Professional Documents
Culture Documents
Kopievondffa b10531 00pn Tech Brenus 144
Kopievondffa b10531 00pn Tech Brenus 144
device development.
Industrial communication that optimizes
flexibility, efficiency, and performance.
siemens.com/profinet-technologie
The Industrial Ethernet standard …
PROFINET
nodes PROFIsafe
nodes
20.9 m 22 million
20 million 10 million
16.4 m 8.9 m
18 million 9 million
16 million 8 million
6.95 m
12.8 m 14 million 7 million
5.40 m
12 million 6 million
10 million 5 million
8 million 4 million
6 million 3 million
4 million 2 million
2 million 1 million
2004
2004 2005
2005 2006
2006 2007
2007 2008
2008 2009
2009 2010
2010 2011
2011 2012
2012 2013
2013 2014
2014 2015
2015 2016
2016 2017
2017 2018
2018 2009 2010 2011 2012 2013 2014 2015 2016 2017 2018
Steeply rising growth rates: PROFINET is the leading Industrial Ethernet communication standard.
2
… for maximum viability
into the future
PROFINET and OPC UA in the same network
Thanks to its lean and efficient protocol, PROFINET is ideal
Plant
for cyclic and real-time I/O data exchanges on the field
level. OPC UA brings its strengths to bear primarily in the
vertical communication of acyclic data. OPC UA is also
suitable for controller-to-controller communication.
The PROFIsafe profile is used for failsafe communication on
the field level as well as for controller-to-controller commu-
nication with PROFINET and OPC UA. Machine Machine
3
PROFINET technology
from Siemens …
Innovative and well proven Development kit for ERTEC 200P-2
In its role as a PI member, Siemens has been actively driving The development kit includes an evaluation board with
PROFINET development since the very beginning. Siemens’ sample applications, making it possible to carry out
technology components benefit from this collective commissioning in very short order. The PROFINET stack
knowledge. They have also been proven in countless ships in source code, including the eCos open-source
products in the field, they help to maximize performance, real-time operating system, all development tools, analysis
and they can be scaled to your specific requirements. programs, and documentation. The ERTEC ASICs make it
possible to implement RT (real-time) and IRT (isochronous
Moreover, Siemens competence centers will advise you in
real-time) field devices. The integrated switch lets you build
choosing the right technology component for your device,
field devices with two ports.
offer training opportunities, and support you throughout
the entire development period all the way to successful
Functions:
certification.
• Isochronous mode
• Shared device for 4 IO controllers
ERTEC 200P-2 – the path to the fastest PROFINET
• S2 system redundancy
The ERTEC 200P-2 (Enhanced Real-Time Ethernet Control-
• PROFINET performance upgrade with
ler) is setting new standards in communication. Designed
a minimum cycle time of 125 μs
for cycle times of only 125 μs, the performance upgrade
• MRP/MRPD
for PROFINET has been integrated into the ERTEC 200P-2.
• Regular updates free of charge
With its 250 MHz ARM 9 CPU and an integrated IRT
• The latest technology certificate
(isochronous real-time) switch, field devices can thus
be implemented that meet the highest performance
standards. The smaller chip size simplifies integration
into compact field devices. In addition, the CPU lets you
integrate your own applications, eliminating the need
for an external host CPU, depending on the application.
ERTEC 200P-2
Integrated IRT switch 2-port
Integrated PHYs ✓
Parameterizable IOs,
96
general-purpose IOs
4
… for efficient device and
controller development
PROFINET driver for controllers CP 1625 controller development kit
Cost-effective components are an enormous competitive The CP 1625 controller development kit is suitable for both
advantage especially when mass-producing machines. standalone and host operation.
Users often employ control software they’ve developed
• Standalone operation: PN Stack and application
themselves. The individual application is often implement-
run on the SOC1.
ed on standard PCs for reasons such as performance,
Host operation: Application runs on the PC or,
flexibility, and cost. Thanks to a conventional Ethernet
for example, ARM – the stack runs on the CP 1625.
interface, the PROFINET driver supports these independent
developers and does not require any special hardware.
DK-16xx PN IO development kit for CP 1604 / CP 1616
Since the PROFINET driver ships in source code, you can and DK-HN PN IO development kit for CP 1626
port your own solutions to different operating systems The development kits (driver and IO base software) for
and hardware platforms. As a result, the PROFINET driver the CPs are available in the source code as PROFINET IO
can also be ideally used in embedded systems for your controllers and IO devices under Linux for porting to any
own control solutions. Engineering and configuration are PC-based operating system with the IO Base interface.
easy and take place via an open XML interface without This applies to both IRT operation and RT operation.
any engineering tools. The long-proven SIMATIC PROFINET The device can also act as the PROFIsafe device with the
stack lies at the heart of the solution. appropriate software upgrade.
The PROFINET driver is suitable for both simple applica- A railway-approved variant, the CP 1604 EEC, also exists
tions, such as individual PROFINET lines, and complex for the CP 1604.
machines. It supports PROFINET RT for cycle times above
1 ms, as per the standard Ethernet interface. Alternatively,
PROFINET IRT can also be used for cycle times above 500 μs
in combination with the CP 1625 controller development kit.
PROFINET-ConfigLib
PROFINET networks have to be
TIA Portal Engineering
planned, which can be done via
TIA Portal for the PROFINET driver.
No license is required. ConfigLib
is an independent API for creating
PROFINET hardware engineering
projects. Both RT and IRT projects
can be set up, and ConfigLib handles
Real PROFINET application 3rd party Engineering + PNConfigLib IRT Controller
the planning algorithm.
5
Support for
easy development …
PROFIsafe starter kit
Transmission channels as pure black channels for PROFIsafe Functional safety is a serious consideration in automation.
Safety Standard Standard Safety The PROFIsafe starter kit can be used to easily implement
application application application application failsafe field devices. Sample implementations for easy
e.g. diagnosis e.g. diagnosis connection to ERTEC platforms are available for the
PROFIsafe stack.
PROFIsafe PROFIsafe PROFIsafe F messages between an F host (safety controller) and its F
layer layer layer device are transported as payloads in PROFINET telegrams.
Standard Standard
The PROFIsafe protocol eliminates the need for the user to
protocol protocol evaluate the safety of his individual backplane bus system
Black
or other channels beyond PROFINET. It therefore ensures
Channel the functional safety of the entire path, from the sender of
an F signal, such as an F module in the remote bus termi-
nal, to the receiver, the F host, and vice versa. This is
achieved by additional safety measures in the F messages.
PROFINET Module
Ti
sync
Clock
T0
PD-Setpoint
Telegramm REG M
cyclic data
Cyclic data
interface
PROFINET device stack
PROFINET ASIC
PD-Actvalue
PN Telegramm
Z E
PD-Parameter
Channel
acyclic data
Acyclic data
interface
Vendor-
PD-Parameter Parameter
PROFINET PROFIdrive
Interface Layer
PROFIdrive sample
Drive
applications as free
downloads
6
… and certification
GSDML Development
Certification
Product certified!
Comprehensive consulting prior to starting the development project is particularly important for an efficient and successful development
processes. The final step in field device development is certification.
7
Find the right technology
solution for your
application:
• Development packages
• ERTEC ASICs
• PROFINET Drivers
• Global support and certification
Published by
Siemens AG 2018
Digital Factory
P.O. Box 48 48
90026 Nuremberg
Germany
Article No. DFFA-B10531-00-7600
Printed in Germany
Dispo 06334
gB180244 BR 08181.0
Subject to changes and errors. The information given in this document
only contains general descriptions and/or performance features which
may not always specifically reflect those described, or which may
undergo modification in the course of further development of the
products. The requested performance features are binding only when
they are expressly agreed upon in the concluded contract.
In order to protect plants, systems, machines and networks against
cyber threats, it is necessary to implement – and continuously
maintain – a holistic, state-of-the-art industrial security concept.
Siemens’ products and solutions only form one element of such a
concept. Further information about Industrial Security you will find at:
https://www.siemens.com/industrialsecurity