You are on page 1of 1

SCRIBBLE CORN

ER

BINS

710 710 710 710 SCRIBBLE CORNER

UP
COLLABORATIVE
AREA
STANDUP
SCRUM COLLABORATIVE
4pax AREA
ACOUSTIC SCREEN

SB1
SHAFT FOR SPACE FOR UPS
SHAFT FOR LVWS-L3-01

950

SB2

SB2

SB2
TEAM MEET TEAM MEET
EARTHING EARTHING 200 kVA UPS 1500 MM PASSAGE 1500 MM PASSAGE
RESEARCH TEAM

LMS PANELROOM
(21 + 1)

CWD BIN
FIRE MARSHAL FIRE MARSHAL
PRINTER
LOCKER LOCKER ENCLOSED
4 PAX OFFICE COLLABORATIVE

1065 ISO-TXWS-L3-01 AGILE TEAM AREA

SB1

SB1

DB STORAGE

DB STORAGE
(HT adjustable wks) STANDUP

SB1
FOCUS
SCRUM
800 150 kVA ISO.TX. ROOM
4pax

SB2

SB2

SB2
1200(W) x 1000(D) x 1900(H) 720 720 720 720 720 720

950
SHAFT FOR +150 LVL FULL HT

HVAC-IP-L3-01
STORAGE

LIGHTNING PH.RM PH.RM

1200(W) x 500(D) x 2100(H)


200 kVA

200 kVA UPS O/P


LVWS-O/P-L3-01
SPARE
SPARE ±00 LVL DATA
DATA SHAFT

UP550 Kg SHAFT

1500(W) x 500(D) x 2000(H) SB1

choice

choice
seats

seats
2nos

2nos
HVAC-IP-L3-01

LVWS-L3-01 200 kVA UPS O/P SHAFT


FOR RWP
STANDUP
SCRUM
5PAX
HUDDLE ROOM
+150 LVL
SHAFT
FOR RWP

5PAX 4pax
1200(W) x 500(D) x 2100(H) 8mm THK. HUDDLE ROOM TEAM MEET

SB1
TEAM MEET
1500 MM PASSAGE ±00 LVL

LVWS-O/P-L3-01

SB2

SB2

SB2
TEAM MEET TEAM MEET

CHQD. PLATE

855

LVPA-L3-01
SPARE

ENCLOSED

2
DATA

150 kVA
SPARE

METAL
BINS
SHAFT

40 kVA UPS O/P


2050

DATA

PA RACK

RACK
OFFICE

SB1
SHAFT
ENCLOSED

ISO.TX. 1050(W) x 500(D) x 2100(H)


FULL HT FULL HT DN
OFFICE
DN

SB1 STORAGE STORAGE


CWD BIN
UP UP

1050(W) x 500(D) x 2100(H)


750 kg LVIT-O/P-L3-01

PRINTER
STAIRCASE - 1

1500 MM PASSAGE
40 kVA UPS O/P
STAIRCASE - 4

1500 MM PASSAGE
METAL RACK METAL RACK

LVIT-O/P-L3-01

PRINTER
PRINTER/
ISO-TXWS-L3-01 SB1 COPY

METAL
RACK
MULTIMEDIA FOCUS PRINTER/
AREA

ELECTRICAL
±00 LVL ROOM
CWD BIN
±00 LVL

CWD BIN
SPARE SPARE ROOM COPY

METAL RACK
FIRE SPARE
DATA DATA FIRE SPARE SPARE
DATA

SB2

SB2

SB2
SHAFT SHAFT SHAFT
65 SQFT AREA SHAFT
SHAFT DATA SHAFT DATA SHAFT

855
BINS

'1' +150 LVL +150 LVL

METAL
ROOM

SB2

SB2

SB2

SB2

SB2
RACK
1500 MM PASSAGE 1500 MM PASSAGE

730
BINS

LOCKERS FIRE MARSHAL LOCKER


680 1200 1200 795

FULL HT
5000(W) x 650(D) x 2375(H)
STORAGE

SB1
RACK

SB1
BINS
RACK

INVERTER
INV-L3-01
4 PAX
880 PRINTER/ SHREDDING

10 KVA
SB2

SB2

SB2
AGILE TEAM
LVA-L3-01 - 1658KG

150 kVA UPS TRAFO O/P-600 kg

LOW HT STORAGE

LOW HT STORAGE

LOW HT STORAGE
16 PAX MEETING

8mm THK.
COPY RACK
ROOM

800
AREA CWD BIN
ROOM (HT adjustable wks) 137 SQFT
LMS PANEL
SPACE FOR

730
RACK

SB2

SB2

SB2

SB2

SB2

1331
40 kVA
BATTERY RACK-1 FOR 200KVA UPS
CHQD. PLATE
ENCLOSED

2200(W) x 450(D) x 2100(H)


UPS

BATTERY RACK-2 FOR 40KVA UPS


PRINTER
OFFICE COMMS CLOSET

BCB
ISO-TXWSOP-L3-01

1031
70 kg
2100(W) x 540(D) x 2000(H) 220300SF500
LVIT-L3-01
HVAC
500

1600(W) x 400(D) x 2000(H)


1660 135

LVIT-L3-01

SB1

1500 kg - (UPSB001-1-02)
UPSA001-1-01

METAL
SB1

SB1
HVAC

300
RACK

300
METAL RACK METAL RACK METAL RACK
+300 LVL

40 kVA UPS SHAFT-2 +150 LVL


PDU-UB-L3-01 PDU-UA-L3-01 CSI-AP-L3-01
SHAFT-1

METAL RACK
FIRE MARSHAL LOCKER

SB1
40 kVA BATTERY RACK-1 FOR 200KVA UPS
5PAX
HUDDLE ROOM
1800 MM PASSAGE 1800 MM PASSAGE 1800 MM PASSAGE PRINTER/ PANDEMIC

BCB
SB2

SB2

SB2
5600

COPY
UPS

SB2

METAL RACK
STORE
2100(W) x 540(D) x 2000(H)

800
+150 LVL

SB2

SB2

SB2

SB2
AREA

SB1

SB1
105 SQFT

'1'

730
LOW HT STORAGE PRE PAY
Iso Tx. UPSA001-1-02 FULL HT STORAGE
4400

METAL
BINS

RACK
– PRE ORDER PROPERTY SERVICES FULL HT FULL HT PRINTER

METAL
RACK
FULL HT
FOCUS
CWD BIN
STORAGE STORAGE STORAGE
COUNTER BAGGAGE (TECHNICAL
ISO-TXIT-L3-01 10 KVA
PH.RM ROOM 4 PAX
AGILE TEAM
LOCKERS LOCKERS SCANNER 4PAX INFORMAL ENCLOSED LOCKERS CONSUMABLES STORE)

METAL
OFFICE

RACK
±00 LVL MEETING ROOM

SB1 4pax 4pax (HT adjustable wks) 77 SQFT


INVERTER OUTPUT PANEL IT 2000 360

METAL
RACK
Seating Seating METAL RACK METAL RACK METAL RACK

DISPOSAL
INV-OP-L3-01
BATTERY RACK-1 FOR 200KVA UPS

460

BATTERY RACK-2 FOR 40KVA UPS


BCB
2100(W) x 540(D) x 2000(H)

1600(W) x 400(D) x 2000(H)


COMMUNITY

1500 kg - (UPSB001-1-02)
UPSA001-1-01

METAL
ROOM
CEILING

RACK
3000
MOUNTED
METAL RACK METAL RACK METAL RACK
MANAGER 32" LCD

1550
BATTERY RACK-1 FOR 200KVA UPS

BCB
148 SQFT CHANGING ROOM -

SB1
CHANGING ROOM -
2100(W) x 540(D) x 2000(H)
4pax 4pax METAL RACK METAL RACK UPSA001-1-02

MICRO 5PAX

METAL
RACK
Bench Bench
SUPPORT STAFF SUPPORT STAFF
Seating Seating
MARKET TROLLEY & HUDDLE ROOM FEMALE
EGS

1134
MALE

METAL RACK

MIRRIOR
SB2

SB2

SB2

SB2

SB2
SB2

SB2

SB2
METAL RACK METAL RACK METAL RACK

METAL
BIN ROOM

RACK
SPACE
BATTERY ROOM

METAL
CSI SECURITY 106 sqft

800
FOR MAP

730
STORE

BATTERY RACK-2 FOR 40KVA UPS


SECURITY 103 sqft

RACK
(A1 SIZE))

1600(W) x 400(D) x 2000(H)


1200 BATTERY ROOM

1500 kg - (UPSB001-1-02)
57 SQFT +150 LVL 1 ROOM 170 SQFT
75 SQFT +150 LVL

METAL
+150 LVL

RACK

1550
PROPERTY SERVICES 113 SQFT

METAL RACK
1500

8mm THK.
FULL HT SPACE FOR
DB STORAGE (HOUSEKEEPING STORE) FULL HT STORAGE CIM SMART FULL HT FULL HT

BATTERY RACK-2 FOR 40KVA UPS


SECURITY STORAGE (CSI)
UMBRELLA STANDS REPEATER FULL HT FLS EMERGENCY MAIL DROP BOX LOCKERS STORAGE STORAGE
KEY CABINET FULL HT LOCKER
(600 X 450 BATTERY INVERTER FOR

72 SQFT 2 (CSI) PANEL STORAGE


EVACUATION
EQUIPMENT
PRINTER
STORAGE X 580mm)

+150 LVL
10KVA
INVA001-1-01
LOCKERS FOR

1600(W) x 400(D) x 2000(H)


SB1 ±00 LVL

1500 kg - (UPSB001-1-02)
±00 LVL ±00 LVL SECURITY TEAM ±00 LVL
2500

170 SQFT
(12 NOS.)

CHQD. PLATE LVWS-I/P-L3-01


WORK CAFE

UPS I/P PANEL


1700 MM PASSAGE 1700 MM PASSAGE 1700 MM PASSAGE

METAL
RACK
42 seats

LVWS-L3-01
CUTLERY
DB PANEL

200 KVA UPS INPUT PANEL IT STORE

SB2 SB2
MICROWAVE MICROWAVE MICROWAVE

SB2 SB2
200KVA
BUILT-IN BUILT-IN BUILT-IN

METAL RACK
SB1
REFRIDGRATOR
±00 LVL

500
SLIDING DOOR SLIDING DOOR
ROOM
85 SQFT

METAL
1200(W) x 500(D) x 2100(H)

RACK
FRESH CUPS
SHAFT FOR

SB2

SB2

SB2

BOILER
FIRE
ADA BMS FIRE

SB1
AHU ROOM

40 kVA UPS TRAFO O/P-200 kg


SHAFT-1 SHAFT-1
800
AHU ROOM

FRESH CUPS

Tea Machine
Chai Point
TOILET +150 LVL

SB1

METAL RACK
01 02
SERVICE LADIES GENTS SERVICE

CUTLERY
LIFT - 6

METAL
BEAN TO
COFFEE
LIFT - 1

RACK
SHAFT FOR
LIFT LIFT

8mm THK.
SHAFT FOR TOILET TOILET DG CABLE

1500(W) x 450(D) x 2100(H)

CUTLERY
REL. CABLE
1 2 WATER
STAIRCASE - 2 STAIRCASE - 3

ISO-TXITOP-L3-01
DISPENSER

500

C.O.P.
C.O.P.
ZIP TAP
SB1
BATTERY INVERTER FOR
CHQD. PLATE UP UP

COUNTER BIN
BELOW
10KVA DN DN MOTHER'S
ROOM

SB1 LVIT-I/P-L3-01
SHAFT FOR
SPACE FOR UPS
INVA001-1-01
SHAFT FOR LVWS-L3-01
EARTHING
91 sqft

+150 LVL
EARTHING 200 kVA UPS

1350
LMS PANELROOM

UPS I/P PANEL


LIFT - 2 LIFT - 5

SB2

SB2

SB2
40 KVA UPS INPUT PANEL ISO-TXWS-L3-01

SB1
1365 925 1515 150 kVA ISO.TX.
800

LIFT LOBBY

LVIT-L3-01
SHAFT FOR
1200(W) x 1000(D) x 1900(H)
500 HVAC-IP-L3-01 LIGHTNING SHAFT FOR SHAFT FOR

1200(W) x 500(D) x 2100(H)


PHE PHE 200 kVA

200 kVA UPS O/P


LVWS-O/P-L3-01
1500(W) x 500(D) x 2000(H)
1100(W) x 500(D) x 1800(H)
UP550 Kg

HVAC-IP-L3-01
40KVA

850
SINK SERVICES SERVICES

C.O.P.
C.O.P.
LVWS-L3-01 200 kVA UPS O/P

300

305
800 1200(W) x 500(D) x 2100(H)

±00 LVL
LVWS-O/P-L3-01

1500

LVPA-L3-01
150 kVA 40 kVA UPS O/P

PA RACK
ISO.TX. 1050(W) x 500(D) x 2100(H)

1000

900
MEDICAL

1050(W) x 500(D) x 2100(H)


750 kg LVIT-O/P-L3-01

40 kVA UPS O/P


LVIT-O/P-L3-01
ISO-TXWS-L3-01
ELECTRICAL 10 kVA INVERTER
ROOM

METAL
RACK
650(W) x 300(D) x 900(H)
ROOM

400
103 SQFT

5000(W) x 650(D) x 2375(H)


UTILITY LIFT - 4
LIFT - 3

LVA-L3-01 - 1658KG

INVERTER
INV-L3-01
10 KVA
650
150 kVA UPS TRAFO O/P-600 kg
LMS PANEL
ROOM WITH

SPACE FOR
CUT OUT FOR 40 kVA

WASTE PIPE IN CUT OUT FOR

2200(W) x 450(D) x 2100(H)


UPS

SB1

ISO-TXWSOP-L3-01
70 kg
LVIT-L3-01
HVAC LVIT-L3-01 HVAC WASTE PIPE IN
DISH WASHER FALSE CEILING

200
SHAFT-1 300 SHAFT-2 FALSE CEILING

500 500
40 kVA UPS 10 kVA INVERTER
4pax 40 kVA

5000

2200
UPS ISOLATOR

C.O.P.

C.O.P.

600
Bench 1000
SHOWER
SB2

SB2

SB2
Iso Tx.
715

SPACE UNDER ISO-TXIT-L3-01


Seating CRUSHER 10 KVA

SHOWER
FOR COUNTER
INVERTER OUTPUT PANEL
TROLLEY DISH WASH INV-OP-L3-01
1415 STORAGE
350

300
LOW HT.

DB PANEL
450

479
LVWS-I/P-L3-01

UPS I/P PANEL


DB PANEL

LVWS-L3-01
SHAFT FOR SHAFT FOR 200 KVA UPS INPUT PANEL

200KVA
1200
VENTILATION VENTILATION 1200(W) x 500(D) x 2100(H)

1650

40 kVA UPS TRAFO O/P-200 kg


1500(W) x 450(D) x 2100(H)
2508

ISO-TXITOP-L3-01
ODU ODU

1500
LVIT-I/P-L3-01

UPS I/P PANEL


40 KVA UPS INPUT PANEL

LVIT-L3-01
650 1100(W) x 500(D) x 1800(H)

40KVA
1100
SB1
1650

383 500

350
DB PANEL

880 880 880 740

PLAN SHOWING GRILLAGE TOP LEVEL PLAN SHOWING GRILLAGE TOP LEVEL PLAN SHOWING GRILLAGE TOP LEVEL
(DETAIL 'A') (DETAIL 'B') (DETAIL 'C')
SCALE 1:50 SCALE 1:50 SCALE 1:50

800 800 800 800 855

SB1 (TYP) SB2 8mm THK. 25Ø-450 C/C 8mm THK.


CHQD. PLATE CHQD. PLATE
PLUG WELD (TYP)

LEGEND :-
STEEL STEEL IMPORTANT NOTE:
SB1 BEAM NO. MEMBERS
1.) EXISTING FLOOR FINISH NEEDS TO BE STRICTLY REMOVED.
SB1 & SB2 ISMB 125
2.) THIS DRAWING IS VALID ONLY FOR PROPOSED LOADINGS AS PER
SECTION 1-1 EXISTING SLAB DETAIL '1' DRAWING ACM-EL-308-C,ACM-AC-301-C & DFSPL MS.
SCALE 1:15 SCALE 1:15 3.) CONNECTION BETWEEN CHEQUERED PLATE AND ISMB 175
SHALL BE PLUG WELD @ 450 MM C/C.

GENERAL NOTES FOR STRUCTURAL STEEL :-


1) GENERAL CONSTRUCTION IN STEEL SHALL CONFIRM TO IS:800
2) CONTRACTOR SHALL ENSURE THAT THE STEEL BEING USED IN CONSTRUCTION
IS STRAIGHT,FREE FROM TWISTS, CRACKS, SURFACE FLAWS,
LAMINATIONS, IMPERFECT EDGES AND OTHER DEFECTS.
3) ALL FABRICATED PARTS SHALL BE NUMBERED AS INDIVIDUAL MEMBERS AND
ALSO AS PART OF AN ASSEMBLY, TO FACILITATE THE IDENTIFICATION OF
EACH PART UNIQUELY.
4) ERECTION CLEARANCES SHALL NOT BE MORE THAN 2 MM.
5) ALL MEMBERS SHALL PREFERABLY BE MACHINE CUT. IF FLAME-CUTTING IS
REQUIRED TO BE RESORTED TO, THE EDGES SHALL BE MACHINED TO A DEPTH
OF 3 MM MINIMUM. THE BUTTING SURFACES AT ALL JOINTS SHALL BE PLANED
SO AS TO BUTT IN CLOSE CONTACT THROUGHOUT THE FINISHED JOINT.
6) WHEREVER IT IS NOT MENTIONED, ALL JOINTS AND CONNECTIONS SHALL BE
FULLY WELDED AFTER ERECTION.
7) CONTRACTOR SHALL ENSURE DURING THE ERECTION OF STRUCTURAL MEMBERS
OR WHILE USING THE STRUCTURAL MEMBERS FOR SUPPORTING OTHER STAGING
THAT NO MEMBER IS OVERSTRESSED. DURING THE ERECTION OF THE STRUCTRE
THE STEELWORK SHALL BE SECURELY BOLTED, FASTENED OR TEMPORARILY
BRACED AS DIRECTED BY PROJECT MANAGER.
8) ALL WELDS SHALL BE 6 MM THK. CONTINUOUS FILLET WELDS UNLESS NOTED OTHERWISE.
9) ALL WELDING SHALL BE CARRIED OUT USING METAL ARC PROCESS AND SHALL BE IN
ACCORDANCE WITH IS:816 AND IS: 817.
10) FABRICATION AND ERECTION TOLERANCES SHALL BE AS PER IS: 7215.
11) ALL STRUCTURAL STEEL BEAMS AND THEIR EXPOSED
CONNECTIONS SHALL BE COVERED WITH APPROPRIATE FIRE
RETARDING VERMICULITE / MANDOLITE BASED SPRAY TO
ACHIEVE TWO HOUR FIRE RATING.
12) GRADE OF ALL STRUCTURAL STEEL MEMBERS SHALL BE Fe 250 U.N.O.

NO REVISIONS BY CHK DATE


A0 FOR APPROVAL VT SK 27-01-22
DRAWN BY : VISHAL
ARCHITECT : PROJECT :

NIRLON KNOWLEDGE PARK,


TITLE :
STERLING
R0 RELEASED FOR CONSTRUCTION VT SK 09-02-22
PROPOSED MODIFICATION WORK ENGINEERING CONSULTANCY SERVICES PVT. LTD.
DESIGNED BY : AA BUILDING-B3, LEVEL-3 AT 3RD FLOOR LVL. Unit 26, 6th floor, Kohinoor Commercial Tower II,
CONCEPT CONSILIO INDIA PVT. LTD. Behind Kohinoor City Mall, Off L.B.S. Marg,
Kurla (West), Mumbai – 400 070.
CLIENT : TEL: (022) 66744601 / 4602 / 4603
CHECKED BY : GD DRAWING STATUS:
Email: sterlingbkc@gmail.com
Website: www.sterlingengg.com
MORGAN STANLEY VALID FOR EXECUTION DRAWING NO:
DATE : 08-06-21
8799A/WD/GRL/01 R0