Professional Documents
Culture Documents
2016
Report No.: ERY1608P05R9
Model: FT-991A
TEST REPORT
For
Model : FT-991A
FCC ID : K6620575X50
Prepared for
YAESU MUSEN CO., LTD.
Tennozu Parkside Building 2-5-8 Higashi-Shinagawa,
Shinagawa-ku, Tokyo 140-0002 JAPAN
Prepared by
SGS RF Technologies Inc.
3-5-23, Kiyatamata, Tsuzuki-ku, Yokohama, 224-0021, Japan
Telephone: +81+(0)45- 550-3520
FAX: +81+(0)45- 592-7506
This document is issued by the Company subject to its General Conditions of Service printed overleaf,
available on request or accessible at www.sgs.com/terms_and_conditions.htm and, for electronic
format documents, subject to Terms and Conditions for Electronic Documents at
www.sgs.com/terms_e-document.htm. Attention is drawn to the limitation of liability,
indemnification and jurisdiction issues defined therein. Any holder of this document is advised that
information contained hereon reflects the Company’s findings at the time of its intervention only and
within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client
and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full,
without prior written approval of the Company. Any unauthorized alteration, forgery or falsification
of the content or appearance of this document is unlawful and offenders may be prosecuted to the
fullest extent of the law.
SGS RF Technologies Inc. is managed to ISO17025 and has the necessary knowledge and test
facilities for testing according to the referenced standards. The test results in this report apply only
to the sample tested.
Table of contents
1 General information ...................................................................................................................... 4
1.1 Product description ................................................................................................................................................ 4
1.2 Test(s) performed/ Summary of test result ............................................................................................................ 4
1.3 Test facility ............................................................................................................................................................ 5
1.4 Measurement uncertainty ....................................................................................................................................... 5
1.5 Summary of test results.......................................................................................................................................... 6
1.6 Setup of equipment under test (EUT) .................................................................................................................... 6
1.6.1 Test configuration of EUT ............................................................................................................................. 6
1.6.2 Operating condition: ...................................................................................................................................... 6
1.6.3 Setup diagram of tested system...................................................................................................................... 7
1.7 Equipment modifications ....................................................................................................................................... 7
1.8 Deviation from the standard .................................................................................................................................. 7
2 Test procedure and test data ........................................................................................................ 8
2.1 Radiated emissions ................................................................................................................................................ 8
2.2 AC power line conducted emissions .................................................................................................................... 11
3 Test setup photographs ............................................................................................................... 13
3.1 Radiated emissions .............................................................................................................................................. 13
3.2 AC power line conducted emissions .................................................................................................................... 14
4 List of utilized test equipment / calibration .............................................................................. 15
History
Report No. Date Revisions Issued By
ERY1608P05R2 05 Aug. 2016 Initial Issue T.Kato
ERY1608P05R9 05 Aug. 2016 Replace the setup photo for Radiated emission (> 1GHz) T.Kato
Accredited by National Voluntary Laboratory Accreditation Program (NVLAP) for the emission tests
stated in the scope of the certificate under Certificate Number 200780-0
This report must not be used by the client to claim product certification, approval, or endorsement by
NVLAP, NIST, or any agency of the Federal Government.
Support Equipment
No. Item Manufacturer Model Name S/N
3 DC Power Supply YAESU MUSEN CO., LTD. FP-1030A 1412167017
4 Headphone YAESU MUSEN CO., LTD. YH-77STA YTS03
5 External Speaker YAESU MUSEN CO., LTD. SP-2000 2D060
6 Remote Control Keypad YAESU MUSEN CO., LTD. FH-2 YTS02
7 PC HP dm1-2002AU CNF027047P
8 LAN Hub NEC PA-WR8700N-HP 87N1111286973B0
Connected cable
Length
No. Cable Name From To Shielded Ferrite
[m]
A Mic. Cable 1 2 No No 0.6
B DC Cable 1 3 No No 2.8
C Phone Cable 1 4 No No 1.8
D EXT SPKR Cable 1 5 No No 1.0
E KEY Cable 1 OPEN No No 1.9
F DATA Cable 1 OPEN Yes No 1.5
G LINEAR Cable 1 OPEN Yes No 1.0
H REM Cable 1 6 Yes No 1.0
I CAT Cable 1 OPEN Yes No 2.0
J USB Cable 1 OPEN Yes No 1.4
K GND Cable 1 GND No No 2.0
L LAN Cable 7 8 No No 2.0
3: AC 120V
DC Power
60 Hz
Supply
B
5:
External 6:
Speaker Remote Control
Load Load Keypad
D H
Open E 1: I Open
F Transceiver J 7:
Open
G (EUT) K PC
Open
A C L
8: AC 120V
2: 4: LAN Hub 60 Hz
Hand
Headphone
Microphone (EUT)
Note: The signal cable E, F, G and I were connected to no AE by a request from the manufacturer.
Test procedure
Measurement procedures were implemented according to the method of ANSI C63.4 clauses 8.2.
The EUT is place on a non-conducted table which is 0.8 m height from a ground plane and the measurement
antenna to EUT distance is 3 meters. The turn table is rotated for 360 degrees to determine the maximum
emission level.
The antenna height scanned between 1 m and 4 m, and the antenna rotated to repeat the measurements for
both the horizontal and vertical antenna polarizations.
The spectrum analyzer and receiver are set to the followings;
RBW=100 kHz (up to 1000 MHz) or 1 MHz (above 1000 MHz) ,
VBW= 300 kHz (up to 1000 MHz) or 3 MHz (above 1000 MHz)
Final measurement is carried out with a receiver RBW of 120 kHz (up to 1000 MHz), or 1 MHz
(above 1000 MHz).
Calculation method
The Correction Factor and Result are calculated as followings.
Correction Factor [dB/m] = Ant. Factor [dB/m] + Loss [dB] – Gain [dB]
Result [dBµV/m] = Reading [dBµV] + Correction Factor [dB/m]
Test Data
Note: All emissions have more than 20dB margin or under noise floor.
[Chart]
[Test condition]
Test procedure
Measurement procedures were implemented according to the method of ANSI C63.4 clauses 7, clause
13.1.3 and Annex H.2 “AC power line conducted emission measurements”.
Exploratory measurements were used the spectrum analyzer to identify the frequency of the emission that has
the highest amplitude relative to the limit by operating the EUT in a range of typical modes of operation,
cable positions, and with a typical system equipment configuration and arrangement.
Final ac power line conducted emission measurements were performed based on the exploratory tests.
The EUT cable configuration and arrangement and mode of operation that produced the emission with the
highest amplitude relative to the limit are selected for the final measurement.
When the measurement value is grater than average limitation the average detection measurements were
performed.
Calculation method
The Correction Factor and Result are calculated as followings.
Test Data
[Emission level]
[Chart]
[Test condition]
AC01(EG) Anechoic Chamber (1st test room) JSE 203397C - 2016/3/26 2017/3/31
DH01 DRG Horn Antenna A.H. Systems SAS-571 785 2016/1/26 2018/1/31
PR12 Pre. Amplifier (1-26G) Agilent Technologies 8449B 3008A02513 2016/1/29 2017/1/31
The measuring equipment, which was utilized in performing the tests documented herein, has been calibrated
in accordance with the manufacturer's recommendations for utilizing calibration equipment, which is
traceable to recognized national standards.