PHOTOGRAPH CAUSE IDEAL SOLUTION

Observation: If working with multiple pours


during execution is the choice,
The joint then the proper shear key must
between the be provided in the center of the
existing pour and structure along the length so
that the bond is well maintained.
the new pour, Still, to avoid leakage of any
which is known slurry from the outer surface, a
as the small formwork shutter should be
continued from the bottom of the
construction existing structure will prevent it.
joint, is not well If a solution is to be obtained
maintained after concreting, then a suitable
grout mixture of GP2 has to be
grouted using one of the grouting
techniques so that any further
damage is created
Observation: The As the situation is
joint area is where
pertained post
foam provided
during shuttering is concreting, a suitable
provided too deep and strong mortar has
hence the foam is to be prepared and
got stuck in the
applied at the junction
structure, and the
binding wire is to bring back to surface
exposed out thickness, and also the
primary reason can binding wire will be
be of
covered with
reinforcement cage
shifted outside appropriate plaster
thickness
Observation:
Curing is not
Liner system of
carried out, which
leads to shrinkage
curing or
cracks because application of
hydration reactions
are already curing
started since the
pour of concrete
compound has to
be carried out if
else the
structure
reliability comes
down
Observation: The Appropriate cover has
main reinforcement
bar has come out, to be checked at
and the binding shutter bottom
wire is tied out.
middle and center so
This is caused due
to reinforcement that reinforcement
cage shifted cage is according the
given dimensions that
confirms that there is
no shift of further
reinforcement