The press models PP13, PP10 and PP10 Universal are equipped with conveyor
sensors type Pepperl and Fuchs, item number 711.911/8.
These afore-mentioned conveyor sensors are superseded by the new type conveyor
sensors with synchronization type Pepperl & Fuchs, item number 844.148/7.
For a change-over to synchronized sensors the assembly set 844.261/8 is needed and
the sensors located in the middle and at the end of the conveyor are to be replaced.
Also the sensor cables of transmitters are to be replaced when making the change-over
as per wiring diagram of this assembly set.
The item numbers always stand for 2 sensors, one transmitter and one receiver, which
are packed together in one box. Both the sensors, transmitter and receiver have been
fine-tuned by the manufacturer to match one to the other and thus must only be
installed in pairs. To avoid possible faults readings, do never mix up with sensors of
different boxes.
Moreover, mind not to install 2 transmitters or 2 receivers on one guiding plate. To avoid
mistakes the plug allocation for transmitters and receivers are different.
Illustration of alternating fitting of transmitter and receiver to guide plate, for example
right hand side, discharge direction:
transmitter receiver
B11.1 B12.2
Illustration of alternating fitting of transmitter and receiver to guide plate, for example left
hand side, discharge direction:
transmitter receiver
B11.2 B12.1