Micro channel heat exchanger Rev, Seq: D1
PRF
(condenser) Date: 2016-12-16
Checking Directive
BSH
1 General information
This document specified only the part specified requirements for Microchannel heat exchanger
(condenser) applied in BSH product area “Refrigeration”.
All general requirements specified in BSH checking directive “General requirements for parts
and components in cooling circuits” 1 must be met, too.
All national and international standards and references given in Chapter 3 (in case of any) must
be considered. Suppliers must commit that they are familiar with content of these standards and
producing, testing accordingly.
This test is intended to confirm the suitability of component for operation and storage in
environment of high relative humidity combined with periodical changes of temperature, where
condensation on component circle occurs.
After the test corrosion or obviously visible oxidation of the component surfaces are not
acceptable.
Material applied during manufacturing and assembly, which might have contact with refrigerant
carrying part, must be approved by manufacturer for their compatibility with the refrigerant carry
part. They are not allowed to cause corrosion. Once BSH requires, supplier must deliver BSH
the approval. They are not allowed to leave any abrasion or other residues, which can cause
corrosion, neither.
Manufacturers must pay attention to following points during manufacture to prevent corrosion:
All machines, conveying systems and other tools must be made out of abrasion resistant
materials in order to avoid the possibility of unwanted materials to get onto the surface of
the parts
All substances and materials used in production and handling (coolants, lubricants,
cleaning agents, etc.) must be free of corrosive substances such as chloride, graphite,
sulfate, phosphate, sulphur, etc.
1
Checking directive: 57000000139061 Requirements for cooling circuit
2
Checking directive: 57000000136652 Climatic tests Tropical environment
BSH Hausgeräte GmbH Page: 2 Creation Date: 2016-12-16