Professional Documents
Culture Documents
Feature Description
Disclaimer
The contents of this document are subject to revision without notice due to
continued progress in methodology, design and manufacturing. Ericsson shall
have no liability for any error or damage of any kind resulting from the use of this
document.
Trademark List
All trademarks mentioned herein are the property of their respective owners.
These are shown in the document Trademark Information.
Contents
3 Feature Operation 4
3.1 Automated Cell Capacity Estimation Operation 4
3.2 Cell Capacity Assessment 4
3.3 Automated Cell Capacity Estimation Process 5
3.4 Configuration Guidelines 8
4 Parameters 11
4.1 Introduced Parameters 11
4.2 Affected Parameters 11
4.3 Parameters Affecting the Feature 12
5 Network Impact 13
6 Performance 14
6.1 KPIs 14
6.2 Counters 14
6.3 Events 14
Summary
The purpose of Automated Cell Capacity Estimation is to automatically and
periodically perform estimations of the downlink capacity in order to serve the
load management features with valid estimates for the selected cells.
The feature introduces a method for the estimation of the current capacity of the
downlink of each cell, which is used by load management features to assess the
traffic load. Periodic estimations are performed on the current cell capacity to
ensure it is reliable.
Note: If a fixed cell capacity value was set manually, it is likely that after
cell capacity changes, the previous configuration does not reflect
actual cell capacity value.
— The cell capacity value is more accurate over time than the fixed predefined
value.
Additional Information
More information about this feature and related topics can be found in the
following documentation:
— Inter-Frequency Offload
Hardware
No specific hardware requirement is expected for this feature.
Limitations
No limitations for this feature.
Network Requirements
At feature activation, a license key must be activated to operate the Automated
Cell Capacity Estimation feature.
System Functions
This feature does not affect any system functions.
3 Feature Operation
This section describes the Automated Cell Capacity Estimation feature in more
detail, including network configuration requirements and operation flows.
— Active, and the estimated value is isolated and does not affect any other
features.
Cell capacity represents an estimated traffic rate when all available resources are
supposed to be fully used in the cell. The cell capacity is calculated from the
average bit rate divided by average degree of usage, where the degree of usage
indicates how many PRBs are used amongst the available PRBs. There are three
parameters, BitRate, UsedPRBs, and AvailablePRBs, and they are periodically
L0001976A
feature. The boundary value can be modified after the feature is activated. For
more information, see Boundary Configuration on page 9.
Start
Collect data
yes yes
yes yes
Reset counters
L0001977B
The complete transition period is set to 15 minutes, and the time for each
transition step is set to 1 minute.
dynCellSubscrCapnew
Cell capacity [kbps]
Transition period
New estimated
cell capacity
dynCellSubscrCapold
Transition step
Time [min]
New cell capacity is estimated
L0001978A
— Parameter qciSubscriptionQuanta
4 Parameters
— EUtranCellFDD.dynCellSubscrCap
— EUtranCellTDD.dynCellSubscrCap
cellCapMaxCellSubCap Maximum value for the estimated cell capacity.
Exists for MO classes:
— EUtranCellFDD.cellCapMaxCellSubCap
— EUtranCellTDD.cellCapMaxCellSubCap
cellCapMinCellSubCap Minimum value for the estimated cell capacity.
Exists for MO classes:
— EUtranCellFDD.cellCapMinCellSubCap
— EUtranCellTDD.cellCapMinCellSubCap
cellCapMinMaxWriProt Write protection that prevents the feature Automated Cell Capacity
Estimation from changing the value on parameters
cellCapMinCellSubCap and cellCapMaxCellSubCap.
Exists for MO classes:
— EUtranCellFDD.cellCapMinMaxWriProt
— EUtranCellFDD.cellCapMinMaxWriProt
useEstimatedCellCap Switches on the use of estimated cell capacity in load management
features. Exists in MO class
AutoCellCapEstFunction.useEstimatedCellCap.
Parameter Description
— EUtranCellFDD.cellSubscriptionCapacity
— EUtranCellTDD.cellSubscriptionCapacity
qciSubscriptionQuanta (Operator The unit of the value must be identical to kbps instead of in
Defined) proportion to kbps
qciSubscriptionQuanta (Predefined) The unit of the value must be identical to kbps instead of in
proportion to kbps
— EUtranCellFDD.cellSubscriptionCapacity
— EUtranCellTDD.cellSubscriptionCapacity
5 Network Impact
6 Performance
6.1 KPIs
This feature has no associated Key Performance Indicators (KPIs).
6.2 Counters
This feature has no directly associated counters.
6.3 Events
Table 6 lists the events associated with the Automated Cell Capacity Estimation
feature.
Table 6 Events
Event Event Parameter Description
INTERNAL_EVENT_CELL_DL_C EVENT_PARAM_ESTIM_CELL_CAPACITY New estimate of cell capacity value.
APACITY
EVENT_PARAM_CELL_CAPACITY_UPDAT The reason for updating cell capacity
E_CAUSE value, normal update or rapid
compensation.
For a full list with detailed information about PM events, see the list files in the
List Files library folder.
Prerequisites
— Continuous Cell Trace Recording (CCTR) is activated since at least one week.
This ensures there is troubleshooting data available if something goes
wrong.
Steps
Prerequisites
Continuous Cell Trace Recording (CCTR) is activated since at least one week. This
ensures there is troubleshooting data available if something goes wrong.
Steps