Professional Documents
Culture Documents
INLET COVERS
MODELS - see page 6
E60 Model CH60 E60 A C 2 140/40
E100 Model CH100
THREADS
Threads See table on page 17
A 4 ways, closed center
OUTLET COVERS
MODEL - see page 7
S60 Model CH60 S60 A 2
S100 Model CH100
THREADS
Threads See code table page 17
Standard
3
MODELS
4
GENERAL DATA
SPECIFICATIONS
CH60 maximum flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 LPM (15 GPM)
CH100 maximum flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 LPM (25 GPM)
Work pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 BAR (3500 PSI)
Maximum pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 BAR (4250 PSI)
Maximum pressure in outlet section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 BAR (570 PSI)
Temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40ºC +80ºC (-40ºF +176ºF)
Fluid recommendation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mineral hydraulic oil
Fluid viscosity recommended . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26-55 cSt
CIRCUIT TYPES
5
INLET COVERS
E60
A Top inlet port (standard)
B Side inlet port (optional)
D Top inlet and outlet
B 25,4
P T
C
25,4 17 11
E100 67 max.
29
6
OUTLET COVERS
S60
A Top outlet port (standard) C
Pressure
T
C I
By-pass
B Side outlet port (optional) Outlet
P
T
H Plug on the top I
Pressure
By-pass 30
P
Outlet
T
D
Pressure
By-pass
Outlet
25
T
E
Pressure E J
By-pass
S100 Outlet
T
A Top outlet port (standard) J
Pressure
By-pass
H Plug on the top Outlet
30
T
F
Pressure
F L
By-pass
P
Outlet
T
L
Pressure
By-pass CH100 30,5
P
Outlet CH60 32
G
Pressure
By-pass
T
Outlet
CH100 30,5
B Side outlet port (optional) CH60 32
7
SPOOL TYPES
A B
A B
A B
4 ways closed center
C "A" plugged
P T
A B
4 ways closed center
D "B" plugged
P T
A B
3 ways closed center
E "A" plugged
CENTRAL BODY FOR SUPPORTING P T
VALVES
A B
3 ways closed center
F "B" plugged
P T
A B
4 ways open center
G "A" plugged
P T
A B
4 ways open center
H "B" plugged
P T
A B
Float spool in
I (inner invertor)
P T
A B
Float spool out
J (outer invertor)
P T
8
AUXILIARY VALVES
T P B 25,4 17 11
67 max.
See Notes
C 25,4
47
D 25,4
16
E 25,4 22,2
17
62 max.
See Notes
F 25,4
12
G 25,4 17 11
70 max.
Note: Valves “B”, “E” and “G” may not be used
with electrical drive. See Notes
9
TYPES OF DRIVE
6.4
8.4
M8 x 1.25
CH100
CH60
CH60 - M8 x 1.25
CH100 - M10 x 1.5 F
ø8
8.3
M ø8
1/8" NPT
(2x)
60 CH100
L Hydraulic 56 CH60
7/16" UNF
Minimum Pressure: 8 bar SAE # 4 (2x)
Maximum Pressure: 100 bar
10
TYPES OF DRIVE
6
Ø
26
280
7
7 50
30º 30º
395
157
48
Ø 70
40 118,5
50
97
I Mechanical Joystick
325
15º
15º
J Electrical
83 (Ref.) 117 (Ref.) DIN 43650
12 VCC 12 VCC
96 (Ref.)
90 (Ref.)
24 VCC 24 VCC
1,5 m
11
CENTERED TYPES
CH100 40 CH100 40
CH60 32 CH60 32
CH100 73 CH100 96
CH60 56 CH60 92
12
CENTERED TYPES
Ø8
8.4
6.4
F
CH100
CH60
20.5
Ø8
M
8.3
20
13
CH60 DIMENSIONS
Y 120
38 24 38 56
74*
119
32
82
14
18 18 98
0
X-6
* Only “D” and “E” valves
Number of
X Y
sections
A A 1 72 112
T 2 108 148
3 144 184
4 180 220
28,5
5 216 256
P 6 252 292
B B
26
7 288 328
Torque 13 ft lbs
8 324 364
9 360 400
r. 4,5 10 396 436
11 432 472
13 12 468 508
36
A A T
P B B
A A T
P B B
14
CH100 DIMENSIONS
Y 152
46 30 46 82
142
38
100
25 25
15
127
X
10
r. 5,5 Number of
X Y
sections
A A 1 95 137
2 139 181
3 184 226
4 229 270
Torque 20 ft lbs 5 273 314
6 318 359
P B B T
7 362 403
8 406 448
9 451 492
10 495 537
11 540 581
12 584 626
44,5
A A
P B B T
A A
P B B T
15
PRESSURE DROP (P T)
CH60 CH100
17
12 Work sections
16 16
11 Work sections
15 12 Work sections 15
10 Work sections
14 11 Work sections 14
9 Work sections
13 10 Work sections 13
8 Work sections
12 9 Work sections 12
8 Work sections 7 Work sections
11 11
6 Work sections
10 7 Work sections 10
5 Work sections
Pressure (bar)
8 8 4 Work sections
5 Work sections
7 7
4 Work sections
6 6 3 Work sections
5 3 Work sections 5
3 1 Work sections 3
1 Work sections
2 2
1 1
0 10 20 30 40 50 60 0 10 20 30 40 50 60 70 80 90 100
Flow (l/min.) Flow (l/min.)
16
TABLES
Specify
CH60
Section
Inlet
Model
Outlet
CH100
Section
Standard Available
G FLEXIBLE CABLE FOR SPOOL CONTROL LEVER
A B C
Options Without lock Lock in "A" and/or "B" Lock in central position
Standard cables 100 - 125 - 150 - 175 - 200 - 250 - 275 - 300 - 325 - 350 - 400 - 450 - 500 cm (other: consult)
Ex. how to order A60 - 1AG2A1 - AB - A100 - 140/40
17
WORK SECTION - ORDER CODE
MODEL
A60 Supporting valves for body - CH60
A60 1 A E 2 A 1 A B 140/40
B60 Normal body - CH60 (no valves)
A100 Supporting valves for body - CH100
B100 Normal body - CH100 (no valves)
CIRCUIT TYPES - see page 5
1 Parallel (no priority)
2 Tandem (priority)
3 Series (no priority)
SPOOL TYPES - see page 8
A 4 ways, closed center
B 4 ways, open center
C 4 ways, closed center - "A" plugged
D 4 ways, closed center - "B" plugged
E 3 ways, closed center - "A" plugged
F 3 ways, closed center - "B" plugged
G 4 ways, open center - "A" plugged
H 4 ways, open center - "B" plugged
I Float-spool in (Use "J" centering type)
J Float-spool out (Use "J" centering type)
SPOOL CONTROLS - see page 10 and 11
A No extension ("spool control side" and "centered type" not applied)
B Extension and female bearing
C Extension and tap bearing
D With support and without lever
E With lever
F Pneumatic (use "A" in centering type)
G Cable with lever (see page 17)
H Cable with Joystick (see page 17) (the following body use "A")
I With Joystick (the following body use "A")
J Electrical (see page 17)
L Hydraulic
SPOOL CONTROL SIDE - see page 14 and 15
1 Drive side "A"
2 Drive side "B"
3 Electrical "A" and "B" (use "L" centering type)
CENTERED TYPE - see page 12 and 13
* A By string
B Detent in 3 positions
C By detent spring in "A"
D By detent spring in "B"
E By detent spring in "A" and "B"
* F By spring with hydraulic unlock
* G By spring with adjustment
* H By spring with female extension
* I By spring with male extension
J By spring for flotation
L By spring for electrical command
* Available for electrical command with side drive
THREAD
Thread See table page 17
AUXILIARY VALVES - see page 9
A Plug
B Direct relief with external adjustment (except electrical drive) Socket side “A”
C Direct relief with internal adjustment
D Piloted retaining
E Flow control valve (except electrical drive)
F Anticavitation Socket side “B”
Direct relief with anticavitation and external adjustment
G
(except electrical drive)
H Plastic plug
For valves "B", "C" and "G" specify pressure and flow
Exemple: B (140/40)
Pressure 140 bar with flow 40 l/min. Standard
18