Electrical data
Type Primary nominal Primary current, Features
RMS current measuring range 1)
●● Hall effect measuring principle
IPN (A) IPM (A)
●● Insulating plastic case recognized
HAX 500-S 500 ±1500
according to UL 94-V0.
HAX 600-S 600 ±1800
HAX 850-S 850 ±2550 Advantages
HAX 1000-S 1000 ±3000
HAX 1500-S 1500 ±4500 ●● Low insertion losses
HAX 2000-S 2000 ±5500 ●● Easy installation
HAX 2500-S 2500 ±5500 ●● Low power consumption
U C Supply voltage (±5 %) 1) ±15 V ●● Small size and space saving
IC Current consumption < +20/−15 mA ●● Only one design for wide current
ÎP Overload capability 30000 At ratings range
RIS Insulation resistance @ 500 V DC > 1000 MΩ ●● High immunity to external
Vout Output voltage (Analog) @ ±IPN, RL = 10 kΩ, TA = 25 °C ±4 V interference.
Rout Output internal resistance appr. 100 Ω
Applications
RL Load resistance > 1 kΩ
●● AC variable speed drives and
Accuracy - Dynamic performance data servo motor drives
X Accuracy @ IPN, TA = 25 °C (excluding offset) 2) < ±1 % of IPN ●● Static converters for DC motor
εL Linearity error 3) (0 … ±IPN) < ±1 % of IPN drivers
VOE Electrical offset voltage @ TA = 25 °C < ±20 mV ●● Battery supplied applications
VOH Hysteresis offset voltage @ IP = 0, ●● Uninterruptible Power Supplies
after an excursion of 1 × IPN < ±30 mV (UPS)
TCVOE Temperature coefficient of VOE < ±1 mV/K ●● Switched Mode Power Supplies
TCVout Temperature coefficient of Vout (% of reading) < ±0.1 %/K (SMPS)
tr Step response time to 90 % of IPN 4) < 5 µs ●● Power suppliers for welding
BW Frequency bandwidth (−3 dB) 5) DC … 25 kHz applications.
Application domain
General data
●● Industrial.
TA Ambient operating temperature −25 ... +85 °C
TS Ambient storage temperature −25 ... +85 °C
m Mass appr. 450 g
Standards UL 508: 2013
Notes: 1) Operating at ±12 V < UC < ±15 V will reduce the measuring range
2)
The primary busbar fixed in the center of aperture is recommended. The
position of busbar has impact on the accuracy of transducer
3)
Linearity data exclude the electrical offset
4)
For a di/dt = 50 A/µs
5)
Please refer to derating curves in the technical file to avoid excessive core
heating at high frequency.
5)
Variation of the offset during the test IEC 61000-4-3 between 100 to 200
MHz: 8 % of ISN.
N° 74.75.50.000.0, N° 74.75.52.000.0, N° 74.75.57.000.0, N° 74.75.60.000.0, N° 74.75.65.000.0, N° 74.75.69.000.0, N° 74.75.70.000.0 Page 1/3
9December2016/version 23 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com
Current Transducer HAX 500 … 2500-S
Insulation coordination
U d RMS voltage for AC insulation test, 50 Hz, 1 min 5 kV
ÛW Impulse withstand voltage 1.2/50 µs 8.3 kV
Ue Partial discharge extinction RMS voltage @ 10 pC > 660 V
Min
dCp Creepage distance 15.7 mm
dCI Clearance 12.7 mm
CTI Comparative tracking index (group IIIa) 275
Applications examples
Safety
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3
9December2016/version 23 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com
Dimensions HAX 500 … 2500-S (in mm)
第一视角
第三视角
第一视角
第三视角
Connection
IP UC
RM
UC
dCl dCp
Page 3/3