You are on page 1of 3

Table 3.

1: Details of Trial Mixes

Fine Coarse Mix proportions by


Cement Water
Mix Id Aggregate Aggregate Weight
(kg/m3)
Trial Mix-1 200 715 1075 120 1:3.57:5.37@ 0.60 W/C
Trial Mix-1 230 715 1075 143 1:3.11:4.67@ 0.62W/C

A total of three cylinders were cast for each trial mix, which were tested at the age of 07 and
28 days the average compressive strength test results along with the slump test results of each
trial mix are presented in Table 3.2

Table 3.2: Workability and Compressive strength Test Results of Trial Mixes

Mix proportions by Slump Average Compressive Strength ,psi


Mix Id
Weight (mm)
At 7 Days At 28 Days
Trial Mix-1 1:3.57:5.37@ 0.60 W/C 10 1289 1901
Trial Mix-1 1:3.11:4.67@ 0.62W/C 15 1537 2187

4. RECOMMENDED MIX PROPORTIONS:

Table 3.2 indicates that for the given specifications and design input data, Trial Mix-2 is most
satisfactory from the workability and strength point of view. Hence, the proportions of Trial
Mix-2 are recommended. The recommended mix proportions are as follows

Cement Content : 230 kg/m3


Fine Aggregate Content : 715 kg/m3
Coarse Aggregate Content : 1075 kg/m3
Water Content : 143 kg/m3
Water/Cement Ratio : 0.62
Mix Proportion by Weight : 1 : 3.11 : 4.67

 Calculation of Volumetric Batching:

Cement Content : 230/1246 = 0.184m3


Fine Aggregate Content : 715 1793 = 0.399 m3
Coarse Aggregate Content : 1075/1418 = 0.758 m3
Water Content : 143/1000 = 0.143 m3 (143 liters)
Mix Proportion by Volume : 1:2.17:4.12

4|Page
Table 3.1: Details of Trial Mixes

Fine Coarse Admixture Mix proportions by


Cement Water
Mix Id Aggregate Aggregate ml/kg Weight
(kg/m3)
Trial Mix-1 325 610 1120 173 4 1:1.87:3.45@ 0.53 W/C
Trial Mix-1 350 610 1120 173 5 1:1.74:3.2@ 0.55W/C

A total of three cylinders were cast for each trial mix, which were tested at the age of 07 and
28 days the average compressive strength test results along with the slump test results of each
trial mix are presented in Table 3.2

Table 3.2: Workability and Compressive strength Test Results of Trial Mixes

Mix proportions by Slump Average Compressive Strength ,psi


Mix Id
Weight (mm)
At 7 Days At 28 Days
Trial Mix-1 1:1.87:3.45@ 0.53 W/C 95 2041 2928
Trial Mix-1 1:1.74:3.2@ 0.55W/C 130 2274 3189

4. RECOMMENDED MIX PROPORTIONS:

Table 3.2 indicates that for the given specifications and design input data, Trial Mix-2 is most
satisfactory from the workability and strength point of view. Hence, the proportions of Trial
Mix-2 are recommended. The recommended mix proportions are as follows

Cement Content : 350 kg/m3


Fine Aggregate Content : 610 kg/m3
Coarse Aggregate Content : 1120 kg/m3
Water Content : 194 kg/m3
Admixture Ultra SP-470 : 5 ml/kg cement
Water/Cement Ratio : 0.55
Mix Proportion by Weight : 1 : 1.74 : 3.20

 Calculation of Volumetric Batching:

Cement Content : 350/1246 = 0.281m3


Fine Aggregate Content : 610 1793 = 0.340 m3
Coarse Aggregate Content : 1120/1418 = 0.790 m3
Water Content : 194/1000 = 0.194 m3 (194 liters)
Mix Proportion by Volume : 1:1.21:2.81

4|Page
Table 3.1: Details of Trial Mixes

Fine Coarse Admixture Mix proportions by


Cement Water
Mix Id Aggregate Aggregate ml/kg Weight
(kg/m3)
Trial Mix-1 430 635 1075 212 5 1:1.48:2.50@ 0.49 W/C
Trial Mix-1 460 635 1075 232 6 1:1.38:2.34@ 0.50W/C

A total of three cylinders were cast for each trial mix, which were tested at the age of 07 and
28 days the average compressive strength test results along with the slump test results of each
trial mix are presented in Table 3.2

Table 3.2: Workability and Compressive strength Test Results of Trial Mixes

Mix proportions by Slump Average Compressive Strength ,psi


Mix Id
Weight (mm)
At 7 Days At 28 Days
Trial Mix-1 1:1.48:2.50@ 0.49 W/C 115 2773 3832
Trial Mix-1 1:1.38:2.34@ 0.50W/C 145 3061 4092

4. RECOMMENDED MIX PROPORTIONS:

Table 3.2 indicates that for the given specifications and design input data, Trial Mix-2 is most
satisfactory from the workability and strength point of view. Hence, the proportions of Trial
Mix-2 are recommended. The recommended mix proportions are as follows

Cement Content : 460 kg/m3


Fine Aggregate Content : 635 kg/m3
Coarse Aggregate Content : 1075 kg/m3
Water Content : 232 kg/m3
Admixture Ultra SP-470 : 6ml/kg cement
Water/Cement Ratio : 0.50
Mix Proportion by Weight : 1 : 1.38 : 2.34

 Calculation of Volumetric Batching:

Cement Content : 460/1246 = 0.369m3


Fine Aggregate Content : 635 1793 = 0.354 m3
Coarse Aggregate Content : 1075/1418 = 0.758 m3
Water Content : 232/1000 = 0.232 m3 (232 liters)
Mix Proportion by Volume : 1:0.96:2.05

4|Page