JINDAL POWER LIMITED, TAMNAR RAIGARH 4X 600 MW POWER PLANT SOP FOR AIR PRE-HEATER STANDARED OPERATION PROCEDURE FOR AIR PRE-HEATER [JPL/600/SOP/17] Issue Date: | 01.04.15 Revision No: 00 Date: | 01.04.15 | No of Pages 06 Prepared by: Lokpal Patel Signature: Cpe. Reviewed by‘ Ravindra Sonkusare _| Approved by: .R K Choudhai Spat OGIO Tl soon Bees are Designation: Dy. Manager Designation: Asst. General Manager | Designation: General Manager JPL4Xx600 MW SOP Page 1 ] JINDAL POWER LIMITED, TAMNAR RAIGARH 4X 600 MW POWER PLANT SOP FOR AIR PRE-HEATER Amendment Record ‘Acknowledge ‘Amendment | Amendmen Description by Reviewer RevNo. | Page No. | t Pate 1 a Page 2 JPL4X600 MW SOP ] JINDAL POWER LIMITED, TAMINAR RAIGARH ] nog 4X 600 MW POWER PLANT SOP FOR AIR PRE-HEATER | PURPOSE: This procedure is used as work instruction of Starting/Stopping of Air Pre-Heater. ‘SCOPE: This procedure is applicable to Air Pre-Heater located in JPL 4X60 MW. RESPONSIBILITY: Boiler operator, Desk Engineer ,Unit control engineer& Shift In charge. SPECIFICATION OF AIR PRE-HEATE! GENERAL No. per boiler / size 2.Nos. / 32.5 VIMT 2000 (72" PA) HEATING ELEMENTS Hot end heating elements Element type 0.8 mm ~ DU profile Element height 850mm Material Carbon steel Hot int, heating elements Element type 0.8 mm —DU profile | Element height 850 mm Material Carbon steel | Cold end heating elements | Element type 1.2 mm —NF6 profile Element height 300 mm Materi Corten steel ROTOR SEALS Radial seals — Hot End 2.5 mm Corten A Radial seals ~ Cold end 2.5 mm Corten A Axial seals 2.5 mm Corten A Bypass seals 1.6 mm Corten A Rotor post seals HE & CE 6.0 mm IS 2062 ROTOR DRIVE ASSEMBLY Motor 30 KW, 1500 rpm, 415 V, 3 phase, 50 He, Frame: 200 L Speed Reducer Type 8APB, 3 input, down shaft ( M/s shanti Gears Itd Fluid Coupling 14.5 FCU-Pembril / Fluiodomat AUXILIARY DRIVE Air motor M/s IEC Dusterloh Coupling M/s Bibby Coupling type R24H Solenoid Valve 230 V, 1 Phase, AC, 50 Hz~1” BSP Pressure Switch 4% NPT (F), 0-10 ke/em2 Filter & Lubricator "BSP BEARINGS | Guide Bearing Spherical Roller 23192 / CAK/ C3/ W33 Taper Bore Support Bearing Spherical Roller Thrust 294/850 EF RTD 1” BSP (M) Duplex Thermo well OIL CIRCULATION SYSTEM. nn JPL 4X600 MW SOP Page 3 Jog JINDAL POWER LIMITED, TAMNNAR RAIGARH 4X 600 MW POWER PLANT Motor ~ Guide & Support Brg. Pump Filter Cooler Coupling Pr. Gauge with needle valve Flow switch Dial thermometer with well CLEANING DEVICE ASSY ~ LRNR Motor Nozzle travel & traverse speed Steam pr, qty & blowing rate Operating time ~ Forward + Return Nozzles size Blowing FIRE SENSING DEVICE Location Make SERVICE WATER CONSUMPTION Water washing ~ hot end Water washing ~ cold end Deluge assy — hot end Deluge assy ~cold end STEAM COIL AIR PREHEATER Number of SCAPH Size of SCAPH Installed Position Design Pressure Design temperature Hydraulic Test pressure Weight of one SCAPH Supplier SET POINTS Lub Oil systems (Guide & Support Brgs) Oil Flow Switch Relief valve set pressure RTD ~Start temperature of LOS RTD ~Alarm temperature Main drive assy ~ Air line components Pressure switch ~ Before solenoid valve Pressure switch ~ After solenoid valve Fire sensing device Alarm temperature SEAL SETTING VALUES Radial seals ~ Hot end inboard JPL 4X600 MW SOP ‘SOP FOR AIR PRE-HEATER 0.75 kW, 3 ph, 1500 rpm, fr. 90S Tushaco~ Delta, model: T35-25 / 46 John Fowler / HP Values ~ 15 LPM M/s united Heat transfer / Nasik Love joy L095 M20 x 1.5; 0-10 kg/em2 Universal Flow monitors %" BSP, O- 100 oC 0.25 kW, 3 phase, 415 V, 50 Hz 11860 mm & 90 mm / min 14 kg/cm’, 1135 kg & 54.94 ke/min 20.67 min + 20.67 min 12.5 mm (1 no.) & 16 mm (2 nos.) Forward traverse only Thermocouple ~ 12 + 12 point T/C Gas outlet & Air outlet M/s Pyrotech Electronic/ Udaipur 300 cum / hr / pipe 300 cum / hr / pipe 300 cum / hr / pipe 300 cum / hr / pipe 2'/ boiler 6000x3900x350 Horizontal 16 kg/cm? 210°C 30 kg/cm? 3650 kg/unit M/s Patel Air Temp Pvt Ltd. 7LPM 5S kg/cm? 40°C 70°C 5 kg/cm? (g) 3 kg/cm? (g) 450°C 0.50 mm. Page 4, JPL4X600 MW SOP (| | JINDAL POWER LIMITED, TAMNAR RAIGARH smog 4X 600 MW POWER PLANT | ‘SOP FOR AIR PRE-HEATER | Hot end outboard 0.50 mm Cold end inboard 0.50 mm Cold end out board 29.5 mm Axial seals Hot end 124mm Cold end 7.1mm By pass Seals ~ Hot end 6.6mm Cold end 19mm INDUCTION MOTOR Make KIRLOSKER ELECTRIC CO. LTD Power 30KW Speed 1470 Volts 41sv Current 52 Amps | AIR MoToR Make IEC DUSTERLOH PVT LTD. Power 6.8KW | RPM 3000 rpm Air Pressure 6.33 ke/em2 Ratio 08:01:00 Output RPM 375 RPM LUBE OIL SYSTEM MOTOR Make NGEF Volts 415V Current 70 Amps | RPM 1400 KW 0.75 Pump Make TUSHAKO PUMP PVT LTD. Capacity 15LPM Pressure 5 KG/CM2 PROCEDURE: LINE UP PROCEDURE : 1) NoPTWis pending 2) AILAPH manholes are closed. 3) APH fire water MIVs are closed. 4) APH wash water MIVs are closed. 5) APH MOTOR module is ON and in remote. | 6) GB, SB lube oil pumps (A, B) modules are ON and in remote. 7) At least one DMICW SG pump Is in service. | 8) Atleast one Service air compressor should be running and air'pressure adequate. 9) Line-up cooling water to lube oil coolers. (DMCW supply and return MIVs are open ) 10) Open lube oil pump suction valve, cooler outlet valve. Page S JINDAL POWER LIMITED, TAMNAR RAIGARH snag 4X 600 MW POWER PLANT ‘SOP FOR AIR PRE-HEATER 11) DMCW |/L and O/L MIVs for oil carry over probe should open’ 12) Open air isolation MIV for air motor and ensure air pressure low switch is in reset condition. | STARTUP: 1) Start Guide Bearing lube oil pump (Starts in AUTO at 40'c). 2) Start Support Bearing lube oil pump (Starts in AUTO at 40'c). 3) Start Air Motor and check AIR inlet solenoid valve opens in Auto. 4) Start APH Motor and observe that Air Motor Stops in Auto. ‘SHUT DOWN: 1) Flue gas temperature at APH inlet should be less than 90°C 2) Stop APH Motor. 3) Ensure Support Bearing lube oil pumps Stops when bearing temperature is below 38c. 4) Ensure Guide Bearing lube oll pumps stops when bearing temperature is below 38c. ISOLATION PROCEDURE: 1) Close air motor air supply manual isolation valves ( Solenoid inlet, outlet , bypass ) 2) Isolate the APH motor module. 3)_ Isolate Guide Bearing lube oil pumps (A, B) modules. 4)_ Isolate Support Bearing lube oil pumps (A, B) modules. (CROSS REFERENCE: Air Pre-Heater Manual. RECORDS: The records are maintained in field log book and in CCR log book JPL 4x60 MW SOP Page 6

You might also like