i JINDAL POWER LIMITED, TAMINAR RAIGARH meg | 4X 600 MW POWER PLANT ‘SOP FOR FD FAN STANDARED OPERATION PROCEDURE. FOR FD FAN [JPL/600/SOP/22] | | Issue Date: | 01.04.15 Revision No: 00 | Date: 01.04.15 NoofPages | 05 Prepared by: Lokpal Patel | Reviewed by: Naushag Hassan | Approved by: RK Choudhary, | Signature: (unr Signature: ier ® Signature: Designation: Dy. Manager Designation: Asst“General Manager | Designation: General Manager OC JPL 4x600 MW SOP Page 1 A JINDAL POWER LIMITED, TAMNAR RAIGARH Jing 4X 600 MW POWER PLANT ie fi ‘SOP FOR FD FAN in ‘Amendment Record ‘Amendment ‘Amendment Description ‘Acknowledge Rev No, | Page No. Date by Reviewer JPL4X600 MW SOP Page 2 JINDAL POWER LIMITED, TAMINAR RAIGARH | 4X 600 MW POWER PLANT ‘SOP FOR FD FAN PURPOSE: This procedure is used as work instruction for starting/stopping FD Fan. ‘SCOPE: This procedure is applicable to FD Fan located in JPL 4X600 MW. RESPONSIBILITY: Boiler Operator, Desk Engineer and Shift In charge. SPECIFICATION: GENERAL Type FAF 24.5 /11.8-1 No, OFF / BOILER 2 Medium Atmospheric Air Location Outdoor FAN DESIGN RATING Capacity (m°/s) 260 Total Head developed (mmwe) 410 Temp of medium (°C) 50 Density (ke/m?) 1.033 Speed (rpm) 390 FAN RESERVE Flow (%) 50.3 Pressure (96) 723 FAN DRIVE COUPLING . Type SPACER DRIVE MOTOR Make BHEL BHOPAL Type 11A7802-6P Rating (kW) 1425 Speed (rpm) 990 Volts (V) 3300 LUBRICATION OF EQUIPMENT Fan 25 LPM / 35 BAR FOLS (OIL. ISO - VG68) Motor GREASE LUBRICATED (SERVOGEM3) Lubrication off Servo prime 68 Oil quantity required 315 litre TYPE OF FAN REGULATION Blade Pitch Control BEARINGS Fixed bearing 7236 Free bearing NU 236 C3, LUBE OIL SYSTEM General Oil type 1S0-V6-68 Required Flow 25 LPM @ 35 Barg Oil Cooler In / Outlet temperature 60/45 °C Heat exchanged capacity 3250 Keal/h Filter mesh rating / Material 25 microns / SS 304 Suction strainer mesh rating / 149 microns / Stainless Stee! JPL 4X60 MW SOP Page 3 4) 5) 9) 1) 2) 3) ] JINDAL POWER LIMITED, TAMAR RAIGARH rT a 4X 600 MW POWER PLANT [ere | SOP FOR FD FAN Utilities Motor type & Rating TEFC & 3.7 kW, 1440 rpm, 415 V, 50 Hz, 3 Phase, [P55 Materials of Construction Tank capacity / Material 350 liters / IS 2062 Pipe / Fittings Material A106 Gr. B PROCEDURE: : LINE UP PROCEDURE: 1) No PTWis pending 2) All manholes in secondary air duct are closed. 3) Ensure FD Fan breaker is normalized and is in Remote condition, DMCW (SG) pump is in service. Line-up cooling water to Lube oil cooler ( DMCW Supply, return valves are open ) 6) Fan Outlet gate is closed. 7) Lube oil level is normal. 8) All instruments are lined up. Ensure Air heater is lined up. 10) Ensure APH & 1D Fan is running. 11) Motor protection relay is healthy. 12) Ensure EPB is released. 13) Both lube oil pumps modules are ON and inremote. * 14) Fan discharge damper module is ON and in remote. ‘START UP: Start lube oll pump. Ensure lube oil pressure is normal (>4 kg/cm’) and control oil pressure normal (>10 kg/cm’). Keep the Blade pitch is in minimum position. Ensure all FD fans start permissive are healthy, 4) Start the FD fan and Ensure lischarge gate is full open in Auto. 5) Ensure furnace pressure is within the permissible range. 6) Ensure bearing vibrations and bearing temp are within the permissible range. SHUTDOWN: 1) Reduce the unit load less than 50% if first FD fan is stopping. 2) Unload the fan by reducing the blade pitch to min. 3) Stop the fan. x 4) Close discharge gate. ISOLATION PROCEDURE: 1) Ensure fan is OFF. | 2) Isolate DC supply and rack out the break JPL4X600 MW SOP Page 4 | JINDAL POWER LIMITED, TAMNAR RAIGARH smog 4X 600 MW POWER PLANT ‘SOP FOR FD FAN 3) Isolate discharge gate module. 4) Isolate Lube oil pumps (A, B) modules. (After lube oil system was stopped.) |CROSS REFERENCE: FD Fan Manual RECORDS: The records are maintained in field Engineer log book and in CCR log book. —————_—_ JPL 4X60 MW SOP Page 5

You might also like