You are on page 1of 2
Radalert 100X™ Nuclear Radiation Monitor The Radalert 100X™ measures alpha, beta, gamma, and X-radiation Its digital display shows readings in your choice of counts per minute (CPM) wSw/hror mR/hr or in accumulated counts. Ared LED blinks and a beeper chirps with each count (the chirp can be muted). An audible alert sounds when the radiation reaches a user-adjustable level. - Monitor personal radiation eet’ exposure Count Rate Sonya - Monitor an area or perimeter Perry - Detect radiation leaks and On contamination off eee ere - Ensure regulatory compliance - Monitor changes in background radiation - Demonstrate principles of nuclear physics - Check for radioactive minerals in the earth Technical Specifications Halogen-quenched Geiger-Muellor tube (LND 712) ‘Mica end window density 15-20 mg/cm" Side waliso0T2"s446 stainess tel 5 Detects Alpha, Beta, Gamma, and X-radiation ; Operating Range: sv/hr: .000-1,100 # rRihe: 0004110 2 CPM: 0t0350.000 : CPS: 003,500 ; Total: _0109,999000 counts hea Calibration:| cesium 137 gamma) Gamma Sensitivity: 1,200 cPwime/hr referenced toCs-137 Accuracy :) 10% typical +15% maximum ‘Alert Range: Useradjustable alert level to 500 uSv/hr 60,000 CPM Count Light: fed LED ashes with each count Ports: + Output: Stereo 3.5 mm jack sends counts to computers, data loggers, ‘other CMOS-compatible devices, earphones, and educational data collection systems, 0:9V, 1 kOhm impedance. + Input: 25 mm mono jack provides calibration input 0-33V,> Ss width rising edge triggered, Anti-Saturation: | Readout holds at fullscae in fields upto 100 times the maximum reading Temperature Range: | -20°t0 150°C, -#°t0+122"F Timer: | Can set sampling periods of 1 minute to 40 hours Averaging Periods: Display updates every 3 seconds, showing the average for the past '90- second time period at normal levels. The Averaging period decreases as the radiation level increases. Power: One -volt alkaline battery; batter life 000 hours typical, 700 hours decreases as radiation level ees Size :) 150%80x 30 mm(59°x32"x12) Weight :| 225.ams(6.02) including battery Options: Computer software and cable available Certifications : CE Certified: Emissions: EN 55011:2009 + Al:2010 (Class B emissions limits); EN 61326-1: 2006 (Class 8) BF Emissions Immunity: EN 61326-1:2006 (Annex C) Portable Test and Measurement Equipment; EN 61000-4-2: 1995 (ESD); EN 61000-4-3: 1997 (EM) RoHS Compliant; Meets WEEE standards, Audio :| Beeper chirps for each count (can be muted) Alett Switches Alpha Window ‘minimum at normal gackground radiation levels at sea level. Battery life car 00400 ) imi Specifications subject to chenge without notice. 103 Morris Strect, Sulte AS Tel: 707.823.0836 7 Sebastopol, CA 95472 USA Fax: 707.823.7207 httpv/medcom.com contact@medeom.com Toll Free:1.87.378.1010 International Medeor, In.

You might also like