Troubleshooting
Symptoms of Trouble, Causes, and Corrective Measures
High Solute High solute passage at normal permeate flow may have different causes.
Passage and a. Leaking O-Ring
Normal Permeate Leaking O-rings can be detected by the probing technique (see the Probing section
Flow in Troubleshooting - System Tests (Form No. 45-D01641-en). Inspect O-rings of
couplers, adapters and end plugs for correct installation and as-new condition.
Replace old and damaged O-rings. Also see Loading of Pressure Vessels -
Interconnector Technology (Form No. 45-D01604-en).
O-rings may leak after exposure to certain chemicals, or to mechanical stress, e.g.,
element movement caused by water hammer. Proper shimming of the elements in a
pressure vessel is essential to minimize the wear to the seals (see Shimming
Elements (Form No. 45-D01057-en) ). Sometimes, O-rings have simply not been
installed, or they have been improperly installed or moved out of their proper
location during element loading. For replacement O-rings, see Table 1 in Loading of
Pressure Vessels - Interconnector Technology (Form No. 45-D01604-en).
b. Telescoping
FilmTec™ Elements can be mechanically damaged by an effect called telescoping,
where the outer membrane layers of the element unravel and extend downstream
past the remaining layers. A modest telescoping does not necessarily damage the
membrane, but in more severe cases the glue line and/or the membrane can be
ruptured.
The operating conditions that lead to excessive pressure drop are detailed in High
Pressure Drop (Form No. 45-D01652-en). Telescoping damage can be identified by
probing and by a leak test (see Vacuum Decay Test (Form No. 45-D01645-en) ).
Replace the damaged element(s) and correct the causes.
Oxidation damage may also occur by disinfecting with oxidizing agents, when pH
and temperature limits are not observed, or when the oxidation is catalyzed by the
presence of iron or other metals (see Sanitizing RO & NF Membrane Systems
(Form No. 45-D01629-en) ). In this case, a uniform damage is likely.
b. Leak
Severe mechanical damage of the element or of the permeate tubing can allow feed
or concentrate to penetrate into the permeate, especially when working at high
pressures. The vacuum test will show a distinct positive response. Possible causes
are discussed in the next section.
Excerpt from FilmTec™ Reverse Osmosis Membranes Technical Manual (Form No. 45-D01504-en), Chapter 8, "Troubleshooting."
Have a question? Contact us at: All information set forth herein is for informational purposes only. This information is general information and may differ from that
based on actual conditions. Customer is responsible for determining whether products and the information in this document are
www.dupont.com/water/contact-us
appropriate for Customer's use and for ensuring that Customer's workplace and disposal practices are in compliance with
applicable laws and other government enactments. The product shown in this literature may not be available for sale and/or
available in all geographies where DuPont is represented. The claims made may not have been approved for use in all countries.
Please note that physical properties may vary depending on certain conditions and while operating conditions stated in this
document are intended to lengthen product lifespan and/or improve product performance, it will ultimately depend on actual
circumstances and is in no event a guarantee of achieving any specific results. DuPont assumes no obligation or liability for the
information in this document. References to “DuPont” or the “Company” mean the DuPont legal entity selling the products to
Customer unless otherwise expressly noted. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. No freedom from infringement of any patent or
trademark owned by DuPont or others is to be inferred.
DuPont™, the DuPont Oval Logo, and all trademarks and service marks denoted with ™, ℠ or ® are owned by affiliates of
DuPont de Nemours Inc. unless otherwise noted. © 2020 DuPont.