Digital Speed Controller

Instruction Manual
YTMC-2135

W
EB
TE
NS
IO
N
CO
NT
RO
LL
ER

EUNTAY ELECTRIC CO., LTD


TEL: 886-2-8209817 FAX: 886-2-82090327

E-mail:inter-service@euntay.tw
http://www.euntay.tw
1 Panel Face Plate Description:

2 Production Operation:

Presskeys, After set up ,press SET ,then complete


change%,at this time % action. PV value display number
PV value display flashing stop。

3 parameter setup procedure:

Press P & SET keys at Press SET key, Press  After change complete
the same time,continue the parameter keys,change Press SET again ,and then
for 5 seconds to enter SELE flashes。 parameter move to the next
parameter setup status。

If not to change this If in the Parameter(not Completion→mov


parameter ,Press P to flashing),after 10 e back to
move to the next seconds ,automatic moves production
out parameter setup status。
4 Parameters
func

P+SET

FNAIN SErI INSD


5 Parameters Table
Control mode: <0> ratio linkage
Default Setting
Symbol Symbol Description Explanation
Value Range
0= PROP
Control mode
0 1=REMOTE 0:ratio linkage control mode
selection
(0206H) 2=DRCIP

Speed increasing time 5.0S 0.1~600.0S Only effective in IN1


(0208H)

Speed reducing time 5.0S 0.1~600.0S Only effective in IN1


(020AH)
When panel %=100%,
(IN1) linear speed
100% 0~500.00% Adjust this value to make
input ratio increase
(020CH) linear speed 1:1
When panel %=100%,
(IN2) linear speed
100% 0~500.00% Adjust this value to make
input ratio increase
(020EH) linear speed 1:1
F→V conversion
(ENA1) frequency
18KHZ 1K~36KHZ (for example , set at 18KHZ
input maximum value
(0210H) means 18KHZ=10Voutput)
When panel %=100%,
(ENA1) frequency
100% 1~500.00% Adjust this value to make
increase value
(0212H) linear speed 1:1

Pressure difference -5.00V~+5.00 The voltage value at the


0V
setting V starting point
(0214H)

Output OUT1 display 1.0~200.00 The production speed at 10V


1 time
ratio time /10V=SPR,SRC=0 effective
(0216H)
0=OUT1
1=IN1(V)
OUT1,IN1,IN 2=IN2(V)
PV value display
2,FRG,UART, 3=FRG(frequency)
source selection
(0218H) SEOUT 4=UART
5=SEOUT(Communication is
not blinking)
Positive angle relay When OUT1 voltage higher
10V 0~10.00V
action point then this voltage , Hi relay
(0224H) action
When OUT1 voltage lower
Negative angle relay
0V 0~10.00V then this voltage , Low relay
action point
(0226H) action
The Ratio value (%, SV) can’t
The High Limit of Ratio
200% 0~500.00% be larger than the setting
(%, SV)
(0228H) value of SVHI
The Ratio value (%, SV) can’t
The Low Limit of Ratio
0% 0~500.00% be smaller than the setting
(%, SV)
(022AH) value of SVLO

Control mode: <1> electric speed adjustment


0=PROP 1:electric speed adjustment
Control mode
1 1=REMOTE control mode (shall short
selection
(0206H) 2=DRCIP outside terminal IN1 and 10V)

Speed increasing time 5.0S 0.1~600.0S Only effective in IN1


(0208H)

Speed reducing time 5.0S 0.1~600.0S Only effective in IN1


(020AH)
When panel %=100%,
(IN1) linear speed
100% 0~500.00% Adjust this value to make
input ratio increase
(020CH) linear speed 1:1
When panel %=100%,
(IN2) linear speed
100% 0~500.00% Adjust this value to make
input ratio increase
(020EH) linear speed 1:1
F→V conversion
(ENA1) frequency
18KHZ 1K~36KHZ (for example , set at 18KHZ
input maximum value
(0210H) means 18KHZ=10Voutput)
When panel %=100%,
(ENA1) frequency
100% 0~500.00% Adjust this value to make
increase value
(0212H) linear speed 1:1

Pressure difference -5.00V~+5.00 The voltage value at the


0V
setting V starting point
(0214H)

Output OUT1 display The production speed at 10V


1 1.0~50.00
ratio /10V=SPR,SRC=0 effective
(0216H)
OUT1 0=OUT1
PV value display
IN1 1=IN1(V)
source selection
(0218H) IN2 2=IN2(V)
FRG 3=FRG(frequency)
UART 4=UART
SEOUT 5=SEOUT(Communication is
not blinking)
When OUT1 voltage higher
Positive angle relay
10V 0~10.00V then this voltage , Hi relay
action point
(0224H) action
When OUT1 voltage lower
Negative angle relay
0V 0~10.00V then this voltage , Low relay
action point
(0226H) action

Control mode: <2> position change control


0=PROP
Control mode 2:position change control
2 1=REMOTE
selection mode
(0206H) 2=DRCIP
When panel %=100%,
(IN1) linear speed
100% 0~500.00% Adjust this value to make
input ratio increase
(020CH) linear speed 1:1
F→V conversion
(ENA1) frequency
18KHZ 1K~36KHZ (for example , set at 18KHZ
input maximum value
(0210H) means 18KHZ=10Voutput)
When panel %=100%,
(ENA1) frequency
100% 0~500.00% Adjust this value to make
increase value
(0212H) linear speed 1:1

Output OUT1 display The production speed at 10V


1 1.0~999.9
ratio /10V=SPR,SRC=0 effective
(0216H)
0=OUT1
OUT1
1=IN1(V)
IN1
2=IN2(V)
PV value display DR
3=FRG(frequency)
source selection FRG
(0218H) 4=UART
UART
5=SEOUT(Communication is
SEOUT
not blinking)
The central point The central point could be set
-180°~0~+18
setting of potential 0 within the range (-180° ~

(021AH) meter +180°)
The correction for
The compensation for the
potential meter
30% 0~100% deviation of potential meter’s
feedback signal’s
(021CH) central point
deviation
When line speed = 0, the
Basic correction of
feedback value multiplied by
potential meter’s 2V 0~5V
“ ” for correcting
(021EH) feedback signal
deviation
When OUT1 voltage higher
Positive angle relay
+150° 0~+180° then this voltage , Hi relay
action point
(0220H) action
When OUT1 voltage lower
Negative angle relay
-150° 0~-180° then this voltage , Low relay
action point
(0222H) action
The Ratio value (%, SV) can’t
The High Limit of Ratio
200% 0~500.00% be larger than the setting
(%, SV)
(0228H) value of SVHI
The Ratio value (%, SV) can’t
The Low Limit of Ratio
0% 0~500.00% be smaller than the setting
(%, SV)
(022AH) value of SVLO
Communication parameters (SERI)
The source selection
(0)TB 0: Terminal Control
of operation
(1)rs485 1: Communication Control
(0250H ) instruction
0: Terminal Control
(0)TB
The source selection 1: Communication Control
(1)RS485
of analog signal 2: Terminal Control, but “SV”
(0252H ) (2)TB-RS
is controlled by RS-485
The setting of
communication 0 0~31 0 ~ 31
(0254H ) address
Transmission speed could be
The setting of 4800,9600,
19200 set as:
transmission speed 19200
(0256H ) 4800, 9600, 19200
1: Non-parity
NO,Even,
Parity setting 2: Even-parity
Odd
(0258H ) 3: Odd-parity
The setting of The delay time between
communication delay 15 ms 5~65ms command message and reply
(025AH ) time message
0: Communication abnormal
The corresponding format and communication
action’s setting for interrupt overtime, controller
0~2
abnormal stop running
(025CH )
communication 1: Communication format is
not correct, controller stop
running; communication
format is correct, but interrupt
time is over 3 sec., controller
stop running
2: Communication format is
abnormal and communication
interrupt is over-time,
controller continue to run
Password.(INSD)
1234: Reset to default
Parameter cipher 0 0~9999 1 ~ 9999: Can’t change
parameter

※ Communication is option (MODEL:YTMC-2135-V3-…-RS)

※When multiple of YTMC-2135-RS are


communicated in parallel, the switch of
terminal resistor of the last controller
must be switched to “ON”, the switch
position is showed in the following figure
6 Communication parameter control and monitoring address
control Data Registers
1. (0280H): BIT0=P1 0=OFF 1=ON
BIT1=P2 0=OFF 1=ON
BIT2=P3 0=OFF 1=ON
BIT4=RESTER
2. (0282H): IN1 terminal input value received communications sent by the host (0~4095)

Monitoring Data Registers


1. (0290H): BIT0=P1 0=OFF 1=ON
BIT1=P2 0=OFF 1=ON
BIT2=P3 0=OFF 1=ON
BIT3=LOCK 0=OFF 1=ON
2. (0291H): BIT0=HI RELAY1 ACTIVE 0=OFF 1=ON
BIT1=LOW RELAY1 ACTIVE 0=OFF 1=ON
3. (0293H): BIT0=CRC16 CODE ERROR
BIT1=SERIAL BRK OE PE FE ERROR
BIT3=SERIAL READ/WRITE ADDRESS ERROR
BIT4=SERIAL FUNCTION ERROR
BIT5=SERIAL TIME ERROR TIME>5S
BIT7= SERIAL RXD BEARK TIME>3S
4. (0294H): IN1 Input Signal (0~4095)
5. (0296H): IN2 Input Signal (0~4095)
6. (029CH): OUT1 Output Signal (0~4095) ※:029CH.15=0(+)
7. (029EH): OUT2 Output Signal (0~4095)
8. (02A0H): Frequency signal (0~4095)
10.(02A4H): Display value (PV) (10D) ※:02A4H.15=0(+)
11.(0202H): Setpoint (SV) 0~500.00% (10D)
7 Wiring Diagram

NFB
POWER SOURCE
1P 185~235Vac
ALARM

Max250Vac1A

Speed increase P1
pushbutton COM
Speed decrease P2
pushbutton COM
Zero P3
pushbutton COM

CPU
A/D

CPU
D/A
NFB
POWER SOURCE
1P 185~235Vac
ALARM

Max250Vac1A

P1
Position change sensor COM
uide of compensation signals P2
(opposite polaruty) COM
Speed increase and decrease) P3
COM

analog input of main line speed


D3
Position change sensor loop bac

CPU D2
A/D DR
D1
YTM-01

CPU
D/A

8 Dimension