Operation and Maintenance Manual – PBX System
Table of Content
PART A
PART B
________________________________________________________________________________
Science & Technology Parks at Tseung Kwan O Industrial Estate
Operation and Maintenance Manual – PBX System
FOR
Science & Technology Parks at Tseung Kwan O Industrial Estate
PART A
________________________________________________________________________________
Alcatel-Lucent OmniPCX Enterprise
Communication Server
Maintenance
Table Of Content
________________________________________________________________________________
Chapter 2 Hardware description
The two Ethernet interfaces must be connected to two interfaces of the same switch unit. This switch
[ A1 ] PBX Board Layout and Indicator
unit requires a special configuration. This switch unit must support the load balancing feature.
Ethernet load balancing must be activated via the netadmin tool (see: netadmin - Operation - Ethernet
Redundancy).
Note:
The SLANX4 board does not support load balancing.
8AL91027USAJ - Ed. 01 - March 2019 - OXE System: Common Hardware Installation Manual 21/106
Chapter 2 Hardware description
Name Function
LAN2 • Green: LAN port 2 operating correctly (the dual Ethernet feature is
configured)
• Flashing green: Ethernet traffic detected, flash speed increases with
traffic
UNIT 1 Green: LAN switch 1/2/3/4 interface operating correctly (flashes to indicate
traffic)
UNIT 2
UNIT 3
UNIT 4
2.2.3.1 Functions
The GD-3 board offers the following features:
• Media Gateway controller
8AL91027USAJ - Ed. 01 - March 2019 - OXE System: Common Hardware Installation Manual 22/106
Chapter 2 Hardware description
Name Function
1 2 3 4
Figure 2.8: Switch Settings
8AL91027USAJ - Ed. 01 - March 2019 - OXE System: Common Hardware Installation Manual 24/106
Chapter 2 Hardware description
LED meanings:
Name Function
AIS Excessive number of "1"s in the 2 Mbits bit stream (red LED on if
there is an alarm)
8AL91027USAJ - Ed. 01 - March 2019 - OXE System: Common Hardware Installation Manual 30/106
Chapter 10 Power connections
[ A2. ] PBX Battery
J1 connector
(for system connection)
2. Open the unit by removing the four screws (ST3.5x32) with a screwdriver (Phillips PH2).
3. Insert the batteries in the open unit as follows (also see the figure below):
a. If 2 batteries are to be used, the slots B1 and B3 are used.
b. If three batteries are to be used, the slots B1, B2 and B3 are used.
Battery positions
B3
B2
B1
4. Connect the negative (black) terminals of the batteries as described below (and shown in the figure
below).
+ +
- -
B3 B3
+
-
B2 B2
+ +
- -
B1 B1
2 Batteries 3 Batteries
8AL91027USAJ - Ed. 01 - March 2019 - OXE System: Common Hardware Installation Manual 86/106
Chapter 10 Power connections
5. Connect the positive (red) terminals of the batteries as described below (and shown in the figure
below).
+ +
- -
B3 B3
+
-
B2 B2
+ +
- -
B1 B1
2 Batteries 3 Batteries
J2 connector
(for extension)
J1 connector
(for system connection)
2. Open the unit by removing the four screws (ST3.5x32) with a screwdriver (Phillips PH2).
3. Insert the three batteries in the open unit, into the positions B1, B2 and B3 (see the figure below).
8AL91027USAJ - Ed. 01 - March 2019 - OXE System: Common Hardware Installation Manual 87/106
[ A3. ] Backup
Chapter 5 Procedure
Swinst
Option 1 Backup mao, voice guides and accounting data triggers mao, voice guide and
accounting backup (mao, vg and acc files)
Note:
Dynamic voice messages are automatically backed up, the tool also offers to back up specific voice messages
(custom directory). However, generic and standard voice messages (available on the voice guide CD-ROM) are
not backed up.
Option 3 Backup accounting data, triggers an accounting data backup operation (acc file).
Option 6 Backup traffic history, triggers a traffic analysis backup operation (obstraf file).
Option 7 Backup Acd config & statistic data, triggers a traffic analysis backup operation
(acd file).
Option 8 Backup 4645 data, triggers a 4645 voice mail data backup operation - messages,
mailboxes and greetings (eva-msg file).
Option 9 Backup 4645 data without messages, triggers a 4645 voice mail data backup
operation - except for received messages - (eva file).
Option 11 Backup linux ( unix ) site specifics data, triggers a backup operation of the
cho-dat file (system-specific Linux data).
Note:
OPS file backup operations are managed from option: OPS Configuration on page 134.
5.2.4.1.2 Immediate Backup on Network
Select the data to backup (see: Immediate Backup on CPU Disk on page 128).
Enter the name of the remote Communication Server.
If this name is not declared in the Communication Server host file, enter the IP address of the remote
Communication Server.
When a "backup on network" has been saved, for any new backup of this type, the application offers
the last used address as the default setting.
Example:
Backup on network
your choice ==> 3
FOR
Science & Technology Parks at Tseung Kwan O Industrial Estate
PART B
________________________________________________________________________________
Alcatel-Lucent 8058s Telephone User Quick Reference Guide
To Retrieve { Clear}
接收 Press to erase the current message 删除本讯息
{ Call }
按 to call the sender 致電寄件者
{ Sent Txt }
to reply the sender 回覆寄件者