You are on page 1of 1

AC OUTDOOR UNIT



BAL
E

S/W41A
S/W41
S/W
AC OUTDOOR UNIT
A/C BED ROOM-3 S/W38 S/W37

S/W
E

S/W S/W
S/W12 S/W25 A/C
BED ROOM-1
S/W
S/W24 S/W36

S/W
S/W
S/W
S/W6 S/W7
S/W
A/C D
S/W5 S/W8

D

S/W
S/W42A S/W39
C

S/W
LIVING/DINING
D D

S/W
S/W27 TOILET-1 D
D S/W35

S/W
C S/W34A S/W34B
S/W23 S/W34
D

S/W
S/W
S/W22 S/W42 S
S S S/W

S/W
 
S/W4
S/W9 S/W21A D
S/W40

S/W
S/W10 S/W28 S/W S/W S/W33 S/W
S/W21 S/W
PASSAGE
C2
S/W S/W S/W

S/W32 S/W44A
S/W43
S/W3 S/W31 S DB-C S/W43A

S/W
S/W2 SWITCH G (L&P) 
S/W S/W
S/W S/W S/W S/W S S/W44
D S/W13
S/W20 S/W29 S/W30 C S/W45
ENTRANCE C TOILET-2
LOBBY TOILET-3 D

S/W
H S/W49 D

S/W
S/W18

S/W
S/W50 S/W46
S/W17 KITCHEN A/C

S/W
S/W16 C

535
S/W
S/W14

S/W
S/W1 BED ROOM-2
S/W S/W15 S/W47
S/W48
GAS METER

S/W S/W
RI AC OUTDOOR UNIT


ELECTRICAL LAYOUT FOR FLAT NO. 102,


ROOM CONTROLLED BY DESCRIPTIONS MODULAR HEIGHTS NOTE
ROOM CONTROLLED BY DESCRIPTIONS MODULAR HEIGHTS NOTE ROOM CONTROLLED BY DESCRIPTIONS MODULAR HEIGHTS NOTE
LEGEND FOR ELECTRICAL
SWICHT BOARD NOS. BOX SWICHT BOARD NOS. BOX SWICHT BOARD NOS. BOX S.NO DESCRIPTION SYMBOL
2 NOS. CEILING LIGHTS 8M 1100 S/W 23 1 BRACKET LIGHT (T.W.) 6M 1100 65MM DIA. , DEPTH- 63MM
LOBBY S/W 01 1 CEILING PT. (T.W.) 2M 1100 TWO WAY KITCHEN S/W 13 TWO WAY 1. 1 X 36 WATT FLOURESCENT FIXTURE ON CEILING
2 NOS. BRACKET LIGHT BED ROOM -3 1 BRACKET LIGHT
JUNCTION BOX
1 BELL CONTROL 1 EXHAUST FAN 2 CEILING LIGHT
65MM DIA. , DEPTH- 63MM
1 CEILING FAN JUNCTION BOX
1 CEILING FAN 100MM DIA. , DEPTH- 75MM
1 CEILING PT. TWO WAY 1 AQUAGUARD SWITCH PT. S/W 24 1NOS. 6 AMP. OUTLET 3M 300 3 CHANDELIER LIGHT ON CEILING JUNCTION BOX
LIVING RM S/W 02 4M 1100
65MM DIA. , DEPTH- 35MM
1 BRACKET LIGHT 4 BRACKET LIGHT
S/W 14 6AMP SOCKET PT. FOR AQUAGUARD 2M 2240 S/W 25 AC POINT 2M 2240 JUNCTION BOX
100MM DIA. , DEPTH- 75MM
5 CEILING FAN JUNCTION BOX
S/W 03 6 AMP. OUTLET 3M 300 1NO. 16 AMP/6 PIN OUTLET 4M
S/W 15 6 EXHAUST FAN
1100
T.V. OUTLET 2M 1NOS. 6 AMP. OUTLET 3M S/W 27 T.V. OUTLET 2M 65MM DIA. , DEPTH- 35MM
S/W 04 300 300 7 CEILING ROSE
2NOS. 6 AMP. OUTLET 6M 2NOS. 6 AMP. OUTLET 6M JUNCTION BOX

TELEPHONE OUTLET 2M S/W 16 1NOS. 6 AMP. OUTLET 3M 2240 8 DISTRIBUTION BOARD DB


S/W 05 300
2 NOS. 6 AMP. OUTLET 6M S/W 28 6 AMP. OUTLET 3M 300 9 VIDEO DOOR PHONE
S/W 17 1NOS. 16 AMP/6 PIN OUTLET 4M 300
S/W 06 1 CEILING PT. 1 EXHAUST FAN 3M 1100 10 BELL POINT
65MM DIA. , DEPTH- 35MM
TOILET - 3 S/W 29 JUNCTION BOX
1 CEILING FAN 6M 1100 1 GEYSER PT. (T.W.)
S/W 18 1NOS. 16 AMP/6 PIN OUTLET 4M 300 11 FOOT LIGHT
1 BRACKET LIGHT
65MM DIA. , DEPTH- 63MM
12 SMOKE DETECTOR ON CEILING S
S/W 07 KITCHEN S/W 30 1 BRACKET LIGHT 4M 1100 JUNCTION BOX
DINING RM AC POINT 2M 2240 BALCONY 1NOS. 6 AMP. OUTLET 13 HEAT DETECTOR ON CEILING H 65MM DIA. , DEPTH- 63MM
JUNCTION BOX
S/W 08 6 AMP. OUTLET 3M 300 S/W 20 1 NOS. 16 AMP/6 PIN OUTLET 4M 300 RI
14 RESPONSE INDICATOR
S/W 09 1 CEILING PT.(T.W.) 1 BRACKET LIGHT (T.W.) PASSAGE
8M 1100 S/W 21 2M 1100 TWO WAY S/W 31 2M 1100
15 HOME GATEWAY G
1 BRACKET LIGHT 1 CEILING PT. (T.W.) TWO WAY
BED ROOM -3 1 FOOT LIGHT
3 CEILING PT. 16 SWITCH SWITCH
1 CEILING FAN 1NOS. 6 AMP. OUTLET 3M S/W 32 1 CEILING PT. (T.W.) 2M 1100 TWO WAY
S/W 21A 17 PULL BOX 150 X 150 X 50MM
300
VIDEO DOOR PHONE 2M 1280 1 FOOT LIGHT FITTING 2M
S/W47 T.V. OUTLET 2M 18 SWITCH BOARD S/W (L X H X D)
300
S/W 10 6 AMP. OUTLET 3M 300 2NOS. 6 AMP. OUTLET 6M
S/W 22 TELEPHONE OUTLET 2M BED ROOM -2 1/2 MODULE 75 X 75 X 51MM
300 AC POINT 2M
LIVING BALCONY 1NOS. 6 AMP. OUTLET 3M S/W48 2240 3 MODULE 95 X 75 X 51MM
S/W12 6 AMP. OUTLET 3M 300 BED ROOM 2M 1100
S/W 41 1 BRACKET LIGHT (T.W.) 2 BRACKET LIGHT 4 MODULE 134 X 75 X 51MM
BALCONY
S/W 33 1 CEILING PT. 2M 1100 TOILET - 2 S/W 49 1NOS. 6 AMP. OUTLET 8M 1100 6 & 8 MODULE
S/W 41A 1NOS. 6 AMP. OUTLET 3M 300 1 EXHAUST FAN
210 X 75 X 51MM
BED ROOM-1
S/W 34 1 BRACKET LIGHT (T.W.) 3M 1100 TWO WAY 1 GEYSER PT. (T.W.)
1BRACKET LIGHT 2 BRACKET LIGHT
8M 1100
1 FOOT LIGHT S/W 42 1NOS. 6 AMP. OUTLET
TOILET - 1 S/W 50 1 GEYSER SOCKET PT. 3M 2400
1 EXHAUST FAN
1NOS. 6 AMP. OUTLET 3M 300 TWO WAY 1 GEYSER PT.
S/W 34A
1 FOOT LIGHT FITTING 2M S/W 42A 1 GEYSER SOCKET PT. 3M 2400
2 BRACKET LIGHT (T.W.) 8M 1100
S/W 34B 2 BRACKET LIGHT 1 BRACKET LIGHT (T.W.) 2M 1100
BED ROOM -2 S/W43
1 CEILING FAN 1 FOOT LIGHT SCHEDULE FOR HEIGHT

TELEPHONE OUTLET 2M 1NOS. 6 AMP. OUTLET 3M A = 2'-6" C = 7'-0"


S/W 35 300 S/W43A 300
1NOS. 6 AMP. OUTLET 3M 1 FOOT LIGHT FITTING 2M
B = 4'-6" D = 7'-6"
S/W 36 AC POINT 2M 2240 S/W44 TELEPHONE OUTLET 2M
300
1NOS. 6 AMP. OUTLET 3M E = 8'-2"
S/W 37 1NOS. 6 AMP. OUTLET 3M 300

S/W 38 1NOS. 6 AMP. OUTLET 3M 300 S/W44A 1NOS. 6 AMP. OUTLET 3M 300 NOTE - PULL BOX HEIGHT = 2400 MM

S/W 39 T.V. OUTLET 2M


300 S/W45 1 CEILING FAN 6M 1100
2NOS. 6 AMP. OUTLET 6M
1 BRACKET LIGHT
S/W 40 1NOS. 6 AMP. OUTLET 3M 300 1 BRACKET LIGHT (T.W.)

S/W46 1NOS. 6 AMP. OUTLET 3M 300

ELECTRICAL LAYOUT FOR FLAT NO. 102,


1-2
2-2 3-2
5-2 3-3
5-3 6-3
7-3 NOTES & REFERENCES Status PROJECT
7-1

GENERAL NOTES - GOOD FOR CONSTRUCTION BLUE RIDGE, HINJEWADI, PUNE


0553 0078 0078 0553
0571 0571
0043 °01 0043
°01
0525

F-2 E-3
0571

ynoclaB ynoclaB
0522

E-2
5244

0002

0533
0551
0562

0551
055

055
0571
5744

0023
ynoclaB ynoclaB
5744

D-3
0051

5
0034

1. ALL DIMENSIONS ARE IN MILLIMETERS.


deB retsaM telioT telioT deb retsaM
0044

8706
0538

D-2 mooR moor


0538

moor deB
0538

moor deB
0511

C-3
0511

C-2 moor gniniD moor gniniD


0064

moor gniviL moor gniviL


271

CLIENT:
5271 0

B-3
0001

B-2
0001 5

0073

2. DIMENSIONS ARE TO BE READ AND NOT TO BE SCALED.


moor deB telioT telioT
A-2 telioT telioT

4
001

0052

ynoclaB
7221
nehctiK
ynoclaB
moor deB A-3
057
0551 nehctiK 0551
057
006

006

057 057
0062

0553
057

057

00041 0051
0533 0553
0051

FLAGSHIP INFRASTRUCTURE PVT. LTD.


005

005

0515 0515
1-2 6-2
057
0041

2-2
0051

chf
6-3

3. THE CONTRACTORS MUST VERIFY ALL DIMENSIONS ON SITE AND REFER THE
4-2 4-3

3
5-2 5391
3-3
2-3
0021

.braG 004
5851
5743

RELEVANT STRUCTURAL AND OTHER CONSULTANT'S DRAWINGS BEFORE


0001
0251

mm0911=W
ND PU mm072=T
00601

0062
PU .qE 71=R
0091

5131
0001

COMMENCING ANY WORK OR PREPARING ANY SHOP DRAWING, AND IN CASE 2 HINJEWADI, PUNE
0003
0911 0911

1-AH THGIERF GK0201


0002

)stfiL enoK(TFIL
0091

0062
0151

NIAM GNISIR ROF TUOTUC


ELBAC TFIL &
0091

ANY DISCREPANCY IS NOTICED THE SAME SHALL BE BROUGHT TO THE


0505
051

6901 STALF ROF .DNOC NIAM-BUS

1-1 2-1 3-1 4-1


0081

01-1 11-1 21-1 31-1


TUOTUC MM 005X006
748

NIAM GNISIR ROF


5291

5291
DRAOB RETEM

051
0041
006

G-1 G-1
0051 052 0051

COMMENTS FROM ADVENT


057

057

NOTICE OF THE ARCHITECT AND SHALL BE CLARIFIED BEFORE EXECUTION OF 1 R-0


054

054
5262

5262
0052

054 054

0083 0081 0081


ynoclaB nehctiK nehctiK ynoclaB
0021

0021

006 006
F-1 F-1

ARCHITECTS / CONSULTANTS
007

0085
telioT

WORK.
054
5752

5752

telioT telioT telioT


moor gniniD moor gniniD
57401

57401

E-1 E-1

Rev. No. Date Description By Appd


0595
0021

0021

D-1 D-1
REFER THIS DRAWING ALONG WITH THE OTHER RELEVANT ARCHITECTURAL,
retsaM retsaM

ECADI, Shanghai, China


moor deb moor gniviL moor deb
moor deB moor deB
0034

moor gniviL
5232

5232

C-1 C-1
0593

STRUCTURAL AND THE OTHER SERVICES DRAWINGS BEFORE THE EXECUTION


0533
059 008

059 008

B-1 B-1
0571

ynoclaB ynoclaB
0533 0034
0061

A-1 A-1

OF WORK RELATED TO THIS DRAWING AT SITE.


KEY PLAN FAIRWOOD CONSULTANTS, India
0553 0553 0054 0054 0553 0553
00232

1-1 3-1 5-1 6-1 7-1 8-1 9-1 11-1 31-1

# THIS DRAWING @ FAIRWOOD CONSULTANTS PVT. LTD. Fairwood

STRUCTURAL Y.S.SANE ASSOCIATES


CONSULTANTS
PUNE
ynocla
B
PROJECT MANAGEMENT ADVENT PROJECTS
CONSULTANTS
ynocla
B PUNE

1 telioT 2- RB
BUILDING TYPE HIGHRISE APARTMENT
3- RB
deB re

C-TYPE HA-2
moor d tsaM
eB mooR

SWITCH BOARD CONTROLLING


NALP MOOR GNIVIL/GNINID
DRAWING TITLE:
3 telioT 2 telioT

LAYOUT PLAN OF C2-3BHK FLAT


nehctiK moor d
ynocla eB
B
1- RB

Dwg. No.

Date Rev.
3 BED ROOM FLAT
20-06-09 R-0

Design by Scale NOT TO SCALE

Drawn by GANESH Approved by SHIRGUDKAR

You might also like