VPN = 1000 V
For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation
between the primary and the secondary circuit.
Features Applications
Application Domain
Page 1/8
16August2012/version 0 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com
DVL 1000
1000 V
Maximum steady state input voltage (-40 .. 85 °C) VPN
see derating on figure 2
Isolation characteristics
Parameter Symbol Unit Min Comment
RMS voltage for AC isolation test 50/60Hz/1 min Vd kV 8.5 100 % tested in production
Mass m g 270
Standards EN 50155: 2007
EN 50121-3-2:2006
EN 50124-1: 2001
EN 50178: 1997
Page 2/8
16August2012/version 0 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com
DVL 1000
14 -3 dB
Frequency bandwidth BW kHz 8 -1 dB
2 -0.1 dB
Start-up time ms 190 250 *
Page 3/8
16August2012/version 0 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com
DVL 1000
250 1.20
Max Max
Electrical offset drift (uA)
Typical Mean
150 0.80
Overall accuracy (%)
Min Min
0.40
50
0.00
-50
-0.40
-150
-0.80
-250 -1.20
-50 -25 0 25 50 75 100 -50 -25 0 25 50 75 100
0.8
Max
0.6 Mean
Min
Sensitivity drift (%)
0.4
0.2
0.0
-0.2
Input VP: 200 V/div
-0.4 Output IS: 10 mA/div
-0.6 Timebase: 20 µs/div
-0.8
16August2012/version 0 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com
DVL 1000
45 35
40 30
35
25
30
25 20
20 15
15 Vc = 15 V
TA = 25°C, VP = 0 V 10
10
Vc = 24 V
5 5
0 0
0 5 10 15 20 25 30 -50 -25 0 25 50 75 100
Supply voltage ( V) Ambient temperature (°C)
Figure 7: Supply current function of supply voltage Figure 8: Supply current function of temperature
10 180
0 120
-10
60
Phase (deg)
Gain (dB)
-20
0
-30
-60
-40
-50 -120
-60 -180
0.01 0.1 1 10 100 0.01 0.1 1 10 100
Frequency (kHz) Frequency (kHz)
Figure 9: Typical frequency and phase response
0.1 0
0 -10
-0.1
-20
-0.2
-0.3 -30
Gain (dB)
Phase(deg)
-0.4 -40
-0.5 -50
-0.6 -60
-0.7
-0.8 -70
-0.9 -80
-1 -90
0.01 0.1 1 10 0.01 0.1 1 10
Frequency (kHz) Frequency (kHz)
Figure 10: Typical frequency and phase response (detail)
Page 5/8
16August2012/version 0 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com
DVL 1000
Figure 11: Typical common mode perturbation Figure 12: Detail of typical common mode perturbation
(1000 V step with 6 kV/µs RM = 100 Ω) (1000 V step with 6 kV/µs, RM = 100 Ω)
-100 1E-4
-105
-110 1E-5
Vn (dBVrms/rtHz)
-115
-120
-125 1E-6
-130
-135 1E-7
-140
-145
-150 1E-8
0.001 0.01 0.1 1 10 100 0.001 0.01 0.1 1 10 100 1000
Page 6/8
16August2012/version 0 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com
DVL 1000
10 %
tra t
I
100 %
90 %
Ip Is Page 7/8
16August2012/version 0 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
tr www.lem.com
10 %
tra t
DVL 1000
Connection
●● General tolerance ± 1 mm
●● Transducer fastening 2 holes ∅ 6.5 mm
2 M6 steel screws This transducer must be used in electric/electronic equipment
Recommended fastening torque 4 Nm with respect to applicable standards and safety requirements
●● Connection of primary 2 M5 threaded studs in accordance with the manufacturer’s operating instructions.
Recommended fastening torque 2.2 Nm
●● Connection of secondary 3 M5 threaded studs
Recommended fastening torque 2.2 Nm
Caution, risk of electrical shock
Remarks
When operating the transducer, certain parts of the module
●● IS is positive when a positive voltage is applied on +HV.
can carry hazardous voltage (eg. primary busbar, power
●● The transducer is directly connected to the primary voltage.
supply). Ignoring this warning can lead to injury and/
●● The primary cables have to be routed together all the way.
or cause serious damage. This transducer is a build-in
●● The secondary cables also have to be routed together all the
device, whose conducting parts must be inaccessible after
way.
installation. A protective housing or additional shield could
●● Installation of the transducer is to be done without primary or
be used. Main supply must be able to be disconnected.
secondary voltage present.
Page 8/8
16August2012/version 0 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com