Professional Documents
Culture Documents
3-
-1 -14-20MA -2.5 5 4-20MA 2.5
KELLER
PIEZORESISTIVE TRANSMITTERS AND TRANSDUCERS SERIES 21 R
INDUSTRIAL APPLICATIONS. ABSOLUTE AND GAUGE REFERENCES.
This new range of KELLER OEM pressure transmitters and transducers offers the user the
high accuracy and stability of the KELLER piezoresistive pressure capsule in a low cost OEM
package. Applications include refridgeration, hydraulic controls, air compressors, ink jet printers,
vacuum pumps etc.
The silicon sensor is mounted in an all welded oil filled stainless steel capsule, providing a
highly stable measuring cell with negligible hysteresis, unrivalled linearity, high output and a
life of millions of pressure cycles.
The Series 21R use the Series 6 capsule, which is of all welded 316L stainless steel construc-
tion. Transducers are supplied with 2 metres of screened cable, or a square connector and
mating plug, type mPm-193.
Accuracy is achieved by very large scale predictable production quantities of the pressure
capsule (over 2 million produced today).
Reliability is assured by the inherent properties of the perfectly elastic silicon chip, and ensuring
that neither the pressure media nor the reference media (in the gauge version) come into
contact with any sensitive parts.
Temperature Compensation: Each unit is fully tested and compensated. Span errors are
reduced by selecting the semiconductor doping levels so that the gauge factor of the strain
gauges (∆R) is constant with temperature. Thermal zero compensation is achieved by an
automatic test procedure which fits a single resistor across one arm of the bridge.
Shock and vibration performance is excellent due to the silicon chip being suspended in the
oil-filled capsule. It is isolated mechanically from the body. Similarly, the effects of mounting
torque are eliminated.
12 8 ~ 56
KELLER AG für Druckmesstechnik St. Gallerstrasse 119 CH-8404 Winterthur Tel. 052 - 235 25 25 Fax 052 - 235 25 00
KELLER Gesellschaft für druckmesstechnik mbH Schwarzwaldstrasse 17 D-79798 Jestetten Tel. 07745 - 9214 - 0 Fax 07745 - 9214 - 50
SERIES 21 R
PA 21 R 1,0 1,6 2,5 6 10 16 25 50 100 160 250 400 600 bar sealed gauge
Transmitter Transducer
Signal Output 4…20 mA 0…5 Vdc 1…6 Vdc 0…10 Vdc 0…100 mV
Supply Voltage 8…28 Vdc 13…30 Vdc 8…28 Vdc. 10 Vdc
Current required up to 20 mA 4 mA max. 2 mA max.
Zero/Span Tolerance 1% FS 1% FS** 1% FS 1% FS** ±0,1% FS
Configuration 2 wire 3 wire 4 wire
Electrical Connection: OUT/GND: Pin 1 / White GND: Pin 1 / Green GND: Pin 1 / White
mPm 193 micro or +OUT: Pin 2 / White +OUT: Pin 2 / Red
cable 2m, 4 core +Vcc: Pin 3 / Brown +Vcc: Pin 3 / Brown +Vcc: Pin 3 / Black
-OUT: Pin 4 / Blue
Linearity 0,2 % typ. / 0,5% max. 0,2% typ. / 0,5% max.
Total Error Band* 1% max. / 0,5% typ. 0,5% max.
+18…+22°C
Total Error Band* 2% max. / 1,0% typ. 1,0% max.
0…+50°C
Total Error Band* 4% max. / 2,5% typ. 2,5% max.
-20…+80°C
* Total error band includes linearity, hysteresis, zero and span offsets, temperature effects and repeatability.
**Signal at zero ≈ 50 mV --> see chart
Signal at zero for 0…5 V (0…10 V) transmitters
5V/10V
≈ 50 mV
1%FS FS
User Notes: Basic 100 mV transducers are calibrated at 10 Vdc to produce 0…100 mV signal (nominal), and require a stable voltage supply.
They can be operated at 5 Vdc to give 0…50 mV signal or 20 Vdc to give 0…200 mV signal. The circuit is a compensated resis-
tance bridge and is completely passive with no diodes or reactive components. Bridge resistance is 3,5KΩ nominal.
The 8…28 V supply transducer is fitted with an internal regulator. The mPm micro connector has a PG7 cable gland entry suitable
for cables between 4 and 6 mm diameter. Screw terminals and solder lags are provided. The G 1/4 pressure connection has an
integral Viton seal at the shoulder. Alternatively it may be sealed using a face seal on the flat nose of the pressure port.
KELLER AG für Druckmesstechnik St. Gallerstrasse 119 CH-8404 Winterthur Tel. 052 - 235 25 25 Fax 052 - 235 25 00
KELLER Gesellschaft für druckmesstechnik mbH Schwarzwaldstrasse 17 D-79798 Jestetten Tel. 07745 - 9214 - 0 Fax 07745 - 9214 - 50