Radalert 100X™ Nuclear Radiation Monitor
The Radalert 100X™ measures
alpha, beta, gamma, and X-radiation
Its digital display shows readings
in your choice of counts per minute
(CPM) wSw/hror mR/hr or in
accumulated counts. Ared LED
blinks and a beeper chirps with
each count (the chirp can be muted).
An audible alert sounds when the
radiation reaches a user-adjustable
level.
- Monitor personal radiation
eet’ exposure
Count Rate
Sonya
- Monitor an area or perimeter
Perry - Detect radiation leaks and
On contamination
off
eee ere - Ensure regulatory compliance
- Monitor changes in background
radiation
- Demonstrate principles of
nuclear physics
- Check for radioactive minerals
in the earthTechnical Specifications
Halogen-quenched Geiger-Muellor tube (LND 712)
‘Mica end window density 15-20 mg/cm"
Side waliso0T2"s446 stainess tel 5
Detects Alpha, Beta, Gamma, and X-radiation ;
Operating Range: sv/hr: .000-1,100 #
rRihe: 0004110 2
CPM: 0t0350.000 :
CPS: 003,500 ;
Total: _0109,999000 counts hea
Calibration:| cesium 137 gamma)
Gamma Sensitivity: 1,200 cPwime/hr referenced toCs-137
Accuracy :) 10% typical +15% maximum
‘Alert Range: Useradjustable alert level to 500 uSv/hr 60,000 CPM
Count Light: fed LED ashes with each count
Ports: + Output: Stereo 3.5 mm jack sends counts to computers, data loggers,
‘other CMOS-compatible devices, earphones, and educational data
collection systems,
0:9V, 1 kOhm impedance.
+ Input: 25 mm mono jack provides calibration input
0-33V,> Ss width rising edge triggered,
Anti-Saturation: | Readout holds at fullscae in fields upto 100 times the maximum reading
Temperature Range: | -20°t0 150°C, -#°t0+122"F
Timer: | Can set sampling periods of 1 minute to 40 hours
Averaging Periods: Display updates every 3 seconds, showing the average for the past
'90- second time period at normal levels. The Averaging period decreases
as the radiation level increases.
Power: One -volt alkaline battery; batter life 000 hours typical, 700 hours
decreases as radiation level ees
Size :) 150%80x 30 mm(59°x32"x12)
Weight :| 225.ams(6.02) including battery
Options: Computer software and cable available
Certifications : CE Certified:
Emissions: EN 55011:2009 + Al:2010 (Class B emissions limits);
EN 61326-1: 2006 (Class 8) BF Emissions
Immunity: EN 61326-1:2006 (Annex C) Portable Test and Measurement
Equipment; EN 61000-4-2: 1995 (ESD); EN 61000-4-3: 1997 (EM)
RoHS Compliant; Meets WEEE standards,
Audio :| Beeper chirps for each count (can be muted) Alett Switches Alpha Window
‘minimum at normal gackground radiation levels at sea level. Battery life car
00400
) imi
Specifications subject to chenge without notice. 103 Morris Strect, Sulte AS Tel: 707.823.0836
7 Sebastopol, CA 95472 USA Fax: 707.823.7207
httpv/medcom.com contact@medeom.com Toll Free:1.87.378.1010
International Medeor, In.