CAST AKG P SARA CASTCO TESTING CENTRE LTD. Test Certified Drift Expanding Test of Copper and Copper Alloys (Seamless) Round Copper Tubes for Water, Gas in Sanitary, and Heating Applications (BSEN 1057 :2006+AL : 2010 Clause .7) (Fest method : Clause 10.7) Date of issue: 17 June 2013 Page 1B_of 1 page Casteo LRN: DP0121 109.060 DE Details as supplied by customer Customer: Shun Lee Bldg. Materials & Sanitary Wares Ltd. Customer's ref, n0.; = Contract no.: Job title: Description of tube: Nominal outside diameter: 22 mm Copper Pipe (Hot Water) Nominal thickness: 0.9 mm Brand name: DECO ‘Material temper; R250 Body marking: DECO SUPREME COPPER TUBE BS EN10S7 TYPE X L1-L/ff 22 x 0.9 20081V Delivery date: — Type: Hot Water Laboratory Test Result Date sample received: 09 November 2012 Date of test: 11 December 2012 Ambient temperature: 21 °C Specimen no, P0121 109-060 Length (am)} 33 Original outside diameter (D1) (am)} 2 Final vibe outside diameter (D2)= DI x 1.3 (am) 29 Test result Passed Remarks : 1, The driftexpanding test was carried out by using a 45° mandrel 2. Test reals relate only to the specimen tested 3, Test result ofthe sample comply with the requirement of BSEN 1057 : 2006 Clause 7.7+A1 : 2010 & Clause 10. 4, This test report supersedes previous test report of Castco LRN : DPO121109-060A DE issued on 16 May 2013, Checked by : Certified by : TU HO MAN Ass eae Oe por cae erie CHOT TEE WING a PRD ai tO eae BAD ARBEIT 00. On Kui Stool, Faning, Hong Kong, Tel: 2677 2188 $380) MRA 2VAR 20K, On Chuen Stroot, Fang, Hong Kong. Fax: 2677 0361 Emel cestoo@netvgetozcom Webs: www.castoa.com.hk ae) £m BRR SARAA CASTCO TESTING CENTRE LTD. Test Certified Hydrostatic Test on Copper and Copper Alloys (Seamless) Round Copper Tubes for Water, Gas in Sanitary, and Heating Applications (BSEN 1057 : 2006+A1 : 2010 Clause 7.4) (lest method : Clause 10.9 Method C2) Date of issue: 17 June 2013 Page 1B of I page Casteo LRN: DPO121109-060 HYD ‘Details as supplied by customer ‘Customer: Shun Lee Bldg, Materials & Sanitary Wares Ltd, Customer's ref, no.: ~ Contract no.: -- Job title: ~ Description of tube ‘Nominal outside diameter: 22. mm Copper Pipe (Hot Water) Nominal thielmess: 0.9 mm Brand name; DECO Material temper: R250 Body marking: DECO SUPREME COPPER TUBE BS EN10S7 TYPE X L-L-Ufft 22 x 0.9 20081V Dalivery date: — Type: Hot Water Taborators Test Resul Date received: 09 November 2012 Date of test: 12 December 2012 |Specimen no, ‘DPO121109-060 Hydrostatic pressure apply (bar) 3s Sustain period ee) 10 lObservation No leakage was observed |Test result Passed Remarks : 1, ‘Test results relate only to the specimen tested 2, Test results of the sample comply with the requirement of BSEN 1057 : 2006+Al : 2010 Clause 7.4 & Clause 10.9 Method C2. 3, This test report supersedes previous test report of Castco LRN : DPO121109-060A HYD. issued on 16 May 2013 Checked by: Gi: Certified by FU HO MAN ‘MivottehetOnse End of Report BYALA GIB 33, On Kul Stoot, Fanling, Hong Kong. Tel: 2677 2198, $MM AGAR 0A, On Chuen Steet, Fanling, Hong Kong. Fax: 2677 0951 smal: castco@netuigato.com Website: wevw.casico.com.hk ARKH PO ARAA CAST CASTCO TESTING CENTRE LTD. Test Certified Dimensions and Tolerances on Copper and Copper Alloys (Seamless) Round Copper Tubes for Water, Gas in Sanitary, and Heating Applications (BSEN 1087 : 2006+A1 : 2010 Clause 7.3) Date of issue : 17 June 2013 Page 1B of 1 page Castco LRN: DP0121109-060 DIM Details as supplied mer Customer: Shun Lee Bldg. Materials & Sanitary Wares Ltd Customer’ ref. no.: = Contract no.: = Job title: ~ Description of tube: Nominal outside diameter: 22 min Copper Pipe (Hot Water) ‘Nominal thickness: 0.9 mm Brand name: DECO Material temper: R250 Body marking: DECO SUPREME COPPER TUBE BS EN10S7 TYPE X H1-Vt{t 22 x 0.9 20081V Delivery date: —- ‘Type: Hot Water Laboratory Test Result Date sample received: 09 November 2012 Date of test: 11 December 2012 Specimen no,; DPD121 109-060 Measured value (mn) Result Mean Outside diameter 22.02 Passed ‘Thickness 0.92 Passed Lengtis 2505 Passed Remarks: 1, Test results relate only to the specimen tested. 2, Test results of the sample comply with the requirement of BSEN 1057 : 2006+A1 : 2010 Clause 7.3. 3, This test report supersedes previous test report of Casteo LRN : DP0121 109-860 DIM issued on 16 May 2013, Chekety tH cot FU HO MAN CHOTTZE WING Aint Tste Oe End of Report Ca, MRI MICE _ ‘Quality Manager RB HR AKIRR 93, On Kul Street, Fanling, Hong Kong. Tel: 2677 2198 GMMR ALTIVA OA, On Chun Street, Faning, HongKong, Fax: 2677 0851 E-mail: casteo@nelvigatorcom Website: wonw-castco.com.hk ENEARPOARDA Eas CASTCO TESTING CENTRE LTD. Test Certified Surface Quality by Carbon Film Test (BSEN 1057 : 2006+A1 : 2010 Clause 7.5) [Test method : Clause 10.5 (Annex BY] Date of issue + 17 June 2013 Page 1B_of 1 page Casteo LRN: DP0121109-060 CR ‘Details as supplied by customer Customer: Shun Lee Bldg, Materials & Sanitary Wares Lid Customers ref. no. — Contract no: Job ttle: ~ Description of tube Nominal outside diameter: 22 mm Copper Pipe (Hot Water) Nominal thickness: 0.9 mm Brand name: DECO Material temper: R250 Body marking: DECO SUPREME COPPER TUBE BS ENIOS7 TYPE X I--Vif 22.x 0.9 20081V Delivery date: = ‘Type: Hot Water Laboratory Test Result Date sample received: 09 November 2012 Date of test: 14 December 2012 Specimen no. Specimen size ‘Test result P0121 109-060 Length: 25 mm Passed Remarks : 1, Test results relate only to the specimen tested. Passed!" refers to "No detection of carbon" and "failed" refers to "detection of carbon’ Test results of the semple comply with the requirement of BSEN 1057 ; 2006 Clause 7.5+A1 : 2010 & Clause 10.5 (Annex B). This test report supersedes previous test report of Casteo LRN : DP0121109-060A CF issued on 16 May 2013, Checked by : & Centified by FU HO MAN Endof Report emt S07 30,-téenvane” ASSN Tcl Oe oe ey Meer BBA ME BHF 33H 93, On Kul Soot, Faning, Hong Kong. Tol: 2677 2138 BRN Y RAMA 298, On Chuen Street, Fanling, Hong Kong. Fax: 2677 0351 E-mail: castoo@notvigatorcom Website: www.castoo.com.hk CAST EABARPOARAA CASTCO TESTING CENTRE LTD. H58A HARA 99, On Kul Stews, Faning, Hong Kong. Tal: 26772198, #1 4}-HE24i2IA M200, On Chuen Steet, Fanling, Hong Kong. Fax: 2877 0361 Ermal:castzo@nsvigatorcom Webste: wi.castes com. Teer ‘est Report Vickers Hardness Test on Metallic Materials (BS EN ISO 6507 : Part 1: 1998) Date of issue : 16 May 2013 Page 1A of 2 pages Casteo LRN: DP0121109-060 VH. Detatts as supplied by eltent: Client : Shun Lee Bldg, Materials & Sanitary Wares Ltd, Client's ref. no.» = ‘Address ; 15/P, Grandion Plaza, 932 Cheung Sha Wan Road, Lai Chi Kok, Kowloon Contract no. + = Job title : — ‘Test location ‘site : Castco Testing Centre Lid Acceptance standard : BS EN10S7 : 2006 + Al : 2010 Test piece no: DPO121109-060 Test result Date received : 09 November 2012 Date of test : 20 December 2012 Parent metal : Copper Pipe DN22, Temper R250 (Hot Water) Thickness of material: 0.9 mm [Sketch of Test locations ‘Testing Technique? Requirement 1. Rage of Hardess nv i-11v30 2. Time alain the specified force 8 3. Holdtime Ms~ 15s 4. Ambiente. 2345 5. Test pice thickness suse 6 Test loc surfaces, Top and bottom Ccean, smoot 7. Rigid support surace (loan, smo 8 Diting esting no displacement trig support, no shock or vibration 8, Bdgeclearance 22sd 10, Cente to contr earsnoe 23d 1, Correction fates or curved satis ‘Teble B86 ote MOOT) VE MART dea "BIAS has screeds buat Oe. No 32-THST) dae HOKILAS ir pei aboaoryaaiiea ised nthe HOXKAS dec oftredeabesoe_ Throne reps us wt pon men apnovl ea is bara Tae abrtary aad fo sera ih the recgnved Inematnal Sunaed SOTEC 17S. Tas ere demons compete fatto op ends open falsbotary ea runagetmty tem reo 50 LAC IAF Cenc ASTCO EABRKRPOCARA A CASTCO TESTING CENTRE LTD. %& BH RE BIW 33, On Kul Street, Fanling, Hong Kong. Tel : 2677 2138 BNA SAGA 29h, On Chuen Stoo, Fas Kong, Fax: 2677 0061 Erma castcodinetvigaorcom, Webeto: wwn.casco com beat Report ing ‘Vickers Hardness Test on Metallic Materials (BS EN ISO 6507 : Part 1 : 1998) Date of issue: 17 June 2013, Page 2B of 2 pages Casteo LRN | DPO121109-060 VH Test results: Test | “al | "42 | Mean [Mittecence] “Hardness | Test | “at | "a2 | Mean |*Ditteencd] ** Hardness locations | (mm) | (mm) | (mm) | _ (6) _| reading (2V) I locations |_ (mm) | (mm | mm |_@)_| reading (HY) 1 [0338 | 0.339 [0339 [03 807 ‘i= diagonal of the indentation Readings high lighted, If dl & €2 difference for more than 5% * Round off to nearest 10 HV Remark: 1. Test results relate only tothe specimen teste. 2. Compliance ofthe test results to the specification is an opinion of te laboratory ancl is not covered under the HOKLAS accreditation 3.Body marking: DECO SUPREME COPPER TUBE BS ENI057 TYPE X ELV/if 22 x 0.9 20081V 4. This test report supersedes previous test report of Casteo LRN : DP0121109-060A Vi t FU HO MAN ‘Checked by: eer Approved Signatory: HRAShasaoete hsaboatoy (Rep Ne. 032-TEST ade HOKLAS pA HU SAU esas sedis ie HOKLAS deer farce abrases. Tsapara tbe poo es eke! i abot. This intr ace acdc Wi ie ecgase cto Sane ISOTEC 17S, Ths ‘Eseddos sss col umpc rade scp tbe operant barny alt oanageien en eter S0.1-AC LAP Conan dd oy 300) oa eA RRR POARA A CASTCO TESTING CENTRE LTD. Test Certificate Metallic Materials Tensile Test (BS EN 1002-1 : 2001) Date of issue: 17 June 2013 Page IB of 1 page(s) ‘Casto LRN : DP0121109-060 TEN Details es supe Customer: Shun Lee Bldg, Materials & Sanitary Wares Ltd Customer's Ret. No. : = ‘Adess: 1SIF, Grandion Plaz, 932 Chevng Sha Wen Road, Lai Chi Kok, Kowloon Contract No. : = Job Title: = Origin of copper : ~ Grade de Foam of copper product : ~ No. & Type of specimen suppliod: 1 no, 22mm Copper Pipe Hot Water) Acceptance standard: BS ENIOS7 2006+ AL :2010 Body merking: DECO SUPREME COPPER TUBE BS EN10S? TYPE X Supplier: Location ia works: = Nominal diameter: 0.922 mm Band ame: DECO tt 2230.9 200810 Laboratory Test Result Date Received : 09 November 2012 Date Tested : 13 December 2012 Tensile Test Type | Width or ‘Org, Neeet] Ore Gauge) Yield | Tonle Pos Specimen | Grade | & | Diameter | Thickness | Arca | Length | Strength | Stengt | Elongation of | Remark eatity Preparo | (mm) | _ (mm), (mm) | cura) | cura) |_(%) _| Fracture pPa121109 : “N60 | R250] AN | 2203 | 093 616 4s 7 264 36 | valia | Remarks 1. Legends: A~Proportional; B =Non - proportional; M-Machined N- Unmechined + This measurement fs invalid! which relates to the postion of facture only 2, Tost results relate only tothe spesimen tested. 3, Test results comply with BS BNIOS7 : 2006 + AI :2010, 4. This tes report supersedes previous tes report of Casteo LRN : DPO12L q_ FU HO MAN ected ty: Es er [Bod of Report GHOT 109-060A TEN issued on 16 May 2013. Centied by ‘Cas, MIKIE, MICE ‘Grey Managar $ BR BT HEG}33 HR 95, On Kul Street, Fanling, Hong Kong. Tel: 2677 2138 # BNR KZIHIAB, 20K, On Chuon Soot, Fanling, Hong Kong. Fax: 2677 0951 E-mail: castco@ netvigator.com Website: wnvcastco.com.hk eAGRRPSARAA CASTCO CASTCO TESTING CENTRE LTD. Test Certified Flanging Test of Copper and Copper Alloys (Seamless) Round Copper Tubes for Water, Gas in Sanitary, and Heating Applications (BSEN 1087 : 2006+A1 : 2010 Clause 7.8) Date of issue: 17 June 2013, Page 1B of 1 page Casteo LRN: DPO121 109-060 FT Details as supplied by customer | Customer: Shun Lee Blég, Materials & Sanitary Wares Ld. Customers ref, no.: = Contract no.: == Job title: -= Deseription of tube: Nominal outside diameter: 22 mm Copper Pipe (Hot Water) Nominal thickness: 0.9 mm Brand name: DECO ‘Material temper: R250 Body marking: DECO SUPREMR COPPER TUBE BS EN1057 TYPE X Il-Dift 22 x 0.9 20081V Delivery date: == ‘Type: Hot Water Laboratory Test Result Date sample received: 09 November 2012 Date of test: 11 December 2012 Ambient temperature: 21°C Specimen no. DPO121109-060 Lent (um)] 3B loriginal outside diameter (om) 22 Final tude outside diameter om] 2» Visible cracks without using magnifying aids No Test result HE Passed on Remarks: 1. The flanging test was carried out on a flanging tool with « comer radius of approx. Imm, 2, Test rests relate only to the specimen tested | 3. Test results ofthe sample comply with the requirement of BSEN 1057 : 2006+AJ : 2010 Clause 7. & Clause 10.8 4, This test report supersedes previous test report of Castco LRN : DPO121109-060A FT issued on 16 May 2013 etalay “z catty | 4% BME HG IIW 9G, On Kul Srost, Faning, Hong Kong. Tel: 2677 2198, HER WAVPI2VA W208, On Chuon Street, Fanling, Hong Kong. Fax: 2677 0351 ‘E-mail: castoo@netvigatorcom Website: wwrw.castco.com.hk

You might also like