Catalogue Chiller CGAP.H
Catalogue Chiller CGAP.H
Application Consideration 6
Mechanical Specification 8
Selection Procedures 12
Dimensional Drawing 13
Wiring Diagram 16
2
Standard Product
Model Nomenclature
C G A P 0 2 5 D 1 H X A 0 0 A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
DIGIT 1,2,3 Chiller / Cooling Only / Air-Cooled DIGIT 11 Factory Installed Options
X = None
DIGIT 4 Development Sequence 1 = Corrosion Resistant Coated Fin
C G A H 0 8 0 D E X 1 R A N A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
DIGIT 1,2,3 Chiller / Cooling Only / Air-Cooled DIGIT 11 Factory Mounted Control
1 = DOL Starter with CAREL Controller
3
CGAP - CGAH
General Data
CGAP 025 CGAP 030 CGAP 040 CGAP 050 CGAP 060 CGAH 080
Performances (1)
Gross Cooling Capacity [R22] (1) (kW) / (MBH) 6.45 / 220.3 77.7 / 265.2 100.1 / 341.8 127.1 / 433.8 156.1 / 532.8 208 / 710
Gross Cooling Capacity (R407C) (kW) / (MBH) 61.3 / 209.3 73.8 / 252 95 / 324.7 120.7 / 412 148.8 / 506.2 197 / 674
Unit Capacity Steps (%) 100-50 100-50 100-75-50-25 100-75-50-25 100-75-50-25 100-75-50-25
Total Compressor Power Input (1) (kW) 25.2 26.8 36.2 50.4 53.6 75.2
Main Power Supply 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50
Utilization Range 400 +, - 10%
Sound Power Level (dB(A) 87 89 89 90 92 92
Compressor
Number 2 2 4 4 4 4
Type Scroll Scroll Scroll Scroll Scroll Scroll
Model 2x13T 2x15T 2x(10T+10T) 2x(13T+13T) 2x(15T+15T) 2x(20Tx2)
Speeds Number 1 1 1 1 1 1
Motors Number 1 1 1 1 1 1
Unit MCA Amps (3) (A) 49 57 75 93 108 147
RLA / LRA (2) (A) 20.5 / 135 24 / 175 16.5 / 130 20.5 / 135 24 / 175 31 / 215
Motor RPM (rpm) 2900 2900 2900 2900 2900 2900
Condenser Coil
Type Plate Fin Plate Fin Plate Fin Plate Fin Plate Fin Plate Fin
Tube Size (mm) 9.52 9.52 9.52 9.52 9.52 9.52
Tube Type Smooth Smooth Smooth Smooth Smooth Smooth
Height (mm) 1860 1860 1860 1860 1860 1579
Length (mm) 1782 1782 1782 1782 1782 2740
Quantity (mm) 1 1 2 2 2 2
Face Area (m2) 3.33 3.33 6.66 6.66 6.66 8.7
Rows 2+3 3 2 2+3 3 3
Fins Per Inch (fpf) 144 144 144 144 144 144
Evaporator Data
Type <--------- Brazed Plate Heat Exchanger --------->
Water Flowrate US GPM 45 54 70.0 88 108.5 142
Nominal Flow, water PD ft H2O 7.4 7.5 8 6.3 8.6 37
Minimum Flowrate US GPM 33.8 40.5 52.5 66 81.4 106.5
Maximum Flowrate US GPM 56.3 67.5 87.5 110 135.6 177.5
Water Strainer Standard, Accessory, Ship with but installed at site
Water Connection BSPT 2 1/2” 2 1/2” 2 1/2” 2 1/2” 2 1/2” 2 1/2”
Fan
Type Propeller Propeller Propeller Propeller Propeller Propeller
Number 2 2 3 4 4 6
Diameter (mm) / (in) 711 / 28 711 / 28 711 / 28 711 / 28 711 / 28 760 / 30
Drive Type Direct Direct Direct Direct Direct Direct
Speeds Number 1 1 1 1 1 1
Motors Quantity 2 2 3 4 4 6
Motors kW (2) kW / hp 0.6 / 0.75 0.6 / 0.75 0.6 / 0.75 0.6 / 0.75 0.6 / 0.75 0.9 / 1.2
FLA(2) (A) 1.5 1.5 1.5 1.5 1.5 2.5
Motor RPM (rpm) 900 900 900 900 900 720
Dimensions
Height (mm) 1911 1911 1911 1911 1911 2002
Width (mm) 1002 1002 1992 1992 1992 1950
Length (mm) 2264 2264 2264 2264 2264 3160
Weight Uncrated (kg) 583 593 990 1153 1177 2030
Weight Crated (kg) 603 613 1025 1188 1212 2080
System Data
Refrigerant Circuit 1 1 2 2 2 2
Minimum Outdoor Air Temperature for Mechanical Cooling
Standard Ambient Operating Range (F) 59-109 F 59-100 F 59-109 F 59-109F 59-109F 59-109F
(C) 15-43 C 15-43 C 15-43C 15-43 C 15-43 C 15-43 C
High Pressure [cut out -cut in] (psig) 415 ± 10 psig, 250 ± 15 psig
Low Pressure [cut out - cut in] (psig) 45 ± 5 psig, 60 ± 5 psig
Notes
[1] Based on chilled water EWT 7 LWT of 54 deg. F & 44 deg F and 95 deg [3] Minimum Circuit Ampacity (MCA) is 125% of the largest compressor RLA plus 100%
[2] Per Motor @ 400V of the other compressor RLA plus the sum of the condenser fan FLA.
4
Standard and Optional Features
CGAP - CGAH Air-Cooler Chillers
Features Installation
All chillers are completely factor-wired
with necessary capacity and safety
Reliability controls, enclosed in a weather - tight
The compressors used are proven control panel with knockouts for
world class hermetically sealed scroll jobsites installed wiring. This ensures
compressors. These scroll compres- smooth and trouble-free installation.
sors are among the industries most Units arrives at jobsites fully as-
resilient and efficient compressors. sembled, tested, charged and ready to
provide chilled water. No messy field
assembly or refrigerant charging is re-
quired. Further, the unit has been de-
signed for a single power and water
connection.
Optional Features
Corrosion-resistant finned con-
denser coil
A layer of resin is coated on to the sur-
face of the fins to increase resistance
to corrosion in harsh environmental
conditions. A 500 hour, salt-spray test
(in accordance to JIS-Z-2371) and hu-
midity test (at 50 deg. C, 98% relative
Brazed Plate Heat Exchanger With humidity) had been performed to con-
Intergrated Distributor firm the corrosion-proof property of this
With brazed corrugated stainless steel coating.
plates, this compact heat exchanger
offers a highly efficient heat transfer Full Packaged Controls
rate that is less susceptible to erosion All units come fully packaged with fac-
and corrosion while maintaining a ho- tory engineered starters and electronic
mogeneous distribution of refrigerant. controls that give full diagnostic and re-
mote alarms. Integration with Trane
Serviceability tracer summit BMS is available
The control and unit panels are com- through LONTALK.
pletely removable for service accessi-
bility and convenience. “Rapid access” Footprint
clips and Allen key arrangements allow Central to the design of any project is
fast access to the major components the operating envelope of the air-
in the units. cooled packaged chiller. Trane CGAP
air-cooled chillers have compact foot-
prints to make the most efficient use of
the available installation space. Their
modular designs allows max installer
space savings on multi unit installa-
tions.
Flow Switch
Central Factory installed standard that
indicates loss of flow, to prevent dam-
age caused by freezing.
5
Application Consideration
6
Application Consideration
Anti-recycle Timer sales engineer if your application re- changes can be accommodated. A typi-
All CGAP/H air-cooled chillers come quires varying flows. cal piping arrangement is shown be-
with anti-recycle timer the function of low in Figure 1.
which is to prevent rapid cycling of the Temperature Limits
compressors due to low load condi- The maximum catalog leaving water Short Water Loops
tions or short water loops. temperature is 540F (120C). High leaving The proper location of the temperature
water temperature exceeding this may control sensor is in the leaving water
Loss Of Flow Protection result in excessive suction temperatures for CGAP/H’s. This location allows the
Full chilled water flow must be main- and therefore inadequate compressor building to act as a buffer and help sta-
tained through the evaporator while motor cooling. For temperatures below bilize the return water temperatures. A
compressors are operating. Loss of a 50C (410F), please consult your local short water loop (less than one minute
flow may result in evaporator freeze-up. Trane respresentive. in duration) will lead to erratic system
Though CGAP/H’s have a loss of flow operation. To prevent the effect of a
protection, a flow switch is added as a Supply Water Temperature Drop short water loop the following items
safety inter-lock for all the CGAP/H The performance data for Trane CGAP/H should be given careful consideration:
models. air-cooled chillers is based on a chilled
water temperature drop of 100F 1 Add storage tank to increase the vol
Water Flow Limits (50C).Chilled water temperature drops ume of water in the system andthere
The minimum and maximum water from 8 to 120F may be used as long as fore reduce the rate of change of the
flow rates are given in the “General minimum and maximum water tem- return water temperature.
Data” section of this catalog (page 4). perature and minimum and maximum
Evaporator flow rates below the tabu- water flow rates are not violated. 2 Use three-way modulating valves in
lated values will result in laminar flow lieu of two-position valves withcross-
causing scaling, stratification, freeze- Typical Water Piping over pipes at the airside evaporators.
up problems and poor temperature All building water piping must be The three-way valves will reduce the
control. Flow rates exceeding the maxi- flushed prior to making final connections rate of change in the return water
mum tabulated values will results in to the chiller. To reduce heat loss and temperature.
very high pressure drop. Trane recom- prevent condensation, insulation are to
mends that constant water flow be be applied. Expansion tanks are usually
maintained at all times through the required so that chilled water volume
evaporator. Consult your local Trane
7
Mechanical Specification
8
CGAP Performance Data (IP Units)
Notes:
1. Ratings based on ARI Standard 590-92.
2. Data based on evap. temperature drop of 10deg.F.
3. Ratings are also applicable for evaporator temperature drop of 8 to 12 deg.F.
4. Interpolation between points is permissible extrapolation beyond points is not allowed.
5. Kw input is for compressor only.
9
CGAP Performance Data (SI Units)
Notes:
1. Ratings based on ARI Standard 590-92.
2. Data based on evap. temperature drop of 10deg.F.
3. Ratings are also applicable for evaporator temperature drop of 8 to 12 deg.F.
4. Interpolation between points is permissible extrapolation beyond points is not allowed.
5. Kw input is for compressor only.
10
Performance Data (CGAH)
ambient temperature
leaving water 25 30 35 40
temperature (c) cooling Input cooling Input cooling Input cooling Input
capacity (kW) power (kW) capacity (kW) power (kW) capacity (kW) power (kW) capacity (kW) power (kW)
5 217.9 59.2 208.4 65.7 198.2 73.2 187.5 81.4
7 228.5 59.9 218.5 66.5 208.0 76.9 196.9 82.4
9 238.8 60.7 228.5 67.3 217.7 75.0 206.1 83.4
Note: Correction factor should be considered when ethylene glycol is used in the chilled water system. (actual value = original value x correction
factor)
11
Selection Procedures
12
Dimensional Drawing
CGAP 025, 030
13
Dimensional Drawing
CGAP 040, 050, 060
14
Dimensional Data Air Cooled
Chiller Unit CGAH 080
15
Wiring Diagram
CGAP 025/030 Power DOL
Starter c/w Carel Controller
16
Wiring Diagram
CGAP 025/030 Power DOL
Starter c/w Carel Controller
17
Wiring Diagram
CGAP 040/050/060 Power DOL
Starter c/w Carel Controller
18
Wiring Diagram
CGAP 040/050/060 Power DOL
Starter c/w Carel Controller
19
Wiring Diagram
CGAH 080 Power DOL
Starter c/w Carel Controller
20
Wiring Diagram
CGAH 080 Power DOL
Starter c/w Carel Controller
21
Standard Conversion Table
22
Standard Conversion Table
23
Literature Order Number CG-PRC016-E4 (September 2010)
File Number
Trane Supersedes CG-PRC016-E4 (September 2008)
Stocking Location Malaysia
www.trane.com