A25D 4x4 Volvo

Sensor, oil level, transmission, too high voltage

SAE code: MID 130 PID 124 FMI 3


Conditions:
The transmission control unit (T-ECU) registers: voltage too high (EB4)
Possible cause: Reaction from control unit:

¡ Open circuit on frame ground cable ¡ 2F4208, oil level in transmission


¡ Open circuit on signal line
¡ Frame ground cable short-circuited to voltage
¡ Signal line short-circuited to 5 V or higher voltage
¡ Sensor not connected (open circuit)
¡ Defective sensor

Symptom/malfunction: Troubleshooting information:

¡ Monitoring stops ¡ Electrical cabling and connectors, checking


¡ Information display unit shows minus sign for level ¡ SE4203, description and measuring
in transmission

Sensor, oil level, transmission, too low voltage

SAE code: MID 130 PID 124 FMI 4


Conditions:
The transmission control unit (T-ECU) registers: voltage too low (EB4)
Possible cause: Reaction from control unit:

¡ Signal line short-circuited to frame ground ¡ 2F4208, oil level in transmission


¡ Defective sensor
¡ Low feed voltage to sensor

Symptom/malfunction: Troubleshooting information:

¡ Monitoring stops ¡ Electrical cabling and connectors, checking


¡ Information display unit shows minus sign for level ¡ SE4203, description and measuring
in transmission

Sensor, oil level, transmission, other malfunction

SAE code: MID 130 PID 124 FMI 11


Conditions:
The transmission control unit (T-ECU) registers: other malfunction than too high/low voltage (EB4)
Possible cause: Reaction from control unit:

¡ ¡ 2F4208, oil level in transmission


Symptom/malfunction: Troubleshooting information:

¡ Monitoring stops ¡ Electrical cabling and connectors, checking


¡ Information display unit shows minus sign for level ¡ SE4203, description and measuring
in transmission