Professional Documents
Culture Documents
SR103AM
SR103AM
C US
Conforms to EN60204-1, EN954-1, VDE 0113-1
UL and C-UL listed, BG approved
H
safety monitoring relays
SR103AM
Dual Channel Safety Monitoring Relay
■ Power requirements—the ■ Outputs—the SR103AM has ■ Monitored manual or auto-
SR103AM will accept 3 N/O outputs to route power to matic/manual reset modes are
24 VAC/DC, 115 VAC, or the coils of power contactors, available on the SR103AM.
230 VAC plus 1 N/C auxiliary output for Monitored manual reset re-
signaling purposes quires closure of the reset
■ Inputs—the SR103AM will circuit followed by opening of
accept single or dual N/C inputs ■ External Device Monitoring the circuit. Reset occurs when
or dual inputs from a light (EDM) is provided with a N/C circuit is opened. Auto reset
curtain (see SR102AM for loop between S11/S12 and S21 requires only closure of the
application wiring for a light on the SR103AM reset circuit as reset occurs
curtain) when circuit is closed.
USA Tel. 1/888/510-4357 UK Tel. +44 (0) 1395-273-209 Japan Tel. +81-466-22-1132 For the Latest Information
R
Canada Tel. 1/800/221-7060 Europe Tel. +49 (0) 5258-938-776 China Tel. +86-21-5836-7708 On the Internet: www.sti.com
H12 Singapore Tel. +65-648-44-001 E-mail: sales@sti.com
SR103AM
■ Application
✎ See the SR102AM for
wiring to a light curtain
24VAC/DC, 110VAC, 230VAC
K1 (AUX)
START L1 L2 L3
MOMENTARY K2 (AUX)
PUSH
EB SERIES BUTTON
LATCHING STOP
E-STOP MOMENTARY RESET
BUTTON PUSH
BUTTON
MOMENTARY
PUSH
GUARD A1 S11 S21 S12 S14 13 23 33 41 BUTTON
CLOSED
Power supply Relay control and
K1
11 21 33 (S11 = 24 V) fault monitoring
+
K2 K2
12 22 34
CONTACT
+ PROTECTION
T5009
INTERLOCK
K1 E.G. THERMAL
CUT OUT H
SR103AM
SWITCH
M
FUSE FUSE
K1 K2
✎ For a full explanation of the circuit operating principle and fault detection,
see “Common Circuit Examples” in the Engineering Section of this catalog.
Terminal Connections
13 23 33 41
A1 S13 S11 S21
For the Latest Information USA Tel. 1/888/510-4357 UK Tel. +44 (0) 1395-273-209 Japan Tel. +81-466-22-1132
On the Internet: www.sti.com Canada Tel. 1/800/221-7060 Europe Tel. +49 (0) 5258-938-776 China Tel. +86-21-5836-7708 R
■ Block Diagram
A2 S10 S13 14 24 34 42
H
■ Dimensions — mm/in.
safety monitoring relays
SR103AM
114 22.5
4.5 0.885
99
3.9
35
DIN RAIL MOUNTING
1.38
USA Tel. 1/888/510-4357 UK Tel. +44 (0) 1395-273-209 Japan Tel. +81-466-22-1132 For the Latest Information
R
Canada Tel. 1/800/221-7060 Europe Tel. +49 (0) 5258-938-776 China Tel. +86-21-5836-7708 On the Internet: www.sti.com
H14 Singapore Tel. +65-648-44-001 E-mail: sales@sti.com
SR103AM
■ Specifications
■ Ordering
For the Latest Information USA Tel. 1/888/510-4357 UK Tel. +44 (0) 1395-273-209 Japan Tel. +81-466-22-1132
On the Internet: www.sti.com Canada Tel. 1/800/221-7060 Europe Tel. +49 (0) 5258-938-776 China Tel. +86-21-5836-7708 R