Professional Documents
Culture Documents
B1.10.11
- 13amp
GP
LIGHTING 1200 1200
Canopy lighting to be
13amp
B1-022
inter-connected
into general lighting HIGHLEVEL
circuit by on site
B1.02.01
- switched socket 1M
B1.10.10
-
electrician via junction 3m outlet
KITCHEN
box provided. 1200 see note A EQUIPMENT
BEVERAGE
CHILLER Stair 3 1 Ph/ 3Ph
Cable
outlet 1M
B1.10.08
B1.10.27
7.30 1.90 MAIN commando
KITCHEN
CIRCUIT
1100 600 BOARD
CONTROL
PANEL SDU
COOKING
B1.10.07
B1.10.33
5.5 2.90
B1.10.09
EQUIPMENT
3.0
600 600
600
SDU
---
-
---
X3
1M-3M
---
1200 switched socket
1500 outlet BESPOKE
X2 COUNTER
B1.10.16
0.32
B1.10.00 1200
1 Ph/ 3Ph
1M-3M
STAFF CANTEEN /
Security Control Rm commando
B1.10.17
-
DISH WASH 600 B1.02.00
BEVERAGE
B1.10.17
1.50
B1.10.01
-
1200 STO.
1200
STAIR 3
B1.10.18
-
UP
GLUE BOARD
600
ELECTRICAL KEY
B1.10.19
B1.10.18
1.50
1200
1200
LEGEND
GLUE BOARD
GLUE BOARD
GLUE BOARD
Outlet type....
Kw rating
-
B1.10.01
B1.10.01
- -
1200 1200 - height of
connection(mm)
A.F.F.L
B1.12.01
B1.11.01
- -
1200 1200 13amp SWITCHED FUSED SPUR (Flex Outlet)
B1.12.00
B1.11.00 JANITOR'S
B1.02.08
0.80
OES STORE B1.09.00
ICE STATION
ROOM 1200 DIRTY
DRY STORAGE 1 PHASE SOCKET OUTLET
LIFT
B1.09.01
-
1 PHASE CABLE TAIL
FL01
1200
GLUE BOARD
B1.02.09
0.70 1 PHASE ISOLATOR
1200
1 PHASE SWITCHED SOCKET OUTLET
B1.08.04 B1.08.04
-
1200
B1.08.11
-
3m 3 PHASE SOCKET OUTLET
0.25
see note A
B1.08.06
-
600 3 PHASE CABLE TAIL
1200
MEAT
B1.08.10
-
B1.08.00 3 PHASE ISOLATOR
GLUE BOARD
1200
CHILLER MEAT PREP. CLEAN 3 PHASE SWITCHED SOCKET OUTLET
B1.08.01
-
1200
LIFT
SL01
B1.07.03 B1.07.03
- ELECTRICAL RISER (1 or 3 phase)
B1.07.10
CHILLER
B1.07.09
B1.07.00 -
GLUE BOARD
EPO EMERGENCY POWER OFF BUTTON
1200
FISH PREP.
TELEPHONE
B1.07.01
D
-
1200 DATA POINT
GENERAL NOTES
B1.06.12
- - 13amp
GP
B1.06.16
---
B1.06.06
B1.06.15 B1.06.09
-
VEG. TO SUIT THE PROPOSED CATERING
B1.01.02
---
0.5
600 EQUIPMENT.
B1.06.01
1200 -
CHILLER B1.06.00 1200
GLUE BOARD
1200 - THE INFORMATION SHOWN IS
VEG. PREP. -
INDICATIVE AND FOR INTERPRETATION
SERVICE CORRIDOR
0.9
B1.06.15
0.25
DRAWINGS
1200 600 B1.01.00
- TOTAL LOADS TO BE CONFIRMED BY
CHEFS OFFICE
B1.06.14
B1.06.10
B1.14.01
1200 - EQUIPMENT ROMFORD, ESSEX, RM1 3NH SHEIKH ZAYED ROAD, PO BOX 120410
X2
1200
CLINIC UK UAE
B1.05.06
B1.05.06
B1.05.17
0.25 - 0.25 - Tel - +44 (0)20 8591 5593 Tel - +971 (0)4 323 7525
B1.05.01
-
--
B1.05.14 B1.05.14
1.0 Fax - +44 (0)20 8594 3169 Fax - +971 (0)4 323 7560
600 1200 600 1200
1200
GLUE BOARD
600
B1.05.00 PASTRY B1.14.00 client
E
- PAN WASH
1200 Silver Beach Properties Limited
project
B1.05.16
0.5
1200 stainless steel wall fixed large
power socket outlets.
By Electrical contractor
AC by Marriott - Plot No. PJTRH04J
Palm Jumeirah, Dubai
B1.05.07
-
B1.05.08
B1.13.01 B1.13.01
--- services void
1400
stainless steel wall fixed
1200
small/large power socket outlets.
inter-connected FREEZER GENERAL -
By Electrical contractor Electrical Services Layout
into general lighting
circuit by on site COLDROOM Floor water services runs by
mechanical contractor location
600
electrician via junction waste float runs by mechanical
contractor
Basement 1
300
box provided. waste connection
B1.13.00
Male Locker CHILLER FREEZER riser
13amp
scale date drawn
HIGHLEVEL UNIFORM
B1.04.01
-
TYPICAL WORK COUNTER
B1.03.01
-
3m B1.13.02 0.25 ISSUE 1:50 @ A1 10.10.2018 KW
B1.05.25
- 3m
B1.05.20
-
3m 3m
see note A
see note A 1200 SERVICES PRINCIPLE
see note A
see note A status project ref
F 0 1M 2M 3M 4M 5M
drawing number
5795.B1.102
revision
00
cad ref
5213-LWD-AR-MA-1003-DRW-B1