Professional Documents
Culture Documents
WARRANTY
Scale = 1.5-1.75 in. diameter
2 remote,3electric start
M M
TY
TY
LI
LI
Wireless
PORTABLE INVERTER GENERATOR
M YEAR M YEAR
TY
TY
LI
LI
IT N IT
ED A ED AN
WA R R WA R R
A A
ED W RR AN ED W RR AN
IT IT
2 3
M M MODEL NUMBER
TY
TY
LI
LI
EA EA 100261
Y
R • A ÑO
Y
R • A ÑO
GA
GA
A
RA RA
D
NTÍ TA NTÍ TA
A LI MI A LI MI
12039 Smith Ave.
SAVE THESE INSTRUCTIONS Santa Fe Springs CA 90670 USA
Important Safety Instructions MADE IN CHINA 1-877-338-0999
are included in this manual. REV 100261-20200103 www.championpowerequipment.com
A A
ED W RR AN ED W RR AN
IT IT
M M
T
T
FCC Statement
1. This device complies with Part 15 of the FCC Rules. accordance with the instructions, may cause harmful
Operation is subject to the following two conditions: interference to radio communications. However, there
(1) This device may not cause harmful interference. is no guarantee that interference will not occur in a
(2) This device must accept any interference particular installation. If this equipment does cause
received, including interference that may cause harmful interference to radio or television reception,
undesired operation. which can be determined by turning the equipment
2. Changes or modifications not expressly approved by off and on, the user is encouraged to try to correct the
the party responsible for compliance could void the interference by one or more of the following measures:
user’s authority to operate the equipment. –– Reorient or relocate the receiving antenna.
NOTE: This equipment has been tested and found to –– Increase the separation between the equipment and
comply with the limits for a Class B digital device, receiver.
pursuant to Part 15 of the FCC Rules. These limits –– Connect the equipment into an outlet on a
are designed to provide reasonable protection against circuit different from that to which the receiver is
harmful interference in a residential installation. connected.
This equipment generates uses and can radiate radio Consult the dealer or an experienced radio/TV technician
frequency energy and, if not installed and used in for help.
– or –
Call our Customer Care Team Toll-Free at:
1-877-338-0999
Parts Ordering:
Mon – Fri 8:30 AM – 5:00 PM (PST/PDT)
Toll Free: 1-877-338-0999
*We are always working to improve our products. Therefore, the enclosed product may differ slightly from the image on the cover.
100261
Every effort has been made to ensure the accuracy and completeness of the information in this manual, and we
reserve the right to change, alter and/or improve the product and this document at any time without prior notice.
Since CPE/CET highly value how our products are designed, manufactured, operated and are serviced, and also
highly value your safety and the safety of others, we would like you to take the time to review this product manual
and other product materials thoroughly and be fully aware and knowledgeable of the assembly, operation, dangers
and maintenance of the product before use. Fully familiarize yourself, and make sure others who plan on operating
the product fully familiarize themselves too, with the proper safety and operation procedures before each use. Please
always exercise common sense and always error on the side of caution when operating the product to ensure no
accidents, property damage, or injury occurs. We want you to continue to use and be satisfied with your CPE/CET
product for years to come.
Record the model and serial numbers as well as date and place of purchase for future reference. Have this
information available when ordering parts and when making technical or warranty inquiries.
1-877-338-0999
Model Number
100261
Serial Number
Date of Purchase
Purchase Location
For Oil Type see ‘Add Engine Oil‘ section. For Fuel Type see ‘Add Fuel‘ section.
1
100261 ENGLISH
Manual Conventions
This manual uses the following symbols to help differentiate between different kinds of information. The safety symbol
is used with a key word to alert you to potential hazards in operating and owning power equipment.
Follow all safety messages to avoid or reduce the risk of serious injury or death.
DANGER CAUTION
DANGER indicates an imminently hazardous CAUTION used without the safety alert symbol
situation which, if not avoided, will result in death indicates a potentially hazardous situation which, if
or serious injury. not avoided, may result in property damage.
WARNING NOTE
If you have questions regarding your generator, we can
WARNING indicates a potentially hazardous
help. Please call our help line at 1-877-338-0999
situation which, if not avoided, could result in
death or serious injury.
CAUTION
CAUTION indicates a potentially hazardous
situation which, if not avoided, may result in minor
or moderate injury.
2
ENGLISH 100261
Safety Rules
WARNING DANGER
Read this manual thoroughly before operating your Generator produces powerful voltage.
generator. Failure to follow instructions could result
DO NOT touch bare wires or receptacles.
in serious injury or death.
DO NOT use electrical cords that are worn, damaged
or frayed.
DO NOT operate generator in wet weather.
DANGER DO NOT allow children or unqualified persons to
operate or service the generator
Use a ground fault circuit interrupter (GFCI) in damp
Generator exhaust contains carbon monoxide, a areas and areas containing conductive material such
colourless, odourless, poison gas. Breathing carbon as metal decking.
monoxide will cause nausea, dizziness, fainting or Use approved transfer equipment to isolate generator
death. If you start to feel dizzy or weak, get to fresh from your electric utility and notify your utility
air immediately. company before connecting your generator to your
power system.
Operate generator outdoors only in a well ventilated
area.
DO NOT operate the generator inside any building,
WARNING
including garages, basements, crawlspaces and Sparks can result in fire or electrical shock.
sheds, enclosure or compartment, including the
generator compartment of a recreational vehicle.
When servicing the generator:
Disconnect the spark plug wire and place it where it
DO NOT allow exhaust fumes to enter a confined cannot contact the plug.
area through windows, doors, vents or other DO NOT check for spark with the plug removed.
openings. Use only approved spark plug testers.
DANGER CARBON MONOXIDE: using a generator
indoors CAN KILL YOU IN MINUTES.
WARNING
Running engines produce heat. Severe burns can
DANGER occur on contact.
Combustible material can catch fire on contact.
Rotating parts can entangle hands, feet, hair,
DO NOT touch hot surfaces.
clothing and/or accessories.
Avoid contact with hot exhaust gases.
Traumatic amputation or severe laceration can result. Allow equipment to cool before touching.
Maintain at least 3 ft. (91.4 cm) of clearance on all
Keep hands and feet away from rotating parts. sides to ensure adequate cooling.
Tie up long hair and remove jewelry. Maintain at least 5 ft. (1.5 m) of clearance from
Operate equipment with guards in place. combustible materials.
DO NOT wear loose-fitting clothing, dangling
drawstrings or items that could become caught.
WARNING
WARNING Medical and Life Support Uses.
DANGER WARNING
Fuel and fuel vapours are highly flammable and Rapid retraction of the starter cord will pull hand and
extremely explosive. arm towards the engine faster than you can let go.
Fire or explosion can cause severe burns or death. Unintentional startup can result in entanglement,
Unintentional startup can result in entanglement, traumatic amputation or laceration.
traumatic amputation or laceration. Broken bones, fractures, bruises or sprains could result.
When adding or removing fuel: When starting engine, pull the starter cord slowly
Turn the generator off and let it cool for at least two until resistance is felt and then pull rapidly to avoid
minutes before removing the fuel cap. Loosen the kickback.
cap slowly to relieve pressure in the tank. DO NOT start or stop the engine with electrical
Only fill or drain fuel outdoors in a well-ventilated area. devices plugged in.
DO NOT pump gas directly into the generator at the
gas station. Use an approved container to transfer
the fuel to the generator. CAUTION
DO NOT overfill the fuel tank.
Exceeding the generator’s running capacity can
Always keep fuel away from sparks, open flames,
damage the generator and/or electrical devices
pilot lights, heat and other sources of ignition.
connected to it.
DO NOT light or smoke cigarettes.
When starting the generator: DO NOT overload the generator.
DO NOT attempt to start a damaged generator. Start the generator and allow the engine to stabilize
Make certain that the gas cap, air filter, spark plug, before connecting electrical loads.
fuel lines and exhaust system are properly in place. Connect electrical equipment in the off position,
Allow spilled fuel to evaporate fully before and then turn them on for operation.
attempting to start the engine. Turn electrical equipment off before stopping the
Make certain that the generator is resting firmly on generator.
level ground. DO NOT tamper with the governed speed.
DO NOT modify the generator in any way.
When operating the generator:
DO NOT move or tip the generator during operation.
DO NOT tip the generator or allow fuel or oil to spill.
CAUTION
When transporting or servicing the generator:
Make certain that the fuel shutoff valve is in the off Improper treatment or use of the generator can
position and the fuel tank is empty. damage it, shorten its life and void your warranty.
Disconnect the spark plug wire.
When storing the generator: Use the generator only for intended uses.
Store away from sparks, open flames, pilot lights, Operate only on level surfaces.
heat and other sources of ignition. DO NOT expose generator to excessive moisture,
dust, or dirt.
DO NOT allow any material to block the cooling slots.
If connected devices overheat, turn them off and
WARNING disconnect them from the generator.
DO NOT use the generator if:
Cancer and Reproductive Harm – –– Electrical output is lost
www.P65Warnings.ca.gov –– Equipment sparks, smokes or emits flames
–– Equipment vibrates excessively
4
ENGLISH 100261
Controls and Features
Read this owner’s manual before operating your generator. Familiarize yourself with the location and function of the
464
Generator 637
1 6
637
2 3 4 5 7 8 9
Parts Included
Your 100261 gasoline powered generator ships with the
following parts:
–– Dual 2.4A Port USB Adapter. . . . . . . . . . . . . . . . . 1
–– Oil funnel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
–– Remote. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
5
100261 ENGLISH
Controls and Features
Power Panel
16 12 11
15
14
13 8
1 2
8 10
4 5
6 7 9
D
A
B
C E
PELIGRO
5FM CTLEARANCE
d’octane minimal de 85. Maximum 10 % d'éthanol. Éste es un veneno que no se puede ver ni oler. NUNCA lo use dentro del hogar ni el garaje, INCLUSO SI las puertas y ventanas
'E
están abiertas. Úselo SÓLO a la INTEMPERIE lejos de ventanas, puertas, y orificios de ventilación.
MINIMUM D
Utiliser un générateur à l’intérieur PEUT VOUS TUER EN QUELQUES MINUTES. L’échappement du générateur contient du
.
DANGER monoxyde de carbone. Il s’agit d’un poison que vous ne pouvez ni voir ni sentir. Ne l’utilisez JAMAIS dans la maison ou le garage
1308-L-SF-B
LPN 1032-L-OP Colors MÊME SI les portes et les fenêtres sont ouvertes. Utilisez-le UNIQUEMENT À L’EXTÉRIEUR, loin des fenêtres, portes et trappes
de ventilation.
Rev A
Artwork Notes
Size 204x 46 mm K 485
Revision Changes
--- --- ---
This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for 3mm corner radius; 2mm safe margin; white to be B: Updated size match DF generator
printed shown in 50% process magenta
outside parties without the explicit consent of Champion Power Equipment.
This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for
outside parties without the explicit consent of Champion Power Equipment.
D DANGER E PELIGRO S E
FOR USE IN A WEATHER PROTECTED AREA ONLY - DO NOT EXPOSE TO RAIN
485C
485C
BLACK 179 x 69 mm
PMS 186C
WHITE 127 mm x 71.1 mm
F WARNING ADVERTENCIA
1291-L-SF-A
DO NOT TOUCH! Operation of this equipment may create sparks that can start ¡NO TOCAR! Los gases de La operación de este equipo puede producir chispas que pueden provocar
Exhaust gases, muffler fires around dry vegetation. A spark arrestor may be escape, el silenciador y los incendios alrededor de la vegetación seca. Un supresor de chispas puede que
and engine components required. The operator should contact local fire agencies for compnonentes del motor están sea necesario. El operador debe comunicarse con las agencias locales de
are extremely HOT and laws and regulations relating to fire prevention requirements. extremadamente CALIENTES y bomberos para las leyes y reglamentos relativos a los requisitos de prevención
cause burns. If installed, clean every 100 hours or every season. causan quemaduras. de incendios. Si está instalado, limpie cada 100 horas o cada temporada.
Rev A
This artwork belongs to Champion Power Equipment. The contents are confidential and privileged and shall not be disclosed to or used by or for
outside parties without the explicit consent of Champion Power Equipment.
7
100261 ENGLISH
Controls and Features
Wireless Remote Control
This generator is equipped with a wireless remote
control system for starting and stopping. The system
consists of (4) main components:
1. Receiver Control Module (RCM)
2. Wireless Remote
3. Battery Switch
4. Ignition Switch
The Remote Control functions are enabled when:
1. The Ignition Switch is in the “ON” position, AND
2. The Battery Switch is in the “ON” position.
The Remote Control functions are disabled if either of
the above conditions is not met.
To start the generator by Remote Control, press the
“START” button on the Remote one time. The engine
will attempt to start (6) times. The RCM controls
the Auto Choke during each attempt to start. If the
generator does not start, call Champion Customer Care
team for assistance at 1-877-338-0999.
To stop the generator by Remote Control, press the
“STOP” button on the Remote one time.
8
ENGLISH 100261
Assembly
Your generator requires some assembly. This unit ships Connecting the Battery Cont’d.
from our factory without oil. It must be properly serviced
with fuel and oil before operation. NOTE
If you have any questions regarding the assembly of your
If the battery cables are not visible once the battery
generator, call our help line at 1-877-338-0999. Please maintenance cover has been removed, please note
have your serial number and model number available. that cables may be tucked up above the battery,
not in plain view.
Remove the Generator from the Shipping Carton
1. Set the shipping carton on a solid, flat surface.
2. Remove everything from the carton except the
generator.
3. Using the carrying handles of the unit, carefully
remove the generator from the box. (two people lifting
is recommended)
9
100261 ENGLISH
Assembly
Add Engine Oil Add Engine Oil Cont’d.
NOTE
The recommended oil type is 10W-30 automotive oil.
Degrees Fahrenheitº (Outside)
1. Place the generator on a flat, level surface.
2. Loosen the cover screws and remove the
maintenance cover.
CAUTION
The engine is equipped with a low oil shut-off and will
stop when the oil level in the crankcase falls below the
threshold level.
NOTE
The generator rotor has a sealed, pre-lubricated ball
bearing that requires no additional lubrication for the life
of the bearing.
NOTE
We consider the first 5 hours of run time to be the break-
NOTE in period for the unit. During the break in period stay at
or below 50% of the running watt rating and vary the
Once oil has been added, a visual check should show oil load occasionally to allow stator windings to heat and
about 1-2 threads from running out of the fill hole. cool. Adjusting the load will also cause engine speed to
If using the dipstick to check oil level, DO NOT screw in vary and help seat piston rings. After the 5 hour break-in
the dipstick while checking. period, change the oil.
NOTE NOTE
Check oil often during the break-in period. Refer to the Synthetic oil may be used after the 5 hour initial break-
Maintenance section for recommended service intervals. in period. Using synthetic oil does not increase the
recommended oil change interval.
3. Remove oil fill cap/dipstick to add oil.
4. Add up to 0.6 L (0.6 qt.) of oil and replace oil fill
cap/dipstick. DO NOT OVERFILL. NOTE
5. Check engine oil level daily and add as needed. Weather will affect engine oil and engine performance.
Change the type of engine oil used based on weather
conditions to suit the engine needs.
10
ENGLISH 100261
Assembly
Add Fuel Add Fuel Cont’d.
1. Use clean, fresh, regular unleaded fuel with a
minimum octane rating of 85 and an ethanol NOTE
content of less than 10% by volume. Our engines work well with 10% or less ethanol
2. DO NOT mix oil with fuel. blend fuels. When using blended fuels there are
3. Clean the area around the fuel cap. some issues worth noting:
4. Remove the fuel cap. –– Ethanol-gasoline blends can absorb more water
5. Slowly add fuel to the tank. DO NOT OVERFILL. than gasoline alone.
Fuel can expand after filling. A minimum of –– These blends can eventually separate, leaving
1/4 in. (6.4 mm) of space left in the tank is required water or a watery goo in the tank, fuel valve and
for fuel expansion, more than 1/4 in. (6.4 mm) is carburetor.
recommended. Fuel can be forced out of the tank as a –– With gravity-fed fuel supplies, this compromised
result of expansion if it is overfilled, and can affect the fuel can be drawn into the carburetor and cause
stable running condition of the product. When filling damage to the engine and/or potential hazards.
the tank, it is recommended to leave enough space for –– There are only a few suppliers of fuel stabilizer
the fuel to expand. that are formulated to work with ethanol blend
6. Screw on the fuel cap and wipe away any spilled fuels.
fuel. –– Any damages or hazards caused by using
improper fuel, improperly stored fuel, and/
CAUTION or improperly formulated stabilizers, are not
covered by manufacture’s warranty.
Use regular unleaded gasoline with a minimum
octane rating of 85. It is advisable to always shut off the fuel supply,
run the engine to fuel starvation and drain the tank
Do not mix oil and gasoline.
when the equipment is not in use for more than 30
Fill tank to approximately 1/4 in. (6.4 mm) below
days.
the top of the tank to allow for fuel expansion.
DO NOT pump gas directly into the generator at the
gas station. Use an approved container to transfer Grounding
the fuel to the generator. Your generator must be properly connected to an
DO NOT fill fuel tank indoors. appropriate ground to help prevent electric shock.
DO NOT fill fuel tank when the engine is running or hot.
DO NOT overfill the fuel tank. WARNING
DO NOT light cigarettes or smoke when filling the
fuel tank. Failure to properly ground the generator can result
in electric shock.
11
100261 ENGLISH
Operation
Generator Location Grounding
NEVER operate the generator inside any building, The generator system ground connects the frame to the
including garages, basements, crawlspaces and sheds, ground terminals on the power panel.
enclosure or compartment, including the generator –– The generator (stator winding) is isolated from the
compartment of a recreational vehicle. Please consult frame and from the AC receptacle ground pin.
your local authority. In some areas, generators must –– Electrical devices that require a grounded receptacle
be registered with the local utility. Generators used at pin connection will not function if the receptacle ground
construction sites may be subject to additional rules and pin is not functional, unless the neutral wire is bonded
regulations. Generators should be on a flat, level surface to the frame.
at all times (even while not in operation). Generators
must have at least 5 ft. (1.5 m) of clearance from all Wireless Remote Start
combustible material. In addition to clearance from all Wireless remote starting is only possible within 80 feet
combustible material, generators must also have at least of the generator. (Wireless signal may not pass through
3 ft. (91.4 cm) of clearance on all sides to allow for some solid objects.)
adequate cooling, maintenance and servicing. Generators Do not attempt to adjust the carburetor choke. The
should never be started or operated in the back of a remote and electric system will automatically close and
SUV, camper, trailer, in the bed of a truck (regular, flat open the choke.
or otherwise), under staircases/stairwells, next to walls 1. Make certain the generator is on a flat, level
or buildings, or in any other location that will not allow surface.
for adequate cooling of the generator and/or the muffler. 2. Turn off all electrical loads connected to the
DO NOT contain generators during operation. Allow generator. Never start or stop the generator with
generators to properly cool before transport or storage. electrical devices turned on.
Place the generator in a well-ventilated area. DO NOT 3. Turn the Fuel Valve to the “ON” position.
place the generator near vents or intakes where exhaust 4. Press the Battery Switch to “ON”.
fumes could be drawn into occupied or confined spaces. 5. Press the Ignition Switch to “ON”.
Carefully consider wind and air currents when positioning 6. WIRELESS REMOTE START: press and release the
generator. “START” button on the handheld Remote Control
Failure to follow proper safety precautions may void device. DO NOT hold the button down, only press
manufacturer’s warranty. the button once. The engine will attempt to start six
times.
WARNING 7. If the generator fails to start, check the battery
condition and cable connections.
Do not operate or store the generator in rain, snow,
or wet weather.
NOTE
Using a generator or electrical appliance in wet The supplied 12V 7AH battery does re-charge while the
conditions, such as rain or snow, or near a pool or engine is running, but it is also recommended that the
sprinkler system, or when your hands are wet, could battery be fully charged at least once per month.
result in electrocution.
NOTE
WARNING When the battery switch is in the “ON” position, the
During operation the muffler and exhaust fumes switch will light up if the battery is sending out a
charge. If the switch does not light up while in the “ON”
produced will become hot. If adequate cooling and
position, check that the battery connection is still good.
breathing space are not supplied, or if the generator
is blocked or contained, temperatures can become
extremely heated and may lead to fire.
12
ENGLISH 100261
Operation
Electric and Recoil Start Electric and Recoil Start Cont’d.
1. Make certain the generator is on a flat, level surface. within five seconds, release the switch and wait at
2. Disconnect all electrical loads from the generator. least ten seconds before attempting to start the
Never start or stop the generator with electrical engine again.
devices plugged in or turned on. 8. RECOIL START: Pull the starter cord slowly until
3. Turn the fuel valve to the “On” position. resistance is felt and then pull rapidly.
9. As engine warms up, push the choke button to the
“Run” position.
NOTE
Keep choke button in “Choke” position for only 1
pull of the recoil starter. After first pull, push choke
button to the “Run” position for up to the next 3
pulls of the recoil starter. Too much choke leads to
spark plug fouling/engine flooding due to the lack of
4. Turn the battery switch to the “On” position. incoming air. This will cause the engine not to start.
NOTE
If the engine starts but does not continue to run
make certain that the generator is on a flat, level
surface. The engine is equipped with a low oil
sensor that will prevent the engine from running
when the oil level falls below a critical threshold.
13
100261 ENGLISH
Operation
Manual Choke Start Manual Choke Start Cont’d.
If the battery is dead or not able to produce enough
current to power the push button choke, the choke itself NOTE
can be operated manually to help start the engine. To Keep choke lever in “Choke” (right) position for only
manually choke and start the inverter, follow these steps: 1 pull of the recoil starter. After first pull, move the
choke lever to the “Run” (left) position for up to the
1. Loosen the screws and remove the maintenance
next 3 pulls of the recoil starter. Too much choke
cover. (A)
leads to spark plug fouling/engine flooding due to
the lack of incoming air. This will cause the engine
A not to start.
WARNING
For periods of high electrical load or momentary
fluctuations, the Economy Control Switch should be
B turned OFF.
14
ENGLISH 100261
Operation
Connecting Electrical Loads 12V DC Outlet
1. Let the engine stabilize and warm up for a few The 12V DC outlet can be used with the supplied
minutes after starting USB charger and other commercially available 12V DC
2. Plug in and turn on the desired 120 Volt AC single automotive style plugs. The DC output is unregulated
phase, 60 Hz electrical loads. and can damage some products. Confirm your accessory
–– DO NOT connect 3-phase loads to the generator. input voltage range is at least 12-24V DC. When using
–– DO NOT connect 50 Hz loads to the generator. the DC outlet turn the Economy mode switch to the
–– DO NOT overload the generator. “OFF” position.
NOTE WARNING
Connecting a generator to your electric utility Do not operate a device while it is plugged in to the 12V
company’s power lines or to another power source DC outlet.
may be against the law. In addition this action,
Prolonged exposure to engine exhaust can cause serious
if done incorrectly, could damage your generator
injury or death.
and appliances and could cause serious injury or
even death to you or a utility worker who may be
working on nearby power lines. If you plan to run a
portable electric generator during an outage, please
WARNING
notify your electric utility company immediately While charging a device do not place on the exhaust side
and remember to plug your appliances directly of the generator. Extreme heat caused by exhaust can
into the generator. Do not plug the generator into damage the device, and cause a potential fire hazard.
any electric outlet in your home. Doing so could
create a connection to the utility company power
lines. You are responsible for ensuring that your Stopping the Engine
generator’s electricity does not feed back into the 1. Turn off and unplug all electrical loads. Never start
electric utility power lines. or stop the generator with electrical devices plugged
If the generator will be connected to a building in or turned on.
electrical system, consult your local utility company 2. Let the generator run at no-load for several minutes
or a qualified electrician. Connections must isolate to stabilize internal temperatures of the engine and
generator power from utility power and must comply generator.
with all applicable laws and codes. 3. Turn the fuel valve to the “OFF” position.
4. Let the engine run until fuel starvation has stopped
the engine. This usually takes a few minutes.
5. Turn the ignition switch to the “OFF” position.
6. Turn the battery switch to “OFF” position if
applicable.
Important: Always ensure that the Fuel Valve and the
ignition switch and battery switch are in the “OFF”
position when the engine is not in use.
NOTE
If the engine will not be used for a period of two (2)
weeks or longer, please see the storage section for proper
engine and fuel storage.
NOTE
Always turn the battery switch to the “OFF”
position when unit is not in use, this will stop the
battery from being drained. Follow the maintenance
and storage instructions for the generator and
battery when the unit will not be used for a period
of 2 weeks or more.
15
100261 ENGLISH
Operation
Do Not Overload Generator Operation at High Altitude
Capacity The density of air at high altitude is lower than at sea
level. Engine power is reduced as the air mass and air-
Follow these simple steps to calculate the running and
fuel ratio decrease. Engine power and generator output
starting watts necessary for your purposes.
will be reduced approximately 3½% for every 1000
1. Select the electrical devices you plan on running at
feet of elevation above sea level. This is a natural trend
the same time.
and cannot be changed by adjusting the engine. At high
2. Total the running watts of these items. This is
altitudes increased exhaust emissions can also result
the amount of power you need to keep your items
due to the increased enrichment of the air fuel ratio.
running.
Other high altitude issues can include hard starting,
3. Identify the highest starting wattage of all devices
increased fuel consumption and spark plug fouling.
identified in step 1. Add this number to the number
To alleviate high altitude issues other than the natural
calculated in step 2. Surge wattage is the extra
power loss, Champion Power Equipment can provide a
burst of power needed to start some electric driven
high altitude carburetor main jet. The alternative main
equipment. Following the steps listed under “Power
jet and installation instructions can be obtained by
Management” will guarantee that only one device
contacting Customer Support. Installation instructions
will be starting at a time.
are also available in the Technical Bulletin area of the
Power Management Champion Power Equipment internet site.
Use the following formula to convert voltage and The part number and recommended minimum altitude
amperage to watts: for the application of the high altitude carburetor main
Volts x Amps = Watts jet is listed in the table below.
In order to select the correct high altitude main jet
To prolong the life of your generator and attached
it is necessary to identify the carburetor model. For
devices, follow these steps to add electrical load:
this purpose, a code is stamped on the side of the
1. Start the generator with no electrical load attached.
carburetor. Select the correct main jet part number
2. Allow the engine to run for several minutes to
corresponding to the carburetor code found on your
stabilize.
particular carburetor.
3. Plug in and turn on the first item. It is best to
attach the item with the largest load first. Carburetor Main Jet Part Number Altitude
Code
4. Allow the engine to stabilize.
Standard 28.131017.00.H 3500 Feet
5. Plug in and turn on the next item. P25-10-H
Altitude 28.131017.00.01.H (1067 Meters)
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.
NOTE WARNING
Never exceed the specified capacity when adding
loads to the generator. Operation using the alternative main jet at elevations
lower than the recommended minimum altitude can
damage the engine. For operation at lower elevations, the
standard main jet must be used. Operating the engine
Overload Operation with the wrong engine configuration at a given altitude
may increase its emissions and decrease fuel efficiency
The overload indicator light will turn on when the rated
and performance.
load is exceeded. When the maximum load is reached,
the LED will blink and cut power to the receptacles. To
recover the power, shut down the engine, wait until the
light turns off and restart the generator.
16
ENGLISH 100261
Operation
Wireless Set Button Parallel Operation
The wireless set button is a feature that lets the user Two (2) Champion model 100261 generators can
sync remotes to the generator. One can set up to two be operated in parallel to increase the total available
remote controls or reset a remote control with the electrical power. A Champion parallel kit (optional
generator. To reset a remote control or sync two remote equipment) is required for parallel operation. For kit
controls follow these steps:
availability, call customer service at 1-877-338-0999 or
1. Turn the ignition switch to the “ON” position.
visit www.championpowerequipment.com.
2. Turn the battery switch to the “ON” position.
3. Push and hold the wireless set button next to
the red light (located on the front panel) for Detailed instructions for parallel kit installation, operation,
approximately three seconds; the red light will turn and rating of the connected generators are provided in the
on. parallel kit owner’s manual and operating instructions.
4. Push and release the “STOP” button on the remote.
The red light blinks once to erase the remote
program.
5. Push and release the START button. The red light
blinks once to program the remote.
6. Push and hold the programming button
approximately three seconds until the red light turns
off.
7. Test Start & Stop features
NOTE
Only two remote controls can be in sync with one
generator at a time.
NOTE
Changing a remote control battery may not require
the user to reset the remote control.
17
100261 ENGLISH
Maintenance and Storage
The owner/operator is responsible for all periodic Oil Cont’d.
maintenance.
WARNING NOTE
Once oil has been added, a visual check should show
Never operate a damaged or defective generator. oil about 1-2 threads from running out of the fill hole.
If using the dipstick to check oil level, DO NOT screw
in the dipstick while checking.
WARNING
Tampering with the factory set governor will void
your warranty.
WARNING
Improper maintenance will void your warranty.
Oil
Change oil when the engine is warm. Refer to the oil 5. Refer to the spark plug recommendation chart when
specification to select the proper grade of oil for your replacing the plug.
operating environment. 6. Carefully thread the plug into the engine.
1. Remove oil fill cap/dipstick. 7. Use the spark plug socket (not included) to firmly
2. Use pliers to slide the spring clamp down the oil install the plug.
drain hose and pull the hose off the plug bracket. 8. Attach the spark plug wire to the plug.
3. Point the hose into a drain pan and allow the oil to
drain completely. Note: The hose end must be lower
than the engine base to allow the oil to drain.
4. Replace oil drain hose onto plug bracket and slide
spring clamp back into position.
5. Add up to 0.6 qt. (0.6 L) of oil and replace oil fill
cap/dipstick. DO NOT OVERFILL.
6. Dispose of used oil at an approved waste
management facility.
18
ENGLISH 100261
Maintenance and Storage
Air Filter Adjustments
1. Remove the maintenance cover. The air-fuel mixture is not adjustable. Tampering with
2. Locate the air filter plastic cover. the governor can damage your generator and your
3. Unsnap the locking hinge on the cover. electrical devices and will void your warranty. CPE
4. Remove the old filter. recommends that you contact our service line at
5. Place the new filter in the assembly. 1-877-338-0999 for all other service and/or adjustment
6. Re-snap the hinge on the air filter cover. needs.
7. Reinstall the maintenance cover and tighten the
cover screw securely. Maintenance Schedule
Follow the service intervals indicated in the following
Cleaning maintenance schedule.
Service your generator more frequently when operating
CAUTION in adverse conditions.
Contact our help line at 1-877-338-0999 to locate the
DO NOT spray generator with water. nearest Champion Power Equipment certified service
dealer for your generator or engine maintenance needs.
Water can contaminate the fuel system. Every 8 hours or daily
Check oil level
Use a damp cloth to clean exterior surfaces of the Clean around air intake and muffler
generator. First 5 hours
Use a soft bristle brush to remove dirt and oil. Change oil
Use an air compressor (25 PSI) to clear dirt and debris
Every 50 hours or every season
from the generator. Clean air filter
Generator Battery
This product is equipped with an automatic battery
charging circuit. The battery will receive charging
voltage when the engine is running. The battery will
maintain a proper charge if the unit is used on a regular
basis (about once every two weeks). If it is used less
frequently, the battery should be connected to a trickle
charger (not included) or battery maintainer to keep the
CAUTION battery properly charged. If the battery is not able to
Failure to clean the spark arrester will result in start the engine, it can be started by manually pulling
degraded engine performance. the engine recoil cord. If the battery voltage is extremely
low, the charging circuit may not be able to re-charge
the battery. In this case, the battery must be connected
to a standard automotive style battery charger for re-
charging before it can be used.
19
100261 ENGLISH
Maintenance and Storage
Charge the Battery Generator Maintenance Cont’d.
For a generator equipped with batteries for electric Use a damp cloth to clean exterior surfaces of the generator.
starting, proper battery maintenance and storage should Use a soft bristle brush to remove dirt and oil.
be followed. An automatic battery charger (not included) Use an air compressor (25 PSI) to clear dirt and debris
with automatic charging capability should be used to from the generator.
charge the battery. Maximum charging rate should not Inspect all air vents and cooling slots to ensure that they
exceed 1.5 amps. Follow the instructions included with are clean and unobstructed.
the battery charger. The battery should be fully charged
at least once per month.
Storage
NOTE The generator should be started at least once every 14
days and allowed to run for at least 20 minutes. For
A Float Charger will maintain the battery condition longer term storage, please follow these guidelines.
over long storage periods.
Generator Storage
Disconnect the Battery 1. Add a properly formulated fuel stabilizer to the tank.
1. Remove the battery panel cover. 2. Be sure all appliances are disconnected from the
2. Remove the protective cover from the black/negative generator.
battery lead. 3. Run the generator for a few minutes so the treated
3. Disconnect the black/negative lead from the black/ fuel cycles through the fuel system and carburetor.
negative terminal on the battery and store the cap 4. Turn the fuel valve to the “Off” position.
screw and nut. 5. Let the generator run until fuel starvation has
4. Repeat steps 1-2 for the red/positive battery lead. stopped the engine. This usually takes a few
5. Store the battery in a cool, dry place. minutes.
6. The generator needs to cool completely before
cleaning and storage.
Remote Control Battery
7. Remove the spark plug cap, then pull the recoil grip 3
times to drain the gasoline from the carburetor jets.
NOTE 8. Change the engine oil.
–– Always purchase the correct size and grade of 9. Remove the spark plug and pour about a tablespoon
battery most suitable for the intended use. of oil into the cylinder. Crank the engine slowly to
–– Clean the battery contacts and also those of the distribute the oil and lubricate the cylinder.
device prior to battery installation. 10. Reattach the spark plug.
–– Remove batteries from equipment which is not to 11. Store the unit in a clean, dry place out of direct
be used for an extended period of time. sunlight.
–– Remove batteries if consumed or if product is to
be left unused for a long time.
DANGER
Generator exhaust contains odorless and colorless carbon
Generator Maintenance monoxide gas.
Make certain that the generator is kept clean and stored To avoid accidental or unintended ignition of your remote
properly. Only operate the unit on a flat, level surface in start generator during periods of storage, the following
a clean, dry operating environment. DO NOT expose the precautions should be followed:
unit to extreme conditions, excessive dust, dirt, moisture –– When storing the generator for short periods of
or corrosive vapours. time make sure that the Ignition Switch, the Fuel
Valve and the Battery Switch are set in the OFF
CAUTION position.
–– When storing the generator for extended periods of
time make sure that the Ignition Switch, the Fuel
DO NOT use a garden hose to clean the generator.
Valve and the Battery Switch are set in the the
Water can enter the generator through the cooling the OFF position and the battery leads have been
slots and damage the generator windings. disconnected from the battery.
20
ENGLISH 100261
Specifications
Oil
Use 10W-30 automotive oil.
Oil capacity is up to 0.6 L (0.6 qt.).
DO NOT OVERFILL
Please reference the following chart for recommended
oil types for use in the generator.
NOTE
Weather will affect engine oil and engine
performance. Change the type of engine oil used
based on weather conditions to suit the engine
needs.
21
22
Specifications
OUTPUT PANEL
G
G
DC DIODE 8A, C.B. DC12V
G
R R + _
20A, C.B.
R
G C
B 30A, C.B. R
W
G R CHARGER
TT-30R SWITCH CHOKE.SW
W/G
DC COIL G
B
5-20R
R
lb l la
W/G R W +
G/Y
G/Y G/Y G/Y G/Y
PARALLEL EARTH
TERMINAL W
W TERMINAL R
R R
R Br W
W Red Black G/Y
W
W R
W/G
R
AC COIL R ECO.SW STOP.SW
R Y
CONTROL UNIT B 3 ST
6
Y W/L 2ON
G/Y
5
Y B/W 4
1OFF
O
O BUTTON
PORTFIRE
W/L
- +
W Br L B
SUB COIL
C
B B PILOT
BGY G/Y O B/W C W W C
OYL C LAMP
O W
C
W/G
B G/Y
GENERATOR B/W C
G
W Br R
ENGINE Y FUSE B/W G/Y
COMBINATION SWITCH R 10A
B
B/W W
1 2 3 4 5 6 antenna Receiver module
B
OFF
M Y
Wiring Diagram
ON W/G W/G
100261 ENGLISH
B/G
ST B R
Y
O
B BLACK Br BROWN L
Y YELLOW B/W BLACK WHITE STEPPING MOTOR SPARK PLUG TCI UNIT OIL LEVEL SW BATTERY STARTER C
B/G
L BLUE W/G WHITE GREEN (THROTTLE)
G GREEN G/Y GREEN YELLOW N.C. FUEL CUT
R RED W/L WHITE BLUE SOLENOID STEPPING MOTOR (CHOKE)
W WHITE O ORANGE
C CARNATIONA AMETHYST
23
13 14 15 19 20 21 22 23 24 25
9 18
1 2 3 4 5 6 7 8 26
Parts Diagram
17 27
12
28
9 10 11
16 29
Specifications
30
31
32 2
33
99 34
35
100 36
101 68 37
102 38
69
103 9 39
104 94 93 92
105
95 69 40
106
96
107 70 4
97
95 41 54
98 71
108 36 42 53
67
109 66 43 52
138 72 51
139 65 50
20 140 49
141 137 73 64 48
142 47
143 63 35
144 136 74 62 46
145 35 4
146 135 45
147 75 61
134 44
148 37
133
132 42 60
149 131
150 130 76
151 129
152 128 118 16 77
153 127 117
126 116 69
125 115
114 119 78
43
36
113 55
112 120 121 85 56
111 84 86 57
11 35 87
110 122 83 88 58
82 11
42 81 89 59
43 80 90
79
123 91
4
124
154 155
ENGLISH 100261
100261 ENGLISH Parts List
24
ENGLISH 100261
Specifications
25
100261 ENGLISH
Specifications
This page intentionally left blank.
26
27
111
65 69 72 74 75 94 103
62
17 18 19 95
61 16 20
15 96
14 21
97
60 63 13 22
66 70 98
12 23 48
99
5 24 100
Specifications
104
Engine Parts Diagram
11 101
106
10 102
9 27 105
28
25
8 33 26
34
29 34
35
36
7 37
38
39
40
41
42 30
43
44
45 31
46 32
47
48
49 107
50
51
52
6 53
5
4
56 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78
3
55
57
54
79
109
2
110
5
1
93 92 91 90 89 88 87 86 85 84 83 82 81 80 108
ENGLISH 100261
100261 ENGLISH Engine Parts List
# Part Number Description Qty # Part Number Description Qty
1 1.5789.0835 Flange Bolt M8 x 35 6 55 83.080014.01.01 Air Guide Board 1
2 2.11.014 Oil Seal 2 56 2.03.016 Washer Ø10 x Ø16 x 1.5, Drain Bolt 1
3 83.030007.01 Cover, Crankcase 1 57 83.032000.00 Hose, Oil Drain 1
4 83.127000.01 Oil Level Sensor 1 58 28.030009.00 Gasket, Cylinder Head 1
5 1.5789.0612 Flange Bolt M6 x 12 11 59 2.04.003 Dowel Pin, Ø10 x 14 2
6 83.030010.01 Plate, Coil 1 60 83.040006.01 Valve, Exhaust 1
7 83.120100.02 Flywheel 1 61 83.040002.01 Valve, Intake 1
8 83.080001.01 Cooling Fan 1 62 2.01.017 Stud Bolt M6 x 32 2
9 83.060001.01 Pulley, Starter 1 63 28.010100.00 Cylinder Head 1
10 2.02.006 Flange Nut M14 x 1.5 1 64 2.15.002 Spark Plug F6RTC 1
11 83.080100.01.2 Fan Cover 1 65 83.040017.01 Oil Seal, Valve 1
12 45.060008.00 Screw, Ratchet Guide 1 66 83.040004.01 Guide Plate, Push Rod 1
13 45.060007.00 Ratchet Guide 1 67 1.5789.0865 Flange Bolt M8 x 65 2
14 45.060009.00 Spring, Ratchet Guide 1 68 1.5789.0850 Flange Bolt M8 x 50 2
15 45.060002.00 Starter Ratchet, Iron 2 69 2.01.020 Stud Bolt M6 x 97 2
16 45.060003.00 Spring, Ratchet 2 70 83.040010.01 Bolt, Rocker Arm 2
17 21.061001.01 Reel, Recoil Starter 1 71 83.040005.01 Push Rod 2
18 21.061005.00 Spring, Recoil Starter 1 72 83.040003.01 Spring, Valve 2
19 81.061010.01 Holder, Rope 1 73 83.040009.01 Rocker Arm, Valve 2
20 81.061006.00 Grip, Rubber 1 74 83.040001.01 Retainer, Valve Spring 2
21 2.10.001.1 Rope, Ø4 x 1570, Black 1 75 83.040014.01 Valve Collet 2
22 2.05.050 Clamp, 100 mm, Wire 1 76 21.040020.00 Adjusting Nut, Valve 2
23 83.061100.01.2 Cover, Recoil Starter 1 77 21.040021.00 Nut, Lock 2
24 1.5789.0608 Flange Bolt M6 x 8 3 78 83.080200.01 Air Shroud, Cylinder 1
25 83.091200.01 Cover, Air Cleaner 1 79 23.020001.01 Breather Tube 1
26 83.091300.01 Element, Air Cleaner 1 80 83.021101.01 Cover, Cylinder Head 1
27 1.6177.1.06 Flange Nut M6 2 81 83.021001.01 Gasket, Cylinder Head Element 1
28 83.090001.01 Flange, Steel 1 82 83.021200.01 Element Component, Head Cover 1
29 83.091100.01 Base, Air Cleaner 1 83 83.020002.01 Gasket, Cylinder Head Cover 1
30 83.091006.01 Buckle 1 84 28.050301.00 Ring, First Piston 1
31 83.091002.02 Seal 1 85 28.050302.00 Ring, Second Piston 1
32 83.090004.01 Pipe, Air Cleaner 1 86 28.050303.00 Ring, Oil 1
33 83.130004.01 Gasket, Air Cleaner 1 87 2.09.002 Circlip Ø16 x Ø1 2
28.131000.01 88 28.050005.00 Piston 1
S/N < 18MAY0700437 89 83.050003.01 Wrist Pin 1
34 Carburetor Assembly 1
28.131000.04 90 83.050200.01 Connecting Rod Assembly 1
S/N 18MAY0700437 + 91 83.040100.01 Camshaft 1
35 83.130001.01 Insulator, Carburetor 1 92 83.031000.01 Oil Dipstick Assembly 1
36 83.130002.01 Gasket, Insulator 2 93 83.030035.01 Oil Nipple 1
37 1.5789.0620 Flange Bolt M6 x 20 2 94 1.9074.1.0408 Screw/Washer Assembly M4 x 8 2
38 28.123000.00 Ignition Coil 1 95 45.132200.01 Stepper Motor, Choke Valve 1
39 28.030100.01 Crankcase 1 96 81.132200.00 Stepper Motor, Throttle Valve 1
40 83.040013.01 Lifter, Valve 2 97 83.132100.01 Stepper Motor Base 1
41 83.030013.01 Seal Strip, Crankcase Cover 2 98 83.130005.02 Support, Stepper Motor 1
42 2.04.002 Dawl Pin 8 x 14 2 99 1.819.0508 Screw M5 x 8 1
43 1.276.6205 Bearing 6205 2 100 81.130008.00 Connecter, Throttle Valve Axis 1
44 2.14.017 Woodruff Key 4 x 6.5 x 16 1 101 81.130010.00 Spring, Connecter 1
45 83.125100.01 Starter Motor 1 102 28.131000.04 Carburetor 1
Plastic Corrugated Pipe, 103 1.818.0306 Screw M3 x 6 4
46 5.1320.010 1
Ø6.8 x Ø10 x 100
104 83.130008.01 Connecter, Choke Valve Axis 1
47 5.1900.065 Red Wire, 130mm 1
28.131017.00 Main Jet, Standard 1
48 1.9074.3.0508 Screw M5 x 8 3 105
28.131017.00.01 Main Jet, Altitude /
49 152.200013.01 Sheath, Rubber 2
106 83.061000.01 Recoil Assembly 1
50 83.050100.01 Crankshaft 1
107 83.091000.01 Air Cleaner Assembly 1
51 83.125200.01 Relay, Starter 1
108 83.021000.01 Cylinder Head Cover Assembly 1
52 1.5789.0615 Flange Bolt M6 x 15 1
109 2.06.013 Clamp, Ø13.5 × b10 1
53 83.030008.01 Gasket, Crankcase Cover 1
110 45.030200.00 Support 1
54 1.9074.4.0510 Screw/Washer Assembly M5 x 10 4
111 28.010000.00 Cylinder Head Assembly 1
28
ENGLISH 100261
Troubleshooting
Problem Cause Solution
Generator will not start No fuel Add fuel
Faulty spark plug Replace spark plug
Unit loaded during start up Remove load from unit
Generator will not start; Low oil level Fill crankcase to the proper level
Generator starts but runs roughly Place generator on a flat, level surface
Choke in the wrong position Adjust choke
Spark plug wire loose Attach wire to spark plug
Generator will not start wirelessly Remote control battery is dead Replace remote control battery
Generator battery is dead Recharge generator battery
Battery switch is in the “OFF” position Turn battery switch to “ON” position
Generator will not start electrically Generator battery is dead Recharge generator battery
Battery switch is in the “OFF” position Turn battery switch to “ON” position
Generator shuts down during operation Out of fuel Fill fuel tank
Low oil level Fill crankcase to the proper level. Place
generator on a flat, level surface
Generator cannot supply enough power or Generator is overloaded Review load and adjust. See “Power
overheating Management”
Insufficient ventilation Check for air restriction. Move to a well
ventilated area
No AC output Cable not properly connected Check all connections
Connected device is defective Replace defective device
Circuit breaker is open Reset circuit breaker
Loose wiring Inspect and tighten wiring connections
Other Contact the help line
Repeated circuit breaker tripping Overload Review load and adjust. See “Power
Management”
Faulty cords or device Check for damaged, bare or frayed wires.
Replace defective device
29
WARRANTY* Other Exclusions
CHAMPION POWER EQUIPMENT This warranty excludes:
3 YEAR LIMITED WARRANTY – Cosmetic defects such as paint, decals, etc.
– Wear items such as filter elements, o-rings, etc.
Warranty Qualifications – Accessory parts such as starting batteries, and storage
To register your product for warranty and FREE lifetime call center covers.
technical support please visit:
https://www.championpowerequipment.com/register – Failures due to acts of God and other force majeure events
beyond the manufacturer’s control.
To complete registration you will need to include a copy of the
purchase receipt as proof of original purchase. Proof of purchase – Problems caused by parts that are not original Champion
is required for warranty service. Please register within ten (10) Power Equipment parts.
days from date of purchase. When applicable, this warranty does not apply to products used
for prime power in place of a utility.
Repair/Replacement Warranty
CPE warrants to the original purchaser that the mechanical and Limits of Implied Warranty and
electrical components will be free of defects in material and Consequential Damage
workmanship for a period of three years (parts and labor) from
Champion Power Equipment disclaims any obligation to cover
the original date of purchase and 270 days (parts and labor) for
any loss of time, use of this product, freight, or any incidental
commercial and industrial use. Transportation charges on product
or consequential claim by anyone from using this product.
submitted for repair or replacement under this warranty are the
THIS WARRANTY AND THE ATTACHED U.S. EPA and/or CARB
sole responsibility of the purchaser. This warranty only applies to
EMISSION CONTROL SYSTEM WARRANTIES (WHEN APPLICABLE)
the original purchaser and is not transferable.
ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS
Do Not Return The Unit To The Place Of FOR A PARTICULAR PURPOSE.
Purchase A unit provided as an exchange will be subject to the warranty
Contact CPE’s Technical Service and CPE will troubleshoot any of the original unit. The length of the warranty governing the
issue via phone or e-mail. If the problem is not corrected by exchanged unit will remain calculated by reference to the purchase
this method, CPE will, at its option, authorize evaluation, repair date of the original unit.
or replacement of the defective part or component at a CPE This warranty gives you certain legal rights which may change
Service Center. CPE will provide you with a case number for from state to state or province to province. Your state or province
warranty service. Please keep it for future reference. Repairs or may also have other rights you may be entitled to that are not
replacements without prior authorization, or at an unauthorized listed within this warranty.
repair facility, will not be covered by this warranty.
Contact Information
Warranty Exclusions Address
This warranty does not cover the following repairs and equipment:
Champion Power Equipment, Inc.
Normal Wear 12039 Smith Ave.
Products with mechanical and electrical components need Santa Fe Springs, CA 90670 USA
periodic parts and service to perform well. This warranty does not www.championpowerequipment.com
cover repair when normal use has exhausted the life of a part or Customer Service
the equipment as a whole.
Mon – Fri 8:30 AM – 5:00 PM (PST/PDT)
Installation, Use and Maintenance Toll Free: 1-877-338-0999
This warranty will not apply to parts and/or labor if the product is info@championpowerequipment.com
deemed to have been misused, neglected, involved in an accident, Fax no.: 1-562-236-9429
abused, loaded beyond the product’s limits, modified, installed Technical Service
improperly or connected incorrectly to any electrical component.
Mon – Fri 8:30 AM – 5:00 PM (PST/PDT)
Normal maintenance is not covered by this warranty and is not
Toll Free: 1-877-338-0999
required to be performed at a facility or by a person authorized by
tech@championpowerequipment.com
CPE.
24/7 Tech Support: 1-562-204-1188
*Except as otherwise stipulated in any of the following enclosed Emission Control System Warranties (when applicable) for the Emission Control System: U.S. Environment Protection Agency
(EPA) and/or California Air Resources Board (CARB). Whichever warranty applies for the longer period, either this 3 year limited warranty or the applicable Emission Control System Warranty,
shall supersede the other.
CHAMPION POWER EQUIPMENT, INC. (CPE),
THE UNITED STATES ENVIRONMENT PROTECTION AGENCY (U.S. EPA)
AND THE CALIFORNIA AIR RESOURCES BOARD (CARB) EMISSION CONTROL SYSTEM WARRANTY
Your Champion Power Equipment (CPE) engine complies with both the U.S. EPA and state of California Air Resources Board
(CARB) Exhaust and Evaporative emissions regulations.