PLUMBING NOTES:
1. GRADES OF HORIZONTAL PIPINGS
RUN ALL HORIZONTAL PIPINGS IN PERFECT ALIGNMENT AND AT A
FORM GRADE NOT LESS THAN TWO PERCENT ( 2% )

2. CHANGE IN DIRECTION
ALL CHANGE IN DIRECTION SHALL BE MADE BY APPROPRIATE USE
OF FORTY-FIVE DEGREES (45° ) WYES, LONG SWEEP QUARTER
BEND, SIXTY-EIGHT OR SIXTEENTH BEND, WHEN THE CHANGE OF
FLOW IS FROM HORIZONTAL TO VERTICAL, A SINGLE BEND 1/8
BEND COMBINATION MAY BE USED ON VERTICAL STACKS, AND
SHORT QUARTER BENDS MAY BE USED IN VENT PIPES.
1600

3. PROHIBITED FITTINGS
NO DOUBLE HUB OR TEE BRANCH SHALL BE USED ON HORIZONTAL
SOIL AND WASTE LINES, THE DRILLINGS AND TAPPING OF HOUSE
DRAIN, WASTE OR VENT PIPES AND USE OF SADDLE HUB AND
LEGEND BEND ARE PROHIBITED.

PT BLADDER/PNEUMATIC TANK 4. PIPE CLEAN-OUTS


E ELECTRIC MOTOR CLEAN-OUTS ARE REQUIRED UNDER THE FOLLOWING
CONDITIONS:
P PUMP
a.) EVERY CHANGE OF HORIZONTAL DIRECTION EXCEEDING
U UNION PATENTE TWENTY TWO AND ONE-HALF DEGREES ( 22 1/2" )
FTV FOOT VALVE b.) ONE AND ONE-HALF METERS ( 1.50m.) INSIDE THE PROPERTY
PLAN FV FLOAT VALVE LINES BEFORE THE HOUSE DRAINAGE CONNECTION.
PP PRIMING PORT c.) EVERY FIFTEEN METERS ( 15.00m.) IN HORIZONTAL RUN OF
CB CATCH BASIN PIPES.
CDP CONCRETE DRAIN PIPE d.) AT THE END OF ANY HORIZONTAL PIPE LINES.
2600 CV CHECK VALVE 5. THE DIGESTION CHAMBER OF SEPTIC VAULT MUST BE
HB HOSE BIBB WATERPROOFED.
1400 900 FD FLOOR DRAIN
6. NOT LESS THAN 0.30 METER OF AIR SPACE MUST BE LEFT
PPR CWL POLYPROPYLENE COLD WATER LINE BETWEEN THE TOP OF THE SEWAGE AND THE UNDER PART OF
VAULT ROOF SLAB.
PPR CWR POLYPROPYLENE COLD WATER RISER
7. NO SEPTIC VAULT SHALL BE CONSTRUCTED UNDER THE BUILDING.
GV GATE VALVE 8. ALL PLUMBING WORKS SHALL BE UNDER THE SUPERVISION OF A
LICENSED MASTER PLUMBER AND A LICENSED PLUMBING
SCUM LEVEL
MH MANHOLE CONTRATOR.

100MM Ø SANITARY TEE PVCDS POLYVINYL CHLORIDE DOWNSPOUT


PVCDP POLYVINYL CHLORIDE DRAIN PIPE CO CLEAN OUT

PVCSP POLYVINYL CHLORIDE SOIL PIPE


2100

DIGESTIVE LEACHING
C H A M B E R CHAMBER PVCVAC POLYVINYL CHLORIDE VENT. ACROSS
CEILING

10MMØ HORIZONTAL BAR PVCVP POLYVINYL CHLORIDE VENT. PIPE


SPACED @ 125MM
BOTHWAYS
2.00% 2.00% PVCVS POLYVINYL CHLORIDE VENT STACK
3-10MMØ HORIZONTAL
BAR PVCVTR/W POLYVINYL CHLORIDE VENT
10MMØ TRANSVERSE BAR TROUGH ROOF/WALL

PVCWP POLYVINYL CHLORIDE WASTE PIPE


SECTION
PVCWS POLYVINYL CHLORIDE WASTE
STACK

SEPTIC TANK DETAIL RD


UD
ROOF DRAIN
URINAL DRAIN
WC WATER CLOSET
LAV LAVATORY
KS KITCHEN SINK

PTR NO.: REPUBLIC ACT 9266 PROJECT TITLE: SHEET CONTENT: REVISION: DATE: DRAWN: SHEET NO.:

PTR NO.: ALL DRAWINGS, DOCUMENTS ARE THE


PROPERTY OF THE OWNER AND DESIGNED:
DATE: CANNOT BE COPIED, REPRODUCE,
USED IN WHOLE NOR IN PART WITHOUT
PLACE: THE WRITTEN CONSENT OF THE
AS SHOWN
CHECKED:
2
TIN:
OWNER, VIOLATION OF SUCH LAW IS
SUBJECTED TO ADMINISTRATIVE /
P-2
MASTER PLUMBER CRIMINAL LIABILITIES. LOCATION: PANG PANG, SORSOGON APPROVED: OWNER