You are on page 1of 1

LEGENDS:

GV : GATE VALVE
GBV : GLOBE VALVE
BV : BALL VALVE
MD : MANUAL DAMPER
KEL CLIENT FB : FLEXIBLE BELLOW
EA-150-CS-104-50-HI
PG PG ST : STEAM TRAP
104 105 TO STACK
N2 S : STRAINER
BV-105

BV-106
15NB

15NB
EA-200-SS-102-50-HI
BFV : BUTTERFLY VALVE
EA-200-SS-103-50-HI VE-25-CS-101-0
TG : TEMPERATURE GAUGE
FB-103 N8
PG : PRESSURE GAUGE
HI MD-102 FB-102 HI
M I LG : LEVEL GAUGE
103 005 KEL CLIENT TCV : TEMPERATURE CONTROL VALVE
ID-101 40NB
SW-40-CS-103a-0 TE : TEMPERATURE ELEMENT
15NB
DPG I TIC : TEMPERATURE INDICTOR CONTROLLER
101 003 BV-114 40x25 N3 N1 MAKE UP LS : LEVEL SWITCH
BV-104 VS-101 WATER
XV-101
BV-103
15NB

40NB MOTOR:
N2 SW-40-CS-103b-0
50NB M-101: MOTOR FOR PADDLE DRYER
CLEANING HI
NOZZLE BV-113 N4a/b TW-25-CS-101-0 M-102: MOTOR FOR FORCED DRAFT FAN
N7
N1 M-103: MOTOR FOR INDUCED DRAFT FAN
HI
M-104: MOTOR FOR SCRUBBER PUMP
N5
N4 M-105: MOTOR FOR FEEDER
EA-200-SS-101-50-HI

CY-101 PG SW-40-CS-105-0 N6
M-106: MOTOR FOR ROTARY VALVE
106 N10

BV-112
25NB
N3
BV-111
N1 N5

15NB
MEDIUM
N6a

SW-40-CS-104-0
I SA : SCAVENGING AIR
005 40NB
BV-108 EA : EXHAUST AIR
TG N8
103 ST-101 N7 LS LPS : HIGH PRESSURE STEAM
HI N3 SW-40-CS-102-0 MH
101 LG CO : CONDENSATE
RAV-101 L 101
M TO DRAIN 40NB
SW : SCRUBBER WATER
106 KEL 50NB N2 N6b TW : MAKE UP WATER
METERED FEED SLUDGE N9 VA : VENT AIR
CLIENT BV-107 KEL
(WET CAKE) SW-50-CS-101-0
I M BV-110
FEED RATE-500 kg/hr, 005 40NB CLIENT MOC:
MOISTURE-80%W/W PG
FINES 104
SA-80-CS-103-50-HI

BV-109 KEL SS SS-316


103 SP-101
CLIENT CS CARBON STEEL
BV-102
15NB

TO DRAIN INTER LOCK :


I 001: IF PADDLE DRYER DRIVE (M-101) TRIPPED, STOP THE
TG PG
N3 102 102 EQUIPMENT IN FOLLOWING SEQUENCE:
HI CLIENT HI TO DRAIN
BV-115

SA-150-CS-101-50-HI 1) SIGNAL TO BE SENT TO STOP FEEDING MATERIAL.


BV-101

N5
80NB

KEL
15NB

CLIENT KEL N1a N1b N11a N12 N3 N11b N5 2) STOP STEAM FLOW TO DRYER BY CLOSING TCV-101.
N1
N2 SA-150-CS-102-50-HI
FB-101 BFV-102 N6 I 002: IF FORCED DRAFT FAN DRIVE (M-102) TRIPPED THEN
MD-101 TI TI
M N6
101 102 1) SIGNAL TO BE SENT TO STOP FEEDING MATERIAL.
BN-101 AH-101
102 N4 2) STOP STEAM FLOW TO DRYER BY CLOSING TCV-101 WITH A TIME
FD-101 HI SHAFT 2 SHAFT 1
KEL
DELAY.
I
I 002 TE TE TE 3) STOP DRYER (M-101).
003 CLIENT
101 102 103
C0-25-CS-109-50-HI

I M
I 001 101 N4a N4b N4c
005
PADDLE DRYER (101)
I 003: IF INDUCED DRAFT FAN DRIVE (M-103) TRIPPED THEN STOP THE
VENT EQUIPMENT IN FOLLOWING SEQUENCE:
N2

N10a
N10b
1) SIGNAL TO BE SENT TO STOP FEEDING MATERIAL.

N9b
I I

N9a
KEL

25NB

25NB
15NB 002 003 KEL KEL
25NB

GV-106 CLIENT KEL 2) STOP FORCED DRAFT FAN (M-102).


25NB

GV-108 ST-102 S-102 GV-107 CLIENT CLIENT

N13
I I 3) STOP STEAM FLOW TO DRYER BY CLOSING TCV-101.
N8a

N8b

N7a
CLIENT
005 004

LPS-40-CS-104-50-HI
N7b

LPS-40-CS-103-50-HI

CO-25-CS-105-50-HI
CO-25-CS-106-50-HI
LPS-25-CS-108-50-HI

H HI 4) STOP DRYER (M-101).


25NB 25NB
HI TIC DRY PRODUCT : 110 kg/hr
GBV-105 103 L @ 10% W/W I 004: IF FEEDING STOPPED / TRIPPED THEN STOP THE
25NB MOISTURE CONTENT EQUIPMENT IN FOLLOWING SEQUENCE:
GBV-103

GBV-104

CO-25-CS-101-50-HI

CO-25-CS-102-50-HI
25NB

25NB
TEMP. : 105°C 1) STOP STEAM FLOW TO DRYER BY CLOSING TCV-101 WITH A TIME DELAY.
2) STOP DRYER (M-101).

LPS-25-CS-107-50-HI
LPS-25-CS-106-50-HI
TO DRAIN
I 005: IF SCRUBBER CIRCULATION PUMP (M-104) TRIPPED THEN STOP THE
EQUIPMENT IN FOLLOWING SEQUENCE:
1) SIGNAL TO BE SENT TO STOP FEEDING MATERIAL.
2) STOP STEAM FLOW TO DRYER BY CLOSING TCV-101.

GBV-102
GBV-106

50NB
3) STOP DRYER (M-101).
25NB

CO-40-CS-103-50-HI 4) STOP FORCES DRAFT FAN (M-102)

LPS-40-CS-105-50-HI
5) STOP INDUCED DRAFT FAN (M-103).

LPS-50-CS-102-50-HI
6) STOP RAV (M-106).
I I
005 004 LINE TAG SPECIFICATION :
PG I I I
101 003 002 001
TG
101
TCV
GV-103

101 INSULATION TYPE


GV-101 15NB
GV-104 GV-105 INSULATION THICKNESS
STEAM @ 7 bar(g),
580 kg/hr, 169°C LINE NO
80NB 80NB FC 80NB
LPS-80-CS-101-50-HI
MATERIAL
GV-102

GBV-101
15NB
80NB LINE SIZE
DRAIN
MEDIUM CODE
CO-40-CS-107-50-HI
HI GV-109 S-101 ST-101 GV-110
CO-25-CS-108-50-HI
CONDENSATE RETURN
25NB 25NB
GBV-107
25NB
PADDLE DRYER BIRD NET AIR HEATER FORCED DRAFT FAN CYCLONE ROTARY VALVE (BELOW CYCLONE) INDUCED DRAFT FAN VENTURI SCRUBBER SCRUBBER TANK SCRUBBER PUMP
TAG NO : PD-101 TAG NO : BN-101 TAG NO: AH-101 TAG NO : FD-101 TAG NO : CY-101 TAG NO : RAV-101 TAG NO : ID-101 TAG NO : VS-101 TAG NO : ST-101 TAG NO : SP-101
QTY : 1 QTY : 1 QTY : 1 QTY : 1 QTY : 1 QTY : 1 QTY : 1 QTY : 1 QTY : 1 QTY : 1
NOTE:
1. STEAM CONTROL VALVE, STEAM & CONDENSATE SUPPLY AND
RETURN LINE PIPING, ALL INSTRUMENTS & MANUAL VALVES
SHOWN AS IN CLIENT SCOPE OF SUPPLY

You might also like