rubber seal) (Slide locking manual override)
DIN rail bracket : Grey (For metal seal)
mounting screw suppressor
2(B) port side : Yellow
(For DIN
rail mounting)
DIN rail
B A B A B A B A B A
92.7
4A 4A 4A 4A 4A
5EA
89
PE
16.8 17.2
15.9 16.2
79
5.5
64.4
35
56.9
21.8 16
1P
29.8
X
26.6
2B 2B 2B 2B 2B
3EB
4 x Ø 4.5 SI unit 8 8.6
(For mounting) One-touch fitting 14.5
4 L2
[4(A), 2(B) port]
(L5) L1 22.1
Applicable tube O.D.: Ø 2
: Ø 3.2, Ø 1/8" 28
M5 x 0.8
: Ø 4, Ø 5/32"
[4(A), 2(B) port] 1/8
: Ø 6, Ø 1/4"
[1(P), 5(EA), 3(EB) port]
M5 x 0.8 (External pilot)
[External pilot port]
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 71.5 82 92.5 103 113.5 124 134.5 145 155.5 166 176.5
L2 63.5 74 84.5 95 105.5 116 126.5 137 147.5 158 168.5
L3 98 110.5 123 135.5 148 160.5 160.5 173 185.5 198 210.5
L4 87.5 100 112.5 125 137.5 150 150 162.5 175 187.5 200
L5 13.5 14.5 15.5 16.5 17.5 18.5 13 14 15 16 17
287
Plug-in Metal Base SY3000/5000/7000 Series
Plug-in Type 52/Top Ported
U
SS5Y5-52(R)S5- Stations D -(D)
B
(86.7)
[Plug for external pilot]
72.3
71.6
10
E port entry is D.
D side U side
DIN rail L3
holding screw 5.3 L4
(For DIN M5 x 0.8 (External pilot)
(DIN rail mounting hole pitch: 12.5) Manual override
rail mounting) [Pilot EXH port]
(Pitch)
50 P = 16 (Push-turn locking slotted type:
Press, then rotate it. ) 74.3
DIN rail bracket 20.5 19.6 4(A) port side : Blue (For rubber seal) (Slide locking
mounting screw Light/surge voltage : Grey (For metal seal) manual override)
(For DIN suppressor 2(B) port side : Yellow 68.6
rail mounting)
01 : 16.2
C : 14.5
DIN rail
5.5
B A B A B A B A B A
4A 4A 4A 4A 4A
PE
5EA
106.2
23.2
116.6
35
96.2
20
81.6
74.1
20
1P
24.6
20
43.8
40.2
40.2
3EB
30.2
X
2B 2B 2B 2B 2B 8
1/8 12.3
4 x Ø 4.5 SI unit [4(A), 2(B) port] 18
(For mounting) One-touch fitting
5 L2 28
[4(A), 2(B) port]
(L5) L1 Applicable tube O.D.: Ø 4, Ø 5/32" 34
: Ø 6, Ø 1/4" 1/4
: Ø 8, Ø 5/16"
[1(P), 5(EA), 3(EB) port]
M5 x 0.8 (External pilot)
[External pilot port]
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 84 100 116 132 148 164 180 196 212 228 244
L2 74 90 106 122 138 154 170 186 202 218 234
L3 110.5 135.5 148 160.5 173 198 210.5 223 248 260.5 273
L4 100 125 137.5 150 162.5 187.5 200 212.5 237.5 250 262.5
L5 13.5 18 16 14.5 12.5 17 15.5 13.5 18 16.5 14.5
288
SY3000/5000/7000 Series
Plug-in Type 52/Top Ported
U
SS5Y7-52(R)S5- Stations D -(D)
B
(Station 1) (Station n)
52RS5- Stations UD
(110.3)
[Plug for external pilot]
(98.4)
87
78.1
44.5
mounting)
∗ The above drawing shows when P,
14.3 E port entry is D.
D side U side
L3
5.3 L4 Manual override
M5 x 0.8 (External pilot)
(DIN rail mounting hole pitch: 12.5)
(Push-turn locking slotted type:
Press, then rotate it. ) PE: Pilot EXH port
DIN rail holding screw (Pitch) 4(A) port side : Blue (For rubber seal)
52 P = 19 : Grey (For metal seal) 84
(For DIN rail mounting)
(Light/surge voltage 2(B) port side : Yellow (Slide locking 78.3
20.5 19.6 manual override)
DIN rail bracket mounting screw suppressor)
(For DIN rail mounting)
(DIN rail) B A B A B A B A B A
5.5
PE
4 A 4 A 4 A 4 A 4 A
5EA
116.7
23.8
28
102.1
35
133.2
92.1
84.6
24
1P
23.8
28.2
49.7
45.6
44.1
22.6
3EB
8
X
32.1
2B 2B 2B 2B 2B
NC
NC
n: Stations 2 3 4 5 6 7 8 9 10 11 12
L1 92 111 130 149 168 187 206 225 244 263 282
L2 82 101 120 139 158 177 196 215 234 253 272
L3 123 148 160.5 185.5 198 223 235.5 260.5 273 298 310.5
L4 112.5 137.5 150 175 187.5 212.5 225 250 262.5 287.5 300
L5 15.5 18.5 15.5 18.5 15 18 15 18 14.5 17.5 14.5
289
SY3000/5000/7000 Series Type 50, 51, 52
Plug-in Metal Base Manifold Exploded View
Holding screw
Part no.
No. Description Note
SY3000 SY5000 SY7000
Round head SY3000-23-24A SY5000-221-1A SY7000-221-1A
Part numbers shown on the left are
Valve mounting combination screw (M2 x 32) (M3 x 32.5) (M3 x 36.5)
q screw
for 10 valves (20 pcs.).
Hexagon socket SY3000-222-1A SY5000-222-1A SY7000-222-1A (30 pcs. for the SY7000)
head cap screw (M2 x 32) (M3 x 32.5) (M3 x 36.5)
Base gasket Part numbers shown on the left are
w SY30M-11-1A SY50M-11-1A SY70M-11-1A for 10 valves (10 pcs.).
(for plug-in metal base and sub-plate)
e DIN rail VZ1000-11-1- VZ1000-11-4- VZ1000-11-4- Refer to page 292.
Clamp bracket assembly Part numbers shown on the left are for the clamp bracket
r SY30M-15-2A SY50M-15-2A SY70M-15-2A assembly for one manifold (two sets of clamp brackets).
(for plug-in metal base)
290
SY3000/5000/7000 Series
One-touch Fitting, Plug Assembly Part Nos.
Refer to “How to Replace One-touch Fittings” on page 300 for the replacement method.
One-touch fittings
Port size SY3000 SY5000 SY7000
Ø2 VVQ1000-50A-C2 — —
Ø 3.2 VVQ1000-50A-C3 — —
Metric size
Ø4 VVQ1000-50A-C4 VVQ1000-51A-C4 —
Ø6 Straight type VVQ1000-50A-C6 VVQ1000-51A-C6 VVQ2000-51A-C6
Ø8 — VVQ1000-51A-C8 VVQ2000-51A-C8
A, B port
Ø 10 — — VVQ2000-51A-C10
Ø 12 — — KQ2H12-17-X224
Ø 1/8" VVQ1000-50A-N1 — —
Inch size
Plug assembly
SY3000 SY5000 SY7000
A, B port VVQ0000-58A VVQ1000-58A VVQ2000-58A
∗ Purchasing order is available in units of 10 pieces.
291
SY3000/5000/7000 Series
Manifold Options
For the SY3000 Plug-in metal base
VZ1000-11-1-
∗ After confirming the L3 dimension in the dimensions table of each series, refer to the DIN rail dimensions table below and
specify the number in the box .
L
(7.5) 8
5.5
(35)
(25)
No. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
L dimension 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 273 285.5 298 310.5 323
Weight [g] 17.6 19.9 22.1 24.4 26.6 28.9 31.1 33.4 35.6 37.9 40.1 42.4 44.6 46.9 49.1 51.4 53.6 55.9 58.1
No. 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
L dimension 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 523 535.5 548 560.5
Weight [g] 60.4 62.5 64.9 67.1 69.4 71.6 73.9 76.1 78.4 80.6 82.9 85.1 87.4 89.6 91.9 94.1 96.4 98.6 100.9
No. 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56
L dimension 573 585.5 598 610.5 623 635.5 648 660.5 673 685.5 698 710.5 723 735.5 748 760.5 773 785.5 798
Weight [g] 103.1 105.4 107.6 109.9 112.1 114.4 116.6 118.9 121.1 123.4 125.6 127.9 130.1 132.4 134.6 136.9 139.1 141.4 143.6
No. 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71
L dimension 810.5 823 835.5 848 860.5 873 885.5 898 910.5 923 935.5 948 960.5 973 985.5
Weight [g] 145.9 148.1 150.4 152.6 154.9 157.1 159.4 161.6 163.9 166.1 168.4 170.6 172.9 175.1 177.4
No. 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
L dimension 98 110.5 123 135.5 148 160.5 173 185.5 198 210.5 223 235.5 248 260.5 273 285.5 298 310.5 323
Weight [g] 24.8 28 31.1 34.3 37.4 40.6 43.8 46.9 50.1 53.3 56.4 59.6 62.7 65.9 69.1 72.2 75.4 78.6 81.7
No. 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
L dimension 335.5 348 360.5 373 385.5 398 410.5 423 435.5 448 460.5 473 485.5 498 510.5 523 535.5 548 560.5
Weight [g] 84.9 88 91.2 94.4 97.5 100.7 103.9 107 110.2 113.3 116.5 119.7 122.8 126 129.2 132.3 135.5 138.6 141.8
No. 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56
L dimension 573 585.5 598 610.5 623 635.5 648 660.5 673 685.5 698 710.5 723 735.5 748 760.5 773 785.5 798
Weight [g] 145 148.1 151.3 154.5 157.6 160.8 163.9 167.1 170.3 173.4 176.6 179.8 182.9 186.1 189.2 192.4 195.6 198.7 201.9
No. 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71
L dimension 810.5 823 835.5 848 860.5 873 885.5 898 910.5 923 935.5 948 960.5 973 985.5
Weight [g] 205.1 208.2 211.4 214.5 217.7 220.9 224 227.2 230.4 233.5 236.7 239.8 243 246.2 249.3
292
SY3000/5000/7000 Series
Manifold Options
Blanking plate assembly (With mounting screw)
Used when valve additions are expected or for maintenance
A structure is in place on the blanking plate to prevent the mounting screws from sliding.
SY 0M 26 2 A
Series
3 SY3000 Option for mounting
5 SY5000 With mounting screw
—
7 SY7000 (Round head combination screw)
With mounting screw
B (Hexagon socket head cap screw)
(A) (B)
4 2 Base type
2 For plug-in metal base
5 1 3
(EA) (P) (EB)
Circuit diagram
Plug Dimensions
These are inserted in unused cylinder Applicable fitting size Applicable fitting size
Ø d (Metric size)
Model A L ØD
Ø d (Inch size)
Model A L ØD
ports and P, E ports.
Ød
293
Manifold Options SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options ∗ Refer to pages 300 to 302 for dimensions. M3: 0.8 N·m (SY5000/7000)
Individual SUP spacer assembly How to Order Individual SUP/EXH Spacer Assembly
[With a connector gasket, a base gasket, and two mounting One-touch fitting
screws (3 pcs. for the SY7000)] Straight type SY 3 0M 38 1 A C6
When the same manifold is used for different pressures, an
individual SUP spacer assembly is used as a supply port for One-touch fitting
different pressures. Elbow type SY 3 0M 38 2 A L6
∗ When selecting a One-touch fitting elbow type for a spacer Series
assembly, use it faced upward, since it interferes with A and B
port piping of Type 50 manifolds. 3 SY3000
5 SY5000
7 SY7000
294
SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options ∗ Refer to pages 300 to 302 for dimensions. M3: 0.8 N·m (SY5000/7000)
[How to mount SUP stop valve spacer assembly with residual Valve mounting screw (See page 198.)
Tightening torque:
pressure release valve] SY3000 series: 0.16 N·m
Insert the SUP stop valve mounting screw from the side of the spacer assembly, SY5000/7000 series: 0.8 N·m
and mount it to the manifold. For Hexagon socket head cap screws
Tighten the SUP stop valve mounting screw to the specified tightening torque. Nominal wrench size:
Mount the valve and tighten the valve mounting screws to the specified SY3000 series: 1.5
tightening torque after mounting the SUP stop valve spacer assembly with SY5000/7000 series: 2.5 Valve
residual pressure exhaust valve.
SUP stop valve spacer assembly
∗ Install the plate type nut to the spacer assembly as shown in the figure if it with residual pressure release valve
comes off. The SUP stop valve mounting screws can be tightened with a Plate type nut
hexagon wrench without removing the plate type nut. SY3000 series:
∗ This product is only for internal pilot specifications, as the external pilot air SY30M-57-1A (10 pcs. included) Hexagon wrench
cannot be shut off. SY5000/7000 series: Nominal wrench size:
∗ If the product is equipped with a 3-position closed centre, residual pressure SY50M-57-1A (10 pcs. included) SY3000 series: 1.3
cannot be released, so use in combination with a 3-port valve, which can be SY5000/7000 series: 2
SUP stop valve mounting screw
connected to the A, B piping port.
Tightening torque:
SY3000 series: 0.16 N·m
SY5000/7000 series: 0.8 N·m
295
Manifold Options SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options ∗ Refer to pages 300 to 302 for dimensions. M3: 0.8 N·m (SY5000/7000)
Specifications
Max. operating pressure 1.0 MPa
Min. operating pressure 0.1 MPa
Ambient and fluid temperatures –10 to 50 °C
SY3000 0.3 dm3/(s·bar)
Flow rate
characteristics: C
SY5000 0.7 dm3/(s·bar)
SY7000 1.1 dm3/(s·bar)
Max. operating frequency 3 Hz
296
SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options ∗ Refer to pages 300 to 302 for dimensions. M3: 0.8 N·m (SY5000/7000)
Interface regulator
[With a connector gasket, a base gasket, and two mounting screws (3 pcs. for the SY7000)]
Used when the supply pressure for each valve on the same manifold must be individually set (reduced pressure)
How to Order
SY 3 0M 05 P
Series Applicable valve∗3
3 SY3000 — For single, double, and 4-position
3 For 3-position
Pressure gauge option∗1 ∗1 In the case of the SY3000 series with a pressure gauge, when mounting on the manifold, use
M1 Without pressure gauge caution that the part numbers are different between the odd no. stations and the even no. stations
05 Pressure gauge with MPa display (For odd number station) to prevent the pressure gauges from interfering with each other.
06 Pressure gauge with MPa display (For even number station) ∗2 As per the new Measurement Law, gauges with a psi display will only be sold to overseas
customers.
N5 Pressure gauge with psi display (For odd number station)∗2
∗3 In the case of the SY3000 series, use caution that the part numbers will differ depending on the
N6 Pressure gauge with psi display (For even number station)∗2 one for single/double and 4- and 3-position due to the different length of solenoid valves. Also, if
you have selected a model with a pressure gauge, and if at least the one for 3-position is included
in the same manifold, use all the ones for 3-position to prevent the pressure gauges from
SY 5 0M 00 P interfering with each other.
Mounting screw
Base gasket
Connector gasket
Specifications
Interface regulator model SY30M--- SY50M-- SY70M-- ∗1 3-position closed centre and pressure centre, and 4-position
Applicable valve model∗1 SY3 03 (R) SY5 03 (R) SY7 03 (R) dual 3-port valves are only available for 1(P) port pressure
regulation.
Regulating port 1(P), 4(A), 2(B)
∗2 Gasket and mounting screws are included in the weight.
Set pressure range 0.1 to 0.7 MPa ∗3 ( ): Denotes the values of SY30M---3
Maximum operating pressure 1.0 MPa ∗ Always apply pressure from 1(P) port in the base for interface
Fluid Air regulator.
Ambient and fluid temperatures –10 to 50 °C (No freezing) ∗ When using in combination with the SY 57 30 01 -1-E (With
With pressure gauge 33 (35)∗3 75 93 residual pressure release valve), the length of the required
Weight [g]∗2 mounting screws will differ. Please contact SMC for details.
Without pressure gauge 27 (29)∗3 69 87
(EA)5 3(EB)
(EA)5 3(EB) (EA)5 3(EB)
297
Manifold Options SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options: Spacer Combinations and Screw List q M3: 0.8 N·m (SY5000/7000)
q
q SY3000 (M2) w
w SY5000 (M3) e
e SY7000 (M3)
Combination
Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw
<Round head combination screw> SY3000- SY3000- SY5000- SY5000- SY7000- SY7000-
q: SY3000-23-24A A Valve 23-24A 222-1A 221-1A 222-1A 221-1A 222-1A
[for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves
w: SY5000-221-1A
(20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)] (30 pcs.)] (30 pcs.)]
e: SY7000-221-1A
<Hexagon socket head cap screw> SUP stop valve
A q: SY3000-222-1A spacer assembly
w: SY5000-222-1A B with residual
B e: SY7000-221-1A pressure
release valve SY30M-56-2A SY50M-56-2A SY70M-56-2A
q: SY30M-56-2A
C (2 pcs.) (2 pcs.) (3 pcs.)
w: SY50M-56-2A Individual
e: SY70M-56-2A SUP (EXH)
C
spacer
assembly
A Valve
<Round head combination screw>
q: SY3000-23-33A
w: SY5000-221-5A Double check
A e: SY7000-221-5A spacer assembly SY3000- SY5000- SY7000-
B with residual 23-33A — 221-5A — 221-5A —
B pressure release (2 pcs.) (2 pcs.) (3 pcs.)
valve
C Individual
SUP (EXH)
C
spacer
assembly
A Valve
<Round head combination screw>
q: SY3000-23-32A
w: SY5000-221-3A
A Individual
e: SY7000-221-3A SUP (EXH)
SY3000- SY5000- SY7000-
B 23-32A — 221-3A — 221-3A —
B spacer
(2 pcs.) (2 pcs.) (3 pcs.)
assembly
C Individual
EXH (SUP)
C
spacer
assembly
298
SY3000/5000/7000 Series
Caution
Tightening torque for mounting screw
M2: 0.16 N·m (SY3000)
Manifold Options: Spacer Combinations and Screw List w M3: 0.8 N·m (SY5000/7000)
q
q SY3000 (M2) w
w SY5000 (M3) e
e SY7000 (M3)
Combination
Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw Round head combination screw Hexagon socket head cap screw
<Round head combination screw> SY3000- SY3000- SY5000- SY5000- SY7000- SY7000-
q: SY3000-23-24A A Valve 23-24A 222-1A 221-1A 222-1A 221-1A 222-1A
w: SY5000-221-1A [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves [for 10 valves
e: SY7000-221-1A (20 pcs.)] (20 pcs.)] (20 pcs.)] (20 pcs.)] (30 pcs.)] (30 pcs.)]
<Hexagon socket head cap screw> SUP stop valve
q: SY3000-222-1A spacer assembly
A
w: SY5000-222-1A B with residual
e: SY7000-222-1A pressure
B
release valve SY30M-56-3A SY50M-56-3A SY70M-56-3A
q: SY30M-56-3A Double check (2 pcs.) (2 pcs.) (3 pcs.)
C w: SY50M-56-3A spacer
e: SY70M-56-3A C assembly with
residual pressure
release valve
Individual
EXH (SUP)
D
spacer
assembly
A Valve
<Round head combination screw>
q: SY3000-23-32A
A w: SY5000-221-7A
e: SY7000-221-7A SY3000- SY5000- SY7000-
Interface
B 23-32A — 221-7A — 221-7A —
B regulator
(2 pcs.) (2 pcs.) (3 pcs.)
C
Individual
SUP (EXH)
C
spacer
assembly
299
Manifold Options SY3000/5000/7000 Series
)
C6: 91.8
N7: 95.6
62.6
)
LN7: 63.3
L6: 60.8
2B B A B A
14 A 14 A
89
(
112.8
4A
(
12 B 12 B
LOCK
PUSH
B A B A B A
92.7
4A 4A
89
101.2
14 A
89
111.6
2B 2B
83.6
12 B
2B
7.2
4A
13.9
One-touch fitting
(SUP port, EXH port)
(100.7)
(111.7)
89
14 A 14 A 14 A 14 A
103.2
(118.3)
B A B A
Applicable tubing O.D.: Ø 4, Ø 5/32" 14 A 14 A
89
101.2
12 B 12 B
1 P
77.6
LOCK
PUSH
2B
(2)
Max. 14
39
05
4A
SY30M- N5 --
06
SY30M- N6 --
SY30M-M1--
77.6
(58.7)
2B
B A B A
14 A 14 A
89
77.6
76.9
4A
62.1
2B
39.9
12 B 12 B
4A
(3.9)
2B
(104.2)
96.6
4A
(72.2)
2B
4A
BA
14 A
B A B A
81.6
14 A 14 A
106.2
BA BA
4A 4A
106.2
116.6
138.6
126.4
142.4
12 B
12 B 12 B
2B 2B
18.2
One-touch fitting
(SUP port, EXH port)
Applicable tubing O.D.: Ø 4, Ø 5/32"
: Ø 6, Ø 1/4"
86.1
(73.6)
: Ø 8, Ø 5/16"
91.6
87.8
74.5
2B
2B
50
4A
4A
1 P
86.1
2B
47
4A
BA BA BA
106.2
B A B A 14 A 14 A 14 A
14 A 14 A
106.2
127.5
127.7
145.5
12 B 12 B 12 B
12 B 12 B
BA BA
14 A 14 A
106.2
LOCK
PUSH
(3)
12 B 12 B
Max. 21
301
Manifold Options SY3000/5000/7000 Series
2B
(119.3)
113.1
4A
(81.4)
2B
4A
B A
14 A
92.1
B A B A B A B A
4A 4A 14 A 14 A
116.7
116.7
116.7
145.1
12 B
164.1
167.1
2B 2B 12 B 12 B
19.2
PUSH LOCK
One-touch fitting
(SUP port, EXH port) <Type 50, 51>
Applicable tubing O.D.: Ø 6, Ø 3/8"
:Ø8
Ø 10
<Type 51, 52>
Individual SUP/EXH spacer SUP stop valve spacer assembly Interface regulator
assembly (Side ported) with residual pressure release valve
One-touch fitting
(SUP port, EXH port)
Applicable tubing O.D.: Ø 6, Ø 1/4"
: Ø 8, Ø 5/16" 101.3
94.3
: Ø 10, Ø 3/8"
81
: Ø 12
99.1
2B
56.5
(85)
2B
4A
4A
1 P
99.1
2B
55
4A
B A B A B A B A B A
14 A 14 A 14 A 14 A 14 A
116.7
116.7
143.8
148.7
161.8
12 B 12 B 12 B 12 B 12 B
B A B A
14 A 14 A
116.7
PUSH LOCK
(2)
(9.6)
12 B 12 B
Max. 21
00
SY70M- N0 -
<Type 50, 51, 52> SY70M-M1-
(For Ø 12)
(21.5)
<Type 50>
302
303
Plug-in Sub-plate Type
[IP67 Compliant]
304
SY3000/5000/7000 Series
Plug-in Single Unit/Sub-plate Type [IP67 Compliant] ®
Metal Seal
Sub-plate Fitting port size 1 J 4/2 4/2 J 5/3
Series
piping location (P, E) (A, B) C b Q [l/min(ANR)]∗2 C b Q [l/min(ANR)]∗2
Side ported 1/8 1/8 1.4 0.14 325 1.3 0.26 322
SY3000 Bottom ported 1/8 1/8 1.3 0.13 300 1.3 0.22 315
Top ported 1/8 C6 1.2 0.22 291 1.4 0.29 354
Side ported 1/4 1/4 3.2 0.13 738 3.5 0.16 820
SY5000 Bottom ported 1/4 1/4 3.0 0.12 688 3.2 0.17 754
Top ported 1/4 C8 2.6 0.23 634 3.2 0.19 762
Side ported 3/8 3/8 4.6 0.10 1044 4.9 0.16 1148
SY7000 Bottom ported 3/8 3/8 4.6 0.10 1044 4.9 0.17 1154
Top ported 3/8 C12 4.0 0.18 947 4.7 0.16 1101
∗ Calculation of effective area S and sonic conductance C: S = 5.0 x C
∗1 The value is for individually operated 2-position type.
∗2 The values have been calculated according to ISO 6358 and indicate the flow rate under standard conditions with an inlet pressure of 0.6 MPa (relative
pressure) and a pressure drop of 0.1 MPa.
305
Plug-in Single Unit/Sub-plate Type [IP67 Compliant]
(Side ported, Bottom ported, Top ported) SY3000/5000/7000 Series
How to Order
In the case of Valve + Sub-plate (Built-in valve type part no.)
Side/Bottom
ported SY 3 1 0 0 5 1 W1 01
Top ported SY 3 1 3 0 5 1 M5 W1 01
q w e r t y u i o !0 !1 !2 !3 !4 !5 !6 !7
q Series o Light/surge voltage suppressor and common specification !2 A, B port thread type (Thread piping)
3 SY3000 Surge voltage Common — Rc
Symbol With light
5 SY5000 suppressor specification F G
7 SY7000 — — — N NPT
R — Non-polar T NPTF
w Type of actuation U ∗ Only — is available for M5.
1 Single S — Positive
2
2-position
Double Z common !3 Type of mounting screw
3 Closed Centre NS — Negative — Round head combination screw
4 3-position Exhaust Centre NZ common B Hexagon socket head cap screw
5 Pressure Centre ∗ For the non-polar type, be careful of surge K Round head combination screw (Drop prevention type)
A∗1 N.C./N.C. voltage intrusion. Refer to page 317 for details. H Hexagon socket head cap screw (Drop prevention type)
4-position ∗ Only “Z” and “NZ” types are available with a
B∗1 dual 3-port
N.O./N.O. ∗ For “K” and “H,” the valve body cover has a
power saving circuit.
C∗1 N.C./N.O. drop prevention construction to stop the
mounting screws from falling out when the
∗1 Only the rubber seal type is available for the
4-position dual 3-port valve.
!0 Manual override valve is removed for maintenance, etc.
—: D: ∗ Refer to page 307 when the base gaskets
e Seal type Non-locking
push type
Push-turn
locking
and mounting screws are required for
maintenance.
0 Rubber seal slotted ∗ When using an optional spacer assembly,
1 Metal seal type “B” and “H” cannot be selected.
∗ When mounting a special order (including Made-to-Order specification) valve or manifold option (spacer, etc.) on the sub-plate, add the valve part
number or spacer part number under the sub-plate part number to place an order. For details, refer to the ordering example on page 307.
∗ When selecting a product with residual pressure release valve or vacuum release valve with restrictor, after selecting a model from page 26 or 28, make
selections for items 15 to 18 above.
306
SY3000/5000/7000 Series
How to Order
In the case of Sub-plate (Sub-plate single unit part no.)
∗ Without valve
SY 3 0M 27 1 W1 01
q w e r t ∗ Base gasket is included.
∗ Valve mounting screws are not included.
q Series e Port location (Sub-plate) t Sub-plate thread type
3 SY3000 — Side ported — Rc
5 SY5000 B Bottom ported F G
7 SY7000 V Top ported [1(P), 5(EA), 3(EB) port: Side ported] N NPT
T NPTF
w Wiring specifications r Port size
WO Without M12 connector cable Symbol Port size Applicable series
W1 With M12 connector cable (300 mm) 01 1/8 SY3000
W2 With M12 connector cable (500 mm) 02 1/4 SY5000
W3 With M12 connector cable (1000 mm) 03 3/8 SY7000
W4 With M12 connector cable (2000 mm)
W7 With M12 connector cable (5000 mm)
∗ Refer to the table below for connector cable
How to Order when mounting a special order (including Made-to-Order specification)
part numbers. valve on the sub-plate (Ordering example: X90)
∗ When ordering a product with M12 connector
cable, the connector cable is included. SY30M-27-1-W1-01 ······ 1 set (Sub-plate single unit part no.)
∗SY3200-5U1-X90·········· 1 set (2-position double part no./Main valve fluororubber specification)
Caution
Due to the properties of the double check spacer, assembly carried out by the customer is not
recommended. If a double check spacer is to be used, be sure to order the type that is built in
to the sub-plate as shown in the ordering example above.
∗ 3 pcs.
q No. Description
Part no.
Note
SY3000 SY5000 SY7000
for the SY7000
Round head SY3000-23-24A SY5000-221-1A SY7000-221-1A Part numbers shown on
Valve combination screw (M2 x 32) (M3 x 32.5) (M3 x 36.5) the left are for 10 valves
q mounting
screw Hexagon socket SY3000-222-1A SY5000-222-1A SY7000-222-1A (20 pcs.).
head cap screw (M2 x 32) (M3 x 32.5) (M3 x 36.5) (30 pcs. for the SY7000)
Base gasket Part numbers shown on the
w (for sub-plate) SY30M-11-1A SY50M-11-1A SY70M-11-1A left are for 10 valves (10 pcs.).
Cable length: 300 mm
ZS-37-L
w Cable weight: Approx. 18 g
Cable length: 500 mm
ZS-37-M Cable weight: Approx. 23 g
M12 waterproof Cable length: 1000 mm
e connector cable ZS-37-N Cable weight: Approx. 36 g
Cable length: 2000 mm
e ZS-37-P Cable weight: Approx. 62 g
Cable length: 5000 mm
ZS-37-C Cable weight: Approx. 140 g
Caution
Tightening torque
M2: 0.16 N·m (SY3000)
M3: 0.8 N·m (SY5000/7000)
307
Plug-in Single Unit/Sub-plate Type [IP67 Compliant]
(Side ported, Bottom ported, Top ported) SY3000/5000/7000 Series
Plug-in Side Ported
Dimensions: SY3000 Series Single Unit/Sub-plate Top Ported
SY30 01 -1-W-01 (Side ported)
1/8
[1(P) port]
20
7.4
Triangle mark Sub-plate side pin arrangement
M5 x 0.8 M5 x 0.8 (No numeric indication)
(PE: External pilot EXH port) (X: External pilot port) COM.
1/8 11 11 9.5
[5(EA), 3(EB) port] 4
3
2
28.6 5.2
SOL.a 1 SOL.b
Manual override 83.2 Unused (Without terminal)
12 B
PE X
(Light/surge voltage suppressor) 5EA 1P 3EB
(42.1)
10.6
52.2 5.8
11.9
67.9 (15.3)
(For 3-position)
14.5 13.3
For "F" marking 1/8
(Thread type) [4(A), 2(B) port] 1: Brown (Unused) 3: Blue (COM.)
12
19
4A 2B
B A
4 A
2B
PE X
(Light/surge voltage suppressor) 5EA 1P 3EB
58.6
(No numeric indication)
28
19.5
20
COM.
(Max. 3)
(Push-turn locking slotted type:
Press, then rotate it. ) 51.1
34.5 8.8 2 x Ø 3.2
4(A) port side: Blue (For rubber seal) (For mounting)
: Grey (For metal seal) 4A 2B
2(B) port side: Yellow
35.9
32.9
B A
(42.1)
14 A
12 B
10.6
PE X
(Light/surge voltage suppressor) 5EA 1P 3EB
(Max. 3)
52.2 5.8
11.9
67.9 (15.3)
(For 3-position)
1: Brown (Unused) 3: Blue (COM.)
2: White (SOL.b) For "F" marking
4: Black (SOL.a) Plug
(Thread type)
19
F
14.7
3.7
8.2
13 13 7.5
5 3 1
3.5
28.3
29.5
4 2
34.5 2 x M3 1/8
2 x Ø 3.4 [1(P), 2(A), 4(B), 5(EA), 3(EB) port] Fitting dimensions for panel mounting
42.5
14.5 13.3 Refer to panel fitting dimensions
for details.
309
Plug-in Single Unit/Sub-plate Type [IP67 Compliant]
(Side ported, Bottom ported, Top ported) SY3000/5000/7000 Series
Plug-in Side Ported
Dimensions: SY5000 Series Single Unit/Sub-plate Top Ported
SY50 01 -1-W-02 (Side ported)
1/4
[1(P) port]
58.6
COM.
28
15.5
13
3
4 2
Triangle mark SOL.a 1 SOL.b
18 18 16
1/4 Unused (Without terminal)
[5(EA), 3(EB) port]
Manual override ( 103.4
Push-turn locking slotted type:
Press, then rotate it. ) 2 x Ø 4.3
(For mounting)
71.3
62 7.4
4(A) port side: Blue (For rubber seal)
: Grey (For metal seal) PE 4A 2B X
2(B) port side: Yellow
32
40
B A
14 A
12 B
(42.1)
10.6
11.9
74.6 3.4
90.3 (16.6)
(For 3-position)
13
17.5
2 B
5EA 1P 3EB
30.5
9.5
(No numeric indication)
5 1 3
4 2
COM.
1/4 18 25
3 [1(P), 2(A), 4(B), 5(EA), 3(EB) port]
4 2
SOL.a 1 SOL.b
58.6
28
15.5
Triangle mark Plug
103.4
(42.1)
(Max. 3)
71.3
(Push-turn locking slotted type:
Press, then rotate it. ) 2 x Ø 4.3
(For mounting)
62 7.4
4(A) port side: Blue (For rubber seal)
: Grey (For metal seal) PE 4A 2B X
(Max. 3)
2(B) port side: Yellow
32
40
B A
14 A
12 B
1: Brown (Unused) 3: Blue (COM.) (Light/surge voltage suppressor) 5EA 1P 3EB
4
2: White (SOL.b) 4: Black (SOL.a)
74.6 3.4
11.9
90.3 (16.6)
Panel fitting dimensions (For 3-position)
2 x M4
2 x Ø 4.5 For "F" marking
(Thread type) 46.4 10.8
M5 x 0.8 M5 x 0.8
4.5
32
40
Plug
(PE: External pilot EXH port) (X: External pilot port)
15.5
17.5
3.5 57
4
F
62
311
Plug-in Single Unit/Sub-plate Type [IP67 Compliant]
(Side ported, Bottom ported, Top ported) SY3000/5000/7000 Series
Plug-in Side Ported
Dimensions: SY7000 Series Single Unit/Sub-plate Top Ported
SY70 01 -1-W-03 (Side ported)
3/8
[1(P) port]
64.3
COM.
30.5
23
16
3
4 2
38
46
B A
14 A
12 B
(42.1)
(Light/surge voltage suppressor)
5 EA 1P 3 EB 15.7
4
4.1
11.9
87.2
102.9 (20.6)
(For 3-position)
PE 4A 2B X
B A
4A
2B
5 EA 1P 3 EB
13
33
Sub-plate side pin arrangement 5 1 4
SOL.a 1 SOL.b
15.7 116.7
Manual override
(Max.3)
84.6
(Push-turn locking slotted type:
Press, then rotate it. ) 2 x Ø 4.3
(For mounting) 73 8.1
4(A) port side: Blue (For rubber seal)
: Grey (For metal seal) PE 4A 2B X
(Max.3)
2(B) port side: Yellow
38
46
B A
14 A
12 B
1: Brown (Unused) 3: Blue (COM.)
5 EA 1P 3 EB
2: White (SOL.b) 4: Black (SOL.a) (Light/surge voltage suppressor)
4
87.2 4.1
11.9
102.9 (20.6)
Panel fitting dimensions (For 3-position)
2 x M4
4.5
2 x Ø 4.5
For “F” marking
(Thread type)
54.8 12.6
46.2
38
M5 x 0.8 M5 x 0.8
(PE: External pilot EXH port) Plug (X: External pilot port)
22
23
69
F
73
313
SY3000/5000/7000 Series
Specific Product Precautions 1
Be sure to read this before handling the products. Refer to the back cover for safety instructions.
For 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products”
and the “Operation Manual” on the SMC website: https://www.smc.eu
Warning Warning
1. Do not use valves in atmospheres of corrosive gases, Push-turn locking lever type [E type]
chemicals, sea water, water, water vapour, or where there is Push down on the manual override by finger until it stops, and
direct contact with any of these. then turn it 60° clockwise. The manual override is then locked.
2. Products compliant with IP67 enclosures (based on IEC60529) To release it, turn it counterclockwise. If it is not turned, it can
are protected against dust and water, however, these products be operated the same way as the non-locking push type.
cannot be used in water. If using in an environment that is
exposed to water and dust splashes, take measures such as
Locked
using a protective cover.
position
3. When using built-in silencer type manifold with an IP67
enclosure, keep the exhaust port of the silencer from coming in
direct contact with water or other liquids.
4. The metal seal valve is provided with a hole to discharge the OFF
pilot EXH. When using in atmospheres containing water and
dust, mount it horizontally. ON
B
Valve Mounting
Carefully check the manual override
Caution projection amount.
(3.7)
Mount it so that there is no Max. (at OFF): 3.7 mm
Series Thread size Tightening torque
slippage or deformation in SY3000 M2 0.16 N·m
gaskets, and tighten with SY5000/7000 M3 0.8 N·m
the tightening torque as
shown to the right.
OFF Locked
position
ON
PUSH
TURN
B A
314
SY3000/5000/7000 Series
Specific Product Precautions 2
Be sure to read this before handling the products. Refer to the back cover for safety instructions.
For 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products”
and the “Operation Manual” on the SMC website: https://www.smc.eu
which is built into a valve (rubber seal type only) and the type manifolds of the side-ported type (Type 5 0 and Type 1 0 ), the
which is built in on the manifold side with a connector bottom-ported type (Type 51 and Type 11), and the top-ported type
connection. Both types have a check valve built in to prevent (Type 5 2 and Type 1 2 ). For example, air output can be obtained
back pressure. from both sides of the A and B ports of the manifold and the valve
Please note that for this reason, even if a valve with an external by mounting a top-ported valve to a side-ported or bottom-ported
pilot specification is used, it cannot be pressurised from exhaust manifold, and a pressure switch can be connected to the output
port [3/5(E)]. As compared with the types which do not integrate port on one side. However, when selecting valves and manifolds,
the back pressure check valve, C value of the flow rate note that when a base-mounted valve is mounted to a top-ported
characteristics goes down. Please contact SMC for details. manifold, there will be no output from the A and B port.
The manifold installed type back pressure check valve
assembly is assembly parts with a check valve structure.
However, since slight air leakage against the back pressure is
allowed due to its structure, adverse effects of the back
pressure due to increase in exhaust resistance cannot be
prevented if the manifold exhaust port and other exhaust ports
are put together for piping or if the piping diameter is narrowed.
As a result, this may cause the actuator and air operated
equipment to malfunction. So, be careful not to restrict the
exhaust air. If the exhaust resistance becomes large, select a
built-in valve type with rubber seal.
Do not switch valves when A or B port is open to the
atmosphere, or while the actuators and air operated equipment
are in operation. For built-in valve type with rubber seal, the
back pressure prevention seal may be peeled off, which may
cause air leakage or malfunctions. Use caution especially when
performing a trial operation or maintenance work.
Exhaust Throttle
Caution
The SY series pilot valve and main valve share a common
exhaust inside the valve. Therefore, do not block the exhaust port
when arranging the piping.
Caution
In case of using a 5-port valve as a 3-port valve
The SY3000/5000/7000 series can be used as normally closed
(N.C.) or normally open (N.O.) 3 -port port valves by closing
one of the cylinder ports 4 (A) or 2 (B) with a plug. However,
they should be used with the exhaust ports kept open. They
are convenient at times when a double solenoid type 3 -port
valve is required.
Single
(EA)5 1 3(EB) (EA)5 1 3(EB)
(P) (P)
Double
(EA)5 1 3(EB) (EA)5 1 3(EB)
(P) (P)
315
SY3000/5000/7000 Series
Specific Product Precautions 3
Be sure to read this before handling the products. Refer to the back cover for safety instructions.
For 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products”
and the “Operation Manual” on the SMC website: https://www.smc.eu
Caution
Polar type With power saving circuit
Positive common Negative common Power consumption is decreased to approx. 1/3 compared with
Single solenoid Single solenoid the standard product by reducing the wattage required to hold
the valve in an energised state. (Effective energising time is
Light/surge voltage suppressor (Z) Light/surge voltage suppressor (NZ) over 67 ms at 24 VDC.)
Polarity protection diode Polarity protection diode ∗ Be careful of the energising time, as quick response and high pressure
COM COM types will become operational when the energising time is over 40 ms.
(+) (−)
LED <Standard> <High pressure>
Coil
Coil
LED
(Red) Electric circuit diagram
[SOL.a] [SOL.a] (Red)
(−) (+) (With power saving circuit) Polarity protection diode
In the case of single solenoid
Surge voltage suppressor (S) Surge voltage suppressor (NS) (+) (+)
Timer circuit
Diode
Diode
PWM circuit
Coil
Coil
Polarity protection diode Polarity protection diode
LED
COM COM
(+) (−)
i2 i1
Coil
Coil
(−)
[SOL.a] [SOL.a] (−)
(−) (+) i1: Inrush current, i2: Holding current
Polarity protection diode
Positive common Negative common Not available for the 12 VDC
specification
Double solenoid, Double solenoid,
3-position, 4-position 3-position, 4-position The circuit shown above reduces the power consumption for
Light/surge voltage suppressor (Z) Light/surge voltage suppressor (NZ) holding in order to save energy. Refer to the electrical power
[SOL.b] [SOL.b] waveform as shown below.
(−) (+) LED
LED <Electrical power waveform with power saving circuit>
Coil
Coil
(Green) (Green)
COM COM
Applied voltage
(+) (−)
LED 24 V
Coil
Coil
LED (Red)
[SOL.a] (Red) [SOL.a]
(−) (+) 0V
Polarity protection diode Polarity protection diode
Coil
Coil
[SOL.a] [SOL.a] 0W
(−) (+) 67 ms (40 ms)
Polarity protection diode Polarity protection diode
The values in ( ) are for the high pressure and quick response types.
Non-polar type • The 12 VDC specification with power saving circuit (standard
With surge voltage suppressor (R) specification) does not have the polarity protection diode. Do
Single solenoid Double solenoid not make a mistake with the polarity.
SOL.b • Since the voltage will drop by approx. 0.5 V due to the
(−,+) transistor, pay attention to the allowable voltage fluctuation.
COM
Coil
(+,−) Varistor (For details, refer to the solenoid specifications of each type
COM of valve.)
Coil
Varistor
(+,−)
SOL.a
Coil
(−,+) Varistor
SOL.a
Residual voltage of the surge voltage suppressor
(−,+) ∗ If a varistor or diode surge voltage suppressor is used, there is
some residual voltage to the protection element and rated
With light/surge voltage suppressor (U)
voltage. Therefore, refer to the table below and pay attention to
Single solenoid Double solenoid the surge voltage protection on the controller side. Also, since
SOL.b LED the response time does change, refer to the valve
(−,+) specifications on page 18.
COM
Coil
(+,−) Varistor
COM Residual Voltage
Coil
Varistor (+,−)
SOL.a Surge voltage DC
Coil
(−,+) Varistor
LED suppressor 24 V 12 V
(Red) SOL.a
(−,+) LED S, Z Approx. 1 V
(Green) R, U Approx. 47 V Approx. 32 V
316
SY3000/5000/7000 Series
Specific Product Precautions 4
Be sure to read this before handling the products. Refer to the back cover for safety instructions.
For 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products”
and the “Operation Manual” on the SMC website: https://www.smc.eu
Relay
Power supply circuit breaker
24 VDC
Output circuit
Surge voltage
24 V
sol.1: Energized
0V
−2 V
R
Surge voltage
Internal circuit
24 V
0V
sol.2: De-energized
−2 V
R
Surge voltage
24 V
0V
Large capacity −2 V
R load: Energized
Countermeasure
Diode parts
– (Anode) + (Cathode)
Relay
Power supply circuit breaker
24 VDC
Type 5 (Metal Base) ,Type 1 (Connector Connecting Base) Changing Connector Entry Direction
Caution
Connector direction for electrical entry of D-sub connector
<IP 4 0 > and flat ribbon cable can be changed. If the directional
change is required, slide the lever on the side of the connector Single wiring
block to the FREE position, and then change the direction as marked with Í
shown in the figure. Also, before connecting the connector, be
sure to return the lever to the LOCK position. (If the lever is
difficult to slide, move the connector a little bit to make it easier to
slide the lever.)
If an excessive force is applied on the connector in the LOCK
position, the connector block may be damaged. Also, using in
such a way that the connector floats in the FREE position, it may
cause the lead wire, etc., to break. Thus, refrain from using in
these ways.
E
FRE
K
LOC
Type 5 Type 1
(Metal base) (Connector connecting base)
318
SY3000/5000/7000 Series
Specific Product Precautions 6
Be sure to read this before handling the products. Refer to the back cover for safety instructions.
For 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products”
and the “Operation Manual” on the SMC website: https://www.smc.eu
Substrate Assemblies inside Manifolds Port Block Assembly and How to Change Piping Types between Top and Side
Caution Caution
Substrate assemblies inside of manifolds cannot be taken apart. For the top-ported type, the port size of A and B ports can be changed
Attempting to do so may damage parts. by switching the port block assemblies which are mounted on the body.
The piping method can also be changed by switching the top-ported
type port block assembly with the side-ported type cover assembly.
Also, it may cause air leakage if the mounting screws are not tightened
Fixation of DIN Rail Mounting Type Manifolds securely enough when they are switched. Take care to tighten to the
correct tightening torque.
Caution Refer to pages 24 and 25 for part numbers of port block assembly and
1. When the manifold is fixed with bolts on a mounting surface, body cover assembly for A, B port and page 225 for part numbers of
etc., it can be operated just by fixing on both ends of the DIN port block assembly and body cover assembly for P, E port.
rail if the bottom surface of the DIN rail is entirely in contact When switching them while valves are mounted on a manifold, remove
with the mounting surface when mounted horizontally. the clip with a flat head screwdriver before switching the port plugs and
However, if it is used with other mounting or with side or the One-touch fittings. It may cause air leakage if the mounting screws
reverse mounting, fix the DIN rail with bolts at regular intervals. are not tightened or the clip is not inserted securely enough when they
As a guide, insert bolts in 2 locations for 2-5 stations, 3 are switched. Take care to tighten to the correct tightening torque.
locations for 6-10 stations, 4 locations for 11-15 stations, 5
locations for 16-20 stations, and 6 locations for 21-24 stations. Caution
2. When using the manifold with DIN rail in an environment where Tightening torque Mounting screw
any vibration or impact is applied to it, the DIN rail itself may be M2: 0.16 N·m (SY3000)
broken. In particular, if the installation surface vibrates when M3: 0.8 N·m (SY5000/7000)
mounting the manifold on the wall or if a load is directly applied Port block assembly
to the manifold, the DIN rail may be broken, causing the Thread piping
Refer to page 24.
manifold to drop. When any vibration, impact, or load is applied
to the manifold, be sure to use the direct mounting manifold. Mounting screw
Plate
Cover assembly
Refer to page 225.
Plug assembly
For SY3000
Removable by screwing an
M3 screw into the centre hole
Plug assembly
Plate Refer to page 226.
319
SY3000/5000/7000 Series
Specific Product Precautions 7
Be sure to read this before handling the products. Refer to the back cover for safety instructions.
For 3/4/5-port solenoid valve precautions, refer to the “Handling Precautions for SMC Products”
and the “Operation Manual” on the SMC website: https://www.smc.eu
Caution Caution
By replacing One-touch fittings of valve or manifold base, it is Bottom ported (Type 11) Plate part nos. (10 pcs. included)
possible to change the connection diameter of the 4(A), 2(B), Secure enough space between A, B port
Series Part no.
1(P), 3/5(E) ports. the manifold blocks when the size
When replacing the One-touch fittings, remove the clip or the plate is detached and attached. SY5000 — SY50M-10-4A
plate and the plate mounting screws with a screwdriver before SY7000 — SY70M-10-4A
pulling the One-touch fittings off. Mount the One-touch fittings by Plate Ø 2, Ø 3, Ø 4
SY3000/5000
following the removal procedure in reverse. Mixed mounting type Ø 6, Ø 1/8" SY50M-10-5A
It may cause air leakage if the mounting screws are not tightened (For mounting Ø 5/32", Ø 1/4"
or the clip and the clip plate are not inserted securely enough the SY3000)∗1 Ø 8, Ø 5/16" SY50M-10-4A
when they are switched. Take care to tighten to the correct ∗1 The part number for mounting the
tightening torque. Refer to page 226 for part numbers of SY5000 is SY50M-10-4A.
One-touch fittings for valve or manifold. ∗ The part number for the SY5000/7000
Manifold block mixed mounting type is SY70M-10-4A.
Valve
One-touch fitting
Other Tube Brands
Caution
1. When using other than SMC brand tube, confirm
Port plate that the following specifications are satisfied with
Caution respect to the tube outside diameter tolerance.
Tightening torque 1) Nylon tube within ±0.1 mm
2) Soft nylon tube within ±0.1 mm
M2: 0.16 N·m
(SY3000) 3) Polyurethane tube within +0.15 mm
M3: 0.8 N·m –0.2 mm
(SY5000/7000) Do not use tube which do not meet these outside diameter
Plug-in metal base tolerances. It may not be possible to connect them, or they
may cause other trouble, such as air leakage or the tube
Side ported (Type 50) Bottom ported (Type 51) pulling out after connection.
Clip
One-touch Fittings
Caution
When fittings are used, they may interfere with one another depending on their types and sizes. Therefore, the dimensions of the fittings
to be used should first be confirmed in their respective catalogues.
Fittings whose compliance with the SY series is already confirmed are stated below. If the fitting within the applicable range is selected,
there will not be any interference.
321
These safety instructions are intended to prevent hazardous situations and/or equipment
Safety Instructions damage. These instructions indicate the level of potential hazard with the labels of
“Caution,” “Warning” or “Danger.” They are all important notes for safety and must be
followed in addition to International Standards (ISO/IEC) 1), and other safety regulations.
1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Caution indicates a hazard with a low level of risk
ISO 4413: Hydraulic fluid power – General rules relating to systems.
Caution: which, if not avoided, could result in minor or moderate IEC 60204-1: Safety of machinery – Electrical equipment of machines.
injury. (Part 1: General requirements)
Warning indicates a hazard with a medium level of risk ISO 10218-1: Manipulating industrial robots - Safety.
etc.
Warning: which, if not avoided, could result in death or serious
injury.
Danger indicates a hazard with a high level of risk
Danger: which, if not avoided, will result in death or serious
injury.
Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.
SMC Corporation (Europe)
Austria +43 (0)2262622800 www.smc.at office@smc.at Lithuania +370 5 2308118 www.smclt.lt info@smclt.lt
Belgium +32 (0)33551464 www.smc.be info@smc.be Netherlands +31 (0)205318888 www.smc.nl info@smc.nl
Bulgaria +359 (0)2807670 www.smc.bg office@smc.bg Norway +47 67129020 www.smc-norge.no post@smc-norge.no
Croatia +385 (0)13707288 www.smc.hr office@smc.hr Poland +48 222119600 www.smc.pl office@smc.pl
Czech Republic +420 541424611 www.smc.cz office@smc.cz Portugal +351 214724500 www.smc.eu apoioclientept@smc.smces.es
Denmark +45 70252900 www.smcdk.com smc@smcdk.com Romania +40 213205111 www.smcromania.ro smcromania@smcromania.ro
Estonia +372 6510370 www.smcpneumatics.ee smc@info@smcee.ee Russia +7 8127185445 www.smc-pneumatik.ru info@smc-pneumatik.ru
Finland +358 207513513 www.smc.fi smcfi@smc.fi Slovakia +421 (0)413213212 www.smc.sk office@smc.sk
France +33 (0)164761000 www.smc-france.fr info@smc-france.fr Slovenia +386 (0)73885412 www.smc.si office@smc.si
Germany +49 (0)61034020 www.smc.de info@smc.de Spain +34 945184100 www.smc.eu post@smc.smces.es
Greece +30 210 2717265 www.smchellas.gr sales@smchellas.gr Sweden +46 (0)86031240 www.smc.nu smc@smc.nu
Hungary +36 23513000 www.smc.hu office@smc.hu Switzerland +41 (0)523963131 www.smc.ch info@smc.ch
Ireland +353 (0)14039000 www.smcautomation.ie sales@smcautomation.ie Turkey +90 212 489 0 440 www.smcpnomatik.com.tr info@smcpnomatik.com.tr
Italy +39 03990691 www.smcitalia.it mailbox@smcitalia.it UK +44 (0)845 121 5122 www.smc.uk sales@smc.uk
Latvia +371 67817700 www.smc.lv info@smc.lv
Printing ZS 00 Printed in Spain Specifications are subject to change without prior notice and any obligation on the part of the manufacturer