RIZAL TECHNOLOGICAL UNIVERSITY
Boni Avenue, Mandaluyong City
College of Engineering, Architecture, and Technology
CIVIL ENGINEERING DEPARTMENT
CE11 BUILDING SYSTEMS DESIGN
Assignment/Project No. _ 2.
STANDARD LIST
DATE PERFORMED: NAME:
| Oct. 4, 2024 MARASIGAN » KYLA G.
DATE SUBMITTED: STUDENT NO.:
OGOT. 11 2024 2019 - 101395
‘GROUP NO. ‘SECTION:
GROUP 7 CEIT - 02 -501P.
OF. 201 |. CONCEPCION
PROFESSORLECTURE ASSIGNMENT # 2
5 STANDARD LIST OF ELECTRICAL CODES
FOR CONSTRUCTION
NFPA II|-STANDARD ON STORED ELECTRICAL ENERGY
EMERCENCY AND STANDBY POWER SYSTEMS.
SCOPE LA
THS STANDARD COVERS PERFORMANCE REQUIREMENTS
FOR STORED ELECTRICAL ENERGY SYSTEMS PROVIDING AN AL
TERNATE SOURCE OF ELECTRICAL POWER IN BUILDINGS AND
FACILITIES IN THE EVENT THAT THE NORMAL ELECTRICAL
POWER SOURCE FAILS.
ALLL
FOR EMERGENCY POWER SYSTEMS SUPPED BY EMERGENCY
GENERATORS
142
SYSTEMS COVERED IN THIS STANDARD SHALL INCLUDE POWER
SOURCES , TRANSFER EQUIPMENT, CONTROLS , SUPERVISORY
EQUIPMENT, AND ACCESSORY EQUIPMENT, INCLUDING INTEGRAL
ACCESSORY EQWIPMENT NEEDED TO SUPPLY ELECTRICAL PO-
WER TO THE SELECTED CIRCUITS.
113
THIS STANDARD SHALL COVER INSTALLATION, MAINTENANCE,
OPERATION , AND TESTING REQUIREMENTS AS THEY PERTAIN
TO THE PERFORMANCE OF THE STORED EMERGENCY POWER
SUPPLY SYSTEM (SEPSS)
4.
THIS STANDARD SHALL NOT COVER THE FOLLOWING:
Q APPLICATION OF THE SEPPS (2) DISTRIBUTION WIRING
3) SYSTEMS HAVING TOTAL OUTPUTS LESS THAN 500 VA OR
LESS THAN 94 V, OR SYSTEMS LESS THAN CLASS 0.083 (A)UNIT
REQUIREMENT (5) NUCLEAR SOURCES , SOLAR SYSTEMS, ANDWIND STORED-ENERGY SYSTEMS (¢) UNINTERRUPTIBLE POWER
SYSTEMS (URS) SUPPLIED BY AN EMERGENCY POWER SUPPLY
SYSTEM (PSS) 1.1.42 THE FOLLOWING SHALL NOT @E WITHIN
THE SCOPE OF THIS STANDARD :(4) SPECIFIC BUILDINGS OR FA-
CILITIES , OR BOTH, REQUIRING AN SEPSS (2) SPECIFIC LOADS 10
BE SERVED BY THE SEPPS (3) TYPE, CLASS, OR LEVEL TO BE
ASSIGNED TO ANY SPECIFIC. LOAD.
NFPA 70B - RECOMMENDED PRACTICE
FOR ELECTRICAL EQUIPMENT MAINTENANCE
44. SCOPE
414.
THIS RECCOMMENOED PRACTICE APPLIES TO PREVENTIVE
MAINTENANCE FOR ELECTRICAL , ELECTRONIC , AND COMMUNI-
CKTION SYSTEMS AND EQUIPMENT AND IS NOT INTENDED 10
DUPLICATE OR SUPERSEDE INSTRUCTIONS THAT MANUPACTU-
RERS NORMALLY PROVIDE. SYSTEMS AND EQUIPMENT COVERED
ARE TYPICAL OF THOSE INSTALLED IN INDUSTRIAL. PLANTS,
INSTITUTIONAL AND COMMERCIAL BUILDINGS , AND LARGE MUL-
TIFAMILY RESIDENTIAL COMPLEXES
442
CONSUMER APPLIANCES AND EQUIPMENT [NTENDED PRIMARILY
FOR USE IN THE HOME ARE NOT INCLUDED.
NFPA 70E - STANDARD FOR ELECTRICAL SAFETY IN
THE WORKPLACE
THIS STANDARD ADDRESSES ELECTRICAL SAFETY -RELATED
WORK PRACTICES, SAFETY- RELATED MAINTENANCE REGUIRE-
MENTS, AND OTHER AOMINISTRATIVE CONTROLS FOR EMPLOYEE
WORKPLACES THAT ARE NECESCARY FOR THE PRACTICAL
SAFEGUARDING OF EMPLOYEES RELATIVE TO THE HAZARDS
ASSOCIATED WITH ELECTRICAL ENERGY DURING ACTIVITIESSUCH AS THE INSTALLATION , INSPECTION , OPERATION, MAIN~-
TENANCE, AND DEMOLITION OF ELECTRIC. CONDUCTORS , ELEC-
TRIC EGUIPMENT, SIGNALING AND COMMUNICATIONS CONDUC-
TORS AND EQUIPMENT, AND RACEWAYS.
THIS STANDARD ALSO INCLUDES SAFE WORK PRACTICES FORK
EMPLOYEES PERFORMING OTHER WORK ACTIVITIES THAT CAN
EXPOSE THEM TO ELECTRICAL HAZARDS AS WELL AS SAFE
WORK PRACTICES FOR THE FOLLOWING:
(INSTALLATION OF CONDUCTORS AND FGUIPMENT THAT CON-
NEGT TO THE SUPPLY OF ELECTRICITY
(QINSTALLATIONS USED @Y THE ELECTRIC UTILITY, SUCH AS
OFFIGE BUILDINGS , WAREHOUSES, GARAGES, MACHINE SHOPS,
AND RECREATIONAL BUILDINGS THAT ARE NOT AN INTEGRAL
PART OF A GENERATING PLANT, OR CONTROL CENTER:
NFPA 110 - STANDARD FOR EMERGENCY AND STANDBY
POWER SYSTEMS
41 SCOPE
THS STANDARD CONTAINS REQUIREMENTS COVERING THE
PERFORMANCE OF EMERGENCY AND STANDBY POWER SYSTEMS
PROVIDING AN ALTERNATE SOURCE OF ELECTRICAL POWER
TO LOADS IN BUILDINGS AND FACILITIES IN THE EVENT THAT
THE PRIMARY POWER SOURCE FAILS.
144
POWER SYSTEMS COVERED IN THIS STANDARD INCLUDE PO-
WER SOURCES, TRANSFER &G.UIPMENT, CONTROLS , SUPERVISORY
EQUIPMENT, AND ALL RELATED ELECTAICAL AND MECHANI-
CAL AUXILIARY AND ACCESSORY EQUIPMENT NEEDED 10
SUPPLY ELECTRICAL POWER TO LOAD TERMINALS OF THE
TRANSFER EQUIPMENT.
Le.
THIS STANDARD COVERS INSTALLATION , MAINTENANCE , OPE -RATION , AND TESTING REQUIREMENTS AS THEY PERTAIN TO
PERFORMANCE OF THE EMERGENCY POWER SUPPLY SYSTEM
(EPSS)
Lg
THIS STANDARD DOES NOT COVER THE FOLLOWING:
(D APPLICATION OF THE £PSS
(@ EMERGENCY LIGHTING UNIT EQUIPMENT
@ DISTRIOUTION WIRING
@UTILITY SERVICE WHEN SUCH SERVICE IS PERMITTED AS
THE ESS
()PARAMETERS FOR STORED ENERGY DEVICES
(THE EQUIPMENT OF SYSTEMS THAT ARE NOT CLASSED As
LEVEL 1 OR LEVEL 2 SYSTEMS IN ACCORDANCE WITH
CHAPTER 4 OF THIS STANDARD
44
THIS STANDARD DOES NOT ESTABLISH CRITERIA FOR STORED
ENERGY SYSTEMS
115
THE SELECTION OF ANY OF THE FOLLOWING IS NOT WITHIN
THE SOOPE OF THIS STANDARD
(DSPEGIFIC BUILDINGS OR FACILITIES OR BOTH, REQUIRING
AN EPS
(2) SPECIFIC LOADS TO BE SERVED BY THE RSS
(*Y* ASSIGNMENT OF TYPE , CLASS, OR LEVEL TO ANY SPECI-
FIC LOAD
NFPA 76 -GUIDE ON ELECTRICAL INSPECTIONS
THIS DOCUMENT COVERS MINIMUM CRITERIA TO AID IN ORGA-
NIZING AND CONDUCTING ELECTRICAL INSPECTIONS , WHICH
INCLUDES ADMINISTRATION , PLANS REVIEW, AND FIELD
INSPECTION , FOR NEW ELECTRICAL INSTALLATIONS ANDMODIFICATIONS TO EXISTING ELECTRICAL INSTALLATIONS IN
CONFORMANCE WITH AHJ REQUIREMENTS.
REFERENCE:
Notional Fire Protection Association, (024). Electrical Codes and Standards.
Retrieved on November 9, 2024 From lnttps://aww. nfpa. ory/NEC/ctectrical~