Service Bulletin

0199-27-11010/0 EN
This Circular supersedes:

Date: 07.07.2011 DEUTZ AG


Author: Rudolf Fischer, VE-FI Ottostraße 1
51149 Köln

Phone: +49 (0) 221 822-3008 www.deutz.com


Fax: +49 (0) 221 822-15 3008

Changes in SerDia2000 V 1.8.4

Contents

Section Text Page


1 EMR2 security update 1
1a Normal case 2
1b The control unit is in the "DOWNLOAD mode" 3
1c The control unit is in the "NORMAL mode" but contains no data record 4
2 Password 4
3 Location of files 4
4 Security 4
5 Working structure of the hard disk 4
6 Other changes in SerDia2000 V 1.8.4 6
6a The download link for SERDIA has changed 6
6b New tasks 6
6c New trip recorder functions 9
6d Data logger 10

1. EMR2 security update

The process of the EMR2 security update has been automated, see Technical Circular
0199-27-1215.

Note:
The part numbers indicated in this document are not subject to updating.
Binding for the identification of spare parts is exclusively the spare parts documentation.
It is absolutely prohibited to multiply, publish or hand over this document - also excerpts of it.

OBJ_DOKU-26633-001.fm 1 / 10 © 2011
Service Bulletin
0199-27-11010/0 EN

a Normal case
With the interface competence level 2 and the DEUTZ service tool SERRDIA2000 Ver-
sion 1.8.4 the EMR2 software version on the control unit is read out and interpreted. If
the program has detected an update situation, the existing data record is saved on the
hard disk, the new control unit software is programmed and finally the previously saved
data record is transferred again.

Examples of a screen sequence on starting SerDia2000 V 1.8.4

OBJ_DOKU-26633-001.fm 2 / 10 © 2011
Service Bulletin
0199-27-11010/0 EN

b The control unit is in the "DOWNLOAD mode"


The control unit is in the "DOWNLOAD mode" after an error. With the interface com-
petence level 2 or higher and the DEUTZ service tool
SerDiaecuSWUpdate.exe the control unit software and the saved data record can be
programmed back.

Now start the program:


C:\Programme\DEUTZ\Serdia\SERDIA2000V1.8.4\SerDiaEcuSWUpdate.exe

OBJ_DOKU-26633-001.fm 3 / 10 © 2011
Service Bulletin
0199-27-11010/0 EN

c The control unit is in the "NORMAL mode" but contains no data record

The control unit is in the "NORMAL mode" after an error.


Case 1b now no longer works! With the interface competence level 3 plus password or
higher and the DEUTZ service tool SerDiae2000 V 1.8.4 the control unit software and
the saved data record can be programmed back.

2. Password
No password is required for the security update. Exception: see case 1c.

3. Location of files
The EMR2 security update, the software SerDia2000 V 1.8.4 and the SERDIA2000 manual
are available under the following address on the Internet: http://serdia.deutz.com/

4. Security
The communication between the control unit and SerDia2000 may not be interrupted dur-
ing programming.

5. Working structure of the hard disk


The data record of the control unit is saved on the hard disk before reprogramming.

OBJ_DOKU-26633-001.fm 4 / 10 © 2011
Service Bulletin
0199-27-11010/0 EN

The following working structure is created on the hard disk.


Example:

● C : \ D E U T Z \ S i c h e r h e i t s u p d a t e \ E M R 2 \ N e w D a t a -
Set\10272002_03112102_110303_new.hex
● C : \ D E U T Z \ S i c h e r h e i t s u p d a t e \ E M R 2 \ N e w D a t a -
Set\10272002_03112102_110303_old.hex
● The read back data records mmmmmmm_sssssss_jjmmtt_new.hex must be reported
back to the following e-mail address: emr2@deutz.com
● Nomeclature for the data records
mmmmmmmm_sssssss_jjmmtt_new.hex and
mmmmmmmm_sssssss_jjmmtt_old.hex
Example: 10748335_2124304_100913_new.hex
with yymmdd = day of the update = 100913
and sssssss and mmmmmmmm see graphic

● At the end of the programming work an adhesive label with the new part number must
be affixed to the control unit, near to the control unit or near to the diagnostic interface
for certification reasons.

OBJ_DOKU-26633-001.fm 5 / 10 © 2011
Service Bulletin
0199-27-11010/0 EN

● The appropriate part number can be found in the SerDia under DEUTZ part number.
● The adhesive labels must be ordered by e-mail from emr2@deutz.com.

6. Other changes in SerDia2000 V 1.8.4

a SerDia2000 V 1.8.4 can now only be downloaded from DEUTZ-Global-SIS.

b New tasks

Former Current
001) Set foot pedal and hand accelerator 001) Set foot pedal and hand accelerator
002) Set lower idling speed 002) Set lower idling speed
003) Set P-factor 1 003) Set P-factor 1
004) Set P-factor 2 003) Set P-factor 2
005) Set fixed speed 005) Set fixed speed
006) Set emergency speed 006) Set emergency speed
007) Pulses for vehicle speed 007) Pulses for vehicle speed
008) Set vehicle speed 008) Set vehicle speed

OBJ_DOKU-26633-001.fm 6 / 10 © 2011
Service Bulletin
0199-27-11010/0 EN

Former Current
009) Reset EEPROM error 009) Reset EEPROM error
010) CCP: CAN-Calibration-Protocol 010) CCP: CAN-Calibration-Protocol
011) Check inputs/outputs 011) Check inputs/outputs
012) Power setting 012) Power setting
014) Rapeseed oil settings 014) Rapeseed oil settings
015) Monitoring strategy
2012/2013
016) Monitoring strategy
2015
061) Logistic data

100) Motor start problem 100) Motor start problem


I I
101) Motor start problem 101) Motor start problem
II II
101a) Motor start problem
III
102) Smoke image 102) Smoke image
103) 2015: 103) Motor start problem
Motor start problem 2015
104) Power test 104) Power test
I
104a) Power test
II
105) Inspection 105) Maximum curve switching
Maximum curve switching I
(MSSCD CAN 105a) Maximum curve switching
or II
106) Check function switching [95] 106) Function switching error 95
(P-factor, maximum curve)
107) Check controller stability I II 107) Controller
I
107a) Controller
II

OBJ_DOKU-26633-001.fm 7 / 10 © 2011
Service Bulletin
0199-27-11010/0 EN

Former Current
107b) Controller
2015
108) EDC7: Main relay 108) EDC7: Main relay
109) Test "TipUp", "TipDown" 109) Speed adjustment by keys
110) Speed sensing 110) Speed sensing
I I
and and
II II
111) Water in the fuel 111) Water in the fuel
112) Pre-heating 112) Pre-heating
(flange, plug) (flange, plug)
113) CAN ERROR: 113) CAN ERROR:
125 TSC1 125 TSC1
114) CAN ERROR: 114) CAN ERROR:
106 eng prt 106 eng prt
115) Combustion noise 115) Combustion noise
116) Speed switching 116) Speed switching
117) 2015: 117) Injector error/pump error
Injector error/pump error 2015
118) Rail pressure error 118) Rail pressure error
I
118a) Rail pressure error
II
118b) Rail pressure error
III
119) EDC16: Mainrelay 1 119) EDC16: Mainrelay 1
120) EDC16: Mainrelay 2 120) EDC16: Mainrelay 2
121) Inspection 121) Engine brake
Engine brake
122) Inspection 122) Coolant level
Coolant level
122) Coolant level
2015
123) Start relay

OBJ_DOKU-26633-001.fm 8 / 10 © 2011
Service Bulletin
0199-27-11010/0 EN

Former Current
124) Reference voltage 124) Reference voltage
I
124) Reference voltage
II
125) Motor stop switch 125) Motor stop switch
125) Motor stop switch
2015
126) Speed limiting 126) Speed limiting
127) Height insert 127) Height insert
I
127a) Height insert
II
128) Volvo EMS: Urea level 128) Volvo EMS: Urea level
129) Monitoring 129) Monitoring
130) Alarm high pressure system 130) Alarm high pressure system

c New trip recorder functions


Functions (e.g. load collective) have now been activated and can be displayed conven-
iently.

There is now extra additional information about the interpretation of error images.

OBJ_DOKU-26633-001.fm 9 / 10 © 2011
Service Bulletin
0199-27-11010/0 EN

d Data logger
A data logger for measured values was installed but the data can only be displayed at
the end of the measurement. They are saved in a "CSV" format and can be read in for
example with MS-EXCEL.

Up to 15 measured values can be recorded simultaneously. There is a choice of differ-


ent measured value packages (experiments). You can also create your own measured
value packages.
Further evaluation of the data with MS-EXCEL or e.g. UNIPLOT.

If you have questions on this topic, please contact the staff member(s) below.

If you have any questions about


EMR2 security update
E-mail: emr2@deutz.com

If you have any questions about


SerDia2000 V 1.8.4
E-mail: serdia@deutz.com

This document has been created digitally and is valid without a signature.

OBJ_DOKU-26633-001.fm 10 / 10 © 2011