You are on page 1of 18

INDEX

How to require inlet covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3


How to require outlet covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
General data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Circuit types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Inlet covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Outlet covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Spool types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Auxiliary valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Types of drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10/11
Centered types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12/13
CH60 dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
CH100 dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Pressure drop (P-T) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Auxiliary valves - compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Threads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Flexible cable for spool control lever . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Flexible cable & controls for Joystick . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Electrical spool control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Work section - order code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
HOW TO ORDER

INLET COVERS
MODELS - see page 6
E60 Model CH60 E60 A C 2 140/40
E100 Model CH100

PORTS - see page 6


A Top port
B Side port, top port plugged
C Top port, with side gauge port (1/4" NPT)
D Top inlet and outlet ports (use H, I, J and L on outlet)

MAIN RELIEF VALVES - see page 6


A No valve, with plastic plug
B No valve, with special plug
C With direct valve and external adjustment
D With direct valve and internal adjustment

THREADS
Threads See table on page 17
A 4 ways, closed center

OUTLET COVERS
MODEL - see page 7
S60 Model CH60 S60 A 2
S100 Model CH100

PORTS - see page 7


A Top port
B Side port (top plugged)
C Side port for power beyond (top to tank)
D Top port (with closed bypass)
E Top port (for electrical control)
F Top port (for electrical control, with power beyond)
G Side port (for electrical control, top plugged)
H Top plugged
I Top plugged, with power beyond
J Top plugged for electrical control
L Top plugged for electrical control, with power beyond

THREADS
Threads See code table page 17

Standard

3
MODELS

CH60 - 60 LPM (15 GPM)

With cable spool control

CH100 - 100 LPM (25 GPM)

With electrical spool control

4
GENERAL DATA

SPECIFICATIONS
CH60 maximum flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 LPM (15 GPM)
CH100 maximum flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 LPM (25 GPM)
Work pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 BAR (3500 PSI)
Maximum pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 BAR (4250 PSI)
Maximum pressure in outlet section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 BAR (570 PSI)
Temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -40ºC +80ºC (-40ºF +176ºF)
Fluid recommendation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mineral hydraulic oil
Fluid viscosity recommended . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26-55 cSt

CIRCUIT TYPES

PARALLEL CIRCUIT (no priority)


Two or more bodies are operated simultaneously, the fluid always shall feed the less pressure.
P A B A B T

Inlet Work sections Outlet

TANDEM CIRCUIT (priority)


The fluid feeds just the operated body which is closed to the inlet and do not allow the use of others.
P A B A B T

Inlet Work sections Outlet

SERIES CIRCUIT (no priority)


Two or more sections are simultaneously activated, the flow returns from the first section and feeds the second one.
T P A B A B T

Inlet and Outlet Work Sections Outlet

5
INLET COVERS

E60
A Top inlet port (standard)
B Side inlet port (optional)
D Top inlet and outlet

B 25,4

P T

C Pressure test port (1/4” NPT)


11

C
25,4 17 11

E100 67 max.

A Top inlet port (standard) D 25,4


B Side inlet port (optional)
D Top inlet and outlet

29

C Pressure test port (1/4” NPT)

6
OUTLET COVERS

S60
A Top outlet port (standard) C
Pressure
T
C I
By-pass
B Side outlet port (optional) Outlet
P

T
H Plug on the top I
Pressure
By-pass 30
P
Outlet

T
D
Pressure
By-pass
Outlet

25

T
E
Pressure E J
By-pass
S100 Outlet

T
A Top outlet port (standard) J
Pressure
By-pass
H Plug on the top Outlet
30

T
F
Pressure
F L
By-pass
P
Outlet

T
L
Pressure
By-pass CH100 30,5
P
Outlet CH60 32

G
Pressure
By-pass
T
Outlet
CH100 30,5
B Side outlet port (optional) CH60 32

7
SPOOL TYPES

NORMAL CENTRAL BODY

Ref.: Description Symbol

A B

A 4 ways closed center


P T

A B

B 4 ways opened center


P T

A B
4 ways closed center
C "A" plugged
P T

A B
4 ways closed center
D "B" plugged
P T

A B
3 ways closed center
E "A" plugged
CENTRAL BODY FOR SUPPORTING P T
VALVES
A B
3 ways closed center
F "B" plugged
P T

A B
4 ways open center
G "A" plugged
P T

A B
4 ways open center
H "B" plugged
P T

A B
Float spool in
I (inner invertor)
P T

A B
Float spool out
J (outer invertor)
P T

8
AUXILIARY VALVES

WORK SECTION CH60AND CH100


11 11 10
A A A

25,4 25,4 25,4

For 3 ways spools. For valves B, C, F and G. For valves D and E.

T P B 25,4 17 11

67 max.
See Notes

C 25,4

47

D 25,4

16

E 25,4 22,2
17

62 max.
See Notes

F 25,4

12

G 25,4 17 11

70 max.
Note: Valves “B”, “E” and “G” may not be used
with electrical drive. See Notes

9
TYPES OF DRIVE

A Without spool end B Female spool end


CH100 8 CH100 34
CH60 6.5 CH60 30

6.4
8.4
M8 x 1.25

CH100
CH60
CH60 - M8 x 1.25
CH100 - M10 x 1.5 F
ø8

C Male spool end D With support


CH100 34 CH100 70
CH60 30 CH60 66
M10 x 1,5

8.3
M ø8

E With lever 113


F Pneumatic
15º
15º
50
213

1/8" NPT
(2x)

Minimum Pressure: 4 bar


Maximum Pressure: 12 bar

60 CH100
L Hydraulic 56 CH60

7/16" UNF
Minimum Pressure: 8 bar SAE # 4 (2x)
Maximum Pressure: 100 bar

10
TYPES OF DRIVE

G Cable with lever H Cable with joystick


HE HD HC HB HA

6
Ø

26

280
7
7 50

30º 30º

395
157

48
Ø 70
40 118,5
50
97

I Mechanical Joystick
325
15º
15º

J Electrical
83 (Ref.) 117 (Ref.) DIN 43650

12 VCC 12 VCC
96 (Ref.)
90 (Ref.)

24 VCC 24 VCC
1,5 m

11
CENTERED TYPES

A Centered spring B 3 detent positions

CH100 40 CH100 40
CH60 32 CH60 32

C Spring, detent in “A” D Spring, detent in “B”


CH100 73 CH100 73
CH60 56 CH60 56

Spring, detent in “A” and “B”


E Spring, detent in “A” and “B” F with hydraulic release

CH100 73 CH100 96
CH60 56 CH60 92

12
CENTERED TYPES

G Spring with adjustable stroke


CH100 81
CH60 70

H Spring with female ext. for double control


_5
+
CH100 93
_5
+
CH60 88

Ø8
8.4
6.4

F
CH100
CH60

20.5

I Spring with male ext. for double control


_5
+
CH100 93
_5
+
CH60 88

Ø8

M
8.3

20

J Spring for float


Spool control in Spool control out

CH100 78 CH100 12.5 CH100 101


CH60 65 CH60 10 CH60 82

13
CH60 DIMENSIONS

Y 120

38 24 38 56
74*

119
32

82

14
18 18 98
0
X-6
* Only “D” and “E” valves

Number of
X Y
sections
A A 1 72 112
T 2 108 148
3 144 184
4 180 220

28,5
5 216 256
P 6 252 292
B B
26

7 288 328
Torque 13 ft lbs
8 324 364
9 360 400
r. 4,5 10 396 436
11 432 472
13 12 468 508

36

Side “A” spool control Side “B” spool control

A A T

P B B

A A T

P B B

14
CH100 DIMENSIONS

Y 152

46 30 46 82

142
38

100
25 25

15
127
X

10

r. 5,5 Number of
X Y
sections
A A 1 95 137
2 139 181
3 184 226
4 229 270
Torque 20 ft lbs 5 273 314
6 318 359
P B B T
7 362 403
8 406 448
9 451 492
10 495 537
11 540 581
12 584 626

44,5

Side “A” spool control Side “B” spool control

A A

P B B T
A A

P B B T

15
PRESSURE DROP (P T)

CH60 CH100
17
12 Work sections
16 16
11 Work sections
15 12 Work sections 15
10 Work sections
14 11 Work sections 14
9 Work sections
13 10 Work sections 13
8 Work sections
12 9 Work sections 12
8 Work sections 7 Work sections
11 11
6 Work sections
10 7 Work sections 10
5 Work sections
Pressure (bar)

9 6 Work sections Pressure (bar) 9

8 8 4 Work sections
5 Work sections
7 7
4 Work sections
6 6 3 Work sections

5 3 Work sections 5

4 2 Work sections 4 2 Work sections

3 1 Work sections 3
1 Work sections
2 2

1 1

0 10 20 30 40 50 60 0 10 20 30 40 50 60 70 80 90 100
Flow (l/min.) Flow (l/min.)

Oil viscosity: 32 cSt

16
TABLES

AUXILIARY VALVES - COMPATIBILITY - see page 9


A B C D E F G
A
B
C
D
E Compatible
F
G Not Compatible
THREADS
Code 1 2 3 4 5 6 7 8 9 X
SAE Nº BSP - Parallel Metric - ISO 6149
Threads #8 #10 #12 Others
3/8"-19 1/2"-14 3/4"-14 M18x1,5 M22x1,5 M27x2
3/4"-16 UNF 7/8"-14 UNF 1.1/16-12 UN
Inlet
Model
Outlet

Specify
CH60
Section
Inlet
Model
Outlet
CH100
Section
Standard Available
G FLEXIBLE CABLE FOR SPOOL CONTROL LEVER
A B C
Options Without lock Lock in "A" and/or "B" Lock in central position
Standard cables 100 - 125 - 150 - 175 - 200 - 250 - 275 - 300 - 325 - 350 - 400 - 450 - 500 cm (other: consult)
Ex. how to order A60 - 1AG2A1 - AB - A100 - 140/40

H FLEXIBLE CABLE & CONTROLS FOR JOYSTICK


A B C D E
Two On-Off-On
On-Off On-Off-On Two On-Off-On
Options Without switches switches and one
switch switch switches
On-Off switch
Standard cables 100 - 125 - 150 - 175 - 200 - 250 - 275 - 300 - 325 - 350 - 400 - 450 - 500 cm (other: consult)
Ex. how to order A60 - 1AH2A1 - AB - A100 - 140/40

J ELECTRICAL SPOOL CONTROL


Voltage A 12 VCC B 24 VC C E 12 VCC - DIN 43650 F 24 VCC - DIN 43650
Ex. how to order A60 - 1AJ3L1 - AC - A - 140/40
Voltage Amperage (A) Resistance (Ω)
12 VCC 1,75 6,85
24 VCC 0,88 27
Power: 21W

17
WORK SECTION - ORDER CODE

MODEL
A60 Supporting valves for body - CH60
A60 1 A E 2 A 1 A B 140/40
B60 Normal body - CH60 (no valves)
A100 Supporting valves for body - CH100
B100 Normal body - CH100 (no valves)
CIRCUIT TYPES - see page 5
1 Parallel (no priority)
2 Tandem (priority)
3 Series (no priority)
SPOOL TYPES - see page 8
A 4 ways, closed center
B 4 ways, open center
C 4 ways, closed center - "A" plugged
D 4 ways, closed center - "B" plugged
E 3 ways, closed center - "A" plugged
F 3 ways, closed center - "B" plugged
G 4 ways, open center - "A" plugged
H 4 ways, open center - "B" plugged
I Float-spool in (Use "J" centering type)
J Float-spool out (Use "J" centering type)
SPOOL CONTROLS - see page 10 and 11
A No extension ("spool control side" and "centered type" not applied)
B Extension and female bearing
C Extension and tap bearing
D With support and without lever
E With lever
F Pneumatic (use "A" in centering type)
G Cable with lever (see page 17)
H Cable with Joystick (see page 17) (the following body use "A")
I With Joystick (the following body use "A")
J Electrical (see page 17)
L Hydraulic
SPOOL CONTROL SIDE - see page 14 and 15
1 Drive side "A"
2 Drive side "B"
3 Electrical "A" and "B" (use "L" centering type)
CENTERED TYPE - see page 12 and 13
* A By string
B Detent in 3 positions
C By detent spring in "A"
D By detent spring in "B"
E By detent spring in "A" and "B"
* F By spring with hydraulic unlock
* G By spring with adjustment
* H By spring with female extension
* I By spring with male extension
J By spring for flotation
L By spring for electrical command
* Available for electrical command with side drive
THREAD
Thread See table page 17
AUXILIARY VALVES - see page 9
A Plug
B Direct relief with external adjustment (except electrical drive) Socket side “A”
C Direct relief with internal adjustment
D Piloted retaining
E Flow control valve (except electrical drive)
F Anticavitation Socket side “B”
Direct relief with anticavitation and external adjustment
G
(except electrical drive)
H Plastic plug
For valves "B", "C" and "G" specify pressure and flow
Exemple: B (140/40)
Pressure 140 bar with flow 40 l/min. Standard

18