Ord. code
AutoConfiguration Adapter
943 271-001
ACA 21-M12
Ord. code
943 913-001
ACA 21-USB (EEC)
Ord. code
943 271-002
ACA 21-M12 (EEC)
Ord. code
943 913-002

The AutoConfiguration Adapters ACA 21-... are devices for storing and updating configuration data
and software for the Hirschmann Industrial ETHERNET devices 1).
In the case of a device failure, the ACA 21-... enables a very simple configuration data transfer by
means of a substitute device of the same type.

Storing the current configuration data in the ACA 21-...


You can transfer the current device configuration onto the ACA 21-... and simultaneously onto the
flash memory of the device using the Web-based Interface (Menu „Load/Save“) or using the
Command Line Interface.

Transferring the configuration data from the ACA 21-...


When you restart, the device assumes the configuration data of the ACA 21-... and saves them
permanently into the flash memory.

Updating software
See User Manual Basic Configuration “Loading the Software from the ACA“ for this.

1) TheACA support of your device you can learn from the Read-me file on the product CD or in the
Internet on the product page.

Hirschmann. Simply a good Connection.


Installing the ACA 21-...
Plug the ACA 21-... into the USB terminal or the M12 terminal of the device.
Note: When you restart, the device always assumes the configuration data of the ACA and saves
them permanently into the flash memory. Wether the configuration data of the ACA coincides with
the configuration data of the device, shows you the status of the AutoConfiguration Adapter in the
Web-based Interface or Command Line Interface.

1 2 3 4 1 U in 1 U in
2 - Data 2 n.c.
3 + Data 4 3 3 - Data
4 Ground 1 5 2 4 Ground (Gnd)
(Gnd) 5 + Data

USB Plug Pinout M12 Plug Pinout

Notes:
- The ACA 21-... is intended for use and connection only to Hirschmann Industrial ETHERNET
products providing Limited Power Source according to NEC class 2 requirements.
Maximum Electrical Ratings: Uin: + 5 VDC, Iin: 100 mA.
- The ACA 21-... is intended for use without an additonal extension-cable.
- Peripheral equipment must be suitable for the location it is used in.

Relevant Information for North America:


Additional Information for Use in Hazardous Locations (North America):
This product may be operated in hazardous locations only if the product label is marked accor-
dingly. The following information applies when operating this equipment in hazardous locations:
INDUSTRIAL CONTROL EQUIPMENT FOR USE IN HAZARDOUS LOCATIONS.
CLASS I, DIVISION 2, Groups A, B, C and D; TEMPERATURE CODE and AMBIENT TEMPERA-
TURE as labelled on the product.
WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER
HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON - HAZARDOUS.
TO BE SUPPLIED BY A CLASS 2 POWER SUPPLY OR ISOLATED LOW VOLTAGE LIMITED
ENERGY (LVLE).

Relevant Information for Europe (EU):


This product may be operated in EX zone 2 only if the product label is marked as follows:
II 3G. Further parameters, relevant for the explosion protection can be learned from the
product label.
The ACA 21-... modules must be installed in a suitable ATEX certified IP54 enclosure - tested
to 4 J impact due to low risk of mechanical danger.

Hirschmann Automation and Control GmbH


Stuttgarter Strasse 45 - 51
72654 Neckartenzlingen
Germany/Allemagne
Tel.: +49 / 1805/ 14-1538
Fax: +49 / 7127/ 14-1551
E-Mail: hac-support@hirschmann.de
Internet: http://www.hirschmann-ac.com

039 518-002-01-0208
Printed in Germany