You are on page 1of 16

Department of Electrical and Electronic Engineering (EEE)

Summer 2021
Lab Report

Experiment Number: 02

Experiment Name: Performance Analysis of Short Transmission Line.

Course Title: Electrical Power Systems.

Course Code: EEE304

Section:01

Student Name: Md.Mahim

ID: 2018-1-80-016

Lab Instructor: Dr. Khalid Imtiaz Saad


Assistant Professor
Department of Electrical and Electronic Engineering

Date of performance: 28.07.2021

Date of submission: 03.08.2021


Answer 2 & 3

Circuit Diagram & Simulated result:


For,
Resistive Load:

Figure 01
Figure 02
Figure 03
For Inductive Load

Figure 04
Figure 05

Figure 06
For Capacitive Load,

Figure 07
Figure 08

Figure 09
Answer 4
Verification of simulation results:

Load type Value of 𝑟 Calculated Simulated Error %


(Ω/km) voltage voltage (|𝑉𝑅𝐶−𝑉𝑅𝑆||𝑉𝑅𝑆|×100%)
regulation, 𝑉𝑅𝐶 regulation, 𝑉𝑅𝑆

Resistive 0.04 52.65% 59.8% 11.95%

Inductive 0.04 85.34% 86.63% 1.4%

Capacitive 0.04 67.36% 67.36% 8.97%

Answer 5
From the verification of simulation result we see that calculated voltage regulation of resistive load is
52.65%, for inductive load calculated voltage regulation is 85.34% and capacitive load calculated voltage
regulation is 67.36%. For a resistive load, if the resistance of a short transmission line is increased, the
voltage regulation increases.