OMC Oil Controls

The OMC maintains a proper oil level in the compressor crankcase


and is available for high voltage applications for various refrigerants.
It is ideal for use with Copeland Scroll™ compressors as well as all
brands of semi-hermetic compressors.
Features
• Prevents compressor burnout and system downtime
• Five time compressor lockout feature alerts repeated low oil for
early system diagnosis and resolution
• Self-contained unit with oil level sensor and integral solenoid to
manage oil level supply
• Multiple voltage ratings eliminate need for stepdown transformer
• Adapters available for various compressor types(not required for
reciprocating compressors) Specifications
• Optional side sight glass provides oil level viewing from multiple OMC OMC NH3 OMC CO2

directions Maximum Working Pressure (MWP) 870 psig 1885 psig


Solenoid min/max OPD 0/350 psig 0/1450 psig
• Oil level float ball in sight glass allows quick visual indication
120V or 220-240V, 24, 120V or 220-240V,
• Easy monitoring with visual alarm and multi-color LED status Supply Voltage
50/60 Hz 50/60 Hz
lights Solenoid Coil EMF

• SPDT output contact for compressor shut-down and alarming 0.15 Amp (120V), 0.6 Amp (24V) 0.15 Amp
Current Consumption 0.07 Amp (120V), 0.07 Amp
• System debris retention magnet for reliable operation (220-240V) (220-240V)
• Hall-effect sensing technology unlike optical sensors, eliminates Time Delay for Low Level Signal 10 seconds

false detection of possible oil foaming Time Delay After Setpoint Recovery 5 seconds

• Approved oil management control for Copeland Scroll Alarm Delay Time
(Including Alarm Contact)
120 seconds
Compressors Alarm Switch SPDT
10A @ 120VAC 50/60 Hz, 5A @ 250VAC 50/60 Hz,
Alarm Contact Rating
3A @ 30VDC
Nomenclature Example: OMC D120CO2 Class A1
OMC D 120 CO2 Refrigerant Compatibility (incl. subcritical Ammonia Transcritical CO2
CO2)
Series Configuration Coil Voltage Application
Refrigerant Temperature -40° to 180°F Maximum
CO2 - Transcritical CO2
S - Single Sight Glass 120 - 120V 50/60 Hz Ambient Temperature - Storage -40° to 120°F Maximum
OMC NH3 - Ammonia
D - Dual Sight Glass 240 - 220-240V 50/60 Hz Ambient Temperature
(Omit For Standard) -40° to 120°F Maximum
- Intermittent Duty
1/4” Male SAE
Oil Supply Fitting (Stainless
Ordering Information (Brass)
Steel)
(Brass)

Model Description PCN


OMC S120 Single (front) sight glass with solenoid coil 120V 50/60 Hz 066823
OMC S240 Single (front) sight glass with solenoid coil 220-240V 50/60 Hz 066824 Dimensional Data
OMC D120 Dual (front & side) sight glass with solenoid coil 120V 50/60 Hz 066817
OMC D240 Dual (front & side) sight glass with solenoid coil 220-240V 50/60 Hz 066818
OMC D24CO2 Dual (front & side) sight glass with solenoid coil 24V 50/60 Hz for transcritical CO2 066991
OMC D120CO2 Dual (front & side) sight glass with solenoid coil 120V 50/60 Hz for transcritical CO2 066936
OMC D240CO2 Dual (front & side) sight glass with solenoid coil 220-240V 50/60 Hz for transcritical CO2 066937
OMC D24NH3 Dual (front & side) sight glass with solenoid coil 24V 50/60 Hz for ammonia 066992
OMC D120NH3 Dual (front & side) sight glass with solenoid coil 120V 50/60 Hz for ammonia 066938
OMC D240NH3 Dual (front & side) sight glass with solenoid coil 220-240V 50/60 Hz for ammonia 066939
Service Parts Description
PS-01525-2 Sight glass O-ring 020877
OM ORings KS-30368-1, Mounting O-rings (3 pieces) 064812
KS-30112 Solenoid Repair Parts Kit for OMC 049191
OM Repair CO2 KS-30401, Solenoid Repair Parts Kit for OMC CO2 066946
OM Repair NH3 KS-30402, Solenoid Repair Parts Kit for OMC NH3 066947
KS-30379 Spare Bolts Parts Kit 065770