User's Instruction – TWIN-3 System

Automatic Twin-3 Lubrication System with Twin-3 display


The system consists of: Testing the Twin system:
A lubrication pump with integrated control unit.
Performing a single lubrication cycle:
Distribution blocks with metering units.
A display that indicates failures, low level or Switch ignition ON.
push-button for choosing interval time modes. Push the switch-button for at least 5-seconds at display.
Accordingly, the 3-digit display starts flashing.
System performance: Push the switch-button repeatedly until code “T1” shows.
The system performs all operations automatically. After the Leave the code “T1” flashing until code comes on.
ignition is switched-ON the pump will at pre-set intervals The system will operate a single greasing cycle.
supply measured quantities of lubricant to all grease points. During operation the green LED at Twin-3 display
After system is powered up the Twin-3 display indicates the will flash slowly (2-sec. on / 2-sec. off).
active duty mode (Green LED ). Or push the test-button at pump unit for 2-4 seconds in
order to perform a single cycle.
Twin-3 display:
With the switch-button a desired operating/test mode can be In order to provide additional grease to all grease points
selected or errors can be reset. The Twin-3 display is (i.e. after cleaning the machine) or to bleed the system, a
equipped with a 3-digit display. Herewith errors, the active continuous lubrication cycle can be performed.
duty and test mode can be displayed. The decimal DOT
indicates whether the interval timer remains or is on standby. Performing a multiple lubrication cycle:
The green LED indicates that the system is activated. Switch ignition ON;
The yellow LED indicates when the minimum grease level Push the switch-button at least for 5 seconds at display.
has been reached. The red LED indicates a malfunction. Accordingly, the 3-digit display starts flashing;
Push the switch-button repeatedly until code “T2” shows;
Changing the duty mode:
Leave the code “T2” flashing until code comes on.
The system will operate a multiple greasing cycle.
+ + + During operation the green LED at Twin-3 display
Light duty cycle Medium duty cycle Heavy duty cycle will flash quickly (0.2-sec. on / 0.2-sec. off).
(long interval times) (medium interval times) (short interval times) Or push the test-button at pump unit for 6-10 seconds in
order to perform a multiple cycle.
Push the switch-button at least for 5-seconds. Accordingly, Switch OFF the ignition to finish the multiple greasing cycle.
the 3-digit display starts flashing; Push the switch-button
Grease recommendations:
repeatedly until the desires mode shows. Leave desired duty
mode flashing for at least 6-seconds until the duty mode Molybdenum (MoS2 / 5%) is allowed in the system.
comes on confirming the desired duty mode has changed. For restrictions please contact your Groeneveld dealer.
Use of the correct grease in the TWIN-3 system is of
Filling the reservoir: utmost importance (see table below).
If the yellow LED is lit, the minimum level of the reservoir has
been reached. The reservoir has to be refilled as soon as Do NOT use grease with the following additives:
possible. - Teflon (PTFE), Graphite and Copper base.
Remove the dust cap from the filler coupling.
Carefully clean filler coupling & coupling on the filler hose. Table of prescribed lubricants:
Connect the filler hose to the filler coupling at pump. Min. operating Max. operating
The maximum pressure to fill the reservoir is; 800 PSI, temperature of temperature of Use NLGI class
to avoid damaging of the filter. Fill the reservoir up to
the system the system
the maximum level, which is indicated on the reservoir.
Remove the filler hose and fit the dust cap on filler coupling. -25°C / -13°F 80°C / +176°F 2
< -25°C / -13°F 0°C / +32°F 0/1
Note:
< -25°C / -13°F 80°C / +176°F Synthetic 2
- The filler coupling / filter need to be cleaned every 500
< -25°C / -13°F 0°C / +32°F Synthetic 0 / 1
hours or when excessive resistance is felt when refilling.

TWIN Malfunction reports of the TWIN-3 System with Twin-3 display


General malfunction Cause Solution
1. All grease points appears to a.) The preset greasing interval is too long for the a.) Select the “Heavy duty mode” with switch-button and or shorten
receive insufficient grease and application. the interval period times with Uni- or PC-Gina.
no malfunction report is shown b.) The interval clock does not run (wiring). b.) Check the interval clock command wiring & connection (green
at the Twin-3 display. wire no.3 / pump connector pin no.3).
c.) The interval clock does not run (parameter). c.) Check whether the “timer activation options” are set
correctly, with the use of Uni- or PC-Gina.
2. All grease points appears to be The preset greasing interval is too short for Select the “Light duty mode” with the switch-button and or increase
over greased. the application. the interval period times with Uni- or PC-Gina.
3. 1 or more grease points appears to a.) Crushed / damaged secondary lines. a.) Check and repair / replace secondary line.
be dry while other points receive b.) Metering unit with lesser output selected. b.) Install a metering unit with more output.
sufficient grease. c.) Metering unit defective. c.) Replace metering unit.
d.) 1 or more grease points receive a.) Metering unit with too much output selected. a.) Install a metering unit with less grease output.
excessive amount of grease while b.) Metering unit with internal leak. b.) Replace metering unit.
other points receive sufficient
grease.

Website: www.groeneveld-group.com
Error code / Malfunction Cause Solution
1. One or all LED’s and/or 3-digit display a.) No supply voltage at the display. a.) Check fuses and/or wire connection (yellow wire). Repair when necessary.
does not light up partially b.) Ground wire disconnected. b.) Check the ground wire (brown wire). Repair when necessary.
or completely the moment the c.) Display does not perform a self test, but a single LED or c.) Replace Twin-3 display.
3-digit display is defective.
ignition is switched on. d.) Defective display. d.) Replace Twin-3 display.
a.) The green command wire no. 3 is stopping the interval a.) Check whether wire no. 3 for stopping the timer is connected correctly.
2. Decimal DOT is lit constantly timer. See wiring diagram figure 2.4 of General manual EF1703, if available.
(interval timer stop), while it b.) The green command wire no. 3 is stopping the interval b.) Check with the use of an Uni-Gina or PC-Gina whether the timer activation
suppose to run (interval timer run). timer. options are set correctly. Change when necessary.
The pressure switch did not close during a greasing cycle in a.) Check condition of primary lines and its connectors. Replace or repair
3. + = Successive no primary line-A. Possibly caused by; when necessary.
pressure in line-A a.) Broken / damaged primary line-A. b.) Proceed with “Procedure when an internal system leak is suspected” on
page 43 of General manual EF1703.
b.) Metering unit causes internal bypass. c.) 1: Refill grease reservoir until air pockets have left reservoir.
See section “Filling the reservoir” in this User Guide.
c.) Air trapped into pump unit and or primary line-A. 2: Bleed the pump and primary line-A. Proceed with paragraph 4.3
& 4.4 “Bleeding pump & system” in General manual EF1703.
The pressure switch did not close during a greasing cycle in a.) Check condition of primary lines and its connectors. Replace or repair
4. + = Successive no primary line-B. Possibly caused by; when necessary.
pressure in line-B b.) Proceed with “Procedure when an internal system leak is suspected” on
a.) Broken / damaged primary line-B. page 43 of General manual EF1703.
c.) 1: Refill grease reservoir until air pockets have left reservoir.
b.) Metering unit causes internal bypass. See section “Filling the reservoir” in this User Guide.
2: Bleed the pump and primary line-B. Proceed with paragraph 4.3
c.) Air trapped into pump unit and or primary line-B. & 4.4 “Bleeding pump & system” in General manual EF1703.
The pressure switch was still closed at the outset of a cycle in
5. + = Successive pressure primary line-A. Possibly caused by;
before cycle in line-A a.) Damaged PS wiring harness to where wires are joined. a.) Check wiring and connectors. Replace or repair when necessary.
b.) 5/2-way valve in pump unit did not operate correctly. b.) Check 5/2-way valve and operate manually with the use of an Uni-Gina or
PC-Gina. Replace when necessary.
c.) Pressure switch failed / defective. c.) Check and or replace pressure switch.
The pressure switch was still closed at the outset of a cycle in
6. + = Successive pressure primary line-B. Possibly caused by;
before cycle in line-B a.) Damaged PS wiring harness to where wires are joined. a.) Check wiring and connectors. Replace or repair when necessary.
b.) 5/2-way valve in pump unit did not operate correctly. b.) Check 5/2-way valve and operate manually with the use of an Uni-Gina or
PC-Gina. Replace when necessary.
c.) Pressure switch failed / defective. c.) Check and or replace pressure switch.
Cycles that have not been performed due to grease reservoir
7. + = Empty grease reservoir ran empty and disabled pump, caused by;
a.) Max. number of cycles with an activated low level switch a.) Refill the reservoir. Proceed with section “Filling the reservoir” in this User
exceeded (with “pump low level stop” activation). Guide.
b.) A combination of an activated low-level switch and initial b.) Refill the reservoir. Proceed with section “Filling the reservoir” in this User
“No pressure line-A or -B” error, indicating the pump unit Guide. Thereafter, proceed with paragraph 4.3 “Bleeding pump & system”
ran out of grease. in General manual EF1703.
Aborted cycles due control unit encountered successive
8. + = Successive low supply power dips in attempt to initiate pump motor, caused by;
voltage / bad wiring a.) Faulty battery (of vehicle). a.) Charge or replace battery (of vehicle).
b.) Faulty wiring (ground wire). b.) Check wiring. Replace or repair when necessary.
c.) Corroded pin-contact in electrical connectors. c.) Check connections at pump and cabin. Repair when necessary.
The pressure switch did not close during a grease cycle in
9. + = Faulty pressure switch primary line-A or –B while control unit noticed a deviant
circuit resistance over the pressure switch circuit, caused by;
a.) Faulty wiring or connectors. a.) Check wiring / connectors. Replace or repair when necessary. Proceed
with section 4.6.5 “Malfunction finding procedures” Gen. manual EF1703.
b.) Defective pressure switch. b.) Replace pressure switch.
Control unit detected a too low current draw to pump motor in
10. + = Successive pump combination with initial “No pressure line-A or -B” error,
open loads caused by;
a.) Interrupted wiring of motor (or internally). a.) Check wiring of motor. Replace or repair when necessary.
b.) Defective motor. b.) Check wiring faulty and resistance of the motor. Replace when necessary.
c.) Defective control unit. c.) Check control unit (i.e. corrosion). Replace control unit.
Control unit detected a too high current draw to pump motor
11. + = Successive pump over and aborted the attempted cycle, caused by;
current a.) Short circuit in wiring of motor. a.) Check the wiring of the motor. Replace or repair when necessary.
b.) Short circuit in motor. b.) Check wiring faulty and resistance of the motor. Replace when necessary.
c.) Drive-shaft obstructed. c.) Check the drive-shaft on obstruction. Replace or repair when necessary.
d.) Extreme low ambient temperature in combination with d.) Replace the grease in the reservoir and bleed the system with a ambient
non-suitable type of grease. temperature suitable grease.
e.) The pump motor current limit setting not suitable for e.) Increase the “Pump motor current limit” parameter setting.
extreme low ambient temperatures.
Control unit detected a too low current draw to 1st or 2nd coil of
12. + = Successive valve-1 the 5/2-way valve in combination with initial “system on
open loads, or; pressure before cycle” error, caused by;

a.) Short circuit in wiring to coil. a.) Check wiring. Replace or repair when necessary.
+ = Successive valve-2
b.) Defective coil. b.) Check on wiring faulty and resistance of coil. Replace when necessary.
open loads
Control unit detected a too high current draw to 1st or 2nd coil
13. + = Successive valve-1 of the 5/2-way valve in combination with initial “system on
over current, or; pressure before cycle” error, caused by;

a.) Short circuit in wiring to coil. a.) Check wiring. Replace or repair when necessary.
+ = Successive valve-2
b.) Defective coil. b.) Check on wiring faulty and resistance of coil. Replace when necessary.
over current
a.) No communication between Twin display & pump unit. a.) Check the purple communication wire no.6 between display & pump unit.
14. + = Communication error (pump connector pin no.6). Repair when necessary.
with control unit b.) No supply voltage at pump unit. b.) Check fuse & red power wire no.1 to pump connector no.1 and the black
ground wire no.2 to the pump connector no.2. Repair when necessary.
c.) Defective Twin-3 display. c.) When no issues found as stated in solution A or B, replace Twin-3 display.
Control unit encountered corrupted parameters during power Replace control unit.
15. + = Parameter checksum up and restored the production default setting in control unit.
error
Real Time Clock (RTC) battery low (<2.2V) at control unit. Battery is soldered to control unit, therefore would be impossible to replace.
16. + = Low RTC battery Normally battery is 3V and last for approx. 10-years. Replace control unit.
Control unit encountered a corrupted RTC causing events & Battery is soldered to control unit, therefore would be impossible to replace.
17. + = RTC faulty errors to be stored with inaccurate times & dates, caused by;
a.) Real Time Clock (RT) battery empty. a.) Replace control unit.
Control unit encountered an unknown error, caused by;
18. + = Unknown cause a.) Display connected to a Twin-2 pump unit. a.) Control unit does not provide such additional info as Twin-3 pump units.
b.) An error cause that is not listed. b.) Replace pump or control unit in attempt for clearing the error code.

Groeneveld Transport Efficiency Canada, LTD. Groeneveld Transport Efficiency United States, Inc. Groeneveld Pacific West, LLC.
8450 Lawson Road, unit 5, Milton ON, L9L 0J8 1130 Industrial Parkway N, Brunswick OH, 44212. 1089 Valentine Ave. S.E., Pacific WA, 98047
Phone: 905-875-1017 / Fax: 905-875-2125 Phone: 330-225-4949 / Fax: 330-225-5213 Phone: 253-863-3700 / Fax: 253-863-3131
Toll free: 1-800-263-1760 Toll free: 1-800-856-7283

Website: www.groeneveld-group.com

Part #: F211688

You might also like